| 1 | 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq. mm. FRLS PVC insulated copper conductor single core cable etc. as required. (GROUP-B) | BI01010001010000000000000515BI0100001113 | 77 | Point |
| 2 | 2 | Wiring for circuit/ submain wiring alongwith earth wire the following sizes FRLS PVC insulated copper conductor, single core cable in surface/ recess medium class PVC conduit as required. A) 2 x 1.5 sq. mm + 1 x 1.5 sq. mm | | 200 | Metre |
| 3 | 3 | Wiring for circuit/ submain wiring alongwith earth wire the following sizes FRLS PVC insulated copper conductor, single core cable in surface/ recess medium class PVC conduit as required. A) 2 x 4 sq. mm + 1 x 4 sq. mm | | 185 | Metre |
| 4 | 4 | Supplying and fixing metal box of 150 mm X 75 mm X 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover infront of including providing and fixing 3 pin 5/6 amp socket outlet and 5/6 amp piano type switch, connection, painting etc .as required. | | 11 | Each |
| 5 | 5 | Supplying and fixing metal box of 180 mm X 100 mm X 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 A & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required. | | 15 | Each |
| 6 | 6 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. (a) 200 mm X 300 mm X 60 mm deep (For loose wire box) | | 5 | Each |
| 7 | 7 | Providing and fixing circular/ Hexagonal GI box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick GI sheet with its top surface hacked for proper bonding, top lid shall be screwed into the GI box by means of 3.3 mm dia round headed screws, one lock at the corners, clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. | | 10 | Each |
| 8 | 8 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. | | 10 | Each |
| 9 | 9 | Supplying and fixing 3 pin 5 amps Ceiling rose on the existing junction box/ wooden block including connection etc. as required. | | 35 | Each |
| 10 | 10 | Supplying and fixing PVC batten/ angle holder including connections etc. as required. | | 15 | Each |
| 11 | 11 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator) A) 6 way , Double door | | 1 | Each |
| 12 | 12 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator) A) 2+6/ 8 way , Double door | | 1 | Each |
| 13 | 13 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator) A) 2+10/ 12 way, Double door | | 2 | Each |
| 14 | 14 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. A) Single pole | | 30 | Each |
| 15 | 15 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. A) Double pole | | 4 | Each |
| 16 | 16 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required. | | 5 | Each |
| 17 | 17 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation andre-filling as required | | 30 | Metre |
| 18 | 18 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. | | 20 | Metre |
| 19 | 19 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required. | | 8 | Set |
| 20 | 20 | Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. | | 12 | Each |
| 21 | 21 | Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 Nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. | | 6 | Each |
| 22 | 22 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor complete as required. (For horizontal run) | | 130 | Metre |
| 23 | 23 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor complete as required. (For vertical run) | | 20 | Metre |
| 24 | 24 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. | | 40 | Metre |
| 25 | 25 | Providing, laying and fixing 50 mm dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and re-filling etc. as required | | 12 | Metre |
| 26 | 26 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 KV grade as required. A) 3.5 X 35 sq. mm (32 mm) | | 2 | Each |
| 27 | 27 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 KV grade as required. A) 2 X 25 sq. mm (32 mm) | | 6 | Each |
| 28 | 28 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required A) 3 x 1.5 sq. mm . | | 50 | Metre |
| 29 | 29 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in including excavation, sand cushioning, protective covering and refilling the trench etc as required. A) Upto 35 sq. mm | | 400 | Metre |
| 30 | 30 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. A) Upto 35 sq. mm | | 30 | Metre |
| 31 | 31 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. A) Upto 35 sq. mm (clamped with 1mm thick saddle) | | 50 | Metre |
| 32 | 32 | Supply and fixing of PVC loop box of size 200 x 150 x 100 mm for street/security lights and making connection etc. as required. make Sintex/Hensel or as approved by engg in charge, ) | | 12 | Each |
| 33 | 33 | Supplying & making of GI tubular pole of length 3 mtr ( 80 mm dia) mediume class in cement concrete 1:3:6 (1 cement : 3 coarse sand :6 graded stone aggregate 40 mm nominal size) foundation,MS Base plate 300 x 300 x 6 mm thick including excavation and refilling etc as req as per direction of Engg-in-Charge etc as required.Tata/Prkash/Surya/Jindal | | 8 | Each |
| 34 | 34 | Supply, installation, testing and commissioning of 20 watt LED tube fittings prewired for LED tube, complete with all accessories and LED tube directly on ceiling/ wall including connection with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as required. (Photon Ultra LED Tubelight Cat. No. LHLDCLXNUL8X020 Havells or Philips/CG/Bajaj make) | | 14 | Each |
| 35 | 35 | Supply, installation, testing and commissioning of 1200 mm ceiling fan suitable for operation on 230 Volt, 50 Hz including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. (USHA Model Swift/Supra or it's equivalent to Havells/Khaitan/Bajaj make) | | 10 | Each |
| 36 | 36 | Supply and installation 300 mm steel body exhaust fan of double ball bearing light duty motor with protective bird guard and louvers shutters complete with frame in the existing opening, including, making good the damage, connection, testing, commissioning etc. as required. (USHA Model No. Turbo LD Jet Dix or Havells/Khaitan make) | | 6 | Each |
| 37 | 37 | Supply and fixing linear and compact 7 watt LED Mirror light made up of polycarbonate body including connection etc. as required. (LINNET Cat. No. LCL-07-CDL CG or its equivalent to Havells/Bajaj/Philips make) | | 6 | Each |
| 38 | 38 | Supply and fixing of 15 watt white light LED surface mounted downlight with integrated electronic driver in ceiling complete with all accessories including connections etc. as required. (Comet ROUND Cat. No. LHEAAVP7IL1W012 Havells make or it's equivalent to Bajaj/Philips/CG make) | | 8 | Each |
| 39 | 39 | Supply and fixing of 7 watt LED retrofit lamp B-22 holder base with polycarbonate body and aluminium heat sink etc. as required. (Havells or Philips/Bajaj/CG make) | | 15 | Each |
| 40 | 40 | Providing and fixing 2 X 20 watt LED flamproof industrial lighting fixture, IP65 Protection with 2 Nos. 20 watt LED tube including testing, connection etc. complete as required. (FIAMMA II Cat. No. EXTN2LT8-20 CG make or its equivalent to Philips/C&S/Bajaj make) | | 2 | Each |
| 41 | 41 | Providing and fixing 30 watt LED street light luminaire IP66 Protection, heat resistant toughened glass with frame, pressure dia cast aluminium housing, better optics for uniform distribution with the help of 1.0 mtr long 25 mm dia GI pipe B class suitably bent to the require shape with clamp, nuts and bolts including connection with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. (Endura Pearl Plus Cat. No. ENDURAPEARLSL30WLED757SASYTOPCMP Havells make or its equivalent to Philips/CG/Bajaj make) | | 8 | Each |
| 42 | 42 | Supplying and fixing of post-top, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power 25 watt LED light and making connection with1.5 sq. mm FRLS PVC insulated, copper conductor etc. as required. (Havells make item code RUBYPT25WLED757PSYMTOPC or it's equivalent to Philiphs/Bajaj make) | | 8 | Each |
| 43 | 43 | Fabrication, supplying, installation, testing and commissioning of outdoor type electrical feeder pillar of size 1200 mm x 600 mm x 500 mm deep fabricated out of 2.0 mm CRCA sheet with intermediate membes of same material and guage as required. The box should be supported by 500 mm long legs and frame made by 50 mm x 50 mm x 6 mm thick MS angle iron at the base and almirah type single leaf hinged door with locking arrangement, detachable gland plate made of 3 mm thick MS sheet at the bottom, water drip proofing arrangement at the top, air ventilation grooves at sides dust and vermin proof design, earthing studs, 100 Amp 4 Nos. copper strip bus bar having base connector insulation, 100 Amp TPN switch disconnector fuse unit with HRC fuses in sheet steel enclosure, 63 Amp 5 Nos. DP Isolator output inculding connection with single core copper conductor cable, duly painted with power coated paint etc. as required. (CPRI approved) | | 1 | Each |