Repairs Maintenance Of External Elect Incl Lt Oh Lines Ug Cables Lt Poles Street Lights Security Light Perimeter Lights High Mast Lights Lt Panels Incl Apfc Panels Earthing And Connected Works At North Side Of Runway Under Age Em I Of Ge Nw Vasco 8235/E8, VASCO-Goa

Military Engineer Services-MES has published Repairs Maintenance Of External Elect Incl Lt Oh Lines Ug Cables Lt Poles Street Lights Security Light Perimeter Lights High Mast Lights Lt Panels Incl Apfc Panels Earthing And Connected Works At North Side Of Runway Under Age Em I Of Ge Nw Vasco 8235/E8. Submission Date for this Tender is 19-08-2019. Power Factor Panel Tenders in VASCO Goa. Bidders can get complete Tender details and download the document.




Tender Notice

21205556
Repairs Maintenance Of External Elect Incl Lt Oh Lines Ug Cables Lt Poles Street Lights Security Light Perimeter Lights High Mast Lights Lt Panels Incl Apfc Panels Earthing And Connected Works At North Side Of Runway Under Age Em I Of Ge Nw Vasco 8235/E8
Open Tender
Indian
Goa
VASCO
19-08-2019

Tender Details

Repairs Maintenance Of External Elect Incl Lt Oh Lines Ug Cables Lt Poles Street Lights Security Light Perimeter Lights High Mast Lights Lt Panels Incl Apfc Panels Earthing And Connected Works At North Side Of Runway Under Age Em I Of Ge Nw Vasco 8235 / E8

Key Value

Document Fees
INR 500 /-
EMD
INR 88000.0 /-
Tender Value
INR 44 Lakhs /-

BOQ Items

Sl. No. Item Description Item Code / Make Quantity Units
1 1 M & L for repairing the existing LT panel/ Feeder Pilller Box any type or size by taking proper shutdown from power house and disconnecting and re-connecting cables connection both in coming and outgoing using appropriate size of thimbles, making proper welding, drilling for smooth functioning of panel / feeder door, replacement of unserviceable aluminium bus bar of suitable capacity/size as per existing including bakelite insulators, terminals, base plate, necessay nuts, bolts & washers, locking arrangement complete all as specified and directed. \n(Note: Necessary accessories like MCCB/MCB, CT coil, ammeter, voltmeter, indication lamp, selector switch etc shall be measured and paid separately as supply & fixing under respective item) 20 Each Job
2 2 S & F in repair MCCB four pole 63 Amps with breaking capacity 16KA , 415 Volts, thermal & magnetic release including making all incoming/ outgoing connections complete all as specified and directed by Engineer in Charge.\nMake: Legrand/Siemens/Schneider 2 Each
3 3 All as per item Sr. No: 2.00 but 100 Amps with breaking capacity 16 KA. \nMake: Legrand/Siemens/Schneider 3 Each
4 4 All as per item Sr. No: 2.00 but 125 Amps with breaking capacity 16 KA. \nMake: Legrand/Siemens/Schneider 4 Each
5 5 All as per item Sr. No: 2.00 but 160 Amps with breaking capacity 35 KA. \nMake: Legrand/Siemens/Schneider 4 Each
6 6 All as per item Sr. No: 2.00 but 200 Amps with breaking capacity 35 KA. \nMake: Legrand/Siemens/Schneider 5 Each
7 7 All as per item Sr. No: 2.00 but 250 Amps with breaking capacity 25 KA.\nMake: Legrand/Siemens/Schneider 4 Each
8 8 All as per item Sr. No: 2.00 but 320 Amps with breaking capacity 36 KA. \nMake: Legrand/Siemens/Schneider 2 Each
9 9 All as per item Sr. No: 2.00 but 400 Amps with breaking capacity 36 KA.\nMake: Legrand/Siemens/Schneider 2 Each
10 10 S & F in repair MCCB 3 pole 100 Amps with breaking capacity 16KA , 415 Volts, thermal & magnetic release including making all incoming/ outgoing connections fixed in repair complete all as specified and directed by Engineer in Charge.\nMake: Legrand/Siemens/Schneider 4 Each
11 11 All as per item Sr. No: 10.00 but 125 Amps with breaking capacity 16 KA.\nMake: Legrand/Siemens/Schneider 5 Each
12 12 All as per item Sr. No:10.00 but 160 Amps with breaking capacity 16 KA.\nMake: Legrand/Siemens/Schneider 5 Each
13 13 All as per item Sr. No: 10.00 but 200 Amps with breaking capacity 35 KA.\nMake: Legrand/Siemens/Schneider 6 Each
14 14 All as per item Sr. No:10.00 but 250 Amps with breaking capacity 35 KA.\nMake: Legrand/Siemens/Schneider 4 Each
15 15 S & F in repair Ampere meter digital type of ratio 0-500 Amp, size 95 Sqmm square type including making incoming/outgoing connections complete all as specified and directed.\nMake: AE/RISHABH/L & T 10 Each
16 16 S & F in repair Voltmeter digital type of ratio 0-415 volt , size 95 Sqmm square type including making incoming/outgoing connections complete all as specified and directed. 10 Each
17 17 M & L in repair for selector switch rotary type including making connections, complete all as specified and directed. 20 Each
18 18 M & L in repair for indicator lamp assembly LED type with red/green/blue including making connections complete all as specified and directed. 40 Each
19 19 M & L in repair for Current transformer (CT) ratio 100/5 including making connections complete all as specified and directed. 10 Set of 3
20 20 Repair/maint of Capacitor bank APFC panel of 10 KVAr to150 KVAr ,Disconnecting and taking out U/S LV capacitor,Protection brunch,Cooling fan,connectors,Power contactors, Controler,MCB etc from housing and including connection and testing to maint PF above 0.95 complete .(Capacitors and other items are paid seperatly in respective items.) 15 Each Job
21 21 S & F in repair TP MCB 63 Amps, with 10 kA breaking capacity complete all as specified & directed. \nMake : L&T/LEGRAND/HAVELLS 15 Each
22 22 S & F in repair TP MCB 40 Amps, with 10 kA breaking capacity complete all as specified & directed.\nMake : L&T/LEGRAND/HAVELLS 10 Each
23 23 S & F TP MCB 32 Amps, with 10 kA breaking capacity complete all as specified & directed.\nMake : L&T/LEGRAND/HAVELLS 15 Each
24 24 S & F power factor corrector relay upto 8 stage with programming complete all as specified. \nMake: EPCOS/L&T Cat Part No: etaCON L8/Havells 5 Each
25 25 S & F Capacitor duty contactor 3 pole, 3 KVAr, 1 NO 1 NC complete all as specified & directed.\nMake : L&T/EPCOS/HAVELLS 5 Each
26 26 S & F Capacitor duty contactor 3 pole, 5 KVAr, 1 NO 1 NC complete all as specified & directed.\nMake : L&T/EPCOS/HAVELLS 5 Each
27 27 S & F Capacitor duty contactor 3 pole, 8.5KVAr, 1 NO 1NC complete all as specified & directed.\nMake : L&T/EPCOS/HAVELLS 6 Each
28 28 S & F Capacitor duty contactor 3 pole, 10 KVAr, 1 NO 1 NC complete all as specified & directed.\nMake : L&T/EPCOS/HAVELLS 4 Each
29 29 S & F Capacitor duty contactor 3 pole, 12.5 KVAr, 1 NO 1 NC complete all as specified & directed.\nMake : L&T/EPCOS/HAVELLS 4 Each
30 30 S & F Capacitor duty contactor 3 pole, 20 KVAr, 1 NO 1NC complete all as specified & directed.\nMake : L&T/EPCOS/HAVELLS 4 Each
31 31 S & F Capacitor duty contactor 3 pole,25 KVAr, 1 NO 1NC complete all as specified & directed.\nMake : L&T/EPCOS/HAVELLS 4 Each
32 32 S & F PhiCap heavy duty Capacitor 1 to 4 KVAR, 3 phase, 415 Volts complete all as specified. \nMake : Epcos/Legrand/Havells 100 Per Kvar
33 33 S & F PhiCap heavy duty Capacitor 5-15 KVAR, 3 phase, 415 Volts complete all as specified.\nMake : Epcos/Legrand/Havells 150 Per Kvar
34 34 S & F PhiCap heavy duty Capacitor 20 -25 KVAR, 3 phase, 415 Volts complete all as specified. Make : Epcos/Legrand/Havells 150 Per Kvar
35 35 S & F Auto/Manual Selector Switch complete all as specified & directed. \nMake: L &T/ KAYCEE/ Legrand 10 Each
36 36 S & F LED ON/OFF indicator light complete all as specified & directed. \nMake: L &T/ KAYCEE/ Legrand 20 Each
37 37 M & L for cleaning of installation/ substation including clearing of vegitation, wild growth and trimming of grass etc around the installation compound and removing rubbish off the premises complete all as specified and as directed. 150 Sqm
38 38 M & L for rubbing rusted surface of LT panel/ feeder piller boxes of various sizes installed in various sub stations, cleaning the inner and outer surface of panel/ feeder piller box and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer including marking name of incomming and outging connection on LT panel complete all as specified and directed. 40 Each Job
39 39 M & L for cleaning of substation cable duct after removing HT/LT cable from duct by taking proper shutdown from power house including filling of new river bed fine sand under and around HT/LT cable to provide sand cushioing complete all as specified and directed. 25 Cum
40 40 M & L in repair for heat shrinkable straight through joint for PVC/XLPE insulated armoured cable of size upto 50 Sqmm 3.5/4 core complete all as specified and as directed.\nMake: Raychem/Denson/M-Seal 10 Each Job
41 41 All as per serial item No. 40.00 above but LT cable size of 70 to 150 Sqmm 10 Each Job
42 42 M&L for Electric yard gravelling of 15.0 cm (llose thickness) by broken stone of 40 mm size in and around two pole/ four pole structure/ substation complete all as specified and directed. 5 Cum
43 43 Dismantling unservicable/defective LT (Pin type,Shakle type)insulators of any size/type all as directed. 60 Each
44 44 M&L Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 50 mm height,65mm dia for 550 volts grade. 30 Each
45 45 M&L insulator Shakle type, porcelain, vitreous, white brown or green, shall be in one piece and shall have a groove on the side and a hole for a cotter pin and two galvanised bolts 12 mm dia and nuts with or without a pair of straps in size 31x3 mm as indicated size height 75 mm and dia 90 mm for working pressure 1100 volts complete as specified. 30 Each
46 46 Dismantling of Old ACSR conductor of Squarel type from LT Poles by taking shut down from respective feeder all as directed. 0.5 Per Qtl
47 47 M &L for ACSR conductor of Squarel type drawn on fixed to insulator on the pole complete as with permissable sags for OH conductor as per with indian electricity rules 1956 para 77 and 79 all as directed. 0.5 Per Qtl
48 48 Taking out LT UG cable from any type of soil and size all as directed by Engineer-in-Charge. 2150 RM
49 49 Supply and lay cable XLPE insulated Screened PVC bedded,galvanised steel strip or wire armoured,electric power cables(heavy duty) 1100 volts grade with stranded aluminium conductor of size 10.0 sq mm 2 core. 100 RM
50 50 Supply and lay cable XLPE insulated Screened PVC bedded,galvanised steel strip or wire armoured,electric power cables(heavy duty) 1100 volts grade with stranded aluminium conductor of size 16.0 sq mm 2 core. 100 RM
51 51 Supply and lay cable XLPE insulated Screened PVC bedded,galvanised steel strip or wire armoured,electric power cables(heavy duty) 1100 volts grade with stranded aluminium conductor of size 16.0 sq mm 4 core. 300 RM
52 52 Supply and lay cable XLPE insulated Screened PVC bedded,galvanised steel strip or wire armoured,electric power cables(heavy duty) 1100 volts grade with stranded aluminium conductor of size 25.0 sq mm 3.5 core. 200 RM
53 53 Supply and lay cable XLPE insulated Screened PVC bedded,galvanised steel strip or wire armoured,electric power cables(heavy duty) 1100 volts grade with stranded aluminium conductor of size 35.0 sq mm 3.5 core. 200 RM
54 54 Supply and lay cable XLPE insulated Screened PVC bedded,galvanised steel strip or wire armoured,electric power cables(heavy duty) 1100 volts grade with stranded aluminium conductor of size 50.0 sq mm 3.5 core. 150 RM
55 55 Supply and lay cable XLPE insulated Screened PVC bedded,galvanised steel strip or wire armoured,electric power cables(heavy duty) 1100 volts grade with stranded aluminium conductor of size 70.0 sq mm 3.5 core. 200 RM
56 56 Supply and lay cable XLPE insulated Screened PVC bedded,galvanised steel strip or wire armoured,electric power cables(heavy duty) 1100 volts grade with stranded aluminium conductor of size 120.0 sq mm 3.5 core. 800 RM
57 57 Supply and lay cable XLPE insulated Screened PVC bedded,galvanised steel strip or wire armoured,electric power cables(heavy duty) 1100 volts grade with stranded aluminium conductor of size185.0 sq mm 3.5 core. 40 RM
58 58 Supply and lay cable XLPE insulated Screened PVC bedded,galvanised steel strip or wire armoured,electric power cables(heavy duty) 1100 volts grade with stranded aluminium conductor of size 300.0 sq mm 3.5 core. 60 RM
59 59 M & L in repair RCC poles of 9 Mtr having bottom : 150 mm x 230 mm at top 130 mm x100 mm Grade M -25. all as specified. \n(Note : Earth work and PCC will be measured and paid separtely under relevent item of this schedule) 4 Each
60 60 Excavation in trenches 1.5 Mtr wide and not exc 1.5 Mtr deep in hard / dense soil, getting out and levelling of bottom surface to required level for laying UG cable / errection of poles / pipes all as specified. 135 Cum
61 61 Excavation in trenches 1.5 Mtr wide and not exc 1.5 Mtr deep in soft / disintegrated rock getting out and levelling of bottom surface to required level for laying UG cable / errection of poles / pipes all as specified. 405 Cum
62 62 All as per item No. 61.00 above but n.exc. 3.00m in depth and n.exc 1.5m in width in soft / disintegrated rock for errection of poles all as specified. 0.324 Cum
63 63 Excavation in trenches by cutting of road crossing / PCC hard standing, under boundary wall for laying of pipe/cable including making good the existing surface with same finish to match the original finish all as directed by Engineer-in-Charge. 3 Cum
64 64 Returning filling in excavated earth work including spreading, levelling, watering and well ramming in layers n.exc 25cm thick in any strata 349.5 Cum
65 65 Removing excavated soil to a distance n.exc 50m, depositing where directed at a level n.exc 1.5M above the starting point \n\n 190.5 Cum
66 66 Supply/ filling dry river sand/m-sand in trenches for cable protection All as SSR Part I.\nNote : Punned thickness only will be measured & Paid 121.5 Cum
67 67 Supply and laying un-reinforced precast concrete cable cover LV type 1 flate size 250 X 150 X 40 mm 10000 Each
68 68 Supply and lay GI Pipe medium grade 50 mm bore for cable protection as a guard pipe including required accessories etc. complete as specified and directed. 35 RM
69 69 M & L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate including use and waste of form work of concrete for any description incl preparation work is necessary all as directed. 14.4 Cum
70 70 M & L for PCC 1:3:6 type C-1 using 20 mm graded stone aggregate including use and waste of form work / mass concrete for coping of poles / using at any description all as dirceted. 2.16 Cum
71 71 M & L Earthing complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6mm thick, buried directly in ground vertically earth pit not less than 2.25 mtr deep below the ground level with top to edge of the plate n. less than 1.5 mtr below ground level connected to galvanized iron strip 25 x 4mm as earthing lead by means of blots, nuts, check nut and washer of galvanized steel, including necessary earth work and excavation in any strata and PCC 1:3:6 type C2 chamber and RCC cover and light grade GI pipe 40 mm dia pipe of required length for protection of GI wire and water funnel and wire mesh with GI pipe medium grade 20mm dia etc complete all as per electrical plate No 3 of SSR part - I and all directed including connections and testing on completion including dismantling old earthing. 8 Each
72 72 Supply and fix rubber matting ISI marked for 1.1 KV substation after replacing the unserviciable matts. 7 Each
73 73 Supply and fix in repair rigid type PVC Spacer for LT line with Spacer rod dia 13 mm and spacer hole dia 5-6 mm and spiral length 250 mm for 2 phase ACSR conductor 50 Each
74 74 Taking down and dismantling old unserviceable panel board any model, make, size including all acessories from various location complete. 1 Job
75 75 Supply, install, testing and commissioning of LT distribution panel board CPRI approved indoor type, horizontal type, double door system, weather proof, dust and vermin proof, made out of 50x50x6mm angle iron frame and 3.15mm thick CRCA sheet duly powder coated of suitable size with push type locking arrangement, factory assembled cubicle, pattern modular and compartmentalized construction, floor mounted free standing type, 3 phase 4 wire system including wiring with suitable size rated current carrying capacity aluiminium bus bar with epoxy insulated coating with colour code and insulated support, cable galleries, inter connecting bus bar connection / linkage complete and conforming to IS 8623 and IP 54 class of protection as per IS 2147 complete with following accessories and suitable for accomodate the Manual Change over switch 630 Amps , ACB 630 A as incoming and following MCCBs as outgoing etc complete and mounting the panel board on ground with PCC(1:3:6) bedding upto height of 30 cm above ground level complete all as specified and as directed by Engineer-in-Charge. 1 Job
76 75.01 (a) 1200Amps aluminium bus bar for all three phases and 1000 Amps for neutral-01 set.\n(b) MCCB TPN, 400 Amps, 415 V, 36 kA breaking capacity - 01 No (outgoing)\n(c) MCCB TPN,250 Amps, 415 V, 25kA breaking capacity - 02 No (outgoing)\n(d) MCCB TPN,100 Amps, 415 V, 16kA breaking capacity - 02 No (outgoing)\n(e) Control MCB SP 20 Amps 240 Volt 10 KA-04\n(f) Digital multi function meter (Volt meter 0-500V,Ammeter 0-800A, frequency meter & power factor meter.\n(g) CTs - set of three \n(h) Indicating lamp 240 volts LED type - set of three \n(i) Internal All links with copper conductor or solid aluminum bus bar of adequate capacity -01
77 76 Supply and fix in repair aluminium cable lugs for the following size of cable
78 76.01 (a) 16 Sqmm cable 10 Each
79 76.02 (b) 25 Sqmm cable 10 Each
80 76.03 (c) 35 Sqmm cable 15 Each
81 76.04 (d) 50 Sqmm cable 12 Each
82 76.05 (e) 70 Sqmm cable 15 Each
83 76.06 (f) 95 Sqmm cable 12 Each
84 76.07 (g) 120 Sqmm cable 15 Each
85 76.08 (h) 150 Sqmm cable 8 Each
86 76.09 (i) 185 Sqmm cable 8 Each
87 76.1 (j) 240 Sqmm cable 8 Each
88 76.11 (k) 300 Sqmm cable 5 Each
89 76.12 (l) 400 Sqmm cable 5 Each
90 77 Restringing, tightening of ACSR conductor of any size and type and GI continuous earth conductors of any size, maintaining standard sag including providing aluminum binding wire on LT over head lines and fixing of GI conductor complete all as specified and directed. 400 RM
91 78 Dismantling stay assembly complete all as directed 5 Per Set
92 79 Material and labour for stay assembly 20 mm dia complete with accessories as shown in electrical plate No. 1 complete all as specified and directed.\n(Note : excavation and concrete shall be measured separately) 5 Per Set
93 80 S & F in repairs cross arms bracing support, clamps and back plate fabricated from structural steel sections including nuts,bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat of red oxide zinc chrome, one under coat and one finishing coat of aluminium paint all as specified and directed. 2 Qtl
94 81 Taking down defective Security Light /perimeter lights /Post top lantern light of any size/pattern from existing place, checked and verified of serviceablity of all accessories, repairable Security Light set shall be re-fixing after repair/replacement defective parts/spares, complete testing all as directed.\n(Spares will be measured and paid separately as supply only under relevant item here in after). 100 Each
95 82 Supply only Heavy duty Copper wound ballast for HPSV/MH fitting 250 watts, Make: C& S/ Philips/ Bajaj /CG 10 Each
96 83 Supply only Heavy duty Copper wound ballast for HPSV/MH fitting 400 watts.\nMake: C& S/ Philips/ Bajaj /CG 30 Each
97 84 Supply only Electronic ballast for energy efficient light 2x24Watt T5 in fitting 4 x 24 wattsT/5 24 set \nMake: C& S/ Philips/ Bajaj /CG 10 Each
98 85 Supply only Electronic ballast for energy efficient light 2x36Watt CFL/FTL of \nMake : C& S/ Philips/ Bajaj /CG 10 Each
99 86 Supply only Lamp HPSV/MH 250 watts tubular type, base cap E - 40 of \nMake C& S/ Philips/ Bajaj /CG 10 Each
100 87 Supply only high wattage metal halide lamps 400 watts HPI-T-PLUS of Make C& S/ Philips/ Bajaj or equivalent 20 Each
101 88 Supply only Lamp suitable for 2X24watt FTL/CFL fittings \nMake: C& S/ Philips/ Bajaj CG 21 Each
102 89 Supply only Lamp suitable for T5 2X36 watt CFL fittings \nMake: C& S/ Philips/ Bajaj CG 22 Each
103 90 Supply only capacitor 33 Mfd 250V for Luminaires HPSV fittings complete Make C& S/ Philips/ Bajaj or equivalent 25 Each
104 91 Supply only Electronic Ignitor for HPSV/MH lamp fittings of capacity 15/250/400 watt, Cat Ref No. IGN112S/MH of Make C& S/ Philips/ Bajaj /CG 40 Each
105 92 Supply only Porcelain lamp holder, thread type suitable for 150/250/400 watts SV lamp fitting complete, ordering code No. LHYZ16000099 of Make C& S/ Philips/ Bajaj or equivalent 22 Each
106 93 M & L for Street light bracket made out of GI tubing 40 mm dia, light grade bend to shape suitable for above mentioned security light fittings with necessary MS clamps with one coat of anti corrosive primer and two coats of aluminium paint including nut, bolt, washers etc including taking out old unserviceable complete as specified. 25 Each
107 94 M & L in repair LED decorative post top lantern light with diffuser and painted aluminium deflector 60 watt of \nMake:C&S Model No.LTGL60WHPLED/W or equivalent in Philips/wipro 8 Each
108 95 Supply and fix in replacement of 60 Watt LED street light with pressure die cast aluminium housing & toughened glass with IP-66 degree protection, individual LED's must have peanut lenses for better throw across & along the road with luminarie efficacy of greater than 100 lumen/Watt (Minimum lumen output of luminarie should be 6000 Lumens) The luminarie should have 5 KV surge protection, PF > 0.95, and total harmonic distortion of THD < 10%, voltage range of 140-280V should be provided. The manufactures LOGO must be embossed/Engraved in the housing of the luminarie. Manufactures to provide LM80 from source manufacturer and should have adequate testing facilities approved by ministry of science (Govt of India) to provide LM 79 report complete all as specefied and directed by Engineer-in-Charge. Make : Bajaj CP No BRLEP60WLEDV2/ Jaquar Cat No.LSRT01S060XW or equivalent in Philips/Wipro 30 Each
109 96 S & F in repair cable junction boxes IP 66 protected “halogen free and weather proof” suitable for out door type ( with metric knockouts for cable entry) of size 139 x 119 x 70 mm incl necessary suitable size terminal connector single phase with neutral system mounted on saddles of suitable length and provn of aluminium cable lugs for incoming & out going LT cable connections with junction box fixing clamps made up of MS flat, nut and bolt on poles complete all as directed.\nMake : Sintex / National or equivalent 15 Each
110 97 Supply and fix in replacement of 25 Watt LED street light with pressure die cast aluminium housing & toughened glass with IP-66 degree protection, individual LED's must have peanut lenses for better throw across & along the road with luminarie efficacy of greater than 100 lumen/Watt. Luminarie should have top maintainable driver compartment for easy access to driver during maintenance. The driver used must be a constant current driver with efficiency of > 85%. The manufactures LOGO must be embossed/Engraved in the housing of the luminarie. Manufactures to provide LM80 from source manufacturer and should have adequate testing facilities approved by ministry of science (Govt of India) to provide LM 79 report complete all as specefied and directed by Engineer-in-Charge. \nMake : Bajaj CP No BRLREP25WLEDWH equivalent in C&S, Philips, Wipro 16 Each
111 98 M & L for preparation of old cement coated surface, cleaning the surface of the RCC street light Pole (LT) above the ground level incl coping area with 2 coats of ACC exterior emulsion paint over a coat of cement primer after preparation of surface including 12 cm black paint around the pole numbers/ letters in white. 50 Job
112 99 M & L prepration of old painted surface of LT pole and applying one coat of red oxide primer and 2 coats of aluminium paint to the pole. 20 Each
113 100 M & L prepration of old painted surface of LT cross arm,clamps etc and applying one coat of red oxide primer and 2 coats of aluminium paint for cross arms any numbers of each pole including clamps etc all as directed. 25 Each
114 101 Supply and Fix in repair 1 X 200 Watt LED Flood light luminarie with high pressure die cast housing with lens, IP 66 protected with all accessories and chain system and all as specified and directed by Engineer-in-Charge.(Cat Part No as per Make Jaguar Cat No LFLD02S200XW, Bajaj , philips) 8 Each
115 102 Supply and Fix in repair 1 X 120 Watt LED Flood light luminarie with high pressure die cast housing with lens, IP 66 protected with all accessories and chain system and all as specified and directed by Engineer-in-Charge.(Cat Part No as per Make Jaguar Cat no. LFLD02S0120XW or eqult in Bajaj/philips) 5 Each
116 103 Supply and Fix in replacement ACB four pole 630 Amps, 50 KA, microprocessor based, mannual draw out type with inbuilt 2 NO+2NC aux contact \nMake : L&T CP No SL96061, or equivalent schenider/C&S 1 Each
117 104 Supply and Fix in replacement onload manual change over switch 630 Amps , 4 pole , 415 V confirming to IEC 60947-3 1 Each
118 105 Supply and Fix in replacement onload manual change over switch 630 Amps , 4 pole , 415 V including sheet Steel enclosure confirming to IEC 60947-3 1 Each
119 106 S & F in repair GI tubing medium grade of size 40 mm dia as using pole for street lights or laying in trenches / on wall / poles / structures for road crossing / for cable protection etc,incl necessary provision for cable entry if reqd in street lights pole, fixing MS nut, bolt & washers / MS clamps complete as required all as directed. 44 RM
120 107 S & F in repair Analog type 24 hrs timer switches suitable for operation of street light luminarie with 4 pole Power contacotr of 32 A capacity - 01 No suitable for 3 Phase, 4 wire system incl necessary MCB TPN 6-32 A capacity - 01 No as control the system, fixed in the Outdoor type LT junction box madeup of powder coated CRCA sheet steel enclosure 3 mm thick floor mounted of suitable size all as specified and as directed. 2 Each
121 108 S& F in replacement circuit for three phase temperproof digital meter equipped with 6 digit ultra bright LED counter , direct operation upto20-200Amp ( with CT ), operating on 415 Volt single phase , direct read withaut multiplication factor, Latest microcontroller based technology, Mains LED to indicate presence of auxillary supply, error indication for faulty/ reverse connections etc reassembling to make meter serviceable , all as specified and directed by Engineer-in-Charge. 3 Each
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail