Development Of Ice Skating Rink At Shimla Himachal Pradesh Development Of Ice Skating Rink At Shimla , Himachal Pradesh, Ice Skating Rink Shimla-Himachal Pradesh

Himachal Pradesh Tourism Development Corporation Limited-HPTDC has published Development Of Ice Skating Rink At Shimla Himachal Pradesh Development Of Ice Skating Rink At Shimla , Himachal Pradesh. Submission Date for this Tender is 31-08-2019. Skating Ring Tenders in Ice Skating Rink Shimla Himachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

21204024
Development Of Ice Skating Rink At Shimla Himachal Pradesh Development Of Ice Skating Rink At Shimla , Himachal Pradesh
Open Tender
Indian
Himachal Pradesh
Ice Skating Rink Shimla
31-08-2019

Tender Details

Development Of Ice Skating Rink At Shimla Himachal Pradesh Development Of Ice Skating Rink At Shimla , Himachal Pradesh

Key Value

Document Fees
INR 5000 /-
EMD
INR 500000.0 /-
Tender Value
INR 12.02 Crore /-

BOQ Items

Sl. No. Item Description Item Code / Make Quantity Units
1 1 Cutting in Earth Work in all kind of soil/earth work including soft and hard rock and stacking of excavated earth within all leads and lifts as directed within and outside including loading/unloading of surplus excavated materials through manual & mechanical transport. Dumping site will be arranged by the contractor himself and the charges of dumping site and disposal of surplus excavated materials shall also be borne by the contractor. Any damage to the Govt./private property during the excavation will be the entire responsibility of the contractor. BI01010001010000000000000515BI0100001113 10131.5 cum
2 2 Excavation in foundation trenches in earth work in all kinds of soil and soft/hard rock including chiseling/wedging out of rock etc including pumping/dewatering etc. and stacking the excavated soil not more than 3.00 meter clear from the edge of the excavation and than returning the stacked soil in 15cm layers, when required into plinth, sides of foundation etc. consolidating each deposited layer by ramming, watering and then disposing of all surplus earth upto the dumping site selected by the contractor through manual & mechanical means including loading/unloading etc. complete. No additional rates/amount will be paid for dumping and disposal of excavated earth. BI01010001010000000000000515BI0100001114 4639.36 cum
3 3 Filling available excavated earth within the site in trenches, plinth, sides of foundation etc. in multi layers not exceeding 20 cm in depth: consolidating each deposited layer by ramming and watering etc. complete and as per the direction of the Engineer In charge. BI01010001010000000000000515BI0100001115 692.894 cum
4 4 Filling in plinth with sand under floors as per specification and direction of Engineer In charge including watering ramming, consolidating and dressing etc. complete I/c cost of sand and carriage of material in all leads & lifts. BI01010001010000000000000515BI0100001116 260.806 cum
5 5 Providing Form work with steel plates 3.15 mm. thick welded with angle iron in frame 30X30X5 mm. so as to give a fair finish including centering, shuttering and propping etc. with wooden battens and ballies, heights of propping and centering below supporting floor to ceiling not exceeding 6 mtrs. and removal of the same for insitureinforced concrete and plain concrete work in : (Shuttering as per the pattern specified in the architectural drawings including smooth surfaces and carriage of material upto all leads and lifts and as per directions of engineer in charge). BI01010001010000000000000515BI0100001117
6 5.1 Foundation, footings basis of columns etc. and mass of concrete I/c carriage of material within all leads and lifts. BI01010001010000000000000515BI0100001118 1093.43 sqm
7 5.2 Sides and soffits of beams, beam haunchings, cantilevers, bressumers and lintels not exceeding 1 mtr. In depth in all heights from floor i/c carriage of material within all leads and lifts. BI01010001010000000000000515BI0100001119 599.611 sqm
8 5.3 Flat surfaces such as soffits of suspended floors, roofs, landlings, balconies and access platform i/c carriage of material within all leads and lifts. BI01010001010000000000000515BI0100001120 3288.24 sqm
9 5.4 Columns, pillars,posts and struts square, rectangular and polygonal in plan i/c carriage of material within all leads and lifts. BI01010001010000000000000515BI0100001121 409.45 sqm
10 5.5 Staircase with sloping or stepped soffits excluding landings i/c carriage of material within all leads and lifts. BI01010001010000000000000515BI0100001122 63.45 sqm
11 5.6 Vertical surfaces such as walls (any thickness) partitions and the like including attached pillasters buttress Plinth and string courses and the like i/c carriage of material within all leads and lifts. BI01010001010000000000000515BI0100001123 3782.4 sqm
12 6 Providing and laying cement concrete 1:4:8 (1 cement, 4 sand, 8 aggregate 20 mm nominal size excluding cost of centering and shuttering- All work upto Plinth Level I/c carriage of material in all lead and lift. BI01010001010000000000000515BI0100001124 491.607 cu mtr
13 7 Providing and laying cement concrete 1:5:10 (1 cement , 5 sand, 10 aggregate 40 mm nominal size) with 15 % plum and curing complete excluding the cost of form work in retaining walls, walls under Plinth beams, the size of plum shall usually be 150 mm to 300mm as per HPPWD specifications and direction of the Engineer in Charge and carriage of materials in all lead & lift. BI01010001010000000000000515BI0100001125 168.179 cum
14 8 Providing and laying cement concrete 1:5:10 (1 cement, 5 sand, 10 aggregate 20 mm nominal size excluding cost of centering and shuttering-in foundation and Plinth I/c carriage of material within all leads and lifts. BI01010001010000000000000515BI0100001126 213.991 cum
15 9 Providing and laying upto first floor two levels RCC 1:2:4 (1 cement: 2 sand: 4 graded stone aggregate 20 mm nominal size) to give a smooth and even surface including centering and shuttering etc but excluding the cost of reinforcement in mouldings as in cornices windows, sills etc. not exceeding 15 cm in girth upto all floor level as per specifications and direction of the Engineer in Charge including carriage of materials in all lead & lift. BI01010001010000000000000515BI0100001127 86.8393 cum
16 10 Providing and laying design cement concrete conforming to grade M25 using graded crushed stone aggregate 20 mm nominal size with minimum cement 400 kg/cumt mechanically mixed & vibrated & curing complete excluding the cost of formwork and reinforcement for RCC work as per direction of engineer In charge including carriage of materials within all leads & lifts and upto all floor level. BI01010001010000000000000515BI0100001128
17 10.1 foundation footings and bases of columns and the like mass concrete work in : BI01010001010000000000000515BI0100001129 1396.26 cum
18 10.2 Suspended floor, roof, landing shelves, chajjas, and their supports balconies, beams, girders, bresumers and cantilecer. BI01010001010000000000000515BI0100001130 405.62 cum
19 10.3 Columns,pillars, posts, struts. BI01010001010000000000000515BI0100001131 233.12 cum
20 10.4 Wall (any thickness but not less than 0.1 m thickness )attached plasters, buttresses, Plinth and string courses etc. from top of foundation level and upto all floor level. BI01010001010000000000000515BI0100001132 421.869 cum
21 10.5 Stair cases (except spiral staircases) excluding landing but not including preparing of the surface and finishing of the nosing. BI01010001010000000000000515BI0100001133 40.3461 cum
22 11 Providing steel Reinforcement for R.C.C work including straightning, cutting, bending, placing in position and binding etc. all complete including cost of binding wire and carriage of material within all leads and lifts and upto all height. \na) Mild steel and medium tensile steel/bar, Fe 500 \nb) Thermo-mechanically treated barsTATA/JSW/JSPL/SAIL BI01010001010000000000000515BI0100001134 299666 kg
23 12 Applying a coat of hot bitumen (mexphalt 80/100 or equivalent) using 1.70kg. Per, square meter on damp proof corse after cleaning the surface with a piece of cloth lightly soaked with kerosene complete as per specification & direction of the Engineer in Charge including carriage of materials in all lead & lift. BI01010001010000000000000515BI0100001135 89.8307 sqm.
24 13 Applying cement slurry on R.C.C. slab or cement concrete work using 2.75 kg of cement per sq. metre of floor area before laying cement concrete flooring including roughening, cleaning of the concrete surfaces complete I/c carriage of material within all leads and lifts BI01010001010000000000000515BI0100001136 3328.03 sqm
25 14 Providing and throating or plaster drip and molding to RCC chajja with C.M. 1:3 complete as per specification and direction of Engineer In charge including carriage of materials in all lead & lift. BI01010001010000000000000515BI0100001137 232.44 mtr
26 15 Providing and laying damp proof course 50 mm thick with cement concrete 1:2:4 (1 cement:2 sand:4 graded stone aggregate 20mm nominal size) and curing complete including carriage of materials in all lead & lift. BI01010001010000000000000515BI0100001138 91.3353 sqm
27 16 Brick work using bricks of 2nd class designation and as per specifications in superstructure above pinth level upto all floor levels in cement mortar 1 :6 (1 cement : 6 coarse sand) I/c carriage of materials within all leads & lifts and upto all height. BI01010001010000000000000515BI0100001139 325.221 cum
28 17 Half brick masonry with bricks of 2nd class as per specifications in superstructure above plinth level upto all floor level I/c carriage of material within all leads and lifts in cement mortar 1:4 (1 cement: 4 course sand) with hoop iron. BI01010001010000000000000515BI0100001140 352.63 sqm
29 18 Boulder (Broken to required size) filling of selected hard stone dry hand packed under floors and behind retaining walls I/C carriage of material within all leads and lifts BI01010001010000000000000515BI0100001141 383.403 cum
30 19 Random rubble masonry with hard stone in foundation and plinth including leveling up with cement concrete 1 :6 :12 (1 cement :6 coarse sand :12 graded stone aggregate 20 mm nominal size) at Plinth level I/c carriage of material within all leads and lifts with cement mortar 1:6 (1 cement :6 coarse sand) BI01010001010000000000000515BI0100001142 26.1624 cum
31 20 Providing and laying 20 cm thick composite stone masonry with stone facing of chiesel dressed stones one line dressed in cement mortar 1:6 (1 cement :6 course sand ) and concrete 1 :3 :6 (1 cement : 3 course sand: 6 graded stone aggregate 20 mm nominal size) on inner face of the wall including centering, shuttering and propping complete upto floor two level and above including carriage of materials in all lead & lift. BI01010001010000000000000515BI0100001143 114.974 sq. mtr
32 21 Providing wood work in frames of doors, windows, clearstorey windows and other frames and fixed in position. 2nd class seasoned deodar wood including carriage of materials in all lead & lift. BI01010001010000000000000515BI0100001144 3.00791 cumt
33 22 Providing and fixing to position flush door shutters decorative type core of block board construction with frames of first class hard wood and well matched First class Indian teak ply vaneeing with vertical or crossed grains on both sides of shutter oncluding black enameled butt hinges etc. complete as per drawings, design, specifications and direction of the engineer In charge including carriage of materials in all lead & lift.\na) 40mm thick BI01010001010000000000000515BI0100001145 103.29 sqm
34 23 Providing and fixing woodwork in frames of false ceiling, Partitions etc sawn and putup in position complete. Second class seasoned deodar wood including cost of beading/corner/molding etc. complete and carriage of materials in all lead & lift. BI01010001010000000000000515BI0100001146 1.50439 cu mtr
35 24 Providing and fixing to position eves board 200X25mm thick including fixing in position and to design/pattern. 2nd class seasoned deodar wood including carriage of materials in all lead & lift. BI01010001010000000000000515BI0100001147 408.386 RMT
36 25 Providing and fixing Gypsum board of 12.5mm thick in ceiling (ISI mark) of approved quality as per directions of Engineer In charge including cost of beading/corner/molding etc. complete and carriage of material upto all leads, lifts and height. BI01010001010000000000000515BI0100001148 367.912 sqmtr
37 26 Providing and fixing wooden plank ceiling on plain curved surface with tounged and grooved jointing and wood screws as per drawings, design/pattern, specification and direction of the Engineer-In charge including cost of beading/corner/molding etc. complete and carriage of materials in all lead, lift and height. 2nd class seasoned Deodar wood.\n20mm thick. BI01010001010000000000000515BI0100001149 150 sq mtr
38 27 Providing and fixing bright finished brass 100mm mortice latch lock (ISI marked/approved quality) with six levers and pair of anodized (anodic coating not less than grade AC 10 as per IS: 1868) aluminum lever handles with necessary screws etc. complete including carriage of materials in all lead & lift. BI01010001010000000000000515BI0100001150 80 each
39 28 Providing and fixing 100mm bright finished brass floor door stopper with rubber cushion complete (Heavy duty, ISI mark) including carriage of materials in all lead & lift. BI01010001010000000000000515BI0100001151 80 each
40 29 Providing and fixing 40 X 3 mm flat iron hold fast 40 cm long including fixing to frame with 10mm diameter bolts and nuts and wooden plugs and embedding in cement concrete block 30X10X15 , 1:3:6 (1 cement : 3 sand : 6 graded stone aggregate) including carriage of materials in all lead & lift. BI01010001010000000000000515BI0100001152 300 each
41 30 Providing and fixing to position 12mm thick Toughened glass of approved quality to doors, windows and glazings including SST fittings etc complete in all respects as per direction of the Engineer In charge including carriage of materials in all lead & lift. BI01010001010000000000000515BI0100001153 76.66 sq mtr
42 31 Providing and fixing 8 mm thick Waterproofing Cement Board including fixing with self screws with preprinted limpet and rubber washers etc. complete (ISI Mark) with all accessories as required and as per the direction of Engineer in charge including carriage of materials in all lead & lift. BI01010001010000000000000515BI0100001154 1172.67 sq mtr
43 32 Providing and fixing teak wood finish wall paneling in Entrance lobby with 6mm grooves in it as shown in drg. and design/pattern with 4mm thick teak ply over 19 m.m. waterproof plywood (ISI Mark) with melamine polish finish etc. complete as per specification and direction of Engineer-In charge including beading/corner etc. complete including carriage of materials in all lead & lift. BI01010001010000000000000515BI0100001155 135.922 sq mtr
44 33 Providing and fixing 5mm thick sheet glass of approved quality to fixed position of window frame with wooden beading etc.including cost of beading and carriage of materials in all lead & lift. BI01010001010000000000000515BI0100001156 54.05 sqm
45 34 P/F 8 mm thick calcium silicate board ceiling (ISI Mark) to external chajja projections as per drawings, design/pattern, specification and direction of Engineer-In charge including cost of beading/corner/molding etc. complete and carriage of materials in all lead & lift. BI01010001010000000000000515BI0100001157 672.136 sq mtr
46 35 Providing and fixing 75mmx600mm size Tile Cladding on face of building of standard/approved make colour/shade and jointed with cement slurry i/c scaffolding etc. on 12mm. Thick cement mortar 1:3 (1cement:3 sand) complete as per direction of Engineer-In charge including carriage of materials in all lead & lift. BI01010001010000000000000515BI0100001158 84.135 sq mt
47 36 Providing and laying Duro stone vitrified tiles (300x300mmx10mm) of approved colour/shade in flooring, treads of steps and landing laid on a bed of 12mm thick cement mortar 1:3 (1 cement : 3 sand) laid over and jointed with neat cement slurry finished with flush pointing in white cement mixed with pigment of required shade to match the shade of tiles complete upto all floor level including carriage of materials in all lead & lift. BI01010001010000000000000515BI0100001159 267.287 sq mt
48 37 Providing and laying Digital tiles (300x600mmx10mm) in of approved & required colour/shade in skirting risers of steps and dados on 12mm thick cement mortar 1:3 (1cement : 3 sand) laid over and jointed with neat cement slurry finished with flush pointing in white cement mixed with pigment of required shade to match the shade of tiles complete upto all floor level including carriage of material upto all leads & lifts and as per direction of Engineer In charge. BI01010001010000000000000515BI0100001160 443.186 sqm
49 38 Providing and laying (600X 600) 10mm thick (average) anti skid acid proof, stain and impact resistant tile flooring of approved make/manufacture and colour/shade laid on bed of 12mm thick cement mortar 1:3, jointing with tile pigment to match the shade of tile complete as per specifications & direction of Engineer-In charge up to all floor level including carriage of materials in all lead & lift. BI01010001010000000000000515BI0100001161 1124.35 sqmt
50 39 Providing and laying granite stone slab over cooking shelf/basin counter base in cement mortar 1:3 (1 cement : 3 sand) and joined with grey cement slurry mixed with pigment to match the shade of granite stone including cutting in sizes/holes, rubbing and polishing etc. complete as per drawings, design and specifications including all lead, lift & height/level.\na) 20mm thick BI01010001010000000000000515BI0100001162 670.412 sqmtr
51 40 Providing and laying flamed granite stone of approved quality in risers of steps,skirting, dado and pillars laid on 12mm (average)thick base of cement mortar 1:3(1cement: 3 sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of granite stone i/c rubbing and polishing etc. complete as per drawing, design/pattern, specifications and direction of Engineer In charge including carriage of material upto all leads, lifts and level/height.\n20mm (average) thickness BI01010001010000000000000515BI0100001163 581.91 sqmtr
52 41 50 mm thick cement concrete flooring with metallic concrete hardner topping, under layer of 45 mm thick cement concrete 1:2:4 (1 cement: 2 sand:4 graded stone aggregate 20 mm nominal size) and top layer of 15mm thick metallic cement hardner consisting of mix 1:2 (1 cement hardner mix: 2 stone aggregate 6mm nominal size) by volume, with which metallic hardening compund of approved quality is mixed in the ratio 4:1 (4 part of cement : 1 part of metallic floor hardening compund of approved quality by weight) including finishing etc. complete as per specification and direction of the Engineer-Incharge including carriage of materials in all lead & lift and upto all floor level. BI01010001010000000000000515BI0100001164 488.959 sq mtr
53 42 Making full round mouldings in vertically/horizontally to marble/granite stone in edges of slab, stairs steps and in lift opening etc. including making groves/pattern as per drawings, specifications and direction of Engineer-Incharge including carriage of materails in all lead & lift. BI01010001010000000000000515BI0100001165 836.832 meter
54 43 Providing and laying 150 X 300 mm , 10 mm thick slate stone cladding of approved quality, shade & colour to projections of the building with cement mortar 1:4 laid complete as per drawings, design and specification including carriage of materials in all lead, lift and height.. BI01010001010000000000000515BI0100001166 610.29 sq mtr
55 44 Providing and laying Basalt stone of approved quality, colour, shade & size in wall cladding 20mm (average) thickness base of cement mortar 1:3(1cement: 3 sand) laid over and jointed with cement slurry mixed with pigment to match the shade of basalt stone i/c rubbing and polishing etc. complete as per drawing, design and specifications including carriage of material upto all lead,lifts, height and as per direction of Engineer Incharge. BI01010001010000000000000515BI0100001167 333.499 sq mtr
56 45 Providing and laying Brick tile terracing (hand moulded) in all patterns, slopes, profile bends as per design given by the architect including 100 mm thk Mud Phuska on Roofs laid to slope, consolidating and plastering with 25 mm thk Mud mortar mixed with phuska at 35 kg per cu.m. of each and grouting with cement mortar (1:4) including grouting with cm 1:2 finished complete, with necessary pointing in 1:1 mortar etc. complete as per specifications and direction of the Engineer Incharge and carriage of materials in all lead & lift. BI01010001010000000000000515BI0100001168 12.7512 sq mtr
57 46 Providing and laying granite Cobble stone having size of 150x100x100mm of approved quality & shade/ colour in flooring 20mm(average) thickness base of cement mortar 1:3(1cement: 3 sand) laid over and jointed with cement slurry mixed with pigment to match the shade of granite stone etc. complete as per approved drawing, design/pattern and specifications including carriage of materiasl in all leaed, lift and direction of Engineer Incharge. BI01010001010000000000000515BI0100001169 250 Sq.m
58 47 Providing and laying heavy duty precast cement conrete inter locking paver blocks vibro compacted upto M- 50 grade i/c border or kurb block grey or coloured over 25mm thick average base thickness of cement mortar 1:4 (1 cement : 4 sand) laid over and jointed with neat cement slurry mixed with pigment to match the shade of blocks i/c curing rubbing & polishing etc. complete including carriage of materials in all lead & lift. 80mm thick NITC make. BI01010001010000000000000515BI0100001170 815.9 Sq.m
59 48 Slate roofing with 7.5 cm.Single lap single layer fixed on wooden batten/planks of approved quality colour & shade as per drawing, design and specifications including carriage of materials in all lead & lift and direction of the Engineer Incharge. (wood work to be paid for separately) \n400x200 cm and 12mm thick BI01010001010000000000000515BI0100001171 1015 sq mtr
60 49 Providing and fixing 0.60 mm thick preprinted steel in roofing with hot dipped metallic zinc coated sheet with top coat of regular modified polyster (RNP) organic coating of 20 microns over 5 micron primer coating including fixing with prepainted with self drilling screws with prepainted limpet and rubber washers etc. complete with all accessories as required and as per the direction of Engineer in charge including carriage of materials in all lead & lift. TATA/SAIL BI01010001010000000000000515BI0100001172 510.974 sqmt
61 50 Providing and fixing ridges or hips 60cm overall with 0.60 mm thick prepainted steel sheets in roofing with hot dipped metallic zinc coated sheets with top coat of regular modifies polyester organic coating of 20 microns primer coating + back coat of polyster of 5 microns over 5 microns primer coating including fixing with self drilling steel screws of required sizes with all accessories as required and as per the direction of Engineer in charge including carriage of materials in all lead & lift. BI01010001010000000000000515BI0100001173 165.57 rmt
62 51 Providing and fixing valley 60cm overall 0.60mm thick prepainted steel sheet in roofing with hot dipped metallic zinc coated sheet with top coat of regular modifies polyster organic coating of back coat of polyster of 5 microns over 5 microns primer coating including fixing with 6mm prepainted self drilling screws of required size including GI limpet & bitumen washers with all accessories as required and as per the direction of Engineer Incharge including carriage of materials in all lead & lift. BI01010001010000000000000515BI0100001174 72.2 RMT
63 52 Providing and fixing on wall face/duct CI rain water pipes including filling the joints with spun yarn and cement mortar 1:2 (1 cement : 2 sand) 100 dia pipe, ISI Mark including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001175 200 meter
64 53 Providing and laying water proofing treatment to vertical and horizontal surfaces of retaining walls, depressed portions of toilets, kitchens and the like consisting of applying cement slurry @ 4.4 kg/sqmt mixed with water proofing compund/ liquid of pidilite/sika/snowcern conforming to IS 2645 in recomended proportions. IInd course of 20mm plaster in cement mortar 1:3 (1 cement : 3 sand) mixed with water proofing compound/liquid in recomended proportion as per specifications, IIIrd course of applying blown or ersidual bitumen applied @1.7 kg/per sqmt of area, IVth course of 400 micren thick PVC sheet (overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other bitumen @ 1.7 kg/sqmt. etc. complete as per specifications and direction of the Engineer Incharge including carriage of materials in all lead & lift. BI01010001010000000000000515BI0100001176 4432.79 sqm
65 54 Providing and fixing 15 cm. wide 45 cm. overall semicircular plain G.I. sheet gutter with iron brackets 40x3mm size bolts and nuts and washers etc. including making necessary connections with rain water pipe complete as per design including carriage of materials in all lead & lift and direction of the Engineer Incharge. \n0.80mm thick sheet. TATA/SAIL. BI01010001010000000000000515BI0100001177 333.54 Mtr
66 55 Steel work welded in built up sections in trusses and framed work including cutting, hoisting , fixing in position and applying a priming coat of red lead paint within all leads and lifts.\nIn beams, joints, channels, angles, tee, flats with connecting plates of angle cleats\nTATA/SAIL/Jindal steel & power BI01010001010000000000000515BI0100001178 365.712 qtl
67 56 Steel work welded in built up sections in gratings framed guard bars, ladders, railings, brackets and similar work including carriage of materials in all lead & lift.\nTATA/SAIL/Jindal steel & power/APPOLO BI01010001010000000000000515BI0100001179 10.35 qtl
68 57 Supplying and fixing rolling shutters of approved make made of 80 mm X 1.25mm M.S laths interlocked together through their entire length and joined together at the end by end locks mounted on specially designed pipe shaft,with brackets side guides and arrangements for inside and outside locking with push pull operation complete but excluding the cost of the top cover and spring etc. complete as per specifications including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001180
69 57.1 Shutters having width below 3.5 metres BI01010001010000000000000515BI0100001181 54 sqm
70 58 Providing and fixing 27.5 centimetre long wire spring grade No.2 for rolling shutters. BI01010001010000000000000515BI0100001182 8 Each
71 59 Providing and fixing top cover for rolling shutter. Shutters having width below 3.5 metres BI01010001010000000000000515BI0100001183 22.4 Rmt.
72 60 Providing and fixing ball bearing for rolling shutters complete as per specification including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001184 8 Each
73 61 Providing and fixing to position UPVC three track panels sliding windows of approved make and BIS standars certified color laminated golden OAK with flyscreen mesh SS 304 grade, with outer frame 112mm/52mm sliding slash 84 mm/42mm etc. complete as per drawings, design, specification and direction of the Engineer Incharge and carriage of materials in all lead & lift. BI01010001010000000000000515BI0100001185 236.4 sq mtr
74 62 Providing and fixing to position as per the drawings and design SST railing made out of pipes, Tubes and handrails of SS 304 grade, baluster fixed to alternate tread complete in all respects as per drawings, design, specification and direction of the Engineer Incharge and carriage of materials in all lead & lift. BI01010001010000000000000515BI0100001186 360.38 meter
75 63 Providing and fixing Powder coated aluminum work for door, window, ventilators and partitions with extruded built up standard tubular and other sections of approved make conforming to IS 733 and IS 1285 transparent or dyed to required shade according to IS 1868. (Minimum anodic coating of grade AC 15) fixed with raw plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/ neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically where ever required including cleat angle, aluminum, snap beading for glazing/panelling C.P.brass/stainless steel screws complete as per architectural drawings , design/pattern, specifications and the directions of Engineer-In-Charge including carriage of materials in all lead & lift. BI01010001010000000000000515BI0100001187
76 63.1 For doors windows and ventilators and glazed portions frames. For fixed portion. BI01010001010000000000000515BI0100001188 10.83 kg
77 64 Applying priming coat over new steel and other metal surfaces of approved make & colour after and including preparing the surfaces by cleaning all dirt dust and other foreign matter with wire brushes, fine steel wool scrapper and sand paper with ready mix red lead paint including carriage of materials in all lead & lift and direction of the Engineer Incharge. \nAsian/Nerolac or equivalent make. BI01010001010000000000000515BI0100001189 1015.72 sqmt
78 65 Painting two coats (excluding priming coat) on new steel and other metal surfaces with enamel paint of approved make & colour brushing to give an even shade including cleaning the surface of all dirt, dust and other foreign mateer I/c carriage of materials in all leads and lifts.\nAsian/Nerolac or equivalent make. BI01010001010000000000000515BI0100001190 1015.72 sqmt
79 66 Applying priming coat over new wood and wood based surfaces of approved brand after and including preparing the surface thoroughly cleaning the surface for oil grease, dirt, dust and other foreign matter sand papering and knotting I/c carriage of materials in all leads and lifts with ready mixed paint brushing wood primer pink. Asian/Nerolac or equivalent make. BI01010001010000000000000515BI0100001191 133.069 sqmt
80 67 Painting two coats (excluding priming coat) on new wood and wood based surfaces with ready mix enamel paint of approved quality & shade/colour to give an even shade including cleaning the surface of all dust and other foreign matter sand papering and stopping I/c carriage of materials in all leads and lifts \nAsian/Nerolac or equivalent make. BI01010001010000000000000515BI0100001192 133.065 sqmt
81 68 Applying Birla/JK wall care putty over plaster surface after thoroughly brushing the surface free from mortar drops, dust loose materials and other foreign matters sand papered smooth to give final matter finish to the surface complete including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001193 8427.5 sqmt
82 69 Finishing wall with weather proofing exterior grade emulsiont of approved make manufacture and of required shade on undercorated wall surface (two coats) to give an even shade after thoroughly brushing the surface to remove all dirt dust and other foreign matter I/c carriage of materials to all leads and lifts. Asian/Nerolac or approved make. BI01010001010000000000000515BI0100001194 2111.78 sqmt
83 70 Wall painting (two coats) with plastic emulsion paint of approved brand/ manufacture and colour/shade on undercorated wall surface to give an even shade including thoroughly brushing the surface free from mortar dropping and other foreign matter and sand prepared smooth including applying of putty a required for making the surface including carriage of materials in all lead & lift and direction of the Engineer Incharge. Asian/Nerolac or equivalent make. BI01010001010000000000000515BI0100001195 6834.03 sqmt
84 71 Applying one coat of distemper primer of approved brand/manufacture and colour/shade on wall surfaces after thoroughly brushing the surface free from mortar dropping and other foreign matters and including preparing the surface even and sand papered smooth including carriage of materials in all lead & lift and direction of the Engineer Incharge. \nAsian/Nerolac or equivalent make. BI01010001010000000000000515BI0100001196 9949.19 sq mt
85 72 6mm cement plaster to ceiling in cement mortar 1:4 (1 cement :4 sand) I/c carriage of material within all leads, lifts & height/level. BI01010001010000000000000515BI0100001197 6464.27 sqm
86 73 15mm cement plaster in single coat on the rough side of brick/concrete/stone walls for interior plastering upto all floor levels including arrises, champhers and /or rounded angles not exceeding 80 mm in girth and finished even and smooth with cement mortar 1:6 (1 cement : 6 sand) I/c carriage of material within all leads and lifts BI01010001010000000000000515BI0100001198 3337.74 sqm
87 74 20mm cement plaster in single coat on the rough side of brick/stone masonry for interior plastering upto all floor levels including arrises, champers and /or rounded angles not exceeding 80mm in girth and finished even and smooth with cement mortar 1:6 (1 cement : 6 sand) I/c carriage of material within all leads and lifts BI01010001010000000000000515BI0100001199 1344.56 sqm
88 75 Stuco Plaster with Fine Granular Sand complete as per specification and direction of the Engineer Incharge including carriage of materials in all lead, lift and height/level. BI01010001010000000000000515BI0100001200 1174.07 sq mtr
89 76 Providing and applying 10 mm thick POP Punning for smooth surface over cement plaster on walls and Ceiling complete as per design, specification and direction of the Engineer Incharge including carriage of materials in all lead & lift. BI01010001010000000000000515BI0100001201 3151.59 sq mtr
90 77 Making of Groove in plaster complete as per specification, design/pattern and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001202 1000 meter
91 78 Providing plinth protection 50mm thick in cement concrete 1:3:6 (1 cement : 3 sand : 6 graded stone aggregate 20mm nominal size) including carriage of material in all lead and lifts BI01010001010000000000000515BI0100001203 316.4 sq mt
92 79 Providing Under layer of plinth protection of 75mm thick (unconsolidated ) bed dry brick or stone aggregated 40mm nominal size with rammed and consolidated and grouted with fine sand including preparation of ground complete as per direction of the Engineer Incharge including carriage of materials in all lead & lift. BI01010001010000000000000515BI0100001204 277.56 sq mt
93 80 Providing and laying Screeding 50mm thick in cement concrete 1:3:6 (1 cement : 3 sand : 6 graded stone aggregate 6mm nominal size) including carriage of material in all lead and lifts BI01010001010000000000000515BI0100001205 2066.57 sq mtr
94 81 Providing Niche for Sculpture and mural (4.97mX4.97m) as per the drawing, design/pattern, specification and direction of Engineer Incharge including carriage of materials in all lead & lift. BI01010001010000000000000515BI0100001206 1 JOB
95 82 Demolition above G.L.upto floor two level and above including disposal of unserviceable materials within all lead & lift through manual & mechanical means and loading/unloading etc. complete upto the dumping site to be arranged by the contractor himself including stacking the reinforcement to the specified manners as directed by the Engineer Incharge. No additional rate/amount will be paid. BI01010001010000000000000515BI0100001207
96 82.1 Un-reinforced cement concrete upto 15cm. thickness. BI01010001010000000000000515BI0100001208 376.188 cum
97 83 Demolition of brick work below G.L. upto all depth including stacking of serviceable materials and disposal of un-serviceable materials within all lead & lift through manual & mechanical means including loading/unloading etc. complete and as per the direction of Engineer Incharge. BI01010001010000000000000515BI0100001209
98 83.1 In Cement mortar.\n BI01010001010000000000000515BI0100001210 175.26 cum
99 84 Demolition of stone masonry below G.L. upto all depth including stacking of serviceable materials in specified manners and disposal of dismantled /demolished material/ malba /debris through manual & mechanical means upto the dumping site arranged by the contractor and as per the direction of Engineer Incharge. No additional rate/amount will be paid towards disposal and dumping charges. BI01010001010000000000000515BI0100001211
100 84.1 Rubble masonry in cement mortar. BI01010001010000000000000515BI0100001212 282.6 cum
101 85 Dismantling roofing including ridges, hips, valleys, gutters etc. and stacking the serviceable materials in proper manners as per the direction of Engineer Incharge including disposal of un-serviceable materials upto the dumping site arranged by the contractor. No additional rate/amount will be paid towards disposal and dumping charges. BI01010001010000000000000515BI0100001213
102 85.1 G.I. Sheet roofing. BI01010001010000000000000515BI0100001214 614.556 sqm
103 86 Dismantling wood work. Wrought framed and fixed in frames other frames and trusses of span upto 10 metres and above and stacking the serviceable materials in specified manners and disposal of un-serviceable materials in all lead & lift upto the site arranged by the contractor and as per the direction of Engineer Incharge. No additional rates will be paid towards dumping charges and disposal of surplus materials. BI01010001010000000000000515BI0100001215
104 86.1 Sectional area average 40 Sq.cm. or over. BI01010001010000000000000515BI0100001216 15.12 cum
105 87 Dismantling steel work upto span of 10 metres and above height between ridge and floor level upto 5 metres and above in single sections including dismantling and stacking the materials upto all lead and lift through manual and mechanical means in all lead & lift upto dumping site arranged by the contractor. No additional rates will be paid towards dumping charges and disposal of unserviceable materials. BI01010001010000000000000515BI0100001217
106 87.1 Channels, angles, tees and flats:- BI01010001010000000000000515BI0100001218 9714.9 Kg
107 88 Dismantling doors, windows and clerestory windows, ventilators etc. (wood or steel) shutters including chowkhats, architraves, hold fasts and other attachments etc. complete and stacking the disposal of serviceable materials in proper manner in all lead & lift in upto the dumping site arranged by the contractor. No additional rates/amount will be paid towards disposal and dumping charges. BI01010001010000000000000515BI0100001219
108 88.1 Exceeding 3 Sq.M. in area BI01010001010000000000000515BI0100001220 84 Each
109 89 Providing and fixing to wall ceiling and floor galvanised mild steel tube ( medium grade) tube fittings and clamps including making good the wall ceiling and floors including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001221
110 89.1 15mm BI01010001010000000000000515BI0100001222 129.95 Rmt
111 89.2 20mm BI01010001010000000000000515BI0100001223 528.26 Rmt
112 89.3 25mm BI01010001010000000000000515BI0100001224 313.43 Rmt
113 89.4 32mm BI01010001010000000000000515BI0100001225 13.8 Rmt
114 89.5 40mm BI01010001010000000000000515BI0100001226 117.8 Rmt
115 89.6 50mm BI01010001010000000000000515BI0100001227 177.3 Rmt
116 90 Providing and fixing extension nipple of approved quality 15 mm (ISI Mark) Heavy duty including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001228 93 Each
117 91 Providing and fixing sand cast iron span spigot and socket soil, waste and ventilating pipes (ISI Mark) of approved make (lead caulked joints to be measured and paid for separately) including carriage of material in all leads and lifts.. BI01010001010000000000000515BI0100001229
118 91.1 75mm nominal diameter BI01010001010000000000000515BI0100001230 181.25 Rmt
119 91.2 100mm nominal diameter BI01010001010000000000000515BI0100001231 198.65 Rmt
120 92 Providing and fixing sand cast iron spun fitting and accessories of approved make (ISI Mark) including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001232
121 92.1 C.I. plain bend\n100 mm diameter BI01010001010000000000000515BI0100001233 30 Each
122 93 Providing and fixing heel rest bend of approved make (ISI Mark) including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001234
123 93.1 75 mm diameter BI01010001010000000000000515BI0100001235 9 Each
124 93.2 100 mm diameter BI01010001010000000000000515BI0100001236 10 Each
125 94 Providing and fixing single equal plain junction of required degree with access door, of approved make (ISI Mark) installation rubber washer 3mm thick nuts and bolts complete including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001237
126 94.1 75x75x75 BI01010001010000000000000515BI0100001238 8 Each
127 94.2 100x100x100 BI01010001010000000000000515BI0100001239 9 Each
128 95 Providing and fixing CI cowl of approved make (ISI Mark) including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001240
129 95.1 75 mm diameter BI01010001010000000000000515BI0100001241 9 Each
130 95.2 100 mm diameter BI01010001010000000000000515BI0100001242 10 Each
131 96 Single equal branch of required degree Plain of approved make (ISI Mark) including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001243
132 96.1 75 mm diameter BI01010001010000000000000515BI0100001244 5 Each
133 96.2 100 mm diameter BI01010001010000000000000515BI0100001245 10 Each
134 97 Providing and fixing M.S. Clamp of approved quality (Heavy duty) including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001246
135 97.1 75 mm diameter BI01010001010000000000000515BI0100001247 43 Each
136 97.2 100 mm diameter BI01010001010000000000000515BI0100001248 48 Each
137 98 Providing and fixing C.I. floor trap of self cleaning design with screwed down or hinged grating with or without vent arm of approved make (ISI Mark) complete including cost of cutting and making good the walls and floors (100mm) including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001249 73 Each
138 99 Providing and laying Stone ware (ISI mark) half glazed pipe of approved make including carriage of material upto leads and lifts and as per direction of Engineer Incharge. BI01010001010000000000000515BI0100001250
139 99.1 100mm BI01010001010000000000000515BI0100001251 34.75 Rmt
140 99.2 150mm BI01010001010000000000000515BI0100001252 87.8 Rmt
141 99.3 200mm BI01010001010000000000000515BI0100001253 156 Rmt
142 100 Providing and fixing stone ware gully trap grade ‘A’ of approved make complete with CI grating brick masonry chamber in cement mortar 1:4 and water tight C.I. cover with frame of 300mmx300mmx300mm size (inside) the weight of cover to be not less than 4.53 Kg and frame to be not less than 2.72 kg square mouth trap 100mx100mm size P-Type including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001254 16 Each
143 101 Providing and Laying cement concrete pipe NP2 (burried conducts) of approved make on first class bedding of granular material base including fixing collar with cement sand morter 1:2 but excluding excavation, protection works, backfilling, concrete and masonry work in head wall and parafits including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001255 223.5 Rmt
144 102 Making connection of drain or sewere line with existing main hole including breaking into and making good the walls floors with cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20mm nominal size) cement plaster on both side with cement mortar 1:4 ( 1 cement : 3 sand) finished with a floating coat of a neat cement and making necessary channels with cement concrete 1:2:4 for the drain complete as per the requirement and direction of the Engineer Incharge. For pipes 100mmx250mm internal diameter. BI01010001010000000000000515BI0100001256 1 Each
145 103 Constructing manhole with R.C.C. top slab in I :2:4 mix in I cement:2 sand: 4 graded stone aggregate 20 mm nominal size), foundation concrete 1 : 4: 8 (I cement: 4 sand: 8 graded stone aggregate 40 mm nominal size), inside plastering 15 mm thick with cement mortarl:4 (I cement: 4 sand) finished with a floating coat of neat cement and making channels in cement concrete I :2:4 mix (I camet: 2 sand: 4 graded sit stone aggregate 20 mm . nominal size) finished smooth complete including curing & testing etc. complete as per design, specification and direction of the Engineer Incharge and carriage of materials in all lead & lift. BI01010001010000000000000515BI0100001257
146 103.1 Inside size 800 mm x 800 mm and 500 mm deep including C.1. cover with: frame. (Light duty single seal: patenn I) 455 mm x 610 mm internal dimensions total weight of cover and frame to be not less than 38 kg. (weight of cover 23 kg. and weight of frame 15kg. BI01010001010000000000000515BI0100001258
147 103.2 With 200 mm thick walls of brick masonry using common burnt clay building bricks in cement mortar 1:4 (I cement: 4 sand). BI01010001010000000000000515BI0100001259 23 Each
148 103.3 in side size 800x800mm and 1.00 metre deep including C.I. Cover with frame (light duty single seat pattern) 450x610mm internal dimensions total weight of cover and frame to be not less than 38kg. (weight of cover 23kg. And weight of frame 15kg.) BI01010001010000000000000515BI0100001260
149 103.4 with 200mm thick wall of brick masonry using commone burnt clay building bricks in cement mortar 1:4(1 cement : 4 sand). BI01010001010000000000000515BI0100001261 20 Each
150 104 Providing and fixing vitreous wash down Cera Make cat no s1012136 or equivalent white colour studio set along with C.P. JET ,SEAT COVER, CISTERN and twin flushing valves etc. complete in all respect, water closet ( European Type - WC pan) with integral 'p' or 's' trap including jointing the trap with soil pipe in cement mortar 1:1 ( one cement, one sand) (with cistern, seat cover and flush fitting) Star White including carriage of materials upto all leads and lifts and as per direction of Engineer in charge. BI01010001010000000000000515BI0100001262 30 Each
151 105 Providing and fixing wash basin with pedestal Cera Cat. No. s2040103,550x400mm or equivalent including carriage of materials up to all leads and lifts and as per direction of Engineer in charge. BI01010001010000000000000515BI0100001263 28 Each
152 106 Providing and fixing steel sink of Cera Make cat no. B4621102 or equivalent of approved design size: a) 610mmx455mmx225mm including carriage of materials up to all leads and lifts and as per direction of Engineer Incharge.(Darby lite 24" x 18") BI01010001010000000000000515BI0100001264 7 Each
153 107 Providing and fixing automatic Urinal (Star white),320x300x525mm Cera Make Cat. No. 54010102, or equivalent including carriage of material to all leads and lifts and as per direction of Engineer Incharge. BI01010001010000000000000515BI0100001265 7 Each
154 108 Providing and fixing white viterous china division plate for urinal of size 900 mm X 320 mm X 720 mm complete( Cera make Cat. No. 54090101 Division plate or equivalent) and as per specification , drawing and including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001266 7 Each
155 109 Providing and fixing CP Brass Auto Closing concealed Urinal Flush Valve with Flange complete of approved quality & series including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001267 7 Each
156 110 Providing and fixing 15mm nominal size CP brass angle valve/ Stop Cock Cera Make Cat No. F1014201or equivalent with flange including carriage of material to all leads and lifts and as per direction of Engineer Incharge. BI01010001010000000000000515BI0100001268 93 Each
157 111 Providing and fixing C.P. Paper Holder Cera make Cat No. F5007110 or equivalent including carriage of material up to all leads and lifts and as per direction of Engineer Incharge. BI01010001010000000000000515BI0100001269 30 Each
158 112 Providing and fixing C.P. brass towel rail complete with C.P. brass brackets (Cera or equivalent) F5006103 fixed to wooden plugs with C.P. brass screws including carriage of materials within all leads and lifts. BI01010001010000000000000515BI0100001270 2 Each
159 113 Providing and fixing 15mm nominal size Pillar cock (Cera Make Cat. No. F2008101) or equivalent with aerator including carriage of material upto all leads and lifts. BI01010001010000000000000515BI0100001271 56 Each
160 114 Providing and fixing over head shower of Cera Make Catalog No. F7020102 approved quality including carriage of material to all leads and lifts and as per direction of Engineer Incharge. BI01010001010000000000000515BI0100001272 2 Each
161 115 Providing and fixing C.P. Grab bar Cera Make Catalog No. B2210105 or equivalent 350mm long including carriage of material upto all leads and lifts. BI01010001010000000000000515BI0100001273 6 Each
162 116 Providing and fixing Gate valve with wheel of approved quality with wheel (ISI Mark, heavy duty) including carriage of material to all leads and lifts and as per direction of Engineer Incharge. BI01010001010000000000000515BI0100001274
163 116.1 15mm BI01010001010000000000000515BI0100001275 25 Each
164 116.2 20mm BI01010001010000000000000515BI0100001276 29 Each
165 116.3 25mm BI01010001010000000000000515BI0100001277 23 Each
166 116.4 32mm BI01010001010000000000000515BI0100001278 1 Each
167 116.5 40mm BI01010001010000000000000515BI0100001279 4 Each
168 116.6 50mm BI01010001010000000000000515BI0100001280 5 Each
169 117 Providing and fixing brass ball valve of approved quality (ISI Mark, heavy duty) including carriage of material to all leads and lifts and as per direction of Engineer Incharge. BI01010001010000000000000515BI0100001281
170 117.1 15mm BI01010001010000000000000515BI0100001282 3 Each
171 117.2 20mm BI01010001010000000000000515BI0100001283 5 Each
172 118 Providing and fixing CP Grating 100mm including carriage of material upto all leads and lifts. Chilly make. BI01010001010000000000000515BI0100001284 45 Each
173 119 Providing and fixing PVC connections pipe with brass unions 45cm length 15 mm nominal bore of approved quality including carriage of material in all leads and lifts BI01010001010000000000000515BI0100001285 93 Each
174 120 Providing and fixing P.V.C. waste pipe for wash basin and sink of approved quality including carriage of material upto all leads and lifts and as per direction of Engineer Incharge. (32mm) BI01010001010000000000000515BI0100001286 7 Each
175 121 Providing and fixing bottel trap with fully casted body (with integral partition ) 32mm with 190 and 125mm long connecting pipes and wall flang Cera make Cat. No.F8060101 or equivalent including carriage of material upto all leads and lifts and as per the direction of Engineer -in-charge BI01010001010000000000000515BI0100001287 35 Each
176 122 Providing and fixing 500 x 700 mmX5mm Readymade mirror of superior glass mounted on wodden plugs Cera make cat no B3510112 or equivalent with C.P. brass screw including carriage of material upto all leads and lifts and as per direction of Engineer Incharge BI01010001010000000000000515BI0100001288 22 Each
177 123 Providing and fixing Corner Glass shelves ( medium) Cera make cat no F5005102 including carriage of material upto all leads and lifts and as per direction of Engineer Incharge BI01010001010000000000000515BI0100001289 2 Each
178 124 Providing, placing and fixing on terrace (at all floor levels) polyethylene water storage tank IS :12701 marked,(Sintex or equivalent double layer) weight not less than 64 kg with cover and suitable locking arrangement, and making necessary holes for inlet, outlet and overflow pipe, and with fitting complete, (UV protected, rounded corneer make with month and year of manufacturer extra ribs on top and horizontally for greater strength) and as per specification, drawings including carriage of material upto all leads and lifts and as per the direction of Engineer -in-charge.\nSintex make BI01010001010000000000000515BI0100001290
179 124.1 2000 ltrs BI01010001010000000000000515BI0100001291 3 Each
180 124.2 1000 ltrs BI01010001010000000000000515BI0100001292 4 Each
181 124.3 500 ltrs BI01010001010000000000000515BI0100001293 3 Each
182 125 Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit with modular switch, modular plates, suitable G.I. box and earthling the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required.(Legrand/Havell,s/North-west make) including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001294
183 125.1 Group A. BI01010001010000000000000515BI0100001295 17 point
184 125.2 Group C. BI01010001010000000000000515BI0100001296 347 point
185 126 Wiring for twin control light point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit, with 2-way modular switch, modular plates, suitable G.I. box and earthling the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required..(Legrand/Havell,s/North-West make) including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001297
186 126.1 Group C. BI01010001010000000000000515BI0100001298 11 point
187 127 Supplying and fixing stepped type Modular fan regulator on the existing modular box including making connections etc. as required. (Legrand/Havell,s/North-West make) including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001299 2 each
188 128 Supplying and fixing following rating Modular switch /socket in the existing switch box / cover plate including connections etc. including carriage of materials in all lead & lift and direction of the Engineer Incharge. (Legrand/Havell,s/North-West make) BI01010001010000000000000515BI0100001300
189 128.1 S.P. 5/ 6 Amps one way Modular switch. BI01010001010000000000000515BI0100001301 84 each
190 128.2 5 pin, 5/ 6 Amps Modular socket outlet. BI01010001010000000000000515BI0100001302 84 each
191 129 Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 5 pin 5/6 amps modular socket outlet and 5/6 amps, modular switch, connections etc. as required including carriage of materials in all lead & lift and direction of the Engineer Incharge. (Legrand/Havell,s/North-West make) BI01010001010000000000000515BI0100001303 84 each
192 130 Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps, modular switch, connections etc. as required including carriage of materials in all lead & lift and direction of the Engineer Incharge. (Legrand/Havell,s/North-West make) BI01010001010000000000000515BI0100001304 89 each
193 131 Supplying and fixing bakelite batten holder including connections etc. as required including carriage of materials in all lead & lift and direction of the Engineer Incharge. (Anchor, Havells,L&T,Goldmedal) BI01010001010000000000000515BI0100001305 49 each
194 132 Supplying and drawing following size of PVC insulated ,heat resistant, flame retardent (HRFR) and low smoke singlecore (flexible) copper condustor cable in the existing surface / recessed, steel / PVC conduit as required including carriage of materials in all lead & lift and direction of the Engineer Incharge. (Havell,s/Plaza/Finolex/RR Cable) BI01010001010000000000000515BI0100001306
195 132.1 1X1.5 SQMM BI01010001010000000000000515BI0100001307 855 Meter
196 132.2 2X1.5 SQMM BI01010001010000000000000515BI0100001308 1055 Meter
197 133 Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No. HRFRLS/PVC insulated single core copper conductor cable of same size for earthling as required including carriage of materials in all lead & lift and direction of the Engineer Incharge. (Havell,s/Plaza/Finolex/RR Cable) BI01010001010000000000000515BI0100001309
198 133.1 2x1.5 Sq. mm. BI01010001010000000000000515BI0100001310 672 Meter
199 133.2 2x4.0 Sq. mm. BI01010001010000000000000515BI0100001311 1338 Meter
200 133.3 2x6.0 Sq. mm. BI01010001010000000000000515BI0100001312 308 Meter
201 133.4 4 x 6.0 + 2 x 6.0 Sq. mm. BI01010001010000000000000515BI0100001313 350 Meter
202 133.5 4 x 10 + 2 x 10 Sq. mm. BI01010001010000000000000515BI0100001314 255 Meter
203 134 Supplying and fixing of following sizes of PVC conduit along with the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required including carriage of materials in all lead & lift and direction of the Engineer Incharge. (D-Plast,Polyfit) BI01010001010000000000000515BI0100001315
204 134.1 20 mm. dia BI01010001010000000000000515BI0100001316 610 Meter
205 134.2 25 mm. dia BI01010001010000000000000515BI0100001317 1389 Meter
206 135 Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required including carriage of materials in all lead & lift and direction of the Engineer Incharge. (Legrand/Havell,s/North-west make) BI01010001010000000000000515BI0100001318
207 135.1 Single pole. Cat-A. BI01010001010000000000000515BI0100001319 253 each
208 136 Supplying and erection of40/50/63 amp.. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required including carriage of materials in all lead & lift and direction of the Engineer Incharge. (Legrand/Havell,s/North-West make) BI01010001010000000000000515BI0100001320
209 136.1 Double pole. Cat-A. BI01010001010000000000000515BI0100001321 21 each
210 136.2 Triple Pole and neutral Cat-A BI01010001010000000000000515BI0100001322 18 each
211 137 Supplying and fixing following rating, Four pole (three phase & neutral) 415volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required including carriage of materials in all lead & lift and direction of the Engineer Incharge. (Legrand/Havell,s/North-West make) BI01010001010000000000000515BI0100001323
212 137.1 40 Amps. Cat-A. BI01010001010000000000000515BI0100001324 4 each
213 137.2 63 Amps. Cat-A. BI01010001010000000000000515BI0100001325 12 each
214 138 Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthling etc. as required including carriage of materials in all lead & lift and direction of the Engineer Incharge. (Legrand/Havell,s/North-West make) BI01010001010000000000000515BI0100001326
215 138.1 Double door-6 way BI01010001010000000000000515BI0100001327 1 each
216 138.2 Double door-12way BI01010001010000000000000515BI0100001328 2 each
217 139 Supplying and fixing of following way, triple pole and neutral sheet steel MCB distribution board, 415volts, on surface / recess, with provision for 4-pole MCB/RCCB/RCBO as incomer and SP MCBs as outgoing,complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthling etc. as required including carriage of materials in all lead & lift and direction of the Engineer Incharge. (Legrand/Havell,s/North-West make) BI01010001010000000000000515BI0100001329
218 139.1 Double door-4 way (8+12),horizontal type BI01010001010000000000000515BI0100001330 7 each
219 139.2 Double door-6 way (8+18),horizontal type BI01010001010000000000000515BI0100001331 8 each
220 139.3 Double door-8 way (8+24,horizontal type BI01010001010000000000000515BI0100001332 1 each
221 140 Providing, installing, testing and commissioning of ceiling fan and regulator, including wiring, the down road of standard length(upto 30 Cm.) with 1.5 Sq.mm. PVC insulated copper conductor single core cable etc. as required including carriage of materials in all lead & lift and direction of the Engineer Incharge. (Usha/Baja/Havells/Khaitan make) BI01010001010000000000000515BI0100001333
222 140.1 Ceiling Fan 1200 mm sweep, category-A BI01010001010000000000000515BI0100001334 1 each
223 140.2 Ceiling Fan 1400 mm sweep, category-A BI01010001010000000000000515BI0100001335 1 each
224 141 Providing and installation of exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required including carriage of materials in all lead & lift and direction of the Engineer Incharge. (Usha/Baja/Havells/Khaitan make) BI01010001010000000000000515BI0100001336
225 141.1 Exhaust Fan, Light duty, 300 mm sweep BI01010001010000000000000515BI0100001337 22 each
226 141.2 Exhaust Fan, Heavy duty, 300 mm sweep BI01010001010000000000000515BI0100001338 5 each
227 142 Providing and installation of stationary storage type Electric water heater (Geyser) of various sizes by means of Expansion-bolts with nuts and washers, including embedding of expansion-bolts in the wall, providing and fixing of Non-return valve, Dead weight safety valve, 2 No C.P. connection rods 18" long, making good the damages, electrical connections, safety valve connections, testing and commissioning etc. as required including carriage of materials in all lead & lift and direction of the Engineer Incharge. (Bajaj/Recold/Sparehot/Havell,s). BI01010001010000000000000515BI0100001339
228 142.1 15 Liter capacity water heater (Cat-A) BI01010001010000000000000515BI0100001340 3 each
229 142.2 35 Liter capacity water heater (Cat-A) BI01010001010000000000000515BI0100001341 10 each
230 143 Supplying & fixing of G.I. modular boxes of following sizes along with modular base and cover plate for modular switches in recess as required including carriage of materials in all lead & lift and direction of the Engineer Incharge. (Legrand/Havell,s/North-West make) BI01010001010000000000000515BI0100001342
231 143.1 2 modules (78mmx78mmx50mm) BI01010001010000000000000515BI0100001343 43 each
232 144 Supplying and fixing following rating Modular switch /socket in the existing switch box / cover plate including connections etc. as required including carriage of materials in all lead & lift and direction of the Engineer Incharge. (Legrand/Havell,s/North-West make) BI01010001010000000000000515BI0100001344
233 144.1 Telephone socket BI01010001010000000000000515BI0100001345 29 each
234 144.2 TV. Socket outlet, modular. BI01010001010000000000000515BI0100001346 14 each
235 145 Extra for fixing the louvers/shutters complete with frame for exhaust fans of all sizes as required including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001347 14 each
236 146 Supplying and drawing following pair of Fire Retardant, PVC insulated 0.5 sq.mm. (FR-Flexible) copper conductor, flat, unarmoured, telephone cable in existing surface / recessed, steel / PVC conduit as required including carriage of materials in all lead & lift and direction of the Engineer Incharge. (Havell,s/Plaza/Finolex/RR Cable) BI01010001010000000000000515BI0100001348
237 146.1 1 Pair BI01010001010000000000000515BI0100001349 1715 Each
238 147 Supplying and drawing co-axial TV cable,RG-6 grade,0.7mm (75 Ohms) copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface / recessed, steel / PVC conduit as required including carriage of materials in all lead & lift and direction of the Engineer Incharge. (Havell,s/Plaza/Finolex/RR Cable) BI01010001010000000000000515BI0100001350 735 Meter
239 148 Supplying and fixing Ding-Dong / Electronic musical bell, suitable for D.C./A.C. single phase,230 volts complete as required including carriage of materials in all lead & lift and direction of the Engineer Incharge. (legrand make) BI01010001010000000000000515BI0100001351 11 each
240 149 Earthling with copper earth plate 600 mmx600 mmx 3 mm thick, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as required including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001352 38 Set
241 150 Extra for using salt and charcoal for G.I. or copper plate earth electrode complete as required including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001353 38 Set
242 151 Providing and fixing of lightning conductor finial, made of 25 mm dia. 300 mm long copper tube, having single prong at top, with 85 mm dia 3 mm thick copper base plate including holes etc. complete as required including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001354 8 each
243 152 Supplying and fixing copper tape 20mmx3mm thick on parapet or surface of wall for lightning conductor as required including carriage of materials in all lead & lift and direction of the Engineer Incharge. ( for horizontal run) BI01010001010000000000000515BI0100001355 370 Meter
244 153 Supplying and fixing copper tape 20mmx3mm thick on parapet or surface of wall for lightning conductor as required including carriage of materials in all lead & lift and direction of the Engineer Incharge. ( for vertical run) BI01010001010000000000000515BI0100001356 294 Meter
245 154 Supplying and fixing 25mmx5mm coper strip on surface or in recess for earth connections etc.as required including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001357 230 Meter
246 155 Supplying and laying 8 SWG copper wire at 0.50 mtr. On surface or in recess for loop earthling along with existing surface/recess/submain wiring/cable as required as required including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001358 318 Meter
247 156 Supplying and fixing 32mm x 6mm coper strip on surface or in recess for earth connections etc.as required including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001359 136 Meter
248 157 Providing and laying of one No. aluminum conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade direct in ground; to be laid 1 meter below the ground level including excavation and refilling the trench etc.as required, but excluding sand cushioning and protective covering:- (Havell,s/ Polycab/ phenolex make as approved by site Incharge) including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001360
249 157.1 Armoured cable 10 sq. mm (2 core) BI01010001010000000000000515BI0100001361 90 R.Mtr.
250 157.2 Armoured cable 10 sq. mm (4core) BI01010001010000000000000515BI0100001362 480 R.Mtr.
251 157.3 Armoured cable 16 sq. mm (4 core) BI01010001010000000000000515BI0100001363 185 R.Mtr.
252 157.4 Armoured cable 95 sq. mm (3.5 core) BI01010001010000000000000515BI0100001364 150 R.Mtr.
253 157.5 Armoured cable 300 sq. mm (3.5 core) BI01010001010000000000000515BI0100001365 120 R.Mtr.
254 157.6 Armoured cable 400 sq. mm (3.5 core) BI01010001010000000000000515BI0100001366 80 R.Mtr.
255 158 Supplying and erection of Galvanized Iron (G.I.) pipe pole 'A' quality of suitable length and dia. 4.47 mm thickness, including fixing up to a given depth below G/L.The hole of excavation about 30 cm dia. and given depth to be filled in up to 15 cm below G/L with 1:3:6 cement concrete and there above plinth with 1:2:4 cement concrete up to a height of 45 cm from G/L. The radial thickness of the plinth above G/L should not be less than 6.35 cm and sufficient to completely flush a 2way single door MCB DB WITH 6 Amp. MCB, the outer surface of the plinth to be finished with 1:3 cement plaster 6 mm thick, including painting of pole with two coats of approved color, brand and manufacture of paint over a priming coat complete in all respects as required including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001367
256 158.1 4 Meter long having nominal bore dia. 65 mm planting depth 80 cm with pit depth 95 cm. BI01010001010000000000000515BI0100001368 20 each
257 159 Supplying and fixing of LED post top BLPTSP 25W NW LED Bajaj make in spherical shape polycarbonate diff user with IP65 protection., complete with accessories including connections as required including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001369
258 159.1 LED post top BLPTSP 25W NW LED Bajaj make BI01010001010000000000000515BI0100001370 20 each
259 160 Supplying and erection of 3 stepped steel tubular swaged and welded pole of suitable length and dia. to be fixed up to a required planting depth below G/L in a hole of excavation about 30 cm dia. and of suitable depth, to be filled in up to 15 cm below G/L with 1:3:6 cement concrete and there above plinth with 1:2:4 cement concrete up to a height of 45 cm from G/L. The radial thickness of the plinth above G/L should not be less than 6.35 cm and sufficient to completely flush a 180 mmx100 mmx 45 mm deep, glass filled Nylan F.R.grade box for housing a 16 Amp. MCB, the outer surface of the plinth to be finished with 1:3 cement plaster 6 mm thick, the fuse-box shall have a water tight cover, including painting of pole with two coats of approved color, brand and manufacture of paint over a priming coat complete in all respects as required including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001371
260 160.1 Overall length 8.5 meter, with planting depth 1.5 m, length of sections 4 m, 2.25m and 2.25m (bottom, middle and top respectively), outer dia and thickness of sections 168.3mmx4.5mm, 139.7mmx4.5mm and 114.3mmx3.25mm (bottom, middle and top respectively) with approximate weight 126 Kg BI01010001010000000000000515BI0100001372 21 each
261 161 Providing and fixing fan box (nominal size) complete in all respect as required including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001373 2 each
262 162 Providing and fixing of wall fan 400mm sweep havells make swing premia wall fan The work involves assembly, fixing, connecting, commissioning and testing of the wall fan in complete respect including carriage of materials in all lead & lift and direction of the Engineer Incharge. (Usha/Baja/Havells/Khaitan make) BI01010001010000000000000515BI0100001374 6 each
263 163 Supply, installation, testing & commissioning of MAIN L.T PANEL - 1 Consisting of following panels, incomer & outgoing feeders, copcitor Bank Feeders, distribution panel etc. including packing, forwarding, Munal & mechanical carriage and installation charger including civil work complete as per the direction of the Engineer Incharge. BI01010001010000000000000515BI0100001375 1 each
264 163.1 NOTES FOR ALL PANELS :-\nAll MCCB should be Icu = Ics = 100% .\nPanel G.A, S.L.D and Control Wiring (Autocad Format) will be approved by Electrical Consultant before manufacturing of panel.\nApproved Make of ACB are ABB - E Max OR L&T - U Power Omega.\nApproved Make of MCCB are ABB - T Max OR L&T - D Sine.\nControl wire for indicators & instruments should be 1.5mm² copper FRLS flexible.\nWire for CT's should be 2.5mm² copper FRLS flexible.\nVoltage Monitoring Relay should be 3 Phase 4 Wire. BI01010001010000000000000515BI0100001376
265 163.2 Supply, assembly, erection, testing and commissioning of Indoor type floor mounted free standing dust and vermin proof panel with IP-52 protection fabricated out of suitable sized angle iron and flats and covered with 2mm thick CRCA sheet of standard/approved make duly pretreated in seven tank process for de-greasing , de-rusting & phosphated painted with 2 coats of primer paint then the panel surface shall be finished/rubbed and then painted with final coat of epoxy based powder coated Paint.Panel shall be compartmentrised with rubber gasketed hinged door with lock. BI01010001010000000000000515BI0100001377
266 163.3 Panel shall be having Front operated , busbar chamber and switchgear compartments.The bus bar shall be of electrolytic aluminum .firmly fixed on DMC/SMC insulators and duly covered with heat shrink sleeves R.Y.B.N.. The Neutral Bus should have the capacity equal to phase bus bar. The wiring shall be of copper FRLS of adequate capacity and connected to the terminals with proper rating lugs & cable clamping support system. Extended busbar links/ terminals to be provided for connecting cables.Air ventillation breathers to be provided for heat dissipation. Suitable sized knock-out holes for cable glands shall be provided. All Interlocking and Wiring as per respective Schematic Drawing of the panel with the following equipments / insruments. BI01010001010000000000000515BI0100001378
267 163.4 Paint shall be epoxy based DANCOT/Asian make of Siemens Grey shade or as per approved by Engineering Incharge. Each Compartment shall be numbered / lettered as per the approved drg. affixing MV Danger plate at suitable intervals/locations. The lifting hooks be provided for all panels.The panel shall be in the possession of State Electricity Board ,hence the sealing arrangement for all openings shall have to be made as per rules & regulations of Electricity Board. The panel shall be as per IS specifications & as required complete in all respect as per approved drawing, design and direction of the Engineer Incharge as per details given below:-. BI01010001010000000000000515BI0100001379
268 163.5 Incomer Feeder - 1 For 630 kVA Transformer\n1250A, ACB, 4Pole, 50KA with Microprocessor based LSING protection , Electrically Operated Draw out type, closing / Trip coil 230V AC, spring charging motor 220V AC, - 1 No.\nUnder Voltage Release 220V AC - 1 No.\nPhase Indicating Lamps, Red,Yelow Led Type- 2 No.\nPhase Indicating Lamps, Blue Led Type - 1 No.\nControl MCB, 6A, SP, 10KA - 7 No.\nNeutral Link, 20A - 1 No.\nEnergy Analyser EM 6400 - 1 No.\nIndicating Lamps, On.Off.Trip Led Type - 3 No.\nTNC switch, 10A, - 1 No.\nAuto / Manual selector switch - 1 No.\nCT,s 1200/5A, class 1, 15VA, Tapewound - 3 No.\nCT Shorting Links - 4 No.\nVoltage Monitoring Relay - 1 No.\nAuxiliary Contactor 2NO+2NC - 1 No.\nOn Delay Timer 0 - 60sec. - 1 No. BI01010001010000000000000515BI0100001380
269 163.6 Incomer Feeder - 2 For 625 kVA D.G SET\n1250A, ACB, 4Pole, 50KA with Microprocessor based LSING protection , Electrically Operated Draw out type, closing / Trip coil 230V AC, spring charging motor 220V AC, - 1 No.\nUnder Voltage Release 220V AC - 1 No.\nPhase Indicating Lamps, Red,Yelow Led Type- 2 No.\nPhase Indicating Lamps, Blue Led Type - 1 No.\nControl MCB, 6A, SP, 10KA - 7 No.\nNeutral Link, 20A - 1 No.\nEnergy Analyser EM 6400 - 1 No.\nIndicating Lamps, On.Off.Trip Led Type - 3 No.\nTNC switch, 10A, - 1 No.\nAuto / Manual selector switch - 1 No.\nCT,s 1200/5A, class 1, 15VA, Tapewound - 3 No.\nCT Shorting Links - 3 No.\nVoltage Monitoring Relay - 1 No.\nAuxiliary Contactor 2NO+2NC - 1 No.\nOn Delay Timer 0 - 60sec. - 1 No.\nPush Button Stop. Start - 2 No.\nControl MCB, 6A, DP, 10KA - 1 No.\nAuxiliary Contactor 2NO+2NC, 24V DC - 1 No.\nBattery Charger 220V AC / 24V DC - 1 No.\nVoltmeter Digital 0 - 30V DC, 96mm x 96mm - 1 No.\nAmmeter Digital 0 - 30A DC, 96mm x 96mm - 1 No.\nAuto / Manual Selector switch - 1 No.\nControl MCB, 6A, DP, 10KA - 2 No. BI01010001010000000000000515BI0100001381
270 163.7 NOTE :- AMF System and Interlocking system between Transformer Incomer and D.G Set incomer wiring in Main L.T Panel -1 is in Panel manufacturer Scope, including all Other miscellaneous items. No extra cost will be paid. BI01010001010000000000000515BI0100001382
271 163.8 Outgoing Feeders\n1000 A, MCCB, 4 Pole, 50KA with Thermal Megnatic Release, o/c.s/c. protection with Spreaders Terminal, Phase Barriers, Extended Rotary Operating Handle - 1 Set\nIndicating Lamps, On.Off. Trip Led Type - 3 Nos.\nControl MCB, 6A, SP, 10KA - 1 No.\nTrip Alarm Contact - 1 No.\n200 A, MCCB, 4 Pole, 50KA with Thermal Megnatic Release, o/c.s/c. protection with Spreaders Terminal, Phase Barriers, Extended Rotary Operating Handle - 3 Set\nIndicating Lamps, On.Off. Trip Led Type - 9 Nos.\nControl MCB, 6A, SP, 10KA - 3 No.\nTrip Alarm Contact - 3 No.\n100 A, MCCB, 4 Pole, 50KA with Thermal Megnatic Release, o/c.s/c. protection with Spreaders Terminal, Phase Barriers, Extended Rotary Operating Handle - 2 Set\nIndicating Lamps, On.Off. Trip Led Type - 6Nos.\nControl MCB, 6A, SP, 10KA - 2 No.\nTrip Alarm Contact - 2 No.\n4 POLE MCB 63 AMP, C CURVE, 10 KA - 12 NOS. BI01010001010000000000000515BI0100001383
272 163.9 Capacitor Bank Feeders\n200kVAR APFC Panel comprising of Main Incomer 400 Amp 50kA TPN MCCB with 400 Amp, 4 Pole, Power Contactor for interloking with D.G Incomer and Capacitor Feeder (Electrical Interloking should be provide between the D.G Supply incomer and Capacitor bank. Capacitor will Run only, when Electricity supply is ON and when the D.G supply is On, Capacitor Panel will not Run.\nOutgoing of Capacitor Feeder - 125 Amp, TP, MCCB with 125 Amp Capacitor Duty Contactor with MPP type Capacitor rated 50kVAR x 2nos. AND 63 Amp, TP, MCCB with 60 Amp Capacitor Duty Contactor with MPP type Capacitor rated 25kVAR x 4 nos, 8 stage APFC relay, A/M switch, ON/OFF PBs, ON/OFF indication lamps of L&T - Make - 1 Set Complete BI01010001010000000000000515BI0100001384
273 164 Supply, installation, testing & commissioning of MAIN L.T PANEL - 2 Consisting of following panels, incomer & outgoing feeders, copcitor Bank Feeders, distribution panel etc. including packing, forwarding, Munal & mechanical carriage and installation charger including civil work complete as per the direction of the Engineer Incharge. BI01010001010000000000000515BI0100001385 1 each
274 164.1 NOTES FOR ALL PANELS :-\nAll MCCB should be Icu = Ics = 100% .\nPanel G.A, S.L.D and Control Wiring (Autocad Format) will be approved by Electrical Consultant before manufacturing of panel.\nApproved Make of ACB are ABB - E Max OR L&T - U Power Omega.\nApproved Make of MCCB are ABB - T Max OR L&T - D Sine.\nControl wire for indicators & instruments should be 1.5mm² copper FRLS flexible.\nWire for CT's should be 2.5mm² copper FRLS flexible. BI01010001010000000000000515BI0100001386
275 164.2 Supply, assembly, erection, testing and commissioning of Outdoor type floor mounted free standing dust and vermin proof panel with IP-54 protection fabricated out of suitable sized angle iron and flats and covered with 2mm thick CRCA sheet duly pretreated in seven tank process for de-greasing , de-rusting & phosphated painted with 2 coats of primer paint then the panel surface shall be finished/rubbed and then painted with final coat of epoxy based powder coated Paint.Panel shall be compartmentrised with rubber gasketed hinged door with lock. BI01010001010000000000000515BI0100001387
276 164.3 Panel shall be having Front operated , busbar chamber and switchgear compartments.The bus bar shall be of electrolytic aluminum .firmly fixed on DMC/SMC insulators and duly covered with heat shrink sleeves R.Y.B.N.. The Neutral Bus should have the capacity equal to phase bus bar. The wiring shall be of copper FRLS of adequate capacity and connected to the terminals with proper rating lugs & cable clamping support system. Extended busbar links/ terminals to be provided for connecting cables.Air ventillation breathers to be provided for heat dissipation. Suitable sized knock-out holes for cable glands shall be provided. All Interlocking and Wiring as per respective Schematic Drawing of the panel with the following equipments / insruments. BI01010001010000000000000515BI0100001388
277 164.4 Paint shall be epoxy based DANCOT/Asian make of Siemens Grey shade or as per approved by Engineering Incharge. Each Compartment shall be numbered / lettered as per the approved drg. affixing MV Danger plate at suitable intervals/locations. The lifting hooks be provided for all panels.The panel shall be in the possession of State Electricity Board ,hence the sealing arrangement for all openings shall have to be made as per rules & regulations of Electricity Board. The panel shall be as per IS specifications & as required complete in all respect as per details given below:-. BI01010001010000000000000515BI0100001389
278 164.5 Incomer Feeder From LT Panel -1\n200 A, MCCB, 4 Pole, 36KA with Thermal Megnatic Release, o/c.s/c. protection with Spreaders Terminal, Phase Barriers, Extended Rotary Operating Handle - 1 Set\nPhase Indicating Lamps, Red,Yelow Led Type- 2 No.\nPhase Indicating Lamps, Blue Led Type - 1 No.\nControl MCB, 6A, SP, 10KA - 4 No.\nNeutral Link, 20A - 1 No.\nVIF METER - 1 No.\nIndicating Lamps, On.Off.Trip Led Type - 3 No.\nCT,s 200/5A, class 1, 15VA, Tapewound - 4 No.\nCT Shorting Links - 4 No. BI01010001010000000000000515BI0100001390
279 164.6 Outgoing Feeders\n100 A, MCCB, 4 Pole, 50KA with Thermal Megnatic Release, o/c.s/c. protection with Spreaders Terminal, Phase Barriers, Extended Rotary Operating Handle - 2 Set\nIndicating Lamps, On.Off. Trip Led Type - 6Nos.\nControl MCB, 6A, SP, 10KA - 2 No.\nTrip Alarm Contact - 2 No.\n4 POLE MCB 63 AMP, C CURVE, 10 KA - 14 NOS. BI01010001010000000000000515BI0100001391
280 165 Supply and fixing of Rubber insulation matt 2mtrx1mtrx12mm of approved make to prevent electric shock as reqd complete in all respects including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001392 4 each
281 166 Supply, installation, testing & commissioning of Recess Mounting powder coated white 45 Watt LED Panel 2 feet x 2 feet (LED BACKLIT PANEL: CYGNUS-C SERIES) Light of C&S Make - Model No. CYGNUS-C/45W/2X2/W or other Equivalent Make Philips and Havells with all accessories with including to making connections, testing etc. as required including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001393 23 each
282 167 Supply, installation, testing & commissioning of Surface Mounting powder coated white 45 Watt LED Panel 2 feet x 2 feet (LED SURFACE MOUNTED BACKLIT PANEL: CYGNUS-CS SERIES) Light of C&S Make - Model No. CYGNUS-CS /45W/2X2/W or other Equivalent Make Philips and Havells all accessories with including to making connections, testing etc. as required including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001394 40 each
283 168 Supply, installation, testing & commissioning of Recess Mounting, Round 12 Watt LED Light of C&S Make - Model No. CARINA-RND/12W/W or other Equivalent Make such as Philips and Havells all accessories with including making connections, testing etc. as required including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001395 43 each
284 169 Supply, installation, testing & commissioning of Recess Mounting, Square 20 Watt LED Light of C&S Make - Model No. CARINA-SQ/20W/W or other Equivalent Make such as Philips and Havells with all accessories including making connections, testing etc. as required including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001396 55 each
285 170 Supply, installation, testing & commissioning of Surface Mounting, Round 12 Watt LED of C&S Make - Model No. CORONA-RND/12W/W or other Equivalent Make such as Philips and Havells with all accessories including making connections, testing etc. as required including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001397 28 each
286 171 Supply, installation, testing & commissioning of Surface Mounting, Square 18 Watt LED Light of C&S Make - Model No. CORONA-SQ/18W/W or other Equivalent Make such as Philips and Havells with all accessories including making connections, testing etc. as required including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001398 28 each
287 172 Supply, installation, testing & commissioning of Surface Mounting, 10 Watt LED Light 2 feet of C&S Make - Model No. NAKSHATRA/10W/W or other Equivalent Make such as Philips and Havells with all accessories including making connections, testing etc. as required including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001399 18 each
288 173 Supply, installation, testing & commissioning of Surface Mounting, 20 Watt LED, 4 Feet T-5 Light of C&S Make - Model No. NAKSHATRA/20W/W or other Equivalent Make such as Philips and Havells with all accessories including making connections, testing etc. as required including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001400 52 each
289 174 Supply, installation, testing & commissioning of 30 Watt LED, Flood light of C&S Make - Model No. ORION-C/30W/W or other Equivalent Make such as Philips and Havells with all accessories including making connections, testing etc. as required including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001401 1 each
290 175 Supply, installation, testing & commissioning of 12 Watt LED, Bulk Head Light of C&S Make - Model No.SIRIUS/12W or other Equivalent Make such as Philips and Havells with all accessories including making connections, testing etc. as required including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001402 15 each
291 176 Supply, installation, testing & commissioning of 400 Watt LED, Flood light (Street Light) of C&S Make - Model No. ORION-H/400W/W or other Equivalent Make such as Philips/Havells with all accessories with including to making connections, testing etc. as required including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001403 21 each
292 177 Supplying /installation & Fixing of 625 kVA DG Set of Sudhir Make & other Equivalent Make approved by the Engineer Incharge with 3 years AMC from the date of commissioning including carriage of materials in all lead & lif i.e. through manual & mechanical means and loading/unloading etc. complete. BI01010001010000000000000515BI0100001404 1 each
293 177.1 Supply, Installation, Testing and Commissioning of Diesel Engine driven generating set conforming to IS - 4742, of approved make Remote Manual Start type, 415 volts, 3 phase, 4 wire, AC system with relay panels for automatic starting on mains failure, control panel and of capacity 625 KVA/500kW complete with all accessories, fuel tank, fuel pump, day tank including cost of over ground under ground cabling of required size/dia of approved make for engine and including foundations and anti viberation mounting as required and as directed. 500 KW / 625 KVA Diesel Generating Set, Incorporating: Diesel Engine, water cooled Turbo charged along with following accessories. - 1 No.\nCOUPLED TO: Alternator rated at 500 KW / 625 KVA, 415 V, 3 Phase, 50 c/s, P.F. 0.8 BI01010001010000000000000515BI0100001405
294 177.2 MOUNTED ON: A channel iron base frame\nManual Control panel with Provision :-\nStarting of DG Set from remote AMF panel comprising of 1No - 1000Amps 4P , MCCB with MP Release , O/C , E/F & Shunt trip of fault breaking capacity 50kA (ICS = ICU) Manually operated with rotary Handle and other standard accessories with multifunction meter to indicate volts , Amps KW, MDI , KWH HZ, R,Y,B ON/OFF ; LED indicating lamps with hooter for failure trip warning . Make :- L&T / Schneider / Siemens\nBatteries : 2 Nos. 12V, 150AH with leads and terminals with batteries charging system . Engine instrument control Panel to Monitor all engine parameters and control of manual / auto / warniong devices to indicate / trip the engine in case of high water temp., Low Engine oil, high speed etc RPM Indicator and Engine Running HR. Meter. BI01010001010000000000000515BI0100001406
295 177.3 Outdoor Acoustic Enclosure suitable for 625 KVA DG set Base Frame, manufactured of CRCA sheet 1.6mm thick and shape having proper rigid supports of the set suitable for dismantling and re assembly at site, with openable air tight doors with suitable Gasket and spring locking arrangement. The interior fixed with mineral rock fibre slabs confirming to IS standard having 96 kg/m3 density for the insulation. The material shall be fire resistant low moisture absorption and low thermal conductivity of 75mm thickness. All insulated area shall be covered with perforated hot dip CRCA sheet 1.6mm thick above the mineral rock fibre padding. The silencer shall be three chamber design and logged with asbestos rope or glass wool. The Acoustic enclosure complete shall be able to achieve noise limit of 75 dBA at 1 mtr and also fulfill all statutory norms & regulations of the local Authorities for the DG set installation. BI01010001010000000000000515BI0100001407
296 177.4 Providing and Fixing , BusBar box with BusBar Links on DG Sets Alternator / LV Breaker to Connect LT Cable 3.5C x 400 sqmm Alu. Conductor Armoured - 1 Set.\nApproval of orientation drawings of DG sets from Chief Electrical Inspector/HPSE Ltd. (No extra cost will be paid). BI01010001010000000000000515BI0100001408
297 178 Providing and fixing following type of surface mounting decorative Bajaj make LED BOLLARDS TETRIS CAT NO. BGBOS600 9W LED RECTANGULAR IN SHAPE VICTORIAN DESIGN WITH OPAL ACRYLIC DIFFUSER AND IP65 PROTECTION1 including civil work, complete with all accessories, connections, testing and commissioning etc. as required including carriage of materials through manual& mechanical means including loading/unloading etc. complete in all lead & lift and direction of the Engineer Incharge. (Philips/Bajaj/Wipro make) BI01010001010000000000000515BI0100001409 15 Each
298 179 Providing and fixing following type of surface mounting decorative Bajaj make led light fixture Cat no.-112492 15W/M led strip including driver complete with all accessories, connections, testing and commissioning etc. as required.(Philips/Bajaj/Wipro make or as approved by site engineer) BI01010001010000000000000515BI0100001410 100 Mtr.
299 180 Supply Installation Testing and commissioning of smart integrated solar streetlight Bajaj make(sunsoko) 12w without hybrid switch 3 days backup,20wp panel capacity and 9AH built in mono crystline panel lithium ion Battery (LiFeP04) . The system constituents with integrated MPPT charge controller and PIR sensor with colour temp. 6000-6500k . The pole should be 4 Meter long having nominal bore dia. 65 mm planting depth 80 cm with pit depth 95 cm. Galvanized Iron (G.I.) pipe pole 'A' quality of and dia. 4.47 mm thickness, including fixing up to a given depth below G/L.The hole of excavation about 30 cm dia. and given depth to be filled in up to 15 cm below G/L with 1:3:6 cement concrete and there above plinth with 1:2:4 cement concrete up to a height of 45 cm from G/L.complete in all respects including carriage of materials in all lead & lift through manual & mechanical means and direction of the Engineer Incharge. . (Philips, Bajaj or equivelent as approved by Engineer -in-charge. BI01010001010000000000000515BI0100001411 10 Each
300 181 Supply and erection of Ceiling lamp brown brush suitable for 8X7 w LED lamp Philips make Cat No: 36998 brown brush with all accessories including cost of 8 Nos.7W LED lamps and connection as required or its equivalent as approved by engineer in charge including carriage of materials in all lead & lift. BI01010001010000000000000515BI0100001412 2 Each
301 182 Supplying , Installation of 300x50x2mm G.I. Perforated cable tray with suspended material, Coupler, etc of approved make including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001413 40 Mtr
302 183 Supplying and fixing Moduler Base And Cover Plate, 6 Modules of approved make including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001414 65 each
303 184 Supplying, installing, testing and commissioning of lifts (ThyssenKrupp/OTIS/Schindler/Johnson ) of following specifications. \nProtected by Center Opening Sliding Steel Doors in Powder Coated Finish.\nDRIVE SYSTEM ACVF.Clear Opening about 800 mm wide x 2000 mm high.\nCar walls finish in stainless steel hairline,Car walls finish in stainless steel hairline, Automatic evacution to nearest floor(ARD).Granite flooring finish in black sea,Deco ceiling finish in stainless steel hairline,Full height mirror on rear car panel,Stylish touch sensitive glass panel,Door open/close alarm button,Visual and acoustic confirmation of call,Car Position Indicator,Pre-annoucing arrows for collective controls,16 Segment display, Fully automatic landing doors in stainless steel hairline finish, landing door unit integrated on Top floor door frame,closed loop control system, Protection against power fluctuation,self diagnostic control, 2 hours fire rated landing doors,Overload Warning Indicator,light curtain on car entrance,alarm horn ,Attendant service via key switch, Auto fan off,Auto light off,Intercom-3 way voice sythesizer on car, out of service function,Fireman control panel etc. complette as per the direction of Engineer Incharge including loading/unloading, manual & mechanical transportation in all lead & lift upto site with 3 years AMC maintenance from the date of commissioning of lift. \n\n BI01010001010000000000000515BI0100001415
304 184.1 8 (Eight)Persons Capcity (544 kg.),Lift well size 2100mmx2100mm AND 1800MMX1800 MM ,,Clear opening of door ,Travel (Ground,Ist &IInd Floor) , Three Stops (Ground,Ist &IInd Floor), levels,all openings on same side,Door opening W-800mmxH-2000mm.Stainless steel (Schindler 5300 IN no. 00100), Gearless and Machineroom less BI01010001010000000000000515BI0100001416 1 Each
305 185 Providing and laying 'C' class MS. pipes (conforming to IS:1239 PART-I) for wet riser with butt welding type fittings with necessary joints to stand designed working pressure complete with flanges and fittings with heavy support brackets both including two coats of enamel paint over a coat of primer of approved qualilty and shade including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001417
306 185.1 150 mm.dia.(Hydrant Wet Riser) for bloch E & B BI01010001010000000000000515BI0100001418 20 Mtrs
307 185.2 100 mm.dia. BI01010001010000000000000515BI0100001419 3 Mtrs
308 186 Supplying and fixing 65 mm dia Single outlet type hydrant landing valve in SS with C.I. Hand wheel & tested to 21 kg/cm2 pressure conforming to IS-5290 ) with companion flanges nuts bolts, washers, gasket, PVC cap & chain etc. complete as specified of approved make including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001420 3 Each
309 187 Supplying and fixing swinging type wall mounted fire hose reel to IS 12585 with fire hose of braided rubber to IS 444 suitably reinforeced 19 mm size and 30 Mtrs. Length with 10 mm tapering branch nozzle in Brass male and female coupling with cut off valve of 25Ø attachment including fixing with approved anchor fastners and bolts, complete as specified of approved make including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001421 3 Each
310 188 Supplying and fixing 2 lengths of 63 mm dia canvas hose with each 15 m long as per IS:8423, 2 nos instantantaneous SS Coupling duly bound to the each hose as per IS:903 of approved make including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001422 13 Sets
311 189 Supplying and fixing SS branch pipe with nozzle as per IS 903 of approved make including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001423 13 Sets
312 190 Providing and fixing in position 16 guage MS hose box of size (750x600x250 mm. Double Shutter) for canvas hose with locking arrangement complete including applying 2 coats of enamel paint of approved shade (post office red) over a coat of primer complete as per the site requirement including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001424 13 Each
313 191 Providing and fixing Suitable C.I. air release valve of 25mm.dia. With Necessary Cutoff with Painting for Wet riser trermination.(Hydrant Wet Riser ) of approved make including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001425 2 Each
314 192 Providing and fixing C.I.double flanged wafer type butterfly Valve of approved make and and tested to 15 kg/sq cm CI body and working parts companion flanges and rubber gasket packing, bolts, nuts, washers, etc complete of approved make including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001426
315 192.1 150 mm dia (For Hydrant & Sprinkler Wet Riser) BI01010001010000000000000515BI0100001427 2 Each
316 193 Providing and fixing 'C' class MS.pipes Confirming to IS1239 & 3589 in to walls, ceilings, floors etc. with screwed sockets, back nuts, plugs, clamps, etc. including necessary drilling holes in walls/slabs etc, and anticorrisive primer and two coats of oil painting etc. complete including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001428
317 193.1 25 mm dia BI01010001010000000000000515BI0100001429 110 Mtrs
318 193.2 32 mm dia BI01010001010000000000000515BI0100001430 4 Mtrs
319 193.3 40 mm dia BI01010001010000000000000515BI0100001431 4 Mtrs
320 193.4 50 mm dia BI01010001010000000000000515BI0100001432 6 Mtrs
321 193.5 65 mm dia BI01010001010000000000000515BI0100001433 12 Mtrs
322 194 Supply and installation of Pendent Sprinkler head with the following temperature rating & respond, universal deflector, chromium finish as per specifications.Size:15-mm dia of approved make including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001434
323 194.1 Temperature Rating: 68°C (K=80) Standard response BI01010001010000000000000515BI0100001435 34 Each
324 195 Supply and installation of Butterfly / Ball Valve of approved make including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001436
325 195.1 65 Dia BI01010001010000000000000515BI0100001437 2 Each
326 196 Providing and fixing 'C' class MS.pipes Confirming to IS1239 & 3589 of approved make in to walls, ceilings, floors etc. with screwed sockets, back nuts, plugs, clamps, etc. including necessary drilling holes in walls/slabs etc, and anticorrisive primer and two coats of oil painting etc. complete including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001438
327 196.1 150Ø ( Hydrant ) BI01010001010000000000000515BI0100001439 230 Mtr
328 196.2 80Ø BI01010001010000000000000515BI0100001440 30 Mtr
329 197 Providing and fixing, wrapping coating on 150 mm dia pipe etc. complete in all respect including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001441 50 Mtr
330 198 Providing and fixing Fire Brigade Collective Breaching with 4 Nos. 63 mm dia SS Instantaneous Coupling of approved make including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001442 1 Each
331 199 Providing and fixing Fire Service Inlet connection fabricated from MS. pipe with 4 nos. 63 mm. dia. SS male hydrant connection for the wet riser complete including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001443 1 SET
332 200.1 Providing and fixing CI Wafer Type Butterfly valve 150 mm dia for FSI of approved make including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001444 1 Each
333 200.2 Providing and fixing CI Wafer Type Dual Plate Non Return valve 150 mm dia for FSI including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001445 1 Each
334 201 Providing and fixing SS single headed hydrant valve as per IS-5290 with 80 mm dia x 2 mts m.s. stand post as a courtyard hydrant including painting underground protection, complete with including rubber gasket, nuts, bolts, washers etc. of approved make including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001446 10 Each
335 202 Supply, erection, testing & commissioning of electrical motor of approved make single stage, single outlet driven main pump of horizontal centrifugal end suction back pull out type with gland packing and capable to deliver 2280 LPM at 70m head with CI casing ,Bronze impeller & SS 304 Shaft . The pump shall be directly coupled to TEFC motor of suitable HP (3 phase connection,440V) with suitable RPM and complete set shall mounted on common base frame. The quoted rate shall include providing & fixing of coupling guard and Foundation bolts etc complete with 3 years AMC from the date of commissioning. (Hydrant Pump) including manual & mechanical carriage and loading/unloading etc. upto working site and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001447 1 Each
336 203 Supply, erection, testing & commissioning of Diesel Engine Driven, single stage, single outlet main pump of horizontal centrifugal end suction back pull out type with gland packing and capable to deliver 2280 LPM at 70 m head with CI casing ,Bronze impeller & SS 304 Shaft of approved make . The pump shall be directly coupled to TEFC motor of suitable HP (3 phase connection,440V) with suitable RPM and complete set shall mounted on common base frame. The quoted rate shall include providing & fixing of coupling guard and Foundation bolts etc complete with 3 years AMC from the date of commissioning of DG Set.(Standby Pump) including manual & mechanical carriage and loading/unloading etc. upto working site and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001448 1 Each
337 204 Supply, erection, testing & commissioning of electrical motor, single stage, single outlet driven main pump of horizontal centrifugal end suction back pull out type with gland packing and capable to deliver 180 LPM at 70m head with CI casing ,Bronze impeller & SS 304 Shaft of approved make . The pump shall be directly coupled to TEFC motor of suitable HP (3 phase connection,440V) with suitable RPM and complete set shall mounted on common base frame. The quoted rate shall include providing & fixing of coupling guard and Foundation bolts etc complete with 3 years AMC from the date of commissioning. (Jockey Pump) including manual & mechanical carriage and loading/unloading etc. upto working site and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001449 1 Each
338 205 Providing and fixing automatic motor control centre of approved make for hydrant main,, Stand By Diesel Engine Pump jockey pump suit the HP of motor for the rated capacity and desired head of pumps. MCC shall be provided with suitable starters and controls for comprising of automatic switch unit isolators, pressure switches to set operating pressure, switches rated 500 Volt AC 50 Hz supply for continuous maximum load and Supply Company's regulations, contacts of suitable size, internal isolating baffles, terminal boxes for cables suitably screwed, standard 250 volts 15 Watt bayonet cap, indicator lamps for the respective pumps behind ruby domes suitably protected against damage, interlocking arrangements as per Fire Brigade stipulations, auxilary switch / switches to provide warning by lighting of a lamp and hooters for audible alarm both at pump room and main fire console, tripping a circuit breaker connecting the electric supply to leave ample power for Fire Pump, if so required Auxilary switch to be rated at 5 Amps. 250 Volts AC complete with C.T connected ammeters, volt meters and selector are to be provided on the panels for each starter and incoming switch fuse unit including necessary power & control cabling from panel to respective pumps complete as specified etc. complete with 3 years AMC from the date of commissioning in all respect including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001450 1 SET
339 206 1100 V grade, ISI mark PVC insulated and PVC sheathed cable of approved make including carriage of materials in all lead & lift and direction of the Engineer Incharge. \nNOTE: Incoming cable connection from the meter room to the control panel in the pump house is in the scope of the client BI01010001010000000000000515BI0100001451
340 206.1 3 C x 70 sq mm aluminum arm. BI01010001010000000000000515BI0100001452 40 Mtr
341 206.2 3 C x 4 sq mm copper arm. BI01010001010000000000000515BI0100001453 20 Mtr
342 206.3 2 C x 1.5 sq mm copper flx. BI01010001010000000000000515BI0100001454 80 Mtr
343 206.4 10 C x 1.5 sq mm copper flx. Cable BI01010001010000000000000515BI0100001455 20 Mtr
344 207 Providing and fixing 'C' class M.S.pipes Confirming to IS1239 & 3589 of approved make in Pump Rooms to walls, ceilings, floors etc. with screwed sockets, back nuts, plugs, clamps, etc. including necessary drilling holes in walls/slabs etc, and anticorrisive primer and two coats of oil painting etc. including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001456
345 207.1 150 mm dia BI01010001010000000000000515BI0100001457 18 Mtrs
346 207.2 100 mm dia BI01010001010000000000000515BI0100001458 8 Mtrs
347 207.3 80 mm dia BI01010001010000000000000515BI0100001459 15 Mtrs
348 207.4 50 mm dia BI01010001010000000000000515BI0100001460 8 Mtrs
349 207.5 25 mm dia BI01010001010000000000000515BI0100001461 25 Mtrs
350 208 Providing and fixing of CI double flanged Wafer Type butterfly Valve of approved make and and tested to 15 kg/sq cm CI body and working parts companion flanges and rubber gasket packing, bolts, nuts, washers, etc (PN 20) including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001462
351 208.1 150 mm dia BI01010001010000000000000515BI0100001463 4 Each
352 208.2 80 mm dia BI01010001010000000000000515BI0100001464 2 Each
353 208.3 50 mm dia butterfly valve BI01010001010000000000000515BI0100001465 1 Each
354 208.4 25 mm dia ball valve BI01010001010000000000000515BI0100001466 6 Each
355 209 Providing and fixing of C.I.Double flanged approved make wafer type Dual Plate check valve standard approved make water works pattern conforming to IS 778 and tested to 15 kg/sq cm C I body and working parts companion flanges and rubber gasket packing, bolts, etc (PN 20) including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001467
356 209.1 150 mm dia BI01010001010000000000000515BI0100001468 2 Each
357 209.2 80 mm dia BI01010001010000000000000515BI0100001469 1 Each
358 209.3 50 mm dia BI01010001010000000000000515BI0100001470 1 Each
359 210 Supplying and fixing wrought steel or MS fabricated air vessel in pump room 200 mm dia and 1200 mm high on M.S. stand with necessary arrangement of approved make and including drain pipes to the channel in Pump Room including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001471 1 Set
360 211 Providing and fixing of pressure switch of approved make including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001472
361 211.1 25 mm dia BI01010001010000000000000515BI0100001473 3 Each
362 212 Providing and fixing of Pressure guage with siphon and cock complete including carriage of materials in all lead & lift and direction of the Engineer Incharge. \n(Sintex or Equivalent) BI01010001010000000000000515BI0100001474 4 Each
363 213 Providing and fixing of Priming Tank 1000 Ltrs of approved make including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001475 1 Each
364 214 Providing and fixing of Foot Valve BI01010001010000000000000515BI0100001476
365 214.1 150 mm dia BI01010001010000000000000515BI0100001477 2 Each
366 214.2 100 mm dia BI01010001010000000000000515BI0100001478 1 Each
367 215 Supply, installation , testing & commissioning of semi addressable 2 Zone Fire Alarm Panel with battery back up, charger, network Card etc. complete with selector switches for alert/evacuate of approved make including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001479 1 Each
368 216 Supply, installation, testing & commissioning recessed type semi addressable Manual Call Point with hooter including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001480 3 Each
369 217 Supply, installation, testing and commissioning analog addressable Photo Electric type smoke detectors ceiling mounted including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001481 18 Each
370 218 Supply, installation, testing and commissioning of analog addressable fixed temperature and rate of rise type heat detectors including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001482 1 Each
371 219 Supply, installation, testing & commissioning of following 1.5 sq.mm. Copper armoured PVC insulated cable, for wiring between alarm station, hooter detector, panels, complete with interconnection and termination etc. including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001483
372 219.1 2 C x 1.5 Sq.mm BI01010001010000000000000515BI0100001484 300 mtrs.
373 219.2 6 C x 1.5 Sq.mm BI01010001010000000000000515BI0100001485 25 mtrs.
374 220 ABC Type Fire Extinguisher BI01010001010000000000000515BI0100001486
375 220.1 6 Kg Capacity of approved make including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001487 12 Each
376 221 CO2 Type Fire Extinguisher BI01010001010000000000000515BI0100001488
377 221.1 4 Kg Capacity BI01010001010000000000000515BI0100001489 3 Each
378 222 Providing and fixing fire bucket stand with four no. fire buckets complete in all respect, or as per norms of fire dept. BI01010001010000000000000515BI0100001490
379 222.1 Fire stand with buckets of approved make including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001491 2 Each
380 223 Providing and fixing standard fireman's axe with heavy rubber handle of approved make including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001492 20 Each
381 224 Providing and Fixing of IP Network Dome HD4 megapixel IR IP camera adopts 1/2.5" Progressive Scan CMOS;H.265+/H.265/H.264+/H.264/MJPEG; Ultra low light, Color: 0.008 lux @(F1.2, AGC ON), 0 lux with IR, Color: 0.014 lux @(F1.6, AGC ON), 0 lux with IR 2688 × 1520@30 fps 5VCA functions; 3 streams; 120dB Wide Dynamic Range 3D DNR; BLC; ICR; EXIR; IR range: up to 40 m IP67, IK10 DC12V&PoE; Built-in micro SD/SDHC/SDXC slot upto 128GB. Certification FCC, CE and ISO 9001: 2008, UL, IK10, IP67.MAKE: Pelco,Hikvision, Mobotix, Axis.as per direction of of Engineer-Incharge including carriage of material in all lead and lifts BI01010001010000000000000515BI0100001493 34 Each
382 225 Providing and Fixing of IP Network Bullet HD 4 megapixel IR IP camera shall adopts 1/2.8" Progressive Scan CMOS H .265+/H.265/H.264+/H.264/ MJPEG; Color: 0.005 Lux @ (F1.2, AGC ON), 0 Lux with IR, Color: 0.009 Lux @ (F1.6, AGC ON), 0 Lux with IR 1920 × 1080 @60fps 5VCA functions; 3 streams; 120dB Wide Dynamic Range 3D DNR; BLC; ICR; EXIR; IR range: up to 90m IP67 DC12V&PoE; Built-in micro SD/SDHC/SDXC slot upto 128GB. Certification FCC, CE and ISO 9001: 2008, UL, IK10, IP67.MAKE: Pelco,Hikvision, Mobotix, Axis.as per direction of of Engineer-Incharge including carriage of material in all lead and lifts BI01010001010000000000000515BI0100001494 15 Each
383 226 Providing and Fixing of 16CH NVR 2 SATA Dual OS design to ensure high reliability of system running ANR technology to enhance the storage reliability when the network is disconnected H.265/ H.265 H.264/ H.264+ MPEG4 video formats Recording at up to 8 MP resolution HDMI and VGA independent outputs provided 1 self adaptive 10 M/100 M/1000 Mbps network interface Incoming bandwidth 160Mbps/ Outgoing bandwidth 160Mbps Up to 2 SATA interfaces connectable for recording and backup, 6TB per SATA.Should support standard network protocoles likes TCP/IP, DHCP, HIK Cloud P2P, DNS, DDNS, NTP, SADP, SMTP, NFS, iSCSI, UPnP™.4 Alarm input/ 1 alarm out.UL, CE, FCC, RoHS, BIS; MAKE: Pelco, Hikvision, Mobotix, Axis. as per direction of of Engineer-Incharge including carriage of material in all lead and lifts \n BI01010001010000000000000515BI0100001495 4 Each
384 227 Supply Installation Testing & Commissioning of 43" LED , Full HD,HDMI Port, Component Video Inputs,1 Digital Audio out including carriage of materials in all lead & lift and direction of the Engineer Incharge. Make : Sony/LG/Samsung. BI01010001010000000000000515BI0100001496 3 Each
385 228 Supply Installation Testing & Commissioning of 10TB HDDs Complete in all respect as directed by Engineer-in-Charge; Make: WD/Seagate.as per direction of of Engineer-Incharge including carriage of material in all lead and lifts BI01010001010000000000000515BI0100001497 4 Each
386 229 Supply Installation Testing & Commissioning of Client PC Intel 5th generation Core i7 or above, 8 MB, 5 X SATA Connector, Video Graphics Card NVIDIA Quadro P4000, with Original Window Pro 10 including carriage of materials in all lead & lift and direction of the Engineer Incharge. . Make :Dell/Acer/HP\n BI01010001010000000000000515BI0100001498 1 Each
387 230 Supply Installation Testing & Commissioning of Category 6 Unshielded Twisted Pair 23 AWG LSZH, 4 pair 100W cable shall be complaint with ANSI/TIA/EIA-568-C.2 Additional Transmission Performance Specifications for 4-pair 100W Category 6 Cabling. Tested upto 600 MHZ, Construction: 4 twisted pairs separated by internal X shaped, 4 channel, Polymer spine/full separator. Half shall not be accepted including carriage of materials in all lead & lift and direction of the Engineer Incharge. . Make R&M,Panduit, Dlink,Siemon. BI01010001010000000000000515BI0100001499 3500 Mtr
388 231 Supply Installation Testing & Commissioning of 24 Port Patch panel with straight frame. This should be mounted in closed racks. Allow for a minimum of 200 re-terminations without singal degradation below standards compliance limit. IDC: Suitable for 22-26 AWG stranded and solid wire compatible with both 110 & Krone punch down tools; Improved cable management with optional cable management bar; Each port/jack on the panel should be individually removable on field from the panel; Insertion Force: 20N max (IEC 60603-7-4) including carriage of materials in all lead & lift and direction of the Engineer Incharge. . Make R&M,Panduit, Dlink,Siemon. BI01010001010000000000000515BI0100001500 5 Each
389 232 Supply Installation Testing & Commissioning of 16 Port 10/100Mbps ports unmanaged switch that requires no configuration and provides 8 PoE (Power over Ethernet) ports. It can automatically detect and supply power with all IEEE 802.3af/at compliant Powered Devices (PDs). In this situation, the electrical power is transmitted along with data in one single cable allowing you to expand your network to where there are no power lines or outlets, where you wish to fix devices such as IP Cameras or IP Phones, etc. PoE power budget 240W. Plug-and-play installation. 4K MAC address entries. Network Port 9. PoE Port 8,10/100Mbps RJ 45 Port, per point coverage 250mtr minimum including carriage of materials in all lead & lift and direction of the Engineer Incharge. Make: Dlink, Cisco, Hikvision.as per direction of of Engineer-Incharge including carriage of material in all lead and lifts \n BI01010001010000000000000515BI0100001501 4 Each
390 233 Supply Installation Testing & Commissioning of L2 Managed enterprise 24 Port 10/100/1000Mbps ports managed switch that requires no configuration and provides 24PoE (Power over Ethernet) ports. It can automatically detect and supply power with all IEEE 802.3af/at compliant Powered Devices (PDs). In this situation, the electrical power is transmitted along with data in one single cable allowing you to expand your network to where there are no power lines or outlets, where you wish to fix devices such as IP Cameras or IP Phones, etc. PoE power budget 384W with 4 SFP dedicated port. Make: Juniper, Cisco, Netgear.as per direction of of Engineer-Incharge including carriage of material in all lead and lifts BI01010001010000000000000515BI0100001502 1 Each
391 234 Supply Installation Testing & Commissioning of CAT6 IO Complete. Make R&M,Panduit, Dlink,Siemon.as per direction of of Engineer-Incharge including carriage of material in all lead and lifts BI01010001010000000000000515BI0100001503 49 Each
392 235 Supply Installation Testing & Commissioning of CAT6 Patch Cords 3ft. Make R&M,Panduit, Dlink,Siemon.as per direction of of Engineer-Incharge including carriage of material in all lead and lifts BI01010001010000000000000515BI0100001504 49 Each
393 236 Supply Installation Testing & Commissioning of CAT6 Patch Cords 7ft. Make R&M,Panduit, Dlink,Siemon.as per direction of of Engineer-Incharge including carriage of material in all lead and lifts BI01010001010000000000000515BI0100001505 49 Each
394 237 Supply Installation Testing & Commissioning of Online 5 KVA UPS with Galvanic Isolation Transformer with 42AH Sealed maintenance free Batteries with 7560 VAH complete as required by Engineer-In-charge.UPS shall be suitable for at least 1 hour battery backup on full load. Make : Vertive (Emerson) /APC/Numeric as per direction of of Engineer-Incharge with 3 years AMC from the date of commissioning including carriage of material in all lead and lifts BI01010001010000000000000515BI0100001506 1 Each
395 238 Supply Installation Testing & Commissioning of 19" 9U IP55 standard Outdoor Rack with Lockable Steel Door, Rigid frame that can be fixed to the pole Front Door with Filter, Louver & T type Lock 90CFM, 230V AC Fan - 2 Nos, front door Self adhesive thermal foam from inside Door Hinges - 2 Nos Cable Glands at bottom side for cable entry 19" ; 2 Nos for equipment mounting Gasket ( As per IP55 Standard ) Pole Mounting Brackets at rear side- 2 Nos Hood For Air Inlet at front side Powder Coated Surface.Light Grey -RAL 7035-powder coated, Conforming to DIN 41494. Make :Rittal,D-Link,APW.as per direction of of Engineer-Incharge including carriage of material in all lead and lifts BI01010001010000000000000515BI0100001507 4 Each
396 239 Supply Installation Testing & Commissioning of 24U Enclosure Frame-600X800-STEEL fabricated out of CRCA steel, CNC programmed, punched, bended, welded and Powder coated with highest quality standards. With Front Glass Door,Hexagonal Perforated Door-24-600 with 3 Point Lock Swing Handle,Glass Door-600-24U,Adjustable Levelers set of 4,Casters Set of 4,FHU with 2 FAN 180CFM,Horizontal Power Distribution Unit with 6 x 5/15A sockets Round Pin, 230 Volts AC, 32 Amp with Plug,Earthing Kit,Horz. Cable Manager-1U-Loop, Conforming to DIN 41494 or equivalent standard. Make :Rittal,D-Link,APW.as per direction of of Engineer-Incharge including carriage of material in all lead and lifts BI01010001010000000000000515BI0100001508 1 Each
397 240 S/F PVC conduit: Supplying and fixing of following sizes of PVC conduit alongwith the accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. as per direction of of Engineer-Incharge including carriage of material in all lead and lifts BI01010001010000000000000515BI0100001509
398 240.1 32MM BI01010001010000000000000515BI0100001510 1200 Mtr
399 241 Providing, installation and commissioning Digital EPABX Matrix model ETERNITY GE 12 S   expandable 96 ext  56ext analog with 3 years AMC from the date of commissioning and as per direction of of Engineer-Incharge including carriage of material in all lead and lifts BI01010001010000000000000515BI0100001511 1 each
400 242 8 nos co port 01 op console beetal cli phone BI01010001010000000000000515BI0100001512 1 each
401 243 mdf with ipm BI01010001010000000000000515BI0100001513 6 each
402 244 U.P.S with battery with 4 hour back up BI01010001010000000000000515BI0100001514 1 each
403 245 Telephone instruments BI01010001010000000000000515BI0100001515 14 each
404 246 Locker Unit\nProviding & fixing Greenlam Sturdo Locker unit (of following standard dimension) made of heat, bacteria, water, chemical, scratch, impact anti bacterial resistant 9 mm and 3mm thick solid compact laminate panels tested by Shriram Test House. Finish of the compact laminate should be Suede / *Raw Silk, texture/shade as per the detail drawings & as per IS 2046 (Indian Standard) and as per fire retardant BS-476/97 standard. The product should have Green Guard Certificate.\nThis also includes providing and fixing in position necessary hardware made out of Stainless steel (Grade 304) as per manufacturer’s specifications & Architects/Engineer Incharge including carriage of materials in all lead & lift.\ninstructions like (1) Door Knob, (2) Hinges, \nAll screws will of 304 Grade in stainless steel with satin finish. \nDoors : 9mm \nCarcas : 3mm\nSize : 300mm (W) X 450mm (D) X 1800mm (H) Per unit) .. TOTAL Column Height - 1800mm A 3 Type \na) Stainless Steel-304 Cam Lock \nb) Stainless Steel-304 Hinges \nc) Aluminium U & F Channels \nd) Stainless Steel-304 Screws BI01010001010000000000000515BI0100001516 20 each
405 247 Toilet Cubical\nProviding & fixing Greenlam Sturdo Vibrance Serene Toilet Cubicle (of following standard dimension which includes 600mm door size width) made of heat, bacteria, water, chemical, scratch, impact and anti bacterial resistant 12mm thick solid compact laminate panels tested by Shriram Test House. Finish of the compact laminate should be Suede / *Raw Silk, which includs doors, pilasters & intermediate panels finished with approved texture/shade as per the detail drawings & as per IS 2046 (Indian Standard) and as per fire retardant BS-476/97 standard. The product should have Green Guard Certificate. \nThis also includes providing and fixing in position necessary hardware made out of Nylon Polyamide Grade-6 & Aluminium powder coated top rail as per manufacturer’s specifications & Architects instructions like (1) Door Knob, (2) Gravity Hinges, (3) Thumb turn lockset indicator, (4) Aluminum Top Rail, (5) Coat Hook, (6) U-Channels, (7) Adjustable Foot, (8) Noise Deafening Tape (9) Screws & wall plugs etc.\nThe top fitting should consist of Aluminium Powder Coated top rail which will get fixed with Mid & End pilasters. \nAll screws will of 304 Grade in stainless steel with satin finish. Top rail is extruded Aluminium will be powder coated or anodized (Grade 6063 Micron Aluminium). All pilasters are supported by grade- 6 Nylon Polyamide Thermoplastic palm design pedestal footing with non corrosive steel inserts. The base diameter 65mm and neck diameter of 33mm anchored to the floor with grade 304 satin finish stainless steel screws with push fit capping at a clearance height of 150mm. Model is Heat and Bacteria Resistant Polyamide in which aluminum U-Channel will be used for the fixing of intermediate panels to the wall including carriage of materials in all lead & lift and direction of the Engineer Incharge. BI01010001010000000000000515BI0100001517 8 each
406 248 Providing and fixing 6mm thick Suede Finish Greenlam, Trepsa,Mikasa exterior grade Clad(High Pressure Laminates) made up of 1300mm x 3050mm in size and manufactured under EN438-2&3:2005 standard . Clad should be resistance to water immersion characterstic with permissible increase on thickness and mass <0.60% and have density >1.35kg/M3, UV resistance on Grey scale measurement should be measured = 4, with flame retardant fulfilled the criteria of under EN13501-1:2007 with classification of BS1D0 standard property, Moisture resistant, Impact resistant, termite resistant, Scratch resistant, Weather and climatic shock resistant high pressure thermosetting resign treated balanced compact laminates Clad. (The manufacturer should provide 10 years warranty certification on manufacturing and moisture related defects). The Clad laminates fulfilled the criteria of FSC, and Green Guard Gold certification and should be with Anti bacterial property( under JIS Z2801:2000 standard). Clad should be installed on 14 gauge of Aluminium tubular tube in the size of 50mmx25mm or as pr site requirement at 400 mmc/c distance with the help of 5mm dia colour matched rivets as per manufacturer specification.These aluminum tubular tube should be fixed on wall with the help of 85x50x5mm thick dead load bracket and wind load bracket through 10mm fastener..Wind load bracket will have vertical slot & dead load bracket will have in horizontal slot. Maintain 6mm both horizontal and vertical gap between two installed clad panels. Shade designed of clad should be finalized under direction of Engineer –in-charge including carriage of materials in all lead & lift. BI01010001010000000000000515BI0100001518 75.06 sqm