Repair/Maintenance Of Voltage Stabilizers , U/G Cables , Lt Panels , Feeder Pillar Boxes , Control Switch Gear/Mccb , Earthing , Lt Distribution System , Split/Window Type Acs , Summer/Cooling Appliances And Connected Items At Af Stn Naraina Unde, GE (AF) Gurgaon-Haryana

Military Engineer Services-MES has published Repair/Maintenance Of Voltage Stabilizers , U/G Cables , Lt Panels , Feeder Pillar Boxes , Control Switch Gear/Mccb , Earthing , Lt Distribution System , Split/Window Type Acs , Summer/Cooling Appliances And Connected Items At Af Stn Naraina Unde. Submission Date for this Tender is 17-08-2019. Air Conditioner Tenders in GE (AF) Gurgaon Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

21187009
Repair/Maintenance Of Voltage Stabilizers , U/G Cables , Lt Panels , Feeder Pillar Boxes , Control Switch Gear/Mccb , Earthing , Lt Distribution System , Split/Window Type Acs , Summer/Cooling Appliances And Connected Items At Af Stn Naraina Unde
Open Tender
Indian
Haryana
GE (AF) Gurgaon
17-08-2019

Tender Details

repair / maintenance of voltage stabilizers , u / g cables , lt panels , feeder pillar boxes , control switch gear / mccb , earthing , lt distribution system , split / window type acs , summer / cooling appliances and connected items at af stn naraina under age e / m ( af ) ra

Key Value

Document Fees
INR 500 /-
EMD
INR 98000.0 /-
Tender Value
INR 49 Lakhs /-

BOQ Items

Sl. No. Item Description Item Code / Make Quantity Units
1 1 Supply, install, commissioning and testing factory made feeder pillar compartmentalised outdoor type ,weather proof ,dust and vermin proof double door front and rear openable made out of 3.15 mm thick CRCA sheet and angle iron 45x45x 6mm duly powder caoted ,suitable for floor /platform mounting of CPRI certified and IP65 class suitable for 415 volt ,3 phase ,4 wire ,50 hz AC supply sustem having busbar chamber with insulated aluminum busbars of rating 1200 amps installed on porcelain /SMC insulator with apron for cable entry ,closing locking arrangement with and including internal wiring with PVC insulated solid ,copper conductor FRLS cable ,IS 694 marked ,1100 volt grade of appropriate size (but not less than 2.5 sqmm ) and comprising of the following :- 1 Each\nJob
2 1.01 CABLE TERMINATION :-\nCable entries and terminals shall be provided in the Main/Sub distribution board to suit the number; type and size of aluminum conductor power cables and copper conductor control cable specified. Provision shall be made for top or bottom entry of cables as required. Generous size of cabling chambers shall be provided, with the position of cable gland and terminals such that cables can be easily and safely terminated. Barriers or shrouds shall be provided to permit safe working as the terminals of one circuit without accidentally touching that of another live circuit. Cable risers shall be adequately supported to withstand the effects of rates short circuit currents without damage and without causing secondary faults \nIncoming :-\n(a) 4 Pole ACB 800 Amps ,415 Volts -01 No \n(b) Digital Voltmeter -01 No. \n(c)Digital ammeter -01 No \n(e) Indicating lamps -01 Set of three\n
3 1.02 Outgoing :-\n(a) MCCB 3 pole ,315 Amp ,50 Hz ,415 volts ,50 KA with magnetic and thermal release -1 No \n(b) MCCB 3 pole ,250 Amp ,50 Hz ,415 volts ,35 KA with magnetic and thermal release -2 Nos\n(b) MCCB 3 pole ,160 Amp ,50 Hz ,415 volts ,25 KA with magnetic and thermal release -2 Nos \n(b) MCCB 3 pole ,100 Amp ,50 Hz ,415 volts ,25 KA with magnetic and thermal release -2 Nos \n(b) Provision for Spare MCCB -2 Nos \nPlatform of panel:- Platform for the panel with PCC 1:4:8 type D-2 using 40 mm graded crushed stone ,15 cm thick in foundation ,brick work in CM 1:6 with sub class B old size bricks ,rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6 type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be at a height of 45 cm above the nearest road level. The platform shall be constructed as per Manufacturer drawing and design.\n
4 2 Supply, install, commissioning and testing in replacement factory made feeder pillar compartmentalised outdoor type ,weather proof ,dust and vermin proof double door front and rear openable made out of 3.15 mm thick CRCA sheet and angle iron 45x45x 6mm duly powder caoted ,suitable for floor /platform mounting of CPRI certified and IP65 class suitable for 415 volt ,3 phase ,4 wire ,50 hz AC supply sustem having busbar chamber with insulated aluminum busbars of rating 600 amps installed on porcelain /SMC insulator with apron for cable entry ,closing locking arrangement with and including internal wiring with PVC insulated solid ,copper conductor FRLS cable ,IS 694 marked ,1100 volt grade of appropriate size (but not less than 2.5 sqmm ) and comprising of the following :- 1 Each\nJob
5 2.01 Incoming :-\n(a) MCCB 4 pole ,400 amp ,50 hz ,415 Volts ,50 KA with magnetic and thermal release -01 No \n(b) Digital Voltmeter 0-500 volts digital type with 4 way rotary selector switch -01 \n(c) Digital ammeter 0-400 Amp digital type with 4 way rotary switch -01 No \n(d) CTs ratio 400/5 A ,class 1 , ISI marked -01 set of three\n(e) Indicating lamps -01 Set of three\nOutgoing :-\n(a) MCCB 3 pole ,200 Amp ,50 Hz ,415 volts ,25 kA with magnetic and thermal release -4 Nos \n(b) MCCB 3 pole ,63 Amp ,50 Hz ,415 volts ,25 kA with magnetic and thermal release -4 Nos \n(b) Timmer Switch ,40 Amp , -1 No \nPlatform of panel:- Platform for the panel with PCC (1:4:8) type D-2 using 40 mm graded crushed stone aggregate) ,15 cm thick in foundation ,brick work in CM 1:6 with sub class B old size bricks ,rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6 type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be at a height of 45 cm above the nearest road level. The platform shall be constructed as per Manufacturer drawing and design\n\n
6 3 Supply, install, testing, commissioning and testing in replacement factory made feeder pillar compartmentalised outdoor type ,weather proof ,dust and vermin proof double door front and rear openable made out of 3.15 mm thick CRCA sheet and angle iron 45x45x 6mm duly powder caoted ,suitable for floor /platform mounting of CPRI certified and IP65 class suitable for 415 volt ,3 phase ,4 wire ,50 hz AC supply sustem having busbar chamber with insulated aluminum busbars of rating 400 amps installed on porcelain /SMC insulator with apron for cable entry ,closing locking arrangement with and including internal wiring with PVC insulated solid ,copper conductor FRLS cable ,IS 694 marked ,1100 volt grade of appropriate size (but not less than 2.5 sqmm ) and comprising of the following :- 3 Each Job
7 3.01 (a) MCCB 4 pole 250 Amps 35 KA-01 No (For incoming). \n(b) MCCB 3 pole 100 Amps 25 KA-02 Nos (For Outgoing).\n(c) MCCB 3 pole 63 Amps 25 KA-02 Nos (For Outgoing).\n(d) MCB TPN 40 Amps 10 KA-02 Nos (For Outgoing).\n(e) MCB SPN 16A 10KA-2 Nos \n(j) Automatic timer switch current rating 40 Amp 4 pole 415 volt -01 No\n(f) Digital multi function meter (Volt meter 0-500V,Ammeter 0-300A, frequency meter & power factor meter) of size 96mmx96mm with programmable CT ratio with back up protection by 2 A MCB SP.\n(g) Indicating lamp 240 volts LED type - set of three\n(h) Internal All links & control cable and inspection lamp -01\n(j) CTs 400 / 5 Amps - set of three\n
8 4 M&L for Dehydration including filteration and cleaning of Voltage stablizer oil by dehydrating machine incl testing of sample before and after dehydration and filteration all as specified and directed . \nNOTE:- Contractor has to arrange the dehydration machine and testing kit without any extra cost to the deptt. Test report to be submitted after completion of job. 2100 Litre
9 5 Supply & Filling /pouring of voltage stablizer oil of low viscosity having dielectric strength not less than 60 KV complete all as specified and as directed. \nNOTE:- Dielectric strength test shall be carried out at site before poring/filling in transformers in the presence of Engr-in-Charge on the site. 409 Litre
10 6 Disconnecting the deffective stablizer of Capacity upto 250 KVA from incoming and outgoing cables and opening the stablizers for checking the defects, draining out transformer oil and carrying to workshop for repair and back to site including making connections and testing complete including replacement of gasket set unserviceable nuts & bolts, washer complete all as specified and directed by the Engr in Charge. 2 Each Job
11 7 Supply and fix in replacement of micro switch complete all as specified and as directed. 2 Each
12 8 Supply and fix in replacement DPDT switches complete all as specified and as directed. 2 Each
13 9 Supply and fix in replacement Auto mannual switch complete all as specified and as directed. 3 Each
14 10 Supply and fix in replacement high and low voltage indicator complete all as specified and as directed. 3 Each
15 11 Supply and fix in replacement of gear suitable for voltage stabilizer of any capacity and make complete all as specified and as directed. 1 Each
16 12 Supply and fix in replacement of PCB holders suitable for voltage stabilizer of any capacity and make complete all as specified and as directed. 2 Each
17 13 Supply and fix in replacement push button suitable for voltage stabilizer of any capacity complete all as specified and as directed. 2 Each
18 14 Supply and fix in replacement potentio meter suitable for voltage stabilizer of any capacity complete all as specified and as directed. 2 Each
19 15 M&L for taking down burnt jumpers and M&L for jumper connection between GOD and drop out fuses and transformers with ACSR conductor of size 6 of 1/3.5mm n.exc. 2m long including aluminium socket clamped both ends and PVC sleeves complete all as directed. 4 Each job
20 16 S&F in repairs switch air break, gang operated HT 11 KV triple pole, mechanically operated, mounted on insulators and steel frame, vertically or horizontally with operating mechanism worked from ground level, for current rating up to 400 Amps complete including taking down existing unserviceable switch complete all as specified and as directed . 4 Each
21 17 S&F lightning arrester expulsion type complete with all fittings, transmission class, discharge capacity 65 KA suitable for earthed system 11 KV complete all as specified including dismantling existing arrester complete all as specified and as directed. 4 set of 3
22 18 Material & Labour for dismantling insulators any type any size from position without the disturbing to existing pole all as specified and directed. 12 Each
23 19 S & F shakle type porcelain,vitreous, white brown insulator including galvanised mild steel straps, washers, insulation bolts,washers and nuts for1100 volt and size of 75 x 90 mm including taking down complete all as specified and as directed at site. 12 Each
24 20 Supply and fix pin type porcelain, vitreous white , brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150 mm height , 150 mm dia for 11000 volts grade complete all as specified and as directed. 12 Each
25 21 S&F of Pole Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 (11 metres long) ( excavation & earth work, PCC and copping to be measured and paid seperately) complete all as specified and as directed 4 Each
26 22 M&L for defect rectification HT/LTcable laid in trenches by locating fault with the help of electronic fault locating machine comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator etc. including and additional excavation in normal alluvial strata required for exposing the cable fault ; removal of deteriorated portion of cable treating of cable and keeping the same ready for jointing work for cable of any size. The fault locating equipments will be brought to site within the hours of instruction from Engr-in-Charge as specified 5 Each
27 23 Supply and jointing heat shrinkable straight through joint suitable for HT 11KV XLPE cable of size 95 sqmm 3 core complete all as specified and as directed 4 Each
28 24 M&L for HT indoor termination cold shrinkable suitable for HT cable 11000 volts earthed grade 95 Sq mm 3 core complete all as specified and as directed. 4 Each
29 25 M&L for HT outdoor termination cold shrinkable suitable for HT cable 11000 volts earthed grade 95 Sq mm 3 core complete all as specified and as directed. 5 Each
30 26 S&F MCCB 400 A ,3 pole ,36 KA with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed .\nMake: Legrand/Siemns/ABB/Schneider 1 Each
31 27 S&F MCCB 250 A ,3 pole ,36 KA with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed .\nMake: Legrand/Siemns/ABB/Schneider 2 Each
32 28 S&F MCCB 200 A ,3 pole ,36 KA with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed . Make: Legrand/Siemns/ABB/Schneider 3 Each
33 29 S&F MCCB 100 A ,3 pole ,16 KA with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed . Make: Legrand/Siemns/ABB/Schneider 4 Each
34 30 M&L for Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6.0mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including using galvanised iron strip 32×6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel, earth plate surrounded by packed layer of char coal dust and common salt, 15cm thick all around bottom and top and watering pipe 20mm bore of GI light grade with funnel, wire mesh and 40 mm dia GI protection pipe medium grade all as shown in electrical plate No 3 of SSR Part-I and connected to earthing test point, main switch board and testing on completion including excavation, earth work concrete pit with 80mm thick RCC cover in RCC 1:2:4 type B-1 duly reinforced with MS bars 8mm dia @ 150C/C both ways and pit chamber in PCC 1:2:4 type B-1 with 2 Nos suitable lifting handles of 12mm MS bar complete all as specified and as directed. 10 Each
35 31 Supply and lay in trenches GI strip 25 mm x 4 mm galvanised iron strip for earth continuity earthing all as specified and as directed 30 RM
36 32 Ditto all as per item No 31 described here-in-before but 32 x 6 mm galvanised iron strip complete all as specified and as directed. 30 RM
37 33 Supply, laying and testing in replacement cable XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 Volts grade cross sectional area 3.5 core x 300 Sq mm. complete all as specified and as directed.\nNote : Provision of suitable double crimpped lugs and glands deemed to be included in quoted rates. 90 RM
38 34 Ditto all as per item No 33 described here-in-before but 3.5 core 150 sqmm 100 RM
39 35 Ditto all as per item No 33 described here-in-before but 3.5 core 120 sqmm 150 RM
40 36 Ditto all as per item No 33 described here-in-before but 3.5 core 95 sqmm 300 RM
41 37 Ditto all as per item No 33 described here-in-before but 3.5 core 70 sqmm 150 RM
42 38 Ditto all as per item No 33 described here-in-before but 3.5 core 50 sqmm 200 RM
43 39 Ditto all as per item No 33 described here-in-before but 4 core 25 sqmm 250 RM
44 40 Ditto all as per item No 33 described here-in-before but 4 core 16 sqmm 200 RM
45 41 S&F change over switch with sheet metal enclosure of size 200 Amps , 415 Volts, AC, 50 Hz with bus bar for connecting both incoming and outgoing cables with suitables connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed .\nMake: Cat No. L & T /BCH/GE/Havells 1 Each
46 42 S&F Indicating lamp 240 volts LED type complete all as specified and as directed 6 Each
47 43 Design Supply & Installation Of Complete Earthing Protection System With Copper Plate Of Size 300mm x 300mm x 2 mm Thick Buried Directly In Ground Connected To The Main Earth Lead Copper Strip 20mm x 3mm By Means Of 2 Set Accessories, Connected to Test Point Including Excavation in Rocky Type Of Soil, Providing Highly Treated Vegetable Soil, Earth Enhanced Compound Powder (ITPC EECP-15) Consists Of Copper Sulphate, Magnesium Sulphate, Graphite, Bentonite, Aluminium Silicate, Zinc Oxide & Iron Ore Alternate 15cm Layer Upto 15 Cm Above Top Edge Of Earth Plate, Construction Of PCC (1:2:4) type B-1 Pit RCC Cover and Including Testing On Completion Complete In All Respect. (Note (i)Earth Lead Are Included Upto Test Point and on testing Earth Resistance should be Less Than 5 ohm) .(ii)Copper strip for interconnection for plate and taking out 2 Nos of copper strip of size 20 x 3mm from earth pit to test point for a distance not less than 7.5 Mtr.\n 5 Each
48 44 S&F in repair mild steel hinges suitable for LT panel board shutters incl welding, riveting complete all as specified and as directed. 6 Each
49 45 Disconnecting and taking down existing bus bars 4 wire system from LT panel board cleaning with CTC applying with becktol solution, removing old insulation and providing new heat shrink insulating sleeves, connecting and fixing in the same panel with new nuts, bolts, washers of suitable size complete all as specified and as directed. 6 Each Set
50 46 Disconnecting and taking out old existing worn out control wiring connections incl cable lugs of LT panel board of 4 wire system and supply and connect with new cable PVC insulated, stranded copper conductor 2.5 sqmm incl new copper lugs and nuts, bolts, washers complete all as specified and as directed. 6 Each Panel
51 47 Disconnecting and taking out old existing worn out cable lugs, nuts, bolts, washers etc from LT panel board of 4 wire system (incomming and outgoing) and supply and connect with new aluminium lugs and nuts, bolts, washers etc complete all as specified and as directed. 6 Each Panel
52 48 Taking out old existing worn out neoprene gasket from shutters of LT panel board single door /double doors or openable on both sides and supply and fix new neoprene gasket complete all as specified and as directed. 6 Each Panel
53 49 M&L for Boring of holes under road, pavement,hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and as directed. 35 RM
54 50 Excavation in trenches n exc 1.5 wide and n exc 1.5 m in depth for foundation etc or for laying cable etc n exc 10 Sqm on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed. 150 Cum
55 51 Returning filling in including spreading, leveling, watering and well ramming in layers n exc 25 cm complete all as specified and as directed. 70 Cum
56 52 Removal of excavated material/surplus soil to a distance n exc 50m and depositing where directed at a level n exc 50m above the starting point complete all as specified and as directed. 80 Cum
57 53 Supply and filling river sand in trenches including spreading for cushioning of LT UG cable complete all as specified and as dirceted.\nNote : Punned down thickness shall be measured and paid . 30 Cum
58 54 M&L for sub class ‘B’ bricks old size laid flat dry in trenches over cable, across the direction of cable complete all as specified and as directed . 2000 Each
59 55 M&L for Foundation for Tubular swaged pole type Pole including excavation , getting out, pole foundation with PCC type D2 1:4:8 (with 40 mm graded aggregate). Coping of pole with PCC type C1 1:3:6 ( with 20 mm graded agregate) and removing surplus soil to a distance n.exc 50 m and making good surface complete all as specified and as directed . 2 Each Job
60 56 Taking down and dismantling HPSV street light fitting with GI bracket for 70/150/250 watt capacity of any make/type from pole/GI pipe unserviceable items to be kept in safe custody and taken as credit complete all as specified and as directed. 57 Each
61 57 Taking down of worn out wiring from street light fitting to junction box including conduit pipe complete all as specified and as directed. 16 Each
62 58 Taking down worn out PVC insulated copper cable 1.5 sqmm with steel rigid conduit complete all as specified and as directed. 200 RM
63 59 M&L for wiring with two run single core PVC insulated, stranded unsheathed copper cable conductor size 1.5 Sqmm and drawing through and including S&F steel rigid conduit not less than 20mm dia and fixed on pole including 1.5 Sqmm PVC insulated unsheathed stranded copper conductor cable connected to earth including connecting to earth dolly complete all as specified and as directed. 200 RM
64 60 Supply and Fixing LED street light luminaire IP-66 grade of proterction with 24 High power LED of 45 watt rating and extendable upto 48 watt rating with unique peanut lens to ensure uniform distribution complete all as specified and as directed . Make: CG or its equivalent in Wipro/Havells/Surya\n 45 Each
65 61 M&L for bracket for street light fitting made of 40mm bore light grade GI tube bent to shape required, fixed with and including MS flat iron clamps, bolts, nuts, washers duly painting the bracket with two coats of aluminium paint over a coat of zinc chrome primer complete including taking down the existing bracket and refixing and connecting up the light fitting etc all as directed. 16 Each Job
66 62 Supply and fixing weather proof street light junction box of size 300 x 200 x 105mm including MCB SP 6 Amps and connecting terminals 4 way and fixing with street light poles using necessary MS clamps, nuts, bolts washers, lugs for incoming and out going cables, gland for cable etc of suitable size complete all as specified and as directed. Make : Hensel/Sintex/Universal Switch Gear control \nNote : The rates quoted are inclusive of provision and fixing of suitable lugs and glands for cable connection. 16 Each
67 63 Supply and fix automatic timer switch pole mounted enclosure consisting of ON/OFF switch based on LUX level power contactor 40 Amps, 4 pole, MCB 40 Amps, TP - 03 Nos, enclosure made of rust proof, shock proof, conforming to IP -54 complete all as specified and as directed. Make : Kakatiya/Healer/Bajaj.\nNote: (i) Inlet/outlet connecting cable PVC insulated aluminium stranded conductor 6 Sqmm, 4 single core for incoming & outgoing up to 8 Mtr deemed to be included in the unit rate. (ii) Provn of glands and lugs shall be deemed to be included in the quoted rate. 1 Each
68 64 Repairs to Solar Geysers and Solar Street Lights deep feezer ,water cooler\nMaintenance/ servicing, cleaning Descaling and reconditioning of solar water heating system complete with of capacity 300 litres per day including with collector box of size (2120x1040x100 mm) 01 No of stainless steel tank by replacement of EPDM gasket ,nut & bolt ,GI fitting for existing water pipe line for inlet and outlet of stainless steel tank/ collector/water up to tank and making fully leak proof all as specified and as directed 2 Each Job
69 65 S&F in replacement of 300 LPD Stainless steel water heater tank with existing thickness of SS tank complete all as specified and as directed 1 Each Job
70 66 S&F in Repairs Stop valves, cast copper alloy, screwed down,high pressure,with crutch or butterfly handle,screwed both ends for iron pipe or for unions and fixed complete of size 40 mm complete all as specified and as directed 2 Each
71 67 S&F in Repairs Stop valves, cast copper alloy, screwed down,high pressure,with crutch or butterfly handle,screwed both ends for iron pipe or for unions and fixed complete of size 25 mm 2 Each
72 68 S&F in Repairs Stop valves, cast copper alloy, screwed down,high pressure,with crutch or butterfly handle,screwed both ends for iron pipe or for unions and fixed complete of size 20 mm 2 Each
73 69 S&F in Repairs Stop valves, cast copper alloy, screwed down,high pressure,with crutch or butterfly handle,screwed both ends for iron pipe or for unions and fixed complete of size 15 mm 8 Each
74 70 S&F in replacement of gun metal non return valve 15 mm dia complete all as specified and as directed 2 Each
75 71 S&F in replacement of gun metal non return valve 20 mm dia complete all as specified and as directed 2 Each
76 72 S&F in replacement of gun metal non return valve 25 mm dia all as specified and as directed complete all as specified and as directed 2 Each
77 73 S&F in replacement of brass flange threaded type suitable for 25 mm dia of hot water pipe solar hot water system including nut & bolt of suitable size complete all as specified and as directed 4 Each Job
78 74 S&F in replacement of post top luminaries fitting with all accessories suitable for solar street lighting system including 15 Watt LED+Driver + Dusk to Down Facility. complete all as specified and as directed 2 Each Job
79 75 Supply and fixing replacement of Solar Charge controller suitable for 120 AH Battery backup system for solar light fitting. The solar charge controller should be of Microprocessor Based MPPT with 96% efficiency with IP 65 protection with dimming feature (100% light output for first 06 hrs and 40% dim for next 06 hrs). The charge controller shall provide reverse polarity and short-circuit protection using auto-resettable fuse complete all as specified and as directed. 1 Each
80 76 S&F in repairs Lagging to pipes of sizes as per site in hot water supply all around with bounded mineral wool on outer side of hot water pipe line and covering with aluminium foils as per sample complete all as specified and as directed 20 RM
81 77 S&F in replacement rubber gasket of various sizes of Solar Geysers as per sample complete all as specified and as directed 2 Each Job
82 78 S&F in replacement U rubber for solar panel of Solar Geysers/Street Lights as per sample all as specified and as directed 2 Each Job
83 79 M&L for Servicing, Oiling, Greasing and Cleaning of window type/ split type AC with high pressure pump of any capacity, checking of defects/ leaking and adjusting setting to work and testing complete all as specified & directed. 65 Each Job
84 80 S&F for cutting of suction line and discharge line tubing of AC, front scaled unit de-scaling, flushing out condenser and cooling coil thoroughly and reconnecting with the seal unit and charging of gas with required qty of refrigerant for 1.5 ton Split/W/T type AC complete all as specified and as directed 30 Each
85 81 S&F for cutting of suction line and discharge line tubing of AC, front scaled unit de-scaling, flushing out condenser and cooling coil thoroughly and reconnecting with the seal unit and charging of gas with required qty of refrigerant for 2.0 ton Split/W/T type AC complete all as specified and as directed 25 Each
86 82 Supply & Fix spare parts of Air Conditioner etc.:-\nS&F in for replacement running capacitor of existing makes and capacity duly ISI marked for W/T and split type AC 1/1.5/2 Ton capacity complete all as specified and as directed.\n 25 Each
87 83 S&F in replacement of starting relay of existing makes and capacity duly ISI marked for W/T and split type AC 1/1.5/2 Ton capacity complete all as specified and as directed. 25 Each
88 84 S&F in for replacement starting capacitor of existing make and capacity duly ISI marked for window type A/C 1.5 ton and split type AC 1/1.5/2 ton capacity complete all as specified and as directed. 25 Each
89 85 S&F in replacement of Electronic control (PCB) of existing makes and capacity duly ISI marked for W/T and split type AC 1/1.5/2 Ton capacity complete all as specified and as directed. 3 Each
90 86 Repair to compressor off size of existing makes and capacity for W/T and split type AC 1/1.5/2 Ton capacity complete all as specified and as directed 3 Each
91 87 S&F in replacement of Thermostat switch of existing makes and capacity duly ISI marked for W/T and split type AC 1/1.5/2 Ton capacity complete all as specified and as directed 4 Each
92 88 Rewinding of blower motor of capacity 1.5/2.0 Ton complete all as specified & as directed. 2 Each
93 89 S&F in replacement of new rotary type AC compressor of window type/split AC with reconditioned & repaired compressor from authorized dealers of company in exchange including gas charging of capacity 1.5Ton capacity complete all as specified and as directed 5 Each
94 90 S&F in replacement of new rotary type AC compressor of window type/split AC with reconditioned & repaired compressor from authorized dealers of company in exchange including gas charging of capacity 2.0 Ton capacity ccomplete all as specified and as directed 5 Each
95 91 S&F in replacement of Evaporator coil complete all as specified and as directed 1 Each
96 92 S&F in replacement of Suction/Discharge valve complete all as specified and directed. 10 Each
97 93 S&F in replacement of Copper tube for 1.5 /2.0 Ton split AC 1/4 complete all as specified and as directed. 40 RM
98 94 S&F in replacement of Copper tube for 1.5 /2.00 Ton split AC 1/2 complete all as specified and as directed 40 RM
99 95 S&F in replacement of Copper tube cover complete all as specified and as directed 40 RM
100 96 S&F drain pipe rigid and flexible 20mm dia with clamps of suitable size as per site requirement complete all as specified and as directed 30 RM
101 97 S&F in replacement of insulation pipe size ¾” or 1” dia for split AC 1.5 / 2 Ton complete all as specified and as directed 20 RM
102 98 M&L for detection/rectification of leakage of gas in the system and gas charging in the system with appropriate quantity of gas including testing for smooth functioning of water cooler of capacity 40/80 ltr complete all as specified and as directed. \nNote:- (i) Unserviceable condensing coil if required shall be measured and paid separately. \n(ii) The cost of dismantling of unserviceable compressor if required deemed to be included in unit rate. \n(iii) Compressor shall be measured and paid separately under respective items of Sch "A" (iv) Refilling and toping up of refrigenrant (type and quantity) as required on site is deemed to be included in quoted rate. 4 Each
103 99 S&F compressor reciprocating type (hermetically) sealed for capacity 40/80 litre water cooler complete all as specified and as directed.\n 2 Each
104 100 S&F in repair of thermostat switch suitable for existing water cooler any make and capacity complete all as specified and as directed.\nMake: Renutrol/Indofos/Annapurna/Totaline 4 Each
105 101 S&F in replacement of starting relay and overload relay suitable for existing size and make water coolercomplete all as specified and as directed. Make: Epcos/Asian 4 Each
106 102 S&F in replacement of starting capacitor for water cooler suitable for existing size & make water cooler complete all as specified and as directed. 4 Each
107 103 S&F in replacement of running capacitor suitable for existing size & make water cooler complete all as specified and as directed. 2 Each
108 104 Dismantling of old defective condenser fan motor of water cooler of any make and capacity and refixing and testing the same after rewinding with super enameled copper wire of existing gauge or gauge as approved by Engineer-in-Charge including replacement of shaft/ bush etccomplete all as specified and as directed. 2 Each
109 105 S&F in replacement of fan blade of condenser motor of any make and capacity of water cooler complete all as specified and as directed. 2 Each
110 106 M&L for servicing of deep freezer any capacity and size by cleaning greasing including painting with one coat of super synthetic enameled paint including preparation of surfaces complete all as specified and as directed. 1 Each
111 107 S&F starting relay of deep freezer of any size & make complete all as specified and as directed. 1 Each
112 108 M&L for gas charging in deep freezer any make and capacity including testing of leakage complete all as specified and as directed. 1 Each
113 109 S&F of thermostat switch for deep freezer any make & capacity complete all as specified and as directed. 1 Each
114 110 Repair and maintenance, refrigerator of any capacity including replacement of following UNSV Parts starting relay - 01 No., over load relay-01 No, capacitor 20 mfd -01No, thermostate switch - 01 No, Door rubber beeding set - 01 Set complete all as specified and as directed. 4 Each
115 111 S&F in replacement of Aluminium Cable lugs/Thimbles upto size 16 to 25 sqmm complete all as specified and as directed 40 Each
116 112 S&F in replacement of Aluminium Cable lugs/Thimbles of size 35 to 50 sqmm complete all as specified and as directed 40 Each
117 113 S&F in replacement of Aluminium Cable lugs/Thimbles of size 70 to 120 sqmm complete all as specified and as directed 40 Each
118 114 Supply and jointing straight through joint suitable for LT 415 Volt XLPE cable of size 25 to 120 Sq mm 3.5 core complete all as specified and as directed . 5 Each
119 115 Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 core 95 sqmm complete all as specified and as directed. 245 RM
120 116 Supply and laying reinforced precast concrete cable cover class HV type-1, flat size 300mmx180mmx40mm complete all as specified and as directed. 25 Each
121 117 M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint complete all as specified and as directed 1 Quintel
122 118 Supply and fix GI pipe light grade of following sizes for cable protection in trenches/ at PCC poles for loopin/ loopout of cable and cable entry at bldg/block end,all as per specified and as directed.
123 118.01 100 mm dia 50 RM
124 118.02 80 mm dia 30 RM
125 118.03 50 mm dia 30 RM
126 119 M&L for 2.5 cm consolidated thickness bituminous mastic wearing course/mastic flooring with industrial bitumen of grade 80/25 prepared by using mastic cooker and laid to required level & slope including providing antisiked surface with bitumen pre coated fine fine graded hard stone chipping of approved size at the rate of 0.001 Cum per squire meter and at approximate spacing of 30 cm center in both direction, pressed into surface (Produst surface) 1mm to 4mm over mastic surface including applying the wearing coat of paving bitumen 80/100 @ 10 Kg of bitumen per 10 sqm area of road before applying the wearing coat complete all as specified and as directed 10 Sqm
127 120 M&L for painting of steel tubular pole including cable protection pipe and all iron parts of 9/11 mtr long pole complete with 2 coats of aluminium paint after cleaning all rust and dust and preparing surface with wire brush and including strips of white and blue colour of synthetic enamel paint up to the height of 1.5 mtr from the bottm of the pole complete all as specified and as directed.\nMake : Nerolac/Asian paint 35 Each
128 121 M&L for painting of PCC poles including cable protection pipe and all iron parts of 9/11 mtr long pole complete with 2 coats of paint after cleaning all rust and dust and preparing surface with wire brush and including strips of white and blue colour of synthetic enamel paint up to the height of 1.5 mtr from the bottm of the pole complete all as specified and as directed.\nMake : Nerolac/Asian paint 10 Each
129 122 Supply and Fixing in repair LED flood light luminaire IP-66 grade of proterction LED of 120 watt rating with unique peanut lens to ensure uniform distribution complete all as specified and as directed . Make: CG or its equivalent in Wipro/Havells/Surya\n 12 Each