As And As To Diving And Rcc Block Bldg No P 151 Provision Of Divers Briefing And Rest Room At Ins Karna Provision Of 2 Nos Parking Sheds In New Training Block And Beside Cheetah Hanger With Hard Standing And 3 Ft Height Boundary Wall In Three Sides O, INS Kalinga-Andhra Pradesh

Military Engineer Services-MES has published As And As To Diving And Rcc Block Bldg No P 151 Provision Of Divers Briefing And Rest Room At Ins Karna Provision Of 2 Nos Parking Sheds In New Training Block And Beside Cheetah Hanger With Hard Standing And 3 Ft Height Boundary Wall In Three Sides O. Submission Date for this Tender is 30-07-2019. Civil Work Tenders in INS Kalinga Andhra Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

21175411
As And As To Diving And Rcc Block Bldg No P 151 Provision Of Divers Briefing And Rest Room At Ins Karna Provision Of 2 Nos Parking Sheds In New Training Block And Beside Cheetah Hanger With Hard Standing And 3 Ft Height Boundary Wall In Three Sides O
Open Tender
Indian
Andhra Pradesh
INS Kalinga
30-07-2019

Tender Details

As And As To Diving And Rcc Block Bldg No P 151 Provision Of Divers Briefing And Rest Room At Ins Karna Provision Of 2 Nos Parking Sheds In New Training Block And Beside Cheetah Hanger With Hard Standing And 3 Ft Height Boundary Wall In Three Sides O

Key Value

Document Fees
INR 500 /-
EMD
INR 78000.0 /-
Tender Value
INR 39 Lakhs /-

BOQ Items

Sl. No. Item Description Item Code / Make Quantity Units
1 1 Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed by the Engineer-in-Charge. 1.8 Cu.m.
2 2 Surface excavation n. exc. 30cm deep and averaging 15cm deep and getting out in any type of soil complete all as specified and as directed by the Engineer-in-Charge. 170 Sq.m.
3 3 Excavation in trenches n. exc.1.5m wide and n. exc. 1.5m in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n. exc. 10 Sq.m. on plan and n. exc. 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed by the Engineer-in-Charge. 24.48 Cu.m.
4 4 Excavation in trenches n. exc.1.5m wide and n. exc. 1.5m in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n. exc. 10 Sq.m. on plan and n. exc. 1.5m in depth and getting out in hard/dense soil complete all as specified and as directed by the Engineer-in-Charge. 104.91 Cu.m.
5 5 All as per Item No.4 but depth exc. 1.50m but n. exc. 3.0m. 12 Cu.m.
6 6 Returning, filling in, including spreading, levelling, watering and well ramming in layers n. exc. 25cm complete all as specified and as directed by the Engineer-in-Charge. 92.7 Cu.m.
7 7 M&L for moorum/red bajri filling in floors or pavings, laid in layers n. exc. 15cm thick, spread, levelled and rammed including watering complete all as specified and as directed by the Engineer-in-Charge. 69 Cu.m.
8 8 Removing excavated soil to a distance n. exc. 50m and depositing where directed at a level n. exc. 1.5m above the starting point complete all as specified and as directed by the Engineer-in-Charge. 44.6 Cu.m.
9 9 M&L for hardcore of gauge n. exc. 63mm, deposited, spread and levelled in layers n. exc. 15cm thick, watered and rammed to a true surface complete all as specified and as directed by the Engineer-in-Charge. 55 Cu.m.
10 10 M&L for PCC 1:4:8 type D2 (Using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed by the Engineer-in-Charge. 9.2 Cu.m.
11 11 M&L for RCC M-30 design mix controlled concrete (Using 20mm graded granite stone aggregate) as in footings, plinth beams and the like complete all as specified and as directed by the Engineer-in-Charge. 29 Cu.m.
12 12 M&L for RCC M-30 design mix controlled concrete (Using 20mm graded granite stone aggregate) as in columns and pillars complete all as specified and as directed by the Engineer-in-Charge. 20.3 Cu.m.
13 13 M&L for RCC M-30 design mix controlled concrete (Using 20mm graded granite stone aggregate) as in lintel beams, roof beams and the like complete all as specified and as directed by the Engineer-in-Charge. 12 Cu.m.
14 14 M&L for RCC M-30 design mix controlled concrete (Using 20mm graded granite stone aggregate) as in slabs supported on walls and the like complete all as specified and as directed by the Engineer-in-Charge. 30 Cu.m.
15 15 M&L for brickwork with flyash bricks, straight or curved on plan exc. 6m mean radius built in cement mortar 1:6 complete all as specified and as directed by the Engineer-in-Charge. 73 Cu.m.
16 16 Use and waste of form work to sides of foundation/ footings, plinth beams and similar work for rough finished surfaces complete all as specified and as directed by the Engineer-in-Charge. 131 Sq.m.
17 17 Use and waste of form work to sides of columns and pillars for for fair finished surfaces complete all as specified and as directed by the Engineer-in-Charge. 237 Sq.m.
18 18 Use and waste of form work to sides and bottom of lintel beams and roof beams for for fair finished surfaces complete all as specified and as directed by the Engineer-in-Charge. 116 Sq.m.
19 19 Use and waste of form work to soffits of suspended slabs such as roof slabs, floors slabs, landings and similar work, n. exc. 200mm thick for fair finished surfaces complete all as specified and as directed by the Engineer-in-Charge. 200 Sq.m.
20 20 S&F reinforcement TMT steel bars of 10mm dia. and over, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia. or securing with clips or welded complete all as specified and as directed by the Engineer-in-Charge. 5300 Kg
21 21 All as per item No.20 above but 6 to 8mm dia. 2700 Kg
22 22 All as per item No.20 above but 5mm dia. and over upto and including 10mm dia. as in stirrups, spacers and binders. 1450 Kg
23 23 S&F mild steel bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required, hooks (stay), heavy, for large gates; hook and pintle hinges, large hasps and staples, chains, hand made sliding bolts, clamps; hold fasts, wall ties, hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and as directed by the Engineer-in-Charge. 20 Kg
24 24 S&F mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe 410 -W (Gde- E- 250) quality-A complete all as specified and as directed by the gineer-in-Charge. 570 Kg
25 25 S&F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St.-240 and is painted one shop coat of zinc chromate primer paint (including preparation of surface) at sontractor’s workshop before fabrication complete all as specified and as directed by the Engineer-in-Charge. 3600 Kg
26 26 S&F mild steel roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. complete all as specified and directed by Engineer-in-Charge. 1200 Kg
27 27 S&F mild steel stairs (framed) including, stringers, treades, landing, balusters, hand rails etc. including cleats, brackets, etc. complete all as specified and directed by Engineer-in-Charge. 700 Kg
28 28 S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed by the Engineer-in-Charge. 270 Sq.m.
29 29 S&F pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed by the Engineer-in-Charge. 28 Sq.m.
30 30 M&L for 75mm thick PCC 1:3:6 type C2 (Using 40mm graded stone aggregate) as in plinth protection complete all as specified and as directed by the Engineer-in-Charge. 40 Sq.m.
31 31 M&L for 75mm thick PCC 1:2:4 type B2 (Using 40mm graded granite stone aggregate) as in floors, pavements, hard standing etc., and finishing concrete surface even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge. 324 Sq.m.
32 32 M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces in CM 1:6 and finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge. 367 Sq.m.
33 33 M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces in CM 1:4 mixed with water proofing compound as per manufacturer's instructions finishing the surface even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge. 113 Sq.m.
34 34 M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces in CM 1:4 and finished fair and even complete all as specified and as directed by the Engineer-in-Charge. 285 Sq.m.
35 35 M&L for rendering 5mm thick on fair faces of concrete surfaces of ceilings in CM 1:3 and finished even and smooth with out using extra cement complete all as specified and directed by the Engineer-in-Charge. 200 Sq.m.
36 36 M&L for preparation of new plastered surfaces and applying three coats of white wash on walls complete all as specified and as directed by the Engineer-in-Charge. 107 Sq.m.
37 37 M&L for preparation of new plastered surfaces of ceilings and applying two coats of oil bound distemper over one coat of primer complete all as specified and as directed by the Engineer-in-Charge. 200 Sq.m.
38 38 M&L for preparation of new plastered surfaces and applying two coats of plastic emulsion over one coat of primer including 2mm thick wall care putty on walls complete all as specified and as directed by the Engineer-in-Charge. 285 Sq.m.
39 39 M&L for preparion of new plastered surfaces of walls and applying two coats of weather proof exterior emulsion over one coat of primer complete all as specified and as directed by the Engineer-in-Charge. 373 Sq.m.
40 40 M&L preparation of new or previously untreated steel surfaces of any description, n. exc. 10cm in width or girth when unconnected with other painting or when painted in a different tint and applying two coats of synthetic enamel paint over a priming coat of red oxide zinc chrome primer complete all as specified and directed by the Engineer-in-Charge. 180 Sq.m.
41 41 M&L for concealed point wiring PVC insulated and unsheathed cable with 2 run of 1.5 Sq.mm. FRLSH copper conductor single core multistranded 1100 Volt grade confirming to IS 694 drawn through PVC conduit of suitable size concealed metal box and 1.5 Sq.mm. earth wire copper insulated wire connected to common earth dolly for one LED light/ceiling fan/exhaust fan point controlled by one No. one way switch or one 3 pin socket out let 5 Amps switch socket controlled by one No. one way switch on independent board complete all as specified and as directed by the Engineer-in-Charge. 30 Point
42 42 M&L for concealed point wiring PVC insulated and unsheathed cable with 2 run of 1.5 Sq.mm. FRLSH copper conductor single core multistranded 1100 Volt grade confirming to IS 694 drawn through PVC conduit of suitable size concealed metal box and 1.5 Sq.mm. earth wire copper insulated wire connected to common earth dolly for one LED light point controlled by two Nos. two way switches complete all as specified and as directed by the Engineer-in-Charge. 2 Point
43 43 M&L for concealed point wiring PVC insulated and unsheathed cable with 2 run of 2.5 Sq.mm. FRLSH copper conductor single core multistranded 1100 Volt grade confirming to IS 694 drawn through PVC conduit of suitable size concealed metal box and 2.5 Sq.mm. earth wire copper insulated wire connected to common earth dolly for 15 Amps switch socket complete all as specified and as directed by the Engineer-in-Charge. 2 Point
44 44 M&L for concealed point wiring PVC insulated and unsheathed cable with 2 run of 4 Sq.mm. FRLSH copper conductor single core multistranded 1100 Volt grade confirming to IS 694 drawn through PVC conduit of suitable size concealed metal box and 4 Sq.mm. earth wire copper insulated wire connected to common earth dolly for metal clad power socket complete all as specified and as directed by the Engineer-in-Charge. 4 Point
45 45 M&L for surface point wiring with 1.5 Sq.mm. PVC insulated, 1100 Volts, unsheathed single core multi stranded FRLSH copper conductor with necessary earth continuity conductor of 1.5 Sq.mm. PVC insulated copper conductor 1100 Volts grade, drawn through PVC conduit of suitable size duly fixing on wall/ceiling connected to common earth dolly for one LED light point controlled by one 5 amps one way switch complete all as specified and as directed by the Engineer-in-Charge. 10 Point
46 46 S&F switch piano flush type single pole one way 6 Amps, 230 Volts, 50 Hz complete all as specified and as directed by the Engineer-in-Charge. 36 Each
47 47 S&F switch piano flush type two way 6 Amps, 230 Volts, 50 Hz complete all as specified and as directed by the Engineer-in-Charge. 4 Each
48 48 S&F switch socket combination with indication lamp 2 in1 3 pin 5 Amps 240 Volts flush type multi purpose complete all as specified and as directed by the Engineer-in-Charge. 4 Each
49 49 S&F switch socket combination with indication lamp 5 in 1 3 pin 5/15 A 240 Volts flush type multi purpose complete all as specified and as directed by the Engineer-in-Charge. 2 Each
50 50 S&F ceiling rose surface type bakalite 2/3 terminals complete all as specified and as directed by the Engineer-in-Charge. 36 Each
51 51 S&F MCB SP 6 to 40 Amps, 230 Volts, 'B'series complete all as specified and as directed by the Engineer-in-Charge. 10 Each
52 52 S&F MCB SPN 6 to 40 Amps, 230 Volts, 'B' series complete all as specified and as directed by the Engineer-in-Charge. 1 Each
53 53 S&F MCB DP 32 Amps, 230 Volts, 'B' series complete all as specified and as directed by the Engineer-in-Charge. 2 Each
54 54 S&F MCB TPN 63 Amps, 230 Volts, 'B' series complete all as specified and as directed by the Engineer-in-Charge. 1 Each
55 55 S&F sheet steel enclosure MCB DB TPN 4 way with 200 Amps rated bus bar horizantal type 230 Volts IP 43 protection with double metal door complete all as specified and as directed by the Engineer-in-Charge. 1 Each
56 56 S&F sheet steel enclosure MCB DB SPN 4 way with 200 Amps rated bus bar horizantal type 230 Volts IP 43 protection with double metal door complete all as specified and as directed by the Engineer-in-Charge. 1 Each
57 57 S&F single pole and neutral sheet metal enclosure with a two pin and earth plug and socket 240 V, 50 Hz complete with one single pole MCB 20 A complete all as specified and as directed by the Engineer-in-Charge. 4 Each
58 58 S&F retrofit 20 Watt linear LED T8 tubular lamp with extruded aluminium body, PC diffuser and inbuilt driver alonge with LED batten suitable for T8 LED lamps 230 Volts, 50 Hz complete all as specified and as directed by the Engineer-in-Charge.\nMake: Crompton Cat. Part No.LTT8-20 for the lamp and DMLN1LT8-16 for the batten or equivalent in Philips/C&S/ Havells/Wipro 22 Each
59 59 S&F LED street light fitting 30 W, IP 65, 230 Volts, 50 Hz with compact size and robust design complete all as specified and as directed by the Engineer-in-Charge.\nMake: Crompton Freedom+ model Cat. Part No.LSTS-30-CDL or equivalent in Philips/C&S/Havells/Wipro 2 Each
60 60 S&F ceiling fan 1200mm sweep, BEE 5 star rated 380 Rpm with high air delivery at low voltages, with double ball bearing in ivory gold/white colour including fixing of regulator, down rod of 19mm dia 300mm long and connecting up with flexible 3 core 1.5sq.mm twisted copper cable from terminal point to ceiling fan complete all as specified and as directed by the Engineer-in-Charge. 12 Each
61 61 S&F house service bracket 1.5 mtrs. long GI pipe 40mm dia. medium grade two Nos. 90 degrees bends MS hook and stay or guy complete all as specified and as directed by the Engineer-in-Charge. 2 Each
62 62 Supply and laying LT underground cable XLPE insulated and sheathed armoured cable 1100 Volts 2 core 6 Sq.mm. aluminium conductor in trenches/poles and connecting with all accessories complete all as specified and as directed by the Engineer-in-Charge. 183 Rm
63 63 Supply and laying LT underground cable XLPE insulated and sheathed armoured cable 1100 Volts 4 core 25 Sq.mm. aluminium conductor in trenches/poles and connecting with all accessories complete all as specified and as directed by the Engineer-in-Charge. 23 Rm
64 64 Supply and spread clean river sand as cable cushioning for protection of cable to be laid in trenches all as per SSR Part-I complete all as specified and as directed by the Engineer-in-Charge.\nNote: Only punned thickness of 18cm will be measured for the purpose of payment. 8.9 Cu.m.
65 65 M&L common burnt bricks, sub class 'B' of size 230x115x 75mm for cable protection complete all as specified and directed by Engineer-in-Charge. 1100 Each
66 66 Supply and laying steel tubing galvonised 20mm bore light grade with all fitting for cable protection complete all as specified and as directed by the Engineer-in-Charge. 10 Rm
67 67 Supply and laying steel tubing galvonised 40mm bore light grade with all fitting for cable protection complete all as specified and as directed by the Engineer-in-Charge. 6 Rm