Construction Of Modern Factory Cum Lab For Homco At Valiyakalavoor , Alappuzha-Electrical Works As Per Cgmp Norms

Issued by Cooperative · HOMCO, Valiya Kalavoor, Alappuzha, Kerala, Kerala
Tender Value
4.20 Crore
Estimated cost
Bid Submission
14 Aug 2019
0 days left
EMD
1 Lakhs
Bank guarantee accepted
Document Fee
8400
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
HOMCO, Valiya Kalavoor, Alappuzha, Kerala → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Construction Of Modern Factory Cum Lab For Homco At Valiyakalavoor , Alappuzha-Electrical Works As Per Cgmp Norms

BOQ

Sl.No. Item Description Item Code / Make Quantity Units
1 1 APPENDIX A EB RECEIVING, METERING & CONSUMER RECEIVING
2 1.01 EB RECEIVING :- RING MAIN UNIT:-Supply, Installation, testing and commissiong of 1 No. 11KV, 630A, Motor Operator, Compact outdoor type extensible RING MAIN UNIT with vacuum circuit breaker and CTC(E) as per the Electrical Inspectrate/KSEB Technical specifications and standards both side extensible non drawout type gas insulated RMU. The RMU consists of 3 Nos of 630A, 25KA Air Braker/Load breaker/Isolator with suitably inter locked earth switch. The rate is inculssive of all taxes and duties and transportation insurance, lift lead and position and supervision charges, testing charges. The associated civil works for positioning the RMU with suitable RCC foundation etc complete as referred. item1 1 Set
3 1.02 EB METERING :- Supply, installation & testing commissioning of Outdoor type 11KV HT meter panel HT CT & PT, TTB, Wiring etc. complete in all respects (11KV HT Electronic Trivector Meter Will be Supplied by Local Electricity Board) item2 1 Set
4 1.03 Consumer Receiving - 11KV VCB :- Supply, Unloading, shifting, Installation, Testing and Commissioning of Outdoor Type, 11KV HT PANEL , Indoor/Outdoor Type suitable for 11KV, 630A, 350 mva, 3PHASE, 50 Hz, consisting of single 11KV Vaccum Circuit Breakers & Panel Boards made of sheet steel clad dust & vermin proof , free floor standing incluiding existinng base channels etc., with all accessories like power pack/battery charger as required for satisfactory operation in compliance with the statutory Electrical authorities and RRL Technical specifications. item3 1 Set
5 1.04 Package SUBSTATION 11KV/ 1250 kVA DRY Type/INDOOR Type :- Supply, Unloading, shifting, Installation, Testing and Commissioning of 11KV PACKAGE SUBSTATION Indoor / Outdoor Type suitable for 11KV, 630A, 350 mva, 3PHASE, 50 Hz, consisting of single 11KV Vaccum Circuit Breakers, 1250 kVA Transformer & Panel Boards made of sheet steel clad dust & vermin proof , free floor standing incluiding existinng base channels etc., with all accessories like power pack/battery charger as required for satisfactory operation in compliance with the statutory Electrical authorities & Specfications (Note: Contractor should quote along with Foundation works)\n item4 1 Set
6 2 H.T. CABLE:- Supply and Laying of HT-XLPE insulated FR PVC outer sheathed, inner extruded PVC SHEATH, 3CORE, ARMOURED, stranded ALUMINIUM conductor cables of cables per IS. The cable shall either be 'laid 'in trench 1.1 M wide 0.75m deep / RCC 'Hume pipe of size 250mm / ready-made cable tray with proper clamping. Rate shall be inclusive of cable tags, clamps, etc. Cable tags shall be of aluminium engraved sheets (2mm)tied at regular intervals of not less than 10mtrs.
7 2.01 3C X 300 Sq. mm 11KV Earthed XLPE Aluminium Armoured cable. :- Supplying, termination, testing and commissioning of following indoor/outdoor type cable end termination suitable for 11 KV (E) aluminum conductor XLPE cable with heat shrinkable jointing kit, cable lugs etc. complete as required. item5 350 Mtr
8 2.02 3C x 300 sq.mm. XLPE insulated Al. Ar. Cable (Outdoor Type) item6 1 Nos
9 2.03 3C x 300 sq.mm. XLPE insulated Al. Ar. Cable (Indoor Type) item7 3 Nos
10 2.04 Preparation of TRENCH for cable laying in 1.0m deep x 500mm wide; with 100mm sand cushioning above and below the cable: 450L X 175W X 35Hmm RCC tiles inclusive of excavation work. item8 200 Mtr
11 3 RESIN CAST BUSDUCT :- Supplying, Installing, Suspension Testing & Commissioning of 2500A, Indoor, Sandwich type Aluminium bus duct for use on 3 Phase, 4 Wire, 415 Volts, 50Hz AC supply with metal clad enclosures made of 2 mm thick steel sheet duly powder coated in convinent section complete with 4 Nos. Aluminium bus bars, necessary joints, elbow joints and, expansion joints, fire barriers at regular interval of 3 Meter, Continuous earthing with two nos. Copper strip of suitable size (one on each side) as required. Between Package Substation to Main LT Panel. Sandwich type Aluminium Busduct between (IP 65 )
12 3.01 Straight Length item9 10 Mtr
13 3.02 Vertical Bends item10 2 Nos
14 3.03 Horozontal Bends. item11 2 Nos
15 3.04 Flange End. item12 2 Nos
16 3.05 Adopter Boxes. item13 2 Nos
17 3.06 Copper Flexible. item14 5 Mtr
18 3.07 Suitable size flexible braided copper item15 2 Mtr
19 4 DIESEL GENERATOR SET:- Supply, Installation, testing and commissioning of following capacity of three phase D.G. Set with standard specification and Acoustic Enclosure on the foundation provided near the Substation. (Civil works for the foundation will be done by the Owner). Engine: - 6 cylinder, In-line, 4 stroke, radiator cooled engine,?? Full Authority Electronic Engine ? Well designed air handling system with — Dry type, Replaceable paper element air cleaner with restriction indicator — Air to air aftercooling — Optimised turbocharger for increased altitude capabilities ? Best in class fuel economy with — Modular Commom Rail (MCRS) fuel system with A1 class electronic governing — Dual fuel filter system: Pre filter including water separator and Water In Fuel (WIF) sensor and main filter ?? Standard integral set-mounted radiator system, designed and tested for 50°C ambient temperature ?? Venturi combo spin on lube oil filter ?? Plate type lube oil cooler ?? First fill of lube oil and coolant ?? Electrical starter motor with soft start engagement feature ?? Battery charging alternator 2 x 12 V DC atteries. Alternator:-?Brushless Type, Screen protected, Revolving field, Self excited alternator conforming to IS/IEC 60034-1 ?? 3 Phase reconnectable winding with 12 terminals brought out for connection ?? Better motor starting capability ?? Best in class efficiency Compact design with sealed bearings for longer life and lesser maintenance Impregnation on all wound components for better mechanical strength . Control Panel : - Engine monitoring and annunciation Panel
20 4.01 500 kVA item16 1 Nos
21 4.02 750 kVA item17 1 Nos
22 5 Exhaust Piping
23 5.01 Supply & installation of 10\" Class B Pipe including flanges, nuts bolts & Gaskets after silencer. item18 15 Mtr
24 5.02 Supply & installation of 8\" Class B Pipe including flanges, nuts bolts & Gaskets after silencer. item19 15 Mtr
25 5.03 Supply & installation of 50 mm thk. Insulation with rockwool density-64 kg/m3 and 24 guage aluminium cladding for above exhaust pipe item20 30 Mtr
26 5.04 Structural Steel support to support the exhaust pipes upto about 15 mtrs stack height with necessary steel. The final resposibility of the stability of the structure shall remain with the vendor.\nThe DG stack is proposed to be self standing chimney. The necessary steel structure to support the chimney including frame is included in the scope of works. Vendor to submit the drawing showing the arrangement for support of structure.\n(The approximate height of the stack is 15 Mts) item21 2500 Kg
27 6 MAIN LT PANEL & SUB PANELS :-Fabrication, conveyance, supply, installation, testing and commissioning of self-supported, free standing powder coated cubicle type, 415V, 36 kA Switch Board of CRCA No.14/16 gauge sheet steel construction with cable entry facility at top/bottom. Cable alley, switchgear compartment, meter chamber, bus bar chamber etc. shall be fully segregated & compartmentalized. Shrouding of live parts shall be with 3 mm FRP and two fastener screws and chamber partition at dropper connections with 3 mm FRP. Control wiring shall be with 2.5 sq. mm copper cable of 1100 volt grade for CT leads and 1.5 sq. mm for voltage leads with 2A SP MCB. All meters, connectors, lamps etc. shall have safe finger proof terminals. Doors shall be provided with 4 sq. mm flexible copper and socketed earth leads of green/green and yellow stripped PVC insulation. All copper joints shall be tinned. Knock- outs of proper diameter shall be provided on glanding plates. Ring type CTs shall be rigidly fixed to the cable chamber walls so that socketed cable cores can be easily taken through the CTs. The height of the operating handle of any switch gear shall not be more than 1.8 metres or less than 0.6 metres from bottom level of the switch board. All MCCB's are rotary operated handle with spreader terminals. Painting : Powder coated after seven tank metal treatment. Colour - Admiralty Grey as per I.S.S (RAL 7032). Enclosure : Degree of Protection - IP 54 or above. Doors / Cover : Doors with concealed hinges & bolted cover for bus chamber.Labelling : All incomers and outgoings shall be labelled. PVC identification ferrule numbers shall be used for all internal wiring. The panel manufactrere shoud have CPRI and ISO certification. MAIN LT PANEL:-
28 6.01 CRCA Sheet 2mm thickness item22 780 Sqft
29 6.02 Heat Shrinkable Sleeved Aluminium Bus bar item23 63850 Cu.Cm
30 6.03 KSEB Incomer : 2000A, 50kA, 4P, EDO Microproceesor based ACB with all protections restricted Earth fault relay, under and over voltage protection relays. item24 1 Nos
31 6.04 Earth Fault Relay with control accessories item25 1 Nos
32 6.05 REF Relay with suitable ID/Class resin cast CT item26 1 Nos
33 6.06 Multi Function Meter with RS 485 port item27 1 Nos
34 6.07 Ammeter with suitable ID/Class resin cast CT item28 1 Set
35 6.08 RYB Indication with control MCBs item29 1 Set
36 6.09 DG1 Incomer : 1250A, 50kA, 4P, EDO Microproceesor based ACB item30 1 Nos
37 6.1 Control Relays and metering equipments for GCP as per standard item31 1 Set
38 6.11 Multi Function Meter with RS 485 port item32 1 Set
39 6.12 suitable ID/Class resin cast CT item33 1 Set
40 6.13 DG2 Incomer : 800A, 50kA, 4P, EDO Microproceesor based ACB item34 1 Nos
41 6.14 Control Relays and metering equipments for GCP as per standard item35 1 Set
42 6.15 Multi Function Meter with RS 485 port item36 1 Set
43 6.16 suitable ID/Class resin cast CT item37 1 Set
44 6.17 Bus Coupler : 2000A, 50kA, 4P, EDO Thermal magnetic rels ACB item38 1 Nos
45 6.18 PLC based AMF with load sharing System item39 1 Set
46 6.19 Outgoings : 1000A, 4P, 50kA ACB Thermal rels item40 2 Nos
47 6.2 630A, 4P, 50kA MCCB Thermal rels item41 1 Nos
48 6.21 400A, 4P, 50kA MCCB Thermal rels item42 5 Nos
49 6.22 2000/5A, CL:1, 10/15VA, resin cast CT (APFC) item43 1 Nos
50 6.23 Earth Bus : 32 X 6 mm Copper item44 6 Mtr
51 6.24 25 X 6 mm Copper item45 3 Mtr
52 6.25 25 X 3 mm Copper item46 3 Mtr
53 6.26 100 X 50MM C Channel MS item47 15 Mtr
54 6.27 Surge Protection Device:- The panel include pluggable type surge arrestor including additional DIN rail bar Class B+C / Class 1 + 2 as per IEC 61643 (IP 20) with potential free contact, thermal disconnector and provission for inbuilt common remote indication for defective arrestor to connect between lin and neutral and 1No. arrestor spark gap type to connect between neutral and earth of following ratng including base element and pluggable arrestors. Terminal voltage 230V, 50Hz, Type single MOV with builtin thermal fuse and cooling Gel (L - N) and spark gas encapsilated or non exhausting ( N - E). Lightning impulze current 37.5kA. (Make OBO Betterman or Mitsubishi) The Surge Protection Device should be installed in ROHS complied, distribution box, 5 division units, emty dimensions 190 x 150 x 125mm. item48 3 Nos
55 7 HVAC PANEL
56 7.01 CRCA Sheet 2 mm thickness item49 200 Sqft
57 7.02 CRCA Sheet 1.6 mm thickness item50 95 Sqft
58 7.03 Heat Shrinkable Sleeved Aluminium Bus bar item51 33370 Cu.Cm
59 7.04 Incomer : 1000A, 4P, 50kA ACB Thermal rels item52 1 Nos
60 7.05 Multi Function Meter with suitable rating resin cast CT item53 1 Set
61 7.06 RYB Indication with control MCBs item54 1 Set
62 7.07 Outgoings : 400A, TP, 35kA MCCB Thermal rels item55 3 Nos
63 7.08 250A, TP, 35kA MCCB Thermal rels item56 3 Nos
64 7.09 200A, TP, 35kA MCCB Thermal rels item57 2 Nos
65 7.1 160A, TP, 35kA MCCB Thermal rels item58 2 Nos
66 7.11 75 X 40MM C Channel MS item59 8 Mtr
67 7.12 Earth Bus : 25 X 6 mm Copper item60 2 Mtr
68 7.13 25 X 3 mm Copper item61 4 Mtr
69 8 POWER SWITCH BOARD - ( PSB )
70 8.01 CRCA Sheet 1.6mm thickness item62 115 Sqft
71 8.02 Heat Shrinkable Sleeved Aluminium Bus bar item63 9615 Cu.Cm
72 8.03 Incomer : 1000A, 4P, MCCB without release item64 1 Nos
73 8.04 Multi Function Meter with suitable rating resin cast CT item65 1 Set
74 8.05 RYB Indication with control MCBs item66 1 Set
75 8.06 Outgoings : 400A, 4P, 35kA MCCB Thermal rels item67 1 Nos
76 8.07 300A, TP, 35kA MCCB Thermal rels item68 1 Nos
77 8.08 200A, TP, 35kA MCCB Thermal rels item69 5 Nos
78 8.09 100A, TP, 35kA MCCB Thermal rels item70 1 Nos
79 8.1 75 X 40MM C Channel MS item71 8 Mtr
80 8.11 Earth Bus : 25 X 3 mm Copper item72 5 Mtr
81 9 AHU MAIN PANEL
82 9.01 CRCA Sheet 1.6mm thickness item73 120 Sqft
83 9.02 Heat Shrinkable Sleeved Aluminium Bus bar item74 5850 Cu.Cm
84 9.03 Incomer : 400A, TPN, MCCB without release item75 1 Nos
85 9.04 Multi Function Meter with suitable rating resin cast CT item76 1 Set
86 9.05 RYB Indication with control MCBs item77 1 Set
87 9.06 Outgoings : 200A, TP, MCCB Thermal rels item78 6 Nos
88 9.07 75 X 40MM C Channel MS item79 7 Mtr
89 9.08 Earth Bus : 25 X 3 mm Copper item80 3 Mtr
90 10 UTILITY PANEL
91 10.01 CRCA Sheet 1.6mm thickness item81 120 Sqft
92 10.02 Heat Shrinkable Sleeved Aluminium Bus bar item82 5700 Cu.Cm
93 10.03 Incomer : 400A, TPN, MCCB without release item83 1 Nos
94 10.04 Multi Function Meter with suitable rating resin cast CT item84 1 Set
95 10.05 RYB Indication with control MCBs item85 1 Set
96 10.06 Outgoings : 200A, TP, MCCB Thermal rels item86 1 Nos
97 10.07 100A, TP, MCCB Thermal rels item87 2 Nos
98 10.08 63A, TP, MCCB Thermal rels item88 5 Nos
99 10.09 200A, TPN, MCCB without release item89 4 Nos
100 10.1 75 X 40MM C Channel MS item90 8 Mtr
101 10.11 Earth Bus : 25 X 3 mm Copper item91 7 Mtr
102 11 PUMP PANEL
103 11.01 CRCA Sheet 1.6mm thickness item92 70 Sqft
104 11.02 Heat Shrinkable Sleeved Aluminium Bus bar item93 1570 Cu.Cm
105 11.03 Incomer : 160A, TPN, MCCB without release item94 1 Nos
106 11.04 RYB Indication with control MCBs item95 1 Set
107 11.05 Outgoings : 63A, TP, MCCB Thermal rels item96 7 Nos
108 11.06 25A, TP MCCB Thermal rels item97 1 Nos
109 11.07 75 X 40MM C Channel MS item98 6 Mtr
110 11.08 Earth Bus : 25 X 3 mm Copper item99 4 Mtr
111 12 AHU PANEL 1-3
112 12.01 CRCA Sheet 1.6mm thickness item100 500 Sqft
113 12.02 Heat Shrinkable Sleeved Aluminium Bus bar item101 10860 Cu.Cm
114 12.03 Incomer : 200A, TPN, Isolator item102 4 Nos
115 12.04 RYB Indication with control MCBs item103 4 Set
116 12.05 Outgoings : 100A, TPN, MCCB Thermal rels item104 8 Nos
117 12.06 32A, TPN MCCB Thermal rels item105 1 Nos
118 12.07 63A, TPN MCCB Thermal rels item106 2 Nos
119 12.08 75 X 40MM C Channel MS item107 17 Mtr
120 12.09 Earth Bus : 25 X 3 mm Copper item108 20 Mtr
121 13 COMPRESSOR PANEL
122 13.01 CRCA Sheet 1.6mm thickness item109 70 Sqft
123 13.02 Heat Shrinkable Sleeved Aluminium Bus bar item110 1800 Cu.Cm
124 13.03 Incomer : 200A, TPN, MCCB without release item111 1 Nos
125 13.04 RYB Indication with control MCBs item112 1 Set
126 13.05 Outgoings : 125A, TPN, MCCB Thermal rels with 40kW Star Delta Starter with remote PB item113 1 Set
127 13.06 100A, TPN, MCCB Thermal rels with 20kW Star Delta Starter with remote PB item114 1 Set
128 13.07 63A, TPN MCCB Thermal rels with provision for fixing Star Delta Starter item115 2 Set
129 13.08 75 X 40MM C Channel MS item116 5 Mtr
130 13.09 Earth Bus : 25 X 3 mm Copper item117 3 Mtr
131 14 APFC PANEL - 300kVAr
132 14.01 CRCA Sheet 1.6mm thickness item118 215 Sqft
133 14.02 Heat Shrinkable Sleeved Aluminium Bus bar item119 3430 Cu.Cm
134 14.03 Incomer : 630A, TPN, MCCB without release item120 1 Nos
135 14.04 Multi Function Meter with suitable rating resin cast CT item121 1 Set
136 14.05 RYB Indication with control MCBs item122 1 Set
137 14.06 Inteligent Power Factor correction Relay 12 STAGE item123 1 Nos
138 14.07 Outgoings : 125A, TP, MCCB Thermal rels item124 2 Nos
139 14.08 63A, TP, MCCB Thermal rels item125 7 Nos
140 14.09 32A, TP, MCCB Thermal rels item126 3 Nos
141 14.1 Capacitor duty contactor suitable for 50kVAr Heavy duty gas filled Capacitor. item127 2 Nos
142 14.11 Capacitor duty contactor suitable for 25kVAr Heavy duty gas filled Capacitor. item128 4 Nos
143 14.12 Capacitor duty contactor suitable for 20kVAr Heavy duty gas filled Capacitor. item129 3 Nos
144 14.13 Capacitor duty contactor suitable for 15kVAr Heavy duty gas filled Capacitor. item130 2 Nos
145 14.14 Capacitor duty contactor suitable for 10kVAr Heavy duty gas filled Capacitor. item131 1 Nos
146 14.15 50kVAr Heavy duty gas filled Capacitor and 7% series copper type reactor item132 2 Set
147 14.16 25kVAr Heavy duty gas filled Capacitor and 7% series copper type reactor item133 4 Set
148 14.17 20kVAr Heavy duty gas filled Capacitor and 7% series copper type reactor item134 3 Set
149 14.18 15kVAr Heavy duty gas filled Capacitor and 7% series copper type reactor item135 2 Set
150 14.19 10kVAr Heavy duty gas filled Capacitor and 7% series copper type reactor item136 1 Set
151 14.2 75 X 40MM C Channel MS item137 9 Mtr
152 14.21 Earth Bus : 25 X 6 mm Copper item138 8 Mtr
153 15 LIGHT SWITCH BOARD
154 15.01 CRCA Sheet 1.6mm thickness item139 125 Sqft
155 15.02 Heat Shrinkable Sleeved Aluminium Bus bar item140 3240 Cu.Cm
156 15.03 Incomer : 200A, TPN, MCCB without release item141 1 Nos
157 15.04 VAF Meter with suitable rating resin cast CT item142 1 Set
158 15.05 RYB Indication with control MCBs item143 1 Set
159 15.06 Outgoings : 32A, TP MCCB Thermal rels item144 12 Nos
160 15.07 75 X 40MM C Channel MS item145 7 Mtr
161 15.08 Earth Bus : 25 X 3 mm Copper item146 5 Mtr
162 16 SUB SWITCH BOARD - 1 ( SSB1 )
163 16.01 CRCA Sheet 1.6mm thickness item147 170 Sqft
164 16.02 Heat Shrinkable Sleeved Aluminium Bus bar item148 4900 Cu.Cm
165 16.03 Incomer : 200A, TPN, Switch Disconnector item149 1 Nos
166 16.04 VAF Meter with suitable rating resin cast CT item150 2 Set
167 16.05 RYB Indication with control MCBs item151 2 Set
168 16.06 Outgoings : 100A, TP MCCB Thermal rels item152 1 Nos
169 16.07 75A, TP MCCB Thermal rels item153 1 Nos
170 16.08 63A, TP MCCB Thermal rels item154 3 Nos
171 16.09 25A, TP MCCB Thermal rels item155 1 Nos
172 16.1 75 X 40MM C Channel MS item156 12 Mtr
173 16.11 Earth Bus : 25 X 3 mm Copper item157 7 Mtr
174 17 SUB SWITCH BOARD - 2 ( SSB2 )
175 17.01 CRCA Sheet 1.6mm thickness item158 125 Sqft
176 17.02 Heat Shrinkable Sleeved Aluminium Bus bar item159 3950 Cu.Cm
177 17.03 Incomer : 300A, TPN, Switch Disconnector item160 1 Nos
178 17.04 VAF Meter with suitable rating resin cast CT item161 1 Set
179 17.05 RYB Indication with control MCBs item162 1 Set
180 17.06 Outgoings : 100A, TP MCCB Thermal rels item163 1 Nos
181 17.07 63A, TP MCCB Thermal rels item164 5 Nos
182 17.08 32A, TP MCCB Thermal rels item165 2 Nos
183 17.09 75 X 40MM C Channel MS item166 7 Mtr
184 17.1 Earth Bus : 25 X 3 mm Copper item167 7 Mtr
185 18 SUB SWITCH BOARD - 3 ( SSB3 )
186 18.01 CRCA Sheet 1.6mm thickness item168 125 Sqft
187 18.02 Heat Shrinkable Sleeved Aluminium Bus bar item169 3950 Cu.Cm
188 18.03 Incomer : 400A, TPN, Switch Disconnector item170 1 Nos
189 18.04 VAF Meter with suitable rating resin cast CT item171 1 Set
190 18.05 RYB Indication with control MCBs item172 1 Set
191 18.06 Outgoings : 160A, TP MCCB Thermal rels item173 1 Nos
192 18.07 100A, TP MCCB Thermal rels item174 1 Nos
193 18.08 63A, TP MCCB Thermal rels item175 5 Nos
194 18.09 32A, TP MCCB Thermal rels item176 3 Nos
195 18.1 75 X 40MM C Channel MS item177 7 Mtr
196 18.11 Earth Bus : 25 X 3 mm Copper item178 7 Mtr
197 19 LIFT PANEL 1,2 & 3
198 19.01 CRCA Sheet 1.6mm thickness item179 45 Sqft
199 19.02 Heat Shrinkable Sleeved Aluminium Bus bar item180 1000 Cu.Cm
200 19.03 Incomer : 100A 4P MCB item181 1 Nos
201 19.04 Outgoings : 32A, 4P 300mA ELCB item182 8 Nos
202 19.05 25A, 2P 30mA ELMCB item183 3 Nos
203 19.06 6A, SP MCB item184 4 Nos
204 19.07 Earth Bus : 25 X 3 mm Copper item185 2 Mtr
205 20 SS ENCLOSURES
206 20.01 63A Isolator with SS Enclosure item186 5 Nos
207 20.02 100A Isolator with SS Enclosure item187 5 Nos
208 20.03 125A Isolator with SS Enclosure item188 2 Nos
209 21 MCB DISTRIBUTION BOARDS:- SITC of following distribution boards. :- MCCB/MCB distribution boards shall be totally enclosed with double door,vertical,surface/recessed mounting type, shall be hinged type with push in type spring/magnetic lock, inner door shall be fixed up with screws with cutouts for MCB operation,copper busbar of at least 1.5 times the rating of incomer MCB/MCCB. The DB shall be completely wired up, up to incoming and outgoing terminals by PVC insulated flexible copper wire of adequate rating. All ELCB installed in LDB & PDB shall be rated for 30mA & 100mA leakage current respectively . All MCB in pwer DB shall be suitable for motive power (curve C ).
210 21.01 16 WAY TPN MCCB VDB. item189 8 Nos
211 21.02 14 WAY TPN MCCB VDB. item190 2 Nos
212 21.03 12 WAY TPN MCCB VDB. item191 2 Nos
213 21.04 8 WAY TPN MCCB VDB. item192 4 Nos
214 21.05 6 WAY TPN MCCB VDB. item193 1 Nos
215 21.06 12 WAY TPN VDB. item194 2 Nos
216 21.07 6 WAY TPN VDB. item195 2 Nos
217 21.08 4 WAY TPN VDB. item196 1 Nos
218 21.09 12 WAY SPN DB. item197 3 Nos
219 21.1 8 WAY TPN DB. item198 10 Nos
220 21.11 4 WAY TPN DB. item199 4 Nos
221 21.12 100A, 4P MCCB Thermal rels item200 2 Nos
222 21.13 80A, 4P MCCB Thermal rels item201 1 Nos
223 21.14 63A, 4P MCCB Thermal rels item202 6 Nos
224 21.15 40A, 4P MCCB Thermal rels item203 1 Nos
225 21.16 32A, 4P MCCB Thermal rels item204 2 Nos
226 21.17 63A, 4P MCB item205 1 Nos
227 21.18 40A, 4P MCB item206 1 Nos
228 21.19 32A, 4P MCB item207 14 Nos
229 21.2 63A, TP MCB item208 1 Nos
230 21.21 50A, TP MCB item209 1 Nos
231 21.22 40A, TP MCB item210 1 Nos
232 21.23 6/10/16/20A,25A /32A, TP MCB item211 52 Nos
233 21.24 20A, DP MCB item212 2 Nos
234 21.25 6/32A SP MCBS item213 350 Nos
235 21.26 40A, 4P, 30mA ELCB item214 4 Nos
236 21.27 32A, 4P, 30mA ELCB item215 6 Nos
237 21.28 63A, 4P, 100mA ELCB item216 2 Nos
238 21.29 40A, 4P, 100mA ELCB item217 2 Nos
239 22 SITC STREET LIGHTING DB(IP-65):- DB Should have a provision for incoming cable of size 4CX16 Sq.mm XLPE AL. cable & 8 runs of 4CX4Sq.mm outgoing cables from Bottom & having 24 Hour Digital Timer unit with Auto/Manual Control. The cost for this item shall also include the Metalic/PCC pedestal, RCC foundation below ground and all other mounting/fixing accessories complete as required.
240 22.01 65W -Street Light with pole and all accessories like contractor , MCB , timer etc. item218 52 Nos
241 23 UPS/ INVERTERS/ISOLATORS WITH ENCLOUSER, MCCB WITH ENCLOUSER
242 23.01 40 KVA UPS :- Supply, Installation,testing and commissioning of 440volt, 50 hz, 3phase AC input and output of 3 phase, 415volt, 50 hz. Supply should include batteries of UPS for 30 Minutes back up. The Installation shall be as per standard & specifications and manufacturer's manual and relavant codes and standards. BATTERIES : PANASONIC/ROCKET KOREA, 30 min backup- WITH RACK CAPACITY I/P ISOLATION TRANSFORMER AND SNMP & MODUBUS OPTIONS item219 1 Nos
243 24 5KVA INVERTER:- Supply, Installation,testing and commissioning of 1 phase Inverter - 230volt, 50 hz, AC input and output 230volt AC , 50 hz, sine wave ; 60 mins. Back-up with maintenance free battery. The Installation shall be as per standard RRL specifications and manufacturer's manual and relavant codes and standards. Make - Luminous/Microtek/Sukam 5 kVA. item220 1 Nos
244 25 ENCLOSURES
245 25.01 63A FP, MCB with ENCLOUSRE item221 3 Nos
246 26 CABLES/END TERMINATIONS - POWER AND CONTROL ARMOURED CABLES: The LT cable will be 1.1KV grade, XLPE insulated, FR PVC outer sheathed; GI wire/strip armoured having stranded Aluminium/ Copper conductor. Cables will be as per IS: 7098 Part I / II . Supply and Laying of XLPE Insulated FR PVC outer sheathed, inner extruded PVC sheath, 3/3.5 / 4 CORE, ARMOURED, stranded ALUMINIUM /COPPER conductor cables of 1.1KV ' class cables as per IS.
247 26.01 3.5C x 400 Sq.mm. Al XLPE item222 500 Mtr
248 26.02 3.5C x 300 Sq.mm. Al XLPE item223 250 Mtr
249 26.03 3.5C x 240 Sq.mm. Al XLPE item224 200 Mtr
250 26.04 3.5C x 185 Sq.mm. Al XLPE item225 150 Mtr
251 26.05 3.5C x 150 Sq.mm. Al XLPE item226 60 Mtr
252 26.06 3.5C x 120 Sq.mm. Al XLPE item227 100 Mtr
253 26.07 3.5C x 95 Sq.mm. Al XLPE item228 150 Mtr
254 26.08 3.5C x 70 Sq.mm. Al XLPE item229 100 Mtr
255 26.09 3.5C x 50 Sq.mm. Al XLPE item230 100 Mtr
256 26.1 3.5C x 35 Sq.mm. Al XLPE item231 60 Mtr
257 26.11 4C x 25 Sq.mm. Al XLPE item232 400 Mtr
258 26.12 4C x 16 Sq.mm. Al XLPE item233 500 Mtr
259 26.13 4C x 10 Sq.mm. Alu XLPE item234 500 Mtr
260 26.14 4C x 6 Sq.mm. Alu XLPE item235 200 Mtr
261 26.15 4C x 4 Sq.mm. Alu XLPE item236 250 Mtr
262 26.16 3C x 16 Sq.mm. Alu XLPE item237 200 Mtr
263 26.17 3C x 6 Sq.mm. Alu XLPE item238 1000 Mtr
264 26.18 3C x 4 Sq.mm. Alu XLPE item239 1000 Mtr
265 26.19 2C x 2.5 Sq.mm Cu XLPE item240 200 Mtr
266 26.2 4C x 2.5 Sq.mm Cu XLPE item241 100 Mtr
267 26.21 3C x 1.5 Sq.mm Cu XLPE item242 200 Mtr
268 26.22 2C x 2.5 Sq.mm Cu XLPE item243 200 Mtr
269 26.23 2C x 1.5 Sq.mm Cu XLPE item244 100 Mtr
270 27 Supply and Laying of XLPE Insulated FR PVC outer sheathed, inner extruded PVC sheath,UNARMOURED, stranded COPPER conductor cables of 1.1KV ' class cables per IS 7098 part - 1. The cable shall either be ' laid in trench 0.5Mwide 0.75M deep / RCC ' Hume pipe of size 150mm / ready - made cable tray with proper clamping. Rate shall be inclusive of cable tags, clamps, etc. Cable tag shall be of aluminium engraved sheets(2mm) tied at regular intervals of not less than 10 mtrs.
271 27.01 1C x 70 Sq.mm Cu XLPE item245 30 Mtr
272 27.02 1C x 16 Sq.mm Cu XLPE item246 70 Mtr
273 27.03 1C x 10 Sq.mm Cu XLPE item247 50 Mtr
274 27.04 1C x 6 Sq.mm Cu XLPE item248 50 Mtr
275 27.05 4C x 50 Sq.mm Cu XLPE item249 50 Mtr
276 27.06 4C x 70 Sq.mm Cu XLPE item250 100 Mtr
277 28 CABLE END TERMINATIONS:- Supply and making END TERMINARION with brass single compression glands for indoor terminations & solderless crimping type tinned Cu lugs for the following XLPE insulated PVC sheathed 1100 V grade, ARMOURED, stranded, ALUMINIUM/COPPER conductor cable including cost of ferrules, cable sockets, insulation tape and other accessories as required. Make - Dowells/Comet
278 28.01 3.5C x 400 Sq.mm. Al XLPE item251 30 Nos
279 28.02 3.5C x 300 Sq.mm. Al XLPE item252 12 Nos
280 28.03 3.5C x 240 Sq.mm. Al XLPE item253 12 Nos
281 28.04 3.5C x 185 Sq.mm. Al XLPE item254 16 Nos
282 28.05 3.5C x 150 Sq.mm. Al XLPE item255 10 Nos
283 28.06 3.5C x 120 Sq.mm. Al XLPE item256 8 Nos
284 28.07 3.5C x 95 Sq.mm. Al XLPE item257 10 Nos
285 28.08 3.5C x 70 Sq.mm. Al XLPE item258 8 Nos
286 28.09 3.5C x 50 Sq.mm. Al XLPE item259 12 Nos
287 28.1 3.5C x 35 Sq.mm. Al XLPE item260 4 Nos
288 28.11 4C x 25 Sq.mm. Al XLPE item261 20 Nos
289 28.12 4C x 16 Sq.mm. Al XLPE item262 22 Nos
290 28.13 4C x 10 Sq.mm. Alu XLPE item263 30 Nos
291 28.14 4C x 6 Sq.mm. Alu XLPE item264 12 Nos
292 28.15 4C x 4 Sq.mm. Alu XLPE item265 10 Nos
293 28.16 3C x 16 Sq.mm. Alu XLPE item266 4 Nos
294 28.17 3C x 6 Sq.mm. Alu XLPE item267 4 Nos
295 28.18 3C x 4 Sq.mm. Alu XLPE item268 20 Nos
296 28.19 2C x 2.5 Sq.mm Cu XLPE item269 4 Nos
297 28.2 4C x 2.5 Sq.mm Cu XLPE item270 6 Nos
298 28.21 3C x 1.5 Sq.mm Cu XLPE item271 4 Nos
299 28.22 2C x 2.5 Sq.mm Cu XLPE item272 8 Nos
300 28.23 2C x 1.5 Sq.mm Cu XLPE item273 10 Nos
301 28.24 1C x 70 Sq.mm Cu XLPE item274 6 Nos
302 28.25 1C x 16 Sq.mm Cu XLPE item275 10 Nos
303 28.26 1C x 10 Sq.mm Cu XLPE item276 10 Nos
304 28.27 1C x 6 Sq.mm Cu XLPE item277 12 Nos
305 28.28 4C x 50 Sq.mm Cu XLPE item278 4 Nos
306 28.29 4C x 70 Sq.mm Cu XLPE item279 4 Nos
307 29 From DB'S to Equipment including termination
308 29.01 1.5 MM² , 3 run Copper Flexible wire (For Light ) item280 9000 Mtr
309 29.02 2.5 MM² , 3 run Copper Flexible wire (For power socket ) item281 2000 Mtr
310 29.03 4 MM² , 3 run Copper Flexible wire (For MCS ) item282 500 Mtr
311 29.04 4 MM² , 5 run Copper Flexible wire (For 3 PH MCS ) item283 150 Mtr
312 30 PVC CONDUIT PIPES
313 30.01 20mm medium duty PVC Pipe item284 1500 Mtr
314 30.02 25mm medium duty PVC Pipe item285 2000 Mtr
315 30.03 20mm Junction Box item286 500 Mtr
316 30.04 25mm Junction Box item287 500 Mtr
317 31 FLEXIBLE PVC PIPES
318 31.01 20mm item288 500 Mtr
319 31.02 25mm item289 250 Mtr
320 31.03 32mm item290 200 Mtr
321 32 SWITCH BOARD (MODULAR):- SITC of following size of Concealed Boxes.
322 32.01 Two Module Box item291 50 Nos
323 32.02 Three Module Box item292 30 Nos
324 32.03 Four Module Box item293 40 Nos
325 32.04 Six Module Box item294 20 Nos
326 32.05 Eight Module Box item295 20 Nos
327 32.06 Twelve Module Box item296 5 Nos
328 32.07 Sixteen Module Box item297 6 Nos
329 33 SITC of following size of PVC Surface Boxes.
330 33.01 Two Module Box item298 6 Nos
331 33.02 Three Module Box item299 3 Nos
332 33.03 Four Module Box item300 6 Nos
333 33.04 Six Module Box item301 6 Nos
334 33.05 Eight Module Box item302 10 Nos
335 34 SITC of following size of SS plates.
336 34.01 One Module Plate item303 20 Nos
337 34.02 Two Module Plate item304 30 Nos
338 34.03 Three Module Plate item305 30 Nos
339 34.04 Four Module Plate item306 40 Nos
340 34.05 Six Module Plate item307 20 Nos
341 34.06 Eight Module Plate item308 20 Nos
342 34.07 Twelve Module Plate item309 5 Nos
343 34.08 Sixteen Module Plate item310 6 Nos
344 35 SITC of following Modular Accessories.
345 35.01 One way Switch 6A item311 250 Nos
346 35.02 Two way Switch 6A item312 16 Nos
347 35.03 One way Switch 16A item313 30 Nos
348 35.04 6A, 3 pin socket item314 50 Nos
349 35.05 16A, 3 pin socket item315 30 Nos
350 35.06 16A, 3 pin socket outlet with 20A DP Switch item316 10 Nos
351 35.07 32A, TPN socket outlet with 32A FP MCB in metal enclosure item317 20 Nos
352 35.08 20A, 3 pin socket outlet with 20A DP MCB in metal enclosure item318 25 Nos
353 35.09 Switch Dummy item319 50 Nos
354 36 G.I LADDER & PERFORATED TYPE CABLE TRAYS/ FLOOR TRUNKING FOR VOICE , DATA & POWER OUTLETS: Supply, Installation , testing and commissioning of Hot Dip Galvanised perforated cable tray, G.I, 1.6mm thick for Electrical Cable with G.I Angle/Hitech Threaded rods with Anchor fasteners, Clamps, bolts,nuts including all the necessary fasteners as per RRL std specs
355 36.01 50 x50 mm item320 500 Mtr
356 36.02 100 x 50 mm item321 200 Mtr
357 36.03 150 x 50 mm item322 100 Mtr
358 36.04 300 x 50 mm item323 500 Mtr
359 36.05 450 x 50 mm item324 400 Mtr
360 36.06 600 x 100 mm item325 200 Mtr
361 37 Supply, Installation , testing and commissioning of Hot Dip Galvanised Ladder type MS painted cable tray with all accessories including anchor fasteners, couplers & fixing structures, as per RRL std specs G.I, 1.6mm thick for Electrical Cable with G.I Angle/Hitech Threaded rods with Anchor fasteners, Clamps, bolts,nuts including all the necessary fasteners as per RRL std specs
362 37.01 300 x 100 mm item326 150 Mtr
363 37.02 450 x 100 mm item327 125 Mtr
364 37.03 600 x 100 mm item328 100 Mtr
365 37.04 750 x 100 mm item329 150 Mtr
366 37.05 1000 x 100 mm item330 100 Mtr
367 38 STRUCTURAL STEEL
368 38.01 Supply and fabrication of various sizes of angles/brackets/channels/frames, etc of Structural steel with one coat of red oxide & two coat of enamel approved paint for supporting equipment/cables, etc item331 2500 Kg
369 39 POWER RECEPTACLES:- Supply ,Installation, testing and commissioning of Plug and socket DB's with suitable MCBs and neutral links housed in Stainless steel enclosure,dulywired, with earthing facility. The rate shall include switch plates, chasing walls/floors fine finished plastering with wire mesh etc.
370 39.01 10A, 3pin socket with 10A SP MCB item332 11 Nos
371 39.02 10A, 3pin socket 2 Nos. with 10A SP MCB individual control item333 51 Nos
372 39.03 25A,3 Phase power socket 2 Nos. with 25A TPN MCB individual control item334 9 Nos
373 39.04 10A,3pin socket with 10A SP MCB and 25A,3 Phase power socket with 25A TPN MCB item335 15 Nos
374 39.05 32A,3 Phase power socket with 32 TPN MCB item336 11 Nos
375 39.06 ON / OFF Push Button for AHU Starters item337 50 Nos
376 39.07 25A FP MCB item338 4 Nos
377 39.08 32A FP MCB item339 5 Nos
378 39.09 40A FP MCB item340 3 Nos
379 40 SUPPLY & INSTALATION OF INTERNAL CLEAN ROOM LIGHT FIXTURES WITH REQUIRED ACCESSORIES- CLEAN ROOM FITTINGS-FLAME PROOF
380 40.01 22W, 300 X 300MM LED SQUARE item341 139 Nos
381 40.02 36W, 600 X 600MM LED SQUARE item342 126 Nos
382 41 NON - FLAME PROOF
383 41.01 22W, 300 X 300MM LED SQUARE item343 400 Nos
384 41.02 36W, 600 X 600MM LED SQUARE item344 606 Nos
385 42 INDUSTRIAL LIGHT FITTINGS
386 42.01 10W PL Light item345 22 Nos
387 42.02 1x40W Industrial Tube Fittings item346 46 Nos
388 42.03 2x40W Industrial Tube Fittings item347 157 Nos
389 43 FLAME PROOF - INDUSTRIAL LIGHT FITTINGS
390 43.01 1x40W Industrial Tube Fittings item348 46 Nos
391 44 EXTERNAL LIGHIT FIXTURES WITH REQUIRED ACCESSORIES:-Supply ,Installation & commissioning of following of prewired light fittings/ light tracks, complete The fitting shall be fixed with chain ,screws etc. & recessed mounted in false ceiling. Cost of chains Screws to be considered in these items. All fittings to be IP 65 certified.
392 44.01 24W LED LIGHT COLUMN item349 8 Nos
393 44.02 24W LED BOLLARD -Make : Klite/Wipro/Philips/Havels/ Bajaj item350 5 Nos
394 44.03 20W LED PILLAR LUMINAIRIES-Pillar light with Cluster of LED lamps complete with Drivers & all required accessories- Make : Klite/Wipro/Philips/Havels/ Bajaj item351 3 Nos
395 45 Emergency Luminaire :- Light in each floor should be connected from UPS.
396 45.01 22W ( Size - 300mm X 300mm ) item352 75 Nos
397 45.02 36W ( Size - 600mm X 600mm ) item353 30 Nos
398 45.03 2 X 40W Industrial fitting light item354 20 Nos
399 46 EXHAUST FANS:-SITC of exhaust fans with sheet metal blades of following sizes of white colour or architects/clients approved colour, Exhaust fans with necessary brackets anti corresive epoxy painting, ruber cushion accessories, connecting wire & other standard accessories complete as required. The scope of works includes minor civil work.
400 46.01 Supply & Installation of 225 mm dia, 900 rpm single phase exhaust fan item355 5 Nos
401 46.02 450 mm impeller dia, 1400 rpm exhaust fan item356 2 Nos
402 47 CEILING FANS:
403 47.01 75 watts ceiling fan - 48\" DIA item357 3 Nos
404 47.02 Fan Regulator item358 3 Nos
405 48 EARTHING SYSTEMS-EARTHING STATIONS:
406 48.01 Supply, providing, Installing, testing & commissioning of copper plate earthing station using 600x600x3mm Cu plate including excavation, backfilling, construction of inspection chamber, chamber cover (CI), disconnecting link etc.,as per IS-3043/spec. (UPS DEDICATED EARTHING & DG NEUTRAL) item359 4 Nos
407 48.02 Supply and Installation of earthing station as per IS standard complete with 1200 x 1200 x 12 mm C.I. plate earthing electrode plate, charcoal, 2 nos. 50 x6 mm G.I Conductor upto test link, 32 mm dia G.I watering pipe with funel,test link. The earthing chamber size shall be 450x450 mm with C.I Manhole chamber etc. as per drawing. The identification number shall be provided both inside and outside of equipment. (ALL PANEL & EQUIPMENT EARTH) item360 10 Nos
408 48.03 Supply and providing Pipe earthing as per IS 3043 with 3 Metre long 40 mm dia. 'B' class G.I pipe, with necessary accessories, including 300x300mm Cast iron Frame covering at the top. item361 4 Nos
409 49 EARTHING STRIPs/WIREs:- Supply and laying earth strips 0.5M below ground/exposed including connections by proper nut-bolts/welding.
410 49.01 75 x 6 mm. G.I strip. item362 200 Mtr
411 49.02 50 x 6 mm. G.I strip. item363 1500 Mtr
412 49.03 50 x 6 mm Cu. strip item364 500 Mtr
413 49.04 32 x 6 mm G.I strip item365 50 Mtr
414 49.05 25 x 6 mm G.I strip item366 500 Mtr
415 49.06 25 x 6 mm Cu. strip item367 200 Mtr
416 49.07 25 x 3 mm G.I strip item368 50 Mtr
417 49.08 25 x 3 mm Cu. Strip item369 150 Mtr
418 49.09 10 SWG Cu. wire item370 3000 Mtr
419 49.1 6 SWG Cu. wire item371 500 Mtr
420 50 Earth Bench:- Supply and clamping 30cm tinned Cu. Earth bench of the following sizes on the surface of wall for connecting earth continuity leads at required locations.
421 50.01 25 x 3 mm item372 10 Nos
422 50.02 25 x 6 mm item373 6 Nos
423 51 LIGHTNING PROTECTION SYSTEM ( BUILDING LIGHTENING ARRESTOR)
424 51.01 Supply, Installation, Testing & Commissioning of Advanced Lightening Protection System- Controlled Streamer Emmision (CSE) Technology complete with all accessories. item374 3 Set
425 52 Safety items:- Safety Equipments: Supply, Installation of below mention safety equipment including all labour and materials etc., complete as per directions of Engineer-In-Charge.
426 52.01 Fire buckets with stand-2 buckets. Bucket of round bottom, painted red, marked 'FIRE' & duly filled with river sand. item375 3 Set
427 52.02 Best quality LT Danger Boards for of approved shape and size as specified by the local electrical authorites written in English, hindi and local language item376 5 Nos
428 52.03 Best quality HT Danger Boards for of approved shape and size as specified by the local electrical authorites written in English, hindi and local language item377 2 Nos
429 52.04 Rubber mat suitable for operating voltage upto 1.1 KV item378 8 Nos
430 52.05 Rubber mat suitable for operating voltage upto 11 KV item379 2 Nos
431 52.06 Hand Gloves suitable for operating voltage upto 11 KV item380 2 Pair
432 52.07 Approved shock treatment chart written in English, Hindi and in local language. item381 2 Nos
433 52.08 First Aid Box item382 2 Nos
434 52.09 DCP fire extingusher 4.5 kg item383 6 Nos
435 53 APPENDIX B Electrical Control Panels and Cabling - HVAC Equipments Electrical panel consisting of main incomming starter (MCCB),metering section consisting of digitial voltmeter,ammeter and out going feeder for ahus, and Panel shall be totally enclosed ,completely dust proof, with hinged doors ,neoprene gasket and suitable locking arrangement. and push buttons,lamps,emergency stop switch , switch gears and AHU door indication etc. MCCB PANELS FOR AHUS,DEHUMIDIFIERS,HETERS,
436 53.01 PANNEL - I ( GROUND FLOOR) item384 1 Nos
437 53.02 PANNEL - II ( FIRST FLOOR) item385 1 Nos
438 53.03 PANNEL - III (SECOND & SERVICE FLOOR) item386 1 Nos
439 53.04 PANNEL - IV ( CHILLERS ,COOLING TOWER, PUMPS)] item387 1 Nos
440 54 Electrical Control Panels and Cabling - HVAC Equipments Electrical panel consisting of main incomming starter (MCCB),metering section consisting of digitial voltmeter,ammeter and out going feeder for ahus, and Panel shall be totally enclosed ,completely dust proof, with hinged doors ,neoprene gasket and suitable locking arrangement. and push buttons,lamps,emergency stop switch , switch gears and AHU door indication etc & consider VFD load with AHU panels. MCCB PANELS FOR AHUS,DEHUMIDIFIERS,HETERS,
441 54.01 PANNEL - I ( GROUND FLOOR) item388 1 Nos
442 54.02 PANNEL - II ( FIRST FLOOR) item389 1 Nos
443 54.03 PANNEL - III (SECOND & SERVICE FLOOR) item390 1 Nos
444 55 POWER CABLING & CONTROL CABLING -Armoured power cables.
445 55.01 3C X 1.5 SQMM CU item391 1100 Rmt
446 55.02 3C X 2.5 SQMM CU item392 440 Rmt
447 55.03 3C X 10 SQMM AL item393 150 Rmt
448 55.04 4C X 1.5 SQMM CU item394 310 Rmt
449 55.05 4C X 2.5 SQMM CU item395 150 Rmt
450 55.06 4C X 4 SQMM CU item396 440 Rmt
451 55.07 4C X 6 SQMM AL item397 110 Rmt
452 55.08 4C X 10 SQMM AL item398 150 Rmt
453 55.09 4C X 16 SQMM AL item399 310 Rmt
454 55.1 4C X 25 SQMM AL item400 310 Rmt
455 55.11 4C X 50 SQMM AL item401 220 Rmt
456 55.12 4C X 300 SQMM AL item402 160 Rmt
457 56 CONTROL CABLING:- Control Cabling from field devices to starter panels of AHU's to all individual motors .
458 56.01 4 C X 1.5 SQ.MM. item403 2500 Rmt
459 57 DOUBLE COMPRESSION GLANDS
460 57.01 20 MM item404 168 Nos
461 57.02 25 MM item405 72 Nos
462 57.03 32 MM item406 8 Nos
463 57.04 50 MM item407 8 Nos
464 58 END TERMINALS
465 58.01 3C X 1.5 SQMM CU item408 240 Nos
466 58.02 3C X 2.5 SQMM CU item409 88 Nos
467 58.03 3C X 10 SQMM AL item410 8 Nos
468 58.04 4C X 1.5 SQMM CU item411 88 Nos
469 58.05 4C X 2.5 SQMM CU item412 38 Nos
470 58.06 4C X 4 SQMM CU item413 185 Nos
471 58.07 4C X 6 SQMM AL item414 26 Nos
472 58.08 4C X 10 SQMM AL item415 38 Nos
473 58.09 4C X 16 SQMM AL item416 88 Nos
474 58.1 4C X 25 SQMM AL item417 76 Nos
475 58.11 4C X 50 SQMM AL item418 38 Nos
476 58.12 4C X 300 SQMM AL item419 26 Nos
477 59 GI PERFORATED TYPE CABLE TRAY:- Factory fabricated GI perforated type cable tray made out of 14swg sheet steel. supporting angle frame at every 1.2 m, bottom angles, anchor fasteners, bolts and nuts etc. The tray shall be suspended from ceiling using anchor bolt and angle iron supports or threaded rods. The rate shall include all accessories like bends, elbows, tees, coupler plates, joints and fixing accessories etc., which will be measured as linear measurement.
478 59.01 200 MM X 50 MM item420 550 Rmt
479 59.02 250 MM X 50 MM item421 550 Rmt
480 59.03 300 MM X 50 MM item422 550 Rmt
481 59.04 450 MM X 50 MM item423 425 Rmt
482 60 EARTHING
483 60.01 25 X 3 MM GI Earth Strip item424 725 Rmt
484 60.02 25 X 6 MM GI Earth Strip item425 425 Rmt
485 60.03 4 SQMM Copper wire item426 1450 Rmt
486 61 APPROVAL AND SANCTION
487 61.01 Professional charges for preparation of drawings, getting approval from the Electrical Inspectorate, submission of completion report , follow up action for getting sanction for energisation , complying all formalities with Electrical Inspectorate for getting power connection. All expenses in excluding statutory charges. Statutory charges shall be paid by the client. item427 1 Lot
488 61.02 Professional charges of preparation of documents, submission of completion report , follow up actions for getting power connection from KSEB, complying all formalities. All expenses excluding statutory charges. Statutory charges shall be paid by the client. item428 1 Lot
489 62 P.N. QUANTITY & SPECIFICATIONS MAY VARY AS PER FINAL DESIGN , SITE CONDITION . ANY REQUIRED ITEMS AS PER SITE CONDITION TO BE CONSIDERED.( WHICH IS NOT INCLUDED IN THIS LIST.)

AI Tender Summary

OUR REF NO 21165267
AUTHORITY Cooperative
TENDER VALUE 4.20 Crore
LAST DATE 14-08-2019
Authority
Authority Name Kerala State Homoeopathic Co-Operative Pharmacy Limited
Work Description Construction Of Modern Factory Cum Lab For Homco At Valiyakalavoor , Alappuzha-Electrical Works As Per Cgmp Norms
Basic Detail
Tender No HOMCO/T-04/2019-20
Bidding Type Tender
Location
City HOMCO, Valiya Kalavoor, Alappuzha, Kerala
State Kerala
Key Dates
Publish Date 25 Jul 2019
Submission Date 14 Aug 2019
Open Date 19 Aug 2019
Finance
Tender Value 4.20 Crore
Tender Fee 8400
EMD 1 Lakhs
Exemption Not Available
Document List
11CA4299-2800-41FA-8837-54B808178533.html
BOQ_393484.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 25, 2019
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 14, 2019
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Aug 19, 2019

Bid Opening Date

Technical bids will be opened and evaluated.