Provision Of Web Based Energy Meters At Tb , Cargo Complex And Residential Colony At Chennai Airport . Sh Provision Of Smart Meters Advanced Metering Infrastructure ( Ami ) In Terminal Buildings . , Chennai Airport-Tamil Nadu

Airports Authority Of India has published Provision Of Web Based Energy Meters At Tb , Cargo Complex And Residential Colony At Chennai Airport . Sh Provision Of Smart Meters Advanced Metering Infrastructure ( Ami ) In Terminal Buildings . . Submission Date for this Tender is 14-08-2019. Energy Meter Tenders in Chennai Airport Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

21160151
Provision Of Web Based Energy Meters At Tb , Cargo Complex And Residential Colony At Chennai Airport . Sh Provision Of Smart Meters Advanced Metering Infrastructure ( Ami ) In Terminal Buildings .
Open Tender
Indian
Tamil Nadu
Chennai Airport
14-08-2019

Tender Details

Provision Of Web Based Energy Meters At Tb , Cargo Complex And Residential Colony At Chennai Airport . Sh Provision Of Smart Meters Advanced Metering Infrastructure ( Ami ) In Terminal Buildings .

Key Value

Document Fees
INR 1120 /-
EMD
INR 265000.0 /-
Tender Value
INR 1.32 Crore /-

BOQ Items

Sl. No. Item Description Item Code / Preferred Make Quantity Unit
1 1 PART-I: SITC of Smart Meters/ AMI System
2 1.01 Supply, Installation, Testing & Commisioning of AC Single phase Two wire, Tamper proof, static energy meter of class 1.0 accuracy, 240V, 50Hz, 05-30A confirming to IS - 16444 and relevant IEC standards with inbuilt RF communication facility which support Mesh network with near by existing meters, display all basic parameters , anti-tamper features, Password protection, interconnections, Earthing, dismantling of existing meter and hand over to AAI Store, complete as required. 198 Nos
3 1.02 Supply, Installation, Testing & Commisioning of AC Three phase four wire, Tamper proof, static energy meter of class 1.0 accuracy, 440V, 50Hz, 10-60A confirming to IS - 16444 and relevant IEC standards with inbuilt RFcommunication facility which support Mesh network with near by existing meters, display all basic parameters, anti-tamper features, Password protection, interconnections, Earthing, dismantling of existing meter and hand over to AAI Store, complete as required. 96 Nos
4 1.03 Supply, Installation, Testing & Commisioning of AC Single phase Two wire, Tamper proof, static energy meter of class 1.0 accuracy, 240V, 50Hz, 05-30A confirming to IS - 16444 and relevant IEC standards with inbuilt RF communication facility with Data Concentrator Unit with Wi-fi/LAN to transfer direct data into server and display all basic parameters , anti-tamper features, Password protection, interconnections, Earthing, required open source DCU software, programming etc. complete as required. dismantling of existing meter and hand over to AAI Store, complete as required. 88 Nos
5 1.04 Supply, Installation, Testing & Commisioning of AC Three phase four wire, Tamper proof, static energy meter of class 1.0 accuracy, 440V, 50Hz, 10-60A confirming to IS - 16444 and relevant IEC standards with inbuilt RF communication facility with Data Concentrator Unit with Wi-fi/LAN to transfer direct data into server and display all basic parameters, anti-tamper features, Password protection, interconnections, Earthing,required open source DCU software, programming etc.. dismantling of existing meter and hand over to AAI Store, complete as required. 39 Nos
6 1.05 Supply, Installation, Testing & Commisioning of AC CT Operated Three phase four wire, Tamper proof, static energy meter of class0.5s accuracy, 440V, 50Hz, 5Amps confirming to IS - 16444 and relevant IEC standards with inbuilt RF communication facility which support Mesh network with default in the existing Distribution Board and anti-tamper features, Microprocessor and LED/LCD based circuitry, including suitable rating of CTs, interconnections, Connections, Earthing, . complete as required. etc. complete as required. 37 Nos
7 1.06 Supply, Installation, Testing & Commisioning of Repeater in wireless for data transmission alongwith mounting arrangements etc complete as required. 40 Nos
8 1.07 Supply, Installation, Testing & Commisioning of Data concentrator Units (DCUs) in the New Distribution Board for collecting data from all the meters located in Terminal Building, compatible for remote Automatic Meter Reading (AMR) solution and capable of communicating with RF energy Meter with inbuilt RF communication facility which support Mesh network and DCUs shall communicate with data server through Wi-fi/LAN and shall have minimum data transfer of 9600 bps and Data should be retained in DCU if communication not established with server, internal memory to store billing data of connected modules for 6 Month period , provision to view data by conneting external device etc., required open source DCU software, programming suitable to fetch the data from the meter in round robin basis or from each meter etc. complete as required. 20 Nos
9 1.08 Design, supply and Configuring server Hosted multi user Web-based Software with following modules suitable for static IP Address:
10 1.09 Meter Data Management MODULE:- The Meter Data management module shall be responsible for collecting the data from the concentrator and make the data available to the billing system. The system shall support Offline meter data entry. The meter data management system shall capture and provide the following data.
11 1.1 30 Min instantaneous data from all the meters for seven parameters - Cumulative Energy, Cummulative Apparent Energy, Power, Current, Voltage, Power Factor and Frequency.
12 1.11 Monthly and Quarterly billing survey data for cumulative energy and maximum demand and graphical represent.
13 1.12 Billing Module: The billing module shall collect the data from the meter data management module, calculate the energy consumption, calculate billing determinant and energy data / billing data available to admin and end users.
14 1.13 Occupation and Vacation Module:- The system shall support the occupation and vacation events by the Administrator.
15 1.14 Customer Portal: The system shall include a customer portal for the resident / occupant to log in and view their own energy / billing data.
16 1.15 Energy Accounting module: The system shall include features of energy accounting. The system shall be able to account for total energy blockwise, facility wise and shall also allow calculations of un accounted energy in case total energy meter is also available.
17 1.16 Communication Module: The system shall provide communication of energy data and bills via print, email and SMS methods.
18 1.17 Meter Master Data: The system shall support meter master data respiratory.
19 1.18 Total of all above 1.08 to 1.18 1 Job
20 1.19 Supply and installing the Entry level Server with LINUX OS and confitued with static IP Address, montoir with 22 inch monitor etc. complete as required. 1 Job
21 1.2 Wiring for light point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular 5 A switch and Socket, modular plate, suitable Gl box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. 160 Point
22 2 PART-II: ACMC of Smart Meters/ AMI System
23 2.01 All Inclusive Comprehensive Maintenance Contract including software upgrading, software hosting, hardware replacement and resolving any issue pertaining to the system installed along with the following.
24 2.02 The successful bidder shall solely be responsible for replacement of faulty Static Energy Meter, Data Concentrator Unit (DCU), Repeater and any other components which are installed by the Agency.
25 2.03 The contractor shall provide a dedicated phone number and email address to which the Engineer-in-charge will be able to provide the complaint for non-functioning of any system component.
26 2.04 Any defect and any interruption noticed shall be got rectified within 24 hours from notification. An amount of Rs.50/- per day per meter shall be recovered after that period if the defect and interruption noticed has not been rectified.
27 2.05 The rate quoted by the contractor shall be inclusive of above points (2.01) to (2.04 ) and nothing shall be paid extra.
28 2.06 For First Year after expiry of Defects liability period 12 Months
29 2.07 For Second Year after expiry of Defects liability period 12 Months
30 2.08 For Third Year after expiry of Defects liability period 12 Months
31 2.09 For Fourth Year after expiry of Defects liability period 12 Months
32 2.1 For Fifth Year after expiry of Defects liability period 12 Months
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail