Tender For Under Maintenance Of Parishad Head Quarter , Providing , Installation , Testing And Commissionig Of Multi V ( Iv Gen . ) Vrf Air Conditioning Of Lg Make Modular System In Meeting Hall ( Naveen Bhavan ) In Place Of Old Air Conditioning S
Tender Overview
Project Description
Tender For Under Maintenance Of Parishad Head Quarter , Providing , Installation , Testing And Commissionig Of Multi V ( Iv Gen . ) Vrf Air Conditioning Of Lg Make Modular System In Meeting Hall ( Naveen Bhavan ) In Place Of Old Air Conditioning System At U . P . Avas Evam , Supply Of Lg Make Modular Vrf Multi V ( Iv Gen . ) Outdoor Unit And As Per The Nominal Capacity Mentioned Below . The Vrf Systems Will Have Cooling & Heating Mode ( Heat Pump ) , All Invertor Technology Based Scroll Compressors , Machine Should Having Ocean Black Anticorrosive Coating For Long Life Having Salient Features Suchas Ocean Balck Fins Having Anti Corrosive Coating , Smart Load Controll Operation , Auto Dust Removal , All Invertor Technology Based Scroll Compressors ( Own Manufactured ) , High Ambient Operation I . E . Upto 530C Ambient Temp , High Part Load Efficiency Due To 6 Bypass Valve In Compressor And 15 Hz To 150 Hz Operation . The Refrigerant Shall Be R-410A ( Environment Friendly ) Of Following Capacity:- , Odu - 16 Hp Or 12 . 80 Tr ( Modle No . Jrnu160lls4 ) , Odu - 20 Hp Or 16 . 00 Tr ( Modle No . Jrnu200lls4 ) , Supply Of Lg Make Indoor Unit With Electronic Expansion Valve Following Capacity . , Cassette Type Unit - 2 . 0 Tr ( Modle No . Jrnu24gtpa4 ) , Cassette Type Unit - 3 . 0 Tr ( Modle No . Jrnu36gtna4 ) , Cassette Type Unit - 4 . 0 Tr ( Modle No . Jrnu48gtma4 ) , Cordless Remote Control ( Modle No . Pqwrhq0fdb / Pqrcvsl0qw1 ) , Y-Joints . , Outdoor Refnet , Installation Part , Installation , Testing & Commissioning Of Multi V ( Iv Gen . ) Variable Refrigerant Flow Modular Type Air- Conditioning System Suitable For Cooling & Heating By Inverter Driven Capacity Control Compressor Complete With Indoor And Outdoor Units With Controllers And Charging Of Refrigerant Gas Outdoor Units . ( Heating And Cooling ) , Odu - 16 Hp Or 12 . 80 Tr ( Modle No . Jrnu160lls4 ) , Odu - 20 Hp Or 16 . 00 Tr ( Modle No . Jrnu200lls4 ) , Installation , Testing & Commissioning Of Indoor Units ( Nominal Capacity ) , Cassette Type Unit - 2 . 0 Tr ( Modle No . Jrnu24gtpa4 ) , Cassette Type Unit - 3 . 0 Tr ( Modle No . Jrnu36gtna4 ) , Cassette Type Unit - 4 . 0 Tr ( Modle No . Jrnu48gtma4 ) , Cassette Panel , Supply And Installation Part , Sitc Of Interconnecting Refrigerant Pipe Work With ( 19Mm / 13 Mmthick ) Closed Cell Elastomeric Nitrile Rubber Tubular Insulation Between Each Set Of Indoor & Outdoor Units As Per Specifications , All Piping Inside The Building Shall Be Properly Supported With Ms Hanger . ( We Have Considered 15 Rmt / Unit ) Copper Pipe ( Outer Diamiter ) Size , 41 . 30 Mm ( 19Mm Thickness Of Insulation ) , 34 . 90 Mm ( 19Mm Thickness Of Insulation ) , 28 . 58 Mm ( 19Mm Thickness Of Insulation ) , 22 . 20 Mm ( 19Mm Thickness Of Insulation ) , 19 . 05 Mm ( 19Mm Thickness Of Insulation ) , 15 . 88 Mm ( 13 Mm Thickness Of Insulation ) , 12 . 70 Mm ( 13 Mm Thickness Of Insulation ) , 9 . 52 Mm ( 13 Mm Thickness Of Insulation ) , Drain Piping Rigid Pvc Piping Complete With Fittings , Supports As Per Specifications And Duly Insulated With 6 Mm Thick Closed Cell Nitrile Rubber Insulation . , 25 Mm , 32 Mm , Control & Transmission Wiring , Providing And Fixing Control Cum Transmission Wiring Of 2 Core X 1 . 5 Sq . Mm Copper Shielded Between Indoors & Outdoor Running Thru Suitable Size Of Pvc Condutes , Slotted Angle Cable Tray For Laying F Pipe And Control Cable , Ms Channal Stand Out Door Units . , Buy- Back Of Old Existing Units , Buy- Back Of Following Capacity Existing Ductable A . C . Which Are In Working Condition But Installed In The Year 2002-2003 ( At Least 16-17 Year Old Installed ) , 16 . 60 Tr . Capacity Ductable A . C . Unit Of Voltas Make . , 6 No . Of 5 Tr . Capacity Ductable A . C . Unit Of L . G . Make , Comprehensive Annual Maintenance Contract , ( Separate Part Of Contract After Warranty Period Of The Work ) Contrector Shall Quote The Rate Of Annual Maintenance Contract After Completion Of Warranty Period I . E 14 Months From Date Of Start Of Work Or 12 Months After Completion Of The Work .
BOQ
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
|---|---|---|---|---|---|
| 1 | 1 | Supply of LG make Modular VRF MULTI V (IV Gen.) outdoor unit and as per the nominal capacity mentioned below. The VRF systems will have cooling & Heating mode (Heat Pump), all invertor technology based scroll compressors, machine should having ocean black anticorrosive coating for long life having Salient Features suchas Ocean Balck Fins Having Anti corrosive Coating, Smart Load Controll Operation, Auto Dust Removal, All invertor technology based scroll compressors (Own Manufactured), High Ambient operation i.e. upto 530C Ambient Temp, High Part Load Efficiency due to 6 Bypass Valve in Compressor and 15 Hz to 150 Hz operation. The refrigerant shall be R-410a (environment friendly) of following capacity:- | BI01010001010000000000000515BI0100001113 | ||
| 2 | 1.1 | ODU - 16 HP or 12.80 TR (Modle No.JRNU160LLS4) | BI01010001010000000000000515BI0100001115 | 2 | Nos |
| 3 | 1.2 | ODU - 20 HP or 16.00 TR (Modle No.JRNU200LLS4) | BI01010001010000000000000515BI0100001115 | 3 | Nos |
| 4 | 2 | Supply of LG make indoor unit with electronic expansion valve following capacity. | BI01010001010000000000000515BI0100001117 | ||
| 5 | 2.1 | CASSETTE TYPE UNIT - 2.0 TR (Modle No. JRNU24GTPA4) | BI01010001010000000000000515BI0100001118 | 4 | Nos |
| 6 | 2.2 | CASSETTE TYPE UNIT - 3.0 TR (Modle No. JRNU36GTNA4) | BI01010001010000000000000515BI0100001119 | 15 | Nos |
| 7 | 2.3 | CASSETTE TYPE UNIT - 4.0 TR (Modle No. JRNU48GTMA4) | BI01010001010000000000000515BI0100001120 | 5 | Nos |
| 8 | 4 | Cordless Remote Control (Modle No. PQWRHQ0FDB / PQRCVSL0QW1) | BI01010001010000000000000515BI0100001121 | 24 | Nos |
| 9 | 5 | Y-JOINTS. | BI01010001010000000000000515BI0100001122 | 22 | Nos |
| 10 | 6 | Outdoor Refnet | BI01010001010000000000000515BI0100001123 | 3 | Nos |
| 11 | 7 | INSTALLATION PART | BI01010001010000000000000515BI0100001126 | ||
| 12 | 8 | Installation, testing & Commissioning of MULTI V (IV Gen.) Variable refrigerant flow modular type air- conditioning system suitable for Cooling & Heating by inverter driven capacity control compressor complete with indoor and outdoor units with controllers and charging of Refrigerant gas Outdoor units. (Heating and Cooling) | BI01010001010000000000000515BI0100001127 | ||
| 13 | 8.1 | ODU - 16 HP or 12.80 TR (Modle No.JRNU160LLS4) | BI01010001010000000000000515BI0100001113 | 2 | Nos |
| 14 | 8.2 | ODU - 20 HP or 16.00 TR (Modle No.JRNU200LLS4) | BI01010001010000000000000515BI0100001114 | 3 | Nos |
| 15 | 9 | Installation, testing & Commissioning of Indoor units (Nominal capacity) | BI01010001010000000000000515BI0100001116 | ||
| 16 | 9.1 | CASSETTE TYPE UNIT - 2.0 TR (Modle No. JRNU24GTPA4) | BI01010001010000000000000515BI0100001117 | 4 | Nos |
| 17 | 9.2 | CASSETTE TYPE UNIT - 3.0 TR (Modle No. JRNU36GTNA4) | BI01010001010000000000000515BI0100001118 | 15 | Nos |
| 18 | 9.3 | CASSETTE TYPE UNIT - 4.0 TR (Modle No. JRNU48GTMA4) | BI01010001010000000000000515BI0100001119 | 5 | Nos |
| 19 | 10 | Cassette Panel | BI01010001010000000000000515BI0100001118 | 24 | Nos |
| 20 | 11 | SUPPLY AND INSTALLATION PART | BI01010001010000000000000515BI0100001120 | ||
| 21 | 12 | SITC of Interconnecting refrigerant pipe work with (19mm/13 mmthick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the building shall be properly supported with MS hanger.(We have considered 15 RMT/Unit ) Copper Pipe (outer diamiter) Size | BI01010001010000000000000515BI0100001121 | ||
| 22 | 12.1 | 41.30 mm ( 19mm Thickness of Insulation) | BI01010001010000000000000515BI0100001125 | 20 | Rmt |
| 23 | 12.2 | 34.90 mm ( 19mm Thickness of Insulation) | BI01010001010000000000000515BI0100001126 | 25 | Rmt |
| 24 | 12.3 | 28.58 mm ( 19mm Thickness of Insulation) | BI01010001010000000000000515BI0100001127 | 70 | Rmt |
| 25 | 12.4 | 22.20 mm( 19mm Thickness of Insulation) | BI01010001010000000000000515BI0100001128 | 40 | Rmt |
| 26 | 12.5 | 19 .05 mm( 19mm Thickness of Insulation) | BI01010001010000000000000515BI0100001113 | 70 | Rmt |
| 27 | 12.6 | 15.88 mm ( 13 mm Thickness of Insulation) | BI01010001010000000000000515BI0100001114 | 175 | Rmt |
| 28 | 12.7 | 12.70 mm ( 13 mm Thickness of Insulation) | BI01010001010000000000000515BI0100001115 | 100 | Rmt |
| 29 | 12.8 | 9.52 mm( 13 mm Thickness of Insulation) | BI01010001010000000000000515BI0100001116 | 215 | Rmt |
| 30 | 13 | Drain Piping Rigid PVC piping complete with fittings, supports as per specifications and duly insulated with 6 mm thick closed cell nitrile rubber insulation. | BI01010001010000000000000515BI0100001118 | ||
| 31 | 13.1 | 25 MM | BI01010001010000000000000515BI0100001119 | 200 | Rmt |
| 32 | 13.2 | 32 MM | BI01010001010000000000000515BI0100001120 | 200 | Rmt |
| 33 | 14 | Control & Transmission Wiring | BI01010001010000000000000515BI0100001122 | ||
| 34 | 15 | Providing and fixing control cum transmission wiring of 2 core X 1.5 sq.mm Copper shielded between indoors & Outdoor running thru suitable size of PVC Condutes | BI01010001010000000000000515BI0100001123 | 800 | Mtr |
| 35 | 16 | Slotted angle cable tray for laying f pipe and control cable | BI01010001010000000000000515BI0100001125 | 300 | Mtr |
| 36 | 17 | MS channal Stand out door units. | BI01010001010000000000000515BI0100001126 | 5 | Nos |
| 37 | 18 | BUY- BACK OF OLD EXISTING UNITS | BI01010001010000000000000515BI0100001128 | ||
| 38 | 19 | Buy- back of following capacity existing ductable A.C. which are in working condition but installed in the year 2002-2003 (at least 16-17 year old installed) | BI01010001010000000000000515BI0100001113 | ||
| 39 | 19.1 | 16.60 TR. Capacity Ductable A.C. Unit of VOLTAS make. | BI01010001010000000000000515BI0100001114 | 2 | Unit |
| 40 | 19.2 | 6 No. Of 5 TR. Capacity Ductable A.C. Unit of L.G. make | BI01010001010000000000000515BI0100001115 | 6 | Unit |
| 41 | 20 | COMPREHENSIVE ANNUAL MAINTENANCE CONTRACT | BI01010001010000000000000515BI0100001117 | ||
| 42 | 21 | (Separate part of contract after warranty period of the work) Contrector Shall quote the rate of Annual Maintenance contract after completion of warranty period i.e 14 months from date of start of work or 12 months after completion of the work. | BI01010001010000000000000515BI0100001118 | 73.6 | TR |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender