Modification of 33KV overhead Danapur feeder 1 & 2 of BSEB on west of canal, 11KV and 415V over head distribution lines along Bailey Road on East of canal through underground cable and shifting of distributionTransformer of BSEB for removal of infringement with alignment of service road in connection with construction of ROB(Transportation of second hand scrap but servicible 11/13mts long rail poles to site of work at a distance of about 30 kms including loading and unloading of rail poles,Scraping, cleaning, painting of Rail post & brackets with two coats of red oxide paint (before erection) followed by two coats of aluminium paint the paint should be of approved make and brands,Erection of Rail post with 1:3:6 cement concrete masonry foundation of Rail post below the ground level,Muffing of foundation of Rail post of (0.45x0.45x1)m with cement concrete mixture etc,Supply & fixing of MS galvanized anchor rod of size ¾” dia &8’ long complete with anchor plate (300x300x10)mm including foundation with P.C.C. 1:3:6 along with supply &fixing of stay wire 7/10 SWG stay insulator, clamp made of M.S. flat 65mm x 6mm and suitable fasteners,Supply & erection of earthing station as per CEE/CCC’s specification with GI earth electrode ,50mm dia and 3m long medium gauge TATA/JINDAL make G.I. pipe brackets at both ends and provided with alternate layer of charcoal and salt in the pit and connection with 4 SWG , G.I.Supply, fabrication and fixing of MS channel/angle of the following sizes. 125mmx65mmx6mm, 100mm x 50mm x 6mm, 65mmx65mmx6mm & 50mmx50mmx5mm,Supply and fixing of GI fasteners of appropriate sizes,Supply and delivery of single Core, 1000mm², 33KV XLPE insulated, armoured alluminium conductor cable.(Make: Gloster, MP-Cab,Poly-Cab make),Supply, installation, connection, testing and commissioning of outdoor type heat shrinkable end terminal jointing kit ( including jointing and sealing ) suitable for armored cable including connection of the cable with overhead conductor by supply suitable size aluminum sockets , jumpers and P.G/U-clamps, suitable for 33KV single core, 1000mm², XLPE insulated,Laying of cable partly through trench at a depth of 1m and filling with sand, brick work (16 nos. of bricks per meter run )or under the road by laying of G.I. pipe at depth of not less than 1m and refilling with earth and partly on rail post with supply of clamp made of M.S. flat,Supply and fixing of 33 KV Disc insulators complete with bolted type tension clamp & all other accessories. (The tension clamp should be of suitable size and conform to ISI specification),Supply, installation, testing & commissioning of 3 pieces non-linear resister type lighting arrestor confirming to IS :3070(P) (1) 1974 suitable for 3 wire 33KV overhead lines with a rated voltage of 30 KV (RMS) / 42KV (max.) with a nominal discharge current rating of 10 KA complete with all accesssories,Supply and delivery of 3 Core, 185mm²,11KV XLPE insulated, armored alluminium conductor cable.(Make: Gloster, MP-Cab, Polycab),Supply, installation, connection, testing and commissioning of outdoor type heat shrinkable end terminal kit ( including jointing and sealing ) suitable for armored cable including connection of the cable with overhead conductor by supplying suitable size aluminum sockets , jumpers and P.G/U-clamps, suitable for 11KV 3- core, 185 mm², XLPE insulated Alconductor armored cable. (Make :M-Seal, Denson, Raychom).Supply and fixing of 11 KV Disc insulators complete with bolted type tension clamp & all other accessories. (The tension clamp should be of suitable size and conform to ISI specification),Supply & fixing of 11KV pin insulators long with necessary hardware.,Supply & erection of bare fuse assembly for 3 phase supply suitable for 11 KV. (each phase containing two sets of pin insulators with fuse),Supply , laying , jointing fitting and fixing in position RCC Spun pipes of dia 300mm and collars Class-NP-3 conforming to IS:458 with cement : sand mortar (1:3) on the cement concrete bed,Supply & laying of medium gauge PVC pipe for protection of cable. ISI marked 100 mm dia.,Supply, fixing, connection, testing & commissioning of GOS of 11KV, 3 pole, 400A with locking arrangement and all other accessories including supply of 100mmx50mm channel & other hardware materials for fixing of GOS,Supply, installation, testing & commissioning of 11KV lightening arrester on top of the post with supply & fixing of 100mmx50mm M.S. Channel including separate earthing arrangement by 2x50mm dia .Medium gauge G.I. pipe TATA/Jindal make 3 m long as per CEE/CCCs specification as 4 SWG GI wire from earthing station to L.A.(Each set,Supply & erection of bare fuse assembly for 3 phase wire, 4 wire supply suitable for 440V (each phase containing two sets of pin insulators with fuse), Supply & fixing of large size L.T. Pin/Shackle insulators (as per ISI specification),Supply, installation, testing and commissioning of 3 phase, 50Hz,250KVA outdoor type distribution transformer of rating 11KV/415 V as per ISS:2026 conforming to CEE specification. (Make:ALSTHOM/BHEL/SIEMENS/CGL/A LIND/ Crompton greaves/Eastern),Supply and delivery of 4 core, 300 sq mm, 1100 V grade, XLPE/PVC insulated, armoured, alluminum conductor cable .(Make: Gloster /MPCAB, Poly cab or similar ISI Marked and CEES approved make),Supply, fixing, connection, testing and commissioning of out door type heat shrinkable end terminal joint kit suitable for 1100 volt grade XLPE / PVC 300 mm²x 4 core cable,Supply &laying of G.I. strip 50mmX6mm for earth connection of Transformer body , Generator body , Neutral connection , H.T. &L.T. panel body,Supply of medium gauge TATA / JINDAL make G.I. pipe for protection of cable on pole. (a) 150 mm dia,Supply and fixing of danger notice board conforming to ISI specification. Fixing to be done on rail pole by means of MS clamp made of MS flat,Supply and erection of anti climbing device,Supply and erection of cable route marker,Dismantling of ACSR from Insulators etc., and retensioning properly, jumpering with suitable size PG/U clamps of existing crossing,Cutting of rail post including dismantling of brackets, Insulators etc,Transportation of released materials (Rail poles, brackets, insulators, etc.) including loading and unloading from work site to Rly./Con. Store/BSEB store,Casting of foundation with earth excavation for Rail pole with PCC 1:3:6 (cement:Sand:Ballast). As per revelant IS foundation shall be 1mx1mx2m/1.5 mx1.5mx3m depth for rail poles along with muffing of size 0.5mx0.5mx0.5m the concourse aggregate should be of granite stone 40 mm graded for foundation and 20 mm for muffings (Cement and all other materials will be supplied by the contractor),Supply, Fabrication, fixing and connection of cable terminal board fully enclosed in MS sheet of 16 SWG thickness painted dust & vitamin proof water entry protected laying provision of 3/2 entry with rubber bushing gland one entry for incoming cable 25 mm 2/16mm 2 x 3.5 core and 2 no. out going cable 2 x 6 mm single core PVC wire etc including supply of hardware material,Dismantalling, shifting, erection & commissioning of 250 KVA outdoor transformer from existing foundation to new foundation ,