Health and Family Welfare Government Departments TDR #16834612

Medical Related Equipment and Supplies, Medical Equipments, Medical Equipment

Issued by Government Departments · kolkata, West Bengal
Tender Value
Ref. Documents
Estimated cost
Bid Submission
Ref Document
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
kolkata → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Supply Of Medical Items - BAG, BIOMEDICAL WASTE CARRYING BAG, PVC FREE AND CALCUUM FILLER FREE HMHDPE BAGS IN THE FORM OF ROLLS, SIZE 70CM X 80CM THICKNESS 40 MICRONS WITH BIO HAZARDS AND BMW LABELLING COLOUR YELLOW/RED CONFORMING TO SCHEDULE 2 & 3 OF BMW (M&H) RULES, 200 & IS 9738:2003 (POLYETHYLENE BAGS FOR GENERAL PURPOSE) Bag, Colostomy/Ilestomy one-pc transparent bag with oval shaped spiral adhesive including flex zones, hide away outlet and integrated charcoal filter-- custom cut 12-75 mm BAG, DISPOSABLE, THORACIC DRAINAGE SYSTEM Bain circuit (adult), Manually adjustable non metallic APL valve for MRI compatibility Bain circuit (paediatric), Manually adjustable non metallic APL valve for MRI compatibility Bandage, Crepe Bandage B.P. 10 cmX4 meter Bandage, Crepe Bandage B.P. 15 cm X 4 meter , Battery Operated Sternal Saw Sysytem Specification :- • All attachment should be made of stainless steel. • Should be fully autoclavable. Reciprocating Saw hand Piece: • Should have sternum guard • Should have minimum 1500 CM • Weight of hand piece with battery should be not more than 3.5 IBS • Saw noise level Should not more than 93 dp • Should be autoclavable except battery • Should be supplied with 2 blades of sternotomy surgery-effective length 34- 43 mm, width-1.3mm-9 mm. Saggital Saw handpiece (Redo sternum saw) • The Oscillating saw head should be 360 deg rotatable in eight steps. • Power – More than 220 W • CPM - 0-15,000 • Amplitude - 4˚47 • Weight – Less than 1650 gm including battery & lid • Should be supplied with 2 blades for TJR surgery – Effective Length 85- 95mm, Width 19-25mm, Thickness 0.89 – 1.37mm • Should be supplied with 2 blades for General Traumatology – Effective Length 35 – 65 mm, Width 10-50mm, thickness 0.5 – 0.9mm Battery • It should be NiMH/NiCd/Lithium Ion Battery. • The Battery should be of more than 1.7 Ah. BLiedaker Glass, Graduated, 1000ml, High-quality Borosilicate Glass that can be

AI Tender Summary

OUR REF NO 16834612
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 07-08-2018
Authority
Authority Name Central Medical Store Organization
Work Description Supply Of Medical Items - BAG, BIOMEDICAL WASTE CARRYING BAG, PVC FREE AND CALCUUM FILLER FREE HMHDPE BAGS IN THE FORM OF ROLLS, SIZE 70CM X 80CM THICKNESS 40 MICRONS WITH BIO HAZARDS AND BMW LABELLING COLOUR YELLOW/RED CONFORMING TO SCHEDULE 2 & 3 OF BMW (M&H) RULES, 200 & IS 9738:2003 (POLYETHYLENE BAGS FOR GENERAL PURPOSE) Bag, Colostomy/Ilestomy one-pc transparent bag with oval shaped spiral adhesive including flex zones, hide away outlet and integrated charcoal filter-- custom cut 12-75 mm BAG, DISPOSABLE, THORACIC DRAINAGE SYSTEM Bain circuit (adult), Manually adjustable non metallic APL valve for MRI compatibility Bain circuit (paediatric), Manually adjustable non metallic APL valve for MRI compatibility Bandage, Crepe Bandage B.P. 10 cmX4 meter Bandage, Crepe Bandage B.P. 15 cm X 4 meter , Battery Operated Sternal Saw Sysytem Specification :- • All attachment should be made of stainless steel. • Should be fully autoclavable. Reciprocating Saw hand Piece: • Should have sternum guard • Should have minimum 1500 CM • Weight of hand piece with battery should be not more than 3.5 IBS • Saw noise level Should not more than 93 dp • Should be autoclavable except battery • Should be supplied with 2 blades of sternotomy surgery-effective length 34- 43 mm, width-1.3mm-9 mm. Saggital Saw handpiece (Redo sternum saw) • The Oscillating saw head should be 360 deg rotatable in eight steps. • Power – More than 220 W • CPM - 0-15,000 • Amplitude - 4˚47 • Weight – Less than 1650 gm including battery & lid • Should be supplied with 2 blades for TJR surgery – Effective Length 85- 95mm, Width 19-25mm, Thickness 0.89 – 1.37mm • Should be supplied with 2 blades for General Traumatology – Effective Length 35 – 65 mm, Width 10-50mm, thickness 0.5 – 0.9mm Battery • It should be NiMH/NiCd/Lithium Ion Battery. • The Battery should be of more than 1.7 Ah. BLiedaker Glass, Graduated, 1000ml, High-quality Borosilicate Glass that can be
Basic Detail
Tender No
Bidding Type Tender
Location
City kolkata
State West Bengal
Key Dates
Publish Date 23 Jul 2018
Submission Date 07 Aug 2018
Open Date 01 Jan 0001
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD Ref. Documents
Exemption Not Available
Document List
e394bf29-acc4-4cd9-84e8-d1201d12050f.zip

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jan 01, 1900
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 07, 2018
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed

Tender Documents

Download All (ZIP) ↓
zip

e394bf29-acc4-4cd9-84e8-d1201d12050f.zip

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders