}

Distribution and Conditioning, Air Conditioning, Air Conditioner, Valves, Float Valves, Non Return Valve, Valve, Pipe Supply, Pipes, PVC Pipe, Construction, Civil Construction, Civil Work, Pole Construction, Water Proofing Work, Excavation, Excavation Wor, Jamnagar-Gujarat

Hindustan Petroleum Corporation Limited has published Distribution and Conditioning, Air Conditioning, Air Conditioner, Valves, Float Valves, Non Return Valve, Valve, Pipe Supply, Pipes, PVC Pipe, Construction, Civil Construction, Civil Work, Pole Construction, Water Proofing Work, Excavation, Excavation Wor. Submission Date for this Tender is 20-07-2016. Air Conditioner Tenders in Jamnagar Gujarat. Bidders can get complete Tender details and download the document.




Tender Notice

10090572
Distribution and Conditioning, Air Conditioning, Air Conditioner, Valves, Float Valves, Non Return Valve, Valve, Pipe Supply, Pipes, PVC Pipe, Construction, Civil Construction, Civil Work, Pole Construction, Water Proofing Work, Excavation, Excavation Wor
Tender
Indian
Gujarat
Jamnagar
20-07-2016

Tender Details

Water Tank Supplying And Installation Of Hdpe Water Tanks Of Approved Make Of 1000 Litre Capacity Including 300 Mm High Brick Masonry Pedestal Of 230Mm Thick In Cm 1:5, Providing 75Mm Thick Rcc 1:2:4 Slab With Reinforcement 8Mm Tor @150Mm C/C, Lifting The Tank , Making All Necessary Gi Connections To Inlet, Outlet, And Overflow Nozzles And Cleaning The Tank Before Commissioning. (Refer Attached Drawing) 139 160Mmdia-Pvc Swr Pipes Meters 516.2 Yes Description => Pvc Soil / Waste /Rain Water Pipe: Supplying And Laying The Pvc Pipe Conforming To Is 13592:92 Including Plain Or Door Type Bends, Shoes, Offsets, Clamps Junctions, Tees, Etc, Complete. Also Including Cutting, Bending & Supply And Laying Of 17 Swg Annealed Binding Wire Inside The Pipe For Pulling Cables In Future. 140 110 Mm Dia- Pvc Swr Pipes Meters 343.1 Yes Description => Pvc Soil / Waste /Rain Water Pipe: Supplying And Laying The Pvc Pipe Conforming To Is 13592:92 Including Plain Or Door Type Bends, Shoes, Offsets, Clamps Junctions, Tees, Etc, Complete. Also Including Cutting, Bending & Supply And Laying Of 17 Swg Annealed Binding Wire Inside The Pipe For Pulling Cables In Future.110 Mm Dia Pvc Pipe 141 80 Mm Dia Pvc Swr Pipes Meters 191.9 Yes Description => Pvc Soil / Waste /Rain Water Pipe: Supplying And Laying The Pvc Pipe Conforming To Is 13592:92 Including Plain Or Door Type Bends, Shoes, Offsets, Clamps Junctions, Tees, Etc, Complete. Also Including Cutting, Bending & Supply And Laying Of 17 Swg Annealed Binding Wire Inside The Pipe For Pulling Cables In Future. Size 80Mm Diameter 142 Nahani Trap Each 467.5 Yes Description => Nahani (Floor) Trap Providing And Fixing Pvc Floor Trap Of Self Cleansing Design Conforming To Is Specs With 100Mm Inlet, 75Mm Outlet And 150Mm Cp Hinged Grating Of 6Mm Thick With Rim. Rate Shall Include Making All Necessary Leak Proof Connections Etc . 143 Gully Trap With Chamber Each 2754.1 Yes Description => Gully Trap With Chamber Providing And Fixing Square Mouth Gully Trap Including Constructing 300 X 300 Mm Internal Size Brick Masonary Chamber With 230Mm Thick Brick Masonary In 1:5 Cement Mortar, Excavation, 75Mm Thick Power Control Centre 1:4:8 Bed, Plastering With Neat Cement Finish, Medium Duty Ci Cover With Frame Etc. Complete. 144 25Mm Dia Non Return Valve: Each 1124.5 Yes Description => Providing And Fixing Brass Non-Return Valve Gg/Leader Make Isi Marked Or Approved Equivalant 145 15Mm Dia Non Return Valve Each 611.3 Yes Description => Providing And Fixing Brass Non-Return Valve Gg/Leader Make Isi Marked Or Approved Equivalent - 15Mm Dia Non Return Valve 146 Float Valve Each 567.4 Yes Description => Float Valve Providing And Fixing Float Valve (Ball Cock) Of Polypropylene Or Synthetic Metal (Symet) Float And Rod Of Approved Make Of 25Mm Dia. Nominal Bore. 147 600X600x600mm Inspn. Chambers Each 5131.5 Yes Description => Providing And Constructing Inspection Chambers Of Size 600X600x600 Mm With 230Mm Thick Brick Masonary In 1:5 Cement Mortar, Excavation, 75Mm Thick Pcc 1:4:8 Bed, Plastering With Neat Cement Finish Etc. Complete. Incl. Ci ( Isi Make) Chamber Cover Ci Covers For Chambers / Inspection Chambers Etc With Frame Of 600X600 Mm Nominal Size With Seal, All Materials And Labour Complete.& Angle Frames To Support Etc Complete(Refer Attached Drawing) 148 450X450x600mm Inspn. Chambers Each 4440.5 Yes Description => Providing And Constructing Inspection Chambers With 230Mm Thick Brick Masonary In 1:5 Cement Mortar, Excavation, 75Mm Thick Power Control Centre 1:4:8 Bed, Plastering With Neat Cement Finish Etc. Complete. Incl. Ci ( Isi Make) Chamber Cover Ci Covers For Chambers / Inspection Chambers Etc With Frame Of 600X600 Mm Nominal Size With Seal, All Materials And Labour Complete.& Angle Frames To Support Etc Complete - 450X450x600mm Inspn. Chambers(Refer Attached Drawing) 149 Septic Tank (25 Person) Each 32640.2 Yes Description => Septic Tank Providing & Constructing Septic Tank Of Size 1200X2000x1800mm Depth With Excavation ,Pcc1:4:8 100Mm Thick Bed , 345/230Mm Thick Brick Masonary Wall In Cm 1:5 ,Rcc1:2:4 100Mm Thick Slab With 8Mm Tor Steel @150C/C Both Way , 115Mm Thick Baffle Wall With Rcc Beam At Bottom ,12Mm Thick Smooth Cement Plaster With Water Proofing Compound Inside And Exposed Outside Portion, Providing 600Mmx600mm Size Medium Duty Ci Cover, Providing 75Mm Dia Pvc Vent Pipe Etc. Complete.(Refer Attached Drawing) 150 Soakpit 2.5 Mdiax3.0 M. Depth Each 28855.2 Yes Description => Soak Pit Providing And Constructing Soak Pit Of 2.5M Dia X 3M Depth (Internal) In Brick Masonry Of Class 75 Design. Internal Size Of Shaft Shall Be Minimum Clear 1M With Minimum 230Thk. Walls In Cement Mortar 1:6 At Top 500Mm In Height And In Bottom 230Mm Wall In Height With 450Mmx450mm Dry Brick Honey Comb Shaft And Surrounded By Broken Brick Bats. The Outer Walls Of The Shaft Should Be 230 Mm Followed By 150 Mm Thick Layer Of 50-80 Mm Nominal Size Brick Aggregates Thereafter Followed By 150 Mm Thick Layer.( As Per Is 2470 Part 1 And Part 2 As The Case May Be)(Refer Attached Drawing) 151 Pt.Wiring- Switch Lt/Fan Each 845.1 Yes Description => Providing And Laying Point Wiring In Concealed Conduits For The Following Points Using Specified 1100V Grade Pvc Insulated, Frls Multistranded 3 X 1.5 Sqmm Copper Conductor Wires. Rate To Include Supplying, Laying And Securing In Position In Roof Slabs And Brick Walls Or Concrete Columns 25 Mm Dia Rigid Pvc Conduits (Conforming To Is 9537:Part 3: 1983) Of Approved Make With Necessary Accessories And Junction Boxes/Pull Boxes. Providing And Fixing In The Brick Walls Flush Type Metal Switch Boxes Of Approved Make Shade And Sufficient Size To Accommodate All 6A Modular Switches / 3 Pin Socket, Screws, Holders. Ceiling Roses And The Fan Regulator Wherever Required. Rate To Include Wall Chasing And Rough Plastering. Providing And Fixing Single Pole 5A Modular Plate Switches Of Approved Mk Or Anchor Roma/Havells /Finolex/Crabtree/Ssk Make And Of Approved Colour . One Switch Shall Be Provided For Each Light And Fan Point. Rate Also To Include Providing Main Circuit Wiring From Db To Switch Boards With 2 Runs Of 2.5 Sqmm Copper Wire And 1 Run Of 1.5 Sqmm Through Pvc Conduit. Also All Wires Shall Be Conforming To Is 694:1990. 152 6A Socket Switch Each 598 Yes Description => Providing And Laying Point Wiring In Concealed Conduits For The Following Points Using Specified 1100V Grade Pvc Insulated, Frls Multistranded 3 X 1.5 Sqmm Copper Conductor Wires. Rate To Include Supplying, Laying And Securing In Position In Roof Slabs And Brick Walls Or Concrete Columns 25 Mm Dia Rigid Pvc Conduits (Conforming To Is 9537:Part 3: 1983) Of Approved Make With Necessary Accessories And Junction Boxes/Pull Boxes. Providing And Fixing In The Brick Walls Flush Type Metal Switch Boxes Of Approved Make Shade And Sufficient Size To Accommodate All 6A Modular Switches / 3 Pin Socket, Screws, Holders. Ceiling Roses And The Fan Regulator Wherever Required. Rate To Include Wall Chasing And Rough Plastering. Providing And Fixing Single Pole 6 A Socket Modular Plate Switches Of Approved Mk Or Anchor Roma/Havells /Finolex/Crabtree/Ssk Make And Of Approved Colour . One Switch Shall Be Provided For Each Light And Fan Point. Rate Also To Include Providing Main Circuit Wiring From Db To Switch Boards With 2 Runs Of 2.5 Sqmm Copper Wire And 1 Run Of 1.5 Sqmm Through Pvc Conduit. Also All Wires Shall Be Conforming To Is 694:1990. But For 6A Socket Controlled By One 6A Switch On The Same Lighting Board 153 6A Socket Switch Indepenently Each 702.6 Yes Description => Providing And Laying Point Wiring In Concealed Conduits For The Following Points Using Specified 1100V Grade Pvc Insulated, Frls Multistranded 3 X 1.5 Sqmm Copper Conductor Wires. Rate To Include Supplying, Laying And Securing In Position In Roof Slabs And Brick Walls Or Concrete Columns 25 Mm Dia Rigid Pvc Conduits (Conforming To Is 9537:Part 3: 1983) Of Approved Make With Necessary Accessories And Junction Boxes/Pull Boxes.Providing And Fixing In The Brick Walls Flush Type Metal Switch Boxes Of Approved Make Shade And Sufficient Size To Accommodate All 6A Modular Switches / 3 Pin Socket, Screws, Holders. Ceiling Roses And The Fan Regulator Wherever Required. Rate To Include Wall Chasing And Rough Plastering.Providing And Fixing Of Approved Mk Or Anchor Roma/Havells /Finolex/Crabtree/Ssk Make And Of Approved Colour . One Switch Shall Be Provided For Each Light And Fan Point.Rate Also To Include Providing Main Circuit Wiring From Db To Switch Boards With 2 Runs Of 2.5 Sqmm Copper Wire And 1 Run Of 1.5 Sqmm Through Pvc Conduit. Also All Wires Shall Be Conforming To Is 694:1990. But For 6A Socket Controlled By One 6A Switch On The Same Lighting Board But For 6A Socket Controlled By One 6A Switch Independently Mounted Including Providing Wiring With 3 Runs Of 1.5 Sqmm Pvc Insulated Copper Wire Through Pvc Conduit 154 6/16A Socket Switch Each 1038.1 Yes Description => Providing And Laying Point Wiring In Concealed Conduits For The Following Points Using Specified 1100V Grade Pvc Insulated, Frls Multistranded 3 X 1.5 Sqmm Copper Conductor Wires. Rate To Include Supplying, Laying And Securing In Position In Roof Slabs And Brick Walls Or Concrete Columns 25 Mm Dia Rigid Pvc Conduits (Conforming To Is 9537:Part 3: 1983) Of Approved Make With Necessary Accessories And Junction Boxes/Pull Boxes.Providing And Fixing In The Brick Walls Flush Type Metal Switch Boxes Of Approved Make Shade And Sufficient Size To Accommodate All 6A Modular Switches / 3 Pin Socket, Screws, Holders. Ceiling Roses And The Fan Regulator Wherever Required. Rate To Include Wall Chasing And Rough Plastering.Providing And Fixing Approved Mk Or Anchor Roma/Havells /Finolex/Crabtree/Ssk Make And Of Approved Colour . One Switch Shall Be Provided For Each Light And Fan Point.Rate Also To Include Providing Main Circuit Wiring From Db To Switch Boards With 2 Runs Of 2.5 Sqmm Copper Wire And 1 Run Of 1.5 Sqmm Through Pvc Conduit. Also All Wires Shall Be Conforming To Is 694:1990. But For 6A Socket Controlled By One 6A Switch On The Same Lighting Board For 6/16A Socket Controlled By 16A Switch Independently Mounted Including Providing Wiring With 2 Runs Of 2.5 Sqmm And 1 Run Of 1.5 Sqmm Pvc Insulated Copper Wire Through Pvc Conduit 155 Air Conditioner Point Each 2301.2 Yes Description => Providing And Laying Point Wiring In Concealed Conduits For The Following Points Using Specified 1100V Grade Pvc Insulated, Frls Multistranded 3 X 1.5 Sqmm Copper Conductor Wires. Rate To Include Supplying, Laying And Securing In Position In Roof Slabs And Brick Walls Or Concrete Columns 25 Mm Dia Rigid Pvc Conduits (Conforming To Is 9537:Part 3: 1983) Of Approved Make With Necessary Accessories And Junction Boxes/Pull Boxes.Providing And Fixing In The Brick Walls Flush Type Metal Switch Boxes Of Approved Make Shade And Sufficient Size To Accommodate All 6A Modular Switches / 3 Pin Socket, Screws, Holders. Ceiling Roses And The Fan Regulator Wherever Required. Rate To Include Wall Chasing And Rough Plastering.Providing And Fixing Approved Mk Or Anchor Roma/Havells /Finolex/Crabtree/Ssk Make And Of Approved Colour . One Switch Shall Be Provided For Each Light And Fan Point.Rate Also To Include Providing Main Circuit Wiring From Db To Switch Boards With 2 Runs Of 2.5 Sqmm Copper Wire And 1 Run Of 1.5 Sqmm Through Pvc Conduit. Also All Wires Shall Be Conforming To Is 694:1990. For 6A Socket Controlled By One 6A Switch On The Same Lighting Board Same As Above But For For Air Conditioner Point With 2 Runs Of 4 Sqmm (P&N)And 1 Run Of 2.5 Sqmm (Earthing) Pvc Insulated , Frls Multistrand Copper Cable In 25 Mm Dia Pvc Conduict From Mcbdb To 20 A Powersocket. The Conduit Shall Be Partly/Fully Concealed In All Types Of Wall, Ceiling Etc Complete With All Accessories, Wiring, Termination, Connected Civil Works, Rough Plastering Etc Including Supply And Fixing Of 20A Industrial Socket Controlled By 20A Spmcb Of Mds/Havels Make.

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail