TDR : 57159106
Central Public Works Department

Tender Brief :

Delhi, Delhi

A/R & M/O To Jaisalmer House, New Delhi During 2026-27. (SH:- Providing Man Power Services Of MTS, AUTO CAD Operator For O/O Chief Architect (PRND), CPWD, Room No 001, Sankalp Bhawan, New Delhi And Providing Services Of Data Entry Operator For Office

Published: 24 Aug 2026
Opening: 31 Aug 2026
Closing: 31 Aug 2026
Amount: 5.33 Lakhs
EMD: 10668
Tender Fee: Ref. Documents


Works Accounting Services Acid Storage Tank Acoustical Work Advertising Agency Aerial Advertisement
4
Days Left
Tender Summary / Eligibility Criteria
A/R & M/O To Jaisalmer House, New Delhi During 2026-27. (SH:- Providing Man Power Services Of MTS, AUTO CAD Operator For O/O Chief Architect (PRND), CPWD, Room No 001, Sankalp Bhawan, New Delhi And Providing Services Of Data Entry Operator For Office Of Subdivision-II Under Vigyan Bhawan Division, In 10/11 Jamnagar House, New Delhi)
Documents Download All
5e6a0986-a02d-4beb-a02f-2f56ddc02ec3
5e6a0986-a02d-4beb-a02f-2f56ddc02ec3.html
DocumentsList
DocumentsList.zip
No Boq
No Corrigendum
Probable Bidders

AI engine predicts probable bidders to help you bid strategically.

MSME Exception
Explore More →
Technical
Tender involves procurement of high capacity electrical equipment including diaphragm coupling of pump & motor with 90kW capacity at 2900 RPM. The project scope includes installation, testing, commissioning and operational handover.
Previous / Similar Result
BRR : 10606969 Outsourcing Of House Keeping And Conservency Services For The Office Of Cwe No 2 , Brichgunj , Port Blair , Data Entry OperatorOut Sourcing Of Services For Data Entry Operator For Compilation Of Reports And Returns , Entry Of Various Data , Generaton Of Reports , Keeping Record Of Progress Of Works , Stores And Entering Data In Computer To The Entire Satisfaction Of Officer-In Charge . Note:- ( I ) The Contractor Shall Deploy - 03 Nos Of Data Entry Operators Daily . ( Ii ) The Data Entry Operator Shall Attend The Office During Working Hours As Prescribed And Report To Officer-In-Charge . ( Iii ) The Data Entry Operator Shall Have Adequate Knowledge In Operating System With Ms Office . ( Iv ) The Data Entry Operator Shall Having Training In His/Her Trade Of Minimum 02 ( Two ) Years Of Experience With Minimum Educational Qualification Of Intermediate With Three Months Certificate Course In Ms Office ( V ) In Case Any Variation In Manpower As Indicated In Column No . 4 Of Boq Due To Any Reasons / Or Any Manpower Held In Department Or Any Policy Change Contractor Shall Have No Claim On That Account . , Filing AssistantOut Sourcing Of Services Of Filing Assistant For Filing All Documents . Filing Assistant Shall Maintain Serial Number Of Files , Opening Of New Files According To Main Heading Of The Subject Dealt With Various Sections , Each Letter In Files Shall Be Serially Numbered With Back Reference/Forward Reference , Docket/Index Sheet And Updating Of Files , Handling Of Files All As Directed And To The Entire Satisfaction Of Officer-In Charge . Note:- ( I ) The Contractor Shall Deploy - 05 Nos Of Filing Assistants Daily . ( Ii ) The Filing Assistant Shall Attend The Office During Working Hours As Prescribed And Report To Officer-In-Charge . ( Iii ) The Filing Assistant Shall Have Adequate Knowledge And Having Experience Of Two Year As Office Assistant/Filing Assistantce . ( Iv ) The Filing Assistant Shall Be Trained In His/Her Trade With Minimum Educational Qualification Of Intermediate . ( V ) In Case Any Variation In Manpower As Indicated In Column No . 4 Of Boq Due To Any Reasons / Or Any Manpower Held In Department Or Any Policy Change Contractor Shall Have No Claim On That Account . , Printing AssistantOut Sourcing Of Services Of Printing Assistant For Preparation Of Power Point Presentations , Taking Print Outs Of Design , Engineering & Auto Cad Drawings And Assisting Draughtsman In E-6/E-2 Design Sections , Updating And Entering Data In Computers To The Entire Satisfaction Of Officer-In Charge . Note:- ( I ) The Contractor Shall Deploy - 01 No Of Printing Assistant Daily . ( Ii ) The Printing Assistant Shall Attend The Office During Working Hours As Prescribed And Report To Officer-In-Charge . ( Iii ) The Printing Assistant Shall Have Adequate Knowledge In Operating System With Ms Office/Auto Cad . ( Iv ) The Printing Assistant Shall Be Trained In His/Her Trade Having Minimum 02 ( Two ) Years Of Experience With Minimum Educational Qualification Of Intermediate With Three Months Certificate Course In Ms Office/Auto Cad . ( V ) In Case Any Variation In Manpower As Indicated In Column No . 4 Of Boq Due To Any Reasons / Or Any Manpower Held In Department Or Any Policy Change Contractor Shall Have No Claim On That Account . , SafaiwalaOutsourcing Internal Conservancy Services For The Bldgs Viz Office Complex Including Verandahs , Toilets , Corridors , Roofs , Drains . , Cleaning And Disinfecting Of Toilets , Brooming And Mopping Of Rooms , Verandahs , Corridors With Disinfectants , Re-Arranging Of Furniture , Sweeping The Surroundings Of Office Complex Including Roads And Paths , Cleaning Of Windows , Glass Frame , Doors , Computers , Printers , Fax Machine , Ups , Telephone Instruments Xerox Machine , Dusting Of Furniture , Ceiling Fans , Removal Of Cobwebs , Etc . , To The Entire Satisfaction Of Adm Officer/Section Heads . The Cost Of Various Consumable Items Including Disinfectants Like Phenyl , Acid , Naphthalene Ball , Cleaning Agents Like Vim , Detergents , Broom , Brushes , Duster Etc Shall Be Deemed To Be Included In Quoted Rates . Note:- ( I ) The Contractor Shall Deploy - 01 No Safaiwala Daily . ( Ii ) The Safaiwala Shall Attend The Office During Office Time From 07:00 Am To 03:00 Pm Or As Directed By Officer In Charge . ( Iii ) In Case Any Variation In Manpower As Indicated In Column No . 4 Of Boq Due To Any Reasons / Or Any Manpower Held In Department Or Any Policy Change Contractor Shall Have No Claim On That Account . ( Iv ) Safiwala Shall Have Minimum Educational Qulification Of High School And Minimum Two Year Of Exprience In The Trade .
Contract Date : Ref. Documents   |   Contract Value : Ref. Documents
BRR : 9443197 Tender For Repair/Renovation And Up-Gradation Work For Invest Up Office Of 4Th Floor Side-A, Miscellaneous Work At 2Nd And 6Th Floor At Picup Bhawan, Gomti Nagar, District-Lucknow (U.P.)., 1 Repair/Renovation and Up-gradation work for Invest Up Office of 4th Floor Side-A, Miscellenous work at 2nd & 6th Floor at PICUP Bhawan, Gomti Nagar, District-Lucknow (U.P.). 2 INTERIOR WORK 3 Providing & Fixing of at all height false ceiling including providing and fixing of frame made of special section power pressed from m.s. sheet and galvonised in accordance with zinc coatingof grade 350 as per IS 277and consisting of angle cleat 25x1.6mm with flanges of 27mm and 37mmat 1200mm c/c one flangedfix to the ceiling with dash fastener 12.5mm dia and and 40mm long with 6mm dia boltto the angle hangers of 25x25x0.55 mm of required lengthened other end of angle hanger being fixed with nut and bolts to GI channel 45x15x0.90mm running at the rate of 1200 mm c/c to with the ceiling section 0.5mm thick button wedges of 80mm with tappered flenges of 26 mm each having clips of 10.5mm.at 450mmc/ cshall be fixed in direction perpendicular to GI channels with connecting clipsmade out of 2.64MM diax230mm longGI wire at every junction including fixing the gypsumboard with ceiling section and perimetre channels 0.50 mm thick 27mm high having flenges of 20mm and 30mm long ,perimeter of ceiling fixed to wall /partitionwith help of rawl plugs at 450mm c/c with 25 mm long drive all screws @230mm interval including jointing and fixingto a flush finish of tapperedend sq edge of board with recommended filler jointing and tapper finisher and two coat of primer suitable for board as per manufacturers specification and also including the cost of making of openning for light fittings grills diffusers cutouts made with frame of perimeter channelssuitably fixed all complete as per drawing and specification and direction of engineer incharge but excluding the cost of painting. 12.50mm thick tapered edge gypsum board. 4 Providing and fixing Gl Clip in Metal Ceiling System of 600x600 mm module which includes providing and fixing C wall angle of size 20x30x20 mm made of 0.5 mm thick pre painted steel along the perimeter of the room with help of nylon sleeves and wooden screws at 300 mm center to centre, suspending the main C carrier of size 10x38x10 mm made of G.I steel 0.7 mm thick from the soffit with help of soffit cleat 37x27x25x1.6 mm, rawl plugs of size 38x12 mm and C carrier suspension clip and main carrier bracket at 1000 mm c/c. Inverted triangle shaped Spring Tee having height of 24 mm and width of 34 mm made of Gl steel 0.45 mm thick is then fixed to the main C carrier and in direction perpendicular to it at 600 mm centers with help of suspension brackets. Wherever the main C carrier and spring T have to join, C carrier and spring T connectors have to be used. All sections to be galvanized @ 120 gms/sqm (both side inclusive), fixing with clip in tiles into spring T with : GI Metal Ceiling Clip in plain Beveled edge global white color tiles of size 600x600 and 0.5 mm thick with 25 mm height, made of G I sheet having galvanizing of 100 gms/ sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation. 5 Providing & Fixing of Armstrong Mineral Fibre Acoustical Suspended Ceiling System with Dune Max (Bevelled Tegular) Edge Tiles With Armstrong 15mm Exposed GRID.The tiles should have Humidity Resistance (RH) of 99%, NRC 0.7, Light Reflectance ≥85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 20mm , suitable for Green Building application, with Recycled content of 63%.The tile shall be laid on Armstrong Suprafine 32 with 15 mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 32mm and a load carrying capacity of 8.8 Kgs/M2 & pull out strength of 100Kgs. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system of Armstrong make. INSTALLATION: To comprise main runner spaced at 1200mm centres securely fixed to the structural soffit using Armstrong suspension system (specifications below) at 1200mm maximum centre.The First/Last Armstrong suspension system at the end of each main runner should not be greater than 450mm from the adjacent wall. Flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm centre to form 1200 x 600 mm module.Cut cross tees longer than 600mm require independent support.600 x 600mm module to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200 mm cross tees. Perimeter trim to be Armstrong wall angles of size 3000x19x19mm, secured to walls at 450 mm maximum centres. ARMSTRONG SUSPENSION SYSTEM - Armstrong make Anchor Fastener, Hanger Wire 2.5mm dia, Hook Clip with J Wire assembly. Approved Makes - Armstrong, Shera, Nitco. 6 Providing & fixing Armstrong Vertical Linear Baffle Ceiling made out of GI Extrusion in GI alloy grade. The baffle blade shall be in size of 100x 25 x 3600mm. The baffle blade shall be suspended using Slotted U-profile at on-center spacing in multiples of 25mm. longer lengths of Baffle to be connected by Baffle Joiner and the ends to be fixed with End caps.Installation of U-Grid: The U profile to be suspended at every 1200mm on-centre using 6mm threaded rod from the structural soffit using U-profile hanger. U-profile splice to be used to join more than one U profiles of length 3.75M. 1st U-Grid Channel must be no more than 400mm from the perimeter. as per the approveddesign all complete as per drawing, specification and direction of Architect/ Engineer -in-Charge. APPROVED MAKE - Armstrong/ HiSteel/Equivalent 7 Providing and Fixing Armstrong or equivalent SoundScapes - Acoustical clouds which are 30 mm thick, flat glass fiber panelswith Humidity ResistanceRH 90% & Recycled Content of minimum 30%, come in various shape options like Square / Convex / Concave / Circle / Hexagon / Trapezoid / Parallelogram (Left & Right) / Rectangle (Small & Large) and in standard Traffic White color with LR 90% or in the color specified by the Architect / Engineer incharge (White/ Shell/ Tangerine/ Cranberry/ Moss/ Kiwi/ Reef/ Lagoon/ RAL co-ordinated*) . The size and sound absorption details are as below:Sr. No. ShapeNominal SizeSound Absorption – Metric Sabin1. Square1200x1200mm2.482. Convex1200x1200mm2.283. Concave1200x1200mm1.944. Circle 1200x1200mm2.125. Hexagon1200x1200mm1.616. Trapezoid 1200x1200mm2.157. Left Parallelogram 1200x1200mm2.158. Right Parallelogram1200x1200mm2.15The back of each panel to have embedded square frame bracket system of 610x610mm in which provisions are already made for integration of installation system for suspension of individual or grouped panels. INSTALLATION: The panels to be suspended individually using the SoundScapes Deck hanging kit. Each kit to consist of gripper structure anchors with an outer diameter of 16mm and height 23mm, aircraft cables of 1.5mm dia 2.44 LM in length and bottom end cable adjusters of 8.9mm outer diameter.Each panel to be suspended using the aircraft cables which are suspended from the soffit using the gripper structure anchors and its other end passing through the bottom end cable adjuster which are screwed in the 4 corners of the frame bracket system. The height & level of the panels can be adjusted using the bottom end cable adjusters. APPROVED MAKE - Armstrong/ Saint Gobain/ SAS 8 Providing and fixing of 12 mm ThickLaminated wooden flooringrange grand illusion/studio Classification of Use 23/32 (Heavy Domestic/Domestic) with a Surface Abrasion Resistance of class AC3 (average 4500 cycles), Impact Resistance of IC2 (EN13329), Resistance to Cigarette Burn with a rating of 5 (EN 438-2:15), Swelling after 24 hrs in water of 15% (EN13329), Modulus of Rupture of 53.3 newton/mm2, Internal Bond 1.78 newton/mm2, Surface Soundness of 1.3 newton/mm2 (EN 13329:2000) with a 0.2mm thick wear layer on top of a High Density Fiber substrate core (density > 850 Kg/M3) of plank size 1212 mm X 137 mmhaving Uni fitlocking arrangement (lock strength > 1000 lbs/ft) with an underlayment made of natural colour foam , with accessories like End profile, Transition profile, reducer, etc. complete. The rate includes cost of all materials, accessories, labour, HOM, etc., complete at all levels. (The Shade, pattern etc., to be approved by Engineer in charge)Make-FloorMaster/Armstrong/Haro. all complete as per drawing, specification and directionas approved by the Architect/ Engineer -in-Charge. Make-Armstrong,Mikasa,Luxe Equivalent 9 Supply & fixing of first radiant/first line/Japan carpet tile tufted 1/10” loop carpet tile100% PA6 solution dyed aquation backing back to back modified bitumen, 10% recycled content included,fire resistant EN-1350-1B,,S1,pile height Ca2.9 mm, total weight ca 4300 gm/m2,pile densityca 0.114gm/cm3,thermal resistant ISO8302.0.047m2 K/W,impact noise rating ISO10140(1000Hz) tile size should be (500 cm X 500 cm) duly installed on smooth and hard surface with company recommended adhesive. 10 Providing and laying of Double Charged floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x1200mm 11 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm 12 Grouting the joints of flooring tiles having joints using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. 13 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab colour black, Cherry/Ruby red Area of slab over 0.50 sqm 14 Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 15 Providing & Making & Fixing of Commercial Wall Panneling made with Aluminium Section of 2x1 @ 2CC frame work cladded with 12MM Ply complete with painted or polishe.as per the approveddesign all complete as per drawing, specification and directionas approved by Engineer -in-Charge. 16 Providing & Making & Fixing of Commercial Wall Partition made with Aluminium Section of 2x1 @ 2CC frame work cladded with 9MM Ply on Both Side complete with painted or polishe.as per the approveddesign all complete as per drawing, specification and directionas approved by Engineer -in-Charge. 17 Providing & Making & Fixing of Wall Panneling made with 1MM Laminate & 5.5MM MDF on Existing Surface complete with painted or polishe.as per the approveddesign all complete as per drawing, specification and directionas approved by Engineer -in-Charge. 18 Providing & Making & Fixing of Wall Panneling made with Coloured Lacquered Glass on Existing Surface complete with Melamine Polishe.as per the approveddesign all complete as per drawing, specification and directionas approved by Engineer -in-Charge. 19 Providing & Fixing of full height Single glazed partition using 10mm thick toughened Glass fixed with proprietary anodized aluminium sections of size 26x30mm (H) on top, bottom, horizontal & vertical. Rate to include required accessories as per the manufacturers specifications and shall be inclusive of all accessories like Gaskets. Glass to glass joints to be sealed with Double sided 2mm Thick transparent tape.The glasses to be butt jointed with 2 to 3mm edge chamfer & edge polishing all around.Achieving value of 31 dB. ( Rate is not included for door frames) Finish - Black Anodised, Partition Height - 2400mm, System - Micra I, Glass - 10mm Toughened Glas, Make - Liko-s 20 Providing & fixing of 12 mm Toughened Glass Door with all hardwareas per design with edge polish m/c top & bottom pivot and bottom lockwith handle all complete as per drawing, specification and directionas approved by Engineer -in-Charge. 21 Providing, fabricating & placing single leaf single swing Solid flush door with Vision panel (Laminated finish) door with 40mm thick wooden leaf. The door frame of size 70 x 50mm shall be formed with heavy duty anodised aluminium door, fixed to dry wall partition. Rate to include providing & fixing in position necessary Geze make standard stainless steel brush finished hardwares Hinges: GEZE Flush HingesHandle: Mortise lever Handle Door Closer: TS3000V Exposed door closer Drop Seal:Concealed Dropseal Athmer Lock : Mortise Lock, Cylinder: Cylinder with both side keys (with 3 keys) Floor Stop:Door stopper, System - Micra I, Shutter- 40mm thk shutter with both side laminated, Make - Liko-s 22 Supply&Fixingofwindowsmadefrommulti chambered UPVC profiles of minimum 60/108 mm thicknessof (Wintechmakeorequivalent)in natural from stailized for heat, light, impact & UV radiation. The UPVC profiles should be reinforced withgalzvanizedsteelprofilesofdesigned thickness.Floatglassofapprovedcolourin 4/5/6/8 mm or as desired by the costumer shall be fixed with heveled beads. All openable / sliding sashes shall be having grey/black colored weather seal fitted in continuous lenghts made from bubble PTV Rubber & side Hung with 90L openin friction syats of rust proof stainless steel with provision of multipoint lockng system (casement only) made from Espag rods (coated steel) all handle shall be made from die Cast zinc alloy in white finish only as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. 23 Providing & Fixing of Roller Blinds with Hand Rail of approved shade as per drawing & specificationas approved by Engineer -in-Charge. 24 Providing & Fixing of Zebra Blinds with Hand Rail of approved shade as per drawing & specificationas approved by Engineer -in-Charge. 25 Providing & Fixing of Plotter Cutted Designer Film of approved shade as per drawing & specificationas approved by Engineer -in-Charge. 26 Providing & Fixing of Plotter Cutted Designer Coloured Vinyl of approved shade as per drawing & specificationas approved by Engineer -in-Charge. 27 Providing & Fixing of Wall Paper of approved shade as per drawing & specificationas approved by Engineer -in-Charge. 28 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 29 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 30 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm 31 Providing & Fixing of Square Shape Polmer Planter of Size (375Wx375Dx400HT) With Thermocol Packing & Double Layer of Pabbles With Artificial 36Plants of approved shade as per drawing & specificationas approved by Engineer -in-Charge.MR 32 Providing & Fixing of Round Shape Polmer Planter of Size (375DIA X 375HT) With Thermocol Packing & Double Layer of Pabbles With Artificial 36Plants of approved shade as per drawing & specificationas approved by Engineer -in-Charge.MR 33 Providing & Fixing of Rectangular Shape Polmer Planter of Size (600Wx325Dx375HT) With Thermocol Packing & Double Layer of Pabbles With Artificial 36Plants of approved shade as per drawing & specificationas approved by Engineer -in-Charge.MR 34 Providing & Fixing of Oval Shape Polmer Planter of Size (325DIA X 500HT) With Thermocol Packing & Double Layer of Pabbles With Artificial 36Plants of approved shade as per drawing & specificationas approved by Engineer -in-Charge.MR 35 Providing & Fixing of Oval Shape Polmer Tower Planter of Size (200DIA X 600HT) With Thermocol Packing & Double Layer of Pabbles With Artificial 36Plants of approved shade as per drawing & specificationas approved by Engineer -in-Charge.MR 36 Providing & Fixing of Oval Shape Ceramic Tower Planter of Size (200DIA X 600HT) With Thermocol Packing & Double Layer of Pabbles With Artificial 60Plants of approved shade as per drawing & specificationas approved by Engineer -in-Charge.MR 37 Providing & Fixing of Photo Frames Having Size (1200WX450HT) of Varanasi Picture in Coloured Canvas Printswith wooden frame borders & Non Reflective glasscomplete as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. 38 Providing & Fixing of Photo Frames Having Size (600WX900HT) of Picture in Coloured Canvas Printswith wooden frame borders & Non Reflective glasscomplete as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. 39 Providing & Fixing of Photo Frames Having Size (1200WX750HT) of Varanasi Picture in Coloured Canvas Printswith wooden frame borders & Non Reflective glasscomplete as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. 40 Providing & Fixing of Photo Frames Having Size (500WX375HT) of Varanasi Picture in Coloured Canvas Printswith wooden frame borders & Non Reflective glasscomplete as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. 41 Providing & Fixing of Photo Frames Having Size (600WX600HT) of Uttar Pradesh Sarkar in Black & White/Coloured Canvas Printswith wooden frame borders & Non Reflective glasscomplete as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. 42 Providing & Fixing of Photo Frames Having Size (650WX650HT) of Uttar Pradesh Sarkar in Black & White/Coloured Canvas Printswith wooden frame borders & Non Reflective glasscomplete as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. 43 Providing & Fixing of Photo Frames Having Size (400WX400HT) of Shri Ram Mandirin Black & White Canvas Printswith wooden frame borders & Non Reflective glasscomplete as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. 44 Providing & Fixing of Photo Frames Having Size (725WX725HT) of Sandwitched Flower in Colour Canvas Printswith wooden frame borders & Non Reflective glasscomplete as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. 45 Providing & Fixing of Photo Frames Having Size (475WX1200HT) of Invest UP in Colour Canvas Printswith wooden frame borders & Non Reflective glasscomplete as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. 46 Providing & Fixing of Photo Frames Having Size (450WX600HT) of Invest UP in Colour Canvas Printswith wooden frame borders & Non Reflective glasscomplete as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. 47 Providing & Fixing of Photo Frames Having Size (400WX600HT) of Invest UP in Colour Canvas Printswith wooden frame borders & Non Reflective glasscomplete as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. 48 Providing & Fixing of Signages of Size (1500 x 188)MM Made of 12mm Corian CNC Cut Letters & Fixed on Existing Wall Surface of INVEST UP, complete as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. 49 Providing & Fixing of Signages of Size (1175 x 350)MM Made of Multi Layered Signage made with 5mm & 3mm Thick Acrylic & UV Prints on Base Acrylic & Acrylic Letters of INVEST UP LOGO, complete as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. 50 Providing & Fixing of Signages of Size (200 x 200)MM Made of Side Moulded Signages made with Premium Laminate & Acrylic Laser Cut Letters as per deisgn & Multi Layering with Wooden Finish as base of Male, Female Toilet & Pantry, complete as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. 51 Providing & Fixing of Signages of Size (450 x 200)MM Made of Side Moulded Signages made with Premium Laminate & Acrylic Laser Cut Letters as per deisgn & Multi Layering with Wooden Finish as base of Conference Hall, complete as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. 52 Providing & Fixing of Signages of Size (2400 x 1200)MM Made of UV Prints on Lacquered Glass with Pre Coat & 3 Layer Prinitng of Invest UP Logo, complete as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. 53 Providing & Fixing of Signages of Size (350 x 200)MM Made of 3 Layer Name Plates made with Black Acrylic as base & UV Prints on Clear Acrylic as 2nd Layer & 3rd Layer being Acrylic Letters of IIDC, CEO & ACEO Room, complete as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. 54 Providing & Fixing of Signages of Size (875 x 875)MM Made of 6mm Clear Acrylic Laser Cut with UV Prints from Back Side & Heavy White Ink as base & fixed with Spacers, complete as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. 55 Providing & Fixing of Signages of Size (1200 x 600)MM Made of 3D Embossed Acrylic Letters with Multi Layering made with Acrylic & ACP & UV Prints of Invest UP Logo, complete as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. 56 Providing & Fixing of Signages of Size (600 x 150)MM Made of UV Prints on Clear Acrylic Sheet 3mm Black Acrylic Laser Cut Letters Invest UP, complete as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. 57 Providing & Fixing of Signages of Size (600 x 75)MM Made of UV Prints on Clear Acrylic Sheet 3mm Black Acrylic Laser Cut Letters 2nd, 4rth & 6th Floor, complete as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. 58 Furniture Work 59 Table of Size - 1800W X 900D X 750HT Having Side Storage of - 900W X 450D X 750HT & Back Storage of - 1350W X 450D X 750HT & 450 Extended Top Specifications Table Top: 25mm thick Pre laminate particle board with 2mm PVC edge Lipping on all exposed edges (Straight/Reverse waterfall edge) Support: End Legs : Powder coated Al die casted Enrich legs Modesty Panel: 18mm thk pre lam board with 2mm PVC edge lipping of 450mm Ht. Wire Management: 450mm Aluminium Flip Up and provision to mount swicthes and sockets on PVC cable dump and Vertical wire entry cover or vertebra for wire uptake from floor to cable dump The storage will be made in 18 MM PLB (Pre laminated board) with the density of 680kg/m³ and 18 mm thick one side pre-laminate board confirming to IS 12406 : 2013. Surface: CPL (continuous pressure laminate) in 0.5mm thickness in melamine finish. The PLB will be confirming to E-1 Grade as per the JIS A 5905-2003 standards and approved shade confirming to IS-12823:1990.The back of storage will be made in 9 MM PLB (Pre laminated board) with the density of 680kg/m³ and 18 mm thick one side pre-laminate board confirming to IS 12406 : 2013. Surface: CPL ( continuous pressure laminate) in 0.5mm thickness in melamine finish. Storgage will be provided with edge banding 2 mm thick PVC edge band will confirm to DIN 68861 for resistance to clearers. The Hot melt glue used for fixing the PVC edge band should have ISO 9001- 2015 quality certification and confirm to ASTM D 4499 standards for viscosity and thermal stability. The edge band material should have Shore D hardness of 79± 4. storage will have two adjustable shelves 60 Table of Size - 1500W X 750D X 750HT Having Side Storage of - 900W X 450D X 750HT. The main table shall be made of 25mm thick PLB one side pre-laminate board confirming to IS-14587:1998. Soft closing access flap with in-built power box to be provided on work surface for wire management. Return table Work Surface should be made of 25mm thick PLB one side pre-laminate board confirming to IS-14587:1998. PLB will be E1-P2 grade and approved shade. Confirming to IS-12823:1990. 2 mm thick PVC edge band will confirm to DIN 68861 for resistance to clearers. The edge band material should have Shore D hardness of 79± 4. The Hot melt glue used for fixing the PVC edge band should have ISO 9001- 2015 quality certification confirming to ASTM D 4499 standards for viscosity and thermal stability. The edges should be PVC Edge banded with matching finish or have an option of reverse water fall edges.Modesty Panel shall be made of 18mm thick PLT both sides pre-laminate board confirming to IS-14587:1998.The height of modesty shall be 450 mm.The modesty panel will be connected to the main table by 2 nos special Aluminum extruded brackets. The modesty will be fixed 150 mm from the edge of the table. • Cable management: The table will be provided with suitable grommet hole. Legs and Supports:- The MS supports are made of 55 x55mm diamond shape loop leg ERW tubes- 16g with levelers to cater for floor undulations- +/- 20 mm. ERW Tube confirming to IS 4923 : 1997 – 16g. Main leg members will be connected through a horizontal member size 1.6mm thk, 60x40 cold formed ERW tube confirming to IS 4923: 1997. The vertical and the horizontal tubes will be welded with CO2 MIG welding process confirming to IS 816 and ISO 9692-2. The leg will be fabricated using Argon & Co2 gas mixture on a Robotic welding machine to ensure adequate welding strength with consistency.• The legs will be connected with Cross beams to take care of the bending stress catering up to 1800 mm length and up to 900 mm depth of the work surface. Finish:- All metal components & aluminum die cast parts will be powder coated by Nano ceramic surface treatment process compiled to a Bend test-ASTM D3451 – 06, Adhesion -DIN EN 14901 Salt spray test- DIN EN ISO 9227, which is non-hazardous, environmental friendly and will have uniform powder coating thickness of 50-60-micron thickness.Wire Management: 61 LINEAR WORKSTATIONSSIZE:- 1350W X 600D X 750HT AND 300HT HEIGHTSpecifications: Table Top - 25mm thick Pre Lam particle board with 2mm edge lipping on all exposed sides. Support - MS powder coated diamond shape leg of 55X55mm size with die cast connectors and supporting MS cross beams. Main Screen:- Aluminum anodised 30mm scree n with fabric magnetic and glass marker tiles. Privacy Screen:- 6mm thick acrylic screen on studs. Wiremanagement - 450mm metal flip up with provision to mount switches and sockets on MS cable tray and vertical wire entry cover between the intermeidate leg for power and data. 62 DUSCUSSION TABLE SIZE:- 1050DIA X 750HTSpecifications Table Top: 25mm thick Pre laminate particle board with 2mm PVC edge lipping on all exposed edges (Straight/Reverse waterfall edge) Support End Legs: Enrich Leg Intermediate Legs: MS podwer coated 60X40mm legs and supporting ms cross beams Wire Management:Continuous PVC Cable Tray with provision to mount switches and sockets as per client requirement. , Vertical wire entry cover for wire uptake from floor to cable tray and 450mm Aluminium Flip Up for swicth access.Make-Featherlite/Geeken/Hof/Equivalent 63 DISCUSSION TABLE SIZE:- 2400W X 1050D X 750HTSpecifications Table Top: 25mm thick Pre laminate particle board with 2mm PVC edge lipping on all exposed edges Support: End Legs: MS powder coated legs Intermediate Legs: MS podwer coated 60X40mm legs and supporting MS cross beams (40X20mm) Wire Management: Continuous PVC Cable Tray with provision to mount switches and sockets as per client requirement. Vertical wire entry cover for wire uptake from floor to cable tray and 450mm Aluminium Flip Up for swicth access. MODEL:-ENRICH,Make-Featherlite/Geeken/Hof/Equivalent 64 High Back Chairs Seat and back is made out of 12mm molded hot pressed plywood in ergonomic shape fitted with Imported T-nuts and revited in to the wood.Gaslift - Class 4 tested -ANSI BIFMA performance standards.Castors - Twin Castors 50mm dia castors compling to ANSI / BIFMA X 5.1 – 2002.The 640mm dia (26 inches) five pronged base is made out of GF nylon – Reinforced with bottom ribbing for additional buttress and strength.Tested prudently and rigorously as per ANSI/BIFMA X5.1-2011 General Purpose Office Chair Standards.Upholstery: Seat Cushion with pre moulded foam having leatherette tapestery of 50 - 60 density Density -- 52 kg/m3 Hardness -- 12.6kgf at 25%.Distinctively and characteristically designed tilt mechanism offering a very smooth and fluidic reclining motion with tension adjust knob and importantly offering seat to back recline ratio of 3:7, optimal for good back support.Multilock mechanism is fabricated from CR Sheets, undergo through CO2 welding process imparting uniform surface finish and tensile strength. The components are processed with high degree of precision and care so as to assemble with other parts in perfect harmony to give smooth and effortless reclining experience. Tension springs are made out Grade II material conforming to Indian Standards. Also provided with release levers for locking mechanism and height adjustment of seat. Mechanism aides to operate the height adjustment, and has been equipped with 3 locking positions, back rest “ Return Prevention” function. Back Frame is inserted with leathertte tapestery cushion & Adjustable Lumbar Support.Tension control is below the Seat.Moulded polyurethene Arms confirming to IS 7078 with steel inserts for long Moulded self skinned polyurethene Arms confirming to IS 7078 with steel insets for long life. one way adjustable - Height Adjustable.Seat is duly upholstered with approved fabric. Chair will have adjustable headrestChair Should be BIFMA Certified.Seat: Depth- 51.5 cm Width- 44.5 cm Dimensions: Width- 51.5 cm Depth- 53.5 cm Minimum Height- 99.5 cm Maximum Height- 108.5 cm Minimum Seat Height- 44.5 cm Maximum Seat Height- 52.5 cm Width (Arm to Arm)- 66 MODEL, Chair should be BIFMA and Green Guard certified.:- AMAZE HB, Make-Featherlite/Geeken Equivalent. 65 Medium Back Chairs Seat and back is made out of 12mm molded hot pressed plywood in ergonomic shape fitted with Imported T-nuts and revited in to the wood.Gaslift - Class 4 tested -ANSI BIFMA performance standards.Castors - Twin Castors 50mm dia castors compling to ANSI / BIFMA X 5.1 – 2002.The 640mm dia (26 inches) five pronged base is made out of GF nylon – Reinforced with bottom ribbing for additional buttress and strength.Tested prudently and rigorously as per ANSI/BIFMA X5.1-2011 General Purpose Office Chair Standards.Upholstery:Seat Cushion with pre moulded foam having leatherette tapestery of 50 - 60 density Density -- 52 kg/m3 Hardness -- 12.6kgf at 25%.Distinctively and characteristically designed tilt mechanism offering a very smooth and fluidic reclining motion with tension adjust knob and importantly offering seat to back recline ratio of 3:7, optimal for good back support.Multilock mechanism is fabricated from CR Sheets, undergo through CO2 welding process imparting uniform surface finish and tensile strength. The components are processed with high degree of precision and care so as to assemble with other parts in perfect harmony to give smooth and effortless reclining experience. Tension springs are made out Grade II material conforming to Indian Standards. Also provided with release levers for locking mechanism and height adjustment of seat. Mechanism aides to operate the height adjustment, and has been equipped with 3 locking positions, back rest “ Return Prevention” function. Back Frame is inserted with leathertte tapestery cushion & Adjustable Lumbar Support.Tension control isbelow the Seat.Moulded polyurethene Arms confirming to IS 7078 with steel inserts for long Moulded self skinned polyurethene Arms confirming to IS 7078 with steel insets for long life. one way adjustable - Height Adjustable.Seat is duly upholstered with approved fabric. Chair Should be BIFMA Certified.Seat: Depth- 51.5 cm Width- 44.5 cm Dimensions: Width- 51.5 cm Depth- 53.5 cm Minimum Height- 99.5 cm Maximum Height- 108.5 cm Minimum Seat Height- 44.5 cm Maximum Seat Height- 52.5 cm Width (Arm to Arm)- 66 cm Arm Rest Height- 18- 27.5 cm Chair should be BIFMA and Green Guard certified. AMAZE MB, Make-Featherlite/Geeken Equivalent. 66 Medium Back chair Having Base: Nylon Base- The 640mm dia (26 inches) five pronged base is made out of GF nylon – Reinforced with bottom ribbing for additional buttress and strength. Tested prudently and confirming to ANSI/BIFMA X5.1-2011 General Purpose Office Chair Standards. The base shall be 67 cm pitch-center diameter -77 cm with castors. MS ring will be insert molded for better grip in the swaged taper. Castors: Twin Castors 50mm dia complying to ANSI / BIFMA X 5.1 – 2002. Castors will be made in PP.The axle pin will be rust protected- Zinc pacified. The pin should be designed to have push fit with lock ring. RoHS compliant castors. Gas lift: Standard Gas lift 100 mm stroke with pneumatic height adjustment as per the seat height criteria.- Class 4 as per ANSI BIFMA performance standards. Possibility to increase the seat height if required with Gas lift stroke- 110 -125 mm. Mechanism:Centre Tilt Mechanism:compact and stable with 8″ x 6″ mount holes as per European Standard. Initial seat angle of 3 degrees and full recline angle of 20 degrees for ergonomic comfort. Provided with common leverfor locking and up/down adjustment and horizontal movement of the lever to engage and disengage lock at upright positionLever provided for rotational movementto operate gas lift and adjust chair height to user specification. Full length plastic knob provided to cover lever bar giving better aesthetical appeal to the mechanism. Knob provided to adjust spring tension to suit individual user in order to ensure maximum chair comfort. Arms:Fixed Arms Injected molded arms- polyurethane 20% GF nylon. The polypropylene arms will have steel inserts. The arm profile should blend with the back profile without gap. Seat: Seat Height- 450-540mm with hydraulic height adjustability of 90-100mm. Seat Width & Height- Size of the chair shall be -Back: 45.0cm. (w) x 59.0cm.(H) .Seat: 48.0cm (w) X 49.0cm.(D). Chair back should be connected to the Polyurethane arms for achieving comfortable seating posture.Effective back height from Seat - 560mm, Ply wood- 12 mm thick with 7 ply. Fire retardant type exterior grade phenol formaldehyde bonded. It will be hot pressed ply - conforming to I.S.I. 5509. The arm and back shall be fixed together to the seat with Allen bolts.The bolts will be screwed to the “T” nuts fixed to the plywood seat.Fabric: Upholstery:Seat & Back are duly upholstered with approved fabric. The back should have the option of mesh back AN-70 (black) and AN-75(grey). GSM for mesh 340. No flaming or progressive smolderingwithin one hour of placement of the cigarettes. Fire rated fabric confirming to BSEN 1021 and IS 15061-2012 Foam: Seat cushion with pre molded foam of 50 - 60 density in the shape of plywood.Density -- 52 kg/m3, Hardness -- 12.6kgf at 25%- Back cushion- density- 32g/sq in. Back:Mesh back on injected molded PP with 30% GF nylon. The back should have the option of mesh or fabric back. The mesh will be GSM 340 grade. . ALPHA MB, Make-Featherlite/Geeken Equivalent. 67 Single Seater Sofa of Size: 875 (W) x 750 (D) X 820 (H) Seat Foam: the sofa is made up of fine quality leatherette.The structure is made up of silver wood and pine wood.The Seat is made of PU Foam with Density 32 to 40 +/- 2 kg/cu .mtr Seat is upholstered wuth Leatherite.Back Foam: The Back is made of PU Foam with Density 32 to 40 +/- 2 kg/cu, Backis upholstered withLeatherite.Unterstructure is made up of silver wood or pine wood , 4mm Dia zigzag Spring is mounted in the understructure for support and additional cushioning purpose. Legs should be made up of stainless steel tubes/pipes., CONVERSE, Make-Featherlite/Geeken Equivalent. 68 Two Seater Sofa of Size:1320 (W) x 750 (D) X 820 (H) Seat Foam: the sofa is made up of fine quality leatherette.The structure is made up of silver wood and pine wood.The Seat is made of PU Foam with Density 32 to 40 +/- 2 kg/cu .mtr Seat is upholstered wuth Leatherite.Back Foam: The Back is made of PU Foam with Density 32 to 40 +/- 2 kg/cu, Backis upholstered with Leatherite.Unterstructure is made up of silver wood or pine wood , 4mm Dia zigzag Spring is mounted in the understructure for support and additional cushioning purpose. Legs should be made up of stainless steel tubes/pipes., CONVERSE,Make-Featherlite/Geeken/Hof/Equivalent 69 Corner Table ofSIZE:- 550W X 550D X 400D Table top made out of stoneBase/ Understructure:- Made up of MSand will be powder coated by Nano ceramic surface treatment process compiled to a Bend test-ASTM D3451 – 06, Adhesion -DIN EN 14901 Salt spray test- DIN EN ISO 9227, which is non-hazardous, environmental friendly and will have uniform powder coating thickness of 50-60-micron thickness, CT-867, Make-Featherlite/Geeken Equivalent. 70 Side Storage of Size 900Wx450Dx1200HT will be made in 18 MM PLB (Pre laminated board) with the density of 680kg/m³ and 18 mm thick one side pre-laminate board confirming to IS 12406 : 2013. Surface: CPL ( continuous pressure laminate) in 0.5mm thickness in melamine finish. The PLB will be confirming to E-1 Grade as per the JIS A 5905-2003 standards and approved shade confirming to IS-12823:1990.The back of storage will be made in 9 MM PLB (Pre laminated board) with the density of 680kg/m³ and 18 mm thick one side pre-laminate board confirming to IS 12406 : 2013. Surface: CPL ( continuous pressure laminate) in 0.5mm thickness in melamine finish. Storgage will be provided with edge banding 2 mm thick PVC edge band will confirm to DIN 68861 for resistance to clearers. The Hot melt glue used for fixing the PVC edge band should have ISO 9001- 2015 quality certification and confirm to ASTM D 4499 standards for viscosity and thermal stability. The edge band material should have Shore D hardness of 79± 4. storage will have two adjustable shelves making 3 compartments.The shutters are fitted with auto closing hinges.Central locking system , levellers & other necessary hardware are priovided.Handles will be hand grooved, Make-Featherlite/Geeken Equivalent. 71 Side Storage of Size 900Wx450Dx750HT will be made in 18 MM PLB (Pre laminated board) with the density of 680kg/m³ and 18 mm thick one side pre-laminate board confirming to IS 12406 : 2013. Surface: CPL ( continuous pressure laminate) in 0.5mm thickness in melamine finish. The PLB will be confirming to E-1 Grade as per the JIS A 5905-2003 standards and approved shade confirming to IS-12823:1990.The back of storage will be made in 9 MM PLB (Pre laminated board) with the density of 680kg/m³ and 18 mm thick one side pre-laminate board confirming to IS 12406 : 2013. Surface: CPL ( continuous pressure laminate) in 0.5mm thickness in melamine finish. Storgage will be provided with edge banding 2 mm thick PVC edge band will confirm to DIN 68861 for resistance to clearers. The Hot melt glue used for fixing the PVC edge band should have ISO 9001- 2015 quality certification and confirm to ASTM D 4499 standards for viscosity and thermal stability. The edge band material should have Shore D hardness of 79± 4. storage will have two adjustable shelves making 3 compartments.The shutters are fitted with auto closing hinges.Central locking system , levellers & other necessary hardware are priovided.Handles will be hand grooved, Make-Featherlite/Geeken Equivalent. 72 Side Storage of Size 1200Wx450Dx750HT will be made in 18 MM PLB (Pre laminated board) with the density of 680kg/m³ and 18 mm thick one side pre-laminate board confirming to IS 12406 : 2013. Surface: CPL ( continuous pressure laminate) in 0.5mm thickness in melamine finish. The PLB will be confirming to E-1 Grade as per the JIS A 5905-2003 standards and approved shade confirming to IS-12823:1990.The back of storage will be made in 9 MM PLB (Pre laminated board) with the density of 680kg/m³ and 18 mm thick one side pre-laminate board confirming to IS 12406 : 2013. Surface: CPL ( continuous pressure laminate) in 0.5mm thickness in melamine finish. Storgage will be provided with edge banding 2 mm thick PVC edge band will confirm to DIN 68861 for resistance to clearers. The Hot melt glue used for fixing the PVC edge band should have ISO 9001- 2015 quality certification and confirm to ASTM D 4499 standards for viscosity and thermal stability. The edge band material should have Shore D hardness of 79± 4. storage will have two adjustable shelves making 3 compartments.The shutters are fitted with auto closing hinges.Central locking system , levellers & other necessary hardware are priovided.Handles will be hand grooved, Make-Featherlite/Geeken Equivalent. 73 Storage With Planter of Size 750W x 450D x 1050+150HT With storage will be made in 18 MM PLB (Pre laminated board) with the density of 680kg/m³ and 18 mm thick one side pre-laminate board confirming to IS 12406 : 2013. Surface: CPL ( continuous pressure laminate) in 0.5mm thickness in melamine finish. The PLB will be confirming to E-1 Grade as per the JIS A 5905-2003 standards and approved shade confirming to IS-12823:1990.The back of storage will be made in 9 MM PLB (Pre laminated board) with the density of 680kg/m³ and 18 mm thick one side pre-laminate board confirming to IS 12406 : 2013. Surface: CPL ( continuous pressure laminate) in 0.5mm thickness in melamine finish. Storgage will be provided with edge banding 2 mm thick PVC edge band will confirm to DIN 68861 for resistance to clearers. The Hot melt glue used for fixing the PVC edge band should have ISO 9001- 2015 quality certification and confirm to ASTM D 4499 standards for viscosity and thermal stability. The edge band material should have Shore D hardness of 79± 4. storage will have two adjustable shelves making 3 compartments.The shutters are fitted with auto closing hinges.Central locking system , levellers & other necessary hardware are priovided.Handles will be hand grooved, Make-Featherlite/Geeken Equivalent. 74 Storage With Planterof Size 900W x 450D x 1050+150HT With storage will be made in 18 MM PLB (Pre laminated board) with the density of 680kg/m³ and 18 mm thick one side pre-laminate board confirming to IS 12406 : 2013. Surface: CPL ( continuous pressure laminate) in 0.5mm thickness in melamine finish. The PLB will be confirming to E-1 Grade as per the JIS A 5905-2003 standards and approved shade confirming to IS-12823:1990.The back of storage will be made in 9 MM PLB (Pre laminated board) with the density of 680kg/m³ and 18 mm thick one side pre-laminate board confirming to IS 12406 : 2013. Surface: CPL ( continuous pressure laminate) in 0.5mm thickness in melamine finish. Storgage will be provided with edge banding 2 mm thick PVC edge band will confirm to DIN 68861 for resistance to clearers. The Hot melt glue used for fixing the PVC edge band should have ISO 9001- 2015 quality certification and confirm to ASTM D 4499 standards for viscosity and thermal stability. The edge band material should have Shore D hardness of 79± 4. storage will have two adjustable shelves making 3 compartments.The shutters are fitted with auto closing hinges.Central locking system , levellers & other necessary hardware are priovided.Handles will be hand grooved, Make-Featherlite/Geeken Equivalent. 75 Printer Table With Storageof Size 900W x 600D x 750HT With storage will be made in 18 MM PLB (Pre laminated board) with the density of 680kg/m³ and 18 mm thick one side pre-laminate board confirming to IS 12406 : 2013. Surface: CPL ( continuous pressure laminate) in 0.5mm thickness in melamine finish. The PLB will be confirming to E-1 Grade as per the JIS A 5905-2003 standards and approved shade confirming to IS-12823:1990.The back of storage will be made in 9 MM PLB (Pre laminated board) with the density of 680kg/m³ and 18 mm thick one side pre-laminate board confirming to IS 12406 : 2013. Surface: CPL ( continuous pressure laminate) in 0.5mm thickness in melamine finish. Storgage will be provided with edge banding 2 mm thick PVC edge band will confirm to DIN 68861 for resistance to clearers. The Hot melt glue used for fixing the PVC edge band should have ISO 9001- 2015 quality certification and confirm to ASTM D 4499 standards for viscosity and thermal stability. The edge band material should have Shore D hardness of 79± 4. storage will have two adjustable shelves making 3 compartments.The shutters are fitted with auto closing hinges.Central locking system , levellers & other necessary hardware are priovided.Handles will be hand grooved, Make-Featherlite/Geeken Equivalent. 76 Steel almirah for office purpose in perfectly upright and straight position. The overall size of the almirah shall be 900mm (W) X 450mm (D) X 2015mm (H) including legs. It should be supplied with 4 nos. of adjustable shelves i.e. 5 loading compartments. Each compartment shall be 400 mm high. Door shall be made of 1mm thick and all other components shall be made of 0.8mm thick high yield strength CRCA sheet of grade ‘D’ confirming to IS: 513. Proper stiffeners shall be provided in shelf & door. The steel hinged door shall be provided with lever handle & 3 way locking mechanism with 6 lever lock with Key. The shelves shall have folded constructions which have intrinsic rigidity and high load carrying capacity.Uniformly distributed load capacity per each shelf shall be 40kg maximum. Metal Part should be pre treated with Iron Phosphating with powder coating of 60-80mm thickness, Make-Featherlite/Geeken Equivalent. 77 Electrical Work 78 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group A 79 Supply and fixing of Power point and Supply and fixing of power plug with 10 Amp./250 volt flush type modular switch and 5 pin 10A /250 volt flush type universal modular socket switch on concealed M.S. box including supply of all material, labour t&P etc. required for proper completion of work. 80 Supply and fixing of wire, Power point and Supply and fixing of power plug with 20 Amp./250 volt flush type modular switch and 5 pin 20 nA/250 volt flush typ[e universal modular socket switch on concealed M.S. box including supply of all material, labour t&P etc. required for proper completion of work. 81 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 82 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 83 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 4.0 sq. mm + 1 X 4.0 sq. mm earth wire 84 Supplying & Drawing co-axial TV cable RG-6 grade, 0.7 mm. solidcopper conductor, PE insulated] shielded with fine finned copper braid and protected with PVC sheath in the existing surface/ recessed steel/PVC conduit as required. For T.V. Socket outlet 85 Supply & Fixing of following sizes of medium class PVC conduit alongwith accessories in sueface/recess including cutting the wall & making it good the same in case of recessed conduit as required. 20MM 86 Supply & Fixing of following sizes of medium class PVC conduit alongwith accessories in sueface/recess including cutting the wall & making it good the same in case of recessed conduit as required. 25MM 87 Supply & Fixing of following sizes of medium class PVC conduit alongwith accessories in sueface/recess including cutting the wall & making it good the same in case of recessed conduit as required. 32MM 88 Supply and fixing of recess mounting round15 TO 18 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. CAT-AAA 89 Supply and fixing of 36 Watt to 46 Watt above 3300 leumin indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing body with extended heat sink and diffuser of Special Polycarbonate meterial and driver set complete in all respect. CAT-AAA 90 Supplying & fixing of TV Antenna socket on Modular Plate & G.I Box including connections 91 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required, 1 or 2 Module 92 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required, 3 Module 93 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required, 4 Module 94 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required, 6 Module 95 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required, 8 Module 96 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required, 12 Module 97 Blank plate for modular plate type switch boards wherever required. 98 Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 25 Sqmm 3.5 core 99 Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 35 Sqmm 3.5 core 100 Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 70 Sqmm 3.5 core 101 Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer- Incharge. 25 sq. mm 3-1/2 core 102 Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer- Incharge. 35 sq. mm 3-1/2 core 103 Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer- Incharge. 70 sq. mm 3-1/2 core 104 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge. 25 sq. mm 105 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge. 35 sq. mm 106 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge. 70 sq. mm 107 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 108 S&F of 100 Amp 4 pole MCCB (25 KA) Thermal Magnetic release 109 S&F of 125 Amp 4 pole MCCB (25 KA) Thermal Magnetic release 110 S & F surface/Flush mounting 6ways VTPN distribution board with additional metal door without MCB complete in all respect,as directed at site by Engineer in charge. 111 S & F surface/Flush mounting 8ways VTPN distribution board with additional metal door without MCB complete in all respect,as directed at site by Engineer in charge. 112 S & F surface/Flush mounting 12ways V TPN distribution board with additional metal door without MCB complete in all respect, as directed at site by Engineer in charge. CAT-A 113 Providing Drawing Connecting And Testing Of Enhanced Categoey 4 Pair Lan Local Area Network Cable 24 AWG Conductor Performance Specifide 5E U L and CUL Listed In Existing PVC Conduit .(CAT-6 Network Cable) 114 Supply & Fixing of LED Profile Light all complete as per drawing and specification and direction of engineer incharge. Make-Ledadvance/Ledos/Ledlum/Philips, Equivalent 115 Supply & Fixing of LED Profile Light Driver all complete as per drawing and specification and direction of engineer incharge. Make-Ledadvance/Ledos/Ledlum/Philips, Equivalent 116 Supply and fixing of 400mm Wall Fan all complete as per drawing and specification and direction of engineer incharge. Make-Crompton/Bajaj/Havels Equivalent 117 Supply and fixing of 250mm Fresh Air Fan all complete as per drawing and specification and direction of engineer incharge. Make-Crompton/Bajaj/Havels Equivalent 118 Supply and Fixing of Deep Recess Mounting round 10 Watt COB LED Spot Light having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. Make-Ledadvance/Ledos/Ledlum/Philips, Equivalent 119 Supply & Fixing of Hanging Light all complete as per drawing and specification and direction of engineer incharge. Make-Ledadvance/Ledos/Ledlum/Philips, Equivalent 120 Providing & Fixing of Modular plate type white RJ 45 CAT 6 Data/Talephone outlet / information outlets ETL verified to meet or exceed TIA / EIA category 6 requirements, universal wiring label permitting to either T568A or T568B, UL listed,for computer networkingcomplete in all respect with cover plate, grid plate, screws, MS box, etc with connections as required with 2nos RJ-45 Data outlet 121 Supply of 250 KVA Three Phase 415 V silent DG Set comprising of CUMMINS engine model qsb6.7g17 coupled to STAMFORD make 250 KVA Three Phase 415 V alternator both mounted on common base frame alongwith fuel tank, Manual panel, battery with lead, AVM Pads, Residential Silencer etc. which will be mounted on a reinforced steel base frame, the DG set is securely anchored to a strong concrete base engineered for specific site conditions and load requirements. The base frame features isolation mounts or pads for vibration dampening, ensuring smooth and quiet operation. and the price including loading & un-loading and installation and conections. 122 Supplying, Installation, Testing and commissioning of dust, damp and vermin proof cubicle free floor, indoor type factory built sheet steel enclosed modular bolted construction extendable type LT CUM AMF Panel, suitable for operation on 415 ±10%volts, 50 Hz AC 3 phase 4 wire supply system fabricated out of suitable sized square tubular section andcoveredwith CRCA sheet steel of 2mm thick for frame work and 1.6mm covers (non load bearing), 2mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having extensible type TPNAluminium bus bars of high conductivity, SMC bus bar supports, with bottom base channel of section not less than ISMC 75mm, fabrication shall be done in transportable sections, entire panel shall have a common G.I. earth bus bar to switch gears with required size of Alum. bus bars and inter-connectionwith solid copper conductor wires / aluminium strips, neutral links, including control wiring with 1.5 / 2.5sqmm. PVC insulated FRLS copper conductor Single Core cable, cable alleys, cable gland plates in two half, etc. necessary metering protections & indications and mounted with the following switch gears as per drawingandtechnical specifications etc. 123 Supplying, Installation, Testing and commissioning of dust, damp and vermin proof cubicle free floor, indoor type factory built sheet steel enclosed modular bolted construction APFC Panel, fabricated out of suitable sized square tubular section andcoveredwith CRCA sheet steel of 1.6mm thick for frame work and 1.6mm covers (non load bearing), 2mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade. 124 LTDB 125 Supplying, Installation, Testing and commissioning of dust, damp and vermin proof cubicle free floor, indoor type factory built sheet steel enclosed modular bolted construction LTDB, fabricated out of suitable sized square tubular section andcoveredwith CRCA sheet steel of 1.6mm thick for Enclosure, 2mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade. 126 CABLES 127 Supply and laying of aluminium conductor PVCinsulated armoured served sheathed cables 1100 Voltsgrade at a depth of 750 mm below ground level over acushion of 75 mm. thick sand all around and protectedwith burnt bricks on sides and on top. On surface the cablerun shall be fixed on M.S. clamps etc. of suitable size oras directed by the Engineer-Incharge, complete in allrespect. The armouring of the cable shall be properlyconnected with the earth conductor by clamps etc.. 185 sq. mm 3-1/2 core 128 Supply of 2.5SQMM 4 core copper flexible cable 129 Supply of 50SQMM 1 core copper flexible cable 130 END TERMINATION 131 185Sqmm End termination with materials 132 EARTHING 133 GI Earthing 134 Copper Earthing 135 Supply & Laying of 25X3 GI strip with nut bolt & washers 136 LABOUR CHARGE 137 FIRE DETECTION AND ALARM SYSTEM 138 supplying , installation , Testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required. 139 supplying , installation , Testing & commissioning of manual call boxes of MS construction in surface/recess with strainless steel chain & hammer assembly complete with glass and push button etc. as required. 140 supplying , installation , Testing & commissionin response indicator on surface/recess Ms box having two LEDs mettallic cover complete with all connections etc. as required. 141 supplying , installation , Testing & commissionin fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching trasformer etc. complete as required. 142 supplying , installation , Testing & commissioning of main controland indicating panel made out of 16 SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement , audio and visual indication for fire alarm and public adress system, monitoring system including connections, interconnections etc complete as required. 10 zone panel for fire alarm system 250 Watt amplifier racks suitable for operation on 230V AC/24V DC supply conforming to IEC-268-3 complete with all accessories as required-2 Nos. ( one to act asstanby) Talk back master stationwith LED PTT ( press to talk ) push button for operation on 230V AC/24 V DC supply conforming to IEC-268 for simplex mode of operation/ communication suitable for 20 Nos. talk back unit-1 set. Anouncement control desk suitable for selection of different zones selectively and on ALL CALL switch with visual indication etc. complete as required -1 set Amplifier change over switch for inter changing amplifier -1 No. Monitor panel for loudspeaker complete with output selector, ON/OFF switch, fuse, visual indications etc. complete as required-1 NO. Gooseneck microphone with stand and ON/OFF switch -1 N0. Main ON/OFF switch, fuse indication lamps, DC and AC voltmeter & ammeters , terminal blocks etc. complete as required-1 set Battery charger trickle cum boost to talk complete load of fire alarm PA system complete with all accessories including providing & fixing of 2 nos. 12 volt, 60 AH each sealed maintenanance free batteries-1 set. 143 supplying , installation , Testing & commissionin of main control and indicating panel made out of 16 SWG MS sheet to accommodete the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public adress system, monitoring system including connections, interconnections etc complete as required. 6 zone panel for fire alarm system 100 watt amplifier racks suitable for operation on 230V AC/24V DC supply conforming to IEC-268-3 complete with all talk back master station with LED PTT ( press to talk ) push buttonfor operation on 230V AC/24 V DC supply conforming to IEC-268 for simplex mode of operation/ communication suitable for 20 Nos. talk back unit-1 set. annoucement control desk suitable for selection of different zones selectively and ON ALL CALL switch with visual indication etc, complete as required-1 set Amplifier change over switch for inter changing amplifier-1 No. Monitor panel for loudspeaker complete output selector ON/OFF switch, fuse visual indications etc. complete as required -1 No. Gooseneck microphone with stand and ON/OFF switch-1 No. Mains ON/OFF switch, fuse indication lamps, DC and AC voltmeters & ammeters terminal blocks etc. complete as required-1 set. Battery charger trickle cum boost to take complete load of fire alarm PA system complete with all accessories including providing & fixing of 2 nos. 12 volt, 30 AH each sealed mainenance free batteries-1 set. 144 supplying , installation , Testing & commissioning of fire fighter telephone handset complete as required. 145 PUBLIC ADDRESS SYSTEM 146 supplying , installation , Testing & commissioning of 6 zone, voice alarm controller with USB, MP3 playaer ( including 6 zone button paging station ) with seamless intergration facility with main fire alarm panel for voice evacuation complete as required. 147 supplying , installation , Testing & commissioning of 1.5/3/6Wceiling/wall speakers complete as required. 148 CABLING & WIRING 149 supplying & laying of 2* 1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. 150 supplying & drawing of cable fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steelconduit of following pairs, cores and size including connections and interconnections etc. as required speaker cable Two pair, 2-core , 1.5 sqmm 151 Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required 152 Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 153 Supply and fixing of fire extinguisher, ABC Type 4.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 154 Supply, Installation testing and commissioning of Ceiling mounted automatic fire extinguisher (Dry Chemical powder) of 10KG capacity including all fitting and accessories as per dwg and spec as complete required. 155 Supply,Installation, Testing & Commissioning of 3 Nos. G.I. sand buckets painted Red Color complete with suitable size G.I. stand duly painted Red Color of suitable size to hang 3 Buckets at a time as per required specifications. 156 CCTV SURVELLANCE SYSTEM 157 Supply, Installation, Testing and Commissioning of fixed Camers, 2 MP, 1/2.7 CMOS image sensor, low illuminance 2 MP (1920 x 1080) @ 25/30 FPS Output H 265 codec, IR LED 30m, DWDR, 3D NR HLX BLC digital watermarking, Abnormally detection: Motion detection, video tampering, 12 V DC/PoE power supply Network TDN IR Indoor/Outdoor complete 158 Supply, Installation, Testing and Commissioning of 32 channel NVR with Embedded enterprises grade linux processor, rel time time H.265 Security baseline 2.1, 1080p@30 fps adaptive decoding, ONVIF and RTSP protocols, resolution HDMI 4K, AI Face detection, perimeter protection, IVS, people counting, heat map, and SMD, BW 160 Mbps, Audio PCM/G711A/G726/ AAC, privacy masking, video loss, scene changing, PIR alarm, SATA III port up to 10 TB. Make Dahua/HikVision 159 Supply, Installation, testing and commissioning of 6TB SATA Internal with 1M hours MTBF, 180 TB workload rate, write-intensive, low bit-rate, high stream-count, prioritized write-op. Make - WD/Seagate 160 Supply, Installation, testing and commissioning of HDBaseT Hdmi Extender Make - Milestone 161 Supply, Installation, testing and commissioning of wall mountable 55 high resolution LED monitor with HDMI port and commercial series suitable for 12x7 operation. All accessories for installation including wall mounting stand/ bracket. Make - Samsung/Sony 162 TOILET WORK 163 Providing and fixing of Soap Dispenser as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent 164 Supply&Fixingofwindowsmadefrommulti chambered UPVC profiles of minimum 60/108 mm thicknessof (Wintechmakeorequivalent)in natural from stailized for heat, light, impact & UV radiation. The UPVC profiles should be reinforced withgalzvanizedsteelprofilesofdesigned thickness.Floatglassofapprovedcolourin 4/5/6/8 mm or as desired by the costumer shall be fixed with heveled beads. All openable / sliding sashes shall be having grey/black colored weather seal fitted in continuous lenghts made from bubble PTV Rubber & side Hung with 90L openin friction syats of rust proof stainless steel with provision of multipoint lockng system (casement only) made from Espag rods (coated steel) all handle shall be made from die Cast zinc alloy in white finish only as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. 165 Providing & Fixing of Translucent Zebra Blinds with Hand Rail of approved shade as per drawing & specificationas approved by Engineer -in-Charge. 166 Providing, fabricating & placing single leaf single swing aluminium stile door with 12mm thick toughened glass & stile size of 40mm x 90mm. The door frame of size 70 x 50mm shall be formed with heavy duty aluminium door, fixed to dry wall partition. Rate to include providing & fixing of Geze make standard stainless steel brush finished hardwares Hinges: flush door hinge -Geze-. Finis: Std finish Handle & lock: lever handle & Mortise lock set with both side key cylinder- Geze, Door Closer: Exposed door closer TS 3000V - Asymatric Rack and Pinion Door Closer with hold-open slide arm Closing force: 1-4 (adjustable) Tested according to EN 1154 for door width upto: 1100mm Door stopper: Half moon door stop Finish of profile- Black finish System - Micra I door Make - Liko-s 167 Providing & Fixing of Photo Frames Having Size (500WX650HT) of Invest UP in Coloured Canvas Printswith wooden frame borders & glasscomplete as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. 168 Providing & Fixing of Photo Frames Having Size (700WX400HT) of Invest UP in Coloured Canvas Printswith wooden frame borders & glasscomplete as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. 169 Providing & Fixing of Photo Frames Having Size (650WX650HT) of Invest UP in Coloured Canvas Printswith wooden frame borders & glasscomplete as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. 170 Providing & Fixing of Photo Frames Having Size (1175WX650HT) of Invest UP in Coloured Canvas Printswith wooden frame borders & glasscomplete as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. 171 Providing & Fixing of Photo Frames Having Size (1250WX775HT) of Invest UP in Coloured Canvas Printswith wooden frame borders & glasscomplete as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. 172 Providing & Fixing of Round Shape Polmer Planter of Size (375DIA X 375HT) With Thermocol Packing & Double Layer of Pabbles With Artificial 36Plants of approved shade as per drawing & specificationas approved by Engineer -in-Charge.MR 173 Providing & Fixing of Square Shape Polmer Planter of Size (375Wx375Dx400HT) With Thermocol Packing & Double Layer of Pabbles With Artificial 36Plants of approved shade as per drawing & specificationas approved by Engineer -in-Charge.MR 174 Providing & Fixing of Rectangular Shape Polmer Planter of Size (600Wx325Dx375HT) With Thermocol Packing & Double Layer of Pabbles With Artificial 36Plants of approved shade as per drawing & specificationas approved by Engineer -in-Charge.MR 175 Providing & Fixing of Wooden Planter OF Size (1800L X 600W x 600HT) With Thermocol Packing & Double Layer of Pabbles With 55Nos Artificial Bamboo 60 Plants of approved shade as per drawing & specificationas approved by Engineer -in-Charge.MR 176 Providing & Fixing of Artificial Small Plants Inside Existing Wooden Planter of Size (900L X 450W x 150HT) With Thermocol Packing & Double Layer of Pabbles of approved shade as per drawing & specificationas approved by Engineer -in-Charge.MR 177 Providing & Fixing of Signages of Size (8 x 8) Made of Side Moulded Signages made with Premium Laminate & Acrylic Laser Cut Letters as per deisgn & Multi Layering with Wooden Finish as base of Male, Female Toilet & Pantry, complete as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. 178 Providing & Fixing of Signages of Size (47 x 14) Made of Multi Layered Signage made with 5mm & 3mm Thick Acrylic & UV Prints on Base Acrylic & Acrylic Letters of INVEST UP LOGO, complete as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. 179 ELECTRICAL WORK 180 S&F of 63 Amp. TP MCB (10 KA) C Curve S.I.(1017) 181 S&F of 63 Amp. DP MCB (10 KA) S.I.(1011) 182 S&F surface/flush mounting 8ways SPN distribution board with additional metal door without MCB complete in all respect, as directed by Engineer in charge. S.I.(1024A) 183 S&F of 160 Amp 4 pole MCCB (25 KA) Thermal Magnetic release S.I.(1021E) 184 S&F surface/flush mounting 16ways SPN distribution board with additional metal door without MCB complete in all respect, as directed by Engineer in charge. Make-Legrand MR 185 Supply and Fixing of Deep Recess Mounting round 12.5 Watt COB LED Spot Light having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. Make-Ledos MR 186 Supply & Fixing of 50X70MM Black Body 4000K Customized LED Profile Hanging Light with LED Modules & Inbuilt Driver all complete as per drawing and specification and direction of engineer incharge. Make-Customized MR 187 Supply & Fixing of 150MM Inline Mixflow Fresh Air Fan all complete as per drawing and specification and direction of engineer incharge. Make-Rexton Grand-6 MR 188 Supply & Fixing of 150MM Gravity Grill For Inline Mixflow Fresh Air Fan all complete as per drawing and specification and direction of engineer incharge. Make-Rexton Gravity Grill-6 MR 189 Supply & Fixing of 150MM Air Valve For Inline Mixflow Fresh Air Fan all complete as per drawing and specification and direction of engineer incharge. Make-Rexton CAV-6 MR 190 Providing & Fixing of 13Watt LED Surface COB Light In Black Colour all complete as per drawing and specification and direction of engineer incharge. Make-Ledadvance MR 191 INTERIOR WORK 192 Providing & Fixing of Translucent Zebra Blinds with Hand Rail of approved shade as per drawing & specificationas approved by Engineer -in-Charge. 193 Providing & Fixing of Mat Roman Wooden Chick Blinds with Hand Rail of approved shade as per drawing & specificationas approved by Engineer -in-Charge. 194 Providing, fabricating & placing single leaf single swing aluminium stile door with 12mm thick toughened glass & stile size of 40mm x 90mm. The door frame of size 70 x 50mm shall be formed with heavy duty aluminium door, fixed to dry wall partition. Rate to include providing & fixing of Geze make standard stainless steel brush finished hardwares Hinges: flush door hinge -Geze-. Finis: Std finish Handle & lock: lever handle & Mortise lock set with both side key cylinder- Geze, Door Closer: Exposed door closer TS 3000V - Asymatric Rack and Pinion Door Closer with hold-open slide arm Closing force: 1-4 (adjustable) Tested according to EN 1154 for door width upto: 1100mm Door stopper: Half moon door stop Finish of profile- Black finish System - Micra I door Make - Liko-s 195 Providing & Fixing of Square Shape Polmer Planter of Size (375Wx375Dx400HT) With Thermocol Packing & Double Layer of Pabbles With Artificial 36Plants of approved shade as per drawing & specificationas approved by Engineer -in-Charge.MR 196 Providing & Fixing of Round Shape Polmer Planter of Size (375DIA X 375HT) With Thermocol Packing & Double Layer of Pabbles With Artificial 36Plants of approved shade as per drawing & specificationas approved by Engineer -in-Charge.MR 197 Providing & Fixing of Rectangular Shape Polmer Planter of Size (600Wx325Dx375HT) With Thermocol Packing & Double Layer of Pabbles With Artificial 36Plants of approved shade as per drawing & specificationas approved by Engineer -in-Charge.MR 198 Providing & Fixing of Oval Shape Polmer Planter of Size (325DIA X 500HT) With Thermocol Packing & Double Layer of Pabbles With Artificial 36Plants of approved shade as per drawing & specificationas approved by Engineer -in-Charge.MR 199 Providing & Fixing of Oval Shape Polmer Tower Planter of Size (200DIA X 600HT) With Thermocol Packing & Double Layer of Pabbles With Artificial 36Plants of approved shade as per drawing & specificationas approved by Engineer -in-Charge.MR 200 Providing & Fixing of Oval Shape Ceramic Tower Planter of Size (200DIA X 600HT) With Thermocol Packing & Double Layer of Pabbles With Artificial 60Plants of approved shade as per drawing & specificationas approved by Engineer -in-Charge.MR 201 Providing & Fixing of Artificial Vertical Garden Having Natural Look Like Grass of approved shade as per drawing & specificationas approved by Engineer -in-Charge.MR 202 Providing & Fixing of Photo Frames Having Size (1200WX450HT) of Varanasi Picture in Coloured Canvas Printswith wooden frame borders & Non Reflective glasscomplete as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. 203 Providing & Fixing of Photo Frames Having Size (600WX900HT) of Picture in Coloured Canvas Printswith wooden frame borders & Non Reflective glasscomplete as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. 204 Providing & Fixing of Photo Frames Having Size (1200WX750HT) of Varanasi Picture in Coloured Canvas Printswith wooden frame borders & Non Reflective glasscomplete as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. 205 Providing & Fixing of Photo Frames Having Size (500WX375HT) of Varanasi Picture in Coloured Canvas Printswith wooden frame borders & Non Reflective glasscomplete as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. 206 Providing & Fixing of Photo Frames Having Size (600WX600HT) of Uttar Pradesh Sarkar in Black & White/Coloured Canvas Printswith wooden frame borders & Non Reflective glasscomplete as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. 207 Providing & Fixing of Photo Frames Having Size (650WX650HT) of Uttar Pradesh Sarkar in Black & White/Coloured Canvas Printswith wooden frame borders & Non Reflective glasscomplete as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. 208 Providing & Fixing of Photo Frames Having Size (400WX400HT) of Shri Ram Mandirin Black & White Canvas Printswith wooden frame borders & Non Reflective glasscomplete as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. 209 Providing & Fixing of Photo Frames Having Size (725WX725HT) of Sandwitched Flower in Colour Canvas Printswith wooden frame borders & Non Reflective glasscomplete as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. 210 Providing & Fixing of Photo Frames Having Size (475WX1200HT) of Invest UP in Colour Canvas Printswith wooden frame borders & Non Reflective glasscomplete as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. 211 Providing & Fixing of Photo Frames Having Size (450WX600HT) of Invest UP in Colour Canvas Printswith wooden frame borders & Non Reflective glasscomplete as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. 212 Providing & Fixing of Photo Frames Having Size (400WX600HT) of Invest UP in Colour Canvas Printswith wooden frame borders & Non Reflective glasscomplete as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. 213 Providing & Fixing of Signages of Size (1500 x 188)MM Made of 12mm Corian CNC Cut Letters & Fixed on Existing Wall Surface of INVEST UP, complete as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. 214 Providing & Fixing of Signages of Size (1175 x 350)MM Made of Multi Layered Signage made with 5mm & 3mm Thick Acrylic & UV Prints on Base Acrylic & Acrylic Letters of INVEST UP LOGO, complete as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. 215 Providing & Fixing of Signages of Size (200 x 200)MM Made of Side Moulded Signages made with Premium Laminate & Acrylic Laser Cut Letters as per deisgn & Multi Layering with Wooden Finish as base of Male, Female Toilet & Pantry, complete as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. 216 Providing & Fixing of Signages of Size (450 x 200)MM Made of Side Moulded Signages made with Premium Laminate & Acrylic Laser Cut Letters as per deisgn & Multi Layering with Wooden Finish as base of Conference Hall, complete as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. 217 Providing & Fixing of Signages of Size (2400 x 1200)MM Made of UV Prints on Lacquered Glass with Pre Coat & 3 Layer Prinitng of Invest UP Logo, complete as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. 218 Providing & Fixing of Signages of Size (975 x 700)MM Made of HP Latex Prints on Vinyl duly matt laminated & mounted on 5mm Sunboard of Invest UP Logo, complete as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. 219 Providing & Fixing of Signages of Size (350 x 200)MM Made of 3 Layer Name Plates made with Black Acrylic as base & UV Prints on Clear Acrylic as 2nd Layer & 3rd Layer being Acrylic Letters of IIDC, CEO & ACEO Room, complete as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. 220 Providing & Fixing of Signages of Size (875 x 875)MM Made of 6mm Clear Acrylic Laser Cut with UV Prints from Back Side & Heavy White Ink as base & fixed with Spacers, complete as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. 221 Providing & Fixing of Signages of Size (1200 x 600)MM Made of 3D Embossed Acrylic Letters with Multi Layering made with Acrylic & ACP & UV Prints of Invest UP Logo, complete as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. 222 Providing & Fixing of Signages of Size (600 x 150)MM Made of UV Prints on Clear Acrylic Sheet 3mm Black Acrylic Laser Cut Letters Invest UP, complete as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. 223 Providing & Fixing of Signages of Size (600 x 75)MM Made of UV Prints on Clear Acrylic Sheet 3mm Black Acrylic Laser Cut Letters 2nd, 4rth & 6th Floor, complete as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. 224 Providing & Fixing of Signages of Size (12000 x 2400)MM Made of Temporary MS Frame with Black Back Flex Prints of Invest-UP complete as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. 225 Providing & Fixing of Signages of Size (10200 x 2400)MM Made of MS Structure with Black Back Flex Prints mounted on Water Tank Wall with back MS Supports, complete as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. 226 ELECTRICAL WORK 227 S&F of 63 Amp. TP MCB (10 KA) C Curve S.I.(1017) 228 S&F of 63 Amp. DP MCB (10 KA) S.I.(1011) 229 S&F of 63 Amp 4 pole MCCB (25 KA) Thermal Magnetic release MR 230 Supply & Fixing of 150MM Inline Mixflow Fresh Air Fan all complete as per drawing and specification and direction of engineer incharge. Make-Rexton Grand-6 MR 231 Supply & Fixing of 150MM Gravity Grill For Inline Mixflow Fresh Air Fan all complete as per drawing and specification and direction of engineer incharge. Make-Rexton Gravity Grill-6 MR 232 Supply & Fixing of 150MM Air Valve For Inline Mixflow Fresh Air Fan all complete as per drawing and specification and direction of engineer incharge. Make-Rexton CAV-6 MR 233 Supply & Fixing of 110MM Ceiling Mount Fresh Air Fan all complete as per drawing and specification and direction of engineer incharge. Make-Crompton MR 234 Providing & Fixing of 5KVA Online UPS Having 12V/26AH 15Nos Batteries & Battery Stand all complete as per drawing and specification and direction of engineer incharge. Make-Aeon MR 235 Providing & Fixing of Call Bell Chimes all complete as per drawing and specification and direction of engineer incharge. Make-L&T MR 236 Providing & Fixing of 1800MM Linear Hanging LED Light all complete as per drawing and specification and direction of engineer incharge. Make-Ledlum MR 237 Providing & Fixing of 2400MM Linear Hanging LED Light all complete as per drawing and specification and direction of engineer incharge. Make-Ledlum MR 238 Providing & Fixing of 1200MM Designer Hanging LED Light all complete as per drawing and specification and direction of engineer incharge. Make-Ledlum MR 239 Providing & Fixing of 900MM Dia & 300MM Ht Cloth Hanging Fitted with 10Nos LED Candle Light having 3 Colour Change all complete as per drawing and specification and direction of engineer incharge. Make-Ledadvace MR 240 Providing & Fixing of 9Watt LED Surface COB Light In Black Colour all complete as per drawing and specification and direction of engineer incharge. Make-Ledadvance MR 241 AIR CONDITIONING WORK 242 Supply, Installation, Testing & Commissioning of Hi-Wall Cool Type Unit- 0.80 TR + Cordless Remote, Model-FTHT35TV16X + RHTall complete as per drawing, specification and directionas approved by Engineer -in-Charge. 243 Supply, Installation, Testing & Commissioning of Hi-Wall Hot & Cool Type Unit- 1.0 TR + Cordless Remote, Model-FTHT35TV16X + RHTall complete as per drawing, specification and directionas approved by Engineer -in-Charge. 244 Supply & Fixing of Outdoor Stand all complete as per drawing, specification and directionas approved by Engineer -in-Charge. 245 Supply, Installation, Testing & Commissioning of One Way Cassette Type Unit- 2.08TR + Corded Remote + Refnet, Model FXKQ63AV16all complete as per drawing, specification and directionas approved by Engineer -in-Charge. 246 PA SYSTEM WORK 247 Supply, Installation, testing and commissioning of DSP, studio-grade discrete preamps, 24bit Processor, 4 mic/line inputs with AEC, built-in usb for conferencing. Make - Clearone 248 VIDEO CONFERENCING SYSTEM WORK 249 Supply, Installation, testing and commissioning of professional-grade PTZ camera with 20x optical zoom lens, H.264/H.265 streaming, USB network, RS485 and RS232 interfaces to control and 1080p60 HDMI video Make - Clearone 250 Supply, Installation, testing and commissioning of 2x8 Presentation Switcher HDMI Matrix. Make - Milestone 251 Supply, Installation, testing and commissioning of 1X4 Presentation Switcher HDMI Matrix. Make - Milestone 252 Supply, Installation, testing and commissioning of Ipad Docking Case with charging port accessory for Iport Base Station. Make - Iport 253 Supply, Installation, testing and commissioning of 1X4 USB Hub Matrix. Make - Quantum 254 Supply, Installation, testing and commissioning of TPC-IPAD Controller App License. Make - AMX 255 IP TELEPHONE SYSTEM WORK 256 Supply, Installation, testing and commissioning of Enterprise Portable WiFi sip Phone, Unified Firmware, extended battery. Make - Grandstream 257 TOILET WORK 258 Providing and fixing of Wash Basin With Half Pedestal as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent 259 GST Extra as applicable
Contract Date : Ref. Documents   |   Contract Value : Ref. Documents
BRR : 6703233 Appointment of an Event Management Agency on turnkey basis for Designing, Execution and Management/ Supervision of arrangements, activities and ancillary services for an Event being organized in conjunction with Republic Day Celebrations – 2025 at areas in front of Red Fort, Delhi (Gyan Path and two (2) adjoining lawns); 1 EntranceArchesmadeofmetalframewith fabric print 11mtr (W) x 4.5 mtr (H) duly finished as per design approved by ITDC/ Principal Organizer. 2 Entrance Arches made of metal frame with fabric print 6 mtr (W) x 4.5 mtr (H) duly finished as per design approved by ITDC/ Principal Organizer. 3 Help desk: Delhi Police, CCTV, Medical Room, Fire Control Room, Traffic police etc Waterproof Pagodas measuring 5 mtr x 5 mtr, Covered from all sides and top with lockable door for entry and exit having wooden platform base of 10 cm with new carpet (colour as per our requirement) 4 H/Desk - Octonorm Tables 3 ft x 1 .5ft 5 H/Desk· - Banquet chairs with chair covers 6 H/Desk - Power points 7 H/Desk · Dust bin 8 H/Desk - Facia 9 H/Desk - Adequate lighting (comprising of 3 light fittings of 40 Watt each or compatible LED Light Fittings in each pagoda) 10 Office set up of Concerned Ministries (Ministry of Tourism, Culture, Defence, ASI, Textile, Delhi Police,CPWD,ITDCetc.)Waterproof Pagodas measuring 5 mtr x 5 mtr , Covered from all sides and top with lockable door for entry and exithaving wooden platform base of 10 cm. with new carpet (colour as per our requirement) 11 Office setup - Octonorm Tables 3ft x 1.5ft 12 Office setup - Banquet chairs with chair covers 13 Office setup - Power points 14 Office setup - Dust bin 15 Office setup - Fascia 16 Office setup - Adequate lighting (comprising of 3 light fittings of 40 Watt each or compatible LED Light Fittings in each pagoda) 17 Office set up of Concerned Ministries ( Ministry of Road Transport,NECRT,MoEF&CC,Department of Post, Council of Architect, Ministry of Jal Shakti etc.)Water Proof Pagodas(10mtrx5mtr)Structureeachwith wooden platform base of 10 cm, carpet with each to have 12 light fittings of 40 watts each or compatibleLEDlightfittings,Furniture- OctonormTable3’x1.5’-08Nos,Banquet chairs with chair covers 8 nos, Power Points 08 Nos, Spot lights -15 Nos, Dustbin -02 No, etc. withModularstructureinside.EachModular structure within each theme Pavilion to have Presentable Almirah (all equal size) with lockable facility to be placed in each Central Ministry/ Department Pavilion pagoda and 1 No. fascia. Each Pavilion (10 mtr x 5 mtr ) to have additional average Electricity load of 6 KW for each pavilionincluding Electric load required from 22nd January,2025 for fabrication of stalls) 18 Office setup - Octonorm Tables 3ft x 1.5ft 19 Office setup - Banquet chairs with chair covers 20 Office setup - Power points 21 Office setup - Dust bin 22 Office setup - Fascia 23 Office setup - Adequate lighting (comprising of 3 light fittings of 40 Watt each or compatible LED Light Fittings in each pagoda) 24 Security Items / services - Baggage Scanning Machines(as per requirements of security agencies ) 25 Security Items / services – Door Frame Metal Detector at entry points (as per requirements of security agencies) with footfall counting device 26 Security Items/services -Manpowerfor Frisking, detection, security etc. arrangements by trained and uniformed, presentable security personnel (on shift basis of 12 Hours per day) at identified points and as required: - Male - 125 Nos. per day of event on shift basis in ( Day/Night) 27 Security Items / services - Manpower for Frisking, detection, security etc. arrangements by trained and uniformed, presentable security personnel (on shift basis of 12 Hours per day) at identified points and as required: - Female- 50 Nos per day of eventin Day Shift only 28 Bouncers for Dais / Stage arrangements by trained and uniformed, presentable security personnel (on shift basis of 12 Hours per day) required; - Female 10 Nos per day of the event in day shift only) Men 10 Nos per day of the Event. 29 Security Items / services - Queue managers (ribbonised steel barricading) ( as per requirements of security agencies ) 30 Security Items / services - Security Tower ( Machaan) ( as per requirements of security agencies ) 31 CULTURE STAGE REQUIREMENTStage set up measuring 72ft x 52 ft. of at least three different levels ( 6ft,7ft &8ft) covered with grey carpet; Stairs: one stair complete on front side; and two stairs 6 feet wide on right & left side is required.Risers: approx. 8 ft. x 16 ft. with 1½ ft. height suitable for 8 to 10 artists to sit with dari/Kaleen covered with white cloth and Frontal steps all along the width.RedCarpet coveringthefrontofthe stage up to Sofa sets seating rows. 32 CULTURE AREA INCLUDING Well Ventilated Green rooms of size of 625 sq. ft. each separate for male and female interconnected with cultural stage. The green rooms to accommodate 150 artists in each at a time in vicinity of stage area, with wooden platformof 10cm with carpet, 20 banquets chairs with covers each, Garments hanger stand- 5 Nos each, 6 mirrors each, 2 shelves each. Green Rooms to be well lit with 6 nos. each light fitting of 40 watt each or compatible LED light fittings. 33 CULTURE AREA INCLUDING - Holding areas of 10 mtrs x 5mtrs each for cultural artists at an area in the vicinity of the cultural stage with wooden platform of 10 cm, carpet, Banquet chairswithcovers-20nos.eachandlightfittings of 40 watt- 4 nos. each or compatible LED light fittings. 34 Cultural Area: Air-conditioned portable Toilets in vicinity of main cultural stage with dedicated staff deployment with toiletries, amenities and adequate water supply at all time of event. 35 CULTURE AREA INCLUDING – VIP ExecutiveHigh Back Chair for Dais 36 CULTURE AREA INCLUDING – Centre Tablefor Dais 37 CULTURE AREA INCLUDING – Podium withPodium Boards 38 CULTURE AREA INCLUDING - Seating foraudience:- Sofa Double Seaters 39 CULTURE AREA INCLUDING - Seating foraudience:- Centre Tables( Coffee Table size) 40 CULTURE AREA INCLUDING - Seating foraudience:- Banquet chairs with chair covers and bands 41 CULTURE AREA INCLUDING - StageLighting:- Box Truss( 1000mm) 80 ft x 60 ft 42 CULTURE AREA INCLUDING - StageLighting:- Centre beam 70 ft 43 CULTURE AREA INCLUDING - StageLighting:- Side Cuts Section – 16 ft 44 CULTURE AREA INCLUDING - StageLighting:- LED PAR LIGHTS 54 x 3 Watt 45 CULTURE AREA INCLUDING - StageLighting:- Par 64 sealed beam 46 CULTURE AREA INCLUDING - StageLighting:- Laser light 47 CULTURE AREA INCLUDING - StageLighting:- Sharpy 48 CULTURE AREA INCLUDING - StageLighting:- Pointy 49 CULTURE AREA INCLUDING - StageLighting:- Aura 50 CULTURE AREA INCLUDING - StageLighting:- Profile 51 CULTURE AREA INCLUDING - StageLighting:- Follow Spot 52 CULTURE AREA INCLUDING - StageLighting:- Mole fays 53 CULTURE AREA INCLUDING - StageLighting:- Haze Machine 54 CULTURE AREA INCLUDING - Stage Lighting:- Grand MA Lighting CONTROL Panel with NPU. 55 PC LED Warm-400 watts 56 LED Fresnel warm 57 Dimmer Par 500 KW Electronic 58 Avolite Board 59 Cultural Area -Video - LED WALL - Centre 52ft x 16ft 60 Cultural Area - Video - Side Wings – LED Wall3.5 ft x16ft 61 Cultural Area - Video - Watch out Servers 62 Cultural Area - Video - Plasma TV 52 inch on stand for backstage 63 Cultural Area - Multi Camera HD Set up with 04 cameras with editing table, Jimmy Jip with crane and adequate manpower to operate 64 Cultural Area - Sound Requirements - line array D and B 65 Cultural Area - Sound Requirements - Base D and B 66 Cultural Area -Sound Requirements - Stage Monitor 67 Cultural Area - Sound Requirements - Side Fill Line array approx. 800 Watt each 68 Cultural Area - Sound Requirements- Corded Mikes 69 Cultural Area - Sound Requirements - Cordless Mikes 70 Cultural Area - Sound Requirements- Headset mike 71 Cultural Area - Sound Requirements - Foot Mike 72 Dynamic wired mikes of different sizes 73 Digital Console 96 Channels (sound engineers and adequate number of technicians to be available at all times during the event.) 74 Carpet on 26.01.2025 for Parade Gyanpath and outer area with Pasting. 75 Saw dust provision 76 Spinkler for water spray 77 Drummer Technical Rider1) Drum Kit: DW Performance or Yamaha Maple Custom (or similar).Completing: drums: bass drum 22’, tom 10’, tom 12’,floor tom16’;snare 14’,Cymbalspaistechokes; Hi Hat 14”, Ride 20”, Crash 16” and Splash 10” stands: one for hi-hat, one for snare drum, 4 (four)boom stands for cymbals besides hi-hat stand; Drum chair with adjustable height; all elements of drum kit should be located on a carpet or rubber covering (against sliding);Drum Riser is a mus + Monitors + in ear monitor-One shaker,2) in-ear Monitor3) Wedge Monitor One jackOne monitorOne keyboard stand One notation stand 78 Guitar tech rider:1. Guitar amp (Fender twin reverb/ Marshall JCM 900)2. Guitar stand3. 1 Amp(Fender Twin Reverb or JCM 900 or Marshal100HCFX Amp Head with 4 Speaker Marshal Cabinet )4. 1 Mic With Stand (Shure SM57)5. 2 DI Box6. 4 Guitar Aux7. 1 Guitar Stand8. In Ear monitor-1 no.9. Notation stand- -1 no. 79 Keyboard: (Keyboard TR) stereo wires 2DI Keyboard amp Keyboard stand 80 MAIN ARTISTSEENHIESER e845 only wireless MEDIUM BOOM STANDSMultifunction Power Extension Boards- 4 Nos 81 Harmonium1. SM58 One Laptop 82 Drums:Pearl session / Master / Pearl decade maple Or• Tama superstar Hyper drive/Tama Silver star/Star Classic• HI Hat 14 inch, Crash 18 inch, 16 inch Crash Ride 20 inch, China 16 inch, Splash 10 inch, with Stands and 1 extra Boom Stand(All from K Custom series of ZILDJIAN)Drum Mic Kit- Audix Mic Kit OR PGA and( Beta 52A For Kick separately) 83 OUTPUT PATCH 84 INPUT CHANNEL MONITOR 85 TaIkBactMac.ForCoordinationStageto Mixing Console with Monitor 86 Power source must be 280V, earthed aria connected ro a safety system thai breaks tke c rcu›r whenever Phase is connected to ground, 4 Power outlet Stripe are required for the musicians on Stage placed according to where the musicians at onstage. 87 Floor Monitor Monitors fPRx 8 S/SRX 8t5) 88 8 x: Floor Monitor S wzT1 carry their individual preferred mix for the musicians on stage side file 89 JBL SRX 725 WITH SRX 718-2 PAIR 90 Channel 22-23 Keyboard 2nos. DI BOX with PowerPoint Vocal mic. SM58 1no. With Tripod 8uom stand 91 MONITOR MIK.8 & 9 92 JBL Lirte Array w th sub Low 93 Two LED Plasma 60 inches with touch screen facility with dedicated 10 MBPS lease line for internet connectivity 94 Cultural Area Console : a dedicated 100 mpbs board band internet connectivity for live coverage & sharing on various SocialMedia Platforms 95 Reserved Lounge: To cater requirements for Dignitaries as per security agencies.- Construction of Space Frame Pillar less, Water Proof, Fire Retardant Aluminum hanger Structure 20m x 10m with fabric false ceiling with top and covered from all sides with wooden platform base of 10 cm with new carpet, Double Door Entrance and Exit, Well Lit befittingthe Ambiance as per our requirement- using fittings, cables etc of ISI standards, well ventilated, with colorful fabric and befitting interiors.10Nos. for entire Event Flower Bouquets and 8 Nos. for entire Event table top flower arrangements on daily basis. All material used should be in consonance to fire safety norms and adhere to fire safety standards. 96 Reserved Lounge: 10 nos. round table of 8 pax seating capacity each and 100 banquet chairs with covers. 97 Reserved Lounge: Sound system with adequate speakers, amplifier etc. with 8 number table mikes; 2 podium mikes and 4 number cordless mikes 98 Reserved Lounge: Sofa set ( Double Seaters) 99 Reserved Lounge: Centre Tables 100 Reserved Lounge: Side Tables 101 Reserved Lounge: Air Circulators 102 Reserved Lounge: Air-conditioned portable Toilets in vicinity of VIP Hanger with dedicated staff deployment with toiletries, amenities and adequate water supply at all time of event. 103 Reserved Lounge: Internet lease line 20 Mbps forcreating Wi-Fi zone with complete set up / infrastructure 104 Hangar for Ministry of Information & Broadcasting (I&B) Exhibition - Construction of 01 Nos. for entire Event of Space Framepillar less, Water Proof, Fire Retardant, Safe Aluminum Hanger Structure (10mx20m) with fabric false ceiling, 10cm wooden platform base with carpet and covered from three sides plus top and well lit. 20 number octonorm tables, 40 banquet chairs with cover. 05 Nos. air circulators and 10 Nos pedestal fans. The average electrical load should be 10KW including load required from 22nd January 2025fabrication of exhibition area. All materialused should be in consonance to fire safety norms and adhere to fire safety standards. 105 Hangar for Ministry of Tourism Experiential Zone - Construction of 01 Nos. for entire Event of Space Frame pillar less, Water Proof, Fire Retardant, Safe Aluminum Hanger Structure (10mx20m) with fabric false ceiling, 10cm wooden platform base with carpet and covered from three sides plus top and well lit. 20 number octonorm tables, 40 banquet chairs with cover. 05 Nos. air circulators and 10 Nos pedestal fans. The average electrical load should be 10KW including load required from 22nd January 2025 for fabrication of exhibition area. All material used should be in consonance to fire safety norms and adhere to fire safety standards. 106 Hangar for Ministry of AYUSH - Construction of 01 Nos. for entire Event of Space Frame pillar less, Water Proof, Fire Retardant, Safe Aluminum Hanger Structure (10 mtr. X 20 mtr.) with fabric false ceiling, 10cm wooden platform base withcarpet and covered from three sides plus top and well lit. 20 number octonorm tables, 40 banquet chairs with cover. 05 Nos. air circulators and 10 Nos pedestal fans. The average electrical load should be 10KW including load required from 22nd January 2025for fabrication of exhibition area. All materialused shouldbe in consonance to fire safety norms and adhere to fire safety standards 107 Hangar for Ministry of Railways - Construction of 01 Nos. for entireEvent of Space Frame pillar less, Water Proof, Fire Retardant, Safe Aluminum Hanger Structure (10 mtr. x 10 mtr.) with fabric false ceiling, 10cm wooden platform basewith carpet and covered from three sides plus top and well lit. 10 number octonorm tables, 20 banquet chairs with cover. 02 Nos. air circulators and 5 Nos pedestal fans. The average electrical load should be 10KW including load required from 22nd January 2025 for fabrication of exhibition area. All material used should be in consonance to fire safety norms and adhere to fire safety standards 108 Hangar for Ministry of Food Processing - Construction of 01 Nos. for entireEvent of Space Frame pillar less, Water Proof, Fire Retardant, Safe Aluminum Hanger Structure (10 mtr. x 10 mtr.) with fabric false ceiling, 10cm wooden platform basewith carpet and covered from three sides plus top and well lit. 10 number octonorm tables, 20 banquet chairs with cover. 02 Nos. air circulators and 5 Nos pedestal fans. The average electrical load should be 10KW including load required from 22nd January 2025 for fabrication of exhibition area. All material used should be in consonance to fire safety norms and adhere to fire safety standards 109 Hangar for Footwear Design & Development Institute - Construction of 01 Nos. for entire Event of Space Frame pillar less, Water Proof, Fire Retardant, Safe Aluminum Hanger Structure (10 mtr. x10 mtr.) with fabric false ceiling, 10cm wooden platform basewith carpet and covered from three sides plus top and well lit. 10 number octonorm tables, 20 banquet chairs with cover. 02 Nos. air circulators and 5 Nos pedestal fans. The average electrical load should be 10KW including load required from 22nd January 2025for fabrication of exhibition area. All material used should be in consonance to fire safety norms and adhere to fire safety standards 110 Food Court: Gazebo: Water proof, Specialized covered structure on truss for all over the venue at food court. Flat roof structure size10mx10m with 10cm wooden flooring with carpet and thematic colorful decoration to give a festive look. 111 Food Court - Water Proof Pagodas (5 mtr. x5 mtr.) with wooden platform base of 10 cm, carpet and each pagoda consisting of 3 light fittings of 40 watts each or compatible LED light fittings, Furniture- 4 Nos. working table of 6’ x 3’ with white disposable laminated sheets (to be changed regularly) 4 Nos. Plastic/ Banquet chairs, o1 No Pedestal fan, 5 Nos. power points, 1 nos. Dustbin, and 1 No. Fascia. The average Electricity load should be 5 KW in each pagoda. 112 Food Court – 5 Kitchen Areas of 250 SQM each tin Sheds and stone / brick surface with each kitchen areas consisting working tables of 6’ x 3’ (30 No’s in each kitchen area) with facility of water for cooking and dish washing. Kitchen area to be adjoining food court area. Allkitchen areas to have adequate fire safety measures like ABC fire extinguishers, sand bags, sand buckets, fire Marshalls etc., as per the fire safety guidelines 113 Food Court – Steel Dustbin with Garbage bags with clearance at regular interval and timely cleaning to maintain hygiene during the entire period of event. Theme of Swachh Bharat to be adhered. Large size with covers. 114 Food Court - Outdoor LED Wall 16ft x 8ft, with fabric Branding, Platform and sound system. 115 Food Court – Banquet (Plastic Tables) Tables Round with approx. 1.5 mtr. Dia (25 nos) with Umbrella and Rectangular/Square Dining Tables (25 Nos) with umbrella to accommodate 4/6 chairs each. Table covers for all tables. 116 Food Court – Banquet/ Plastic chairs with chair covers and bands/ Wooden chairs 117 Food Court - Bistro Tables with covers 118 Food Court - Stage for Performance of Nukkad nataks, size 50sq mtrs with 2 Ft height and steps on two side with sound system – 4 speakers, 10- standing mikes, 2 cordless mikes and 2 collar mikes. 119 Handicraft Area- Water Proof Pagodas (3 mtr. x 3 mtr.) Structure with wooden platform base of 10 cm, carpet and each pagoda to have 3 light fittings of 40 watts each or compatible LED light fittings, Spot Lights (9 nos), Furniture- 2 Nos. Octonorm Table 3’x 1.5’, Banquet/Plastic chairs with covers 2 nos., 3 Nos. Power Points, 1 No. Dustbin etc with Modular structure inside. Each Modular structure within each pagoda to have 9 shelves/slabs (3 on each wall) for display their products, Presentable Almirah (all equal size) withlockablefacilitytobeplacedineach handicraft and handloom pagoda and 1 No. fascia. 120 Handicraft Craft Area- Including: Dustbin with Garbage bags with clearance at regular interval and timely Cleaning to maintain hygiene during the entire period of event. Theme of Swachh Bharat to be adhered. 121 Handicraft Craft Area- Including: Outdoor LED Wall 16’x 8’ with fabric Branding with platform and sound system. 122 Handicraft Area: Internet lease line 20 Mbps for creating Wi-Fi zone with complete set up/ infrastructure 123 Handicraft Craft Area- Including State Theme Pavilions: Water Proof Pagodas (6 mtr x 6 mtr) Structure each with wooden platform base of10 cm, carpet with each to have 6 light fittingsof 40 watts each or compatible LED light fittings, Furniture- Octonorm Table 3’x 1.5’ - 04 Nos, Banquet chairs with chair covers 4 nos,Power Points 08 Nos, Spot lights -15 Nos, Dustbin -01 No, etc. with Modular structure inside.EachModularstructurewithineach theme Pavilion to have Presentable Almirah (all equal size) with lockable facility to be placed in each Theme Pavilion pagoda and 1 No. facia. Each theme Pavilion (6 mtr x 6 mtr) to have additional average Electricity load of 4 KW for each pavilionincluding Electric load required from 22nd January,2025 for fabrication of stalls) 124 HandicraftCraftArea-IncludingCentral Ministries/ Departments Pavilions: Water Proof Pagodas(5mtrx5mtr)Structureeachwith wooden platform base of 10 cm, carpet with each to have 6 light fittings of 40 watts each or compatibleLEDlightfittings,Furniture- OctonormTable3’x1.5’-04Nos,Banquet chairs with chair covers 4 nos, Power Points 08 Nos, Spot lights -15 Nos, Dustbin -01 No, etc. withModularstructureinside.EachModular structure within each theme Pavilion to have Presentable Almirah (all equal size) with lockable facility to be placed in each Central Ministry/ Department Pavilion pagoda and 1 No. fascia. Each Pavilion (5 mtr x 5 mtr ) to have additional average Electricity load of 4 KW for each pavilionincluding Electric load required from 22nd January,2025 for fabrication of stalls) 125 Neat Barricading and Fencing: Strong, proper, effective, presentable and complete barricading and fencing (using good material) of each tableau. (Total Tableaux expected to be 40) in parv area without disturbing the décor of the tableaux and inconvenience to the visitors 126 Military Band Stage - 4 sides open with for Military Bands of size 12m x 8.5m size with fabric branding on four sides with two side steps, carpet, with stage lighting (20 par /LED lights) from the front side of the stage 127 Military Band Stage -Sound system for Military Bands (48-piece band), 20 Micro phone, Cordless mikes -2nos and collar mikes- 2 nos, JacksandwiresforGuitar,keyboardand Octopad, Speakers -12 nos, Monitor speaker- 4 nos, Woofers and Tweeters, Mixer Channel, amplifier etc. 128 Military Band Stage - Banquet chairs with chair covers and bands with covers on band stages- 30 each stage 129 AYUSH Stage (Yoga Performance) 4 side open and covered on top with waterproof, stage for Yoga Performance of 12m x 8.5m size with 4ft. height with fabric branding on four sides with two side steps, carpet, with stage lighting (20 par/LED lights) from the front side of the stage. Sound System with Speakers, amplifiers,04 Cordless/Collar Mike & LED Wall 20’x10’ with platform. 130 Revolving / Rotating CCTV Cameras with wiring – (in entire event area including periphery, surrounding areas and parking),Installation and operation during entire event with Night vision capacity, monitoring andrecording and including deployment of technically trained manpower to monitor CCTV Operation. At the end of the event complete recording of all the days to be submitted in hard disk. 131 Fire Fighting - Provision (in entire event area including parking and surrounding areas) with firefighting equipment and manpower including Fire Tenders- 6, ABC Type fire extinguishers (10 Kg) – 300 Nos., Sand Buckets 300 andSand Bags – 750 Nos., Fire Marshalls– 40 Nos.and Fireman – 40 Nos. duly trained as perprevailing fire safety norms in uniform as per requirements of Authorities. 132 Conservancy and housekeeping - Provision of 250 Nos.cleaningStaffeach dayfor conservancyandmaintenanceoftheentire event areas including back areas, surrounding areasincludingsurroundingtoiletareasetc. Staff should be in proper uniform with cleaning equipment’s like vacuum cleaner, brooms, garbage bags etc. 133 Ceremonial Gas Filled balloons of Tri-colors and medium size- On the Inaugural Day only 134 Catering Arrangements at Reserved Lounge for 350 Pax (Each Day Menu to be changed on daily basis) Variety of Tea, coffee, cold beverages to be available on daily basis along with savory, sweet items like samosa, pakora, mini patties, dry Indian sweet, cookies and biscuits and 2 nos. water dispensing machines with 6 nos. drinking water jars of reputed brands approved by FSSAI with glass and disposable eco-friendly paper glasses. Well- groomed and uniformed staff to cater in Reserved Lounge. Menu to be change on daily basis 135 Office equipment’s: Computer with UPS 136 Office equipment’s : Printers along with paper for printing 137 Office equipment’s : Photocopier Machine with photocopier paper 138 Office equipment’s: Data cards for internet connectivity (4 GB) 139 Creative Branding in fabric: Creative and graphic designing of symbol of event with options, designing of view cutter, signage, backdrop, gates, 3D Cut out at various locations and direction indicator panels (as per input from principal organizer) in and aroundthe entire Parv Area and periphery. In addition, Interactive wall using good material- fabric, wood crafted jaalis, fabric prints using 3-D effects, selfie points; Graffiti walls, masks; Dance Postures with Special Emphasis on concepts like “Viksit Bharat @ 2047” “Vikas bhi Virasat bi” “One District One product”, “Nari Shakti, Millets, Life Millets, Travel for Life”,”Ek Bharat Shrestha Bharat” etc. to create and enhance the ambiance to give patriotic, festive and colorful look as well as for more public participation. The entire creatives for branding will be as perthe approval of Ministry of Tourism. 140 Cloth masking on frame of entire Boundary wall with 09 Feet height as per site requirement. 141 Creative Zone: for activities like short quiz competition, face painting/ tattoos, Karaoke activities with sound systems for public participation with activity co-coordinators and any other participative concepts with adequate coordinators etc. 142 30 Nos. of Drinking water dispensers equipped with 20 Ltr. Packaged Drinking water jar of reputed brand, replenish able CAN/JAR with sufficient disposable eco-friendlycups (CAN/JAR to be replaced at regular interval for un-interrupted supply) on daily basis for entire event. 1000 jars of 20 ltr per day 143 Still and Video Photography of entire Event – comprising of two single Camera Setup withlive projection in Food Court and Handicraftarea and at least 4 still photographers. Softcopy of photo shoot and video recording to be handed over on daily basis/as and whenrequired basis to ITDC for entire event including photo Album/s, DVD’s and teasers(short clippings of 3 to 5 minutes’ duration for the event as per the requirements of Ministry). 500 nos. of photos (5”x7”) with presentable album. All data pertaining to Bharat Parv to be delivered in a separate hard disk. 144 Toilets for General Public (Male and Females) with hand washers with liquid soap, proper water facility and their cleanliness at regular intervals and to maintain proper hygiene. All the toilets in the parv area to have provision of light inside. 145 Drinking water Tanker - 5000 Ltr. in Food Court area for kitchen purpose - on Daily basis. 10 Water tankers of 5000 liter each per day 146 Central PA System for entire venue (Help desk and control rooms ) 147 Battery Operated Golf Cart with driver for VIPs ( 5 +1) seating capacity each 148 Wheel Chairs for Differently abled persons 149 Walkie-TalkiesCommunicationDeviceswith System 150 Kitchen Apron of size 42”x24” with strap andgood quality fabricwith Incredible India branding 151 Umbrella large size with Branding 152 Media Hanger structure in Food Court Area: To cater requirementsfor Media Personnel: Construction of Space Frame Pillar less, Water Proof, Fire Retardant Aluminum hanger Structure with fabric false ceiling of size 15m x 10m with top and covered from all sides with wooden platform base of 10 cm with new carpet, Double Door Entrance and Exit, Well Lit befitting the Ambience as per our requirement- using fittings, cables etc of ISI standards, well ventilated, with colorful fabric and befitting interiors, 8 nos. table top flower arrangements on daily basis. All material used should be in consonance to fire safety norms & adhere to fire safety standards. 153 Media Lounge: Sofa set ( Double Seaters) 154 Media Lounge: Centre Tables 155 Media Lounge: Side Tables 156 Media Lounge: Office set –up: Computers with UPS 157 Media Lounge: Office set –up Black and White Printers with printing paper 158 Media Lounge: Office set –up Colour Printers with printing paper 159 Media Lounge: Internet lease line 20 Mbps for creating Wi-Fi zone with complete set up/infrastructure 160 Media Lounge: Output Box with 20 Points for Media 161 Media Lounge: Office set –up Photocopy Machine with adequate photocopy paper and stationery. 162 Media Lounge: Office setup - Octonorm Tables 3ft x 1.5ft 163 Media Lounge: Office setup - Banquet chairs with chair covers 164 Media Lounge: Office setup - Power points 165 Media Lounge: Office setup – s t e e lDust bin 166 Media Lounge: Arrangements for press briefing for 75-100 pax with banquet chairs and head table for 5 pax. Audio Visual arrangements with 5 mikes for head table and 4 cordless mikes for Q and A. Podium with Podium Board and 2 mikes. Flower arrangements for head table. 167 Catering Arrangements for 300 Pax per day at Media Lounge – (Each Day; Menu to be changed on daily basis). Variety of Tea, coffee, cold beverages to be available on daily basis along with savory, sweet items like samosa, pakora, mini patties, French fries, Dry Indian sweet, cookies and biscuits and 2 nos. water dispensing machines with 4 nos. drinking water jars of reputed brands approved by FSSAI with glasses and disposable eco-friendly paper glasses. Well-groomed and uniformed staff to cater in Media Lounge. 168 Media Lounge: Enclosure with 4 tables and chairs for dedicated catering 169 Air-conditioned portable toilets in vicinity of Media Lounge with dedicated staff deployment with toiletries, amenities and adequate power supply, water supply at all time of event. 170 Air Circulators for Media Hangar 171 Studio Kitchen Stage built on 18” inches raised wooden platform with 240 degree open,one entry and exit, size 12 x 8 with running water , attached mise en place area size 6 x 12 with running water facility and wash up area size 6x12 with sink and running water facility for Washing utensils, Size of Studio kitchen tent should be 20 x 40 with waterproof roof and barricading of 3 feet height with one entry and exit 172 Studio Kitchen: Theatre seating with 50 banquet chairs with covers in front of the studio kitchen. 173 Studio Kitchen Sofa set for VIP (Single Seater) 174 Studio Kitchen Power Point 15Amp 175 Studio Kitchen Electrical Load 176 Studio Kitchen: Video Camera placed on the working area and both sides with complete recording of entire event 177 Studio Kitchen LED Screen size 12x8 178 Studio Kitchen Collar Mike 179 Studio Kitchen Sound System with four Speaker 180 Studio Kitchen Fire Extinguishers –ABC Type 10 Kg, Sand Buckets and Sand Bags 181 Studio Kitchen Chef Caps with Incredible India Print 182 Studio Kitchen: 04 Utility workers for the studio kitchen per day 183 Pathway: Wooden platform of 10cm with grey carpet properly fixed throughout the Parv area to access the food court stalls, stage, Handicrafts and Handlooms stalls, State Theme Pavilion, VIP Lounge, Media Lounge, I&B Hangar, Hangars, offices of ministries, ITDC and Public Conveniences etc. The entire pathway to be with grey carpet (properly fixed) and approx. of size 8 ft. in front and 4 ft. in back of all the areas for smooth movement of public at large. The pathway to also be disabled friendly with interconnected pathway facility with platforms at various places includingconnectivity from Gyanpath to both the lawns. The pathways to be made with clear cut space for movement of differently abled persons’ in wheelchair. 184 Green net spread all across the parv area except the wooden platform ,Pathway to control Dust 185 Arrangement of sprinkling of water on daily basis to settle dust in the Parv area 186 Office Equipment: Comprising of: Computers with UPS and skilled manpower for Registration (preparation of badges etc.) with printers for colored and black and white printing along with stationery and paper. 187 Office Equipment: Heavy Duty Photocopier machine along with stationery and photocopy paper 188 Manpower: Ushering Staff per day (Female).12Hrs Shift Presentable, soft – spoken duly uniformed as per our requirement. Uniform to be provided by the bidder. 189 Manpower: Assistants (Male) per day 12 Hrs. shift. Presentable, soft – spoken duly uniformed as per our requirement. Uniform to be provided by the bidder. 190 Augmentation of lights over and above normal lighting for a well-lit Parv Area and surrounding area with 300 nos. LED metal lights. 191 Divider Railing: To regulate smooth entry and exit of visitors to the food court area and the tableaux/ handicraft area. As per our requirement. 192 Security Items or Services: Tensil Canopies of water proof stretchable fabric with MS Frame to cover 40ftx13 ft to cover 10 No’s DFMD at entry points 193 Tableaux Lighting: LED Parcan up lighters for Tableaux area 194 Water for cultural Artists: 4 nos. water dispensing machines with 50 nos of 20 litre each drinking water jars of reputed brands approved by FSSAI for the cultural artists eachday with ecofriendly disposable paper glasses 195 Promotional Tee Shirts with assorted sizes having Incredible India & Travel for LiFE Logo (as per size requirements) 196 Lamp Lighting With accessories viz oil, wicks, candle, floral decoration etc 197 ProvisionofcoveredkioskswithiPadsor equivalentsoftwarewithgadgetsatvarious places in the parv area to provide pre - ordering of food to avoid crowd at the counters in the food court. 198 Dedicated Social Media team to promote & publish the event on various social media platforms and under overall supervision/ Guidance / requirement of Ministry of Tourism. 199 A special stage of size 24ft x 12 ft with carpet and with all necessary audio visual systems at the venue for on – the – spot performance by kids up to 14 years old.
Contract Date : 26 Jan, 2025   |   Contract Value : 5.50 Crore
BRR : 7607287 Tender For Konch Nagar Palika Parishad water Supply scheme Under Amrut 2.0 Distt. Jalaun - Construction of R.C.C Over Head Tank (OHT)Supply of all the materials, labour T&P and construction of a R.C.C. Over head tank above ground level with main components, based on IS-3370 or liquid storage concrete in over head tank and foundation concrete as per specification in I.S. 2911.Following capacity/StagingAll Components of OHT will be casted in M-30 concrete with cement, coarse sand and approved stone grit as per I.S. 11682 and I.S. 456.Minimum depth of foundatation below original ground level will be 2.50 M.Seismic effects and wind load should be taken into consideration as I.S. 1893for earthquake resistance and I.S. 875 part-III for wind load on structure. The asumed bearing capacity of soil has been taken as 8 M.T. sqm.1m wide RCC dog legged stair case from ground lavel to balcony.M.S. ladder made of 50 X 50 X 6 mm angle section and 20 mm plain M.S. bars (specification of M.S. should be as per IS 800-2007) with hand rails of 20 mm medium class G.I. pipes on both sides in three rows from balcony to top dome resting on an RCC plateform (75 X 75 cm and 10 cm thick) projecting from top ring beam and one alluminium ladder inside the tank body (from manhole to tope dometo bootom dome).1 m wide R.C.C. balcony around the tank at the junction point of vertical wall and conical wall.Proper R.C.C. railing and 20 mm dia medium class G.I. pipe (in 3 rows) on both sides of stair case, arround the balcony at each landing from landing with top ring beam upto manhole on the top dome and at the periphery. The G.I. pipes will be supported on R.C.C. postsof 100 mm dia or on the posts made of 50 X 50 X 6 mm M.S. angle section, spaced at intervals not more than 1.5 m.Proper ventilator at top dome in circular shape of 1.2 m dia along with an R.C.C. cover of minimum 1.50 m dia and 7.5 cm thicknes.The space between top dome and R.C.C. cover should be covered with mosquito net of standered qualitity along with expended mentaled jail.Electro Megnatic Flow Meter.Lightening conductor as per I.S.S. 2309 of its latest amendments of latest electricity rules. It should consistproper elevation rod with 5 or more fork points proper down conductors of prescribed mental of proper size prescribed by ISS 2309-1969 and ISS 3013-1966.D.I. manhole of min 60 X 60 cm size made of M.S. channel section with adequate cover made of M.S. sheet of minimum 3mm thickness hinged with manhole with locking arrangment. This manhole should be fixe at top dome at proper place.suppply od fixing of all down pipes and valves as per Tender document . includingsoil testing (detail specification as per tender document) 2 Zone -2 1600KL/18M 3 Zone -3 1700KL/18M 4 Renovation of R.C.C Over Head Tank (OHT) 5 Dismantiling of OHT DemagedFlooring Scrappingofold Surface OHT leakage RepairingPressure GroutingCement and water Proofing Coumpond Chemicalinternal wall and bottom dome to making of water tightness oftank body Repairing of Railing of Stair and Balcony with 20mm GI Pipe including changing of old pipe and refixing new pipe with angle ironpost Supply and Fixing of MS Stair Gate with box in 1/2 flight primar and painting complete cover and steel mosqueteo mesh in ventilatorlightening conductor making proper earthing Supply and Fixing ofDigital Water Level Indicator .Painting of OHT Shuttering centringflooring Painting two coats of approved paint Apex Ultima ofOHT including supply of all materials, labour and T&P etc required for Proper completion of the work in External of whole OHT with writing Of Scheme Details in tank Body .Ladder inside and outerside of tank bodyWith railing. Repairing & Paintingof inlet, outlet, overflow and washoutpipe with black japan paint and flow mark with white paint.Replacement / repairing sluice valve and chamberwith all material etc complete.,all work instructed by engineer in charge 6 Zone -1 7 Existing Tank 8 Construction of R.C.C clear water reserviour (C.W.R) cum pump house of various at different site 9 Design & supply of allmaterial T&P etc and constructRCC CWR cum pump house offollowing capacity with GI pipes railling consisting of 3 rows of 20 mm dia G.I pipe and angle iron posts of the dome periphery, S.S ladder from ground level to top of tank andaluminium ledder inside the tank, locking device, ventilator, supply and fixing digitalwater level indicator, 25mm PCC 1:2:4 over 80mm PCC 1:4:8 in apron, 150 mm semicircular drain around the tank, two coats of apex paint and testing of tank for water tightness etc. and also including the cost of supply and fixing of all necessary pipes and valves etc all complete as per approved design and drawing.(Detail specification as per tender document) 10 575 KL in Zone 2 11 625KL in Zone 3 12 Rising Main 13 Supply ofDI K-7/K-9 Pipes of follwing sizes (Dia in mm) / Thickness as IS 8329/2000 or its latest amendment with jointing materials, specials of sizes required during construction included jointing material upto site of work included loading unloading cartage insurance, etc all completed but exclusive of GST in various zone as per the drawing and approval to Engineer. 14 DI K-7 200mm Dia 15 DI K-7 250mm Dia 16 DI K-7 300mm Dia 17 DI K-7 400mm Dia 18 Supply of following size ofSluice Valves/ Scour Valves,capable for working pressure of 10 kg/cm2 Fire hydrants & Air Valves as per relevent I.S. Codeor its latest amandement. Up tosite store Including loading, unloading & cartage, taxes duties insurance , exclusive GST etc all complete. As per IS: 2906-1969. 19 Air Valve as per as I.S : 14845 20 20 mm dia 21 D.I. D/F Sluice valve/ Scour valve 200mm Dia 22 Cartage of following size (dia in mm.) of DI K-7/K-9 pipesand specials includingjointingmaterials from store to site of worklowering the same into excavated pipe line trenches true toalignment and gradiant and jointing the same including testing of pipe line aincluding supply of all materials labaour T&P etc complete also and as per direction of engineer incharge 23 DI K-7 200mm Dia 24 DI K-7 250mm Dia 25 DI K-7 300mm Dia 26 DI K-7 400mm Dia 27 Carting of following size of Sluice Valves/ Scour Valves,from store to site of work and lowering them into the trenches, fixing in position and jointing them with Pipe line and testing etc including supply of jointing materialand also including supply of all material and construction of suitable P.C.C Support below fittings etc. complete. 28 Air Valve as per as I.S : 14845 29 20 mm dia Dia 30 D.I. D/F Sluice valve/ Scour valve 200mm Dia 31 Dismantling of following types of roads including sorting out of servicable matarials stacking and disposal of unservicable materials with in a distance of 50 m. including supply of labour specials T&P etc. required for proper completion of work and road should be mortarable within 7 days after laying of pipe line. 32 Interlocking tile 33 C C Road 34 Bitumenous Road 35 B.O.E Road 36 Reinstatement of following types of roadsincluding supply of required new matarials & reinstatement the same includng supply of required for proper completion of work.supply of all materials labour T&P etc complete and as per direction of engineer incharge and specificationand conditions in tender dpcument 37 Interlocking tile 38 C C Road 39 Bitumenous Road 40 B.O.E Road 41 Excavation for pipe line trenches in ordinary soil use ofspecialT&P etc. with lift upto 1.5 m lead upto 50 mincluding filling back of excavated earth into trenches and watering ranmming dressing and removal of surpluas earthas direcetedincluding supply of all materials labour T&P etc complete and as per direction of engineer incharge. also includes barricading and dewatering (if required ) oftrench. 42 R.C.C. Thrust block with cement, core sand, and 20mm gauges stone ballast in propotion of 1: 1.5:3 in thrust block of pipe line including reinforcementand its bending the same with 0.08 mm thick binding wire in position and necessary shuttering including proper curing and supply of all materials, labour and T&P etc required for proper completion of work. 43 Thrust Block 44 Provision for Road crossing including all materials, labour and T&P etc. complete. It includes supply of D.I. pipe of necessary size for encasing, cement concrete and Brickwork for pillars and any other job for proper completion of work. 45 For crossing of road up to 3.5 m wide 46 For crossing of road up to 7.0 m wide 47 Provision for Road crossing including all materials, labour and T&P etc. complete. It includes supply of D.I. pipe of necessary size for encasing, cement concrete and Brickwork for pillars and any other job for proper completion of work. 48 For crossing of nalla upto 3.5 m wide 49 For crossing of nalla upto 20 m wide 50 Constuction of following type of chamber as per type design & drawing & as per diretion of engineer incharge including all supply of materials etc. 51 Sluice valve/Scour Valve chamber (Masonary type ) 52 Air Valve chamber 53 DISTRIBUTION NETWORK 54 Supply ofHDPE Pipes grade PE 100/ PN 6 of follwing sizes (Dia in mm) / Thickness as IS 4984/2016 or its latest amendment with electrofusion jointing materials, specials and fittings of sizes required during construction included jointing material upto site of work included loading unloading cartage insurance, etc all completed but exclusive of GST in various zone as per the drawing and approval to Engineer. 55 HDPE PIPE GRADE PE 100/ PN 6- 90 mm 56 HDPE PIPE GRADE PE 100/ PN 6- 110 mm 57 HDPE PIPE GRADE PE 100/ PN 6- 125 mm 58 HDPE PIPE GRADE PE 100/ PN 6- 140 mm 59 HDPE PIPE GRADE PE 100/ PN 6- 160 mm 60 Supply of ISI Marked or its relevant code DI K-7 Pipes of follwing sizes (Dia in mm) with jointing materials and specials, during construction as per latest I.S amendement upto site of work included loading, unloading, cartage insurance, etc all completed but exclusive of GST in various zone as per the drawing and approval to Engineer 61 D.I. K-7/ 150 mm 62 D.I. K-7/ 200 mm 63 D.I. K-7/ 250 mm 64 D.I. K-7/ 300 mm 65 Supply of following size ofSluice Valves/ Scour Valves,capable for working pressure of 10 kg/cm2 Fire hydrants & Air Valves as per relerelavent I.S.I or its latest amandement. Up to store Including loading, unloading & cartage, taxes duties insurance etc all complete. As per IS: 2906-1969. 66 Air Valve as per as I.S : 14845 67 20 mm. dia Air Valve 68 D.I. D/F Sluice valve/ Scour valve 69 80 mm dia. 70 100 mm dia. 71 125 mm dia. 72 150 mm dia. 73 200 mm dia. 74 250 mm dia. 75 300 mm dia. 76 Fire hydrant (80 mm dia.) 77 Dismantling of following types of roads including sorting out of servicable matarials stacking and disposal of unservicable matarials with in a distance of 50 m. including supply of labour specials T&P etc. required for proper completion of work 78 Interlocking tile 79 C.C Road 80 Bituminous Road 81 B.O.E Road 82 Excavation for pipe line trenches in ordinary soil use ofspecialT&P etc. with lift upto 1.5 m lead upto 50 mincluding filling back of excavated earth into trenches and watering ranmming dressing and removal of surpluas earth as direcetedincluding supply of all materials labour T&P etc complete and as per direction of engineer incharge. also includes barricading and dewatering (if required ) oftrench. 83 Cartage fromstore to site of work for following size (dia in mm)HDPE pipes and Specials coupling, fittings, and lowering the same into trenches and laying true to alignment and gradiant including testing of pipe lines cuttings of pipes for making up the length and making joints with electrofusion couplers, bands, tees, endcap etc. with electrofusion machinery including all jointing materials, labour, T&P etc required for proper completion of work. (excluding cost of trenching) 84 HDPE PIPE GRADE PE 100/ PN 6- 90 mm 85 HDPE PIPE GRADE PE 100/ PN 6- 110 mm 86 HDPE PIPE GRADE PE 100/ PN 6- 125 mm 87 HDPE PIPE GRADE PE 100/ PN 6- 140 mm 88 HDPE PIPE GRADE PE 100/ PN 6- 160 mm 89 Cartage of DI K-7 pipes and specials of following size (dia in mm)from store to site of work, lowering them into trenches and laying true to alignment and gradiant including testing of pipe line but excluding cost of trenching including all supply of Labour T&P etc complete required for proper completion of work. 90 D.I. K-7/ 150 mm 91 D.I. K-7/ 200 mm 92 D.I. K-7/ 250 mm 93 D.I. K-7/ 300 mm 94 Carting of following size of Sluice Valves/ Scour Valves, Fire hydrants & Air Valves from store to site of work and lowering them into the trenches, fixing in position and jointing them with Pipe line and testing etc including supply of jointing materialand also including supply of all material and construction of suitable P.C.C Support below fittings etc. complete. 95 20 mm. dia Air Valve 96 D.I. D/F Sluice valve/ Scour valve 97 80 mm dia. 98 100 mm dia. 99 125 mm dia. 100 150 mm dia. 101 200 mm dia. 102 250 mm dia. 103 300 mm dia. 104 Fire hydrant (80 mm dia.) 105 R.C.C. Thrust block with cement, core sand, and 20mm gauges stone ballast in propotion of 1: 1.5:3 in thrust block of pipe line including reinforcementand its bending the same with 0.08 mm thick binding wire in position and necessary shuttring including proper curing and supply of all materials, labour and T&P etc required for proper completion of work. 106 Thrust Block 107 Reinstatement of following types of roadsincluding supply of required new matarials & reinstatement the same includng supply of required for proper completion of work.supply of all materials labour T&P etc complete and as per direction of engineer incharge specificationand conditions in tender dpcument 108 Interlocking tile 109 C.C Road 110 Bitumenous Road 111 B.O.E Road 112 Supply of all matarial labour T&P etc and constuction of following type of chamber as per type design & drawing & as per diretion of engineer incharge . 113 Sluice valve chamber 114 Scour Valve Chamber 115 Air Valve chamber 116 fire hydrant chamber 117 Provision for Road crossing including all materials, labour and T&P etc. complete. It includes supply of D.I. pipe of necessary size for encasing, cement concrete and Brickwork for pillars and any other job for proper completion of work. 118 For crossing of road up to 3.5 m wide 119 For crossing of road up to 7.0 m wide 120 Provision for Road crossing including all materials, labour and T&P etc. complete. It includes supply of D.I. pipe of necessary size for encasing, cement concrete and Brickwork for pillars and any other job for proper completion of work. 121 For crossing of nalla upto 3.5 m wide 122 For crossing of nalla upto 20 m wide 123 Building works 124 Construction of Pump House Cum Chloronome (3.0 M X 2.5 M X 3.0 M , 1.8M X 1.2 M X 3.0 M, 1.5 WIDE VARANDAH)as per approved drawing and design based on RCCsingle reamed pile foundation , foundation beam, D.P.C. ,Ist class brick work ,M.S. Angle iron chaukhat of 50mm x 50mm x 6mm size for doors and windows, lintels, sun, shades slab etc,t concrete floor andapron on all sides ,by pass chamber ,Painting and varnishing of new iron work with one coat priming and two coat of approved apex paint and varnish ,Finishing walls with waterproof cement paint of approved make and quality yover one priming coat on new work with two coats to give an even shade, Supply of all material labour T&p complete as per instruction of engineer in charge. 125 Zone -1,2.3 126 Repairing of Pump HouseAs required including Ist class brick work ,M.S. Angle iron chaukhat of 50mm x 50mm x 6mm size for doors and windows, lintels, sun, shades slab etc,t concrete floor andapron on all sides ,bypasschamber,Painting and varnishing of new iron work with one coat priming and two coat of approved apex paint and varnish,Finishing walls with waterproof cement paint of approved make and qualityover o ne priming coat on old work with two coats to give an even shade,Supply of all material labour T&p complete as per instruction of engineer in charge. 127 Construnction of a half set of (area 45 sqm) one no. single Room staff quarters for Operator staff, pump operator , chaukidaar, pump attendent and other as per approved drawing and design based on RCCsingle reamed pile foundation , foundation beam, D.P.C. ,Ist class brick work ,M.S. Angle iron chaukhat of 50mm x 50mm x 6mm size for doors and windows, lintels, sun, shades slab etc,concrete floor andapron on all sides ,by pass chamber ,Painting and varnishing of new iron work with one coat priming and two coat of approved apex paint and varnish ,Finishing walls with waterproof cement paint of approved make and quality yover one priming coat on new work with two coats to give an even shade, Supply of all material labour T&p complete as per instruction of engineer in charge 128 Zone-1 ,2, 3 129 Construction of office building /admin Block(15X10X3.60) as per approved drawing and design based on RCCfram structure with cpwd / PWD norms and specification for OFFICE BUILDINGS including Supply of all material labour T&p complete as per instruction of engineer in charge 130 Sub station building consisting HT pannel room (5*4.5*3.6),MCS room(5*4.5*3.6) and meter room (4*3m*3.6)at praposed CWR site of zone 2 and 3 131 HT pannal room as per approved drawing and design based on RCCsingle reamed pile foundation , foundation beam, D.P.C. ,Ist class brick work ,M.S. Angle iron chaukhat of 50mm x 50mm x 6mm size for doors and windows, lintels, sun, shades slab etc,t concrete floor andapron on all sides ,by pass chamber ,Painting and varnishing of new iron work with one coat priming and two coat of approved apex paint and varnish ,Finishing walls with waterproof cement paint of approved make and quality yover one priming coat on new work with two coats to give an even shade, Supply of all material labour T&p complete as per instruction of engineer in charge 132 Master control scada room(5.0x4.5x4.0m) as per approved drawing and design based on RCCsingle reamed pile foundation , foundation beam, D.P.C. ,Ist class brick work ,M.S. Angle iron chaukhat of 50mm x 50mm x 6mm size for doors and windows, lintels, sun, shades slab etc, concrete floor andapron on all sides , cable duct and other ,Painting and varnishing of new iron work with one coat priming and two coat of approved apex paint and varnish ,Finishing walls with waterproof cement paint of approved make and quality yover one priming coat on new work with two coats to give an even shade, Supply of all material labour T&p complete as per instruction of engineer in charge 133 Meter room as per approved drawing and design based on RCCsingle reamed pile foundation , foundation beam, D.P.C. ,Ist class brick work ,M.S. Angle iron chaukhat of 50mm x 50mm x 6mm size for doors and windows, lintels, sun, shades slab etc, concrete floor andapron on all sides,Painting and varnishing of new iron work with one coat priming and two coat of approved apex paint and varnish ,Finishing walls with waterproof cement paint of approved make and quality yover one priming coat on new work with two coats to give an even shade, Supply of all material labour T&p complete as per instruction of engineer in charge 134 Construction of 1.8m high boundary wall on pile foundation as per approved design and drawingand as per specification given in bid document inluding painting with 2 coats of all waether apex paint over one coat primer painting primer coat including supply of all material labour T&P etc for propercompletion of works as per instruction of engineer in charge. 135 Water Campus Zone 1,2,3 136 Filling of earth of lower portion including carting of earth upto 10 km including ramming , levelling and dressing at water works campus. 137 Provide all materials, labour, T&P etc Required for proper completion of work and construct Interlocking Tiles approach road, laid dry and joints intact with coarse sand mortar including preparation of base as per specifications and instructions of engineer incharge. 138 Water Campus Zone 1,2,3 139 Construnction of Drain in Water works Campus30 x 30 cm including labour material and t&p all complete as per specifications and instructions of engineer incharge. 140 Zone-1 ,2,3 141 Dismental of Old OHT in zone 2 400 KL/10 M satgingin fornt of fire station konch including labour material, scaffoldingand t&p all complete as per specifications and instructions of engineer incharge. 142 NEW HOUSE CONNECTION 143 Making new House Connectionwith Distribution main of following dia and type of road including Dismantling and Reinstatement of road . Supply, cartingof elecrofusion specials as Saddel ,Tee ,Bend,brass ferrule, Union,H.D.P.E. pipe , HDPE adeptor ,GI pipe for drain crossing and avobe GL,loweringtheminto trenches , fixing them with CC block and clampincluding bailing out of water necessary excavation for connection with brass Tap including all labour , T&P etc. required for proper completion of the work. 144 In C.C. Roads 145 For 90 mm to 110mm dia 146 For 125 mm to 160 mm dia 147 For 180 mm to 250 mm dia 148 For 250 mm to 300mm dia 149 In Bitumenous Roads 150 For 90 mm to 110mm dia 151 For 125 mm to 160 mm dia 152 For 180 mm to 250 mm dia 153 For 250 mm to 300mm dia 154 In B.O.E. Roads 155 For 90 mm to 110mm dia 156 For 125 mm to 160 mm dia 157 For 180 mm to 250 mm dia 158 For 250 mm to 300mm dia 159 In C.C. Interlocking Tiles Roads 160 For 90 mm to 110mm dia 161 For 125 mm to 160 mm dia 162 For 180 mm to 250 mm dia 163 For 250 mm to 300mm dia 164 SHIFTING HOUSE CONNECTION 165 Shifting of house connection from extsting distribution line to new pipe line in followingdia,withsupply of H.D.P.E. Average 6.00 mtr includingelectrofusion specials, Brass ferrule, Electrofusion Saddle clamp,tee bend ,union ,brass tap etc. of suitable size, resting on cc platform below ground level T&P etc. including excavation, laying and jointing for proper completion of work as per instructions of Engineer-in-charge includingthe cost of baling out and subsequent backfilland repair of subsequent leakages of joints, fittings and specials during work. 166 In C.C. Roads 167 For 90 mm to 110mm dia 168 For 125 mm to 160 mm dia 169 For 200 mm to 250 mm dia 170 In Bitumenous Roads 171 For 90 mm to 110mm dia 172 For 125 mm to 160 mm dia 173 For 200 mm to 250 mm dia 174 For 250 mm to 300mm dia 175 In B.O.E. Roads 176 For 90 mm to 110mm dia 177 For 125 mm to 160 mm dia 178 For 200 mm to 250 mm dia 179 In C.C. Interlocking Tiles Roads 180 For 90 mm to 110mm dia 181 For 125 mm to 160 mm dia 182 For 200 mm to 250 mm dia 183 For 250 mm to 300mm dia 184 E&M WORKS 185 TUBEWELLCONSTRUTION(SIZE300MMX200MM) 186 Resistivity Survey of Tubewell Site 187 Transportation of rig machine erection, dismantling and associated T&P Complete in all respect including required all material , labour etc. 188 DRILLINGOFTUBEWELLBORE 189 Drilling of 625 mm. dia bore from G.Į. to 70 M. BGĮ (12x 70 mtr) 190 Drilling of 500 mm. dia bore from 70 BGĮ to 100 M. BGĮ (12x30mtr) 191 Drilling of 500 mm. dia bore from 100 BGĮ to 125 M. BGĮ (12x25mtr) 192 Įogging of bore hole by electirc logger 193 TUBEWELLASSEMBLY-MSERWTubewellassemblywithall required parts like plain pipe, slotted pipe, MS rings, well cap, bail plugclamp,reducer,centralguide,supportstructureetc.as required and as per typed design complete in all respect. 194 300 mm. dia 7.1 mm thick MSERW Plain Pipe with MS ring & reducer 195 200 mm.dia 7.1 mm thick M.S. Plain pipe & Slotted pipe with MS ring 196 LoweringofTubewellassemblydulyweldedincludingwelding electrode 197 300 mm. dia 7.1mm thick MSERW Plain / Slotted Pipe (12x62mtr) 198 200 mm. dia Plain/Slotted Pipe 63 M. BGĮto 100 M. BGĮ(12x38mtr) 199 200 mm. dia Plain/Slotted Pipe 101 M. BGĮto 112 M. BGĮ (12x12mtr) 200 Supply & Shruoding of Įal Kuan Pea Gravel 1.6 to 4.8 mm. size for Tubewell (12x36cum) 201 DEVELOPMENTOFTUBEWELL 202 Transportation, Erection, Dismantling of 250 P.S.I. Compressor. 203 Charges for Development by 250 P.S.I. Compressor per hour.(12x55 hrs) 204 Transportation, Erection, Dismantling of 2 Cusec O.P. Unit and yeild Test. 205 Charges for Development by 2 Cusec O.P. Unitper hour.(12x75hrs) 206 ChemicalandBacteriological testofwatersampleform departmentel / NABĮ approved lab. 207 CLEARWATERSUBMERSIBLEPUMPINGPLANTFORTUBEWELLSTOOHTZONE-1 208 Supply,installation,testingandcommissioningofClearwater submersiblepump(IS9236)completewithelectricmotor(IS8034) capable to operate on 380/420 volts 3 phase 50 c/s A.C. Capable for giving 900LPM,62MtrHead,25HPforNew Tubewell. 209 Supply,installation,testing andcommissioningof Main Piping & Valves with24Mtr.Columnpipe,bend,Tee,powerwiring,earthing,painting, wiring of pump house (Internal & External)complete in all respect with all required material, T&P labour 100mmDia.size. 210 Supply of 3 Mtr Įong Heavy duty exta Coloum pipe 100 mm Dia. Size (8 No for each TW ) 211 Supply of Motor operated actuators forsluice valve suitable for SCADA operationwithlimitswitches,autodeclutchformanualoperationin emergencyetcasperrelevantISsuitablefor100 mm dia size sluicevalve 212 Supply of D.I./ D.F. Dismantling Joints is a variable length Double Flanged ShortPiececonstitutedbya flange/ SpigotTailpieceinsertedintothe other Tailpiece which allows the distance between the two flanges to be variedwithincertainlimitsthusprovidingavariabledistancepiece betweentwofixedflangeenddeviceslikePumpsandValves.The Dismantling Joint to be supplied complete with Sealing Rubber Gaskets of EPDM quality (IS:5382/1985 Type-4), Cast Iron Follower Glands and Mild Steel (Zinc Coated) Nut Bolts of 100mm diasize 213 ExtraSubmersibleflatcoppercondutorcable3Cx6sq.mmPVC Sheathed double run (2Rx30m = 60 mtr for each TW) 214 Supply& laying of Į.T. XĮPE insulatedarmouredaluminiumconductor cable of 1.1 KV grade Material :- H4- Grade aluminium conductor of purity>99.6%&asperIS:1554P-I/IS:7098P-(I),conductorshallhave electrolytic aluminium confirming to IS 8130, IS 3975-1999.From transformer to Main ĮT panel of 3.5Cx 35Sq.mm. 215 Pumping Plant Motor inspection, B&Į and Challan fee 216 MOTORCONTROLCENTER(MCC)PANEL:-Single front, Indoor & floor mounted,cubical type Panel factory fabricated (2 mm thick for sructure, 1.6mm thick for door,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coateddust and vermin proof IP-54 / IS:2147, considered Earth Bus-Bar-GI Strip compitable to SCADA operation with RS485 Port consisting of63 A, 50KA, TPN, MCCB microprocessor baseed(O/C,S/C) release - 1 No , Spreader Įinks & Extended ROH for - 1 No, 3 Phase Digital Multifunction Meter- 1 No, Digital Voltmeter 0-500V- 1 No, Digital Ammeter 0-400A-1Nos,CTFormeterResinCastCĮ-1400A/5A,15VA-3Nos,Phase indication light ĮED type 220V AC - 1 Set, Control MCB SP 6A ,10KA - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Įink - 1 No. 217 Supply of Air Cooled Digital soft starter suitable for the ĮT motor offered for operation in AC three Phase 50Hz (+/- 5%), 415V(+/-10%) including line contactors suitable for next standard higher KW rating, Over & Under load protection, short circuit & single phasing protection with frequency meter, Ammeter,Voltmeter,indicatinglamp6Nos, ĮED ON/OFF type and Start/StoppushbuttonandInstrumentFuses,suitabletoSCADAoperation with RS485 Port of rating capacity 25HP/18.50KW 218 Supplyofmicroprocessorbasedthreephasesensingpowerfactor correctionrelaypanel,IEC/EN61000-6-(2&4)having3CTsensing, sensitivity up to 50 milli amp secondary current , self analysing auto c/k setting according to targeted powerfactor setting, the relay shall have digit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current, insufficient compensation, communication interface with RS 485, indication of switching on units, auto/manual status, and shall have over load protection, no volt release , having multiparameterlike KW, KVA, KVAR rating capacity of 25KVAR 219 Supply of Servo Controlled Automatic Voltage stabilizer suitable for out put voltage of 415 Volt +/-1%, 3 Ph, 50 Hz, with copper wound transformer (air/oilcooled).Thestabilizer shall functionsatisfactorily evenif incoming supply is unbalanced between phases within range of 10%. The stabilizer should be constructed in cubical box, with bi-directional wheels for easy handling, necessary monitors and users controls on front panel such as indication, alarm, volt meter and selector switch for measuring input and out put voltage, Auto/Manual selector switch, Raise/Įow push buttonsetc.Suitable capacity termination stripsandbusbars for incoming and out going cable should be provided. All three phases shall beindependentlymonitoredandcorrected(Operatingvoltage240V- 500V), 415 volt, 3Phase, 50Hz of following capacity of 40KVA 220 Supply of Change over or by pass switch rating capacity 63Amp 221 Supply of 2 Ton 4.5 mtr lift chain pully block 222 SupplyofAutophasereversalunit with inbuilttimedelay& enclosure (conforming to IEC:60947-1 & IEC:60947-b-1) 63Amprating 223 Supply of CE/UĮ Certified Surge protector for control panel 224 Providing & Fixing of IK07 IP-66 protected high power ĮED flood light system with Pressure diecast aluminium housing ĮM6/ ADC12 material 50 Watt Flood light 225 SupplyofAutomatic/SCADAoperatedelectromegnaticchlorination dozzer system 226 INSTRUMENTATIONWORK 227 Supply of CE/UĮ Certified pressure transmitter CE markd with following technical parametersand Interfacing with PĮC panel including mounting arrangement.Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4 ĮEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 228 SupplyofCE/UĮCertifiedFullBoreElectromagneticFlowMeterof approved make of following dia and specifications complete: Media: Water (Raw/Chlorinated) , Pressure :up to 1.0MPa, Process temp:-50degC, Flow/MeterTube:SS304, Electrode:SSAISI 316Į /Hastelloy C276/Tantalum,ĮiningMaterial:HardRubber/ Neoprene/Poly-urethane(PU) , Flange : SS /CS, Flange Standard & Rating:ANSI150,Coilhousing:SSAISI304/CarbonSteel/DieCast Aluminium,with anticorrosive paint & provide completelysealed(leak proof)constructionasperrequirement‘ofIEC 60529, Accuracy : + 0.5% M.V.- velocity 0.3 to 10 m/s, Transmitter/ signa convertorEnclosure: Die CastAluminium,Power Supply : 80-240V AC - 5OHz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart,Display Type: ĮCD/ ĮED Display,Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable, of100mmdia sizeatoutle. 229 CE & UĮ Certified PĮC/ RTU in IP 54 enclosure suitable to communicate with intelligent GSM Based modem unit with CPU and Power Supply with analogandDigitalParameterandfeaturesasspecified tostoreand transmit data on GSM backbone, RTU designed with logic to tansfer data atmultiplestationsandalsocompatibleforsatellitecommunication alongwithcontrolpanelwithIP54Protection,Industrialgradeforall equipment and 24V and power supply for Tubewell & OHT 230 GSM/GPRS based wireless communication with 4G modem for RTU/PĮC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer, antenna made for pumping plantwith SIM andrecharge for 1 year 231 Supply of CE/UĮ cirtified of Radar type level transmitter CE marked with following technical parameters and Interfacing with PĮC panel including mounting arrangement with inbuild battery of 5 year life forOHTOutput-4-20 mA / HART Power supply - 24V DC ext. Display - 4 ĮEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 232 CE&UĮCertified7 HMItouchscreensuitabletocommunicationwith PĮC/RTU for local display & control of process parameters 233 CE/UĮ Certified Intelligent energy meters 234 SupplyofElectricallyMotoroperatedactuatorwithbracketfor sluice valve suitable for SCADA operation with limit switches, auto de clutch for manual operation in emergency etcas per relevant IS suitable for 300 mmdia sizesluice valveat OHT outlet 235 Completecablingforinstrumentation/SCADAequipmentswithpower supply of panels form source for Tubewell & OHT 236 Security Survelliance IP Camera with all required accessories 237 Supply and Fixing of fire extinguisher of 5 Kg. capacity conforming to IS: 15683:2006 238 Rubber mats for electrical purpose as per IS:5425-1969, plain/chequered (1mX2m) - 19mm thickness 239 Installation,testing and comissioning of pumpingplant & associated all equipmentsas per approveddrawing shall be done by bidder including electrical resistance rubber mats and painting of pumping plant & main piping-valves. 240 Testing of Pumping Plant & Control Panel & valves etc at Manufacturer Works 241 CLEARWATERSUBMERSIBLEPUMPINGPLANTFORTUBEWELLSTOCWRZONE-2 242 Supply,installation,testingandcommissioningofClearwater submersiblepump(IS9236)completewithelectricmotor(IS8034) capable to operate on 380/420 volts 3 phase 50 c/s A.C. Capable for giving 800LPM,46MtrHead,20HPforExsistingTubewell . 243 Supply,installation,testingandcommissioningofClearwater submersiblepump(IS9236)completewithelectricmotor(IS8034) capable to operate on 380/420 volts 3 phase 50 c/s A.C. Capable for giving 900LPM,46MtrHead,20HPfor05Nos.NewTube well. 244 Supply,installation,testing andcommissioningof Main Piping & Valves with24Mtr.Columnpipe,bend,Tee,powerwiring,earthing,painting, wiring of pump house (Internal & External)complete in all respect with all required material, T&P labour 100mmDia.size . 245 Supply of 3 Mtr Įong Heavy duty exta Coloum pipe 100 mm Dia. Size (8 No for each TW ) 246 Supply of Motor operated actuators forsluice valve suitable for SCADA operationwithlimitswitches,autodeclutchformanualoperationin emergencyetcasperrelevantISsuitablefor100 mm dia size sluice valve 247 Supply of D.I./ D.F. Dismantling Joints is a variable length Double Flanged ShortPiececonstitutedbya flange/ SpigotTailpieceinsertedintothe other Tailpiece which allows the distance between the two flanges to be variedwithincertainlimitsthusprovidingavariabledistancepiece betweentwofixedflangeenddeviceslikePumpsandValves.The Dismantling Joint to be supplied complete with Sealing Rubber Gaskets of EPDM quality (IS:5382/1985 Type-4), Cast Iron Follower Glands and Mild Steel (Zinc Coated) Nut Bolts of 100mm diasize 248 ExtraSubmersibleflatcoppercondutorcable3Cx6sq.mmPVC Sheathed double run (2Rx30m = 60 mtr for each TW) 249 Supply& laying of Į.T. XĮPE insulatedarmouredaluminiumconductor cable of 1.1 KV grade Material :- H4- Grade aluminium conductor of purity>99.6%&asperIS:1554P-I/IS:7098P-(I),conductorshallhave electrolytic aluminium confirming to IS 8130, IS 3975-1999.From transformer to Main ĮT panel of 3.5Cx 35Sq.mm. 250 Pumping Plant Motor inspection, B&Į and Challan fee 251 MOTORCONTROLCENTER(MCC)PANEL:-Single front, Indoor & floor mounted,cubical type Panel factory fabricated (2 mm thick for sructure, 1.6mm thick for door,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coateddust and vermin proof IP-54 / IS:2147, considered Earth Bus-Bar-GI Strip compitable to SCADA operation with RS485 Port consisting of63 A, 50KA, TPN, MCCB microprocessor baseed(O/C,S/C) release - 1 No , Spreader Įinks & Extended ROH for - 1 No, 3 Phase Digital Multifunction Meter- 1 No, Digital Voltmeter 0-500V- 1 No, Digital Ammeter 0-400A-1Nos,CTFormeterResinCastCĮ-1400A/5A,15VA-3Nos,Phase indication light ĮED type 220V AC - 1 Set, Control MCB SP 6A ,10KA - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Įink - 1 No. 252 Supply of Air Cooled Digital soft starter suitable for the ĮT motor offered for operation in AC three Phase 50Hz (+/- 5%), 415V(+/-10%) including line contactors suitable for next standard higher KW rating, Over & Under load protection, short circuit & single phasing protection with frequency meter, Ammeter,Voltmeter,indicatinglamp6Nos, ĮED ON/OFF type and Start/StoppushbuttonandInstrumentFuses,suitabletoSCADAoperation with RS485 Port of rating capacity 20HP/15KW 253 Supplyofmicroprocessorbasedthreephasesensingpowerfactor correctionrelaypanel,IEC/EN61000-6-(2&4)having3CTsensing, sensitivity up to 50 milli amp secondary current , self analysing auto c/k setting according to targeted powerfactor setting, the relay shall have digit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current, insufficient compensation, communication interface with RS 485, indication of switching on units, auto/manual status, and shall have over load protection, no volt release , having multiparameterlike KW, KVA, KVAR rating capacity of 20KVAR 254 Supply of Servo Controlled Automatic Voltage stabilizer suitable for out put voltage of 415 Volt +/-1%, 3 Ph, 50 Hz, with copper wound transformer (air/oilcooled).Thestabilizer shall functionsatisfactorily evenif incoming supply is unbalanced between phases within range of 10%. The stabilizer should be constructed in cubical box, with bi-directional wheels for easy handling, necessary monitors and users controls on front panel such as indication, alarm, volt meter and selector switch for measuring input and out put voltage, Auto/Manual selector switch, Raise/Įow push buttonsetc.Suitable capacity termination stripsandbusbars for incoming and out going cable should be provided. All three phases shall beindependentlymonitoredandcorrected(Operatingvoltage240V- 500V), 415 volt, 3Phase, 50Hz of30KVA capacity 255 Supply of Change over or by pass switch rating capacity 63Amp 256 Supply of 2 Ton 4.5 mtr lift chain pully block 257 SupplyofAutophasereversalunit with inbuilttimedelay& enclosure (conforming to IEC:60947-1 & IEC:60947-b-1) 63Amprating 258 Supply of CE/UĮ Certified Surge protector for control panel 259 Providing & Fixing of IK07 IP-66 protected high power ĮED flood light system with Pressure diecast aluminium housing ĮM6/ ADC12 material 50 Watt Flood light 260 INSTRUMENTATIONWORK 261 Supply of CE/UĮ Certified pressure transmitter CE markd with following technical parametersand Interfacing with PĮC panel including mounting arrangement.Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4 ĮEDAccuracy - +/- 0.1 % of full scale or betterEnclosure- IP 68 262 SupplyofCE/UĮCertifiedFullBoreElectromagneticFlowMeterof approved make of following dia and specifications complete: Media: Water (Raw/Chlorinated) , Pressure :up to 1.0MPa, Process temp:-50degC, Flow/MeterTube:SS304, Electrode:SSAISI 316Į /Hastelloy C276/Tantalum,ĮiningMaterial:HardRubber/ Neoprene/Poly-urethane(PU) , Flange : SS /CS, Flange Standard & Rating:ANSI150,Coilhousing:SSAISI304/CarbonSteel/DieCast Aluminium,with anticorrosive paint & provide completelysealed(leak proof)constructionasperrequirement‘ofIEC 60529, Accuracy : + 0.5% M.V.- velocity 0.3 to 10 m/s, Transmitter/ signa convertorEnclosure: Die CastAluminium,Power Supply : 80-240V AC - 5OHz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart,Display Type: ĮCD/ ĮED Display,Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable, of100mmdia size at delivery header 263 CE & UĮ Certified PĮC/ RTU in IP 54 enclosure suitable to communicate with intelligent GSM Based modem unit with CPU and Power Supply with analogandDigitalParameterandfeaturesasspecified tostoreand transmit data on GSM backbone, RTU designed with logic to tansfer data atmultiplestationsandalsocompatibleforsatellitecommunication alongwithcontrolpanelwithIP54Protection,Industrialgradeforall equipment and 24V and power supply for Tubewell 264 GSM/GPRS based wireless communication with 4G modem for RTU/PĮC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer, antenna made for pumping plantwith SIM andrecharge for 1 year 265 CE&UĮCertified7 HMItouchscreensuitabletocommunicationwith PĮC/RTU for local display & control of process parameters 266 CE/UĮ Certified Intelligent energy meters 267 Completecablingforinstrumentation/SCADAequipmentswithpower supply of panels form source for Tubewell 268 Security Survelliance IP Camera with all required accessories 269 Supply and Fixing of fire extinguisher of 5 Kg. capacity conforming to IS:15683:2006 270 Rubber mats for electrical purpose as per IS:5425-1969, plain/chequered (1mX2m) - 19mm thickness 271 Installation,testing and comissioning of pumpingplant & associated all equipmentsas per approveddrawing shall be done by bidder including electrical resistance rubber mats and painting of pumping plant & main piping-valves. 272 Testing of Pumping Plant & Control Panel & valves etc at Manufacturer Works 273 CLEARWATERSUBMERSIBLEPUMPINGPLANTFORTUBEWELLSTOCWRZONE-3 274 Supply,installation,testingandcommissioningofClearwater submersiblepump(IS9236)completewithelectricmotor(IS8034) capable to operate on 380/420 volts 3 phase 50 c/s A.C. Capable for giving 800LPM,46MtrHead,20 HPforExsistingTubewell. 275 Supply,installation,testingandcommissioningofClearwater submersiblepump(IS9236)completewithelectricmotor(IS8034) capable to operate on 380/420 volts 3 phase 50 c/s A.C. Capable for giving 900LPM,46MtrHead,20HPfor05Nos.New Tube well . 276 Supply,installation,testing andcommissioningof Main Piping & Valves with24Mtr.Columnpipe,bend,Tee,powerwiring,earthing,painting, wiring of pump house (Internal & External)complete in all respect with all required material, T&P labour 100mmDia.size. 277 Supply of 3 Mtr Įong Heavy duty exta Coloum pipe 100 mm Dia. Size (8 No for each TW ) 278 Supply of Motor operated actuators forsluice valve suitable for SCADA operationwithlimitswitches,autodeclutchformanualoperationin emergencyetcasperrelevantISsuitablefor100 mm dia size sluice valve 279 Supply of D.I./ D.F. Dismantling Joints is a variable length Double Flanged ShortPiececonstitutedbya flange/ SpigotTailpieceinsertedintothe other Tailpiece which allows the distance between the two flanges to be variedwithincertainlimitsthusprovidingavariabledistancepiece betweentwofixedflangeenddeviceslikePumpsandValves.The Dismantling Joint to be supplied complete with Sealing Rubber Gaskets of EPDM quality (IS:5382/1985 Type-4), Cast Iron Follower Glands and Mild Steel (Zinc Coated) Nut Bolts of 100mm diasize 280 ExtraSubmersibleflatcoppercondutorcable3Cx6sq.mmPVC Sheathed double run (2Rx30m = 60 mtr for each TW) 281 Supply& laying of Į.T. XĮPE insulatedarmouredaluminiumconductor cable of 1.1 KV grade Material :- H4- Grade aluminium conductor of purity>99.6%&asperIS:1554P-I/IS:7098P-(I),conductorshallhave electrolytic aluminium confirming to IS 8130, IS 3975-1999.From transformer to Main ĮT panel of 3.5Cx 35Sq.mm. 282 Pumping Plant Motor inspection, B&Į and Challan fee 283 MOTORCONTROLCENTER(MCC)PANEL:-Single front, Indoor & floor mounted,cubical type Panel factory fabricated (2 mm thick for sructure, 1.6mm thick for door,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coateddust and vermin proof IP-54 / IS:2147, considered Earth Bus-Bar-GI Strip compitable to SCADA operation with RS485 Port consisting of63 A, 50KA, TPN, MCCB microprocessor baseed(O/C,S/C) release - 1 No , Spreader Įinks & Extended ROH for - 1 No, 3 Phase Digital Multifunction Meter- 1 No, Digital Voltmeter 0-500V- 1 No, Digital Ammeter 0-400A-1Nos,CTFormeterResinCastCĮ-1400A/5A,15VA-3Nos,Phase indication light ĮED type 220V AC - 1 Set, Control MCB SP 6A ,10KA - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Įink - 1 No. 284 Supply of Air Cooled Digital soft starter suitable for the ĮT motor offered for operation in AC three Phase 50Hz (+/- 5%), 415V(+/-10%) including line contactors suitable for next standard higher KW rating, Over & Under load protection, short circuit & single phasing protection with frequency meter, Ammeter,Voltmeter,indicatinglamp6Nos, ĮED ON/OFF type and Start/StoppushbuttonandInstrumentFuses,suitabletoSCADAoperation with RS485 Port of rating capacity 20HP/15KW 285 Supplyofmicroprocessorbasedthreephasesensingpowerfactor correctionrelaypanel,IEC/EN61000-6-(2&4)having3CTsensing, sensitivity up to 50 milli amp secondary current , self analysing auto c/k setting according to targeted powerfactor setting, the relay shall have digit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current, insufficient compensation, communication interface with RS 485, indication of switching on units, auto/manual status, and shall have over load protection, no volt release , having multiparameterlike KW, KVA, KVAR rating capacity of 20KVAR 286 Supply of Servo Controlled Automatic Voltage stabilizer suitable for out put voltage of 415 Volt +/-1%, 3 Ph, 50 Hz, with copper wound transformer (air/oilcooled).Thestabilizer shall functionsatisfactorily evenif incoming supply is unbalanced between phases within range of 10%. The stabilizer should be constructed in cubical box, with bi-directional wheels for easy handling, necessary monitors and users controls on front panel such as indication, alarm, volt meter and selector switch for measuring input and out put voltage, Auto/Manual selector switch, Raise/Įow push buttonsetc.Suitable capacity termination stripsandbusbars for incoming and out going cable should be provided. All three phases shall beindependentlymonitoredandcorrected(Operatingvoltage240V- 500V), 415 volt, 3Phase, 50Hz of30KVA capacity 287 Supply of Change over or by pass switch rating capacity 63Amp 288 Supply of 2 Ton 4.5 mtr lift chain pully block 289 SupplyofAutophasereversalunit with inbuilttimedelay& enclosure (conforming to IEC:60947-1 & IEC:60947-b-1) 63Amprating 290 Supply of CE/UĮ Certified Surge protector for control panel 291 Providing & Fixing of IK07 IP-66 protected high power ĮED flood light system with Pressure diecast aluminium housing ĮM6/ ADC12 material 50 Watt Flood light 292 INSTRUMENTATIONWORK 293 Supply of CE/UĮ Certified pressure transmitter CE markd with following technical parametersand Interfacing with PĮC panel including mounting arrangement.Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4 ĮEDAccuracy - +/- 0.1 % of full scale or betterEnclosure- IP 68 294 SupplyofCE/UĮCertifiedFullBoreElectromagneticFlowMeterof approved make of following dia and specifications complete: Media: Water (Raw/Chlorinated) , Pressure :up to 1.0MPa, Process temp:-50degC, Flow/MeterTube:SS304, Electrode:SSAISI 316Į /Hastelloy C276/Tantalum,ĮiningMaterial:HardRubber/ Neoprene/Poly-urethane(PU) , Flange : SS /CS, Flange Standard & Rating:ANSI150,Coilhousing:SSAISI304/CarbonSteel/DieCast Aluminium,with anticorrosive paint & provide completelysealed(leak proof)constructionasperrequirement‘ofIEC 60529, Accuracy : + 0.5% M.V.- velocity 0.3 to 10 m/s, Transmitter/ signa convertorEnclosure: Die CastAluminium,Power Supply : 80-240V AC - 5OHz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart,Display Type: ĮCD/ ĮED Display,Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable, of100mmdia size at delivery header 295 CE & UĮ Certified PĮC/ RTU in IP 54 enclosure suitable to communicate with intelligent GSM Based modem unit with CPU and Power Supply with analogandDigitalParameterandfeaturesasspecified tostoreand transmit data on GSM backbone, RTU designed with logic to tansfer data atmultiplestationsandalsocompatibleforsatellitecommunication alongwithcontrolpanelwithIP54Protection,Industrialgradeforall equipment and 24V and power supply for Tubewell 296 GSM/GPRS based wireless communication with 4G modem for RTU/PĮC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer, antenna made for pumping plantwith SIM andrecharge for 1 year 297 CE&UĮCertified7 HMItouchscreensuitabletocommunicationwith PĮC/RTU for local display & control of process parameters 298 CE/UĮ Certified Intelligent energy meters 299 Completecablingforinstrumentation/SCADAequipmentswithpower supply of panels form source for Tubewell 300 Security Survelliance IP Camera with all required accessories 301 Supply and Fixing of fire extinguisher of 5 Kg. capacity conforming to IS:15683:2006 302 Rubber mats for electrical purpose as per IS:5425-1969, plain/chequered (1mX2m) - 19mm thickness 303 Installation,testing and comissioning of pumpingplant & associated all equipmentsas per approveddrawing shall be done by bidder including electrical resistance rubber mats and painting of pumping plant & main piping-valves. 304 Testing of Pumping Plant & Control Panel & valves etc at Manufacturer Works 305 CLEARWATERPUMPINGPLANTATPROPOSEDCWR(575 KL)ZONE -2TO PROPOSEDOHT(1600 KL)ZONE-2 306 SupplyofVerticaltypeself-waterlubricatedstatically, dynamically, hydraulically balanced turbinepump capable of dischargingat1450rpmthefollowingdutyconditionasgiven below due to all causes with surface discharge head confirming to IS:1710andasamendedasondatewithaccessoriesasperIS 5120/1977(Reconfirmed 2011) and as amended thereafter to suit the site condition.The Pump Bowl assemblyshall be FG: 260with 2% NiCi with CF8M impeller running at 1450 rpm., head shaft, SS line shaft, Rubberlineshaftbearing,C.I.Bearingretainer,Suction bell mouth, strainer, 5 mtr/suitable length column assembly, with vertical Solid shaft Squirrel cage induction motor(IS:126152011/IEC 60034-1) suitable for the above pump continuous rated TEFC IP-55 with ClassF insulationfor operationin AC, threePhase/50HZ (±5%), 415V (±10%), running with a speed of pump.CAPACITY:-3050LPM/36Mtr.HEAD /40HPMOTOR(2w+1s) 307 MAINPIPINGAND VALVES:- 308 SupplyofCIDFSingleDoor/MultiDoorNonreturn/refluxvalve conformingtoIS:5312/2003(partI&II)PN-1.0tobefixedafter pumps for 90% fast closing & 10% slow closing of 200mmdiasize 309 Supply of CIDFElectrically integrated actuater (Totally enclosed, weather-proof and dust proof construction with IP-67, protection class suitable for installationin any positionwithout lubrication, leakageorotheroperationaldifficultywithspecialgreasefilled gear box and suitable for manual operation for emergency which willautomaticallydis-engageonrestorationofpowertomotor and with 10 watt single phase space heater and continuous local mechanical position indicator and individually replaceable counter gear assembly and with two torque and four limit switches withS.S. flapandoperatedwith geardriven camsandof rating250 Volt, 5 Amp, AC/DC, torque switch dial and with TEFC squirrel cage induction)operatedsuitabletoSCADAoperationsluicevalve having body door cover of graded in cast iron to IS:210 Gr.Fg.260 body and door rings of SS ASTM A743 Gr.CF8 and bearing block of leadedtinbronzetoIS:318Gr.ĮTB2hingepinofstainlesssteel AISI:431.Valves generally conform to IS:5312.Flanges tobedrilled asperIS:1538Part-IV&VI. Valves aresuitable for hydrostatic test pressure of 10Kg./Cm2 for seat and 15Kg./Cm2 for body(PN- 1.0) of200mmat pumpdelivery 310 Supply of CIDFmanually operated sluice valve having body door coverofgradedincastirontoIS:210Gr.Fg.260bodyanddoor ringsofSSASTMA743Gr.CF8andbearingblockofleadedtin bronzetoIS:318Gr.ĮTB2hingepinofstainlesssteel AISI:431.Valves generally conform to IS:5312.Flanges tobedrilled asperIS:1538Part-IV&VI. Valves aresuitable for hydrostatic test pressure of 10Kg./Cm2 for seat and 15Kg./Cm2 for body(PN-1.0 Rating) Sluice Valve of300mm at Commonheader&bypass 311 SupplyofElectricallyMotoroperatedactuatorwithbracketfor sluice valve suitable for SCADA operation with limit switches, auto de clutch for manual operation in emergency etcas per relevant IS suitable for 450mmdiasizeforOHToutlet 312 Supplyandfabricationofmainpiping1mtroutsidethepump houseoffollowingsizes300 x 200 x 300 mm MS D/F Tee (10 mm thickness) -3 No200 mm MS D/F Pipe 0.50 mt. (10 mm thickness) - 3 No 200 mm MS D/F Pipe 1.00 mt.(10 mm thickness) - 3 No 300 mm MS D/F Pipe 1.00 mt.(10 mm thickness) - 3 No 300 mm MS D/F Pipe 2.00 mt. (10 mm thickness) -2 No 300 mm MS D/F (10 mm thickness) Bend 90o- 2 No 300 mm Blind Flange - 1 NoNecessary GI Nut Bolt’s & Rubber Packing - 1 Įot 313 Supply of D.I./ D.F. Dismantling Joints is a variable length Double FlangedShortPiececonstitutedbyaflange/SpigotTailpiece insertedintotheotherTailpiece whichallows thedistance betweenthetwoflangestobevariedwithincertainlimitsthus providing a variable distance piece between two fixed flange end deviceslikePumpsandValves.TheDismantlingJointtobe supplied complete with Sealing Rubber Gaskets of EPDM quality (IS:5382/1985Type-4),CastIronFollowerGlands andMild Steel (Zinc Coated) Nut Bolts of Following size 314 Dismantling joint 200 mm dia size at pump delivery 315 Dismantling joint 300 mm dia size at common header 316 3Ton capacity hand operated over head Travelling (HOT) crane H- Typesuitablefor a spanupto6 Mtrs, andtravellengthupto10 Mtrs. with clear lift upto 6 M including gear type chain pulley block and geared Travelling trolley complete with all accessories including girder. 317 MOTORCONTROLCENTER(MCC)PANEL:-Singlefront,Indoor&floormounted,cubicaltypePanelfactory fabricated (2 mm thick for sructure, 1.6mm thick for door,covers shroudsandGlandPlate-3mmthick)CRCAsheetdulypower coated dustandverminproofIP-54/IS:2147,consideredEarth Bus-Bar-GI Strip compitable to SCADA operation with RS485 Port consisting ofINCOMMINGSECTION320 A, 50KA, TPN, MCCB microprocessor baseed (O/C,S/C) release-1No,SpreaderĮinks&ExtendedROHfor-1No,3 Phase Digital Multifunction Meter- 1 No, Digital Voltmeter 0-500V- 1 No, Digital Ammeter 0-400A- 1 Nos, CT For meter Resin Cast CĮ-1400A/5A,15VA - 3 Nos, Phase indication light ĮED type 220V AC - 1 Set, Control MCB SP 6A ,10KA - 3 Nos, CT Shorting Terminal 4 Nos, Neutral Įink - 1 No.OUTGOINGSECTION100 A, 50KA, TPN, MCCBmicroprocessor based (O/C,S/C) REĮEASE - 4 No, Spreader Įinks & Extended ROH for MCCB - 4 Nos., 63A TPN MCCB 35KA- 3 Nos. Terminal 63A 318 Supply of Air Cooled Digital soft starter suitable for the ĮT motor offered for operationin AC three Phase 50Hz (+/- 5%), 415V(+/- 10%)includinglinecontactorssuitablefornextstandardhigher KWrating,Over&Underloadprotection,shortcircuit&single phasingprotectionwithfrequencymeter,Ammeter,Voltmeter, indicatinglamp6Nos,ĮEDON/OFFtypeandStart/Stoppush buttonandInstrumentFuses,suitabletoSCADAoperationwith RS485 Port of rating capacity 40HP/30KW 319 Supplyofmicroprocessorbasedthreephasesensingpower factor correction relay panel , IEC / EN 61000-6- (2&4) having 3 CT sensing,sensitivityupto50milliampsecondarycurrent,self analysingautoc/ksettingaccordingtotargetedpowerfactor setting, the relay shall have digit display unit for displayof real power factor, targeted power factor, lag/lead capacitor switching status, alarmoutput for under current, over current, insufficient compensation, communication interface with RS 485, indication of switching on units, auto/manual status, and shall have over load protection, no volt release , having multi parameter like KW, KVA, KVAR rating capacity of 40KVAR 320 Supply & laying of 1.1 KV grade XĮPE insulatedun armoured multi strandcopperconductorcableof3C x 25 sq.mm fromcontrol PaneltorespectiveMotorswithlugsetc.(copperconductor should be electrlytic grade coppe, purity >99.97 % ISI markedas per IS:1554 P-I / IS:7098 P- I) 321 Supply &Fixing ofPowder coated GI Cable Tray 150mmx50mmx1.6mm 322 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick includingaccessories,andprovidingmasonryenclosurewith cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required according to latest IS:3043 323 Supplying and laying 50 mm X 6 mm GI strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done byoverlappingandwith2 sets of brassnut bolt& spring washer spaced at 50mm) 324 Supply of ABC Dry Powder type Fire Extinguisher 4.5 kg conforming to IS: 15683:2006 325 Supply of Auto Phase reversal unit / Automatic switch with inbuilt the delay & enclosure (Confirms to IEC: 60947-1 & IEC: 60947-6-1) of 250Amp 326 S& F of all in one solar ĮED street light fixture with Integrated high efficientMonocrystallinepanel withĮithium(ĮiFePO4)Ferro Phosphate battery with BIS approved make .luminaire should be secondaryopticlensesforbetterdistributionwithdelivered efficacy of >100 Įumen per watt. Įuminaire can be supplied with Hybridswitchalongwithindicatortounderstandthesourceof power(eitherfromsolarorACsupply).shallhavecertificate tested fromMNRE approved Įab. Guarantee for total system is two years .Note: All the aboveshould be integrated and should be 1 system.make:Bajaj/Philips/Crompton.CompactSolar LED StreetLight-60W/12V/27AhwithGIpole 327 Internal&ExternalelectrificationofPumphouse 328 Twin tube light covered ĮED 20 Watt 329 450 mm dia exhaust fan 330 Providing & Fixing of IK07 IP-66 protected high power ĮED flood light system with Pressure diecast aluminium housing ĮM6/ ADC12 material 50 Watt Flood light 331 CompletewiringofPumphousewith1.5Sqmm&2.5Sqmm multistarnd copper conductor wire 1.1 KV with required 5A & 15A switches, ceiling rose 332 Supply of CE/UĮ Certified Surge protector for control panel 333 Rubber mats for electrical purpose as per IS:5425-1969, plain/chequered (1mX2m) - 19mm thickness 334 SupplyofAutomatic/SCADAoperatedelectromegnatic chlorination dozzer system 335 INSTRUMENTATIONWORK 336 Supply of CE/UĮ certified Full bore Electromagnetic Flow Meter of approved make of following dia and specifications complete: Media : Water (Raw/Chlorinated) , Pressure : up to 1.0 MPa,Processtemp:-50degC, Flow/MeterTube:SS304, Electrode:SSAISI316Į/ HastelloyC276/Tantalum,Įining Material : Hard Rubber/ Neoprene/Poly-urethane(PU) , Flange : SS /CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/CarbonSteel/ DieCast Aluminium,with anticorrosive paint & provide completelysealed(leakproof)constructionas perrequirement‘ofIEC 60529, Accuracy : + 0.5 % M.V.- velocity0.3 to 10 m/s, Transmitter/ signa convertorEnclosure: Die Cast Aluminium,Power Supply : 80-240V AC - 5OHz, Output 1 : 4-20 mA,Output2:Pulse,CommunicationOutput:RS485/Heart, Display Type : ĮCD/ ĮED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibrationandconfigurationparameters and totalizer value during power failure, Protection category- IP 68forsensor(flowtube)andIP67fortransmitter/convertor, including Surge Arrester, cable, of300mm dia size at common header 337 SupplyofCE/UĮCertifiedpressuretransmitterCEmarkdwith followingtechnicalparameters andInterfacingwithPĮCpanel including mounting arrangement.Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4 ĮEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 338 SupplyofCE/UĮcirtifiedofRadartypeleveltransmitterCE marked with following technical parameters and Interfacing with PĮC panel including mounting arrangement forCWROutput-4-20 mA / HART Power supply - 24V DC ext. Display - 4 ĮEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 339 SupplyofCE/UĮcirtifiedofRadartypeleveltransmitterCE marked with following technical parametersand Interfacing with PĮC panel including mounting arrangement with inbuild battery of 5 year life forOHTOutput-4-20 mA / HART Power supply - 24V DC ext. Display - 4 ĮEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 340 CE&UĮCertifiedPĮC/RTUinIP54enclosuresuitableto communicatewithintelligentGSMBasedmodemunitwithCPU and Power Supply with analog and Digital Parameter and features as specified for each for each ZPS/OHT to store and transmit data onGSMbackbone,RTUdesignedwithlogictotansferdataat multiple stations and also compatible for satellite communication alongwith control panel with IP 54 Protection , Industrial grade for all equipment and 24V and power supply 341 GSM/GPRSbasedwirelesscommunicationwith4Gmodemfor RTU/PĮC Capable to transfer and gather data from remote sites to controlstationsallaccessoriesincludedwithsignalenhancer, antennamadeforpumpingplant withSIMand rechargefor1 year 342 CE&UĮCertifiedPĮC/RTUinIP54enclosuresuitableto communicatewithintelligentGSMBasedmodemunitwithCPU and Power Supply with analog and Digital Parameter and features as specified for each for each ZPS/OHT to store and transmit data onGSMbackbone,RTUdesignedwithlogictotansferdataat multiple stations and also compatible for satellite communication alongwith control panel with IP 54 Protection , Industrial grade for all equipment and 24V and power supply for OHT due to Outside the campus 343 GSM/GPRSbasedwirelesscommunicationwith4Gmodemfor RTU/PĮC Capable to transfer and gather data from remote sites to controlstationsallaccessoriesincludedwithsignalenhancer, antennamadeforpumpingplant withSIMand rechargefor1 year 344 CE & UĮ Certified 7 HMI touch screen suitable to communication with PĮC/RTU for local display & control of process parameters 345 CE/UĮ Certified Intelligent energy meters 346 Completecablingforinstrumentation/SCADAequipmentswith power supply of panels form source for CWR & OHT 347 Security Survelliance IP Camera with all required accessories 348 Toolset:-Spenners- 2 Nos,Adjustable Wrinch set - 2 Nos, size wrinches of different sizes - 1 Set, Gigital Tong tester - 1 Nos, Digital Clamp meter - 1 No, megger 5Mva- 1 No, Hydraulic crimping tool 500 Sq mmsize-1No,SandPPMmeasuringkit -1No,DigitalScrew Gauge 40mm size - 1 No, Inner & Outer pipe gauge set 500mm size-1Set, Fillergauges -1 Set,Electronic batteryoperatedwater level / depth gauge with meter marking upto 400 mtr depth - 1 No 349 Installation, testing and comissioning of pumping plant & associated all equipments as per approved drawing shall be done bybidderincludingchequerredplateandpaintingofpumping plant & main piping-valves. 350 Testing of Pumping Plant & Control Panel & valves etc at Manufacturer Works 351 CLEARWATERPUMPINGPLANTATPROPOSEDCWR(575 KL)ZONE-3TOPROPOSEDOHT(1750KL)ZONE-3 352 SupplyofVerticaltypeself-waterlubricatedstatically, dynamically, hydraulically balanced turbinepump capable of dischargingat1450rpmthefollowingdutyconditionasgiven below due to all causes with surface discharge head confirming to IS:1710andasamendedasondatewithaccessoriesasperIS 5120/1977(Reconfirmed 2011) and as amended thereafter to suit the site condition.The Pump Bowl assemblyshall be FG: 260with 2% NiCi with CF8M impeller running at 1450 rpm., head shaft, SS line shaft, Rubberlineshaftbearing,C.I.Bearingretainer,Suction bell mouth, strainer, 5 mtr/suitable length column assembly, with vertical Solid shaft Squirrel cage induction motor(IS:126152011/IEC 60034-1) suitable for the above pump continuous rated TEFC IP-55 with ClassF insulationfor operationin AC, threePhase/50HZ (±5%), 415V (±10%), running with a speed of pump.CAPACITY:-3250LPM/36Mtr.HEAD /40HPMOTOR(2w+1s) 353 MAINPIPINGAND VALVES:- 354 SupplyofCIDFSingleDoor/MultiDoorNonreturn/refluxvalve conformingtoIS:5312/2003(partI&II)PN-1.0tobefixedafter pumps for 90% fast closing & 10% slow closing of 200mmdiasize 355 Supply of CIDFElectrically integrated actuater (Totally enclosed, weather-proof and dust proof construction with IP-67, protection class suitable for installationin any positionwithout lubrication, leakageorotheroperationaldifficultywithspecialgreasefilled gear box and suitable for manual operation for emergency which willautomaticallydis-engageonrestorationofpowertomotor and with 10 watt single phase space heater and continuous local mechanical position indicator and individually replaceable counter gear assembly and with two torque and four limit switches withS.S. flapandoperatedwith geardriven camsandof rating250 Volt, 5 Amp, AC/DC, torque switch dial and with TEFC squirrel cage induction)operatedsuitabletoSCADAoperationsluicevalve having body door cover of graded in cast iron to IS:210 Gr.Fg.260 body and door rings of SS ASTM A743 Gr.CF8 and bearing block of leadedtinbronzetoIS:318Gr.ĮTB2hingepinofstainlesssteel AISI:431.Valves generally conform to IS:5312.Flanges tobedrilled asperIS:1538Part-IV&VI. Valves aresuitable for hydrostatic test pressure of 10Kg./Cm2 for seat and 15Kg./Cm2 for body(PN- 1.0) of200mmat pumpdelivery 356 Supply of CIDFmanually operated sluice valve having body door coverofgradedincastirontoIS:210Gr.Fg.260bodyanddoor ringsofSSASTMA743Gr.CF8andbearingblockofleadedtin bronzetoIS:318Gr.ĮTB2hingepinofstainlesssteel AISI:431.Valves generally conform to IS:5312.Flanges tobedrilled asperIS:1538Part-IV&VI. Valves aresuitable for hydrostatic test pressure of 10Kg./Cm2 for seat and 15Kg./Cm2 for body(PN-1.0 Rating) Sluice Valve of300mm at Commonheader&bypass 357 SupplyofElectricallyMotoroperatedactuatorwithbracketfor sluice valve suitable for SCADA operation with limit switches, auto de clutch for manual operation in emergency etcas per relevant IS suitable for 450mmdiasizeforOHToutlet 358 Supplyandfabricationofmainpiping1mtroutsidethepump houseoffollowingsizes300 x 200 x 300 mm MS D/F Tee (10 mm thickness) -3 No200 mm MS D/F Pipe 0.50 mt. (10 mm thickness) - 3 No 200 mm MS D/F Pipe 1.00 mt.(10 mm thickness) - 3 No 300 mm MS D/F Pipe 1.00 mt.(10 mm thickness) - 3 No 300 mm MS D/F Pipe 2.00 mt. (10 mm thickness) -2 No 300 mm MS D/F (10 mm thickness) Bend 90o- 2 No 300 mm Blind Flange - 1 NoNecessary GI Nut Bolt’s & Rubber Packing - 1 Įot 359 Supply of D.I./ D.F. Dismantling Joints is a variable length Double FlangedShortPiececonstitutedbyaflange/SpigotTailpiece insertedintotheotherTailpiece whichallows thedistance betweenthetwoflangestobevariedwithincertainlimitsthus providing a variable distance piece between two fixed flange end deviceslikePumpsandValves.TheDismantlingJointtobe supplied complete with Sealing Rubber Gaskets of EPDM quality (IS:5382/1985Type-4),CastIronFollowerGlands andMild Steel (Zinc Coated) Nut Bolts of Following size 360 Dismantling joint 200 mm dia size at pump delivery 361 Dismantling joint 300 mm dia size at common header 362 3Ton capacity hand operated over head Travelling (HOT) crane H- Typesuitablefor a spanupto6 Mtrs, andtravellengthupto10 Mtrs. with clear lift upto 6 M including gear type chain pulley block and geared Travelling trolley complete with all accessories including girder. 363 MOTORCONTROLCENTER(MCC)PANEL:-Singlefront,Indoor&floormounted,cubicaltypePanelfactory fabricated (2 mm thick for sructure, 1.6mm thick for door,covers shroudsandGlandPlate-3mmthick)CRCAsheetdulypower coated dustandverminproofIP-54/IS:2147,consideredEarth Bus-Bar-GI Strip compitable to SCADA operation with RS485 Port consisting ofINCOMMINGSECTION320 A, 50KA, TPN, MCCB microprocessor baseed (O/C,S/C) release-1No,SpreaderĮinks&ExtendedROHfor-1No,3 Phase Digital Multifunction Meter- 1 No, Digital Voltmeter 0-500V- 1 No, Digital Ammeter 0-400A- 1 Nos, CT For meter Resin Cast CĮ-1400A/5A,15VA - 3 Nos, Phase indication light ĮED type 220V AC - 1 Set, Control MCB SP 6A ,10KA - 3 Nos, CT Shorting Terminal 4 Nos, Neutral Įink - 1 No.OUTGOINGSECTION100 A, 50KA, TPN, MCCBmicroprocessor based (O/C,S/C) REĮEASE - 4 No, Spreader Įinks & Extended ROH for MCCB - 4 Nos., 63A TPN MCCB 35KA- 3 Nos. Terminal 63A 364 Supply of Air Cooled Digital soft starter suitable for the ĮT motor offered for operationin AC three Phase 50Hz (+/- 5%), 415V(+/- 10%)includinglinecontactorssuitablefornextstandardhigher KWrating,Over&Underloadprotection,shortcircuit&single phasingprotectionwithfrequencymeter,Ammeter,Voltmeter, indicatinglamp6Nos,ĮEDON/OFFtypeandStart/Stoppush buttonandInstrumentFuses,suitabletoSCADAoperationwith RS485 Port of rating capacity 40HP/30KW 365 Supplyofmicroprocessorbasedthreephasesensingpower factor correction relay panel , IEC / EN 61000-6- (2&4) having 3 CT sensing,sensitivityupto50milliampsecondarycurrent,self analysingautoc/ksettingaccordingtotargetedpowerfactor setting, the relay shall have digit display unit for displayof real power factor, targeted power factor, lag/lead capacitor switching status, alarmoutput for under current, over current, insufficient compensation, communication interface with RS 485, indication of switching on units, auto/manual status, and shall have over load protection, no volt release , having multi parameter like KW, KVA, KVAR rating capacity of 40KVAR 366 Supply & laying of 1.1 KV grade XĮPE insulatedun armoured multi strandcopperconductorcableof3C x 25 sq.mm fromcontrol PaneltorespectiveMotorswithlugsetc.(copperconductor should be electrlytic grade coppe, purity >99.97 % ISI markedas per IS:1554 P-I / IS:7098 P- I) 367 Supply &Fixing ofPowder coated GI Cable Tray 150mmx50mmx1.6mm 368 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick includingaccessories,andprovidingmasonryenclosurewith cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required according to latest IS:3043 369 Supplying and laying 50 mm X 6 mm GI strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done byoverlappingandwith2 sets of brassnut bolt& spring washer spaced at 50mm) 370 Supply of ABC Dry Powder type Fire Extinguisher 4.5 kg conforming to IS: 15683:2006 371 Supply of Auto Phase reversal unit / Automatic switch with inbuilt the delay & enclosure (Confirms to IEC: 60947-1 & IEC: 60947-6-1) of 250Amp 372 S& F of all in one solar ĮED street light fixture with Integrated high efficientMonocrystallinepanel withĮithium(ĮiFePO4)Ferro Phosphate battery with BIS approved make .luminaire should be secondaryopticlensesforbetterdistributionwithdelivered efficacy of >100 Įumen per watt. Įuminaire can be supplied with Hybridswitchalongwithindicatortounderstandthesourceof power(eitherfromsolarorACsupply).shallhavecertificate tested fromMNRE approved Įab. Guarantee for total system is two years .Note: All the aboveshould be integrated and should be 1 system.make:Bajaj/Philips/Crompton.CompactSolar LED StreetLight-60W/12V/27AhwithGIpole 373 Internal&ExternalelectrificationofPumphouse 374 Twin tube light covered ĮED 20 Watt 375 450 mm dia exhaust fan 376 Providing & Fixing of IK07 IP-66 protected high power ĮED flood light system with Pressure diecast aluminium housing ĮM6/ ADC12 material 50 Watt Flood light 377 CompletewiringofPumphousewith1.5Sqmm&2.5Sqmm multistarnd copper conductor wire 1.1 KV with required 5A & 15A switches, ceiling rose 378 Supply of CE/UĮ Certified Surge protector for control panel 379 Rubber mats for electrical purpose as per IS:5425-1969, plain/chequered (1mX2m) - 19mm thickness 380 SupplyofAutomatic/SCADAoperatedelectromegnatic chlorination dozzer system 381 INSTRUMENTATIONWORK 382 Supply of CE/UĮ certified Full bore Electromagnetic Flow Meter of approved make of following dia and specifications complete: Media : Water (Raw/Chlorinated) , Pressure : up to 1.0 MPa,Processtemp:-50degC, Flow/MeterTube:SS304, Electrode:SSAISI316Į/ HastelloyC276/Tantalum,Įining Material : Hard Rubber/ Neoprene/Poly-urethane(PU) , Flange : SS /CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/CarbonSteel/ DieCast Aluminium,with anticorrosive paint & provide completelysealed(leakproof)constructionas perrequirement‘ofIEC 60529, Accuracy : + 0.5 % M.V.- velocity0.3 to 10 m/s, Transmitter/ signa convertorEnclosure: Die Cast Aluminium,Power Supply : 80-240V AC - 5OHz, Output 1 : 4-20 mA,Output2:Pulse,CommunicationOutput:RS485/Heart, Display Type : ĮCD/ ĮED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibrationandconfigurationparameters and totalizer value during power failure, Protection category- IP 68forsensor(flowtube)andIP67fortransmitter/convertor, including Surge Arrester, cable, of300mm dia size at common header 383 SupplyofCE/UĮCertifiedpressuretransmitterCEmarkdwith followingtechnicalparameters andInterfacingwithPĮCpanel including mounting arrangement.Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4 ĮEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 384 SupplyofCE/UĮcirtifiedofRadartypeleveltransmitterCE marked with following technical parameters and Interfacing with PĮC panel including mounting arrangement forCWROutput-4-20 mA / HART Power supply - 24V DC ext. Display - 4 ĮEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 385 SupplyofCE/UĮcirtifiedofRadartypeleveltransmitterCE marked with following technical parametersand Interfacing with PĮC panel including mounting arrangement with inbuild battery of 5 year life forOHTOutput-4-20 mA / HART Power supply - 24V DC ext. Display - 4 ĮEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 386 CE&UĮCertifiedPĮC/RTUinIP54enclosuresuitableto communicatewithintelligentGSMBasedmodemunitwithCPU and Power Supply with analog and Digital Parameter and features as specified for each for each ZPS/OHT to store and transmit data onGSMbackbone,RTUdesignedwithlogictotansferdataat multiple stations and also compatible for satellite communication alongwith control panel with IP 54 Protection , Industrial grade for all equipment and 24V and power supply 387 GSM/GPRSbasedwirelesscommunicationwith4Gmodemfor RTU/PĮC Capable to transfer and gather data from remote sites to controlstationsallaccessoriesincludedwithsignalenhancer, antennamadeforpumpingplant withSIMand rechargefor1 year 388 CE&UĮCertifiedPĮC/RTUinIP54enclosuresuitableto communicatewithintelligentGSMBasedmodemunitwithCPU and Power Supply with analog and Digital Parameter and features as specified for each for each ZPS/OHT to store and transmit data onGSMbackbone,RTUdesignedwithlogictotansferdataat multiple stations and also compatible for satellite communication alongwith control panel with IP 54 Protection , Industrial grade for all equipment and 24V and power supply for OHT due to Outside the campus 389 GSM/GPRSbasedwirelesscommunicationwith4Gmodemfor RTU/PĮC Capable to transfer and gather data from remote sites to controlstationsallaccessoriesincludedwithsignalenhancer, antennamadeforpumpingplant withSIMand rechargefor1 year 390 CE & UĮ Certified 7 HMI touch screen suitable to communication with PĮC/RTU for local display & control of process parameters 391 CE/UĮ Certified Intelligent energy meters 392 Completecablingforinstrumentation/SCADAequipmentswith power supply of panels form source for CWR & OHT 393 Security Survelliance IP Camera with all required accessories 394 Installation, testing and comissioning of pumping plant & associated all equipments as per approved drawing shall be done bybidderincludingchequerredplateandpaintingofpumping plant & main piping-valves. 395 Testing of Pumping Plant & Control Panel & valves etc at Manufacturer Works 396 11/0.44KVSUBSTATIONATCWRZONE-2 397 Supply of star rated Copper wound distribution Transformer ( All the distribution transformer must be star rated as per notification of(BEE)ministryofpower,GoverenmentofIndia)offollowing rating11/0.433KVDelta-StarConnected,VectorGroupDyn11, ONAN Cooled & as per BEE star level- 2 & BIS approved as per IS 2026-1977 & losses as defined as per IS 1180 part (I) 2014 including standardaccessorieslikeconservator,silicagel breather,Bucholzrelay,radiator,fins,HTcablebox&ĮTcable boxes, Off -ĮTC (+7.5% to - 15% @ 2.5%) temperature rise of 40 degree C in oil / 45 degree C in winding , ISI marked drain valve, DialtypeTemperaturegauge,OTI&WTI,marshallingbox,first filling of transformer oil as per IS :335-1953, Epoxy based paint.Ratingcapacity-160KVA(1w+1s) 398 Supplyof11KV,630 A,25kA/1Sec, VCBIndoortypepanelHT board, free standing motor operated & withdrawal type fabricated from 2 mm thick CRCA sheet steel , With Ammeter, Voltmeter, PF Meter, KWH Meter, MDI Meter, Selector Switches as required, CRT CT of required ratio (15VA ; Cl-1.0 / 0.5 ) PT (11 KV /110V/√3) , Fuses, IP42 Protection,4 / 8 /10 / 12-window Annunciation Panel , AC/ DC Control voltage 24/48/ 110/230V , ĮED Indication lamps , S/C, O/C&E/FProtection(IDMT)RelaysAlarm&tripcontactsfor Transformer protection(High oil temperature, Buchholz protection,highwindingtemperature,powerpack2x12V,etc completeinallrespectreadytouse(RTU),OEMMusthaveBIS certificate incuding 1no incoming & 2 no outgoing VCB 399 External batteryand batterycharger of suitablerating having 1 Hrs backup for H.T. Panel 400 Supply and laying of 11/12KV grade XĮPE H.T. cable as per IS:7098/ II/85,H4- Grade aluminium conductor of purity >99.6 % & as per IS:1554 P-I / IS :7098 P - (I)from UPPCĮmetering panel to H.T. Switch gear panel and panel to transformers 95Sq.mm.size 401 Supply of H.T. Cable end termination heat shrinkable type indoor joint kit 95sq.mm. 402 Supply of H.T. Cable end termination heat shrinkable type outdoor joint kit 95sq.mm. 403 Supply&layingofĮ.T.XĮPEinsulated armouredaluminium conductorcable of 1.1 KV grade Material :- H4- Grade aluminium conductorofpurity>99.6%&asperIS:1554P-I/IS:7098P- (I),conductorshallhaveelectrolyticaluminiumconfirmingtoIS 8130, IS 3975-1999.From transformer to Main ĮT panel of 3.5Cx 150Sq.mm. 404 Single front, Indoor & floor mounted,cubical type ĮT Panel factory fabricated (2 mm thick for sructure, 1.6mm thick for door,covers shroudsandGlandPlate-3mmthick)CRCAsheetdulypower coateddust andverminproofIP-54/IS:2147,consideredEarth Bus-Bar-GIStripcompitabletoSCADAoperationwithRS485 Port consisting ofINCOMMINGSECTION320A,50KA,TPN,MCCB microprocessorbaseed (O/C,S/C) release - 2 No , SpreaderĮinks & Extended ROH for - 2 No, 3 Phase Digital Multifunction Meter- 1 No, Digital Voltmeter 0-500V- 1 No, Digital Ammeter 0-400A- 1 Nos, CT For meter Resin Cast CĮ-1400A/5A,15VA - 3 Nos, Phase indication light ĮED type 220V AC - 1 Set, Control MCB SP 6A ,10KA ABB - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Įink - 1 No.OUTGOINGSECTION320A,50KA,TPN,MCCB microprocessorbased(O/C,S/C) REĮEASE - 1 No, spreader Įinks & Extended ROH for MCCB - 1 Nos., 63A TPN MCCB 32KA- 2 Nos. Terminal 63A 405 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick includingaccessories,andprovidingmasonryenclosurewith cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required according to latest IS:3043 406 Supplying and laying 50 mm X 6 mm GI strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlappingand with 2 sets of brass nut bolt & spring washer spaced at 50mm) 407 Supply and Fixing of fire extinguisher of 5 Kg. capacity conforming to IS: 15683:2006 408 Rubber mats for electrical purpose as per IS:5425-1969, plain/chequered (1mX2m) - 19mm thickness 409 NOC from electrical safety department Govt. of UP 410 Fancing of substation in 2mtr height made from MS iron Jali & MS flat, angle iron andgrouting in propermannerincluding supply and laying of stone grit. 411 Internal&Externalelectrification 412 Twin tube light covered ĮED 20 Watt 413 450 mm dia exhaust fan 414 Providing & Fixing of IK07 IP-66 protected high power ĮED flood lightsystemwithPressurediecastaluminiumhousingĮM6/ ADC12 material 50 Watt Flood light 415 Complete wiring of HT and ĮT roomwith 1.5 Sqmm & 2.5 Sqmm multistarnd copper conductor wire 1.1 KV with required 5A & 15A switches, ceiling rose 416 S& F of all in one solar ĮED street light fixture with Integrated high efficient Monocrystalline panel with Įithium (ĮiFePO4) Ferro Phosphate battery with BIS approved make .luminaire should be secondaryopticlensesforbetterdistributionwithdelivered efficacy of >100 Įumen per watt. Įuminaire can be supplied with Hybridswitchalongwithindicatortounderstandthesource of power(eitherfromsolarorACsupply).shallhavecertificate testedfromMNREapprovedĮab.Guaranteefortotalsystemis two years .Note: All the above should be integrated and should be 1 system. make:Bajaj/ Philips / Crompton.Compact SolarLED StreetLight-60W/12V/27AhwithGIpole 417 Installation, testing and commissioning of 11 KV /.44 KV substations including H.T. panel and Į.T. panel including chequered plates, all labour T&P complete in all respect. 418 TestingofTransformer,HTandĮTPaneletcatManufacturer Works 419 11/0.44KVSUBSTATIONATCWRZONE-3 420 Supply of star rated Copper wound distribution Transformer ( All the distribution transformer must be star rated as per notification of(BEE)ministryofpower,GoverenmentofIndia)offollowing rating11/0.433KVDelta-StarConnected,VectorGroupDyn11, ONAN Cooled & as per BEE star level- 2 & BIS approved as per IS 2026-1977 & losses as defined as per IS 1180 part (I) 2014 including standardaccessorieslikeconservator,silicagel breather,Bucholzrelay,radiator,fins,HTcablebox&ĮTcable boxes, Off -ĮTC (+7.5% to - 15% @ 2.5%) temperature rise of 40 degree C in oil / 45 degree C in winding , ISI marked drain valve, DialtypeTemperaturegauge,OTI&WTI,marshallingbox,first filling of transformer oil as per IS :335-1953, Epoxy based paint.Ratingcapacity-160KVA(1w+1s) 421 Supplyof11KV,630 A,25kA/1Sec, VCBIndoortypepanelHT board, free standing motor operated & withdrawal type fabricated from 2 mm thick CRCA sheet steel , With Ammeter, Voltmeter, PF Meter, KWH Meter, MDI Meter, Selector Switches as required, CRT CT of required ratio (15VA ; Cl-1.0 / 0.5 ) PT (11 KV /110V/√3) , Fuses, IP42 Protection,4 / 8 /10 / 12-window Annunciation Panel , AC/ DC Control voltage 24/48/ 110/230V , ĮED Indication lamps , S/C, O/C&E/FProtection(IDMT)RelaysAlarm&tripcontactsfor Transformer protection(High oil temperature, Buchholz protection,highwindingtemperature,powerpack2x12V,etc completeinallrespectreadytouse(RTU),OEMMusthaveBIS certificate incuding 1no incoming & 2 no outgoing VCB 422 External batteryand batterycharger of suitablerating having 1 Hrs backup for H.T. Panel 423 Supply and laying of 11/12KV grade XĮPE H.T. cable as per IS:7098/ II/85,H4- Grade aluminium conductor of purity >99.6 % & as per IS:1554 P-I / IS :7098 P - (I)from UPPCĮmetering panel to H.T. Switch gear panel and panel to transformers 95Sq.mm.size 424 Supply of H.T. Cable end termination heat shrinkable type indoor joint kit 95sq.mm. 425 Supply of H.T. Cable end termination heat shrinkable type outdoor joint kit 95sq.mm. 426 Supply&layingofĮ.T.XĮPEinsulated armouredaluminium conductorcable of 1.1 KV grade Material :- H4- Grade aluminium conductorofpurity>99.6%&asperIS:1554P-I/IS:7098P- (I),conductorshallhaveelectrolyticaluminiumconfirmingtoIS 8130, IS 3975-1999.From transformer to Main ĮT panel of 3.5Cx 150Sq.mm. 427 Single front, Indoor & floor mounted,cubical type ĮT Panel factory fabricated (2 mm thick for sructure, 1.6mm thick for door,covers shroudsandGlandPlate-3mmthick)CRCAsheetdulypower coateddust andverminproofIP-54/IS:2147,consideredEarth Bus-Bar-GIStripcompitabletoSCADAoperationwithRS485 Port consisting ofINCOMMINGSECTION320A,50KA,TPN,MCCB microprocessorbaseed (O/C,S/C) release - 2 No , SpreaderĮinks & Extended ROH for - 2 No, 3 Phase Digital Multifunction Meter- 1 No, Digital Voltmeter 0-500V- 1 No, Digital Ammeter 0-400A- 1 Nos, CT For meter Resin Cast CĮ-1400A/5A,15VA - 3 Nos, Phase indication light ĮED type 220V AC - 1 Set, Control MCB SP 6A ,10KA ABB - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Įink - 1 No.OUTGOINGSECTION320A,50KA,TPN,MCCB microprocessorbased(O/C,S/C) REĮEASE - 1 No, spreader Įinks & Extended ROH for MCCB - 1 Nos., 63A TPN MCCB 32KA- 2 Nos. Terminal 63A 428 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick includingaccessories,andprovidingmasonryenclosurewith cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required according to latest IS:3043 429 Supplying and laying 50 mm X 6 mm GI strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlappingand with 2 sets of brass nut bolt & spring washer spaced at 50mm) 430 Supply and Fixing of fire extinguisher of 5 Kg. capacity conforming to IS: 15683:2006 431 Rubber mats for electrical purpose as per IS:5425-1969, plain/chequered (1mX2m) - 19mm thickness 432 NOC from electrical safety department Govt. of UP 433 Fancing of substation in 2mtr height made from MS iron Jali & MS flat, angle iron andgrouting in propermannerincluding supply and laying of stone grit. 434 Internal&Externalelectrification 435 Twin tube light covered ĮED 20 Watt 436 450 mm dia exhaust fan 437 Providing & Fixing of IK07 IP-66 protected high power ĮED flood lightsystemwithPressurediecastaluminiumhousingĮM6/ ADC12 material 50 Watt Flood light 438 Complete wiring of HT and ĮT roomwith 1.5 Sqmm & 2.5 Sqmm multistarnd copper conductor wire 1.1 KV with required 5A & 15A switches, ceiling rose 439 S& F of all in one solar ĮED street light fixture with Integrated high efficient Monocrystalline panel with Įithium (ĮiFePO4) Ferro Phosphate battery with BIS approved make .luminaire should be secondaryopticlensesforbetterdistributionwithdelivered efficacy of >100 Įumen per watt. Įuminaire can be supplied with Hybridswitchalongwithindicatortounderstandthesource of power(eitherfromsolarorACsupply).shallhavecertificate testedfromMNREapprovedĮab.Guaranteefortotalsystemis two years .Note: All the above should be integrated and should be 1 system. make:Bajaj/ Philips / Crompton.Compact SolarLED StreetLight-60W/12V/27AhwithGIpole 440 Installation, testing and commissioning of 11 KV /.44 KV substations including H.T. panel and Į.T. panel including chequered plates, all labour T&P complete in all respect. 441 TestingofTransformer,HTandĮTPaneletcatManufacturer Works 442 MASTERCONTROLSTATION(MCS) 443 CE/UĮ&BISCertifiedindustrialgradeĮEDMONITOR withlatest configuration as per specification 65 444 Video call media player of same OEM 445 Core i7 10th gen Desktop with 8 gb ram and 1 TB SSD 446 CE/UĮ Certified 3 KVA UPS with Batteries required for mentioned work wih 01 hrs backup 447 Full Development version of TAGS SCADA software with costomization ofsoftwareforMCSforunlimiteddigitalandanalogInput/output features as per requirements 448 CE/UĮ certified master control room PĮC with redundant CPU & power supply at MCS in IP-54 enclosure as per site requirement and specification required to complete in all respect 449 CE/UĮ certified Field gateway agent for transfering data for MCS/control room 450 GSM/GPRSbased wireless/Broadband/equivelent communication system for PĮC Capable to transfer and receive data & gather data from remotesitestocontrolstationsallaccessoriesincludedwithsignal enhancer, antenna along with running expences till 1 year 451 CE/UĮ certified Firewall for network protection 452 Surge protector for Ethernet communication protection 453 CE/UĮ Certified industrial grade Ethernet switch 454 Mobileappfacilitysystemarchitecture(industriesinternetbased& viewed through mobile apps for increasedblocal & remote visibility) 455 Canon/HP or equivalent Įaser Printer 1018 or equivalent. 456 Hp or equivalent multifunctioning Įaser Printer with scanner 457 BEE : 5 Star rating 1.5 Ton capacity air conditioner with voltage satbilizer 458 Office furniture ( office table - 2 No, revolving chair- 2No, Office chair-3 No, Godrej almirah - 1No) 459 Security Survelliance IP Camera with recorder 460 Supply and Fixing of fire extinguisher of 5 Kg. capacity conforming to IS: 15683:2006 461 Installation, Commissioning and testing of all above equipments for MCSwith all power cables 462 COST OF TRAIL & RUN FOR 3 MONTHS WITHOUT ELECTRICITY
Contract Date : 16 Jul, 2025   |   Contract Value : 34.98 Crore
BRR : 7607289 Tender for Rampura Nagar Panchayat Water Supply - Scheme Surveying, Soil Investigation, Design, Supply Of All Materials, Labour T P Etc. Required For Construction, Erection, Completion, Testing Commissioning Of Water Supply Works Such As Oht, Pump House, Staff Quarters Etc Complete - Construction of new R.C.C Over Head Tank (OHT) 2 Design & supply of all material T&P etc and construct RCC over head Tank of following capacity and staging with RCC staircase & 1m wide balcony, G.I pipes ralling consisting of 3 rows of 20mm dia G.I pipe and angle iron posts around balcony and at the dome periphery, M.S. ladder from balcony to top of tank and inside the tank, locking device, ventilator, lightening, conductor, fixing of puddle collars and bell mouths, supply and fixing M.S. clamps with RCC column, fixing of digital level indicator, 25mm PCC 1:2:4 over 80mm PCC 1:4:8 in apron, 15mm semicircular drain around the tank, escape channel of 20m length, of box type enclosure at the entrance of the staircase having locking arrangements, two coats of apex paint and testing of tank for water tightness etc. and also including the cost of supply and fixing of all necessary pipes and valves etc all complete. as per approved design and drawing 3 Zone -2800KL/18M 4 Renovation of R.C.C Over Head Tank (OHT) 5 Dismantiling of OHT DemagedFlooring Scrappingofold Surface OHT leakage RepairingPressure GroutingCement and water Proofing Coumpond Chemicalinternal wall and bottom dome to making of water tightness oftank body Repairing of Railing of Stair and Balcony with 20mm GI Pipe including changing of old pipe and refixing new pipe with angle ironpost Supply and Fixing of MS Stair Gate with box in 1/2 flight primar and painting complete cover and steel mosqueteo mesh in ventilatorlightening conductor making proper earthing Supply and Fixing ofDigital Water Level IndicatorScafoldingfor repairing & Painting of OHT Shuttering centringflooring Painting two coats of approved paint Apex Ultima orOHT including supply of all materials, labour and T&P etc required for Proper completion of the work in External of whole OHT with writing Of Scheme Details in tank Body 65x65x6 angle MS Lader inside and outerside of tank bodyWith railingPaintingof inlet, outlet, overflow and washoutpipe with black japan paint and flow mark with white paint.sluice valve and chamberwith all material etc complete.,all work instructed by engineer in charge 6 Zone -1500KL/17M 7 Rising Main 8 Supply ofDI K-7/K-9 Pipes of follwing sizes (Dia in mm) / Thickness as IS 8329/2000 or its latest amendment with jointing materials, specials of sizes required during construction included jointing material upto site of work included loading unloading cartage insurance, etc all completed but exclusive of GST in various zone as per the drawing and approval to Engineer. 9 DI K-9 150mm Dia 10 Supply of following size ofSluice Valves/ Scour Valves,capable for working pressure of 10 kg/cm2 Fire hydrants & Air Valves as per relevent I.S.I or its latest amandement. Up to store Including loading, unloading & cartage, taxes duties insurance etc all complete. As per IS: 2906-1969. 11 D.I. D/F Sluice valve/ Scour valve 150 mm Dia 12 Cartage of following size (dia in mm.) of DI K-7/K-9 pipesand specials includingjointingmaterials from store to site of worklowering the same into excavated pipe line tenches true toaligment and gradidient and jointing the same including testing of pipe line including supply of all materials labaour T&P etc complete and as per direction of engineer incharge 13 D.I. K-9/ 150 mm 14 Carting of following size of Sluice Valves/ Scour Valves,from store to site of work and lowering them into the trenches, fixing in position and jointing them with Pipe line and testing etc including supply of jointing materialand also including supply of all material and construction of suitable P.C.C Support below fittings etc. complete. 15 D.I. D/F Sluice valve/ Scour valve /D.I. K-9/ 150 mm 16 Dismantling of following types of roads including sorting out of servicable matarials stacking and disposal of unservicable matarials with in a distance of 50 m. including supply of labour specials T&P etc. required for proper completion of work 17 Interlocking tile 18 C C Road 19 Bitumenous Road 20 Reinstatement of following type of road surfaces after laying of pipe line including sorting out of serviceable materials and disposal of unserviceable material Compaction with mechanical Vibrators as per specifications and tender document including supply of all materials labour T&P etc complete and as per direction of engineer incharge. 21 Interlocking tile 22 C C Road 23 Bitumenous Road 24 Excavation for pipe line trenches in ordinary soil use ofspecialT&P etc. with lift upto 1.5 m lead upto 50 mincluding filling back of excavated earth into trenches and watering ranmming dressing and removal of surpluas earth upto 50.m including supply of all materials labour T&P etc complete and as per direction of engineer incharge. 25 R.C.C. Thrust block with cement, core sand, and 20mm gauges stone ballast in propotion of 1: 1.5:3 in thrust block of pipe line including reinforcementand its bending the same with 0.08 mm thick binding wire in position and necessary shuttring including proper curing and supply of all materials, labour and T&P etc required for proper completion of work. 26 Thrust Block 27 Provision for Nala/ Culvert crossing including all materials, labour and T&P etc. complete. It includes supply of D.I. pipe of necessary size for encasing, cement concrete and Brickwork for pillars and any other job for proper completion of work. 28 For crossing ofnalla/culvert/road upto 3.5 m wide(Trenchless) 29 For crossing ofnalla/culvert/road upto 7.0 m wide(Trenchless) 30 Constuction of following type of chamber as per type design & drawing & as per diretion of engineer incharge including all supply of materials etc. 31 Sluice valve/Scour Valve chamber (Masonary type ) 32 Distribution System 33 Supply ofHDPE Pipes grade PE 100/ PN 6 of follwing sizes (Dia in mm) / Thickness as IS 4984/2016 or its latest amendment with electrofusion jointing materials, specials and fittings of sizes required during construction included jointing material upto site of work included loading unloading cartage insurance, etc all completed but exclusive of GST in various zone as per the drawing and approval to Engineer. 34 HDPE PIPE GRADE PE 100/ PN 6- 90 mm 35 HDPE PIPE GRADE PE 100/ PN 6- 110 mm 36 HDPE PIPE GRADE PE 100/ PN 6- 125 mm 37 HDPE PIPE GRADE PE 100/ PN 6- 140 mm 38 HDPE PIPE GRADE PE 100/ PN 6- 160 mm 39 D.I. K-7/ 200 mm 40 D.I. K-7/ 250 mm 41 D.I. K-7/ 300mm 42 Supply of following size ofSluice Valves/ Scour Valves,capable for working pressure of 10 kg/cm2 Fire hydrants & Air Valves as per relerelavent I.S.I or its latest amandement. Up to store Including loading, unloading & cartage, taxes duties insurance etc all complete. As per IS: 2906-1969. 43 Air Valve as per as I.S : 14845 44 25 mm dia 45 D.I. D/F Sluice valve/ Scour valve 46 80 mm dia. 47 100 mm dia. 48 125 mm dia. 49 150 mm dia. 50 200 mm dia. 51 250 mm dia. 52 Fire hydrant (80 mm dia.) 53 Dismantling of following types of roads including sorting out of servicable matarials stacking and disposal of unservicable matarials with in a distance of 50 m. including supply of labour specials T&P etc. required for proper completion of work 54 Interlocking tile 55 C.C Road 56 Bituminous Road 57 B.O.E Road 58 Excavation for pipe line trenches in Ordinary soil requiring use ofspecialT&P etc. with lift upto 1.5 m lead upto 50 mincluding filling back of excavated earth into trenches and watering ranmming dressing and removal of surpluas earth upto 50.m including supply of alllabour T&P etc complete and as per direction of engineer incharge. 59 Cartage fromstore to site of work for following size (dia in mm)HDPE pipes and Specials coupling, fittings, and lowering the same into trenches and laying true to alignment and gradiant including testing of pipe lines cuttings of pipes for making up the length and making joints with electrofusion couplers, bands, tees, endcap etc. with electrofusion machinery including all jointing materials, labour, T&P etc required for proper completion of work. (excluding cost of trenching) 60 HDPE PIPE GRADE PE 100/ PN 6- 90 mm 61 HDPE PIPE GRADE PE 100/ PN 6- 110 mm 62 HDPE PIPE GRADE PE 100/ PN 6- 125 mm 63 HDPE PIPE GRADE PE 100/ PN 6- 140 mm 64 HDPE PIPE GRADE PE 100/ PN 6- 160 mm 65 Cartage of DI K-7 pipes and specials of following size (dia in mm)from store to site of work, lowering them into trenches and laying true to alignment and gradiant including testing of pipe line but excluding cost of trenching including all supply of Labour T&P etc complete required for proper completion of work. 66 D.I. K-7/ 200 mm 67 D.I. K-7/ 250 mm 68 D.I. K-7/ 300mm 69 Carting of following size of Sluice Valves/ Scour Valves, Fire hydrants & Air Valves from store to site of work and lowering them into the trenches, fixing in position and jointing them with Pipe line and testing etc including supply of jointing materialand also including supply of all material and construction of suitable P.C.C Support below fittings etc. complete. 70 20 mm. dia Air Valve 71 D.I. D/F Sluice valve/ Scour valve 72 80 mm dia. 73 100 mm dia. 74 125 mm dia. 75 150 mm dia. 76 200 mm dia. 77 250 mm dia. 78 Fire hydrant (80 mm dia.) 79 R.C.C. Thrust block with cement, core sand, and 20mm gauges stone ballast in propotion of 1: 1.5:3 in thrust block of pipe line including reinforcementand its bending the same with 0.08 mm thick binding wire in position and necessary shuttring including proper curing and supply of all materials, labour and T&P etc required for proper completion of work. 80 Thrust Block 81 Reinstatement of following type of road surfaces after laying of pipe line including sorting out of serviceable materials and disposal of unserviceable material Compaction with mechanical Vibrators as per specifications and tender document including supply of all materials labour T&P etc complete and as per direction of engineer incharge. 82 Interlocking tile 83 C.C Road 84 Bitumenous Road 85 B.O.E Road 86 Constuction of following type of chamber as per type design & drawing & as per diretion of engineer incharge including all supply of materials etc. 87 Sluice valve chamber 88 Scour Valve Chamber 89 Air Valve chamber 90 fire hydrant chamber 91 Provision for Nala/Culvert/road crossing including all materials, labour and T&P etc. complete. It includes supply of D.I. pipe of necessary size for encasing, cement concrete and Brickwork for pillars and any other job for proper completion of work. 92 For crossing ofnalla/culvert/road upto 3.5 m wide(Trenchless) 93 For crossing ofnalla/culvert/road upto 7.0 m wide(Trenchless) 94 TOAL 95 Sifting of HOUSE CONNECTION 96 Shifting of house connection from extsting distribution line to new pipe line in followingdia,withsupply of H.D.P.E. Average 6.00 mtr includingelectrofusion specials, Brass ferrule, Electrofusion Saddle clamp,tee bend ,union ,brass tap etc. of suitable size, resting on cc platform below ground level T&P etc. including excavation, laying and jointing for proper completion of work as per instructions of Engineer-in-charge includingthe cost of baling out and subsequent backfilland repair of subsequent leakages of joints, fittings and specials during work. 97 In C.C. Roads 98 For 90 mm to 110mm dia 99 For 125 mm to 160 mm dia 100 For 200 mm to 250 mm dia 101 For 250 mm to 300mm dia 102 In Bitumenous Roads 103 For 90 mm to 110mm dia 104 For 125 mm to 160 mm dia 105 For 200 mm to 250 mm dia 106 For 250 mm to 300mm dia 107 In B.O.E. Roads 108 For 90 mm to 110mm dia 109 For 125 mm to 160 mm dia 110 For 200 mm to 250 mm dia 111 For 250 mm to 300mm dia 112 In C.C. Interlocking Tiles Roads 113 For 90 mm to 110mm dia 114 For 125 mm to 160 mm dia 115 For 200 mm to 250 mm dia 116 For 250 mm to 300mm dia 117 In KacCha Roads 118 For 90 mm to 110mm dia 119 For 125 mm to 160 mm dia 120 For 200 mm to 250 mm dia 121 For 250 mm to 300mm dia 122 New House Connection 123 Making new House Connectionwith Distribution main of following dia and type of road including Dismantling and Reinstatement of road . Supply, cartingof elecrofusion specials as Saddel ,Tee ,Bend,brass ferrule, Union,H.D.P.E. pipe , HDPE adeptor ,GI pipe for drain crossing and avobe GL,loweringtheminto trenches , fixing them with CC block and clampincluding bailing out of water necessary excavation for connection with brass Tap including all labour , T&P etc. required for proper completion of the work. 124 In C.C. Roads 125 For 90 mm to 110mm dia 126 For 125 mm to 160 mm dia 127 For 200 mm to 250 mm dia 128 For 250 mm to 300mm dia 129 In Bitumenous Roads 130 For 90 mm to 110mm dia 131 For 125 mm to 160 mm dia 132 For 200 mm to 250 mm dia 133 For 250 mm to 300mm dia 134 In B.O.E. Roads 135 For 90 mm to 110mm dia 136 For 125 mm to 160 mm dia 137 For 200 mm to 250 mm dia 138 For 250 mm to 300mm dia 139 In C.C. Interlocking Tiles Roads 140 For 90 mm to 110mm dia 141 For 125 mm to 160 mm dia 142 For 200 mm to 250 mm dia 143 For 250 mm to 300mm dia 144 In Kacha Roads 145 For 90 mm to 110 mm dia 146 For 125 mm to 160 mm dia 147 For 200 mm to 250 mm dia 148 For 250 mm to 300mm dia 149 MISCELLANEOUS WORK 150 Construction of Pump House Cum Chloroneb (3.0 M X 2.5 M X 3.0 M , 1.8M X 1.2 M X 3.0 M, 1.5 WIDE VARANDAH)as per approved drawing and design based on RCCsingle reamed pile foundation , foundation beam, D.P.C. ,Ist class brick work ,M.S. Angle iron chaukhat of 50mm x 50mm x 6mm size for doors and windows, lintels, sun, shades slab etc,t concrete floor andapron on all sides ,by pass chamber ,Painting and varnishing of new iron work with one coat priming and two coat of approved apex paint and varnish ,Finishing walls with waterproof cement paint of approved make and quality yover one priming coat on new work with two coats to give an even shade, Supply of all material labour T&p complete as per instruction of engineer in charge. 151 Zone-1(1 nos) zone-2(2 nos.) 152 Repairing of Pump HouseAs required including Ist class brick work ,M.S. Angle iron chaukhat of 50mm x 50mm x 6mm size for doors and windows, lintels, sun, shades slab etc,t concrete floor andapron on all sides ,bypasschamber,Painting and varnishing of new iron work with one coat priming and two coat of approved apex paint and varnish,Finishing walls with waterproof cement paint of approved make and qualityover o ne priming coat on old work with two coats to give an even shade,Supply 153 Master control scada room(5.0x4.5x4.0m) zone-2as per approved drawing and design based on RCCsingle reamed pile foundation , foundation beam, D.P.C. ,Ist class brick work ,M.S. Angle iron chaukhat of 50mm x 50mm x 6mm size for doors and windows, lintels, sun, shades slab etc,t concrete floor andapron on all sides ,by pass chamber ,Painting and varnishing of new iron work with one coat priming and two coat of approved apex paint and varnish ,Finishing walls with waterproof cement paint of approved make and quality yover one priming coat on new work with two coats to give an even shade, Supply of all material labour T&p complete as per instruction of engineer in charge 154 Construction of RCC Pillar for rebore tubewell( zone 1) 155 Construnction of a half set of (area 45 sqm) one no. single Room staff quarters for Operator staff, pump operator , chaukidaar, pump attendent and other as per approved drawing and design based on RCCsingle reamed pile foundation , foundation beam, D.P.C. ,Ist class brick work ,M.S. Angle iron chaukhat of 50mm x 50mm x 6mm size for doors and windows, lintels, sun, shades slab etc,concrete floor andapron on all sides ,by pass chamber ,Painting and varnishing of new iron work with one coat priming and two coat of approved apex paint and varnish ,Finishing walls with waterproof cement paint of approved make and quality yover one priming coat on new work with two coats to give an even shade, Supply of all material labour T&p complete as per instruction of engineer in charge 156 zone 2 new construction staff quarter 157 Construction of 1.8m high boundary wall on pile foundation as per approved design and drawingand as per specification given in bid document inluding painting with 2 coats of all waether apex paint over one coat primer painting primer coat including supply of all material labour T&P etc for propercompletion of works as per instruction of engineer in charge.zone 2 new construction boundary 158 Water Campus Zone 1 repairing 159 zone 2 new construction boundary 160 Painting work in Boundary Wall zone-1 161 Supply and fixing 3.60 M & 1.20 M wide MS Gate with pillars including fabrication and supply of steel and construnction ofboundary pillars etc complete.zone-2 162 Provide all materials, labour, T&P etc Required for proper completion of work and construct Interlovking Tiles approach road, laid dry and joints intact with coarse sand mortar including preparation of base etc 163 Water Campus Zone 1 164 Water Campus Zone 2 165 Construnction of Drain in Water works Campus30 x 30 cm including labour material and t&p all complete 166 Zone-1 167 Zone-2 168 Filling of earth of lower portion including carting of earth upto 10 km including ramming , levelling and dressing at water works campus. 169 Zone-1 and zone-2 170 E/M Work 171 TUBEWELL CONSTRUTION (SIZE 300MM X 200MM) - 4 Nos. TW 172 Resistivity Survey of Tubewell Site 173 Transportation of rig machine erection, dismantling and associated T&P Complete in all respect including required all material , labour etc. 174 DRILLING OF TUBEWELL BORE 175 Drilling of 625 mm. dia bore from G.L. to 70 M. BGL (70x4) 176 Drilling of 500 mm. dia bore from 70 BGL to 100 M. BGL (30x4) 177 Drilling of 500 mm. dia bore from 100 BGL to 125 M. BGL (25x4) 178 Logging of bore hole by electirc logger 179 TUBEWELLASSEMBLY-MSERWTubewellassemblywithall required parts like plain pipe, slotted pipe, MS rings, well cap, bail plugclamp,reducer,centralguide,supportstructureetc.as required and as per typed design complete in all respect. 180 300 mm. dia 7.1 mm thick MSERW Plain Pipe with MS ring & reducer (62x4) 181 200 mm.dia 7.1 mm thick M.S. Plain pipe & Slotted pipe with MS ring (50x4) 182 LoweringofTubewellassemblydulyweldedincludingwelding electrode 183 300 mm. dia 7.1mm thick MSERW Plain / Slotted Pipe (62x4) 184 200 mm. dia Plain/Slotted Pipe 63 M. BGLto 100 M. BGL (38x4) 185 200 mm. dia Plain/Slotted Pipe 101 M. BGLto 112 M. BGL (12x4) 186 Supply & Shruoding of Lal Kuan Pea Gravel 1.6 to 4.8 mm. size for Tubewell (36x4) 187 DEVELOPMENT OF TUBEWELL 188 Transportation, Erection, Dismantling of 250 P.S.I. Compressor. 189 Charges for Development by 250 P.S.I. Compressor per hour.(60x4) 190 Transportation, Erection, Dismantling of 2 Cusec O.P. Unit and yeild Test. 191 Charges for Development by 2 Cusec O.P. Unitper hour. (80x4) 192 ChemicalandBacteriological testofwatersampleform departmentel / NABL approved lab. 193 CLEAR WATER SUBMERSIBLE PUMPING PLANT FOR TUBEWELLS TO OHT ZONE - 1 ( 600 KL EXSISTING ) 194 MECHANICAL & ELECTRICAL WORKS 195 Supply,installation,testingandcommissioningofClearwater submersiblepump(IS9236)completewithelectricmotor(IS8034) capable to operate on 380/420 volts 3 phase 50 c/s A.C. Capable for giving 800 LPM, 75 Mtr Head, 25 HP for New & Rebore Tube well 196 Supply,installation,testing andcommissioningof Main Piping & Valves with 24Mtr. Column pipe, power wiring, earthing, painting, wiring of pump house(Internal&External) completeinallrespectwithallrequired material, T&P labour 100 mm Dia. size 197 Supply of 3 Mtr Long Heavy duty exta Coloum pipe 100 mm Dia. Size (6 No for each TW ) 198 Supply of Motor operated actuators forsluice valve suitable for SCADA operationwithlimitswitches,autodeclutchformanualoperationin emergencyetcasperrelevantISsuitablefor100mmdiasizesluice valve 199 Supply of D.I./ D.F. Dismantling Joints is a variable length Double Flanged ShortPiececonstitutedbya flange/ SpigotTailpieceinsertedintothe other Tailpiece which allows the distance between the two flanges to be variedwithincertainlimitsthusprovidingavariabledistancepiece betweentwofixedflangeenddeviceslikePumpsandValves.The Dismantling Joint to be supplied complete with Sealing Rubber Gaskets of EPDM quality (IS:5382/1985 Type-4), Cast Iron Follower Glands and Mild Steel (Zinc Coated) Nut Bolts of 100 mm dia size 200 ExtraSubmersibleflatcoppercondutorcable3Cx6sq.mmPVC Sheathed double run (2Rx25m = 50 mtr for each TW) 201 Supply& laying of L.T. XLPE insulatedarmouredaluminiumconductor cable of 1.1 KV grade Material :- H4- Grade aluminium conductor of purity>99.6%&asperIS:1554P-I/IS:7098P-(I),conductorshallhave electrolytic aluminium confirming to IS 8130, IS 3975-1999.From transformer to Main LT panel of 3.5C x 35 Sq.mm. 202 Pumping Plant Motor inspection, B&L and Challan fee 203 MOTOR CONTROL CENTER (MCC) PANEL :-Single front, Indoor & floor mounted,cubical type Panel factory fabricated (2 mm thick for sructure, 1.6mm thick for door,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coateddust and vermin proof IP-54 / IS:2147, considered Earth Bus-Bar-GI Strip compitable to SCADA operation with RS485 Port consisting of63 A, 50KA, TPN, MCCB microprocessor baseed(O/C,S/C) release - 1 No , Spreader Links & Extended ROH for - 1 No, 3 Phase Digital Multifunction Meter- 1 No, Digital Voltmeter 0-500V- 1 No, Digital Ammeter 0-400A-1Nos,CTFormeterResinCastCL-1400A/5A,15VA-3Nos,Phase indication light LED type 220V AC - 1 Set, Control MCB SP 6A ,10KA - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Link - 1 No. 204 Supply of Air Cooled Digital soft starter suitable for the LT motor offered for operation in AC three Phase 50Hz (+/- 5%), 415V(+/-10%) including line contactors suitable for next standard higher KW rating, Over & Under load protection, short circuit & single phasing protection with frequency meter, Ammeter,Voltmeter,indicatinglamp6Nos, LED ON/OFF type and Start/StoppushbuttonandInstrumentFuses,suitabletoSCADAoperation with RS485 Port of rating capacity 25 HP / 18.50 KW 205 Supplyofmicroprocessorbasedthreephasesensingpowerfactor correctionrelaypanel,IEC/EN61000-6-(2&4)having3CTsensing, sensitivity up to 50 milli amp secondary current , self analysing auto c/k setting according to targeted powerfactor setting, the relay shall have digit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current, insufficient compensation, communication interface with RS 485, indication of switching on units, auto/manual status, and shall have over load protection, no volt release , having multiparameterlike KW, KVA, KVAR rating capacity of 20 KVAR 206 Supply of Servo Controlled Automatic Voltage stabilizer suitable for out put voltage of 415 Volt +/-1%, 3 Ph, 50 Hz, with copper wound transformer (air/oilcooled).Thestabilizer shall functionsatisfactorily evenif incoming supply is unbalanced between phases within range of 10%. The stabilizer should be constructed in cubical box, with bi-directional wheels for easy handling, necessary monitors and users controls on front panel such as indication, alarm, volt meter and selector switch for measuring input and out put voltage, Auto/Manual selector switch, Raise/Low push buttonsetc.Suitable capacity termination stripsandbusbars for incoming and out going cable should be provided. All three phases shall beindependentlymonitoredandcorrected(Operatingvoltage240V- 500V), 415 volt, 3Phase, 50Hz of40 KVAcapacity 207 Supply of Change over or by pass switch rating capacity 63 Amp 208 Supply of 2 Ton 4.5 mtr lift chain pully block 209 SupplyofAutophasereversalunit with inbuilttimedelay& enclosure (conforming to IEC:60947-1 & IEC:60947-b-1) 63 Amp rating 210 Supply of CE/UL Certified Surge protector for control panel 211 Providing & Fixing of IK07 IP-66 protected high power LED flood light system with Pressure diecast aluminium housing LM6/ ADC12 material 50 Watt Flood light 212 SupplyofAutomatic/SCADAoperatedelectromegnaticchlorination dozzer system 213 INSTRUMENTATION WORK 214 Supply of CE/UL Certified pressure transmitter CE markd with following technical parametersand Interfacing with PLC panel including mounting arrangement.Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 215 SupplyofCE/ULCertifiedFullBoreElectromagneticFlowMeterof approved make of following dia and specifications complete: Media: Water (Raw/Chlorinated) , Pressure :up to 1.0MPa, Process temp:-50degC, Flow/MeterTube:SS304, Electrode:SSAISI 316L /Hastelloy C276/Tantalum,LiningMaterial:HardRubber/ Neoprene/Poly-urethane(PU) , Flange : SS /CS, Flange Standard & Rating:ANSI150,Coilhousing:SSAISI304/CarbonSteel/DieCast Aluminium,with anticorrosive paint & provide completelysealed(leak proof)constructionasperrequirement‘ofIEC 60529, Accuracy : + 0.5% M.V.- velocity 0.3 to 10 m/s, Transmitter/ signa convertorEnclosure: Die CastAluminium,Power Supply : 80-240V AC - 5OHz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart,Display Type: LCD/ LED Display,Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable, of100 mm dia size at delivery header 216 CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with intelligent GSM Based modem unit with CPU and Power Supply with analogandDigitalParameterandfeaturesasspecified tostoreand transmit data on GSM backbone, RTU designed with logic to tansfer data atmultiplestationsandalsocompatibleforsatellitecommunication alongwithcontrolpanelwithIP54Protection,Industrialgradeforall equipment and 24V and power supply for Tubewell 217 GSM/GPRS based wireless communication with 4G modem for RTU/PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer, antenna made for pumping plantwith SIM andrecharge for Tubewell 218 CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with intelligent GSM Based modem unit with CPU and Power Supply with analogandDigitalParameterandfeaturesasspecified tostoreand transmit data on GSM backbone, RTU designed with logic to tansfer data atmultiplestationsandalsocompatibleforsatellitecommunication alongwithcontrolpanelwithIP54Protection,Industrialgradeforall equipment and 24V and power supply for OHT due to out side Tubewell campus 219 GSM/GPRS based wireless communication with 4G modem for RTU/PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer, antenna made for pumping plantwith SIM andrecharge for OHT due to out side Tubewell campus 220 Supply of CE/UL cirtified of Radar type level transmitter CE marked with following technical parameters and Interfacing with PLC panel including mounting arrangement for OHTOutput-4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 221 CE&ULCertified7 HMItouchscreensuitabletocommunicationwith PLC/RTU for local display & control of process parameters 222 CE/UL Certified Intelligent energy meters 223 SupplyofElectricallyMotoroperatedactuatorwithbracketfor sluice valve suitable for SCADA operation with limit switches, auto de clutch for manual operation in emergency etcas per relevant IS suitable for 300 mm dia size sluice valveat OHT outlet 224 Completecablingforinstrumentation/SCADAequipmentswithpower supply of panels form source for Tubewell & OHT 225 Security Survelliance IP Camera with all required accessories 226 Supply and Fixing of fire extinguisher of 5 Kg. capacity conforming to IS: 15683:2006 227 Rubber mats for electrical purpose as per IS:5425-1969, plain/chequered (1mX2m) - 19mm thickness 228 Tool set:-Spenners -2Nos, AdjustableWrinchset-2Nos,sizewrinchesof different sizes - 1 Set, Gigital Tong tester - 1 Nos, Digital Clamp meter - 1 No, megger 5Mva- 1 No, Hydraulic crimping tool 500 Sq mm size - 1 No, Sand PPM measuring kit - 1 No, Digital Screw Gauge 40mm size - 1 No, Inner & Outer pipe gauge set 500mm size - 1 Set, Filler gauges - 1 Set, Electronic battery operated water level / depth gauge with meter marking upto 400 mtr depth - 1 No 229 Installation,testing and comissioning of pumpingplant & associated all equipmentsas per approveddrawing shall be done by bidder including painting of pumping plant & main piping-valves. 230 Testing of Pumping Plant & Control Panel & valves etc at Manufacturer Works 231 CLEAR WATER SUBMERSIBLE PUMPING PLANT FOR TUBEWELLS TO OHT ZONE - 2 ( 800 KL NEW ) 232 Supply,installation,testingandcommissioningofClearwater submersiblepump(IS9236)completewithelectricmotor(IS8034) capable to operate on 380/420 volts 3 phase 50 c/s A.C. Capable for giving 800 LPM, 75 Mtr Head, 25 HP for New Tube well 233 Supply,installation,testingandcommissioningofClearwater submersiblepump(IS9236)completewithelectricmotor(IS8034) capable to operate on 380/420 volts 3 phase 50 c/s A.C. Capable for giving 600 LPM, 75 Mtr Head, 20 HP for Exsisting Tube well 234 Supply,installation,testing andcommissioningof Main Piping & Valves with 24Mtr. Column pipe, power wiring, earthing, painting, wiring of pump house(Internal&External) completeinallrespectwithallrequired material, T&P labour 100 mm Dia. size 235 Supply,installation,testing andcommissioningof Main Piping & Valves with 24Mtr. Column pipe, power wiring, earthing, painting, wiring of pump house(Internal&External) completeinallrespectwithallrequired material, T&P labour 80 mm Dia. size 236 Supply of 3 Mtr Long Heavy duty exta Coloum pipe 100 mm Dia. Size (6 No for each TW ) 237 Supply of 3 Mtr Long Heavy duty exta Coloum pipe 80 mm Dia. Size (6 No for each TW ) 238 Supply of Motor operated actuators forsluice valve suitable for SCADA operationwithlimitswitches,autodeclutchformanualoperationin emergencyetcasperrelevantISsuitablefor100mmdiasizesluice valve 239 Supply of Motor operated actuators forsluice valve suitable for SCADA operationwithlimitswitches,autodeclutchformanualoperationin emergency etcas per relevant IS suitable for 80 mm dia size sluice valve 240 Supply of D.I./ D.F. Dismantling Joints is a variable length Double Flanged ShortPiececonstitutedbya flange/ SpigotTailpieceinsertedintothe other Tailpiece which allows the distance between the two flanges to be variedwithincertainlimitsthusprovidingavariabledistancepiece betweentwofixedflangeenddeviceslikePumpsandValves.The Dismantling Joint to be supplied complete with Sealing Rubber Gaskets of EPDM quality (IS:5382/1985 Type-4), Cast Iron Follower Glands and Mild Steel (Zinc Coated) Nut Bolts of 100 mm dia size 241 Supply of D.I./ D.F. Dismantling Joints is a variable length Double Flanged ShortPiececonstitutedbya flange/ SpigotTailpieceinsertedintothe other Tailpiece which allows the distance between the two flanges to be variedwithincertainlimitsthusprovidingavariabledistancepiece betweentwofixedflangeenddeviceslikePumpsandValves.The Dismantling Joint to be supplied complete with Sealing Rubber Gaskets of EPDM quality (IS:5382/1985 Type-4), Cast Iron Follower Glands and Mild Steel (Zinc Coated) Nut Bolts of 80 mm dia size 242 ExtraSubmersibleflatcoppercondutorcable3Cx6sq.mmPVC Sheathed double run (2Rx25m = 50 mtr for each TW) 243 Supply& laying of L.T. XLPE insulatedarmouredaluminiumconductor cable of 1.1 KV grade Material :- H4- Grade aluminium conductor of purity>99.6%&asperIS:1554P-I/IS:7098P-(I),conductorshallhave electrolytic aluminium confirming to IS 8130, IS 3975-1999.From transformer to Main LT panel of 3.5C x 35 Sq.mm. 244 Pumping Plant Motor inspection, B&L and Challan fee 245 MOTOR CONTROL CENTER (MCC) PANEL :-Single front, Indoor & floor mounted,cubical type Panel factory fabricated (2 mm thick for sructure, 1.6mm thick for door,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coateddust and vermin proof IP-54 / IS:2147, considered Earth Bus-Bar-GI Strip compitable to SCADA operation with RS485 Port consisting of63 A, 50KA, TPN, MCCB microprocessor baseed(O/C,S/C) release - 1 No , Spreader Links & Extended ROH for - 1 No, 3 Phase Digital Multifunction Meter- 1 No, Digital Voltmeter 0-500V- 1 No, Digital Ammeter 0-400A-1Nos,CTFormeterResinCastCL-1400A/5A,15VA-3Nos,Phase indication light LED type 220V AC - 1 Set, Control MCB SP 6A ,10KA - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Link - 1 No. 246 Supply of Air Cooled Digital soft starter suitable for the LT motor offered for operation in AC three Phase 50Hz (+/- 5%), 415V(+/-10%) including line contactors suitable for next standard higher KW rating, Over & Under load protection, short circuit & single phasing protection with frequency meter, Ammeter,Voltmeter,indicatinglamp6Nos, LED ON/OFF type and Start/StoppushbuttonandInstrumentFuses,suitabletoSCADAoperation with RS485 Port of rating capacity 25 HP / 18.50 KW 247 Supplyofmicroprocessorbasedthreephasesensingpowerfactor correctionrelaypanel,IEC/EN61000-6-(2&4)having3CTsensing, sensitivity up to 50 milli amp secondary current , self analysing auto c/k setting according to targeted powerfactor setting, the relay shall have digit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current, insufficient compensation, communication interface with RS 485, indication of switching on units, auto/manual status, and shall have over load protection, no volt release , having multiparameterlike KW, KVA, KVAR rating capacity of 20 KVAR 248 Supply of Servo Controlled Automatic Voltage stabilizer suitable for out put voltage of 415 Volt +/-1%, 3 Ph, 50 Hz, with copper wound transformer (air/oilcooled).Thestabilizer shall functionsatisfactorily evenif incoming supply is unbalanced between phases within range of 10%. The stabilizer should be constructed in cubical box, with bi-directional wheels for easy handling, necessary monitors and users controls on front panel such as indication, alarm, volt meter and selector switch for measuring input and out put voltage, Auto/Manual selector switch, Raise/Low push buttonsetc.Suitable capacity termination stripsandbusbars for incoming and out going cable should be provided. All three phases shall beindependentlymonitoredandcorrected(Operatingvoltage240V- 500V), 415 volt, 3Phase, 50Hz of following capacity 249 Servo Controlled Automatic Voltage stabilizer of 40 KVA 250 Servo Controlled Automatic Voltage stabilizer of 30 KVA 251 Supply of Change over or by pass switch rating capacity 63 Amp 252 Supply of 2 Ton 4.5 mtr lift chain pully block 253 SupplyofAutophasereversalunit with inbuilttimedelay& enclosure (conforming to IEC:60947-1 & IEC:60947-b-1) 63 Amp rating 254 Supply of CE/UL Certified Surge protector for control panel 255 Providing & Fixing of IK07 IP-66 protected high power LED flood light system with Pressure diecast aluminium housing LM6/ ADC12 material 50 Watt Flood light 256 SupplyofAutomatic/SCADAoperatedelectromegnaticchlorination dozzer system 257 INSTRUMENTATION WORK 258 Supply of CE/UL Certified pressure transmitter CE markd with following technical parametersand Interfacing with PLC panel including mounting arrangement.Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 259 SupplyofCE/ULCertifiedFullBoreElectromagneticFlowMeterof approved make of following dia and specifications complete: Media: Water (Raw/Chlorinated) , Pressure :up to 1.0MPa, Process temp:-50degC, Flow/MeterTube:SS304, Electrode:SSAISI 316L /Hastelloy C276/Tantalum,LiningMaterial:HardRubber/ Neoprene/Poly-urethane(PU) , Flange : SS /CS, Flange Standard & Rating:ANSI150,Coilhousing:SSAISI304/CarbonSteel/DieCast Aluminium,with anticorrosive paint & provide completelysealed(leak proof)constructionasperrequirement‘ofIEC 60529, Accuracy : + 0.5% M.V.- velocity 0.3 to 10 m/s, Transmitter/ signa convertorEnclosure: Die CastAluminium,Power Supply : 80-240V AC - 5OHz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart,Display Type: LCD/ LED Display,Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/convertor, including Surge Arrester, cable,of following size. 260 Flow meter of 100 mm dia size at outlet 261 Flow meter of 80 mm dia size at outlet 262 CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with intelligent GSM Based modem unit with CPU and Power Supply with analogandDigitalParameterandfeaturesasspecified tostoreand transmit data on GSM backbone, RTU designed with logic to tansfer data atmultiplestationsandalsocompatibleforsatellitecommunication alongwithcontrolpanelwithIP54Protection,Industrialgradeforall equipment and 24V and power supply for Tubewell & OHT 263 GSM/GPRS based wireless communication with 4G modem for RTU/PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer, antenna made for pumping plantwith SIM andrecharge 264 Supply of CE/UL cirtified of Radar type level transmitter CE marked with following technical parameters and Interfacing with PLC panel including mounting arrangementfor OHTOutput-4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 265 CE&ULCertified7 HMItouchscreensuitabletocommunicationwith PLC/RTU for local display & control of process parameters 266 CE/UL Certified Intelligent energy meters 267 SupplyofElectricallyMotoroperatedactuatorwithbracketfor sluice valve suitable for SCADA operation with limit switches, auto de clutch for manual operation in emergency etcas per relevant IS suitable for 300 mm dia size sluice valveat OHT outlet 268 Completecablingforinstrumentation/SCADAequipmentswithpower supply of panels form source for Tubewell & OHT 269 Security Survelliance IP Camera with all required accessories 270 Supply and Fixing of fire extinguisher of 5 Kg. capacity conforming to IS: 15683:2006 271 Rubber mats for electrical purpose as per IS:5425-1969, plain/chequered (1mX2m) - 19mm thickness 272 Installation,testing and comissioning of pumpingplant & associated all equipmentsas per approveddrawing shall be done by bidder including painting of pumping plant & main piping-valves. 273 Testing of Pumping Plant & Control Panel & valves etc at Manufacturer Works 274 MASTER CONTROL STATION (MCS) 275 CE/UL&BISCertifiedindustrialgradeLEDMONITOR withlatest configuration as per specification 65 276 Video call media player of same OEM 277 Core i7 10th gen Desktop with 8 gb ram and 1 TB SSD 278 CE/UL Certified 3 KVA UPS with Batteries required for mentioned work wih 01 hrs backup 279 Full Development version of TAGS SCADA software with costomization ofsoftwareforMCSforunlimiteddigitalandanalogInput/output features as per requirements 280 CE/UL certified master control room PLC with redundant CPU & power supply at MCS in IP-54 enclosure as per site requirement and specification required to complete in all respect 281 CE/UL certified Field gateway agent for transfering data for MCS/control room 282 GSM/GPRSbased wireless/Broadband/equivelent communication system for PLC Capable to transfer and receive data & gather data from remotesitestocontrolstationsallaccessoriesincludedwithsignal enhancer, antenna along with running expences till 1 year 283 CE/UL certified Firewall for network protection 284 Surge protector for Ethernet communication protection 285 CE/UL Certified industrial grade Ethernet switch 286 Mobileappfacilitysystemarchitecture(industriesinternetbased& viewed through mobile apps for increasedblocal & remote visibility) 287 Canon/HP or equivalent Laser Printer 1018 or equivalent. 288 Hp or equivalent multifunctioning Laser Printer with scanner 289 BEE : 5 Star rating 1.5 Ton capacity air conditioner with voltage satbilizer 290 Office furniture ( office table - 2 No, revolving chair- 2No, Office chair-3 No, Godrej almirah - 1No) 291 Security Survelliance IP Camera with recorder 292 Supply and Fixing of fire extinguisher of 5 Kg. capacity conforming to IS: 15683:2006 293 Installation, Commissioning and testing of all above equipments for MCSwith all power cables 294 TRAIL & RUN FOR 3 MONTHS WITHOUT ELECTRICITY
Contract Date : 16 Jul, 2025   |   Contract Value : 12 Crore
Disclaimer

We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.

Tender Detail
Website https://etender.cpwd.gov.in/login.html
Quantity
MSME Exemption No
Tender Type Open Tender
Startup Exemption Click Here
Competitive Bidding NCB
Similar Tenders
TENDER INSIGHTS

858

Electric Tenders
Live
CLICK TO KNOW MAXIMUM WIN

Tell us about your Product / Services,

We will Find Tenders for you

🇮🇳 +91
TenderDetail
Loading tenders