TDR : 57157601
Central Public Works Department

Tender Brief :

Manesar, Haryana

Up Gradation Of Officers Messes Of Various Units At NSG Manesar Gurugram SH Renovation And Upgradation Of Officers Mess Of Training Centre 11 SRG And 51 SAG At NSG Manesar Camp Manesar Gurgaon Civil And Electrical Works

Published: 22 Aug 2026
Opening: 05 Sep 2026
Closing: 05 Sep 2026
Amount: 8.07 Crore
EMD: 16.14 Lakhs
Tender Fee: Ref. Documents


Works Acid Storage Tank Active Harmonic Filter Actuator Aerial Cable Aerobridge
9
Days Left
Tender Summary / Eligibility Criteria
Up Gradation Of Officers Messes Of Various Units At NSG Manesar Gurugram SH Renovation And Upgradation Of Officers Mess Of Training Centre 11 SRG And 51 SAG At NSG Manesar Camp Manesar Gurgaon Civil And Electrical Works
Documents Download All
23be22ff-77a4-4d54-9065-29140c7de18f
23be22ff-77a4-4d54-9065-29140c7de18f.html
DocumentsList
DocumentsList.zip
No Boq
No Corrigendum
Probable Bidders

AI engine predicts probable bidders to help you bid strategically.

MSME Exception
Explore More →
Technical
Tender involves procurement of high capacity electrical equipment including diaphragm coupling of pump & motor with 90kW capacity at 2900 RPM. The project scope includes installation, testing, commissioning and operational handover.
Previous / Similar Result
BRR : 7682544 Renovation Works At District Tb Centre Wayanad District, Kerala - 1 CIVIL WORKS 2 DISMANTILING AND DEMOLISHING 3 Demolishing brick work manually / by mechanical means including stacking ofserviceable material and disposal of unserviceable material within 50 metres lead asper direction of Engineer-in-Charge. In cement mortar 4 Dismantling steel work in built up sections in angles, tees, flats and channelsincluding all gusset plates,boltd, nuts, cutting rivets, welding etc. includingdismembering and stacking within 50 metres lead. 5 Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking thematerial within 50 metres lead of :G.S. Sheet 6 Dismantling aluminium / Gypsum partitions, doors, windows, fixed glazing and falseceiling including disposal of unserviceable surplus material and stacking ofserviceable material with in 50 metres lead as directed by Engineer - in-Charge 7 Demolishing R.C.C. work manually / by mechanical means including stacking ofsteel bars and disposal of unserviceable material with in 50 metres lead as perdirection of Engineer -in-Charge. 8 Dismantling of plumbing pipe lines of 15mm dia to 110mm dia pipes, includingstacking of useful materials near the site and disposal of unserviceable materialswithin 50 metres lead as per the direction of engineer in-charge. 9 EARTHWORK EXCAVATION 10 Earth work in excavation by mechanical means (Hydraulic excavator) /manual meansin foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift up to 1.5 m, includinggetting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.All kinds of soil 11 PCC 12 Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering -All work upto plinth level1:4:8 (1 cement : 4 coarsesand : 8 graded stone aggregate 40 nominal size) 13 Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering -All work above plinth level up to floor fivelevel1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 14 RCC 15 Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete above plinth level.Thermo - MechanicallyTreated bars of grade Fe-500D or more 16 Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete upto plinth levelThermo - Mechanically Treatedbars of grade Fe-500D or more 17 Providing and laying in position machine batched and machine mixed design mix M 25 grade cement concrete for reinforced cement concrete work, using cement contentas per approved design mix, including pumping of concrete to siteof laying butexcluding the cost of centering, shuttering, finishing and reinforcement, includingadmixtures in recommended proportions as per IS: 9103 to accelerate, retard settingof concrete, improve workability without impairing strength and durability as perdirection of Engineer - in-charge. .All work above plinth level upto floor V level 18 Providing and laying in position machine batched and machine mixed design mix M 25 grade cement concrete for reinforced cement concrete work, using cement contentas per approved design mix, including pumping of concrete to siteof laying butexcluding the cost of centering, shuttering, finishing and reinforcement, includingadmixtures in recommended proportions as per IS: 9103 to accelerate, retard settingof concrete, improve workability without impairing strength and durability as perdirection of Engineer - in-charge.All work upto plinth level. 19 Providing and supplying of Decking Sheet plates ofwidth 0.94m, thickness 1mm , crest height 51mm and width(top) 91mm, width (bottom) 143mm. The rate inclusive of material, transportation, scaffolding . as per the direction of Engineer in charge. ( The steel frame work should be paid seperately ) 20 FORM WORK 21 Centering and shuttering including strutting, etc. and removal of form for:Suspendedfloors, roofs, landings, balconies and access platform 22 Centering and shuttering including strutting, etc. and removal of form for:Lintels,beams, plinth beams, girders bressumers and cantilevers 23 Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide 24 Centering and shuttering including strutting, etc. and removal of form for:Columns,Pillars, Piers, Abutments, Posts and Struts 25 Centering and shuttering including strutting, etc. and removal of form for:Weathershade, Chajjas, corbels etc., including edges 26 MASONRY WORKS 27 Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearestsize in cement mortar 1:6 for super structure above plinth level up to floor two levelincluding all cost of materials, labour charges etc. 28 STONE WORK 29 Random rubble masonry with hard stone in foundation and plinth including levellingup with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarsesand) 30 PLASTERING 31 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 32 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand) 33 DOORS AND WINDOWS 34 Providing and fixing to existing door frames24 mm thick factory made PVC doorshutters made of styles and rails of a uPVC hollow section of size 59x24 mm and wallthickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The styles and railsmitred and joint at the corners by means of M.S. galvanised/plastic brackets of size75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles ofthe shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm(± 0.1 mm) wall thickness. The lock rail made up of H section, a uPVC hollowsection of size 100x24 mm and 2 mm (± 0.2 mm) wall thickness,fixed to the shutterstyles by means of plastic/galvanised M.S. U cleats. The shutter frame filled with auPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled verticallyand tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod andfastened with nuts and washers, complete as per manufacturers specification anddirection of Engineer-in-charge( For W.C. and bathroom door shutter). 35 Providing and fixing factory made uPVC door frame made of uPVC extrudedsections having an overall dimension as below (tolerance ±1 mm), with wall thickness2.0mm (±0.2 mm), corners of the door frame to be jointed with galvanized bracketsand stainless steel screws, joints mitred and plastic welded. The hinge side vertical ofthe frames reinforced by galvanized M.S. tube of size19 x 19 mm and 1 mm (± 0.1mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete asper manufacturers specification and direction of Engineer-in-chargeExtruded sectionprofile size 48x40 mm 36 Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating notless than grade AC 10 as per : 1868), transparent or dyed to required colour or shade,with necessary screws complete:100x10 mm 37 Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mmnominal size) 38 Extra for providing ISI marked Stainless Steel butt hinges instead of M.S. pressedbutt hinges bright finished of required size with necessary screws. ( Shutter area to bemeasured) 39 Providing and fixing bright finished 100 mm mortice lock with 6 levers without pairof handles of approved quality for aluminium door, with necessary screws etccomplete as per direction of Engineer- in- charge. 40 Providing and fixing 12 mm thick frameless toughened glass door shutter of approvedbrand and manufacture, including providing and fixing top & bottom pivot & springtype fixing arrangement and making necessary holes etc. for fixing required doorfittings, all complete as per direction of Engineer-in-charge ( Door handle, lock andstopper etc to be paid separately) 41 Providing and fixing of glass door SS Patch Lock with out handle in toughened glassdoor including all necessary screws etc. complete. . 42 Providing and fixing Steel S.S- 304 (D) DoorHandle of 450mm(1 Handles) ( bestmake of approved quality ) for Glass, Wooden or similar doors including necessarycutting and making good etc. complete 43 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I)decorative type, core of block board construction with frame of I st class hard woodand well matched teak 3 ply veneering with vertical grains or cross bands and faceveneers on both faces of shutters.35 mm thick including ISI marked Stainless Steelbutt hinges with necessary screws 44 Providing wood work in frames of doors, windows, clerestory windows and otherframes, wrought framed and fixed in position with hold fast lugs or with dashfasteners of required dia & length (hold fast lugs or dash fastener shall be paid forseparately), using good quality Anjili wood /jack wood 45 TILE WORKS 46 Extra for providing opening or required size & shape for wash basin/kitchen sink inkitchen platform, vanity counter and similar location in marble/granite/ stone work,including necessary holes for pillar taps etc. including moulding, rubbing andpolishing of cut edges etc. complete. 47 Providing and laying vitrified floor tiles in different sizes (thickness to be specified bythe manufacturer) with water absorption less than 0.08% and conforming to IS :15622, of approved make, in all colours and shades, laid on 20 mm thick cementmortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cementand matching pigments etc., complete.Size of Tile 600 x 600 mm. 48 Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622(thickness to be specified by the manufacturer), of approved make, in all colours,shades except burgundy, bottle green, black of any size as approved by Engineer -in Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm,including pointing in white cement mixed with pigment of matching shade complete. 49 Providing and laying Vitrified tiles indifferent sizes (thickness to be specified bymanufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622,ofapproved make, in all colours & shade, in skirting, riser of steps, over 12 mm thickbed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint withwhite cement & matching pigments etc. complete.Size of Tile 600x600 mm 50 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to bespecified by the manufacturer), of 1st quality conforming to IS : 15622, of approvedmake, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thickcement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints withwhite cement and matching pigment etc., complete. 51 Taking out existing CC interlocking paver blocks from footpath/ central verge,including removal of rubbish etc., disposal of unserviceable material to the dumpingground, for which payment shall be made separately and stacking of serviceablematerial within 50 metre lead as per direction of Engineer-in-Charge. 52 Laying old cement concrete interlocking paver blocks of any design/ shape laid inrequired line, level, curvature, colour and pattern over and including 50 mm thickcompacted bed of coarse sand, filling the joints with fine sand etc. all complete as perthe direction of Engineer-in-charge. (Old CC paver blocks shall be supplied by thedepartment free of cost.) 53 Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded andprepolished, machine cut for kitchen platforms, vanity counters, window sills, faciasand similar locations, of required size, approved shade, colour and texture laid over20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated withwhite cement, mixed with matching pigment, epoxy touch ups, including rubbing,curing, moulding and polishing to edges to give high gloss finish etc. complete at alllevels. Granite stone slab of colour black , cherry / ruby red .Area of slab over 0.50sqm 54 Providing and laying 60 mm thick factory made cement concrete interlocking paverblock of M - 30 grade made by block making machine with strong vibratorycompaction, of approved size, design & shape, laid in required colour andpattern over and including 50 mm thick compacted bed of coarse sand, filling thejoints with fine sand etc. all complete as per the direction of Engineer-in-charge. 55 ALUMINIUM WORKS 56 Providing and fixing aluminium work for doors, windows, ventilators and partitionswith extruded built up standard tubular sections/ appropriate Z sections and othersections of approved make conforming to IS : 733 and IS: 1285, fixing with dashfasteners of required dia and size, including necessary filling up the gaps at junctions,i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc.Aluminium sections shall be smooth, rust free, straight, mitred and jointedmechanically wherever required including cleat angle, Aluminnium snap beading forglazing /paneling, C.P. brass/ stainless steel screws, all complete as per architecturaldrawings and the directions of Engineer-in-charge.(Glazing, paneling and dashfasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) 57 For shutters of doors, windows & ventilators including providing and fixing hinges /pivots and making provision for fixing of fittings wherever required including thecost of EPDM rubber/ neoprene gasket required (Fittings shall be paid forseparately)Powder coated aluminium (minimum thickness of powder coating 50 micron) 58 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating notless than grade AC 10 as per IS : 1868) transparent or dyed to required colour orshade, with necessary screws etc. complete:125 mm 59 Providing and fixing aluminium extruded section body tubular type universalhydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body,door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), withdouble speed adjustment with necessary accessories and screws etc. complete. 60 Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised(anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed torequired colour and shade, with necessary screws etc. complete.Twin rubber stopper 61 Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating notless than grade AC 10 as per : 1868), transparent or dyed to required colour or shade,with necessary screws complete:200x10 mm 62 Providing and fixing glazing in aluminium door, window, ventilator shutters andpartitions etc. with EPDM rubber / neoprene gasket etc. complete as per thearchitectural drawings and the directions of Engineer - in -Charge. ( Cost ofaluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mmthickness 63 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating notless than grade AC 10 as per IS : 1868) transparent or dyed to required colour orshade, with necessary screws etc. complete:75 mm 64 Providing and fixing 12 mm thick prelaminated particle board flat pressed three layeror graded wood particle board conforming to IS : 12823 Grade I Type II, in panellingfixed in aluminum doors, windows shutters and partition frames with C.P. brass /stainless steel screws etc. complete as per architectural drawings and directions ofEngineer - in- Charge.Pre- laminated particle board with decorative lamination onboth sides 65 Providing and fixing 100 mm brass locks ( best make of approved quality ) foraluminium doors including necessary cutting and making good etc. complete. 66 Providing and fixing glazing in door, window, ventilator shutters and partitions etc.with EPDM rubber /neoprene gasket etc. complete as per the architectural drawingsand the directions of engineer-in-charge . (Cost of aluminium snap beading shall bepaid in basic item): toughened glass of 6 mm thickness. 67 Providing and fixing frosted film in the fixed glass etc. Complete as per the directionof departmental officers 68 FALSE CEILING 69 Providing and fixing false ceiling at all height including providing and fixing of framework made of special sections, power pressed from M.S. sheets and galvanized withzinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting ofangle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mmdia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangersof 25x10x0.50 mm of required length with nuts & bolts of required size and other endof angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at thespacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thickbottom wedge of 80mm with tapered flanges of 26 mm each having lips of 10.5 mm,at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I.intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm longG.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mmhigh having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed towall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wallscrews @ 230 mm interval, including fixing of gypsum board to ceiling section andperimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c,including jointing and finishing to a flush finish of tapered and square edges of theboard with recommended jointing compound, jointing tapes, finishing with jointingcompound in 3 layers covering upto 150 mm on both sides of joint and two coats ofprimer suitable for board, all as per manufacturers specification and also includingthe cost of making openings for light fittings, grills, diffusers, cutouts made withframe of perimeter channels suitably fixed, all complete as per drawings, specificationand direction of the Engineer in Charge but excluding the cost of painting with:12.5mm thick tapered edge gypsum moisture resistant board 70 Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm intrue horizontal level, suspended on inter locking metal grid of hot dipped galvanizedsteel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting ofmain T runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to centerand cross T of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mmlong spaced between main T at 600 mm center to center to form a grid of 1200x600mm and secondary cross T of length 600 mm and size 24x25 mm made of 0.30 mmthick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to formgrids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceilingtiles of approved texture in the grid including, required cutting/making, opening forservices like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main Trunners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GIadjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at1200 mm center to center along main T, bottom exposed width of 24 mm of all T sections shall be pre-painted with polyester paint, all complete for all heights as perspecifications, drawings and as directed by Engineer -in-charge.GI Metal Ceiling Layin perforated Tegular global white color tiles of size 595x595 mm and 0.5mm thickwith 8 mm drop; made of GI sheet having glavanizing of 100 gms/ sqm (both sidesinclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (NoiseReduction Coefficient) of 0.5, electro statically polyster powder coated of thickness60 microns (minimum), including factory painted after bending and perforation, andbacked with a black Glass fiber acoustical fleece. 71 STEEL WORK 72 Providing and fixing M.S. Grills of required pattern in frames of windows etc. withM.S. flats, square or round bars etc. including priming coat with approved steelprimer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc 73 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trussesetc., including cutting, hoisting, fixing position and applying a priming coat ofapproved steel primer, including welding and bolted with special shaped washers etc.complete.Hot finished welded type tubes 74 Structural steel work riveted, bolted or welded in built up sections, trusses and framedwork, including cutting, hoisting, fixing in position and applying a priming coat ofapproved steel primer all complete. 75 Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angleiron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittingscomplete, including applying a priming coat of approved steel primer.Using M.S.angels 40x40x6 mm for diagonal braces 76 Designing, fabricating, testing, installing and fixing in position Curtain Wall withAluminium Composite Panel Cladding, with open grooves for linear as well ascurvilinear portions of the building , for all heights and all levels etc. including: a)Structural analysis & design and preparation of shop drawings for pressureequalisation or rain screen principle as required, proper drainage of water to make itwatertight including checking of all the structural and functional design. b) Providing,fabricating and supplying and fixing panels of aluminium composite panel cladding inpan shape in metalic colour of approved shades made out of 4mm thick aluminiumcomposite panel material consisting of 3mm thick FR grade mineral core sandwichedbetween two Alumini um sheets (each0.5mm thick). The aluminium composite panelcladding sheet shall be coil coated, with Kynar 500based PVDF / Lumiflon basedfluoropolymer resin coating of approved colour and shade on face # 1 and polymer(Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts,washers, cleats, weather silicone sealant, backer rods etc. c) The fastening brackets ofAluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serratedwashers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts ofapproved make in SS 316, Nylon separators to prevent bi-metallic contacts allcomplete required to perform as per specification and drawing The item includes costof all material & labour component, the cost of all mock ups at site, cost of allsamples of the individual components for testing in an approved laboratory, field testson the assembled working curtain wall with aluminium composite panel cladding,cleaning and protection of the curtain wall with aluminium composite panel claddingtill the handing over of the building for occupation. Base frame work for ACPcladding is payable under the relevant aluminium item.s The Contractor shall providecurtain wall with aluminium composite panel cladding, having all the performancecharacteristics all complete , as per the Architectural drawings, as per itemdescription, as specified, as per the approved shop drawings and as directed by theEngineer-in-Charge. However, for the purpose of payment, only the actual area on theexternal face of the curtain wall with Aluminum Composite Panel Cladding(including width of groove) shall be measured in sqm. up to two decimal places. 77 MULTIWOOD WORKS 78 Providing and fixing panelling or Providing and fixing panelled or Making Shelf,Racks, Tables, etc : 19 mm thick Marine Ply wood with 1 mm thick laminate pastedand pressed with adhesive to give a uniform and smooth finish with 25 year warranty.(Area of opening for panel excluding portion inside grooves or rebates to bemeasured, no extra shall be paid for making openings, door / window frames andmaking provisions for electric conduits.) Shades, design, etc. as per the direction ofsite-in-charge 79 Providing and fixing 4 mm thick Veneer on plywood cupboard/reception counter/wardrobes etc. of approved make with necessary adhesive, complete as per directionof Engineer-inCharge. 80 Providing and fixing panelling or Providing and fixing panelled or Making Shelf,Racks, Tables, etc : 25 mm thick Marine Ply wood with 1 mm thick laminate pastedand pressed with adhesive to give a uniform and smooth finish. (Area of opening forpanel excluding portion inside grooves or rebates to be measured, no extra shall bepaid for making openings, door / window frames and making provisions for electricconduits.) Shades, design, etc. as per the direction of site-in-charge. 81 Providing and fixing 40mm thick cladding comprising of Wooden framework using25x50mm sections at a maximum spacing of 600mm in any one direction (includingadding members as required) covered with 12mm thick BWP ply layered with 4mmthk. veneer on one side pasted and pressed with adhesive to give a uniform andsmooth finish. including 4mm thk. S.S. strip framework on all sides of veneer panelswith wooden member surround, top moldings / margins, excluding primer and polishetc. to finish the thickness, as shown complete in drawing. All members / ply etc.shall be treated with anti- termite solution as per norms. No extra shall be paid formaking of openings, door / window frames and for making provisions for electricconduits.Details of cost for 10sqmAdd wastage @ 20% 82 Providing and fixing Thomson Multi wood board or equivalent make, in shelves withscrews and fittings wherever required, edges to be painted with polyurethane primer(fittings to be paid separately) as per the direction of site Engineer-in-charge. 83 Providing and fixing concealed hinge of approved quality for 19-20mm thick doorwith stainless steel screws complete : 84 Providing and fixing special quality bright finished brass cupboard or ward robe lockswith four levers of approved quality including necessary screws etc. complete.40 mm 85 Providing and fixing magnetic catcher of approved quality in cupboard/ward robeshutters, including fixing with necessary screws etc. complete.Triple strip verticaltype 86 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating notless than grade AC 10 as per IS : 1868) transparent or dyed to required colour orshade, with necessary screws etc. complete:75 mm 87 ROOFING 88 Supply Installation Testing & Commissioning (SITC) of color coated PUFroofing sheet with powder coated Galvanized Iron of 0.4 mm thick sheet on bothsides, 20 mm thick class O PUF sheetof size 40x35cm, min.40kg/m3density sandwiched in between. The surface shall be coated with 80-micron thickpowder coating by hot dip galvanizing with zinc coating not less than 180gm/sqmboth side of the panel. Scope includes runner, covings, interconnecting profiles, fixingarrangements, silicon sealant application and all other accessories required tocomplete the work as per site requirement, Silicon Sealant (Clear/White/WinselGray), complete with all necessary hardware, accessories, fittings and fixtures, as perdescription in individual items, technical specifications, drawings and instructions ofthe Engineer-In charge. 89 PAINTING 90 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare thesurface even and smooth complete. 91 Providing and applying plaster of paris putty of 2 mm thickness over plastered surfaceto prepare the surface even and smooth complete. 92 Finishing with Deluxe Multi surface paint system for interiors and exteriors usingprimer as per manufacturers specifications:Two or more coats applied on walls @1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10sqm 93 Finishing with Deluxe Multi surface paint system for interiors and exteriors usingprimer as per manufacturers specifications:Painting Steel work with Deluxe MultiSurface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqmover an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand andmanufacture 94 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additivesof required shade:New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over andincluding priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) 95 Melamine polishing on wood work ( one or more coat) 96 Removing white or colour wash by scrapping and sand papering and preparing thesurface smooth including necessary repairs to scratches etc. complete. 97 PLUMBING 98 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32mm C.P. brass waste of standard pattern, including painting of fittings and brackets,cutting and making good the walls wherever require:White Vitreous China Flat backwash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap 99 Flexible pipe40 mm dia 100 Providing and fixing PTMT Waste Coupling for wash basin and sink, of approvedquality and colour.Waste coupling 31 mm dia of 79 mm length and 62 mm breadthweighing not less than 45 gms 101 Providing and fixing PTMT Bottle Trap for Wash basin and sink.Bottle trap 31 mmsingle piece moulded with height of 270 mm, effective length of tail pipe 260 mmfrom the center of the waste coupling, 77 mm breadth with 25 mm minimum waterseal, weighing not less than 260 gms 102 Providing and fixing white vitreous china pedestal type water closet (European typeW.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, includingflush pipe, with manually controlled device (handle lever), conforming to IS : 7231,with all fittings and fixtures complete, including cutting and making good the wallsand floors wherever required:W.C. pan with ISI marked white solid plastic seat andlid 103 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply, including all CPVC plain & brass threadedfittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing ofpipes& fittings, with one step CPVC solvent cement and the cost of cutting chasesand making good the same including testing of joints complete as per direction ofEngineer-in-Charge.Concealed work, including cutting chases and making good thewall etc.20 mm nominal outer dia pipes 104 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply, including all CPVC plain & brass threadedfittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing ofpipes& fittings, with one step CPVC solvent cement and the cost of cutting chasesand making good the same including testing of joints complete as per direction ofEngineer-in-Charge.Concealed work, including cutting chases and making good thewall etc.32 mm nominal outer dia pipes 105 Providing and fixing ball valve (brass) of approved quality, High or low pressure,with plastic floats complete:15 mm nominal bore 106 Providing and fixing ball valve (brass) of approved quality, High or low pressure,with plastic floats complete:20 mm nominal bore 107 Providing and fixing C.P. brass long body bib cock of approved quality conforming toIS standards and weighing not less than 690 gms.15 mm nominal bore 108 Providing and fixing PTMT extension nipple for water thank pipe, fittings ofapproved quality and colour .20 mm nominal bore, weighing not less than 40 gms 109 Providing and fixing PVC pipes includings jointing of pipes with one step PVCsolvent cement, trenching, refilling & testing of Joints complete as per direction ofengineer in charge.110 mm dia 6Kgf/cm2 110 Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00m spacing . This includes jointing of pipes with one step PVC solvent cement andtesting of joints complete as per direction of Engineer-in-Charge 110 mm dia 6Kgf/cm2 - External work- Exposed on wall 111 Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make )including cost of materials and labour charges etc complete as per the direction of siteEngineer-in-charge. 112 Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, Collarand bush approved quality and colour .15 mm nominal bore with 45 cm length 113 Providing and fixing C.P. brass angle valve for basin mixer and geyser points ofapproved quality conforming to IS: 893115 mm nominal bore 114 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing . This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge 50 mmdia 6 Kgf/cm2 - Internal work- Exposed on wall 115 Providing and fixing C.P brass long nose bib cock of approved quality conforming toIS standards and weighing not less than 810 gms.15 mm nominal bore 116 Constructing soak pit 1.20x1.20 m filled with brickbats including S.W. drain pipe 100mm diameter and 1.20 m long complete as per standard design. 117 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approvedquality) complete with 6 mm thick hard board ground fixed to wooden cleats withC.P. brass screws and washers complete. 118 Supplying and fixing Stainless steel soap dish including cost of materials and labourcharges etc complete as per the direction of site Engineer-in-charge. 119 Supplying and fixing CP Towel rod 45cm or nearest available length including cost ofmaterials and labour charges etc complete as per the direction of site Engineer-in charge. 120 Providing and fixing square rain water gutter pipes including jointing.<br>150mm diameter 121 SIGNAGES 122 NAME BOARD ACP SHEET WITH MULTIWOOD LETTERING : Design,Supplying andfixing Name Board as per the technical specifications given -1 Inch GI pipe frame(16Guage) for Frame (Sizeproportional), Primer Paint & Black Painted Pipes for Frame.,5mm ACP sheets(Aluminum Composite Panel)for Box area, 18mm thick Multi wood Lettering for Name Board as approvedby Engineer incharge.For Measurement purpose, only area of ACP sheet to be measured 123 Design, providing and fixing Digital Printed vinyl signage boards with transparent3mm acrylic Sheet with 4 nos. SS Studs with lettering of size 15x45 cm. Complete asper the per the direction of Engineer in charge. 124 Providing and fixing up Multiwood Letter of Size 7 Inch Height & WidthProportional, over any surface as per the direction of site engineer in charge. Rateinclusive of labour, adhesives, etc. 125 Electrical 126 POINT WIRING 127 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group B 128 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C 129 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C 130 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. 131 CIRCUIT WIRING 132 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire 133 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 134 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire 135 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 6 sq. mm + 2 X 6 sq. mm earth wire 136 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm 137 accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm 138 SWITCHES AND SOCKETS 139 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch 140 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet 141 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch 142 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet 143 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 144 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) 145 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm) 146 Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A SP switch with indicator 147 Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket 148 Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )3 module moulded plastic box on surface 149 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module 150 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required Bell push 151 DB, ENCLOSURE 152 Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) 153 Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+24) - three phase double cover (IP 42/43) 154 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator16 way, Double door 155 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps 156 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole 157 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker with overcurrent protection (RCBO), having a sensitivity current upto 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40A, 4P, 100mA 158 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current breaker with overload (RCBO), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required 25A, 2P, 30mA 159 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 160 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 161 Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps DP Isolator complete with connections, testing and commissioning etc. as required. 162 CABLE SUPPLY ,LAYING AND TERMINATION 163 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp 164 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp 165 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp 166 Supplying and making end termination with brass compression gland and aluminiumlugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm) 167 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) 168 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm) 169 EARTHING PROTECTION 170 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required 171 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG) 172 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) 173 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG) 174 LIGHT AND FAN FIXTURES 175 SITC of 36 W (+/-2) high efficient recess mounted 600mm x 600mm soft glowing LED luminaire with system light output greater than 3600 lumens and system efficacy >110 lm/W, UGR<19. The luminaire must be energy efficient with CRI>80, CCT – 6500K, pf > 0.95, THD <10% SDCM<5, IP20 protection. The luminaire shall be flicker free with a ripple content less than 5 %. The luminaire must be BIS certified and must have LM79 and LM80 reports from NABL certified labs. The luminaire housing shall be made of CRCA and prismatic polystyrene diffuser with high transparency coefficient and a lifetime of 50,000 burning hours as per L70B50 criteria, 2.5 kV internal surge protection, including all accessories necessary as required to complete installation. 176 SITC of 10 W (+/-2) high efficient recess mounted LED circular/square down lighter with white powder coated, pressure die cast aluminum housing, a polycarbonate diffuser and a sleek design of product height not more than 40 mm. The luminaire shall have a CCT of 6500 K, CRI>80, power factor>0.9 and THD <10 %. The luminaire shall be EMI/ EMC compliant. The luminaire and driver shall be BIS approved and test certificates of LM79 and LM80 reports shall be submitted. The luminaire shall have a non-integral LED driver with 50,000 burning hours as per L70B50 criteria, ambient temp-0 to 45 o C, 2.5 kV surge protection, and inbuilt electronic driver, luminaire efficacy > 110 lm/W including all accessories necessary as required to complete installation. 177 SITC of 4 feet surface mounted batten type luminaire with a power consumption not more than 20 W, luminaire lumen output of 2400 lumens, luminaire efficacy > 120 lm/W with an operating voltage range from 140 V - 270 V. The luminaire shall have a white CRCA housing with a poly carbonate diffuser to provide uniform light and a sleek design with width not more than . The luminaire shall have a CCT of 4000K ,6500 K , CRI > 80, power factor >0.95, SDCM < 5, THD <10% and 50,000 burning hours as per L70B50 criteria. The luminaire shall have flicker content <5% and shall have high and low cut off with auto restart feature. The luminaire shall be EMI/ EMC compliant and shall have a internal surge protection of 4 kV. The luminaire shall have Class - 1 Electrical Insulation, Class - B Serviceability (The driver can be replaced at site level). The luminaire and driver shall be BIS approved and test certificates of LM79 and LM80 reports from NABL accredited labs. 178 SITC of 2 feet surface mounted batten type luminaire with a power consumption not more than 10 W, luminaire lumen output of 1200 lumens, luminaire efficacy > 120 lm/W with an operating voltage range from 140 V - 270 V. The luminaire shall have a white CRCA housing with a poly carbonate diffuser to provide uniform light and a sleek design with width not more than . The luminaire shall have a CCT of 4000K ,6500 K , CRI > 80, power factor >0.95, SDCM < 5, THD <10% and 50,000 burning hours as per L70B50 criteria. The luminaire shall have flicker content <5% and shall have high and low cut off with auto restart feature. The luminaireshall be EMI/ EMC compliant and shall have a internal surge protection of 4 kV. The luminaire shall have Class - 1 Electrical Insulation, Class - B Serviceability (The driver can be replaced at site level). The luminaire and driver shall be BIS approved and test certificates of LM79 and LM80 reports from NABL accredited labs. 179 SITC of EXHAUST FAN,SHUTTER TYPE white colour, 9 OR 10 star rated as per BEE complete with its all accessories including mounting accessories. 180 Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply 181 UPS 182 Supply installation, testing and commissioning of following single phase to single phase 6KVA UPS with inbuilt battery backup, indoor (IP20) in stand alone configuration, true online double conversion DSP based UPS system, with 30 min backup battery with, input pf>.9, less input current consumption, with input 230V single phase, output 230V single phase , IGBT rectifier and IGBT inverter. It shall be 100% generator compatible with efficiency > 90% and output power factor > 0.8 and including all accessories etc as required. The UPS system shall be with manual maintenance bypass switch facility. The system shall comply to IEC /EN 62040-1 and relevant IS standard and.The acoustic noise of the system should be less than 58dB. The system shall comply to IEC /EN 62040-1, EN/IEC 62040-2, EN/IEC 62040-3 and relevant IS standard. 6kVA UPS - 1 Nos, Battery Circuit Breaker-1 nos, Battery Required nos. of SMF for providing 30 Minutes Backup and Battery Accessories like battery rack, interconnecting cables etc. 183 DISMANTLING 184 Electrical Labour works Dismantling of existing ceiling fan, light fittings, Switch Boards, DB Boards (SPN &TPN) using mechanical means or physical means without disturbing the overall structure of proposed area. All items dismantled and shall be made a checklist for returning back to concerned Authorities. All items shall be verified by ElectricalEngineer (HLL) before handing over. If any working product is damaged during transit, the same shall be replaced without any additional claim. 185 Dismantling of existing meter board, removing and rewiring the connections to the meter board after informing the KSEB authorities about meter shifting. 186 Dismantling of ceiling fan and painting the same with with one or more coats of spray painting with synthetic enamel paint of approved brand and manufacture to give an even shade, including cleaning of surface with detergent and replacing the damaged rubber reel, nuts and bolts with washers and safety pins reinstalling the same as required. 187 Dismantling, re installation and commissioning of HiWall Split AC (IDU and ODU) units (1.0TR/1.5TR/2.0TR) with water service, gas top up, including all necessary fittings for recommissioning complete as required as per the direction of Engineer in charge. 188 DOCUMENTATION AND APPROVAL 189 DOCUMENTATION AND APPROVAL - Charges for Preparation of all drawings submitting and getting approval from KSEB, submitting of Completion certificates and arranging inspection, getting sanction from KSEB, obtaining power allocation if necessary & power connection etc. for commissioning of the whole installation in the premises. All statutory payments will be reimbursed on production of the original receipts 190 PA SYSTEM 191 Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required.speaker cable Two pair, 2-core, 1.5 sqmm 192 SITC OF Light weight Potable Tripod projector stand omes with a fold-up tray that provides a secure tilting platform for most projectors. Its tilt adjustment ensures optimal viewing angles. Removable tray quickly detaches to easily pack into theincluded nylon carry bag. The included straps add additional support and safety. Retractable folding tripod legs with locking paddles are ideal for transport and storage. Built-in bubble level keeps proper leveling. Anti-skid feet ensure stability and prevent the surface from scratches. This stand can also support other devices including laptops, cameras, tablets and DJ equipment. Perfect for home, offices, camps, presentations, stage and other applications 193 SITC OF Professional 3-Way 250 w speaker system consisting of one high efficiency, high SPL 15” LF speaker, a 1” HF Compression Driver and two Piezo Tweeters, for excellent high frequency response. The speaker system has a high efficiency that makes it particularly good value as high levels of acoustic power can be achieved without drawing excessive power from the amplifier. The system is housed in a Rugged Bass Reflex Trapezoidal Enclosure made of 18mm board, and Carpet covered. A Stand Adapter is provided at the bottom for stand mounting. The trapezoidal cabinet design assures optimum low frequency performance. An On/Off switch for the piezo speakers is provided to limit extended HF if desired. The speaker is ideal for PA as well as music performances. 194 SITC OF Professional high quality PA Gooseneck Microphones are suitable for various PA applications such as on Lecterns and Podiums, Open Conferences etc. The sleek and slender design makes the microphones unobtrusive. fitted with stand mount base and are supplied with 6 mtrs twin core shielded low noise cable.Wide frequency response.High front-to-back rejection for more gain before feedback.Built-in XLR socket. Frequency Response 50-15,000Hz Impedance 500 Sensitivity 2.2mV/Pa Overall Length 395mm (15½”) 195 SITC OF 1000 Watts High Wattage PA Power Amplifier with Line Input 200mV/1V switchable for connecting a mixer or another amplifier.100V input for connecting another amplifier output. Resettable circuit breaker for protection against overload and short circuit. 196 Brightness, 20000:1 High Contrast Ratio, Dual Hdmi, Upto 15000 Hrs Extra-Long Lamp Life, 10W Speaker, 3D Capable, White Connectivity Technology with VGA, USB, HDMI Display resolution1280 x 800 native resolution 1280 x 800 light source life 15000 hours 197 Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable 198 NETWORKING AND TELEPHONE 199 Supply, installation, testing and commissioning of CAT6A Information Outlet, RJ45 with all accessoriesrequired at site to complete the work as per technical specification 200 Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required2 run of Cable 201 Supply,Installation,Testing &Commissioning of CAT6 Patch Cord with Moulded boots Over-moulded boot at each end provide strain relief and maintains minimum bend radius of the cable.- 2Meter 202 Supply, Installation, Testing & Commissioning of 8 Port Network Switch with 8 Nos of 10/100/1000 ports and 2 Gigabit Copper/ SFP Combo ports for uplink 203 Supply, Installation, Testing & Commissioning of 6U Network Rack with below specifications as minimum and all the necessary accessories: - Lock & Keys - Tray (1 No) - 1 Cooling Fan and Adjustable Shelf - Height - 6U - Fan Units with 1coolin Fans - PDU point - Mounting Hardware Kit (1 lot) - Tray - Front glass doors and back steel door and side panels 204 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module 205 SITC Of Krone Box 10 Pair 206 Supply, Installation, Integration and Commissioning of 8 Lines EPABX Intercom System along with krone module as per the direction from Engineer in charge 207 Supply of User Phone- Analog phone 208 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet 209 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.2 Pair 210 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.TV antenna socket outlet 211 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. 212 AIR CONDITIONING 213 Supply and fixing of M.S OUTDOOR STAND for Split ACs. The work involves supply of heavy duty powder coated mounting bracket for outdoor unit with mounting bolts, complete as required and as directed by the Engr.-in-Charge 214 Supply & installation of STABILIZER suitable for 2.0TR Capacity Split AC units inclusive of all necessary wiring/connection. Stabilizer should comply with the detailed specification mentioned below. Intelligent Time Delay System, Latest IC Technology - Assures reliable protection, Wall Mounting Cabinet Design - Elegant and easy to install, Low & High Voltage cut-off Protection, Built-In Thermal Overload Protection - Protects the stabilizer and compressors during high-temperature burnout, Working Rage Voltage 170 VAC - 270 VAC.Make: V Guard/Vstab / Microtek or Equivalent with ISI Standard. 215 Supply & installation of Stabilizer suitable for 1.0TR/1.5TR Capacity Split AC units inclusive of all necessary wiring/connection. Stabilizer should comply with the detailed specification mentioned below. Intelligent Time Delay System, Latest IC Technology - Assures reliable protection, Wall Mounting Cabinet Design - Elegant and easy to install, Low & High Voltage cut-off Protection, Built-In Thermal Overload Protection - Protects the stabilizer and compressors during high-temperature burnout, Working Rage Voltage 170 VAC - 270 VAC Make: V-Guard/Vstab / Microtek or Equivalent with ISI Standard. 216 Drain Piping for Split ACs: Supply & installation of PVC insulated piping for condensate drain Including wall chasing, necessary supports, Clamps etc complete as required 217 Additional refrigerant Copper piping Kit for Split ACs : Supplying and installation of additional refrigerant piping kit consisting of power and control cables, good quality copper tubing, Elastomeric Nitrile rubber insulation etc. for Split AC units. 218 Supply, Installation, Testing and Commissioning of 2.0TR - 3 Star rated Inverter type split AC units , Hi-wall mounted, preferably with anti corrosive / powder coated outdoor units, fitted with hermitically sealed suction cooled energy efficient Scroll / Rotary compressor operating on R-32 / HFC-134a / 407 C / 410 A refrigerant suitable for operation on 220 V, 1 Ph, 50 Hz A/C supply. The units shall be inclusive of all standard accessories like power & control cables, good quality copper tubing of minimum 3 meter length to interconnect the outdoor unit with indoor unit for refrigerant lines, elastomeric Nitrile rubber insulation, clamps etc. Notes: (1) Condenser tubes, Evaporator tubes & connecting pipes should be made out of good quality copper. (2) High-energy efficient compressor of rotary / Scroll type (3) Cordless remote for setting Temp, on time, off time, power saving mode, auto mode operation, sleep mode, auto setting with memory backup, time delay feature, programmable timer, etc. with real time clock. (4) Warranty: 5 Years on PCB, 10 years warranty on compressor and one year warranty for the total system from the date of handing over/ commissioning Make: Blue Star / Voltas / Carrier Midea / Hitachi / Daikin / Panasonic / Mitsubishi / Toshiba / Trane / O General or equivalent 219 Supply, Installation, Testing and Commissioning of 1.5TR - 3 Star rated Inverter type split AC units , Hi-wall mounted, preferably with anti corrosive / powder coated outdoor units, fitted with hermitically sealed suction cooled energy efficient Scroll / Rotary compressor operating on R-32 / HFC-134a / 407 C / 410 A refrigerant suitable for operation on 220 V, 1 Ph, 50 Hz A/C supply. The units shall be inclusive of all standard accessories like power & control cables, good quality copper tubing of minimum 3 meter length to interconnect the outdoor unit with indoor unit for refrigerant lines, elastomeric Nitrile rubber insulation, clamps etc. Notes: (1) Condenser tubes, Evaporator tubes & connecting pipes should be made out of good quality copper. (2) High-energy efficient compressor of rotary / Scroll type (3) Cordless remote for setting Temp, on time, off time, power saving mode, auto mode operation, sleep mode, auto setting with memory backup, time delay feature, programmable timer, etc. with real time clock. (4) Warranty: 5 Years on PCB, 10 years warranty on compressor and one year warranty for the total system from the date of handing over/ commissioning Make: Blue Star / Voltas / Carrier Midea / Hitachi / Daikin / Panasonic / Mitsubishi / Toshiba / Trane / O General or equivalent
Contract Date : 02 Aug, 2025   |   Contract Value : 5.68 Lakhs
BRR : 8000609 Supply Of Escalatorsescalators,Design, Manufacture, Supply At Site, Installation ,Testing And Commissioning Of Heavy Duty Passe Nger Escalators Along With Energy Meter At Kasaragod Railway Station In Pf No. 1 & 2/3 And Shall Be Supplied In Accordance With The Requirements Of The Site, As Furnished In The Annexure-I. The Escalator Shall Be As Per The R Dso Specification No.Rdso/Pe/Spec/Tl/0095 (Rev 3) -2019. Warranty: 24 Months From The Date Of Commissioni Ng. During Warranty Period, All Scheduled Maintenance (As Per Rdso Specification No. Rdso/Pe/Spec/Tl/0095 ( Rev 3) -2019, Annexure-6 Check List ) Must Be Performed For Which No Extra Payment Will Be Made. [ Warrant Y Period: 30 Months After The Date Of Delivery ] ] , Post Warranty Comprehensive Annual Maintenance Charges (After 2 Year Free Warr Anty Period) - Firm To Quote Separately For Each Camc Year Ie: Year 1 Tab (For 3Rd Year), Year 2 Ta B (For 4Th Year), Year 3 Tab (For 5Th Year),Year 4Th Tab (For 6Th Year), Year 5Th Tab(For 7Th Year). Fir M Should Quote The Actual Rate Of The Camc In The Bid, Discounted Rate As Per Npv Will Be Generated B Y The Ireps System For Ranking Purpose [ Warranty Period: 2 Years, Amc Period: 5 Years, Rate Of Discoun Ting: 10 % ] ] At (Location) Sse/E/W/Pgt, Sr Kerala 4.00 Numbers Group 3280070-Heavy Duty Passenger Escalators For Kannur Railway Station 1 479023280070 Basic Non Stock --- Yes Tpi Agency Inr (3280070) Machine (Y) Design, Manufacture, Supply At Site, Installation ,Testing And Commissioning Of Heavy Duty Passe Nger Escalators Along With Energy Meter At Kannur Railway Station In Pf No. 1 & 2/3 And Shall Be Supplied In Acc Ordance With The Requirements Of The Site, As Furnished In The Annexure-I. The Escalator Shall Be As Per The Rds O Specification No.Rdso/Pe/Spec/Tl/0095 (Rev 3) -2019. Warranty: 24 Months From The Date Of Commissioning . During Warranty Period, All Scheduled Maintenance (As Per Rdso Specification No. Rdso/Pe/Spec/Tl/0095 (Re V 3) -2019, Annexure-6 Check List ) Must Be Performed For Which No Extra Payment Will Be Made. Note: The Fir M Shall Provide A Separate Quote For A Comprehensive Annual Maintenance Contract For Five Years, As Per The Ca Mc Conditions Enclosed. [ Warranty Period: 30 Months After The Date Of Delivery ] ] Consignee Sse/E/W/Pgt, Sr Kerala 3.00 Numbers Inspection Details Stage Inspection Not Required Page 1 Of 19 Run Date/Time: 06/06/2025 12:02:48Pgt Div/Southern Rly Tender Document Tender No 91255470 Closing Date/Time 01/07/2025 14:30 2 4790232800701 Amc (Y) Non Stock --- Yes Consignee Inr (3280070) Post Warranty Comprehensive Annual Maintenance Charges (After 2 Year Free Warr Anty Period) - Firm To Quote Separately For Each Camc Year Ie: Year 1 Tab (For 3Rd Year), Year 2 Ta B (For 4Th Year), Year 3 Tab (For 5Th Year),Year 4Th Tab (For 6Th Year), Year 5Th Tab(For 7Th Year). Fir M Should Quote The Actual Rate Of The Camc In The Bid, Discounted Rate As Per Npv Will Be Generated B Y The Ireps System For Ranking Purpose. [ Warranty Period: 2 Years, Amc Period: 5 Years, Rate Of Discoun Ting: 10 % ] ] At (Location) Sse/E/W/Pgt, Sr Kerala 3.00 Numbers 3. T And C F.O.R Description Destination Delivery Period Description Delivery /Completion Rate Of Supply For All Items Completion : Within 90 Days 1) Firm Should Provide Final Gad, Bill Of Material And Etc. As Per Specification For The Approval Of Srdee/G/Pgt Within 15 Days From The Date Of Release Of Purchase Order. 2) Supply Should Be Completed Within 30 Days From The Date Of Approval Of Final Gad, Bom And Etc.. 3) Installation And Commissioning To Be Completed Within 45 Days From The Date Of Approval Of Final Gad And Bom. Payment Terms S.No Description Payment Terms 1 1) The Payment Shall Be Made By The Concerned Accounts Oï¬Ƒcers Of The Division Where The Escalators Has Been Commissioned I.E. Sr.Dfm/Pgt. Payment Shall Be Made As Under: 70% Payment Will Be Allowed After Receipt Of The Machine In Good And Acceptable Condition At Consignees End Against Proof Of Receipt Of Material By The Consignee & Routine Test Reports By The Contractors In-House Qc, Duly Approved By The Purchaser Or Their Authorized Representative. Balance 30% Payment Will Be Made After Complete Installation, Commissioning And Testing Of The Escalator As Per Test Protocol Given In Proforma C Of Annexure-3 Of Rdso Speciï¬Cation And Acceptance As Certiï¬Ed By The User Department At The Level Of Gazetted Oï¬Ƒcer After Submitting Of Security Deposit In The Form Of Bank Guarantee Of 5 % Value Of The Stores Supplied And Commissioned Towards Warranty As Per Para 22 Of Rdso Speciï¬Cation. The Above Mentioned Bank Guarantee Shall Be Released After The Expiry Of The Warranty Period. Bank Guarantee Should Be Handed Over Directly To Consignee Gazetted Oï¬Ƒcer And To Be Kept In The Custody Of Associate Finance I.E Sr.Dfm/Pgt. Payment Terms Mentioned Any Where In The Tender/ Speciï¬Cation Document Should Be Read As Above. 2) Final Payment Made Only Based On The Vertical Height Variation Clause. 2 Payment Conditions For Camc Period: Payment Shall Be Made To The Contractor Quarterly After Successful Completion Of Maintenance Of The Escalator Including Replacement Of Must Change Items For A Period Of Three Months Carried Out As Per Service Reports Duly Signed By The Contractors Representative And Railways Authorized Representative. This Payment Shall Be Made After Submission Of Bill In Railways Standard Bill Form And Going Into All The Railways Formalities Viz Signing Of Agreement, Recording Of Mbook Etc. 3 The Contractor Shall Be Responsible For Any Damage To Equipment Provided In The Escalator, Due To Defective Design, Materials, Workmanship For A Period Of 24 Months From The Date Of Commissioning Of Escalator And 30 Months From The Date Of Supply, Whichever Is Earlier. Statutory Variation Clause S.No Description Page 2 Of 19 Run Date/Time: 06/06/2025 12:02:48Pgt Div/Southern Rly Tender Document Tender No 91255470 Closing Date/Time 01/07/2025 14:30 1 Statutory Variation In Taxes And Duties, Or Fresh Imposition Of Taxes And Duties By State/ Central Governments In Respect Of The Items Stipulated In The Contract (And Not The Raw Materials Thereof), Within The Original Delivery Period Stipulated In The Contract, Or Last Unconditionally Extended Delivery Period Shall Be To Railways Account. Only Such Variation Shall Be Admissible Which Takes Place After The Submission Of Bid. No Claim On Account Of Statutory Variation In Respect Of Existing Tax/Duty Will Be Accepted Unless The Tenderer Has Clearly Indicated In His OffEr The Rate Of Tax/Duty Considered In His Quoted Rate. No Claim On Account Of Statutory Variation Shall Be Admissible On Account Of Misclassification By The Supplier/ Contractor. Option Clause S.No Description 1 In Terms Of Railway Board Lr. No. 2021/Rs(G)/779/5 Dt. 04/03/22, The Purchaser Shall Be Entitled To Vary The Total Order Quantity Upto + 30% Anytime Within The Delivery Period (Including Extended Delivery Period And Even At The Time Of Ordering) By Giving Suitable Notice On The Same Price And Terms And Conditions, Even If The Supply Of Original Ordered Quantity Is Completed Before The Last Date Of Scheduled Delivery. The + 30% Option Clause Can Be Operated In One Or More Than One Installment As Long As The Total Variation In Quantity Does Not Exceed The Limit Of 30% Of Ordered Quantity. For Operation Of (+) 30% Option Clause, The Increase In Quantity With Respect To The Order Quantity Can Be Done By Giving Suitable Delivery Schedule For The Enhanced Quantity And The Tenderer Shall Be Bound To Accept The Quantity So Ordered On The Basis Of His Original OffEr. In Case Letter Of Acceptance Were Issued For Multiple Consignees With The Same All Inclusive Rate, Then Option Clause Will Be Operated Up To 30% Of The Letter Of Acceptance Quantity For Any Of The Consignee. For Details See Para 2.4 To 2.6 Of Part B Of Sr Tender Conditions Attached To This Tender Document. Standard Governing Conditions S.No Description 1 Governing Conditions Of Contract: The Contract Shall Be Governed By 1) Irs Conditions Of Contract, Uploaded On Ireps Website Link Https://Www.Ireps.Gov.In/Ireps/Upload/Repository/Railway/582/161/Private/Revisedirsconditions2022.Pdf. 2) All Other Terms And Conditions Incorporated In The Tender Documents Uploaded On Ireps Website Link (Https://Www.Ireps.Gov.In/Ireps/Upload/Repository/Railway/582/161/Public/Sr_Tender_Conditions_01032024_Sr.Pdf). 4. Eligibility Conditions Special Eligibility Criteria S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Supply To Be As Per The Tender Speciï¬Cation Normal Applicable To Yes Yes Allowed (Enclosed). The Bidders Are Advised To Go All Bidders (Optional) Through All The Clauses Of Rdso Speciï¬Cation As Well As Additions/Alterations To The Speciï¬Cation And Give Their Compliance. 2 A) The Tenderer, Must Have Successfully Normal Applicable To Yes Yes Allowed Completed Any Of The Following During Last All Bidders (Mandatory) 07(Seven) Years, Ending Of Month Previous To The One In Which Tender Is Invited:- Three Similar Works Each Costing Not Less Than The Amount Equal To 30% Of Value Of The Tender, Or, Two Similar Works Each Costing Not Less Than The Amount Equal To 40% Of Value Of The Tender, Or, One Similar Work Each Costing Not Less Than The Amount Equal To 60% Of Value Of The Tender. The Similar Work Here Shall Be Deï¬Ned As Design, Manufacture, Supply, Installation And Commissioning Of Passenger Escalators At Railway Stations Or Metro Stations Or Mono Rail Or High Speed Rail Or Mass Rapid Transport System , Airports Or Any Other Central/State Govt. Controlled / Owned Public Transport, Railway Service Buildings Or In Any Oï¬Ƒce Buildings/Hospitals Of Central Govt./State Govt./Psus Of Central Or State Govt. Firms With Lesser Performance Than Mentioned Above May Be Considered For Developmental Order Provided They Had Submitted Their Past Performance Etc. Along With The Tender Document. As Per The Tender Eligibility Criteria, The Advertised Value Of The Current Tender Is Rs. 4,58,72,619/-. B) Tenderer Has To Upload Attested Supporting Documents/Certiï¬Cates From The Organization With Whom They Have Satisfactorily Completed The Works, Along With Their Offers. Page 3 Of 19 Run Date/Time: 06/06/2025 12:02:48Pgt Div/Southern Rly Tender Document Tender No 91255470 Closing Date/Time 01/07/2025 14:30 3 1) Oems Can Authorize And Give Tender Speciï¬C Normal Applicable To Yes Yes Allowed Authorization To Its Agent / Dealers To Quote On All Bidders (Optional) Their Behalf Provided The Vendor Takes Full Responsibility For The Quality Of The Material Including Warranty Obligation And The Inspection Of Product Against Railways Order Is Carried Out At The Manufacturers Premises.Please Refer Para 3.4 Of Part-B Of Southern Railway Tender Conditions Attached With This Tender. 2) Preferably Manufacturers Should Participate. In Case Of ϬRms Other Than Oems Participating In The Tender, They Must Submit Tender Specific Authorization From Oem. 5. Compliance Conditions Check List S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Have You Attached Any Performance Statements Normal Applicable To No No Not Allowed With Your OffEr? For Proof Of Supply To Other All Bidders Railways / Production Units Copy Of Inspection Certiï¬Cate And Receipt Note / Certiï¬Cate Must Be Uploaded. Non-Submission Of Such Vital Documents May Be Taken As Their Not Having Any Such Past Performance 2 Have You Furnished The Statement Of Normal Applicable To No No Not Allowed Deviations? [Preferably Nil] All Bidders 3 Please Check Our Website Before Submitting Normal Applicable To No No Not Allowed OffEr, Whether Any Corrigendum To The Tender All Bidders Has Been Issued Or Not 4 Have You Kept Your OffEr Valid For 120 Days? Normal Applicable To No No Not Allowed [Validity Of 120 Days Is Required For Items Of All Bidders Machinery And Plants ]. 5 Have You Submitted Authenticated Copy Of The Normal Applicable To No No Not Allowed Document Authorizing The Signatory To Submit All Bidders Offer And Commit On Behalf Of Tenderers Commercial-Compliance S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 1. Goods & Service Tax: Please Refer Part A Para Normal Applicable To Yes No Not Allowed 14.0 Southern Railway Tender Conditions. All Bidders 2. Regarding Mse Purchase Preference Please Refer Clause 15.0 Part B Of Southern Railway Tender Conditions. 3. Preference To Made In India Please Refer Part B Para 16.0 Of Southern Railway Tender Conditions. Page 4 Of 19 Run Date/Time: 06/06/2025 12:02:48Pgt Div/Southern Rly Tender Document Tender No 91255470 Closing Date/Time 01/07/2025 14:30 2 [A] All The Bidders/Tenderers Should Ensure That Normal Applicable To No No Not Allowed They Are Gst Compliant And Their Quoted Tax All Bidders Structure/Rates Are As Per The Gst Law. Firms Must Indicate Its Gst Registration Number Along With Their Offer. [B] In Case The Successful Tenderer Is Not Liable To Be Registered Under Cgst/Igst/Utgst/Sgst Act, The Railway Shall Deduct The Applicable Gst From His/Their Bills Under Reverse Charge Mechanism (Rcm) And Deposit The Same To The Concerned Tax Authority. [C] The ϬRm Should Indicate The Tariff Code (Hsn Code) For Claiming Gst For The Tendered Item. [D] The OffEr Shall Be Evaluated Based On The Gst Rate As Quoted By Each Bidder And Same Will Be Used For Determining The Inter-Se Ranking. While Submitting OffEr, It Shall Be The Responsibility Of The Bidder To Ensure That They Quote Correct Gst Rate And Hsn Number. [E] It Shall Be The Responsibility Of The Bidders To Quote Correct Hsn Number And Corresponding Gst Rate. The Purchaser Shall Not Be Responsible For Any Misclassiï¬Cation Of Hsn Number Or Incorrect Gst Rate, If Quoted By The Bidder. In Case ϬRm Mis-Classiï¬Es Hsn Code/Gst Rate, Higher Gst, If Any, Due To This Misclassiï¬Cation Shall Be Paid And Borne By The Firm Itself. [F] Wherever, The Successful Bidder Invoices The Goods At Gst Rate Or Hsn Number Which Is DiffErent From That Incorporated In The Purchase Order, Payment Shall Be Made As Per Gst Rate Which Is Lower Of The Gst Rate Incorporated In The Purchase Order Or Billed. [G] Vendor Is Informed That She/He Would Be Required To Adjust Her/His Basic Price To The Extent Required By Higher Tax Bill As Per Invoice To Match The All Inclusive Price As Mentioned In The Purchase Order. [H] Any Amendment To Gst Rate Or Hsn Number In The Contract Shall Be As Per The Contractual Conditions And Statutory Amendments In The Quoted Gst Rate And Hsn Number, Under Svc. [I] Tenderers Should Upload Gst Rate Along With Documentary Evidence, Hsn Code And Full Bank Details Of The ϬRm.Ie Bank Name, Bank Address, Account Number, Ifsc Code & Micr Code Along With The Bid. [J] Firm Should Also Give A Declaration That Any Additional Input Tax Credit Beneï¬T, If Become Available To Supplier, The Same Shall Be Passed On To Purchaser Without Any Undue Delay. Page 5 Of 19 Run Date/Time: 06/06/2025 12:02:48Pgt Div/Southern Rly Tender Document Tender No 91255470 Closing Date/Time 01/07/2025 14:30 3 (I) In Case Of Mse ϬRm Willing To Claim The Normal Applicable To Yes Yes Not Allowed Beneï¬Ts Under Public Procurement Policy All Bidders (Preference To Mse) Order 2012, The ϬRm Should Upload With Their OffEr, The Proof Of Their Being Mse Registered With The Agency Mentioned In Part B Para 15.0 Of Southern Railway Tender Conditions, Failing Which Such OffErs Will Not Be Liable For Consideration Of Beneï¬Ts (Ii) As Per Gazette Notiï¬Cation No. S.O.4926(E) Dated 18.10.2022 Amending Notiï¬Cation No. S.O.2119(E) Dated 26.06.2020 Circulated Vide Railway Board Letter No. 2020/Rs(G)/363/1 Dated 03.11.2022 Regarding Reclassiï¬Cation Of Enterprises And Udyam Registration, In Case Of An Upward Change In Terms Of Plant And Machinery Or Equipment Or Turnover Or Both, And Consequent Reclassiï¬Cation, An Enterprise Shall Continue To Avail Of All Non-Tax Beneï¬Ts Of The Category It Was In Before The Reclassiï¬Cation, For A Period Of Three Years From The Date Of Such Upward Change. In Such Cases, The Tenderer Claiming Beneï¬Ts Under Mse Category Shall Submit Documentary Evidence O F The Date Of Upgradation To Medium Category Along With OffEr. Such Claims Will Not Be Considered With Out Documentary Evidence (Iii) Tenderers Shall Upload Udyam Registration Detail Showing That The Enterprise Is Owned By Scheduled Castes (Sc)/ Scheduled Tribes (St)/ Women Entrepreneurs To Claim The Beneï¬T Under This Sub Classification. 4 In Terms Of Railway Boards Letter No. Normal Applicable To Yes Yes Not Allowed 2015/Rs(G)/779/5(Vol.Iii) Dated: 22.06.2020 All Bidders And In Keeping With The Public Procurement (Preference To Make In India) Order, 2017 As Amended, It Has Been Found That There Is Suï¬Ƒcient Local Capacity And Competition In Supply Of The Tendered Item Of Required Quality And Therefore Public Procurement Of This Tendered Item Is Restricted To Class I Local Suppliers Only (Class-I Local Supplier Means A Supplier Or Service Provider, Whose Goods, Services Or Works OffEred For Procurement, Has Local Content Equal To Or More Than 50%). The Class I Local Supplier At The Time Of Bidding Shal Indicate Percentage Of Local Content. The Vendors Who Do Not Qualify To Be Class I Local Suppliers Should Not Quote In The Tender As Their OffErs Shal Not Be Considered For Any Ordering. In Case Any Vendor Who Does Not Qualify To Be A Class I Local Supplier For The Tendered Item Participates In The Tender It Does So At Its Own Risk And Cost And Railways Shal Not Be Liable For Any Loss Or Damage Caused To The Vendor. 5 General Damages At The Rate Of 5% Of The Normal Applicable To Yes Yes Not Allowed Defaulted Contract Order Value Will Be Levied In All Bidders Case Of Failure To Supply The Material After Placement Of Purchase Order, Within The Delivery Period. In Case Of Failure To Comply With The Contractual Obligations, Railways Shall Record Poor Performance Of The Vendors For Taking Suitable Penal Action As Per Extant Instructions. Wherever Sd Has Been Exempted Or Not Applicable For Any Reason Or Is Less Than The General Damages As Indicated Above, And The Supplier Fails To Supply Goods As Per Conditions Of Contract, As Amended From Time To Time, Purchaser Have The Right To Levy Damages From The Supplier For Failing To Comply With Contractual Conditions. These Damages Shall Be Treated As Recoveries Outstanding Against The Vendor And Dealt With Accordingly. Page 6 Of 19 Run Date/Time: 06/06/2025 12:02:48Pgt Div/Southern Rly Tender Document Tender No 91255470 Closing Date/Time 01/07/2025 14:30 6 Liquidated Damage (L.D): Extension Of Delivery Normal Applicable To Yes Yes Not Allowed Period May Be Considered In Deserving Cases All Bidders Where Genuine Reasons Exist. Such Extensions Of Delivery Period May Be Considered With Liquidated Damages As Per Irs Conditions Of Contract And Denial Clause. Railway Shall Recover From The Contractor As Agreed Liquidated Damages And Not By Way Of Penalty, A Sum Equivalent To 1/2% (Half Percent) Of The Price Of Any Stores (Including Elements Of Taxes, Duties, Freight, Etc) Which The Contractor Has Failed To Deliver Within The Period ϬXed For Delivery In The Contract Or As Extended For Each Week Or Part Of A Week During Which The Delivery Of Such Stores May Be In Arrears Where Delivery Thereof Is Accepted After Expiry Of The Aforesaid Period, Subject To A Maximum Of 10% (Ten Percent) Of The Value Of The Contract Irrespective Of Delays, Unless Otherwise Provided Specifically In The Contract. 7 Security Deposit (Sd) Shall Be 5 % Of Total Normal Applicable To Yes Yes Not Allowed Value Of Contract And Shall Be Taken From All All Bidders Vendors For Contract Value Above Rs. 25 Lakh Subject To The Applicable Exemptions. For Details Please Refer 10.0 Part A Of Southern Railway Tender Conditions. In Case Of Submission Of Security Deposit In The Form Of Bank Guarantee, Please Refer Annexure 5 Of Southern Railway Tender Conditions For The Proforma For Bg. 8 As Per Para 0501 Of Irs Conditions Of Contract - Normal Applicable To Yes Yes Not Allowed Security Deposit Should Remain Valid For A All Bidders Minimum Period Of 60 Days Beyond The Date Of Completion Of All The Contractual Obligations Of The Supplier, Including Warranty Obligations I.E. 2 Years From The Date Of Installation, Commissioning And Testing Of The Stores. Page 7 Of 19 Run Date/Time: 06/06/2025 12:02:48Pgt Div/Southern Rly Tender Document Tender No 91255470 Closing Date/Time 01/07/2025 14:30 9 Earnest Money Deposit (Emd) Shall Be Normal Applicable To Yes Yes Allowed Deposited By All Vendors For Tenders With All Bidders (Optional) Estimated Value Above Rs.25 Lakhs Subject To The Applicable Exemptions. The Para 2.1 Of The Part A Of Sr Tender Conditions With Regard To Emd Exemption Is Superseded As Below And The Conditions Mentioned Here Below Will Prevail Over That Of In Para 2.1 Of The Part A Of Sr Tender Conditions Attached To This Tender Document: Emd Amount Shall Be Mentioned In All Tenders Irrespective Of The Nature Of Tender As Per The Emd Amount Mentioned In Clause 2.3 Of Part A Of Sr Tender Conditions Or As Decided By The Purchaser Under The Policy. There Shall Be No Exemption From Submission Of Emd For Any Tender Or By Any Tenderer Subject To Provisions Under Clause 10.4.3 Of Part A Of Sr Tender Conditions Except Following : (I) Emd Shall Normally Not Be Called Against Tenders With Estimated Value Up To Rs.25 Lakhs (Including Single Tenders, Global Limited Tenders) Except Cases Where Competent Authority Incorporates The Condition To Call For Emd. Ii) Public Sector Undertakings (Psus) A. Psus Owned By Ministry Of Railways And B. Psus For The Group Of Items That Are Manufactured By Them. Iii) Mses Registered Under Udyam Registration Shall Be Eligible For Exemption From Payment Of Emd Irrespective Of Relevance Of Product Category For Which They Are Registered With Udyam. However, Traders/Distributors/Sole Agent/Works Contract Are Not Exempted From Payment Of Emd As They Are Excluded From The Purview Of The Policy. Iv) Other Railways, Indian Ordinance Factories And Govt. Departments. V) In Exceptional Cases, Where Emd Exemption Is Specifically Incorporated In Tender Conditions. Vi) Vendors Registered With Railways For The Trade Group/Trade Groups Of The Tendered Item . Vii) Regular And Development Vendors Appearing On The Approved Vendor Lists Of Rdso/Pus/Core Etc., For Those Speciï¬C Item For Which They Are On The Approved List, Subject To Approval Status Being Valid On The Date Of Tender Closing. Viii) Vendors Registered With Railways For Supply Of Medicine, Medical Equipments And Consumables Shall Be Exempted From Submission Of Emd For These Items. Ix) In Tenders Issued Against Pac, Oem In Whose Favour Pac Has Been Issued Shall Be Exempted From Submitting Emd. Kvic And Acash Shall Be Exempted From Emd For Items Supplied By Them. In Case Of Submission Of Earnest Money Deposit In The Form Of Bank Guarantee, Please Refer To Sr Tender Conditions. Page 8 Of 19 Run Date/Time: 06/06/2025 12:02:48Pgt Div/Southern Rly Tender Document Tender No 91255470 Closing Date/Time 01/07/2025 14:30 10 In Terms Of Railway Boards Letter No. Normal Applicable To Yes Yes Not Allowed 2015/Rs(G)/779/5(Vol.Iii) Dated: 22.06.2020 All Bidders And In Keeping With The Public Procurement (Preference To Make In India) Order, 2017 As Amended, It Has Been Found That There Is Suï¬Ƒcient Local Capacity And Competition In Supply Of The Tendered Item Of Required Quality And Therefore Public Procurement Of This Tendered Item Is Restricted To Class I Local Suppliers Only (Class-I Local Supplier Means A Supplier Or Service Provider, Whose Goods, Services Or Works OffEred For Procurement, Has Local Content Equal To Or More Than 50%). The Class I Local Supplier At The Time Of Bidding Shall Indicate Percentage Of Local Content. The Vendors Who Do Not Qualify To Be Class I Local Suppliers Should Not Quote In The Tender As Their OffErs Shall Not Be Considered For Any Ordering. In Case Any Vendor Who Does Not Qualify To Be A Class I Local Supplier For The Tendered Item Participates In The Tender It Does So At Its Own Risk And Cost And Railways Shall Not Be Liable For Any Loss Or Damage Caused To The Vendor. 11 Failure Consequences: In Case The ϬRm Fails To Normal Applicable To Yes Yes Not Allowed Execute The Contract Within The Original Delivery All Bidders Period, The Purchaser Will Be Entitled To Impose Liquidated Damages For Extension Of Delivery Period. For Any Reason, If The Supplier Fails To Supply Goods As Per The Conditions Of Contract, As Amended From Time To Time, Purchaser Shall Have The Right To Levy Damages From The Supplier For Failing To Comply With The Contractual Conditions, Not By The Way Of Penalty, An Amount Equal To 10% Of The Defaulted Order Amount. These Damages Shall B E Treated As Recoveries Outstanding Against The Vendor And Dealt With Accordingly. 12 All Taxes, Freight, Packing, Forwarding & Other Normal Applicable To Yes Yes Not Allowed Charges Should Be Quoted In Numeric Only @ All Bidders Financial Tabulation. 13 Please Enter The Percentage Of Local Content In Normal Applicable To No Yes Allowed The Material Being OffEred. Please Enter 0 For All Bidders (Optional) Fully Imported Items, And 100 For Fully Indigenous Items. The Deï¬Nition And Calculation Of Local Content Shall Be In Accordance With The Make In India Policy As Incorporated In The Tender Conditions. General Instructions S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 The Advertised Value Of The Current Tender Is Rs. Normal Applicable To No No Not Allowed 4,58,72,619/- All Bidders 2 For Any Queries Against The Tender Please Normal Applicable To No No Not Allowed Contact Sr.Dmm/Pgt/Sr At 97467 63770. All Bidders 3 Any Technical Clariï¬Cation Regarding Normal Applicable To No No Not Allowed Drawing/Speciï¬Cation Can Be Obtained From The All Bidders Oï¬Ƒce Of The Dee/G/Pgt. Drawing (S) / Specification (S) Can Also Be Obtained From The Above Oï¬Ƒce After Payment Requisite Cost Page 9 Of 19 Run Date/Time: 06/06/2025 12:02:48Pgt Div/Southern Rly Tender Document Tender No 91255470 Closing Date/Time 01/07/2025 14:30 4 1) Bidders Are Instructed Not To Indulge In Any Normal Applicable To No No Not Allowed Anti-Competitive Practices. As Per The Provisions All Bidders Of Competition Act,2002, Railways Can Make A Reference To The Competition Commission Of India For Making An Enquiry In Case Of Suspected Anti-Competitive Behavior By The Bidders. 2) Collusive Bidding, Bid Rotation, Bid Suppression, Complementary Bidding, Market Allocation And Sub-Contracting Arrangements Fall Under The Purview Of Bid Rigging Which Would Cause Appreciable Adverse EffEct On Competition. 3) Competition Commission Of India Can Impose Heavy Penalties Such As: Penalty Upto 10% Of The Average Turnover For The Last Three Preceding ϬNancial Years Upon Each Of Such Enterprises Which Are Parties To Bid-Rigging And Can Even Order The Parties To Cease And Desist. 5 (1) As Per Section 171 Of Gst Act 2017, As A Normal Applicable To No No Not Allowed Remedy Against Anti-Proï¬Teering, Input Tax All Bidders Credit Beneï¬T If Any Accrued Should Be Passed On To The Purchaser As Reduction In Basic Price, Or Else The Following Certiï¬Cate Should Accompany The Bill: It Is Certiï¬Ed That No Input Tax Credit Beneï¬T Has Accrued On Materials Invoiced/Billed For, That Can Be Passed On To Purchaser. B) Firm Should Submit The Invoice/Bill Clearly Indicating The Appropriate Hsn And Applicable Gst Rate Thereon Duly Supported With Documentary Evidence. C) Firm Should Also Give A Declaration That Any Additional Input Tax Credit Beneï¬T, If Become Available To Supplier, The Same Shall Be Passed On To The Purchaser Without Any Undue Delay (2) All The Bidders/ Tenderers Should Ensure That They Are Gst Compliant And Their Quoted Tax Structure / Rates Are As Per Gst Law. In Case The Successful Tenderer Is Not Liable To Be Registered Under Cgst/Gst/Utgst/ Sgst Act, Railway Shall Deduct The Applicable Gst From His / Their Bills Under Reverse Charge Machanisam (Rcm) And Deposit The Same To The Concerned Tax Authority. (3) - 1.Railway Is Not Bound To Accept / Cancel The Lowest Or Any Tender Or To Assign Any Reason For Doing So And Railway Reserves The Right To Accept / Cancel Any Tender In Respect Of The Whole Or Any Portion Of The Items Specified In The Schedule Annexed (Or Tender Schedule) And The Contractor Shall Be Required To Supply The Same At The Rate Quoted. 2.Vendors May Please Note That Giving Intimation Regarding The Tender In Open Tender Cases Or Giving Limited Tender Enquiry Does Not Guarantee The Suitability Of Offer For Placement Of Purchase Order. Railway Reserve The Right To Place Purchase Order Subject To Fulfillment Of Technical / Commercial Eligibility Conditions/ Tender Conditions. Other Conditions S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading Page 10 Of 19 Run Date/Time: 06/06/2025 12:02:48Pgt Div/Southern Rly Tender Document Tender No 91255470 Closing Date/Time 01/07/2025 14:30 1 (1) Inspection By Designated Tpi Agency Against, Normal Applicable To No No Not Allowed Valid Prototype Inspection Certiï¬Cate Approved All Bidders By Rdso Vide R.B.Letter No. 2019/Elect(G)/150/3/Escal.Dt.05.11.2020 To Be Produced. (Tenderer To Enclose Prototype Test Certificate) (2) In Case Of Any Deviation To Inspection, Should Be Clearly Indicated In The Offer. (3) Firm Should Provide Complete Work Address Where Inspection Is To Be Carried Out. (4) Inspection Agency Mentioned Any Where In The Tender/Speciï¬Cation Document Should Be Read As Above. 2 The Firm Shall Submit Invoice/Bill Clearly Normal Applicable To Yes Yes Not Allowed Indicating The Appropriate Hsn Code And All Bidders Applicable Gst Rate Thereon Duly Supported With Documentary Evidence. S.Rly. Kerala Gstn No. 32Aaagm0289c1zs S.Rly Tamilnadu Gstn No.33Aaagm0289c1zq 3 Tenderers Shall Conï¬Rm The Following Normal Applicable To Yes Yes Allowed Declaration Failing Which The OffEr Will Be All Bidders (Optional) Ignored. I Have Read The Clause Regarding Restrictions On Procurement From A Bidder Of A Country Which Shares A Land Border With India. I Certify That This Bidder Is Not From Such A Country Or, If From Such A Country, Has Been Registered With The Competent Authority. I Hereby Certify That This Bidder Fulï¬Lls All Requirements In This Regard And Is Eligible To Be Considered. Where Applicable, Evidence Of Valid Registration By The Competent Authority Shall Be Attached. 4 All Other Terms And Conditions Are As Per Normal Applicable To Yes Yes Not Allowed Attached Documents. All Bidders Special Conditions S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 One Of The Essential Principles Of Purchasing Normal Applicable To No No Not Allowed Function Is Selection Of Right Source For Supply. All Bidders This Aspect Has Been Emphasized By Railway Board Through Various Circulars In The Past Rb Lr No. 2022/Rs(G)777/1(E 3382862) New Delhi Dated 07.07.2022 With Sub: Acceptance Of Tender, Consideration Of Performance Of Vendors. Railway Board Letter Dated 11.02.2016 Interalia Stipulates Due Consideration Of Dis- Satisfactory Past Performance Of Vendors While Deciding Tender To Ensure Timely Supply Of Material In Required Quantity To Meet The Needs Of Operation, Maintenance, Safety, Etc. Of The Railways. With Complete Digitization Of Supply Chain, Suï¬Ƒcient Data Is Available On Ireps/Imms ReflEcting Various Aspects Of Performance Of Suppliers For Individual Contract, Supplier And Item. Warranty Failures And Response Of Vendors To Such Failures Is One Of The Important Parameters Of Performance Of A Vendor. Suitable Means May Be Adopted To Capture Warranty Performance Of The Vendors. It Is Again Emphasized That Performance Of Vendors, Including Warranty Failures And Response, Would Invariably Be Considered While Deciding The Tenders. 2 Tenderers Are Advised To Check Our Website Normal Applicable To No No Not Allowed Before/After Submitting Their OffEr Whether Any All Bidders Corrigendum To The Tender Has Been Issued Or Not. Page 11 Of 19 Run Date/Time: 06/06/2025 12:02:48Pgt Div/Southern Rly Tender Document Tender No 91255470 Closing Date/Time 01/07/2025 14:30 3 Past Performance By Way Of Complied Pos Or Normal Applicable To No No Not Allowed R/Notes Or Inspection Certiï¬Cates From Railways All Bidders / Production Units Or Other Govt. Departments If Any To Be Uploaded With E-Bid. 4 The Supplier Must Be Responsible To Replace The Normal Applicable To No No Not Allowed Item If It Gets Damaged During The Time Of All Bidders Delivery. 5 (1) Delivery By Road On Door Delivery Basis. Normal Applicable To No No Not Allowed All Bidders (2) Delivery Charges Including Unloading Charges At Destination Are In The Scope Of The Supplier. (3) Supply And Installation Is To Be Done At Kannur (3 Numbers) And Kasargod (4 Numbers) Railway Stations. 6 Contact Details: Normal Applicable To No No Not Allowed Any Technical Clariï¬Cation Regarding All Bidders Drawing/Specification Can Be Obtained (1) Office Of The Senior Section Engineer - Electrical (Works)--- Southern Railway--- Palakkad-Kerala--678002 Contract Number: 7012463289 (2) Divisional Electrical Engineer (Dee/G) 9746763301 7 1) Installation, Testing And Commissioning Of Normal Applicable To No No Not Allowed Escalators At Site. All Bidders 2) All Other Terms And Conditions Are As Per Attached Documents. 3) Firm To Submit Oem Certiï¬Cate Along With Supply. 4) Firm Has To Quote Separately For Comprehensive Amc For 5 Years As Per The Tender Condition. Page 12 Of 19 Run Date/Time: 06/06/2025 12:02:48Pgt Div/Southern Rly Tender Document Tender No 91255470 Closing Date/Time 01/07/2025 14:30 8 1) Camc : Bidders To Note That This Is A Normal Applicable To No No Not Allowed Composite Tender For Procurement And Post All Bidders Warranty Comprehensive Annual Maintenance Contract I.E. Camc For 05 Years Beyond 2 Years Comprehensive Warranty Period. Bidders Are Required To Quote Charges For Camc For Post Comprehensive Warranty Period Of Camc For 05 Years. 2) Evaluation And Ranking Of The Offers Shall Be Arrived Based On Cost Of Equipment Plus Camc Charges For 5 Years [Adjusted To Net Present Value] After Comprehensive Warranty Period Of 2 Years As Per Specification For Each Group Of The Tendered Item. 3) Firm Should Quote Actual Rate Of Camc In Their OffEr While Quoting The Bid. The Npv Will Be Worked Out At A Discounting Rate Of 10%. The System Will Calculate Net Present Value Of Camc Of OffEr Automatically Based On Which Ranking Will Be Done. Calculation Of Npv Is Only For The Purpose Of ϬNancial Evaluation Of OffEr And Determining The Inter-Se Ranking. Payment Of Camc Charges Will, However, Be As Per Actual Annual Camc Charges Accepted In The Tender. No Advance Payment For Camc Charges Shall Be Made. A) Firm To Quote Separately For Each Camc Year Ie: Year 1 Tab (For 3Rd Year), Year 2 Tab (For 4Th Year), Year 3 Tab (For 5Th Year),Year 4Th Tab (For 6Th Year), Year 5Th Tab (For 7Th Year). 4) Railway Reserves The Right Through Consignee Oï¬Ƒcer Whether To Enter Into Camc Contract Or Not As Per The Accepted Rate Schedules. Firm Is Contractually Bound To Provide Camc Services If Consignee Enters Into Camc Contract For 5 Years. 5) Consignee Reserves The Right To Cancel The Camc Contract By Forfeiting The Camc Bg Or By Recovering Applicable Penalty Charges In Case Of Non-Performance/Default In Fulï¬Lling Camc Obligations As Per Terms & Conditions Of Camc, By Serving A 01 Month Notice. Page 13 Of 19 Run Date/Time: 06/06/2025 12:02:48Pgt Div/Southern Rly Tender Document Tender No 91255470 Closing Date/Time 01/07/2025 14:30 9 Penalty For Delay In Commissioning: The Normal Applicable To No No Not Allowed Contractor Or His Agents Shall Commission The All Bidders Machine Within The Stipulated Time As Shown In The Contract. This Time Frame Will Be Applicable From The Consignee In Respect Of Readiness And Installation Of The Machine In Cases Where The Machine Is To Be Installed By The Consignee. The Time Schedule Includes The Time For Installation In Cases Where Installation Is Also To Be Undertaken By The Supplier. The Time Allowed For Commissioning Of Machine By The Contractor Or His Agent Shall Be Deemed To Be The Essence Of The Contract. In Case Of Delay In Commissioning Of The Machine On The Part Of Contractor, The Purchaser Shall Be Entitled To Recover And The Contractor Shall Be Liable To Pay Pre Estimated Liquidated Damage At The Rate Of 2% Of The Total Contract Value Of Machine Not Commissioned For Each And Every Month Or Part Thereof For Which Commissioning Is Delayed. Provided Always That The Entire Amount Of Liquidated Damages To Be Paid Under The Provision Of This Clause Shall Not Exceed 10% Of The Total Contract Value. After Expiry Of 3 Months Period From The Date Of Default I.E. From The Date Of Commissioning Provided In The Contract, Purchaser Will Be At Liberty To Invoke The Pg Bond Submitted Or Recover From The Supplier. Continuance Of Commissioning Work After Expiry Of Stipulated Time Will Also Not Absolve The Contractor From The Liquidated Damages As Stated Above. The Decision Of The Railways, Whether The Delay In Commissioning Has Taken Place On Account Of Reasons Attributed To The Contractor Shall Be Final. 10 In Case Of Delay In Approval Of Gad On Railway Normal Applicable To No No Not Allowed Account, Extension Of Dp As Reï¬X Shall Be Dealt All Bidders With Accordingly. The Design, Manufacture, Supply, Installation, Testing And Commissioning To Be Completed Within The Given Completion Period On Award Of Contract. In Case Supplies Are Required To Be Deferred By Railways Due To Site Conditions Or Any Other Reasons, The Intimation Shall Be Given To All Concerned 15 Days Before The Due Delivery Date To Re-ϬX Dp Accordingly. 11 Camc Charges: The Camc For The Elevator Will Normal Applicable To No No Not Allowed Be Comprehensive And Shall Be Inclusive Of All All Bidders Spares, Material And Labour Cost For Schedules/Unscheduled Day-To-Day Maintenance. Two Months Before Completion Of Warranty Period, A Separate Camc Agreement Shall Be Entered Into With Sr.Dee/Pgt Of The Division As Per Accepted Rate In The Bid. Payment Of Camc Charges Will Be Made On Quarterly Basis, After EffEcting Deduction Towards Penal Charges, Etc On Certiï¬Cation By User Department At The Level Of Gazetted Oï¬Ƒcer. The Performance Guarantee @ 5% Of Contract Value Which Was Submitted Towards Warranty Obligations Is To Be Extended For Further 5 Years Of Camc Period With Validity Beyond 6 Months After Expiry Of Camc Period, In Case If Consignee Enters Into Camc. The Same Will Be Released After Completion Of Camc Period. 12 Evaluation Criteria Is Group Wise And Bidders Normal Applicable To No No Not Allowed Should Quote Rate For Both The Tendered Items In All Bidders Each Group I.E. Cost Of Escalator And Camc Or Else Offer Will Be Rejected. 13 Comprehensive Annual Maintenance Normal Applicable To No No Not Allowed Contract (Camc) For Heavy Duty All Bidders Escalators For 5 Years (For Each Year Separetely) After Expiry Of Warranty Period As Per Enclosed Instructions And Rdso Speciï¬Cation No. Rdso/Pe/Spec/Tl/0095(Rev-3) - 2019. Page 14 Of 19 Run Date/Time: 06/06/2025 12:02:48Pgt Div/Southern Rly Tender Document Tender No 91255470 Closing Date/Time 01/07/2025 14:30 14 1) Warranty : 24 Month From The Date Of Normal Applicable To No No Not Allowed Commissioning (Or ) 30 Months From The All Bidders Date Of Supply As Per Rdso Specification And Inclusion. 2) Warranty/Camc Penalty Conditions Will Be As Per Letter No. E.61.G Dt. 11- 10-2023. 15 Schedule Of Requirements Above Is Only Normal Applicable To No No Not Allowed Indicative. The Actual Consignees And The All Bidders Quantity To Be Delivered Are Exactly As Mentioned: Kannur - 3 Nos, Kasargod - 4 Nos). The Delivery Schedule Is Tentative And ϬNal Date Will Be Given At The Time Of Release Of Contract. 16 Tenderers May Note That Their OffEred Delivery Normal Applicable To No No Not Allowed Schedule Should Clearly Indicate The Starting All Bidders Time, Quarterly Rate Of Supply And Finishing Time. For OffErs With Vague Delivery Schedule Like -02 To 12 Months- Or Like -06 To 10 Months-, Dp Shall Be Given As Per The Requirement Best Suited To This Office Within The Quoted Range 17 Monthly Progress Report: The Contractor Shall Normal Applicable To No No Not Allowed Furnish During The ϬRst Week Of Every Calendar All Bidders Month, A Progress Showing Progress Of ϬNalization Of Designs And Drawings, Materials Received At Site And The Work Carried Out During The Preceding Months. As Far As Possible The Presentation Shall Be Neat And In Tabulation Form Accompanied By Coloured Diagram Wherever Applicable. 18 Loading And Unloading Of Heavy Materials: The Normal Applicable To No No Not Allowed Contractor Shall Make His Own Arrangements For All Bidders Loading Or Unloading Of All Materials At His Depot Or At Work Sites 19 Pre-Decided Quantity Splitting Clause Is Normal Applicable To No No Not Allowed Applicable As Per The Para 5.0 Of Part B Of Sr All Bidders Tender Conditions Attached To This Tender Document, In Order To Ensure Timely Availability Of Material Through Placement Of Orders On Multiple Sources. 20 Delivery Locations Indicated In Tender Document Normal Applicable To No No Not Allowed Are ϬNal And No Deviation To Be Quoted By Any All Bidders Tenderer. However, In Case Of Any Change By Railway Administration In Delivery Location In Terms Of Indicated Platform Number, Rly Stn Or Location, It Should Be Accommodated By Tenderer. 21 Purchaser Reserves The Right To Change The Normal Applicable To No No Not Allowed Inspection Agency Or To Accept The Material All Bidders Based On Wtc At Post Contract Stage, In Case Of Extreme Emergencies/Urgencies As Tendered Stores Are Related To Passenger Amenity Items Under Station Development. 22 The Tenderers Shall Submit A Copy Of Certiï¬Cate Normal Applicable To No No Not Allowed Stating That All Their Statements/Documents All Bidders Submitted Along With Bid Are True And Factual. Standard Format Of Certiï¬Cate To Be Submitted Along With Bid Are True And Factual. Standard Format Of Certiï¬Cate To Be Submitted By The Bidder Is Enclosed As Annexure-I. Non- Submission Of Above Certiï¬Cate By The Bidder Shall Result In Summary Rejection Of His/Their Bid. It Shall Be Mandatorily Incumbent Upon The Tenderer To Identify, State And Submit The Supporting Documents Duly Self- Attested/Digitally Signed By Which They/He Is Qualifying The Qualifying Criteria Mentioned In The Tender Document. It Will Not Be Obligatory On The Part Of Tender Committee/Accepting Authority To Scrutinize Beyond The Submitted Document Of Tenderer As Far As His Qualiï¬Cation For The Tender Is Concerned. Thus Submission Of Annexure-I By Tenderer Is Mandatory. Page 15 Of 19 Run Date/Time: 06/06/2025 12:02:48Pgt Div/Southern Rly Tender Document Tender No 91255470 Closing Date/Time 01/07/2025 14:30 23 The Purchaser Reserves The Right To Discharge Normal Applicable To No No Not Allowed The Tender In Case Cartel Is Suspected Or The All Bidders Tender/Contract Is Not Found To Be Advantageous/Reasonable For Railways 24 Tenderers May Note That Their OffEred Delivery Normal Applicable To No No Not Allowed Schedule Should Clearly Indicate The Starting All Bidders Time, Quarterly Rate Of Supply And Finishing Time. For OffErs With Vague Delivery Schedule Like -02 To 12 Months- Or Like -06 To 10 Months-, Delivery Period Shall Be Given As Per The Requirement Best Suited To This Oï¬Ƒce Within The Quoted Range. 25 The Standard Vertical Height Of Escalator Is 6 Normal Applicable To No No Not Allowed Meters. The Supplier Shall Be Given Plus Or All Bidders Minus 0.6 Percentage Of Quoted Rate With Variation Of Vertical Heights Plus Or Minus 0.15 Meters I.E. If The Height Becomes 6.15 Meters Then The Amount Paid To Bidder Will Be 1.006 Times Quoted Rate And If Height Becomes 5.85 Meters Then The Amount Paid Will Be 0.994 Times Of Quoted Rate. Technical-Compliances S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading Page 16 Of 19 Run Date/Time: 06/06/2025 12:02:48Pgt Div/Southern Rly Tender Document Tender No 91255470 Closing Date/Time 01/07/2025 14:30 1 1) OffEred Model, Product Brochure/Literature To Normal Applicable To Yes Yes Allowed Be Uploaded For Evaluation. All Bidders (Optional) 2) In Case Of Any Deviation To Speciï¬Cation Like In Terms Of Dimension, Capacity, Size And Etc It Should Be Clearly Indicated In The Offer. 3) Railway Reserves The Right Either To Consider Or Not To Consider OffEred Deviations Based On End User Requirement. 4) Machine Will Be Under Comprehensive Warranty During The Warranty Period. Firm Should Render Warranty Services Immediately. 5) Firm Should Submit General Arrangement Drawing And Etc As Per Speciï¬Cation For The Approval Of Sr.Dee/G/Pgt Before Supply And Commencement Of Work At Site. 6) The ϬRm Should Have Electrical Contractor License & Electrical Supervisor License In Their Own Name Or In The Name Of Their Representative Involved In Execution Of The Work. Necessary Documents To Be Uploaded Along With Offer. 7) The Supplier Should Have Service Centre/Service Engineer At Kerala For Which Necessary Proof Of Documents To Be Submitted Along With The Offer. 8) Note: The Attention Of All Personnel Engaged On Escalators Maintenance Services Is Drawn To The Need For The Proper Observance Of All Safety Rules,Regulations And Statutory Requirements. It Is Essential That All Apparatus Is Rendered And Kept Safe, During Servicing Operations. Protective Clothing And Other Safeguards Shall Be Worn Or Used. All Defects In Tools, Steps,Ladders And Other Items Are To Be Reported Immediately And The Equipment Not To Be Used Until The Fault Is Rectiï¬Ed. The Lubricants Used Shall Be Of The Brands And Grades Recommended By The Manufacturer Or Their Approved Equivalents. Ensure Adequate Lubrication, But Avoid Excess. Spillage Shall Be Wiped Off. Oily Rags Or Waste Shall Be Removed. 9 ) Provision For Sending Sms Messages Immediately To Minimum Ten Pre-Speciï¬Ed Phone Numbers In Case Of Escalators Failures For Timely Attention And Rescue And For Identiï¬Ed Unusual Occurrences Shal Be Available In The Controler. Provision Of Sim And Payment Of Data Charges Should Be Borne By The Supplier Till Escalator Is Under Warranty And Beyond. Firm Should Provide Concerned Railway Free Of Cost Of Monitoring Facility. 10) The Manufacturer Shall Furnish An Undertaking Along With Their OffEr Regarding Availability Of Spares For The Entire Expected Life Of The Escalator I.E., 15 To 20 Years. 1 1 ) The Complete Escalator Installation Including Its Components, Safety Devices, Various Types Of Controls Etc., Testing, Inspection, Operation & Maintenance Shall Conform To Relevant Codes, Standards, Code Of Practices, Guidelines, Safety Rules, Inspection Manual (S), Rules Issued By Bureau Of Indian Standards As Amended Up To The Last Date Of Receipt Of Tenders. Quality Standards Shall Conform To Latest Is/Iso-9001:2015. Page 17 Of 19 Run Date/Time: 06/06/2025 12:02:48Pgt Div/Southern Rly Tender Document Tender No 91255470 Closing Date/Time 01/07/2025 14:30 2 Supplier Should Submit Detailed Drawing ( Gad) Normal Applicable To Yes Yes Not Allowed Of The Escalator After Visiting The Site And All Bidders Considering The Actual Site Conditions In Consultation With Concerned Sr.Section Engineer / Electrical. 2. Supplier Should Send His Representative To The Site Frequently In Consultation With The Consignee To Supervise The Civil Work, Prior To And During The Civil And Electrical Works To Give Necessary Instruction At Site. 3. The Materials Shall Be Inspected By Tpi And Dispatched To The Site Duly After Completion Of Civil Works. Necessary Cost For Tpi Inspection Should Be Borne By The ϬRm. 4. Supplier Should Make His Own Arrangement To Stock And Safe Guard The Material At Site. 5. Necessary Test Report To Get The Eig Approval Should Be Submitted By The Supplier After Completing The Installation. 6. Necessary Training To Railway Staff At Station To Be Given By The ϬRm Periodically For Minor Trouble Shooting In Case Of Failures. 3 Tenderers Should Agree To The Normal Applicable To Yes Yes Not Allowed Guarantee/Warranty As Per Speciï¬Cation And In All Bidders Case Speciï¬Cation Does Not Contain Gc/Wc Then Gc/Wc As Per Irs Conditions Of Contract Will Apply. 6. Bidders Shall Confirm And Certify On The Behalf Of The Tenderer Including Its Constituents As Under: S.No. Description 1 I/We The Tenderer (S) Am/Are Signing This Document After Carefully Reading The Contents. 2 I/We The Tenderer(S) Also Accept All The Conditions Of The Tender And Have Signed All The Pages In Confirmation Thereof. I/We Hereby Declare That I/We Have Downloaded The Tender Documents From Indian Railway Website Www.Ireps.Gov.In . I/We Have Verified The Content Of The Document From The Website And There Is No Addition, No Deletion Or No Alteration To The Content Of The 3 Tender Document. In Case Of Any Discrepancy Noticed At Any Stage I.E. Evaluation Of Tenders, Execution Of Contract Or Payment, The Master Copy Available With The Railway Administration Shall Be Final And Binding Upon Me/Us. I/We Declare And Certify That I/We Have Not Made Any Misleading Or False Representation In The Forms, Statements And Attachments 4 In Proof Of The Qualification Requirements. I/We Also Understand That My/Our Offer Will Be Evaluated Based On The Documents/Credentials Submitted Along With The Offer And 5 Same Shall Be Binding Upon Me/Us. I/We Declare That The Information And Documents Submitted Along With The Tender By Me/Us Are Correct And I/We Are Fully 6 Responsible For The Correctness Of The Information And Documents, Submitted By Us. I/We Certify That I/We The Tenderer(S) Is/Are Not Blacklisted Or Debarred By Railways Or Any Other Ministry / Department Of Govt. Of 7 India From Participation In Tender On The Date Of Submission Of Bids, Either In Individual Capacity Or As A Huf/ Member Of The Partnership Firm/Llp/Jv/Society/Trust. I/We Understand That If The Contents Of The Certificate Submitted By Us Are Found To Be Forged/False At Any Time During Process For Evaluation Of Tenders, It Shall Lead To Forfeiture Of The Emd And May Also Lead To Any Other Action Provided In The Contract Including 8 Banning Of Business For A Period Of Upto Two Year. Further, I/We And All My/Our Constituents Understand That My/Our Offer Shall Be Summarily Rejected. I/We Also Understand That If The Contents Of The Certificate Submitted By Us Are Found To Be False/Forged At Any Time After The Award 9 Of The Contract, It Will Lead To Termination Of The Contract, Along With Forfeiture Of Security Deposit And May Also Lead To Any Other Action Provided In The Contract Including Banning Of Business For A Period Of Upto Two Year. I/We Have Read The Clause Regarding Restriction On Procurement From A Bidder Of A Country Which Shares A Land Border With India And Certify That I Am/We Are Not From Such A Country Or, If From Such A Country, Have Been Registered With The Competent 10 Authority. I/We Hereby Certify That I/We Fulfil All The Requirements In This Regard And Am/Are Eligible To Be Considered (Evidence Of Valid Registration By The Competent Authority Is Enclosed) 7. Documents Attached With Tender S.No. Document Name Document Description 1 5393259.Pdf Payment Conditions 2 5414881.Pdf Annexure I Certification By Tenderer 3 5393272.Pdf Rdso Specification Page 14-28 4 5393276.Pdf Rdso Specification Page 29-44 5 5393278.Pdf Rdso Specification Page 45-59 6 5393280.Pdf Rdso Specification Page 60-70 7 5393282.Pdf Rdso Specification Page 71-74 8 5393285.Pdf Annexure For Camc 9 5393296.Pdf Proto Type Inspection 10 5393298.Pdf Annexure For Payments Page 18 Of 19 Run Date/Time: 06/06/2025 12:02:48Pgt Div/Southern Rly Tender Document Tender No 91255470 Closing Date/Time 01/07/2025 14:30 11 5423357.Pdf Penalty Conditions 12 5423359.Pdf Penalty Condition 1 13 5393307.Pdf Annexure I Of Item No. 002 Pl No. 479023280070 14 5393316.Pdf Annexure I Of Item No. 005 Pl.No.479023280100 15 5393271.Pdf Rdso Specification Page 1-13 The Tenderers In Their Bid Shall Indicate The Details Of Their Gst Jurisdictional Assessing Officers (Designation, Address & Email Id). In Case Of A Contract Award, A Copy Of Purchase Order Shall Be Immediately Forwarded By Purchaser To The Gst Jurisdictional Assessing Officer Mentioned In Tenderers Bid This Tender Complies With Public Procurement Policy (Make In India) Order 2017, Dated 15/06/2017, Issued By Department Of Industrial Promotion And Policy, Ministry Of Commerce, Circulated Vide Railway Board Letter No. 2015/Rs(G)/779/5 Dated 03/08/2017 And 27/12/2017 And Amendments/ Revisions Thereof. As A Tender Inviting Authority, The Undersigned Has Ensured That The Issue Of This Tender Does Not Violate Provisions Of Gfr Regarding Procurement Through Gem. Digitally Signed By Cmm-Adrm-Pgt ( S Jayakrishnan ) , Design, Manufacture, Supply At Site, Installation ,Testing And Commissioning Of Heavy Duty Passe Nger Escalators Along With Energy Meter At Kannur Railway Station In Pf No. 1 & 2/3 And Shall Be Supplied In Acc Ordance With The Requirements Of The Site, As Furnished In The Annexure-I. The Escalator Shall Be As Per The Rds O Specification No.Rdso/Pe/Spec/Tl/0095 (Rev 3) -2019. Warranty: 24 Months From The Date Of Commissioning . During Warranty Period, All Scheduled Maintenance (As Per Rdso Specification No. Rdso/Pe/Spec/Tl/0095 (Re V 3) -2019, Annexure-6 Check List ) Must Be Performed For Which No Extra Payment Will Be Made. Note: The Fir M Shall Provide A Separate Quote For A Comprehensive Annual Maintenance Contract For Five Years, As Per The Ca Mc Conditions Enclosed. [ Warranty Period: 30 Months After The Date Of Delivery ] ] , Post Warranty Comprehensive Annual Maintenance Charges (After 2 Year Free Warr Anty Period) - Firm To Quote Separately For Each Camc Year Ie: Year 1 Tab (For 3Rd Year), Year 2 Ta B (For 4Th Year), Year 3 Tab (For 5Th Year),Year 4Th Tab (For 6Th Year), Year 5Th Tab(For 7Th Year). Fir M Should Quote The Actual Rate Of The Camc In The Bid, Discounted Rate As Per Npv Will Be Generated B Y The Ireps System For Ranking Purpose. [ Warranty Period: 2 Years, Amc Period: 5 Years, Rate Of Discoun Ting: 10 % ] ] At (Location) Sse/E/W/Pgt, Sr Kerala 00 Numbers
Contract Date : 22 Sep, 2025   |   Contract Value : 4.69 Crore
BRR : 3135521 Supply Of Office And Supply Of Office And Laboratory Equipment , Central Instrumental Cell , Dehumidifier (Environmental Controller) : With Refrigeration System. Minimum Humidity: 30% Rh +/- 3% Rh. Control Microprocessor Based Humidity Controller With Direct Rh% Sensor. Relative Humidity Range: 30% Rh To 65% Rh.Vertical Model With 1.5 Ton Capacity , Elemental Analyser For Automatic Determination Of C-H-N-S-O: Fully Automated Pc Controlled Elemental For Solids, Liquid And Semi Solid Samples. Operating Modes For Measurement Of Chns, Chn, Cns, S, And O-Tcd Sample Weight Range: 0.02 To 1000 Mg For Chns Mode Detection Range: 0 To 100% For All Elements (C, H, N, S, 0) With The Capability Of Measuring At Least 10 Mg Absolute Carbon In Chns Mode And More Than 40 Mg In Cn Mode. Limit Of Detection: 50 Ppm Or Less Standard Deviation: 0.1 % Of Absolute. Should Comply Astm D1552, Astm D5291, Din En Iso 16948 Furnace System Should Have Two Furnace System For Chns Mode, Separate Combustion/ Reduction With Independent Temperature Control For Each Furnace. It Should Be Possible To Set Difference Temperature For Combustion And Reduction.Combustion And Reduction Furnace Temperature Should Be 1200 Deg C Or More Furnace Working On Low Voltage For Safety And Long Life With 10 Years Warranty. Should Have Possibility To Use Ceramic/Quartz Ash Finger To Handle High Halogen Or Fluorine Contents Sample. Separation System Advanced Chromatographic Separation Of Gases Using Temperature Programmed Desorption Column.Complete Instrument Control Over Elution Process With Provision Of Auto Zero Of Baseline After Each Element.Fully Separation Of All Analysts And There Shouldbe No Peak Tailing Or Peak Overlapbaseline Separation Of C From N Peak Signal With A Concentration Ratio Of 12000: 1 Or Better Detector System Oxygen Intrusion Free Thermistor Technology Based Temperature Stabilized Tcd Detector For Measurement Of C-H-N-S-O 10 Years Warranty On Tcd Detector. Auto Sampler System Electromechanical Auto Sampler System With 100 Positions Or More In Single Tray. It Should Be Possible To Remove The Auto Sampler Without Having To Shut Of Gas Supplies Or Evacuate The Flow Path For Loading More Samples. Zero Blank Sample Injection System Without Keeping The Whole Auto Sampler Under Inert Atmosphere. Carrier Gas: Possibility Of Using Argon Gas And Helium Gas Both As A Carrier Gas In Chns Mode. Software Should Be Windows Based And Should Have Display Of Set And Actual Pressures, Flow Rates, Temperatures, Number Of Samples Analysed With Provision For Setting Maintenance Interval With Warming When Maintenance Needed.Should Have Segmented Leak Check Through Software To Enable Identification Of Exact Position Of Leak. Consumables:To Be Supplied Withconsumables Sufficient For 1,000 Sample Analysis In Chns/Cns Mode And 1000 Sample Analysis In Oxygen Mode. Microbalance: Microbalance With 0.001 Mg Resolution And Weighing Range: Up To 2000 Mg Or More There Should Be An Interface To Analyser For Direct Transmission Of Weighing Data. Local Supplies: Vendor Should Quote For Complete System Including The Following Items. Sr. No. Details Quantity. 1. Helium Gas Cylinder Of 99.999% Purity Cylinder With Regulator 01 2. Oxygen Gas Cylinder Of 99.999% Purity With Regulator 01 3. Windows 10 Pc (Intel Core I3 Or Better , Ram -At Least 4Gb Ram, Hard Drive-512 Gb Or More, Dual Layer Dvd+/-R W Drive, Ethemet-10/100/1000 Mbps (Gigabit) Ethernet, Screen Size-14.5 Or More, At Least 3 Usb 2.0 Ports.Windows 10, 64-Bit), Black & White Laserjet Multi-Functional Printer (Print, Copy Scan) 01. Future Upgradation Instrument Should Have The Possibility To Measure Chlorine By Adding Chlorine Detector To The Above System.Instrument Should Have The Possibility To I Measure The Trace Sulphur By Adding Ir I Detector To The Above System Necessary Documents: - 1. Catalogue In Original. 2. All Technical Specifications Should Be Printed On The Manufacturers Catalogue/ Data Sheet. Separate Sheet Will Not Be Actable , Micro Centrifuge: Rotor Capacity: 12 Place Closed Roto With Metal Safety Lid, Maximum Speed Rpm I Rcf (G): 15000 Rpm / 15596 G, Display: Large Backlit Lcd Display, Imbalance Detection: Imbalance Detection With Auto Cut - Off, Noise Level: < 60 Db. Motor Type: (Bloc) Brushless Dc Motor, Timer Setting: 1 To 999 Mins, Speed I Time Setting: 500 To 15000 Rpm / Min-Sec Timer, Dimensions (Wxdxh) In Mm: 230 X 262 X 131 Mm, Rotors And Adaptors (Included In Standard Pack): 12 Place X 1.5/2.0 Ml Micro Tubes, Reduction Adaptors For 0.2 Ml Micro Tubes, Reduction Adaptors For 0.4/0.5 Mlmicro Tubes, Pcr Strip Rotor (2 X 8 X 0.2 Ml With Metal Safety Lid) , Deep Freezer:Internal Volume (Liters): 200, No. Of Trays: 02, Internal Dimension Wxdxh (Mm): 640X755x430, External Dimension Wxdxh I 03 (Mm):800X975xl020, Minimum Temperature: - 20°C, Insulation (Cfc Free Polyurethane Foam) 70 Mm Minimum For Body & 80 Mm For Door Temperature Control: Microprocessor, Display: I - 7 Segment, Big Size Led, Power Failure Alarm: Audio Visual Alarm, Door Open , Biotechnology , Uv-Vis Spectrophotometer : Spectral Range-190 To 1100 Nm, Bandwidth-2 Nm, Readability-0.1 Nm, Accuracy-± 0.5 Nm, Repeatability-± 0.2 Nm Or Better Photometric, Range-± 2.500 Abs Accuracy-± 0.005 Abs At 1.0 Abs-± 0.010 Abs At 1.5 Abs Repeatability-± 0.003 Abs At 1.0 Abs Stability (Baseline)-± 0.003 Abs/Hr. After 2 Hour Warm Up Stray Light-<1% T At 200 Nm With Kcl 12G/L -<1% T At 220 Nm With Nai 10G/L Readability-%T-0.01 Abs-0.0001 Or Better Spectrum Mode -A Sample Spectrum Is Recorded Using Wavelength Scanning. The Peak/Valley Pick Function To Select Maxima And Minima And Perform A Wide Variety Of Data Processing Functions, Quantitative Mode, Kinetic Mode, And Time Scan Mode, Biomethod Mode Monochromatorlight Source Deuterium Lamp (D2) & Tungsten (W) Halogen Lamp Detector - Silicon Photo Diode Pc Connectivity-Usb Interface , Benchtop Microscope:Upright Bright Field, Digital Benchtop Microscope With Inbuilt Integrated Tablet Display (No Eyepiece), Application And Research Grade Optics • Detachable Digital Head With Internal Magnification 10X • True View Technology For Capture Of 100% Circular Field Of View Through The Tablet Camera; Captured Field Of View: Diameter 5 Mm With 4X Objective, 2 Mm With 10X Objective, 0.5 Mm With 40X Objective And 0.2 Mm With 100X Objective • Quadruple Inward Facing Nosepiece • Four High Contrast Infinity Corrected Plan Chromate Objective Lenses – 4X, 10X, 40X, 100X Oil Immersion • 1.25 Na Condenser; 3 Watt Led Illumination With Intensity Control • Reckless X-Y Stage • Double Plate Stage Size 190-140 Mm • Coaxial Coarse And Fine Focus Knobs • Tablet With Maximum Camera Resolution Of Atleast 3264X2448 Pixels And 9.7” Display With 2048 X 1536 Pixels Resolution; 3Gb Ram, 32 Gb Rom • Full Hd Video Capture At 1920X1080 Pixels • Pre-Installed Application With Following Features: • Data Management • Image Capturing • Video Recording • Exposure, Brightness, Saturation, Temperature And Contrast Control • Micrometry – Linear And Circular Measurements In Microns • Annotations And Text Addition • Free Hand Marking And Pointer For Demonstration • Profile Creation For Separate Users • Variable Resolution Of Up To 8 Mp • Wireless Hdmi Dongle For Lag-Free Real Time Casting To Projector Or Lcd Screen (Accessory) , Ph Meter : Measuring Range: 0. 00 To 14. 00Ph Measuring Error: ±0. 1Ph Resolution: 0. 01Ph Display: 3 Digits Temperature Compensation: 5 To 50 Celsius One Point Calibration Power Supply: 2 X 3V(Cr2032), 1000Hours , Centrifuge: Refrigerated High Volume High Speed Centrifuge, Floor Model, Calibration Window On Lid For Speed, Display Led, Parameter Setting – Feather Touch Keys, Temperature Display C, Automatic Rotor Identification, Motor Overload Protection, Imbalance Detection With Centrifugation Cut Off, Maximum Speed 20000 Rpm, Min Temp -8C, Noice <60Db, With Following Fixed Angled Rotors – (1) Capacity 12X15 Ml Speed 18000 Rpm.(2) Capacity 8X50 Ml Speed 16000 Rpm, (3) Capacity 24X1.5 Ml Speed 20000 Rpm With Suitable Voltage Stabilizer , Smart Qled Tv : Screen Size 82 , Resolution 7,680 X 4,320, Picture Engine Quantum Processor 8K, Hdr -Quantum Hdr 32X. Sound Dolby Digital60w, Bluetooth Audio, Tv To Mobile - Mirroring, Mobile To Tv - Mirroring, Dlna Video Player, Camera Support, Wi-Fi Direct, Sound Mirroring, Digital Broadcasting, Analog Tuner, Hdmi 4, Usb3, Component In (Y/Pb/Pr) 1, Composite In (Av) 1 (Common Use For Component Y), Ethernet (Lan), Digital Audio Out (Optical), Wireless Lan Built-In , Anynet+ (Hdmi-Cec), Ipv6 Support, With Necessary Accessories , Colorimeter: Microprocessor Photo Colorimeter – Compact And For Colorimeter Analysis Of Any Concentration. Output - 3 Digit Seven Segment Red Led Display In Terms Of %Transmission (%T), Absorbance (Abs.), And Concentration (Conc.) And Kf Actor. The Instrument Should Include A Wide Range Of Filters Covering Wavelength From 420-680 Nm In The Form Of In-Built Filters. The Filter Setting Should Controlled By A Rotating Disc. An In-Built Shutter Control Should Be Provided To Avoid Fatigue Of Photodiode. When The Instrument Is Switched On, Lamp Glows And Light Passes Through The Solution To The Detector And Absorbance Or %T Measurement Is Taken. Light Source - Pre-Focused Tungsten Lamp. The Instrument Should Confirm To All General & Safety Standards. Features: %T, Abs, Conc. K Factor 1 Ml Sample Volume Auto Zeroing Facility Highly Stable & Accurate Range 400 To 700 Nm Soft Touch Membrane Keys , Fermenter : Vessel Designs ? Capacity – 2 Lit ? Working Volume – 1.4 Lit ? Alp. Line Technology (Advance Leakage Prof) For Zero Contamination ? Top Driven Pmdc Brushless Motor ? Glass Vessel With Glass Jacketed ? Top Plate With Acid, Basic, Antifoam, Air Out Let, Air In Let ? Top Plate Having Sensor Port For Inoculums Port With Rubber Septum Lur Lock System And Level Sensor ? One Extra Port For Upgrade ? Sensor Port @ Top Plate For Ph, Do,Co2, Total Bio Mass, Temp Sensor Can Be Fitted Impeller & Baffles ? Type : Ruston Turbine ? No Impeller : 3 No (Adjustable) ? No Of Blades : 6 No ? Baffles Size : 10 % Of The Dia Of Vessel ? Baffles Height : 80 % Of Vessel Height ? Baffles Type : Removable ? Baffles No : 4 No Sampling Device Comes With Unique Device Zero Ded Sampling Complete Contamination Free, Auto Cleavable Glass Container Comes With 0.22 Micron Filter With Vacuum Syringe Device Inoculation System Absolutely Contamination Free Lur Lock Rubber Septum/ Serializable Direct Connection With Sterile Container / Sterile Syringe Air Spurger ? Air Spurger : S.S. 316, ? Type : Ring Type ? Design : Dn 3/8 “ S ? Air Inlet & Out Let Filter ? Inlet Filter : 0.2 Micron Ptfe ? Outlet Filter : 0.2 Micron Ptfe ? Type : Auto Cleavable Controlled Parameter: ? Microprocessor Controlled Unit ? Temperature : Pid Controlled, 4 To + 70° C, ? Pt 100 Rtd Sensor, Plc Controlled ? Amplifiers, Temp Controlled Via Chiller/Circulator (It Should Be Purchased From Optional) ? Aeration : 0 To 10 Lpm With Rota Meter, ? Passed Through 0.22 Micron Filter ? Agitation : 30 To 1200 Rpm, With Programmable ? Drive 5 To 300 Rpm With Programmable Drive ? Ph Measurement : 0 To 14 Ph, Gel Filled Autoclavable ? On Line Ph Probe. Controlled Via Peristaltic Pump Comes With Probe, Cable & Transmitter High Diffusion Aeration System, High Gas Transfer Rate Agitation With Low Mechanical Force, Low Energy Consumption, High Oxygen Transfer Rate, Acid And Basic Dosing Peristaltic Pump ? Dosing Of Min 0.3752 Ml, 0 To 100 % ? Programmable As Per Scientist Application ? Pump Motor Equipped With Visitor For Electric Noise, Suppression, Screw Less & Compact Pump Can Standardized As Per Application Antifoaming Controlling System ? Comes With Autoclavable Conductivity Base Sensor ? Controlling Via Peristaltic Pump ? Comes With Probe, Cable & Card Controller ? Pump Can Standardized As Per Application Air Compressor (Pump) Capacity : 25 Lpm, Operate : 220 Volt Ideal : 1 L To 15 L Fermenter / Bioreactor (Autoclavable) Oil Free Air Pump , Palm Pcr: No. Of Wells - 24, Real-Time Channels -6, Pcr Speed- As Fast As 9 Min/30-Cycles, Sensitivity - Down To Single Copy, Throughput - Over 400 Tests/8-Hours, Portability - = 4 Hours Continuous Pcr Operation Per Single Charge Of A Battery , Co2 Incubator:Volume 40-42 L, Temperature Ambient +5 To 50C, Accuracy +/- 1C, Co2 Range 0 To 20%, Co2 Sensor Tc, Humidity Source - Water Pan, Material Ss, Single Door, Microprocessor Controller, With 1. Compatible Co2 Gas Regulator, 2. Co2 Cylinder 15 Kg Capacity , Chemistry Deptt. , Fuming Hood: Rectangular, Standard Size, Plastic/ Fibre Fabricated Range 30-50 Degree , Catalytic Reactor / Photochemical Reactor: Capacity 100-500Ml, Lamp: 250-400 Watts , Deptt. Of Physical Educaton , Digital Body Composition Monitor: • Step On Analyzer Function • Fat Percent And Subcutaneous; It Utilizes 8 Sensors On Both Hands And Feet For Complete Body Measurement • Memory Support With 4 Memory Presets •Monitor: Body Weight, Bmi, Segmental Body Fat %, Skeletal Muscle, Progress Chart Visceral Fat Level. • Digital Screen With Back Light. , Emg Biofeedback Instrument: • Emg Biofeedback Equipment Is Used For Controlling Ongoing Contraction And Relaxation Patterns. • The Equipment Has Been Developed As Per The International Quality And Norms. • It Highlights Awareness Of The Mechanism Of Muscle Flexure And Develops Voluntary Control Over Dysfunctional, Semi Voluntary Or Involuntary Muscle Activity. • Uses To Redress Disorder Related To » Psychological, » Psychosomatic » Stress • 4.0 Hp Dc Motor • Is-Level Auto Incline For Intense Workout I • Led Display • Time, Speed, Distance, Calories, Heart Rate And Incline ~ Max User Weight: Iso Kg • Speed: 0.8 To 20.0 Km/Hr With Speed Select Hot Keys • 12 Pre-Set Programs For Efficient Workout & 3 Target Based Modes • Connect Usb/Aux Cable To Play Music Directly On The Hi-Fi Speakers • Heart Rate Sensor On Crossbar Handle , Computerized Treadmill: • Comfort Tech Commercial Grade Damping System With Power Spring Shock Absorption To Reduce Stress On Your Joints. • Mobile & Tablet Holder For Safe Keeping Your Smart Devices While Running • Hydraulic Soft Drop System(Hss) For Easy Folding & Unfolding • Running Surface (L X W) - 1400 X 500Mm 1 55.1 X 19.6 Inches • Semi-Auto Lubrication For Easy Maintenance • 360 Degree Rotating Bottom • Wheels For Easy Transportation , Multifunction Pedometer: Waterproof Full Color Amoled Touchscreen 0.95 Inch (2.41 Ems) Amoled Touch Large Color Screen: Adjustable Screen Brightness, Dynamic And Vivid Display; Hence Button Control, Belt Clip Design Makes Band Firmly Attached To Your Wrist. Sp02 Monitor- Sp02 Monitor Tracks Oxygen Saturation Levels In The Bloodstream So You Can Assess How Your Body Is Adapting During Workouts, Heart Rat Monitoring: Tru Seen Allows 24 Hours Accurate Real-Time Heart Rate Monitoring And Warnings On Standby Time Up To 14 Days And Saves Time On Frequent Charging. Multiple Sports Modes: Supports Outdoor And Indoor Run, Walking Indoor And Outdoor Cycling, Pool Swim And Training Various Exercises Types Satm 50 Meters Water-Resistant, Swimming Posture Recognition. 6-Axis Sensor Recognizes Main Strokes, Records: Speed Distance. Number Of Turns, Calories, Average. Average Swolf, And Other Data. Daily Activities Tracking And Monitoring: Step, Count, Calories Burned, Distance Covered, Moderate To High-Intensity Activities Duration And Standing Status Target Setting And Achievement Reminder , Force Place Logger Sensor With Required Accessories: - Dimension 11.2X10.7X2.4 Inches, 3.5Kg - Height 2-1/2 Inches - Force Plate Logger Sensor For Measuring Constant And Changing Forces - Can Be Use3d To Study Newton’S Laws Of Motion, Kinetic And Potential Energy And Gravitational Force Strength For Further Research. - Functions As Scale For Calculating Weight Or Pulling And Pushing Pressure. - Experiment Duration Of 1.0 Second To 31.0 Days For Versatile Use, With 16-Bit Analog To Digital Converter (Adc) Resolution For Reading Rang Of Values. - Accessories: A. Usb Module(Usb 200) To Consentvia Usb Cable To Pc Or Mac Or A Wi-Fi Module (Wifi201) And Battery (Bat200) To Connect To Any Wifi Enabled Device (Smart Phone, Tablet, Computer) , Forge Punching Plate With Required Accessories: - Dimension 12X11x2inches, 3.5Kg - Force Plate Logger Sensor For Measuring Constant And Changing Forces - Can Be Use3d To Study Newton’S Laws Of Motion, Kinetic And Potential Energy And Gravitational Force Strength For Further Research. - Functions As Scale For Calculating Weight Or Pulling And Pushing Pressure. - Experiment Duration Of 1.0 Second To 31.0 Days For Versatile Use, With 16-Bit Analog To Digital Converter (Adc) Resolution For Reading Rang Of Values. Accessories: A. Usb Module(Usb 200) To Consentvia Usb Cable To Pc Or Mac Or A Wi-Fi Module (Wifi201) And Battery (Bat200) To Connect To Any Wi-Fi Enabled Device (Smart Phone, Tablet, Computer) , Digital Back And Leg Dynamometer: For Measuring The Strength Or The Back And Leg - Dimensions: Approx.315(W)X315(D)X328(H)Mm - Weight: Approx. 3.7Kg (Including The Weight Of The Handle) - Automatic Stop: Approx... 1 Min. After The Final Measurement. - Power Source: Dry Battery Sum -4X2 - Display: Lcd In 6 Digits. - Range:20-300Kg. - Graduation: 0.5Kkg. - Accuracy+/-/6.0Kg - Provides A Base For Sure Footing, A Large, Easy-To-Read Display And An Adjustable Hand-Grip Chain To Accommodate Height Differences. Adjustable Chain Accommodates Most Heights , Anthropometry Kit:Includes: 1. Digital Skinfold Caliper 2. Anthropometric Tape Measure 3. Small Bone Anthropometric 4. Calibration Dowel 5. Segmometer Tape 6. Harpenden Anthropometric Set • Aluminum In Construction • Compact Size • Optimum Design , Deptt. Zoology , Distilled Water Plant : Capacity 6 Liter/Hour. Manesty Type Distillation Unit Designed To Provide Pyrogen-Free Distilled Water. Complete Unit Made Up Of Non-Corrosive Steel-Argon Welded. The Lid Perfectly Rest And Get Inside The Collar On The Head Of The Tank Which Avoids Loss Of Steam And Jumping Of Lid. The Unit Fitted With Immersion Type Heating Element. Provided With Iron Bracket To Be Fixed On The Wall. Operates On 230 Volts Ac Single Phase 50 Hz , Double Distilled Water Plant: Silica Heater. • Gate Value To Prevent Water Wastage. • Flow Switch For Boiler Safety. Teflon Drain Cock For Easy Maintenance., High Quality Distillate., Power Coated Stand. • Safety Built - In. Provided With A Threaded Connection For Easy, Safe And Quick Assembly Of Silica Heater. • The Boiler Is Provided With A Teflon Screw Cock For Easy Cleaning Of The Boiler • All Plumbing Connections Are Via Screw Thread Connectors With Silicon Rubber ‘O’ Rings. This Facilitates Easy Fitting And Removal Of Hose, Without Using Excessive Force, Avoiding The Danger Of Glassware Breakage During Assembly. • With Over Heat Protection : Pressure Temperature Switch (Pts): Shuts Off The Unit When Water Level In The Boiler Falls Below The Heater. Output 4 Ltrs/Hr Distilled Water Quality: Ph 5.5 - 6.0 Conductivity 1.0 - 2.0 ?S/Cm. Distillate Quality Pyrogen Free. Electrical Power 220/240V, 50/60 Hz Single Phase, 3 Kw Silica Heater , Microwave Oven: Convection: Grilling, Reheating, Defrosting And Cookin Capacity- 32L Also Included In The Box: Glass Tray, Rotating Ring, Metal Tray ( Tawa), Rotisserie Bar, Rotisserie Handle, Shelf, Owner Manual, Recipe Manual, Cook Book, Healthy Heart Booky , Shaking Incubator :I)Internal Volume: 215 Literii) Platform Size: 580 Mm X 600 Mm Iii) Maximum Shaking :100Ml X 49,150Ml X Capacity (Volume X 49, 250 Ml X 33, 500Ml No. Of Flasks) X 24, 1000Ml X 15, 2000 Ml X 9 Iv) Shaking Speed Range: 20 To 250 Rpm V) Shaking Amplitude : 25 Mm Vi) Internal Dimensions : 660 X 765 X 650 W X D X H (Mm) Vii) Internal Dimensions : 800 X1150x1300 Wxdxh (Mm) Viii) Temperature Control : Microprocessor With Pt100 Sensorix)Display: 4 Lcd Screen, Large Size Display For Ease Of Reading X) Power Failure Alarm: Audio Visual Alarm Xi) Door Open Alarm : Audio Alarm In Case Door Open For Over One Minute Xii) Temperature Variation Alarm: Set Temperature ± 2°C, Audio Visual Alarm Xiii) Illumination: 8 Watts Fluorescent Tube Xiv) Internal Body Material: Stainless Steel – 304 Gradexv) External Body Material: Powder Coated Crca Steelxvi) Insulation (Cfc Free: 70 Mm Minimum For Body & 80 Mm For Door Polyurethane Foam)Xvii) Noise Level: Less Than 65 Db (A) , Laminar Flow: Autoclave Vertical (Present Automatic Digital) Working Chamber Size 30 X 50 Cm (12X20’’) / 35 Carrier (Ø X D) In Cm : 1 Of 25 X 45 Heater 1.80 Kw • Automatic Purging For Efficient Sterilization. • Preset (At 121°C) Digital Temperature Indicator Cum Controller Linked To A Preset (20 Min) Timer. • Low Water Level Cut Off. • End Of Cycle Buzzer. • Fitted With A Safety Valve For Added Safety. • Supplied With Traceable Certificate For Pressure Gauge And Temperature Indicator. • Construction: • Inside And Outside Chamber Are Fully Stainless Steel. • Hydraulically Die Pressed Lid From Stainless Steel Plate. • Flange, Fly Screw, Cross Pin, Heater Cover Stand Are Also Fully Stainless Steel. • All Internal Joints Argon Welded, Ground And Polished To Give Crevice Free Internals. • Preset Digital Temperature Indicator Cum Controller Linked To A Preset Timer 93300/- 18% 16794/- 110094-00 With 1ºc Resolution And ±1ºc Accuracy. • Pt100 Sensor For Precise Control And Monitoring. • Low Water Level Cut Off. • Industrial Grade Energy Efficient Ring Type Heater, Custom Made For Autoclaves, Thus Reducing Power Bills By 16 To 40%. • Lid Is Fitted With Pressure Gauge, Safety Valve/Safety Fusible Plug, Manual Exhaust Valve & Vacuum Breaker Cum Purge Valve. • Moulded Rubber Gasket. • Drain Valve On Side At Bottom For Easy Cleaning. • Stainless Steel Wire Mesh Carrier And Heater Cover Stand. , Autoclave: Autoclave Vertical Fully Automatic • Autoclave Vertical With Chamber Capacity Of 53 Ltr. With All Accessories • Supplied With Two Surgical Drum Of Ss Of 304 • The Chamber Of Vertical Autoclave Manufactured As Per Asme Standards. • The Lid Is Equipped With Single Lever Lock Mechanism And Lever Handle Moulded From Industrial Plastic. • The Lid Provided With Auto Purge Cum Vacuum Breaker Valve And A Manually Operable Valve For Exhaust • The Unit With A Solenoid Valve For Auto Purging Of Air & Normal Exhaust. • The Vertical Autoclave Is Stainless Steel Pressure Gauge With Dual Range Dial Display In Kpa And Psi Along With A Correlated Temperature Scale For Steam In Degrees Celsius. • The Operations Of The Unit Controlled By A Microprocessor Based Controller. • The User Able To Set The Temperature Up To 122°C In Steps Of 0.1°C Each. • The User Able To Set The Sterilization Hold Time In Steps Of 1 Minutes Each. 162600/- 18% 29268/- 191868-00 • The Timer Range Up To 95 Mins. • In Case Of Abrupt Power Failure / Switching Off, The Last Cycle Which Was Set Is Remain In The Memory. • The Display For The Parameters Two Line Alpha-Numeric Digital Display. • Equipped With Low Water Detection Unit And Give Audio- Visual Alarm In Case Of Low Water In The Chamber And Cut Off The Supply To The Heater. • The Unit Is Safety Valve To Protect The Equipment In Case Of Over Pressurization. • The Lid Equipped With Pressure Interlock Device. Also The Heater Is Not Start If The Lid Is Open. • The Unit Provided With Safety Cut-Out For High Temperature. • The Unit Give Indication By Audio-Visual Alarm On Completion Of Set Autoclave Cycle. • The Electrical Safety Is Ensured By Inbuilt Mcb. • The Unit Mounted On 04 Nos. Pu Coated Castors Out Of Which At Least 2 Is Have Locking Mechanism • Work On The Domestic Power Supply Of : 230 V Ac, 50 Hz, Single Phase • Usable Inner Dimensions Ø 350 X 550 • The Units Internal Chamber, Cover Lid And All Wetted Parts Is Fabricated From Stainless Steel Of 304 Grade. • All Joints Is Smooth Finished For Crevice Free Internals. • The Chamber Is Hydrostatically Tested At 1.5 Times Of Its Working Pressure. • The Outer Body Made Up Of Ms Sheet With Heat Cured Epoxy Coating On Both Sides. • The Vertical Autoclave Is Ce Certified. • Calibration Reports With Nabl Traceability , Colorimeter: Microprocessor Photo Colorimeter With 8 Glass Filters Covering Range Of 400- 700 Nm With Facility For Auto Concentration, %Transmission, And Absorbance And K Factor Measurement. It Has 16X2 Line Lcd Data Display. Its Sample Holder Accommodates Glass Test Tubes Of 10Mm Path Length. Facility Has Been Provided For 100 Sample Data Storage And Interface For Any Centronics Printer. , Deep Freezer: With Fridge Freezer Convertible Technology, The 535 L Capacity Range Convert The Chest Freezer To A Chiller As Well Allowing You To Chill Beverages Like Milk Or Colas Etc. The Tropical Compressor, Suited For Harsh Indian Summers, Comes With A 5 Year Warranty As Well. Whats More, The Machine Uses The Worlds Most Ecofriendly R290 Refrigerant Making It Power Saving And Also Planet Friendly. Convertible Technology,100% Environment Friendly,360 Degree Castor Wheels, Compressor Warranty, Anti-B Technology, Anti-Rodent Cabinet ,Bright Led, Door Lock, Drainage System, Faster Pull Down Time Power Saving Operation, Stucco Aluminuminteriors, Thick Puf Insulation Tropicalized Compressor , Deptt. Of Physics , Uv-Vis-Nir Spectrophotometer -- Light Source-Tungsten-Halogen And Deuterium, Operating Wavelength Range-175 - 3300 Nm, Capable To Capture Diffuse And Specular Reflectance , Micro Hardness Testing Machine – Manual Xy Stage Provided As Standard With Surface Area: 100 × 100 Mm, Stroke: ±12.5 Mm (0 To 25 Mm) For Both The X Axis And Y Axis Positioning Accuracy: 0.02 Mm / 10 Mm Data Processing Functions: ? Vickers Hardness Hv ? Knop Hardness Hk*4 ? Brignell Hardness: Hb*4 ? Triangular Pyramid Hardness Ht ? Length, Direct Reading L (?M) ? Fracture Toughness Kc ? Shape Correction Function , Quinck’S Tube Method: Paramagnetic Sample, Electromagnet, Travelling Microscope, Solid Sample , Digital Source Meter: High Resolution Capacitive Touch Screen Graphical User Interface,V-Ranges: 200 Mv – 200 V, I-Ranges: 1 ?A – 1 Or I-Ranges: 10 Na – 1 A, 0.012% Basic Accuracy, Wideband Noise: 4 Or 2 Mvrms Typ.,Sweep Types: Linear, Log, Custom, Programming Gpib, Usb, Ethernet (Lxi) , Potentiostat - Galvano Stat: Voltage Polarization Range ± 2 V With Factory Option To ± 8 V Current Polarization Range ±20 Ma Maximum Compliance ±8 V Rise Time 1 V/?Sec Into 1 K? Connections Differential Electrometer Maximum Voltage Measurement ± 2 V With Factory Option To ± 8 V Maximum Resolution 61 ?V Maximum Current ±20 Ma Ranges 1 Na/V To 10 Ma/V In 8-Decade Ranges Maximum Resolution 61 Fa Compliance Voltage ±8 V , Sputtering System: Two Target Dc Sputtering System Confocal Sputter Configuration Manual Orsemi-Automatic Or Fully Automatic Mode Turbo Molecular Pump Based High Vacuum Pumping System Base Pressure: 10-7 Torr By Using Suitable Capacity Turbo Molecular Pump Electro-Polished Process Chamber From Inner And Outer Side For Better Vacuum Performance Extra Ports For Future Up-Gradation Rf/Dc/Pulsed Dc Compatible Sputtering Sources Manual Or Motorized Shutter Assembly Size 1” Or 2”Or 3” High Strength Magnets Substrate Holder To Hold Various Sizes Of Substrate Up To 4” Dia. Variable Substrate Rotation Up To 30 Rpm Uniform Substrate Heating Up To 600 Deg C Mass Flow Control Base Gas Management System With Digital Display And Controller For Nano Technology, Photovoltaic Coating, Metals, Metal Oxides And Dielectric Coatings Applications , Dc Variable Power Supply : Range 0-30V (Dual) , Analytical Balance:Accuracy:0.01Mg, Range 120G 0R 200G , Universal B-H Curve Tracer --Complete Experimental Setup , Electromagnet With Power Supply : 15Kgauss Magnetic Field Maximum 15Kgauss , Board Of Innovation, Incubation & Linkages , Stand-Alone Ups For Desk Top Computers : Latest Updated Version , Webcam: Full Hd 1080P Webcam For Pc Laptop Desktop, Usb Webcam , Headset (Headphones And Microphone): Wired Headset, Stereo Headphones With Noise-Cancelling Microphone, 3.5 Mm Audio Jack For Pc / Laptop , Speaker Phone For Pc: Computer Microphone, Usb Desktop Computer Conference Omni-Directional Condenser Microphone Mic Speaker Speakerphone 360° Audio Pickup Plug & Play For Business Video Meeting , Portable Light For Webinar : Table Lamp , Light For Photo And Video: Led Ring Light For Photo And Video With Tripod Stand Compatible With Camera And Smartphone , Drawing Pen Tablet: Digital Graphics Drawing Pen Tablet (10 X 6.25, 8192 Levels Of Pressure Sensitivity, Battery-Free Passive Stylus , Rollup Banner Stand: Aluminium Retractable Rollup Banner Stand For Store Display/Trade Show (3 X 6 Ft , White Boards: Non-Magnetic 2X3 Feet Double Sided Both Side Writing One Side White Marker And Reverse Side Chalk Board Surface (Pack Of 1, Size 2Feet X 3Feet, White & Green) , Pin-Up Board:Fabric Notice Board/Pin-Up Board/Soft Board/Bulletin Board With Lightweight Aluminium Frame (Green, 1.5X2 Ft) , Research & Incubation Foundation Centre. , Stand-Alone Ups For Desk Top Computers , Arduino Uno , Arduino Nano , Arduino Ic(Atmega 328) , Ultrasonic Sensor , Servo Motor , Jumper Wires , Relay Module (2 Channel) , Relay Module (4 Channel) , Zero Pcb , Esp 8266 , Gsm Module , Gps Module , Bluetooth Module , Dht 11 , Mq 135 , Breadboard 840 Points , Mini-Breadboard 170 Points , Ir Infrared Obstacle Avoidance Sensor , Soil Moisture Sensor , Rc522 Rfid Card Sensor , Joy Stick Module , Potentiometer 10 K , Potentiometer 47K , Hdmi To Vga , Solar Panels , Raspberry Pi Camera , Usb To Ttl , Raspberry Pi 3 Lcd Display , Accelerometer Sensor , Sensor Kit , Webcam , Headset (Headphones And Microphone) , Speaker Phone For Pc , Portable Light For Webinar , Light For Photo And Video , Drawing Pen Tablet , Rollup Banner Stand , White Boards , Pin-Up Board , Combination Spanner Set (Taparia)6 To 32Mm (Set) , Adjustable Spanner (Taparia) 300Mm , Spirit Level24 , Screwdriver Two In One (Taparia) 375Mmx6mm , Screw Driver Two In One Set (Taparia) 150Mm,200Mm, 250Mmx6mm (Set) , Needlenose Plier (Taparia)150Mm , Circlip Plier Straight (Taparia) 150Mm , Circlip Plier Bent (Taparia) 150Mm , Combination Pliers (Taparia) 200Mm , Pliers And Snips (Taparia) 150Mm , Ball Peen Hammer (Taparia) 300Gm , Electrical Hand Drill Machine With Reverse Andforward (Dewalt) 13Mm , Measuring Tap ( Uken) 5Meter , Try Square(Taparia) 150Mm , Steel Rule (Kristeel) 300Mm , Vernier Caliper (Yamaha) 200Mm , Allen Key Set Inche & Mm Eachone (Set) , Hand Grinder (Dewalt) 4-1/2” , Half Round Smooth File (Jk) 250Mm , Triangular Smooth File (Jk) 200Mm , Heavy Duty Hacksaw Frame (Taperia) 12” , C Calmp (Taparia) 8” , Grip Wrench (Taparia) 125Mm , Universal Pliers (Taparia) 200Mm , Double Universal Spanner (Taparia) 9Mm To 32Mm , Vice , 3D Printer For Rapid Retyping , Boy’S Hostel , Camera: Projector Handy Cam Hdrpj 660, 96 Gb Memory, Built-In Projector With External Input, 1920X1080 Full High Definition, 20Xextended Zoom, 20.4 Mp Still Image Reroofing, Filterdiameter 46Mm, G Lens, 3.0 (7.35Cms) Wide Lcd, Face Detection, Battery: Np-Gv50, Light+Flash: Hvl-Vpl-10Nh, Mic: Ecm-Hw2, Tripod: Vct-Vpr1, Cable; Vmc-15Mr2, Screen Protector: Pck-L30wd, Charger : Bc-Trv , Finance And Accounts Section , Ups 10 Kva (Half Hour Backup) Branded Company , Knowledge Resource Centre , Intel Core Computer : Intel Core I7 Configuration(64 Bit) A. Cpu: Intel Core I7-2600, 3.4 Ghz, 8 Mb Cache Or Better. B. Chipset: Intel Q67 Express Or Higher On Oem Motherboard. C. Bus Architecture: 4 Pci (Pci/ Pci Express) D. Memory: 2 Gb 1066 Mhz Ddr3 Ram With 8 Gb Expandability. E. Hard Disk Drive: 320 Gb 7200 Rpm Serial Ata Hdd Orhigher. F. Monitor : 47 Cm (18.5 Inch)Larger Led/ Tft Digital Color Monitor Tco- 05 Certified. G. Keyboard: 104 Keys. H. Mouse : Optical With Usb Interface. I. Bays : 3 Nos. Or Above. J. Ports : 6 Usb Ports (With At Least 2 In Front), Audio Ports For Microphone And Headphone In Front. K. Cabinet : Small Form Factor (Max. 16 Litres). L. Dvd Rom Drive : 8X Or Better Dvd Rom Drive. M. Networking Facility: 10/100/1000 On Board Integrated Network Port With Remote Booting Facility Remote System Installation, Remote Wake Up,Out Of Band Management Using Any Standard Management Software. N.Operating System: Windows 7 Professional / Rhel / Suse Linux Preloaded, As Specified, With Media Anddocumentation And Certificate Of Authenticity. O. Os Certifications: Windows 7 Os And Linux Certification. P.Power Management : Screen Blanking, Hard Disk And System Idle Mode In Power On, Set Up Password, Power Supply Smps Surge Protected. Q.Preloaded Software: Nortonor Mcafee Or Etrust Or E-Scan Orfore Front Or Trend Micro Or Pc Tool Or Quick Heal Antivirus (Latest Version) With 3 Years License. (Included In Case Of Windows 10 Only) , Access Control System As Per Requirement Ofknowledge Resource Centre : For Main Gate Entry And Reading Room Gate Entry For Krc 1)Single Lane Flap Barriers : Single Line Flap Barrier Pair (L/R) ,Use Ic Card,Id Cards,Barcode Or Magnetic Cards As Automatic Identification System,With Voice & Strobe Lights Alert,Display Has Been Use For Statistic And Numbers,Combination Of Infrared Sensors And Police Anti-Illegal Entry Into Pedestrain Access,Double Anti Clipping System,Passage Width: <= 550Mm,Throughput Rate : 35 P/M,Power Supply : 100V~240V,Max Power Consumption : 30 W,Frequency,50Hz~60Hz,Protection Level (Ip):>=54,Working Temp: -25~+70 Deg, Electromagnetic Drive Dc, Dimension Excluding Bars:800X280x960mm,Weight: 52Kg. , 2)Multi Lane Flap Barriers : Multi Lane Flap Barrieer Use Ic Card,Id Cards,Barcode Or Magnetic Cards As Automatic Identification ,Bidirectional Single Passage,Plastic Toughened Glass.System,With Voice & Strobe Lights Alert,Display Has Been Use For Statistic And Numbers,Combination Of Infrared Sensors And Police Anti-Illegal Entry Into Pedestrain Access,Double Anti Clipping System,Passage Width: <= 550Mm,Throughput Rate : 35 P/M,Power Supply : 100V~240V,Max Power Consumption : 30 W,Frequency,50Hz~60Hz,Protection Level (Ip):>=44,Working Temp: -25~+70 Deg,Electomagnetic Drive Dc,Dimension Excluding Bars:800X280x960mm,Weight: 40Kg, , 3)Access Control System : : Access Control System Fingerprint Capacity : 10000(1:N),Face Capacity :6000(1:N)/10000(1:1),Card Capacity:10000,Transaction Capacity : 10,00,000,Communication : Tcp/Ip,Usb Host,Wiegand Output,Display 4.3 Inch Touch,Cpu 1.2 Ghz,Memory:1 Gb Ram/1 Gb Flash,Silkid Fingerprint Sensor,Hi-Fi Voice & Indicator,Tamper Switch Alarm,Standard Function : Id Card /Wdws,Dst/Sms/Bell Schedule, , 4)Access Control Casing , 5)Card Collector : Rfid Card Reader(125 Khz Proximity Card Reader,Read Range Upto 10 Cm,Reading Time (Card) Less Than Equal 200 Ms,Connectivity-Wiegand,Beeper-Yes,Operating Temperatur:--20 Deg To +65 Deg,Operating Humidity-10% To 90%Relative Humidity Non-Condensing,) ,Door Access Controller(Number Of Door Controlled -2,Number Of Reader Supported-4,Type Of Reader Supported -26 Bit Weigand,Number Of Inputs :6(2 Exit Device,2 Door Status ,2 Aux,Number Of Output 4,Card Holder Capacity -30000,Log Event Capacity-100000,Communication-Tcp/Ip,Rs483,Recommanded Power Supply 12V Dc,1.5A,Card Enroller,P-T-Card Collector , 6) Proximity Card(Thin Card) : Proximity Card (Thin Card)Thin Flexible Polyvinyl Chloride(Pvc) Laminated,Operating Temp 13 Deg To 158 Deg F,Working Frequency :125Khz , 7) Setup,Installation & Supervision Chargesalong With Middle Layer Realtimemonitoringsoftware ,Accessories ,Emergency Gate,Additional Installation Kit For Two Location With One Year Warranty & Additional Five Year Support , Kvm Switch For 4 Serverx1 Monitor, Keyboard And Mouse Inter Connectivity , Cctv System: 1. Setup & Installation Ofip Dome /Bullet 2 Mp,1/2.8 Progressive Scan Cmos,Icr,Colour 0.028 Lux @(F2.0:Agc On),0 Lux With Ir ,1920X1080:25Fps/30Fps (50/60Hz), 2.8Mm/4Mm Lens Fixed,H.265+/H.265/H.264/ Mjpeg, Dc12v & Poe, 3D Dnr, Blc, Roi, Hlc, Wdr,Ir Range: Up To 30M, Cloud Service. 3-Axis Adjustment, Rj45 Ethernet Interface, Line Crossing Detection, Intrusion Detection, Scene Change Detection, Audio Exception Detection, Face Detection, Ip67, Onvif (Profile S, Profile G), Isapi , 2. Setup & Installation Ofip Dome /Bulletcamera 2 Mp,1/2.8 Progressive Scan Cmos,Icr, Colour 0.028 Lux @(F2.0:Agc On),0 Lux With Ir ,1920X1080:25Fps/30Fps (50/60Hz), 2.8Mm /4Mmlens Fixed,H.265+/H.265/H.264/ Mjpeg, Dc12v & Poe, 3D Dnr, Blc, Roi, Hlc, Wdr,Ir Range: Up To 30M, Cloud Service. 3-Axis Adjustment, Rj45 Ethernet Interface, Line Crossing Detection, Intrusion Detection, Scene Change Detection, Audio Exception Detection, Face Detection, Ip67, Onvif (Profile S, Profile G), Isapi , 3. Setup & Installation Ofip Dome /Bulletcamera 2 Mp,1/2.8 Progressive Scan Cmos,Icr, Colour 0.028 Lux @(F2.0:Agc On),0 Lux With Ir ,1920X1080:25Fps/30Fps (50/60Hz), 2.8Mm/4Mm Lens Fixed,H.265+/H.265/H.264/ Mjpeg, Dc12v & Poe, 3D Dnr, Blc, Roi, Hlc, Wdr,Ir Range: Up To 30M, Cloud Service. 3-Axis Adjustment, Rj45 Ethernet Interface, Line Crossing Detection, Intrusion Detection, Scene Change Detection, Audio Exception Detection, Face Detection, Ip67, Onvif (Profile S, Profile G), Isapi , 4. Setup & Installation Of16 Channel Network Video Recorder 2 Mp, H.265+/H.265/H.264/H.264+ Video Formats. 2-Ch@8Mp(25Fps)/4-Ch@4Mp(30Fps)/8-Ch@1080P(30Fps) Decoding Capability,Incoming/ Outgoing Bandwidth 160/160Mbps, Recording At Up To 8 Mp Resolution. Live View, Storage, Playback Of The , 5. Setup & Installation Of64ch Smart Networkhigh Performance Video Recorder: Connect Up To 64Ip Cameras, Linux Os, Up To 12 Megapixels Resolution, Two Independent Hdmi / Vga Output , Support H.265/Mjpeg, Incoming Bandwidth 320Mbps, 8 Sata Hard Disks, Anr Technology, 8 Sata Interfaces Or More For 8 Hdds And Capacity Of Each Hdd Upto 10Tb, N+1 Hot Spare System, Supports Hdd Hot Swap With Raid0, Raid1, Raid5, Raid 6, And Raid10 Storage Scheme Configurable, With Redundant Power Supplyfront Panel: 1 × Usb 2.0 Rear Panel: 2 × Usb 3.0, Alarm I/O 16/8, Rs-485, Rs-232, 4 Rj-45 10 /100/1000 Mbps Self-Adaptive Ethernet Interface,Multiple Network Monitoring, , 6. Hard Surveillance Disk 6 Tb Seagate , 7.Setup & Installation Of Cat6 Patch Panel Unloaded 24 Port , 8. Setup & Installation Of Cat 6 I/O , 9. Cat 6 Patch Cord , 10. Setup & Installation Of 24 Port Network Switch Poe 24 X 10/100/1000Base-T Poe Port,4 X Giga Rj45/Sfp Combo Port , 11. Setup & Installation Of 10 Port Network Switch Poe 8 X 10/100/1000Base-T Poe Port,4 X Giga Rj45/Sfp Combo Port , 12. Setup & Installation Of 6U Networkrack With Standard Accessories , 13. Dome Camera Stand , 14.Cat6 Cable (Cat 6 Patch Cord As Per Actual) , 15. Cable Laying Charges (Asactual) , 16. Conduit Pipe/Casing Pattiwith Scaddle Fitting(Asactual) , 17. Setup, Installation, Crimping, Punching & Supervision Charges With Two Year Warranty. , Director Of Examination & Evaluation & Common Purchase , Tower Air Conditioner 4.0 Ton Make: Carrier Midea India Pvt. Ltd , Tower Air Conditioner 4.0 Ton Make: O. General , Tower Air Conditioner 4.0 Ton Make: Mitsubishi Heavy Industry , Cassette Air Conditioner 4.0 Ton Make: Carrier Midea India Pvt. Ltd , Cassette Air Conditioner 4.0 Ton Make: O. General , Cassette Air Conditioner 4.0 Ton Make: Mitsubishi Heavy Industry , Cassette Air Conditioner: Cap. : 3 Ton 3 Star Rating Inverter Model, Hidden Display, Kw Display, Follow Me, Sleep Mode, 3M-Pm 2.5 Filter, Refrigerant Leakage Detector, Louver Position Memory, Default Set Temp. As Per Bee, Flexicool Remote, Eco Friendly Refrigerant,Make: Carrier Midea India Pvt. Ltd , Cassette Air Conditioner: Cap. : 3 Ton 3 Star Rating Inverter Model, Hidden Display, Kw Display, Follow Me, Sleep Mode, 3M-Pm 2.5 Filter, Refrigerant Leakage Detector, Louver Position Memory, Default Set Temp. As Per Bee, Flexicool Remote, Eco Friendly Refrigerant,Make: O. General , Cassette Air Conditioner: Cap. : 3 Ton 3 Star Rating Inverter Model, Hidden Display, Kw Display, Follow Me, Sleep Mode, 3M-Pm 2.5 Filter, Refrigerant Leakage Detector, Louver Position Memory, Default Set Temp. As Per Bee, Flexicool Remote, Eco Friendly Refrigerant,Make: Mitsubishi Heavy Industry , Split Air Conditioner: Cap. : 3 Ton 3 Star Rating Inverter Model, Hidden Display, Kw Display, Follow Me, Sleep Mode, 3M-Pm 2.5 Filter, Refrigerant Leakage Detector, Louver Position Memory, Default Set Temp. As Per Bee, Flexicool Remote, Eco Friendly Refrigerant, Make: Carrier Midea India Pvt. Ltd , Split Air Conditioner: Cap. : 3 Ton 3 Star Rating Inverter Model, Hidden Display, Kw Display, Follow Me, Sleep Mode, 3M-Pm 2.5 Filter, Refrigerant Leakage Detector, Louver Position Memory, Default Set Temp. As Per Bee, Flexicool Remote, Eco Friendly Refrigerant, Make: O. General , Split Air Conditioner: Cap. : 3 Ton 3 Star Rating Inverter Model, Hidden Display, Kw Display, Follow Me, Sleep Mode, 3M-Pm 2.5 Filter, Refrigerant Leakage Detector, Louver Position Memory, Default Set Temp. As Per Bee, Flexicool Remote, Eco Friendly Refrigerant, Make: Mitsubishi Heavy Industry , Cassette Air Conditioner: Cap. : 2.0 Ton 3Star Inverter Model, Flexi Cool Mode, Hybrid Jet Technology, Hidden Display, Electrostatic Dust Filter, 3M-Pm 2.5 Filter,Refrigerant Cooling Pcb, Durable Inverter Outdoor Pcb, 52°C Ambient Working Ofac,Stabilizer Free Operation, Double Drain System, Default Set Temp. As Per Bee Rating, Flexicool Remote, Eco Friendly Refrigerant,Make:Carrier Midea India Pvt. Ltd. , Cassette Air Conditioner: Cap. : 2.0 Ton 3Star Inverter Model, Flexi Cool Mode, Hybrid Jet Technology, Hidden Display, Electrostatic Dust Filter, 3M-Pm 2.5 Filter,Refrigerant Cooling Pcb, Durable Inverter Outdoor Pcb, 52°C Ambient Working Ofac,Stabilizer Free Operation, Double Drain System, Default Set Temp. As Per Bee Rating, Flexicool Remote, Eco Friendly Refrigerant,Ft.Make: O. General , Cassette Air Conditioner: Cap. : 2.0 Ton 3Star Inverter Model, Flexi Cool Mode, Hybrid Jet Technology, Hidden Display, Electrostatic Dust Filter, 3M-Pm 2.5 Filter,Refrigerant Cooling Pcb, Durable Inverter Outdoor Pcb, 52°C Ambient Working Ofac,Stabilizer Free Operation, Double Drain System, Default Set Temp. As Per Bee Rating, Flexicool Remote, Eco Friendly Refrigerant, Make: Mitsubishi Heavy Industry , Split Air Conditioner: Cap. : 2.0 Ton 3Star Inverter Model, Flexi Cool Mode, Hybrid Jet Technology, Hidden Display, Electrostatic Dust Filter, 3M-Pm 2.5 Filter,Refrigerant Cooling Pcb, Durable Inverter Outdoor Pcb, 52°C Ambient Working Ofac,Stabilizer Free Operation, Double Drain System, Default Set Temp. As Per Bee Rating, Flexicool Remote, Eco Friendly Refrigerant,Including: Copper Piping 10 Rft.& Electrical Cabling 10 Rft. Make: Carrier Midea India Pvt. Ltd. , Split Air Conditioner: Cap. : 2.0 Ton 3Star Inverter Model, Flexi Cool Mode, Hybrid Jet Technology, Hidden Display, Electrostatic Dust Filter, 3M-Pm 2.5 Filter,Refrigerant Cooling Pcb, Durable Inverter Outdoor Pcb, 52°C Ambient Working Ofac,Stabilizer Free Operation, Double Drain System, Default Set Temp. As Per Bee Rating, Flexicool Remote, Eco Friendly Refrigerant,Including: Copper Piping 10 Rft.& Electrical Cabling 10 Rft. Make: O. General , Split Air Conditioner: Cap. : 2.0 Ton 3Star Inverter Model, Flexi Cool Mode, Hybrid Jet Technology, Hidden Display, Electrostatic Dust Filter, 3M-Pm 2.5 Filter,Refrigerant Cooling Pcb, Durable Inverter Outdoor Pcb, 52°C Ambient Working Ofac,Stabilizer Free Operation, Double Drain System, Default Set Temp. As Per Bee Rating, Flexicool Remote, Eco Friendly Refrigerant,Including: Copper Piping 10 Rft.& Electrical Cabling 10 Rft. Make: Mitsubishi Heavy Industry , Cassette Conditioner: Cap. : 1.5 Ton 3Star Inverter Model, Flexi Cool Mode, Hybrid Jet Technology, Hidden Display, Electrostatic Dust Filter, 3M-Pm 2.5 Filter,Refrigerant Cooling Pcb, Durable Inverter Outdoor Pcb, 52°C Ambient Working Ofac,Stabilizer Free Operation, Double Drain System, Default Set Temp. As Per Bee Rating, Flexicool Remote, Eco Friendly Refrigerant, Make: Carrier Midea India Pvt. Ltd. , Cassette Air Conditioner: Cap. : 1.5 Ton 3Star Inverter Model, Flexi Cool Mode, Hybrid Jet Technology, Hidden Display, Electrostatic Dust Filter, 3M-Pm 2.5 Filter,Refrigerant Cooling Pcb, Durable Inverter Outdoor Pcb, 52°C Ambient Working Ofac,Stabilizer Free Operation, Double Drain System, Default Set Temp. As Per Bee Rating, Flexicool Remote, Eco Friendly Refrigerant, Make: O. General , Cassette Air Conditioner: Cap. : 1.5 Ton 3Star Inverter Model, Flexi Cool Mode, Hybrid Jet Technology, Hidden Display, Electrostatic Dust Filter, 3M-Pm 2.5 Filter,Refrigerant Cooling Pcb, Durable Inverter Outdoor Pcb, 52°C Ambient Working Ofac,Stabilizer Free Operation, Double Drain System, Default Set Temp. As Per Bee Rating, Flexicool Remote, Eco Friendly Refrigerant, Make: Mitsubishi Heavy Industry. , Split Air Conditioner: Cap. : 1.5 Ton 3Star Inverter Model, Flexi Cool Mode, Hybrid Jet Technology, Hidden Display, Electrostatic Dust Filter, 3M-Pm 2.5 Filter,Refrigerant Cooling Pcb, Durable Inverter Outdoor Pcb, 52°C Ambient Working Ofac,Stabilizer Free Operation, Double Drain System, Default Set Temp. As Per Bee Rating, Flexicool Remote, Eco Friendly Refrigerant,Including: Copper Piping 10 Rft.& Electrical Cabling 10 Rft.Make: Carrier Midea India Pvt. Ltd. , Split Air Conditioner: Cap. : 1.5 Ton 3Star Inverter Model, Flexi Cool Mode, Hybrid Jet Technology, Hidden Display, Electrostatic Dust Filter, 3M-Pm 2.5 Filter,Refrigerant Cooling Pcb, Durable Inverter Outdoor Pcb, 52°C Ambient Working Ofac,Stabilizer Free Operation, Double Drain System, Default Set Temp. As Per Bee Rating, Flexicool Remote, Eco Friendly Refrigerant,Including: Copper Piping 10 Rft.& Electrical Cabling 10 Rft.Make: O. General , Split Air Conditioner: Cap. : 1.5 Ton 3Star Inverter Model, Flexi Cool Mode, Hybrid Jet Technology, Hidden Display, Electrostatic Dust Filter, 3M-Pm 2.5 Filter,Refrigerant Cooling Pcb, Durable Inverter Outdoor Pcb, 52°C Ambient Working Ofac,Stabilizer Free Operation, Double Drain System, Default Set Temp. As Per Bee Rating, Flexicool Remote, Eco Friendly Refrigerant,Including: Copper Piping 10 Rft.& Electrical Cabling 10 Rft.Make: Mitsubishi Heavy Industry. , Voltage Stabilizer (160V-270V) & (200V - 250V)5.0 Kva Forair Conditioner Of 3 Ton, ,2.0 Ton, , Voltage Stabilizer (160V-270V) & (200V - 250V)4.0 Kva For Air Conditioner Of 1.5 Ton, , M.S. Stand For Air Conditioner 4.0 Ton For Outdoor Unit For Air Conditioner , M.S. Stand For Air Conditioner 3 Ton, ,2.0 Ton, 1.5 Ton , Copper Piping 4 Ton, 3 Ton(Mtr) , Copper Piping 2 Ton , 1.5 Ton (Mtr) , Copper Cable Wire 4Mm X 3Core (Mtr) , Copper Cable Wire 2.5Mm X 3Core (Mtr) , Pvc Hard Drain Piping (Mtr) , Installation Charges For Cassette Air Conditioner , Installation Charges For Tower Air Conditioner , Installation Charges For Split Air Conditioner , Dlp Projector : Native Resolution-Wxga (1280X800) Or Higher, Brightness 4000 Ansi Lumens Or Better, Throw-Long Throw, Keystone & Corner Correction -Projector Should Have Both Vertical (± 30º) And Horizontal (± 20º) Keystone Correction And Four Corner Adjustment, Minimum Lamp Life-15000 Hrs In Normal Mode, 20000 Hours In Economy Modeinput Ports- Hdmi -1 ,Vga - 1, Audio In, Video X 1, Other Ports-Rs 232, Lan(Rj 45) Output Vga, Audio Out, Contrast Ratio-22000:1 Or Better, Optical Zoom-1.1X, Throw Ratio-1.55-1.70 Or Better, Special Features-Usb Reader, Data Over Lan, In-Built Speaker-Minimum 20 Watts Rms To Deliver Full Range Sound 20Hz-20Khz, Input Power Supply-As Per Indian Standard With Compatible Power Cable & Connector Ccessories-All Device Driver And Cables For Connecting With Computer, Remote Projector Should Be Supplied With Full Function Remote Control Having A Laser Pointer Inbuilt In The Remote Control, Other Accessories -Cables (Of 2 Meter Length Hdmi, Power) Should Be Supplied Along With Projector, Bis Registration-Quoted Model Of Projector Should Have Valid Bis Registration . Make:- Golbus , Dlp Projector : Native Resolution-Wxga (1280X800) Or Higher, Brightness 4000 Ansi Lumens Or Better, Throw-Long Throw, Keystone & Corner Correction -Projector Should Have Both Vertical (± 30º) And Horizontal (± 20º) Keystone Correction And Four Corner Adjustment, Minimum Lamp Life-15000 Hrs In Normal Mode, 20000 Hours In Economy Modeinput Ports- Hdmi -1 ,Vga - 1, Audio In, Video X 1, Other Ports-Rs 232, Lan(Rj 45) Output Vga, Audio Out, Contrast Ratio-22000:1 Or Better, Optical Zoom-1.1X, Throw Ratio-1.55-1.70 Or Better, Special Features-Usb Reader, Data Over Lan, In-Built Speaker-Minimum 20 Watts Rms To Deliver Full Range Sound 20Hz-20Khz, Input Power Supply-As Per Indian Standard With Compatible Power Cable & Connector Ccessories-All Device Driver And Cables For Connecting With Computer, Remote Projector Should Be Supplied With Full Function Remote Control Having A Laser Pointer Inbuilt In The Remote Control, Other Accessories -Cables (Of 2 Meter Length Hdmi, Power) Should Be Supplied Along With Projector, Bis Registration-Quoted Model Of Projector Should Have Valid Bis Registration . Make:- Sony , Dlp Projector : Native Resolution-Wxga (1280X800) Or Higher, Brightness 4000 Ansi Lumens Or Better, Throw-Long Throw, Keystone & Corner Correction -Projector Should Have Both Vertical (± 30º) And Horizontal (± 20º) Keystone Correction And Four Corner Adjustment, Minimum Lamp Life-15000 Hrs In Normal Mode, 20000 Hours In Economy Modeinput Ports- Hdmi -1 ,Vga - 1, Audio In, Video X 1, Other Ports-Rs 232, Lan(Rj 45) Output Vga, Audio Out, Contrast Ratio-22000:1 Or Better, Optical Zoom-1.1X, Throw Ratio-1.55-1.70 Or Better, Special Features-Usb Reader, Data Over Lan, In-Built Speaker-Minimum 20 Watts Rms To Deliver Full Range Sound 20Hz-20Khz, Input Power Supply-As Per Indian Standard With Compatible Power Cable & Connector Ccessories-All Device Driver And Cables For Connecting With Computer, Remote Projector Should Be Supplied With Full Function Remote Control Having A Laser Pointer Inbuilt In The Remote Control, Other Accessories -Cables (Of 2 Meter Length Hdmi, Power) Should Be Supplied Along With Projector, Bis Registration-Quoted Model Of Projector Should Have Valid Bis Registration . Make:- Optima , Dlp Projector ,Brightness-4200 Ansi Lumens Or Better, Native Resolution-Wxga (1280X800) Or Higher, .Throw Short Throw, Keystone & Corner Correction-Projector Should Have Both Vertical (± 20º) And Horizontal (± 20º) Keystone Correction And Four Corner Adjustment. Minimum Lamp Life-15000 Hrs In Normal Mode, 20000 Hours In Economy Mode Input Ports-Hdmi -2 ,Vga - 2, Audio In, Video X 1, Other Ports-Rs 232, Lan(Rj 45),Usb Type A For Charging, Output Vga, Audio Out, Contrast Ratio-22000:1 Or Better, Throw Ratio-0.49 Or Better Throw Distance 0.63M-1.9M (100 @ 1.06M), Digital Zoom-0.8X-2.0X, Aspect Ratio-16:10 In Built Speaker Minimum 10 Watts Rms To Deliver Full Range Sound 20Hz-20Khz Input Power Supply-As Per Indian Standard With Compatible Power Cable & Connector Accessories-All Device Driver And Cables For Connecting With Computer, Remote Projector Should Be Supplied With Full Function Remote Control Having A Laser Pointer Inbuilt In The Remote Control Other Accessories -Cables (Of 5 Meter Length Hdmi, Power) Should Be Supplied Along With Projector, Bis Registration Quoted Model Of Projector Should Have Valid Bis Registrationmake : Globus , Dlp Projector ,Brightness-4200 Ansi Lumens Or Better, Native Resolution-Wxga (1280X800) Or Higher, .Throw Short Throw, Keystone & Corner Correction-Projector Should Have Both Vertical (± 20º) And Horizontal (± 20º) Keystone Correction And Four Corner Adjustment. Minimum Lamp Life-15000 Hrs In Normal Mode, 20000 Hours In Economy Mode Input Ports-Hdmi -2 ,Vga - 2, Audio In, Video X 1, Other Ports-Rs 232, Lan(Rj 45),Usb Type A For Charging, Output Vga, Audio Out, Contrast Ratio-22000:1 Or Better, Throw Ratio-0.49 Or Better Throw Distance 0.63M-1.9M (100 @ 1.06M), Digital Zoom-0.8X-2.0X, Aspect Ratio-16:10 In Built Speaker Minimum 10 Watts Rms To Deliver Full Range Sound 20Hz-20Khz Input Power Supply-As Per Indian Standard With Compatible Power Cable & Connector Accessories-All Device Driver And Cables For Connecting With Computer, Remote Projector Should Be Supplied With Full Function Remote Control Having A Laser Pointer Inbuilt In The Remote Control Other Accessories -Cables (Of 5 Meter Length Hdmi, Power) Should Be Supplied Along With Projector, Bis Registration Quoted Model Of Projector Should Have Valid Bis Registrationmake : Sony , Dlp Projector ,Brightness-4200 Ansi Lumens Or Better, Native Resolution-Wxga (1280X800) Or Higher, .Throw Short Throw, Keystone & Corner Correction-Projector Should Have Both Vertical (± 20º) And Horizontal (± 20º) Keystone Correction And Four Corner Adjustment. Minimum Lamp Life-15000 Hrs In Normal Mode, 20000 Hours In Economy Mode Input Ports-Hdmi -2 ,Vga - 2, Audio In, Video X 1, Other Ports-Rs 232, Lan(Rj 45),Usb Type A For Charging, Output Vga, Audio Out, Contrast Ratio-22000:1 Or Better, Throw Ratio-0.49 Or Better Throw Distance 0.63M-1.9M (100 @ 1.06M), Digital Zoom-0.8X-2.0X, Aspect Ratio-16:10 In Built Speaker Minimum 10 Watts Rms To Deliver Full Range Sound 20Hz-20Khz Input Power Supply-As Per Indian Standard With Compatible Power Cable & Connector Accessories-All Device Driver And Cables For Connecting With Computer, Remote Projector Should Be Supplied With Full Function Remote Control Having A Laser Pointer Inbuilt In The Remote Control Other Accessories -Cables (Of 5 Meter Length Hdmi, Power) Should Be Supplied Along With Projector, Bis Registration Quoted Model Of Projector Should Have Valid Bis Registrationmake : Optima , Interactive Board: Technology Infrared(Ir) Or Better, Resolution 30000*30000 Or Better, Touch Input Finger & Stylus, Accuracy 1Mm Or Better, Surface Ceramic, Interface Usb, Multi-Touch Minimum 6 Points Touch, Os Driver Support Windows 10 Andlinux, Operation Temperature 0-45?, Active Area Diagonal Size (Inches) Minimum 80 Inches Diagonal, Hot Keys On Both Sides Of The Boards With Description Of Icons With Single Touch Feature Access Consisting Of Calibration, Page Up, Page Down,Mode Switch, Black Pen, Blue Pen, Red Pen, Highlighter, Smart Brush, Eraser, Undo, Clear Screen, Text, Insert, Scree Recorder, Keyboard And Camera, Screen Mirroring Data From Mini Pcshould Beshared Wirelessly On Multiple Phones/Tablets Without Any Other Hardware Requirement.Accessories- Usb Interface Cable, Stylus Holder With 2 Stylus. , Photo Copier Machine Functions: Print | Scan | Copy | Fax Technology: Laser Color Output: Color Connectivity: Wireless(Wi-Fi) Usage: For Office Paper Size:A3 Print Speed: Upto 30 Pages/Min Print Volume(Per Month):Upto 5000 Ppm Features: Duplex Printing Scanner Type: Flatbed Scanner Make: Canon , Photo Copier Machine Functions: Print | Scan | Copy | Fax Technology: Laser Color Output: Color Connectivity: Wireless(Wi-Fi) Usage: For Office Paper Size:A3 Print Speed: Upto 30 Pages/Min Print Volume(Per Month):Upto 5000 Ppm Features: Duplex Printing Scanner Type: Flatbed Scanner Make: Xerox , Photo Copier Machine Functions: Print | Scan | Copy | Fax Technology: Laser Color Output: Color Connectivity: Wireless(Wi-Fi) Usage: For Office Paper Size:A3 Print Speed: Upto 30 Pages/Min Print Volume(Per Month):Upto 5000 Ppm Features: Duplex Printing Scanner Type: Flatbed Scanner Make: Ricoh , Photo Copier Machine With Dadf - Digital Photocopiermultifunctional Laser Beam Technology25ppm, A3 Size,Memory: 256Mb Ram,Print, Scan, Copy, Networking Cassette: 2, Bypass Tray: 1 Touchscreen,Scan To Email, Scan To Folder,Secured Print, Page Composerdriver: Ufriirotate Collate: Yeszoom: 25% - 400%Duplex Print: Yes Duplex Scan: Yes Toner Yiled: 14000 Print/Copy Drum Yield: 132000 Print/Copymake: Canon , Photo Copier Machine With Dadf - Digital Photocopiermultifunctional Laser Beam Technology25ppm, A3 Size,Memory: 256Mb Ram,Print, Scan, Copy, Networking Cassette: 2, Bypass Tray: 1 Touchscreen,Scan To Email, Scan To Folder,Secured Print, Page Composerdriver: Ufriirotate Collate: Yeszoom: 25% - 400%Duplex Print: Yes Duplex Scan: Yes Toner Yiled: 14000 Print/Copy Drum Yield: 132000 Print/Copymake:Xerox , Photo Copier Machine With Dadf - Digital Photocopiermultifunctional Laser Beam Technology25ppm, A3 Size,Memory: 256Mb Ram,Print, Scan, Copy, Networking Cassette: 2, Bypass Tray: 1 Touchscreen,Scan To Email, Scan To Folder,Secured Print, Page Composerdriver: Ufriirotate Collate: Yeszoom: 25% - 400%Duplex Print: Yes Duplex Scan: Yes Toner Yiled: 14000 Print/Copy Drum Yield: 132000 Print/Copymake: Ricoh , Photocopier Machine With Dadf: Speed: 30Ppm, Max. Size A3 Print, Colour Scan, Copy, A3 Monochrome Lazer, Multif8unctiona, Wifi: Yes, Networking: Yes, Mobile Printing, Printer Driver Ufrii, Mono Component, On Demand Fixing, Remote Operating Software Kit, Memory 2Gb, Cassette 2 (550+550 Sheet), Bupass Tray: 1 (100 Sheet), Operation Panel: Screen Touch, Duplex Print, Duplex Scan, Scan To Folder, Scan To Email, Scan To Usb, Remote User Interface, Toner Yield: 30000 (A4 With 6% Coverage)Make: Canon , Photocopier Machine With Dadf: Speed: 30Ppm, Max. Size A3 Print, Colour Scan, Copy, A3 Monochrome Lazer, Multif8unctiona, Wifi: Yes, Networking: Yes, Mobile Printing, Printer Driver Ufrii, Mono Component, On Demand Fixing, Remote Operating Software Kit, Memory 2Gb, Cassette 2 (550+550 Sheet), Bupass Tray: 1 (100 Sheet), Operation Panel: Screen Touch, Duplex Print, Duplex Scan, Scan To Folder, Scan To Email, Scan To Usb, Remote User Interface, Toner Yield: 30000 (A4 With 6% Coverage)Make: Xerox , Photocopier Machine With Dadf: Speed: 30Ppm, Max. Size A3 Print, Colour Scan, Copy, A3 Monochrome Lazer, Multif8unctiona, Wifi: Yes, Networking: Yes, Mobile Printing, Printer Driver Ufrii, Mono Component, On Demand Fixing, Remote Operating Software Kit, Memory 2Gb, Cassette 2 (550+550 Sheet), Bupass Tray: 1 (100 Sheet), Operation Panel: Screen Touch, Duplex Print, Duplex Scan, Scan To Folder, Scan To Email, Scan To Usb, Remote User Interface, Toner Yield: 30000 (A4 With 6% Coverage)Make: Ricoh , Sports & Physical Education , Vertical Plate Tree Make : Cosco - Series Ctb 54/ , Vertical Plate Tree Make : Viva-If Pto / , Vertical Plate Tree Make : Aerofit- Af2401 , Olympic Flat/Incline/Decline Bench Make: Cosco - Series Ctb 86/ , Olympic Flat/Incline/Decline Bench Make: Aerofit-Af 2932/ , Olympic Flat/Incline/Decline Bench Make: Viva-Hs 026 , Beauty Dumbbell Make: Cosco - Series Ctb 67/ , Beauty Dumbbell Make: Aerofit-Af7236 , Beauty Dumbbell Make: Viva-Kh 305 , Utility Bench, Make: Cosco- Series Ctb 38/ , Utility Bench:Make : Viva-It 7022/ , Utility Bench, : Make: Or Any Other Compatible Brand , Rod Stand Make: Cosco- Series Xrs 9/ , Rod Stand: Make: Aerofit-Af 7222/ , Rod Stand: Make: Viva-Kh304 , Viva Pro Tpu Solid Dumbells(Made From Pure Plyurethane) /Ialpha Rubber Coated Bouncer Dumbbell / Any Other Compatible Brand , 2.5 Kgs. , 05 Kgs , 7.5 Kgs , 10 Kgs , 12.5 Kgs , 15 Kgs , 17.5 Kgs , 20 Kgs , Weight Plates: Viva Force Solid Olympic Plates (High Grade Virgin Rubber) / Usi Universal Cross Grip Olympic Weight Plate Rubber / Leeway Rubber Weight Plate; Gym Weight Plates , 2.5 Kgs. , 05 Kgs , 7.5 Kgs , 10 Kgs , 15 Kgs , 20 Kgs , 25 Kgs , Olympic Barbell: Straight Olympic Barbell Rod Heavy Weight Lifting Training Gym Fitness Workout (30 Mm Internal Dia & 50Mm Outer Dia) With Two Springs Sides Locks, Chrome With Proper Knurling , 4 Feet , 5 Feet , 7 Feet , Olympic Bar: Ez Olympic Curl Barbell Bar Solid Steel Professional Bar With 2 Locks (Diameter 28Mm Sleeves Diameters 50Mm, Size 4 Feet) , Rubber Tile (Floor): Size : 500 Mm X 500 Mm Thickness :10 Mm Recycled Rubber Crumb-10 Mesh, Shock Absorbent, Antiskid Colour : Gray & Black (Sq. Feet)
Contract Date : 01 Aug, 2022   |   Contract Value : 59.91 Lakhs
BRR : 9545191 Tender For Provision Of Solar Power Plant At Sevoke Mil Station Under Ge Sevoke Road.; 2 Design, procurement, erection, installation, testing and commisioning including connecting to local utility grid; Grid connected solar photovoltaic plant 0.8 MW output peak capacity with net billing arrangement including Solar Photovoltaic Modules,DC Cabling, Module Mounting Structures (suitable for ground mountingwith and including Soil Investigation as per OEM recommendation, RCC foundation framed structure and other connected civil work duly vetted by IIT / NIT), Array Combining Boxes, ACDB, DCDB, Lightining Protection of SPV modules and other accessories, String Inverter as Power Conditioning Unit, Weather Station and Data Monitoring system (SCADA) all as per detailed specifications given in tender documents, latest MNRE/SECI/NISE/IREDA guidelines and directions, meeting the Make in India (DCR), consisting of all requisite accessories (BOS-Balance of system) and including the following main components (NOTE : The work shall be executed directly by OEM only through contractor.) Item Continued as 1.01 to 1.45 3 (A) Photo Voltaic Module: Mono-crystalline Silicon Bifacial Solar Photovoltaic Modules of minimum 550 Wp(module power and number of modules to be selected according to available area), having cell efficiency more than 20% under standard conditions, form fill factor more than 0.76, plant performance ratio > 75%, made of high transmitivity glass front surface and it shall give high encapsulation gain (transmittance above 90% and bending less than 0.3%). The modules shall have the following features :(a) The electrical parameters of SPV modules under standard test condition of irradiance 1000W/sqm, AM 1.5 Spectrum and temp 25 degree Celsius shall be as under : (i) Max Peak Power Pmax : 550 Wp or more (ii) Voltage at Max Power : > 40 V (iii) Current at Pmax :> 10A 4 (iv) Short Circuit Current :> 12A (v) Open Circuit Voltage :> 47 V (vi) Module Efficiency : > 20%(b) Rated output of the modules shall have positive tolerance of 3-5% and no negative tolerance is allowed.(c) It shall perform satisfactorily in RH 85% with temperature up to +85 degree C and should withstand wind of 200 kmph on the surface of panel.(d) PV modules shall be warranted for their output peak watt capacity, and it shall not fall of its initialvalue below 90% in first 10 year end and 80% after the end of 25 years.(e) Each module shall have RFID tag encapsulated with solar cell bearing following details (i) Name of Manufacturer of SPV Module (ii) Name of Manufacturer of Solar Cell 5 (iii) Month and year of Manufacturing (separately for cell and module) (iv) Country of Origin (both cell and module) (v) Peak wattage, Im, Vm and fill factor of the module (vi) Date of year of obtaining IEC PV module qualification certificate including the test lab issuing IEC certificate. (vii) Unique serial no of model no of module (viii) IV curve of module(ix) Other relevant information on traceability of solar cells & modules(f) The temperature coefficient of power for the module shall not be more than 0.50% per degree Celsius.(g) The module must have bypass diode of suitable capacity.(h) PV module must confirm to latest edition of IEC 61215/ IS 14286. In addition the modules must confirm to IEC 61730 Part I and II for construction and testing & safety qualifications and confirming to IEC 62804 PID.(j) It shall also be in conformity to latest minimum technical specification issued by MNRE/IREDA/SECI/NISE/ALMM from time to time. Modules should be of MNRE/IREDA/SECI/NISE/ALMM approved companies and as per latest IEC/IS standards. 6 (k) RFID reader is to be provided by contractor(l) Both PV cells and SPV modules shall be made in India (DCR).(m) Each structure should have angle of inclination as per the site conditions to generate maximum power. However, to accommodate more capacity the angle inclination may be reduced to 10 - 13 Degree until the plant meets the specified performance ratio requirements.(n) Fire Points with Fire extinguisher liquefied CO2 gas of capacity 10 kg and adequate qty confirming to relevant IS or ISI mark complete as recommended by manufacturer deemed to be included in the unit rate quoted.(o) Danger Board and Rubber mat as recommended by manufacturer deemed to be included in the unit rate quoted.(p) S&F Pressure Booster pump electrically operated with minimum 3 HP 02 Nos (Running+ standby) three Phase AC Supply motor and having head not less than 20 mtr, including PCC foundation civil wokrs and necessary cable required for connection in drawn in PVC conduit heavy duty/ DWC/Electrode pipe from existing nearest point to the motor starter panel including motor starter suitable capacity,PP-R IS-15801 (Polypropylene random co-polymer) pipe 3-layer 63 mm/50 mm/32 mm/25 mm inner dia (outer green coloured UV stablilized, middle black coloured UV stabilized and innermost layer white coloured with anti-microbial property) fusion welded grade PN-10 SDR-11 ( Pressure nominal 10KGS/cm2 ) having thermal stability for hot & cold water supply including all types of plain and brass threaded PPR fittings of any size such as elbow, tees, FTA and MTA etc laid in trenches with necessary exavation, removing and returning filling work and including all accessories from the new PVC tank cap 10000 Ltrs install at proposed site for cleaning of entire solar power plant system.(q) SPV Panel is to be fixed in such a way that lower portion of the Panel remains atleast above 1.5 mtr of finished reflecting surface and cost deemed to be included in the quoted rates. 7 (B) Junction Boxes: Junction boxes of suitable Nos (as per design)/OEM recommendations inputs and suitably rated out put having separate DCfuses for both (+)&(-) on input and isolator on output terminal for each string.Each junction box must have as pare input terminal.The junction boxes shall be dust and vermin proof and water proof made of FRP/ Thermo Plast with IP 65 protection in compliance with IEC 62208 and shall be UV resistant, fire retardant. It shall have surge protection and maintenance free earthing as per relevant standard. The junction box shall have suitable arrangement of the following: (a) The strings are required to be connected to the copper bus bar through individual fuses. (b) Provide arrangement for disconnection (DC dis-connection switch) for each SJB/ SCB. (c) To provide a test point for each sub group for quick fault location and to provide group array isolation. (d) Each array box shall be of relevant IEC standard. (e) Each array junction box shall have suitable bypass & reverse blocking diodes for minimum DC blocking voltage of 1000V with suitable arrangement of its connection. Reverse blocking and bypass diodes shall work for extreme temperatures and shall have efficiency of 99.98% confirmed by appropriate IEC standard. 8 (C) DC Cables: Suitable size of XLPE insulated tinned Copper cable (min 10 sqmm) of solar grade, 1100 Volts and UV resistant for outdoor installations confirming to IEC : 60227/15694 & 60502/ IS : 1554 (Pt I&II)) and shall be as under : (a) All cables and connectors must be as per IS/IEC standards and shall be able to withstand harsh environmental conditions including high temperature, UV radiations, rain, dirt, burial and attack by moss and microbes for 25 years and voltage as per latest IEC/IS. (b) All the cables / wires shall be provided with UV resistant printed ferrules for DC wires. (c) The size of the cable shall be such that average voltage drop at full power from PV module to inverter shall be less than 1.5%. (d) Cable batch No., Drum No, IS code and size and make shall be mentioned on every one meter or as per OEM practice. (e) The wiring of the module interconnection shall be in UPVC/HDPE pipe of suitable size. (f) The cost of interconnecting DC Copper cable, MS cable trays, MS cable trays suitable to accommodate Solar grade cables from SPV module to inverter are included in the item. 9 (g) Boring of holes under road, pavement, hard standing by trenchless technology (HDD) GI protection pipe up to 100 mm bore (dia), maximum 2.5 metre below of apron areain ant type of soilcomplete.Note : (i) All the precaution to be taken by the contractor before drilling the bore. The contractor has to take plan of existing cables any type and pipe line in existing area before drilling the bore. (ii) Any damage to existing cables any type and pipe line in the way of drilling the bore will be repaired and make good by the contractor within 24 hours. No extra cost will be paid in this account. (iii) Contractor has to get the survey of route, length and depth for boring before quoting the rate. (iv) Connected items like HDPE/PPR/DWCPE pipes, exavation, removing, return filing, channel, any type of metal work is not measured and paid separately under relevant items.(D) Module Mounting Structure (MMS) (Suitable for ground mounting on any type of soil condition) :Design, procure, fixing, support structure made of hot dipped galvanised steel with min 85 micron thickness including necessary PCC / RCC foundation and associated work (cutting, grounding, PCC filling, disposing waste material,etc., complete) and fixing mounting arrangement suitable for SPV modules so as it can with stand wind speed of 170 km per hour & minimum yield strength off 250 MPa. The mounting structure is to be installed on ground. Mounting structures to be so designed that maximum load is directly on ground. It shall also observe minimum space without sacrificing the out put of SPV panels & adequate spacing between the arrays shall be available for easy cleaning and maintenance. Nuts, bolts, protected from the atmosphere and weather mounting structure shall have to be adequately of Stainless Steel of grade SS316. 10 NOTES :- (a) Two numbers of anti theft fasteners of Stainless Steel on two diagonally opposite corners of each module shall be provided. (b) Module mounting structure shall be fitted to provide maximum generation. (c) MMS design shall be supported with Staddpro Report vetted by Third Party (Gov Institute) and submitted for the approval of the Accepting Officer. (d) The height of approved design MMS for solar power plant shall be as per latest MNRE/IREDA/SECI/ NISE guidelines. (e)Minimum grade of RCC M-25, design mix (using 20mm graded crushed stone aggregate includingTMT bar as per design, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete and other connected works as per design and OEM recommendation. Civil work shall be designed through approved consultant of MES as per latest MNRE/IREDA/SECI/ NISE guidelines and vetted by IIT / NIT.(E) Lightning Protection forentire Solar Power Plant (i.e PV Array, Inverter etc) : Design, procure and fix lighting arrestor system confirming toIS/ IEC-62305(Part1-4)on the ground. The air terminal shall be fixed at the top of MS pole with base so as to beat least two meter above the pole to be protected. Its height above 9 mtr level shall be depend upon the level of protection and protection radii required. 11 NOTES :-(i) The cost of all equipments, MS Pole, Copper strip upto earth test point,LA, etc., shall be deemed to be included in this item. (ii) The cost of sufficient earthing for lightning protection is also included in this item to be provided by Engr-in-charge. and no extra payment will be made to the contractor on this account (iii) The complete system shall include chemical earthing (as per OEM recommendations) and earth strip/cable etc for earth of SPV module, array, inverter,DC & AC boxes and for LA etc as per latest IS/MNRE/IREDA/NISE/SECI/ALMM specifications and guidelines.No separate cost of the same is included in the schedule and amount will be paid to the contractor on this account. In case of any dispute, decision of Engr in charge will be final, conclusive and binding to contractor. (The earthing shall be of copper earth plate and having specification as per SSR Item Sr 19474). Earth resistance shall not be more than 3 Ohms. (iv)Separate LA arrangement & the design document of the same shall also be submitted. (v) The protection against induced high voltage shall be provided by the use of metal oxide varistors and suitable earthing such that induced transient find and alternate route to earth. (vI) SPV Power Plant shall be provided with lightening and over voltage protection. (vii) Internal surge protection shall consist of three MOV type surge-arrestors connected from +ve abd +ve terminals to earth (via Y arrangement) 12 (F)Power Conditioning Unit: Procure, fixing, testing and commissioning of minimum 4 (Four) unitswith overall not less than 800 KW output on 11 KV AC supply, Solar-power inverter suitable for without DC power of Solar PV module/ array with AC output further feeding to grid confirming to IEC:61683 for efficiency, IEC:62109-1 or equivalent for safety and IEC:62093 for reliability. The input DC & output AC technical specification of Inverter are as under :Input (DC) (a) Max Absolute DC input Voltage : 1000 V (b) Start-up DC input voltage : 200 - 500 V (Default 420V) (c) Operating input DC voltage range : 200 - 1000 V (d) No of independent MPPT : One (e) MPPT input DC voltage range at Pacr : 180 - 1000 V DC (f) Max input DC Current : As per design. (g) AC grid connection type : 3Phase (4W + PE) (h) AC output power : As per design. (j) Max AC output Apperant power : As per design. (k) Max AC output Current : As per design. (l) Max AC fault current : As per design. 13 (m) Nominal Output Voltage : 800 Volts AC 3phase or as per the design of Solar Stepup Transformer (n) Output voltage range :± 10% (o) Output Frequency : 50 Hz ± 3Hz (p) Power factor : > 0.99 (q) Harmonic Distortion Current : < 3% (r) Efficiency : > 98% (s) Standby operation consumption : < 1.5 W(t) Operating temperature upto 85 degree centigrade (u) The Copper based inverter shall have minimum IP-67 protection, ground fault monitoring, reverse polarity protection, anti-islanding, DC reverse polarity, AC and DC short circuit current and over current, AC and DC over voltage and over temperature. 14 (v) The inverter shall adjust voltage and frequency levels to suit the grid. (w) The inverter shall be self commulated with Pulse Width Modulation (PWM) technology and shall be capable of synchronise maximum with in one min. (x) Maximum Power Point Tracker (MPPT) confirming to IEC 62093 shall be integrated in the inverter to maximise the energy drawn from the PV array (y) Monolithic design of inverter is not permitted. (z) Shall have anti-Islanding features. (aa) The inverter shall have suitble nos of protected inputs (asper design) and outgoing shall be protected by ACB/MCCB. (ab) The inverter should have MODBUS, PROFIBUS, ETHERNET common ports. (ac)The inverte rshall include appropriate self protection and self diagnostic features to protect itself and the PV array fromthedamageintheeventof invertercomponent failureor fromparametersbeyondtheinverterssafeoperatingduetointernaland/orexternalcauses. Invertershallhaveprotectionarrangementagainst ground leakage faults, over voltage, (SPD) & over current. Inverter shall have arrangement for adjustment for adjusting DC input current and shall trip against sustainable fault down stream and shall not restart till fault is rectified. (ad) The inverter should have provisions of Galvanic isolation, anti-islanding protection (IEEE 1547/UL 1741) equivalent IS and lightening. (ae) PCU must have the feature to work in tandem with other similar PCUs and be able to be successively switched ON and OFF automatically based on solar radiation variations during the day. (af) Minimum Warranty of Inverter- 12(Twelve) Years and defect liability period deemed to amended accordingly for the said item. 15 (G)ACDB : Outdoor type powder coated weather proof,vermin proof made out of CRCA sheet front open able door, lockingarrangement, including suitable working space in DCDB busbar chamber, cable box chamber including Copper busbar of designed capacity /bus raisers suitable capacities with PVC sleeves/tape RYB colour for phases identification, including all bus raiser shall be extend upto cable box chamber fixed on fibre insulation for RYB & neutral to all out going cable, confirming to IP-65 and fixed on wall / floor with control wiring with comprising cable gland brass, copper lugs etc. and comprising the following as per design :- (i) MCCB 4Pmicroprocessor based for outgoing (ii) MCCB 4Pmicroprocessor based for incoming (iii) AC type 2 Surge Protection Device (iv) Spreader Terminals as per requirement (v) Multifunction meter (vi) CT of suitable ratio(vii) Copper busbar chamber (ix) The earthing shall be of copper earth plate and having specification as per SSR Item Sr 19474).Earth resistance shall not be more than 3 Ohms. 16 (H) DCDB:- Outdoor type powder coated, weather proof, dust proof,vermin proof made out in CRCA sheet front open able door, looking arrangement, including suitable working space in DCDB busbar chamber,cable box chamber including copper bus raisers with PVC sleeves/ tape RYB coloursfor phase identification, including all bus raiser shall be extend upto cable box chamber, confirming to IP-65 and fixed on wall /floor with contral wiring with comprising cable gland brass, copper lugs etc. (i) MCCB as per requirement (ii) Fuse as per requirement (iii) Copper busbar chamber. (I) Weather Monitoring System Pyranometer : The pyranometer (ISO 9060 classification ) alongwith necessary assessories for measuring incidental solar radiation at horizontal and inclined plane of array. Specifications of the pyranometer shall be as follows :- (i) Spectral response : 031 to 2.8 micron,(ii) Time response (95%). Max 15 second 17 (iii)Nonlinearity + 0.5% (iv) Temperature response : - 2%(v) Tilt error <+/- 0.5% (vi)Zero offset themal radiation +7W/Sqm (vii) Zero offset temperature change + 2 W/Sqm(viii) Operating temperature range - O °C to 80°C(ix) Non stabillity Maximum - 0.8%,(x) Resolution minimum +/-1 W/Sqm (xi)Output Analog 4.50mA (xii) Digital RS 485(xiii) The earthing shall be of copper earth plate and having specification as per SSR Item Sr 19474).Earth resistance shall not be more than 3 Ohms. 18 (J)Balance of System(BOS) Items/ Components:TheBOSitems/componentsof theSPVpowerplants/systems deployed under this project shall conform to the latest edition with certificate of IEC or equivalent BIS Standards/MNRE specifications/ as specified in Para 1.01 of Minimal Technical Requirements/ Standards for SPV System/Plants to be deployed during this financial year under the programmes of MNRE available on MNRE website as on last date of quoting of tender. Notes:(i) The contractor must visit the site before quoting the rates for this item to assess the site condition so as to decide up on location and layout of SPV, placement of inverter, length of DC cables, lightning arresters, etc., complete. (ii) The contractor shall submit complete scheme including electrical diagram of the work, schematic diagram, SPV module layout, placement of LAs, Civil work, etc., complete as per IREDA/ SECI/NISE/MNRE/ALMM latest guidelines as applicable, Relevant IEC/IS norms to the GE for approval with in one month of date of commencement of the work. (iii) The rate quoted is deemed to be inclusive of the all protection system including surge, lightning arresters and necessary earthing all as specified and directed. 19 (K) Remote monitoring system (SCADA) for solar power plant complete with all electronic andelectricial partswith andincluding all necessary software and hardware etc to make fully functional connected to LED monitor (55 inches) with complete plant parameters as required and operate the system from remote and Other Accessories includingandThe system will be controlled from the main control room where all the data from different parts of the plant shallbe received, analyzed and action taken either manually or on auto as per the system design by OEM . The SCADA shallhave remote monitoring capability comprising with the following Items and with and including all connectedaccessories as per OEM recommendation complete:(a) Main SCADA control wall mounting panel complete with fixing arragnment like nut bolt, washers suitable size and connected items. (b) LED Moniter (55. inches) with mouse, key board, CPU (Minimum 1 TB storage alongwith 12 GB RAM, i7 processor), key pad and single phaseUPS 10 KVA with 12 Volt battery, 14400 Ah battery bank with rack and required battery backup should not be less than 4 Hrs inside control room.(c)“SCADA System shall be audited for Cyber Security by CERT certified firms at the time of commissioning. Subsequent cyber security audit shall be carried out after every 03 years and cost of audit and rectification shall be born by the contractor” 20 The Contractor shall provide following defined user access levels, unless otherwise instructed by the Engineer-in-Charge: -• Normal viewing only (default level) The default level shallpermit users to view al displays except those specifically assigned to a higher level of access.• Dally Access The daily access level shall allow viewing (ie default an printing at trend displays.• Operator Level (Remote Control) The operator level shall permit authorised users to access lower levels a and to carry out the following actions:- Perform control actions Acknowledge alarmsEnter or modify manually-entered data for inclusion in thereports.• Monthly and Yearly Data Archiving The level shall permit authorised users to access lower levels and shall provide the facility to download specific data to long ten data storage for archive purposes(d)The SCADA software shall be of a proven design and reliable, and conforming to industrial standards and shall: -• Support multiple makes of RTU/ Microprocessor controller/ transmitters and models and provide required software features needed to easily adapt a device whichshall not be supported as standard to the SCADA system. 21 • RTU/ PLC/ Microprocessor base controllers and transmitters shall have an expandable architecture and scalability to provide future capacity increases in SCADA system as well as meet present needs of the administration, provide multi-level security and password mechanisms to prevent use of the system by unauthorised persons. The access privilege of authorised users shall be defined separately and permission shall be provided to the users only to access areas concerning them, provide an on-line operatingenvironment.• Adding a new RTUI Microprocessor based Controller to the SCADA system or changing configuration of the existing RTUs/ Microprocessor based controller shall not result in stopping or hinder working order of SCADA system.• The Contractor shall specify maximum number of data which shall be achieved by the system without any performance loss. The Contractor shall conduct necessary tests to prove maximum number of data points achieved. The Contractor shall also be responsible to create additional data points necessary for conducting such tests. Any AutoCAD graphics shall be able to be converted to process diagrams and shall be re-loaded and operated after completion of all works and during tests.(e)The Contractor shall hand over to MES the SCADA and application software (as CDs or DVDs) necessary for re-loading software to the system in case of failures The CDs or DVDs shall be provided after making the necessary tests. The operating system ofrouters and work stations shall be of an architecture that provides a multi-tasking operating environment, and SCADA software shall also be multi-tasking. Therefore multiple tasks such as receiving measurement results from devices, displaying these results on computer screen. storing on a computer disk, sensing alarm conditions that may occur based on measurement results, and displaying them to users, generating reports from collected data, and printing them cut, transferring issued commands to Microprocessor controllers/ RTUs/ PLC, that SCADA software is supposed to execute shall be handled simultaneously without one task waiting for another. 22 To configureSCADA software or to change the system configuration, definitions shall be either defined directly by using a keyboard or another interactive tool or mechanisms that allow importing of configuration definitions from a text file created with a text editor. The database configuration shall be provided by means of an interactive program that contains menus or similar approaches and shall be easy to use The database configuration definition program, when required, shall be capable of extracting definitions related to the configuration from information created in text format to use as definitions for configuration The following shall be possible online without interruption or hindering of usual operations: -•Adding an RTU to the SCADA system.•Deleting an RTU from the SCADA system•Changing configuration information related to an existing RTU definition.•Modifying definitions in database containing information about measurement and control points.•Creating screen pictures which offer operators to monitor and control the SCADA system.•Similar configuration changes. 23 (f)SCADA software shall be upgradeable to new versions with an automatic mechanism to be provided by the Contractor. The old version of software shall be overwritten by new version without resulting in a change in any of the definitions created in previous version, nor disturbing the operational logic defined in previous version. Al! text being available on the screen shall be in English language The database shall be configured on-line when the SCADA system shall be in operation. The changes on existing definitions or new definitions related to database shall be made when the data collection n and control functions are being performed. The SCADA Software shall be operated using the database that shall be resident in the memory(g)Data Exchange The control system shall provide a method of real-time data exchange with different application programs like Geo Information System (GIS). relational database, third party spreadsheet packages, report generation and graphical simulation packages.(h) Historical Data Management An historical data management (HDM) system shall be provided for archive, storage and retrieval of operational data comprising field input data, manually-entered data and calculated points Archived historical data shall minimally include averages, minima and maxima for each analogue value compiled over hourly. daily and monthly time periods, with a minimum capacity of 1o00 points. The HDM system shall be capable of selectively increasing the rate of data capture based on events, such as process variable status, discrete inputs, or operator command. Minimum and-maximum data shall include the time and date of occurrence. Gaps in collected data caused by faulty instruments or control system equipment shall not be included in average). minimum and maximum compilations. 24 (j) Report GenerationThe system shall be provided with a report generator utility which shall enable authorised users to create, delete or modify report definitions The report definitions shall allow for retrieval of data from on-line database and farm historical data files and for formatting data for output to printer. The format of each report shall be definable by user to include the definition of static or background data, placement of data base values, number of significant digits of a value, date and time of report and calculated values(k)Graphic Display GenerationThe system shall be provided with an interactive on-screen graphic generation utility which shall allow an authorised user to create new graphic displays and modify or delete existing displays at any work station including those associated with the LCP/ outstations. The generation utility shall include an interactive linkage process allowing user to link symbolic, numeric and bar graph representations and data entry locations to dynamic data base variables. The graphic display system shall be capable of making full use of the VDU resolution in the composition and display of graphic information. Graphic symbols shall be definable by the user for display of static and dynamic data. The user shall be able to as5emble a library of symbols which shall be retrievable into any graphic display. Text and symbols shall be able to be enlarged, shrunk, moved, mirrored or related with reference to a given display. The system shall be able to represent dynamic analogue data on a graphic display as a variable-length, sizeable bar graph, as well as numeric text. 25 (l)DisplaysGeneral all displays, excepting those containing data derived from historical files, shall be completely displayed within two seconds of the operators request. Dynamic data shall be continuously updated while being displayed. All screen displays shall provide following displays which shall be fixed in their locations to normal operations:• Alarm banner window at bottom of the screen display showing last three highestpriority unaccepted alarms. Where the system allows contents of banner to be limited (eg by user name or group) then the selection criteria applied shall be displayed with the banner.• Main display area for user selected displays e.g. mimics, alarm lists, etc.• System dialogue banner window at bottom of the screen shall display relevant system information such as error message and user prompts 26 •A day, date and time indicator shall be able to show local time an alarm bannerarea shall be included on all displays which provide information regarding most resentalarm events. The system shall allow operator to obtain details of most recent alarm event from any operational screen display through direct operation using a maximum oftwo keystrokes or selections. The system shall allow the operator to obtain a print of any display, including graphics through use of a standard system command. Screen displays shall appear identical incorporated form Dynamic data contained on a display shall not change during screen print Such that a snapshot of conditions is portrayed. Each display shall include time of day in hoursminutes and seconds and date in day, month and year format.•A facility shall be provided which allows paging to related displays through the use of ‘page forward or backward keys, or through the use of pick points(m) Suitable size of HT & LT XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 11000 Volts and 1100 Volts grade with stranded aluminium / copper conductor of size as per OEM recommendation and approved design ISI markedincluding cable glands, lugs, jointing kit etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc.with all fixing & connecting accessories and necessary earthwork, civil work deemed to be included in quoted rates of the above items.(n)Generic Displays.The system shall produce various generic displays automatically 27 Metering arrangements: (A)Suitable bi-directional metering arrangements with recording facility shall be provided as per the norms of WBSEDCL. The metering arrangements must have feature to measure and record, (i)Parameters of KW, KWh, KVAR, voltage, current, PF and any other metering required to determine efficiency and efficacy of the system. (B) LT 3 Phase 4 Wire Electronic Tri vector Meter with CT ratioshould be as per capacity of SPV plant. (i) Standard: IS 13779:1999 / CBIP 88 (ii) Accuracy: Class 0.5 (ii) The metering arrangement shall have inbuilt Solar PV Plant synchronisation features. (iii) Reference Voltage - 3x240 V (iv) Basic Current (Ib)- 5 A (v) Maximum continuous current (Imax) - 10 A (vi) Rated Frequency (variation) - 50Hz (±5%) 28 (vii) Power consumption:- Voltage circuit: Less than 1.5 W and 10 VA per Phase at reference voltage, reference temperature and reference frequency Current circuit: Less than 1 VA per phase at basic current, reference frequency and reference temperature (viii) Display type: 8 digit 7 segment backlit LCD display, not less than10 mm character height (ix) Display in the event of Power Failure: Internal battery back-up for LCD display (x)Communication port: Galvanically isolated Optical Communication port for data transfer through either CMRI or remote device or both is providedwith RS 485 for DLMS protocol (C) CT/PT operatedenergy meter with following features (i) True four quadrant metering (iii) Time and day metering with maximum demand registration and automatic billing (iv) LCD display with announciators for various critical events (v) Scroll lock feature for continuous display of a desired parameter on display (vi) High resolution energy display mode for dial test (vii) DLMS protocol for meter reading, with option to remote reading port. 29 (viii) Advanced event detection features for voltage, current and magnetic influence (ix) Meter reading in absence of mains, using internal battery. (x)Power Manager Device Nano type with 4 inverter support with energy monitoring, zero export control, Load Management having RS-485 communication port, ethernet including RS 485 cable core size 0.5-1.5 Sqmm to establish communication between inverters, SCADA and sensor as per OEM recommendation with and including all connectedaccessoriesdeemed to be included quoted rates.(xi) Digital WIND SPEED SENSOR withminimum 3 cup Anemometer range 0 to 70 Mtr/ Sec distance constant 2.5 Mtrs output TTL Pulses output proportional to wind speed and diameter of cup 50mm with brass housing and stainless stell shaft(xii) WIND DIRECTIONSENSOR with wind vane and sensing vain coupledto linear endlsess potentio meter IP 67, range 0-357degrees, operating temperature -40 to +60 degrees celsiuswith brass housing and stainless stell shaft and aluminium vane complete 30 (xiii) AIR TEMPERATURE SENSOR withRTD sensing element PT100 mounted inside a weather shield duly coated with weather proof reflective white paint , range -40 degree to +60 degree celsius with nylon body housingwith weather shield and brass stem to mount the sensor, includingpower requirment 5 Volt DC complete. (xiv) MODULE TEMPERATURE SENSOR Model PT 1000 measuring range -40 Degreeto + 80 Degree Celcius with suitable ouput as required and directed on site and mounting on RTD encapsulated in suitable housing including connecting cables as required complete.(xv)Tipping Bucket Rain Gauge with Magnet and Red Switch type Sensing, rim diameter 203 mm and collecting are 335 MM SQ, Rain gauge shell made up of FRP bucket and mounting made up of stainless steel SS316 and unlimted capacity,including connecting cables as required complete.(xvi)SOLAR Radition Sensor ARN 8101 with 72 element thermo pile sensor and spectral range 0.3 to 3 Micro Mtrs and sensitivity 20 Micro Volt/ W/M², range 0 to 1500W/SQM & output 0 to 25 milli Volt and operating temp -10 to 70 Degree Celsiusincluding connecting cables as required complete with all fixing arrangment and necessary civil work complete with including all connectedaccessories as per OEM recommendation/Designcomplete: 31 (L)Step up solar transformer (800 volt/11 KV)” - Design,procure,erection, installation, testing and commisioning including connecting to local utility grid :Oil filled Type 3 phase, 50 Hz, ONAN cooling type, vector group of appropriatetype, number of load voltage Ratio: number of Phases / Freq.: 3 Phase / 50 Hz., Sealed type Copper wound Transformer with Off Load Tap Changing Arrangement on HV side in steps of 2.5% , +5% to -10% having cable end boxes on HV side suitable for 3 Crore X 300 Sq. mm. XLPE cable of 11 kV grade on HT side and LV side complete with all accessories like buchholz relay, Oil temperature indication, winding temperature indication and alarm etc preferbly DMCR Protection Relay i/c first filling of filtered dehydrated K Class natural Ester Oil bioTransol (as per IS 16659) and confirming to IS 1180 and losses shall be as energyefficiency Level 3 only & 100% load phase, with an impedence of 6.25% i/c as per specification below complete in all respects as required at site. Design ambient to be considered as 50 Deg C.All the balance parameter like temp rise, Basic insulation level, flux density etc shall be strictly in accordance with IS 1180 Part - 1 only including necessary earth work, PCC plinth foundation etc.Heat Run Test is the mandotary test for each Transformer.Standard: The equipment shall conform to the latest edition of applicable standards as follows. In case of conflict between applicable standards and this specification, this specification shall govern.• IS 2026 Standard for Oil filled Transformer• IS:3639 for Fittings and Accessories• IS:2099 for Bushings > 1000 V• IS:7421 for Bushings < 1000 V• IS:1271 for Electrical Insulation classified by Thermal stability• IEC 62770 Natural Ester Oil• CBIP Guidelines 32 (xvii) CORE : Transformer shall be double wound, core type with low loss, non-ageing, high permeability PRIMEGRADE, CRGO with M4 Grade or Better, perfectly insulated and clamped to minimize noise and vibrations. Followings should be Mandatory for any manufacturer: -(a) Transformer shall be of BOLTLESS core design.(b) Core shall be purchased Directly from Manufacturer or from their accreditedMarketingorganization of Repute & not through any agent. Bidder has to submit manufacturer’s name during bidding having sufficient credential & Core has to be purchased from the approved manufacturer.(c) Stage inspection of the core shall be done at manufacturer’s premises & inspection call shall be given with following Documents: (i) Invoice of the supplier (ii) Mill’s test certificate (iii) Packing list (iv) Bill of landing & Bill of Entry certificate by customs(d) Transformer manufacturer should have in-house core cutting facilities for proper control & monitoring of quality & to avoid mixing of Prime core with Second grade /defective core materials. Transformer Manufacturer should have in-house slitting Machine so that core is cut to width & stacked with minimum air gap thus ensuring Burr level less than 10Microns.(e) Core shall be procured from one of these reputed Manufacturers : Posco / Nippon/ Novex/ Ak Steels.(f) The insulation structure for the core to bolts and core to clamp plates shall be such as to withstand a voltage of 2000V for one minute. 33 (xviii)Tank:Tank should be of corrugated wall construction type. The exterior of tank and other steel surfaces exposed to the weather shall be thoroughly cleaned and have a priming coat of zinc chromate applied. The second coat shall be of an oil and weather-resistant nature, preferably of distinct colour from the prime and finish coats. The final coat shall be of a flossy, oil and weather resisting non-fading paint of specified shade. The interior of the tank shall be cleaned by shot blasting and painting with two coats of heat resistant and oil insoluble paint.Winding:(a) Winding shall be made with 99.9% pure electrolytic grade copper, insulated with thermally upgraded paper (Insulation Class A / Conductor Turn Insulation-Class E).The HV & LV winding should be able withstand thermal and mechanical stress in the event of short circuit.(b)Winding shall be carried in dust free area(c) The completed core and coil assembly shall be dried in vacuum and shall be immediately impregnated with oil after the drying process to ensure elimination of air and moisture within the insulation.Oil type: TransformerTransformer oil shall be as per IS-335:1993. It shall be natural/synthetic ester oil. The material safety Data Sheets (MSDS) for the Transformer oil shall be submitted by the bidder along with the offer Temperature Indicator:One set of winding temperature indicators with necessary current transformer, heating coil and a detector element and one set of oil temperature indicator with maximum reading pointer shall be mounted locally so as to be readable at a standing height from ground level. Each of the above indicators shall be provided with necessary contacts for alarm and trip: (a) Oil Insulation class : K class. It should also exhibit safety against fire hazards 34 (b) Cooling : ONAN(c) Vector Group: to be decided during design.(d) Percentage Impedance (Z%) 6.25 %.(e) Transformer Losses:as per IS 1180 - Level 1(2021)(f) Taps on HV for HV variation : +5 to -10 % in steps of 2.5% each (g) Termination (HV): Cable End box for11 KV cableof suitable size(h) Termination (LV): Cable connection(j) The transformer shall be supplied with following fittings:(k) Lifting lugs and Jack lifting pad support(l) Earthing terminals - to be decided during design. 35 (M)Earthing :The complete system shall include chemical earthing of required quantity for step-up Transformer (as per OEM recommendations) and earth strip/cable etc for earth of SPV module, array, inverter,DC & AC boxes and for LA etc as per latest IS/MNRE/IREDA/NISE/SECI/ALMM specifications and guidelines.No separate cost of the same is included in the schedule and amount will be paid to the contractor on this account in case of any dispute decision of Engr in charge will be final and binding to contractor. (The earthing shall be of copper earth plate and having specification as per SSR Item Sr 19474).Earth resistance shall not be more than 3 Ohms. 36 IMPORTANT NOTE FOR SOLAR POWER PLANT CONTRACT (COST DEEMED TO BE INCLUDED IN QUOTED RATES :-(1) The item specification and details given are for guidance purposes only and are likely to vary with modified / higher specification than that specified in the BoQ based on detailed site survey, solar potential assessment, design approval etc keeping the quantity of Solar inverter (PCU) and Solar Transformer same as in the BoQ. The items as per the finalized and approved design and specification, including make, shall be provided by the contractor without any extra cost to the department. All makes should be as per the latest MNRE approved list of makes and models.2.Cost of preparation of DPR design vetting from NISE/MNRE approved Institute and net billing arrangement (as per WBSEDCL) is deemed to be included in the quoted rate.3.The contractor shall submit complete design of Solar power plant, Schemetic/line drawings, detailed mounting structure array layout drawings alongwith SBC report based on the soil investigation as per OEM recommendation, Single line diagram with and including project reportand connected document shall be submitted by OEM through contractor prior to commencement of the work for approval of Accepting officer and subject to the drawing and designduly vetted by IIT/NIT (for mounting structure only) and vetted by NISE/ SECIfor entire scheme of Solar Power GenerationProject including evacuation and Net Metering arrangement complete before recommendation by GE for approval of the accepting Officer. 37 (i) The scope of works involves engineering, procurement & construction (EPC) of entire Solar Power Plant of capacity 0.8 MWp.4. The entire work shall be executed directly by OEMonly through contractor and contractor has to submit the MoU with OEM (agreement period for 25 years of entire Solar Power Plant Project) prior to commencement of work and same shall be approved byGE. 5. Boring of holes under road, pavement, hard standing by trenchless technology (HDD) GI protection pipe up to 100 mm bore (dia), maximum 2.5 metre below of apron areain any type of soilcomplete.Note : (i) All the precaution to be taken by the contractor before drilling the bore. The contractor has to take plan of existing cables any type and pipe line in existing area before drilling the bore. (ii) Any damage to existing cables any type and pipe line in the way of drilling the bore have to berepaired and made good by the contractor within 24 hours. No extra cost will be paid in this account. (iii) Contractor has to get the survey of route, length and depth for boring before quoting the rate. (iv) Connected items like HDPE/PPR/DWCPE pipes for entire Solar Power Plant Project, exavation, removing, return filing, channel, any type of metal work is deemed to be included in the quoted rate. 38 6.Cost of comprehensive maintenance as per OEM recommendation alongwith cost of spare parts required during 5 years of defect liabilty period after completion of Ph-I is deemed to be included in the quoted rate.7. Bidders attention is drawn to pre-bid conferance with department and also visit the site prior to bidding and other factor required as per OEM recommendation deemed to be included in quoted rates.8. The contractor has to carryout Pre-commissioning test of solar power plant including stepup transformer by CEI/SEI. The necessary tools and plants required for inspection of the plant shall be arranged by the contractor.and costsare inclusive in quoted rates.9. Contractor needs to know the irradiance of the location at the project before quoting. The contractor will design DCR (Make in India) for entire Solar Power Plant according to irradiance of the project location and efficiency of the components to produce the desired peak value as mentioned in the schedule i.e. 800 KW output on 11 KV AC supply and inject to the proposed RMU 11 KV. 10. During the execution of work any type of damage by elephant or monkey manance, contractor is fully responsible for protection of all solar power plant equipments including connected items i.e. PV Module, Inverter etc. No claim will be sought from the department. 39 11. All SCADA related activities viz. cables till SMBS and inverter and the requisite software and hardwarefor control room shall be included in the quoted rate.12. Vegetation Growth should be controlled by use of Deweeding Chemicals deemed to be included in Quoted Rates.13. Adequate Water Storage Facility of capacity 10000 Ltrs PVC Tank 5 Layer (with guarantee of 10 years after physical completion of work) on PCC Platform including suitable foundation for cleaning of PV Modules and suitable water drainage facilitiesfor both (Rain Water and Cleaning Water) from proposed site to existing drainage chamber is deemed to be included in the quoted rate.14. Solar Transformer fed from the Inverter should not be having odd harmonics (certificate needs to be required before physical completion of work).15.The Shutdown duration of Inverter should be monitored and recorded and analyzed. 40 16. The SPV Power Plant will be capable of generating 800 kW AC Output atleast once in a year and the AC Output of the plant will be not less than 90% of initial output by the end of 10 yearsand not less than 80% of the initial output by the end of 25 years.17. The Contractor shall operate and maintain Fire Protection System and safety equipments for the entire Solar Power Plant for 10 Years and cost of the spare is deemed to be included in the quoted rates.18.The firefighting system for the proposed power plant for fire protection shall be consisting of:a) Portable fire extinguishers in the control room for fire caused by electrical short circuitsb) Sand buckets in the control roomc) The installation of Fire Extinguishers should conform to TAC regulations and BIS standards. The fire extinguishers shall be provided for control room housing, PV array installation.19.Solar Components shall not be connected to LAN, WAN, or any Internal Data/OPS nw. 41 20.Sys with Bluetooth, GSM, Wi-Fi, or any Telemetry features should be avoided, unless explicitly cleared monitored.21. Finalization Of Feasibility Report, Design, Engineering, Transportation, Storage, Insurance, Civil Works, Erection, Testing & Commissioning etc., ensuring net-billing as per state net billing policy, quality control of grid connected.22.The Comprehensive Maintenance of SPV Plant would include wear, tear, overhauling, machine breakdown, insurance and replacement of defective modules, Inverters/PCU, spares, consumables & other partsas pe OEM reocmmendation and specification for 5 (Five) years under DLP of Phase-I..23.The Contractor shall arrange technical vetting of the plant during execution by the Cyber/INT officer and training by Unit Technical Pers till defect liability stage of Phase-I. 42 24.a) An energy meter (for net-billing) shall be installed between the solar Grid-tied inverter and the building distribution board to measure gross solar AC energy production (the Solar Generation Meter). The Solar Generation Meter shall be of the same accuracy class as the DISCOM service connection meter or as specified by local regulatory requirements. Separate for two different buildings.b) The bidder must take approval/NOC from the Concerned DISCOM for the connectivity, technical feasibility, and synchronization of SPV plant (if required).c) Contractor shall be provided system software (Cloud) for data hosting of Solar Power Plant with the Government approved agency and also audited by CERT-In (Computer Emergency respose team-India) is deemed to be included in the quoted rates. 25.a) Two sets of Engineering, electrical drawings, and Installation and O&M manuals are to be supplied. Bidders shall provide complete technical datasheets for each equipment giving details of the specifications along with make/makes in their bid along with the basic design of the power plant and power evacuation, synchronization, along with protection equipment is deemed to be included in the quoted rates. 43 b) All test and calibration certificates, wherever applicable.26. The bidder shall take entire responsibility for the electrical safety of the installation(s) and personnel, including connectivity with the grid and follow all the safety rules & regulations applicable as per local guidelines and regulations, etc. Insurance of the installers (of the vendor) working abroad is mandatory.27. (a) The bidder shall take entire responsibility for the electrical safety of the installation(s) and personnel, including connectivity with the grid and follow all the safety rules & regulations applicable as per local guidelines and regulations, etc. Insurance of the installers (of the vendor) working abroad is mandatory.(b) The contractor will carry out fortnightly, monthly, quarterly and annual maintenance as per Proforma of Appendix here-in-after respectively. In case the contractor fails to carry out the above maintenance following penalty per Solar will be imposed. 44 (i) Not carrying out maintenance fortnightly- Rs 2500.00(ii) Not carrying out maintenance Monthly- Rs 5000.00(iii) Not carrying out maintenance quarterly- Rs 7000.00(iv) Not carrying out maintenance annually - Rs 10000.00(c) The Contractor shall be responsible for ensuring production of 800 kW AC output of electricity at the injection point of RMU atleast once in a year from the SPV plant. In case the output is less than 800 kW AC unit, it will be deemed as under-designed plant. The contractor will be responsible for making good the shortfall by repair / replacement of the SPV Plant free of cost. Delay in this regard will attract monetary penalty to be amounted for the period wef very next day of the completion of Phase-I to the date of completion of rectification / replacement by multiplying the maximum value of units less generated than 800 kW AC for every day with the prevailing rate of electricity tariff of WBSEDCL Rate of electricity in West Bengal is Rs 6.52 per unit as in Sep 2025.(d) Maintenance and supervision shall be done by trained men for the safe operation of Solar’s contractor shall carry out fortnightly servicing including adjustment lubrication, repair of replacement fo parts if necessary. In addition to fortnightly servicing contractor’s senior mechanic of foreman shall carryout the inspection as per maintenance schedule and make necessary entries in the proforma attached here-in-after duly signed by Contractor & Engg-in-Charge as applicable kept in the switch room for this purpose. It will be the responsibility of the contractor to see that the maintenance schedule book is maintained properly by their senior mechanic or foreman. They shall promptly attend and call back & shall not be kept pending for more than 4 hours unless it has the prior approval of the Garrison Engineer. 45 (e) For any repairs/ replacement of Solar the contractor shall always be aware of time factor following are the fixed time (including Sunday/Holiday) for repair/replacement of parts/components/ accessories which shall be adhered to :- (i) Minor repair/ replacement- 4 hours (ii) Major repair/ replacement - 1day(f) The decision of the GE regarding Minor/Major repair shall be final conclusive and binding. In case of failure on the part of the contractor to keep the solar’s in running condition within the stipulated period mentioned in above the contractor is to pay penalty charges as mentioned below subject maximum of 10% of the total contract value and after that measurement will not be considered for the same defective Solar till it is in satisfactory working condition :-(i)Upto 12 hours @ 2000/-(ii) Above 12 Hours and up to 24 hours @ 5000/-.28. RFID Tag scanner of reputed make shall be provided by the contractor is deemed to be included in the quoted rates.29. Existing Room at 33 KV Switch Yard shall be used for SCADA/ Solar equipment/Control Room. 46 30. Surface preparation and laying of light yellow/white coloured interlocking tiles of appropriate thickness under the whole area of PV module array to make a reflecting surface for bifacial Solar PV module alongwith periodical water sprinkling arrangement for cooling of interlocking tiles is deemed to be included in the quoted rates. 31.The complete system shall include chemical earthing (as per OEM recommendations) and earth strip/cable etc for earth of SPV module, array, inverter,DC & AC boxes /LA etc as per latest IS/MNRE/IREDA/NISE/SECI/ALMM specifications and guidelines is deemed to be included in the quoted rates. Earth resistance shall not be more than 3 Ohms .32. The mounting steel structure shall be as per IS 2061-1992 and galvanizing as per IS 4759 and should withstand WIND Load as per relevant IS Code/NBC.33.Soil Stabliztion testing certificate needs to be required before completion of physical completion of work (Phase-I) so that the performance of the PV Plant is not affected in Highly Soiled areas for minimum 25 years. 47 34. M&O (Phase-II) should be finalize at the planning stage itself. The important point are as under:- (a) The thermal imaging of pv panel should be taken once a year for checking its health including hot spots.(b) The cleaning cycle of panel should be fixed as per the ratio of short circuit current falling below 0.9. The cleaning provision shoul be made available before evacuating the power.(c) The shutdown duration of inverter should be monitored and recorded and analyzed 48 Supplying, Installation, Testing & Commissioning including design, manufacture and testing at works of indoor type , IP 4X ,floor mounted metal clad, 11 KV VCB panel board totally enclosed & fully interlocked, Horizontal drawout, Horizontal isolation type breaker as per IEC-62271-100/200, as amended up to date and additional specifications, having capacities as mentioned below, single break, trip free mechanism, motor charged and manually/electrically closing breaker suitable for use on 11 KV,3 Phase, 50Hz A.C. supply with STC 25 KA for 3 Sec.Internal Arc for AFLR 25kA at rated voltage for 0.1s at individual compartments i.e. Busbar, VCB and cable compartment.complete with self contained, fully interlocked, rack in and rack out mechanism, air insulated and encapsulated copper bus bars of 800 Amps capacity, breaker featured with mechanical ON/OFF indicator with hand trip device, spring release coil, shunt trip coil and auxiliary switch of 8 NO + 8 NC andequipped with following switch gears and accessories.The panel shall be complete with following switchgear and accessories. The structure of the switchgear must be fabricated using steel sheets coatedwith Alu-Zinc (Aluminium Zinc alloy)/PRINTED CRCA All major sub-components (switchgear, relays, meter & vacuum interrupters) shall be of same make. VCB and vacuum interrupters shall be designed for 100 short circuit operations at full short circuit of 25KA. Breaker shall be roll on floor type/ CASSET TYPE. Separate earthing truck shall be required for each bus earthing & cable earthing. Earthing truck shall be so designed that it is impossible to earth a live. It shall be provided with capacitive voltage divider and complete with audio visual annunciation, one for each panel. Item Continued as 2.01 to 2.04 49 INCOMINGS & Outgoing VCBs :Type : Air insulated VCB, autoreclosing, system voltage :- 11kV + 5%, 50 Hz+ 5%, 3 phase, rated voltage : 12kV, rated current : 800A in 40 ° C ambient, Short time rating for 3 sec : 26.3 kA, Short Circuit Making Current : 65 kA, insulation level (PF rms/ impulse peak) : 35 kA/75kA, System Ground : Solidly Earthed,Duty Cycle : 0 - 0.3 sec - CO - 3 min - CO, Break/ Make time :- Not more than 5 Cycle, Range for Auxiliary voltage for Closing / Tripping / Spring Charging : 85-110%/ 70-110%/85-110%. of rated voltage. The VCB must withstand 10000 mechanical, & 100 at rated short circuit current. The breakers should have auxiliary contact 6 No+ 6 NC, in minimum. The used Breakers will comply with IEC 62271/ IS 13118. Qty. - 3 Nos (1 no Incomer & 1 outgoings)Busbar: Rated Current : 800A @ 40°C ambient, Material : Silver Plated /Tined , High conductivity elecrolytic Copper Bus Bar sleeve :Heat Shrinkable PVC Sleeve with joints having full voltage soft PVC shroude Short time rating for 1sec :26.3kA -1 setCurrent Transformer:Voltage class: As specified in Circuit breaker ; Type: cast resin type, Dual core, Dual Ratio , Barden :10VA; Class insulation : Class E or better . Protection core: 5P10, Metering : 1.0 , Short time rating for 1 sec :26.3kA Ratio :300-150/1-1, 7 setsBus Potential Transformer: Rated Voltage : Primary - 11000 / ✓3 , Sec -110✓3; Type : Cast resin , draw out type, 3- phase , 3-limb complete with HV fuses . Barden : 100VA per phase ; Class of insulation : Class F or Better , Accuracy Class: 1.0;Rated Voltage factor : 1.2 continuous, 1.5 for 30 Secs. PT shouldbe drawnout type and serivce continuously shall be indepandent of Breaker trolly position...1set 50 Relay for Control & Protection: Numerical Type IDMT Relay (50/51, 50N/5IN) with two elements for overcurrent and earth fault having settings 50% to 200% for overcurrent and 20% to 80% for earth fault in equal steps with time and current settings and high set instantaneous unit. Additionally, condition monitoring CB wear, condition monitoring CT supervision, disturbance recorder, undervoltage & over voltage protection, trip circuit supervisioncan be measured through the relay. The device shall support webserver/web HMI through which we can monitor and control the relays over a ethernet Lan network. Licenses for theprogramming software shall be provided free of cost.The numerical relay shall have large mimic-based LCD screen display . .The relay shall have 8 Digital inputs and 8 Digital Outputs and one additional watchdog ouput.The device has to aloe controlling of min. six objects (circuit breakers, disconnectors and grounding switches). Controlling has to be done by “select-execute” or “direct control” principle. Controlling has to be possible by: through local HMI, remote communication, via digital input or via function key. Events has to be readable to SCADA systems, front panel or by setting software.The sample rate of the recording has to settable to 32samples/cycle.The devices shall provide storage up to events 2000 based on the resolution.The device shall support following communication protocols: Native IEC 61850 ed1 & ed2, Modbus TCP. The IEC 61850 communication has to support peer to peer communication (GOOSE) if requiredThe IEC 61850 interface must be able to configure through setting software. Also the same setting software has to be able to generate ICD filesThe device shall have KEMA IEC61850 edition 2 certificates - 3 sets. High Speed Master Trip relay VAX31- 3 Set, Ttrip circuit supervision relay-VAJH13-3 set6 Window Annunciation Facia . with ACCEPT, RESET & TEST Push Button - 3 set . Auxillary relay for Transmission faults (VAA33)- - 3 Set 51 Metering: Meters: 1-NosUL&CE Multifunction Digital meter displaying Voltage, Amps, kWh, kW, P.F., Active, reactive, apparent energy , disturbance direction detection, Individual harmonic up to the 63rd harmonic. at least 256 samples/cyclewith ethernet Port with inbuilt webserver and complying to IEC 61557-12, IEC 62053-22 certified by third party laboratory.Temperature Monitoring Sensor for the Three Phases of Incomer VCB Panel :Supply, installation, testing & commissioning ofthermal monitoring system to be provided to detect abnormal temperatures due to faulty connections and to prevent equipment B19damage. The switchgear shall have wireless temperature measurement sensors at all critical points:(a) 3 nos. foreach phase at incoming side cable joints The wireless temperature sensors installed on conductors shall be :(i) Installed with direct contact to hot point, to achieve accuracy of +/- 2°C(ii) Self-power (no auxiliary supply, no battery)(a) communicate wirelessly(c) Operate from -25°C to 125 °CThe system shall allow 2 configurable thresholds (pre-alarm and alarm). This system shall have integrated algorithms enabling to anticipate as early as possible an abnormal temperature, before damage occur (strong predictive capacity) and generate alarm through SCADA/monitoring software. Thermal sensor shall beself powered by the network current. Temperature data is sent via Zigbee wireless communication to provide high performance and accurate thermal monitoring. The sensor is secured to the connection point and is in direct contact with the measured point. Smartphones or tablets (with a Zigbee communication dongle) can be used with our Thermal Connect mobile application to scan data locally and can replace the need of periodic infrared scanning. Thermal sensors should comply to following standards:1 EN/IEC 61010,2010 2. UL 61010-12, 20123. ETSI EN 300238, 2012 V1.0.1 4. IEEE 802.15.4, 2013 52 Power Pack shall be with 220Volt AC Input & 24 volt DC continuous output suitable for closing /tripping indication of HT panel boards with 2nos 12Volt 100AH maintenance free batteries, chatging unit for trip system complete with suitable capacity dogital MFM connections with 2.5sq mm FRLS inaulated copper conductor cable etc as required.-4 set.The 11 KV HT Switchboard of 1 panel,shall bewith all accessories, interconnections,internal wiring, labels, space heaters etc. complete as required.3 panels shall be mechanically interlocked in such a way that only one operates at a time and multifunctional digital meters shall be interconnected and programmed in such a way that total consumption will come in one meter summating both of them.Note: 1. Quotated rates shall be inclusive of construction of foundation for the installation of VCB as per OEM drawing.2. The equipment shall be tested by SEI post sucessful installtion and report shall be submitted to this office. 53 Design, Manufacturing, Supply, Installation, Testing and Commissioning of 3 way 12 kV rated Ring Main Unit ofwith Fault Level 21KA 3 sec internal ARC 1 sec for tank and cable box , consisiting of 630A12 kV rated , 2 nos motorized type VCB as incomers & 1 load break switch as outgoings with metering modules along with necessary Earth Switches,battery and battery charger for shunt trip arrangement andMotor and other auxiliary circuit operation, HT CopperBus bar with current density not more than 1.6A/sq. mm as per detailed description as follows: RMU Construction: The switchgear and busbar shall all be contained in a stainless steel enclosure filled with SF6 at 0.3 bar (300 hPa) relative pressure to ensure the insulation and breaking functions. Sealed for life, the enclosure shall meet the sealed pressure system criterion in accordance with the IEC 62271-1 standard (§ 3.6.5.4): a volume for which no further gas processing is required during its entire expected life”. In addition, manufacturer shall confirm that maximum leakage rate is lower than 0,1 % / year. It shall provide full insulation, making the switchgear insensitive to the environment (temporary flooding, high humidity...), IP67 degrees of protection in accordance with recommendation IEC 60529 § 14.2.7. No SF6 gas handling required at site. Thus assembled, the active parts of the switchgear shall be maintenance-free and the switchboard shall be low-maintenance. The switchgear operating mechanism shall have an IP2X protection and cable chamber shall be IP55, Over all IP protection shall be IP55 . The tank shall be made of at least 2mm unpainted stainless steel. Item Continued as 3.01 to 3.05 54 VCB is the preferred dielectric medium for MV RMUs. Oil filled switchgear will not be considered. RMU shall be in accordance with IEC 60376.Any accidental overpressure inside the sealed chamber will be limited by the opening of a pressure limiting device in the lower part of the enclosure. Gas will be released to the rear or the bottom of the switchboard away from the operator and internal arc tested for both cable and tank for 21KA 1sec AFLR with test conducted with minimum 3 functions TankNumber of mechanical operations of Circuit breaker 2000 O/C , Number of electrical operations at full loop current for LBS: 100 O/C , Number of electrical operations at full loop current for CB: 2000 O/C,. Manufacturer shall provide type test report to prove compliance with IEC 62271-200 Annex A, Internal arc classification class AFL with 21kA 1s for the enclosure. Make of the RMU, vaccum intrtupter , relay & meter shall be of same OEM. All the test certificate shall be in the name of the OEM only . If there is any name change / acquisition by other OEM happened for the RMU then test cerificates shall contain the new OEM name only.HT System : 3 phase -3 wire , HT Fault level21 kA, Power System earthing - solindly earthed at up stream source, HT Copper Bus with Short Time Curent rating 21 kA for 1 Sec ( 3Sec), Continuous current rating at least 630 A. tank and cable chamberof RMU must be IAC rated for 21 kA for 1 Sec AFLR. Design ambient to be considered as 40 Deg C.HT Circuit Breaker :(i) There shall be 1nos.load break switches as incomings and 2 nos 12 kV rated VCBas outgoing ( total 3 nos.) . The circuit breakers shall be fixed type. All of the switchgear shall be capable of withstanding this current without any damage being caused, in accordance with the recommendations IEC 62271-1 and IEC 62271-200.Loss of service continuity class: LSC2(ii) The Circuit Breaker must be rated for 12 kV ( nominal Voltage), 28 kV/75 kVp ,3 Phase, 50 Hz, Short Circuit Fault Level of 21 kA for 3 sec. 55 (iii) No. Of Close Coils - 01 no. operable at 24 V DC (85% - 110%)/ Spring Assited Closing, No. of Trip Coils - 01 nos. ,operabale at 24 V DC ( 70% - 110%) for shunt trip.(iv) Provision for supervision of the shunt Trip Circuits for the Trip Coils to be provided. (v)Switchgear classification: PM class(vi) Loss of service continuity class: LSC2(vii) Duty Cycle : O – 3min – CO – 3min – CO, Vacuum Circuit breaker shall be of M1, E2, C1 duty and capable for minimum 50 short circuit breaking operation at full short circuit level.(viii) STC rating 21 kA for 3 Sec (for Vacuum Interrupter).(ix)Vacuum Interruptor must be hermetically sealed and must comply IEC 60056 ( along with latest amendments). Vaccum interrupter shall be of same make as RMU(x)Circuit Breaker to be equipped with Suitable tripping arrangement with push button, Mechanical counter to assess the total number of operations of the breaker, Mechanical ON / OFF indicator, Auxiliary switches, Auxiliary Contacts( at least 2 NO + 2 NC of Class 2 category), Emergency trip push button.(xi) The Operating mechanism shall be spring charged motor operated/ spring assisted as per OEM type tested design type with Spring Charge Universal motor operable on 24 V DC / 230 V AC.(xii)Suitable monitoring of Bircuit Breaker status ( ON, OFF, Trip, CB Spring charged if applicable), Trip Circuit Healthy / Unhealthy, DC healthy/unhealthyto be provided using (xiii) Voltage Presence Indicator shall be provided against each HT circuit ( against each VCB) on line side for knowing the presence of line enerzisation status.(xiv)Number of Mechanical operations at full rated current for breaker: 2000 O/C 56 HT CT /PT : Load Break Switch - 11 KV, 630A, 21KA for 3sec Motorized Load break switch; with built in line side manual earth switch. Earthing should be completed within 2 operations only(i.e 1. Main switch - OFF, 2. Earth switch - ON). LBS shall have 3 positions, open or disconnected, closed and earthed, and will be constructed in such a way that interlocking prevents unauthorized operations. For earth switch, manual opening and closing will be driven by a fast-acting /snap action mechanism, independent of operator action. LBS and earth switch shall have a min of 1000 (M1) mechanical operations ,and 5 nos closing operations at rated SC current. LBS should have 100 electrical operations at rated current. LBS & Earth Switch should have separate apertures for operation.i) One set of 03 nos. ( for 3 phases) dual core Cast Resin CTs for Eachincomer VCBcomplying with IEC:60185 & IS 2705 ( along with latest amendments) , Core -1 - 400-200/1 A , 2.5 VA, Cl 0.5 for metering ; Core-2 - 400-200/1 A, 2.5 VA , 5P10 for Protection.ii) 01 no. of 03 phase Dual Core PT forHT bus ( 11 kV)with protection HRC fuseCore 1- 11kV /√3 / 110V/√3, Cl 0.5s, 50VACore 2- 11kV /√3 / 110V/3, Cl 3P, 50VA(iii) Multifunction Meter:2 Nos. 3 phaseDigital Multifunction Meter6400NGwith Voltage, Amps, kWh, kW, P.F., Active, reactive, apparent energy , disturbance direction detection, Individual harmonic up to the 63rd harmonic. at least 256 samples/cyclewith ethernet Port with inbuilt webserver and complying to IEC 61557-12, IEC 62053-22 certified by third party laboratory.for each VCB panel ( 96 mm x 96 mm) , Flush mounted, Class 1 conforming to IEC 62053-22 ( along with latest amendments). 57 Protection Relay: (i) 2 Nos. of Numerical Type Self-powered IDMT Relay(50/51, 50N/5IN) with two elements for overcurrent and earth fault having settings 50% to 200% for overcurrent and 20% to 80% for earth fault in equal steps with time and current settings and high set instantaneous unit. Relay should communicate on Modbus RS-485.(ii) Each VCB must have separate Anti Pumping Relay / Antipumping feature through motorization circuit.Fault Passageindicator: The FPI shall facilitate quick detection of faulty section of line. The fault indication may be on the basis of monitoring fault current flow through the device. The FPI should be self-powered and should have internal lithium battery for external indication and setting of FPI in the absence of current.The FPIs shall include: Fault detection - Phase to phase and Phase to earth faults.One potential- free output contacts for hardwiring to RTUs. On this basis, the SCADA/DMS will be able to monitor phase / earth fault condition.Local fault indications - LCD display on FPI front panel along with LED indication on front panel of RMU enclosure.Multiple reset option : End of time delay (Adjustable from 2 to 16 Hrs)Remote reset (Via potential free input contact of FPI)Manual reset (Reset button on front panel of FPI)Automatic reset on current restoration.The characteristics of the FPIs shall include: Phase fault thresholds configurable from at least 100 to 800 A,Earth fault thresholds configurable from at least 20 to 200 AMultiple number of steps for adjusting phase and earth fault thresholds. Fault current duration range configurable from at least 40 ms to 100 ms in 20 ms steps and further 100 ms to 300 ms in 50 ms steps. Variations with respect to these characteristics may be acceptable as long as they prove applicable and provide the same or better flexibility. 58 EARTHING : The cables shall be earthed by an earthing switch with short-circuit making capacity, in compliance with IEC 62271-102 standard. The earthing switch can only be operated when the switch is open. The switch and earthing switch operating mechanism shall have a mechanical endurance of at least 1000 operations. Integrated line side Earth switches shall be provided in each HT Circuit. ( against each VCB)RMU Bushing & Cable Termination: It is preferable to have all bushings accessible from the front of the RMU. Bushings along the sides or the rear of the RMU are not acceptable.For each cable compartment, the bushing shall be at the same height in order to facilitate a possible reversal of the cables. The bushing should be conveniently located for working with cables specified and allow for the termination of these cables: - 630 A M16 bolted connectors for switch-disconnectors and vacuum circuit breakers functions.The profiles of the cable connection bushings shall be in compliance with IEC-60137 standard. Cable clamps:A cable clamp arrangement must be provided for all network cables terminated on the RMU.Provision for Cable Entry: There shall be suitable provsion for Cable entry from bottom through 3 mm thick CRCA steel thick detachable gland plate along with provision for termination of 2 runs of 3 c X 300 Sq mm 11 kV (E ) , XLPE insulated Aluminium Cables (for HT side) and at LT side runs of cables matching with outgoing MCCB current rating.Note: (i) Quotated rates shall be inclusive of foundation for the installation of VCB as per OEM drawing.(ii) The equipment shall be tested by SEIaftersuccessful installtion and report shall be submitted to this office and cost deemed to inclusive in qoated rates 59 M&L for water proof, 3 core PVC insulated and PVC sheathed, copper conductor cable of size 1.5 sqmm, 1100 Volts grade including PVC conduits properly fixed on steel poles using GI wire for electrical connection of street light fittings, complete all as specified and directed. 60 Supply and fixing junction box having protection dust proof, acid resistant, shock proof, fire retardent self extinguisher for outside installation with knockout entry for cable of size 10 - 25 sqmm andminimum size 295x195x95 mm with terminals, with and includingbrackets for street light pole mounting andone 6A MCB SP complete all as specified and directed. 61 M&L for Advanceencapsulated compound based Chemical earthing CPRI tesed maintenance free , pipein -pipe technology upgraded(Zinc & Alloy coated). , Zinc & Alloy coated (80 -100) microns with pure zinc (99.9%) & Alloy coating (200-250) microns. Earthing system conforming IS 3034. The outer and inner pipe should be 76.2 mm and 41.9 mm dia respectively of3 mtrs long zinc coated with additional special alloy coating 300 mm on top side for additional protection of the terminal . The annular space between the pipes to be filled up with Compactfill (CF) (Crystalline Conductive) mixture which should bemachine pressed in the pipes not disintegrate or collapse when outer pipe corrodes . The inner pipe should be extended with terminals for connectivity.The job includes digging the pitsin any type of hard densesoilof min size 1000 X 1000 X 3050 mm depth taking out excavated soil, lowering/ placing thethe pipe in pipe earth electrode in pit in center ,filling of pure conductolite back filling compound (BFC Conductolite) having excellent moisture retaining capacity in 300 mm around the electrode(minimum 4 bags of 25 KG per pit per unit) or more qty of backfillcompoundas required to fill around the the elctrode in 300 mmin circumfrance of electrode . Contractor has to fill the remaining portion of pit withlow resistivity soil (agriculture soil) free from stones etcs, to be bring from out side defence landas the soil resistivity ofStn is very high and mixed with min 3 Bags of 50 Kg each of Bantonide clay. The BFC should be eco friendly it should not contain envernmently hazardous material/metal having ROHS certification from NABL accredited lab.The earth pit should be provided with a FRP earth pit cover for protection and safe guard of terminals. The material of earth electrodeshould have good electrical conductivity & anti corrosion property in wide range of soil conditions. The job also include M & L for in PCC(1:3:6) typeC-1 around the FRP cover for support and foundation and colouring the PCC work withdesired colour.completeall as specified and directed. Item Continued as 6.01 62 Note : (i) Design of earth electrode should be of pipein-pipetechnology .(ii) Contractor have to submit literature of earth electrode and get the make approved of GE before procurement.(iii) The earth electrode shall be CPRI tested to withstand short current test for 60kA rms for 1.0 second and 150kA for peak current.(iv) Contarctor has to fill pure back fill compound conductolite all around the earth electrodein 300 mm bore up to full depth of bore.(v) Contractor shall refill the pit with low resistivity soil (agriculature soil ) free fron stone etc and mixed with 06 bags of Bentonite of 25 Kg each to achive the low resistance values. (vi) copper strip will be laid below 60 cm from ground level and connected to test point through plinth protection. This Earthing System used for VCB and RMU only. For Solar Power Plant Earthing System is already deemed to be included in quoted rates.(vii) Necessary cost of repair to plinth protection and connected plate and earth continuity conductor by providing 2 x brass nuts bolts and brazing of joints,bringing argiculture soil from out side defence land and cost of 6 x Bags of bentonidedeemed to be included in the item rate.(viii) Contractor has to clear the side and disposed off the excavated soil from pit on completion of work. 63 SAFETY EQUIPMENTSSupply and fixing Rubber hand gloves suitable for 11 KVas per OEM recommendationcomplete all as specified and directed. 64 S&F for glass framed Shock treatment chart both in Hindi & Englishand connected accessoriescomplete all as specified and directed. 65 S&F for dry powder chemical type 4.5 kg fire extinguiser with clamps and connectedaccessories ISI Marked complete all as specified and directed. 66 S&F for single line diagram, schematic diagrams etc. of A1 size on suitable Aluminium sheet including lamination etc. as required as per OEM recommendationcomplete all as specified and directed. 67 Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed. 68 Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundation, manholes, laying of UG cables/pipes etc. not exceeding 10 Sq.m on plan and getting out in soft/loose or any type of soil complete all as specified and directed. 69 Removing excavated material (soils) to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed. 70 Returning filling in, soft/looseor any type of soil including spreading leveling watering and ramming complete all as specified and directed. 71 Excavation in post holes (or similar holes) in soft/loose soil each n.exc 0.50 cum, getting out,returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n.exc 50 m and making good surface all as specified & as directed. 72 M&L for RCC M-20, design mix (using 20mm graded crushed stone aggregate), including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. 73 M&L for steel tubular swaged poles complete with cast iron base plate, finial taper plugs, bolts, nuts & screws as specified type 410 SP-31, 9.0 meter longinclusive of two coats of aluminium paint over one primer coat of red oxide zinc chrome primer including preparation of surfaces complete all as specified and directed.NOTE : (a) The poles shall confirm to IS - 2713 & each component pipe shall be ISI Marked & confirm to IS - 1161. (b) Necessary earthwork, PCC etc. shall be measured & paid separately under relevant items of work. 74 S & F LED Street lights nominal power 90 Watt, LED of Make Osram; Bridgelux ; Philips; Nicha; Cree; Samsung, LED wattage of minimum 3 watt each and Maximum 5 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 120 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 80%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with polyester powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hourswith IK10 and L70 on including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed.(i) If connection.cable from pole Juction box to street light and street light bracket up to 2 mtrs be included and measured in unit rate item, Beyond 2 mtrs of length to be paid seperately under respective items.(ii)At location where street lights/flood light are connected through overhead conductor, connection cable from light fitting to overhead conductor is deemed to be incl in the item rate. (iii) All LED street light/flood lights shall be properly connected with earth dolly provided with fittings and steel poles earth bolt.(iv)All LED lights have replacement warranty of 5 years from the date of completion of the contract accordingly condition 46 of GCC (IAFW-2249) shall be amended to extent mention above. Contractor has to submittwarranty certificate from manufacturer . Payment of light fitting will be released after receipt of 3 year replacement warranty certificate from manufacturer.(v) The LED lights will replaced bythe contractor free of cost in the case of manufacturing defects and Failure due to electrical impact if not connected properly with earth. Hence it is contractor responsibility to connect the light fitting earth wire and shall be grounded properly.(vi) The contractor shall submit the surge protection certificate and Type test certificate LM 79, LM 80 for luminaries from LED manufactutre. 75 M&L for Cement concrete (1:4:8) type D2, (Using 40mm graded crushed stone aggregate) as in foundations of poles and stay, filling and mass concrete complete all as specified and directed. 76 M&L for plain cement concrete (1:3:6), type-C2 (40mm graded crushed stone aggregate) as in foundation, filling and mass-concrete, coping etc for pole foundationwith and including necessary formwork complete all as specified and directed. 77 M&L PCC (1:2:4) type B2 (using 40 mm graded crushed stone aggregate) as in foundations, filling and mass concrete and copingwith and including necessary formwork complete all as specified and directed. 78 Material & labour for earthing complete with copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick burried directly in ground (Earth pit not less than 4 mtr deep below ground level) with top edge of the plate not less than 3.25 mtrbelow ground level connected to copper strip 20 x 3.15 mm as earth lead by brass nut bolts washer including brazing the copper strip with copper plate as shown in electrical plate No 3 connected to earth test point including necessary excavation for earth pitin hard dense soil, rocky / disintergate rock, filling charcoal and salt around the plate in layers , filling the pit with low resistivity agriculture soil free from stones, to be bring from out side defence land and mixed with Bentonite , (4 bags of 25 Kg each ), construction ofinspection pit ( earth pit chamber) of brick work of size 600 x 600 x 600 mmwith PCC copping of 1 :1.5: 3, 12.5 mm aggregate A1 with MS sheet 2.8 mm plate cover on frame ofangle iron of size 40 x 40 x 5 mm with , wire mess, funnel, test point, 40 mm dia GI protection pipelightgrade and20 mm GI peforated pipefor wateringetc complete and testing on completion. The electrode and lead shall be of copper all as specified and directed by Engr-in-charge (Copper strip upto 7.5 RM will be included in the item rate and copper strip beyond 7.5 RM will be measured seperately Item Continued as 22.01 79 NOTE :-(i) Contractor shall uselow reisistivity fresh agriculture soil , mixed with 4 x Bags of bentoniteclay of 25 Kg each for refillingthe pit to achive the desired resistance.(ii) copper strip will be laid below 60 cm from ground level and connected to test point through plinth protection(iii) Necessary cost of repair to plinth protection as per existing specification and connected plate and earth continuity conductor by providing 2 x brass nuts bolts and brazing of joints,bringing argiculture soil from out side defence land and cost of 3 x Bags of bentonitedeemed to be included in the item rate.(iv) Contractor has to clear the side and disposed off the excavated soil from pit on completion of work.(v) Contractor has to submit test report of earthing after completing the earthing.(vi) Bentonite clay should be Conf to IS 6186: 1986.(vii) The cost ofCopper strip of size 20X3.15 mm from top of earth plate upto 7.5 meter above ground level is deemed to be included in the unit rate of above item.and copper strip beyond 7.5 RM will be measured seperately.(viii). All the joints in copper strip and connection with Earth Plate to be welded through brazing and in addition by proving brass nut bolt and washer are deemed to be included in the unit rate. (ix) Cost of brazing / welding and nut bolts are deemed to be included in the unit rate. (x) Cost includes removal of excavated soil upto a distance of 100 mtrs. 80 Supply and fixing copper strip of size 20 x 3.15mm as earth continuity conductor or main earthing lead fixed on V typeporcelain insulator, 4 BM, heavy duty ( ceramic bus bar supportinsulator off whitecolour ofsuitable for mounting strip of 20 mm wide x 3.15 min thick) saddle to wall, buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20 x 3.15 mm copper strip brazingto each joints and connected with by providingbrassnut boltsand washer including test point all as specified and directed by Engr in Charge. Note : Insulators shall be provided on every 50 cm. (Minimum 2 x insulators to be provided in every 1 x metre of strip and rate of the same deemed to included in quoated rates) 81 M&L sand cushioning (dry) in trenches for protection of UG cables (below, above and around the cable laid in trenches) of 230mm spreding thickness and consolidated (punned) upto 180mm thickness, complete all as specified and directed. 82 Supplying and laying un-reinforced precast concrete cable cover, class HV, type 1 with peak, size 300mm x 180mm x 40mm complete all as specified and as directed. 83 M&L for GI pipe 100 mm bore, light grade with all fittings and fixtures (ISI Marked), laid in trenches, under road or fixing on wall/ pole /crossing drain /nallah etc. of bore complete all as specified and directed. 84 Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4 core ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc.with all fixing & connecting accessories complete all as specified and directed. 85 Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc.with all fixing & connecting accessories complete all as specified and directed. 86 Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc.with all fixing & connecting accessories complete all as specified and directed. 87 Supply, laying & testing PP-R IS-15801 (Polypropylene random co-polymer) pipe 3-layer 63 mm dia (outer green coloured UV stablilized, middle black coloured UV stabilized and innermost layer white coloured with anti-microbial property) fusion welded grade PN-10 SDR-11 ( Pressure nominal 10KGS/cm2 ) having thermal stability for hot & cold water supply including all types of plain and brss threaded PPR fittings of any size such as elbow, tees, FTA and MTA etc laid in trenches complete all as specified and as directed.Note:The contractor shall submit 15 Years warranty certificate against leakageand defect liabilty period deemed to amended acordingly. 88 Supply, laying & testing PP-R IS-15801 (Polypropylene random co-polymer) pipe 3-layer 32 mm dia (outer green coloured UV stablilized, middle black coloured UV stabilized and innermost layer white coloured with anti-microbial property) fusion welded grade PN-10 SDR-11 ( Pressure nominal 10KGS/cm2 ) having thermal stability for hot & cold water supply including all types of plain and brss threaded PPR fittings of any size such as elbow, tees, FTA and MTA etc laid in trenches complete all as specified and as directed.Note:The contractor shall submit 15 Years warranty certificate against leakageand defect liabilty period deemed to amended acordingly. 89 S&F for 63mm (OD) PP-R Gate valves (brass insert)and connected acessories complete all as specified and as directed. 90 S&F for 32mm (OD) PP-R Gate valves (brass insert) nd connected acessories complete all as specified and as directed. 91 M&L for hard core of gauge not exceeding 63mm with broken stone or boulders, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and directed. 92 Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M35 grade conforming to IS 15658-2006 made by block making machine with strong vibratory compaction, of approved size, design & shape, cast in rubber mould, glossy finish of approved colour, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. 93 S&F for RCC pipes of 600 mm dia, NP-2 laid and jointed complete with collars complete all as specified and directed. 94 S&F for 250mm bore Flue pipes of mild steel sheet, black, in suitable lengths as approved by GE and fixed to walls complete all as specified and directed. 95 M&L for Brickwork with fly ash bricks (modular bricks ), straight or curved on plan exc 6m mean radius, built in cement mortar(1:6) complete all as specified and directed. 96 Material and labour for plastering 15 mm thick (in two coats of 10 mm and 5 mm thick) on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:4 with integral water proofing compound finished even and fair complete all as specified and as directed. Note: - Water proofing compound will be deemed to included in qoated rates. 97 M&L for applying three coats of white wash on newly plastered wall surfaces including preparation of surface complete all as specified and directed. 98 S & F hot rolled low tensile structural steel of grade E165 as per IS 15911: 2010 as in hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. Wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar works complete all as specified and as directed. 99 S & F hot rolled medium and high tensile structural steel of grade E165 as per IS 15911: 2010 as in framed work such as grills, grating, etc., with ends of bars of shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework water tanks and similar work complete all as specified and directed by Engineer-in-charge. 100 S&F flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. 101 S&F MS screw bolt (machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc. 5 cm and n. exc 10 cm long, diameter of neck 5 to 10 mm complete all as specified and directed. 102 Supply and fixinggalvanized steel chain link fence fabric of mesh size as approved , made out of 4 mm nominal dia of mesh wireconforming to IS 2712-2003 and having zinc coating of type heavy as laid down in IS-4826 including line wires/ binding complete all as specified and as directed(A Board of Officers under the orders of GE shall be convened to ascertain the weight per square metre of galvanized steel wire chain link fencing brought at site by the contractor against each lot of materials). 103 S&F 10mm round bars Fe-410-W (Gde-250) quality-A or Fe-290-(Gde-E-165) as in stiffner to hold the chain link fencing fixed with angle iron post inclucinding necessary welding and fixing arrangement at ends complete all as specified and directed . 104 S&F Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steelpins, etc. complete all as specified and directed . 105 Material and Labour for applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on new steel and iron surface exceeding 10 cm in width or girth including preparation of surfaces complete all as specified and directed. 106 Material and Labour for applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on new steel and iron surface not exceeding 10 cm in width or girth including preparation of surfaces complete all as specified and directed. 107 Materials and Labour for reinforced cement concrete M-20design mixin columns; pillars; piers; posts; struts etc,complete all as specified and directed. 108 S&F for Mild steel TMT bars 10mm dia and over, conforming to Fe 500 D, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. 109 S & F for mild steel TMT bars 6 to 8 mm dia, conforming to Fe 500 D cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, stirup,hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. 110 M&L for construction of valve chamber with MS sheet cover 3mm thick with angle iron) frame of size 50 x 50 x 6mm and locking arrangements including painting one coat of primer followed by two coats of black sysnthetic paint including excvation and earth work in any type of soil,PCC (1:4:8) type D2 in foundation ,PCC benching 1:2;4 type B-1 ,PCC (1:5:8) block masonry 20 cm thick in cement mortor (1:6),10 mm thick plastering in CM 1:4 ,PCC bed in (1:3:6) and coping 50mm hick in cement concrete 1:2:4 type B1 using 20mm stone aggregate including necessary formwork,paintin one coat of red oxide and two coats of bituminious black paint on all steel surfaces as specified and as directed of sizes 800mm x 800mm x800mm (internnal dimensions) complete all as specified and as directed. 111 Sch A Part-II (Phase-II) 112 Providing Services for Manning and Operation of Solar Power Plant 0.8 MWp near 33 KV receiving stationat Sevoke Mil Station for FIRST YEAR after completion of Ph-I of the subject work with oneskilledcategory Electricianhaving certificate of Surya Mitra from NISE) for twoshifts of 8 hour, one helper (semi-skilled category) in two shift of 8 hrs eachcontinuous operation (including Sunday/Holiday) to maintain sub station in/out side Panels, Invertor, DC junction box, VCB as specified, including daily and weekly check up including cleaning of PV modules complete with suitable cleaning cloths etc , upkeeping the installation operational and in health condition, having own conveyance and communication system like mobile etc. complete, for Solar Power Plant with all minor consumable and expendable items and labour and tools for smooth and efficient operation complete all as specified and directed by Engineer-in-Charge. Make of spare parts / equipments of the Solar Power Plant :- Same as installed in the preceding phase of the work.Repair or replacement ofdefective components or spare parts will be carried out free of cost under DLP and comprehensive Maintenance as per OEM recommendation up to DLP period included in BOQ item No. 1.00. The Contractor may submit his claim for every months on pro-rata basis subject to condition 64 of IAFW-2249 (General Conditions of Contracts)The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 17,92,949.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. Item Continued as 56.02 to 56.06 113 NOTES :- In addition to and Manning, Operation and Maintenance of Solar Power Plant, the following works will also be carried out by deputing addl manpower where required, to the entire satisfaction of Engr-in-Charge.(a) Minor repairs and preventive maintenance required to ensure serviceability and efficiency of complete MRS complex including supply of HT 11 KV fuse wire of proper sizeand minor spares such as nut, bolts, spring, lock nut of VCB/OCB as per sample, broom, duster, grass cutting tools, phawara, pick axes for cleaning/grass cutting of complete at Sub Stn Complex. 114 (b) Record of activities such as voltage / current / PF / Energy consumed / temp of transformers, break downs, day to day maintenance of Solar PV Plant etc.(c) The contractor shall ensure that all safety precautions are strictly exercised by the staff employed by him.Adherance to IE rules and statutory rules in vogue must be ensured.The contractor shall be fully responsible for any mishap that occurs due to any fault of the employee or due to non adherance of safety norms.(d) Record of activities such as attendance register, duty roster, pay distribution register of the whole staff employed by the contractor.(e) The electrician staff employed by the contractor shall be ITI holder with four years experience. 115 (g) Security lights within the complex will be operate by the tenderer. (h) The under mentioned tool kitwill be provided at site with person on duty :-(i) Electrician tool kit such as screw driver set, tester, test lamp, cutting plier, insulation tape, fuse wire of required size. (ii) Tongue tester(iii) HT megger(iv) First aid box (v) Shock treatment chart duly framed(vi) 33 and 11 KV Hand gloves(vii) 33 KV discharge rod withcopper chain(viii)) Helmet -02 nos(ix) Suitable Footwear - 02 nos(x) Cotton protective clothing with long sleeves duly embossed with GE Sevoke as directed. The tenderersquoted rates shall be deemed to be include the cost of all above provisions and nothing extra will be paid on any account. 116 (xi) The Bidders shall abide by the latest Labour rules and minimum wages Act. Wagespaid by the bidders to the persons employed shall not be less than the minimum wages fixed by the state/central government from time to time whichever is higher. (xii) The Bidders is responsible for insurance, EPF, ESI, Bonus, Labour welfare cess et., as applicable and shall be paid to the workmen as per existing Labour rules/ Acts/ regulations and rate quoted shall be deemed to be included for the same.(xiii) Dress Code : The bidders shall provide the workmen with Dark Blue Colour uniform {formal pant & T-shirt} with labels showing/ printed i.e. Name of the firm and designation on front and on the back of the T-shirt along with protective clothing, Industrial safety shoes, protective gears like helmet, safety belt etc..(xiv) Supervision and attending of all incoming & outgoing Solar Power Plant equipment metering equipments & monitoring to loads & other parameters of incomming & outgoing feeders & maintaining log sheet and attendance sheet. 117 INSURANCE: The Bidders shall also insure the workmen employed on the job.The Bidders shall be responsible for all Accidents/Injuries happening to the workmen. Any accident causing minor/fatal injury, partial disability due to any untoward incident or non-adherence to safety and IE regulations or fault in maintaining of internal electric supply system or on account of any mishandling/ wrong operation/ lack of knowledge of safety precautions or on account of any circumstances beyond his/ their control, the bidders shall be solely responsible for settling all claims of compensation to the deceased, falling which department will have a right to recover any sum indicated/ claimed by Labour commissioner/court authorities. No claim whatsoever will be entertained in this regard. No compensation is payable by the department on this account. Bidders shall provide first aid boxes to meet any emergency situations. 118 All as perBOQ serial item No 56.01 to 56.06 as mentioned here-in-before but for SECOND YEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 18,75,076.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 119 All as perBOQ serial item No 56.01 to 56.06 as mentioned here-in-before but for THIRD YEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 19,61,175.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 120 All as perBOQ serial item No 56.01 to 56.06 as mentioned here-in-before but for FOURTH YEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 20,51,671.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 121 All as perBOQ serial item No 56.01 to 56.06 as mentioned here-in-before but for FIFTHYEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 21,46,848.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 122 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but for SIXTH YEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 22,46,564.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 123 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but for Seventh YEAR after completion of Ph-I.NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 23,51,386.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 124 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but forEight YEAR after completion of Ph-I.NOTE :-(a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 24,61,315.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 125 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but for Ninth YEAR after completion of Ph-I.NOTE :-(a)The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 25,76,917.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 126 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but for TENTH YEAR after completion of Ph-I.NOTE :-(a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 27,03,441.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 127 Comprehenisve maintenance of Solar Power Plant 0.8 MWpfor FIRST YEAR after expiry of DLP of Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d)Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum andcost of item priced upto ₹500.00 shall be deemed to be included in the comprehenisve maintenance quoted cost. Repairs of minor components any other major components are also in the scope and cost of labour for minor / major components is deemed to be included in the quoted rate for this item.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 128 Comprehenisve maintenance of Solar Power Plant 0.8 MWpfor SECOND YEAR after DLPof Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d)Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum and cost up to Rs. 500.00 shall be deemed to be included in the comprehenisve maintenance quoted costrepairs of minor components any other major components are also in the scope of Annual Maintenance Contract.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 129 Comprehenisve maintenance ofSolar Power Plant 0.8 MWpfor THIRD YEAR after DLPof Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d)Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum and cost up to Rs. 500.00 shall be deemed to be included in the comprehenisve maintenance quoted cost repairs of minor components any other major components are also in the scope of Annual Maintenance Contract.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 130 Comprehenisve maintenance ofSolar Power Plant 0.8 MWpfor FORTH YEAR after DLP of Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d)Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum and cost up to Rs. 500.00 shall be deemed to be included in the comprehenisve maintenance quoted cost repairs of minor components any other major components are also in the scope of Annual Maintenance Contract.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 131 Comprehenisve maintenance of Solar Power Plant 0.8 MWpfor FIFTH YEAR after DLPof Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM. (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d) Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum and cost up to Rs. 500.00 shall be deemed to be included in the comprehenisve maintenance quoted cost repairs of minor components any other major components are also in the scope of Annual Maintenance Contract.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 132 Prime Cost Sum. The prime cost to be used as directed by the Accepting Officer vide Condition 1 (v) and 5 of IAFW-2249 (General Condition of Contracts) forming part of the tender documents.(a) Provide a prime cost of Rs.3,00,000.00 forsupply only of spare parts required for comprehensive maintenance after expiry of DLP of Phase-I, through a BOO convened by the CWE. The spares shall procured directly from the OEMs or their aurhorised distributor/dealer as approved by GE.(b) Bidders/Contractors quoted amount shall be inclusive of his overhead and profit and including all taxes and insert amount to cover all. The Bidders/Contractors is to quote lump sum amount under Column 6 covering all the aspects mentioned here in before, representing (%) percentage under Column 9, Above/Below (+ or - denomination) the Prime Cost Sum inserted by MES under Column 5. However, the quoted amount under Column 6 shall not exceed 15% (Fifteen Percentage) of Prime Cost Sum inserted by MES under Column 5. In case, the Bidders/Contractors quoted amount is in excess of 15% of the estimated amount, the same shall be restricted to 15% (Fifteen Percentage) and the amount quoted shall be corrected accordingly to work out the contract sum. Item Continued as 70.01 133 NOTE:-Prime Cost Sum shall be governed in terms of condition 1 (v) and 5 of IAFW-2249 (General Condition of Contract) and to be regularized through Deviation Order. The following procedure shall be adopted to execute the Prime Cost Sum :-(a) Step –I Service Engineer of OEM along with site executive shall visit every month for Preventive and corrective maintenance on all the Solar Power Plant as specified in BOQ herein before, and undertake routine comprehensive maintenance and identify the list of damage / defective spare parts in Solar Power Plant. Service Engineer have to submit report to concerned Engr-in Charge and BOO before undertaking replacement/ repairs, except in case of emergency.(b) Step –II Subsequently BOO will verify the same and submit the finding to the CWE after assembly of board in terms of CA Provision for concurrence.(c) Step –III After concurrence of BOO, the Engr-in-Charge will direct the contractor and the service provider to replace the unserviceable spare parts.(d) Step –IV Serviceability certificate of Solar Power Plant duly signed by the Service Engineer, BOO findings, GST enabled purchase voucher for the replaced spare parts alongwith draft DO details shall be submitted to the GE for placing of DO’s. The advance on account shall be accompanied alongwith the said DO’s for payment.
Contract Date : 17 Mar, 2026   |   Contract Value : 6.86 Crore
Disclaimer

We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.

Tender Detail
Website https://etender.cpwd.gov.in/login.html
Quantity
MSME Exemption No
Tender Type Open Tender
Startup Exemption Click Here
Competitive Bidding NCB
Similar Tenders
TENDER INSIGHTS

858

Electric Tenders
Live
CLICK TO KNOW MAXIMUM WIN

Tell us about your Product / Services,

We will Find Tenders for you

🇮🇳 +91
TenderDetail
Loading tenders