TDR : 57114244
Central Public Works Department

Tender Brief :

new delhi, Delhi

Tender For Providing Networking And Electrical Item For Various Ministries As Per Requirement In Kartavya Bhawan 1,2 And 3, New Delhi.

Published: 20 Aug 2026
Opening: 28 Aug 2026
Closing: 28 Aug 2026
Amount: 88.77 Lakhs
EMD: 1.77 Lakhs
Tender Fee: Ref. Documents


Works 3D Printer Accounting Software Active Harmonic Filter Actuator Aerial Cable
4
Days Left
Tender Summary / Eligibility Criteria
Tender For Providing Networking And Electrical Item For Various Ministries As Per Requirement In Kartavya Bhawan 1,2 And 3, New Delhi.
Documents Download All
aba39da1-060b-496c-946e-b7124f899683
aba39da1-060b-496c-946e-b7124f899683.html
DocumentsList
DocumentsList.zip
No Boq
No Corrigendum
Probable Bidders

AI engine predicts probable bidders to help you bid strategically.

MSME Exception
Explore More →
Technical
Tender involves procurement of high capacity electrical equipment including diaphragm coupling of pump & motor with 90kW capacity at 2900 RPM. The project scope includes installation, testing, commissioning and operational handover.
Previous / Similar Result
BRR : 10350861 repair maintenance of Various Electrical Installation And Mechanical Equipment At Ncc Bhawan, Sector-19, Rohini, Delhi Dg. (Sh Providing Fire Retardant Electrical Lv/Hv Flooring In Sub-Station And Lift Machine Rooms.)- 1 Supplying & Fixing of Fire retardant / Extinguishing Elect. insulated met flooring sheet of 2.0 mm thick + 10% according to IS: 15652, 2006 meeting requirements of IS: 3043, IS: 5216 (Part 1, 2& 3), IS: 8437 and IEC 479 Pub-1, Tested for breakdown strength, tensile/ elongation, ageing, properties, Insulations resistance, effects of acid, alkaline, diesel & transformer oil, leakage current test, having min. width of 1000 mm + 20 mm. All allied material such as pu-resin, chemi bound (Hardener), spl. PVC adhesive, liquid primer Annexure A Clause C of IS: 15652 and suitable for Class-A upto 3.3 KV without HT Movement. 2 Supplying & Fixing of Fire retardant / Extinguishing Elect. insulated met flooring of 2.5 mm thick + 10% according to IS: 15652, 2006 meeting requirements of IS: 3043, IS: 5216 (Part 1,2& 3), IS: 8437 and IEC 479 Pub-1, Tested for breakdown strength, tensile/ elongation, ageing, properties, Insulations resistance, effects of acid, alkaline, diesel & transformer oil, leakage current test, having min. width of 1000 mm+ 20 mm. All allied material such as pu-resin, chemi bound (Hardener), spl. PVC adhesive, liquid primer and sealing material Annexure A Clause C of IS: 15652 and suitable for Class-B upto 11 KV with HT Movement.
Contract Date : Ref. Documents   |   Contract Value : Ref. Documents
BRR : 6703233 Appointment of an Event Management Agency on turnkey basis for Designing, Execution and Management/ Supervision of arrangements, activities and ancillary services for an Event being organized in conjunction with Republic Day Celebrations – 2025 at areas in front of Red Fort, Delhi (Gyan Path and two (2) adjoining lawns); 1 EntranceArchesmadeofmetalframewith fabric print 11mtr (W) x 4.5 mtr (H) duly finished as per design approved by ITDC/ Principal Organizer. 2 Entrance Arches made of metal frame with fabric print 6 mtr (W) x 4.5 mtr (H) duly finished as per design approved by ITDC/ Principal Organizer. 3 Help desk: Delhi Police, CCTV, Medical Room, Fire Control Room, Traffic police etc Waterproof Pagodas measuring 5 mtr x 5 mtr, Covered from all sides and top with lockable door for entry and exit having wooden platform base of 10 cm with new carpet (colour as per our requirement) 4 H/Desk - Octonorm Tables 3 ft x 1 .5ft 5 H/Desk· - Banquet chairs with chair covers 6 H/Desk - Power points 7 H/Desk · Dust bin 8 H/Desk - Facia 9 H/Desk - Adequate lighting (comprising of 3 light fittings of 40 Watt each or compatible LED Light Fittings in each pagoda) 10 Office set up of Concerned Ministries (Ministry of Tourism, Culture, Defence, ASI, Textile, Delhi Police,CPWD,ITDCetc.)Waterproof Pagodas measuring 5 mtr x 5 mtr , Covered from all sides and top with lockable door for entry and exithaving wooden platform base of 10 cm. with new carpet (colour as per our requirement) 11 Office setup - Octonorm Tables 3ft x 1.5ft 12 Office setup - Banquet chairs with chair covers 13 Office setup - Power points 14 Office setup - Dust bin 15 Office setup - Fascia 16 Office setup - Adequate lighting (comprising of 3 light fittings of 40 Watt each or compatible LED Light Fittings in each pagoda) 17 Office set up of Concerned Ministries ( Ministry of Road Transport,NECRT,MoEF&CC,Department of Post, Council of Architect, Ministry of Jal Shakti etc.)Water Proof Pagodas(10mtrx5mtr)Structureeachwith wooden platform base of 10 cm, carpet with each to have 12 light fittings of 40 watts each or compatibleLEDlightfittings,Furniture- OctonormTable3’x1.5’-08Nos,Banquet chairs with chair covers 8 nos, Power Points 08 Nos, Spot lights -15 Nos, Dustbin -02 No, etc. withModularstructureinside.EachModular structure within each theme Pavilion to have Presentable Almirah (all equal size) with lockable facility to be placed in each Central Ministry/ Department Pavilion pagoda and 1 No. fascia. Each Pavilion (10 mtr x 5 mtr ) to have additional average Electricity load of 6 KW for each pavilionincluding Electric load required from 22nd January,2025 for fabrication of stalls) 18 Office setup - Octonorm Tables 3ft x 1.5ft 19 Office setup - Banquet chairs with chair covers 20 Office setup - Power points 21 Office setup - Dust bin 22 Office setup - Fascia 23 Office setup - Adequate lighting (comprising of 3 light fittings of 40 Watt each or compatible LED Light Fittings in each pagoda) 24 Security Items / services - Baggage Scanning Machines(as per requirements of security agencies ) 25 Security Items / services – Door Frame Metal Detector at entry points (as per requirements of security agencies) with footfall counting device 26 Security Items/services -Manpowerfor Frisking, detection, security etc. arrangements by trained and uniformed, presentable security personnel (on shift basis of 12 Hours per day) at identified points and as required: - Male - 125 Nos. per day of event on shift basis in ( Day/Night) 27 Security Items / services - Manpower for Frisking, detection, security etc. arrangements by trained and uniformed, presentable security personnel (on shift basis of 12 Hours per day) at identified points and as required: - Female- 50 Nos per day of eventin Day Shift only 28 Bouncers for Dais / Stage arrangements by trained and uniformed, presentable security personnel (on shift basis of 12 Hours per day) required; - Female 10 Nos per day of the event in day shift only) Men 10 Nos per day of the Event. 29 Security Items / services - Queue managers (ribbonised steel barricading) ( as per requirements of security agencies ) 30 Security Items / services - Security Tower ( Machaan) ( as per requirements of security agencies ) 31 CULTURE STAGE REQUIREMENTStage set up measuring 72ft x 52 ft. of at least three different levels ( 6ft,7ft &8ft) covered with grey carpet; Stairs: one stair complete on front side; and two stairs 6 feet wide on right & left side is required.Risers: approx. 8 ft. x 16 ft. with 1½ ft. height suitable for 8 to 10 artists to sit with dari/Kaleen covered with white cloth and Frontal steps all along the width.RedCarpet coveringthefrontofthe stage up to Sofa sets seating rows. 32 CULTURE AREA INCLUDING Well Ventilated Green rooms of size of 625 sq. ft. each separate for male and female interconnected with cultural stage. The green rooms to accommodate 150 artists in each at a time in vicinity of stage area, with wooden platformof 10cm with carpet, 20 banquets chairs with covers each, Garments hanger stand- 5 Nos each, 6 mirrors each, 2 shelves each. Green Rooms to be well lit with 6 nos. each light fitting of 40 watt each or compatible LED light fittings. 33 CULTURE AREA INCLUDING - Holding areas of 10 mtrs x 5mtrs each for cultural artists at an area in the vicinity of the cultural stage with wooden platform of 10 cm, carpet, Banquet chairswithcovers-20nos.eachandlightfittings of 40 watt- 4 nos. each or compatible LED light fittings. 34 Cultural Area: Air-conditioned portable Toilets in vicinity of main cultural stage with dedicated staff deployment with toiletries, amenities and adequate water supply at all time of event. 35 CULTURE AREA INCLUDING – VIP ExecutiveHigh Back Chair for Dais 36 CULTURE AREA INCLUDING – Centre Tablefor Dais 37 CULTURE AREA INCLUDING – Podium withPodium Boards 38 CULTURE AREA INCLUDING - Seating foraudience:- Sofa Double Seaters 39 CULTURE AREA INCLUDING - Seating foraudience:- Centre Tables( Coffee Table size) 40 CULTURE AREA INCLUDING - Seating foraudience:- Banquet chairs with chair covers and bands 41 CULTURE AREA INCLUDING - StageLighting:- Box Truss( 1000mm) 80 ft x 60 ft 42 CULTURE AREA INCLUDING - StageLighting:- Centre beam 70 ft 43 CULTURE AREA INCLUDING - StageLighting:- Side Cuts Section – 16 ft 44 CULTURE AREA INCLUDING - StageLighting:- LED PAR LIGHTS 54 x 3 Watt 45 CULTURE AREA INCLUDING - StageLighting:- Par 64 sealed beam 46 CULTURE AREA INCLUDING - StageLighting:- Laser light 47 CULTURE AREA INCLUDING - StageLighting:- Sharpy 48 CULTURE AREA INCLUDING - StageLighting:- Pointy 49 CULTURE AREA INCLUDING - StageLighting:- Aura 50 CULTURE AREA INCLUDING - StageLighting:- Profile 51 CULTURE AREA INCLUDING - StageLighting:- Follow Spot 52 CULTURE AREA INCLUDING - StageLighting:- Mole fays 53 CULTURE AREA INCLUDING - StageLighting:- Haze Machine 54 CULTURE AREA INCLUDING - Stage Lighting:- Grand MA Lighting CONTROL Panel with NPU. 55 PC LED Warm-400 watts 56 LED Fresnel warm 57 Dimmer Par 500 KW Electronic 58 Avolite Board 59 Cultural Area -Video - LED WALL - Centre 52ft x 16ft 60 Cultural Area - Video - Side Wings – LED Wall3.5 ft x16ft 61 Cultural Area - Video - Watch out Servers 62 Cultural Area - Video - Plasma TV 52 inch on stand for backstage 63 Cultural Area - Multi Camera HD Set up with 04 cameras with editing table, Jimmy Jip with crane and adequate manpower to operate 64 Cultural Area - Sound Requirements - line array D and B 65 Cultural Area - Sound Requirements - Base D and B 66 Cultural Area -Sound Requirements - Stage Monitor 67 Cultural Area - Sound Requirements - Side Fill Line array approx. 800 Watt each 68 Cultural Area - Sound Requirements- Corded Mikes 69 Cultural Area - Sound Requirements - Cordless Mikes 70 Cultural Area - Sound Requirements- Headset mike 71 Cultural Area - Sound Requirements - Foot Mike 72 Dynamic wired mikes of different sizes 73 Digital Console 96 Channels (sound engineers and adequate number of technicians to be available at all times during the event.) 74 Carpet on 26.01.2025 for Parade Gyanpath and outer area with Pasting. 75 Saw dust provision 76 Spinkler for water spray 77 Drummer Technical Rider1) Drum Kit: DW Performance or Yamaha Maple Custom (or similar).Completing: drums: bass drum 22’, tom 10’, tom 12’,floor tom16’;snare 14’,Cymbalspaistechokes; Hi Hat 14”, Ride 20”, Crash 16” and Splash 10” stands: one for hi-hat, one for snare drum, 4 (four)boom stands for cymbals besides hi-hat stand; Drum chair with adjustable height; all elements of drum kit should be located on a carpet or rubber covering (against sliding);Drum Riser is a mus + Monitors + in ear monitor-One shaker,2) in-ear Monitor3) Wedge Monitor One jackOne monitorOne keyboard stand One notation stand 78 Guitar tech rider:1. Guitar amp (Fender twin reverb/ Marshall JCM 900)2. Guitar stand3. 1 Amp(Fender Twin Reverb or JCM 900 or Marshal100HCFX Amp Head with 4 Speaker Marshal Cabinet )4. 1 Mic With Stand (Shure SM57)5. 2 DI Box6. 4 Guitar Aux7. 1 Guitar Stand8. In Ear monitor-1 no.9. Notation stand- -1 no. 79 Keyboard: (Keyboard TR) stereo wires 2DI Keyboard amp Keyboard stand 80 MAIN ARTISTSEENHIESER e845 only wireless MEDIUM BOOM STANDSMultifunction Power Extension Boards- 4 Nos 81 Harmonium1. SM58 One Laptop 82 Drums:Pearl session / Master / Pearl decade maple Or• Tama superstar Hyper drive/Tama Silver star/Star Classic• HI Hat 14 inch, Crash 18 inch, 16 inch Crash Ride 20 inch, China 16 inch, Splash 10 inch, with Stands and 1 extra Boom Stand(All from K Custom series of ZILDJIAN)Drum Mic Kit- Audix Mic Kit OR PGA and( Beta 52A For Kick separately) 83 OUTPUT PATCH 84 INPUT CHANNEL MONITOR 85 TaIkBactMac.ForCoordinationStageto Mixing Console with Monitor 86 Power source must be 280V, earthed aria connected ro a safety system thai breaks tke c rcu›r whenever Phase is connected to ground, 4 Power outlet Stripe are required for the musicians on Stage placed according to where the musicians at onstage. 87 Floor Monitor Monitors fPRx 8 S/SRX 8t5) 88 8 x: Floor Monitor S wzT1 carry their individual preferred mix for the musicians on stage side file 89 JBL SRX 725 WITH SRX 718-2 PAIR 90 Channel 22-23 Keyboard 2nos. DI BOX with PowerPoint Vocal mic. SM58 1no. With Tripod 8uom stand 91 MONITOR MIK.8 & 9 92 JBL Lirte Array w th sub Low 93 Two LED Plasma 60 inches with touch screen facility with dedicated 10 MBPS lease line for internet connectivity 94 Cultural Area Console : a dedicated 100 mpbs board band internet connectivity for live coverage & sharing on various SocialMedia Platforms 95 Reserved Lounge: To cater requirements for Dignitaries as per security agencies.- Construction of Space Frame Pillar less, Water Proof, Fire Retardant Aluminum hanger Structure 20m x 10m with fabric false ceiling with top and covered from all sides with wooden platform base of 10 cm with new carpet, Double Door Entrance and Exit, Well Lit befittingthe Ambiance as per our requirement- using fittings, cables etc of ISI standards, well ventilated, with colorful fabric and befitting interiors.10Nos. for entire Event Flower Bouquets and 8 Nos. for entire Event table top flower arrangements on daily basis. All material used should be in consonance to fire safety norms and adhere to fire safety standards. 96 Reserved Lounge: 10 nos. round table of 8 pax seating capacity each and 100 banquet chairs with covers. 97 Reserved Lounge: Sound system with adequate speakers, amplifier etc. with 8 number table mikes; 2 podium mikes and 4 number cordless mikes 98 Reserved Lounge: Sofa set ( Double Seaters) 99 Reserved Lounge: Centre Tables 100 Reserved Lounge: Side Tables 101 Reserved Lounge: Air Circulators 102 Reserved Lounge: Air-conditioned portable Toilets in vicinity of VIP Hanger with dedicated staff deployment with toiletries, amenities and adequate water supply at all time of event. 103 Reserved Lounge: Internet lease line 20 Mbps forcreating Wi-Fi zone with complete set up / infrastructure 104 Hangar for Ministry of Information & Broadcasting (I&B) Exhibition - Construction of 01 Nos. for entire Event of Space Framepillar less, Water Proof, Fire Retardant, Safe Aluminum Hanger Structure (10mx20m) with fabric false ceiling, 10cm wooden platform base with carpet and covered from three sides plus top and well lit. 20 number octonorm tables, 40 banquet chairs with cover. 05 Nos. air circulators and 10 Nos pedestal fans. The average electrical load should be 10KW including load required from 22nd January 2025fabrication of exhibition area. All materialused should be in consonance to fire safety norms and adhere to fire safety standards. 105 Hangar for Ministry of Tourism Experiential Zone - Construction of 01 Nos. for entire Event of Space Frame pillar less, Water Proof, Fire Retardant, Safe Aluminum Hanger Structure (10mx20m) with fabric false ceiling, 10cm wooden platform base with carpet and covered from three sides plus top and well lit. 20 number octonorm tables, 40 banquet chairs with cover. 05 Nos. air circulators and 10 Nos pedestal fans. The average electrical load should be 10KW including load required from 22nd January 2025 for fabrication of exhibition area. All material used should be in consonance to fire safety norms and adhere to fire safety standards. 106 Hangar for Ministry of AYUSH - Construction of 01 Nos. for entire Event of Space Frame pillar less, Water Proof, Fire Retardant, Safe Aluminum Hanger Structure (10 mtr. X 20 mtr.) with fabric false ceiling, 10cm wooden platform base withcarpet and covered from three sides plus top and well lit. 20 number octonorm tables, 40 banquet chairs with cover. 05 Nos. air circulators and 10 Nos pedestal fans. The average electrical load should be 10KW including load required from 22nd January 2025for fabrication of exhibition area. All materialused shouldbe in consonance to fire safety norms and adhere to fire safety standards 107 Hangar for Ministry of Railways - Construction of 01 Nos. for entireEvent of Space Frame pillar less, Water Proof, Fire Retardant, Safe Aluminum Hanger Structure (10 mtr. x 10 mtr.) with fabric false ceiling, 10cm wooden platform basewith carpet and covered from three sides plus top and well lit. 10 number octonorm tables, 20 banquet chairs with cover. 02 Nos. air circulators and 5 Nos pedestal fans. The average electrical load should be 10KW including load required from 22nd January 2025 for fabrication of exhibition area. All material used should be in consonance to fire safety norms and adhere to fire safety standards 108 Hangar for Ministry of Food Processing - Construction of 01 Nos. for entireEvent of Space Frame pillar less, Water Proof, Fire Retardant, Safe Aluminum Hanger Structure (10 mtr. x 10 mtr.) with fabric false ceiling, 10cm wooden platform basewith carpet and covered from three sides plus top and well lit. 10 number octonorm tables, 20 banquet chairs with cover. 02 Nos. air circulators and 5 Nos pedestal fans. The average electrical load should be 10KW including load required from 22nd January 2025 for fabrication of exhibition area. All material used should be in consonance to fire safety norms and adhere to fire safety standards 109 Hangar for Footwear Design & Development Institute - Construction of 01 Nos. for entire Event of Space Frame pillar less, Water Proof, Fire Retardant, Safe Aluminum Hanger Structure (10 mtr. x10 mtr.) with fabric false ceiling, 10cm wooden platform basewith carpet and covered from three sides plus top and well lit. 10 number octonorm tables, 20 banquet chairs with cover. 02 Nos. air circulators and 5 Nos pedestal fans. The average electrical load should be 10KW including load required from 22nd January 2025for fabrication of exhibition area. All material used should be in consonance to fire safety norms and adhere to fire safety standards 110 Food Court: Gazebo: Water proof, Specialized covered structure on truss for all over the venue at food court. Flat roof structure size10mx10m with 10cm wooden flooring with carpet and thematic colorful decoration to give a festive look. 111 Food Court - Water Proof Pagodas (5 mtr. x5 mtr.) with wooden platform base of 10 cm, carpet and each pagoda consisting of 3 light fittings of 40 watts each or compatible LED light fittings, Furniture- 4 Nos. working table of 6’ x 3’ with white disposable laminated sheets (to be changed regularly) 4 Nos. Plastic/ Banquet chairs, o1 No Pedestal fan, 5 Nos. power points, 1 nos. Dustbin, and 1 No. Fascia. The average Electricity load should be 5 KW in each pagoda. 112 Food Court – 5 Kitchen Areas of 250 SQM each tin Sheds and stone / brick surface with each kitchen areas consisting working tables of 6’ x 3’ (30 No’s in each kitchen area) with facility of water for cooking and dish washing. Kitchen area to be adjoining food court area. Allkitchen areas to have adequate fire safety measures like ABC fire extinguishers, sand bags, sand buckets, fire Marshalls etc., as per the fire safety guidelines 113 Food Court – Steel Dustbin with Garbage bags with clearance at regular interval and timely cleaning to maintain hygiene during the entire period of event. Theme of Swachh Bharat to be adhered. Large size with covers. 114 Food Court - Outdoor LED Wall 16ft x 8ft, with fabric Branding, Platform and sound system. 115 Food Court – Banquet (Plastic Tables) Tables Round with approx. 1.5 mtr. Dia (25 nos) with Umbrella and Rectangular/Square Dining Tables (25 Nos) with umbrella to accommodate 4/6 chairs each. Table covers for all tables. 116 Food Court – Banquet/ Plastic chairs with chair covers and bands/ Wooden chairs 117 Food Court - Bistro Tables with covers 118 Food Court - Stage for Performance of Nukkad nataks, size 50sq mtrs with 2 Ft height and steps on two side with sound system – 4 speakers, 10- standing mikes, 2 cordless mikes and 2 collar mikes. 119 Handicraft Area- Water Proof Pagodas (3 mtr. x 3 mtr.) Structure with wooden platform base of 10 cm, carpet and each pagoda to have 3 light fittings of 40 watts each or compatible LED light fittings, Spot Lights (9 nos), Furniture- 2 Nos. Octonorm Table 3’x 1.5’, Banquet/Plastic chairs with covers 2 nos., 3 Nos. Power Points, 1 No. Dustbin etc with Modular structure inside. Each Modular structure within each pagoda to have 9 shelves/slabs (3 on each wall) for display their products, Presentable Almirah (all equal size) withlockablefacilitytobeplacedineach handicraft and handloom pagoda and 1 No. fascia. 120 Handicraft Craft Area- Including: Dustbin with Garbage bags with clearance at regular interval and timely Cleaning to maintain hygiene during the entire period of event. Theme of Swachh Bharat to be adhered. 121 Handicraft Craft Area- Including: Outdoor LED Wall 16’x 8’ with fabric Branding with platform and sound system. 122 Handicraft Area: Internet lease line 20 Mbps for creating Wi-Fi zone with complete set up/ infrastructure 123 Handicraft Craft Area- Including State Theme Pavilions: Water Proof Pagodas (6 mtr x 6 mtr) Structure each with wooden platform base of10 cm, carpet with each to have 6 light fittingsof 40 watts each or compatible LED light fittings, Furniture- Octonorm Table 3’x 1.5’ - 04 Nos, Banquet chairs with chair covers 4 nos,Power Points 08 Nos, Spot lights -15 Nos, Dustbin -01 No, etc. with Modular structure inside.EachModularstructurewithineach theme Pavilion to have Presentable Almirah (all equal size) with lockable facility to be placed in each Theme Pavilion pagoda and 1 No. facia. Each theme Pavilion (6 mtr x 6 mtr) to have additional average Electricity load of 4 KW for each pavilionincluding Electric load required from 22nd January,2025 for fabrication of stalls) 124 HandicraftCraftArea-IncludingCentral Ministries/ Departments Pavilions: Water Proof Pagodas(5mtrx5mtr)Structureeachwith wooden platform base of 10 cm, carpet with each to have 6 light fittings of 40 watts each or compatibleLEDlightfittings,Furniture- OctonormTable3’x1.5’-04Nos,Banquet chairs with chair covers 4 nos, Power Points 08 Nos, Spot lights -15 Nos, Dustbin -01 No, etc. withModularstructureinside.EachModular structure within each theme Pavilion to have Presentable Almirah (all equal size) with lockable facility to be placed in each Central Ministry/ Department Pavilion pagoda and 1 No. fascia. Each Pavilion (5 mtr x 5 mtr ) to have additional average Electricity load of 4 KW for each pavilionincluding Electric load required from 22nd January,2025 for fabrication of stalls) 125 Neat Barricading and Fencing: Strong, proper, effective, presentable and complete barricading and fencing (using good material) of each tableau. (Total Tableaux expected to be 40) in parv area without disturbing the décor of the tableaux and inconvenience to the visitors 126 Military Band Stage - 4 sides open with for Military Bands of size 12m x 8.5m size with fabric branding on four sides with two side steps, carpet, with stage lighting (20 par /LED lights) from the front side of the stage 127 Military Band Stage -Sound system for Military Bands (48-piece band), 20 Micro phone, Cordless mikes -2nos and collar mikes- 2 nos, JacksandwiresforGuitar,keyboardand Octopad, Speakers -12 nos, Monitor speaker- 4 nos, Woofers and Tweeters, Mixer Channel, amplifier etc. 128 Military Band Stage - Banquet chairs with chair covers and bands with covers on band stages- 30 each stage 129 AYUSH Stage (Yoga Performance) 4 side open and covered on top with waterproof, stage for Yoga Performance of 12m x 8.5m size with 4ft. height with fabric branding on four sides with two side steps, carpet, with stage lighting (20 par/LED lights) from the front side of the stage. Sound System with Speakers, amplifiers,04 Cordless/Collar Mike & LED Wall 20’x10’ with platform. 130 Revolving / Rotating CCTV Cameras with wiring – (in entire event area including periphery, surrounding areas and parking),Installation and operation during entire event with Night vision capacity, monitoring andrecording and including deployment of technically trained manpower to monitor CCTV Operation. At the end of the event complete recording of all the days to be submitted in hard disk. 131 Fire Fighting - Provision (in entire event area including parking and surrounding areas) with firefighting equipment and manpower including Fire Tenders- 6, ABC Type fire extinguishers (10 Kg) – 300 Nos., Sand Buckets 300 andSand Bags – 750 Nos., Fire Marshalls– 40 Nos.and Fireman – 40 Nos. duly trained as perprevailing fire safety norms in uniform as per requirements of Authorities. 132 Conservancy and housekeeping - Provision of 250 Nos.cleaningStaffeach dayfor conservancyandmaintenanceoftheentire event areas including back areas, surrounding areasincludingsurroundingtoiletareasetc. Staff should be in proper uniform with cleaning equipment’s like vacuum cleaner, brooms, garbage bags etc. 133 Ceremonial Gas Filled balloons of Tri-colors and medium size- On the Inaugural Day only 134 Catering Arrangements at Reserved Lounge for 350 Pax (Each Day Menu to be changed on daily basis) Variety of Tea, coffee, cold beverages to be available on daily basis along with savory, sweet items like samosa, pakora, mini patties, dry Indian sweet, cookies and biscuits and 2 nos. water dispensing machines with 6 nos. drinking water jars of reputed brands approved by FSSAI with glass and disposable eco-friendly paper glasses. Well- groomed and uniformed staff to cater in Reserved Lounge. Menu to be change on daily basis 135 Office equipment’s: Computer with UPS 136 Office equipment’s : Printers along with paper for printing 137 Office equipment’s : Photocopier Machine with photocopier paper 138 Office equipment’s: Data cards for internet connectivity (4 GB) 139 Creative Branding in fabric: Creative and graphic designing of symbol of event with options, designing of view cutter, signage, backdrop, gates, 3D Cut out at various locations and direction indicator panels (as per input from principal organizer) in and aroundthe entire Parv Area and periphery. In addition, Interactive wall using good material- fabric, wood crafted jaalis, fabric prints using 3-D effects, selfie points; Graffiti walls, masks; Dance Postures with Special Emphasis on concepts like “Viksit Bharat @ 2047” “Vikas bhi Virasat bi” “One District One product”, “Nari Shakti, Millets, Life Millets, Travel for Life”,”Ek Bharat Shrestha Bharat” etc. to create and enhance the ambiance to give patriotic, festive and colorful look as well as for more public participation. The entire creatives for branding will be as perthe approval of Ministry of Tourism. 140 Cloth masking on frame of entire Boundary wall with 09 Feet height as per site requirement. 141 Creative Zone: for activities like short quiz competition, face painting/ tattoos, Karaoke activities with sound systems for public participation with activity co-coordinators and any other participative concepts with adequate coordinators etc. 142 30 Nos. of Drinking water dispensers equipped with 20 Ltr. Packaged Drinking water jar of reputed brand, replenish able CAN/JAR with sufficient disposable eco-friendlycups (CAN/JAR to be replaced at regular interval for un-interrupted supply) on daily basis for entire event. 1000 jars of 20 ltr per day 143 Still and Video Photography of entire Event – comprising of two single Camera Setup withlive projection in Food Court and Handicraftarea and at least 4 still photographers. Softcopy of photo shoot and video recording to be handed over on daily basis/as and whenrequired basis to ITDC for entire event including photo Album/s, DVD’s and teasers(short clippings of 3 to 5 minutes’ duration for the event as per the requirements of Ministry). 500 nos. of photos (5”x7”) with presentable album. All data pertaining to Bharat Parv to be delivered in a separate hard disk. 144 Toilets for General Public (Male and Females) with hand washers with liquid soap, proper water facility and their cleanliness at regular intervals and to maintain proper hygiene. All the toilets in the parv area to have provision of light inside. 145 Drinking water Tanker - 5000 Ltr. in Food Court area for kitchen purpose - on Daily basis. 10 Water tankers of 5000 liter each per day 146 Central PA System for entire venue (Help desk and control rooms ) 147 Battery Operated Golf Cart with driver for VIPs ( 5 +1) seating capacity each 148 Wheel Chairs for Differently abled persons 149 Walkie-TalkiesCommunicationDeviceswith System 150 Kitchen Apron of size 42”x24” with strap andgood quality fabricwith Incredible India branding 151 Umbrella large size with Branding 152 Media Hanger structure in Food Court Area: To cater requirementsfor Media Personnel: Construction of Space Frame Pillar less, Water Proof, Fire Retardant Aluminum hanger Structure with fabric false ceiling of size 15m x 10m with top and covered from all sides with wooden platform base of 10 cm with new carpet, Double Door Entrance and Exit, Well Lit befitting the Ambience as per our requirement- using fittings, cables etc of ISI standards, well ventilated, with colorful fabric and befitting interiors, 8 nos. table top flower arrangements on daily basis. All material used should be in consonance to fire safety norms & adhere to fire safety standards. 153 Media Lounge: Sofa set ( Double Seaters) 154 Media Lounge: Centre Tables 155 Media Lounge: Side Tables 156 Media Lounge: Office set –up: Computers with UPS 157 Media Lounge: Office set –up Black and White Printers with printing paper 158 Media Lounge: Office set –up Colour Printers with printing paper 159 Media Lounge: Internet lease line 20 Mbps for creating Wi-Fi zone with complete set up/infrastructure 160 Media Lounge: Output Box with 20 Points for Media 161 Media Lounge: Office set –up Photocopy Machine with adequate photocopy paper and stationery. 162 Media Lounge: Office setup - Octonorm Tables 3ft x 1.5ft 163 Media Lounge: Office setup - Banquet chairs with chair covers 164 Media Lounge: Office setup - Power points 165 Media Lounge: Office setup – s t e e lDust bin 166 Media Lounge: Arrangements for press briefing for 75-100 pax with banquet chairs and head table for 5 pax. Audio Visual arrangements with 5 mikes for head table and 4 cordless mikes for Q and A. Podium with Podium Board and 2 mikes. Flower arrangements for head table. 167 Catering Arrangements for 300 Pax per day at Media Lounge – (Each Day; Menu to be changed on daily basis). Variety of Tea, coffee, cold beverages to be available on daily basis along with savory, sweet items like samosa, pakora, mini patties, French fries, Dry Indian sweet, cookies and biscuits and 2 nos. water dispensing machines with 4 nos. drinking water jars of reputed brands approved by FSSAI with glasses and disposable eco-friendly paper glasses. Well-groomed and uniformed staff to cater in Media Lounge. 168 Media Lounge: Enclosure with 4 tables and chairs for dedicated catering 169 Air-conditioned portable toilets in vicinity of Media Lounge with dedicated staff deployment with toiletries, amenities and adequate power supply, water supply at all time of event. 170 Air Circulators for Media Hangar 171 Studio Kitchen Stage built on 18” inches raised wooden platform with 240 degree open,one entry and exit, size 12 x 8 with running water , attached mise en place area size 6 x 12 with running water facility and wash up area size 6x12 with sink and running water facility for Washing utensils, Size of Studio kitchen tent should be 20 x 40 with waterproof roof and barricading of 3 feet height with one entry and exit 172 Studio Kitchen: Theatre seating with 50 banquet chairs with covers in front of the studio kitchen. 173 Studio Kitchen Sofa set for VIP (Single Seater) 174 Studio Kitchen Power Point 15Amp 175 Studio Kitchen Electrical Load 176 Studio Kitchen: Video Camera placed on the working area and both sides with complete recording of entire event 177 Studio Kitchen LED Screen size 12x8 178 Studio Kitchen Collar Mike 179 Studio Kitchen Sound System with four Speaker 180 Studio Kitchen Fire Extinguishers –ABC Type 10 Kg, Sand Buckets and Sand Bags 181 Studio Kitchen Chef Caps with Incredible India Print 182 Studio Kitchen: 04 Utility workers for the studio kitchen per day 183 Pathway: Wooden platform of 10cm with grey carpet properly fixed throughout the Parv area to access the food court stalls, stage, Handicrafts and Handlooms stalls, State Theme Pavilion, VIP Lounge, Media Lounge, I&B Hangar, Hangars, offices of ministries, ITDC and Public Conveniences etc. The entire pathway to be with grey carpet (properly fixed) and approx. of size 8 ft. in front and 4 ft. in back of all the areas for smooth movement of public at large. The pathway to also be disabled friendly with interconnected pathway facility with platforms at various places includingconnectivity from Gyanpath to both the lawns. The pathways to be made with clear cut space for movement of differently abled persons’ in wheelchair. 184 Green net spread all across the parv area except the wooden platform ,Pathway to control Dust 185 Arrangement of sprinkling of water on daily basis to settle dust in the Parv area 186 Office Equipment: Comprising of: Computers with UPS and skilled manpower for Registration (preparation of badges etc.) with printers for colored and black and white printing along with stationery and paper. 187 Office Equipment: Heavy Duty Photocopier machine along with stationery and photocopy paper 188 Manpower: Ushering Staff per day (Female).12Hrs Shift Presentable, soft – spoken duly uniformed as per our requirement. Uniform to be provided by the bidder. 189 Manpower: Assistants (Male) per day 12 Hrs. shift. Presentable, soft – spoken duly uniformed as per our requirement. Uniform to be provided by the bidder. 190 Augmentation of lights over and above normal lighting for a well-lit Parv Area and surrounding area with 300 nos. LED metal lights. 191 Divider Railing: To regulate smooth entry and exit of visitors to the food court area and the tableaux/ handicraft area. As per our requirement. 192 Security Items or Services: Tensil Canopies of water proof stretchable fabric with MS Frame to cover 40ftx13 ft to cover 10 No’s DFMD at entry points 193 Tableaux Lighting: LED Parcan up lighters for Tableaux area 194 Water for cultural Artists: 4 nos. water dispensing machines with 50 nos of 20 litre each drinking water jars of reputed brands approved by FSSAI for the cultural artists eachday with ecofriendly disposable paper glasses 195 Promotional Tee Shirts with assorted sizes having Incredible India & Travel for LiFE Logo (as per size requirements) 196 Lamp Lighting With accessories viz oil, wicks, candle, floral decoration etc 197 ProvisionofcoveredkioskswithiPadsor equivalentsoftwarewithgadgetsatvarious places in the parv area to provide pre - ordering of food to avoid crowd at the counters in the food court. 198 Dedicated Social Media team to promote & publish the event on various social media platforms and under overall supervision/ Guidance / requirement of Ministry of Tourism. 199 A special stage of size 24ft x 12 ft with carpet and with all necessary audio visual systems at the venue for on – the – spot performance by kids up to 14 years old.
Contract Date : 26 Jan, 2025   |   Contract Value : 5.50 Crore
BRR : 10350863 Tender For annual repair maintenance of Various Electrical Installations And Mechanical Equipment At Ncc Bhawan, Sector 19, Rohini, Delhi Sh Servicing Repairing Of Apfc Panels- 1 Servicing/ overhauling of existing 2 nos. APFC panels as per Domain OEM requirements for correction of power factor of load and replacement of following APFC panel accessories for 415V 50 Hz supply in APFC panel including making connections, testing & commissioning i/c credit of old materialetc. complete as reqd. (As is where is basis) (Make: Domain)a) 10 KVAR round type three phase MPP capacitor - 4 nos.b) 15 KVAR round type three phase MPP capacitor - 4 nos.c) 20 KVAR round type three phase MPP capacitor - 10 nos.d) 8 stage Micro controller intelligent automatic relay -1 no.e) capacitor duty contactor 50 Amp CAP-24- 15 nos.f) LED indicator lamp- 18 nos. 2 Supplying and fixing following rating, three pole, 415 V, 10kA,C curve,miniature circuit breaker in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) 32 A 3 b) 63 A 4 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) Single pole 5 b) Double pole 6 Providing and fixing following rating and breaking capacityand pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.a) 400A, 50 KA, FPMCCB 7 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. a) 1 x 10 sq. Mm 8 Supplying, installation, testing and commissioning of 4 Pole Power Contactor with dust cover AC-1 rating 560 amp MCX 44 type with add on 2NO+2NC Auxilary contact block etc with equivalent model of and same frame size the work shall involve in complete work i/c modification of bus bar etc and control wiring as per the site condition as reqd. i/c dismantling the defective and credit for old dismantled materials. 9 Supplying and replacement of single phase 225mm sweep metal body Exhaust fan in the existing APFC panel including making connections, testing & commissioning and credit of old material etc. complete as reqd. (As is where is basis) 10 Credit for dismentled material incl. cost of dismentling.a) SP/DP MCB 11 b) MCB TP 32/63 Amp. 12 c) MCCB 400 Amp FP 13 d) faulty/ burnt out cu conductor cable
Contract Date : Ref. Documents   |   Contract Value : Ref. Documents
BRR : 1782089 Provision Of 33 Kv Receiving Stn At Af Station Palam, New Delhi. 1 Supply Laying Jointingtesting And Commissioning Of 33 Kv ( E ) Grade Of Size 185 Sqmm 3 Core ( Heavy Duty ) With Stranded Compacted Circular Aluminum Conductor, Conductor Screened With Extruded Semi-Conducting Compound, Xlpe Insulated, Insulationscreened With Extruded Semi-Conducting Compound In Combination With Copper Tape, Cores Laid Up, Inner Sheath Of Thermoplastic Tape, Pvc Bedded, Galvanized Steel Striparmoured And Over Allfrls Pvc Sheated Conforming Tois-7098, Part -Ii With Latest Amendmentslaid In Cable Ducts / Trays / Trenches / Encased In Gi Pipes / Rcc / Dwc Hdpe Pipes Complete All As Specified And Directed. 2 Note For Item No 1 ( I ) Each Cable Drum Not Less Than 500 Mtr Length ( Ii ) The Contractor Will Be Responsible For Taking Permission From Appropriate Authority I.E. Nhai / Igl / Cantt Board Or Other Units , If Needed For The Above Said Cable Work Necessary Payments For Work Clearence / Deposit Chargesfor Appropriate Authorityto Be Incuded In The Rate Quoted Above ( Iii ) Manual Excavation Has Be Carried Out At The Places Of Services Such As Of Near Existing Ht / Lt Cables, Ofc / Telecom Cables , Water / Gas Pipe / Sewage Pipe Lines, Area Drinages And Contractor Shall Be Responsible For Rectification Of Damages Immediately On Priority To The Damages Of Servicesoccured During Exection Of The Cable / Earth Work. 3 Supply, Jointing And Testing Of End Termination Joint Outdoor Type Heatshrinkble Type Complete With Jointing Material And Accessories Suitable For 33 Kv ( E ) Xlpe Armoured Aluminium Conductor Cable Of Size 185 Sqmm 3 Core Complete All As Specified And Directed. 4 Supply, Jointing And Testing Of End Termination Joint Indoor Type For 33 Kv Gis Panel Touch Proof Type Complete With Jointing Material And Accessories Suitable For 33 Kv ( E ) Xlpe Armoured Aluminium Conductor Cable Of Size 185 Sqmm 3 Core Complete All As Specified And Directed. 5 Supply, Jointing And Testing Of Straight Through Joint Outdoor Type Heatshrinkble Type Complete With Jointing Material And Accessories Suitable For 33 Kv ( E ) Xlpe Armoured Aluminium Conductor Cable Of Size 185 Sqmm 3 Core Complete All As Specified And Directed. 6 Supplying, Installing, Testing And Commissioning Of 33Kv, 630A, 25Ka / 3 -Sec, Iac, Aflr, Gas-Insulated Type Vcb Panel Making Arrangement Ip 4X Indoor Suitable, Floor-Mounted, Complying To Iec 62271-200 For Design, Manufacturing And Type-Tested, Including Internal Arc For Operator Safety ( Iac 26.3Ka / 1-Sec ) , Having 02 X Incomming +01 Bus Coupler+With 01 Bus Raiser+02 Out Goingall Inside Gas-Insulated Ip65 ( Partition Class : Partition Of Metal ) Ss 304 Grade Ss Tank ( 2.5 Mm Thickness ) , Flush-Front Mechanism Having Lockable Access Door With Mounted Bay-Protection And Control Scheme, Including Leds, Mimic Etc. As Prescribed Below , Also Scada Complying To Iec 61850 :- 7 ( I ) Rated Voltage / Maximum Operating Voltage - 36 Kv, ( Ii ) Rated Power Frquency Withstand Voltage 70 Kv, ( Iii ) Rated Lighting Impulse Withstand Voltage 170 Kv, ( Iv ) Rated Frequency 50 Hz, ( V ) Rated Short Circuit Making Current 80 Ka, ( Vi ) Rated Short Time Withstand Current 31.5 Ka, ( Vii ) Rated Duration Of Short Circuit 3 Sec, ( Viii ) Rated Opening Time = 45 M Sec, ( Ix ) Rated Break Time = 60 M Sec, ( X ) Rated Auxiliary Voltage 110 V Dc. ( Xi ) Gis Vaccum Interruter Main Numerical Relays & Meters Must Be Same Make For Better Life Cycle Optimization. ( Xii ) Each Vcb Shall 02 Nos Tripping Coil. 8 ( A ) 02 X Incomer 33 Kv Gis Panel, Each Comprising Of :- 9 ( I ) 33 Kv, 630 Amp, 25Ka / 3 -Sec, Draw-Out Vacuum Circuit Breaker As Per Iec-62271-100 With Roll On Floor Type Vacuum Circuit Breaker Having 03 Nos. Vacuum Bottles Of Same Make As Of Circuit Breaker And Panel, Motorized Spring Charging Mechanism ( 230Vac ) With Integral Spring Charging Handle For Manual Charging, Associated Push-Buttons, Anti-Pumping Feature, And Associated Shunt Trip / Close Coils ( 110V Dc ) . 10 ( Ii ) Current Transformers 33 Kv 100 / 1-1 Amp, Core1: Class 0.5, 10Va, Core2: Class Ps-X - Set Of 03Nos Per Breaker 11 ( Iii ) Potential Transformers, Draw-Out Type For Easy Maintenance, 33Kv / Rt3:110V / Rt3, 50Va, Cl.0.5 With Associated Gun-Type Hrc Fuses And Mcbs For Ht / Lt Isolation - Set Of 03 Nos. 12 ( A ) Transient / Intermittent Earth Fault Protection ( B ) Phase Discontinuity Protection ( C ) Aux. Protections Incl. Trip Circuit Supervision, Circuit Breaker Failure Protection, Master Trip Etc. ( Iv ) Main, Numerical, Drawout Protection Relay ( Line Differential ) With Large Lcd Displaying Mimic Bay For On / Off Control And Monitoring Of Feeder Parameters Listed Below And Built In Disturbance Recorder Cycle. The Relay Shall Be Fully Integrated With The Feeder, Internally Capturing Feeder Statuses Incl. Breaker On, Off, Spring.Charged, Disconnector On, Off, Earth, Line-Current / Line-Voltage, Trip Circuit Healthy, Gas-Pressure Low In Breaker Chamber, Gas-Pressure Low In Busbar Chamber, Ac Supply Fail, Local-Remote Switchthe Relay Shall Have Built-In Back-Lit Lcd Screen To Show Single-Line-Diagram And Other Relevant Parameters. 13 The Relay Shall Be Communicable On Iec 61850 Goose Platform Over Double / Redundant Rj-45 / Usb / Fo Port, Having Required Protection Functions Including ( A ) Line Differential With High Set And Low Set ( Stabilized ) With Second Harmonic Restraint To Bypass Transformer Inrush. The Scheme Will Be Implemented Using Single Mode Fibre Optic Protection Communication Link Between Local And Remote Relay. Suitable Blocking Arrangement Shall Be Available To Prevent Nuisance Tripping Due To Loss Of Connection, ( B ) Over Current And Earth Fault Protection With Minimum Pickup At Low Set Of 5% And 1% Respectively, ( C ) Transient / Intermittent Earth Fault Protection, ( D ) Phase Discontinuity Protection, ( E ) Synchro-Check Between Incomer-01 And Incomer-02 14 ( V ) Flush Mounted Aux. Protection Relays Incl. ( A ) Trip Circuit Supervision Relay, ( B ) Master Trip Relay, ( C ) Sf6 Gas Pressure Low, ( D ) Tcn ( E ) Dcf ( F ) Self Supervision ( G ) Sf 6 Gas Pressure Low. ( Vi ) Metering Equipment Incl. 01 X Digital Voltmeter ( Acc.Cl.0.5 ) , 01 X Digital Ammeter ( Acc.Cl.0.5 ) , 01 X Tri-Vector-Meter ( Acc.Cl.0.5 ) . 01No. Multi-Function-Meter ( Acc.Cl.0.5 ) Shall Be Provided With Lcd Display For Measuring Current, Voltage, Power, Power-Factor And Energy-Parameters, Total Harmonic Distortion And Max. Demand Indication, Same Shall Be Communicable On Modbus Via Rs485 Port ( Vii ) Led Indications - Breaker On / Off / Trip / Spring-Charged, R-Y-B, Disconnector-On / Off / Earth, Dc Available, Ac Supply Fail 15 ( Viii ) 16 Window Annunciator With Hooter To Indicate Following Alarms :- ( A ) Sf6 Gas Pressure Low ( Busbar Compartment ) , ( B ) Sf6 Gas Pressure Low ( Breaker Compartment ) , ( C ) Dc-Fail, ( D ) Master Trip, ( E ) Trip Circuit Failure, ( F ) Inter-Tripping Fault, ( G ) Vacuum Failure ( Current Flowing Even After Cb Open ) , ( H ) Ef & Oc. The Annunciator Will Be Complete With Required Acknowledge / Test Buttons As Required ( Ix ) Control Equipment Incl. 01 X Tnc Switch For Cb On / Off, 01 X Local-Remote Selector Switch, Push-Button For Disconnector On / Off, Mcbs For Ac / Dc Isolation As Required 16 ( X ) Other Accessories Incl. Space Heater With Thermostat For Lv Panel And Cable Chamber, 3-Pin Socket With Switch, Cfl Lamp. ( Xi ) Suitable Terminal Arrangement Along With Light Interface Unit, Patch-Cord And Associated Port For Spliced Connection With External Armoured Fibre-Optic Cable Shall Be Provided For Achieving Pilot-Wire ( Ofc ) Connection ( Line-Differential ) . 17 ( B ) 01 X Bus Coupler 33 Kv Gis Panel ( I ) 33 Kv, 630 Amp, 25 Ka / 3-Sec, Draw-Out Vacuum Circuit Breaker As Per Iec-62271-100With Roll On Floor Type Vacuum Circuit Breaker Having 03Nos. Vacuum Bottles Of Same Make As Of Circuit Breaker And Panel, Motorized Spring Charging Mechanism ( 230Vac ) With Integral Spring Charging Handle For Manual Charging, Associated Push-Buttons, Anti-Pumping Feature, And Associated Shunt Trip / Close Coils ( 110V Dc ) . ( Ii ) Current Transformers 33 Kv 100 / 1-1 Amp, Core1: Class 0.5, 10Va, Core2: Class Ps-X - Set Of 03 Nos Per Breaker ( Iii ) Main Protection Relay Shall Be A Numerical Drawout Ied Relay ( Should Be Gis Manufacturers Own Make ) Communicable On Iec 61850 Goose Platform Over Double / Redundant Rj-45 / Usb / Fo Port And Hsr Complaint With Programmable Min 14 Digital Input, Min 10 Digital Outputs, 11 Front Led , Large Dynamic Display , Microprocessor Based Protection Scheme For Detecting, Indicating And Tripping The Breaker On Various Faults Like ( A ) Over Current+ Earth Fault Protection For Ht / Lt Side. The Relay Shall Have Complete Bay Control Features Incl. Large Lcd Display For Displaying Feeder Sld ( Position Indication ) , Integrated On / Off Control Function, Three Phase Current Measurement, Disturbance Recorder, Event Log And Fault Record With Non-Volatile Memory, Self-Supervision.The Relay Shall Have Sufficient Binary Inputs And Outputs To Receive And Issue External Commands As Listed Separately. However More Di & Do May Be Provided In Order To Fulfill The Scheme Requirement For Scada Compatibilty. 18 The Relay Shall Be Fully Integrated With The Feeder, Internally Capturing Feeder Statuses Incl. Breaker On / Off / Spring.Chrgd, Line-Current, Sf6 Gas Pressure Low ( Busbar Compartment ) , Sf6 Gas Pressure Low ( Breaker Compartment ) , Master Trip, Trip Circuit Failure ( From Tcs Relay ) , Vacuum Failure ( Current Flowing Even After Cb Open ) And Display Locally On A Built-In Back-Lit Lcd Screen As A Single-Line-Diagram With Parameters As Advised ( I ) Manometer In Each Gas Chamber. 19 ( Ii ) Led Indications - Breaker On / Off / Trip / Spring-Charged, R-Y-B, Disconnector-On / Off / Earth, Dc Available ( Iii ) 16-Window Annunciator With Ackn / Test / Reset Push Button And Hooter To Indicate Following Alarms :- ( A ) Sf6 Gas Pressure Low ( Busbar Compartment ) , ( B ) Sf6 Gas Pressure Low ( Breaker Compartment ) , ( C ) Local Master Trip, ( D ) Trip Circuit Failure, ( E ) Vacuum Failure ( Current Flowing Even After Cb Open ) ( Iv ) Control Equipment Incl. 01 X Tnc Switch, Mcbs For Ac / Dc Isolation As Required ( V ) Other Accessories Incl. Space Heater With Thermostat For Lv Panel And Cable Chamber, 3-Pin Socket With Switch, Led Lamp ( Vi ) Soft Ware For Relay And Cable. ( Vii ) Panel Shall Be Offered With Digital Ammeter And Selector Switch ( Viii ) The Connection Between Bus Coupler And Riser Must Be Inside Gas. ( Ix ) Vaccuum Interrupter And Gis Panel Should Be Of Same Make. 20 ( C ) 02 Nos. Outgoing 33Kv, 630A, 25 Ka Vacuum Circuit Breaker Arrangement Having Motorized Spring-Charging ( Aux: 230Vac ) , And Continuous Duty Tripping / Closing ( Aux: 110Vdc ) With Bottom Cable Entry Each Comprising Of ( I ) Current Transformers 33 Kv 100-50 / 1-1 Amp, Core1: Class 0.5, 10Va, Core2: Class Ps-X - Set Of 03Nos. 21 ( Ii ) Main Protection Relay Shall Be A Numerical Drawout Ied Relay ( Line Differential ) Communicable On Iec 61850 Goose Platform Over Double / Redundant Rj-45 / Usb / Fo Port, Microprocessor Based Protection Scheme For Detecting, Indicating And Tripping The Breaker On Various Faults Like ( A ) Line Differential +Over Current+ Earth Fault Protection For Ht / Lt Side. The Relay Shall Have Complete Bay Control Features Incl. Large Lcd Display For Displaying Feeder Sld ( Position Indication ) , Integrated On / Off Control Function, Three Phase Current Measurement, Disturbance Recorder Cycle, Event Log And Fault Record With Non-Volatile Memory, Self-Supervision.The Relay Shall Have Sufficient Binary Inputs And Outputs To Receive And Issue External Commands As Listed Below :- 22 The Relay Shall Be Fully Integrated With The Feeder, Internally Capturing Feeder Statuses Incl. Breaker On / Off / Spring.Chrgd, Line-Current, Sf6 Gas Pressure Low ( Breaker Compartment ) , Master Trip, Trip Circuit Failure ( From Tcs Relay ) , Vacuum Failure ( Current Flowing Even After Cb Open ) And Display Locally On A Built-In Back-Lit Lcd Screen As A Single-Line-Diagram With Parameters As Advised ( Iii ) Metering Equipment Incl. 01 X Digital Ammeter ( Acc.Cl.0.5 ) , 01No. Multi-Function-Meter ( Acc.Cl.0.5 ) Shall Be Provided With Lcd Display For Measuring Current, Voltage, Power, Power-Factor And Energy-Parameters, Total Harmonic Distortion And Max. Demand Indication, Same Shall Be Communicable On Modbus Via Rs485 Port 23 ( Iv ) Led Indications - Breaker On / Off / Trip / Spring-Charged, R-Y-B, Disconnector-On / Off / Earth, Dc Available ( V ) 16-Window Annunciator With Ackn / Test / Reset Push Button And Hooter To Indicate Following Alarms :- ( A ) Sf6 Gas Pressure Low ( Busbar Compartment ) , ( B ) Sf6 Gas Pressure Low ( Breaker Compartment ) , ( C ) Local Master Trip, ( D ) Trip Circuit Failure, ( E ) Ef & Oc ( F ) Dc Fail. ( Vi ) Control Equipment Incl. 01 X Tnc Switch, Mcbs For Ac / Dc Isolation As Required ( Vii ) Line Feeder Shall Have Line Differential Protection Inbuilt In The Relay. Transformer Feeder Shall Have Transformer Differential Protection In Built In Relay. ( Viii ) Each Gas Filled Compartment Shall Have Manometer. ( Ix ) Aux Relay For Wti, Oti, Bucholz Alam & Trip ( Only For Outgoing Transformer Feeder ) ( X ) Self Powered Wirelwss Thermal Sensor To Be Provided On Cable Termination. Sensor Shall Be Supplied With Necesary Software / Hardware To Communicate With Existing Scada System. ( Xi ) Quoted Rate Shall Deemed To Inclusive Of Sitc Of Gis Oem Recommende Touch Proof Termination Kit Suitable For Gis Panel. 24 Dismantilling Of Existing 33 Kv , 1250 Amp Gis Panel ( Abb ) From Nsb-Ii Sub Stn Carefully And Shifting To Shankar Vihar Substation Including Erection, Testing, Commissioning Of The Panel With Existing Gis Panel In All Respect I.E. Cable Termination Kit Supply , Installation, Commissionig , Testing , Calibration Properly With Existing 33 Kv Gis Panel Scheme Wiring Addition Alteration Etc For Smooth Execution And Coupling With The Help Of AbbS Service Team. Complete All As Directed And Specified.Note:- ( I ) All Rates Quoted Shall Be Include The Modification Of All Technical / Software / Relay Configuration To Existing 33 Kv Gis Panel Calibration With Existing System To The Up System And Down Stream Grids For Discrimination Chat / Tripping Against Faults / Over Currents / Earth Faults / Ofc Based Differential Protection Etc. ( Ii ) Rate Quoted Include The Cost Of Necessary Modification To The Existing Floor / Cable Trenches / Civil Work For Installation Of 33 Kv Gis Panel 25 Supply, Installation, Commissioning , Design, Engineering, Manufacture, Inspection, Painting Andtesting Complete With All Accessories Of Transformer Of Capacity 2.5 Mva Step Down, Outdoor Floor Mounted, Double Copper Wound, 3 Phase, 50 Hz, Ac, Including All Standard Acessories As Per Latestis , Oilimmersed, Knan ( Natural Ester ) Confirming To Is-2026, Most Economical Losses External Cooling Tubes / Radiator Cores Type Having No Voltage Ratio 33000 / 11000 Volts, Impedance % Of 6.25 ( Corresponding To Principal Tapping ) Winding Delta Connecting On Primary Side ( Hv Side ) And Star Connected On Secondary Side ( Lv Side ) In Accordance With Vector Symbol Dyn11 ( Vector Group ) With Neutral Brought Out On Lv Side And Looping On Hv Side For Continious Output So As To Alter / Vary Secondary Voltage By ( + ) 5 To ( - ) 15% In 16 Equal Steps Of 1.25% To Be Changed By Means Of ( Oltc ) On Load Tap Changerof Make Ctr / Olg With Local / Remote Opertion Features Along With Rtccpanel With Avr Relayfor Auto / Manual Operation, Cable End Boxwith Rated Copper Bus Bars / Bimatallic Connectors Shall Be Provided For The Transformer On Both Ht And Lt Side For Connecting 33 Kv Ht 3 Core Cable Of Size 185 Sqmm On Ht Side And Single Core Six Runs Of 300 Sqmm 11Kv Ht Cable On Lt Side. Avr Should Be Scada Compatiabilty And Hv / Lv Orientation 180 Degree 26 Transformer Shall Be Of Boltless Core Design. Transformer Shall Be Double Wound, Core Type With Low Loss, Non Ageing, High Permeability Prime Grade, Crgo With M4 Grade Or Better, Perfectly Insulated And Clamped To Minimize Noise And Vibrations, Core Shall Be Purchased Directly From Manufacturer Of Core Or From Their Accredited Marketing Network And Not Through Any Agent. Before Placing Order For Procurement Of Transformer, The Contractor Shall Submit The Credentials In Respect Of The Manufacturer Ofcore And Transformer Shall Be Procured Only After Approval From Ge In Respect Of Name Of Manufacturer Of Transformer As Well As Manufacturer Of Core. The Limit Of Termperature Rise After Continous Full Load Runs As Specified In Is / Iec 60076 Shall Be Suitably Adjusted To Suit The Ambient Temperature Of Maximum 50 Degree Celsius Prevailing At Site All As Specified And Directed Including Having Following Characteristics Complete All As Specified And Directed. 27 The Transformer Shall Confirm To The Latest Edition Of Applicable Standard As Follows :- ( I ) Is-2026, For Tests And Tolerance Of Guarnteed Particulars, ( Ii ) Is-3639 For Fitting And Accessories ( Iii ) Is-2099 For Bushing >1000V ( Iv ) Is-7421 For Bushing <1000V ( V ) Is-1271 For Electrical Insulation Classified By Thermal Stability 28 ( A ) Hv / Lv Winding Electrolytic Copper 99.9% Purity 29 ( B ) Insulation Levelkvp ( I ) Hv-170 ( Ii ) Lv-70 30 ( C ) Insulation Level ( Power Frequency With Stand Kvrms ) ( I ) Hv 75 ( Ii ) Lv-28 31 ( D ) Temperature Raise For The Transformer Should Be 50 / 55 Deg.C ( Oil / Winding Temp ) At Av. Ambient Temperature Of 50C ( E ) Noise Level For Offered Transformer Will Be As Per Nema Tr1 Only ( F ) Over Loading Of The Transformer Should Be Of As Per Is 6600 Only ( G ) Transformer Shall Be Of Class H Insulation ( H ) Primary Painting Of Zinc Phosphate. ( I ) Tank Pressure, Vaccum Witstand Capability & Minimum Clearances Should Be As Per Cbip Manual. ( J ) Neutral Ct 150 / 1 Ps Class To Be Provided 32 % Efficiency At 75Deg C / Unity P.Fa ) At 100% Load-------98.87B ) At 75% Load----------99.07C ) At 50% Load--------99.23% Regulation At Full Loada ) At Unity Pf---------1.19B ) At 0.8 Pf -----------4.60 33 Note: ( I ) Rate Quoted Includes The Cost Of Transformer , Rcc Baffel Wall As Per Electricity Safety Rule From Gl With Proper Earth Work Between The Both Transformers, Rcc Foundation Designed As Per The Oem Recommendation Based On The Soil Conditions Of The Delhi Canttaf Muesuim Site ( Ii ) Rate Quoted Includes The Cost Of Necessary Power / Control Cables For Operation Of Oltc, Prv Limit Switches , Wti , Oti , Double Floatbucholz Relayfrom Rtcc Panel In Side Substation Buildingto Transformer ( Iii ) Transformer Shall Be Brought Site Only After Approval Of Gtp Drawings And Only After Completion Of Installation Of 33Kv Gis Panels And Laying Of 33Kv Cables I.E After Completion Of 50% Of The Work At Siteto Avoid Ideal Laying / Ingress Of Moisture / Corrossionto Transformer At Site Which Detoriates The Life / Warranty And Service Of The Transformer ( Iv ) Testing & Commissioning Of Transformer Shall Be Carried Out In The Presence Of Oem At Site. ( V ) Oem Of Power Transformer Must Have In House Nabl Accredited Lab. 34 Supplying, Installing, Testing And Commissioning Of Indoor Arc Flash Protected Draw-Out With Roll On Floor Type Gis Panel , Rated For 11Kv, 630 Amp, 25Ka / 3-Sec, Comprising Of 02 X Incomming +01 Bus Coupler+01 Bus Raiser+02 Out Going Vcb Panels Confirming To Iec 62271-200, And Is 13118, Accessibility Class Lsc2b-Pm Class, Comprising Of 630 Amp, Continuous Ratedinsulated Copperbusbarsand Droppers In All Bus / Breaker / Adaptor And Cable Chambers , 02 Nos. Rack-In-Rack-Out Handles, Structure Made From Aluzinc / Gi / Powder Coated Crcasheets To Prevent Corrosion And Rusting.The Complete Panel Incl. Ht And Lt Chamber With Frls Wiring And Acessoriesshall Be Manufactured By Approved Oem At Its Own Mancufacturing In House Facility, And Same Will Be Verified Via Stage / Final Inspection. System House Integrator / Channel Partner Products Are Not Accepted .The Offered Panel Shall Be Type Tested For Internal Arc 25 Ka For 1 Sec With Aflr Classification Make Of The Vcb, Panel, Relay And Meters Shall Be Of The Same Make / Oem 35 ( A ) 02 X Incomer Panel, Each Comprising Of :- ( I ) 11Kv, 630Amp, 25Ka / 3-Sec, Draw-Out Vacuum Circuit Breaker As Per Iec-62271-100. Vacuum Circuit Breaker Having 03Nos. Vacuum Bottles Of Same Make As Of Circuit Breaker And Panel, Motorized Spring Charging Mechanism ( 230Vac ) With Integral Spring Charging Handle For Manual Charging, Associated Push-Buttons, Anti-Pumping Feature, And Associated Shunt Trip / Close Coils ( 110Vdc ) . 36 ( Ii ) Current Transformers 11Kv, 300-150 / 1-1-1, Core3: Class 5P10, 5Va, Core2: Class 0.5, 5Va - Set Of 03Nos. ( For Measuring, Relaying And Transformer Differential ) Core 1 :Ps For Ref ( Iii ) Potential Transformer ( Applicable For Incommer As Line Pt ) :Floor Rolled / Cb Trolley Mounted Drawnout Type 11Kv / 110V / 110V, Core 1: 0.5 , 20 Va Core2: 3P 20 Va 04 Pt Must Not Be Panel Top Mounted. 37 ( Iv ) Mainprotection Relay Shall Be Numerical Ied Relay Confirming To Iec60255, Microprocessor Based Protection Scheme For Tripping The Breaker On Various Faults Like ( A ) Over-Current Or Earth-Fault In Any Of The Three Phases, ( B ) Circuit-Breaker-Failure Alarm, 38 ( C ) Interpanel Tripping / Blocking Signals Via Goose Based Peer-To-Peer Communication, On Iec61850 Protocol. ( D ) Integrted Arc Flash Protection With Current And Light Sensingthe Relay Shall Be Communicable On Iec 61850 Goose Platform Over Double / Redundant Rj-45 / Usb / Fo Port, And Fully Integrated With The Feeder, Internally Capturing Feeder Statuses Incl. Various Status, Line-Current, Breaker On / Off / Spring.Chrgd, Trip Circuit Failure ( From Tcs Relay ) , Local-Remote Etc. And Display Locally On A Built-In Back-Lit Lcd Screen With Mimic As A Single-Line-Diagram With Current Measurements And Suitably Labelled Status Leds. ( E ) Over And Under Voltage & Ref Protection Shall Be Given For Outgoing Feederrelay Setting Should Be Possible Through Inbuilt Software Or Through Addtional Software Supplied By The Relay Manufacturer. 39 ( Iv ) Metering Equipment Including:- ( A ) 01 X Digital Voltmeter ( Acc.Cl.0.5 ) , 01 X Digital Ammeter ( Acc.Cl.0.5 ) , ( B ) 01No. Multi-Function-Meter ( Acc.Cl.0.5 ) Shall Be Provided With Lcd Display For Measuring Current, Voltage, Power, Power-Factor And Energy-Parameters, Total Harmonic Distortion And Max. Demand Indication, Same Shall Be Communicable On Modbus Via Rs485 Port. 40 ( V ) Led Indications - ( A ) Breaker On / Off / Trip / Spring-Charged, ( B ) Trip Circuit Healthy 41 ( Vi ) 08-Window Annunciator With Hooter To Indicate Following Alarms :- ( A ) Oc Trip, ( B ) Ef Trip ( C ) Trip Circuit Failure, ( D ) Inter-Tripping Fault, The Annunciator Will Be Complete With Required Acknowledge / Test Buttons As Required 42 ( Vii ) All Multi-Function-Meters Shall Be Connected In A Modbus Loop Terminating Into 01 No. Modbus-To-Tcp / Ip Converter To Be Provided For Sending Data To Scada Console Via Networking Switch. 43 ( Viii ) Control Equipment Incl. ( A ) 01 X Tnc Switch, ( B ) 01 X Emergency Trip Push Button, ( C ) 01 X Local / Remote Switch, ( D ) Mcbs For Ac / Dc Isolation ( E ) Heater Switch With Thermostat - 01No. ( F ) 3-Pin Socket With On / Off Switch - 01No. ( G ) Led Lamp With On / Off Switch - 01No. 44 ( Ix ) Flush Mounted Auxillary Protection Relays Incl. ( A ) Trip Circuit Supervision Relay, ( B ) Master Trip Relay, 45 ( B ) 01 X Bus Coupler Panel With Raiser, Each Comprising Of :- ( I ) 11Kv, 630 Amp, 25Ka / 3-Sec, Draw-Out Vacuum Circuit Breaker As Per Iec-62271-100With Roll On Floor Type Vacuum Circuit Breaker Having 03Nos. Vacuum Bottles Of Same Make As Of Circuit Breaker And Panel, Motorized Spring Charging Mechanism ( 230Vac ) With Integral Spring Charging Handle For Manual Charging, Associated Push-Buttons, Anti-Pumping Feature, And Associated Shunt Trip / Close Coils ( 110V Dc ) . 46 ( Ii ) Current Transformers 11Kv, 300-150 / 1-1-1, Core3: Class 5P10, 5Va, Core2: Class 0.5, 5Va - Set Of 03Nos. ( For Measuring, Relaying And Transformer Differential ) Core 1 :Ps For Ref 47 ( Iii ) Main Protection Relay Shall Be Numerical Ied Relay Confirming To Iec60255, Having 04Pt Inputs With Microprocessor Based Protection Scheme For Tripping The Breaker On Various Faults Like ( A ) Synchronism And Energizing Check Before Bus-Coupler Closing To Prevent Un-Syncronized Mixing Of Supplies ( B ) Circuit-Breaker-Failure Alarm. ( C ) Circuit-Breaker-Failures And Interpanel Tripping / Blocking Signals Via Goose Based Peer-To-Peer Communication, On Iec61850 Protocol. The Relay Shall Be Fully Integrated With The Feeder, Internally Capturing Feeder Statuses Incl. Various Status, Bus-Voltage And Display The Same Locally On A Built-In Back-Lit Lcd Screen With Mimic As A Single-Line-Diagram With Power & Frequency Measurements And Suitably Labelled Status Leds.Relay Setting Should Be Possible Through Inbuilt Software Or Through Addtional Software Supplied By The Relay Manufacturer. 48 ( Iv ) Led Indications - ( A ) Breaker On / Off / Trip / Spring-Charged ( B ) Trip Circuit Healthy 49 ( V ) Control Equipment Incl. :- ( A ) 01 X Tnc Switch, ( B ) 01 X Local / Remote Switch, ( C ) 01 X Emergency Trip Push Button, ( D ) Mcbs For Ac ( E ) Mcbs For Dc ( F ) Heater Switch With Thermostat - 01 No. ( G ) 3-Pin Socket With On / Off Switch - 01 No. ( H ) Led Lamp With On / Off Switch - 01 No. 50 ( Vi ) Flush Mounted Auxillary Protection Relays Incl. ( A ) Trip Circuit Supervision Relay, ( B ) Master Trip Relay, 51 ( Vii ) 08-Window Annunciator With Hooter To Indicate Following Alarms :- ( A ) Trip Circuit Failure, ( B ) Inter-Tripping Fault, ( C ) Synchro-Check. ( D ) Pt Fuse Failurethe Annunciator Will Be Complete With Required Acknowledge / Test Buttons As Required 52 ( C ) 02 X Outgoing Panel, Each Comprising Of :- ( I ) 11Kv, 630Amp, 25Ka / 3-Sec, Draw-Out Vacuum Circuit Breaker As Per Iec-62271-100. Vacuum Circuit Breaker Having 03Nos. Vacuum Bottles Of Same Make As Of Circuit Breaker And Panel, Motorized Spring Charging Mechanism ( 230Vac ) With Integral Spring Charging Handle For Manual Charging, Associated Push-Buttons, Anti-Pumping Feature, And Associated Shunt Trip / Close Coils ( 110 V Dc ) . 53 ( Ii ) Current Transformers 11Kv, 300-150 / 1-1-1, Core3: Class 5P10, 5Va, Core2: Class 0.5, 5Va - Set Of 03Nos. ( For Measuring, Relaying And Transformer Differential ) Core 1 :Ps For Ref 54 ( Iii ) Main Protection Relay Shall Be Numerical Ied Relay Confirming To Iec60255, Having 04Ct Inputs With Microprocessor Based Protection Scheme For Tripping The Breaker On Various Faults Like ( A ) Over-Current Or Earth-Fault In Any Of The Three Phases, ( B ) Circuit-Breaker-Failure Alarm, ( C ) Interpanel Tripping / Blocking Signals Via Goose Based Peer-To-Peer Communication, On Iec61850 Protocol. ( D ) Integrted Arc Flash Protection With Current And Light Sensing. ( E ) Tranformer Protection ( Marshalling Box And Buchhloz Relay ) .The Relay Shall Be Communicable On Iec 61850 Goose Platform Over Rj-45 / Usb / Fo Port, And Fully Integrated With The Feeder, Internally Capturing Feeder Statuses Incl. Various Status, Line-Current, Breaker On / Off / Spring.Chrgd, Trip Circuit Failure ( From Tcs Relay ) , Local-Remote Etc. And Display Locally On A Built-In Back-Lit Lcd Screen With Mimic As A Single-Line-Diagram With Current Measurements And Suitably Labelled Status Leds.Relay Setting Should Be Possible Through Inbuilt Software Or Through Addtional Software Supplied By The Relay Manufacturer. 55 ( Iv ) Metering Equipment Including:- ( A ) 01 X Digital Voltmeter ( Acc.Cl.0.5 ) , 01 X Digital Ammeter ( Acc.Cl.0.5 ) , ( B ) 01No. Multi-Function-Meter ( Acc.Cl.0.5 ) Shall Be Provided With Lcd Display For Measuring Current, Voltage, Power, Power-Factor And Energy-Parameters, Total Harmonic Distortion And Max. Demand Indication, Same Shall Be Communicable On Modbus Via Rs485 Port. 56 ( V ) Led Indications - ( A ) Breaker On / Off / Trip / Spring-Charged, ( B ) Trip Circuit Healthy 57 ( Vi ) 08-Window Annunciator With Hooter To Indicate Following Alarms :- ( A ) Oc Trip, ( B ) Ef Trip ( C ) Trip Circuit Failure, ( D ) Inter-Tripping Fault, The Annunciator Will Be Complete With Required Acknowledge / Test Buttons As Required 58 ( Vii ) Control Equipment Incl. ( A ) 01 X Tnc Switch, ( B ) 01 X Emergency Trip Push Button, ( C ) 01 X Local / Remote Switch, ( D ) Mcbs For Ac / Dc Isolation ( E ) Heater Switch With Thermostat - 01No. ( F ) 3-Pin Socket With On / Off Switch - 01No. ( G ) Ledlamp With On / Off Switch - 01No. 59 ( Viii ) Flush Mounted Auxillary Protection Relays Incl. ( A ) Trip Circuit Supervision Relay, ( B ) Master Trip Relay, 60 Note For Item 08 ( I ) Cost Of Construction Of Foundation As Per Manufacturer Design, Including Foundation Frame ( Supplied By Oem ) , Channels Etc. For Ht Panel As Required At Site Are Deemed To Be Included In The Quoted Rate. ( Ii ) Each Vcb Panel Being Floor-Mounted, Air-Insulated, Fully-Compartmentalizeds The Oem Shall Supervise And Certify The Commissioning / Charging Of Equipment. ( Iii ) Foundation Frames Shall Be Inclusive In The Scope Of Supply Of Oem. 61 ( Iv ) All Multi-Function-Meters Shall Be Connected In A Modbus Loop Terminating Into 01 No. Modbus-To-Tcp / Ip Converter To Be Provided For Sending Data To Scada Console Via Networking Switch. 62 ( V ) Necessary Cat 6 And Modbus Cabling From Panel To Rtu Panel Shall Be Provided By The Contractor With In This Scope Only. 63 ( Vii ) All Incomers And Buscouplers Will Have Suitable Schemes In Place To Prevent Mixing Of Un-Syncronized Supplies Using Line / Buspt Signals. Any Such Attempt Will Be Reported By A Suitable Alarm. This Facility Should Be Implemented Over Soft-Logic, And Can Be Disabled By Authorized Personnel Without Requiring Any On-Site Re-Wiring. ( Viii ) All Outgoing Vcbs Will Have Inter-Tripping Logic In Place To Ensure That Incomer Breaker Immediately Trips In Case Of Failure Of Opening Of Outgoing Vcb Experiencing Feeder Fault. Special And Dedicated Alarm Shall Be In Place To Issued The User. This Facility Should Be Implemented Over Soft-Logic, And Can Be Disabled By Authorized Personnel Without Requiring Any On-Site Re-Wiring. ( Ix ) Self Powered Wirelwss Thermal Sensor To Be Provided On Cable Termination. Sensor Shall Be Supplied With Necesary Software / Hardware To Communicate With Existing Scada System. 64 Supply Laying Jointing Commissioning And Testing Of Xlpe Insulated Screened, Pvc Bedded, Galvanized Steel Strip / Wire Armoured Electric Power Cable Frls Pvc Sheated ( Heavy Duty ) With Multistranded Aluminum Conductors 300 Sqmm Single Core 11 Kv ( E ) Grade With Stranded Aluminium Conductor Complete Laid In Cableducts / Trays / Trenches / Encased In Gi Pipes / Rcc / Dwc / Hdpe Pipes Complete All As Specified And Directed. 65 S&F Cable End Jointing Kit For 11 Kv Grade Cable For Indoor Type Termination Heat Shrinkable Joint Complete With Jointing Material And Accessoies Suitable For Single Core Xlpe Armoured Aluminium Conductor Cable Of Size 300 Sqmm Complete All As Specified And Directed. 66 M&L For Boring Of Holes On Any Type Of Soil Of Size 250 Mm Dia, Under Road / Pavement / Hardstanding By Trenchless Technology Using Ultra Sound Technique And Necessary Machine Including Material And Labour For Hdpe Pipe Of 200 Mm Dia Suitable For 04 Kg / Sqcm Working Pressure, Wall Thickness Of Pipe Not Less Than 6.5 Mm For 33 Kv Cable Complete All As Specified And Directed. 67 Note: For Item No 11 ( I ) The Contractor Will Be Responsible For Taking Permission From Appropriate Authority I.E. Nhai / Igl Or Other Units , If Needed, For Above Said Work. ( Ii ) Depth Of Trench Less Shall Not Less Than 2 Mtr From Ground Level Unless Other Wise Specifed Due To Site Requirement And Contractor Has To Maintain The Depth Of Trenchless Up To 4 Mts From Ground Level If Required As Per Site Conditionsall Rates Quoted Shall Be Demeed To Be Included To Maintain The Trench Less Depts As Directed During Exection To Avoid Damages To The Existing Services ( Iii ) The Cost Quoted Is Deemed To Be Inculded For Repiars / Rectification For Damages Done To The Existing Elecrtical / Comminication And Water Supply System / Sewage Systemduring Execution Of Work ( Iv ) Hdpe Pipe 40 Mm Dia ( Item No 43 Below ) Is Also Passing Along With 200 Mm Dia Hdpe Pipe Through Same Bore. ( V ) No Extra Cost To Be Paid For Passing Of Hdpe Pipe. 68 M&L For Excavation In Trenches, N Exc 1.5M Wide And N. Exc 1.5 M In Depth And Getting Outfor Laying Of Htcable / Ofc / Grid Mating Etc Exc 10 Sq M On Plan And Getting Out Complete All As Specified And Directed. 69 All As Per Item No 12 ( Here-In-Before ) But In Hard Rocks. 70 S&F Gi Pipe ( Light Grade ) With Necessary Accessories / Fittings For Cable Protections / Pole For Crossing Of Culverts / Nallah / Of Size 200 Mm Dia Complete All As Specified And Directed. 71 M&L For Returing / Filling In, Including Spreading, Levelling, Watering And Well Ramming In Layers Not Exc 25 Cm In Soft / Loose Soil Complete All As Specified And Directed. 72 M&L For Removing Of Excavated Material N Exc. 50M And Depostiting Where Directed At A Level N Exc. 1.5M In Soils Complete All As Specified And Directed. 73 M & L Forsand Cushioning To Underground Pvc Cable Inclpunning Down Of Sand Layer All As Specified And Directed. Note :- For Measurement Purpose Only Punned Sand Shall Be Measured & Paid. 74 Supply & Laying Reinforced Precast Concrete Cable Cover Class Ehv Type 1 With Peak Size 450 Mm X230mmx50mm In Trenches For Protection To Under Ground Cable Complete All As Specified And Directed 75 Supply & Laying Un- Reinforced Precast Concrete Cable Cover Class Hvp Type 1 With Peak Size 300 Mm X180mmx40mm In Trenches For Protection To Under Ground Cable Complete All As Specified And Directed 76 S&F Screw Bolts ( Machine Made ) With Hexagonal Or Square Heads At One End And Screwed The Other Each Screw To Be Fitted With One Washers And One Hexagonal Or Square Nut Length Of Bolts N.Exc 5Cm And Dia Of Shank 10Mm All As Specified And Directed. 77 M&L For Cement Concrete 1:3:6 Type C-2 ( Using20mm Graded Crushed Stone Aggregate ) As In Foundation Filling And Mass Concreteas In Channel / Drains Complete All Asspecified & Directed. 78 Excavation In Post Holes N.Exc 0.5 Cum Each Getting Out, Returning Filling In And Ramming Earth In Layers N.Exc 25Cm Watering And Removing Surplus Soil To A Distance N.Exc 50M And Making Good Surface In Soft / Loose Soil Complete All As Specified And Directed. 79 S&F Galvanised 2 Strand, Steel Barbed Wire 2.24Mm Dia Barbed With 2Mm Dia Barbs At 75Mm Spacings And Straining And Fixing To Any Type Of Standard Rails, Straining Bolts, Including Securingor Tying At Crossings With And Provision Of Galvanised Mild Steel Wire, Staples Or Steel Pins Etc Etc As Directed ( Each Line Wire To Be Measured ) Incl Taking Down Old Wire Etc Complete All As Specified And Directed 80 Supply Only Chain Link Ms Galvanised Fencing, Any Size Or Type Etc Complete All As Specified And Directed. 81 Fixing Only Chain Link Fencing Including Line Wires, Any Mesh , Size And Type To Any Type Of Standards , Rails , Straining Bolts, Etc. Including Provision Of Binding Wire Complete All As Specified And Directed. 82 M&L For Two Coats Of Synthetic Enamel Paint Over A Coat Of Primer Incl Preparation Of New Steel Surfaces Of Any Description Over 10Cm Girth Or Width Complete All As Specified And Directed. 83 S&F In Ms Work Such As In Posts And Struts In Fencing Including Cutting Tops To Shape As Directed, Drilling Holes, Notching For Wire, Etc.Flat Iron Fillets ( For Securing Wire Mesh Etc. ) Including All Necessary Drilling, Bolting Or Riveting, Etc And Similar Work Conforming To Fe 290 Gde E-165 All As Specified And Directed. 84 S&F 12Mm Dia Round Tmt Bars As In Fencing, Cut To Length Fixing With Posts / Fencing, Bindingsecuring With Clips Etc All As Specified And Directed 85 M&L For Preparation Of New Steel Surfaces Not.Exc 10Cm Width Or Girth And Applying Two Coats Of Synthetic Enamel Paint Overa Coat Of Red Oxide Primer, Complete All As Specified And Directed. 86 Supply And Fix Cable Route Indicator Made Of Rcc ( Nominal Mix ) Type Bo 1:2:4 ( 12.5 Mm Graded Stone Aggregate ) With 8 Mm Tmt Bar 1.5 M Height X 60 Cm Wide X 10 Mm Thick Tapered On Top Visible Above Ground Duly Painted With Synthetic Enamel Paint Of Yellow Colour Base And Letters With Black Paint. The Description For Writing For Ht Cable 33000 Volts Will Be Given By Engr-In-Charge Complete All As Specified And Directed. 87 M&L For Danger Notice Board Of 1.6 Mm Thick Mild Steel, Vitreous Enamelled White With Letters, Figures And Conventional Skull And Bones In Signal Red Colour And Fixed With Ms Clamps, Bolts And Nuts Of Approved Size For Ht 25 X 20 Cm Size Complete All As Specified Anddirected. 88 M&L For Erection Of Steel Tubular Swan Neck Pole For Security Lights , Type 410-Sp-31, 9.0 Mtr Long Painted With Two Coats Of Synthetic Aluminium Enamel Paint Over A Coat Of Red-Oxide Primer, Making 03 Nos Radium Strip On Pole Of Size 150Mm Height From Gl To Pole Height 1.0 Mtr Complete All As Specified And As Directed ( Note:- Excavation, Pcc Work Shall Be Measured And Paid Separately ) 89 M&L For Complete Fixing Ofenergy Efficientled Street Lights Fittings Of 90 Watt Capacity , 220 Volt , 50 Hz, Ip 65 / 66Pole Mountedincluding Pole Box And Connecting Wire Of 1.5 Sqmm 3 Core From Pole Box To Fitting All As Specified And Directed. 90 M&L For Pcc In Foundation Filling And Mass Concrete Type C2 ( 1:3:6 ) Using 40 Mm Graded Aggregate Complete All As Specified And Directed 91 M& L For Pcc Type B1 ( 1:2:4 ) Using 20 Mm Graded Stone Aggregate For Pole Coping Complete All As Specified And Directed 92 M&L For Bore Earthing In Hard Rock Of 150 Mm Dia, Depth 30 Mtr Below Ground Level Using Earth Electrode 50 Mm Dia Gi Pipe Medium Grade Duly Drilled Hole Of 12 Mm Dia 115 Cm C / C On Both Side Of The Pipe Including Lowering In Bore Well Upto The Depth Of 29 Mtr And One Mtr Above The Ground Level The Pipe Electrode Should Be Filled Around Commercial Salt Charcoal Dust / Breeze And Magnesium Phosphate Of 30 Cm Layer Each Upto The Fiull Length Of Pipe. The Bore Well Should Have 06 Mtr Of Length 150Mm Dia Ms Pipe For Protection Of Bore Well Welding Of Gi Strip 50 X 6 Mm On Earth Electrod Gi Pipe 50 Mm Dia Upto The 20 Mtr Below Ground Level 15 Mtr From The Bore Well To Test Point. Necessary Water Connection By Gi Steel Tubing Light Grade10 Mm Dia Complete All As Directed By Engineer-In-Charge. Note :- Gi Strip More Than 30 Mtr Will Be Measured And Paid Separetely. 93 M&Lfor Laying , Fixing Of Gi Strip 50 X 6 Mm With Saddle And Fixing Screw Etc Complete All As Specified And Directed. 94 M&L For Earthingwith Copper Plate Electrode 600X600x3.15 Mm Thick Buried Directly In Ground ( Earth Pit Not Less Than 2.25 M Deep Below Normal Ground Level ) With Top Edge Of The Plate Not Less Than 1.5 M Below Normal Ground Level Connected To Copper Earth Strip 20X3mm ( Up To 7.5 M In Length From Earth Plate ) By Means Of Bolts And Nuts Checknuts And Washers Of Galvanized Iron Electric Arc Welding All Joints All As Specified And Shown In Electrical Plate No 3 Of Ssr Part I Including Necessary Excavation And Earth Work In Any Type Of Soil Pcc 1:3:6 Type C1 Chamber With Pcc 1:2:4 Type B1 40 Mm Thick Cover With Ms Rod 8Mm Dia 150Mm Long Reinforcement, Watering Funnel, 40 Mm Dia Medium Grade For Protection Of Earth Electrode 20 Mm Dia For Watering Complete All As Specified And Directed And Tested On Completion Complete All As Specified And Directed. 95 M&L For Copper Strip 20 X 3 Mm With Saddle And Fixing Screw Etc Complete All As Specified And Directed. 96 M&L For Gravel Filling Of Size N.Exc 40 Mm, Deposited Spread And Levelled In Layers N.Exc 15 Cm Thick, Watered And Rammed To A True Surface Complete All As Specified And Directed. 97 S &F Fire Retardant / Extinguishing Electric Insulated Synthetic Mat Insulatica - 2000 Of 3.0Mm Thick + 10% Confirming To Bis : Doc No Et-02 ( 5440 ) Dated 30 Apr 2004, Meeting Requirement Of Is-3043, Is-5216 ( Part -I, Ii &Ii ) , Is-8437 And Iec-479 Pub-I, Tested For Breakdiwn Strength, Tensile / Elongation Ageing Properties, Insulation Resistance , Effect Of Acid, Alkaline, Diesel And Transformer Oil Leakage Current Test, Fire Test Etc, Having Minimumwidth Of 1000Mm + 20Mm Including All Allied Materials Such As Pu-Resin, Chemical Bound ( Haedener ) Special Pvc Adhesive Liquid Primer Etc Of Required Quantity To Complete The Job As Per Site Requirement Of All Voltages Not Exceeding 33 Kv System Without Ht Trolley Movement. Of Size 2 X 1 Mtr Complete All As Specified And Directed. 98 Supply, Laying, Jointing And Testing Of Armoured Optical Fibre Underground Cable, 12 Core ( Fiber ) Along With Light Interfacing Unit Laid In Trenches / Ducts / Fixed On Poles / Walls, Laid Under / Path Or Encased In Hdpe Pipe Complete All As Specified And Directed. Note : The Cost Of Joints / Splicing Deemed To Included In The Quoted Rate. 99 M&L High Density Polyethylene Pipes ( Duct For Ofc ) Of Size 40 Mm Dia ( Hdpe ) Ofpressure Rating 10 Kg / Cm2 Laid In Trenches / Bore Holes Of Road Crossing / Hard Standing For Laying Of Ofc Complete All As Specified And Directed.. 100 M&L For Splicing Work Of Optical Fibre Cable Of 6 / 12 Core Forend Connection At Fibre Optic Distribution Box Complete All As Directed. 101 S&F Patch Cords Having Any Type Of Connectors ( Sc / Lc / St / Fc ) At Both Ends As Per Site Requirement Complete All As Directed. 102 S&F Ofc 12 Liu Port Complete All As Directed. 103 Supply Installation & Commissioning Of 110V / 30A Scr Controlled Float Cum Boost Battery Charger Unit Including Battery Bank Comprising 2 Volts / 100 Ah Cells - 55 Nos Sealed Maintenance Free Battery.The Cccv Battery Charger Consisting Of Copper Wound, Air Cooled Transformer, 01 Set Single Phase Full Wave Bridge Rectifier Consisting Of Diodes And Scrs, Liberally Rated Mounted On Heat Sink And Complete With Resistor / Condenser Network For Surge Suppression.During Auto Float Mode Automatic Changeover Shall Take Place From Float Mode To Boost Mode And Vice Versa, 01 Set Of Solid State Constant Potential Controller To Stabilize The Dc Output Voltage Of The Float Cum Boost Charger, 01 No Electronic Controller, Dcdigital Ammeter, Dc Digitalvoltmeter, Potentiometer, Dc, Mcb For Reverse Battery Protection. The Charger Should Have Alarm Annunciation With Visual And Audible Alarm With Manual Reset Facility For Fuse Fail Alarm. Float Cum Boost Battery Charger And Dc Distribution Board Shall Be Housed In Powder Coated Sheet Steel Cubicle With Panels Of 1.6Mm Thickness, Louvers For Ventilation, Gland Plate Will Be Provided For Cable Entry From Bottom. The Battery Charger Shall Be Divided Into Two Compartments.The Upper Compartment Shall House The Battery Charger & Dcdb With All Necessary Controls. The Lower Compartment Shall Be Suitable For Housing The Batteries. Tech Specification Shall Be As Under:- 104 ( A ) Input Working Voltage-180 -270 Volts ( B ) Nominal Input Voltage - 230 V , Ac , 50 Hz, 1 ( C ) On Load Input Power Factor- > 0.8 ( D ) On Load Unit Watt Efficiencies-> 80% ( E ) No Load Losses Of Complete Charge-< 10% ( F ) Ripple Contents On The Load ( Rms ) = 1% To 5% ( G ) Overload - 110% For 30 Minutes And Will Give Visual Indication For Over Load Condition. ( H ) Boost Charging - 2.4 V / Cell. ( J ) Float Charging -2.15 V / Cell ( K ) Float Cum Boost Charging-Automatically Changes From One State To Another State As Per Battery Condition And Wiil Give The Visual Indication For Either Float Or Boost Based On Charging Mode. ( L ) Reverse Polarity -No Damage Will Be Caused.A Visual Indication For Reverse Polarity Will Appear With An Audio Alarm. ( M ) Short Circuit-Mcb Protection Provided. 105 Supply, Installation Of Required Equipments At Airforce Muesum, Palam Substation For Hooking Up 33Kv & 11Kv Switchgears To Shankar Vihar Ids Subattion Scada And Integartion Subsequently.Tentetive Equipments Shall Be As Follows But Not Limited To:A. 1 Nos. Serial To Tcp Converter, Rj11 / Rj45 To Serial Converter For Multifunction Meter Accessb. 1 Nos. Relay Networking Ethernet Switches: ( Loose Supply ) To Be Mounted Inside The 33Kv Or 11Kv Switchgear Panel Managed Fast / Gigabit Ethernet 19’ Switch -Each 20 Fast Ethernet Ports, With Single Aux. Supply.C. 1 Nos. Iec 61850 Compliant I / O Units For Acquisition Of Substation Miscellaneous Signals From Battery Charger, Ups Etc. – I / O Capability Up To 24 I / Od. Equipment For Rtcc Control Supported Over Modbus Control Along With Tcp Converter ( If Required ) E. Cat 6 Cable For Relay Networking Upto Ethernet Switches Forsubstation As Required.F. Ofc Cable And Its Termination From Liu To Ethernet Switch G. Intergartion Of Complete 33Kv & 11Kv Switchgear And Other Substation Equipments At Shankar Vihar Ids Substation Scada. 106 Supply And Installation Of Co2 Portable Type Fire Extinguisher Isi Marked Confirming To Is:15683 Of Capacity 4.5 Kg Complete With Delivery House Horn, Squeeze Grip Release Valve, Locking Arrangement, Operational Manaul, Braket With Screws And Sleeves Complete All As Specified And Directed. 107 Supply And Installation Of Co2 Wheel Mountedtype Fire Extinguisher Isi Marked Confirming To Is:2878 :2004Of Capacity 9 Kg Complete With Delivery House Horn, Squeeze Grip Release Valve, Locking Arrangement, Operational Manual, Braket With Screws And Sleeves Complete All As Specified And Directed.
Contract Date : 30 Aug, 2023   |   Contract Value : 4.53 Crore
Disclaimer

We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.

Tender Detail
Website https://etender.cpwd.gov.in/login.html
Quantity 0
MSME Exemption No
Tender Type Open Tender
Startup Exemption Click Here
Competitive Bidding NCB
Similar Tenders
TENDER INSIGHTS

858

Electric Tenders
Live
CLICK TO KNOW MAXIMUM WIN

Tell us about your Product / Services,

We will Find Tenders for you

🇮🇳 +91
TenderDetail
Loading tenders