TDR : 57103315
Central Public Works Department

Tender Brief :

Hyderabad, Telangana

Supplying, Installation, Testing And Commissioning Of Grid Interactive Roof Top Solar Photo Voltaic System At Office Cum Lab Building For CIPMC, Jeedimetla, Hyderabad.

Published: 19 Aug 2026
Opening: 31 Aug 2026
Closing: 31 Aug 2026
Amount: 16.28 Lakhs
EMD: 32568
Tender Fee: Ref. Documents


Works Bio Gas Plant Diesel Power Plants Electrical Substation Gas Power Plants Geothermal Power Plants
7
Days Left
Tender Summary / Eligibility Criteria
Supplying, Installation, Testing And Commissioning Of Grid Interactive Roof Top Solar Photo Voltaic System At Office Cum Lab Building For CIPMC, Jeedimetla, Hyderabad.
Documents Download All
17cbc9c1-4207-4283-bcde-369b493802f3
17cbc9c1-4207-4283-bcde-369b493802f3.html
DocumentsList
DocumentsList.zip
No Boq
No Corrigendum
Probable Bidders

AI engine predicts probable bidders to help you bid strategically.

MSME Exception
Explore More →
Technical
Tender involves procurement of high capacity electrical equipment including diaphragm coupling of pump & motor with 90kW capacity at 2900 RPM. The project scope includes installation, testing, commissioning and operational handover.
Previous / Similar Result
BRR : 5934570 Bids Are Invited For Supplying, installation, testing and commissioning of Grid interactive roof top solar photo voltaic power generation system including space frame complete in all respect.
Contract Date : Ref. Documents   |   Contract Value : 17.85 Lakhs
BRR : 3441109 Design , Supply , Installation , Testing And Commissioning Of 20Kwp Grid Interactive Solar Photo Voltaic ( Spv ) Based Solar Power System With Five Year Free Amc At Office Griha Nirman Bhavan Of N . H . And A . D . Board . Nashik
Contract Date : 20 Aug, 2020   |   Contract Value : 13.03 Lakhs
BRR : 1599783 Appointment Of Epc Contractor For The Design As Per Site Conditions, Erection, Testing & Commissioning Of Grid Tied Roof Top Solar Photo Voltaic ( Spv ) Power Plants, On The Roof Of Various Govt Institutions And Offices In Kattakada Legislative Assembly Constituency With A Total Installed Capacity Of 455 Kwp In Total 56 Locationincluding Operation & Maintenance Of The Plant For The First 5 Years From The Date Of Handing Over => Limited
Contract Date : 18 Jun, 2023   |   Contract Value : 2.39 Crore
BRR : 5233922 Construction Of E.M. Quarter ( G+5 ) At Btc, Kokrajhar ( 20 Units ) ( Including Civil, Electrical, Sanitary, Plumbing, Water Supply Works, Site Development, Furniture, Air Conditioner, Gym Equipment Etc. ) .”- Civil, Sanitary & Water Supply Works:1.00: Carriage Of Materials1.1: By Mechanical Transport Including Loading, Unloading And Stacking1.1.2: Earthbeyond 10 Km Upto 20 Km Per Km 2 1.1.18: Disposal Of Moorum / Building Rubbish / Malba / Similar Unserviceable, Dismantled Or Waste Material By Mechanical Transport Including Loading, Transporting, Unloading To Approved Municipal Dumping Ground For Lead Upto 10 Km For All Lifts, Complete As Per Directions Of Engineer-In-Charge. 3 2.10: Excavating Trenches Of Required Width For Pipes, Cables, Etc Including Excavation For Sockets, And Dressing Of Sides, Ramming Of Bottoms, Depth Upto 1.5 M, Including Getting Out The Excavated Soil, And Then Returning The Soil As Required, In Layers Not Exceeding 20 Cm In Depth, Including Consolidating Each Deposited Layer By Ramming, Watering, Etc. And Disposing Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M :2.10.1: All Kinds Of Soil2.10.1.1: Pipes, Cables Etc, Not Exceeding 80 Mm Dia. 4 2.16: Close Timbering In Trenches Including Strutting, Shoring And Packing Cavities ( Wherever Required ) Complete. ( Measurements To Be Taken Of The Face Area Timbered ) .2.16.1: Depth Not Exceeding 1.5 M 5 2.6: Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means Over Areas ( Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan ) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5 M, As Directed By Engineer-Incharge. 6 2.8: Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) , Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M.2.8.1: All Kinds Of Soil. 7 2.27: Supplying And Filling In Plinth With Sand Under Floors, Including Watering, Ramming, Consolidating And Dressing Complete. 8 2.28: Surface Dressing Of The Ground Including Removing Vegetation And Inequalities Not Exceeding 15 Cm Deep And Disposal Of Rubbish, Lead Up To 50 M And Lift Up To 1.5 M.2.28.1: All Kinds Of Soil 9 2.31: Clearing Jungle Including Uprooting Of Rank Vegetation, Grass, Brush Wood, Trees And Saplings Of Girth Up To 30 Cm Measured At A Height Of 1 M Above Ground Level And Removal Of Rubbish Up To A Distance Of 50 M Outside The Periphery Of The Area Cleared. 10 2.33: Felling Trees Of The Girth ( Measured At A Height Of 1 M Above Ground Level ) , Including Cutting Of Trunks And Branches, Removing The Roots And Stacking Of Serviceable Material And Disposal Of Unserviceable Material.2.33.1: Beyond 30 Cm Girth Upto And Including 60 Cm Girth 11 2.35: Diluting And Injecting Chemical Emulsion For Post-Constructional Anti-Termite Treatment ( Excluding The Cost Of Chemical Emulsion ) :2.35.1: Along External Wall Where The Apron Is Not Provided Using Chemical Emulsion @ 7.5 Litres / Sqm Of The Vertical Surface Of The Substructure To A Depth Of 300Mm Including Excavation Channel Along The Wall & Rodding Etc. Complete:2.35.1.1: With Chlorpyriphos / Lindane E.C. 20% With 1% Concentration 12 2.35.2: Along The External Wall Below Concrete Or Masonry Apron Using Chemical Emulsion @ 2.25 Litres Per Linear Metre Including Drilling And Plugging Holes Etc.:2.35.2.1: With Chlorpyriphos / Lindane E.C. 20% With 1% Concentration 13 2.35.3: Treatment Of Soil Under Existing Floors Using Chemical Emulsion @ One Litre Per Hole, 300 Mm Apart Including Drilling 12 Mm Diameter Holes And Plugging With Cement Mortar 1 :2 ( 1 Cement : 2 Coarse Sand ) To Match The Existing Floor: 14 2.35.4: Treatment Of Existing Masonry Using Chemical Emulsion @ One Litre Per Hole At 300 Mm Interval Including Drilling Holes At 45 Degree And Plugging Them With Cement Mortar 1:2 ( 1 Cement : 2 Coarse Sand ) To The Full Depth Of The Hole :2.35.4.1: With Chlorpyriphos / Lindane E.C. 20% With 1% Concentration 15 2.35.5: Treatment At Points Of Contact Of Wood Work By Chemical Emulsion Chlorpyriphos / Lindane ( In Oil Or Kerosene Based Solution ) @ 0.5 Litres Per Hole By Drilling 6 Mm Dia Holes At Downward Angle Of 45 Degree At 150 Mm Centre To Centre And Sealing The Same. 16 Cement Concrete ( Cast In Situ ) 4.1: Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level :4.1.5: 1:3:6 ( 1 Cement : 3 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 6 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) 17 4.9: Precasting And Placing In Position 125 Mm Dia Bollards 600 Mm High Of Required Shape Including Providing M.S. Pipe Sleeve 50 Mm Dia 300 Mm Long In The Bollard And M.S. Pipes 40 Mm Dia And 450Mm Long With 150X150x6mm M.S. Plate Welded At Bottom And Embedded 150Mm In Cement Concrete 1:3:6 ( 1 Cement : 3 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 6 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) , Including Necessary Excavation Of Size 250X250x450mm Deep For The Same In Bitumen / Concrete Pavement At Specified Spacing. 18 4.10: Providing And Laying Damp-Proof Course 40Mm Thick With Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 4 Graded Stone Aggregate 12.5Mm Nominal Size Derived From Natural Sources ) 19 4.12: Extra For Providing And Mixing Water Proofing Material In Cement Concrete Work In Doses By Weight Of Cement As Per ManufacturerS Specification. 20 4.14: Extra For Concrete Work In Superstructure Above Floor V Level For Each Four Floors Or Part Thereof. 21 4.17: Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 ( 1 Cement : 3 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 6 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) Over 75Mm Thick Bed Of Dry Brick Ballast 40 Mm Nominal Size, Well Rammed And Consolidated And Grouted With Fine Sand, Including Necessary Excavation, Levelling & Dressing & Finishing The Top Smooth. 22 5.1: Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level :5.1.2: 1:1.5:3 ( 1 Cement : 1.5 Coarse Sand ( Zone-Iii ) Derived From Naturalsources : 3 Graded Stone Aggregate 20 Mm Nominal Size De Rived From Natural Sources ) 23 5.2: Reinforced Cement Concrete Work In Walls ( Any Thickness ) , Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : 24 5.3: Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 ( 1 Cement : 1.5 Coarse Sand ( Zone-Iii ) : 3 Graded Stone Aggregate 20 Mm Nominal Size ) . 25 5.5A: Reinforced Cement Concrete Work In Arches, Archribs, Domes, Vaults, Shells, Folded Plate And Roofs Having Slope More Than 15° Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 ( 1 Cement : 1.5 Coarse Sand Incuding Manufactured Sand Derived From Recycled Concrete Aggregate ( Rca ) Upto 20% : 3 Graded Stone Aggregate 20 Mm Nominal Size Recycled Concrete Aggregate ( Rca ) Upto 20% ) . 26 5.8: Reinforced Cement Concrete Work In Vertical And Horizontal Fins Individually Or Forming Box Louvers, Facias And Eaves Boards Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1½:3 ( 1 Cement : 1½ Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 3 Graded Stone Aggregate 20Mm Nominal Size Derived From Natural Sources ) . 27 Form Work5.9: Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For5.9.1: Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete 28 5.9.2: Walls ( Any Thickness ) Including Attached Pilasters, Butteresses, Plinth And String Courses Etc. 29 5.9.3: Suspended Floors, Roofs, Landings, Balconies And Access Platform 30 5.9.5: Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers 31 5.9.6: Columns, Pillars, Piers, Abutments, Posts And Struts 32 5.9.7: Stairs, ( Excluding Landings ) Except Spiral-Staircases 33 5.9.9: Arches, Domes, Vaults Up To 6 M Span 34 5.9.13: Vertical And Horizontal Fins Individually Or Forming Box Louvers Band, Facias And Eaves Boards 35 5.9.16: Edges Of Slabs And Breaks In Floors And Walls5.9.16.1: Under 20 Cm Wide 36 5.9.17: Cornices And Mouldings 37 5.9.19: Weather Shade, Chajjas, Corbels Etc., Including Edges 38 5.11: Extra For Additional Height In Centering, Shuttering Where Ever Required With Adequate Bracing, Propping Etc., Including Cost Of De-Shuttering And Decentering At All Levels, Over A Height Of 3.5 M, For Every Additional Height Of 1 Metre Or Part Thereof ( Plan Area To Be Measured ) .5.11.1: Suspended Floors, Roofs, Landing, Beams And Balconies ( Plan Area To Be Measured ) 39 Steel Reinforcement:5.22: Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level.5.22.6: Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More 40 5.22A: Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level.5.22A.6: Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More. 41 5.30: Add For Plaster Drip Course / Groove In Plastered Surface Or Moulding To R.C.C. Projections. 42 5.38: Extra For R.C.C. / B.M.C / R.M.C. Work Above Floor V Level For Each Four Floors Or Part Thereof. 43 5.41: Supplying And Applying Pre Tested And Approved Water Based Concrete Curing Compound To Concrete / Masonry Surface, All As Per Manufacturer’S Specification And Direction Of Engineer-In-Charge.5.41.1: Non Pigmented Wet Curing Compound 44 5.42: Providing And Fixing Parallel Threaded Couplers Conforming To Is Code On “Reinforcement Couplers For Mechanical Splices Of Bars For Concrete Reinforcement - Specification”, To Reinforcement Bars Including Threading, Enlargement At Connection By Forging, Protecting The Prepared Reinforcement Bars And Related Operations As Required To Complete The Works Per Direction Of Engineer- In-Charge.5.42.1: Coupler For 16 Mm Diameter Reinforcement Bar 45 5.42.2: Coupler For 20 Mm Diameter Reinforcement Bar 46 5.44: Providing And Fixing Of Expansion Joint System Related With Floor Location As Per Drawings And Direction Of Engineer-In-Charge. The Joints System Will Be Of Extruded Aluminum Base Members, Self Aligning / Self Centering Arrangement And Support Plates Etc. As Per Astm B221-02. The System Shall Be Such That It Provides Floor To Floor / Floor To Wall Expansion Controlsystem For Various Vertical Localtion In Load Application Areas That Accommodates Multi Directional Seismic Movement Without Stress To ItS Components. System Shall Consist Of Metal Profiles With A Universal Aluminum Base Member Designed To Accommodate Various Project Conditions And Finish Floor Treatments. The Cover Plate Shall Be Designed Of Width And Thickness Required To Satisfy Projects Movement And Loading Requirements And Secured To Base Members By Utilizing Manufacturer’S Pre-Engineered Self- Centering Arrangement That Freely Rotates / Moves In All Directions. The Self - Centering Arrangement Shall Exhibit Circular Sphere Ends That Lock And Slide Inside The Corresponding Aluminum Extrusion Cavity To Allow Freedom Of Movement And Flexure In All Directions Including Vertical Displacement. Provision Of Moisture Barrier Membrane In The Joint System To Have Watertight Joint Is Mandatory Requirementall As Per The Manufactures Design And As Approved By Engineer -In- Charge. ( Material Shall Confirm To Astm 6063 ) .5.44.2: Floor Joint Of 150 Mm Gap 47 5.46: Providing And Fixing Of Expansion Joint System Of Approved Make And Manufactures For Various Roof Locations As Per Approved Drawings And Direction Of Engineer-In-Charge. The Joints Shall Be Of Extruded Aluminum Ase Members With, Self Aligning And Self Centering Arragement Support Plates Asper Astm B221-02. The System Shall Be Such That It Provides Watertight Roof To Roof / Roof To Corner Joint Cover Expansion Control System That Is Capable Of Accommodating Multidirectional Seismic Movement Without Stress To Its Components. System Shall Consist Of Metal Profile That Incorporates A Universal Aluminum Base Member Designed To Accommodate Various Project Conditions And Roof Treatments. The Cover Plate Shall Be Designed Of Width And Thickness Required To Satisfy Movement And Loading Requirements And Secured To Base Members By Utilizing Manufacturer’S Pre-Engineered Self-Centering Arrangement That Freely Rotates / Moves In All Directions. The Self Centering Arrangement Shall Exhibit Circular Sphere Ends That Lock And Slide Inside The Corresponding Aluminum Extrusion Cavity To Allow Freedom Of Movement And Flexure In All Directions Including Vertical Displacement. The Joint System Shall Resists Damage Or Deterioration From The Impact Of Falling Ice, Exposure To Uv, Airborne Contaminants And Occasional Foot Traffic From Maintenance Personnel. Provision Of Moisture Barrier Membrane In The Joint System To Have Water Tight Joint Is Mandatory Requirement. ( Material Shall Confirm To Astm 6063 ) .5.46.2: Roof Joint Of 150 Mm Gap 48 6.1: Brick Work With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 In Foundation And Plinth In:6.1.1: Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) 49 6.13: Half Brick Masonry With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level6.13.2 Cement Mortar 1:4 ( 1 Cement :4 Coarse Sand ) 50 6.14: Extra For Half Brick Masonry In Superstructure, Above Floor V Level For Every Four Floors Or Part Thereof By Mechanical Means. 51 6.15: Extra For Providing And Placing In Position 2 Nos 6Mm Dia. M.S. Bars At Every Third Course Of Half Brick Masonry. 52 6.38: Providing And Laying Autoclaved Aerated Cement Blocks Masonry With 100 Mm Thick Aac Blocks In Super Structure Above Plinth Level Up To Floor V Level In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) . The Rate Includes Providing And Placing In Position 2 Nos 6 Mm Dia M.S. Bars At Every Third Course Of Masonry Work. 53 8.2.2: Granite Stone Slab Colour Black, Cherry / Ruby Red8.2.2.1: Area Of Slab Upto 0.50 Sqm 54 8.3: Providing Edge Moulding To 18 Mm Thick Marble Stone Counters, Vanities Etc., Including Machine Polishing To Edge To Give High Gloss Finish Etc. Complete As Per Design Approved By Engineer-In-Charge.8.3.2: Granite Work 55 8.5: Extra For Providing Opening Of Required Size & Shape For Wash Basin / Kitchen Sink In Kitchen Platform, Vanity Counter And Similar Location In Marble / Granite / Stone Work, Including Necessary Holes For Pillar Taps Etc. Including Moulding, Rubbing And Polishing Of Cut Edges Etc. Complete. 56 8.31: Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 ( Thickness To Be Specified By The Manufacturer ) , Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. 57 8.9: Stone Tile ( Polished ) Work For Wall Lining Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Cement Slurry @ 3.3 Kg / Sqm Including Pointing In White Cement Complete.8.9.1: 8Mm Thick8.9.1.1: Raj Nagar Plain White Marble / Udaipur Green Marble / Zebra Black Marble 58 9.1: Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length ( Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately ) .9.1.3: Kiln Seasoned And Chemically Treated Hollock Wood 59 9.5: Providing And Fixing Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows, Fixing With Butt Hinges Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineer-In-Charge. ( Note:- Butt Hinges And Necessary Screws Shall Be Paid Separately ) 9.5.1: Second Class Teak Wood9.5.1.1: 35 Mm Thick Shutters 60 9.21: Providing And Fixing Isi Marked Flush Door Shutters Conforming To Is : 2202 ( Part I ) Non-Decorative Type, Core Of Block Board Construction With Frame Of 1St Class Hard Wood And Well Matched Commercial 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters:9.21.1: 35 Mm Thick Including Isi Marked Stainless Steel Butt Hinges With Necessary Screws 61 9.22: Extra For Providing And Fixing Flush Doors With Decorative Veneering Insteadof Non Decorative Isi Marked Flush Door Shutters Conforming To Is: 2202 ( Part I ) 9.22.1 On One Side Only 62 9.48: Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete.9.48.2: Fixed To Openings / Wooden Frames With Rawl Plugs Screws Etc. 63 9.70: Providing And Fixing Is : 12817 Marked Stainless Steel Butt Hinges With Stainless Steel Screws Etc. Complete :9.70.1: 125X64x1.90 Mm 64 9.74: Providing And Fixing Bright Finished Brass Tower Bolts ( Barrel Type ) With Necessary Screws Etc. Complete :9.74.1: ( 250 X 10 ) Mm 65 9.82: Providing And Fixing Bright Finished Brass Hanging Type Floor Door Stopper With Necessary Screws, Etc. Complete. 66 9.83: Providing And Fixing Aluminium Die Cast Body Tubular Type Universal Hydraulic Door Closer ( Having Brand Logo With Isi, Is : 3564, Embossed On The Body, Door Weight Upto 35 Kg And Door Width Upto 700 Mm ) , With Necessary Accessories And Screws Etc. Complete. 67 9.96: Providing And Fixing Aluminium Sliding Door Bolts, Isi Marked Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) , Transparent Or Dyed To Required Colour Or Shade, With Nuts And Screws Etc. Complete :9.96.1: 300X16 Mm 68 9.147D: Providing And Fixing Factory Made Upvc White Colour Sliding Glazed Window Upto 1.50 M In Height Dimension Comprising Of Upvc Multi-Chambered Frame With In-Built Roller Track And Sash Extruded Profiles Duly Reinforced With 1.60 ± 0.2 Mm Thick Galvanized Mild Steel Section Made From Roll Forming Process Of Required Length ( Shape & Size According To Upvc Profile ) , Appropriate Dimension Of Upvc Extruded Glazing Beads And Upvc Extruded Interlocks, Epdm Gasket, Wool Pile, Zinc Alloy ( White Powder Coated ) Touch Locks With Hook, Zinc Alloy Body With Single Nylon Rollers ( Weight Bearing Capacity To Be 40 Kg ) , G.I Fasteners 100 X 8 Mm Size For Fixing Frame To Finished Wall And Necessary Stainless Steel Screws Etc. Profile Of Frame & Sash Shall Be Mitred Cut And Fusion Welded At All Corners, Including Drilling Of Holes For Fixing HardwareS And Drainage Of Water Etc. After Fixing Frame The Gap Between Frame And Adjacent Finished Wall Shall Be Filled With Weather Proof Silicon Sealent Over Backer Rod Of Required Size And Of Approved Quality, All Complete As Per Approved Drawing & Direction Of Engineer-In-Charge. ( Single / Double Glass Panes, Wire Mesh And Silicon Sealent Shall Be Paid Separately ) . Variation In Profile Dimension In Higher Side Shall Be Accepted But No Extra Payment On This Account Shall Be Made.9.147D.2: Three Track Three Panels Sliding Window With Fly Proof Ss Wire Mesh ( Two Nos. Glazed & One No. Wire Mesh Panels ) Made Of ( Small Series ) Frame 92 X 44 Mm & Sash 32 X 60 Mm Both Having Wall Thickness Of 1.9 ± 0.2 Mm And Single Glazing Bead Of Appropriate Dimension ( Area Of Window Upto 1.75 Sqm ) . 69 10.16: Steel Work In Built Up Tubular ( Round, Square Or Rectangular Hollow Tubes Etc. ) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete.10.16.1: Hot Finished Welded Type Tubes 70 10.17: Providing And Fixing M.S. Fan Clamp Type I Or Ii Of 16 Mm Dia M.S. Bar, Bent To Shape With Hooked Ends In R.C.C. Slabs Or Beams During Laying, Including Painting The Exposed Portion Of Loop, All As Per Standard Design Complete. 71 10.18: Providing And Fixing Circular / Hexagonal Cast Iron Or M.S. Sheet Box For Ceiling Fan Clamp, Of Internal Dia 140 Mm, 73 Mm Height, Top Lid Of 1.5 Mm Thick M.S. Sheet With Its Top Surface Hacked For Proper Bonding, Top Lid Shall Be Screwed Into The Cast Iron / M.S. Sheet Box By Means Of 3.3 Mm Dia Round Headed Screws, One Lock At The Corners. Clamp Shall Be Made Of 12 Mm Dia M.S. Bar Bent To Shape As Per Standard Drawing. 72 10.28: Providing And Fixing Stainless Steel ( Grade 304 ) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature ( Wherever Required ) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I / C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-Incharge, ( For Payment Purpose Only Weight Of Stainless Steel Membersshall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc. ) . 73 11.2: Brick Soling: Dry Brick On Edge Flooring In Required Pattern With Bricks Of Class Designation 7.5 On A Bed Of 12 Mm Mud Mortar, Including Filling Joints With Jamuna Sand, With Common Burnt Clay Non Modular Bricks. 74 11.5: 62 Mm Thick Cement Concrete Flooring With Concrete Hardener Topping, Under Layer 50 Mm Thick Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ) And Top Layer 12Mm Thick Cement Hardener Consisting Of Mix 1:2 ( 1 Cement Hardener Mix : 2 Graded Stone Aggregate, 6Mm Nominal Size ) By Volume, Hardeningcompound Mixed @ 2 Litre Per 50 Kg Of Cement Or As Per Manufacture’S Specifications. This Includes Cost Of Cement Slurry, But Excluding The Cost Of Nosing Of Steps Etc. Complete. 75 11.41A.3: Glazed Vitrified Tiles Matt / Antiskid Finish Of Size11.41A.3.1: Size Of Tile 600 X 600 Mm 76 Vitrified Floor Tiles:11.47: Providing And Laying Vitrified Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) , With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Brand & Manufacturer, In All Colours And Shade, In Skirting, Riser Of Steps, Laid With Cement Based High Polymer Modified Quick Set Tile Adhesive ( Water Based ) Conforming To Is: 15477, In Average 6 Mm Thickness, Including Grouting Of Joints ( Payment For Grouting Of Joints To Be Made Separately ) .11.47.4: Size Of Tile 1000X1000 Mm 77 11.48: Grouting The Joints Of Flooring Tiles Having Joints Of 3 Mm Width, Using Epoxy Grout Mix Of 0.70 Kg Of Organic Coated Filler Of Desired Shade ( 0.10 Kg Of Hardener And 0.20 Kg Of Resin Per Kg ) , Including Filling / Grouting And Finishing Complete As Per Direction Of Engineer-In-Charge.11.48.4: Size Of Tile 1000X1000 Mm 78 11.55: Providing And Laying Flamed Finish Granite Stone Flooring In Required Designand Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm ( Average ) Thick Base Of Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge :11.55.1: Flamed Finish Granite Stone Slab Jet Black, Cherry Red, Elite Brown, Cat Eye Or Equivalent. 79 12.1: Providing Corrugated G.S. Sheet Roofing Including Vertical / Curved Surface Fixed With Polymer Coated J Or L Hooks, Bolts And Nuts 8 Mm Diameter With Bitumen And G.I. Limpet Washers Or With G.I. Limpet Washers Filled With White Lead, Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete ( Up To Any Pitch In Horizontal / Vertical Or Curved Surfaces ) , Excluding The Cost Of Purlins, Rafters And Trusses And Including Cuttingto Size And Shape Wherever Required.12.1.1: 1.00 Mm Thick With Zinc Coating Not Less Than 275 Gm / M² 80 12.4: Providing Ridges Or Hips Of Width 60 Cm Overall Width Plain G.S. Sheet Fixed With Polymer Coated J Or L Hooks, Bolts And Nuts 8 Mm Dia G.I. Limpet And Bitumen Washers Complete.12.4.1: 0.80 Mm Thick With Zinc Coating Not Less Than 275 Gm / M² 81 12.36: Thermal Insulation Of Roofing With Expanded Polystyrene Fixed With Suitable Adhesive To The False Ceiling As Per The Directions Of The Engineer-In-Charge:12.36.1: With Type N - Normal 50 Mm Thick 82 12.45: Providing And Fixing False Ceiling At All Height Including Providing And Fixing Of Frame Work Made Of Special Sections, Power Pressed From M.S. Sheets And Galvanized With Zinc Coating Of 120 Gms / Sqm ( Both Side Inclusive ) As Per Is : 277 And Consisting Of Angle Cleats Of Size 25 Mm Wide X 1.6 Mm Thick With Flanges Of 27 Mm And 37Mm, At 1200 Mm Centre To Centre, One Flange Fixed To The Ceiling With Dash Fastener 12.5 Mm Dia X 50Mm Long With 6Mm Dia Bolts, Other Flange Of Cleat Fixed To The Angle Hangers Of 25X10x0.50 Mm Of Required Length With Nuts & Bolts Of Required Size And Other End Of Angle Hanger Fixed With Intermediate G.I. Channels 45X15x0.9 Mm Running At The Spacing Of 1200 Mm Centre To Centre, To Which The Ceiling Section 0.5 Mm Thick Bottom Wedge Of 80 Mm With Tapered Flanges Of 26 Mm Each Having Lips Of 10.5 Mm, At 450 Mm Centre To Centre, Shall Be Fixed In A Direction Perpendicular To G.I. Intermediate Channel With Connecting Clips Made Out Of 2.64 Mm Dia X 230 Mm Long G.I. Wire At Every Junction, Including Fixing Perimeter Channels 0.5 Mm Thick 27 Mm High Having Flanges Of 20 Mm And 30 Mm Long, The Perimeter Of Ceiling Fixed To Wall / Partition With The Help Of Rawl Plugs At 450 Mm Centre, With 25Mm Long Dry Wall Screws @ 230 Mm Interval, Including Fixing Of Gypsum Board To Ceiling Section And Perimeter Channel With The Help Of Dry Wall Screws Of Size 3.5 X 25 Mm At 230 Mm C / C, Including Jointing And Finishing To A Flush Finish Of Tapered And Square Edges Of The Board With Recommended Jointing Compound , Jointing Tapes , Finishing With Jointing Compound In 3 Layers Covering Upto 150 Mm On Both Sides Of Joint And Two Coats Of Primer Suitable For Board, All As Per ManufacturerS Specification And Also Including The Cost Of Making Openings For Light Fittings, Grills, Diffusers, Cutouts Made With Frame Of Perimeter Channels Suitably Fixed, All Complete As Per Drawings, Specification And Direction Of The Engineer In Charge But Excluding The Cost Of Painting With :12.45.4 Fully Perforated Gypsum Plaster Board Of Size 1200 X 2400X12.5 Mm Having Approx. 15 % Perforated Area With Perforation Size And Pattern As Approved By The Engineerin-Charge And As Per ManufacturerS Specification, With All 4 Side Tapered And Backed By Acoustical Tissue With Nrc Value Not Less Than 0.60 83 12.52: Providing And Fixing Tiled False Ceiling Of Specified Materials Of Size 595X595 Mm In True Horizontal Level, Suspended On Inter Locking Metal Grid Of Hot Dipped Galvanized Steel Sections ( Galvanized @ 120 Grams / Sqm, Both Side Inclusive ) Consisting Of Main T Runner With Suitably Spaced Joints To Get Required Length And Of Size 24X38 Mm Made From 0.30 Mm Thick ( Minimum ) Sheet, Spaced At 1200 Mm Center To Center And Cross T Of Size 24X25 Mm Made Of 0.30 Mm Thick ( Minimum ) Sheet, 1200 Mm Long Spaced Between Main T At 600 Mm Center To Center To Form A Grid Of 1200X600 Mm And Secondary Cross T Of Length 600 Mm And Size 24X25 Mm Made Of 0.30 Mm Thick ( Minimum ) Sheet To Be Interlocked At Middle Of The 1200X600 Mm Panel To Form Grids Of 600X600 Mm And Wall Angle Of Size 24X24x0.3 Mm And Laying False Ceiling Tiles Of Approved Texture In The Grid Including, Required Cutting / Making, Opening For Services Like Diffusers, Grills, Light Fittings, Fixtures, Smoke Detectors Etc. Main T Runners To Be Suspended From Ceiling Using Gi Slotted Cleats Of Size 27 X 37 X 25 X1.6 Mm Fixed To Ceiling With 12.5 Mm Dia And 50 Mm Long Dash Fasteners, 4 Mm Gi Adjustable Rods With Galvanised Butterfly Level Clips Of Size 85 X 30 X 0.8 Mm Spaced At 1200 Mm Center To Center Along Main T, Bottom Exposed Width Of 24 Mm Of All T-Sections Shall Be Pre-Painted With Polyester Paint, All Complete For All Heights As Per Specifications, Drawings And As Directed By Engineer-In-Charge.12.52.2: Gi Metal Ceiling Lay In Perforated Tegular Edge Global White Color Tiles Of Size 595X595 Mm And 0.5 Mm Thick With 8 Mm Drop; Made Of Gi Sheet Having Galvanizing Of 100 Gms / Sqm ( Both Sides Inclusive ) And 20% Perforation Area With 1.8 Mm Dia Holes And Having Nrc ( Noise Reduction Coefficient ) Of 0.5, Electro Statically Polyester Powder Coated Of Thickness 60 Microns ( Minimum ) , Including Factory Painted After Bending And Perforation, And Backed With A Black Glass Fiber Acoustical Fleece. 84 12.55: Providing And Fixing Heat Resistant Terrace Tiles ( 300 Mm X 300 Mm X 20 Mm ) With Sri ( Solar Refractive Index ) > 78, Solar Reflection > 0.70 And Initial Emittance > 0.75 On Waterproof And Sloped Surface Of Terrace, Laid On 20 Mm Thick Cement Sand Mortar In The Ratio Of 1:4 ( 1 Cement : 4 Coarse Sand ) And Grouting The Joints With Mix Of White Cement & Marble Powder In Ratio Of 1:1, Including Rubbing And Polishing Of The Surface Upto 3 Cuts Complete, Including Providing Skirting Upto 150 Mm Height Along The Parapet Walls In The Same Manner. 85 13.1: 12 Mm Cement Plaster Of Mix :13.1.1: 1:4 ( 1 Cement: 4 Fine Sand ) 86 13.2: 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix :13.2.1: 1:4 ( 1 Cement: 4 Fine Sand ) 87 13.3: 20 Mm Cement Plaster Of Mix :13.3.1: 1:4 ( 1 Cement: 4 Fine Sand ) 88 13.7: Cement Plaster With A Floating Coat Of Neat Cement 12 Mm Cement Plaster Finished With A Floating Coat Of Neat Cement Of Mix : 13.7.2: 1:4 ( 1 Cement: 4 Fine Sand ) 89 Exterior Finishing13.44: Finishing Walls With Water Proofing Cement Paint Of Required Shade :13.44.1 New Work ( Two Or More Coats Applied @ 3.84 Kg / 10 Sqm ) 90 13.45: Finishing Walls With Textured Exterior Paint Of Required Shade :13.45.1: New Work ( Two Or More Coats Applied @ 3.28 Ltr / 10 Sqm ) Over And Including Priming Coat Of Exterior Primer Applied @ 2.20Kg / 10 Sqm 91 Exterior Finishing13.47: Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade:13.47.1 New Work ( Two Or More Coats Applied @ 1.43 Ltr / 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg / 10 Sqm ) 92 13.80: Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. 93 13.82: Wall Painting With Acrylic Emulsion Paint, Having Voc ( Volatile Organic Compound ) Content Less Than 50 Grams / Litre, Of Approved Brand And Manufacture, Including Applying Additional Coats Wherever Required, To Achieve Even Shade And Colour.13.82.2: Two Coats 94 13.85: Applying Priming Coats With Primer Of Approved Brand And Manufacture, Having Low Voc ( Volatile Organic Compound ) Content.13.85.3: With Water Thinnable Cement Primer On Wall Surfacehaving Voc Content Less Than 50 Grams / Litre 95 16.12: Dry Brick Pitching Half Brick Thick In Drains Including Supply Of Bricks And Preparing The Surface Complete :16.12.1 With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 96 16.91: Providing And Laying Factory Made Chamfered Edge Cement Concrete Paver Blocks In Footpath, Parks, Lawns, Drive Ways Or Light Traffic Parking Etc, Of Required Strength, Thickness & Size / Shape, Made By Table Vibratory Method Using Pu Mould, Laid In Required Colour & Pattern Over 50Mm Thick Compacted Bed Of Sand, Compacting And Proper Embedding / Laying Of Inter Locking Paver Blocks Into The Sand Bedding Layer Through Vibratory Compaction By Using Plate Vibrator, Filling The Joints With Sand And Cutting Of Paver Blocks As Per Required Size And Pattern, Finishing And Sweeping Extra Sand. Complete All As Per Direction Of Engineer-In-Charge.16.91.2: 80 Mm Thick C.C. Paver Block Of M-30 Grade With Approved Color Design And Pattern. 97 20.1: Providing, Driving With Hydraulic Piling Rigs With Power Units And Installing Driven Cast-In-Situ Reinforced Cement Concrete Piles Of Grade M-25 Of Specified Diameter And Length Below The Pile Cap, To Carry Safe Working Load Not Less Than Specified, Excluding The Cost Of Steel Reinforcement But Including The Cost Of Shoe And The Length Of Pile To Be Embedded In The Pile Cap Etc. All Complete. ( Length Of Pile For Payment Shall Be Measured From Top Of Shoe To The Bottom Of Pile Cap ) :20.1.3: 500 Mm Dia Piles 98 22.3: ( Ii ) Providing And Laying Water Proofing Treatment To Vertical And Horizontal Surfaces Of Depressed Portions Of W.C., Kitchen And The Like Consisting Of: ( I ) Ist Course Of Applying Cement Slurry @ 4.4 Kg / Sqm Mixed With Water Proofing Compound Conforming To Is 2645 In Recommended Proportions Including Rounding Off Junction Of Vertical And Horizontal Surface. ( Ii ) Iind Course Of 20 Mm Cement Plaster 1:3 ( 1 Cement : 3 Coarse Sand ) Mixed With Water Proofing Compound In Recommended Proportion Including Rounding Off Junction Of Vertical And Horizontal Surface. ( Iii ) Iiird Course Of Applying Blown Or Residual Bitumen Applied Hot At 1.7 Kg. Per Sqm Of Area. ( Iv ) Ivth Course Of 400 Micron Thick Pvc Sheet. ( Overlaps At Joints Of Pvc Sheet Should Be 100 Mm Wide And Pasted To Each Other With Bitumen @ 1.7 Kg / Sqm ) . 99 22.5: Providing And Laying Water Proofing Treatment In Sunken Portion Of Wcs, Bathroom Etc., By Applying Cement Slurry Mixed With Water Proofing Cement Compound Consisting Of Applying : ( A ) First Layer Of Slurry Of Cement @ 0.488 Kg / Sqm Mixed With Water Proofing Cement Compound @ 0.253 Kg / Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours. ( B ) Second Layer Of Slurry Of Cement @ 0.242 Kg / Sqm Mixed With Water Proofing Cement Compound @ 0.126 Kg / Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours Followed With Water Curing For 48 Hours.The Rate Includes Preparation Of Surface, Treatment And Sealing Of All Joints, Corners, Junctions Of Pipes And Masonry With Polymer Mixed Slurry. 100 25.8: Design Supply & Installation Of Suspended Spider Glazing Systemdesigned To Withstand The Wind Pressure As Per Is 875 ( Part-Iii ) . The Suspended System Held With Spider Fittings Of Ss-316 Grade Steel Of Approved Manufacturer With Glass Panel Having 12 Mm Thick Clear Toughened Glass Held Together With Ss- 316 Grade Stainless Steel Spider & Bolt Assembly With Laminated Glass Fins 21 Mm Thick. The Glass Fins And Glass Panel Assembly Shall Be Connected To Slab / Beams By Means Of Ss- 316 Grade Stainless Steel Brackets & Anchor Bolts And At The Bottom Using Ss Channel Of 50X25x2mm Using Fastener & Anchor Bolts, Non Staining Weather Sealants Of Approved Make, Teflon / Nylon Bushes And Separators To Prevent Bi-Metallic Contacts, All Complete To Perform As Per Specification And Approved Drawings. The Complete System To Be Designed To Accommodate Thermal Expansion & Seismic Movements Etc. The Joints Betweenglass Panels ( 6 To 8 Mm ) And Gaps At The Perimeter & In U Channel Of The Assembly To Be Filled With Non Staining Weather Sealant, So As To Make The Entire System Fully Water Proof & Dust Proof. 101 26.1: Providing & Fixing In Position Phenol Bonded Bamboowood Flooring With Planks Of Sizes 14Mm Thick, Minimum 1800Mm Length And Minimum 100 Mm Wide, In Approved Colour, Texture And Finish, Having Performance Appraisal Certificate ( Pac ) Issued By Building Materials & Technology Promotion Council ( Bmtpc ) . The Flooring Shall Be Fixed With Tongue And Groove Interlocking System, With Underlayment Of 4Mm Thick Expanded Polyethylene Foam Sheets Having Density 40Kg / Cum, Over Prepared Surface With Necessary Quarter Round Planks Of Size 1900Mm X 18Mm And Door Reducer Of Size 1900Mm X 44Mm, Wherever Required. The Bamboowood Planks Shall Have Minimum Density Of 1000 Kg / Cum & Minimum Hardness 1000 Kgf. With Eco Friendly Uv Coating, All Complete As Per Direction Of The Engineer In-Charge. 102 26.3: Providing & Fixing In Position Phenol Bonded Bamboowood Wall Cladding At All Height With Planks Of Sizes 10Mm Thick, Minimum 1800Mm Length And Minimum 100 Mm Wide, In Approved Colour, Texture And Finish, Having Performance Appraisal Certificate ( Pac ) Issued By Building Materials & Technology Promotion Council ( Bmtpc ) , With Necesasary Profiled Edges Fixed With 40Mm Ss Screws 5 Nos In Each Tile To Frame Work Made Of Second Class Teak Wood Of Size 20X15 Mm In Centre Of Each Tile And Bottom And Top Of Work Height, 40X15mm Placed At Ends Of Each Tile. The Cladding Shall Be Laid Over Backlayment Of 1.00 Mm Thick Expanded Polyethylene Foam Of Density 40Kg / Cum In Two Layers, First Layer On Wall Surface Before Fixing Wooden Frame And Second Layer On Frame Under Cladding. The Bamboowood Planks Shall Have Minimum Density Of 1000 Kg / Cum & Minimum Hardness 1000 Kgf. With Eco Friendly Uv Coating, All Complete As Per Direction Of The Engineer In-Charge. 103 Providing & Installation Of 16 Passenger Lift With Speed 1.5M / Sec 104 Sanitary Works:17.7: Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require:17.7.1:White Vitreous China Wash Basin Size 630X450 Mm With A Pair Of 15 Mm C.P. Brass Pillar Taps 105 17.10: Providing And Fixing Stainless Steel A Isi 304 ( 18 / 8 ) Kitchen Sink As Per Is:13983 With C.I. Brackets And Stainless Steel Plug 40 Mm, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Required 17.10.1:Kitchen Sink With Drain Board17.10.1.2: 510X1040 Mm Bowl Depth 225 Mm 106 17.32: Providing And Fixing Mirror Of Superior Glass ( Of Approved Quality ) And Of Required Shape And Size With Plastic Moulded Frame Of Approved Make And Shade With 6 Mm Thick Hard Board Backing :17.32.2: Rectangular Shape 453X357 Mm 107 17.68: Providing And Fixing Vitreous China Dual Purpose Closet Suitable For Use As Squatting Pan Or European Type Water Closet ( Anglo Indian W.C Pan ) With Seat & Lid Fixed With C.P. Brass Hinges And Rubber Buffers, 10 Litre Low Level Flushing Cistern With Fitting And Brackets, 40Mm Flush Bend, 20 Mm Over Flow Pipe, With Specials Of Standard Make And Mosquito Proof Coupling Of Approved Municipal Design Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required:17.68.1: White Vitreous China Dual Purpose Wc Pan With Whitesolid Plastic Seat And Lid With White Vitreous China Flushingcistern And C.P. Flush Bend. 108 17.72: Providing And Fixing Ptmt Towel Ring Trapezoidal Shape 215 Mm Long, 200 Mm Wide With Minimum Distances Of 37 Mm From Wall Face With Concealed Fittings Arrangement Of Approved Quality And Colour, Weighing Not Less Than 88 Gms. 109 18.7: Providing And Fixing Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge.Internal Work - Exposed On Wall18.7.4: 32 Mm Nominal Dia Pipes 110 18.7.5: 40 Mm Nominal Dia Pipes 111 18.8: Providing And Fixing Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, I / C Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer In Charge.Concealed Work, Including Cutting Chases And Making Good The Walls Etc.18.8.3: 25 Mm Nominal Dia Pipes 112 18.34: Constructing Masonry Chamber 90X90x100 Cm Inside, In Brick Work In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) For Sluice Valve, With C.I. Surface Box 100 Mm Top Diameter, 160 Mm Bottom Diameter And 180 Mm Deep ( Inside ) With Chained Lid And Rcc Top Slab 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , I / C Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40 Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) 12 Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design : 113 18.48: Providing And Placing On Terrace ( At All Floor Levels ) Polyethylene Water Storage Tank, Is : 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank. 114 18.50: Providing And Fixing C.P. Brass Long Nose Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 810 Gms.18.50.1: 15 Mm Nominal Bore 115 18.58: Providing And Fixing Ptmt Grating Of Approved Quality And Colour.18.58.1: Circular Type18.58.1.2: 125 Mm Nominal Dia With 25 Mm Waste Hole 116 19.32: Making Soak Pit 2.5 M Diameter 3.0 Metre Deep With 45 X 45 Cm Dry Brick Honey Comb Shaft With Bricks And S.W. Drain Pipe 100 Mm Diameter, 1.8 M Long Complete As Per Standard Design.19.32.1: With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 117 Providing, Fitting And Fixing 100 Mm Nominal Dia Pipes 118 Providing And Fixing Victorian Shower Headalong With Wall Mixer 119 Providing And Fixing Table Top Basin ( Acs-Wht-87901; Size-575 X 430 X 175 Mm ) 120 Providing And Fixing Basin Mixer Without Popup Waste System15mm Cartridge Size; Model- Arc-87189 121 Providing And Fixingwaste Coupling ; Model- Ald-Chr-727L130; Full Thread With 13Mm Height 122 Providing And Fixing Swivel Mirror ( 630 X 445Mm ) ; Model- Akp-Chr-35795 123 Providing And Fixing Towel Holder; Model- Qua-Chr-61723 124 Providing And Fixing Wall Hung Water Close With Uf Soft Close Seat Cover Hinges Set Size- 360 X 585 X 415Mm; Model - Ops-Wht-15951Uf 125 Providing And Fixing Pneumatic Single Piece Slim Concealed Cistern With Floor Mounting Fram Installation Kid And P Type Drain Pipe Connection Set For Wall 126 Providing And Fixing Two Way Bib Cock With Wall Flange; Model- Orp-10041Pm 127 Providing And Fixing Pillar Cock Auto Closing; Model- Prs-Chr-031 128 Providing And Fixing Exposed Part Kit Of Single Lever Basin Mixer Wall Mounted Consisting Of Operating Lever Cartridge Sleeve Wall Flange Nipple & Spout ( Compatible With Ald-233N & Ald-235N; Model- Ali- Chr-85233Nk 129 Providing And Fixing Angular Stop Cock With Wall Flangre; Model- Leb-Chr-45053 130 Providing And Fixing Sink Cock With Regular Swinging Spout ( Wall Mounted Model ) With Wall Flange ; Model:- Qqp-7347Pm 131 Providing And Fixing Toilet Roll Holder With Flap ; Model- Qua-Chr-61753 132 Providing And Fixing Bottle Trap ; Model-Ald-Chr-769L300x190; 32Mm Size With 300Mm & 190Mm Long Wall Connection Pipes & Wall Flange 133 Providing And Fixing Health Faucet ; 8Mm Dia 1.2 M Long Flexble Tube And Wall Hook; Model No- Ald-Chr-573 134 Providing And Fixing Cilica Pneumatic White Glass Control Plate; Model-Acp-Chr-573 135 Providing And Fixing Hand Shower 75Mm Dia Cylindrical Shape ( Rain Massage & Mist ) Chrome Plated Abs Body With Gray Face Plate & Rubit Cleaning System; Model- Hsh-Chr-1797 136 Providing And Fixing Victorian Shower Head Round Black Chrome ; Model-Ohs-Bch-1843; 137 Providing And Fixing Shower Arm Dia. 20Mm & 300Mm Long Round Shape With 90° Bend For Wall Mounted Showers With Flange Stainless Steel ; Model- Sha-Bch-479L300s 138 Providing And Fixing Concealed Body Foy Joystick Diverter 40Mm Catridge With Button Assembly Model No:- Arc-87065C 139 Providing And Fixing Exposed Part Kit Of Joystick Basin Mixer Wall Mounted Consisting Of Operating Lever, Cartridge Sleeve, Wall Flange, Nipple & Spout ; Model No:- Arc-87233K 140 Providing And Fixing Signac Spout For Built In Bath / Showe Mixer; Model- Spt-Chr-41429 141 Providing And Fixing Towel Reck With Lower Hanger With Hook; Model- Ahs-1581H 142 Providing And Fixing Optima Sliding Dr 8Mm Rt. ( 1000-1500Mm ) X 2000M; Model- Jse-Chr-Optsdr1015x 143 Providing And Fixing Wc Brush Holder; Model- Qua-Chr-61743 144 Providing And Fixing Stainless Steel Shelfe; Model- Qua-Chr-61775 145 Providing And Fixing Double Coat Hook; Model- Qua-Chr-61761 146 Internal Electrical Work Em ( 20 Units ) :1.10.3: Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. 147 1.12: Wiring For Light / Power Plug With 2X4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit Alongwith 1 No. 4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. 148 1.13: Wiring For Light / Power Plug With 4X4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit Alongwith 2 Nos. 4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. 149 1.14: Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required.1.14.1: 2 X 1.5 Sq. Mm + 1 X 1.5 Sq. Mm Earth Wire 150 1.14.2: 2 X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire 151 1.14.9: 4 X 6 Sq. Mm + 2 X 6 Sq. Mm Earth Wire 152 1.14.10: 4 X 10 Sq. Mm + 2 X 6 Sq. Mm Earth Wire 153 1.31: Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 3 Pin 5 / 6 A Modular Socket Outlet And 5 / 6 A Modular Switch, Connections Etc. As Required. 154 1.32: Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 6 Pin 5 / 6 & 15 / 16 A Modular Socket Outlet And 15 / 16 A Modular Switch, Connections Etc. As Required. 155 1.56: Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providng And Fixing 2 Nos. 3 Pin 5 / 6 A Modular Socket Outlet And 2 Nos. 5 / 6 A Modular Switch, Connections Etc. As Required. ( For Light Plugs To Be Used In Non Residential Buildings ) . 156 Mr: Supply, Fixing, Wiring, Testing & Commissioning For Single Phase20 / 25 Amppower Plug Outlets In Seperate Recessed Zinc Chromate Passivated Ms Box With 4 Sq.Mm. Frinsulated Copper Conductor Wires Alongwith 2.5 Sq.Mm. Fr Insulated Copper Conductor Wire For Loop Earthingin Concealed 2Mm Thickpvc Conduits ( Isi Marked ) As Calledfor Includingproviding 6 Pin Modular Socketoutlet With Box, Ferrule Numbering, Etc. Complete As Required For Geyser. 157 1.57: Supplying & Fixing Suitable Size Gi Box Wih Modular Plate And Cover In Front On Surface Or In Recess Including Providing And Fixing 25 A Modular Socket Outlet And 25 A Modular Sp Mcb, C Curve Including Connections, Painting Etc. As Required. ( Ac ) 158 2.18: Supplying And Fixing 20 A, 240 V, Spn Industrial Type Socket Outlet, With 2 Pole And Earth, Metal Enclosed Plug Top Alongwith 20 A C Curve, Sp, Mcb, In Sheet Steel Enclosure, On Surface Or In Recess, With Chained Metal Cover For The Socket Out Let And Complete With Connections, Testing And Commissioning Etc. As Required. 159 1.21: Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. 160 1.21.1: 20 Mm 161 1.21.2: 25 Mm 162 1.21.3: 32Mm 163 1.21.4: 40Mm 164 1.26: Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate & Switch Box Excluding Modular Plate As Required. 165 1.21: Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.1.21.1: 20 Mm 166 1.21.2: 25 Mm 167 1.20: Supplying And Fixing Of Following Sizes Of Steel Conduit Along With Accessories In Surface / Recess Including Painting In Case Of Surface Conduit, Or Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.1.20.2: 25 Mm 168 2.3: Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 2.3.2: 6 Way, Double Door 169 2.3.3: 12 Way, Double Door 170 2.4: Supplying And Fixing Following Way, Horizontal Type Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 2.4.1: 4 Way ( 4+12 ) , Double Door 171 2.4.2: 6 Way ( 4+18 ) , Double Door 172 2.4.3: 8 Way ( 4+24 ) , Double Door 173 2.5: Supplying And Fixing Of Following Ways Surface / Recess Mounting, Vertical Type, 415 V, Tpn Mcb Distribution Board Of Sheet Steel, Dust Protected, Duly Powder Painted, Inclusive Of 200 A Tinned Copper Bus Bar, Common Neutral Link, Earth Bar, Din Bar For Mounting Mcbs ( But Without Mcbs And Incomer ) As Required . ( Note : Vertical Type Mcb Tpdb Is Normally Used Where 3 Phase Outlets Are Required. ) 2.5.3: 12 Way ( 4 + 36 ) , Double Door 174 2.10: Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.2.10.1: Single Pole 175 2.12: Supplying And Fixing Following Rating, Double Pole, 240 V, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.2.12.1: 40 Amps 176 2.12.2: 63 Amps 177 2.13: Supplying And Fixing Following Rating, Four Pole, 415 V, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.2.13.1: 40 Amps 178 2.13.2: 63 Amps 179 2.14: Supplying And Fixing Following Rating, Double Pole, ( Single Phase And Neutral ) , 240 V, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.2.14.2: 40 Amps ( 30Ma ) 180 2.14.3: 63 Amps ( 30Ma ) 181 2.11: Supplying And Fixing Single Pole Blanking Plate In The Existing Mcb Db Complete Etc. As Required. 182 A. Supply Of Lighting Fixturte:Supplying With Fitting Fixing Ofluminaries Complete With All Accessories Such As Ballast, Starter Etc. Directly On Wall / Ceiling Including Connection As Approved By The Deptt. ) With 1.5 Sq Mm P.V.C. Insulated S.C. Copper Conductor As Required And As Directed By The Department. Mr:Flourescent Tube Light ( Tl ) 183 Mr: Mirror Light 184 Mr: Decorative Bracket ( Bkd ) 185 Mr: 18W Ceiling / Surface Mounted Ledfixture 186 Mr: 1X18w Led Light In Staircase Area 187 Mr: Ceiling Fan 188 Mr: Exhaust Fan : 450 Mm Sweep Metal Body Copper Motor 189 Mr: Supply Of 10W Bulkhead ( Panasonic Make ) Model- Panasonic Pbhm01107 With Or Equivalent ( Equivalent Will Be Selected By The Deptt Considering The Mother Items Rate ) Make. 190 Mr: Supply Of 20 Wattled Tube ( Panasonic Make ) Model- Panasonic Pbtm02207bs With Or Equivalent ( Equivalent Will Be Selected By The Deptt Considering The Mother Items Rate ) Make. 191 Mr: Supply Of12 Watt Surface Mounted Ceiling Light ( Panasonic Make ) Model- Panasonic Ppam16127 Or Equivalent ( Equivalent Will Be Selected By The Deptt Considering The Mother Items Rate ) Make. 192 Mr: Supply Of18 Wattsurface Mounted Ceiling Light ( Panasonic Make ) Model- Panasonicppam16187 Or Equivalent ( Equivalent Will Be Selected By The Deptt Considering The Mother Items Rate ) Philips / Make. 193 B. Installation Of Lighting Fixtures:1.41: Installation, Testing And Commissioning Of Following Pre-Wired, Led Fitting Of All Types, Complete With All Accessories And Tube Etc. Directly On Ceiling / Wall, Including Connection With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable And Earthing Etc. As Required. 194 1.44: Installation, Testing And Commissioning Of Ceiling Fan, Including Wiring The Down Rods Of Standard Length ( Upto 30 Cm ) With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable Etc. As Required. 195 1.45: Installation, Testing And Commissioning Of Ceiling Fan, Wiring The Down Rods Of Standard Length ( Upto 30 Cm ) With 1.5 Sq. Including Mm Fr Pvc Insulated, Copper Conductor, Single Core Cable, Including Providing And Fixing Phenolic Laminated Sheet Cover On The Fan Box Etc. As Required. 196 1.35: Installation , Testing, Commissioning Of Wall Bracket / Ceiling Fittings Of All Sizes And Shapes Containing Upto Two Gls / Cfl / Led Lamps Per Fitting, Complete With All Accessories Including Connections Etc. As Required. 197 1.41: Installation, Testing And Commissioning Of Pre-Wired, Fluorescent Fitting / Compact Fluorescent Fitting Of All Types, With All Accessories And Tube Etc. Directly On Ceiling / Wall, Including Connection With 1.5 Sq. Mm Fr Pvc Insulated, Copper Conductor, Single Core Cable And Earthing Etc. As Required. 198 1.34: Supplying And Fixing Brass Batten / Angle Holder Including Connection Etc. As Required. 199 1.25: Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 200 1.50: Installation Of Exhaust Fan In The Existing Opening, Including Making Good The Damage, Connection, Testing, Commissioning Etc. As Required.1.50.1: Upto 450 Mm Sweep 201 Cable Trays / Raceways:4.6: Supplying And Installing Following Size Of Perforated Hot Dipped, Galvanised Iron Cable Tray ( Galvanisation Thickness Not Less Than 50 Microns ) With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling / Shaft With G.I. Suspenders Including G.I. Bolts & Nuts, Etc. As Required& Approved By The Engineer Incharge. ( Quantity Shall Be Confirmed At Site As Per Final Layout / Route / Application Etc. & To Be Executed Accordingly. ) 4.6.6: 450 Mm Width X 50 Mm Depth X 1.6 Mm Thickness 202 4.6.4: 300 Mm Width X 50 Mm Depth X 1.6 Mm Thickness 203 4.6.2: 150 Mm Width X 50 Mm Depth X 1.6 Mm Thickness 204 Earthing:5.4: Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal / Coke And Salt As Required. 205 5.5: Earthing With Copper Earth Plate 600 Mm X 600 Mm X 3 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. ( But With Charcoal / Coke And Salt ) As Required. 206 5.9: Supplying And Laying 25 Mm X 5 Mm G.I Strip At 0.50 Metre Below Ground As Strip Earth Electrode, Including Connection / Terminating With G.I. Nut, Bolt, Spring, Washer Etc. As Required. ( Jointing Shall Be Done By Overlapping And With 2 Sets Of G.I. Nut Bolt & Spring Washer Spaced At 50Mm ) 207 5.11: Providing And Fixing 25 Mm X 5 Mm G.I. Strip In 40 Mm Dia G.I. Pipe From Earth Electrode Including Connection With G.I. Nut, Bolt, Spring, Washer Excavation And Re-Filling Etc. As Required. 208 5.15: Providing And Fixing 25 Mm X 5 Mm G.I. Strip On Surface Or In Recess For Connections Etc. As Required. 209 5.19: Providing And Fixing 4.00 Mm Dia Copper Wire On Surface Or In Recess For Loop Earthing Along With Existing Surface / Recessed Conduit / Submain Wiring / Cable As Required 210 5.18: Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing Along With Existing Surface / Recessed Conduit / Submain Wiring / Cable As Required. 211 5.14: Providing And Fixing 25 Mm X 5 Mm Copper Strip In 40 Mm Dia G.I. Pipe From Earth Electrode Including Connection With Brass Nut, Bolt, Spring, Washer Excavation And Re-Filling Etc. As Required. 212 Cable Laying, Terminations And Glands:7.7: Laying And Fixing Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size On Wall Surface As Required.7.7.1: Upto 35 Sq. Mm 213 7.7.2: Above 35 Sq. Mm And Upto 95 Sq. Mm ( Clamped With 25X3mmms Flat Clamp ) 214 7.7.4: Above 185 Sq. Mm And Upto 400 Sq. Mm ( Clamped With40x3mm Ms Flat Clamp ) 215 9.1: Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required.9.1.32: 4 Core X 10.0 Sq. Mm. Xlpe, Al.Armoured Cable. 216 9.1.33: 4 Core X 16.0 Sq. Mm. Xlpe, Al.Armoured Cable. 217 9.1.22: 3.5 Core X 50.0 Sq. Mm. Xlpe, Al.Armoured Cable. 218 9.1.30: 3.5 Core X 300 Sq. Mm. Xlpe, Al.Armoured Cable. 219 Cable Tray :4.1: Supplying And Installing Following Size Of Perforated Painted With Powder Coating M.S. Cable Trays With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With M.S. Suspenders Including Bolts & Nuts, Painting Suspenders Etc As Required.4.1.1: 100 Mm Width X 50 Mm Depth X 1.6 Mm Thickness 220 4.1.2: 150 Mm Width X 50 Mm Depth X 1.6 Mm Thickness 221 4.1.6: 450 Mm Width X 50 Mm Depth X 1.6 Mm Thickness 222 4.1.7: 600 Mm Width X 50 Mm Depth X 1.6 Mm Thickness 223 4.2: Supplying And Installing Following Size Of Perforated Painted With Powder Coating M.S. Cable Trays Bends With Perforation Not More Than 17.5%, , Joined With Connectors, Suspended From The Ceiling With M.S. Suspenders Including Bolts & Nuts, Paintingsuspenders Etc As Required.4.2.1: 100 Mm Width X 50 Mm Depth X 1.6 Mm Thickness 224 4.2.2: 150 Mm Width X 50 Mm Depth X 1.6 Mm Thickness 225 4.2.6: 450 Mm Width X 50 Mm Depth X 1.6 Mm Thickness 226 4.2.7: 600 Mm Width X 50 Mm Depth X 1.6 Mm Thickness 227 Data And Tv Points:1.53: Supplying And Drawing Of Utp 4 Pair Cat 6 Lan Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required.1.53.1: 1 Run Of Cable 228 1.18: Supplying And Drawing Following Pair 0.5 Mm Dia Frls Pvc Insulated Annealed Copper Conductor, Unarmored Telephone Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required.1.18.2: 2 Pair 229 1.19: Supplying And Drawing Co-Axial Tv Cable Rg-6 Grade, 0.7 Mm Solid Copper Conductor Pe Insulated, Shielded With Fine Tinned Copper Braid And Protected With Pvc Sheath In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 230 Mr: Supplying And Drawing Co-Axial Tv Cable Rg-11 Grade, 0.7 Mm Solid Copper Conductor Pe Insulated, Shielded With Fine Tinned Copper Braid And Protected With Pvc Sheath In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 231 1.24: Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.1.24.7: Tv Antenna Socket Outlet 232 1.24.6: Telephone Socket Outlet 233 1.38: Supplying And Fixing Call Bell / Buzzer Suitable For Single Phase, 230 V, Complete As Required. 234 1.27: Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required.1.27.1: 1 Or 2 Module ( 75Mmx75mm ) 235 1.27.2: 3 Module ( 100Mmx75mm ) 236 1.27.4: 6 Module ( 200Mmx75mm ) 237 1.27.5: 8 Module ( 125Mmx125mm ) 238 Mr: Supply, Erection, Testing And Commissioning Of Following Tap Off / Splitter As Per Specification In 1.6Mm Thick Crca Sheetsteel Enclosurefor Catvsystem.Mr: 4 Way Splitter Box 239 1.21: Supplying And Fixing Of Following Sizes Of Heavy Duty Class Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.1.21.1: 20 Mm 240 1.21.2: 25 Mm 241 Electrical External Works ( Em 20 Units ) :7.7: Laying And Fixing Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size On Wall Surface As Required.7.7.1: Upto 35 Sq. Mm 242 9.1: Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required.4 Core X 10.0 Sq. Mm. Xlpe, Al.Armoured Cable. 243 4 Core X 16.0 Sq. Mm. Xlpe, Al.Armoured Cable. 244 Earthing:5.18: Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Earthing Along With Existing Surface / Recessed Conduit As Required. ( Pole Earthing ) 245 Feeder Pillar:Nsr: Design, Fabrication, Assembling, Wiring, Testing, Supply, Forwarding To Site, Unloading, Shifting To Location, Inspection, Installation, Testing And Commissioning Of M.V.Feeder Pillar Outdoor Typeboards Suitable For 415V, 3 Phase, 4 Wire, 50Hz Distribution System. The Panel Shall Be Fabricated Out Of 2 Mm Crca Sheet Steel In Cubicle Formation, Compartmentalized, Form 3B Construction, Free Standing, Floor Mounting, Dust And Vermin Proofwithreinforcementofsuitablesizeangleiron, Channel, T Sections And / Or Flats Wherever Necessary. The Panel Shall Be Treated Withanticorrosiveprocessbeforefinalpowdercoating.Separate Earth Busshall Be Provided Throughout The Length Of The Panel. The Incoming And The Outgoing Feeder Breakers, Switch Fuse Units, Change Over Switches, Indicating Lamps, Meters Etc. Shall Be Accommodated In A Modular Multi Tier Arrangement. A Minimum Of 400Mm Clearance Shallbegivenfromthefloorleveltothebottommosttermination Point. The Painting Shall Be Done In Conformity With Is Code.Adequate Size Cable Alley Shall Be Provided All Round The Panel And At The Back For Easy Bending And Terminations. The Outgoing Feeders Inside The Panel Shall Be Connected Through Solid Busbars. Flexible Cable Links Are Not Acceptable. Bus Bars Shall Be Provided With Pvc Heat Shrinkable Sleeves Or Heat Resistant Insulated Paint. The Panels Shall Be Suitable For Cable Entry From Top / Bottom. The Copper Earth Strip Of Adequate Size In 2 Runs Shall Run Through Out The Perimeter Of The Bottom Of The Panel. The Panel Shall Be Fabricated Only After The Approval Of Fabrication Drawings By The Consultant.100 Amp Al Bus Bar63 Amp Fp Mccb 10Ka-1 Nos 16 Amp Tpn Mcb 10Ka-8 Nossuitable Timer And Contactor Arrangement To Be Maid Offpanel As Above 246 Cable Supply :Supplying Offollowing 1100 Voltgradexlpe Insulated Pvc Inner Sheathed And Frls Pvc Outer Sheathed Copper / Aluminiumconductor Armoured Cables As Per Specification.Nsr: 4 Core X 10.0 Sq. Mm. Xlpe, Cu. Armoured Cable. 247 Nsr: 4 Core X 16.0 Sq. Mm. Xlpe, Cu. Armoured Cable. 248 Earthing:Supply And Fixing 1 Meter Long Gi Spike For Pole Earthing . 249 Lighting Fixture:Nsr: Supplying Installation Testing & Commissioning Of 25W Led Street Light Fixture With System Efficacy Of 100 Lm / W ( 2500 Lumens ) . Luminaire Shall Be Made Up Of Die Cast Aluminium Housing With Pc Lens And Ploycarbonate Diffuser. Luminaire Shall Be Designed With Street Optic Lens For Uniform Light Distribution. Lm 80-08 Compliant Leds From Reputed Makes Should Be Provided. Leds Used In The Product Shall Comply With En 62471 For Photo-Biological Safety And Certificate For The Same From Manufacturer Shall Be Provided. Luminaire Shall Be With Ip66 Protection. The Led Shall Be Compliant With Lm80-08 Standard With L70 Life Of 50000 Hrs Tested At Maximum Current ( Complete Lm 80 Test Report For Led Should Be Submitted For 10000 Hrs Of Testing ) . The Leds Used Should Be With Cct Of 5700 K And Cri Of Minimum 70. Led Driver Shall Be Potted, Integrated Type, Multistage, Isolated, Apfc Constant Current-Constant Voltage Operated Driver With Range 150-270V Ac And Safety Extra Low Voltage < 60V Dc As Per Iec Standard., Driver Efficiency > 85% & 4 Kv Internal Surge Protection, Power Factor Greater Than 0.95 And Total Harmonic Distortion ( Thd ) Of Less Than 10% Should Be Integral To The Luminaire. Compliance To Indian Standards Of Is10322 Part 5 / Sect 1:1967; 16105 : 2012; Is 16106 : 2012; Is 15885 ( Part2 / Sec13 ) : 2012; Is 16108 : 2012. 250 Nsr: Supplying Installation Testing & Commissioning Of 150W Led Floodlight Fixture With System Efficacy Of 100 Lm / W ( 15000 Lumens ) . Luminaire Shall Be Made Up Of Die Cast Aluminium Housing With Pc Lens And Toughened Glass Diffuser. Luminaire Shall Be Designed With Street Optic Lens For Uniform Light Distribution. Lm 80-08 Compliant Leds From Reputed Makes Should Be Provided. Leds Used In The Product Shall Comply With En 62471 For Photo-Biological Safety And Certificate For The Same From Manufacturer Shall Be Provided. Luminaire Shall Be With Ip66 Protection. The Led Shall Be Compliant With Lm80-08 Standard With L70 Life Of 50000 Hrs Tested At Maximum Current ( Complete Lm 80 Test Report For Led Should Be Submitted For 10000 Hrs Of Testing ) . The Leds Used Should Be With Cct Of 5700 K And Cri Of Minimum 70. Led Driver Shall Be Potted, Integrated Type, Multistage, Isolated, Apfc Constant Current-Constant Voltage Operated Driver With Range 120-300V Ac And Safety Extra Low Voltage < 60V Dc As Per Iec Standard., Driver Efficiency > 92% & 4 Kv Internal Surge Protection, Power Factor Greater Than 0.95 And Total Harmonic Distortion ( Thd ) Of Less Than 10% Should Be Integral To The Luminaire. Compliance To Indian Standards Of Is10322 Part 5 / Sect 1:1967; 16105 : 2012; Is 16106 : 2012; Is 15885 ( Part2 / Sec13 ) : 2012; Is 16108 : 2012. 251 Nsr: Supplying Installation Testing & Commissioning Of 20W Led Post Top Light Fixture With System Efficacy Of 100 Lm / W ( 2000 Lumens ) . Luminaire Shall Be Made Up Of Die Cast Aluminium Housing With Pc Lens And Toughened Glass Diffuser. Luminaire Shall Be Designed With Street Optic Lens For Uniform Light Distribution. Lm 80-08 Compliant Leds From Reputed Makes Should Be Provided. Leds Used In The Product Shall Comply With En 62471 For Photo-Biological Safety And Certificate For The Same From Manufacturer Shall Be Provided. Luminaire Shall Be With Ip66 Protection. The Led Shall Be Compliant With Lm80-08 Standard With L70 Life Of 50000 Hrs Tested At Maximum Current ( Complete Lm 80 Test Report For Led Should Be Submitted For 10000 Hrs Of Testing ) . The Leds Used Should Be With Cct Of 5700 K And Cri Of Minimum 70. Led Driver Shall Be Potted, Integrated Type, Multistage, Isolated, Apfc Constant Current-Constant Voltage Operated Driver With Range 120-300V Ac And Safety Extra Low Voltage < 60V Dc As Per Iec Standard., Driver Efficiency > 92% & 4 Kv Internal Surge Protection, Power Factor Greater Than 0.95 And Total Harmonic Distortion ( Thd ) Of Less Than 10% Should Be Integral To The Luminaire. Compliance To Indian Standards Of Is10322 Part 5 / Sect 1:1967; 16105 : 2012; Is 16106 : 2012; Is 15885 ( Part2 / Sec13 ) : 2012; Is 16108 : 2012. 252 Nsr: Supplying Installation Testing & Commissioning Of 10W Bollard Light Fixture With System Efficacy Of 100 Lm / W ( 1000 Lumens ) . Luminaire Shall Be Made Up Of Die Cast Aluminium Housing With Pc Lens And Toughened Glass Diffuser. Luminaire Shall Be Designed With Street Optic Lens For Uniform Light Distribution. Lm 80-08 Compliant Leds From Reputed Makes Should Be Provided. Leds Used In The Product Shall Comply With En 62471 For Photo-Biological Safety And Certificate For The Same From Manufacturer Shall Be Provided. Luminaire Shall Be With Ip66 Protection. The Led Shall Be Compliant With Lm80-08 Standard With L70 Life Of 50000 Hrs Tested At Maximum Current ( Complete Lm 80 Test Report For Led Should Be Submitted For 10000 Hrs Of Testing ) . The Leds Used Should Be With Cct Of 5700 K And Cri Of Minimum 70. Led Driver Shall Be Potted, Integrated Type, Multistage, Isolated, Apfc Constant Current-Constant Voltage Operated Driver With Range 120-300V Ac And Safety Extra Low Voltage < 60V Dc As Per Iec Standard., Driver Efficiency > 92% & 4 Kv Internal Surge Protection, Power Factor Greater Than 0.95 And Total Harmonic Distortion ( Thd ) Of Less Than 10% Should Be Integral To The Luminaire. Compliance To Indian Standards Of Is10322 Part 5 / Sect 1:1967; 16105 : 2012; Is 16106 : 2012; Is 15885 ( Part2 / Sec13 ) : 2012; Is 16108 : 2012. 253 Nsr: Supplying Installation Testing & Commissioning Of Flexible Led Strip Light In 5 Meter Length With 12W / Meter Power Consumption In Façade Area. Luminaire Shall Be With Ip65 Protection. 254 Lighting Pole:Supplying Including Installation Of The Octagonal Poles Shall Be Designed To Withstand Themaximumwind Speed Of 169 Km / Hr. The Top Loading I.E. Area And Weight Of Fixtures Are To Be Considered To Calculate Maximum Deflectionof The Poles And The Same Shall Meet The Requirement Of Bs:5649 Part Vi 1982. The Pole Shaft Shall Have Octagonal Cross Section And Shall Be Continuouslytapered With Single Longitudinal Welding. There Shall Not Be Any Circumferentialwelding Of The Pole Shaft. The Welding Of The Pole Shaft Shall Be Done Bysubmerged Welding Process. All Octagonal Pole Shafts Shall Be Provided With The Rigid Flange Plate Of Suitable Thickness With Provision For Fixing 4 Foundation Bolts. The Baseplate Shall Be Fillet Welded To The Pole Shaft At Two Locations I.E. From Inside And Outside. The Welding Shall Be Done As Per Process Approvedby Third Party Inspection Agency. ( Bajaj / Philips / Valmont / Paruthi Engr / Nezonemake ) Nsr: 3 Meter Pole 255 Nsr: 7 Meter Pole 256 Supplying Including Fitting And Fixing Of Hot Dip Galvanised Arm Bracket For Installation Of Luminaries.Header With Top Cap 300 Mm Long Pipeof Thickness 3 With Arrangementto Fix On Pole Top With 3 Nos. Of Bolts. Iarmed Of Required Length Size 48.3Mm Out Side Dia X 3.25Mm Thickstiffener Plate From Arm Of The Following Types : Nsr: Single Arm Bracket 1500Mm Long For 3M To 10 Metre. Poles. 257 Nsr: Supplying And Erecting Water Tight M.S.Box Of Size20 X 15 X 15 Cm.To Erect Suitable Kitkat Fuse / Mcbto Be . Erected On Polished Wooden Board Inside The Boxwith Hinged / Sliding Door With Rubber Rings And Erected On Pole With Suitable Pole Clamp, All Duly Painted With One Coat Of Red Oxide And Two Coats Of Paints. ( Cost Of Fuse / Mcb Shall Be Taken Extra ) 258 Nsr: Supplying And Installation Of Pole Earthing With 19Mm Dia 1.8 Mtr. Long G.I. Earth Spike 750Mm Distance From Pole At A Depth Of 250 Mm Below Ground Level Complete With 10Mm Dia 50Mm Long G.I. Nut, Bolt, Nuts And Washers Etc. As Reqd. 259 320 Kva Diesel Generator Setnon-Schedule Item:320 Kva Diesel Generator Set:Mahindra 320 Kva ( 3 Phase ) Dg Set With Amf Panel. 260 400 Kva Substation:Analysed Rate: Ajanta Transformers Brand 400 Kv 11 / 0.433 Kv, 3 Phase, 50C / S Copper Wound Distribution Transformer Generally Confirming To Is 1180 ( Part-1 ) And Losses Confirming To 4 Star Rated Transformer Of Bee ( I.E. Total Losses @ 50% Loading: 1225W & At 100% Loading: 3450 W ) And Provided With Standard Fitting And Accessories.I ) 400 Kva, 11 / 0.433 Kv, Vector Group Dyn-11 Aluminium Wound Transformer - 1No. 261 Provision For Security Deposit And Supervision Charges:Load Security Deposit To Be Deposited To Concerned Power Supply Agency Withcheck Meter As Well As Permission From Power Supply Authority Including Liasioning With All The Concerned Departments Etc. 262 Construction Of 3 Phase 11 Kv Line On G.I. Steel Tubular Pole 12M Sp-62 Using Aaa Raccoon Conductor 7 / 3.81Mm With T Cross Arm Average Span 70M. 263 Supervision Charges And Liaision Charges To Be Paid To Power Supply Agency 264 Cctv System Equipment ( Ip ) ( Em Qtr ) :1. Supply, Installation & Commissioning Of Following Cctv System Component1.1 Indoor Ip Base 1 / 3Colorauto Iris Fixed Lense Cmos Cameras ( High Resolution Cameras / Minimum 4Mm Lance / 3 Megapixal / Poe ) Fitted Enclosed In A Discrete Mirror Dome Complete With Sockets As Per Specification And Ir Range Min 30 Meter. 265 1.2: Indoor Ip Base 1 / 3Colorauto Iris Verifocal Lense Cmos Wireless Cameras ( High Resolution Cameras / Minimum 4Mm Lance / 3 Megapixal / Poe ) Fitted Enclosed In A Discrete Mirror Dome Complete With Sockets As Per Specification And Ir Range Min 50 Meter. 266 1.3: Supply, Installation, Testing And Commissioning Of 55 Totally Flat Colour Led Monitor. 267 1.4: Supply, Installation, Testing And Commissioning Of 32 Chanel Network Video Recorder With 2 Sata 268 1.5: 8Tb Survelience Harddisk 269 1.6: Rj Connectors 270 1.7: Hdmi Cable 271 Fire Fighting Work ( For Em Qtr. ) ( Wet Riser System - Pumping Equipments ) :1: Supplying, Installation, Testing And Commissioning Of Electric Driven Terrace Pump Suitable For Automatic Operation And Consisting Of Following, Complete In All Respects, As Required: ( Terrace Pump ) A ) Horizontal Type, Multistage, Centrifugal, Split Casing Pump Of Cast Iron Body & Bronze Impeller With Stainless Steel Shaft, Mechanical Confirming To Is : 1520.B ) Suitable Hp Squirell Cage Induction Motor Tefc Type Suitable For Operation On 415 Volts, 3 Phase, 50 Hz, Ac Supply With Ip55 Class Of Protection For Nclosure, Horiziontal Foot Mounted Type With Class-F Insulation, Conforming To Is-325.C ) M.S.Fabricated Common Base Plate, Coupling, Coupling Guard, Foundation Bolts Etc.As Required.D ) Suitable Cement Concrete Foundation Duly Plastered And With Anti Vibration Pads.4.1: 900 Lpm At 35 M Head 272 20: Supplying And Fixing Air Vessel Made Of 250 Mm Dia, 8 Mm Thick Ms Sheet, 1200 Mm In Height With Air Release Valve On Top And Flanged Connection To Riser, Drain Arrangement With 25 Mm Dia Gun Metal Wheel Valve With Required Accessories, Pressure Gauge And Paintingwith Synthetic Enamel Paint Of Approved Shade As Required. 273 Mr: Supply, Installation, Testing And Commissioning Of Pressure Switches For Hydrant / Diesel Engine Driven Pump / Jockey Pumps, Diaphragm Type, Adjustable Range From 0-9 Bar And A Regulation Range Of 0.1 1.5 Bar Direct Mounted Snap Acting Type Made From Die Cast Aluminium With Epoxy Powder Coated Finish And Ss316 Diaphragm And Other Wetted Parts, Including Necessary Wiring Upto Control Panel & Other Materials As Required As Per Specifications. 274 ( Hydrants System ) :9: Supplying And Fixing Single Headed Internal Hydrant Valve With Instantaneous Gunmetal / Stainless Steel Coupling Of 63 Mm Dia With Cast Iron Wheel Isi Marked Conforming To Is 5290 ( Type -A ) With Blank Gunmetal / Stainless Steel Cap And Chain As Required :9.1: Single Headed Gun Metal 275 16: Supplying And Fixing 63 Mm Dia, 15 M Long Rrl Hose Pipe With 63 Mm Dia Male And Female Couplings Duly Bound With Gi Wire, Rivets Etc. Conforming To Is 636 ( Type-A ) As Required :16.2: Stainless Steel ( Grade 304 ) 276 18: Supplying & Fixing 63 Mm Dia Gun Metal Short Branch Pipe With 20 Mm Nominal Internal Diameter Size Nozzle Conforming To Is 903 Suitable For Instantaneous Connection To Interconnect Hose Pipe Coupling As Required :18.2: Stainless Steel ( Grade 304 ) 277 17: Supplying And Fixing First-Aid Hose Reel With Ms Construction Spray Painted In Post Office Red, Conforming To Is 884 Complete With The Following As Required. ( A ) 20 Mm Nominal Internal Dia Water Hose Thermoplastic ( Textile Reinforced ) Type -2 As Per Is: 12585 ( B ) 20 Mm Nominal Internal Dia Gun Metal Globe Valve & Nozzle. ( C ) Drum And Brackets For Fixing The Equipmets On Wall. ( D ) Connections From Riser With 25 Mm Dia Stop Gun Metal Valve & M.S. Pipe And Socket.E ) 17.2: 40M 278 Mr: Sitc Weather Proof M.S Cabinet Size ( Door Size Only = 1200 Mm X 2100 Mm X 600Mm ) :Supplying, Installation, Testing And Commissioning Ofweather Proof M.S Cabinet Door Size 1200 Mm X 2100 Mm X 600Mm Deepfabricatedfrom 1.6Mmthick M.S. Sheets Andm.S Angle 40Mmx40mmx6mm Complete Withglass, Locking Arrangements To Accommodate The Following: -A ) Gunmetal Singleheadedhydrant Valve - 1 No.B ) Fire Hoses 63Mm, 15 M Long With Accessories - 2 Nos.C ) Short Branch- 1 No.D ) First Aid Hose Reel - 1 No.E ) Fire Extinguisher - 2 Nos.F ) FiremanS Axe - 1 No.G ) Pressure Gauge-1No.The Cabinet Shall Be Painted With Onecoat Ofprimer And 2 Coats Of Synthetic Enamel Paint Ofapproved Shade. 279 19: Supplying And Fixing Of Fire Brigade Connection Of Cast Iron Body With Gun Metal Male Instantaneous Inlet Couplings Complete With Cap And Chain As Reqd. For Suitable Dia Ms Pipe Connection Conforming To Is 904 As Required :19.1: 2 Way-100 Mm Dia M.S. Pipe 280 ( Piping, Valves And Accessories ) :Sltc Of M.S. Pipe On Surface7: Providing, Laying, Testing & Commissioning Of C Class Heavy Duty Ms Pipe Conforming To Is 3589 / Is 1239 Including Welding, Fittings Like Elbows, Tees, Flanges, Tapers, Nuts Bolts, Gaskets Etc. And Fixing The Pipe On The Wall / Ceiling With Suitable Clamp / Support Frame And Painting With Two Or More Coats Of Synthetic Enamel Paint Of Required Shade Complete As Required :7.7: 100 Mm Dia 281 7.6: 80 Mm Dia 282 7.1: 25 Mm Dia 283 11: Supplying, Fixing, Testing And Commissioning Of Butterfly Valve Of Pn 1.6 Rating With Bronze / Gunmetal Seat Duly Isi Marked Complete With Nuts, Bolts, Washers, Gaskets Conforming To Is 13095 Of Following Sizes As Required.11.5: 100 Mm Dia 284 14: Providing, Installation, Testing And Commissioning Of Non-Return Valve Of Following Sizes Confirming To Is: 5312 Complete With Rubber Gasket, Gi Bolts, Nuts, Washers Etc.As Required.14.5: 100 Mm Dia 285 13: Supplying And Fixing Orifice Plate Made Out Of 6 Mm Thick Stainless Steel ( Grade 304 ) With Orifice Of Required Size To Be Fitted Between Flange & Landing Valve Of External And Internal Hydrants To Reduce Pressure At The Outlet To The Level Of 3.5 Kg / Cm2 Complete As Required. 286 Mr: Supply, Installation, Testing And Commissioning Of 150 Mm Dia Bourden Type, Stainless Steel Dial Type Pressure Gauge Including Brass Isolation Valve And Siphon Pipe Having Calibration Of 0 - 16 Kg / Cm2 287 Mr: Supplying And Fixing Of Fire ManS Axe With Heavy Insulated Rubber As Per Standard Conforming To Is 926 288 15: Providing, Installation, Testing And Commissioning Of Stainless Steel Y-Strainer Fabricated Out Of 1.6 Mm Thick Stainless Steel, Grade 304, Sheet With 3 Mm Dia Holes With Stainless Steel Flange.15.2: 100 Mm Dia 289 Mr: Providing & Fixing Double Flanged Metallic Expansion With M.S. Fixed Flanges ( Pn-1.6 ) Joint ( Suitable For System Test Pressure ) Of Standard Length As Per Manufacturers Specs Including Rubber Gaskets, Flanges, Nuts, Bolts And Washers Complete As Required As Per Specifications.100 Mm Dia 290 ( Fire Extinguishers ) :Mr: Supply, Installation, Testing And Commissioning Of Isi Marked ( Is:15638 ) Portable Chemical Fire Extinguisher, Water ( Gas Pressure ) Type Capacity 9 Litres With Gun Metal Cap And Nozzle And Complete In Allrespectsincluding Initial Fill And Wall Suspension Brackets As Required As Per Specifications. 291 Mrproviding And Fixing Fire Extinguisher Of Carbon Dioxide Type Consisting Of Brand New High Pressure Steel Cylinder Bearing Is: 7285 Mark And Having The Approval Of Controller Of Explosives Nagpur, Wheel Type Valve Bearing Is:3224 Mark Internal Discharge Tube, 1 Meter Long High Pressure Discharge Hose, Non Conducting Horn, Suspension Bracket, Fully Charged Bearing Is: Making Fixed To Wall As Directed.4.5Kg Capacity Cylinder 292 Sprinkler With Piping Accessories:7: Providing, Laying, Testing & Commissioning Of C Class Heavy Duty Ms Pipe Conforming To Is 3589 / Is 1239 Including Welding, Fittings Like Elbows, Tees, Flanges, Tapers, Nuts Bolts, Gaskets Etc. And Fixing The Pipe On The Wall / Ceiling With Suitable Clamp / Support Frame And Painting With Two Or More Coats Of Synthetic Enamel Paint Of Required Shade Complete As Required :7.1: 25 Mm Dia 293 7.2: 32 Mm Dia 294 7.3: 40 Mm Dia 295 7.4: 50 Mm Dia 296 7.5: 65 Mm Dia 297 7.6: 80 Mm Dia 298 7.7: 100 Mm Dia 299 11: Supplying, Fixing, Testing And Commissioning Of Butterfly Valve Of Pn 1.6 Rating With Bronze / Gunmetal Seat Duly Isi Marked Complete With Nuts, Bolts, Washers, Gaskets Conforming To Is 13095 Of Following Sizes As Required.11.5: 100 Mm Dia 300 11.2: 50 Mm Dia 301 14: Providing, Installation, Testing And Commissioning Of Non-Return Valve Of Following Sizes Confirming To Is: 5312 Complete With Rubber Gasket, Gi Bolts, Nuts, Washers Etc.As Required.14.5: 100 Mm Dia 302 Non Dsr: Supply, Providing, Fixing, Testing & Commissioning Of Ss Spring Loaded Air Relief Valve For Pressure Of 16 Kg / Sqm Of Approved Quality With Gm Isolation Valve, Tapers, G.I. Pipes And Specials Etc. Including Making Necessary Screwed / Flanged Joints By Providing All Jointing Materials Including Painting And Testing The Joints To Hydraulic Pressures Specified For Pipes All Complete As Per Drawings And As Directed By The Engineer-In-Charge.25 Mm Dia 303 23: Providing & Fixing Flow Switch In Following Sizes M.S. Pipe Including Connection Etc As Required.23.1: 100 Mm Dia 304 21: Providing, Fixing, Testing & Commissioning Of 15Mm Dia Quartzoid Bulb Type Sprinklers Of Rating 68 Degree Centigrade With Required Accessories :21.1: Pendent Sprinkler 305 25: Ss Flexible Braided Pipe For Below False Ceiling Sprinkler ( Ul / Fm Approved ) 800 / 1000 Mm Length ( Optional ) 306 16: Providing And Fixing In Position The Industrial Type Pressure Gauges With Gun Metal / Brass Valves Complete As Required 307 19: Supplying And Fixing Of Fire Brigade Connection Of Cast Iron Body With Gun Metal Male Instantaneous Inlet Couplings Complete With Cap And Chain As Reqd. For Suitable Dia Ms Pipe Connection Conforming To Is 904 As Required :19.1: 2 Way-100 Mm Dia M.S. Pipe 308 Fire Alarm System:Supply, Installation, Testing And Commissioning Of Imported Portion Of The Following Equipment For Fas.Dsr-E&M2018 - Item No. -17.2.1.2: Supplying, Installation, Testingandcommissioningofmicro Processorbasedintelligentaddressablemainfirealarm Panel, Centralprocessingunitwiththefollowingloop Modules And Capable Of Supporting Not Less Than 240 Devicesincludingdetectors ) Andminimum120detectorsperloop Andlooplengthupto2km, Networkcommunicationcard, Minimum320charactergraphics / Lcddisplaywithtouch Screen Or Other Keypad And Minimum 4000 Events History Log In The Non Volatile Memory ( Eprom ) , Power Supply Unit ( 230 ±5%V, 50Hz ) , 48Hrsback-Upwith24voltsealed Maintenancefreebatterieswithautomaticcharger.The Panel Shall Have Facility To Connect Printer To Printout Log And Facility To Have Seamless Integration With Analog / Digital Voice Evacuationsystem ( Whichispartofthescheduleofwork Undersh:Pasystem ) Andshallbecompletewithall Accessories . The Panel Shall Be Compatible For Ibms System With Open Protocol Bacnet / Modbus Over Ip Complete As Per Specifications. Two Loop Panel. 309 Dsr-E&M2018 - Item No. -17.2.2: Supplying, Installation, Testing&Commissioningofcentral Graphical Fire Alarm Management System To Centrally Monitor And Operate The Fire Alarm System Complete As Required. 310 Dsr-E&M2018 - Item No. -17.2.3: Supplying, Installation, Testing&Commissioningofrepeater Panel Wih 320 Haracter / Touch Screen Lcd Display With Inbuilt Reset, Acknowledge And Silence Switches Complete As Required. 311 Non Dsr: Addressable Monitoring Module ( Inbuilt With Two Nos Fault Isolator ) To Connect No / Nc Contacts Such As Pressure Switch, Flow Switches, Fire Pump Contacts ( Provided By Fire Fighting Contractor ) .However Testing And Commissioning Shall Be Included In The Fire Detection And Alarm Systemcontractor Scope. Panel Shall Be Located At Security Room And Reception Area. 312 Dsr-E&M2018 - Item No. -17.2.10: Supplying, Installation, Testing&Commissioningof Addressable Fire Control Module Complete As Required. 313 Dsr-E&M2018 - Item No. -17.2.4: Supplying, Installation, Testing & Commissioningof Intelligent Analogaddressablephotothermaldetectorcompletewith Mounting Base Complete As Required. 314 Dsr-E&M2018 - Item No. -17.2.6: Supplying, Installation, Testing&Commisssioningof Intelligentaddressableprogrammablesoundercompleteas Required. 315 Dsr-E&M2018 - Item No. -17.2.9: Supplying, Installation, Testing & Commissioning Of Intelligent Addressablethermaldetectorwithrateofrisecumfixed Tempreature Thermistor Complete With Base As Required. 316 Dsr-E&M2018 - Item No. -17.2.14: Supplying, Installation, Testing&Commissioningof Addressable Manual Call Point Complete As Required. 317 Dsr-E&M2018 - Item No. -17.2.7: Supplying, Installation, Testing&Commissioningoffault Isolator Complete With Base As Required. 318 Dsr-E&M2018 - Item No. -17.2.15: Supplying, Installation, Testing&Commissioningof Addressable Horn Cum Strobe Complete As Required. 319 Dsr-E&M2018 - Item No. -17.2.11: Supplying, Installation, Testing&Commissioningof Addressable Phone Control Module Complete As Required. 320 Dsr-E&M2018 - Item No. -17.2.19: Supplying, Installation, Testing & Commissioning Of Fire Fighter Phone Jack Complete As Required. 321 Dsr-E&M2018 - Item No. -17.2.5: Supplying, Installation, Testing & Commissioning Of Response Indicatoronsurface / Recessedmsboxhavingtwoled, Metallic Cover Complete With All Connections Etc As Required. 322 Dsr-E&M2018 - Item No. -17.2.17: Supplying, Installation, Testing & Commissioning Of Fire Fighter Telephone Handset Complete As Required. 323 Cables And Accessories:Dsr-E&M2018 - Item No. -17.5.2: Supplying & Laying Of 2X1.5 Sqmm Fire Alarm Armoured Cable, 600 / 1000Vratedwithannealedcopperconductorhaving Xlpeinsulation, Steelwirearmouring&Frlsoutersheath Complete As Required. 324 Providing And Fixing Furniture In Each Flat From 1St Floor To Terrace Of The Following Items Of Specified Brand / Make All Complete As Directed By The Engineer-In-Charge::2 Seater Sofa Model: Perry / A / 2 +, 3 Seater Sofa Model: 3 Seater Leather Sofa, Centre Table Model:Winter / Ct, Side Table Model: Eero / B / St, Low Height Units Model: Catherine / Console, Garden Chair And Table Model: Brighton, Tv Unit Model: Catherine / Tv, 6 Seater Dining Table Model: Siberian, Garden Chair And Table Model: Brighton, Double Bed, Side Table Near Bed Garren / Nt, Arm Chair: Beverly, Garden Chair And Table: Brenton, Coffee Table: Scarlet / Cttv Unit: Scarlet / Tv, Wardrobe: Nina-900A / 2D ( Height - 8Ft. ) , Double Bed Queen Size:Hamilton / Qb, Side Table Naer Bed: Winston / Nt, Arm Chair: Gemini, Tv Unit: Casper / Tv, Garden Chair And Table: Brenton, Wardrobe: Robinson-900A / 2D ( Height - 8Ft. ) , Double Bed: Mark Plus / Kb, Side Table Near Bed:Mark Plus / Nt / R, Side Table:Polka, 2 Seater Sofa: Andrea / 2, Dresser: Mark-I / Dre / A / Stl, Tv Unit:Cole, Garden Chair And Table: Brenton, Wardrobe: Mark-900A / 2D ( Height - 8Ft. ) , Arm Chair:Clement / 1 / L-37, 2 Seater Sofa:Elton / B / 2, Chair:Marvel / Mb / Premium, Desk:Theon / B, Side Table:Molly / St, 3 Seater Sofa:Skyler / A / 3, Centre Table:Siberian / Ct, Office Chair:Halx / 37199, Arm Chair:Clement / 1 / L-37, Side Table:Scarlet / St, Visitor Chair:Marvel / Mb / Premium, Office Desk: Mjf / 61101 / B, Low Height Units:Mjf Back Unit, Single Bed:Leeds Single Bed, Wardrobe: Rick ( Height - 6Ft. ) , Single Bed:Leeds Single Bed, Desk:Alston, Chair:Marvel / Mb / Premium, Wardrobe:Rick ( Height - 6Ft. ) 325 Providing And Fixing Furniture At Ground Floor Of The Following Items Of Specified Brand / Make All Complete As Directed By The Engineer-In-Charge::2 Seater Sofa: Elton / B / 2 Seater , 3 Seater Sofa: 3 Seater Sofa, Centre Table: Ivara, Side Table: Carlos, Reception Table: Theon / B, Low Height Storage: Theon / C, Visitor Chair: Marvel / Mb / Premium, Office Chair:Marvel / Hb / Premium, Arm Chair:Rachel, Arm Chair:Hemingway / 1, Centre Table:Catherine / Ct, Tv Unit:Catherine / Tv, Pantry Table:Catherine / Console, 12 Seater Conference Table: Meridian / D ( Seating Capacity - 8 Person ) , Low Height Storage:Meridian / E, Office Chair:Marvel / Hb / Premium, Visitor Chair: Marvel / Mb / Premium, Office Desk:Theon / B, 4 Seater Dining Table:Nero / A ( Rectangular ) , 2 Seater Dining Table:Brighton ( Round ) , Library Shelves:Dws / 34760, Table:Theon / B, 4 Seater Dining Table:Nero / A ( Rectangular ) , 2 Seater Dining Table:Brighton ( Round ) , Visitors Chair:Marvel / Mb / Premium, Office Chair:Marvel / Hb / Premium, Office Table:Theon / B, Low Height Storage: Theon / C, Shelves:Dws / 34760, 3 Seater Sofa: Elton / B / 3, Arm Chair:Rachel, Tv Unit:Emma / Tv, Centre Table:Emma / Ct, Single Beds:Leeds Single Bed, Small Side Table:Bolton / Nt, Wardrobe: Rick ( Height - 6Ft. ) , Chair: Marvel / Hb / Premium, Table:Theon / B, 4 Seater Dining Table: Nero / A ( Rectangular ) , Low Height Storage:Rick ( Height - 6Ft. ) , Visitor Chair:Marvel / Mb / Premium, Office Chair:Marvel / Hb / Premium, Office Desk:Theon / B. 326 Providing Supply, Fitting And Installation Air Conditioning Complete And As Directed:I ) Mitsubishi Make 2 Tr Inverter Cassette Unit, Ii ) Mitsubishi Make 3 Tr Inverter Cassette Unit, Iii ) Mitsubishi Make 3.5 Tr Inverter Cassette Unit, Iv ) Mitsubishi Make 1 Tr Hiwall Inverter Split Unit, V ) Mitsubishi Make 1.5 Tr Hiwall Inverter Split Unit, Vi ) Mitsubishi Make 2 Tr Hiwall Inverter Split Unit, Vii ) For Cassette Unit Refrigerant Copper Piping15.86 Mm Dia ( Od ) ( Soft Drawn ) With Tube Thickness 1.2 Mm With 19Mm Thick Insulation, Viii ) For Cassette Unit Refrigerant Copper Piping9.53 Mm Dia ( Od ) ( Hard Drawn ) With Tube Thickness 1.2 Mm With 19Mm Thick Insulation, Ix ) For Hiwall Split Unit Refrigerant Copper Piping, X ) Supply & Installation Of Cpvc Piping Complete With Fit- Tings, Supports And Duly Insulated With 9 Mm Thick Closed Cell Class-O Nitral Rubber Insulation. 25 Mm Dia Drain Pipe, Xi ) Gas Charging ( R-410 ) , Xii ) 4Core X 2.5 Sq. Mm For Cassette And Split Ac, Xiii ) Odu Stand For Split Unit, Xiv ) Odu Ms Angle For Cassette Unit, Xv ) Installation, Testing Commissioning Charge:2 Tr Cassette Unit , Xvi ) 3 Tr Cassette Unit , Xvii ) 4 Tr Cassette Unit And Xviii ) Hiwall Inverter Split Unit 327 Providing Supply, Fitting And Fixing Gym Equipment Complete As Directed And Specified By The Engineer-In-Charge:1 ) Treadmill Af 103, 2 ) Cross Trainer 246 El, 3 ) Lat Pull Down / Seated Row Af 4501 , 4 ) Leg Extension / Leg Curl Af 4500, 5 ) Rear Delt / Pec Fly – ( So ) Af 4414, 6 ) Functional Trainer Af 9914, 7 ) Leg Press Hack Squat Af 2916, 8 ) Olympic Flat Bench Indian, 9 ) Multi Bench Indian, 10 ) Flat Bench, 11 ) Hyper Extension, 12 ) Dips, 13 ) Seated Calf, 14 ) Dumbbell Rack, 15 ) Plate Tree, 16 ) Dumbbell Indian, 17 ) Plate Indian, 18 ) Olympic Bar 7 Fit, 19 ) Olympic Bar 5 Fit, 20 ) Olympic Bar 4 Fit, 21 ) Olympic Bar 3 Fit, 22 ) Olympic Bar Ez 4Fit, 23 ) Olympic Bar 3 Fit, 24 ) Bicep Bench, 25 ) Short Bar 101, 26 ) Curl Bar 020 , 27 ) Arc Handle Pull Bar 108, 28 ) Arc Handle Keep 114, 29 ) Shoulder Rope Single, 30 ) Lat Bar 17, 31 ) Smith Machine, 32 ) Gym Ball, 33 ) 5Mm Yoga Mat. 328 Providing And Fixing Jacuzzi Of The Following As Directed And Specified Complete:I ) Artize Quadro; 190 X 90 X 50 Superior Whirlpool; Model- Awl-Wht-Supr190x90, Ii ) Lexa And Quadro Front Panel Suitable For Lexa And Quadro Bathtube; Model- Awa-Gry-Fp190x, Iii ) Quadro Side Panel Suitable For Built-In Bathtub & Whirlpool.
Contract Date : 31 Dec, 2022   |   Contract Value : 44.72 Crore
BRR : 9519259 Tender For Construction Of Divisional Office Building Vellore At Fsd Sevur Tamil Nadu Region (Recall).; 1 Civil ( S.No.1-96) Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared 2 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead upto 50m and for all lift as directed by Engineer-in-Charge. a) All kind of soil. 3 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. 4 Supplying and filling in plinth withsand under floors, including watering, ramming,consolidating and dressing complete. 5 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: a) 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40mm nominal size derived from natural sources) 6 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (1 cement : 2 coarse sand (zone-iii) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) 7 Treatment of soil using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With chlorpyriphos/lindane E.c. 20% with 1% concentration 8 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work;usingcoarse aggregate and fine aggregate derived from natural sources,portland pozzolana / ordinary portland /portland Slagcement,admixtures in recommended proportions as per iS: 9103 to accelerate /retard setting of concrete, to improve durability andworkabilitywithout impairing strength; including pumping of concrete to site of laying, curing,carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge;for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately.in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 1)concrete of m30 grade withminimum cementcontent of 350 kg /cuma) All works upto plinth level 9 b)All works above plinth level upto floor V level 10 Centering and shuttering including strutting, propping etc. and removal of form for all heights.a) Foundations, footings, bases of columns. etc. for mass concrete 11 b) Lintels, beams, plinth beams, girders, bressumers and cantilevers 12 c) Suspended floors, roofs, landings, balconies and access platform 13 d) Columns, Pillars, Piers, Abutments, Posts and Struts 14 Stairs, (excluding landings) except spiral-staircases 15 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.a) Thermo-Mechanically Treated bars of grade Fe-500D or more 16 Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) 17 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : a)Cement mortar 1:6 (1 cement : 6 coarse sand) 18 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. a)Cement mortar 1:4 (1 cement :4 coarse sand) 19 12 mm cement plaster a) 1:6(1 cement: 6 fine sand) 20 15 mm cement plaster on rough side of single or half brick wall of mix: a) 1:4 (1 cement: 4 fine sand) 21 20 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand) 22 18 mm thick moulded cement mortar band in two coats under layer 12 mm thick with cement mortar 1:5 (1 cement : 5 coarse sand) top layer 6 mm thick with cement mortar 1:4 (1 cement : 4 fine sand). 23 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shades, laid on 20mm thick cement mortar 1:4 (1 cement:4 coarse sand), jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete. size of the tile 600x600 mm 24 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved brand & manufacturer, in all colours & shade, laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement & matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only, laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish of size b) Size of Tile 600x600 mm 25 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 26 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. a)Polished Granite stone slab of colour Black, Cherry/Ruby Red or equivalent 27 Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : 28 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete.a) On steel work 29 Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture 30 Polishing in high gloss/matt finish melamine clear polish on wood work in required color/ wooden shade texture with following process in the sequence as detailed below:1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos.2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/ grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) 31 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 32 Finishing with Deluxe Multi surface paint system for interiors using Primer as per manufacturers specifications :Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm 33 Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) 34 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 35 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding 36 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 37 Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated ‘J’ or ‘L’ hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 2 mm thick corrugated (2.5” or 4.2” or 6”) or step-down (2” or 3” or 6” ) as specified 38 Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced withgalvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware,SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleevefor fixing frame to finished wall as perIS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof Silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paidseparately.Note:- Structural design proof checked from a Government Engineering Institute,to be provided by the manufacturer for : (i) Siteswith basic wind speed > 45 m/sec as per IS 875 – Part 3(ii)Sites with structure height more than 20m for all wind speeds Two track two panels sliding window with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. Using R2 series with frame (40mm & above) x (40mm & above) & sash (25mm & above) x (50mm & above) with zinc alloy (zamak) powder coated touch locks with hook (Height upto 1.2 metre). 39 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms)fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread offlame of Class Acategorywith property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance indimensions i.edepth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. a)Frame size 50 x 125 mm 40 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate andnatural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimumcompressive strength50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread offlame of Class Acategory with property of being termite/borer proof, water/ moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) a)35 mm thick 41 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood 42 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matchedteak 3 ply veneering with vertical grains or cross bands and face veneers on both faces ofshutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 43 Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) On one side only 44 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters. 45 Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured) 46 Providng & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with: 5.5 mm thick glass panes 47 Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure ation & drainage and protection against fire hazard including:(b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.(c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment , including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.(d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. (e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge.The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for cupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge.Note:- 2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified boratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NBL Certified laboratories (1) Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr (2) Static Water Penetration Test. (50pa to 0pa) as per ASTME- 331-09 testing method for a range up to 2000 ml. (3) Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml (4) Structural Performance Deflection and formation by static air pressure test (1.5 times desing wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm (5) Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for ualitative test. Tests to be conducted on site. (6) Onsite Test for Water Leakage for a ssure range 50 kpa to 240 kpa (35psi) upto 2000 mlNote:- 2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified boratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NBL Certified laboratories (1) Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr (2) Static Water Penetration Test. (50pa to 0pa) as per ASTME- 331-09 testing method for a range up to 2000 ml. 48 Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including:(a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design.(b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc.(c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places. 49 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). 50 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). 51 Extra for providing frosted glass panes 4 mm thick (weight not less than 10 kg per sqm) instead of ordinary float glass panes 4 mm thick(weight not less than 10 kg per sqm) in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured). 52 Providing and fixing stainless steel fancy handle of approved make fixed with SS screws etc. complete as per direction of Engineer-in-charge.a)200 mm 53 Providing and fixing Godrej Stainless Steel Glass to Glass Round Lock 7780 complete as per direction of Engineer-incharge. 54 Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type) 55 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 250x10 mm 56 Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and pair of lever handles of approved quality with necessary screws etc. complete. 57 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less thangrade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 58 Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance ≥ 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizont al level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mmthick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thicksheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge. 59 Full ht. 75 mm. thk Solid Partitions/Semi Glazed Partitions with both side 12mm commercial plywood and 1mm thick Laminate & Providing Aluminium frame of size 50x50x1.8 mm thk (finished) comprising of horizontals and verticals at, 600 mm c/c ,vertically and horizontally fixed firmly to walls / floors / RCC roof etc. Alternate vertical members to go upto RCC ceiling and firmly fixed. Providing 8 mm thk. ISI grade plywood of approved make , finished / fixed with 1 mm thick laminate of approved make & shade fixed with adhesive , fixed on both sides of the partition framework. The laminate to be fixed with adhesive on both sides of the partition upto False ceiling level. 60 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of followingoperations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treatingsimilarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved byEngineer-in-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer ofplaster and finally finishing the surface with trowel with neat cement slurry and making patternof 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : 22.7.1 With average thickness of 120 mm and minimum thickness at khurra as 65 mm. 61 Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. 62 Providing & applying patterened texture work on extrenal wall with birla or equivalent brand putty on plastered surface as approved by Engineer-in-Charge, 63 Providing and fixing of FRP Security Cabin in Size of 2.5x2.5x2.5m with M.S frame structure and covered by FRP Pannel and FRP Pyramid shape Plane Roof. FRP Door thick - 20mm (6x2) With, ALdrop, Handel, & 3 Nos. SS Ingies.Inside & Outside writing Counter, Size- L-4x W-11Electrical Point- Inside &Outside Bulb Point, 1plug, 3 Switch,Cloth Hanger- 01Nos as per Engineer in Charge. 64 PLUMBING Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : A) W.C. pan with ISI marked white solid plastic seat and lid 65 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board, 510x1040 mm bowl depth 225 mm 66 Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : (Size 600x450x200 mm) 67 Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required : White vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps. 68 Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings 69 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. 70 Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. 71 Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6mm thick hard board backing:Oval shape 450x350mm (outer dimensions) 72 Providing and fixing toilet paper holder : C.P. brass 73 Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete.100mm dia Sand cast iron S&S as per IS-1729 74 Providing and fixing soil,waste and vent pipes: Centrifugally cast (spun) iron socketed pipe as per IS: 3989. 75mm dia 75 Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete.100mm dia Hubles centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905. 76 Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete.75 mm dia Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905. 77 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. 78 Providing and fixing Chlorinated Polyvinyl (CPVC) pipes, having thermal stability for hot &cold water supply including all CPVC plain & brass threaded fittingsi/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes &fittings with one steps CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge. Concealed work including cutting chases and making good the walls etc. 20 mm nominal Inner dia Pipes 79 Providing and fixing Chlorinated Polyvinyl (CPVC) pipes, having thermal stability for hot &cold water supply including all CPVC plain & brass threaded fittingsi/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes &fittings with one steps CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge. Concealed work including cutting chases and making good the walls etc.25 mm nominal outer dia Pipes 80 Providing and fixing Chlorinated Polyvinyl (CPVC) pipes, having thermal stability for hot &cold water supply including all CPVC plain & brass threaded fittingsi/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes &fittings with one steps CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge. Concealed work including cutting chases and making good the walls etc. 32 mm nominal outer dia Pipes 81 Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. 82 Providing and placing on terrace (at all floor levels) polythylene water storage tank, IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 83 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size ) , including necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 84 EXTERNAL INFRASTRUCTUREConstruction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in Charge. a)With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30 85 Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. 86 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured to calculate volume for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). Size of 100x0.375x0.20 87 Supplying and stacking of good earth at site including royalty and carriage upto 5 km lead complete (earth measured in stacks will be reduced by 20% for payment). 88 Supplying and stacking at site dump manure from approved source, including carriage upto 5 km lead complete (manure measured in stacks will be reduced by 8% for payment) :Screened through sieve of I.S. designation 16 mm 89 Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge 90 Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately). 91 Fine dressing of the ground 92 Providing & laying Selection no. 1 doob grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same maintenance for 30 days or more till the grass establish properly,as per direction of officer in charge 93 Providing and stacking of Delonix regia (Gulmohar) of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.v 94 Providing and stacking of Plumeria acutifolia of height 120-135 cm. with 2-3 branches in HDPE bag of size 30 cm as per direction of the officer-in-charge. 95 Providing and stacking of Bougainvillea (Variety Butiana, Lady Mary Baring, Mahara,Mohan,Scarlet Queen, Variegated, Glabra Formosa, Peruviana Odissi, Paratha, Subhra,Thimma, Spectabilis L.N Birla, Refulgens) of height 30 cm. to 45 cm. with 2-3 branches in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge 96 Washingtonia filifea palm stem ht. 90-105 cm with 6-7 healthy leaves lush green leaves well developed in big size HDPE Bag 97 Electrical ( S.No.97-211) Supplying of PVC/XLPE armoured cable with aluminium conductor 1.1KV Gradeconfirming to IS 7098 (part I)1988 with upto date amendments of the following size at the site of work3 1/2 X 120 Sq.mm 98 3 1/2 X 70 Sq.mm 99 4 X 25 Sq.mm 100 4 X 10 Sq.mm 101 Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness 102 150 mm width X 50 mm depth X 1.6 mm thickness 103 Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness 104 150 mm width X 50 mm depth X 1.6 mm thickness 105 Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness 106 150 mm width X 50 mm depth X 1.6 mm thickness 107 Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required.100 mm dia 108 Supplying and fixing of light class G.I. pipe of 100 mm dia.(nominal) 3 metres length along the pole for protection of under ground cable as required. 109 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench as required but excluding sand cushioning and protective coveringUpto 35 sq. mm 110 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 95 sq. mm and upto 185sq. mm 111 Up to 35 Sq mm 112 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) 113 Upto 35 sq. mm (clamped with 1mm thick saddle) 114 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on cable tray as requiredAbove 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) 115 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) 116 Upto 35 sq. mm (clamped with 1mm thick saddle) 117 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 120 sq. mm (45mm) 118 3½ X 70 sq. mm (38mm) 119 4 X 25 sq. mm (28mm) 120 4 X 10sq. mm (25mm) 121 Supplying and fixing hot press molded SMC box of size 140x140x95 mm outside with suitable clamps to the wall/pole/truss/GI Pipe, including providing and fixing of 3 way connectors of suitable rating ,providing and fixing 6A C curve MCB, terminating the incoming and out going cables /wires (but with out end termination glands) making connections etc. as required 122 Supplying and fixing of follwing way sueface / recess mounting vertical type , 415 V , TPN MCB distribution board of sheet steel, dust protected , duly painted , inclusive of 200 A tinned copper bus bar , common neutral link , earth bar , for mounting MCBs (but without MCBs and incomer ) as required4 way ( 4 + 12 ) , Double door 123 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But withoutMCB/RCCB/Isolator)8 way (4 + 24), Double door 124 6 way (4 + 18), Double door 125 4 way (4 + 12 ), Double door 126 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 127 Triple pole 128 Supplying and fixing following rating, four pole, 415V isolator in the existing MCB DB complete with connection , testing and commissioning etc. as required 40A 129 63 A 130 Providing and fixing following rating and breaking capacity and pole MCCb with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel making connections , etc as required100 A, 30 KA, FP MCCB 131 Supplying & fixing suitable size GI box with modular plate and cover in fornt on surface or in recess including providing and fixing 25A modular socketoutlet and 25A modular SP MCB , Ccurve includingconnections , painting etc , as required . 132 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C 133 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 134 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 135 4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire 136 4 X 4 sq. mm + 2 X 4 sq. mm earth wire 137 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 138 Supply and Fixing suitable size GI box with modular plate and cover in front on surface or in recess, inculing providing and fixing 3pin 5/6 A modular socket outlet and 5/6 modular swith connections etc.as required . 139 Supply and Fixing suitable size GI box with modular plate and cover in front on surface or in recess, inculing providing and fixing 6pin 5/6 A & 15/16 modular socket outlet and 5/6 modular swith connections etc.as required . 140 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch 141 3 pin 5/6 A socket outlet 142 15/16 A switch 143 6 pin 15/16 A socket outlet 144 Telephone socket outlet 145 RJ45 computer socket cat 6 146 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.8 Module (125mm X 125mm) 147 6 Module (200mm X 75mm) 148 1 or 2 Module (75mm X 75mm) 149 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm 150 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.1 run of cable 151 2 run of cable 152 3 run of cable 153 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.1 Pair 154 2 Pair 155 Earthing with G.I. earth plate 600 mm X 600 mm X 6mm thick including accessories, and Providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre longetc . With charcoal coke and salt as equired 156 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 157 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess For connections etc. as required. 158 Providing and fixing 6 SWG dia G.I. wire on surface or in recess For loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. 159 Earthing with copper earth plate 600 mm X 600 mm X 3mm thick including accessories, and Providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre longetc . With charcoal coke and salt as equired 160 Providing and fixing 4.00 mm dia copper wire on surface or in recess For loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. 161 Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I tube, having single prong at top, with 85 mm dia 6 mm thick . base plate including holes etc. complete as required. 162 Jointing copper / G.I tape (with another copper / G.I tape, base of the final or any other metallic object ) by riveting / nut bolting / sweating and soldering etc as required 163 Providing and fixing G.I tape 20mm X 3mm thick on parapet or surface of wall For lightning conductor complete as required (For horizontal run) 164 Providing and fixing G.I tape 20mm X 3mm thick on parapet or surface of wall For lightning conductor complete as required(For vertical run) 165 Providing and fixing testing joint , made of 20 mm X 3 mm thick G.I. strip , 125mm long , with 4 Each. of G.I bolts, nuts, chuck nuts and spring washers etc. complete as required. 166 Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required . 167 Supplying, installation, Testing and commissioning of 90W LED Street light fittingmade up of pressure die cast aluminium housing with high efficiency LEDs as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 in the existing streetlight pole with suitable clamps and nut bolts including giving connection etc., at site of work as required 168 Supplying, installation, Testing and commissioning of 36 watt 2X2 LED flat panel recess mounting luminaire with high brightness LED as light source, suitable for Armstrong/Grid ceiling and fixing on ceiling with suitable hanging chains, clamps and nut bolts including giving connection testing etc., at site of work as required 169 Supplying, installation, Testing and commissioning of 12 watt Round surface mounted LED panel light fitting made of pressure die-cast aluminium luminaire and high translucent frosted plastic diffuser and fixing on ceiling with suitable clamps and nut bolts including giving connection etc., at site of work as required. 170 Supplying, installation, Testing and commissioning of 18 watt Round surface mounted LED panel light fitting made of pressure die-cast aluminium luminaire and high translucent frosted plastic diffuser and fixing on ceiling with suitable clamps and nut bolts including giving connection etc., at site of work as required. 171 Supplying, installation, testing andcommissioningof 20W LED T8 tubelight with Al body, PC diffuser and inbuilt driver along with Highly robust box type luminare suitable for single T8 LED tube and fixing on wall/ceiling by using necessary clamps etc., at the site of work as required 172 Supplying, installation, testing and commissioning of 20W LED tube alongwith Industrial Batten of Environmental friendly, long life, corrosion resistant, impact proof, surface mounting IP66 luminaire with PC housing & opal finish cover suitable for single T8 LED tubelight and fixing on wall/truss by using necessary clamps etc. as required 173 Supply and fixing of7W LED surface mounted LED mirror light luminarie complete and fixing on wall by using necessary clamps etc., at the site of work as required 174 Supplying, installation, Testing and commissioning of 24 watt square surface mounted LED panel light fitting made of pressure die-cast aluminium luminaire and high translucent frosted plastic diffuser and fixing on ceiling with suitable clamps and nut bolts including giving connection etc., at site of work as required. 175 Supplying, installation, Testing and commissioning of 40 watt LED 5700K Post top lantern IP65 with high power LEDs as light source and fixing on pole with suitable clamps and nut bolts including giving connection testing etc., at site of work as required 176 Supply and fixing of 10W pressure die cast aluminium housing Bulk Head LED fitting with IP66 protected withPVC unsheathed copper leads from terminals to the fitting and fixing on ceiling with suitable clamps and nut bolts including giving connection etc., at site of work as required. 177 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise = 75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. (DSR Item for BEE 5 star rated Ceiling fan with Brush Less Direct Current (BLDC) motor 178 Supplying and fixing of single phase, 230V,50Hz, 1800 rpm, 200mm dia sweep, 5 blade Exhaust fan with bird screen for protection against birds & Foreign material and fixing on the wall surface including giving connections etc. at site of work as required 179 Supply of 6 mtr high hot dipped galvanised octagonal poles with 130 mm bottom dia and 70 mm top dia made up of 3mm thick HT sheet along with base plate of size 200x200x16 mm thick along with 4 nos of M20x600 mm high J type 8 EN grade foundation bolts along with template to fix the pole to the foundation and supply of 1 mtr long hot dipped galvanised single arm bracket made up of 40NB dia GI pipe suitable to mount on pole having top 70 mm dia for mounting the street light fixture 180 Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregrate 40mm nominal size) foundation including excavation and refliing etc. as required 181 Supply, installation, testing and commissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.1.2 TR 182 2.0 TR 183 2.8 TR 184 Supply, Installation, Testing and Commissioning of 1.5 Ton/4500 Kcal/hr, 5 Star Rating Inverter technology High wall split type Air Conditioner with minimum of 3 metre length of copper Refrigerant piping with insulation and electrical cable complete with indoor unit (IDU), Outdoor unit (ODU) suitable For 230V +10% of 50 Hz, single phase AC supply and Fixing on the wall surface including giving connections etc. at site of work as required 185 Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. 186 Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required19 mm dia (OD) (Hard drawn) with tube thickness 1.2mm with 19mm thick insulation 187 34.9 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation 188 Supply and fixing of FP sheet enclosure on surface/recess along with 63A FP C curve MCB complete with connections, testing and commissioning etc. as required 189 Design, Fabrication,Supplying, Installation, Testing and commissioning of Dust and vermin proof Cubicle type LT panel boardsuitable For 3 Phase,415V,50 Hz 4 Wire AC Supply System fabricated in compartmentalized System made out of 14 SWG CRCA Sheet Steel and painted with powder coating in approved shade and comprising of the following:Complete with aluminium busbars ofadequate capacity For Phases & neutral (min. of 250A), Suitable M.S Angle Base Frame, cable alley, interconnections control wiring, including incoming and outgoing cables connections etc as required at site of work and as directed by the Engineer in charge. 190 Design, Fabrication, Supplying, Installation, Testing and commissioning of 315A near by control box with 4 pole 315 A MCCB switch with front handleDust and vermin proof Cubicle type LT panel boardsuitable for 3 Phase,415V,50 Hz 4 Wire AC Supply System fabricated in compartmentalized System made out of 14 SWG CRCA Sheet Steel and painted with powder coating in approved shade and comprising of the following:Complete with aluminium busbars ofadequate capacity for Phases & neutral (min. of 250 A), Suitable M.S Angle Base Frame, cable alley, interconnections control wiring, including incoming and outgoing cables connections etc as required at site of work and as directed by the Engineer in charge 191 Design, Fabrication, Supply, installation, testing and commissioning of 30KVAR Automatic power factor correction panel (APFC) with 6steps of capacitor switching cubicle type, free standing, Powder coated, 14 SWG CRCA sheet steel,enclosed separate compartment For each capacitor, front operated, indoor type dust and vermin proof, hinged, lockable doors, electrolytic grade aluminium bus bars, with SMC /DMC insulator supports, Digital volt meter, Ammeter with selector switch, 6 stage Digital Automatic power factor correction,( APFC ), Auto / Manual selector switch, cluster LED typeindicators, in the incomer,complete with electrolytic grade aluminium bus bars. capacStart, Stop, push buttons, internal wiring, colour coding, ferrules, cable gland plates, Aluminium earth bus For the entire length of the panel with bonding to earth and painting,Panel mounting MS Channels, fasteners, etc., including all associated control wiring and interlocking circuitry, MV panel sensing CT interconnecting wiring etc., complete 192 Supply, Erection, testing and commisioning of 82.5KVA/66 KW Diesel Generating Set (as per the latest CPCB IV+ norms) comprising of Water Cooled, 4 cylinder Diesel engine developing minimum of 102 BHP with electric start compression ignition 4 stroke designed to run continuously at at 1500 RPM. Coupled to Alternator rated at 1500 rpm, 415 Volts, 0.8 power factor, 50 Hz, three phase supply, self-excited and self-regulated, brushless, floor mounted with ball or bearings on end shields and fuel Tank of minimum 150 Ltrs capacity with Standard Control Panel with Breaker, Batteries and Acoustic Enclosure including Transportation, loading-Unloading, UG cable laying from generator to panel, earth strips connections etc., at the site of work as required (Model should have minimum 2 year warranty) 193 Supply, Installation, Testing and Commissioning of 15kVA DOUBLE CONVERSION 3 phase input,3 phase output True Sinewave ONLINE UPS with 0.99 power factor including stand along with supply and erection of 12V/26AH SMF Batteries (30mis back up) of 30 nos.including providing necessary connections etc. complete as required 194 Supplying, fixing and testing of CO2 fire extinguisher of 4.5 kg capacity with hose and horn confirming to relevant ISI specification including fixing on suitable wall mount bracket/ clamp/ hook and nuts,bolts etc., at the site of work as required. 195 Supplying, fixing and testing of ABC Fire Extinguishers Filled with Mono Ammonium Phosphate Dry Powder of 10 kg capacity suitable For all Types of Fires confirming to relevant ISI specification including fixing on suitable wall mount bracket/ clamp/ hook and nuts,bolts etc., at the site of work as required. 196 Supplying, fixing and testing of ABC Fire Extinguishers Filled with Mono Ammonium Phosphate Dry Powder of 6 kg capacity suitable For all Types of Fires confirming to relevant ISI specification including fixing on suitable wall mount bracket/ clamp/ hook and nuts,bolts etc., at the site of work as required. 197 Supplying and fixing of MS angle fire bucket stand with 03 Each fire buckets of 10 litre capacity, at the site of work as required. 198 Supplying, installation, testing and commissioning ofsmoke detection system with minimum of 36 Each conventional type photo-electric smoke detectors, 2x1.5 sq.mm fire resistant armoured cable(red colour), 6 Each Manual Call points, 6 Each Hooters complete with 2 zone fire alarm panel etc at site of work as required 199 Supply, Installation, Testing and commissioning of 16 channel 4 SATA NVR, with 4T Hard Disk Drive 1 Each, New logical and visualized GUI design Dual-OS design to ensure high reliability of system running, ANR technology to enhance the storage reliability when the network is disconnected,Configurable normal or hot spare working mode to constitute an N+1 hot spare system Video Input and Transmission, Connectable to the third-party network cameras Compression and Recording, H.265+ compression effectively reduces the storage space by upto 75%, Full channel recording at up to 12MP resolution HD Video Output HDMI1 / VGA1 outputs provided HDMI1 Video output at up to 4K ( 3840 × 2160 ) resolution Storage and Playback, Upto 16 SATA interfaces and 1 eSATA interface For HDD connection, Support upto 10TB capacity For each HDD, Smart search For efficient playback. and smart playback to improve the playback efficiency, Supports VCA search For fire/ship/temperature /temperature difference detection triggered video files, POS inFormation overlay on live view and playback, POS triggered recording and alarm Network & Ethernet Access Hik-Connect For easy network management, 2 Gigabit Ethernet network interfaces 200 Supply ,Testing and Commissioning of 4MP Infra Red Dom Camera and fixing the same on wall/ceiling including providing necessary connections etc. complete as required 201 Supply of 8MP, Internet Protocol fixed BULLET CAMERA with following specification:●1/2.5 Progressive Scan CMOS, ● 3840 × 2160 @15 fps,2.8/4 mm fixed lens,01 lux @ (F1.2, AGC ON), 0.028 lux @(F2.0, AGC ON), 0 lux with IR, H.265+, H.265, H.264+, H.264, 2 Behaviour analyses ( Line crossing detection, intrusion detection)● Face Detection ● 120dB WDR, ● BLC/3D DNR/ROI, IP67 complied●On-board Storage -Built-in micro SD/SDHC/SDXC card slot, up to 128 GB,● Shutter Speed 1/3 s to 1/100,000 s, ● 3-Axis Adjustment Pan: 0° to 360°, tilt: 0° to 100°, ● rotate: 0° to 360°, 2.8 mm, ● horizontal FOV: 102°, vertical FOV: 53°, diagonal FOV: 124°, ●Lens Mount M12 ● IR Range I5: up to 50 m, ● Image Settings Rotate mode, saturation, brightness, contrast, sharpness adjustable by client software or web browser, ● Power Consumption and Current-12 VDC, 0.7 A, max. 7.5W PoE: (802.3af, 36V to 57V), 0.3 A to 0.2 A, max. 9W● Camera out fitted with metal housing so as to prevent the lens from damages during physical abuse 202 Supply, Installation, Testing and Commissioning of 55 smart LED TV with following specifications a) Full HD 1920 x1080 (4K monitor) b) IPS panel c) Slim back light LED module d) 900 PMI e) Triple XD engine f) Dynamic scanning g) ANRh) True colour generatori) 8modes of picture j) picture wizardIII k) Real cinema 24P l) HDMI -3Each m) USB -3Each n) Built in LAN o) Magic remotep) Dimension 1242 x 724 x 55.1min(37) 203 Supply, laying and termination of high quality Un- Armoured Optical Fiber (48 Fibers) along with the all accessories connectors, switches etc complete as required 204 Supply, fixing and termination of high quality rack mounted type patch panel with one number of 24 port switch, fixing frames, links and interconnections, necessary accessories etc., all complete as per specifications, drawings and / or as directed by the Engineer 205 Supply, fixing and termination of high quality floor mounted type 24U floor mountable powder coated Rack with 3x5A Power Manager, 1 position fan, min 1 nos of shelf, Front Glass double door with Lock & key with suitable network port switch, fixing frames, links and interconnections, necessary accessories etc., all complete as per specifications, drawings and / or as directed by the Engineer in charge 206 Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with followingcomponents complete as required:-a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modulesused in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years.b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust thevoltage and frequency level to suit the Grid Voltage Frequency.c) Data Monitoring System complete with accessories.d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugsand other accessories etc. as required.e) Lightning and surge voltage protection.f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required. 207 Supply, Erection, Testing and Commissioning of new 160 kVA, 11kV/433V, 3-Phase, 50 Hz, ONAN Cooled, Copper wound Transformer with Energy Efficient level-I, Dyn11 vector group, first fill of oil, Bushing on HT side & Cable box on LT side, off circuit tappings of +5% to -10% in steps of 2.5% with standard fittings confirming to IS 1180, including transportation of the machine from OEM factory to site, mechanized mounting of transformer in the DT structure, providing necessary cable end terminations (LV side), connection of 4 SWG copper down conductor (HV side), body and neutral earth connections, insulation resistance testing and certification of the same etc. as required 208 Providing new service connection to the Divisional Office building by preparation of drawings, coordinating with EB, deposit amount/ statutory charges to be paid to EB for supply and fixing of poles/DT structures, overhead ACSR conductors, associated accessories, including any additional works as per the instruction of EB/FCI engineer-incharge etc. as required. (Deposit Amount/Statutory Fees will be paid by FCI as per actual only) 209 Supplying and drawing of Multicore Round PVC insulated and FR PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volts, conForming to IS: 694in the existing surface/ recessed steel/ PVC conduit as required.3 x 1.5 sq. mm 210 Supply,erection and testing & commisioning of 2HP submersible pumpset in theOpen borewell of capacity of 4800 LPH @ 265Ft, max. total head of 280 Ft pumps fitted with bronze impellers and having delivery size of 40mm - 430V along with 3mts cable and manufactures standard control panel which is mandatory and as directed by the officer incharge. 211 Supply of 2m x 1m x 3mm thick corrugated rubber mat as required conforming to relevant ISI specification suitable for electrical application
Contract Date : Ref. Documents   |   Contract Value : Ref. Documents
Disclaimer

We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.

Tender Detail
Website https://etender.cpwd.gov.in/login.html
Quantity
MSME Exemption No
Tender Type Open Tender
Startup Exemption Click Here
Competitive Bidding NCB
Similar Tenders