TDR : 57078395
Gujarat Energy Transmission Corporation Limited

Tender Brief :

Bharuch, Gujarat

Tender For Work of erection of 66KV equipment, Structures, Control wiring, Yard Lighting, Control-Room, Staff-Quarter Electrification Supply of Furniture CCTV Camera etc at 66Kv Soliya S/S under construction Division Bharuch

Published: 18 Aug 2026
Opening: Ref Document
Closing: 08 Sep 2026
Amount: 40.07 Lakhs
EMD: 40071
Tender Fee: 1180


Works Access Control Systems Air Rifles Airport Signaling Systems Alarm Systems Alcohol analyzer
14
Days Left
Tender Summary / Eligibility Criteria
Work of erection of 66KV equipment, Structures, Control wiring, Yard Lighting, Control-Room, Staff-Quarter Electrification Supply of Furniture CCTV Camera etc at 66Kv Soliya S/S under construction Division Bharuch
Documents Download All
6ff0cc6dab52477784b6d39f098a9fc6
6ff0cc6dab52477784b6d39f098a9fc6.html
TendarDocument
TendarDocument.pdf
No Boq
No Corrigendum
Probable Bidders

AI engine predicts probable bidders to help you bid strategically.

MSME Exception
Explore More →
Technical
Tender involves procurement of high capacity electrical equipment including diaphragm coupling of pump & motor with 90kW capacity at 2900 RPM. The project scope includes installation, testing, commissioning and operational handover.
Previous / Similar Result
BRR : 9057692 Tender For Creation Of 66 Kv Ais Substation Jaindapur - 12.5 / 16Mva, 66 / 11Kv T / Fs ( To Be Provided By Hvpnl ) 2 Time Synchronizationequipment 3 66 Kv Sf-6 Breaker Along With 20% Extra Sf-6 Gas 4 66 Kv Isolator With E / Switch 5 66 Kv Isolator Without E / Switch 6 66 Kv Surge Arrestor 7 66 Kv Cts For Line & Bus Coupler ( 600-300-150 / 1-1-1A ) 8 66 Kv T / F Ct ( 300-200-150 / 0.577-1-1A ) 9 66 Kv Pt 10 66 Kv Nct ( 300-200-150 / 1A ) 11 11 Kv Nct ( 1200-900 / 5A ) 12 11 Kv La 13 11 Kv 13 Panel Board ( 1250A ) With One Sem On Each T / F I / C Panel ( Including One No. Bus Sectionalizer Panel ) 14 66Kv C&R Panels A ) Bus Coupler Protection And Circuit Breaker Panel ( Without Auto Reclose ) With Sas 15 B ) Line Protection And Circuit Breaker Panel ( Without Auto Reclose ) With Sas 16 C ) Transformer Protection And Circuit Breaker Panel ( Without Auto Reclose ) With Sas 17 4800Kvar 12.65Kv Automatically Switched Capacitor Bank Along With Allied Equipment ( Controlledby One Vcb ) 18 220V 100Ah Battery ( Vrla ) 19 220 V 100 Ah Battery Charger 20 220 V 100 Ah D.C.D.B. 21 415 V Lt Ac Distribution Board 300 A 22 11 / 0.4 Kv Station T / F 200 Kva 23 ( A ) 1.1 Kv Copper Control Cable Unarmoured For 66Kv Bays Of Size 7Cx4mm2, 4Cx4mm2, 2Cx4mm2, 2Cx6mm2, 3Cx2.5Mm2, 16Cx2.5Mm2, 10Cx2.5Mm2 & 7Cx2.5Mm2 Including Junction Box Etc. Refer Section-6 Of Copper & Control Cable & Section-7 For Switchyard Erection. 24 ( B ) Stainless Steel Mk ( 200Tb ) 25 11 Kv Power Cable Xlpe 1C X1000mm2 For T / F To 11Kv Incomer With Termination Kit For Both Ends. 26 11 Kv Power Cable Xlpe3c X 185Sq Mm For Capacitor Bank With Termination Kit For Both Ends 27 11 Kv Power Cable Xlpe 3C X 50 Sq Mm For Station T / F With Termination Kit For Both Ends. 28 650 / 1100 Volts 3.5 Core 240 Mm2 Aluminium Power Cable From Aux. T / F To Acdb 29 650 / 1100 Volt 3.5 Core 70 Mm2 Aluminium Cable For Oil Filtration Set. 30 650 / 1100 Volt 4Core 16Mm2 Unarmoured With Copper Power Cable For Mldb And Other Cable Required As Per Contract For 66Kv Bays. 31 Earthing Mat Material. The Earth Mat Will Be Designed / Quoted For Soil Resistivity Of 50 ?M. In Case Soil Resistivity Is More Than 50 ?M Then The Earth Mat Will Be Designed For Actual Soil Resistivity. The Payment Of Extra Material To Be Used For Earth Mat Shall Be Made On Pro Rata Basis. The Approximate Area Of Earth Mat To Be Laid Is Given In The Corresponding Columns Of The Substations. However, Item Will Remain A Lot Item. ( 4300 Sq. Meter ) 32 Computer System:-A. Computer Sytem ( Sff ) With Intel Core I5, 9Th Generation Processor, 8 Gb Ram, 1 Tb Hdd, 19.5 Display With Ups 33 B. Mono Chrome Multi-Functional Printer, A-4, 25 Ppm, Wi-Fi 34 Fire Fighting Equipments Asper Section -6I ) 22.5 Kg Capacity Fe Co2 Type, Trolley Mounted 35 Ii ) 25 Kg Capacity Fe Dcp Type, Trolley Mounted 36 Iii ) Dcp 9 Kg Capacity, Wall Mounted 37 Iv ) Fe Co2 6.5 Kg Capacity, Wall Mounted 38 V ) Dcp 6 Kg Capacity, Wall Mounted 39 Vi ) Foam Type 9 Litre Capacity, Wall Mounted 40 Vii ) Water Co2 9 Litre, Wall Mounted 41 Viii ) Fire Buckets ( 12 Nos. With Stand In One Set ) 42 Complete Lighting Of Control Room Building , Switch Yard Area, Road And Street As Per Section -7 Of The Specification.A ) Supply And Installation Of 2 Fittings Of 240W Led Lamps With All Accessories For Complete Lighting Of Outdoor Switch Yard Area As Per Clause 16.0 Of Section 7 Of The Specifications. 43 B ) Supply And Installation Of 35W Led Tube On Tubular Steel Poles Along With The Boundary Wall At A Distance Of 30 Meter As Per Clause 16.0 Of Section 7 Of The Specification 44 C ) Complete Lighting Of Road And Street By Providing 90W Led Lamps On Tubular Steel Poles At A Distance Of 15Meter Along The Roads And Streets As Per Clause 16.0 Of Section 7 Of The Specification. 45 D ) Supply And Installation Of Post Top Lantern 40W Led Lamps With All Complete Accessories At The Entrance Gate Of Sub-Station. 46 E ) Supply And Installation Of 40W Led Lamps With All Complete Accessories On Corners Of Control Room Building. 47 Complete Substation Automation System Of 66 / 11Kv Substations Including Hardware ( Along With Transducers ) For 8 No. 66Kv Present Bays And Software ( For 5 No. Present Bays As Well As 3 No. Future Bays ) Along With Associated Equipment For The Bays ( Bay As Defined In The Technical Specification, Sec-Sub-Station Automation System ) As Per Technical Specificationnote: Signals From Protection Relays In 11Kv Incomer Would Also Be Wired To Substation Automation System ( Sas ) 48 High Wall Type Split Ac Unit Of 2 Ton Capacity For Scada Room ( As Per Technical Specification ) 49 High Wall Type Split Ac Unit Of 2 Ton Capacity For C&R Panels In Electrical Room. 50 High Wall Type Split Ac Unit Of 2 Ton Capacity For Battery Room. 51 Bolted Type 11Kv Single Tension String Assembly With 3 Numbers Anti Fog Type Disc Insulators ( E&M Strength 9000 Kg ) Per String With All Hardware Accessories Including Ball & Socket Connections And Tension Clamp Sets Suitable For Twin Zebra Conductor. Alternatively The Bidder May Quote Silicon Polymer Composite Insulator String In Place Of Disc Insulators . 52 66 Kv Bolted Type Single Tension String Assembly With 6 Numbers Anti Fog Type Disc Insulators ( E&M Strength 9000 Kg ) Per String With All Hardware Accessories Including Ball & Socket Connection And Tension Clamp Set Suitable For Single Zebra Conductor. Alternatively The Bidder May Quote Silicon Polymer Composite Insulator String In Place Of Disc Insulators. 53 66 Kv Bolted Type Single Suspension String Assembly With 5 Numbers Anti Fog Type Disc Insulators ( E&M Strength 9000 Kg ) Per String With All Hardware Accessories Including Ball & Socket Connections And Suspension Clamp Set Suitable For Single Zebra Conductor. Alternatively The Bidder May Quote Silicon Polymer Composite Insulator String In Place Of Disc Insulators. 54 Boltless C-Type Wedge Connectors Matching With Conductor Size. 55 Copper Lugs Glands, Pvc Ferrules For Control Cabling. 56 Fibrecleats, Aluminium Clamps, Bolts, Nuts, Washers Etc., For Fixing Control Cables In Trenches. 57 Galvanized Iron Perforated Tray With Side Coupler Plate Bolts, Nuts, Washers And Clamps Etc. Of Size 75X25x2 Mm, 150X25x2mm, 100X25x2mm Etc. & G.I. Conduits Of 50Mm / 100Mm Dia From Equipment To Main Trench As Per Section-7, Switchyard Erection. 58 Acsr Zebra Conductor 59 Aac Tarantulla Condoctor 60 7 / 3.15 Gs Earthwire 61 Spacers For Twin Zebraconductor 62 U-Bolt 20Mm Dia 63 Mandatory Spares For Hardware / Mechanical / Electrical Auxiliaries To Be Supplied. 10 % Of The Finally Approved Quantities For Item Mentioned From Sr. No. 51 To 53. 64 Item For Associated Structure Work‘Lattice Type Steel Structure For 66Kv Ais S / Stn. Jaindapur. Supply Of Material, Preparation Of Fabrication Drawing, Galvanizing And Delivery Of Lattice Type Steel Structure For Tower And Beams For 66 / 11Kv Switchyard Fabricated From Steel Conforming To Is:2062 Including Nuts-Bolts Gusset Plates Foundation Bolts And Other Accessories As Per Drawings Supplied By The Owner.A ) . Main S / Stn. Tower And Beama ) Tower Type Ct-4 65 B ) Tower Type Ct-5 66 C ) Tower Type Ct-6 67 D ) Tower Type Ct-8 68 E ) Beam Type Cb-6 69 F ) Beam Type Cb-7 70 G ) Tower Type Dt-2 71 H ) Tower Type Dt-3 72 I ) Beam Type Db-2X 73 B. Equipment Structurea ) 66 Kv Ct Drg. No. Htd / St-88R 74 B ) 66 Kv Nct Drg. No.Htd / St-145 ( If Required ) 75 C ) 66 Kv Pt Drg. No. Hhw / St-66 76 D ) 66 Kv Surge Arrestor Drg. No. Htd / St-89 77 E ) 66 Kv Isolator Drg. No. Htd / St-87R 78 F ) 66 Kv L&E Switch Drg. Htd / St-87R 79 G ) 11 Kv Nct Drg. Htd / St-149 ( If Combined Structure Used ) 80 H ) 11 Kv Nct Drg. Htd / St-88R ( If Required ) 81 1. Earth Work 1.1. Earth Filling With Good Earth ( As Per Satisfaction Of Executive Engineer / Civil Works Division ) , Laying In Layers ( As Per Specification ) , Dressing, Including Carriage, Irrespective Of Lead, Loading, Unloading, Watering And Compaction In Layers With Roller Including Compensation Of Earth Complete In All Respect. 82 Foundationssupply Of Labour, T&P, Material And Construction Of Rcc Footings & Pedestals Etc. For Steel Gantry And Equipment Structures Complete In All Respects As Per Technical Specifications & Drawings Attached With The Tender Document Including Cost Of Excavation, Concreting, Cement, Reinforcement Steel, Form Work, Grouting, Holding Down Bolts, Backfilling Etc.And Other Items Not Mentioned Herein But Required For The Completion Of Work.A. Gantry Towers 66Kv Sidei ) Ct-4 83 Ii ) Ct-5 84 Iii ) Ct-6 85 Iv ) Ct-8 86 33Kv Sidei ) Dt-2 87 Ii ) Dt-3 88 B. Equipment 66Kv Sidei ) 66Kv La 89 Ii ) 66Kv Cvt 90 Iii ) 66Kv Nct 91 Iv ) 66Kv Ct 92 V ) 66Kv L&E & Isolator 93 11Kv Sidei ) 11Kv Nct 94 3. Breaker Foundationdesign, Engineering, Supply Of Labour, Material, Equipment & Const. Of Foundations For 66Kv Sf-6 Circuit Breaker Including All Associated Works Pcc, Rcc, Structural Steel, Steel Reinforcement & Any Other Item Not Specifically Mentioned Herein But Reqd. For Completion Of Work As Per Tech. Spec.66 Kv Breaker Foundation 95 4. Capacitor Bank Foundationsdesign, Engg. & Supply Of Labour, Material & Construction Of Foundations For Following Rating Capacitor Bank With Capacitor Unit ( With Allied Equipments ) & Series Reactor Etc. Including Chain Link Fencing 1.8M Height Around Cap. Bank Complete In All Respect Including Any Other Items Not Specifically Mentioned Herein But Required For Completion Of Job As Per Technical Specification.4800Kvar 11Kv Capacitor Bank 96 5. Transformer Foundation5.1 Design, Engg., Supply Of Labour, Material And Construction Of T / F Foundation Including Radiator Foundations Etc. Complete Transformer Foundations Including All Associated Works, Rcc, Pcc, Reinforcement Steel, Misc. Structural Steel And Other Items Not Mentioned Herein But Required For The Completion Of Work As Per Technical Specifications And Hvpnl Drawing. In Case Additional Foundation Is / Are Required As Per Approved Equipment Drawing, The Same Shall Be Constructed By The Successful Bidder Without Any Extra Cost To Hvpnl. Such Drawing ( S ) Shall, However, Be Got Approved From Hvpnl.11 / 0.4Kv 200Kva Station T / F 97 5.2 Construction Of Transformer Foundation Including All Associated Works, Rcc, Pcc, Reinforcement Steel, Misc. Structural Steel And Other Items Not Mentioned Herein But Required For Completion Of Work As Per Technical Specifications & Drawing Attached. In Case Extra Foundation ( S ) Has / Have To Be Constructed ( As Per Approved T / F Drawing ) To Complete The Job, Nothing Extra Would Be Paid On This Count.I. 12.5 / 16 Mva 66 / 11 Kv T / F Foundation 98 6. Cable Trenchessupply Of Labour, Material Such As Cement, Reinforcement Steel, Gi Angles, Flats, Pcc & Brick Pillars Below Cable Trenches For Construction Of Out-Door Cable Trenches ( Odct ) Of Required Depth / Type With Pre-Cast Rcc Covers Including Associated Works Like Cable Trench Culverts Crossings For Roads And Sump- Pit-Cum-Pump Chamber With 2Hp Motor Of Reputed Make, Starter, Volt Meter, Amp-Meter Etc. As Per Approved Trench Layout Plan, Hvpnl Drgs. & Tech. Specs. Complete In All Respect. 99 7.Site Surfacing7.1Providing, Supplying And Laying 100Mm Thick Pcc ( 1:4:8 ) Using 20Mm Nominal Coarse Aggregates And Spreading 100Mm Thick Layer Of 40Mm Nominal Size Uncrushed / Crushed / Broken Stone Pebbles Over The Pcc Including Construction Of Toe Wall ( Exposed Wall Plastered With Cement Mortar 1:5 ) To Hold 40Mm Single Size Uncrushed / Crushed / Broken Stone Pebbles Wherever Required In The Bays Covered Under The Present Scope As Detailed In The Gelo & Instructions Of Concerned Executive Engineer / Civil Works Division. 100 7.2 Providing, Supplying & Laying Two Layers Of Uncrushed / Crushed / Broken Stone / Pebbles Gravel Fill. The First Layer After Compaction Shall Make Min. 50Mm Thickness Course / Layer Of 40Mm Nominal Size, Including Dressing, Rolling & Compaction Complete As Per Specs., Gelo And Instructions Of Xen / Cwd. 101 8. Roads & Pcc Pavement8.1Supply Of Labour, Material And Construction Of Cement Concrete Roads And Walkways / Shoulders From Nh / Sh / Etc. To Switch Yard / Switch House Building As Per Gelo / Clo As Per Sectional Detail Drawing No. Hcd / Sk-181 R1 And Technical Specification.I. 6.0M Wide 102 Ii. 3.66M Wide 103 Iii. Pcc In Front And Rear Of Parking Area Of Sh Building As Per Tech. Specification And Drawing Hcd / Sk-172. 104 9.Road Culvertsdesign, Engineering And Const. Of Pipe Culvert ( S ) At Suitable Locations Under The Approach Road ( From Main Pwd / Huda / Municipal / Village Road To The Sub-Station Entry Point ) Including, Cost Of Labour, Material Complete In All Respects As Per I.R.C. Standards. 105 10. Boundary Wall10.1 Supply Of Labour, Material And Construction Of Front, C & U / C Boundary Walls Including Main Gate Foundations As Per Gelo / Clo, Technical Specifications. & Hvpnl Drg. Hcd / Ts-1176 R1 Including Excavation Backfilling, Lean & Dpc Complete In All Respect.I. 6 Ft. High With Gi Barbed Wire On Angles At Top. 106 Ii. 4½ Ft. High Front Wall With Grill At Top. 107 Iii. 4½ Ft. Side Wall With Gi Barbed Wire 108 10.2 Supply Of Labour, T&P, Material And Construction Of Front, Side & U / C Boundary Walls Including Main Gate ( S ) ( Brickwork Below Dpc Level ) As Per Gelo / Clo, Tech. Spec. & Hvpnl Drawings Complete In All Respects. 109 11. U / C Fencing & Gatesproviding & Fixing Chain Link Fencing Including Foundations, Gi Angle Iron Posts And Gate ( S ) Complete As Per Electrical Layout & Tech. Spec. & As Per Drawing Attached. 110 12. Drainage–Cum-Rain Harvesting System12.1Supply Of Labour, Material For Construction Of 1 No. Recharge Structure With Bore Well As Per Hvpn Drawings & Specs. Complete In All Respect. The Location Of Recharge Structure Shall Preferably Be Located On Corner ( S ) Of The Substation And Shall Be Got Decided From The Concerned Xen / Civil Works Division On The Basis Of Surroundings Of The Substation ( S ) . In Case Ground Water Table Is Less Than 8M From Fgl, Rain Harvesting Well Shall Not Be Constructed ( The Drainage System With Sump Pit Is To Be Constructed As Per Item Mentioned Below ) . 111 12.2 The Successful Bidder Shall Evolve Design & Drawing For Drain, Manholes With Rcc Covers Andsettlement Tankincluding Preparation Of Drainage Layout Drawing For Disposal Of Rain Water From Building’S Roof Top & Switch Yard ( S / Stn. ) Area Into Bore Well In Such A Way That There Shall Be No Ponding Of Water On The Roof And Switch Yard ( S / Stn. ) . The Layout So Developed Shall Be Got Approved From The Employer. The Location Of Sump-Pit-Cum-Pump Chamber Shall Preferably Be Located On Corner ( S ) Of The S / Stn. And Shall Be Got Decided From The Concerned Xen / Civil Works Division On The Basis Of Surroundings Of The Substation ( S ) . The Successful Bidder Will Also Supply Labour And Material For Construction Of 1 No.Sump-Pit-Cum-Pump Chamber As Per Hvpnl Drgs. & Provide One No. Non Clog Pump ( S ) Of 5Hp Of Reputed Make Capacity With Main Switch, Starter, Volt Meter, Amp. Mtr. Etc. ( For Each Sump Pit ) For Disposal Of Excess Water To Outfall Point. Any Other Item ( S ) Not Mentioned Herein But Is / Are Required For Completion Of Works Shall Be Done By The Successful Bidder Without Any Extra Cost To The Employer. 112 13. Control Room Buildingsupply Of Labour, Material & Construction Of Control Room Building Complete In All Respect As Per Tech. Specs. & Approved Drgs. Attached Including Exterior & Interior Acrylic Emulsion Paint, All Internal Services Like Water Supply Including Supply & Providing Of 5000Ltr. Capacity Triple Layered Sintex / Diplast Pvc Tank, Sewerage System, Staircase, Electrification Including Wiring, Modular Switches, Maximum 20W 4Ft. Long Led Tubes With Fittings Minimum 1960 Lumens, Ceiling / Exhaust Fans & 4 No. 2T Split Acs, Finishing, Plinth Protection, Indoor Trenches, Trench Covers, Soakage Pit Near The Switch House Building, Connection Of Sewerage System To Soakage Pit / Sewerage System Of Local Authorities ( As Applicable ) , Connection To Main Water Supply System Of Local Authority / Submersible Bore ( As Applicable ) Etc. & Any Other Item Not Mentioned Herein But Reqd. For Completion Of Works. The Successful Bidder Shall Also Provide Water Supply Connection From Bore Well / Huda / Municipal / Public Health Or Panchyat Water Supply Scheme ( As Per Available Source Of Portable Water ) To The Control Room Bldgs. Without Any Extra Cost Of Hvpnl. 113 14. Rcc M-20 Inclusive Of Labour, Material, Shuttering, Steel Reinforcement Etc. Complete In All Respects To Compensate Excess Quantity Required To Be Executed Due To Difference In Existing Ground Level And The Formation Level To Be Fixed After Contouring Or Difference On Account Of Revised Drg Issued At The Time Of Construction And The Tender Drg. 114 15. Barbed Wire With Rcc Postsupply Of Labour, T&P And Material For Providing Barbed Wire Fencing With Rcc Post Including Gates Etc. Complete In All Respect As Per Clo, Technical Specification And Attached Drawings.
Contract Date : Ref. Documents   |   Contract Value : Ref. Documents
BRR : 9231079 Tender For 66 Kv Substation Sullar; 1 25/31.5 MVA, 66/11kV T/Fs 2 66 kV SF-6 Breaker along with 20% extra SF-6 Gas 3 66 kV Isolator with E/Switch 4 66 kV Isolator without E/Switch 5 66 kV Surge Arrestor 6 66 kV CTs for Line & Bus Coupler (600-300-150/1-1-1A) 7 66 kV CT for T/F (300-200-150/0.577-1-1A) 8 66 kV PT for line 9 66 kV NCT (300-200-150/1A) 10 11 kV NCT (1800-900/5A) 11 11 kV Surge Arrestor 12 11 kV 15 Panel Board (2000A)(including one no. bus sectionalizer panel) 13 66kV C&R Panels with SAS:a) Bus Coupler Protection and Circuit Breaker Panel (Without Auto Reclose) with SAS 14 b) Line Protection and Circuit Breaker Panel (Without Auto Reclose) with SAS with line current differential- cum- distance protection relay 15 c) Transformer Protection and Circuit Breaker Panel (Without Auto Reclose) with SAS 16 9000 KVAR 12.65 kV Automatically Switched Capacitor Bank along with allied equipment as per technical specification 17 220V 100AH Battery San Tubular 18 220 V 20/30 A Battery charger (SMPS) 19 220V D.C.D.B. 20 415 V LT AC Distribution Board 300 A 21 11/0.4 kV Station T/F 200 KVA 22 (a) 1.1 kV Copper Control Cable unarmoured for 66kV bays of size 7Cx4mm2, 4Cx4mm2, 2Cx4mm2,2Cx6mm2, 3Cx2.5mm2, 16Cx2.5mm2, 10Cx2.5mm2 & 7Cx2.5mm2 including junction box etc. refer Section-5 of copper & control cable & Section-7 for switchyard erection. 23 (b) Stainless steel MK (200 TB) 24 11 kV Power Cable XLPE 1C x1000mm2 for T/F to 11kV incomer (4 run per phase for each transformer allocating them 2 runs per phase for each 11kV I/C). 25 Termination kit at both ends for 11 kV XLPE Power Cable(1C x1000 mm2 ) Termination kits for (indoor/outdoor) both ends alongwith assessories constitute a set of each cable. 26 11 kV Power Cable XLPE3C x 400sq mm for Capacitor Bank 27 Termination kit at both ends for 11 kV XLPE Power Cable( 3C x 400 mm2) Termination kits for (indoor/outdoor) both ends alongwith assessories constitute a set of each cable. 28 11 kV Power Cable XLPE 3C x 50 sq mm for station T/F 29 Termination kit at both ends for 11 kV XLPE Power Cable( 3C x 50 mm2) Termination kits for (indoor/outdoor) both ends alongwith assessories constitute a set of each cable. 30 650/1100 Volts 3.5 core 240 mm2 aluminium power cable from Aux. T/F to ACDB. 31 650/1100 Volt 3.5 core 70 mm2 aluminium cable for oil filtration set. 32 650/1100 Volt 4core 16mm2 unarmoured with copper power cable for MLDB and other cable required as per contract for 66 kV bays. 33 Earthing Mat Material. The earth mat will be designed/ quoted for soil resistivity of 50Ωm. In case soil resistivity is more than 50Ωm then the earth mat will be designed for actual soil resistivity. The payment of extra material to be used for earth mat shall be made on pro rata basis. The approximate area of earth mat to be laid is given in the corresponding columns of the substations. However, item will remain a Lot item. (calculations may be made considering fault/shock duration of 1 sec., 5400 m2) 34 Fire Fighting equipments as per section-6:i) 22.5 Kg Capacity FE CO2 type, Trolley Mounted 35 ii) 25 Kg Capacity FE DCP type, Trolley Mounted 36 iii) DCP 10 Kg Capacity, Wall mounted 37 iv) FE CO2 6.5 Kg Capacity, Wall mounted 38 v) DCP 5 Kg Capacity, Wall mounted 39 vi) Foam Type 9 Litre Capacity, Wall mounted 40 vii) Water CO2 9 Litre, Wall mounted 41 viii) Fire Buckets (12 Nos. with stand in one set) 42 Complete lightning of control room building, switch yard area, road and street as per section-7 of the specification:a) Supply and installation of 2 fittings of 240W LED lamps with all accessories for Complete lighting of outdoor Switch yard area as per clause 16.0 of section 7 of the specifications. 43 b) Supply and installation of 35W LED tube on tubular steel poles along with the boundary wall at a distance of 30 meter as per as per clause 16.0 of section 7 of the specification 44 c) Complete lighting of road and street by providing 90W LED lamps on tubular steel poles at a distance of 15meter along the roads and streets as per as per clause 16.0 of section 7 of the specification. 45 d) Supply and installation of post top lantern 40W LED Lamps with all complete accessories at the entrance gate of sub-station. 46 e) Supply and installation of 40W LED Lamps with all complete accessories on corners of control room building. 47 Complete Substation automation system of 66/11kV substation including hardware (along with transducers) and software along with associated equipment for the bays (bay as defined in the technical specification, sec-sub-station automation system) as per technical specification. Name of 66 kV BayPresent Future66 kV T/F Bay2 66 kV Line Bay 46*66 kV Bus Coupler Bay 1 * Provision shall be made in SAS to accomodate future scope (i.e. 6 No. 66 kV bays as per space available in GELO) alongwith present scope.Note: Signals from protection relays in 11 kV incomer would also be wired to substation automation system (SAS) 48 Time synchronization equipment 49 High wall type split AC unit2 Ton capacity for C&R Panel room and SCADA room: (as per technical specification). 50 Computer system (SFF) with: Intel core i5 processor with 11th generation or higher as specified in sectiion-04 51 Multi-Function Monochromatic Laser Jet Machine (A4-25 PPM or more) with print copy and scan function, Duplexing feature, composite cartridge, ADF, A4 or larger flatbed size, Networking and wi-fi both, at least 1 input tray, 3 years on site OEM warranty. 52 BOM FOR SAMAST COMPLIANT IEM (ON SEPARATE CUBICLE) FOR 11KV I/C: 1. (a) 3P4W Interface Energy Meters (ABT type) 0.2s Class 1A with TTB & BCS 53 1 (b) Testing of IEM System from NABL accredited lab 54 2. Wired Indoor Meters Panel suitable for 8 meters 55 3. 16 P Industrial Grade un-managed Network switch 56 4. (a) Data concentrator unit (DCU)/ communication Gateway (IG) with dual SIM Modem along with enclosure and accessories 57 4. (b) 3C x 2.5 Sq. mm Un-armoured cable for DCU and Switches 58 5. Cat-6 cable-unshielded 59 6. PVC conduit Pipe - 3/4 with accessories for Cat-6 cable 60 7. Armored Fibre Optic Cable (2 pair) 61 8. HDPE conduit - 40/33 with accessories 62 9. 4Cx4 Sqmm armoured cable for PT 63 10. 4Cx4 Sqmm armoured cable for CT 64 48V 120AH Battery Bank San Tubular 65 48V SMPS Battery Charger (for 48V 120AH Battery Bank San Tubular Battery) 66 For 66kV Substation HVPNL Chaurmastpur 1. The supply of Numerical Line Current Differential-cum- Back up Distance Protection Relay in place of existing Distance Protection Relay on the existing C&R panels (non-SAS compliant) installed at 66kV S/stn. HVPNL, Chaurmastpur (for 66 kV D/C Chaurmastpur - Sullar Lines)2. The erection/ retrofitting, testing & commissioning of Numerical Line Current Differential-cum- Back up Distance Protection Relay in place of existing Distance Protection Relay on the existing C&R panels (non-SAS compliant) above at sr. no. 40 (1) installed at 66kV S/stn. HVPNL, Chaurmastpur shall be the part of scope of successful bidder. 67 For 66kV Substation HVPNL Layalpur Basti 1. The supply of Numerical Line Current Differential-cum- Back up Distance Protection Relay in place of existing Distance Protection Relay on the existing C&R panels (non-SAS compliant) installed at 66kV S/stn. HVPNL, Layalpur Basti (for 66 kV D/C Layalpur Basti – Sullar Lines).2. The erection/ retrofitting, testing & commissioning of Numerical Line Current Differential-cum- Back up Distance Protection Relay in place of existing Distance Protection Relay on the existing C&R panels (non-SAS compliant) above at sr. no. 41 (1) installed at 66kV S/stn. HVPNL, Layalpur Basti (for 66 kV D/C Layalpur Basti – Sullar Lines) shall be the part of scope of successful bidder. 68 Bolted type 11kV tension string assembly with 3 numbers Anti FOG type disc insulators (E&M strength 9000 kg) per string with all hardware accessories including ball & socket connections and tension clamp sets suitable for twin tarantulla conductor. Alternatively the bidder may quote silicon polymer composite insulator string in place of Disc Insulators 69 66 kV Bolted type tension string assembly with 6 numbers Anti FOG type disc insulators (E&M strength 9000 kg) per string with all hardware accessories including ball & socket connection and tension clamp set suitable for single zebra conductor. Alternatively the bidder may quote silicon polymer composite insulator string in place of Disc Insulators 70 66 kV bolted type tension string assembly with 6 numbers Anti FOG type disc insulators (E&M strength 9000 kg) per string with all hardware accessories including ball & socket connections and suspension clamp set suitable for Twin zebra conductor. Alternatively the bidder may quote silicon polymer composite insulator string in place of Disc Insulators 71 66 kV bolted type suspension string assembly with 5 numbers Anti FOG type disc insulators (E&M strength 9000 kg) per string with all hardware accessories including ball & socket connections and suspension clamp set suitable for Singlezebra conductor. Alternatively the bidder may quote silicon polymer composite insulator string in place of Disc Insulators 72 66 kV bolted type suspension string assembly with 5 numbers Anti FOG type disc insulators (E&M strength 9000 kg) per string with all hardware accessories including ball & socket connections and suspension clamp set suitable for Twin zebra conductor. Alternatively the bidder may quote silicon polymer composite insulator string in place of Disc Insulators 73 Boltless C-Type Wedge connectors matching with conductor size. 74 Copper lugs glands, PVC ferrules for control cabling. 75 Fiber cleats, Aluminium clamps, bolts, nuts, washers etc., for fixing control cables in trenches. 76 Galvanized iron perforated tray with side coupler plate bolts, nuts, washers and clamps etc. of size 75x25x2 mm, 150x25x2mm, 100x25x2mm etc. & G.I. Conduits of 50mm/100mm dia from equipment to main trench as per Section-7, Switchyard erection. 77 ACSR Zebra Conductor 78 AAC Tarantulla Conductor 79 7/3.15 GS Earth wire 80 Spacers for Twin Tarantullaand Twin Zebra Conductor 81 U-bolt 20mm dia. 82 Mandatory spares for hardware/mechanical/Electrical auxiliaries to be supplied. 10 % of the finally approved quantities for item mentioned from Sr. No. 68 to 72. 83 2.5 ″ dia HDD/PVC pipe for 4c x 4 mm2 c/cable from CT, VT to maintaining system as per sec-5. 84 Item for associated structure workA)‘Lattice type steel structure for 66 kV AIS Sullar. Supply of material, preparation of fabrication drawing, galvanizing and delivery of lattice type steel structure for tower and beams for 66/11KV switchyard fabricated from steel conforming to IS: 2062 including nuts-bolts gusset plates foundation bolts and other accessories as per drawings supplied by the owner:Main S/Stn. tower and beam:a)Tower type CT-4 85 b) Tower type CT-5 86 c) Tower type CT-6 87 d) Tower type CT-8 88 e) Beam type CB-6 89 f) Beam type CB-7 90 g) Tower type DT-2 91 h) Tower type DT-3 92 i) Beam type DB-2X 93 B) Equipment Structure:a) 66 kV CT Drg. No. HTD/ST-88R 94 b) 66 kV NCT Drg. No. HTD/ST-145 (if required ) 95 c) 66 kV PT Drg. No. HHW/ST-66 96 d) 66 kV Surge Arrestor Drg. No. HTD/ST-89 97 e) 66 kV Isolator Drg. No. HTD/ST-87R 98 f) 66 kV L&E Switch Drg. HTD/ST-87R 99 g) 11 kV NCT Drg. HTD/ST-149 (if combined structure used) or 11 kV NCT Drg. HTD/ST-88R (if required). 100 EARTH WORK :Earth filling with good earth (as per satisfaction of Executive Engineer/Civil Works Division), laying in layers (as per specification), dressing, including carriage, irrespective of lead, loading, unloading, watering and compaction in layers with roller including compensation of earth complete in all respect. 101 2. FOUNDATIONS:Supply of labour, T&P, material and construction of RCC footings & pedestals etc. for steel gantry and equipment structures complete in all respects as per technical specifications & approved drawings including cost of excavation, concreting, cement, reinforcement steel, form work, grouting, holding down bolts, backfilling etc.and other items not mentioned herein but required for the completion of work.A. GANTRY TOWERS66kV sidei) CT-4 102 ii) CT-5 103 iii) CT-6 104 iv) CT-8 105 33kV sidei) DT-2 106 ii) DT-3 107 B. EQUIPMENT 66kV sidei) 66KV LA 108 ii) 66KV CVT/PT 109 iii) 66KV NCT 110 iv) 66kV CT 111 v) 66kV L&E & Isolator 112 11kV sidei) 11kV NCT 113 3. BREAKER FOUNDATIONDesign, engineering, supply of labour, material, equipment & const. of foundations for breaker including all associated works PCC, RCC, structural steel, steel reinforcement & any other item not specifically mentioned herein but reqd. for completion of work as per tech. spec.i) 66 kV Breaker Foundation 114 4. CAPACITOR BANK FOUNDATIONSDesign, Engg. & supply of labour, material & construction of foundations for following rating capacitor bank with capacitor unit (with allied equipments) & series Reactor etc. including chain link fencing 1.8M height around cap. bank complete in all respect including any other items not specifically mentioned herein but required for completion of job as per technical specification.i) 9000KVAR 12.65 kV Capacitor Bank 115 5. TRANSFORMER FOUNDATION5.1 Design, Engg., supply of labour, material and construction of foundation for station transformer including all associated works, RCC, PCC, Reinforcement steel, misc. structural steel and other items not mentioned herein but required for the completion of work as per technical specifications.i) 11/0.4kV 200KVA Station T/F 116 5.2 Construction of transformer foundation including all associated works, RCC, PCC, reinforcement steel, misc. structural steel and other items not mentioned herein but required for completion of work as per technical specifications & approved drgs. In case extra foundation(s) has/have to be constructed (as per approved T/F drawing) to complete the job, nothing extra would be paid on this count.i) 25/31.5 MVA 66/11 kV T/F Foundation 117 6. CABLE TRENCHESSupply of labour, material such as cement, reinforcement steel, GI angles, flats, PCC & brick pillars below cable trenches for construction of Out-Door Cable Trenches (ODCT) of required depth/ type with pre-cast RCC covers including associated works like Cable Trench Culverts,crossings for roads and sump- pit-cum-pump chamber with 2HP motor of reputed make, starter, volt meter, amp-meter etc. as per foundation & trench layout plan attached, HVPNL drgs. & tech. specs. complete in all respect. i) D-type trench 118 ii) E-type trench 119 iii) G-type trench 120 iv) H-type Trench 121 v) GI Pipe 122 vi) Sump Pit Cum Pump Chamber 123 7. SITE SURFACING7.1 Providing, supplying & laying 100mm thick PCC (1:4:8) using 20mm nominal coarse aggregates and supplying & spreading 100mm thick layer of 40mm nominal size uncrushed/ crushed/broken stone pebbles over the PCC including construction of toe wall (exposed wall plastered with cement mortar 1:5) to hold 40mm single size uncrushed/ crushed /broken stone pebbles wherever required in the bays covered under the present scope as detailed in the GELO & instructions of engineer incharge. 124 7.2 Providing, supplying & laying 100mm thick in two layers of 50mm each of 20mm nominal size uncrushed/crushed/ broken stone pebbles gravel fill including dressing, rolling & compacting complete in all respects as per specs. & instructions of engineer incharge. 125 8. ROADS & PCC PAVEMENT8.1 Supply of labour, material and construction of cement concrete roads and walkways/shoulders from NH/SH/etc. to Switch yard/Switch house building as per GELO/CLO as per sectional detail drawing no. HCD/SK-181 R1 and technical specification.i) 6.0M wide road (Near main gate of substation) 126 ii) 3.66m wide road within substation land 127 iii) PCC in front and rear of parking area of SH Building as per tech. specification and drawing HCD/SK-172. 128 9. ROAD CULVERTSDesign Engineering and construction of Pipe culvert(s) at suitable locations under the approach road (from main PWD/ HUDA/Municipal/Village road to the sub-station entry point) including, cost of labour, material complete in all respects as per I.R.C. Standards. 129 10. BOUNDARY WALL10.1 Supply of labour, material and construction of front, C & U/C boundary walls including main gate foundations as per GELO/CLO, technical specifications. & HVPNL drg. HCD/TS-1176 R3 including excavation backfilling, lean & DPC complete in all respect.i) 6 ft. high with GI barbed wire on angles at top. 130 ii) 4½ ft. high front wall including providing grill at top of wall & construction of main entrance gate (with wicket gate). 131 iii) 4½ ft. side wall with GI barbed wire 132 10.2 Supply of labour, T&P, material and construction of front, side & U/C boundary walls including main gate(s) (brickwork below DPC level) as per GELO/CLO, tech. spec. & HVPNL drawings complete in all respects. 133 11. U/C FENCING & GATESProviding & fixing chain link fencing including foundations, GI angle iron posts and gate(s) complete as per electrical layout & tech. spec. & as per drawing attached. 134 12. DRAINAGE–CUM-RAIN HARVESTING SYSTEMThe successful bidder shall evolve design & drawing for drains, manholes with RCC covers andsettlement tankincluding preparation of drainage layout drawing for disposal of rain water from building’s roof top & switch yard (s/stn.) area into respective bore well(s) in such a way that there shall be no ponding of water on the roof and switch yard (s/stn.). The layout so developed shall be got approved from the employer. The location of sump-pit-cum-pump chamber shall preferably be locatedon corner(s) of the s/stn. and shall be got decided from the concerned XEN/Civil Works Division on the basis of surroundings of the substation(s). The successful bidder will also supply labour and material for construction of sump-pit-cum-pump chamber as per HVPNL drgs. & provide one no. non clog pump(s) of 5HP of reputed make capacity with main switch, starter, volt meter, Amp. Mtr. etc. (for each sump pit) for disposal of excess water to outfall point. Any other item(s) not mentioned herein but is/are required for completion of works shall be done by the successful bidder without any extra cost to the employer.i) Drain Section-1 135 ii) Drain Section-2 136 iii) Drain Section-3 137 iv) Road Crossing 138 v) Trench Crossing 139 vi) Sump Pit Cum Pump Chamber 140 13. CONTROL ROOM BUILDINGSupply of labour, material, T&P and construction of control room building complete in all respect as per tech. specs. including exterior weather proof paint, interior emulsion, all internal services like water supply including supply & providing of 5000ltr. capacity double layer Sintex/Diplast PVC tank, Sewerage system, electrification including wiring, modular switches, maximum 20W 4ft. long LED tubes with fittings minimum 1960 lumens, ceiling/exhaust fans, Finishing, Plinth protection, RCC flooring, Indoor trenches, Soakage pit near the switch house building, connection of sewerage system to Soakage pit/Sewerage system of local authorities (as applicable), connection to main water supply system of local authority, bore (Tubewell) (as applicable) etc. & any other item not mentioned herein but required for completion of works. 141 14. RCC M-20 inclusive of labour, material, shuttering, Steel reinforcement etc. complete in all respects to compensate excess quantity required to be executed due to difference in existing ground level and the formation level to be fixed after contouring or difference on account of revised drg issued at the time of construction and the tender drg.
Contract Date : Ref. Documents   |   Contract Value : Ref. Documents
BRR : 9231097 Construction Of 66 Kv Ais Substation Mussimble, Yamuna Nagar With 2X25/31.5 Mva 66/11 Kv Power T/Fs And 66 Kv Ais Substation Sadopur, Ambala With 2 X 25/31.5 Mva 66/11 Kv T/Fs On Turnkey Basis-- 1 25/31.5 MVA 66/11 kV T/Fs 2 66 kV SF-6 Breaker along with 20% extra SF-6 Gas 3 66 kV Isolator with E/Switch 4 66 kV Isolator without E/Switch 5 66 kV Surge Arrestor 6 66 kV CTs for Line & Bus Coupler (600-300-150/1-1-1A) 7 66 kV T/F CT (300-200-150/0.577-1-1A) 8 66 kV PT for line 9 66 kV NCT (300-200-150/1A) 10 11 kV NCT (1800-900/5A) 11 11 kV LA 12 11 kV 15 Panel Board 2000A (including one no. bus sectionalizer panel) 13 66kV C&R Panels with SAS:a) Bus Coupler Protection and Circuit Breaker Panel (Without Auto Reclose)with SAS compliant 14 b) Line Protection and Circuit Breaker Panel (Without Auto Reclose) with SAS 15 c) Line Protection and Circuit Breaker Panel without Auto Reclose (SAS Compliant) with Line Current Differential-cum-Distance Protection Relay (for 66 kV D/C Dhulkote-Sadopur Lines) 16 d) Line Protection and Circuit Breaker Panel without Auto Reclose (SAS Compliant) with Distance Protection Relay (for 66 kV S/C Layalpur Basti-Sadopur Lines) 17 e) Transformer Protection and Circuit Breaker Panel (Without Auto Reclose)with SAS compliant 18 9000 KVAR 12.65 kV Automatically Switched Capacitor Bank along with allied equipments as per technical specification. 19 220V 100AH Battery San Tubular 20 220 V 20/30A Battery charger (SMPS) 21 220V D.C.D.B. 22 415 V LT AC Distribution Board 300 A 23 11/0.4 kV Station T/F 200 KVA 24 (a) 1.1 kV Copper Control Cable unarmoured for 66kV bays of size 7Cx4mm2, 4Cx4mm2, 2Cx4mm2, 2Cx6mm2, 3Cx2.5mm2, 16Cx2.5mm2, 10Cx2.5mm2 & 7Cx2.5mm2 including junction box etc. refer Section-5 of copper & control cable & Section-7 for switchyard erection 25 (b) Stainless steel MK (200 TB) 26 a) 11 kV Aluminium Power Cable XLPE 1C x1000mm2 for T/F to 11kV incomer (4 runs per phase for each transformerallocating them 2 runs per phase for each 11kV I/C) 27 b) Termination kit at both ends for 11kV XLPE power Cable (1C x 1000mm2) Termination Kits for (Indoor/Outdoor) both ends along with accessories constitute a set for each cable. 28 a) 11 kV Aluminium Power Cable XLPE 3C x 400sq mm for Capacitor Bank 29 b) Termination kit at both ends for 11kV XLPE power Cable (3C x 400mm2) Termination Kits for (Indoor/Outdoor) both ends along with accessories constitute a set for each cable. 30 a) 11 kV Aluminium Power Cable XLPE 3C x 50 sq. mm for station T/F 31 b) Termination kit at both ends for 11kV XLPE power Cable (3C x 50mm2) Termination Kits for (Indoor/Outdoor) both ends along with accessories constitute a set for each cable. 32 650/1100 Volts 3.5 core 240 mm2 aluminium power cable from Aux. T/F to ACDB. 33 650/1100 Volt 3.5 core 70 mm2 aluminium cable for oil filtration set. 34 650/1100 Volt 4core 16mm2 unarmoured with copper power cable for MLDB and other cable required as per contract for 66kV bays. 35 Earthing Mat Material. The earth mat will be designed/quoted for soil resistivity of 50Ωm. In case soil resistivity is more than 50Ωm then the earth mat will be designed for actual soil resistivity. The payment of extra material to be used for earth mat shall be made on pro rata basis. The approximate area of earth mat to be laid is given in the corresponding columns of the substations. However, item will remain a Lot item (calculations may be made considering fault/shock duration of 1 sec).(7400 sq. meter for Mussimble & 5900 sq. meter for Sadopur) 36 Fire Fighting equipments as per section-6:i) 22.5 Kg Capacity FE CO2 type, Trolley Mounted 37 ii) 25 Kg Capacity FE DCP type, Trolley Mounted 38 iii) DCP 10 Kg Capacity, Wall mounted 39 iv) FE CO2 6.5 Kg Capacity, Wall mounted 40 v) DCP 5 Kg Capacity, Wall mounted 41 vi) Foam Type 9 Litre Capacity, Wall mounted 42 vii) Water CO2 9 Litre, Wall mounted 43 viii) Fire Buckets (12 Nos. with stand in one set) 44 Complete lightning of control room building, switch yard area, road and street as per section-7 of the specification:a) Supply and installation of 2 fittings of 240W LED lamps with all accessories for Complete lighting of outdoor Switch yard area as per clause 16.0 of section 7 of the specifications. 45 b) Supply and installation of 35W LED tube on tubular steel poles along with the boundary wall at a distance of 30 meter as per as per clause 16.0 of section 7 of the specification 46 c) Complete lighting of road and street by providing 90W LED lamps on tubular steel poles at a distance of 15meter along the roads and streets as per as per clause 16.0 of section 7 of the specification. 47 d) Supply and installation of post top lantern 40W LED Lamps with all complete accessories at the entrance gate of sub-station. 48 e) Supply and installation of 40W LED Lamps with all complete accessories on corners of control room building. 49 Complete Substation automation system of 66/11kV substations including hardware (along with transducers) & software along with associated equipment for the bays (bay as defined in the technical specification, sec-substation automation system) as per technical specification.66 kV Mussimble Present FutureSr. No.DescriptionNo. of 66 kV Bays1. T/F2 12.Line 223. B/C 1-66kV SadopurNo. of 66 kV Bays Sr. No.DescriptionPresent Future1. T/F 2 6*2.Line3 3. B/C 1 * As per space available in GELO. Accordingly, provision shall be made in SAS to accommodate future scope along with present scope. Note: signals from protection relays in 11 kV incomer would also be wired to substation automation system (SAS) 50 Time synchronization equipment 51 High wall type split AC unit of 2 Ton capacity for SCADA room & C&R Panel room (as per technical specification). 52 Computer system (SFF) with: Intel core i5 processor with 11th generation or higher as specified in Section-04 53 Multi-Function Monochromatic Laser Jet Machine (A4-25 PPM or more) with print copy and scan function, Duplexing feature, composite cartridge, ADF, A4 or larger flatbed size, Networking and wi-fi both, at least 1 input tray, 3 years on site OEM warranty 54 BOM FOR SAMAST COMPLIANT IEM (ON SEPARATE CUBICLE) FOR 11KV I/C:1 (a) 3P4W Interface Energy Meters (ABT Type) 0.2s Class 1A with TTB & BCS (2 No. for each 11 kV Incomer) 55 1 (b) Testing of IEM System from NABL accredited lab 56 2. Wired Indoor Meters Panel suitable for 8 meters 57 3. 16 P Industrial Grade un-managed Network switch 58 4 (a) Data concentrator unit (DCU)/communication Gateway (IG) with dual SIM Modern alongwith enclosure and accessories 59 4 (b) 3C x 2.5 sq. mm Un-armoured cable for DCU and Switches 60 5. Cat-6 cable-unshielded 61 6. PVC conduit pipe-3/4 with accessories for Cat-6 cable (In line with cat-6 cable) 62 7. Armored Fibre Optic Cable (2 pair) 63 8. HDPE conduit - 40/33 with accessories (In line with armored cable for CT/PT) 64 9. 4Cx4 Sqmm armoured cable for PT 65 10.4Cx4 Sqmm armoured cable for CT 66 48V 120AH Battery Bank San Tubular 67 48V SMPS Battery Charger (for 48 V 120 AH Battery Bank San Tubular Battery) 68 For 220 kV Substation, BBMB, Dhulkote: 1. The supply of Numerical Line Current Differential-cum- Back up Distance Protection Relay for C&R Panels (non-SAS compliant)installed at 220 kV Substation, BBMB, Dhulkote (for 66 kV D/C Dhulkote - Saddopur Lines). 69 2. The erection/ retrofitting, testing & commissioning of Numerical Line Current Differential-cum- Back up Distance Protection Relay in place of existing Distance Protection Relay on the existing C&R Panels (non-SAS compliant) above at sr. no. 68 installed at 220 kV Substation, BBMB, Dhulkote (for 66 kV D/C Dhulkote - Saddopur Lines) shall be the part of scope of successful bidder. 70 Bolted type 11kV tension string assembly with 3 numbers Anti FOG type disc insulators (E&M strength 9000 kg) per string with all hardware accessories including ball & socket connections and tension clamp sets suitable for twin tarantulla conductor. Alternatively the bidder may quote silicon polymer composite insulator string in place of Disc Insulators 71 66 kV Bolted type tension string assembly with 6 numbers Anti FOG type disc insulators (E&M strength 9000 kg) per string with all hardware accessories including ball & socket connection and tension clamp set suitable for single zebra conductor. Alternatively the bidder may quote silicon polymer composite insulator string in place of Disc Insulators 72 66 kV Bolted type tension string assembly with 6 numbers Anti FOG type disc insulators (E&M strength 9000 kg) per string with all hardware accessories including ball & socket connection and tension clamp set suitable for twin zebra conductor. Alternatively the bidder may quote silicon polymer composite insulator string in place of Disc Insulators 73 66 kV bolted type suspension string assembly with 5 numbers Anti FOG type disc insulators (E&M strength 9000 kg) per string with all hardware accessories including ball & socket connections and suspension clamp set suitable for single zebra conductor. Alternatively the bidder may quote silicon polymer composite insulator string in place of Disc Insulators 74 66 kV bolted type suspension string assembly with 5 numbers Anti FOG type disc insulators (E&M strength 9000 kg) per string with all hardware accessories including ball & socket connections and suspension clamp set suitable for twin zebra conductor. Alternatively the bidder may quote silicon polymer composite insulator string in place of Disc Insulators 75 Boltless C-Type Wedge connectors matching with conductor size. 76 Copper lugs glands, PVC ferrules for control cabling. 77 Fiber cleats, Aluminium clamps, bolts, nuts, washers etc., for fixing control cables in trenches. 78 Galvanized iron perforated tray with side coupler plate bolts, nuts, washers and clamps etc. of size 75x25x2 mm, 150x25x2mm, 100x25x2mm etc. & G.I. Conduits of 50mm/100mm dia from equipment to main trench as per Section-7, Switchyard erection. 79 ACSR Zebra Conductor (approx.) 80 AAC Twin Tarantulla Conductor (approx.) 81 7/3.15 GS Earth wire 82 Spacers for TwinTarantulla/ZebraConductor 83 U-bolt 20mm dia. 84 Mandatory spares for hardware/mechanical/Electrical auxiliaries to be supplied. 10 % of the finally approved quantities for item mentioned from Sr. No. 70 to 74. 85 2.5 ″ dia HDD/PVC pipe for 4c x 4 mm2 c/cable from CT, VT to maintaining system as per sec-5, chapter-5. 86 Item for associated structure workA)‘‘Lattice type steel structure for 66kV AIS Mussimble (Yamuna Nagar) & Sadopur (Ambala), Supply of material, preparation of fabrication drawing, galvanizing and delivery of lattice type steel structure for tower and beams for 66/11KV switchyard fabricated from steel conforming to IS: 2062 including nuts-bolts gusset plates foundation bolts and other accessories as per drawings supplied by the owner.66kV Cable support structure of galvanized iron along with foundation to be designed by bidder as per site requirement/size of cableMain S/Stn. tower and beam:a)Tower type CT-4 87 b) Tower type CT-5 88 c) Tower type CT-6 89 d) Tower type CT-8 90 e) Beam type CB-6 91 f) Beam type CB-7 92 g) Tower type DT-2 93 h) Tower type DT-3 94 i) Beam type DB-2X 95 B) Equipment Structure:a) 66 kV CT Drg. No. HTD/ST-88R 96 b) 66 kV NCT Drg. No. HTD/ST-145 (if required ) 97 c) 66 kV PT Drg. No. HHW/ST-66 98 d) 66 kV Surge Arrestor Drg. No. HTD/ST-89 99 e) 66 kV Isolator Drg. No. HTD/ST-87R 100 f) 66 kV L&E Switch Drg. HTD/ST-87R 101 g) 11 kV NCT Drg. HTD/ST-149 (if combined structure used) or 11 kV NCT Drg. HTD/ST-88R (if required). 102 1. EARTH WORK 1.1 Earth filling with good earth (as per satisfaction of Executive Engineer/Civil Works Division), laying in layers (as per specification), dressing, including carriage, irrespective of lead, loading, unloading, watering and compaction in layers with roller including compensation of earth complete in all respect. 103 1.2 DewateringDewatering of subsoil water for lowering of water table to enable excavation of earth, concreting for all type of works and backfilling, by boring of tube wells or deploying well point system so that continuous lowering of water table is made till completion of work, without disturbing the soil characteristics. The rate shall include all type of expenditure for required dewatering arrangements. 104 2. FOUNDATIONSWORK FOR 66 KV MUSSIMBLE:Supply of labour, T&P, material and construction of RCC footings & pedestals etc. for steel gantry and equipment structures complete in all respects as per HVPNL standard drawing, technical specifications including cost of excavation, concreting, cement, reinforcement steel, form work, grouting, holding down bolts, backfilling etc.and other items not mentioned herein but required for the completion of work.A. GANTRY TOWERS i) CT-4 105 ii) CT-5 106 iii) CT-6 107 iv) CT-8 108 v) DT-2 109 vi) DT-3 110 B. EQUIPMENT 66kV sidei) 66KV LA 111 ii) 66KV CVT/PT 112 iii) 66KV CT 113 iv) 66kV L&E & Isolator 114 v)66kV NCT 115 11kV sidei) 11kV NCT 116 3. FOUNDATIONS WORK FOR 66 KV SADOPUR:Design engineering & supply of labour, T&P, material and construction of RCC footings & pedestals etc. for steel gantry and equipment structures complete in all respects as per technical specifications & approved drawings including cost of excavation, concreting, cement, reinforcement steel, form work, grouting, holding down bolts, backfilling etc.and other items not mentioned herein but required for the completion of work.The successful bidder shall develop the designs & drawings as per the soil investigation report attached in specification and shall get these checked/vetted from any professsional institute as per contract before final approval.A. GANTRY TOWERS i) CT-4 117 ii) CT-5 118 iii) CT-6 119 iv) CT-8 120 v) DT-2 121 vi) DT-3 122 B. EQUIPMENT 66kV sidei) 66KV LA 123 ii) 66KV CVT/PT 124 iii) 66KV CT 125 iv) 66kV L&E & Isolator 126 v)66kV NCT 127 11kV sidei) 11kV NCT 128 4. BREAKER FOUNDATIONDesign, engineering, supply of labour, material, equipment & const. of foundations for breaker including all associated works PCC, RCC, structural steel, steel reinforcement & any other item not specifically mentioned herein but reqd. for completion of work as per tech. spec.i) 66 kV Breaker Foundation 129 5. RoadsSupply of labour, material and construction of cement concrete roads and walkways/shoulders from NH/SH/etc. to Switch yard/Switch house building as per GELO/CLO as per sectional detail drawing no. HCD/SK-181 R1 and technical specification.i. 6.0m wide road (Near main gate of substation) 130 ii. 3.66 wide road 131 6. CAPACITOR BANK FOUNDATIONSDesign, Engg. & supply of labour, material & construction of foundations for capacitor bank with capacitor unit (with allied equipments) & series Reactor etc. including chain link fencing 1.8M height around cap. bank complete in all respect including any other items not specifically mentioned herein but required for completion of job as per technical specification.i) 9000 KVAR 12.65 kV capacitor bank 132 7. ROAD CULVERTDesign, Engineering and const. of Pipe culvert(s) at suitable locations under the approach road (from main PWD/ HUDA/Municipal/Village road to the sub-station entry point) including, cost of labour, material complete in all respects as per I.R.C. Standards. 133 8. TRANSFORMER FOUNDATION FOR 66 KV MUSSIMBLE : 8.1 Construction of transformer foundation including all associated works, RCC, PCC, reinforcement steel, misc. structural steel and other items not mentioned herein but required for completion of work as per technical specifications & approved drgs. In case extra foundation(s) has/have to be constructed (as per approved T/F drawing) to complete the job, nothing extra would be paid on this count..25/31.5MVA,66/11kV T/F foundationcomplete in all respect. 134 9. TRANSFORMER FOUNDATIONWORK FOR 66 KV SADOPUR: 9.1 Design Engineering & construction of transformer foundation including all associated works, RCC, PCC, reinforcement steel, misc. structural steel and other items not mentioned herein but required for completion of work as per technical specifications & approved drgs. In case extra foundation(s) has/have to be constructed (as per approved T/F drawing) to complete the job, nothing extra would be paid on this count.The successful bidder shall develop the designs & drawings as per the soil investigation report attached in specification and shall get these checked/vetted from any professsional institute as per contract before final approval..25/31.5MVA,66/11kV T/F foundationcomplete in all respect. 135 10 Statipon Transformer Foundation work: Design, Engg., supply of labour, material and construction of foundation for station transformer including all associated works, RCC, PCC, Reinforcement steel, misc. structural steel and other items not mentioned herein but required for the completion of work as per technical specifications.11/0.4kV 200KVA Station T/F 136 11. OUTDOOR CABLE TRENCHES:Supply of labour, material such as cement, reinforcement steel, GI angles, flats, PCC & brick pillars below cable trenches for construction of Out-Door Cable Trenches (ODCT) of required depth/ type with pre-cast RCC covers including associated works like Cable Trench Culverts crossings for roads and sumpit-cum-pump chamber with 2HP motor of reputed make, starter, volt meter, amp-meter etc. as per approved trench layout plan, HVPNL drgs. & tech. specs. complete in all respecti) D-type trench 137 ii) E-type trench 138 iii) F-type trench 139 iv) G-type trench 140 v) H-type trench 141 vi) Road culvert 142 vii) Sump Pit Cum Pump Chamber 143 12. SITE SURFACING:12.1Providing, supplying & laying 100mm thick in two layers of 50mm each of 20mm nominal size uncrushed/crushed/ broken stone pebbles gravel fill including dressing, rolling & compacting complete in all respects as per specs. & instructions of engineer incharge. 144 12.2 Providing, supplying & laying 100mm thick PCC (1:4:8) using 20mm nominal coarse aggregates and supplying & spreading 100mm thick layer of 40mm nominal size uncrushed/ crushed/broken stone pebbles over the PCC including construction of toe wall (exposed wall plastered with cement mortar 1:5) to hold 40mm single size uncrushed/ crushed /broken stone pebbles wherever required in the bays covered under the present scope as detailed in the GELO & instructions of engineer incharge. 145 13. BOUNDARY WALL13.1 Supply of labour, T&P, material & construction of front, side & U/C boundarybelow DPC level as per GELO/CLO, tech. spec. & HVPNL drgs including excavation, PCC, brickwork, back filling, plaster, painting etc. complete in all respects. 146 13.2 Supply of labour, material and construction of front, C & U/C boundary walls above DPC including main gate foundationsas per GELO/CLO, technical specifications. & HVPNL drg. HCD/TS-1176 R3 including DPC complete in all respect.i. 6 ft. high U/C B/wall with barbed wire on angles at top. 147 ii. 4½ ft. high front wall including providing grill at top of wall & construction of gate pillars. 148 iii. 4½ ft. high side wall with barbed wire on angles at top of wall. 149 14. CONTROL ROOM BUILDING FOR 66 KV MUSSIMBLE: Supply of labour, material, T&P and construction of control room building complete in all respect as per tech. specs. including exterior weather proof paint, interior emulsion, all internal services like water supply including supply & providing of 5000ltr. capacity double layer Sintex/Diplast PVC tank, Sewerage system, electrification including wiring, modular switches, maximum 20W 4ft. long LED tubes with fittings minimum 1960 lumens, ceiling/exhaust fans, Finishing, Plinth protection, flooring, Indoor trenches, Soakage pit near the switch house building, Rcc pipe around the building to drain of water,connection of sewerage system to Soakage pit/Sewerage system of local authorities (as applicable), connection to main water supply system of local authority, bore (Tubewell) (as applicable) etc. & any other item not mentioned herein but required for completion of works. 150 15. CONTROL ROOM BUILDING FOR 66 KV SADOPUR:The design of foundation below plinth level is in the scope of successful bidder. However, the architectural design and the structural design above plinth level shall be kept same as per HVPNL standard drawings attached with bidding documents. Design engineering, supply of labour, material, T&P and construction of control room building complete in all respect as per tech. specs. including exterior weather proof paint, interior emulsion, all internal services like water supply including supply & providing of 5000ltr. capacity double layer Sintex/Diplast PVC tank, Sewerage system, electrification including wiring, modular switches, maximum 20W 4ft. long LED tubes with fittings minimum 1960 lumens, ceiling/exhaust fans, Finishing, Plinth protection, flooring, Indoor trenches, Soakage pit near the switch house building, connection of sewerage system to Soakage pit/Sewerage system of local authorities (as applicable), connection to main water supply system of local authority, bore (Tubewell) (as applicable) etc. & any other item not mentioned herein but required for completion of works.The successful bidder shall develop the designs & drawings as per the soil investigation report attached in specification and shall get these checked/vetted from any professsional institute as per contract before final approval. 151 16. U/C FENCING & GATESProviding & fixing chain link fencing including foundations, GI angle iron posts and gate(s) complete as per electrical layout & tech. spec. & as per drawing attached. 152 17. PCC PAVEMENTConstruction of PCC pavement in front, rear or side (as per site requirement of the switch house building) as per drawing no. HCD/SK-172 & technical specifications. 153 18. DRAINAGE–CUM-RAIN HARVESTING SYSTEM for 66 kV substation Mussimble 18.1 Supply of labour, material for construction ofrecharge structures with bore well(s) as per HVPN drawings & specs. complete in all respect . The location of recharge structures shall preferably be located on corner(s) of the substation and shall be got decided from the concerned Engineer in-Charge on the basis of surroundings of the substation(s). In case ground water table is less than 8m from FGL, rain harvesting well shall not be constructed (the drainage system with sump pit is to be constructed as per item mentioned below). 154 18.2 The successful bidder shall evolve design & drawing for drains, manholes with RCC covers andsettlement tankincluding preparation of drainage layout drawing for disposal of rain water from building’s roof top & switch yard (s/stn.) area into respective bore well(s) in such a way that there shall be no ponding of water on the roof and switch yard (s/stn.). The layout so developed shall be got approved from the employer. The location of sump-pit-cum-pump chamber shall preferably be locatedon corner(s) of the s/stn. and shall be got decided from the concerned Engineer in-Charge on the basis of surroundings of the substation(s). The successful bidder will also supply labour and material for construction of sump-pit-cum-pump chamber as per HVPNL drgs. & provide one no. non clog pump(s) of 5HP of reputed make capacity with main switch, starter, volt meter, Amp. Mtr. etc. (for each sump pit) for disposal of excess water to outfall point. Any other item(s) not mentioned herein but is/are required for completion of works shall be done by the successful bidder without any extra cost to the employer.i)Drain Section-1 155 ii) Drain Section-2 156 iii) Drain Section-3 157 iv) Road Crossing 158 v) Trench Crossing 159 vi) Sump Pit Cum Pump Chamber 160 19. DRAINAGE–CUM-RAIN HARVESTING SYSTEM for 66 kV substation Sadopur The successful bidder shall evolve design & drawing for drains, manholes with RCC covers andsettlement tankincluding preparation of drainage layout drawing for disposal of rain water from building’s roof top & switch yard (s/stn.) area into respective bore well(s) in such a way that there shall be no ponding of water on the roof and switch yard (s/stn.). The layout so developed shall be got approved from the employer. The location of sump-pit-cum-pump chamber shall preferably be locatedon corner(s) of the s/stn. and shall be got decided from the concerned Engineer in-Charge on the basis of surroundings of the substation(s). The successful bidder will also supply labour and material for construction of sump-pit-cum-pump chamber as per HVPNL drgs. & provide one no. non clog pump(s) of 5HP of reputed make capacity with main switch, starter, volt meter, Amp. Mtr. etc. (for each sump pit) for disposal of excess water to outfall point. Any other item(s) not mentioned herein but is/are required for completion of works shall be done by the successful bidder without any extra cost to the employer.The successful bidder shall develop the designs & drawings and shall get these checked/vetted from any professsional institute as per contract before final approval.i)Drain Section-1 161 ii) Drain Section-2 162 iii) Drain Section-3 163 iv) Road Crossing 164 v) Trench Crossing 165 vi) Sump Pit Cum Pump Chamber 166 20. RCC M-20 for 66 kV substation Mussimble inclusive of labour, material, shuttering, steel reinforcement etc. complete in all respects to compensate excess quantity required to be executed due to difference in existing ground level and the formation level to be fixed after contouring or difference on account of revised drawing issued at the time of construction and the tender drawing. 167 21. RCC Retaining wall for 66 kV substation Sadopur Design engineering, supply of labour, material and construction of T/L shaped RCC retaining wall below DPC to retain the earth filling complete in all respect. The successful bidder shall develop the designs & drawings as per the soil investigation report attached in specification and shall get these checked/vetted from any professsional institute as per contract before final approval.Difference between NGL & FGL from 2.5 to 3.5 mtr. 168 22. Distamtlement for 66 kV substation Sadopur :-Dismantling of existing residential quarters, OHT and underground tank etc. Dismantling including foundations of following structure. The material whatsoever shall be the property of the successful bidder. The dismantled material shall not be allowed for reuse at any of the sub-stations; however, HVPNL may allow use of bricks for brick ballast purpose only.Dismantling of existing residential quarters, Overhead tank, toilet, boundary wall and underground tank etc complete in all respect.
Contract Date : Ref. Documents   |   Contract Value : Ref. Documents
BRR : 9334435 Tender For Creation Of Receiving Stations- 1 A-SUPPLY PART-6.30 MVA HASTI 2 33 KV LINE BAY OF SINGLE BUS SCHEME (INCLUDING ALL FOUNDATION WORKS) 3 33 KVVCB (36 KV, 1250 A, 26.2 KA, outdoor type) 4 33 KV C&R panel along with O/C, E/F relay (IEC 61850) Mimic diagram, voltmeter, ammeter, annunciation windows with annunciation relays, 3 Phase Trivector meter DLMS compliant RS 485 port 5 33 KV Isolatorwith earthing blade(36 KV ,1250A.Outdoor.3 pole,25KA) 6 33 KV Isolatorwithout earthing blade(36 KV ,1250A.Outdoor.3 pole,25KA) 7 33 KV Current Transformer (33KV,Single Phase,Multi ratio,multi core ,Outdoor) 1 No per Phase 8 33 KV PT (33KV/110V,1phase,multicore,Outdoor)(1No per phase) 9 30 KV Lightening Arrestor (30KV,10KA,Station Class.ZNO.Polymer) Gapless 10 33 kv Post Insulators polymer type , 36 kv, 235 kv impulse, creepage distance 1224 mm 11 STEEL STRUCTURES/PIPE STRUCTURE(INCLUDING ALL FOUNDATION WORKS) 12 Pipe Nominal bore 200, 5.9 mm thick 13 Galvanised steel structures 14 Galvanized nuts and bolts 15 CONTROL CABLES(INCLUDING ALL FOUNDATION WORKS) 16 12 core 2.5 mm2, copper armoured, 1.1 kv grade, ISI FRLS 17 4 core 2.5 mm2copper armoured, 1.1 kv grade, ISI FRLS 18 2 core 2.5 mm2copper armoured, 1.1 kv grade, ISI FRLS 19 Lugs & Ferrules etc. 20 CONDUCTOR AND HARDWARE(INCLUDING ALL FOUNDATION WORKS) 21 ACSR Conductor Panther 22 T-Clamp 23 Single Tension fitting 24 PolymerComposit type Disc Insulators.36KV Lighting bimpulse 170KV Positive and 180KV Negative,Creepage distance 900mm,Minimum failing load70 KN 25 Earth Wire 7/4 sqmm 26 G.I Flat 50*6 mm 27 SUB-STATION MAIN EQUIPMENT TRANSFORMER BAY(INCLUDING ALL FOUNDATION WORKS) 28 33 KVVCB (36 KV, 1250 A, 26.2 KA, outdoor type) 29 33 KV Isolatorwithout earthing blade(36 KV ,1250A.Outdoor.3 pole,25KA) 30 33 KV Current Transformer (33KV,Single Phase,Multi ratio,multi core ,Outdoor) 1 No per Phase 31 30 KV Lightening Arrestor (30KV,10KA,Station Class.ZNO.Polymer) Gapless 32 33 KV C&R panel along with O/C, E/F relay (IEC 61850) Mimic diagram, voltmeter, ammeter, annunciation windows with annunciation relays, 3 Phase Trivector meter DLMS compliant RS 485 port 33 33 kv Post Insulators polymer type , 36 kv, 235 kv impulse, creepage distance 1224 mm 34 STEEL STRUCTURES(INCLUDING ALL FOUNDATION WORKS) 35 Pipe Nominal bore 200, 5.9 mm thick 36 Galvanised steel structures 37 Galvanized nuts and bolts 38 CONTROL CABLES 39 12 core 2.5 mm2, copper armoured, 1.1 kv grade, ISI FRLS 40 6 core 2.5 mm2copper armoured, 1.1 kv grade, ISI FRLS 41 2 core 2.5 mm2copper armoured, 1.1 kv grade, ISI FRLS 42 Lugs & Ferrules etc. 43 CONDUCTOR AND HARDWARE(INCLUDING ALL FOUNDATION WORKS) 44 ACSR Conductor Panther 45 T-Clamp 46 G.I Flat 50*6 mm 47 33/11 KV, 6.30 MVA Power Transformer(INCLUDING ALL FOUNDATION WORKS) 48 33/11KV ONAN,6.30MVA Copper wound,Outdoor type,Conventional Power transformer,Oil filled with OLTC and all accessories including HT and LT Terminal connections with busbars 49 12 Core 2.5mmsq Control Cable Copper Armoured,1.1KV Grade .ISI .FRLS 50 6 Core 2.5mmsq Control Cable Copper Armoured,1.1KV Grade .ISI .FRLS 51 2 Core 2.5mmsq Control Cable Copper Armoured,1.1KV Grade .ISI .FRLS 52 Cost for 11 KV Indoor Switchgear of 33/11 kv Substation (Transformer Bay Scheme) 53 11 KV VCB Panel Board ( 12KV,1250A,25KA, Outdoor ) With over current,earth fault relays (IEC 61850),MIMIC diagram,Voltmeter,Ammeter,annuniaciation windows with annunciation relays,Hooter on individual Panels ,3-phase tri vector Smart meter-5A,DLMS Compliant with RS-485 Port1 Incoming & 4 outgoings 54 11KV Gapless Surge Arrestor,9KV,10KA LA With polymer HousingStation Type 55 11KV (UE)XLPE Power Cables (Armoured) 56 11 kV400 mm² Three Core XLPE Cable (with one spare length) armoured, FRLS 57 11 kV (UE) 3-Core XLPE 120 mm² armoured, FRLS 58 11KVHeat shrink termination Cable Kits (Indoor) 400 mm square (3-core) 59 11KV Heat shrink termination Cable Kits (Outdoor) 400 mm square (3-core) 60 11KV Heat shrink termination Cable Kits (Indoor) 120 mm square(one spare) (3-core) 61 11KV Heat shrink terminationCable Kits (Outdoor) 120 mm square (one spare) (3-core) 62 11 KV isolator, double break, 3 pole, 600 Amp. Horizental mounting type with earth switch Complete 63 11KV GO Set, AB switch 3 phase, 3 pole, 400 Amps. 64 100 KVA, 11/.433 KV,Auxiliary Transformer,3 Phase Distribution Transformer with bimetallic terminal connectors ,energy level -2,Al Wound. 65 StT Poles 9 mtrs long 66 Galvanised iron of sorts 67 120 mm2 PVC 4 core cable,Armoured FRLS 68 MCCB 200 Amp 69 Cement bottomng 1:2:4 mix as per REC standards 0.5cum per pole 70 Earthing of 100KVA substation --Excavation ofearth pit of dia650 mm & depth 3000 mm, installation ofEarthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 75 mm x10 mm& 50 mm x 6 mmfor connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. 71 Earthing complete GI pipe 40 mm or GI rod 20mm 2.5 mtr long through G.I Strip 72 COMMON MISCELLANEOUS EQUIPMENTS 73 a) Battery Bank 30 V, 100 AH, of 15 No. cells of 2 V each, sealed maintenance free VRLA type, high impact Polyprophelene copolymer container, flame retardant with stand 74 b) 30 V, 100 AH, float-cum-boost charger with full wave rectification for 220 V, 1 phase, 50 HZ AC input supply. 75 Distribution panel (30V, DC) made of CRCA thickness not less than 2 mm ,Powder coated degree of protection IP 43 for two number battery incoming supplywith 2No. 63 Amp. DP MCB for incoming supplydouble bus bar of adequate size,twelve number DP DC MCB(0-32A) including indication lamp and cables and other accessories 76 Distribution panel (415 V, AC)made of CRCA thickness not less than 2 mm ,Powder coated degree of protection IP 43 200A Switch fuse disconnector for incoming supply and five numbers TPN MCBs(16-125A) and five number DP MCB(0-32A),rectangular bus bar suitable for 200 A continous supply including indication lamp cables and other accessories. 77 Telecommunication facilities including cctvs set (4nos cameras ) LED Display (32) 78 CIVIL WORKS 79 Compound walling of identified land by way of Mass Concrete in Foundation and 228mm bricks of 2M height 80 Chain-link Fencing of 33kv Yard of Substation by way of Mass Concrete in Foundations and chain-link fencing of 6 ft height. 81 33/11kv power Transformer Foundation 82 33kv Equipment Foundation and gantry foundation 83 Earthing Mat complete job GI flat 50x8 mm 84 Earthing electrode ( 3 meters long, 40 mm dia GI pipe) through GI strips 85 33kv Yard Concreting / Metalling 86 Underground Water tank 10000 Ltrs. 87 Overhead water tank 2000Ltr 88 Control room Building including wash room ,pantry room .sanitary fittings tile works ,kota stone in control roominternal wiring,painting and fixing of electrical appliances like lights ,fans,geysers job complete finish 89 Shift Quarters for Je and SBA including wash room ,pantry room .sanitary fittings tile works ,kota stone in control roominternal wiring,painting and fixing of electrical appliances like lights ,fans,geysers job complete finish 90 Truss for control room building 1.3xPlinth area .Providing and fixing of Steel Truss including provision for colur coated Roofing 158 sqm 91 Development of identified land by way of removing weeds, wild grass and undulation if any, ornamental land scraping and growing of ornamental trees in un built areas and road sides and development of road along with surface drain. 92 Construction of semi Pucca B/Wall of 2.0 Mtr. Height (Length=100 mtr) 93 Dry random rubble masonry with hard stone in foundation and plinth: Without bond stone 94 Construction of Pucca Drain 95 Yard Lighting ( 6 Nos yard and 02 Nos CR back side) on 9m Long Poles 96 CAPACITOR BANK 97 12 kV Capacitor Bank with VCB Panel with complete arrancement for conection with 11 kV incomer panel , Series Reactor, Isolator, RVT, Surge Arrestors, HT Cable with termination Kits, Control Cables, CRCA Cubicle Panel etc with structure, foundation & accessories. 98 SINGLE BUS OUT (INCLUDING ALL FOUNDATION WORKS) 99 33 KVVCB (36 KV, 1250 A, 26.2 KA, outdoor type) 100 33 KV Isolatorwith earthing blade(36 KV ,1250A.Outdoor.3 pole,25KA) 101 33 KV Current Transformer (Single Phase,Multi ratio,multi core ,Outdoor) 102 30 KV Lightening Arrestor (30KV,10KA,Station Class.ZNO.Polymer) Gapless 103 33 KV C&R panel along with O/C, E/F relay (IEC 61850) Mimic diagram, voltmeter, ammeter, annunciation windows with annunciation relays, 3 PHASE Trivector meter DLMS compliant RS 485 port 104 33 kv Post Insulators polymer type , 36 kv, 235 kv impulse, creepage distance 1224 mm 105 33 KV PT (33KV/110V,1phase,multicore,Outdoor)(1No per phase) 106 STEEL STRUCTURES(INCLUDING ALL FOUNDATION WORKS) 107 Galvanised steel structures 108 Galvanized nuts and bolts 109 Pipe Nominal bore 200, 5.9 mm thick 110 CONTROL CABLES 111 10 /12 core 2.5 mm2, copper armoured, 1.1 kv grade, ISI FRLS 112 8 core 2.5 mm2copper armoured, 1.1 kv grade, ISI FRLS 113 2 core 2.5 mm2copper armoured, 1.1 kv grade, ISI FRLS 114 Lugs & Ferrules etc. 115 CONDUCTOR AND HARDWARE(INCLUDING ALL FOUNDATION WORKS) 116 ACSR Conductor Panther 117 T-Clamp 118 Single Tension fitting 119 PolymerComposit type Disc Insulators.36KV Lighting bimpulse 170KV Positive and 180KV Negative,Creepage distance 900mm,Minimum failing load70 KN 120 Earth Wire 7/4 sqmm 121 G.I Flat 50*06 mm 122 33 KV LINE (INCLUDING ALL FOUNDATION WORKS) 123 11 Mtr. Long ST Pole(For new line) ST-410 SP56 124 GI Channel X-arm including clamps and braces 125 100 mm² ACSR DogConductor 126 PG Clamps for 100 mm² ACSR Conductor 127 33kV Polymeric composite Pin Insulator 36kV, 10kN,Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm 128 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm with fittings 129 Galvinized Nuts and Bolts. 130 Danger Plates with Clamps 131 Anti-Climbing Device with Clamps 132 Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. 133 Red Oxide 134 Aluminium Paint 135 Cement bottoming 1:2:4 mix as per REC standards .6cum /pole 136 Stone Pad (300 mm x 300 mmx 75 mm) 137 Aluminium Jointing Sleeves 138 Galvanised Stay Set with 50 x 8 mm stay clamp, guy insulator(2Nos.), anchor plate (300x 300 x 8 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 20 mm diameter solid GS stay rod & 7/4.00 mm dia GI stranded wire complete 139 Guard netting 140 A-SUPPLY PART-6.30 MVA DOOL 141 33 KV LINE BAY OF SINGLE BUS SCHEME(INCLUDING ALL FOUNDATION WORKS) 142 33 KVVCB (36 KV, 1250 A, 26.2 KA, outdoor type) 143 33 KV C&R panel along with O/C, E/F relay (IEC 61850) Mimic diagram, voltmeter, ammeter, annunciation windows with annunciation relays, 3 Phase Trivector meter DLMS compliant RS 485 port 144 33 KV Isolatorwith earthing blade(36 KV ,1250A.Outdoor.3 pole,25KA) 145 33 KV Current Transformer (33KV,Single Phase,Multi ratio,multi core ,Outdoor) 1 No per Phase 146 33 KV PT (33KV/110V,1phase,multicore,Outdoor)(1No per phase) 147 30 KV Lightening Arrestor (30KV,10KA,Station Class.ZNO.Polymer) Gapless 148 33 kv Post Insulators polymer type , 36 kv, 235 kv impulse, creepage distance 1224 mm 149 STEEL STRUCTURES/PIPE STRUCTURE(INCLUDING ALL FOUNDATION WORKS) 150 Pipe Nominal bore 200, 5.9 mm thick 151 Galvanised steel structures 152 Galvanized nuts and bolts 153 CONTROL CABLES 154 12 core 2.5 mm2, copper armoured, 1.1 kv grade, ISI FRLS 155 4 core 2.5 mm2copper armoured, 1.1 kv grade, ISI FRLS 156 2 core 2.5 mm2copper armoured, 1.1 kv grade, ISI FRLS 157 Lugs & Ferrules etc. 158 CONDUCTOR AND HARDWARE 159 ACSR Conductor Panther 160 T-Clamp 161 Single Tension fitting 162 PolymerComposit type Disc Insulators.36KV Lighting bimpulse 170KV Positive and 180KV Negative,Creepage distance 900mm,Minimum failing load70 KN 163 Earth Wire 7/4 sqmm 164 G.I Flat 50*6 mm 165 SUB-STATION MAIN EQUIPMENT TRANSFORMER BAY(INCLUDING ALL FOUNDATION WORKS) 166 33 KVVCB (36 KV, 1250 A, 26.2 KA, outdoor type) 167 33 KV Isolatorwithout earthing blade(36 KV ,1250A.Outdoor.3 pole,25KA) 168 33 KV Current Transformer (33KV,Single Phase,Multi ratio,multi core ,Outdoor) 1 No per Phase 169 30 KV Lightening Arrestor (30KV,10KA,Station Class.ZNO.Polymer) Gapless 170 33 KV C&R panel along with O/C, E/F relay (IEC 61850) Mimic diagram, voltmeter, ammeter, annunciation windows with annunciation relays, 3 Phase Trivector meter DLMS compliant RS 485 port 171 33 kv Post Insulators polymer type , 36 kv, 235 kv impulse, creepage distance 1224 mm 172 STEEL STRUCTURES(INCLUDING ALL FOUNDATION WORKS) 173 Pipe Nominal bore 200, 5.9 mm thick 174 Galvanised steel structures 175 Galvanized nuts and bolts 176 CONTROL CABLES 177 12 core 2.5 mm2, copper armoured, 1.1 kv grade, ISI FRLS 178 6 core 2.5 mm2copper armoured, 1.1 kv grade, ISI FRLS 179 2 core 2.5 mm2copper armoured, 1.1 kv grade, ISI FRLS 180 Lugs & Ferrules etc. 181 CONDUCTOR AND HARDWARE(INCLUDING ALL FOUNDATION WORKS) 182 ACSR Conductor Panther 183 T-Clamp 184 G.I Flat 50*6 mm 185 33/11 KV, 6.30 MVA Power Transformer(INCLUDING ALL FOUNDATION WORKS) 186 33/11KV ONAN,6.30MVA Copper wound,Outdoor type,Conventional Power transformer,Oil filled with OLTC and all accessories including HT and LT Terminal connections with busbars 187 12 Core 2.5mmsq Control Cable Copper Armoured,1.1KV Grade .ISI .FRLS 188 6 Core 2.5mmsq Control Cable Copper Armoured,1.1KV Grade .ISI .FRLS 189 2 Core 2.5mmsq Control Cable Copper Armoured,1.1KV Grade .ISI .FRLS 190 Cost for 11 KV Indoor Switchgear of 33/11 kv Substation (Transformer Bay Scheme) 191 11 KV VCB Panel Board ( 12KV,1250A,25KA, Outdoor ) With over current,earth fault relays (IEC 61850),MIMIC diagram,Voltmeter,Ammeter,annuniaciation windows with annunciation relays,Hooter on individual Panels ,3-phase tri vector Smart meter-5A,DLMS Compliant with RS-485 Port1 Incoming & 4 outgoings 192 11KV Gapless Surge Arrestor,9KV,10KA LA With polymer HousingStation Type 193 11KV (UE)XLPE Power Cables (Armoured) 194 11 kV400 mm² 3-Core XLPE Cable (with one spare length) armoured, FRLS 195 11 kV (UE) 3-Core XLPE 120 mm² armoured, FRLS 196 11KVHeat shrink termination Cable Kits (Indoor) 400 Sqmm square (3-core) 197 11KV Heat shrink termination Cable Kits (Outdoor) 400 mm square (3-core) 198 11KV Heat shrink termination Cable Kits (Indoor) 120 mm square(one spare) (3-core) 199 11KV Heat shrink terminationCable Kits (Outdoor) 120 mm square (one spare) (3-core) 200 11 KV isolator, double break, 3 pole, 600 Amp. Horizental mounting type with earth switch Complete 201 11KV GO Set, AB switch 3 phase, 3 pole, 400 Amps. 202 100 KVA, 11/.433 KV,Auxiliary Transformer,3 Phase Distribution Transformer with bimetallic terminal connectors ,energy level -2,Al Wound. 203 StT Poles 9 mtrs long 204 Galvanised iron of sorts 205 120 mm2 PVC 4 core cable,Armoured FRLS 206 MCCB 200 Amp 207 Cement bottomng 1:2:4 mix as per REC standards 0.5cum per pole 208 Earthing of 100KVA substation --Excavation ofearth pit of dia650 mm & depth 3000 mm, installation ofEarthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 75 mm x10 mm& 50 mm x 6 mmfor connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. 209 Earthing complete GI pipe 40 mm or GI rod 20mm 2.5 mtr long through G.I Strip 210 COMMON MISCELLANEOUS EQUIPMENTS 211 a) Battery Bank 30 V, 100 AH, of 15 No. cells of 2 V each, sealed maintenance free VRLA type, high impact Polyprophelene copolymer container, flame retardant with stand 212 b) 30 V, 100 AH, float-cum-boost charger with full wave rectification for 220 V, 1 phase, 50 HZ AC input supply. 213 Distribution panel (30V, DC) made of CRCA thickness not less than 2 mm ,Powder coated degree of protection IP 43 for two number battery incoming supplywith 2No. 63 Amp. DP MCB for incoming supplydouble bus bar of adequate size,twelve number DP DC MCB(0-32A) including indication lamp and cables and other accessories 214 Distribution panel (415 V, AC)made of CRCA thickness not less than 2 mm ,Powder coated degree of protection IP 43 200A Switch fuse disconnector for incoming supply and five numbers TPN MCBs(16-125A) and five number DP MCB(0-32A),rectangular bus bar suitable for 200 A continous supply including indication lamp cables and other accessories. 215 Telecommunication facilities including cctvs set (4nos cameras ) LED Display (32) 216 CIVIL WORKS 217 Compound walling of identified land by way of Mass Concrete in Foundation and 228mm bricks of 2M height 218 Chain-link Fencing of 33kv Yard of Substation by way of Mass Concrete in Foundations and chain-link fencing of 6 ft height. 219 33/11kv power Transformer Foundation 220 33kv Equipment Foundation and gantry foundation 221 Earthing Mat complete job GI flat 50x8 mm 222 Earthing electrode ( 3 meters long, 40 mm dia GI pipe) through GI strips 223 33kv Yard Concreting / Metalling 224 Underground Water tank 10000 Ltrs. 225 Overhead water tank 2000Ltr 226 Control room Building including wash room ,pantry room .sanitary fittings tile works ,kota stone in control roominternal wiring,painting and fixing of electrical appliances like lights ,fans,geysers job complete finish 227 Shift Quarters for Je and SBA including wash room ,pantry room .sanitary fittings tile works ,kota stone in control roominternal wiring,painting and fixing of electrical appliances like lights ,fans,geysers job complete finish 228 Truss for control room building 1.3xPlinth area .Providing and fixing of Steel Truss including provision for colur coated Roofing 158 sqm 229 Development of identified land by way of removing weeds, wild grass and undulation if any, ornamental land scraping and growing of ornamental trees in un built areas and road sides and development of road along with surface drain. 230 Construction of semi Pucca B/Wall of 2.0 Mtr. Height (Length=100 mtr) 231 Dry random rubble masonry with hard stone in foundation and plinth: Without bond stone 232 Construction of Pucca Drain 233 Yard Lighting ( 6 Nos yard and 02 Nos CR back side) on 9m Long Poles 234 ERECTION OF 33 KV LINEDOOL(INCLUDING ALL FOUNDATION WORKS) 235 11 Mtr. Long ST Pole(For new line) ST-410 SP56 236 GI Channel X-arm including clamps and braces 237 100 mm² ACSR DogConductor 238 PG Clamps for 100 mm² ACSR Conductor 239 33kV Polymeric composite Pin Insulator 36kV, 10kN,Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm 240 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm with fittings 241 Galvinized Nuts and Bolts. 242 Danger Plates with Clamps 243 Anti-Climbing Device with Clamps 244 Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. 245 Red Oxide 246 Aluminium Paint 247 Cement bottoming 1:2:4 mix as per REC standards .6cum /pole 248 Stone Pad (300 mm x 300 mmx 75 mm) 249 Aluminium Jointing Sleeves 250 Galvanised Stay Set with 50 x 8 mm stay clamp, guy insulator(2Nos.), anchor plate (300x 300 x 8 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 20 mm diameter solid GS stay rod & 7/4.00 mm dia GI stranded wire complete 251 Guard netting 252 B-ERECTION PART-6.30 MVA HASTI 253 33 KV LINE BAY OF SINGLE BUS SCHEME (INCLUDING ALL FOUNDATION WORKS) 254 33 KVVCB (36 KV, 1250 A, 26.2 KA, outdoor type) 255 33 KV C&R panel along with O/C, E/F relay (IEC 61850) Mimic diagram, voltmeter, ammeter, annunciation windows with annunciation relays, 3 Phase Trivector meter DLMS compliant RS 485 port 256 33 KV Isolatorwith earthing blade(36 KV ,1250A.Outdoor.3 pole,25KA) 257 33 KV Isolatorwithout earthing blade(36 KV ,1250A.Outdoor.3 pole,25KA) 258 33 KV Current Transformer (33KV,Single Phase,Multi ratio,multi core ,Outdoor) 1 No per Phase 259 33 KV PT (33KV/110V,1phase,multicore,Outdoor)(1No per phase) 260 30 KV Lightening Arrestor (30KV,10KA,Station Class.ZNO.Polymer) Gapless 261 33 kv Post Insulators polymer type , 36 KV , 235 KV impulse, creepage distance 1224 mm 262 STEEL STRUCTURES/PIPE STRUCTURE(INCLUDING ALL FOUNDATION WORKS) 263 Pipe Nominal bore 200, 5.9 mm thick 264 Galvanised steel structures 265 Galvanized nuts and bolts 266 CONTROL CABLES(INCLUDING ALL FOUNDATION WORKS) 267 12 core 2.5 mm2, copper armoured, 1.1 kv grade, ISI FRLS 268 4 core 2.5 mm2copper armoured, 1.1 kv grade, ISI FRLS 269 2 core 2.5 mm2copper armoured, 1.1 kv grade, ISI FRLS 270 Lugs & Ferrules etc. 271 CONDUCTOR AND HARDWARE(INCLUDING ALL FOUNDATION WORKS) 272 ACSR Conductor Panther 273 T-Clamp 274 Single Tension fitting 275 PolymerComposit type Disc Insulators.36KV Lighting bimpulse 170KV Positive and 180KV Negative,Creepage distance 900mm,Minimum failing load70 KN 276 Earth Wire 7/4 sqmm 277 G.I Flat 50*6 mm 278 SUB-STATION MAIN EQUIPMENT TRANSFORMER BAY(INCLUDING ALL FOUNDATION WORKS) 279 33 KVVCB (36 KV, 1250 A, 26.2 KA, outdoor type) 280 33 KV Isolatorwithout earthing blade(36 KV ,1250A.Outdoor.3 pole,25KA) 281 33 KV Current Transformer (33KV,Single Phase,Multi ratio,multi core ,Outdoor) 1 No per Phase 282 30 KV Lightening Arrestor (30KV,10KA,Station Class.ZNO.Polymer) Gapless 283 33 KV C&R panel along with O/C, E/F relay (IEC 61850) Mimic diagram, voltmeter, ammeter, annunciation windows with annunciation relays, 3 Phase Trivector meter DLMS compliant RS 485 port 284 33 KVPost Insulators polymer type , 36 kv, 235 kv impulse, creepage distance 1224 mm 285 STEEL STRUCTURES(INCLUDING ALL FOUNDATION WORKS) 286 Pipe Nominal bore 200, 5.9 mm thick 287 Galvanised steel structures 288 Galvanized nuts and bolts 289 CONTROL CABLES 290 12 core 2.5 mm2, copper armoured, 1.1 kv grade, ISI FRLS 291 6 core 2.5 mm2copper armoured, 1.1 kv grade, ISI FRLS 292 2 core 2.5 mm2copper armoured, 1.1 kv grade, ISI FRLS 293 Lugs & Ferrules etc. 294 CONDUCTOR AND HARDWARE(INCLUDING ALL FOUNDATION WORKS) 295 ACSR Conductor Panther 296 T-Clamp 297 G.I Flat 50*6 mm 298 33/11 KV, 6.30 MVA Power Transformer(INCLUDING ALL FOUNDATION WORKS) 299 33/11KV ONAN,6.30MVA Copper wound,Outdoor type,Conventional Power transformer,Oil filled with OLTC and all accessories including HT and LT Terminal connections with busbars 300 12 Core 2.5mmsq Control Cable Copper Armoured,1.1KV Grade .ISI .FRLS 301 6 Core 2.5mmsq Control Cable Copper Armoured,1.1KV Grade .ISI .FRLS 302 2 Core 2.5mmsq Control Cable Copper Armoured,1.1KV Grade .ISI .FRLS 303 Cost for 11 KV Indoor Switchgear of 33/11 kv Substation (Transformer Bay Scheme) 304 11 KV VCB Panel Board ( 12KV,1250A,25KA, Outdoor ) With over current,earth fault relays (IEC 61850),MIMIC diagram,Voltmeter,Ammeter,annuniaciation windows with annunciation relays,Hooter on individual Panels ,3-phase tri vector Smart meter-5A,DLMS Compliant with RS-485 Port1 Incoming & 4 outgoings 305 11KV Gapless Surge Arrestor,9KV,10KA LA with polymer HousingStation Type 306 11KV (UE)XLPE Power Cables (Armoured) 307 11 kV400 mm² Three Core XLPE Cable (with one spare length) armoured, FRLS 308 11 kV (UE) 3-Core XLPE 120 mm² armoured, FRLS 309 11KVHeat shrink termination Cable Kits (Indoor) 400 mm square (3-core) 310 11KV Heat shrink termination Cable Kits (Outdoor) 400 mm square (3-core) 311 11KV Heat shrink termination Cable Kits (Indoor) 120 mm square(one spare) (3-core) 312 11KV Heat shrink terminationCable Kits (Outdoor) 120 mm square (one spare) (3-core) 313 11 KV isolator, double break, 3 pole, 600 Amp. Horizental mounting type with earth switch Complete 314 11KV GO Set, AB switch 3 phase, 3 pole, 400 Amps. 315 100 KVA, 11/.433 KV,Auxiliary Transformer,3 Phase Distribution Transformer with bimetallic terminal connectors ,energy level -2,Al Wound. 316 StT Poles 9 mtrs long 317 Galvanised iron of sorts 318 120 mm2 PVC 4 core cable,Armoured FRLS 319 MCCB 200 Amp 320 Cement bottomng 1:2:4 mix as per REC standards 0.5cum per pole 321 Earthing of 100KVA substation --Excavation ofearth pit of dia650 mm & depth 3000 mm, installation ofEarthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 75 mm x10 mm& 50 mm x 6 mmfor connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. 322 Earthing complete GI pipe 40 mm or GI rod 20mm 2.5 mtr long through G.I Strip 323 COMMON MISCELLANEOUS EQUIPMENTS 324 a) Battery Bank 30 V, 100 AH, of 15 No. cells of 2 V each, sealed maintenance free VRLA type, high impact Polyprophelene copolymer container, flame retardant with stand 325 b) 30 V, 100 AH, float-cum-boost charger with full wave rectification for 220 V, 1 phase, 50 HZ AC input supply. 326 Distribution panel (30V, DC) made of CRCA thickness not less than 2 mm ,Powder coated degree of protection IP 43 for two number battery incoming supplywith 2No. 63 Amp. DP MCB for incoming supplydouble bus bar of adequate size,twelve number DP DC MCB(0-32A) including indication lamp and cables and other accessories 327 Distribution panel (415 V, AC)made of CRCA thickness not less than 2 mm ,Powder coated degree of protection IP 43 200A Switch fuse disconnector for incoming supply and five numbers TPN MCBs(16-125A) and five number DP MCB(0-32A),rectangular bus bar suitable for 200 A continous supply including indication lamp cables and other accessories. 328 Telecommunication facilities including cctvs set (4nos cameras ) LED Display (32) 329 CIVIL WORKS 330 Compound walling of identified land by way of Mass Concrete in Foundation and 228mm bricks of 2M height 331 Chain-link Fencing of 33kv Yard of Substation by way of Mass Concrete in Foundations and chain-link fencing of 6 ft height. 332 33/11kv power Transformer Foundation 333 33kv Equipment Foundation and gantry foundation 334 Earthing Mat complete job GI flat 50x8 mm 335 Earthing electrode ( 3 meters long, 40 mm dia GI pipe) through GI strips 336 33kv Yard Concreting / Metalling 337 Underground Water tank 10000 Ltrs. 338 Overhead water tank 2000Ltr 339 Control room Building including wash room ,pantry room .sanitary fittings tile works ,kota stone in control roominternal wiring,painting and fixing of electrical appliances like lights ,fans,geysers job complete finish 340 Shift Quarters for Je and SBA including wash room ,pantry room .sanitary fittings tile works ,kota stone in control roominternal wiring,painting and fixing of electrical appliances like lights ,fans,geysers job complete finish 341 Truss for control room building 1.3xPlinth area .Providing and fixing of Steel Truss including provision for colur coated Roofing 158 sqm 342 Development of identified land by way of removing weeds, wild grass and undulation if any, ornamental land scraping and growing of ornamental trees in un built areas and road sides and development of road along with surface drain. 343 Construction of semi Pucca B/Wall of 2.0 Mtr. Height (Length=100 mtr) 344 Dry random rubble masonry with hard stone in foundation and plinth: Without bond stone 345 Construction of Pucca Drain 346 Yard Lighting ( 6 Nos yard and 02 Nos CR back side) on 9m Long Poles 347 CAPACITOR BANK 348 12 kV Capacitor Bank with VCB Panel with complete arrancement for conection with 11 kV incomer panel , Series Reactor, Isolator, RVT, Surge Arrestors, HT Cable with termination Kits, Control Cables, CRCA Cubicle Panel etc with structure, foundation & accessories. 349 SINGLE BUS OUT (INCLUDING ALL FOUNDATION WORKS) 350 33 KVVCB (36 KV, 1250 A, 26.2 KA, outdoor type) 351 33 KV Isolatorwith earthing blade(36 KV ,1250A.Outdoor.3 pole,25KA) 352 33 KV Current Transformer (Single Phase,Multi ratio,multi core ,Outdoor) 353 30 KV Lightening Arrestor (30KV,10KA,Station Class.ZNO.Polymer) Gapless 354 33 KV C&R panel along with O/C, E/F relay (IEC 61850) Mimic diagram, voltmeter, ammeter, annunciation windows with annunciation relays, 3 PHASE Trivector meter DLMS compliant RS 485 port 355 33 kv Post Insulators polymer type , 36 kv, 235 kv impulse, creepage distance 1224 mm 356 33 KV PT (33KV/110V,1phase,multicore,Outdoor)(1No per phase) 357 STEEL STRUCTURES(INCLUDING ALL FOUNDATION WORKS) 358 Galvanised steel structures 359 Galvanized nuts and bolts 360 Pipe Nominal bore 200, 5.9 mm thick 361 CONTROL CABLES 362 10 /12 core 2.5 mm2, copper armoured, 1.1 kv grade, ISI FRLS 363 8 core 2.5 mm2copper armoured, 1.1 kv grade, ISI FRLS 364 2 core 2.5 mm2copper armoured, 1.1 kv grade, ISI FRLS 365 Lugs & Ferrules etc. 366 CONDUCTOR AND HARDWARE(INCLUDING ALL FOUNDATION WORKS) 367 ACSR Conductor Panther 368 T-Clamp 369 Single Tension fitting 370 PolymerComposit type Disc Insulators.36KV Lighting bimpulse 170KV Positive and 180KV Negative,Creepage distance 900mm,Minimum failing load70 KN 371 Earth Wire 7/4 sqmm 372 G.I Flat 50*06 mm 373 33 KV LINE (INCLUDING ALL FOUNDATION WORKS) 374 11 Mtr. Long ST Pole(For new line) ST-410 SP56 375 GI Channel X-arm including clamps and braces 376 100 mm² ACSR DogConductor 377 PG Clamps for 100 mm² ACSR Conductor 378 33kV Polymeric composite Pin Insulator 36kV, 10kN,Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm 379 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm with fittings 380 Galvinized Nuts and Bolts. 381 Danger Plates with Clamps 382 Anti-Climbing Device with Clamps 383 Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. 384 Red Oxide 385 Aluminium Paint 386 Cement bottoming 1:2:4 mix as per REC standards .6cum /pole 387 Stone Pad (300 mm x 300 mmx 75 mm) 388 Aluminium Jointing Sleeves 389 Galvanised Stay Set with 50 x 8 mm stay clamp, guy insulator(2Nos.), anchor plate (300x 300 x 8 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 20 mm diameter solid GS stay rod & 7/4.00 mm dia GI stranded wire complete 390 Guard netting 391 B-ERECTION PART-6.30 MVA DOOL 392 33 KV LINE BAY OF SINGLE BUS SCHEME(INCLUDING ALL FOUNDATION WORKS) 393 33 KVVCB (36 KV, 1250 A, 26.2 KA, outdoor type) 394 33 KV C&R panel along with O/C, E/F relay (IEC 61850) Mimic diagram, voltmeter, ammeter, annunciation windows with annunciation relays, 3 Phase Trivector meter DLMS compliant RS 485 port 395 33 KV Isolatorwith earthing blade(36 KV ,1250A.Outdoor.3 pole,25KA) 396 33 KV Current Transformer (33KV,Single Phase,Multi ratio,multi core ,Outdoor) 1 No per Phase 397 33 KV PT (33KV/110V,1phase,multicore,Outdoor)(1No per phase) 398 30 KV Lightening Arrestor (30KV,10KA,Station Class.ZNO.Polymer) Gapless 399 33 kv Post Insulators polymer type , 36 kv, 235 kv impulse, creepage distance 1224 mm 400 STEEL STRUCTURES/PIPE STRUCTURE(INCLUDING ALL FOUNDATION WORKS) 401 Pipe Nominal bore 200, 5.9 mm thick 402 Galvanised steel structures 403 Galvanized nuts and bolts 404 CONTROL CABLES 405 12 core 2.5 mm2, copper armoured, 1.1 kv grade, ISI FRLS 406 4 core 2.5 mm2copper armoured, 1.1 kv grade, ISI FRLS 407 2 core 2.5 mm2copper armoured, 1.1 kv grade, ISI FRLS 408 Lugs & Ferrules etc. 409 CONDUCTOR AND HARDWARE 410 ACSR Conductor Panther 411 T-Clamp 412 Single Tension fitting 413 PolymerComposit type Disc Insulators.36KV Lighting bimpulse 170KV Positive and 180KV Negative,Creepage distance 900mm,Minimum failing load70 KN 414 Earth Wire 7/4 sqmm 415 G.I Flat 50*6 mm 416 SUB-STATION MAIN EQUIPMENT TRANSFORMER BAY(INCLUDING ALL FOUNDATION WORKS) 417 33 KVVCB (36 KV, 1250 A, 26.2 KA, outdoor type) 418 33 KV Isolatorwithout earthing blade(36 KV ,1250A.Outdoor.3 pole,25KA) 419 33 KV Current Transformer (33KV,Single Phase,Multi ratio,multi core ,Outdoor) 1 No per Phase 420 30 KV Lightening Arrestor (30KV,10KA,Station Class.ZNO.Polymer) Gapless 421 33 KV C&R panel along with O/C, E/F relay (IEC 61850) Mimic diagram, voltmeter, ammeter, annunciation windows with annunciation relays, 3 Phase Trivector meter DLMS compliant RS 485 port 422 33 kv Post Insulators polymer type , 36 kv, 235 kv impulse, creepage distance 1224 mm 423 STEEL STRUCTURES(INCLUDING ALL FOUNDATION WORKS) 424 Pipe Nominal bore 200, 5.9 mm thick 425 Galvanised steel structures 426 Galvanized nuts and bolts 427 CONTROL CABLES 428 12 core 2.5 mm2, copper armoured, 1.1 kv grade, ISI FRLS 429 6 core 2.5 mm2copper armoured, 1.1 kv grade, ISI FRLS 430 2 core 2.5 mm2copper armoured, 1.1 kv grade, ISI FRLS 431 Lugs & Ferrules etc. 432 CONDUCTOR AND HARDWARE(INCLUDING ALL FOUNDATION WORKS) 433 ACSR Conductor Panther 434 T-Clamp 435 G.I Flat 50*6 mm 436 33/11 KV, 6.30 MVA Power Transformer(INCLUDING ALL FOUNDATION WORKS) 437 33/11KV ONAN,6.30MVA Copper wound,Outdoor type,Conventional Power transformer,Oil filled with OLTC and all accessories including HT and LT Terminal connections with busbars 438 12 Core 2.5mmsq Control Cable Copper Armoured,1.1KV Grade .ISI .FRLS 439 6 Core 2.5mmsq Control Cable Copper Armoured,1.1KV Grade .ISI .FRLS 440 2 Core 2.5mmsq Control Cable Copper Armoured,1.1KV Grade .ISI .FRLS 441 Cost for 11 KV Indoor Switchgear of 33/11 kv Substation (Transformer Bay Scheme) 442 11 KV VCB Panel Board ( 12KV,1250A,25KA, Outdoor ) With over current,earth fault relays (IEC 61850),MIMIC diagram,Voltmeter,Ammeter,annuniaciation windows with annunciation relays,Hooter on individual Panels ,3-phase tri vector Smart meter-5A,DLMS Compliant with RS-485 Port(1 Incoming & 4 outgoings ) 443 11KV Gapless Surge Arrestor,9KV,10KA LA With polymer HousingStation Type 444 11KV (UE)XLPE Power Cables (Armoured) 445 11 kV400 mm² 3-Core XLPE Cable (with one spare length) armoured, FRLS 446 11 kV (UE) 3-Core XLPE 120 mm² armoured, FRLS 447 11KVHeat shrink termination Cable Kits (Indoor) 400 mm square (3-core) 448 11KV Heat shrink termination Cable Kits (Outdoor) 400mm square (3-core) 449 11KV Heat shrink termination Cable Kits (Indoor) 120 mm square(one spare) (3-core) 450 11KV Heat shrink terminationCable Kits (Outdoor) 120 mm square (one spare) (3-core) 451 11 KV isolator, double break, 3 pole, 600 Amp. Horizental mounting type with earth switch Complete 452 11KV GO Set, AB switch 3 phase, 3 pole, 400 Amps. 453 100 KVA, 11/.433 KV,Auxiliary Transformer,3 Phase Distribution Transformer with bimetallic terminal connectors ,energy level -2,Al Wound. 454 StT Poles 9 mtrs long 455 Galvanised iron of sorts 456 120 mm2 PVC 4 core cable,Armoured FRLS 457 MCCB 200 Amp 458 Cement bottomng 1:2:4 mix as per REC standards 0.5cum per pole 459 Earthing of 100KVA substation --Excavation ofearth pit of dia650 mm & depth 3000 mm, installation ofEarthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 75 mm x10 mm& 50 mm x 6 mmfor connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. 460 Earthing complete GI pipe 40 mm or GI rod 20mm 2.5 mtr long through G.I Strip 461 COMMON MISCELLANEOUS EQUIPMENTS 462 a) Battery Bank 30 V, 100 AH, of 15 No. cells of 2 V each, sealed maintenance free VRLA type, high impact Polyprophelene copolymer container, flame retardant with stand 463 b) 30 V, 100 AH, float-cum-boost charger with full wave rectification for 220 V, 1 phase, 50 HZ AC input supply. 464 Distribution panel (30V, DC) made of CRCA thickness not less than 2 mm ,Powder coated degree of protection IP 43 for two number battery incoming supplywith 2No. 63 Amp. DP MCB for incoming supplydouble bus bar of adequate size,twelve number DP DC MCB(0-32A) including indication lamp and cables and other accessories 465 Distribution panel (415 V, AC)made of CRCA thickness not less than 2 mm ,Powder coated degree of protection IP 43 200A Switch fuse disconnector for incoming supply and five numbers TPN MCBs(16-125A) and five number DP MCB(0-32A),rectangular bus bar suitable for 200 A continous supply including indication lamp cables and other accessories. 466 Telecommunication facilities including cctvs set (4nos cameras ) LED Display (32) 467 CIVIL WORKS 468 Compound walling of identified land by way of Mass Concrete in Foundation and 228mm bricks of 2M height 469 Chain-link Fencing of 33kv Yard of Substation by way of Mass Concrete in Foundations and chain-link fencing of 6 ft height. 470 33/11kv power Transformer Foundation 471 33kv Equipment Foundation and gantry foundation 472 Earthing Mat complete job GI flat 50x8 mm 473 Earthing electrode ( 3 meters long, 40 mm dia GI pipe) through GI strips 474 33kv Yard Concreting / Metalling 475 Underground Water tank 10000 Ltrs. 476 Overhead water tank 2000Ltr 477 Control room Building including wash room ,pantry room .sanitary fittings tile works ,kota stone in control roominternal wiring,painting and fixing of electrical appliances like lights ,fans,geysers job complete finish 478 Shift Quarters for Je and SBA including wash room ,pantry room .sanitary fittings tile works ,kota stone in control roominternal wiring,painting and fixing of electrical appliances like lights ,fans,geysers job complete finish 479 Truss for control room building 1.3xPlinth area .Providing and fixing of Steel Truss including provision for colur coated Roofing 158 sqm 480 Development of identified land by way of removing weeds, wild grass and undulation if any, ornamental land scraping and growing of ornamental trees in un built areas and road sides and development of road along with surface drain. 481 Construction of semi Pucca B/Wall of 2.0 Mtr. Height (Length=100 mtr) 482 Dry random rubble masonry with hard stone in foundation and plinth: Without bond stone 483 Construction of Pucca Drain 484 Yard Lighting ( 6 Nos yard and 02 Nos CR back side) on 9m Long Poles 485 ERECTION OF 33 KV LINEDOOL(INCLUDING ALL FOUNDATION WORKS) 486 11 Mtr. Long ST Pole(For new line) ST-410 SP56 487 GI Channel X-arm including clamps and braces 488 100 mm² ACSR DogConductor 489 PG Clamps for 100 mm² ACSR Conductor 490 33kV Polymeric composite Pin Insulator 36kV, 10kN,Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm 491 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm with fittings 492 Galvinized Nuts and Bolts. 493 Danger Plates with Clamps 494 Anti-Climbing Device with Clamps 495 Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. 496 Red Oxide 497 Aluminium Paint 498 Cement bottoming 1:2:4 mix as per REC standards .6cum /pole 499 Stone Pad (300 mm x 300 mmx 75 mm) 500 Aluminium Jointing Sleeves 501 Galvanised Stay Set with 50 x 8 mm stay clamp, guy insulator(2Nos.), anchor plate (300x 300 x 8 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 20 mm diameter solid GS stay rod & 7/4.00 mm dia GI stranded wire complete 502 Guard netting 503 SAFETY ITEMS FOR HASTI AND DOOL RECEIVING STRATIONS 504 Rubber Mat 1m*2m (19mm thick) 505 Fire Extinguisher CO2 type of 4.5 Kg capacity for control room 506 3-Sand Bucket Fire Extinguisher 507 Helmet 508 Rubber Gloves for 33 KV Level 509 Rubber Gloves for 11 KV Level 510 SafetyBelt 511 Safety Shoes 512 Earthing rod (set of 3 rods) 513 HV Detector all Voltages 514 Multimeter 515 C-SPARE ITEMS (TO BE SUPPLIED TO DIVISIONAL STORES ) 516 Aluminium Ladder Sliding type 30 feet Long 517 Lifting and Puling machine 5 Ton 518 Come along Ratchet Upto Wolf Conductor 519 33kV Polymeric composite Pin Insulator 36kV, 10kN,Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm 520 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm 521 Meggar 5KV (Reputed make ) 522 Digital earth tester as per relevant standards (Inspection shall be carried out by the representative of this Divisionbefore supplying )
Contract Date : Ref. Documents   |   Contract Value : Ref. Documents
BRR : 3276194 Selection Of Event Management Agency For Erecting Hangars, Octonorm Stalls Including Other Ancillary Services On Rental Basis For Mahalaxmi Saras Exhibition -2023-24-2 Waterproof Aluminum German Hanger For Exhibition Area With Fire Retardant Top Covering, Side Covers, Front Facade Etc. All The Structures / Hangars Should Be High Quality German Technology Aluminium Structure With Wooden Platform Of 6 “Height. 3 Proper Tin 8 Feet High With Covering White Cloth / Barricading Of Entire Area For Safety Purpose With Provision Of Appropriate Brandings Of The Event. 4 Adequate General Led Lighting Inside The Hanger Of 9000Sq. Mtr Area ( Natural White Led Light ) 5 Construction Of Approx. 441 Nos. Well-Designed Exhibition Octonorm Stalls ( 100 Nos.-Size 2X2m, & 341 Nos.-3X2 M. ) Outdoor Stalls To Be Provided With Wooden Platform ( Construction Of Stalls With Aluminum R8 System With Powder Coated Finish With Laminated Panels & Fascia Having Name For State And Stall Number With Cut Out Letters ) . Accessories For Each Stall:A. Wooden / Glass Shelves / Racks As Per Requirement With Proper Clamps, Etc. B. Power Socket 5 And 15 Amp. C. Waste Paper Basket With Bio-Degradable Garbage Bags 6 Octo Norm 1 Tables In Each Stall ( Construction Of Table With Aluminum R8system With Powder Coated Finish With Board On Top ) 7 Good Quality Banquet 2 Chairs In Each Stall 8 2 Led Spot Lights In Each Stall With Proper Hooks And Wiring 9 Providing Ceiling Fans Inside The Hangar As Per The Requirement 10 B. Stage Setup 11 Stage Setup : 40 Ft. X 32 Ft. X 4.00 Ft. High Ms Structure With Scaffolding / Truss Blocks With Ply Board On Top & Following Items :A. Steps On Both Side 8 Ft. Wide With Railing And Masking B. Arrangement Of Floral Belt In Front Of Stage With Decoration With Flowers With Led Plasma 12 Double Seater Sofa 13 Single Seater Sofa 14 Centre Table 15 Good Quality Banquet Chairs 16 Podium With Branding 17 Led Riser 40 Ft. X 4 Ft. X 10 Ft. With Masking & Carpet From All Sides 18 Green Rooms With Wooden Platform With Proper Lighting And Other Required Items Like Adequate Mirror / Cloth Stand / Spot Lights / Power Points / Tables / Chairs And All Other Furniture Required Of Approx. 250 Sq. Ft. Each 19 Platform For Media Setup With Carpet, Masking From All Sides And Required Furniture With Necessary Fixtures & Lighting Of Size 8 Ft. X 6 Ft. X 4 Ft. 20 Platform For Light & Sound Console With Carpet, Masking From All Sides Including Required Furniture, Etc. With Necessary Fixtures & Lighting Of Size 24 Ft. X 6 Ft. X 4 Ft. 21 C. Sound Items ( Reputed Brand 3 Way Sound System ( Jbl Vertec / Rcf Ttl Series Or Equivalent ) 22 Platform For Camera Setup With Carpet, Masking From All Sides Including Required Furnitures, Etc. With Necessary Fixtures & Lighting Of Size 8 Ft. X6 Ft. X4 Ft. 23 Pa Top Line Array 24 Delay Speakers / Top With Stands 25 Pa Side Fills 26 Pa Front Fills 27 Pa Bass B 28 Stage Monitor 29 Digital Mixer 64 Channel B 30 Amp / Cabling / Racks 31 Artist Tech Rider 32 Power Amplifiers & Crossover ( As Per Requirement ) 33 Di Box ( As Per Requirement ) 34 Cordless Microphone With Similar Configuration As That Of Shure / Sennheiser 35 Central Pa Sound System For Entire Venue And Parking With Suitable Sound Outreach At All Places 36 Sound Technician 37 D. Lights Items 38 Box Truss For Lights Of 20 Ft. Height With Proper Base And Support 39 P3 Led Wall 40 Ft. X 10 Ft. For Stage Backdrop With Technician And Operator Support For Entire Period Of Exhibition. 40 High Resolution Led Screens Inside And Outside Hangar Structure For The General Public To Show The Schemes And Programs Of The Ministry With Technician And Operator Support For The Led Screen. 16 X12 Feet - 2 Nos. 41 Platform For High Resolution Screen With Masking ( I ) 10 X 4 Feet -2 Nos 42 Beams Sharpy Beam 200 43 Profile Lights 44 Led Par 32 45 Led Par 64 46 Led Beam Par 47 4 Way Mollify 48 Dimmer Pack ( As Per Requirement ) 49 Avolite Pearl For Controlling The Light Set Up ( As Per Requirement ) 50 E. Video & Photography 51 Video Coverage Of Inaugural Function & All Other Major Events / Function During The Fair And Video Coverage Of Stalls ( 04 Copies Of Dvds Must Be Provided To With Proper Mixing And Editing In Addition To Source Media ) . Live Video Coverage Of The Cultural Events And Inaugural Function In The Led Panel. 52 Still Photography Coverage ( 1000 Selected Photos In Size 5X7 Inch With 2Numbers Of Albumsin Addition To All The Photographs In Digital Format Must Be Provided . [ Photographer Should Be Available With Hd Camera In The Entire Period Of Fair At Event Site ] . 53 Seamless Switcher 54 F. Manpower 55 Attendant / Facilitators ( Male &Female ) Well Experienced Duly Uniformed As Per Our Requirement 56 Mts ( Multi-Tasking Staff ) For Managing Registration Counter & Other Areas Of Exhibition 57 Charges For Sanitation / Cleaning Workers For Cleaning Materials Wearing Caps And T-Shirts With Printed Logo Of Swatch Bharat Abhiyan 58 Charges For Sanitation / Cleaning Supervisor For Cleaning Materials Wearing Caps And T-Shirts With Printed Logo Of Swatch Bharat Abhiyan. 59 T- Shirts For Staff 60 G. Vip Lounge 61 Construction Of Well-Designed One Air Conditioned ( With Tower Ac ) Vvip Room With Proper Wooden Platform, Flooring, Carpeting And False Ceiling , Lights Etc. Rates Including Flower Decoration ( Every Day ) , Fridge, Crockery For Minimum 20 Persons / Fancy Cushion Chairs / Two And Three Seater Sofas, Center Tables, Coffee Tables And Other Required Items For Beautification Of The Room. 62 Construction Of Well-Designed One Air Conditioned ( With Tower Ac ) Vip Room With Proper Wooden Platform, Flooring, Carpeting And False Ceiling , Lights Etc. Rates Including Flower Decoration ( Every Day ) , Fridge, Crockery For Minimum 20 Persons / Fancy Cushion Chairs / Two And Three Seater Sofas, Center Tables, Coffee Tables And Other Required Items For Beautification Of The Room. 63 Construction Of Well-Designed One Air Conditioned ( With Tower Ac ) Room With Proper Wooden Platform, Flooring, Carpeting And False Ceiling , Lights Etc. Rates Including Flower Decoration ( Every Day ) , Fridge, Crockery For Minimum 10 Persons / Fancy Cushion Chairs / Two And Three Seater Sofas, Center Tables, Coffee Tables And Other Required Items For Beautification Of The Room. 64 H. Conference Room 65 Construction Of Well-Designed Air Conditioned ( With Tower Ac ) Conference Room Cum State Coordinator Room / Meeting Room With Wooden Structure / Platform / Flooring / False Ceiling And Proper Carpeting And Proper Lighting. Conference Table / B2b Area With Sufficient Number Of Chairs And Other Required Furnitures Like Sofa / Coffee Table / Side Tables Etc. Interior Of The Room Should Be Well Thematic Decoration For Seating Arrangement Of 100 Persons. 66 Sound System For Conference / Meeting Room With02 Cordless Handheld Mic, Goose Neck Talk Back System Mic, Amplifier, Speakers Suitable Along With Technician 67 I. Theme Area 68 Designing And Conceptualization Of Well-Designed Theme Area With Proper Display, Lighting, Logos, Graphics And Artwork Complete With Raised Platform, Designer Wooden Flooring, Reception And Required Furnitures. Led Screen - 2 Nos ( Size 42 Inch ) , Wooden Digital Poster And Other Par Can / Fancy Lights With Colorful Decoration. Photo Gallery Of Shg Products. 69 J. Food Court -J1- Food Court Area - Pavilion Setup 70 Weather Proof Pandal For Setting Up Kitchen Pot Wash Area, Require A Roof Cover To Be Installed, 15 Ft. Height To The Backside Of The Kitchen Work Area For Washing Big Utensils And For Resting Purpose. 71 Setting Up 8 Individual Stalls ( As Per Drawing / Layout ) Inside The Main Pandal ( German Hanger ) As Per Direction Of Food Court Management Committee. Stall Will Be Cover With All Side Along With Door With Lock Facility. Each Stall Having Minimum Area And Requirement: • One Administrative Office With Power Plug With 3 Pins - 5M X 5M., Should Be Furnished With 1 Table And 5 Numbers Of Chairs ( Armless ) , Should Be Electrified With Power Plug With 3 Pins, 1 Numbers Of Fluorescent Tube, 1 P.C. & 1 Printer With Internet Facility. • One Finance Room - 5M X 5M, Should Be Furnished With 1 Table And 5 Numbers Of Chairs ( Armless ) , Should Be Electrified With Power Plug With 3 Pins, 1 Numbers Of Fluorescent Tube, 1, P.C. & 1 Printer With Internet Facility Having Internet Speed Up To 100 Mbps Or As Required. • One Infant Feeding Room With Power Plug With 3 Pins - 3M X 3M, Should Be Furnished With 1 Table And 10 Numbers Of Chairs ( Armless ) , Should Be Electrified With Power Plug With 3 Pins, 1 Numbers Of Fluorescent Tube 72 Setting Up 70 Individual Stalls Inside The Main Pandal As Per Direction Of Food Court Management Committee Of Jute Frame ( Dyed Jute ) With Adequate Support System Of Bamboo ( 10 Ft. Height ) Of Below Mentioned Size: 3 M X 3 M - 70 Nos With The Table On 3 Sides With The Proper Cover ( 3 Table + 2 Chairs ) 73 Straight Panel Behind The Food Stalls 74 Almirah With Safe Locker Facility– 2 Numbers ( For Admin And Finance Room ) 75 Foldable Square Tables For Kitchen Area. 76 Round Dining Tables With Cloths Cover Over The Tables In Dining Area ( 4 Ft. Radius ) 77 Standing Tables ( Standard Size ) 78 Chairs Without Arms For Dining Area. 79 Chairs ( Armless ) In Each Stall For 70 Food Stalls 80 K- Plumbing And Water Arrangement 81 Syntex Water Tanks With A Total Capacity Of 30000 Liters With Motor And Necessary Plumbing Arrangements At Ground Level Near The Raised Syntex Tank For Continuous Water Supplyto The Kitchen / Food Court And Wherever Necessary With Adequate Backup Other Than 30, 000 Liters 82 Plumbing Lines Of 25 Mm Pvc Pipes To Kitchen, Food Court, Etc. ( As Required As Per Direction Of Food Court Management Committee ) 83 Kitchen Sinks ( 2Ft X 2 Ft. ) With Water Taps With Necessary Plumbing And Drainage Arrangements. 84 Supplying With Pot Wash Area Sink With Water Taps With Necessary Plumbing And Drainage Arrangements ( Sink Specification - 3Ft X 3 Ft. ) 85 Hand Wash Basins Of 5 Numbers On Strong Stands And Providing The Same With Continuous Water Supply For Washing And Necessary Drainage Of The Used Water 86 Grease Filters 87 L- Electrical And Electronic Arrangements 88 Hire And Labor Charges For Providing And Fixing Exhaust Fans In Cooking Area As Per Is Specifications With Suitable And Safe Wiring 89 15A Power Sockets ( With 3 Pins ) Giving Connection With Safe Wiring And Insulation As Per Is Standards And Specifications As Required In Food Stalls And Kitchen Area 90 M. Kitchen Vessels And Cooking Equipments 91 Providing Domestic Stove ( 2 Burner ) ( As Per Direction Of Food Court Management Committee ) 92 Erecting And Providing Gas Pipe Line And Connection As Per Directions And Specifications M / S Mahanagar Gas Ltd 93 Provide Deep Freezer ( 300 Ltr ) With Power Supply ( As Required As Per Direction Of Food Court Management Committee ) ( Vertical -5 Nos. + Deep -5 Nos. ) 94 N. Waste Management 95 Kitchen Area Providing Waste Bin For Food Waste ( Green ) - 20 Waste Bins With 100 Ltrs Capacity Waste Bins For Plastic Waste ( Red ) – 10 Waste Bins With 50 Ltrs Capacity Waste Bin For Paper Waste ( Yellow ) - 10 Waste Bins With 50 Ltrs Capacity 96 Dining Area- Providing Waste Bin For Food Waste ( Green ) - 20 Waste Bins With 100 Ltrs Capacity Waste Bins For Plastic Waste ( Red ) – 20 Waste Bins With 100 Ltrs Capacity Waste Bin For Paper Waste ( Yellow ) - 20 Waste Bins With 100 Ltrs Capacity 97 Providing Bio-Degradable Garbage Bags ( One Packets Having 50 Pieces ) 98 Garbage Cleaning & Collection Van ( 2 Times A Day ) With Manpower For The Entire Period Of The Show. Waste Disposal Should Be Done As Per The Municipality Norms By The Contractor 99 O. Human Resource / Manpower Requirement 100 Charges For Sanitation / Cleaning Workers For 15 Days With Cleaning Materials 101 Q. Toilets 102 Portable Chemical Toilets ( Each Separate For Ladies And Gents ) With Proper Staff. Facility Should Be Provided One Day Before The Event. 103 Adequate Cleaning And Sanitizer Material For Toilets, Hand Wash, Paper Napkin, Cented Phenyls, Odonils Etc. For The Entire Exhibition Period. 104 R.Electricals & Gensets 105 Power Distribution With Armored Cables From Main Panel Board & Generator Up To Exhibition Hall / Stage / All Hangers / Food Area And All Over The Ground & Sub Distribution With Main Panel Switch Board & Sub Main Panel Board. 1500 Kw 106 Lighting Poles With Proper Wiring / Earthing For Entire Venue With Adequate Number Of Poles Should Be Provided. 107 Metal / Flood Lights For All Over The Venue 108 Electrical Cabling Of Entire Venue With Proper Covering 109 Ground Earthling Through The Area For Generator And Lighting 110 Cabling & Changeover Box / Main Panel With Proper Fittings 111 S. Branding And Printing 112 Branding Of The Entire Venue Including, Hangar Facades & Side Covering Of The Hanger Structures, Stage Side Panels, Standee, Pole Buntings, Welcome Hoardings, Signages Etc. Vinyl Flex Print. ( Block Out Flex ) , Large Display Of The Layout Of Stalls. 113 Construction Of Theme Based Flood Lit Gates Based On Theme Main Entrance & Hangar Entry / Exit ( Artistic Design, Decoration ) 114 Mdf With Paint Finish 3D Block Letters Of #Mahalaxmi Saras ( 2.5 X 20 Ft. ) With Platform 2 Ft. Height 115 Id Cards With Lanyards With Hologram 116 T. Security, Cctv & Fire Services 117 Security Guards Male-20, Female-10 ( 9.00 A.M. To 9.00 P.M. 118 Security Supervisor Male-2, Female-1 ( ( 9.00 A.M. To 9.00 P.M. ) 119 Security Guards Male-15 ( 9.00 P.M. To 9.00 A.M. ) 120 Security Supervisor Male-4 ( 9.00 P.M. To 9.00 A.M. ) 121 Dfmd Machines With Staff With Auto Entry Counting Facility 122 Hhmd Machine With Staff 123 Providing Of Fire Extinguishers In Exhibition Area Abc Type Cylinders With Sand Buckets ( Co2 Water And Powder Mix With Refilling Dates ) . Sufficient Equipment To Be Placed At Various Locations As Per Directions Of Fire Department. 124 Cctv Cameras Set Up All Over The Venue, Cameras Shall Have Night Vision With Operator & Technician 125 Lcd Monitors For Ccctv Camera 126 Recording Dvr 127 Construction Of Room With Octonorm ( 3 M X 3 M ) In Each Hangar For Monitoring Of Cctv Cameras Etc. With Chair, Table, Operator & Technician Near Police Control Room 128 Frisking Area At Entry Points ( 4 M X 4 M ) 129 Emergency Exit Gate Without Branding 130 U.Registration & Help Desk 131 Construction Of Registration Desk Of ( 10 X 5 ) Meter Well-Designed Structure With Adequate Lighting, Platform, Carpet, Counter, Brochure Stand & Banquet Chair& One Steel Almirah With Lock Facility. 132 3 X 3M German Pagoda For Help Desk, Police Control, First Aid, Lost & Found Etc. With Coveredfrom All Sides And Tophaving Wooden Platform, Carpet, Adequate Lighting & Basic Furniture ( Pagoda With Aluminium Structure With Waterproof And Fireproof Retardant Sheet Should Be Strong Enough To Sustain High-Speed Wind / Rain Pressure ) 133 V.First Aid Facilities ( Medical Facilities ) 134 Construction Of A First Aid Room 6 M X 3Mwith All Required Facilities Curtains / Divider In German Pagoda 135 W.Others 136 Construction Of Store Room ( 5 M X 5 M ) Aluminium R8system With Powder Coated Finish With Laminated Panels, Carpet, Lighting & Basic Furniture 137 Construction Of Housekeeping Room ( 3 M X 3 M ) Aluminium R8 System With Powder Coated Finish With Laminated Panels, Carpet, Lighting & Basic Furniture 138 Construction Of Fire Service Room ( 3 M X 3 M ) Aluminium R8 System With Powder Coated Finish With Laminated Panels, Carpet, Lighting & Basic Furniture 139 Construction Of Security Room ( 3 M X 3 M ) Aluminium R8 System With Powder Coated Finish With Laminated Panels, Carpet, Lighting & Basic Furniture 140 Carpeting - Non Woven Needle Punch Laying & Fixing Of Brand New Carpet Subject To Actual Requirement And As Per The Direction Of Core Committee. 141 Coir Type Carpet For Outdoor & Other Required Area 142 Drinking Water Tanker For Cooking Purpose ( 10000 Ltr Tanker Capacity ) Or As Per Direction Of Food Management Committee 143 Green Agro Net For Passage Area 144 Landscaping With Good Quality Natural Potted Plants In Entire Exhibition Area 145 Proper Ground Levelling Of Main Exhibition Ground As Well As Parking Ground With Road Roller And Jcb ( Refer Site Layout Plan )
Contract Date : 23 Dec, 2023   |   Contract Value : 3.55 Crore
Disclaimer

We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.

Tender Detail
Website https://tender.nprocure.com/
Quantity
MSME Exemption No
Tender Type Open Tender
Startup Exemption Click Here
Competitive Bidding NCB
Similar Tenders
TENDER INSIGHTS

858

Electric Tenders
Live
CLICK TO KNOW MAXIMUM WIN

Tell us about your Product / Services,

We will Find Tenders for you

🇮🇳 +91
TenderDetail
Loading tenders