TDR : 57006846
prasar bharati

Tender Brief :

Kolkata, West Bengal

Tender For Renovation Of Electrical Works For Akashvani Bhawan, Kolkata.(Sh:-Replacement Of Old Industrial Panel With Cubical Type Lt Panel, Wiring/Re-Wiring With Modular Switch & Socket Of Ground Floor Technical Area, Replacement Of Fans, Fitting, Mcb Db

Published: 14 Aug 2026
Opening: 24 Aug 2026
Closing: 24 Aug 2026
Amount: 32.04 Lakhs
EMD: 64088
Tender Fee: Ref. Documents


Works Active Harmonic Filter Actuator Aerial Cable Aerodrome Beacon Air Circuit Breaker
9
Days Left
Tender Summary / Eligibility Criteria
Tender For Renovation Of Electrical Works For Akashvani Bhawan, Kolkata.(Sh:-Replacement Of Old Industrial Panel With Cubical Type Lt Panel, Wiring/Re-Wiring With Modular Switch & Socket Of Ground Floor Technical Area, Replacement Of Fans, Fitting, Mcb Db, McbS Including Service Connection Cable).
Documents Download All
ac17ff54-bf8f-4ba9-82f0-bcb4d1dc8c46
ac17ff54-bf8f-4ba9-82f0-bcb4d1dc8c46.pdf
No Boq
No Corrigendum
Probable Bidders

AI engine predicts probable bidders to help you bid strategically.

MSME Exception
Explore More →
Technical
Tender involves procurement of high capacity electrical equipment including diaphragm coupling of pump & motor with 90kW capacity at 2900 RPM. The project scope includes installation, testing, commissioning and operational handover.
Previous / Similar Result
BRR : 7989591 Annual Maintenance contract for Electrical Maintenance of the entire building of Commercial Tax building from ground floor to 10th floor with supply and delivery consumable materials for day to day maintenance and servicingat the Northern Block ofJalasampad Bhawan, Salt Lake, Kolkata : 91, during the year 2025-26 (w.e.f. 01.07.2025 to 31.03.2026)- Sub-Head-I(Day to Day maintenance with labour)Engagement of personnel for Electrical maintenance work at lift room and panel board comprising the maintenance of floor panel board , P.B.D.B, B.D.Bs tube light fittings, ceiling fans and call bellincluding earthing making addition and alteration and changing of electrical equipments which will be supplied by departmentally as per direction of EIC[01(one) no. electrician and 02 (two) nos. Helper will be engaged for each working day](Contractor should arrange his own tools and tackles for the job. Labour rates are inclusive of GST, Cess, ESI, EPF, Bonus, CP & OH T & P charges) 2 1 No Electrician/ day x 1 shift/ day x 196 days throughout the period from 01.07.2025 to 31.03.2026 excluding Saturdays, Sundays & holidays) 3 2 Nos Helper for Electrician/ day x 1 shift/ day x 196 days throughout the period from 01.07.2025 to 31.03.2026 excluding Saturdays, Sundays & holidays) 4 Sub-Head-II Supply of EI materialsSupply and delivery of different electrical materials for the electrical maintenance at Commercial Tax Building. 5 Supply TMC501 Conventional industrial batten Philips LEDtube, model no : TMC 501 P 1xT-LED 22W P3241 with 1no Mas LEDtube 1200mm 18W865 T8 I – 2100lm including necessary connection. 6 Supply Philips LED tube, model no: Mas LED tube 1200mm 18W865T8 I – 2100lm 7 Supply of PhilipsGreenLED Ultima Square 6 x 6 , Type-DN097B LED10S-6500 PSU WH, 10Watt, Make : Phillips 8 Philips LED Driver for TMC 501 LED Tube light sets 9 Supply of Tube Light (40 W, 4 ft), Make-Philips 10 36/40W, 230V fluorescent copper choke (Type-TDL 36W/TL40W/ Euivalent) (Philips make) 11 Supply of Tube Light Starter(40W/36W,4ft(Philips 12 Anchor Grip PVC Tape (1.80 cm X 7.5M) MAKE : Anchor Panasonic 13 Supplying following sizes Capacitor of 250V rating: 14 2.5 MFD Capacitor (Universal Make or equivalent) 15 4 MFD Capacitor (Universal Make or equivalent 16 Supplying of following wires:- 17 1.5 sq.mm FR stranded Copper Wire 18 2.5 sq.mm FR stranded Copper Wire 19 4.0 sq.mm FR stranded Copper Wire 20 Supplying of following various lights, switches, starter etc. 21 Single phase motor starter C 12MO1H 11.00A - 18.00Afor 2.00 Ton AC, make-North West or equivalent. 22 Supplying of different types of LED lamps (12W), make- Philips,12Watt, Base B22/E27, 1200LM, 23 20A Combined power plug, switch and fuse unit (Make - Anchor) with box 24 Supplyof Tube light holder forNormal & T5tube light, Type: T5 Push Fit Holder Shape (Vertical). 25 6A piano key type switch. 26 5A,3 pinpiano flush type socket. 27 20A Piano key type Switch. 28 15A,3 pinpiano flush type socket. 29 6A Modular type Switch 30 16A Modular type Switch 31 6A Modular type 5 pin Plug Socket 32 16A Modular type 6 pin Plug Socket 33 Step type electronics Fan regulator, Make- Anchor or eqivalent. 34 25A, 250V, 3 pin Modular type power socket (Make- North West) or equivalent 35 Double pole DP MCB C Curve,6 Amp - 32 Amp,Make- L & T10A - 10 Nos.25A - 10 Nos32A - 10 Nos. 36 Double pole DP MCB C Curve,40 Amp - 63 Amp,Make- L & T40A - 5 Nos.63A - 5 Nos 37 Single pole SP MCB C Curve,6Amp-32Amp,Make- L & T.6A - 15 nos10A - 15 Nos.25A - 15 Nos32A - 15 Nos 38 Double pole Isolator,40Amp,Make- L & T. 39 Double pole Isolator,63Amp,Make- L & T. 40 Fourpole Isolator 80Amp,Make- L & T. 41 Fourpole Isolator 100Amp,Make- L & T. 42 20A Combined power plug switch and fuse unit (Make- Anchor) with box. 43 Supplying of 4 x 7 PVC surface Box 44 20mm dia PVC Conduit pipe 45 25mm dia PVC Conduit pipe 46 Ding Dong Call Bell (make-Anchor penta) 47 Supply of 6A 3 Pin plug top code- 38626/3982, Make -Anchor. 48 Supply of 16A 3 Pin plug top code- 38626/3982, Make -Anchor. 49 Supply of 25A 3 Pin plug top code- 38626/3982, Make -Anchor. 50 Supply csk/pan slotted self taping screw 51 3x13mm 52 3x25mm 53 3x19mm 54 Supplying of different sizes GI modular switch boxes of following sizes, make : Anchor or equivalent 55 2 module GI box, 56 4 module GI box, 57 6 module GI box, 58 2 row 12 module GI box 59 Supplying of approved make high speed ceiling fan (ISI marked) of following sizes having double ball bearing complete with standard down rod, canopy, hanging shackle, Aluminium blades, without regulator, A.C. 230-250 volts 60 900mm/ 1050mm/ 1200mm 61 Supplying of approved make Pedestal fan oscillating type with base,blades, guard, speed regulator etc. AC 230-250 volts. 62 450mm sweep 63 Supplying of approved make wall fan oscillating type with base, blades,guard, speed regulator etc. AC 230- 250 volts. 64 400mm sweep 65 Supplying of approved make exhaust fan heavy duty with mounting frame,blades AC 230-250. 66 225mm sweep RPM 900 / 1400 (9) 67 Anchor make spike guard, HSN: 8536, code: 22048, four universal socket with single switch, cable length: 4.0 Mtr
Contract Date : 01 Jul, 2025   |   Contract Value : 8.31 Lakhs
BRR : 8313816 Tender For Supply, installation, testing & commissioning Of Silent Dg Sets Of Different Capacity With Amf Panel Including Exhaust Pipe Line And Necessary Ei Work Against Different Important Buildings In The Premises Of Ipgmer - Sskm Hospital --------- S And D Of Dg Set For Upcoming Loads (Electrical Installation Work) Sl. No. Item Description 1 Dismantling of old damaged/derated LT cables/ defung feeder pillar box/panel/DB etc after necessary electrical testing & disconnectingthe all incoming & outgoing cables carefully and making temporary connection as per direction of the E.I.C. ( different locations of SSKM Hospital under jurisdiction of AE/SSKMHESD/P.W.Dte.). 2 Replacement of Panel :- 3 EXTENSION OF RAW PANEL AT SUB STATION - I : SITC offloor mounted Indoor type extensible cubical typeLT Panel,fabricated by CPRI approved panel makeras per size,design & drawing to be approved by EIC and conforming to relevant ISwith latest modification and as per detail specification and approve make attached ( uploaded in the specification section)[I/C-1 1600A4P ACB - 1 No. and I/C-2 & B/C - 1250A 4P ACB - 2 Nos. incl Mechanical & Electrical Interlock, BBC 2500A 4 Bars- 1 Sets & Modification of existing bus bar,O/G : 800 A 4P MCCB --- 04 nos, 630 A 4P MCCB --- 04 nos [ Make : ABB / Schneider / Legrand / Siemens / LK]. 4 SUB PANEL AT SUB STATION - VI : SITCof floor mounted Indoor type extensible cubical typeLT Panel,fabricated by CPRI approved panel makeras per size,design & drawing to be approved by EIC and conforming to relevant ISwith latest modification and as per detail specification and approve make attached ( uploaded in the specification section)[I/C 1250A 4P ACB - 01 No. BBC 2000A 4 Bars- 1 Sets,O/G : 800 A 4P MCCB --- 03 nos, 630 A 4P MCCB --- 03 nos [ Make : ABB / Schneider / Legrand / Siemens / LK]. 5 RAW PANEL AT SUB STATION - II : SITCof floor mounted Indoor type extensible cubical typeLT Panel,fabricated by CPRI approved panel makeras per size,design & drawing to be approved by EIC and conforming to relevant ISwith latest modification and as per detail specification and approve make attached ( uploaded in the specification section)[I/C 1000A 4P ACB - 01 No. BBC 1600A 4 Bars- 01 Sets,O/G : 800 A 4P MCCB --- 02 nos, 630 A 4P MCCB ---- 04 Nos.,400A 4P MCCB --- 01 Nos. & 250A 4P MCCB - 01 Nos ] [ Make : ABB / Schneider / Legrand / Siemens / LK]. 6 SUB PANEL AT EASTERN & WESTERN SIDE OF UCM BUILDING :- SITCof floor mounted Indoor type extensible cubical typeLT Panel,fabricated by CPRI approved panel makeras per size,design & drawing to be approved by EIC and conforming to relevant ISwith latest modification and as per detail specification and approve make attached ( uploaded in the specification section)[I/C 630A 4P MCCB - 02 No. BBC 1000A 4 Bars- 01 Sets,O/G : 125A 4P MCCB --- 06 Nos. & 100A 4P MCCB - 04 Nos ] [ Make : ABB / Schneider / Legrand / Siemens / LK]. 7 SUB PANEL ATWESTERN SIDE (MCI) OF UCM BUILDING :-SITCof floor mounted Indoor type extensible cubical typeLT Panel,fabricated by CPRI approved panel makeras per size,design & drawing to be approved by EIC and conforming to relevant ISwith latest modification and as per detail specification and approve make attached ( uploaded in the specification section)[I/C 800A 4P MCCB - 02 No. BBC 1250A 4 Bars- 01 Sets,O/G : 400A 4P MCCB --- 02 Nos, 250A 4P MCCB --- 03 Nos. & 100-125A 4P MCCB - 04 Nos ] [ Make : ABB / Schneider / Legrand / Siemens / LK]. 8 SUB PANEL FOR PUMP & BSNL TOWER AT TRAUMA CARE CENTRE :-SITCof floor mounted Indoor type extensible cubical typeLT Panel,fabricated by CPRI approved panel makeras per size,design & drawing to be approved by EIC and conforming to relevant ISwith latest modification and as per detail specification and approve make attached ( uploaded in the specification section)[I/C 400A 4P MCCB - 02 No. BBC 640A 4 Bars- 01 Sets,O/G :100-125A 4P MCCB - 06 Nos &Fully Automatic Star Delta Stater - 04 Nos ] [ Make : ABB / Schneider / Legrand / Siemens / LK]. 9 PILLAR BOX AT ACADEMIC & EMERGENCY BUILDING :- SITCof floor mounted Indoor type cubical typeLTFeeder Pillar Box,fabricated by CPRI approved panel makeras per size,design & drawing to be approved by EIC and conforming to relevant ISwith latest modification and as per detail specification and approve make attached ( uploaded in the specification section)[I/C 800A 4P MCCB - 01 No. BBC 1280A 4 Bars- 01 Sets,O/G : 400A 4P MCCB --- 04 Nos, 200A 4P MCCB --- 02 Nos.][ Make : ABB / Schneider / Legrand / Siemens / LK]. 10 PILLAR BOX AT RONALD ROSS & CARDIOLOGY BUILDING :-SITCof floor mounted Indoor type cubical typeLTFeeder Pillar Box,fabricated by CPRI approved panel makeras per size,design & drawing to be approved by EIC and conforming to relevant ISwith latest modification and as per detail specification and approve make attached ( uploaded in the specification section)[I/C 800A 4P MCCB - 02 No. BBC 1280A 4 Bars- 01 Sets,O/G : 160A 4P MCCB --- 02 Nos, 125A 4P MCCB --- 04 Nos. & 100A 4P MCCB - 04 Nos ] [ Make : ABB / Schneider / Legrand / Siemens / LK]. 11 PILLAR BOXFOR PUMP IN FRONT OF RMO QUATER : SITCof floor mounted Indoor type cubical typeLTFeeder Pillar Box,fabricated by CPRI approved panel makeras per size,design & drawing to be approved by EIC and conforming to relevant ISwith latest modification and as per detail specification and approve make attached ( uploaded in the specification section)[I/C 160A 4P MCCB - 01 No. BBC 250A 4 Bars- 01 Sets,O/G : 100/125A 4P MCCB --- 04 Nos. & Fully Automatic Star Delta Stater - 04 Nos ] [ Legrand / LK ] 12 Repairing of existing feeder Piller box by S&F of 3mm MS sheet including fabrication, S&F of door hinges and loocking arrangement. The Piller Box shouled be painted by approved paint after two coats of redoxide primar as per direction of EIC.(Back Side of Carmical Hostel). 13 Repairing of existing feeder Piller box if required includinge painting by approved paint after two coats of redoxide primar as per direction of EIC.(at different side). 14 S&F of following capacity 415V, 4-pole on-load changeover switch front hanle in SS enclosure with both side cable end box of suitable size on MS angle iron frame on wall (Make:-Legrand / LK/ Schneider). 15 415V, 4-pole, 630A 16 LT Cabling work: 17 S & Delivery of one number 1.1 KV GradeXLPE insulated andPVC sheathed aluminium conductor cable (Armoured) conforming to IS: 7098 / 1988 with its latest amendment of following size. [ Make Nicco / Fort Gloster /Havells/ Polycab/ RR Kable] 18 4 Core 300 Sq. mm² 19 4 Core 240 Sq. mm² 20 4 Core 185 Sq. mm² 21 4 Core 95 Sq. mm² 22 4 Core 70 Sq. mm² 23 4 Core 50 Sq. mm² 24 Layingof 1.1 KV GradeXLPE insulated andPVC sheathed aluminium conductor cable (Armoured)of following size in the existing Masonary trench as required andas per GS. 25 1 no. 4 Core 300 mm² 26 1 no. 4 Core 240 mm² 27 1 no. 4 Core 95 mm² 28 Laying of 1.1 KV GradeXLPE insulated andPVC sheathed aluminium conductor cable ( Armoured )of following sizeon existing cable tray/ supports as to GS. 29 1 no. 4 Core 300 mm² 30 1 no. 4 Core 240 mm² 31 1 no. 4 Core 185 mm² 32 1 no. 4 Core 95 mm² 33 1 no. 4 Core 70 mm² 34 1 no. 4 Core 50 mm² 35 Laying of 1.1 KV GradeXLPE insulated andPVC sheathed aluminium conductor cable ( Armoured )of following sizethrough RCC/Hume/G.I. pipe as to GS. 36 1 no. 4 Core 300 mm² 37 1 no. 4 Core 240 mm² 38 1 no. 4 Core 185 mm² 39 Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish 40 1 no. 4 Core 70 mm² 41 1 no. 4 Core 50 mm² 42 Straight through Jointing of cable of different size by compound jointing kit including S&F ferrul, tapes and jointing materials (Brand approved by EIC) as to GS for following: 43 3.5 / 4 Core 300 mm² Al cable 44 3.5 / 4 Core 240 mm² Al cable 45 3.5 / 4 Core 185 mm² Al cable 46 Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : 47 4 Core 300 mm 48 4 Core 240 mm² 49 4 Core 185 mm² 50 4 Core 95 mm² 51 4 Core 70 mm² 52 4 Core 50 mm² 53 Finishing the ends of single core . Ar / copper cable & S&F of copper socket , colour maching tape etc as to GS for following: 54 300 sq. mm² 55 240 sq. mm² 56 185 sq. mm² 57 95 sq. mm² 58 70 sq. mm² 59 50 sq. mm² 60 S&F of 80mm diamedium gauge GI Pipe ( ISI-Medium) for vertical cable protection with necessary fittings and jointing metarials as required. 61 S&F of 80 mm dia Heavy gauge PVC Pipe ( ISI-Medium) for horizontal cable protection with necessary fittings and jointing metarials as required. 62 S&F of special type angle Support for holding the cable by horizontally run. The above clamp made of 50 x 50 x 6 mm. angle iron with half round type MS clamp for rigidly holding the cable. The above clamp made of 40 x 3mm. thick flat iron patty incl. nuts, bolts & washers etc. The length of angle support as required for 4 Core 400/300/240/185/150 mm² XLPE, Ar./Al. cable. The total iron strucutre will be hot-dip Galvanized .The structure will be fixied on wall by proper grouting inside the wall and mending good the damagesas per direction of the EIC.[For 4 nos Cable run]. 63 S & Installation of Electro Zinc Galvanised Hot Dip Galvanised (105 / 400 mm outdoor type) Wiremesh cable Trayin accordance with standard BSEN 12329-2000 with all mounting accessories.Fire test certification should be published in accordance with the E30/E90 standard. Electrical continuity across a coupling should be demonstrated by means of a published test method and result.[MAKE: LEGRAND/eqv] 64 Supply & Fixing of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support. 65 300x50x1.25 mm (18SWG) with 25x25x6mm angle iron support. 66 400x50x1.25 mm (18SWG) with 35x35x6mm angle iron support. 67 Misc. Electrical works for different S/S & panel rooms: 68 S&F of Double Door Type 8 Way Vertical TPN PDB in S.S. enclosure with IP-42/43 protectionconsisting with 1 no160 A., 4-Pole MCCB (36KA) as incomer, 8 nos. 63A. TP MCB as outgoing. and both side cable end box complete with all connection with suitable size of Cu. wire with proper socketing on wall by suitable size of angle iron frame incl all accessories as per direction of E.I.C. (Make:-Legrand / LK/ Schneider) 69 S&F of Double Door Type 6 Way Vertical TPN PDB in S.S. enclosure with IP-42/43 protectionconsisting with 1 no125 A., 4-Pole MCCB (36KA) as incomer, 6 nos. 63A. TP MCB as outgoing. and both side cable end box complete with all connection with suitable size of Cu. wire with proper socketing on wall by suitable size of angle iron frame incl all accessories as per direction of E.I.C. (Make:-Legrand / ABB/ Schneider) 70 S&F of 240 V A.C. Exhaust Fan (EPC Electrical Pvt. Ltd. - Heavy Duty) incl. Cutting hole on wall with Nuts, Bolts, washers etc. on wall and mending good the damages to original finish as per direction of the EIC for following sizes:- 71 300 mm (12) sweep 1420 RPM 72 375 mm (15) sweep 970 RPM 73 S&F of L shape Cowl made of G.I sheet of suitable size having length 600mm with 4 nos 20x3mm MS flat support and S&F of wire mess at the ends of the said cowl with nuts, bolts etc as reqd. for following sizes exhaust fans:- 74 300 mm (12) sweep 75 375 mm (15) sweep 76 Marking of identification number/nomenclature of ACB/ MCCB/ Main switch/ VTPN/ HTPN / SPN DBs/ Starters etc after installation by suitable size identification plate or painted block letter matters as per direction of the EIC. 77 S&F of 240 V, 1200 mm Sweep, A.C. Ceiling Fan 5-star without Regulator & Down Rod incl. Canopy, Fan Blades etc. and engraving & Painting the Departmental Number (up to 14 digit) on Fan Body with black japan paint and interconnection complete in all respect. [Make: Crompton,/ Orient/Usha ] [for Sub-station rooms/ panel rooms] 78 S&F of 230 V., 18 (450mm) 4 (four) Blades Industrial type Air-Circulator Pedestal Fan complete with all accessories such as Regulator, Cord and 15 Amp. 3-pin Top(Make - E.P.C.Electrical Pvt. Ltd., Heavy Duty). 79 S&F of 90 Watt LED street light ( IP 66 ),Luminarie Efficacy-120 lm/W incl. 50,000 burning hrs @L70, aerodynamically designed with better thermal management with separate lamp housing with heatresistant toughened glass & control gear housing and potted driver provided with surge protection suitable for mounting on 50 mm dia (OD)existing Arm bracket [Make- Philip/ Osram/Wipro /crompton/ Bajaj) 80 S&F of 150 Watt LED street light ( IP 66 ),Luminarie Efficacy-120 lm/W incl. 50,000 burning hrs @L70, aerodynamically designed with better thermal management with separate lamp housing with heatresistant toughened glass & control gear housing and potted driver provided with surge protection suitable for mounting on 50 mm dia (OD)existing Arm bracket[Make- Philip/ Osram/Wipro /crompton/ Bajaj) 81 Supply & fixing of 300W , high power LED floodlight luminaire (IP 66/65), Luminarie Efficacy-120 lm/W incl. 50,000 burning hrs @L70 with built in-built Surge protection ( 4 KV) & External Surge protection (10 KV)and Operating Temperature 0°C to +50°C ( maintenance free system suitable for area lighting high mast with pressure die cast aluminium housing & toughened glass cover suitable for operation on 230V +/- 6%, 50 Hz A.C. supply, on High mast Pole including all accessories as per direction of EIC. [Make- Philip/ Osram/Wipro /crompton/ Bajaj) 82 Digital Multifunction meter for HV distribution & measurement of A, V, F, pf, KW, KVA, KVAR, KWH, Freq., Odd harmonics upto 15th with 2 DI & 2 DO and Class : 0.5, peak demand, battery backed up Real time clock, inbuilt dual Ethernet port and Data logging. The Meter will be fixed on fornt panel of existing Incomer & outgoing HT breakers at different Sub Station after disconnection & taken down the existing Ammeter including necessary cutting or blocking the cutout the existing meter posision by own tools & takels and wiring by suitable PVC copper wire (FRLS) with Termination and commissioning the MFM meter as per direction of EIC. The above meters will be communicated by the existing SCADA system of 33 KV Sub Station. (Make : Schneider/ Simens/ABB/L&K ). 83 Communicable Relay for existing Incomer & outgoing HT breakers at different Sub Station after disconnection & taken down the existing Relay including necessary cutting or blocking the cutout the existing Relay by own tools & takels and wiring by suitable PVC copper wire (FRLS) with Termination and commissioning the Relay. The specification of Reay same as above HT 4 panel mentioned in Separate GTP as per direction of EIC.The above Relays will be communicated by the existing SCADA system of 33 KV Sub Station. (Make : Schneider/ Simens/ABB/L&K ). 84 Dismantling the existing damaged LED indication lamps from front door of panels very carefully and refixing the new LED lamps (Red, Yellow, Blue, Green, Orange and White) including necessary connection as per direction of EIC. (Make :- Siemens / Schneider /ABB/ LK) 85 Voltage Range : 160 - 250 V AC. 86 a) RED 87 b) YELLOW 88 c) BLUE 89 d) GREEN 90 e) ORANGE 91 f) WHITE 92 Voltage Range : 24 V DC 93 g) RED 94 h) YELLOW 95 i) BLUE 96 j) GREEN 97 k) ORANGE 98 l) WHITE 99 Earthing work: 100 Earthing with 65 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 No. 50 mm x 6 mm galvanized (Hot Dip) steel strip (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including finishing both ends by making holes etc. and S & F 65 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts (For Main LT Panel at SS-I & II) 101 Earthing with 50 mm dia GI pipe (TATA-M ) 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S &F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level incl Excavation of soil for installatio of earth electrode and filling & ramming (For Sub Panels & Pillar Box) 102 Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with lockingrrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe 103 Extra for treatment of soil by using salt & charcoal or coke for plate electrode 104 Excavation of soil for installation of Earth Electrode and filling& ramming. For Soft Soil 105 S&F of busbar of galvanized (Hot Dip) MS flat 50 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required 106 Connecting the equipments body to earth busbar incl. S & F 50 mm x 6 mm Galvanized (Hot Dip) MS flat on wall/floor with GI saddle as required and connection to equipments with incl. drilling holes, bolts, nuts,washers etc. 107 Connecting the equipments body to earth busbar incl. S & F 25 mm x 6 mm Galvanized (Hot Dip) MS flat on wall/floor with GI saddle as required and connection to equipments with incl. drilling holes, bolts, nuts,washers etc. 108 Necessary minor Civil/ Mechanical works : 109 Providing masonary cable trench extension after cutting all sorts of soil.The inside mearsurment of trench 600mm width x760 mm depth incl 250 mm thick brick work with 1st class brick cement mortorr (1:4) on both sides and bottom of the trench consisting with 100 mmthick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling 15mm thick (1:4) cement plaster to inside wall & 3mm thick neat cement furnish. 110 Providing detachable pre-cast RCC cover slabs (125 mm thick, 200 tonn load bearing capacity) over external portion of cable trench as per direction of EIC. 111 Supply, fabrication and placing/fixing MS checkered plate made of 6mm thick incl 30mm x 30mm x 6mm MS angle iron structure welded by fixing insert plates at 4 sides in cable trench top with 2 nos 3/8 TMT handle rodincl gas cutting, grinding & drilling with one coat of red laid primer and one coats of synthetic enamel paint as per direction of EIC. 112 Core cutting of 125mm thick RCC slab by suitable core cutting machine for passing necessary vertical run of Electrical Bus duct/ cables/ cable tray/ protection pipes/ earthing strip etc including mending good the damages as per direction of the EIC. 113 Minor civil works for cutting floor/ brick wall for passing electrical cables/ cable tray/ protection pipes/ earthing strip etc including mending good the damages as per direction of the EIC. 114 Supply, transporation & pouring of HSD Oil. 115 Less : Cost Item 116 Less : Cost for dismantling & unserviceableold LT Panel ( 1250A ACB-2 Nos, 1000A B/C-1,2000A Bus-Bar- 2 Sets, 250A - 630A SFU SFU - 12 Nos) installed at Gr Floor of Sub Station-IV as per direction of EIC 117 Less : Cost for dismantling & unserviceableold LT Panel ( 1600A ACB-1 Nos, 1250A ACB-1No & 1000A ACB -1 No.,2500A Bus-Bar- 01 Sets) installed at Gr Floor of Sub Station-I as per direction of EIC 118 Less : Cost for dismantling & unserviceableold LT Panel ( 400A SFU-2 Nos, 400A C/O-1No, 630A Bus-Bar, 63 - 125A SFU - 7Nos) installed at Gr Floor,Eastern side ofof UCM Building as per direction of EIC 119 Less : Cost for dismantling & unserviceableold LT Panel ( 400A SFU-2 Nos, 400A C/O-1No, 630A Bus-Bar, 63 - 125A SFU - 16 Nos) installed at Gr Floor, Western side side ofof UCM Building as per direction of EIC 120 Less : Cost for dismantling & unserviceableold LT Panel ( 400A SFU-1 Nos, 630A Bus-Bar, 125A - 250 SFU - 6 Nos) installed at Gr Floor,Eastern side ofof UCM Building as per direction of EIC 121 Less : Cost for dismantling & unserviceableold LT Panel ( 400A SFU-1 Nos, 630A Bus-Bar, 63 - 125A SFU - 6 Nos) installed at Gr Floor, Ronald RossBuilding as per direction of EIC 122 Less : Cost for dismantling & unserviceableold LT Panel ( 1250A SFU-1 Nos,200A Bus-Bar, 63 - 125A SFU - 4 Nos) installed at Gr Floor, Ronald RossBuilding as per direction of EIC 123 Less : Cost for dismantling & unserviceableold Feeder Pillar Box ( 125A SFU-1 Nos, 200A Bus-Bar, SFU unit & Starter) installed in front fo RMO Quater Gr Floor, Ronald RossBuilding as per direction of EIC 124 Less : Cost for dismantling & unserviceableold 250 - 63A SFU with enclosure installed at different places of Sub Station buildings in the campus of IPGME&R-SSKM Hospital as per direction of EIC 125 Terms and Condition: 126 The Agency must procure the materials from the Manufacturer / OEM or from their authorised sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them. 127 Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution, of work/submission of bill. 128 If any refurbished material is supplied and installed, penal action will be taken as per existing rules 129 Defect Liability period 1 (One) Year 130 (Rates should be Quoted inclusive ofall taxes & duities and L.W.C. @ 1% as applicable)
Contract Date : 14 Nov, 2025   |   Contract Value : 2.07 Crore
BRR : 7403615 Supply, Installation, Test Run And Commissioning Of Electrical Substation Including Allied Electrical Works At Kalyani Duck Breeding Farm, Slf Campus, Kalyani, Nadia-41235 Under West Bengal Livestock Development Corpn.Ltd., Lb-2, Sector-Iii, Kolkata. , Electrical Work / Installation , Transportation, Carriage, Loading & Unloading Of The Vcb& Apfc Panel To The Site. , Transportation, Carriage, Loading & Unloading Of Thetransformer To The Site. , Installation, Testing, Commissioning Of 500 Kva, 11/0 415 V Dry Type Indoor Distribution Transformer, Including Carriage With Within A Lead Of 30 M By Placing In Position ,Assembling Living Up Leveling And Fixing On The Floor, And Checking All Component ,Correctly Set According To Requirement And Including S And F Base Frame As Requirement , Totally Repairing Of Enclosed Single Panel Metal Clad 630 Ampere Indoor Type Ht Vacuum Circuit Breakersuitable For 11 Kv,Three Phase 50 Hz Ac Main Power Supply Including Carriage, Positioning, Assembling, Repairing And Supply Of Power Bank, Internal Wirrings, Spouts-3 Nos, Ct Coil- 3 Nos,Relay Correct Set According To Requirement. , Installation Of 630 A Vcb Complete With All Necessary Connections Including Carriage Within A Lead Of 30 Mtrs By Placing In Position, Assembling Living Up, Leveling And Fixing On The Floor, Fitting And Checking All Component, Correctly Set According To Requirement And Including S And F Base Frame As Requirement , Supply And Delivery Of Cubical Type Lt Distribution Panel Board Of Appropriate Size Base Mounted Compartmentalized With Maple Arrangement Having Rigid And Self Supporting Structure Fabricated From 3 Mm Thick Crca Sheet Steel With M/S Angle Frame The Panel Board Consisting Of The Following Switches A) Incoming Arrangement Supply And Fixing In A Separate Chamber Microprocessor Based 50Hz 415V 800 Ampere Breaking Capacity 65 Ka Electrical Drawout Type Acb With Ipr To 4 Pole -1 Nos B) Bus Section 500 Volt 1000 Ampere Aluminium Bus Barwith Vertical Section Of Appropriate Size For Neutral And Phases. , A Bus Bar Shall Be Fixed With Frp Chair And The Entire Bars Are Insulated With Pvc Heat Sinkable Cable Sleeve Of Suitable Size And Colour As Par Direction Of E.I.C. B)Switch This Connector Fuse (Panel Mounting Cubical Type) Confirm To Is: 13947 In Pen Execution 3 Pole And Neutral Ac 23 Ampere 50 Hertz 415 V 200 A - 3 Nos 400 Ampere Din Type Hbc Fuse Link And Spreader Links -2 Nos C) Switch Disconnect Or Fuse (Panel Mounting Cubical Type) Confrom To Is:13947 In Pen Execution Three Pole And Neutral Ac 23 Ampere 50 Hertz 415 Volt 160 Ampere- 3 Nos 160 Ampere Din Type Hbcfuse Link-2 Nos , D) Switch Disconnect Of Use (Panel Mounting Cubical Type) Confrom To Is: 13947 In Pen Execution 3 Pole And Neutral Ac 23 Ampere 50 Hertz 416 Volt 63 Ampere With 3 Numbers 63 Amperedin Type Hbc Fuse Link- 2 Nosmetering Panela)S And Fixing 0-500 Volt Voltmeter Of Size 96 Metres Millimetre Square (Square Type) Ae Make -1 No B) S And Fixing 0-500 Ammeter Of Size 96 Mm Square Type Ar Make -1 No C) S And F Rotary Type Voltmeter Selector Switch Off 10 Ampere Kaycee Make -1 No D) S&F Rotary Type Ampere Metre Selectorswitch Of 10 Ampere Kaycee Make -1 No E) S And F Current Transformer Of Size 500 / 5A Kappa Make -3 No F) S And F 20 Ampere Bakelite Fuses Base And Bridge With 4 Ampere Hrc Fuse Link Ge Make -3 Nosg) S&F Danger Board -1 No Inter Connection: All Interconnection Of Switches And Bus Bar Shall Be Made With Suitable Size Copper Bar To Be Kept For Cable Connection For Main Switchesand Change Over And The End Of All Connections Ofmetering. , Outgoing 400A 4 Pole Mccb-1 No.250A 4 Pole Mccb- 2 Nos.160A 4 Pole Mccb- 2 Nos.100A 4 Pole Mccb- 1 No. 63A 4 Pole Mcb - 2 Nos. , Supply Of 11 Kv Grade 3.5 Core 240 Sqmm Pvc Insulated Armoured Xlpe (E) Htcable With Aluminium Conductor. (Mescab/Gloster Make) , Laying Of 11 Kv Grade 3.5 Core 240 Sqmm Pvc Insulated Armoured Xlpe (E) Htcable As Required. , Finishing The End Of Following Xlpe/Pvc Armoured Cables By Crimping Method Incl. Supplying And Fixing Solderless Socket (Dowels Make), Tapes, Anticorrosive Paste & Jointing Materials : , 3.5 Core 185 Sq.Mm. Page-F5, Item-8(B)(Xxi) , Supplying And Fixing Compression Type Gland Complete With Brass Gland, Brass Ring & Rubber Ring For Dust & Moisture-Proof Entry Of Xlpe/Pvc Armoured Cables As Below : , 3.5 Core 185 Sq.Mm. , Installation Of Apfc Panel Complete With All Necessary Connections Including Carriage Within A Lead Of 30 Mtrs By Placing In Position, Assembling Living Up, Leveling And Fixing On The Floor, Fitting And Checking All Component, Correctly Set According To Requirement And Including S And F Base Frame As Requirement , Supply And Fitting And Fixing Of 12 Kv (5 Ka) Lighting Arrester , Making , Testing , Arrangement And Submitting The Test Report For High Voltage Testing Of Specified Voltage Including Checking And Testing Of All Hd / Lt Equipment By Authorised Firm Of Directorate Of Electricity , S&F 9 Litre Capacity Round Fire Bucket Including S&F Ms Hook And Duly Filled Up By Sand As Directed By Eic , 02 Kg Capacity With Isi Marked Co2 Type Fire Extinguisher Squeeze Grip Type Conforming To Is:15683:2006 Made From Seamless Cylinder Conforming To Is:7285 Duly Approved By Chief Controller Of Explosive,Nagpur, Fitted With Isi Marked Controller Of Explosive,Nagpur, Fittet With Isi Marked Controlled Valve Conforming To Is:3224, Discharge Adopter And Horn Complete With Initial Gas Charged With Carrying Handle And Wall Mounting Bracket Suitable For Operating Between (-)30ºc To (+)55ºc. Fire Rating -8B , S&F Best Quality First Aid Box (Aluminium Body) As Per Pwd Specification Completed With All The Item As Required By Rules Of Substation On Ms Bracket On Wall Including Mending Good The Damage To Original Finish , S&F Shock Treatment Chart Pasted On Hard Board On Wall With Screw As Required , S&F 11 Kv Rubber Hand Gloves , Supply And Delivery 6 X3 X0.5 Rubber Mat For 11 Kv Substation .Best Quality And Isi Approved , S& F E.I. Danger Board Of Size 20Cm X 30Cm On Wall , Arrangement Of Different Types Of Routine Test And Commissioning Of 1 Transformer , 1 Lt Vcb And 1 Lt Panel As Per Is2026 And Commissioning The Installation After Obtaining The Approval From The Director Of Electricity As Direction Ofeic , Excavation Of Soil For Installation Of Earth Electrode And Filling & Ramming. (A) For Soft Soil. , Earthing With 80 Mm Dia Gi Pipe (Tata-Medium)X 3.0 Mts. Long And 1 No. 65 Mm X 8 Mm Galvanized (Hot Dip) Steel Strip (4 Mts. Long), 20 Mm Dia X 125 Mm Long Galvanized Bolt, Double Nuts, Double Washers Including Finishing Both Ends By Making Holes Etc. And S & F 80 Mm Dia Gi Pipe (Isi-Medium) Protection (3 Mts. Long) To Be Filled With Bitumen Partly Under The Ground Level And Partly Above Ground Level To An Average Depth Of 3.65 Mts. , Earthing With 50 Mm Dia Gi Pipe 3.64 Mm Thick X 3.04 Mts. Long And 1 X 4 Swg Gi (Hot Dip) Wire (4 Mts. Long), 13 Mm Dia X 80 Mm Long Gi Bolts, Double Nuts, Double Washers Incl. S & F 15 Mm Dia Gi Pipe Protection (1 Mts. Long) To Be Filled With Bitumen Partly Under The Ground Level And Partly Above Ground Level Driven To An Average Depth Of 3.65 Mts. Below The Ground Level As Below: Tata Medium , Extra For Providing Masonery Enclosure On The Top Of The Earth Electrode Of Overall Size 86.36 Cm X 86.36 Cm X 46 Cm Deep (Below Ground Level) Complete With Cemented Brick Work(1:6) Of 25 Cm Width Duly Plastered With Cement Morter (Inside) Ci Hinged Inspection Cover Of Size 36.56 Cm X 35.56 Cm With Locking Arrangement, Gi Reducer Including Drilling Of 46 Nos. 12 Mm Dia Holes On The Gi Pipe. , Extra For Treatment Of Soil By Using Salt & Charcoal Or Coke For Plate Electrode. , Supplying & Fixing Earth Busbar Of Galvanized (Hot Dip) Ms Flat 65 Mm X 8 Mm On Wall Having Clearance Of 6 Mm From Wall Including Providing Drilled Holes On The Busbar Complete With Gi Bolts, Nuts, Washers, Spacing Insulators Etc. As Required. , Supplying & Fixing Earth Busbar Of Galvanized (Hot Dip) Ms Flat 50 Mm X 6 Mm On Wall Having Clearance Of 6 Mm From Wall Including Providing Drilled Holes On The Busbar Complete With Gi Bolts, Nuts, Washers, Spacing Insulators Etc. As Required. Page-G-2, Item-4 (C) , Supplying & Fixing Of High Density H.T. Earth Bar Insulator Sleeves For Line Protection. , L.T. Portion Electrical Work / Installation , Supply Of 2 Core 10 Sqmm Pvc Insulated 1100 Volt Al. Armoured Xlpe Cable. Reputed Make. , Laying Of Cable Upto 2 Core 25 Sqmm On Wall/Surface Incl. S & F Ms Saddles With Earthing Attachment In 10 Swg Gi (Hot Dip) Wire, Making Holes Etc. As Necy. Mending Good Damages And Painting. , Supplying And Fixing Compression Type Gland Complete With Brass Gland, Brass Ring & Rubber Ring For Dust & Moisture-Proof Entry Of Xlpe/Pvc Armoured Cables As Below : , For 2 Core X 10 Sq. Mm. , Finishing The End Of Following Xlpe/Pvc Armoured Cables By Crimping Method Incl. Supplying And Fixing Solderless Socket (Dowels Make), Tapes, Anticorrosive Paste & Jointing Materials : , For 2 Core X 10 Sq. Mm. , Supplying And Fixing Double-Door Spn Mcb Distribution Board With Ip-42/43 Protection, Concealed In Wall After Cutting The Wall & Mending Good The Damages To Original Finish Incl. Inter Connection With Suitable Size Of Copper Wire And Neutral Link & Provision For Earthing Attachment. L&T Make. 2+10 Way. , Supplying And Fixing 240/415 V Mcb Of Breaking Capacity 10Ka & C Characteristics On Din Rail Of Existing Dbs And Necessary Connection. Dp 40A. L&T. Make. , Supplying And Fixing 240/415 V Mcb Of Breaking Capacity 10Ka & C Characteristics On Din Rail Of Existing Dbs And Necessary Connection. Sp 6-32A. , Distribution Wiring In 1.1 Kv Grade 2X22/0.3 (1.5 Sqmm) Single Core Stranded Fr Pvc Insulated & Unsheathed Copper Wire With 1X22/0.3 (1.5 Sqmm) Single Core Stranded Fr Pvc Insulated & Unsheathed Copper Wire (Brand Approved By Eic) For Ecc In 19 Mm Bore, 3 Mm Thick Polythene Pipe Complete With All Accessories Embedded In Wall For Horizontal & Vertical Runs And In Suitable Size Pvc Casing-Capping (Precision Make) For Ceiling Portion Only, Incl. Necy. Fittings Etc. To Light/Fan/Call Bell Point With Modular Type Switch (Brand Approved By Eic) Fixed On Modular Gi Switch Board With Top Cover Plate And 2 No. Suitable Size “Ph & N” Copper Bar & Earthing Attachment Flushed In Wall Incl. Mending Good Damages To Original Finish [Only Pvc Casing-Capping On Ceiling And Remaining Portion Concealed]. Average Run 9 Mtr. , Distribution Wiring In 1.1 Kv Grade 2X22/0.3 (1.5 Sqmm) Single Core Stranded Fr Pvc Insulated & Unsheathed Copper Wire (Brand Approved By Eic) In Suitable Size Pvc Casing-Capping (Precision Make) With 1X22/0.3 (1.5 Sqmm) Single Core Stranded Fr Pvc Insulated & Unsheathed Copper Wire For Ecc, Incl. Necy. Fittings Etc. With S & F 6A 5 Pin Modular Type Plug Socket And Switch (Brand Approved By Eic) Fixed On 4 Module Gi / Pvc Switch Board With 3/4 Module Top Cover Plate On Wall Incl. Necy. Connection Making Earthing Attachment, Painting And Mending Good Damages To Building Works [Pvc Casing-Capping And Plug Box Both On Surface]. , On Board , Average Run 1.5 Mtr , Supply & Fixing 240V, Modular Socket (2 Module) Type Fan Regulator (Step Type) (Brand Approved By Eic) On Existing Modular Gi Switch Board With Top Cover Plate Incl. Making Necy. Connections Etc. , Fixing Only Modular Type Fan Regulator On Existing Modular Gi Switch Board With Top Cover Plate Incl. Making Necy. Connections Etc. , Distribution Wiring In 1.1 Kv Single Core Stranded Fr Pvc Insulated & Unsheathed Copper Wire (Brand Approved By Eic) In 20Mm Size Pvc Rigid Conduit Fr (Precision Make) Incl. Necy. Fittings As Required. Page- , 2X 36/0.3 (2.5 Sqmm) + 1 X 22/0.3 (1.5 Sqmm) Ecc , Supply, Fitting & Fixing Of 400 Mm Dia High Speed Revoling Wall Mounted Fan. Hi-Flow. Crompton Make) , Led Flood Light 50 Watt. Jfl 50W-G. Lheecnp7pb6j050 Centura Neo Led Flood Light 50 W 6500 K Ip-66 , Supply, Fitting & Fixing Of Led Lamp 9W (Havells / Syska Make) , Supply Of 1200Mm Long Led Fl Light Set. (Havells/Wipro Make) , Supply Of 450Mm Dia Exhaust Fan Metal Body.Heavy Duty. (Havells / Epc / Crompton Greeves Make) , Supply Of 1200 Long A.C. Ceilingfan Complete With All Accessories. (Crompton Greeves/Usha Make) , Fitting & Fixing Of A.C Ceiling Fan . , S.I.T.C. Of 600 Mm Hi Speed Metal Body Stand Fan With Its Stand And All Accessories Complete. (Crompton Greeves Make). , Distribution Wiring In 1.1 Kv Single Core Stranded Fr Pvc Insulated & Unsheathed Copper Wire (Brand Approved By Eic) In 20Mm Size Pvc Rigid Conduit Fr (Precision Make) Incl. Necy. Fittings As Required. , 2X 56/0.3 (2.5 Sqmm) + 1 X 36/0.3 (1.5 Sqmm) Ecc , Supply & Fixing 240 V, 2 Nos. 6A, & 2 Nos. 20A Plug Socket With Separate 2 Nos. 6 A & 2 Nos. 20A Modular Switch, (Brand Approved By Eic) On Modular Board In Wall Incl. S & F 240X200x65 Mm Modular Switch Boardand Making Necessary Connections As Required , Supply, Fitting & Fixing Of 12Mm Long Led Fl Set Complete Withh All Accessories On Wall. , Supply, Fitting & Fixing Of Led Ceiling Mounted Fittings.(Wipro / Bajaj / Syska Or Similarmake) 110Mm Dia. , Supply, Fitting & Fixing Of Led Ceiling Mounted Fittings.(Wipro / Bajaj / Syska Or Similarmake) 80 Mm Dia. , Supply, Fitting & Fixing Of Call Bell (Buzzer). , Supply & Fixing Of 225Mm Dia Exhaust Fan. (Crompton Greeves Make) , Distribution Wiring In 2 X 22/0.3 (1.5 Sqmm) Single Core Stranded Fr Pvc Insulated & Unsheathed Copper Wire (Brand Approved By Eic) In 20Mm Size Pvc Rigid Conduit Fr (Precision Make), With 1X22/0.3 (1.5 Sqmm) Single Core Stranded Fr Pvc Insulated & Unsheathed Copper Wire For Ecc, To Light/Fan/Call Bell Points With Modular Type Switch (Brand Approved By Eic) Fixed On Modular Gi Switch Board With Top Cover Plate And 2 No. Suitable Size “Ph & N” Copper Bar & Earthing Attachment Fixed On Wall Incl. Mending Good Damages To Original Finish. , 2X22/0.3 (Ph. & N) And 1X22/0.3 As Ecc , Average Run 10Mtrs. , Finishing The End Of Following Xlpe/Pvc Armoured Cable , 4 Core X 6 Sq.Mm. , 4 Core X 10 Sq.Mm. , Supply & Fixing Of Compressive Type Gland Complete With Brass Gland. , 4 Core X 6 Sq.Mm. , 4 Core X 10 Sq.Mm. , Supplying And Fixing Double-Door Spn Mcb Distribution Board With Ip-42/43 Protection, Concealed In Wall After Cutting The Wall & Mending Good The Damages To Original Finish Incl. Inter Connection With Suitable Size Of Copper Wire And Neutral Link & Provision For Earthing Attachment. (L&T2+2 Way). Enclosure (Ltsd04n) With 40 A 4 Pole Mcb. , Supply And Fixing Of Industrial Plug Socket 3 Phase 5 Pin (3 Phase, 1 Neutral And 1 Earting) With Metal Enclosure 3/4 Pole Mcbs All Accessories Complete. 32 Amp. , Supply And Fixing Of Industrial Plug Socket 3 Phase 5 Pin (3 Phase, 1 Neutral And 1 Earting) With Metal Enclosure 3/4 Pole Mcbs All Accessories Complete. 16 Amp. , Supply Of 4C X 25 Sqmm Aluminium Armoured Cable Of 1.1 Kv Grade. Make - Mescab/Polycab/Gloster , Supply Of 4C X 10 Sqmm Aluminium Armoured Cable Of 1.1 Kv Grade. Make - Mescab/Polycab/Gloster , Laying On Pole With Clamps:- Fixing Of Cable Along The Lenth Of O.H. Pole Incl. S & F Ms Pole Clamps Fabricated From 25 Mm X 6 Mm Ms Flat Incl. Painting , Finishing The End Of Following Xlpe/Pvc Armoured Cables By Crimping Method Incl. Supplying And Fixing Solderless Socket (Dowels Make), Tapes, Anticorrosive Paste & Jointing Materials : 4 Core 25 Sqmm Cable , Finishing The End Of Following Xlpe/Pvc Armoured Cables By Crimping Method Incl. Supplying And Fixing Solderless Socket (Dowels Make), Tapes, Anticorrosive Paste & Jointing Materials : 4 Core 10 Sqmm Cable , Supplying And Fixing 415 V Four Pole Mccb Of Breaking Capacity 25Ka/35Ka With Fixed Thermal And Fixed Magnetic / Adjustable Thermal And Fixed Magnetic Setting In Existing Dbs / Enclosure And Necessary Connection. 100 A Fp Legrand , Supplying And Fixing 240/415 V Mcb Of Breaking Capacity 10Ka & C Characteristics On Din Rail Of Existing Dbs And Necessary Connection. 63A Fp Legrand , Supplying And Fixing Mccb Ss Enclosure With Ip- 20/30 Protection, Pwder Coated Provision For Housing Four Pole (4P) Mccb, Concealed In Wall After Cutting The Wall & Mending Good The Damages To Original Finish / On Flat Iron Frame Incl. Painting, Connection & Provision For Earthing Attachment. Legrand , Supplying And Fixing Mcb Ss Enclosure With Ip-20/30 Protection, Powder Coated Provision For Two/Four Pole Mcb, Concealed In Wall After Cutting The Wall & Mending Good The Damages To Original Finish Incl. Painting, Connection & Provision For Earthing Attachment. 2 Way. , Supplying And Fixing 240/415 V Mcb Isolator On Din Rail Of Existing Dbs And Necessary Connection. 63 A Legrand Fp , Supplying And Fixing 240/415 V Mcb Of Breaking Capacity 10Ka & C Characteristics On Din Rail Of Existing Dbs And Necessary Connection. 6-32A Sp Legrand , Supplying And Fixing Double Door Horizontal Tpn Mcb Distribution Board With Ip-42/43 Protection, Concealed In Wall After Cutting The Wall & Mending Good The Damages To Original Finish Incl. Inter Connection With Suitable Size Of Copper Wire And Neutral Link & Provision For Earthing Attachment. 4 Way Enclosure (607715) Legrand , Supplying & Fixing Sheet Metal (16 Swg) Iron Clad Busbar Chambers On Angle Iron Frame On Wall, Incl. Earthing Attachment And Painting As Required – (As Per Drawing No. 470 Of Pwd Specification Book – May 1991). 4 Bars 415 V, 100/125 A Dimension Of Al. Bars [85Mm Long] 4 X 25X5mm Dimension Of Sheet Metal Box 500X150mm , Distribution Wiring In 1.1 Kv Single Core Stranded Fr Pvc Insulated & Unsheathed Copper Wire (Brand Approved By Eic) In 20Mm Size Pvc Rigid Conduit Fr (Precision Make) Incl. Necy. Fittings As Required. 2 X 56/0.3 (4 Sqmm) + 1 X 36/0.3 (2.5 Sqmm) Ecc , Distribution Wiring In 1.1 Kv Single Core Stranded Fr Pvc Insulated & Unsheathed Copper Wire (Brand Approved By Eic) In 20Mm Size Pvc Rigid Conduit Fr (Precision Make) Incl. Necy. Fittings As Required. 2 X 36/0.3 (2.5 Sqmm) + 1 X 22/0.3 (1.5 Sqmm) Ecc , Supply & Testing Of Industrial Type Led ( Box ) Double Fl Fittings 1200 Mm Long With Detachable Double Led Tube Set, Front Detachable Acrylic Cover. , Fixing Only Single/Twin Fluorescent Light Fitting Suspended 60 Cm Bellow The Ceiling With 2 No. 20 Mm Dia Ei Conduit (14 Swg) Supports Fixed With “L” Type Ms Clamp Whose One Side Fixed On Ceiling With Sutable Size 4 Nos. Fastener And Other Side Connected With The Conduit With Suitable Size Of Bolts And Nuts Incl. S&F Ei Conduit, “L” Type (125Mmx125mm) 6Mm Thick And 25Mm With Ms Clamps And Connecting The Length Of Pvc Insulated Wire And Mending Good Damages To Original Finish And Painting Etc. By 2X24/0.20 Mm (1.5Sqmm.) Flexible Copper Wire Of 1.50 Mt. Length. , Break Down Repairing Work Of Over Head Line With All The Arrangments And Tools , Wiring In 1.1 Kv Grade Single Core Stranded Fr Pvc Insulated & Unsheathed Copper Wire (Brand Approved By Eic) Of Following Sizes In 25Mm Pvc Casing-Capping (Precision Make) Incl. Necy. Pvc Clips, Fittings Etc. , 2X 22/0.3 (1.5 Sqmm) + 1 X 22/0.3 (1.5 Sqmm) , 2X 36/0.3 (2.5 Sqmm) + 1 X 22/0.3 (1.5 Sqmm) Ecc , Supply Ofled Street Light Fittings Ip-65 Standard (Model:-Hpflp90w, Item Code- Lheparu7pn7j90)Make:- Havells , Fixing Only Outdoor / Street Light Type Fluorescent Light Fitting Or Mv Light Fitting Complete With All Accessories To Be Fixed /Projected From The Wall Of The Building Incl. Making Holes/Providing Clamping Arrangement & Necy. Gi Reducer As Required. S&F 40 Mm Gi Pipe (Isi-Medium) Quality 1.5 Mts. Average Length Having Suitable Bend S&F Necy. Length Of 1.5 Sqmm Pvc Insulated Single Core Stranded Annealed Copper Wire And Making Connections As Required And Mending Good Damages To Wall Incl. Painting Etc (Page-C3, Item No:-18). , Supply, Installation, Testing & Commissioning Of Lubricant Oil Filter (Fp A00300) For Ashok Leyland Make 30 Kva D.G. Set. , Supply, Installation, Testing & Commissioning Of Fuel Filter (Diesel Filter) For Ashok Leyland Make 30 Kva D.G. Set. , Supply, Installation, Testing & Commissioning Of Air Filterfor Ashok Leyland Make 30 Kva D.G. Set. , Replacement Of Battery With New One For 30 Kva D.G Set. , Supply & Insert Of Coolent For Ashok Leylandmake 30 Kva D.G. Set. , Supply & Insert Of Distilled Water For Ashok Leylandmake 30 Kva D.G. Set. , Supply Of Diesel Oil For The D.G. Set. , Supply & Replacement Of Pump Kit For Ashok Leyland Make 30 Kva D.G. Set. , Supply & Replacement Of Oil Pipes For Ashhok Leyland Make 30 Kva D.G. Set. , Supply, Changing & Filling Of Mobil Oil To The Engine, 30Kvaashok Leyland Make D.G. Set. , Repairing Of The Defective Wirings (Cause Due To Rodant Action) Ffor 30 Kvaashok Leyland Maked.G. Set. , Servicing Charges For The Entire 30 Kva Ashok Leyland Make D.G. Set With Its Engine With Other Parts. (Full Servicing). , Supply, Fitting & Fixing Of Led Ceiling Mounted Fittings.(Wipro / Bajaj / Syska Or Similarmake) , Supply, Installation, Testing & Commissioning Of Lubricant Oil Filter (Fp A00620) For Ashok Leyland Make 62.5 Kva D.G. Set. , Supply, Installation, Testing & Commissioning Of Fuel Filter (Diesel Filter) For Ashok Leyland Make 62.5 Kva D.G. Set. , Supply, Installation, Testing & Commissioning Of Air Filterfor Ashok Leyland Make 62.5 Kva D.G. Set. , Supply & Insert Of Coolent For Ashok Leylandmake 62.5 Kva D.G. Set. , Supply & Insert Of Distilled Water For Ashok Leylandmake 62.5 Kva D.G. Set. , Supply Of Diesel Oil For Thhe D.G. Set. , Supply, Changing & Filling Of Mobil Oil To The Engine, 62.5 Kva Ashok Leyland Make D.G. Set. , Repairing Of The Defective Wirings (Cause Due To Rodant Action) Ffor 62.5 Kva Ashok Leyland Maked.G. Set. , Servicing Charges For The Entire 62.5 Kva Ashok Leyland Make D.G. Set With Its Engine With Other Parts. (Full Servicing). , Supply, Testing, Fitting & Fixing Of Out Door Type Ip-65 Led Flood Light Fittings Isi Make (Model:-200W-G) Centura Neo Telescopic Flood Light Complete Withfastener Nuts And Bolts, Connection Wire Etc. Make:- Havells / Philips/Crompton Greeves. , Supply And Manufacturing Of Industrial Extension Cord Comprising Of5core 6 Sq.Mm. Copper Cable Multistrand 1100 Volt Grade With One End 5 Pin Metal Socket And One End 5 Pin Metal Top To Match With The Industrial Plug Socket. , Supply And Manufacturing Of Industrial Extension Cord Comprising Of3 Core 4 Sq.Mm. Copper Cable Multistrand 1100 Volt Grade With One End 3 Pin Metal Socket And One End 3 Pin Metal Top To Match With The Industrial Plug Socket. , Supply Of Xlpe Insulated 5 Core Multistrand 10 Sq. Mm 1100 Volt Grade Copper Cable. (Reputed Make) Isi Approved. , Supply Of Xlpe Insulated 5 Core Multistrand 6 Sq. Mm 1100 Volt Grade Copper Cable. (Reputed Make) Isi Approved. , Laying Of Cable As Below, After Cutting Floor/Pavement/Wall/ And Making Holes Incl., Embedding The Cable At An Average Depth As Below And Mending Good The Damages To Original Finish Incl. Removing The Rubbish , From 2.5 Sqmm To 35 Sqmm At An Average Depth Of 75 Mm In Floor/Pavement/Wall Etc. , Dismentalling Of 630A Vcb With Dismentlling All Its Ht Connections. , Dismentalling Of Apfc Panel With Dismentlling All Itsconnections And Dismentalling Of Ct Coil. , Shifting Of The Vcb To The Place As Directed By The Officer -In- Charge. , Shifting Of The Apfc Panel To The Place As Directed By The Officer -In- Charge. , Unearth Of Ht Cable Without Damaging It And Stagging It To Proper Position. , Laying Of One No. H.T. Cable185 Sqmm In Underground Trench 460Mm Wide X 760 Mm Average Depth, With Brick Protection On The Top Of The Cable With 8 (Eight) Nos. Bricks Per Mtr. Including Filling The Space Between The Bricks And Cable And Also The Trench With Shifted Soil, Levelling Up And Restoring Surface Duly Rammed. Page- F 2, Item No.:- 1 ((B). , Supply And Arrangement Of 1 No Straight Through Heat Sink Joint Of240 Sqmmhtcable .( Kalyani Feed Milling Plant ) Model No -3Mho_X_Aa_011E_3C0095_U40 Make- M-Seal. , Supply & Commissioning Of H.T. Terminal Jointint At Vcb Side. , Supply & Fixing 240V, Modular Socket (2 Module) Type Fan Regulator (Step Type) (Brand Approved By Eic) On Existing Modular Gi Switch Board With Top Cover Plate Incl. Making Necy. Connections Etc , Supply Of 1200 Long A.C. Ceilingfan Complete With All Accessories. (Crompton Greeves/Usha Make) , Supply Of 1Single Core X 70 Sq. Mm. Al. Conductor Cable.Xlpe Insulated, Overall Pvc Sheathed 1100 Volt Grade. , Laying Of Cable As Below, After Cutting Floor/Pavement/Wall/ And Making Holes Incl., Embedding The Cable At An Average Depth As Below And Mending Good The Damages To Original Finish Incl. Removing The Rubbish From 35 Sqmm To 95 Sqmm At An Average Depth Of 75 Mm In Floor/Pavement/Wall Etc. , Supplying & Fixing Medium Gauge Gi Pipe ( Isi-Medium) Protection With Necessary Fittings And Jointing Metarials As Required , Finishing The End Of Following Xlpe/Pvc Armoured Cable 4 Core X 70 Sq.Mm. , Supply & Fixing Of Compressive Type Gland Complete With Brass Gland.2 Core X 70 Sq.Mm , Supply Fitting & Fixing Of 250 Watt Copper Sodium Vapour Street Light Fittings Choke. , Supply Fitting & Fixing Of 250 Watt Copper Sodium Vapour Street Light Fittings Lamp. Son-T. , Distribution Wiring In 2 X 22/0.3 (1.5 Sqmm) Single Core Stranded Fr Pvc Insulated & Unsheathed Copper Wire (Brand Approved By Eic) In 20Mm Size Pvc Rigid Conduit Fr (Precision Make), With 1X22/0.3 (1.5 Sqmm) Single Core Stranded Fr Pvc Insulated & Unsheathed Copper Wire For Ecc, To Light/Fan/Call Bell Points With Modular Type Switch (Brand Approved By Eic) Fixed On Modular Gi Switch Board With Top Cover Plate And 2 No. Suitable Size “Ph & N” Copper Bar & Earthing Attachment Fixed On Wall Incl. Mending Good Damages To Original Finish. 2X22/0.3 (Ph. & N) And 1X22/0.3 As Ecc Average Run 10Mtrs. , Wiring In 1.1 Kv Grade Single Core Stranded Fr Pvc Insulated & Unsheathed Copper Wire (Brand Approved By Eic) Of Following Sizes In 25Mm Pvc Casing-Capping (Precision Make) Incl. Necy. Pvc Clips, Fittings Etc. 2X 22/0.3 (1.5 Sqmm) + 1 X 22/0.3 (1.5 Sqmm) , Supply Of 1200 Long A.C. Ceilingfan Complete With All Accessories. (Crompton Greeves/Usha Make) , Supply & Fixing Socket Type Fan Regulator (Step Type) (Brand Approved By Eic) On Existing Sheet Metal Switch Board With Bakelite/Perspex Top Cover By Screw After Making Housing For Regulator Knob By Cutting Bakelite/Perspex Top Cover Incl. Making Necy. Connections Etc. , Supplying & Fixing Iron Beam Fan Clamp Of Two Piece Type, As Per Approved Specification, Fabricated From 40 Mm X 9 Mm Ms Sheet Flat Suitable For Beam Having Flange Upto 150 Mm Wide – (As Per Drawing No. 476 Of Pwd Specification Book – May 1991) , Supply, Fitting & Fixing Of Led Lamp 9W (Havells / Syska Make) , Supply Of 1200Mm Long Led Fl Light Set. (Havells/Wipro Make) , Supply, Fitting & Fixing Of Ceiling Fan Down Rod As Per Site Requirement. 1500 Mm Long. , Supply Of 225Mm Dia Exhaust Fan Metal Body.Heavy Duty. (Havells / Epc / Crompton Greeves Make) , Fitting & Fixing Of A.C Ceiling Fan . , Supply, Fitting & Fixing Of Ceiling Fan Catcher As Per Site Requirement. , Supply & Fixing Of Fan Fixing Down Cord Copper Flexible Wire 2500 Mm Long. , Taxes & Duties , Add : G.S.T. @ 18% Of Rs. 33,52,409=70 I.E. Rs. 6,03,433=75 , Add : Cess @ 1% Of Rs. 39,55,843=45 I.E. Rs. 39,558=43
Contract Date : 28 May, 2025   |   Contract Value : 39.33 Lakhs
BRR : 10213076 Tender For ANNUAL MAINTENANCE CONTRACT Of All Lab Buildings Of Iip.(Electrical Works) 2025-26.-- 1 wiring for light point/ fan point/ exhaust fan point/ call bell point/ with 1.5sqmm FR PVC insulated copper conductor single core cable in surface/ recessed steel conduit with modular switch, modular plate, suitable GI box and earthing the point with 1.5sq.mm FRLS PVC insulated copper conductor single core cable etc as required. 2 Group-C 3 Wiring for circuit/submain wiring along with earth wire the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduitas required 4 2x1.5 sq mm + 1x1.5 sq mm earth wire 5 2x2.5 sq mm + 1x2.5 sq mm earth wire 6 2x4 sq mm +1x4 sq mm earth wire 7 2x6 sq mm + 1x6 sq mm earth wire 8 4x4 sq mm + 2x4 sq mm earth wire 9 Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 10 3 X 1.5 sq mm 11 3 x2.5 sq mm 12 3 x 4 sq mm 13 3 x 6 sq m 14 supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed/ PVC conduit as required. 15 2 pair 16 Supplying and fixing of following sizes of steel conduit along with accessories in surface/ recessed including cutting the wall and making good the same in case of recessed conduit as required. 17 20 mm 18 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recessed including cutting the wall and making good the same in case of recessed conduit as required. 19 20 mm 20 25 mm 21 Supplying and fixing metal box of following size (nominal size) on surface or in recessed with suitable size of phenolic laminated sheet cover in front including painting etc as required. 22 100 mmx 100 mmx 60 mm deep 23 180 mmx 100 mmx 60 mm deep 24 200 mmx 125 mmx 60 mm deep 25 Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc as required. 26 5/6 amps switch 27 15/ 16 amps switch 28 3 pin 5/6 amps socket oulet 29 6 pin 15/ 16 amps socket oulet 30 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. 31 5/6 amps switch 32 15/ 16 amps switch 33 3 pin 5/6 amps socket oulet 34 6 pin 15/ 16 amps socket oulet 35 Telephone socket outlet 36 Supplying and fixingtwo module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required 37 Supplying and fixingfollowing size/ modules, GI box along with modular base & cover plate for modular switch in recess etc as required 38 1 or 2 module (75 mm x 75 mm) 39 3 module (100 mm x 75 mm) 40 6 module (200 mm x 75 mm) 41 8 module (125 mm x 125 mm) 42 12 module (200 mm x 150 mm) 43 Supplying and fixing following metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in fornt including providing and fixing 6pin 5A & 15 A socket outlet and 15 A piano type switch, connection, painting etc. as required . 44 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 and 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. As required 45 Supplying and fixing 3 pin, 5A ceiling rose on the existing junction box/ wooden block including connection etc as required 46 Providing and fixing plain 16/0.20mm (0.50sqmm) twin flat flexible, FRLS PVC insulated, copper conductor cable, in PVC sleeve of suitable size on the floor/ wall, or side of the table/ door etc. as required. 47 Installation,testing and commissioning of pre-wired fluorescent fitting/compact fluorescent fitting of all types,compelete with all accessories and tube etc.directly on ceiling/wall,including connection with 1.5 sq mm FR PVC insulated copper conductor,single core cable and earthing etc. as required. 48 installation, testing and commissioning of ceiling fan, including wiring the down rod of standrand lenght ( up to 30cm) with 1.5 sq.mm FR PVC insulated, copper conductor, single core cable etc. As required 49 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc as requied upto 450 mm . 50 Extra for fixing the louvers/ Shutters completee with frame for a exhaust fan of all sizes. 51 Supplying and drawing of UTP 4 pair CAT 6 LAN cable in the existing surface/ recessed steel/ PVC conduit as required. 52 1 run of cable 53 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 2 Nos. 3 pin 5/6 amp. modular socket outlet and 5/6 amps modular switch with connection etc. As required ( for light plug to be used in Non- Residential buildings) 54 Providing and fixing following rating and breaking capacity MCCB in existing cubical panel board including drilling holes in cubical panel, making connections etc as required 55 200 Amp, 25 KA, TP MCCB 56 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415V TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200A, tinned copper bus bar, common neutral link, earth bar, din bar for mountingMCBs (but without MCBs and incomer) as required 57 12 way, (4 + 36) double door 58 Supplying and fixing 5 amps to 32 amps rating, 240v/ 415v, C curve, miniture circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connection, testingand commissioning etc. As required 59 single pole (Modular Type) 60 Single pole and neutral 61 Double pole 62 Tripple pole 63 Tripple pole and neutral 64 supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connetion, testing and commissioning etc. as required. 65 40 amps 66 63 amps 67 supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connetion, testing and commissioning etc. as required. 68 40 amps 69 63 amps 70 Supplying and fixing DP sheet steel enclosure on surface/Recess alongwith 25/32 Amp. 240 volt c curve DP MCB complete with connection, testing, commissioning et. As required. 71 Supplying and fixing TP sheet steel enclosure on surface/Recess alongwith 16/25/32 Amp. 240 volt c curve TP MCB complete with connection, testing, commissioning et. As required. 72 Supplying nd Fixing 20 A, 240V SPN Industrial type socket outlet, with 2 pole and Earth metal enclosed plug top along with 20 A, C curve SP MCB in sheet steel enclosure, on surface or in recess. With chain metal cover for the socket outlet and complete with connections, testing, commissionimng etc. as required. 73 Supplying nd Fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and Earth metal enclosed plug top along with 30 A, C curve TP MCB in sheet steel enclosure, on surface or in recess. With chain metal cover for the socket outlet and complete with connections, testing, commissionimng etc. as required. 74 Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size in existing RCC / HUME / METAL pipe etc. As required. 75 upto 35 sq mm 76 Above 35 sq mm and upto 95 sq mm 77 Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size in existing masonry open duct as required etc. As required. 78 upto 35 sq mm 79 Above 35 sq mm and upto 95 sq mm 80 Laying and fixing of one number PVC inslulated and PVC sheated/ XLPE power cable of 1.1KV grade of following size on wall surface as required. 81 upto 35 sq mm (clamped with 1mm thick saddle) 82 Above 35 sq mm and upto 95 sq mm(clamped with 25x3mm MS flat clamp) 83 Above 95 sq mm and upto 185 sq mm(clamped with 25/40x3mm MS flat clamp) 84 Erection of metalic pole of following length in cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregated 40 mm nominal size) foundtion including exvation and refilling etc. as required. 85 Above 4.5 Meter and uopto 6.5 Meter 86 Providing and making steel pole collar with cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregated 40 mm nominal size) of specified size and shape including form work, plastering if required, quring etc. as required. (Volume of pole/ pipe not to be deducted) 87 Supplying and embedding following dia G.I Pipe (medium class) in pole collar/ foundation during casting for cable entry including bending the pipe to the rquired shape complete as required. 88 32 mm dia 89 Supplying and fixing 32/40 mm dia x 2.00 meters long G.I pipe (meidum class) bracket for mounting of fiuorscent/ HPMV/ HPSV street light fitting on pole including bendingshape, 2 nos. 40 mmx 3mm flat iron clamps with nuts, bolts andthe pipe to the require washer, painting the flat iron primer and finish piant etc as required. 90 Dismentaling of pole/ street light standred sturt embedded in cement concrete foundation et. As required. 91 Excavation for cable trenches in soft soil depth upto 1.2 m including dressing of sides lift upto 1.5 m, including getting out the excavated soi, refilling with sand or good soil after laying of cable/pipe etc. in layers of 20 cm, ramming watreing and disposal of surplus excavated soil as directed, witinh a lead of 50 meters. 92 Supplying and laying of following sizeDWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming toIS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 93 63 mm dia (OD-63 mm & ID-51 mm nominal) 94 Supplying, installation, testing and commissioning of Passive Infrared (PIR) technology base occupancy sensor having high preformance, non regulating programmable type, suitable for connected load upto 10A, for mounting height up to 2.8 meter and 5 meter diameter coverage area along with necessary fixing arrangements i/c programming at site complete as required. 95 Supplying, installation, testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars/ Lighitng DBs for automatic switching On & OFF of street lights at sun set & sun reise or twilight (Auto ON,OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required. 96 1 out put per phase suitable for single phase supply 97 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, earthing et. complete s required. 98 Supply of labour for attending day to day complaints complaints of electrical maintenance work for repair and replacement of all electrical accessories in non workingelectrical fittings and fixture (such main boards, fans, geysers switches, sockets, light fittings, motors, starters, street light, energy meters in lab buildings, underground and overhead line distribution network including service main, operation and maintenance 33KV 044KV substation and power house (24 hour round the clock) all other electrical work as assigned by site-incharge. 99 Skilled labour in Electrical trade 100 Unskilled labour in Electrical trade 101 Attending day to day complaints of no light/ non working points / providing temporary connections in IIP lab buildings, hostel & guest house etc as required. 102 Supplying of RJ45 outlet information module in exsiting modular box etc as required. 103 Supplying of Industrial Heavy duty exhaust fan of 380 mm sweep 1400 rpm/Turboforce neo SP, HD suitable for 230v 50hz ac supply complete with blade, regular, frame and moving system etc as required .The same will be inspected and aproved by Engineer-in-charge before its dispatch from factory to site. 104 Supplying ofexhaust fan of 300 mm sweep 1400 rpm/Ventil air sweep suitable for 230v 50hz ac supply complete with blade, regular, frame and moving system etc as required .The same will be inspected and aproved by Engineer-in-charge before its dispatch from factory to site. 105 Supplyingof following size ISI marked PVC insulated and PVC sheathed/XLPE /FRLS aluminium conductor steel armoured alumimium cable of 1.1KV grade as required. 106 2 X 16 sqmm 107 Supplying following rating 415/230v C series, miniture circuit breaker suitable for lighting and other load of following poles in the existing MCB DB complete with connection, testing and commissioning etc as required 108 Double pole, 63 amps 109 Tripple pole and neural, 63 amps 110 Supply and fabrication of sheet steel MCB enclosure fitted with din rail for MCB of following rating complete with connections including drilling holes etc as required. 111 Double pole enclosure 112 Four pole enclosure 113 Supply and replacemant of capacitor of ceiling fans/ exhaust fan/ wall fan/ padestal fan of size of 2.5 to 4 mfd etc as required 114 Supply & replacement of 16 Amp. Plug top, 3 pin with indigator etc. as required 115 Supply & replacement of 6 Amp. Plug top, 3 pin with indigator etc. as required. 116 supply of following Decorative MIRROR LIGHT 20 W with smart, contemporary design of mirror light . The design is a harmonious blend of curves and angles with frame and inbuilt electronic driver & led luminare etc. as required. 117 20W LED, 6500 K luminaries with tube rod. 118 Supplying of following General purpose industrial compact batten suitable for single or twin LED Tube light with integral LED driver, available in single / double side connection options with all as required. Fixture size: (LxWxH) in (1233x36x46) mm (for 1x22 W), (1233x71x46) mm (for 2x22 W) 119 1 X 4 X 22W LED batten 120 2 X 4 X 22W LED batten 121 Supplying of following high efficiency LED tube rod lamps LED luminaire in existing fitting fixture with connection etc. as required. 122 4 X 20W LED luminaries tube rod. 123 supply of indoor recess/ surface 600X600mm (2X2) LED luminaire 36 Watt, 6500 k with high luman package etc as required.The product features special glare cut optics to ensure low luminaire luminance and is perfect for general and office lighting applications such as workstations, meeting rooms and cabins,corridors and break areas.(Havells/ Wipro/ Philiphs/ c&s) The same will be inspected and aproved by Engineer-in-charge before its dispatch from factory to site. 124 Supplying of 25 Watt, 6500K new generation LED post of lanturn light luminare IP 65, energy saving, enviornmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium lad scape luminaire with high power LEDs as light souce. Clear cover offers bright illumination for different application. (Havells/ Wipro/ Philiphs/ c&s). The same will be inspected and aproved by Engineer-in-charge before its dispatch from factory to site. 125 S/R of following Watt LED strret luminaire, New genration energy savin and enviornmental friendly long life LED street light made uo of pressure die cast aluminium housing with high efficiency LED s lighting source and Toughened glass having bottom opening seperate driver compartment with IP 66 protection and impact Resistance of IK07. (Bajaj/ Havells/Philiphs/WIPRO). The same will be inspected and aproved by Engineer-in-charge before its dispatch from factory to site. 126 30 W led luminaire 127 Supplying of Surface/Recess Mounting LED Panel fitting fixture 15 W( 1X 1), Elegantly designed sleek recessed mounted pressure die- cast alumium luminaire in powder coated white finish in square profile with optimized heat sink for efficient heat dissipation and indepndent elctronic LED driver with connection all etc as required. The same will be inspected and aproved by Engineer-in-charge before its dispatch from factory to site. 128 Supplying and drawing folowing size of PVC insulated Aluminium flat twin core weather proof cabe in existing pipe or surface etc as required. 129 2x6sq mm 130 Supplying of Wall fan of 400 mm sweep, 5 STAR ,energy saving, decorative swing model( off white) suitable for 230 V, single phase, 50 Hz supply including all etc…as required. (Havells/Bajaj/Usha).The same will be inspected and aproved by Engineer-in-charge before its dispatch from factory to site. 131 Supplying of 50 W turbo LED FLOODLIGHT luminaure, Energy saving, enviornmental friendly, long life, one desig for aesthetic consistancy in multi purpose application with SMD LEDs as light source with driver included, suitable for highliting architectural features or area lighting. also suitable to rough services/ installations.( Bajaj/ Philiphs/Havells/Wipro).The same will be inspected and aproved by Engineer-in-charge before its dispatch from factory to site. 132 Providing 9 watt retrofit LED bulbs for guest house etc…as required. 133 Supply of GI electrical pole straight pole of overall length upto 6 meter having two steps and dimensions of 80 mm x 60 mm and pole thickness is 3.65 mm x 3.25 mm for fixing street light complete with M.S base plate having 6.00 mm thickness and with one meter welded tubalar bracket for mounting light fixture all etc. as required. (Detailed pole structure will be as per drawing and aproved by Engineer-in-charge before its dispatch from factory to site).
Contract Date : Ref. Documents   |   Contract Value : Ref. Documents
BRR : 10497935 Tender For Annual Maintenance Contract Of Lab Buildings Of Iip. ( Electrical Works ) 2022-23. -Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5Sqmm Frls Pvc Insulated Copper Conductor Single / Multi Core Cable In Surface / Recessed Steel Conduit Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point / With 1.5Sqmm Fr Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit ( Akg / M-Key ) , With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. 2 Group-A 3 Wiring For Circuit / Submain Wiring Along With Earth Wire The Following Sizes Of Fr Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit ( Akg / Plaza / Kaliga ) As Required 4 2 X 1.5 Sq Mm + 1X 1.5 Sq Mm Earthwire 5 2X2.5 Sq Mm + 1X2.5 Sq Mm Earth Wire 6 2X4 Sq Mm +1X4 Sq Mm Earth Wire 7 2X6 Sq Mm + 1X6 Sq Mm Earth Wire 8 4 X 4 Sq Mm + 2X 4 Sq Mm Earth Wire 9 Supplying And Drawing Following Sizes Of Fr Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. ( Havells / Polycab ) 10 3 X 1.5 Sq Mm 11 3 X2.5 Sq Mm 12 3 X 4 Sq Mm 13 3 X 6 Sq M 14 Supplying And Drawing Following Pair 0.5 Mm Dia Frls Pvc Insulated Annealed Copper Conductor, Unarmored Telephone Cable In The Existing Surface / Recessed / Pvc Conduit As Required. 15 2 Pair 16 Supplying And Fixing Of Following Sizes Of Steel Conduit Along With Accessories In Surface / Recessed Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. ( Akg / M-Key ) 17 20 Mm 18 25 Mm 19 Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recessed Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. ( Akg / M-Key ) 20 20 Mm 21 25 Mm 22 Supplying And Fixing Metal Box Of Following Size ( Nominal Size ) On Surface Or In Recessed With Suitable Size Of Phenolic Laminated Sheet Cover In Front Including Painting Etc As Required. 23 100 Mmx 100 Mmx 60 Mm Deep 24 180 Mmx 100 Mmx 60 Mm Deep 25 200 Mmx 125 Mmx 60 Mm Deep 26 Supplying And Fixing Following Piano Type Switch / Socket On The Existing Switch Box / Cover Including Connections Etc As Required. 27 5 / 6 Amps Switch 28 2 Way 5 / 6 Amps Switch 29 15 / 16 Amps Switch 30 3 Pin 5 / 6 Amps Socket Oulet 31 6 Pin 15 / 16 Amps Socket Oulet 32 Supplying And Fixing Following Piano Type Switch / Socket On The Existing Switch Box / Cover Including Connections Etc As Required. 33 5 / 6 Amps Switch 34 2 Way 5 / 6 Amps Switch 35 15 / 16 Amps Switch 36 3 Pin 5 / 6 Amps Socket Oulet 37 6 Pin 15 / 16 Amps Socket Oulet 38 3 Pin 5 / 6 Amps Socket Oulet 39 Supplying And Fixingtwo Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required 40 Supplying And Fixingfollowing Size / Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switch In Recess Etc As Required 41 1 Or 2 Module ( 75 Mm X 75 Mm ) 42 3 Module ( 100 Mm X 75 Mm ) 43 6 Module ( 200 Mm X 75 Mm ) 44 8 Module ( 125 Mm X 125 Mm ) 45 12 Module ( 200 Mm X 150 Mm ) 46 Supplying And Fixing Following Metal Box Of 180Mm X 100Mm X 60Mm Deep ( Nominal Size ) On Surface Or In Recess With Suitable Size Of Phenolic Laminated Sheet Cover In Fornt Including Providing And Fixing 6Pin 5A & 15 A Socket Outlet And 15 A Piano Type Switch, Connection, Painting Etc. As Required . 47 Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess Including Providing And Fixing 6 Pin 5 / 6 And 15 / 16 Amps Modular Socket Outlet And 15 / 16 Amps Modular Switch, Connection Etc. As Required 48 Supplying And Fixing 3 Pin, 5A Ceiling Rose On The Existing Junction Box / Wooden Block Including Connection Etc As Required 49 Providing And Fixing Plain 16 / 0.20Mm ( 0.50Sqmm ) Twin Flat Flexible, Frls Pvc Insulated, Copper Conductor Cable, In Pvc Sleeve Of Suitable Size On The Floor / Wall, Or Side Of The Table / Door Etc. As Required. 50 Installation, Testing And Commissioning Of Pre-Wired Fluorescent Fitting / Compact Fluorescent Fitting Of All Types, Compelete With All Accessories And Tube Etc.Directly On Ceiling / Wall, Including Connection With 1.5 Sq Mm Fr Pvc Insulated Copper Conductor, Single Core Cable And Earthing Etc. As Required. 51 Installation, Testing And Commissioning Of Ceiling Fan, Including Wiring The Down Rod Of Standrand Lenght ( Up To 30Cm ) With 1.5 Sq.Mm Fr Pvc Insulated, Copper Conductor, Single Core Cable Etc. As Required 52 Installation Of Exhaust Fan In The Existing Opening, Including Making Good The Damage, Connection, Testing, Commissioning Etc As Requied Upto 450 Mm . 53 Supplying And Drawing Of Utp 4 Pair Cat 6 Lan Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 54 1 Run Of Cable 55 Providing And Fixing Following Rating And Breaking Capacity Mccb In Existing Cubical Panel Board Including Drilling Holes In Cubical Panel, Making Connections Etc As Required 56 200 Amp, 25 Ka, Tp Mccb 57 Supplying And Fixing Of Following Ways Surface / Recess Mounting, Vertical Type, 415V Tpn Mcb Distribution Board Of Sheet Steel, Dust Protected, Duly Powder Painted, Inclusive Of 200A, Tinned Copper Bus Bar, Common Neutral Link, Earth Bar, Din Bar For Mountingmcbs ( But Without Mcbs And Incomer ) As Required 58 12 Way, ( 4 + 36 ) Double Door 59 Supplying And Fixing 5 Amps To 32 Amps Rating, 240V / 415V, C Curve, Miniture Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connection, Testingand Commissioning Etc. As Required 60 Single Pole 61 Single Pole And Neutral 62 Double Pole 63 Tripple Pole 64 Tripple Pole And Neutral 65 Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connetionx, Testing And Commissioning Etc. As Required. 66 40 Amps 67 63 Amps 68 Supplying And Fixing Following Rating, Four Pole, 415V, Isolator In The Existing Mcb Db Complete With Connection, Testing And Commissioning Etc. As Reqired. 69 40 Apms 70 63 Apms 71 Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In Existing Rcc / Hume / Metal Pipe Etc. As Required. 72 Upto 35 Sq Mm 73 Above 35 Sq Mm And Upto 95 Sq Mm 74 Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In Existing Masonry Open Duct As Required Etc. As Required. 75 Upto 35 Sq Mm 76 Above 35 Sq Mm And Upto 95 Sq Mm 77 Laying And Fixing Of One Number Pvc Inslulated And Pvc Sheated / Xlpe Power Cable Of 1.1Kv Grade Of Following Size On Wall Surface As Required. 78 Upto 35 Sq Mm ( Clamped With 1Mm Thick Saddle ) 79 Above 35 Sq Mm And Upto 95 Sq Mm ( Clamped With 25X3mm Ms Flat Clamp ) 80 Above 95 Sq Mm And Upto 185 Sq Mm ( Clamped With 25 / 40X3mm Ms Flat Clamp ) 81 Supplying And Fixing 32 / 40 Mm Dia X 2.00 Meters Long G.I Pipe ( Meidum Class ) Bracket For Mounting Of Fiuorscent / Hpmv / Hpsv Street Light Fitting On Pole Including Bendingshape, 2 Nos. 40 Mmx 3Mm Flat Iron Clamps With Nuts, Bolts Andthe Pipe To The Require Washer, Painting The Flat Iron Primer And Finish Piant Etc As Required. 82 Supplying And Laying Of Following Sizedwc Hdpe Pipe Isi Marked Along With All Accessories Like Socket, Bend, Couplers Etc.Conforming Tois 14930, Part Ii Complete With Fitting And Cutting, Jointing Etc.Direct In Ground ( 75 Cm Below Ground Level ) Including Excavation And Refilling The Trench But Excluding Sand Cushioning And Protective Covering Etc., Complete As Required. 83 63 Mm Dia ( Od-63 Mm & Id-51 Mm Nominal ) 84 Supplying, Installation, Testing And Commissioning Of Passive Infrared ( Pir ) Technology Base Occupancy Sensor Having High Preformance, Non Regulating Programmable Type, Suitable For Connected Load Upto 10A, For Mounting Height Up To 2.8 Meter And 5 Meter Diameter Coverage Area Along With Necessary Fixing Arrangements I / C Programming At Site Complete As Required. 85 Supplying, Installation, Testing And Commissioning Of Astronomical Time Switch Of Following Configuration To Be Mounted In Feeder Pillars / Lighitng Dbs For Automatic Switching On & Off Of Street Lights At Sun Set & Sun Reise Or Twilight ( Auto On, Off, Auto Modes ) With Manual Override Facility With 12 / 24 Hour Display Format With Suitable Battery And Indication For Relay Status I / C Programming At Site Complete As Required. 86 1 Out Put Per Phase Suitable For Single Phase Supply 87 Supply Of Labour For Attending Day To Day Complaints Complaints Of Electrical Maintenance Work For Repair And Replacement Of All Electrical Accessories In Non Workingelectrical Fittings And Fixture ( Such Main Boards, Fans, Geysers Switches, Sockets, Light Fittings, Motors, Starters, Street Light, Energy Meters In Lab Buildings, Underground And Overhead Line Distribution Network Including Service Main, Operation And Maintenance 33Kv 044Kv Substation And Power House ( 24 Hour Round The Clock ) All Other Electrical Work As Assigned By Site-Incharge. 88 Skilled Labour In Electrical Trade 89 Unskilled Labour In Electrical Trade 90 Attending Day To Day Complaints Of No Light / Non Working Points / Providing Temporary Connections In Iip Lab Buildings, Hostel & Guest House Etc As Required. 91 Supplying And Fixing Rj45 Outlet Information Module In Exsiting Modular Box Etc As Required. 92 Supplying And Fixingmodular Surface Mount Box With Modular Plate For Telephone Wiring With Telephone Deluxe Jack Single Outlet On Surface Or In Recessed Etc As Required. 93 Supplying, Fixing And Commissioning Of Heavy Duty Exhaust Fan Of 380 Mm Sweep 900 / 1400 Rpm / Turbojet Sp, Hd Suitable For 230V 50Hz Ac Supply Complete With Blade, Regular, Frame And Moving System Etc As Required .The Same Will Be Inspected And Aproved By Engineer-In-Charge Before Its Dispatch From Factory To Site. 94 Supplying Of Ceiling Fan Of 1400 Mm Sweep, With Heavy Fins , High Quality Engineering, Energy Saving, Decorative Pacer Model ( White / Brown / Lovery ) Suitable For 230 V, Single Phase, 50 Hz Supply Including 600 Mm Long Down Rod And Electronic Regulator Etc…As Required. The Same Will Be Inspected And Aproved By Engineer-In-Charge Before Its Dispatch From Factory To Site. 95 Supplying And Laying Of Following Size Isi Marked Pvc Insulated And Pvc Sheathed / Xlpe / Frls Aluminium Conductor Steel Armoured Alumimium Cable Of 1.1Kv Grade As Required. 96 2 X 16 Sqmm 97 Supplying And Fixing Following Rating 415 / 230V C Series, Miniture Circuit Breaker Suitable For Lighting And Other Load Of Following Poles In The Existing Mcb Db Complete With Connection, Testing And Commissioning Etc As Required 98 Double Pole, 63 Amps 99 Tripple Pole And Neural, 63 Amps 100 Supply And Fabrication Of Sheet Steel Mcb Enclosure Fitted With Din Rail For Mcb Of Following Rating Complete With Connections Including Drilling Holes Etc As Required. 101 Double Pole Enclosure 102 Four Pole Enclosure 103 Supplying And Fixing 8 Module Flush Box Of 210 Mmx 75 Mm Size On Surface Or Recessed With Suitable Size Of 8 Module Front Sheet Cover In Front Including Providing And Fixing 6A, 5 Pin Module Socket 02 Nos And 6-16A, 3Pin Combined Modular Socket 01 No 10 A Sp Mini Mcb -01 No Etc As Required 104 Supplying And Fixing 6 Module Flush Box Of 200 Mm X 75 Mm Size On Surface Or Recessed With Suitable Size Of 6 Module Front Sheet Cover Of Make In The Front Including Providing And Fixing 20A One Way Modular Switch 02 Nos And 6-16 A, 3 Pin Combined Modular Socket 02 No Connecton, Painting Etc As Required. 105 Supply And Replacemant Of Capacitor Of Ceiling Fans / Exhaust Fan / Wall Fan / Padestal Fan Of Size Of 2.5 To 4 Mfd Etc As Required 106 Supply & Replacement Of 16 Amp. Plug Top, 3 Pin ( Crabtree / Anchor ) 107 Supply & Replacement Of 6 Amp. Plug Top, 3 Pin ( Crabtree / Anchor ) 108 Supply And Fixing Of Following Led Energy Saving Surface / Pendent Mounting Led Lamp Fitting With Powder Coated / Batten With In Bulit Electronic Ballast With Decortive End Caps Etc. As Required. 109 1 X 4 X 20W Led Luminaries With Tube Rod. 110 2 X 4 X 20W Led Luminaries With Tube Rod. 111 Supplying And Fixing Following High Efficiency Led Tube Rod Lamps Led Luminaire In Existing Fitting Fixture With Connection Etc. As Required. 112 4 X 20W Led Luminaries Tube Rod. 113 Supplying And Fixing Led Tube Rod 18 Watt 2 Feet Single Side Connection Ultra Bright Led Polycarbonate Tube Rod With High Efficinsyfor Installation In Exiisting Suitable Fittings. 114 Overhauling, Rewinding Oiling Greasing Of Ceiling Fan / Exhaust Fan / Pedsetal Fan / Wall Fan Of Any Size Including Supply And Replacement Of Ball Bearing / Bush Capacitor , Split Pin Rubber Wire, Shaft, Nut & Bolt 2X1.5 Sqmm Copper Connecting Wire, Cleaning Varnishing , Revolving Attechment And Step Regulator With Resistence Of Wall And Pedestal Fan Etc Complete In All Respect As Required. 115 1400 Mm Ceiling Fan Rewinding 116 Supply And Commissioning Of Indoor Recess / Surface 600X600mm ( 2X2 ) Led Luminaire 42W With High Luman Package Etc As Required.The Product Features Special Glare Cut Optics To Ensure Low Luminaire Luminance And Is Perfect For General And Office Lighting Applications Such As Workstations, Meeting Rooms And Cabins, Corridors And Break Areas. ( Havells / Wipro / Philiphs / C&S ) The Same Will Be Inspected And Aproved By Engineer-In-Charge Before Its Dispatch From Factory To Site. 117 Supplying And Fixing 15 Watt, 6000K New Generation Led Post Of Lanturn Light Luminare Ip 65, Energy Saving, Enviornmental Friendly, Long Life Aesthetically Designed With Symmetrical Light Distribution, Spun Aluminium Lad Scape Luminaire With High Power Leds As Light Souce. Clear Cover Offers Bright Illumination For Different Application. ( Havells / Wipro / Philiphs / C&S ) . The Same Will Be Inspected And Aproved By Engineer-In-Charge Before Its Dispatch From Factory To Site. 118 S / R Of Following Watt Led Strret Luminaire, New Genration Energy Savin And Enviornmental Friendly Long Life Led Street Light Made Uo Of Pressure Die Cast Aluminium Housing With High Efficiency Led S Lighting Source And Toughened Glass Having Bottom Opening Seperate Driver Compartment With Ip 66 Protection And Impact Resistance Of Ik07. ( Bajaj / Havells / Philiphs / Wipro ) . The Same Will Be Inspected And Aproved By Engineer-In-Charge Before Its Dispatch From Factory To Site. 119 25 Watt Led Luminaire 120 30 W Led Luminaire 121 Supplying And Fixing Surface / Recess Mounting Led Panel Fitting Fixture 10 W ( 1X 1 ) , Elegantly Designed Sleek Recessed Mounted Pressure Die- Cast Alumium Luminaire In Powder Coated White Finish In Square Profile With Optimized Heat Sink For Efficient Heat Dissipation And Indepndent Elctronic Led Driver With Connection All Etc As Required. The Same Will Be Inspected And Aproved By Engineer-In-Charge Before Its Dispatch From Factory To Site. 122 Supplying And Drawing Folowing Size Of Pvc Insulated Aluminium Flat Twin Core Weather Proof Cabe In Existing Pipe Or Surface Etc As Required. 123 2X 4Sq Mm 124 2X6sq Mm 125 Supplying Of Wall Fan Of 400 Mm Sweep, 5 Star , Energy Saving, Decorative Pacer Model ( White / Brown / Lovery ) Suitable For 230 V, Single Phase, 50 Hz Supply Including All Etc…As Required. ( Havells / Bajaj / Usha ) .The Same Will Be Inspected And Aproved By Engineer-In-Charge Before Its Dispatch From Factory To Site. 126 Supplying And Fixing 50 W Turbo Led Floodlight Luminaure, Energy Saving, Enviornmental Friendly, Long Life, One Desig For Aesthetic Consistancy In Multi Purpose Application With Smd Leds As Light Source With Driver Included, Suitable For Highliting Architectural Features Or Area Lighting. Also Suitable To Rough Services / Installations. ( Bajaj / Philiphs / Havells / Wipro ) .The Same Will Be Inspected And Aproved By Engineer-In-Charge Before Its Dispatch From Factory To Site. 127 Supplying And Fixing Of Monkey Guard Fixtures ( Iron / Steel Cover ) For Protection Of Post Of Lanturns Light Fitting With All As Required. Material Designing Must Be Discussed With Enginer In Charge And Before Supplying Its Design Approval Must Be Taken By Engineer In Charge. 128 Providing And Fixing 9 Watt Retrofit Led Bulbs For Guest House Etc…As Required. 129 Supply, Fixingand Commissioning Of Indoor Recess / Surface 160X160mm ( 1X1 ) A L.E.D. Panel Light 18 Watt Equipped With Motion Sensor, Will Work Only At 3.5 Watt / Go Off When Nobody Is Around The Light. Will Go To 18 Watt At Full Intensity As Soon As Any Motion Occurs Around Light . Saves About 75% Electricity With All Acceossiers Etc. As Required.The Same Will Be Inspected And Aproved By Engineer-In-Charge Before Its Dispatch From Factory To Site. 130 Supply, Fixingand Commissioning Of Indoor Recess / Surface A L.E.D. Panel Light 12 Watt Equipped With Motion Sensor, Will Work Only At 3.0 Watt / Go Off When Nobody Is Around The Light. Will Go To 12 Watt At Full Intensity As Soon As Any Motion Occurs Around Light. Saves About 75% Electricity With All Asseossries Etc. As Required.The Same Will Be Inspected And Aproved By Engineer-In-Charge Before Its Dispatch From Factory To Site.
Contract Date : Ref. Documents   |   Contract Value : Ref. Documents
Disclaimer

We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.

Tender Detail
Website https://prasarbharati.gov.in/pbtenders/
Quantity 0
MSME Exemption No
Tender Type Open Tender
Startup Exemption Click Here
Competitive Bidding NCB
Similar Tenders
TENDER INSIGHTS

858

Electric Tenders
Live
CLICK TO KNOW MAXIMUM WIN

Tell us about your Product / Services,

We will Find Tenders for you

🇮🇳 +91
TenderDetail
Loading tenders