Tender Summary / Eligibility Criteria
Construction Of Admin Bldg. At Icar-Iiab At Garhkhatanga, Ranchi. (Supplying Installation Testing Commissioning Of Duplex Control System For Existing 13 Passenger Lift)
Documents
Download All
No Boq
No Corrigendum
Probable Bidders
AI engine predicts probable bidders to help you bid strategically.
MSME Exception
Technical
Tender involves procurement of high capacity electrical equipment including diaphragm coupling of pump &
motor with 90kW capacity at 2900 RPM. The project scope includes installation, testing, commissioning and
operational handover.
Previous / Similar Result
BRR : 4922994
Bids Are invited for REPAIR OF 03 X Nos of lift [13 PASSENGERS/884 KG LIFT] AT BLDG PADMINI,RAGINI,SAGAR AT NAVAL PARK,VISAKHAPATNAM (RESTRICTED AREA) - 1.M&L for replacement of defective 4 Nos of input/output module,BCD to seven segment microcontroller based logic card in the existing 13 passenger lift controller serving G+9 upper floors including internal wiring,testing and commissioning at 03 lifts at Bldgs Viz.Padmini,Ragini,Sagar at Naval Park Visakhapatnam(i) Input/output module=04 Nos in each lift (ii) BCD to seven segment logic card=01 Nos in each lift2. Repair to defective automatic device by replacing charger card,convertor card,main control microprocessor card,relay board,12V&AH maintenance free sealed battery=01 Nos in each lift3.Replacemnt of full length sensor=01 Nos in each lift Total Quantity : 1
BRR : 4922130
Bids Are invited for REPAIR OF 03 X Nos of lift [13 PASSENGERS/884 KG LIFT] AT BLDG YAMINI,VYASA,VALMIKI AT NAVAL PARK,VISAKHAPATNAM (RESTRICTED AREA) - 1.M&L for replacement of defective 4 Nos of input/output module,BCD to seven segment microcontroller based logic card in the existing 13 passenger lift controller serving G+9 upper floors including internal Wiring, testing and commissioning at 03 lifts at Bldgs Viz.Yamini,Vyasa,Valmiki at Naval Park Visakhapatnam(i) Input/output module=04 Nos in each lift (ii) BCD to seven segment logic card=01 Nos in each lift2. Repair to defective automatic device by replacing charger card, convertor card, main control microprocessor card, relay board,12V&AH maintenance free sealed battery=01 Nos in each lift3.Replacemnt of full length sensor=01 Nos in each lift Total Quantity : 1
BRR : 10155865
Tender For Supply, Installation, Testing And Commissioning Of 01 No X 10 Passengers Lifts (680Kg) At Bsnl Telephone Exchange, Naranpura Ahmedabad (Against Outlived Lifts); Supplying, Installation, Testing and Commissioning of10 Passengers (680 kgs) Lift having rated speed of 1.0 Mtr/Sec serving different floors in the shaft as per details given below.:- [ Location of the lift: BSNL Telephone Exchange, Naranpura, Ahmedabad ] :- 1) Type of Lift : Passenger 2) Speed : 1.0 Mtr/sec 3) Travel Height :Ground Floor+05 No4) Stops and Openings : 06 Stops, 06 Openings 5) Rated Load : 680 kg 6) Capacity of Passengers : 10 No7) Power Supply : 415 Volts, 3 Phase, 50Hz AC 8) Controls: Microprocessor based with AC Variable Voltage Variable Frequency with ARD System 9) Full Height Door Sensor 10) Operation: Microprocessor based Controller Duplex Full Selective & Collective 11) Types of Doors: a) Car doors: Power operated, Centre opening, Horizontal Sliding, Stainless Steel, Scratch Proof, Auto doors. b) Landing doors: Power operated, Centre opening, Horizontal Sliding, Stainless Steel, Scratch Proof, Auto doors. 12) Over Load Function with audio-visual indication in Car Operating Panel 13) COP Panel and Hall Button are LED panel14) Door Operated system with V3F drive 15) Music System 16) Voice Annunciator System17) Main Rope – Usha Martin Make18) Over Speed Governor Rope – Usha martin19) Emergency Light and Push & Talk system20) Auto ON/OFF Blower for Lift Car 21) Fire Man Switch 3 Dismantling of existing 1 No. 10 Passanger lift (680 kg) from the existing Lift well incl all acceesoreies, fittings, machinary from the m/c room and make the space available to install a new lift,incl loading & unloading of dimantled material and keep the materials as directed by Engineer In.Charge
BRR : 9139129
Tender For Replacement Of 2 Nos 8 Passenger Lift At Anna Road Telephone Exchage, Chennai; 1 Part A Sitc Of 8 Passenger Lift 2 A ) Supplying, Installation, Testing, Commissioning ( Sitc ) Of8 Passenger Lift Of Capacity ( 544 Kg ) ( Gearless ) For G+7 Floorsat Bsnl Te Anna Road, Chennai, Having A Contract Speed Of 1.0 M / Sec Suitable To Work On 3Phase, 400 / 440 Volts Ac Supply Comprising Of Equipments Including Microprocessor Based Vvvf Drive, Car, Controller, Counter Weight, Self Levelling Devices, Control Devices, Car Position Indicators, Battery Operated Alarm Bell / Emergency Light, Stainless Steel Finished Car Interior, Doors, Self Levelling Devices, Control Devices, Terminal Buffers, Pit Ladder, Ropes, Safety Devices, Car & Landing Push Buttons, Floor Announcer Including Infra-Red Curtain, Automatic Emergency Rescue Device, All Wiring Connections, Interconnections, FiremanS Switch, Including All Equipment In The Existing Hoistway And Miscellaneous Items Like Supports, Etc., I / C Scaffolding, Minor Building Works, Making Good The Same Etc, Conducting Tests, Offering Lift For Inspection By Lift Inspector, Liaisoning With The Inspector Officeetc. Complete As Per Detailed Specifications / Standard Designing According To Site Conditions Conforming To The Latestlift Act And Modern Lift Practice As Required. 3 ( I ) Floors: Ground +7 Floors ( Ii ) Travel :35.07 Metres ( Approx ) ( Iii ) Stops & Opening: 8 Nos ( All On Same Side ) ( Iv ) Controller : Microprocessor Based Ac Variable Voltage & Variable Frequency ( V ) Automatic Rescue Device Complete With Dry Maintenance Free Batteries Of Suitable Capacity. ( Vi ) Operation:- Microprocessor Based Simplex Selective Collective Control With / Without Attendent ( Vii ) Type Of Doors:Car Door : Power Door Centre Opening, Horizontal Sliding , Stainless Steel Scratch Proof ( Moon Rock Finish ) Landing Door : Power Door Centre Opening, Horizontal Sliding , Stainlesssteel Scratch Proof ( Moon Rock Finish ) / Ms Doors Finished With Spray Painting Of Approved Shade B ) A Hand Rail Not Less Than 600 Mm Long At 900 Mm Above Floor Level To Be Fixed Adjacent To The Control Panel In Lift Car. C ) Voice Announcement System In The Car To Announce The Position Of The Elevator In The Hoist Way As The Car Passes Or Stops At A Floor Served By The Elevator.Complete As Above 4 Part B: Buy Back If Existing Old Lifts 5 Less Amount Towards Buyback Of Existing 1 No Life Expired M / S Johnson Limited Lifts Make 8 Passenger ( 544 Kg ) Lift At Anna Road Te, Chennai ( In As Is Where Condition ) Including Dismantling All The Lift Equipments Like Car, Counter Weight, Self Levelling Devices, Control Devices, Doors, Terminal Buffers, Ropes, Safety Devices, Sensors With All Wiring Connections, Interconnections And Miscellaneous Items Like Supports For Guide Rails, Removing / Cleaning Debris Left Out In Lift Shaft / Lift Room, Making Good Damages Etc As Required ( Under Buy-Back Arrangement - Base Value Is Rs.1, 18, 000 / - Including Gst Per Lift. The Agency May Quote Higher. However If The Quoted Value Isbelow The Base Value Then The Base Vaule Is Taken As Final Quoted Value )
BRR : 9749428
Tender For Comprehensive Maintenance Amc Of Lift In Various Lab At M House Area Under Ge I Rnd Delhi; 1 comprehensive maintenance (Routine, preventive, periodical and breakdown) of Passenger/goods/service Lifts installed in following bldgs at METCALFE HOUSE Complex JCBareaas mentioned here-in-after, in reliable, safe and efficient manner using latest techniques & expertise through OEM by regularly examining, lubricating and adjusting the mechanical and electrical driving equipments/componentents, governor sleeve, shaft assembly, bearing/contact, governor jaws, car & hall mechanical push buttons, car & hall position indicators, car direction indicators, car and landing door drive/sensor and all other car and landing signal/ fixtures, deflectors, car and counter weight guide rails and bufferstravelling cable etc with and including replacement of defective / spares parts mentioned in BOQ/Sch - A as supply only and replacement of all kind of defective / spares parts other than mentioned in BOQ/Sch - A i.e. car/landing door sill, lift coil, lever bell crank, fuse holder, transformer, rack harness, guide shoe, light shield, any type of diode panel, push button assembly guide operator, kit door, bush bearing, copper contacts, line brakes, sight guard, any type of glass for hall button, emergency light, fireman control switch/ glass, announcement system, all type of safety, mounting sundrise, wire, lugs, nut, bolts, screws, lubricant, gear oil, aircord, landing wheel, aircord wheel, all types of control cards/logic cards, rewinding of motors(Main & Doors) etc and all machine works i.e. welding, cutting, drilling etc or any other parts/components which is not includ above as and when required to keeping the lifts in serviceable conditions round the clock (on all days including holidays) and during all weather/climate conditions to the entire satisfaction of Engineer-in-charge, complete all as directed for following Lifts. 2 Goods cumpassnger slift of capacity1500 KG with traveling speed of upto 1.0 mtrs/sec,(Ground +6 floors) installedOLD SAG LAB atM House including all instruments and controls complete all as specified and directed. (Make of Lift- Skylark). 3 Passenger lift of capacity 06 Passenger(408 Kgs) with traveling speed of upto 1.0 mtrs/sec, (Ground +5 floors) installed atOLD SAG LAB atMHouseincluding all instruments and controls complete all as specified and directed.(Make of Lift- Thyssen Krupp). 4 Passnager lift of capacity20 passangers forwith traveling speed of upto 1.0 mtrs/sec, six floors (Ground + 5 floors) installed at SAG Lab at MHouse including all instruments and controls complete all as specified and directed.(Make of Lift- JOHNSON). 5 passnger lift of capacity08 passangers (544 KG) with traveling speed of upto 1.0 mtrs/sec, (Ground + 5 floors) installed at DESIDOC `A Block Building MHouse including all instruments and controls complete all as specified and directed.(Make of Lift- Thyssen Krupp). 6 Passengerlift of capacity08 passangers (408 KG) with traveling speed of upto 1.0 mtrs/sec,(Ground + 5 floors) installed at DESIDOC `A Block Building MHouse including all instruments and controls complete all as specified and directed.(Make of Lift- Thyssen Krupp). 7 Passanger lift of capacity05 passangers (408 Kgs) with traveling speed of upto 1.0 mtrs/sec,(Ground + 5 floors) installed at DESIDOC `B Block Building ofMHouseincluding all instruments and controls complete all as specified and directed. (Make of Lift- Thyssen Krupp). 8 Passengerlift of capacity08 passangers with traveling speed of upto 1.0 mtrs/sec,(Ground + 4 floors) installed at CEPTAM LAB at MHouse including all instruments and controls complete all as specified and directed.(Make of Lift- Schindler). 9 Passengerlift of capacity 08 passangerswith traveling speed of upto 1.0 mtrs/sec, (Ground + 4 floors) installed at CEPTAM LAB at MHouse including all instruments and controls complete all as specified and directed. (Make of Lift- Schindler). 10 Passenger lift of capacity08 passangers(544Kgs) with traveling speed of upto 1.0 mtrs/sec, (Ground + 5 floors) installed at ISSA LAB at MHouse including all instruments and controls complete all as specified and directed. (Make of Lift- OTIS). 11 Passengerlift of capacity08 passangers(544Kgs) with traveling speed of upto 1.0 mtrs/sec, (Ground + 5 floors) installed at ISSA LAB at MHouse including all instruments and controls complete all as specified and directed. (Make of Lift- OTIS). 12 Passengerlift of capacity 13 Passengers (844 KG) with traveling speed of upto 1.0 mtrs/sec, (G +6 Floor) installed atBhaskar Building MHouseincluding all instruments and controls complete all as specified and directed.(Make of Lift- OTIS). 13 Passengerlift of capacity 13 Passengers (844 KG) with traveling speed of upto 1.0 mtrs/sec, (G +6 Floor) installed atBhaskar Building MHouseincluding all instruments and controls complete all as specified and directed. (Make of Lift- OTIS). 14 Service lift of capacity200 KG for two floors (Ground + 1 Upper floor) with traveling speed of upto .5 mtrs/sec,through OEMinstalled at LASTEC wet canteen atMHouse including all instruments and controls complete all as specified and directed. (Make of Lift- JOHNSON) . 15 Passenger lift of capacity 10 Passenger with traveling speed of upto 1.0 mtrs/sec, G +4 Floor (Basement + Ground +3 floors) installed atJCB BLDG No-01 in MHouse including all instruments and controls complete all as specified and directed. (Make of Lift- OTIS). 16 Passengerlift of capacity10 Passenger G +4 FloorLiftwith traveling speed of upto 1.0 mtrs/sec, (Basement + Ground +3 floors) installed atJCB BLDG No-02 in MHouse including all instruments and controls complete all as specified and directed. .(Make of Lift- OTIS). 17 Goods cumpassengerLiftof capacity 1000 Kgswith traveling speed of upto 1.0 mtrs/sec, G +4 Floor (Basement + Ground +3 floors) installed atJCB BLDG No-01 in MHouse including all instruments and controls complete all as specified and directed. (Make of Lift- UTL). 18 Takingout existing unserviceable hoist steel wire rope after disconnecting from counter weight pulley and car cabin and supply & fix new steel wire rope 13 mm dia, ungalvanised 8/19 construction, conforming to IS-14665 including making necessary connection with weigh, pully and car cabin GI clamps, nuts, bolts, washers etc,complete all as specified and directed. 19 Taking out existing unserviceable hoist steel wire rope after disconnecting from counter weight pulley and car cabin and supply & fix new steel wire rope 10 mm dia, ungalvanised 8/19 construction, conforming to IS-14665 including making necessary connection with weigh, pully and car cabin GI clamps, nuts, bolts, washers etc complete all as specified and directed. 20 Taking down carefully existing old false ceiling with fan grill & LED up to 08 passenger lift from existing and supply & fixing new false ceiling made of 1.2mm thick stainless steel with hair line finish (N-304) fitted with aluminium square fan withgrill & 10/12 watt LED at 4 Nos, complete all as specified and directed. 21 Taking down carefully existing old false ceiling with fan grill & LED 13 passanger and supply & fixing new false ceiling made of 1.2mm thick stainless steel with hair line finish (N-304) fitted with aluminium square fan withgrill & 10/12 watt LED at 4 Nos, complete all as specified and directed. 22 Takingout existing old unserviceable control panelupto 08/13 passenger existing lift after disconnected all electrical and control wiring connection carefully and supply, installation, testing and commissioning new control panal withmicroprocessor based AC variable voltage variable frequency (ACVVVF) drive close loop. The lift controller shall be wall/floor mounted, vertical, totally enclosed cubicle type with hinged doors on the front and/or the rear to provide easy access to all components in the controller. The cubicle shall be well ventilated such that the temperature inside never exceeds the safe limits of the components at ambient room conditions in the machine room. The controller shall operate within the supply voltage variation of plus 10% to minus 10% of the nominal voltage. An inbuilt voltage stabilizer shall be provided in the controller for the purpose. The controller shall be complete with relay protection against the following: Over current Under voltage Single phasing Phase reversal Earth leakage Over voltage – 3Phase Spikes & Surges Control panels & drive systems shall be designed to meet the requirements laid down by the EN12015 standards relevant to Electro-Magnetic Compatibility (EMC). Lift motor control system shall be electronic closed-loop control to ensure fail safe motor over speed controls and stopping accuracy of ± 3 mm to ± 5 mm. Load compensation circuits shall also be included to further improve upon the levelling accuracy. The levelling shall be ensured within ± 3 mm to ± 5 mm. An Automatic Phase reversal device shall be provided on the controller which shall be designed to protect the lift equipment against phase reversal and phase failure. The controller shall be designed to cut off the power supply, apply the brake and bring the car to a rest in the event of any of the above failures occurring. System should automatically restart when power is restored. System memory should be retained in the event of power failure or disturbance. Lifts should not go in to correction mode or correction run to the lowest floor / highest floor to update its position & memory. The controlled panel should be compatiable as per existing controlled system and should be recommended as per OEM of existng Lift complete all as specified and as directed. Note: Cotractor Shall be submitted techanical data sheet of Control panel before prorcurement for approval. 23 Takingout existing defective unserviceable main drive (any type) from existing control panel and supply & fixing new variable voltage, variable frequency drive (VVVF)upto 15 KW suitable for EXISTING LIFTand including making necessary electric connection, complete all as specified and directed. 24 Taking out old unserviceable Automatic rescue device (ARD)up to8/10/13 passenger lift with sealed maintenance free (SFM) batteries of 12 volts, up to 18 AH ( 06nos battery) after disconnected all electrical and control wiring connection carefully and supply, installation, testing and commissioning new Automatic rescue device (ARD) . The ARD shall be wall/floor mounted, vertical, totally enclosed cubicle type with hinged doors on the front and/or the rear to provide easy access to all components in the ARD. The cubicle shall be well ventilated such that the temperature inside never exceeds the safe limits of the components at ambient room conditions in the machine room. The ARD shall operate within the supply voltage variation of plus 10% to minus 10% of the nominal voltage. An inbuilt voltage stabilizer shall be provided in the ARD for the purpose. The ARD shall be complete with relay protection against the following: Over current Under voltage Single phasing Phase reversal Earth leakage Over voltage – 3Phase Spikes & Surges. The ARD should be automatic evacuation to the nearest floor during power failure or other emergencies. All necessary wiring cable and Connectors connections for proper integration with the lifts control system. The ARD should be working correctly and integrating it with the lifts overall existing control system and should be recommended as per OEM of existng Lift complete all as specified and as directed. Note: Cotractor Shall be submitted techanical data sheet of Control panel before purcurment for approval. 25 Taking out existing old defective door sensor and supply & fixing new sensor with 3D INFRA RED safety edge with power unit on car door to safeguard passenger entering and leaving the liftsuitable for 08/10/13/20 passenger capacity lift complete all as specified and directed. 26 Taking out existing unserviceableground floorLOP up to 20 passenger cum goodslift assembly after disconnected all electrical and control wiring connection carefully and supply & fixing new car operating assembly with and including illuminated push button for floor position, alarm, nonstop, door stop, door close, cabin fan, cabin light stop, attendant out key etc, direction indicator of 7 segment display with SPI card on stainless steel face plate duly controlled and electric connection, also including necessary wiring for laminated push button of each floor, cutting wall, making good the surfaces to match with the existing surfaces, suitable forGoods/Passenger lift. complete all as specified and directed. 27 Taking out existing unserviceableTop floorLOP20 passenger cum goodsliftassembly after disconnected all electrical and control wiring connection carefully and supply & fixing new car operating assembly with and including illuminated push button for floor position, alarm, nonstop, door stop, door close, cabin fan, cabin light stop, attendant out key etc, direction indicator of 7 segment display with SPI card on stainless steel face plate duly controlled and electric connection, also including necessary wiring for laminated push button of each floor, cutting wall, making good the surfaces to match with the existing surfaces, suitable forGoods/Passenger lift. complete all as specified and directed. 28 Taking out existing unserviceable LOP 1st foor tofifth floor up to 20 passenger cum goodslift assembly after disconnected all electrical and control wiring connection carefully and supply & fixing new car assembly with and including illuminated push button for floor position, alarm, nonstop, door stop, door close, cabin fan, cabin light stop, attendant out key etc, direction indicator of 7 segment display with SPI card on stainless steel face plate duly controlled and electric connection, also including necessary wiring for laminated push button of each floor, cutting wall, making good the surfaces to match with the existing surfaces, suitable forGoods/Passenger lift. complete all as specified and directed. 29 Taking out existing unserviceable COP8/10/13 passenger cum goods (G+)lift assembly after disconnected all electrical and control wiring connection carefully and supply & fixing new car operating panel (COP) assembly with and including illuminated push button for floor position, alarm, nonstop, door stop, door close, cabin fan, cabin light stop, attendant out key etc, direction indicator of 7 segment display with SPI card on stainless steel face plate duly controlled and electric connection, also including necessary wiring for laminated push button of each floor, cutting wall, making good the surfaces to match with the existing surfaces, suitable forGoods/Passenger lift. complete all as specified and directed. 30 Taking out existing unserviceable cabin fan and supply & fixing new cabin fan, non-oscilating type, axial flow, single speed, 250mm to 300mm sweep, 240 volt, with grill, complete all as specified and directed. 31 Taking out existing light fittings fromliftcabinand in lieu S & F New LED light fittings,complete with and including LED 10/12 watt, all accessories, fixutres complete all as specified and directed. 32 Taking out existing light fittings fromlift Shaft and in lieu S & F New LED light fittings, complete with and including LED 10/12 watt, all accessories, fixutres complete all as specified and directed. 33 Taking out existing old/ defective PVCflooring matand S & F NewantistaticPVC flooring 3mm thick flame resistance UV coating with superior qualityandthickness of mat 3 mm dully solution/adhesiveafter scraping ,cleaning surface preparing of old surface andcolour/design of mat shal be approved by Engr-in -chargea complete all as specified and directed . 34 Taking down existing unserviceble batteries from machine room and supply & fixing new sealed maintenance free (SFM) batteries of 12 volts, 07AH and making necessary connections with and including copper lead to connect brass terminals of batteries, complete all as specified and directed. 35 Taking down existing unserviceble batteries from machine room and supply & fixing new sealed maintenance free (SFM) batteries of 12 volts, 12 AH and making necessary connections with and including copper lead to connect brass terminals of batteries, complete all as specified and directed. 36 Taking down existing unserviceble batteries from machine room and supply & fixing new sealed maintenance free (SFM) batteries of 12 volts, 18 AH and making necessary connections with and including copper lead to connect brass terminals of batteries, complete all as specified and directed. 37 Note : (For Serial No 01 to 20) The entire work mentioned in this BOQ/Sch - A. Item No. 1 to 17 including comprehensive, preventive and periodical maintenance of lifts / elevators shall be got executed through OEM or any reputed lifts manufacturer i.e. M/s Thyssen Krupp Elevator (India) / M/s OTIS Elevator India Pvt Ltd/ M/s Schindler (India) /M/s OTIS/M/s Johnson/M/s UTL, M/s Skylark only. The contractor shall upload / submit the scanned copy of MOU for AMC (inclusive of material) with lifts manufacturer, as mentioned above, item No. 1 under BOQ item ser for BOQitem No 1.01 to 1.16alongwith his application. The contractor shall also have to submit hard copy of MoU with his application.The lifts will be handed over to contractor in as and when condition and no claim in this effect will be accepted at any stage.The cost of all kind of replaced defective parts/spare /control cards/oil/ lubricants etc, other than mentioned in BOQ/Sch A, as and when required to making the lift/elevator fully functional, is deemed to be included in quoted rates and no extra cost shall be paid to the contractor in this effect. Hence, the bidder is advised to visit the site to assess the quantum of work to be carried out in this contract and quote thier rates accordingly. 38 The comnrehensive /preventive (periodical maintenance includes weekly fortnightly, monthly, quarterly, half yearly inspection/testing as per service manual or as per IS standard. The inspection / test report will be submitted to Engineer-in-charge.The complete records of replaced spare parts, other than mentioned in BOQ/SchA, will be maintained and will be produced to Engineer-in-charge on monthlybasis or as and when asked to produce the same.The complete records of replaced spare parts, other than mentioned in BOQ/SchA, will be maintained and will be produced to Engineer-in-charge on monthlybasis or as and when asked to produce the same.All the complaint(s) will be addressed within 02 hrs from the time of receipt ofcomplaint. If, contractor or his tradesmen fails to attend the complaint within 02 hrs from the time of receipt of complaint, the compensation/penalty of Rs. 500.00 (Rupees Five Hundred only) per complaint per hr for first 04 hrs and after that Rs 1000 00(Rupees One Thousand Only) per complaint per hr shall be recovered from the contractors dues. The cost of transportation (to and fro) and other necessary equipment shall be arranged / brought by contractor to complete the job and no extra cost shall be paid to the contractor in this effect.All the complaints are required to be rectified within 24 hrs or within stipulated time given by the JE/Engineer-in-Charge, if, contractor of his tradesmen fails to rectify the defects, the compensation of Rs. 1000.00 (Rupees one thousand only) per complaint for each date (i.e. 24 hours) shall be recovered from the contractors dues. The decision of accepting officer is this regard shall be final and binding.
Disclaimer
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tender Detail
| Website | https://etender.cpwd.gov.in/login.html |
| Quantity | 0 |
| MSME Exemption | No |
| Tender Type | Open Tender |
| Startup Exemption | Click Here |
| Competitive Bidding | NCB |
TENDER INSIGHTS
858
Electric TendersLive
Tell us about your Product / Services,
We will Find Tenders for you