Tender Summary / Eligibility Criteria
Tender For Repairs And Renewal And Painting Of Rcc Overhead Tank At Akashvani Raichur, Karnataka.
Documents
Download All
No Boq
No Corrigendum
Probable Bidders
AI engine predicts probable bidders to help you bid strategically.
MSME Exception
Technical
Tender involves procurement of high capacity electrical equipment including diaphragm coupling of pump &
motor with 90kW capacity at 2900 RPM. The project scope includes installation, testing, commissioning and
operational handover.
Previous / Similar Result
BRR : 8471466
Tender For Repair Work Of Residential Type I Ii Iii Buildings Part Ii - Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes inCement mortar 1:6 (1 cement : 4 coarse sand) DSR no 6.4.2 2 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1 :2:4 (1 cement : 2 coarse sand (zone-Ill) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)DSR 4.1.3 3 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete uptoor above plinth level. DSR 5.22.1 4 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.DSR 15.56 5 12 mm cement plaster of mix :DSR 13.1.2 1:6 (1 cement: 6 fine sand) DSR 6 Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc.complete DSR No 13.88 7 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surfac eto prepare the surface even and smooth complete. DSR 13.80 8 Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. DSR 13.85.3 9 Distempering with 1st quality acrylic distemper (ready mixed) having VOC(Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour DSR 13.81.1 (two coats) 10 Finishing walls with water proofing cement paint of required shade : DSR 13.109.2 11 Cement concrete flooring 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement sluny, but excluding the cost of nosing of steps etc. complete. DSR 11.3.1 40 mm thick with 20 mm nominal size stone aggregate 12 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1 :4 (1 Cement: 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. DSR 11.37 13 Providing and laying vitrified floor tiles in different sizes (thickness to bespecified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1 :4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. DSR 11.41.2 14 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platfonns, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1 :4 (1 cement: 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing,moulding and polishing of edges to give high gloss finish etc. complete at all levels.DSR 8.2.1.2 Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble 15 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. DSR 10.25.1 16 Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.D.S.R.10.29 17 Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: D.S.R 14.5.1 18 Renewal of old putty of glass panes (length) metre D.S.R 14.9 19 Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as perthe direction of the Engineer-in-charge.DSR 14.85 20 Providing and fixing ISi marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. DSR 9.21.2 30 mm thick including ISi marked Stainless Steel butt hingeswith necessary screws 21 Applying priming coat: With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood DSR 13.50.2 22 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : DSR 13.99 23 Providing and fixing ISi marked oxidised M.S. sliding door bolts with nuts and screws etc. complete (Copper oxidised as per IS 1378) DSR 9.62.1 24 Providing and fixing ISi marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) DSR 9.63 25 Providing and fixing ISi marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete (Copper oxidised as per IS 1378) DSR 9.66.1 26 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,DSR 12.41 (110 mm pvc pipe 27 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.DSR 18.7 (15 mm pvc pipe) 28 Providing and fixing brass bib cock of approved quality.DSR 18.15 29 Providing and fixing brass stop cock of approved quality .D.S.R.18.16 30 Providing and fixing uplasticised PVC connection pipe with brass unions : .D.S.R.18.21.1 31 Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings : DSR 17.25.5 Flat back wash basin of size 450x300 mm 32 Providing and fixing P.V.C. waste pipe for sink or wash basin includingP.V.C. waste fittings complete. 17.28.1 33 Dismantling W.C. Pan of all sizes including disposal of dismantled materials including malba all complete as per directions of Engineer-in-Charge. 34 Providing and fixing white vitreous china water closet squatting pan (Indian type) :DSR 17.13.2 Orissa pattern W.C. pan of size 580x440 mm 35 Providing and fixing white vitreous china pedestal type (European type/wash down type) water closet pan. 36 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. DSR 17.16A 37 Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittingsand fixtures complete.DSR 17.18 38 Disconnecting damaged overhead/terrace PVC water storage tank of any size from water supply line and removing from the terrace includingshifting at ground level as per direction of Engineer-in-charge. DSR 14.79 39 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.D.S.R.18.48
BRR : 8471467
Tender For Repair Work Of Residential Type Iv Buildings Part I - Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes inCement mortar 1:6 (1 cement : 4 coarse sand) DSR no 6.4.2 2 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1 :2:4 (1 cement : 2 coarse sand (zone-Ill) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)DSR 4.1.3 3 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete uptoor above plinth level. DSR 5.22.1 4 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.DSR 15.56 5 12 mm cement plaster of mix :DSR 13.1.2 1:6 (1 cement: 6 fine sand) DSR 6 Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc.complete DSR No 13.88 7 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surfac eto prepare the surface even and smooth complete. DSR 13.80 8 Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. DSR 13.85.3 9 Distempering with 1st quality acrylic distemper (ready mixed) having VOC(Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour DSR 13.81.1 (two coats) 10 Finishing walls with water proofing cement paint of required shade : DSR 13.109.2 11 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade DSR 13.112.1 12 Cement concrete flooring 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement sluny, but excluding the cost of nosing of steps etc. complete. DSR 11.3.1 40 mm thick with 20 mm nominal size stone aggregate 13 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1 :4 (1 Cement: 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. DSR 11.37 14 Providing and laying vitrified floor tiles in different sizes (thickness to bespecified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1 :4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. DSR 11.41.2 15 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platfonns, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1 :4 (1 cement: 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing,moulding and polishing of edges to give high gloss finish etc. complete at all levels.DSR 8.2.2 Granite stone slab of colour black, Cherry/Ruby red 16 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. DSR 10.25.1 17 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. D.S.R.9.135.1 18 Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: D.S.R 14.5.1 19 Renewing glass panes, with wooden fillets wherever necessary:D.S.R 14.6.1 20 Supplying and fixing new wooden fillets wherever necessary: D.S.R 14.8.1 21 Renewal of old putty of glass panes (length) metre D.S.R 14.9 22 Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as perthe direction of the Engineer-in-charge.DSR 14.85 23 Providing and fixing ISi marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. DSR 9.21.1 35 mm thick including ISi marked Stainless Steel butt hingeswith necessary screws 24 Applying priming coat: With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood DSR 13.50.2 25 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : DSR 13.99 26 Providing and fixing ISi marked oxidised M.S. sliding door bolts with nuts and screws etc. complete (Copper oxidised as per IS 1378) DSR 9.62.1 27 Providing and fixing ISi marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) DSR 9.63 28 Providing and fixing ISi marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete (Copper oxidised as per IS 1378) DSR 9.66.1 29 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,DSR 12.41 (110 mm pvc pipe 30 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.DSR 18.7 (15 mm pvc pipe) 31 Providing and fixing brass bib cock of approved quality.DSR 18.15 32 Providing and fixing brass stop cock of approved quality .D.S.R.18.16 33 Providing and fixing uplasticised PVC connection pipe with brass unions : .D.S.R.18.21.1 34 Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings : DSR 17.25.2 35 Providing and fixing P.V.C. waste pipe for sink or wash basin includingP.V.C. waste fittings complete. DSR 17.28.1 36 Dismantling W.C. Pan of all sizes including disposal of dismantled materials including malba all complete as per directions of Engineer-in-Charge. DSR 14.82 37 Providing and fixing white vitreous china water closet squatting pan (Indian type) :17.13.2 Orissa pattern W.C. pan of size 580x440 mm DSR17.13 38 Providing and fixing white vitreous china pedestal type (European type/wash down type) water closet pan. DSR 17.15 39 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. DSR 17.16A 40 Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittingsand fixtures complete. DSR 17.18 41 Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. pan. DSR 17.22 42 Disconnecting damaged overhead/terrace PVC water storage tank of any size from water supply line and removing from the terrace includingshifting at ground level as per direction of Engineer-in-charge. DSR 14.79 43 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.D.S.R.18.48
BRR : 8762559
Tender For Maintenance And Repair To External Water Supply And External Electric Supply, External Street Lights And Connected Work At Ebs Babugarh Under Ge (North) Meerut Cantt.; 1 M&L for laying andtesting 20 mm bore GI tubing medium grade with all required fittings and fixtures laid in trenches, on the ground or on supports or fixed to walls incl taking up or down old unsv pipe making good of disturbed surfaces of roads, path ways etc. complete all as specified and directed. 2 All as per Srl item No 1 but 25mm bore complete all as specified and directed. 3 All as per Srl item No 1 but 40mm bore complete all as specified and directed. 4 All as per Srl item No 1but 50mm bore complete all as specified and directed. 5 M&L for laying andtesting 150 mm bore DI pipes with spigot and socket ends centrifugally cast class K7 in any length suitable for and including tyton joints laid in trenches including necessary cut to length to match the existing fitting / pipes incl taking up or down old unsv pipe making good of disturbed surfaces of roads, path ways etc. complete all as specified and directed. 6 All as per Srl item No. 6 but 100mm bore complete all as specified and directed. 7 All as per Srl item No. 6 but 80mm bore complete all as specified and directed. 8 M&L for taking up or down 80 to 150 mm bore Cast Iron water mains (including all fittings), with spigot and socket ends and lead joints cleaning the pipes free from sedimentation / scaling etc. and re-laying the same in trenches, on the ground or on supports or fixed to walls incl testing complete all as specified and directed. 9 Note for item No 1 to 9 :- Earth work shall be measured and paid separately. 10 Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for laying of Cable or Pipe, electric pole, stay assembly etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/ losse soil complete all as specified and as directed. 11 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. in soft/ losse soil complete all as specified and as directed. 12 Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting pointin soft/ losse soil complete all as specified and as directed. 13 M&L forhorizontal boring for road crossing for laying upto 200 mm bore water supply pipe lines across under roads, foot path etc. and making good disturbed areas as beforecomplete all as specified and directed. 14 M&L for lead joint and testing for 80 to 100 mm bore CI/DI pipe including spun yarn etc. for spigot & socket pipes and fittings complete all as specified and directed. 15 All as per Srlitem No. 14 but 150mm bore complete all as specified and directed. 16 M&L for CI or DI fittings for spigot and socket pipes such as bends (any type, radius and angle), tapers any type (straight, bend, increasing, decreasing or double socket etc), tee pieces, D clamps, angle branch, cross (all sockets or socket & spigot collars, caps and plugs for joining up to 200 mm bore CI pipe in repairs complete all as specified and directed. 17 S&F and testing, 80mm dia CI non rising type sluice valve both ends flanged with CI body, ISI marked, IS 14846, pressure PN 1.6 with brass spindle with clamps and check nuts, operating hand wheel including dismantle and remove the unserviceable sluice valve complete all as specified and directed. 18 All as per Srlitem No. 17 but 100mm bore complete all as specified and directed. 19 All as per Srlitem No. 17 but 150mm bore complete all as specified and directed. 20 Supply and fix Dual plates CI wafer type Non Return / Check Butterfly valve, 100 mm bore tested to pressure of 15Kg/Sqcm flanged type including necessary heavy duty gasket, G I Bolts, G I Nuts, G I Washers etc. incl taking down old u/s complete all as specified and directed. 21 All as per Srlitem No. 20 but 150mm bore complete all as specified and directed. 22 M&L for dismantling of defective 80 mm dia sluice valve for repairssuch as repacking stuffing box of sluice valve spindle, refacing, grinding, stuffing and threading of spindle, replacement of worn out check nut, repairs to gate assembly replacement of jointing materials such as rubber sheets, nuts, bolts & washers, gland rope and refixing in its original position, testing on completion etc. complete all as specified and directed. 23 All as per Srlitem No. 22 but 100mm bore complete all as specified and directed. 24 All as per Srlitem No. 22 but 150mm bore complete all as specified and directed. 25 S&F and testing, 20 mm bore, gun metal gate valve / ball valve, ISI marked, hand lever / iron wheel head operated, screwedat both ends for iron pipes and fixed including taking down of old unsv gate valve complete all as specified and directed. 26 All as per Srlitem No. 25 but 25mm bore complete all as specified and directed. 27 All as per Srlitem No.25 but 40mm bore complete all as specified and directed. 28 All as per Srlitem No.25 but 50mm bore complete all as specified and directed. 29 S&F CPVC Ball valve 50mm OD alongwith necessary leak proof CPVC paste / gum incl taking down old u/s complete all as specified and directed. Make Astral / Supreme / Finolex 30 All as per Srlitem No.29 but 40mm bore complete all as specified and directed. 31 All as per Srlitem No.29 but 32mm bore complete all as specified and directed. 32 All as per Srlitem No.29 but 25mm bore complete all as specified and directed. 33 Supply & laying in trenches / floor or fixed to wall / roof using suitable size MS Clamps duly painted, CPVC pipes SDR 11 and incl plain CPVC SDR 11 fittings of size 50mm OD alongwith necessary leak proof CPVC paste / gum incl taking down old u/s complete all as specified and directed. 34 All as per Srlitem No.33 but 40mm bore complete all as specified and directed. 35 All as per Srlitem No.33 but 25mm bore complete all as specified and directed. 36 M&L for repair / rectification of leakages in water supply distribution GI lines of 20 to 25 mm dia incl necessary excavation, returning filling as per site requirement, tightening of loose joints of GI unions, elbows, sockets, tees etc. cutting / threading if required all as directed.Note:The complaints for the above work are to be collected by the contractor rep from MES maint incharge of EBS Babugarh on daily basis and trades men are to be detailed immediately. Required stationery such as complaint register, Job cards etc shall be arranged and maintained by the contractor. Transport and Tools required for attending the complaints are to be arranged by the contractor. 37 All as per Srlitem No.36 but GI tubing 40 to 50 mm dia complete all as specified and directed. 38 M&L for attending break down of water supply pipe line and repair to CI / DI water mains of size 80 mm to 150 mm dia at a given notice including necessary excavation, earth work by manual or using special T&P such as JCB etc. dewatering from the trenches by using pumps or any other mode, rectification of leakages, fixing of CI specials such as collars bends / tail peaces / D-clamp joints etc. and arresting the leakage, testing all as directed. Note: Specials, joint materials only measured and paid separately. 39 M & L for Construction of brick masonry valve chamber of size 1000 x 1000 x 1000 mm (Internal dimenssions) with PCC foundation 1:4:8 type D2 using 40 mm graded stone aggregate 150 mm thick, 150 mm wide off sets allround over 100 mm thick hard core, brick masonry walls built in CM 1:6, 50 mm thick PCC 1:2:4 Type B1 coping finished even and smooth, rendering 10 mm thick in cement mortar (1:6) finished even and smooth, with out using extra cement internally and 150mm below GL externally and top of floor including excavation, earth work in soft / loose soil, 5 mm thick MS sheet cover fixed on 50 mm x 50 mm x 6 mm thick angle iron frame with hold fasts embedded in PCC coping with locking arrangement, mild steel handle and painting to steel surfaces with two coats of synthetic enamel paint over one coat of red oxide primer including disposal of surplus soil to a distance not exceeding 50 m etc. complete all as specified and directed. 40 All as per Item No. 39 but of size 600x600x600 complete all as specified and directed. 41 M&L for cleaning of 100000 Gallon RCC over head reservoir of any type, any height using construction of staging or by mechanical means for carrying out the inner surface of the walls and ceilings of the tank shall be cleaned with high pressure jet pump after emptying the water in the tank. After thorough cleaning of the tank, the cleaning water and sludge is to be removed by using pump and the sludge has to be disposed off at a place as directed. After removing thesludge from tank, the tank shall be cleaned thoroughly by using high pressure water pump first and again cleaned the tank by using high pressure vaccume pump and after removing the sludge / dirt completely from the tank the floor and inner surfaces of the tank shall be cleaned by using a industrial vaccum cleaner and the tank shall be made fully dust free. After made the tank dirt free the inner surfaces of walls and ceiling of the tank shall be treated with anti bacterial agents. After the treatment as mentioned above, the inner surface of walls and ceiling shall be treated with UV Radiator. After complete treatment is carried out, the all pipes inlet, over flow, delivery, wash out, ladder and doors shall be painted with two coats of synthetic enamel black paint after thorough cleaning the surfaces and also the surfaces of sluice valves shall be painted with PO red paint and writing Capacity of tank, date of cleaning and due date of cleaning on wall as specified and as directed. Incl replacing of u/s wire mesh of ventilations of the tank with new mesh complete all as directed BY Engineer-in-Charge.Notes for item No : (1) The unit rate quoted deemed to be including draining of water with mechanical equipment and working in water and mud etc. (2) The unit rate quoted deemed to be include all safety precautions which shall be taken while working on RCC over head tank / under ground sump and contractor or his engineer shall be available during execution of the job. (3) Lightning arrangements if required to be provided by the contractor temporarily at his own arrangements and the amount quoted for that is deemed to be inclusive in the unit rate and electricity/ diesel shall not be provided by MES. 42 Disconnecting the suction and delivery pipe line and electric connections of submersible pump set 25 / 30 HP and removing it from its original position alongwith pipes and fittings carefully by using chain pulley and tripod, transporting the same to the authorised work shop for necessary maint / repairs and refixing the same in its original position after repairs by lowering along with pipes including connecting up of water and electric connections including testing andcommissioning complete all as specified. (Depth of bore welll is upto 50 Mtr). Note: Expendable stores like cotton waste / cleaning materials, lubricants, gland packing, metal filling, machining and transportation to and from site to work shop and labour element are deemed to be included in rate quoted. 43 M&L for rewinding ofthesubmersible motor with super enamelled Copper conductor of good quality, same gauge and same No. of turns as that of existing including tying the winding and connecting the coils and bringing the connections as that of existing complete all as specified including applying insulating varnish, heating and backing the windings thoroughly for submersible motor 25 / 30 HP capacity. 44 M&L for Opening theSubmersible pumpset up to 30 HP pump sets for inspection, repairs and reassembling the pump and motor as per the original assembly after repairs / replacing the worn out unserviceable parts with new parts as ordered, including cleaning replacing the minor items like packing bolts, nuts washers and MS clamps etc and applying one coat of approved hammertene spray paint on exposed steel surface, making the pump and motor fully serviceable and testing after refixing and commissioning all as directed for satisfactory operation on its full load. Note: Spare parts will be measured and paid under relevant item separately. All minor consumables / Eqpt / Tpt required shall be deemed as included in the rates quoted. 45 Supply only Motor bearing, bush complete set inlet/outlet side suitable for submersible pump set up to 30 HP capacity complete all as specified and directed. 46 All as per Srlitem No.45 but Impeller complete all as specified and directed. 47 All as per Srlitem No.45 but Pump NRV complete all as specified and directed. 48 All as per Srlitem No.45 but SS sleeves complete all as specified and directed. 49 All as per Srlitem No. 45 but Neck ring stage casing complete all as specified and directed. 50 All as per Srlitem No.45 but Sand guard complete all as specified and directed. 51 All as per Srlitem No.45 but Oil seal complete all as specified and directed. 52 All as per Srlitem No.45 but Bowel case complete all as specified and directed. 53 All as per Srlitem No.45 but stainless steel shaft of standard size complete all as specified and directed. 54 S&F in repairs, flexible submersible cable 3 core 10 Sqmm with stranded Copper conductor, 1100 volts grade,PVC insulated, PVC sheathed, connecting with necessary end ferrules / water proof joints complete all as specified and directed. 55 S&F in repairs, fully automatic star delta motor starter suitable for 25 / 30 HP submersible pumpset, 3 phase, 415 V with relay range of 45 to 75 Amps incl enclosure complete all as specified and directed. . Make - Havells/Schneider/L&T 56 Supplying, installing, erecting, testing and commissioning, factory made and tested, pump panel board outdoor type, dimensions not less than 1.0 m (L) X 0.5 m (W) X 1.2 m (H), suitable for 3 phase, 415 Volts, 50 Hz system with 200 Amps capacity aluminium bus bar. The panle should be dust and vermin proof, IP 56 class protection and made of 3.15 mm thick CRCA MS sheet with doble door, both sides openable inclusive of locking arrangement, suitable opening for vent and cable entry consisting of Electronic fully automatic star delta starter-01 No. having automatic phase sequence corrector, programmable time with input supply by MCCB of 100 Amps rating, digital type Ammeter and Voltmeter, selector switch, CTS, RYB including indication lampsetc, suitable for submersible pump-motor set of size 25/30 HP, erected on 50X50X6mm thick angle iron frame work, bottom channel of size: 70X40X5 mm powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside , grouted in floor including complete earth work such as excavation, removing and returning filling and required PCC work for the erection of the panel board, complete all as specified and as directed. 57 S&F in repairs, Pressure Gauge, 100mm dia, 0 - 14 Kgs rating complete all as specified and directed. 58 Supply of Calcium hypochlorite having 65% to 70% strength chlorine for disinfection purpose in white coloured powder form for water treatment in sealed non returnable containers in the store yard of EBS Babugarh complete all as specified and directed. Make- RENSA/Purichlor 59 M&L for repairs of dosing system consisting of Syntex make 100Ltr capacity poly Ethelene (PE) tank, Fibre reinforced plastic (FRP) lid have port hole for pouring calcium based granual disinfectant chemical and water when necessary and operatedwith 1 phase motor , 240V complete to the satisfactory operation of the system complete all as specified and directed. 60 M&L for the existing Microprocessor based circuit type water level device consist of seven segment 2 LED display fitted in the control panel operated the pump to automatic switch off when the water level in OH tank reaches the maximum level, visual display with audio alarm on low water level in tank complete to the satisfactory operation of the system complete all as specified and directed. 61 M&L for Structural Steel Work, made out ofFe 410-W (Gde-E-250) quality-A Rolled Mild Steel Channel, Angle or Tee Sections, MS sheet with hinges & locking arrangementsetc. cut to shape / ordinary length, drilled and countersunk for Screws / Bolts, including bending and welding duly painted with 2 coats of Anti Corrossive Synthetic enamel paint over a coat of Zinc Chromate complete all as specified and directed. 62 M & L for carrying out B check of 320 KVA DG set through authorised service dealer of the manufacturer including replacement of B check service kit complete all as per manufacturers standards complete all as specified and directed. 63 All as per Srlitem No.62 but for 50 KVA DG set complete all as specified and directed. 64 All as per Srlitem No.62 but for 15 KVA DG set complete all as specified and directed. 65 M&L for draining out old engine oil, S&F Engine lubricanting oil conforming to the engine manufacturer requirement of classification SAE 15 W 40 lube oil complete all as specified and directed.Make : Servo / Castrol 66 M & L for Overhauling of radiator including dismantling from engine,opening of radiator, cleaning of radiator tubes, fans with acid and removing the scaling & dust, brazing the copper tubes, arresting the leakages completely etc, including renewal of all connecting parts i.e. radiator hose pipe with clamps, bolts, nuts, washers, rubber bush packing material, etc. and re assembling the radiator and fixing with DG set properly in original position, checking the alignment, making proper hose connection, testing for smooth operation complete all as directed for DG set of any type/make having capacity of 320 kVA.NOTE: The cost of renewed parts is deemed to be included in unit rate quoted by contractor. No extra cost shall be paid to the contractor for the same. 67 All as per Srlitem No.66 but for 50 KVA DG set complete all as specified and directed. 68 All as per Srlitem No.66 but for 15 KVA DG set complete all as specified and directed. 69 M&L for taking out injector of DG set of capacity 320 kVA, disconnection and opening of fuel injector assembly, carrying complete overhauling/servicing of fuel injector system, including replacement of injector kit, checking of pressure, complete for each injector and reassembling the same in original positionby making proper fuel connection and testing for smooth operation complete all as specified and directed.Note: Cost of renewal of parts to be measured and paid separately. 70 Supply only nozzle holder for 320 kVA DG set of any make complete all as specified and directed. 71 M&L for opening /taking out fuel injection pump (FIP) of DG set of any type/make of capacity 320 kVA, disconnecting of fuel injector line, carrying out complete overhauling servicing of injector pump, calibration of fuel pump as per manufacturer instruction, assembling of the same wit DG set properly in original position, checking the alignment, making proper fuel connection including renewal of unserviceable/defective minor parts like seal O ring, fuel pump gasket, gear, technometer, bushing, technometer cover, fuel pump, gear housing, fuel pump gear, etc. and testing for smooth operation complete all as directed after renewal of following major parts if found defective/unserviceable.NOTE: The cost of renewed parts is deemed to be included in unit rate quoted by contractor. No extra cost shall be paid to the contractor for the same. 72 Supply only Plunger and return spring for 320 kVA DG set of any make/type complete all as specified and directed. 73 Supply only control rod for 320 kVA DG set of any make/type complete all as specified and directed. 74 Supply only Plunger barrel for 320 kVA DG set of any make/type complete all as specified and directed. 75 Supply only delivery valve and spring for 320 kVA DG set of any make/type complete all as specified and directed. 76 Supply only HP line for 320 kVA DG set of any make/type complete all as specified and directed. 77 Supply only pump element for 320 kVA DG set of any make/type complete all as specified and directed. 78 Supply only roller tappet for 320 kVA DG set of any make/type complete all as specified and directed. 79 Supply only nozzle for 320 kVA DG set of any make/type complete all as specified and directed. 80 Supply & fix flexible coupling for 320 KVA DG Set including alignment of alternator with engine complete all as specified and directed. 81 All as per Srlitem No.80 but50 KVA DG set complete all as specified and directed. 82 All as per Srlitem No.80 but 15 KVA DG set complete all as specified and directed. 83 M & L for alternator servicing, decarbonising the alternator coils, re-varnishing, heating, bearing checking, re-greasing and termination, tinning for 320 KVA DG Set complete all as specified and directed. 84 All as per Srlitem No.83 but for 50 KVA DG set complete all as specified and directed. 85 All as per Srlitem No.83 but for 15 KVA DG set complete all as specified and directed. 86 Supply and filling coolant of superior quality complete all as specified and directed. Make Servo / Castrol 87 M&L for cleaning of diesel tank of DG Set 320 KVAincluding replacement of worn-out pipe line and measuring scale and fixing in original position and make it leak proofwith necessary clamps complete all as specified and directed. 88 Supply and fixing battery 12V 180 AH including replacement of terminals and connecting lead suitable length and size of multi stranded copper wire complete all as specified and directed. .Make:- Exide/Amaron 89 All as per Srl item No.88 but 12V,100 AH complete all as specified and directed. 90 Dismantling of burnt/defective wiring system of DG Set 320 KVA and M&L for complete wiring of required size with sleeves thimbles, lugs etc for DG set complete all as specified and directed. 91 All as per Srlitem No.90 but for 50 KVA DG set complete all as specified and directed. 92 All as per Srlitem No.90 but for 15 KVA DG set complete all as specified and directed. 93 Disconnection and taking out the unserviceable turbo charger assembly of DG Set 320 KVA and taking to workshop, strip opening of turbo charger and replacement of repair kit, re-assembling and fixing back to engine and testing complete all as specified and directed. 94 All as per Srlitem No.93 but for 15 to 50 KVA DG set complete all as specified and directed. 95 M & L for servicing, repairing, maintenance of self starter assembly of DG Set 320 KVA, complete with replacement of switch magnet,bush gear, O ring assembly, bush set, sealing kit, clutch assemble with new ones and refixing the same in original positioncomplete all as specified and directed . NOTE: The cost of replacement of items mentioned in the description is deemed to be included in the rate quoted by the contractor and no extra payement will be done for replacing those items. 96 Supply only armature for 320 kVA DG setcomplete all as specified and directed. 97 Supply only solenoid switch for 320 kVA DG set complete all as specified and directed. 98 Supply only field coil for 320 kVA DG set complete all as specified and directed. 99 All as per Srlitem No 96but for 15 to 50 KVA DG set complete all as specified and directed. 100 All as per Srlitem No 97but for 15 to 50 KVA DG set complete all as specified and directed. 101 All as per Srlitem No 98 but for 15 to 50 KVA DG set complete all as specified and directed. 102 Supply & Replace Fan belt set of existing size complete of DG Set 320 KVAcomplete all as specified and directed. 103 All as per Srlitem No. 102 but for 15 to 50 KVA DG set complete all as specified and directed. 104 Supply & Replace Oil temperature gauge 0-130C complete all as specified and directed. 105 Supply & Replace Water temperature gauge 0-130C complete all as specified and directed. 106 Supply & Replace DC ammeter 0-50 complete all as specified and directed. 107 Supply & Replace Tachometer 0-2500 RPM complete all as specified and directed. 108 Supply & Replace Ignition switch DC with Key complete all as specified and directed. 109 Supply & Replace Oil pressure gauge 0-7 Kg/Cm complete all as specified and directed. 110 Supply & Replace Distilled Water complete all as specified and directed. 111 Supply & Replace Battery lead terminals complete all as specified and directed. 112 S & F automatic battery charger for 12/24V battery complete with all necessary controls and fixing arrangments complete all as specified and directed. 113 S&F in replacement of DG set door lock with handle with double key of all doors of DG set canopy of any capacitycomplete all as specified and directed. 114 S&F in replacement of Automatic voltage Regulator (AVR) suitable for DG Set of320 KVAcapacity with and including taking out old AVR and making all connectiontesting for smooth operation complete all as specified and directed. 115 All as per Srlitem No above here-in-before butfor 50 KVA DG set complete all as specified and directed. 116 Supply, fixing & testing Volt meter 0-500 Volts, 96mm x 96mm, digital type complete all as specified and directed. Make : AE/ Rishab/Meco/Enercon. 117 Supply, fixing & testing Ammeter 0-400 Amps, 96mm x 96mm, digital type complete all as specified and directed. Make : AE/ Rishab/Meco /Enercon. 118 S&F in repairs, thermal over load relay of various ranges starting from 3 Amps to 15 Amps complete all as specified and directed. Make : Type ML0 to ML 1.5 of L&T /BCH/ C & S Electric / Siemens. 119 S&F in repairs, thermal over load relay of various ranges starting from 9 Amps to 42 Amps complete all as specified and directed.Make : Type ML2/ML3 of L&T or equivalent of BCH/ C & S Electric / Siemens. 120 S&F in repairs of single phase preventor, auxiliary volts 415 volts, suitable for 3 phase AC supply complete all as specified and directed. 121 S&F in repairs, testing push buttons with thermo plastic body actuators with carrier having flush type push button complete all as specified and directed.Make : BCH/C & S Electric /L&T / Siemens. 122 S&F in repairs, testing pilot lamps LED type with integral circuit & cluster LED suitable for operating at 240 /220 Volts complete all as specified and directed. Make : BCH/C & S Electric /L&T / Siemens. 123 Preparation of the existing surfaces of electric panels of any description and size & applying two coats of synthetic enamelled paint of approved shade complete including writing details & information on its panels with paints in the pattern & style to match with the words as existing all as directed. 124 M&L for preventive maintenance and servicing of AMF panel of any capacity DG set installed at site incl checking of connections of cables and tightening of loose wiring, nuts and bolts of panel andbus bar chamber. The cost includes minor items like replacement oflugs, control wiring and ferrules etc. complete all as specified and directed. 125 S&F in replacement, asbestos rope of 19 mm dia around of the exhaust pipe of diesel engine any cap complete all as specified and directed. 126 M&L for repair of burnt / perished cable ends on incoming and outgoing feeders of panel equipments and other machinery including cutting of burnt ends preparing / dressing of cables end crimp with suitable size of cable lugs (cable lugs will be measured and paid seperately) incl providing, fixing suitable nuts / bolts / washers etc. forupto 95Sqmm 3.5 core cable 127 All as per Srlitem No.1 but 120Sqmm to 240 sqmm 3.5 core complete all as specified and directed. 128 S&F Al lugs for cable size 50 to 70 sqmm complete all as specified and directed. 129 S&F Al lugs for cable size 95 to 120 sqmm complete all as specified and directed. 130 S&F Al lugs for cable size 240 to 300 sqmm complete all as specified and directed. 131 S&F in replacement,synthetic rubber insulated mats in replacement forinstallations size 2 mtr X 01 mtr X 2.5 mm thick, for voltage upto 11 kV, ISI marked, as per IS 15652-2006 complete all as specified and directed. 132 M&L for repairs of existing On Load/off load Change Over Switch, 4P, 400 Amps, 415 volts by cleaning/ decarbonising,replacement of worn out contacts,lugs and handle arrangement to the smooth function of the item complete all as specified and directed. 133 S&F in repairs of Off load change over switch 4 pole, 415V, AC , 100 A rating with enclosure type complete all as specified and directed. . Make- HPL 134 S&F in repairs, connect,MCCB 4 Pole, 415V, adjustable type, 400 Amps,breaking capacity of 36 KA with cable separators complete all as specified and directed. 135 All as per Srlitem No.9 but 200 Amps, 36KA complete all as specified and directed. 136 All as per Srlitem No.9 but 160 Amps, 36 KA complete all as specified and directed. 137 All as per Srlitem No.9 but 100 Amps, 16 KA complete all as specified and directed. 138 S&F in repairs, connect,MCCB 3 Pole, 415V, 125 Amps, 16 KA complete all as specified and directed. 139 All as per Srlitem No.13 but 63 to 100 Amps, 16KA complete all as specified and directed. 140 Testing and calibration of HT VCB 11 KV complete with primary and secondary test as required including checking of wiring of all electrical measuring instrument and resetting of relay and proper alignment mechanical system for smooth functioning and tripping at any type offault developed in feeders complete all as specified and directed by Engineer-in-Charge. Note:Contractor will submit primary and secondary test record at the time of calibration of HT VCB, duly signed by the technical rep of manufacturer/authorised dealer to Engineer in Charge. The rate quoted by the contractor shall be deemed to include the cost of this provision incl T&P required for injecting regulated high current. 141 Disconnecting of HT supply from 11 KV VCB of any make/type/capacity for repair works, servicing and taking out trolley with completedecarbonizing the contactpoints, cleaning with CRCsolution and inner body clean with vaccum cleaner etc and incl replacement of defective minor parts like lugs, terminals, ferrule,control wiring, nut bolts, HRC fuse links etc found during servicing. Reassembling and testing of relays for trippingtime setting over current setting, earth fault setting etc including checking of vaccume interrupter, tripping mechanism etc after servicing complete all as specified and directed by Engineer-in-Charge. 142 M&L for servicing/repair of VCB spring charging motor 24/220 Volt DC/AC for 11KV VCB, of existing make, type, size, capacity with driving gear including ensuring the manual operation of charging complete testing to the satisfactory operation of VCB charging complete all as specified and directed. Note: (1) HT VCB above servicing shall be carried out only by qualified and experienced person and prior approval shall be obtained from GE.(2) The major spare parts required during above servicing will be measured and paid separately under relevant item of schedule. 143 Supply only open/closed auxiliary contacts suitable for upto 630 Amps HT VCB fixed in repairs. As per existing sample. 144 Supply only under voltage release suitable for upto 630 Amps HT VCB fixed in repairs. As per existing sample. 145 Supply only under/over frequency release suitable for upto 630 Amps HT VCB fixed in repairs. As per existing sample. 146 Supply only Shunt trip closing coil assembly 110/220 volts, DC/AC suitable for upto 630 Amps, HT VCB complete all as specified and directed. 147 Supply only Shunt trip tripping coil assembly 110/220 volts, DC/AC suitable for upto 630 Amps, HT VCB complete all as specified and directed. 148 Supply only spring charging Motor Cut off switch as per existing samplesuitable for 11 KV VCB complete all as specified and directed. 149 M&L for cable jointing kit for 11 KV (Earthed) grade for indoor terminations heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120sqmm to 185 sqmm incl taking out old jointing kit of any make and type complete all as specified and directed. 150 All as per Srlitem No.149 but out door type of size 120 to 185 sqmm HT cable complete all as specified and directed. 151 All as per Srlitem No.149 but out door type of size 95 sqmm HT cable complete all as specified and directed. 152 M&L for cable jointing kit for 1100 volts grade (LT cable) for outdoor terminations heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 240 sqmm to 300 sqmm incl taking out old jointing kit of any make and type all as specified and directed. 153 All as per Srl item No. 152 but for LT cable of size 120 sqmm to 185 sqmm complete all as specified and directed. 154 M&L for laying in repairs of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor, 11000 volts earthed grade of size 95 sqmm 3 core cable laid in trenches/ ducts or fixed to walls / poles or passed through pipes all as directed. 155 All as per Srlitem No.154 but out door type of size 3 core x 120 sqmm complete all as specified and directed. 156 Supplying laying and testing XLPE insulated ,armoured , electriccable (heavy duty)1100 volt grade with stranded aluminium conductor, laid in trenches / ducts or fixed to walls / poles or passed through pipesscomplete all as specified of following sizes :- 157 All as per Srl item No.156 but 240 Sqmm, 3.5 core cable complete all as specified and directed. 158 All as per Srl item No.156 but 120 Sqmm, 3.5 core cable complete all as specified and directed. 159 All as per Srl item No.156 but 95 Sqmm, 3.5 core cable complete all as specified and directed. 160 All as per Srl item No.156 but 70 Sqmm, 3.5 core cable complete all as specified and directed. 161 All as per Srl item No.156 but 50 Sqmm, 3.5 core cable complete all as specified and directed. 162 All as per Srl item No.156 but 35 Sqmm, 3.5 core cable complete all as specified and directed. 163 All as per Srl item No.156 but 25 Sqmm, 3.5 core cable complete all as specified and directed. 164 All as per Srl item No.156 but 16 Sqmm, 4 core cable complete all as specified and directed. 165 All as per Srl item No.156 but 10 Sqmm, 2 core cable complete all as specified and directed. 166 All as per Srl item No.156 but 6 Sqmm, 2 core cable complete all as specified and directed. 167 M&L for fixing PCC cable route markers of size 700X240X75 mm at top of cable trench complete all as specified and directed. 168 Supply and spreading clean fine dry river sand in trenches for cushioning of under ground cable/ cable duct or inside the premises of transformer yard complete all as specified and as directed. Note: Only punned thickness shall be measured for payment purpose. 169 M&L for laying burnt clay fly ash old size bricks, straight or curved on plan, laid flat with width equal to length of brick, laid dry over under ground cable for protection complete all as specified and as directed. 170 M&L for Galvanized steel tubing, light grade, with all fittings for protection of cable including taking down old, rusted & corroded unsv Galvanized steel tubing complete all as specified and as directed of the following sizes:- 171 100mm bore complete all as specified and directed. 172 80mm bore complete all as specified and directed. 173 50mm bore complete all as specified and directed. 174 40mm bore complete all as specified and directed. 175 M & L for cutting hard standing/ Road cutting for taking up or laying of LT UG cable upto a depth of 15 cm and after laying of cable, well ramming to the excavated soil and repair the cutting/ exvcavated portion of road as existing or by providing suitable mixture of PCC complete all as specified and as directed. 176 M&L for providing PCC 1:4:8, type D-2, (using 40 mm graded stone aggregate) as in foundation for erection of poles complete inclding breaking and removing the old concrete complete all as specified and as directed. 177 M&L for providingPCC 1:2:4, typeB-1 (using 20 mm graded stone aggregate) as incoping to pole etc., including breaking and removing the old concrete and providing necessary form work complete all as specified and as directed. 178 M&L for lightning arresters expulsion type complete with all fittings, transmission class, max discharge capacity 65 kA suitable for 11000V grade including taking down existing unsv damaged lightening arrestor complete all as specified and as directed. 179 M&L for switch air break, gang operated, triple pole, mechanically operated, vertical/ Horizontal out door type, mounted on insulators and steel frame with operating mechanism worked from ground level for current rating upto 400 Amps suitable for 11000 volts grade complete all as specified and as directed. 180 M&L for 11000V grade, expulsion type fuses, single pole, mounted on insulators and steel frame of current rating 50 Amps including taking down old unsv expulsion fuse unit complete all as specified and as directed. 181 Surface excavation not exceeding 30 cm deep and averaging 20 cm deep and getting out in soft/ loose soil, removing of bushes, roots etc., in the transformer/ sub station yard and surrounding of two or four pole structres, treating the excavated area with anti vegetation growth chemicals, complete all as specified and directed. 182 M&L for loose filling with aggregates of gauge 40 to 80 mm of broken stone or boulders, deposited, spread and levelled in layers not exceeding 20 cm thick, watered and rammed to a true surface of transformer/ sub station yard and two pole / four polestructure complete all as specified and as directed. 183 Isolating the transformer/ voltage stabilizer by carefully dismantling the HT / LT and earth connections, draining out the oil from transformer to the required level and storing in cleaned container, opening the top cover of transformer/ voltage stabilizer and conservator tank from transformer, rectifying the defects and dismantling & replacing burnt out LT/ HT bushes, making all HT / LT connections as per the original, re-filling the transformer oil to the required level, replacing required oil seals & top cover gasket including replacing rusted unsv nut, bolt & washers and testing on completion and refixing the same for capacity upto 250 KVA complete all as specified and as directed. NOTE: (1) LT/ HT bush, transformer oil for topping up and gasket will be measured and paid separately as supply only items under relevant items of schedule 184 Disconnecting the HT/ LT connection, taking out the transformer/ voltage stabilizer from its plinth at any situation with the help of suitable crane and transporting the transformer/ voltage stabilizer to workshop for carrying out necessary repairs and bringing back and re-install in its original place of capacity upto 250 KVA complete all as specified and as directed. 185 Taking out complete core from transformers/ Voltage stabilizer of capacity upto 250 KVA cutting and removing burnt out copper/ aluminium winding and re-winding the same with super enamelled copper conductor of existing gauge togetherwith insulatingmaterials, applying varnish, drying in heating chamber, re-assembling the transformer as per the original and testing on completion complete all as specified and as directed. NOTE: Shifting of transformers/ Voltage stabiliser from installed position to civil workshop and back will be measured and paid separately under relevant items. 186 M&L for transformer/ voltage stabiliser oil filtration for removing sludge, dust, dirt and moisture from the oil, with the filtered oil having breakdown voltage (BDV) greater than 30 kV (avg) at 2.5 mm gap. NOTE: Contractor will submit BDV test value of the filtered oil after the filtration process duly signed by the technical rep of the manufacturer/authorised dealer to Engineer in Charge. The cost of this provision incl required T&P for getting the oil tested for BDV value is deemed to be included in the rate quoted by the contractor. 187 Supply only transformer oil for topping up in transformers/ Voltage stabilizer complete all as specified and as directed.. Make:Poweroil/Transol GET complete all as specified and directed. 188 Supply only bush of capacity 100 KVA Transformer 11KV/433V type complete all as specified and directed. 189 Supply only bush of capacity 250 KVA transformer 11KV/433V type complete all as specified and directed. 190 Supply only silica gel complete all as specified and directed. 191 M&L for silica gel breather and oil cup, including sufficient quantity of silica gel along with oil filling in the cup if oil level in the cup is not up to the mark, complete all as specified and as directed for thefollowing capacities of transformer:- NOTE: The cost of oil is deemed to be included in the rate quoted by the contractor. 192 Transformer of capacity 100 KVA complete all as specified and directed. 193 Transformer of capacity 250 KVA complete all as specified and directed. 194 M&L for preparation of old painted surfaces of HT 11 KV four pole structure and painting with two coats of aluminium paint over a coat of red oxide primer on all steel surfaces such as poles, channels, angles and clamps of any description and providing 04 Nos bands/ straps with synthetic enamel paint (black and white 30 cm wide each) from top of plinth block complete all as specified and as directed.. 195 All as per item No. abovehere-in-before but of two pole structure complete all as specified and directed. 196 Dismantling damaged steel tubular poles/ struts of any size complete complete all as specified and as directed. 197 M&L for erection of steel tubular, swaged poles complete with cast iron base plate of size 300 x 300 mmfinial taper plug, cap, bolts, nuts, washer and screws as specified confirming to IS type 410 SP-31 (9 M long), providing through hole of 14 mm diameter at a height of 300 mm above the planting depth for earthing arrangements, inclusive of coated with two coats of black bituminous paint throughout internally and externally up to the planting depth and the remaining portion of the exterior shall be painted with two coats of silver aluminium paint over one coat of red oxide primer complete all as specified and as directed. (Note : Excavation, earth work, PCC foundation, coping shall be measured and paid sepearately under relevnt items). 198 M&L for erection of steel tubular, swaged poles complete with cast iron base plate of size 300 x 300 mmfinial taper plug, cap, bolts, nuts, washer and screws as specified confirming to IS type 410 SP-55 (11 M long), providing through hole of 14 mm diameter at a height of 300 mm above the planting depth for earthing arrangements, inclusive of coated with two coats of black bituminous paint throughout internally and externally up to the planting depth and the remaining portion of the exterior shall be painted with two coats of silver aluminium paint over one coat of red oxide primer complete all as specified and as directed. (Note : Excavation, earth work, PCC foundation, coping shall be measured and paid sepearately under relevnt items). 199 M&L for fixing stay assembly having 20 mm diameter of stay rodincluding loop type insulator, stay clamps, etc complete with accessories as shown in electrical plate No. 1 (Excavation and Concrete work will be measured separately) complete all as specified and directed. 200 Releasing the binding of ACSR conductor of LT/ HT OH lines comprising 3 Phase 3/ 4 wire or single phase 2 wire inclduing street light conductor & earth wireof line from insulator, removing the jumper, connector, service wire, disconnecting the connection of UG cables and restreching & stringing of existing LT/HT OH lines, any size, length and span upto desired sag and rebinding the ACSR conductor on insulator, reconnecting the UG cable etc with and including suitable binding/ jumper material with aluminium wire and trimming the tree branches upto 1.5m distance around conductor to make the line functional complete all as specified and as directed. . Note: (a) Jumper/ binding material shall be deemed incldued in the rate quoted by contractor. (b) Trimming of tree branches shall be measured and paid separately under relevant items. (c) Any type conductor and any number of runs between the poles shall be measured as one span for the purpose of payment. 201 Material & Labour for attending break down/ emergent repair immediately on intimation and rectify the External electric supply complaint on LT/HT overhead lines/ under ground cable alongwith necessary T&P, safety devices etc. as per site requirement complete all as specified and as directed for the following:- 202 M&L for jointing of LT/ HT OH line in case of breaking of conductor and refreshing of wornout jumper by suitable jumper/ binding materials complete all as specified and directed. 203 Disconnecting worn out under ground cable from over head conductor, cutting down worn out portion of under ground cable of any type and size for repairs and taking out under ground cable loop from ground by excavating and all neccessary earth work and making fresh connection for restoration of electric supply complete all as specified. Note: Excavation, earth work, taking out cable protection covers, & sand cushion and relaying the same shall be deemed incldued in the rate quoted by contractor 204 Disconnecting worn out under ground cable of any type and size from main switch board/ any type of switch gear system including change over switch etc. for repair and taking out under ground cable loop from ground by excavating and all necessary earth work and making fresh connection by proving suitable size of lugs for restoring of electric supply complete all as specified. Note: Jointing material, Lugs etc and Excavation, earth work, taking out cable protection covers, & sand cushion and relaying the same shall be deemed included in the rate quoted by contractor 205 M&L for ACSR conductor in OH lines of HT/ LT/ street light conductor (Squirrel/ Weasel) including jumper and binding material with aluminium wire complete all as specified and directed. 206 M&L for cradle guard, hexagonal/ rectangular or as per existing shape fabricated with galvanised steel wire 4 mm dia including binding the gaurds with cradle supproting GI wire inclduing taking down existing unsv gaurd wire complete all as specified and as directed. 207 M&L for trimming of tree branches around HT / LT overhead lines including cutting and removing any foreign material like bushes or shurbs complete and removing the trimmed/ cut down branches/ bushes/ shrubs and depositing where directed at a distance not less than 100m complete all as specified and as directed.Note:- (a) The item will be measured in span length. The approx span length is 35M to 50M. (b) The cost for T&P and transportation required shall be deemed included in the rate quoted by contractor. 208 Supply and replace PVC spacers suitable for 2 wire sagged ACSR conductor complete all as specified and as directed. 209 Supply and replace PVC spacers suitable for 4 wire sagged ACSR conductor complete all as specified and as directed. 210 M&L for Pin type, porcelain, vitreous, white, brown or green insulators including one galvanised mild steel spindle, two galvanized iron washers and one galvanized iron nut, 100 mm height, 65mm dia for 1100 volts grade complete all as specified and as directed. 211 All as peritem no. 88 but height 150mm, dia 150 mmm for 11000 volts grade complete all as specified and directed. 212 M&L for shackletype, porcelain, vitreous, white, brown or green insulator includinggalvanised mild steel straps,washers, insulator bolts andnuts, of size 100 mm height, 115mm dia for 1100 volts grade complete all as specified and as directed. 213 All as peritem no. 193 above but size 150mm height,and dia 150 mm for 11000 volts grade complete all as specified and directed. 214 S/F in repairs, 1100 volts grade heavy duty PVC sheathed stranded Aluminium conductor twin core cable flat or circular of size 6 Sqmm complete all as specified and directed. 215 All as per item No 195 above but 10 Sqmm size complete all as specified and directed. 216 M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shapes or size including painted with two coats of silver aluminium paint over one coat of red oxide primer complete all as specified and as directed. 217 Scraping, cleaning and preparation of old surfaces of steel tubular pole (9 Mtr long) steel fitting complete and M&L for painting with one coat for aluminium paint after preparation of the steel surfaces and then applied strap with two coats black & white paint in strap alternatively all round the poles from the bottom of the pole for indication of the poles. Height of the strap shall be 30cm and number of strap shall be 05 Nos and all as directed by Eng-in-Charge 218 S & F in repair MCB SP 6 to 32 A, AC, 240V, 10 KA, ISI marked, either B series or C series, complete all as specified and directed. 219 S & F in repair isolator DP 40 A, AC, 240V, 10 KA, ISI Marked complete all as specified and directed. 220 S & F in repair isolator 4P 63 A, AC, 415V, 10 KA, ISI Marked complete all as specified and directed. 221 Supplying, installing, commissioing and testing of LT switchgear panel board ( Kiosk) of size not less than 600mmx600mmx500mm,IP-55 (outdoor type) , 415 Volts, 50 Hz, AC supply, three phase and neutral ( 4 wire) ,200 Amps coloured horizontal tinned Aluminium bus bars , factory made out of 3.15mm thick MS sheetstructure mounted onrigid mild steel angle iron frame of 50mmx50mmx6mm with 400mm long extended legs grouting in PCC 1:2:4 type B1 of size 150mmx150mmx250mm , duly epoxy powder coated internally and externally with approved shade, rubber gasketted, hinged front double doorand back openable doors with proper locking arrangements for dust and vermin proof ,complete including adjustable thermal and fixed magnetic release MCCB 4 pole, 100 Amps, 415V,36 KA,50 hz-01 No (incoming),suitable size cable allay,lugs , glands and making connections/ wiring with suitable size SC PVC insulated copper conductor cableall as specified. 222 Earthing complete with galvanised MS earth plate of size 600 x 600 x 6mm thick burried directly in ground not less than 2.25 Mtr below ground level, earth plate paced on all side with charcoal mixed with salt to a thickness of 150mm in layers, connected by GI earth strip of size 32 x 6mm thick, soldered and revetted to earth plate. GI earth strip will be protected by using 40mm bore GI pipe (light grade) from test point to main board. The earthing includes PCC pit chamber, RCC pit cover and frame, watering pipe 20mm bore, funnel with wire mesh with necessary earth work including disposal of surplus soil to a distance not less than 50 Mtr etc complete all as specified and shown in electrical plate No 3 of SSR Part-I. (Note : Main earth lead beyond 7.5 metre measured and paid for separately). 223 Earthing complete with galvanised MS earth plate of size 600 x 600 x 6mm thick burried directly in ground not less than 2.25 Mtr below ground level, earth plate paced on all side with charcoal mixed with salt to a thickness of 150mm in layers, connected, soldered and revetted to earth plated / galvanised earth lead wire 4.0mm dia by means of bolts, nuts , check nuts and washers of galvanised iron or steel. GI earth wire will be protected by using 15mm bore GI pipe (light grade) from test point to main board. The earthing includes PCC pit chamber, RCC pit cover and frame, watering pipe 20mm bore, funnel with wire mess with necessary earth work including disposal of surplus soil to a distance not less than 50 Mtr etc complete all as specified and shown in electrical plate No 3 of SSR Part-I. (Note : Main earth lead beyond 7.5 metre measured and paid for separately). 224 Apply proper electric shutdown of the feeder, dismantle and taking down LED street / Security light fitting of any make or modelalongwith connecting cable from elevated height of pole or building for repair by changing LED drive of suitable capacity, thorough cleaning and refixing the same after necessary repairs on its own position connecting complete all as directed. Note:- Spares of security/street light fitting shall be measured and paid under relevent supply only items. Required T & P and labour is deemed to be included in the rate quoted. 225 Supply only LED Driver suitable for any make or model LED street / security light fitting of capacity 25to 35 Watts complete all as specified and directed. 226 All as per item No 206 above but for 36 to 45 Watts complete all as specified and directed. 227 All as per item No 206 above but for 60/72 Watts complete all as specified and directed. 228 Supply only PVC sheathed two core 2.50 Sqmm stranded Aluminium conductor cable flat or round complete all as specified and directed. 229 Supply and fix 35 watts , 230V AC outdoor type (IP-65/66 protection) LED integrated street/security light fitting with all accessories incl connections and testing complete all as specified and directed. 230 All as per item No 210 above but 70 watts LED fitting complete all as specified and directed. 231 Lowering of high mast light assembly from upto 16 Mtr high mast, any make / model, dismantling, checking the serviceability and make the light fittings operational to give rated illumination incl cleaning the glass cover and refixing the same after repair / replacement of defective components complete with necessary electrical connection incl provision of two core 2.5 Sqmm PVC cable with multi stranded Copper conductor of required length, testingcomplete all as directed. Note: Flood light fitting shall be measured and paid separatelyunder relevent item. The cost of greasing of pully, roller, bearing and gear incl refixing of rope clamps , adjustment of lock, leaver, requried T & P and labour etc is deemed to be included in the quoted rate 232 Supply only LED flood light 120 watt, 230V, AC out door type with IP-66 protection with impact and corrosion resistant complete with driver complete all as specified and directed. 233 S&F LED post top light fitting IP 65 rated 20watt to light up parks, gardens and heritage sites complete all as specified and directed. 234 S&F LED bollard pressure diecast powder coated housing with PC diffuser, efficient high output LED 10 wattwith IP 65 protection complete all as specified and directed. 235 S& F in repairs and connect of solar LED street light fittings 20 watt with 40 AH battery bank, PV solar panel fitted on and incl 5 mtr steel pole with base plate incl foundation bolts, braket, clamps , nuts etc complete all as specified and directed. Note- Necesssary excavation/earth work , PCC/RCC work will be measuered and paid under relevant item of schedule. 236 Taking down unsv street light loop-in and loop out box by disconnecting electrical connection and removing existing clamps, nuts, bolts, and washers and supply, fix and connect, factory made out door type syntex street light loop-in and loop out box comprising with suitable size of bus bar, insulators, connectors etc and with one C curve 6 Amp MCB SP, one PVC way connector etc. incl suitable size clamps, nuts, bolts & washers complete all as specified and directed. 237 S&F 3 core , strandedcopper conductor cable 1.5 sqmm, PVC insulated and PVC sheathed , 1100 Volts grade for making connections from junction box tostreet light fittings including PVC conduit of size 20mm dia including necessary clampscomplete all as specified and directed. 238 S/F and connect, factory made duly painted metallic weather proof enclosure street light panel timer unit outdoor type having one 40 Amps C curve MCB TPN, three phase 415 V 32 Amps power contactor, Automatic operation street light timing switch having lighting control (ON-OFF) through Astronomical Calculation of Sun rise / sun set by setting date, time and degree of longitude and latitude without separate light sensors etc. including necessary fixing arrangements, suitable size clamps, nuts, bolts & washers complete all as specified and directed.
BRR : 8558745
Tender For Periodical Services To Ora 300 Line Qtrs At Ina Ezhimala And Comprehensive Maintenance To In Living Qtrs Cb Offers Qtrs Offers Mess Uru And Ettikulum Area.; 1 Notes:-1. Contractor should to purchase minimum 50% of all items mentioned in this BOQ within 15 days from the date of commencemet of work and keep in custody so that no delay in work due to non avilability of materails will be faced. Contractor should ensure during the entire period of work that he has minimum 25% of materials with him till the completion of item/date. 2. Contractor should buy the exact items which are given with Catalogue reference. Other makes will be approved only by submitting non availability certificate from company. Contractor need to remove all the dismantled items without delay after the schedule of credit is removed from the RAR. 3. Rate quoted for demolition/dismantling/ taking down is inclusive of removing the same from site and disposing at given locations anywhere inside INA Ezhimala.4. In any painting works, contractor need to clean the area and remove the drop marks from floors, doors, windows, sills, inbuilt furniture items etc.. Otherwise,a recovery of Rs. 10.00 per sqm in internal paintings and Rs 5.00 per sqm for external paintings will be made from contractor.5. Contractor should maintain seperate registers for plumbing and carpenter repairs works. Day to day complaints should be noted in those registers with Sl nos of complaints, location, qty of work, status of complaints and signature of Incharge and stamp of the Office. Format will be given from AGE B/R 1 Office. Contractor should obtain the signature of incharge on the same day of work. These registers to be submitted to JE(Civil) on every weekend without fail. Also submitted alongwith RAR duly signed.Contd......... 2 Notes...(Contd)...6. List of complaints will be given to contractor as and when received from users and Contractor should ensure all the works will be completed within 48hrs.7. Contractor should ensure that plumbing complaints resulting in wastage of water should be attended and rectified within 24 hours. Otherwise, a recovery of 25 % of corresponding item will be made from contractor for every day delay.8. Contractor will make his own arangement to store his items. 9.Some places in this contract where the vehicle will not reach the spot directly, the material will be moved manually in these places.The rate quoted will be considered all inclusive on this account. 10.All trade skilled labour required in this contract shall be present daily in working hours, irrespective of complaint received.11.Complaint for a similiar items may be in scattered/different area , quoted rate will be considered all inslusive on this account. 12. Empty tins / cans of paint shall not be removed from site till completion of work. 3 Material and labour for preparation of old painted wall surfaces including brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying one coat of exterior emulsion Antifungal paintusing rollers made from foam or synthetic fibres to get a smooth and tint free surfaces complete all as specified and as directed. 4 Rendering 15mm thick on fair faces of brick work or concrete surfaces in patches or narrow widths in Cement mortar 1:4 (Mixed with WPC) to be finished even and smooth without using extra cement including taking down cement plaster of any description on brick wall, ceiling etc. including raking out joints, hacking for key, scrubbing down with water etc. WPC shall be measured and paid under relevant item. 5 Supply only Liquid water proofing compound complete all as specified. Make: ROFFEE HYPROOF of Roffee construction chemicals pvt.ltd/ Conplast PROLAPIN 421 IC of FOSROC chemicals/Pidilite LW+ or equivalent make approved by GE. 6 Material and labour for preparation of old painted steel surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint on steel surfaces all as specified and as directed. 7 Material and labour for preparation of old painted steel surfaces including cleaning of rusting of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. 8 Material and labour for treating holes crackes etc. up to 5 mm making V groove and filling the crackes with ready to use crack fillers and allowed to drycomplete all as specified and as per manufacturer instructions. 9 Material and labour for treating holes cracks etc. more than 10 mm and up to 40 mm and filling the cracks by using flexible2 pack poly sulphide sealants of Berger home shield joint seal GG / PG (Berger make or equivalent ) and allowed to dry complete all as specified and as per manufacturer instructions. 10 Material and labour for complete removal of existing painting/treatment including preparation of surfaces and applying one coat of damp guard of approved manufacturer on exposed surfaces all as per manufacturer instructions(Make : Berger Damp stop advanced / Dr fixit damp guard classic/Asian paints smart care damp proof). 11 Material and labour for preparation of wall surfaces and applying exterior waterproofing wall care putty and finshing the surface even and smooth complete all as specified and as directed. (Make Berger /Asian/Dr fixit) 12 Material and labour for preparation of old treated mangalore pattern roof tile surface by cleaning the surfaces with jet washing and wire brushes to remove all existing fungal, growth etc. and applying one coat of tile guard paint of Asian paints or equivalent tile guard paint complete all as per manufactures instructions.(Make: Berger PU Tile coat/ Asian Paints Tile Guard/Dulux Weathersheid Tile)Note:- The work shall be carried out on upto double storey slopping roof, chajja etc. and contractor is required to make necessary arrangements for water and electricity required for jet washing and rate quoted is deemeed to be included for above. 13 Dismantling single layer of mangolare pattern tiles in roofing complete all as specified and as directed. 14 Refixing roof tiles mangalore pattern interlocking tiles complete all specified and as directed. 15 Material and labour for fixingroof tiles mangalore pattern interlocking roof tiles any size as directed laid dry complete all specified and as directed. 16 Material and labour for complete removal of existing treatment/ preparation of existing surfaces as per site condition and cleaning the surfaces with bio wash to receive new treatment and applying twocoats ofAntifungal/ Weather resistant acrylic exterior emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal/algae resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, coverage@ 6 to 7 Sqm / ltr (two coats) over and including priming coat of exterior primer applied @ 11 Sqm/ltr (for one coat) complete all as specified and as per manufacturer instructions. Make : Berger Weather coat glow/ Asian Paints Apex Ultima/ Dr fixit Rain coat select 17 Material and labour for preparation of old treated surfaces and applying one coat of white wash on wall complete all as specified and as directed. 18 Material and labour for preparation of old treated surfaces and applying one coat of white wash on ceiling complete all as specified and as directed. 19 Material and labour for preparation of old treated surfaces and applying one coat of acrylic emulsion paint on wall (interior grade) all as specified and as per manufactures instructions. 20 Material and labour for preparation of old painted surfaces exc 10 cm width or girth and applying one coat of synthetic enamel paint on wooden surfaces complete all as specified and as directed. 21 Material and labour for preparation of old decorated painted surfaces and applying one coat of synthetic enamel paint on old AC board ceiling complete all as specified and as directed. 22 Material and labour for complete removal of old textured painted surfaces of any description and applying two or more coats textured exterior paint of required shade ,applied @3.28 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm. 23 Taking down cement plaster on brick or stone walls etc including racking out joints, haking for key ,scrubbing down with water,etc. 24 Material and labour for rendering 10 mm thick in CM 1:4 on any faces of brick work or concrete surfacesfinished even & smooth without using extra cement complete all as specified and as directed. 25 Material and labour for Rendering 15mm thick in CM 1:6 on any faces of brick work or concrete surfacesfinished even & smooth without using extra cement complete all as specified and as directed. 26 Material and labour for preparation of new plastered surfaces of any descriptionand applying two or more coats of coats of 100% premium acrylic emulsion paint @ 1.43 ltr / 10 sqm on wall (including priming coat @ 0.9 ltr /10 sqm all as specified and as per manufactures instructions. 27 Material & Labour for preperation of new plastered surface of any description and applying two or more coats ofexterior acrylic emulsion paint having required shade @ 1.67 ltr /10 sqm over a coat of exterior primer @2.2 kg /10 sqm. 28 Material & Labour for preperation of old existing treated plastered surface of any description and applying single coat ofexterior acrylic emulsion paint having required shade. 29 Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. 30 Material and labour for Glazed ceramic coloured tiles 350x250x7mm /450x350x7mm thick in vertical surfaces of stone/brick wall, set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10 mm thick backing coat plaster in CM 1:4 all as specified and as directed. 31 Material and labour for coloured Non-skid ceramic tiles (square/rectangular) 7 to 8mm thick in floors, area of each tile exc.0.06 sqm but n.exc 0.11 sqm, set and jointed in neat cement slurry and pointed in white cement mixed with matching pigment over and including 20mm thick screed bed in CM 1:6 all as specified and as directed. 32 Material and labour for vitrified tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles nt exceeding 0.36 sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and fixed over screed bed 20 mm CM 1:6. 33 All as per item No 31.00 here-in-before but in skirtings. 34 Demolition of Plain cement concretein ground floor and pavings n exc 15 cm thickness (below or above ground level). 35 Material and labour for 75mm thickplain cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in sub bases,plinth protection,floors etc. 36 Material and labour for PCC 1:2:4, 25 mm thick type B0 using 12.5mm graded stone aggregate as in floor finished even and fair with out using extra cement complete all as directed by Engr-in-charge. 37 Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar. 38 Material and labour 20mm thick Granite (of any type) work (table rubbed and polished)in steps, jambs, pillars, window-cills, cooking plat forms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admix ture of pigment to matchwith shade of granite including rounding of exposed edges all as specified and as directed. 39 Demolition of Plain cement concreteof any description and in anypositionnot otherwise specifically provided for complete all as specified and as directed. 40 Material and labour for plain cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete complete as specified and as directed. 41 Dismantling wrought iron , mild/stainless steel ,Aluminium railing work of any description not otherwise provided for 42 Supply and fix rolled sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates conforming to FE-410 - W(grade E-250) quality A all as specified and as directed. 43 Material and labour Hand rails, grills ,Gates ,half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors,balusters,nosing to steps including embeding in concrete and screwing etc. wind ties for roof , Brackets for Valley gutters , including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 410-0 or FE 310-0. 44 Material and labour for preparation of new steel surfaces of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed. 45 Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings below mangalore tiles all as specified and as directed. 46 Supply and fix 0.63mm galvanised corrugated mild steel sheetingwith grade of zinc coating 275 & two corrugations side lap ,fixed with L-type or J-type or cranked hook bolts. 47 Supply and fix Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensilecstrength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and as directed. 48 Supply and fix 0.8 mm galvanised plain mild steel sheeting ,in ridges,hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 , fixed with L-type or J-type or cranked hook bolts. 49 Dismantling single layer Mangalore pattern or similar tiles in roofing. 50 Material and labour roof tiles,Mangalore pattern, interlocking at side joints,laid dry 51 Material and labour ridge or hip tiles to suit Mangalore pattern of roof tiles ,bedded and jointed incement mortar 1:6 including raking cutting and waste to hips into old roofing works. 52 Dismantling wall/floor and ceiling boards (fiber, pulp, inlsulation, blankets) any thickness including covered fillets and supporting members complete all as specified and as directed 53 Material and labour for 6mm dia .G.I. Hangers (upto 1200mm length) adjusting level fixed to rof slabs by means of ceiling cleats made out of GI flat 40 x 3 mm size 60mm long and expansion hold fastners 12.5mm dia. 40mm long complete all as specified and as directed. 54 Material and labour Anodised aluminium snap grid frame work for false ceilingall as specified and as directed. 55 Providing and fixing Gypsum Board 12 mm thick in ceiling fixed with screw as per manufacturers instructions. 56 Taking down chowkats or frames not exc. 1.5 Sqm each but without taking off shutters from the frames. 57 Taking down chowkats or frames exc. 1.5 Sqm but n.exc 4 Sqm each but without taking off shutters from the frames. 58 Taking down shutter of any description exc. 1 Sqm and n. exc 2 Sqm each complete all as specified and as directed. 59 Taking down shutter of any description n exc. 1 Sqm each complete all as specified and as directed. 60 Supply and fix powder coated aluminium frame for doors, windows, ventilators, partitions,kitchen cupboars frame etc with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed (minimum thickness of powder coating not less than 50 micron). 61 Supply and fix Powder coated aluminiumdoor shutters, aluminium section weighing 0.55kg/m incl necessary joining cleats glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges anodised aluminium snap beaking screws etc complete all as specified and as directed. 62 Supply and fix Powder coated aluminium window and ventilator shutters fixed or sliding type without sash bar, aluminium section weighing 0.55 kg/m incl necessary joining cleats rubber packing anodised aluminium snap beading screws etc complete all as specified and as directed. 63 Providing and fixing factory made UPVC white colour casement (Openable) Door with frame made of extruded profile wilh wall thickness of 2.3mm ( + -0.2mm). Window profile with hollow section with multi chamber, frame (60mm x 58mm), sash (60mm x 78mm). T profile (One vertical length in between two shutters) (60mm x 74mm). Glazing/Gauze/Panel bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. Necessary fittings/ builders hardware includes one nos 04 liver locking system with SS double handle ,01 Nos 250mm SS sliding bolts,01 Nos 200 mm SS tower bolt, EPDM gasket 1.2 + -0.2mm thick galvanized steel Frame (28mm x 21.5mm), sash (31mm x 27mm), T profile (27mm x 17mm) to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners. Corner striker. Secondary Strikers. Cylinder. Door transmission gear made of mild steel with multi point locking system with strikes. 3D Hinges of zinc alloyed (white powder coated) and 5mm thick glazing/panells with selected quality glass,wiremesh with necessary rubber beeds to fill up 5mm gap. (Note: The unit rate quoted by contractor excludes cost of glass /wiremesh/Panels and includes all other connected approved accessories such as hinges ,locking system, handles, doorv stoper etc. Net opening will be measured for payment purpose.) 64 Supply and fixaluminium composite panel 4mm thick of approved colour and shade fixed with self tapping screwson aluminium frame work in suitable shape and size complete all as specified and directed by Engr-in- Charge.Note:- Supply and fix aluminium frame work if required shall be measured and paid separately. 65 Supply and fixing 24 mm thick factory made PVC door shutters to existing door frames made of styles and rails of a UPVC hollow section of size 59x24 mm and wall thickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The styles and rails mitred and jointed at the corners by means of M.S. galvanized/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of H section, a uPVC hollow section of size 100x24 mm and 2 mm (± 0.2 mm) wall thickness, fixed to the shutter styles by means of plastic/galvanised M.S. U cleats. The shutter frame filled with a UPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as specified by the manufacturer and as per directions of Engineer- in-charge. (For W.C. and bathroom door shutter) 66 Material and labour 30mm thick, flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, both face is covered with decorative face veneer with lipping/frame to match supplied and fitted to chowkatscomplete all as specified and as directed. 67 Taking down shutter of any description exc 1 Sqm but n exc 2 Sqm each and refixing the same after carrying out repair including easing and adjusting and also refixing builders hardware as required including renewal of unserviceable screws, etc. 68 Supply and fix in repairs 200 mm aluminum alloy anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminum alloy. 69 Supply and fix in repairs 300 mm aluminum alloy anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminum alloy. 70 Supply and fix 100mm mild steel butt hinges, cold rolled medium weight all as specified and as directed. 71 Supply and fix in repairs 150 mm anodised aluminium handles cast type complete all as specified and as directed. 72 Supply and fix in repairs 150 mm Aluminum anodised barrel tower bolts of extruded section 73 Supply and fix in repairs floor door stopper 150 mm size aluminium alloy body and tongue double legged, anodised fixed to door. 74 Supply and fix in repair 75 mm hasp and staple mild steel safety typeand fixed with screws all as specified and as directed. 75 Supply and fix in repair aluminium alloy wire cloth, 0.45 mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminum staples or beading complete. 76 Supply and fix aluminium alloy wire cloth, 0.45 mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminum staples or beading complete. 77 Hacking out old broken glass (any thickness, size, quality or description) form metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones complete all as specified and as directed. 78 Supply and fix sheet glass 4mm thick, ordinary quality and glazing withrubber beading/ oil putty area exc 0.5 sqm in each pane. 79 Material and labour 4mm thick sheet figured glass pin headed quality n exc 0.50 sqm in each pane and glazing with aluminium beading complete all as specified and as directed. 80 Supply and fix in repair aluminum (die cast) body door closer hydraulically regulated designation No. 2 universal type suitable for door shutters of 701 to 850mm in width and of weight between 36 to 60 Kg all as specified and as directed. 81 Supply and fix in repair looking mirror 600X450mm, selected quality glass mounted on 6mm thick PVC/AC building board/commercial plywood, PVC beading allround and fixed to wall complete all as specified and as directed. 82 Supply and fix in repair 20 mm bore curtain rods, anodised aluminium alloy, PVC coated with fixing brackets, stops, rollers etc all as specified and as directed. 83 Supply and fix in repair block board, grade 2 quality, interior grade, decorative type, both faces, 18/19mm thick as in cupboard, drawer repair & fixed with screws to timber frame work complete all as specified and as directed. 84 Supply and fix in repair both sides prelaminated medium density fibre board exterior grade 18/19 mm thick as in cupboard, drawer repair & fixed with screws to timber frame work complete all as specified and as directed. 85 Supply and fix in repair 0.9mm thick decorative laminate type 1 of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturers instructions complete all as specified and as directed. 86 Supply and fix stainless steel soft closing hydraullic hinges for shutter complete all as specified and as directed. 87 Supply and fix in repairs 125 mm stainless steel handles, cast type, polished for cupboard shutters etc. complete all as specified and as directed. 88 Supply and fixin repairs stainless steel telescopic drawer channel double ball bearing complete fixed all as per manufacturers instructions and all as directed by Engr -in charge. 89 Supply and fixin repairs Brass hat & coat hooks,solid body,175mm to 250mm. 90 Supply and fix in repairsBrass drawer handles,projection drop (50mmx65mm)on screwed plate. 91 Supply and fixin repairs Harrison rails anodised aluminium alloy with fixing brackets,stops,rollers etc 92 Supply and fixin repairs 4 Lever Brass Locks for drawer,grade-I,size75mm 93 Supply and fix in repair Mortice lock brass body, 100mm, 4 levers vertical type 94 Taking up or down steel tubing and connectors 25-32mm bore in new or old position (wall, ceiling, floor etc.) 95 Supply and fix in repair 32mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including removal of existing pipe complete all as specified and as directed. 96 Supply and fix in repair 32mm bore stop valves ccast copper alloy, fancy type screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipes (concealed type) all as specified and as directed. 97 Supply and fix in repair 20mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including removal of existing pipe complete all as specified and as directed. 98 Supply and fix20mm dia Brass Elbow for CPVC pipes for fixing of plumbing fittings 99 Supply and fix 20mm dia Brass Tee for CPVC pipes for fixing of plumbing fittings 100 Supply and fix 20mm dia male brass threaded adaptor (MTA/MBTA) for plumbing fittings 101 Supply and fix 20mm dia female brass threaded adaptor (FTA/FBTA) for plumbing fittings 102 Supply and fix20mm dia Union for CPVC pipes for fixing of plumbing fittings 103 Supply and fix 32 mm dia Union for CPVC pipes for fixing of plumbing fittings 104 Supply and fix32 mm dia Tank adaptor for CPVC pipes for fixing of plumbing fittings 105 Dimolition and breaking up drain pipes ( salt glazedware, AC,Reinfoced concreet, PVC pipe) of internal dia upto 200mmbore, set in cement mortar and taking out of trenches if required. 106 Supply and fix 110 mm dia, PVC rain water pipes, single socketed, in any length with sealant rubber ring joints including necessary MS flat Iron clamps of size (40 x 4mm) all as specified and as directed by the Engineer - in - Charge. 107 Supply and fix 75mm dia, PVC rain water pipes, single socketed, in any length with sealant rubber ring joints including necessary MS flat Iron clamps of size (40 x 4mm) all as specified and as directed by the Engineer - in - Charge. 108 Supply and fix PVC (SWR) bends 75mm dia. 109 Supply and fix PVC (SWR) bends 110mm dia. 110 Supply and fix PVC (SWR)S traps 110mm dia. 111 Supply and fix in repairs 75mmPVC (SWR) floor trap, plain with grating including joint with solvent cement 112 Supply and fix in repairs Matte finish stainless steel kitchen sink bowl type of any size complete all as specified and as directed. 113 Supply and fix in repair vitreous china, wash down water closet(EWC) white colour with PVC seat cover, closed pattern with flat bottom and cover with mild steel (CP) or aluminium hinging device fixed with necessary bolts complete all as specified. 114 Supply and fix in repair plastic water closet seat cover white colour closed pattern with flat bottom and cover and MSCP or aluminised hinging device. 115 Supply and fix in repair vitreous China wash basin, white coloured, flat back 550x400mm including waste coupling CP, fixing brackets, cutting for and pinning in ends of brackets all as specified and as directed. 116 Supply and fix in repair PVC valve less syphonic action type flushing cistern low level with inlet ball valve float and handle including brackets 10 ltrs capacity. 117 Supply and fix in repairs Vitreous China bowl full stall type Urinal (excluding flushing cistern, waste pipe) including water spredder,cupling etc. 118 Supply and fix 32mm dia low density polyethylene (LPDE) pipes of pressure rating 6kgf/sq.cm of minimum one meter lengrh suitable for waste pipe ofkitchen sink, urinal pote ,WHB etc. 119 Supply and fix in repair 15mm bore chromium plated bib taps (fancy type), long body cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed for iron pipes all as specified and as directed. 120 Supply and fix in repair 15mm dia bore pillar taps, cast copper alloy, fancy type capstan heads, chromium plated, screwed down high pressure, with long screwed shanks and fly-nuts, screwed for iron pipe all as specified and as directed. 121 Supply and fix in repair fancy type angular stop valve, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, chromium plated, fancy type, screwed both ends for iron pipe or for union and fixed, suitable for 15 mm bore pipe,complete all as specified and as directed. 122 Supply and fix in repair chromium plated health faucets (hand held shower type) with shut off valve (thumb or push button type) to allow controlled and continuous flow of water with adequate length and wall mounted pedestal for hanging the faucet etc complete including necessary 900 mm connection pipes. 123 Supply and fix in repair single lever tall body wash basin mixer tapcomplete all as specified and as directed.Make: Jaquar Cat No:KUP 35005BPM or equivalent in Hindware/Kohler. 124 Supply and fix in repair wall mixer complete all as specified and as directed.Make: Jaquar Cat No:FLR CHR 5281N or equivalent in Hindware/Kohler. 125 Supply and fix in repair aquamax concealed body of single lever shower mixer with 3 way divertor all as specified and as directed.Make: Jaquar Cat No : ALD-783 or equivalent in Hindware/Kohler. 126 Supply and fix in repair Bib cock all as specified and as directed.Make: Jaquar Cat No : KUP CHR 35037PM or equivalent in Hindware/Kohler. 127 Supply and fix in repair Hand shower all as specified and as directed.Make: Jaquar Cat No : HSH CHR 1655 or equivalent in Hindware/Kohler. 128 Supply and fix in repair shower arm 60cmall as specified and as directed.Make: Jaquar Cat No :SHA CHR 455L600 or equivalent in Hindware/Kohler. 129 Supply and fix in repair SS overhead shower square 240x240mm all as specified and as directed.Make: Jaquar Cat No :OHS CHR 1629 or equivalent in Hindware/Kohler. 130 Supply and fix in repairPVC connections 15mm dia& 450mm length with PTMT nuts for urinals WHB, flush tanks etc all as specified and as directed. 131 Supply and fix in repair cast copper alloy, brass chromium plated towel rail, 600mm long complete. 132 Supply and fix in repair 125mm size brass chromium plated shower rose complete. 133 Supply and fix in repair waste coupling, brass, chromium platedwith long shank, half thread, 32mm dia, for WHB/urinal etc. complete. 134 Supply and fix in repair rotational moulded PVC water storage tanks 250 ltr capacity (any shape with closed top) hoisted and fixed in any position all as specified including taking down old broken/cracked water tank and connecting the water pipe line in position. 135 Supply and fix in repair rotational moulded PVC water storage tanks 750 ltr capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified including taking down old broken/cracked water tank and connecting the water pipe line in position. 136 Cleaning of water tank exc 250 & n.exc500 lit, including cleaning all scales and dirts from inside of tank using bleaching powder and washed with water,complete all as specified including taking down and re-fixing of float valve. Including mentioning date of cleaning on water tank using white synthetic enamel paint as existing complete all as specified and as directed. Note :- After Cleaning of water tank,The rep of contractor should check during water supply time and ensure water is reaching to the qtr and float valve is working properly and no leakages are there at joints. 137 All as per item No 135.00 here-in-before but exc 500 & n. exc1000 lit, complete all as specified and as directed. 138 Supply and fix in repairBall brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed for 40 mm dia pipes
BRR : 8471468
Tender For Repair Work Of Non Residential Buildings - Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes inCement mortar 1:6 (1 cement : 4 coarse sand) DSR no 6.4.2 2 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1 :2:4 (1 cement : 2 coarse sand (zone-Ill) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)DSR 4.1.3 3 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete uptoor above plinth level. DSR 5.22.1 4 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.DSR 15.56 5 12 mm cement plaster of mix :DSR 13.1.2 1:6 (1 cement: 6 fine sand) DSR 6 Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc.complete DSR No 13.88 7 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surfac eto prepare the surface even and smooth complete. DSR 13.80 8 Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. DSR 13.85.3 9 Distempering with 1st quality acrylic distemper (ready mixed) having VOC(Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour DSR 13.81.1 (two coats) 10 Finishing walls with water proofing cement paint of required shade : DSR 13.109.2 11 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade DSR 13.112.1 12 Cement concrete flooring 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement sluny, but excluding the cost of nosing of steps etc. complete. DSR 11.3.1 40 mm thick with 20 mm nominal size stone aggregate 13 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1 :4 (1 Cement: 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. DSR 11.37 14 Providing and laying vitrified floor tiles in different sizes (thickness to bespecified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1 :4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. DSR 11.41.2 15 Kata stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement: 4 coarse sand): DSR 11.26.1 25 mm thick 16 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. DSR 10.25.1 17 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. D.S.R.9.135.1 18 Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: D.S.R 14.5.1 19 Renewing glass panes, with wooden fillets wherever necessary:D.S.R 14.6.1 20 Supplying and fixing new wooden fillets wherever necessary: D.S.R 14.8.1 21 Renewal of old putty of glass panes (length) metre D.S.R 14.9 22 Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as perthe direction of the Engineer-in-charge.DSR 14.85 23 Providing and fixing ISi marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. DSR 9.21.1 35 mm thick including ISi marked Stainless Steel butt hingeswith necessary screws 24 Applying priming coat: With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood DSR 13.50.2 25 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : DSR 13.99 26 Providing and fixing ISi marked oxidised M.S. sliding door bolts with nuts and screws etc. complete (Copper oxidised as per IS 1378) DSR 9.62.1 27 Providing and fixing ISi marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) DSR 9.63 28 Providing and fixing ISi marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete (Copper oxidised as per IS 1378) DSR 9.66.1 29 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,DSR 12.41 (110 mm pvc pipe 30 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.DSR 18.7 (15 mm pvc pipe) 31 Providing and fixing brass bib cock of approved quality.DSR 18.15 32 Providing and fixing brass stop cock of approved quality .D.S.R.18.16 33 Providing and fixing uplasticised PVC connection pipe with brass unions : .D.S.R.18.21.1 34 Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings : DSR 17.25.2 35 Providing and fixing P.V.C. waste pipe for sink or wash basin includingP.V.C. waste fittings complete. DSR 17.28.1 36 Dismantling W.C. Pan of all sizes including disposal of dismantled materials including malba all complete as per directions of Engineer-in-Charge. DSR 14.82 37 Providing and fixing white vitreous china water closet squatting pan (Indian type) :17.13.2 Orissa pattern W.C. pan of size 580x440 mm DSR17.13 38 Providing and fixing white vitreous china pedestal type (European type/wash down type) water closet pan. DSR 17.15 39 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. DSR 17.16A 40 Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittingsand fixtures complete. DSR 17.18 41 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizesrespectively. DSR 17.23 42 Providing and fixing white vitreous china squatting plate urinal with integral rim longitudinal flush pipe. DSR 17.24each 4048.65 43 Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. pan. DSR 17.22 44 Disconnecting damaged overhead/terrace PVC water storage tank of any size from water supply line and removing from the terrace includingshifting at ground level as per direction of Engineer-in-charge. DSR 14.79 45 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.D.S.R.18.48 46 Dry brick on edge flooring in required pattern with bricks of class designation 7 .5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks.DSR 11.2 47 Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.DSR 16.83 48 Laying old cement cocrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. (Old CC paver blocks shall be supplied by the department free of cost). DSR 16.84 49 Providing and laying of factory made 80 mm thick rubber moulded Interlocking cement concrete tiles (30mpa) including 25mm thick compacted bed of fine sand compacting and proper embedding/ laying of Interlocking tiles leveling and dressing of surface to required level and slope, filling joints with fine sand including the cost of material, labour T&P etc.required for proper completion of work as directed by Engineer-in-Charge.
Disclaimer
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tender Detail
| Website | https://prasarbharati.eproc.in/ProductPB/publicDash |
| Quantity | 0 |
| MSME Exemption | No |
| Tender Type | Open Tender |
| Startup Exemption | Click Here |
| Competitive Bidding | NCB |
TENDER INSIGHTS
858
Electric TendersLive
Tell us about your Product / Services,
We will Find Tenders for you