TDR : 56880498
Central Public Works Department

Tender Brief :

Gorakhpur, Uttar Pradesh

Supply Installation Testing And Commissioning Of Automatic Rescue Device And Internal Resistance Components In 2 Nos Johnson Make Lifts In Part 3 G Plus 6 Of Academic Building At IISER Berhampur Odisha

Published: 06 Aug 2026
Opening: 14 Aug 2026
Closing: 14 Aug 2026
Amount: 1.54 Lakhs
EMD: Ref. Documents
Tender Fee: Ref. Documents


Works Abrasive and Abrasive media Abrasive Wheels Absorbents Acidizing Equipments Agricultural Watering Equipment
3
Days Left
Tender Summary / Eligibility Criteria
Supply Installation Testing And Commissioning Of Automatic Rescue Device And Internal Resistance Components In 2 Nos Johnson Make Lifts In Part 3 G Plus 6 Of Academic Building At IISER Berhampur Odisha
Documents Download All
72140619-f1bb-4f0e-a776-f040139cdf0e
72140619-f1bb-4f0e-a776-f040139cdf0e.html
DocumentsList
DocumentsList.zip
No Boq
No Corrigendum
Probable Bidders

AI engine predicts probable bidders to help you bid strategically.

MSME Exception
Explore More →
Technical
Tender involves procurement of high capacity electrical equipment including diaphragm coupling of pump & motor with 90kW capacity at 2900 RPM. The project scope includes installation, testing, commissioning and operational handover.
Previous / Similar Result
BRR : 9749428 Tender For Comprehensive Maintenance Amc Of Lift In Various Lab At M House Area Under Ge I Rnd Delhi; 1 comprehensive maintenance (Routine, preventive, periodical and breakdown) of Passenger/goods/service Lifts installed in following bldgs at METCALFE HOUSE Complex JCBareaas mentioned here-in-after, in reliable, safe and efficient manner using latest techniques & expertise through OEM by regularly examining, lubricating and adjusting the mechanical and electrical driving equipments/componentents, governor sleeve, shaft assembly, bearing/contact, governor jaws, car & hall mechanical push buttons, car & hall position indicators, car direction indicators, car and landing door drive/sensor and all other car and landing signal/ fixtures, deflectors, car and counter weight guide rails and bufferstravelling cable etc with and including replacement of defective / spares parts mentioned in BOQ/Sch - A as supply only and replacement of all kind of defective / spares parts other than mentioned in BOQ/Sch - A i.e. car/landing door sill, lift coil, lever bell crank, fuse holder, transformer, rack harness, guide shoe, light shield, any type of diode panel, push button assembly guide operator, kit door, bush bearing, copper contacts, line brakes, sight guard, any type of glass for hall button, emergency light, fireman control switch/ glass, announcement system, all type of safety, mounting sundrise, wire, lugs, nut, bolts, screws, lubricant, gear oil, aircord, landing wheel, aircord wheel, all types of control cards/logic cards, rewinding of motors(Main & Doors) etc and all machine works i.e. welding, cutting, drilling etc or any other parts/components which is not includ above as and when required to keeping the lifts in serviceable conditions round the clock (on all days including holidays) and during all weather/climate conditions to the entire satisfaction of Engineer-in-charge, complete all as directed for following Lifts. 2 Goods cumpassnger slift of capacity1500 KG with traveling speed of upto 1.0 mtrs/sec,(Ground +6 floors) installedOLD SAG LAB atM House including all instruments and controls complete all as specified and directed. (Make of Lift- Skylark). 3 Passenger lift of capacity 06 Passenger(408 Kgs) with traveling speed of upto 1.0 mtrs/sec, (Ground +5 floors) installed atOLD SAG LAB atMHouseincluding all instruments and controls complete all as specified and directed.(Make of Lift- Thyssen Krupp). 4 Passnager lift of capacity20 passangers forwith traveling speed of upto 1.0 mtrs/sec, six floors (Ground + 5 floors) installed at SAG Lab at MHouse including all instruments and controls complete all as specified and directed.(Make of Lift- JOHNSON). 5 passnger lift of capacity08 passangers (544 KG) with traveling speed of upto 1.0 mtrs/sec, (Ground + 5 floors) installed at DESIDOC `A Block Building MHouse including all instruments and controls complete all as specified and directed.(Make of Lift- Thyssen Krupp). 6 Passengerlift of capacity08 passangers (408 KG) with traveling speed of upto 1.0 mtrs/sec,(Ground + 5 floors) installed at DESIDOC `A Block Building MHouse including all instruments and controls complete all as specified and directed.(Make of Lift- Thyssen Krupp). 7 Passanger lift of capacity05 passangers (408 Kgs) with traveling speed of upto 1.0 mtrs/sec,(Ground + 5 floors) installed at DESIDOC `B Block Building ofMHouseincluding all instruments and controls complete all as specified and directed. (Make of Lift- Thyssen Krupp). 8 Passengerlift of capacity08 passangers with traveling speed of upto 1.0 mtrs/sec,(Ground + 4 floors) installed at CEPTAM LAB at MHouse including all instruments and controls complete all as specified and directed.(Make of Lift- Schindler). 9 Passengerlift of capacity 08 passangerswith traveling speed of upto 1.0 mtrs/sec, (Ground + 4 floors) installed at CEPTAM LAB at MHouse including all instruments and controls complete all as specified and directed. (Make of Lift- Schindler). 10 Passenger lift of capacity08 passangers(544Kgs) with traveling speed of upto 1.0 mtrs/sec, (Ground + 5 floors) installed at ISSA LAB at MHouse including all instruments and controls complete all as specified and directed. (Make of Lift- OTIS). 11 Passengerlift of capacity08 passangers(544Kgs) with traveling speed of upto 1.0 mtrs/sec, (Ground + 5 floors) installed at ISSA LAB at MHouse including all instruments and controls complete all as specified and directed. (Make of Lift- OTIS). 12 Passengerlift of capacity 13 Passengers (844 KG) with traveling speed of upto 1.0 mtrs/sec, (G +6 Floor) installed atBhaskar Building MHouseincluding all instruments and controls complete all as specified and directed.(Make of Lift- OTIS). 13 Passengerlift of capacity 13 Passengers (844 KG) with traveling speed of upto 1.0 mtrs/sec, (G +6 Floor) installed atBhaskar Building MHouseincluding all instruments and controls complete all as specified and directed. (Make of Lift- OTIS). 14 Service lift of capacity200 KG for two floors (Ground + 1 Upper floor) with traveling speed of upto .5 mtrs/sec,through OEMinstalled at LASTEC wet canteen atMHouse including all instruments and controls complete all as specified and directed. (Make of Lift- JOHNSON) . 15 Passenger lift of capacity 10 Passenger with traveling speed of upto 1.0 mtrs/sec, G +4 Floor (Basement + Ground +3 floors) installed atJCB BLDG No-01 in MHouse including all instruments and controls complete all as specified and directed. (Make of Lift- OTIS). 16 Passengerlift of capacity10 Passenger G +4 FloorLiftwith traveling speed of upto 1.0 mtrs/sec, (Basement + Ground +3 floors) installed atJCB BLDG No-02 in MHouse including all instruments and controls complete all as specified and directed. .(Make of Lift- OTIS). 17 Goods cumpassengerLiftof capacity 1000 Kgswith traveling speed of upto 1.0 mtrs/sec, G +4 Floor (Basement + Ground +3 floors) installed atJCB BLDG No-01 in MHouse including all instruments and controls complete all as specified and directed. (Make of Lift- UTL). 18 Takingout existing unserviceable hoist steel wire rope after disconnecting from counter weight pulley and car cabin and supply & fix new steel wire rope 13 mm dia, ungalvanised 8/19 construction, conforming to IS-14665 including making necessary connection with weigh, pully and car cabin GI clamps, nuts, bolts, washers etc,complete all as specified and directed. 19 Taking out existing unserviceable hoist steel wire rope after disconnecting from counter weight pulley and car cabin and supply & fix new steel wire rope 10 mm dia, ungalvanised 8/19 construction, conforming to IS-14665 including making necessary connection with weigh, pully and car cabin GI clamps, nuts, bolts, washers etc complete all as specified and directed. 20 Taking down carefully existing old false ceiling with fan grill & LED up to 08 passenger lift from existing and supply & fixing new false ceiling made of 1.2mm thick stainless steel with hair line finish (N-304) fitted with aluminium square fan withgrill & 10/12 watt LED at 4 Nos, complete all as specified and directed. 21 Taking down carefully existing old false ceiling with fan grill & LED 13 passanger and supply & fixing new false ceiling made of 1.2mm thick stainless steel with hair line finish (N-304) fitted with aluminium square fan withgrill & 10/12 watt LED at 4 Nos, complete all as specified and directed. 22 Takingout existing old unserviceable control panelupto 08/13 passenger existing lift after disconnected all electrical and control wiring connection carefully and supply, installation, testing and commissioning new control panal withmicroprocessor based AC variable voltage variable frequency (ACVVVF) drive close loop. The lift controller shall be wall/floor mounted, vertical, totally enclosed cubicle type with hinged doors on the front and/or the rear to provide easy access to all components in the controller. The cubicle shall be well ventilated such that the temperature inside never exceeds the safe limits of the components at ambient room conditions in the machine room. The controller shall operate within the supply voltage variation of plus 10% to minus 10% of the nominal voltage. An inbuilt voltage stabilizer shall be provided in the controller for the purpose. The controller shall be complete with relay protection against the following:  Over current  Under voltage  Single phasing  Phase reversal  Earth leakage  Over voltage – 3Phase  Spikes & Surges Control panels & drive systems shall be designed to meet the requirements laid down by the EN12015 standards relevant to Electro-Magnetic Compatibility (EMC). Lift motor control system shall be electronic closed-loop control to ensure fail safe motor over speed controls and stopping accuracy of ± 3 mm to ± 5 mm. Load compensation circuits shall also be included to further improve upon the levelling accuracy. The levelling shall be ensured within ± 3 mm to ± 5 mm. An Automatic Phase reversal device shall be provided on the controller which shall be designed to protect the lift equipment against phase reversal and phase failure. The controller shall be designed to cut off the power supply, apply the brake and bring the car to a rest in the event of any of the above failures occurring. System should automatically restart when power is restored. System memory should be retained in the event of power failure or disturbance. Lifts should not go in to correction mode or correction run to the lowest floor / highest floor to update its position & memory. The controlled panel should be compatiable as per existing controlled system and should be recommended as per OEM of existng Lift complete all as specified and as directed. Note: Cotractor Shall be submitted techanical data sheet of Control panel before prorcurement for approval. 23 Takingout existing defective unserviceable main drive (any type) from existing control panel and supply & fixing new variable voltage, variable frequency drive (VVVF)upto 15 KW suitable for EXISTING LIFTand including making necessary electric connection, complete all as specified and directed. 24 Taking out old unserviceable Automatic rescue device (ARD)up to8/10/13 passenger lift with sealed maintenance free (SFM) batteries of 12 volts, up to 18 AH ( 06nos battery) after disconnected all electrical and control wiring connection carefully and supply, installation, testing and commissioning new Automatic rescue device (ARD) . The ARD shall be wall/floor mounted, vertical, totally enclosed cubicle type with hinged doors on the front and/or the rear to provide easy access to all components in the ARD. The cubicle shall be well ventilated such that the temperature inside never exceeds the safe limits of the components at ambient room conditions in the machine room. The ARD shall operate within the supply voltage variation of plus 10% to minus 10% of the nominal voltage. An inbuilt voltage stabilizer shall be provided in the ARD for the purpose. The ARD shall be complete with relay protection against the following:  Over current  Under voltage  Single phasing  Phase reversal  Earth leakage  Over voltage – 3Phase  Spikes & Surges. The ARD should be automatic evacuation to the nearest floor during power failure or other emergencies. All necessary wiring cable and Connectors connections for proper integration with the lifts control system. The ARD should be working correctly and integrating it with the lifts overall existing control system and should be recommended as per OEM of existng Lift complete all as specified and as directed. Note: Cotractor Shall be submitted techanical data sheet of Control panel before purcurment for approval. 25 Taking out existing old defective door sensor and supply & fixing new sensor with 3D INFRA RED safety edge with power unit on car door to safeguard passenger entering and leaving the liftsuitable for 08/10/13/20 passenger capacity lift complete all as specified and directed. 26 Taking out existing unserviceableground floorLOP up to 20 passenger cum goodslift assembly after disconnected all electrical and control wiring connection carefully and supply & fixing new car operating assembly with and including illuminated push button for floor position, alarm, nonstop, door stop, door close, cabin fan, cabin light stop, attendant out key etc, direction indicator of 7 segment display with SPI card on stainless steel face plate duly controlled and electric connection, also including necessary wiring for laminated push button of each floor, cutting wall, making good the surfaces to match with the existing surfaces, suitable forGoods/Passenger lift. complete all as specified and directed. 27 Taking out existing unserviceableTop floorLOP20 passenger cum goodsliftassembly after disconnected all electrical and control wiring connection carefully and supply & fixing new car operating assembly with and including illuminated push button for floor position, alarm, nonstop, door stop, door close, cabin fan, cabin light stop, attendant out key etc, direction indicator of 7 segment display with SPI card on stainless steel face plate duly controlled and electric connection, also including necessary wiring for laminated push button of each floor, cutting wall, making good the surfaces to match with the existing surfaces, suitable forGoods/Passenger lift. complete all as specified and directed. 28 Taking out existing unserviceable LOP 1st foor tofifth floor up to 20 passenger cum goodslift assembly after disconnected all electrical and control wiring connection carefully and supply & fixing new car assembly with and including illuminated push button for floor position, alarm, nonstop, door stop, door close, cabin fan, cabin light stop, attendant out key etc, direction indicator of 7 segment display with SPI card on stainless steel face plate duly controlled and electric connection, also including necessary wiring for laminated push button of each floor, cutting wall, making good the surfaces to match with the existing surfaces, suitable forGoods/Passenger lift. complete all as specified and directed. 29 Taking out existing unserviceable COP8/10/13 passenger cum goods (G+)lift assembly after disconnected all electrical and control wiring connection carefully and supply & fixing new car operating panel (COP) assembly with and including illuminated push button for floor position, alarm, nonstop, door stop, door close, cabin fan, cabin light stop, attendant out key etc, direction indicator of 7 segment display with SPI card on stainless steel face plate duly controlled and electric connection, also including necessary wiring for laminated push button of each floor, cutting wall, making good the surfaces to match with the existing surfaces, suitable forGoods/Passenger lift. complete all as specified and directed. 30 Taking out existing unserviceable cabin fan and supply & fixing new cabin fan, non-oscilating type, axial flow, single speed, 250mm to 300mm sweep, 240 volt, with grill, complete all as specified and directed. 31 Taking out existing light fittings fromliftcabinand in lieu S & F New LED light fittings,complete with and including LED 10/12 watt, all accessories, fixutres complete all as specified and directed. 32 Taking out existing light fittings fromlift Shaft and in lieu S & F New LED light fittings, complete with and including LED 10/12 watt, all accessories, fixutres complete all as specified and directed. 33 Taking out existing old/ defective PVCflooring matand S & F NewantistaticPVC flooring 3mm thick flame resistance UV coating with superior qualityandthickness of mat 3 mm dully solution/adhesiveafter scraping ,cleaning surface preparing of old surface andcolour/design of mat shal be approved by Engr-in -chargea complete all as specified and directed . 34 Taking down existing unserviceble batteries from machine room and supply & fixing new sealed maintenance free (SFM) batteries of 12 volts, 07AH and making necessary connections with and including copper lead to connect brass terminals of batteries, complete all as specified and directed. 35 Taking down existing unserviceble batteries from machine room and supply & fixing new sealed maintenance free (SFM) batteries of 12 volts, 12 AH and making necessary connections with and including copper lead to connect brass terminals of batteries, complete all as specified and directed. 36 Taking down existing unserviceble batteries from machine room and supply & fixing new sealed maintenance free (SFM) batteries of 12 volts, 18 AH and making necessary connections with and including copper lead to connect brass terminals of batteries, complete all as specified and directed. 37 Note : (For Serial No 01 to 20) The entire work mentioned in this BOQ/Sch - A. Item No. 1 to 17 including comprehensive, preventive and periodical maintenance of lifts / elevators shall be got executed through OEM or any reputed lifts manufacturer i.e. M/s Thyssen Krupp Elevator (India) / M/s OTIS Elevator India Pvt Ltd/ M/s Schindler (India) /M/s OTIS/M/s Johnson/M/s UTL, M/s Skylark only. The contractor shall upload / submit the scanned copy of MOU for AMC (inclusive of material) with lifts manufacturer, as mentioned above, item No. 1 under BOQ item ser for BOQitem No 1.01 to 1.16alongwith his application. The contractor shall also have to submit hard copy of MoU with his application.The lifts will be handed over to contractor in as and when condition and no claim in this effect will be accepted at any stage.The cost of all kind of replaced defective parts/spare /control cards/oil/ lubricants etc, other than mentioned in BOQ/Sch A, as and when required to making the lift/elevator fully functional, is deemed to be included in quoted rates and no extra cost shall be paid to the contractor in this effect. Hence, the bidder is advised to visit the site to assess the quantum of work to be carried out in this contract and quote thier rates accordingly. 38 The comnrehensive /preventive (periodical maintenance includes weekly fortnightly, monthly, quarterly, half yearly inspection/testing as per service manual or as per IS standard. The inspection / test report will be submitted to Engineer-in-charge.The complete records of replaced spare parts, other than mentioned in BOQ/SchA, will be maintained and will be produced to Engineer-in-charge on monthlybasis or as and when asked to produce the same.The complete records of replaced spare parts, other than mentioned in BOQ/SchA, will be maintained and will be produced to Engineer-in-charge on monthlybasis or as and when asked to produce the same.All the complaint(s) will be addressed within 02 hrs from the time of receipt ofcomplaint. If, contractor or his tradesmen fails to attend the complaint within 02 hrs from the time of receipt of complaint, the compensation/penalty of Rs. 500.00 (Rupees Five Hundred only) per complaint per hr for first 04 hrs and after that Rs 1000 00(Rupees One Thousand Only) per complaint per hr shall be recovered from the contractors dues. The cost of transportation (to and fro) and other necessary equipment shall be arranged / brought by contractor to complete the job and no extra cost shall be paid to the contractor in this effect.All the complaints are required to be rectified within 24 hrs or within stipulated time given by the JE/Engineer-in-Charge, if, contractor of his tradesmen fails to rectify the defects, the compensation of Rs. 1000.00 (Rupees one thousand only) per complaint for each date (i.e. 24 hours) shall be recovered from the contractors dues. The decision of accepting officer is this regard shall be final and binding.
Contract Date : 09 Mar, 2026   |   Contract Value : 35.71 Lakhs
BRR : 9463811 Construction work of record room on 4th, 5th and 6th floor of old building in authority office - Site Clearance and Dismantling Works 2 Carefull shifting of records and racks to safe place as per the directions of engineer-in-charge. 3 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area 3 sq. metres and belowDSR 15.12.1 4 Dismantling steel work manually/ by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per direction of Engineer-in-charge.DSR 15.19 5 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mmDSR 15.23.1 6 Dismantling wooden boardings in lining of walls and partitions, excluding supporting members but including stacking within 50 metres lead : Thickness above 25 mm up to 40 mmDSR 15.39.3 7 Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. completeDSR 13.88 8 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortarDSR 15.7.4 9 Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-incharge.DSR 15.57 10 Labour charge for dismantling of sanitary installations like wash basin, urinal, etc. (3 No for 2 days) 11 Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China)including stacking of useful materials near the site and disposal ofunserviceable materials within 50 metres lead.DSR 15.52 12 Removal of old wiring 13 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.DSR 15.60 14 Interior Works 15 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand)DSR 6.13.2 16 Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineerin- Charge. With cement mortar 1:4 (1 cement : 4 fine sand)DSR 14.1.1 17 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.DSR 13.80 18 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primerDSR 13.41.1 19 Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi chambered frame, sash and mullion/coupler (where ever required)extruded profiles having minimum wall thickness of .70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367: Part 1 To 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash 7 mullion (if required) shall be mitred cut and fusion welded/ mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rof of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-charge. 20 Wire mesh/ Glazing of plain/ toughened/ laminated/ double glass unit with/ without high performance coatings as per design requirements and conforming to IS: 3548 & IS16231 shall be paid separately.Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for: (i) Sites with basic wind speed>45 m/sec as per IS 875-Part 3 (ii) Sites with structure height more than 20m for all wind speeds9.147.A4. Three track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body.Using R3 series with frame (98 mm & above) x (40 mm & above) & both glazed and fly screen sash (30 mm & above) x (55 mm & above) with zinc alloy (zamak) powder coated handle on every glazed panel along with multi-point locking system. (Heigh above 1.8 m)DSR 9.147.A4.2 21 Toughened glass 12 mm thicknessDSR 8778 22 Stainless steel wire guage (Grade-304) aperture 1.4 mm and0.50mm dia wireDSR 8737 23 Weather Silicon sealantDSR 8646 24 Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity < 0.043 W/m K as per ASTM 518:1991, in true horizontal level suspended on interlocking metal powder coated T-Grid of hot dipped galvanised iron section of 0.40 mm thick on Silhouette profile,rotary stiched double webbed white with 6mm reveal profile (white/black),comprising of main-T runners of size 15x42mm of length 3000 mm, cross - T of size 15x42 mm of length 1200 mm and secondary intermediate cross-T of size 15x42 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 22x19x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge.With 15 mm thick integral densified micro edge light weight calcium silicate false ceiling tilesDSR 26.23.1 25 Mirror polishing on marble work/Granite work/stone work where ever required to give high gloss finish complete.DSR 8.6 26 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thickDSR 11.26.1 27 Providing and fixing internal wall panels on Light gauge steel frame work with 12.5 mm thick gypsum plaster board conforming IS 2095:2011 fixed on cement board as per standard sizes fixed with self-drilling / taping screws / fasteners @ 60 cm c/c of approved make, Screws shall be of counter sunk rib head of 1.60 mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm. Proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish.(cost of frame work to be paid for separately). Cement Bonded particle board 8 mm (Termite, Fire & Moisture Resistance), as per IS:14276 : 1995 28 Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.DSR 9.121 29 30 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF)/Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS: 14856, complete as per direction of Engineer-incharge.DSR 9.122.2 30 Providing and fixing 18mm thick both sides Pre-laminated cement bonded wood particle board as per IS : 15786:2008 of approved brand and shade with suitable full threaded steel screws etc. in partitions, boxes, shelves, racks and cupboard, kitchen cabinet under kitchen counter etc. all complete as per direction of Engineer-in-charge (Note: Fittings to be paid separately). 18 mm thickDSR 9.166.1 31 Providing and fixing 6mm thick both sides Pre-laminated cement bonded wood particle board as per IS : 15786:2008 of approved brand and shade with suitable full threaded steel screws etc. on the backing of racks, drawer, cupboard, kitchen cabinet under kitchen counter etc. all complete as per direction of Engineer-incharge.DSR 9.167 32 Providing and fixing cupboard shutter with 19mm thick one side decorative and other side balancing lamination factory pressed BWP grade marine ply as per IS 710 of approved brand including 2mm thick PVC edge banding tape with hot glue by edge bending machine etc. with auto closing spring loaded hinges (hydraulic type) etc. complete as per direction of Engineer-in-charge.(Payment of providing and fixing auto closing hinges shall be paid separately)DSR 9.168 33 Providing and fixing stainless steel fancy handle of approved make fixed with SS screws etc. complete as per direction of Engineer-in-charge. 200mmDSR 9.170.1 34 Providing and fixing concealed hinge of approved quality for 19-20mm thick door with stainless steel screws complete :DSR 26.11 35 Washroom Upgradation 36 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).DSR 5.3 37 Providing and laying PCC 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)DSR 4.1.8 38 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mmDSR 11.41.2 39 Tile work in skirting, risers of steps and dado up to 2 m height over 12 mm thick bed of cement mortar 1:3 (1 cement :3 coarse sand) and jointed with grey cement slurry @ 3.3 kg/sqm, including pointing in white cement mixed with pigment of matching shade complete.DSr 11.22 40 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.DSR 17.31 41 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lidDSR 17.2.1 42 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever requiredOne urinal basin with 5 litre white PVC automatic flushing cisternDSR 17.4.1 43 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tapDSR 17.7.2 44 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - chargeDSR 17.16A 45 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.DSR 17.28 46 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high glossfinish etc. complete at all levels.Granite stone slab of all colour and texture except black, Cherry/Ruby redArea of slab over 0.50 sqmDSR 8.2.3.2 47 Mobile Storage Compactors 48 Make: GodrejMain Body:(a) Construction:Rigid Knock Down construction made of 0.8 thk. CRCA Steel conforming to IS: 513 Gr.D. Each body block consists of 1 Main unit & then Add-on units (0, 1,2,3 depending on no. of bays 1, 2, 3, 4 respectively). Each unit has 5 loading levels formed by 4 nos. adjustable shelves for 1980 Height body and 6 loading levels with 5 nos. adjustable shelves for 2361 Height body.Body units are mounted on an understructure which is fixed or moving.The body comprises the following components: 49 1. Front Cover: It is the foremost panel of the body on which the handles (Push pull)/ Drive unit (Drive Type) are fixed. It is made of 0.8 thk. CRCA Steel conforming to IS: 513 Gr.D. The front cover has a pattern of holes on the front surface for ventilation purpose.2. Back Cover: It is the backmost panel of the body and is the mirror image of the front cover. It is made of 0.8 thk. CRCA Steel conforming to IS: 513 Gr.D. The back cover has a pattern of holes on the surface for ventilation purpose.3. Back Panel: The back panels are made of 0.6 thk. CRCA Steel conforming to IS: 513 Gr.D. There are two back panels – Top back panel and Bottom back panel for 1980H unit as well as 2361H unit. The two back panels are fixed together using machine screws. The purpose of the back panel is to act as a divider between 2 opposite shelves in twin body (TM/TD). When the entire optimizer layout is locked it also prevents access to inside files from the outside in case of single body (SS/SD/SL/LD).4. Shared Panel: The shared panel acts as a partition between two adjacent bodies. It is made of 0.8 thk. CRCA Steel conforming to IS: 513 Gr.D.5. Door Frame: The door frame assembly is made of 2 vertical door stiffeners, a top horizontal stiffener and a bottom horizontal stiffener. It provides rigidity to the entire body as the topmost shelf is pop riveted with the back panel as well as both the vertical door frame. The door frame is also useful if the customer chooses to have doors for the optimizer as the doors are hinged about the door frame. It is made of 0.8 thk. CRCA Steel conforming to IS: 513 Gr.D.6. Tie rod assembly: The tie rod assembly acts as a substitute to the back panels (only in twin body) if the customer chooses to not have back panels. The assembly consists of 2 tie rods, 4 fixing brackets and 2 turnbuckles. The tie rods are fixed in a shape of ‘X’ between two opposite shelves. The tie rods are made of 4mm diameter rods of MS while the fixing brackets are made of 2mm thk. CRCA Steel conforming to IS: 513 Gr.D. This assembly is available for both heights – 1980H and 2361H 50 Height for Push Pull Optimizer:Optimizer Height from ground is 2080 mm (1980 body + 65 undercarriage + 61.5 channel system).Height for Drive Type Optimizer:Optimizer Height for ground for 1980H body is 2121.5mm (1980 body + 80 understructure + 61.5 channel system).Optimizer Height for ground for 2361H body is 2502.5mm (2361 body + 80 understructure + 61.5 channel system). 51 Finish:The bodies including shelves are given antirust surface treatment & are coated with epoxy polyester powder. It involves an 8-step treatment consisting of Hot water rinse, Knock of degreasing, degreasing, cold water rinse, phosphating, cold water rinse, and passivation & dry off oven treatment. Final finish consists of epoxy polyester powder coating of approved color & shade with a Dry Film Thickness of minimum 40 microns. The testing of paint is done for various physical & chemical properties as per IS: 101. The material is then oven baked with a controlled temperature of 180 deg.C to 200 deg.C. 52 Shelf:(a) Construction:It is made of 0.7 thk CRCA steel conforming to IS: 513 Gr.D or DD. Its max load bearing capacity is 100 Kg uniformly distributed per shelf. For P1 and P2 type of Configuration recommended shelf load is less than 100kg (Refer UDL chart below). This is done to ensure that the unit is light enough for one person to pull/push with a handle even at recommended full load capacity. Shelf can be placed at clear height of 386mm from bottom in everybody. The last loading level for shelf is 1721mm from ground level for 1980H body and 2107mm from ground for 2361H body.Shelves are mounted on support brackets & shelf level can be adjusted at approx. 25.4 pitches. There are 4 adjustable shelves per body for 1980H and 5 adjustable shelves per body for 2361H, giving 5 and 6 loading levels for 1980H and 2361H body respectively.(b) Storage capacity per shelf:The shelf is 1180mm in length and can hold up to 13 nos. of box files of size 85mm x 345mm x 285mm. 53 Understructure:(a) Construction:Push Pull Understructure:-The Understructure is a welded frame suitably fabricated to bear the loads based on configuration. The frame consists of the following parts: Main channel, body-fixing channel, body-fixing angle and bearing-fixing angle. All the components are made of CRCA sheet 2 mm thk conforming to IS:513.Drive Type Understructure:-The Understructure is a welded frame suitably fabricated to bear the loads based on configuration. The frame consists of the following parts: Main channel, body-fixing channel, U-channel and Z-channel. All the components are made of HR sheet 3 mm thk. conforming to IS:2062.(b) Size:Sizes of Understructure:Push Pull OptimizerSingle Static / Single Last – 1200 x (no. of bays)X 396 (Depth) X 65 (Height)Twin Mobile - 1200 x (no. of bays)X 796 (Depth) X 65 (Height)Drive Type OptimizerStatic Drive / Last Drive – 1200 x (no. of bays)X 396 (Depth) X 80 (Height)Twin Drive - 1200 x (no. of bays) X 796 (Depth) X 80 (Height)Refer Table 3 for dimensions as per number of bays.External Load carrying capacity per understructure -PUSH-PULL/ MANUAL TYPE (Configuration – TYPE P1) - 600 Kg. MaximumPUSH-PULL/ MANUAL TYPE (Configuration – TYPE P2) - 600 Kg. MaximumDRIVE TYPE (Configuration - TYPE D2) - 2400 Kg. Maximum.DRIVE TYPE (Configuration – Type D3) – 3600 Kg Maximum.DRIVE TYPE (Configuration – Type D4) - 4800 Kg Maximum.(c) Finish:The understructure, after pre-treatment, is coated with final finish consisting of epoxy polyester powder coat of approved color & shade with a Dry Film Thickness of minimum 40 microns. 54 Movements of the System:Push-Pull Configuration (TYPE-P1/TYPE-P2): Movement of units achieved by pushing or pulling a pair of ‘C type plastic handles’ (mounted on SL & TM units). These handles are rigidly fixed at an ergonomically suitable height on side of each moving body. Each movable body also has an understructure with 4 nos. of antifriction ball bearings for rolling on channels. The twin moving body, i.e. TM, has 4 nos. of bearing fitted horizontally to restrict the lateral movement of the body on rail while the single moving body, i.e. SL, body has 2 nos. of a special anti-tilt bearing assembly fitted to the understructure which not only restricts lateral movement but also prevents SL from toppling.Drive Type Configuration (TYPE-D2/TYPE-D3/TYPE- D4): In case of drive type movement of units is achieved by rotating a PU hand wheel. The hand wheel comprises of a welded metal frame which is then covered by PU using insert-molding process. The metal frame is made of 3 mm thk. HR conforming to IS:2062.The handwheel is connected to the rollers through a ‘Sprocket-Chain’ arrangement mounted on the side of the body. For D3 & D4 type of configurations, the ‘sprocket-chain’ arrangement is replaced by a 2-stage ‘sprocket-chain’ arrangement to accommodate higher weights of the bodies.For D2, each movable understructure is provided with 4 rollers of which 2 are driving and 2 are driven. The driving rollers are connected to the sprocket-chain arrangement through a connector tube. Through this assembly the input from handwheel is transferred to the driving rollers which then move the entire unit along the rails. On LD understructure additional 2 nos. of a special anti-tilt bearing assembly is fitted to the understructure. This prevents lateral movement as well as tilting of body.Similarly, for D3 each movable understructure has 3 driving rollers and 3 driven rollers. LD understructure has 2 nos. of anti-tilt bearing assembly.For D4 each movable understructure has 4 driving rollers and 4 driven rollers. LD understructure has 2 nos. of anti-tilt bearing assembly.The roller assembly comprises of a die-cast step wheel, 2 deep-groove ball bearings and a MS shaft. The step wheel is made of cast steel and is fitted onto the MS shaft using a feather key. The two ball bearings are then fastened on either side of the step wheel using circlips. This entire roller assembly is then snap-fitted into a wheel housing. The wheel housing is fixed in the U-channel of the understructure using machine screws. This wheel-housing is made of engineering plastic material made by injection-molding process. The entire roller assembly is designed to withstand the maximum loads of the body.The ‘sprocket-chain’ arrangement is covered by a 1 mm thk. CRCA sheet Drive Unit Cover with dimensions 1202mm x 398mm x 87mm and is fixed onto the side of the body. The PU handwheel is rigidly fixed at suitable height on side of the body & projects out of cover by another 99.0 mm. Fixed unit (SD) does not have the Drive Unit Cover. 55 Fittings:(a) Push Pull Optimizer Centralized Locking:A Centralized locking arrangement is provided through Locking Stiffener mounted onto back of Single Last unit, i.e. SL body. It gets locked into the channels when all the units are brought together, and the lock is turned. The Recess handle lock is of Godrej make & placed at a height of 940mm from ground level. The locking stiffener is made of 1.2 mm thk conforming to IS:513.(b) Drive Type Optimizer Centralized Locking:Each Drive type unit has a Locking Knob near the Drive wheel for manual locking of individual units when a person is using those units. This prevents other users from accidently moving units while someone is inside. Knob should be rotated to unlock position when units are to be moved again.A centralized locking arrangement is also provided on drive unit cover. A cam lock and lever arrangement is fitted on the drive unit cover of the last movable body, i.e. (LD). After all bodies are brought together, the bodies are locked using their respective knobs. The cam lock is then turned to lock position. This locked cam lock ensures that the knob of the last body remains in the locked position unless the cam lock is unlocked. This in turn ensures that the entire layout remains locked.When the last Body is Twin Drive, i.e. TD, hinged doors are provided for the last body. In this scenario the centralized locking system is fitted on the drive unit cover of the last TD body.(b)Door Locking / handle:Hinged doors have Recessed Die cast Handle cum lock with 3 way locking through a lever & shooting bolts.(c) Fasteners:The nuts & bolts are galvanized / blackodized / Zn Plated.(d) Rail Channels (for Push-pull and Drive type with no platform):It consists of ‘C’ section 2 mm thk HR sheet & Square 25.4mm X 2mm thk ERW tube – both connected by screws. Prior to the grouting of the guide channels with the help of raul plug & screw, ensure the ground is level. The rail channels are of 3 lengths i.e., 800mm, 1600mm and 2400mm.Connection of rail channels: The requirement of rail channels depends on the number of rows of bodies. In any configuration there is only one fixed body (SS/SD). There will be only one movable single body (SM/LD) or no movable single body depending on the layout. The number of twin bodies (TM/TD) depends on the layout and customer. In case of any layout there will always be one 2400mm long rail channel. The 800mm and 1600mm rail channels are connected to the 2400mm rail channel, depending on number of rows. The 2400mm rail channel is connected to 800mm/1600mm rail channel using a Square 19.1mm X 2mm thk ERW tube. This tube is connected to both channels using screws from bottom side.Rail Logic: For each body in the bay there is a corresponding rail. So P1/P2/D2 configuration has 2 rails, D3 configuration has 3 rails and D4 has 4 rails. 56 (e) Label Holder:It is an aluminium extrusion of length 396mm for LD/SD and 796mm for TD, fitted on to front cover of body. The Paper is 300GSM matt milky white sticker paper, to be inserted into the aluminium extrusion. The length of paper is 394mm for LD/SD and 794mm for TD. Over that a transparent plastic of corresponding length of 150-200 micron polythene is to be inserted.(g) Platform option (for drive type only): A Platform option is also provided for drive type optimizer along with Rail channel arrangement. The platform consists of Rail Extrusion which is a thick extrusion on which Rail MS bright bar of sq 25.4mm is firmly fixed from bottom using counter sunk screws. This Rail extrusion arrangement has 3 lengths similar to Rail channel i.e., 800mm, 1600mm and 2400mm.Connection of rail extrusions: The requirement of rail extrusions is same as that of the rail channels. The connection of rail extrusions is done using a metal strip which is screwed on the side of the 2400mm rail extrusion bright bar and 800mm/1600mm rail extrusion bright bar, using CSK screws. The metal strip is made of HR sheet 3 mm thk. conforming to IS:2062.Rail Logic: For each body in the bay there is a corresponding rail. So D2 configuration has 2 rails, D3 configuration has 3 rails and D4 has 4 rails.The platform has wire extrusion with snap cover and a slope extrusion on either side of the platform. It also has 3 lengths similar to the rail extrusion. There are MDF panels of 25mm thickness with 1mm Merino Laminate (AC 3 GRADE 40499 SUEDE), which are placed between the extrusions based on the layout. The AC 3 grade ensures resistance to abrasion caused by moderate to heavy footfall.The logic for platform panels booking is shared in a separate excel file. The logic shared is only up to a configuration for 1LD + 1SD + 6TD. For a layout bigger than that the wooden panels are to be booked through APO. This is applicable only for platform panels and not for rail extrusions.(h) Aisle Space:Ensure a clear aisle space on the Handle / Drive Wheel side of the Optimizer layout is at least 780mm. For comfortable access of items stored in the optimizer, ensure adjacent units can be rolled apart at least 780mm.(i) WeightsDead Weight of the system: (These are Nominal Weights. The Exact Weights may differ slightly. This is Only for Internal Purpose from Loading Point of view)(Total external load & dead weight is spread on 2/3/4 channels placed at a distance apart) 57 OPTIMIZER PLUS-DRIVE TYPE 58 Optz Plus SD2 59 Optz Plus LD2 60 Optz Plus TD2 Solid back panel 61 (1200W, 400D,2361H) 62 CHANNELS (RAILS) 63 Optz Plus D2 CHNL 2400mm 64 OPTIMIZER PLUS-DRIVE TYPE 65 Optz Plus SD2 66 Optz Plus TD2 Solid back panel 67 (1200W, 400D, 2361H) 68 Optz Plus Hinge door Pair 1200mm 2361mm PS 69 CHANNELS (RAILS) 70 Optz Plus D2 CHNL 2400mm 71 Optz Plus D2 CHNL 800mm 72 OPTIMIZER PLUS-DRIVE TYPE 73 Optz Plus SD2 74 Optz Plus TD2 Solid back panel 75 (1200W, 400D, 2361H) 76 Optz Plus Hinge door Pair 1200mm 2361mm PS 77 CHANNELS (RAILS) 78 Optz Plus D2 CHNL 2400mm 79 Optz Plus D2 CHNL 800mm 80 OPTIMIZER PLUS-DRIVE TYPE 81 Optz Plus SD2 82 Optz Plus TD2 Solid back panel 83 (1200W, 400D, 2361H) 84 CHANNELS (RAILS) 85 Optz Plus Hinge door Pair 1200mm 2361mm PS 86 Optz Plus D2 CHNL 2400mm 87 Optz Plus D2 CHNL 800mm 88 OPTIMIZER PLUS-DRIVE TYPE 89 Optz Plus SD2 90 Optz Plus TD2 Solid back panel 91 (1200W, 400D, 2361H) 92 CHANNELS (RAILS) 93 Optz Plus D2 CHNL 2400mm 94 Optz Plus D2 CHNL 800mm 95 OPTIMIZER PLUS-DRIVE TYPE 96 Optz Plus SD2 97 Optz Plus LD2 98 Optz Plus TD2 Solid back panel 99 (1200W, 400D, 2361H) 100 CHANNELS (RAILS) 101 Optz Plus D2 CHNL 2400mm 102 Optz Plus D2 CHNL 1600mm 103 Optz Plus D2 CHNL 800mm 104 OPTIMIZER PLUS-DRIVE TYPE 105 2 Bay Drive Type 1050 SD2 106 2 Bay Drive Type 1050 LD2 107 2 Bay Drive Type 1050 TD2 108 1050W X 400D X 2361H 109 CHANNELS (RAILS) 110 Optz Plus D2 CHNL 2400mm 111 Optz Plus D2 CHNL 800mm 112 OPTIMIZER PLUS-DRIVE TYPE 113 2 Bay Drive Type 1050 SD2 114 2 Bay Drive Type 1050 LD2 115 2 Bay Drive Type 1050 TD2 116 1050W X 400D X 2361H 117 CHANNELS (RAILS) 118 Optz Plus D2 CHNL 2400mm 119 Optz Plus D2 CHNL 1600mm 120 Optz Plus D2 CHNL 800mm 121 OPTIMIZER PLUS-DRIVE TYPE 122 2 Bay Drive Type 1050 SD2 123 2 Bay Drive Type 1050 LD2 124 2 Bay Drive Type 1050 TD2 125 1050W X 400D X 2361H 126 CHANNELS (RAILS) 127 Optz Plus D2 CHNL 2400mm 128 Optz Plus D2 CHNL 1600mm 129 Optz Plus D2 CHNL 800mm 130 OPTIMIZER PLUS-DRIVE TYPE 131 2 Bay Drive Type 1050 SD2 132 2 Bay Drive Type 1050 LD2 133 2 Bay Drive Type 1050 TD2 134 1050W X 400D X 2361H 135 CHANNELS (RAILS) 136 Optz Plus D2 CHNL 2400mm 137 Optz Plus D2 CHNL 800mm 138 OPTIMIZER PLUS-DRIVE TYPE 139 2 Bay Drive Type 1050 SD2 140 2 Bay Drive Type 1050 LD2 141 2 Bay Drive Type 1050 TD2 142 1050W X 400D X 2361H 143 CHANNELS (RAILS) 144 Optz Plus D2 CHNL 2400mm 145 Optz Plus D2 CHNL 800mm 146 OPTIMIZER PLUS-DRIVE TYPE 147 2 Bay Drive Type 1050 SD2 148 2 Bay Drive Type 1050 LD2 149 2 Bay Drive Type 1050 TD2 150 1050W X 400D X 2361H 151 CHANNELS (RAILS) 152 Optz Plus D2 CHNL 2400mm 153 Optz Plus D2 CHNL 1600mm 154 OPTIMIZER PLUS-DRIVE TYPE 155 2 Bay Drive Type 1050 SD2 156 2 Bay Drive Type 1050 LD2 157 2 Bay Drive Type 1050 TD2 158 (1050W, 400D, 2361H) 159 CHANNELS (RAILS) 160 Optz Plus D2 CHNL 2400mm 161 OPTIMIZER PLUS-DRIVE TYPE 162 2 Bay Drive Type 1050 SD2 163 2 Bay Drive Type 1050 LD2 164 2 Bay Drive Type 1050 TD2 165 (1050W, 400D, 2361H) 166 CHANNELS (RAILS) 167 Optz Plus D2 CHNL 2400mm 168 Optz Plus D2 CHNL 1600mm 169 Optz Plus D2 CHNL 800mm 170 OPTIMIZER PLUS-DRIVE TYPE 171 2 Bay Drive Type 900 SD2 172 2 Bay Drive Type 900 LD2 173 2 Bay Drive Type 900 TD2 174 900W X 400D X 2361H 175 CHANNELS (RAILS) 176 Optz Plus D2 CHNL 2400mm 177 Optz Plus D2 CHNL 800mm 178 OPTIMIZER PLUS-DRIVE TYPE 179 2 Bay Drive Type 900 SD2 180 2 Bay Drive Type 900 LD2 181 2 Bay Drive Type 900 TD2 182 900W X 400D X 2361H 183 CHANNELS (RAILS) 184 Optz Plus D2 CHNL 2400mm 185 Optz Plus D2 CHNL 1600mm 186 Optz Plus D2 CHNL 800mm 187 OPTIMIZER PLUS-DRIVE TYPE 188 2 Bay Drive Type 900 SD2 189 2 Bay Drive Type 900 LD2 190 2 Bay Drive Type 900 TD2 191 900W X 400D X 2361H 192 CHANNELS (RAILS) 193 Optz Plus D2 CHNL 2400mm 194 Optz Plus D2 CHNL 1600mm 195 OPTIMIZER PLUS-DRIVE TYPE 196 2 Bay Drive Type 900 SD2 197 2 Bay Drive Type 900 LD2 198 2 Bay Drive Type 900 TD2 199 900W X 400D X 2361H 200 CHANNELS (RAILS) 201 Optz Plus D2 CHNL 2400mm 202 Optz Plus D2 CHNL 1600mm 203 Optz Plus D2 CHNL 800mm 204 OPTIMIZER PLUS-DRIVE TYPE 205 2 Bay Drive Type 900 SD2 206 2 Bay Drive Type 900 LD2 207 2 Bay Drive Type 900 TD2 208 900W X 400D X 2361H 209 CHANNELS (RAILS) 210 Optz Plus D2 CHNL 2400mm 211 Optz Plus D2 CHNL 1600mm 212 Optz Plus D2 CHNL 800mm 213 OPTIMIZER PLUS-DRIVE TYPE 214 2 Bay Drive Type 900 SD2 215 2 Bay Drive Type 900 LD2 216 2 Bay Drive Type 900 TD2 217 900W X 400D X 2361H 218 CHANNELS (RAILS) 219 Optz Plus D2 CHNL 2400mm 220 Optz Plus D2 CHNL 800mm 221 OPTIMIZER PLUS-DRIVE TYPE 222 Optz Plus SD2 223 Optz Plus TD2 Solid back panel 224 (1200W, 400D, 2361H) 225 Optz Plus Hinge door Pair 1200mm 2361mm PS 226 CHANNELS (RAILS) 227 Optz Plus D2 CHNL 2400mm 228 Optz Plus D2 CHNL 800mm 229 OPTIMIZER PLUS-DRIVE TYPE 230 Optz Plus SD2 231 Optz Plus TD2 Solid back panel 232 (1200W, 400D, 2361H) 233 Optz Plus Hinge door Pair 1200mm 2361mm PS 234 CHANNELS (RAILS) 235 Optz Plus D2 CHNL 2400mm 236 Optz Plus D2 CHNL 800mm 237 OPTIMIZER PLUS-DRIVE TYPE 238 Optz Plus SD2 239 Optz Plus TD2 Solid back panel 240 (1200W, 400D, 2361H) 241 Optz Plus Hinge door Pair 1200mm 2361mm PS 242 CHANNELS (RAILS) 243 Optz Plus D2 CHNL 2400mm 244 Optz Plus D2 CHNL 800mm 245 OPTIMIZER PLUS-DRIVE TYPE 246 Optz Plus SD2 247 Optz Plus TD2 Solid back panel 248 (1200W, 400D, 2361H) 249 Optz Plus Hinge door Pair 1200mm 2361mm PS 250 CHANNELS (RAILS) 251 Optz Plus D2 CHNL 2400mm 252 Optz Plus D2 CHNL 800mm 253 OPTIMIZER PLUS-DRIVE TYPE 254 Optz Plus SD2 255 Optz Plus LD2 256 Optz Plus TD2 Solid back panel 257 (1200W, 400D, 2361H) 258 CHANNELS (RAILS) 259 Optz Plus D2 CHNL 2400mm 260 Optz Plus D2 CHNL 1600mm 261 Optz Plus D2 CHNL 800mm 262 OPTIMIZER PLUS-DRIVE TYPE 263 2 Bay Drive Type 1050 SD2 264 2 Bay Drive Type 1050 LD2 265 2 Bay Drive Type 1050 TD2 266 (1050W, 400D, 2361H) 267 CHANNELS (RAILS) 268 Optz Plus D2 CHNL 2400mm 269 Optz Plus D2 CHNL 1600mm 270 Optz Plus D2 CHNL 800mm 271 OPTIMIZER PLUS-DRIVE TYPE 272 2 Bay Drive Type 1050 SD2 273 2 Bay Drive Type 1050 LD2 274 2 Bay Drive Type 1050 TD2 275 (1050W, 400D, 2361H) 276 CHANNELS (RAILS) 277 Optz Plus D2 CHNL 2400mm 278 Optz Plus D2 CHNL 1600mm 279 Optz Plus D2 CHNL 800mm 280 OPTIMIZER PLUS-DRIVE TYPE 281 2 Bay Drive Type 1050 SD2 282 2 Bay Drive Type 1050 LD2 283 2 Bay Drive Type 1050 TD2 284 (1050W, 400D, 2361H) 285 CHANNELS (RAILS) 286 Optz Plus D2 CHNL 2400mm 287 Optz Plus D2 CHNL 800mm 288 OPTIMIZER PLUS-DRIVE TYPE 289 2 Bay Drive Type 1050 SD2 290 2 Bay Drive Type 1050 LD2 291 2 Bay Drive Type 1050 TD2 292 (1050W, 400D, 2361H) 293 CHANNELS (RAILS) 294 Optz Plus D2 CHNL 2400mm 295 Optz Plus D2 CHNL 1600mm 296 OPTIMIZER PLUS-DRIVE TYPE 297 2 Bay Drive Type 1050 SD2 298 2 Bay Drive Type 1050 LD2 299 2 Bay Drive Type 1050 TD2 300 (1050W, 400D, 2361H) 301 CHANNELS (RAILS) 302 Optz Plus D2 CHNL 2400mm 303 OPTIMIZER PLUS-DRIVE TYPE 304 2 Bay Drive Type 1050 SD2 305 2 Bay Drive Type 1050 LD2 306 2 Bay Drive Type 1050 TD2 307 (1050W, 400D, 2361H) 308 CHANNELS (RAILS) 309 Optz Plus D2 CHNL 2400mm 310 Optz Plus D2 CHNL 1600mm 311 Optz Plus D2 CHNL 800mm 312 OPTIMIZER PLUS-DRIVE TYPE 313 2 Bay Drive Type 900 SD2 314 2 Bay Drive Type 900 LD2 315 2 Bay Drive Type 900 TD2 316 900W X 400D X 2361H 317 CHANNELS (RAILS) 318 Optz Plus D2 CHNL 2400mm 319 Optz Plus D2 CHNL 800mm 320 OPTIMIZER PLUS-DRIVE TYPE 321 2 Bay Drive Type 900 SD2 322 2 Bay Drive Type 900 LD2 323 2 Bay Drive Type 900 TD2 324 900W X 400D X 2361H 325 CHANNELS (RAILS) 326 Optz Plus D2 CHNL 2400mm 327 Optz Plus D2 CHNL 1600mm 328 Optz Plus D2 CHNL 800mm 329 OPTIMIZER PLUS-DRIVE TYPE 330 2 Bay Drive Type 900 SD2 331 2 Bay Drive Type 900 LD2 332 2 Bay Drive Type 900 TD2 333 900W X 400D X 2361H 334 CHANNELS (RAILS) 335 Optz Plus D2 CHNL 2400mm 336 Optz Plus D2 CHNL 1600mm 337 OPTIMIZER PLUS-DRIVE TYPE 338 2 Bay Drive Type 900 SD2 339 2 Bay Drive Type 900 LD2 340 2 Bay Drive Type 900 TD2 341 900W X 400D X 2361H 342 CHANNELS (RAILS) 343 Optz Plus D2 CHNL 2400mm 344 Optz Plus D2 CHNL 1600mm 345 Optz Plus D2 CHNL 800mm 346 OPTIMIZER PLUS-DRIVE TYPE 347 2 Bay Drive Type 900 SD2 348 2 Bay Drive Type 900 LD2 349 2 Bay Drive Type 900 TD2 350 900W X 400D X 2361H 351 CHANNELS (RAILS) 352 Optz Plus D2 CHNL 2400mm 353 Optz Plus D2 CHNL 1600mm 354 Optz Plus D2 CHNL 800mm 355 OPTIMIZER PLUS-DRIVE TYPE 356 2 Bay Drive Type 900 SD2 357 2 Bay Drive Type 900 LD2 358 2 Bay Drive Type 900 TD2 359 900W X 400D X 2361H 360 CHANNELS (RAILS) 361 Optz Plus D2 CHNL 2400mm 362 Optz Plus D2 CHNL 800mm 363 OPTIMIZER PLUS-DRIVE TYPE 364 Optz Plus SD2 365 Optz Plus TD2 Solid back panel 366 (1200W, 400D, 2361H) 367 Optz Plus Hinge door Pair 1200mm 2361mm PS 368 CHANNELS (RAILS) 369 Optz Plus D2 CHNL 2400mm 370 Optz Plus D2 CHNL 800mm 371 OPTIMIZER PLUS-DRIVE TYPE 372 Optz Plus SD2 373 Optz Plus TD2 Solid back panel 374 (1200W, 400D, 2361H) 375 Optz Plus Hinge door Pair 1200mm 2361mm PS 376 CHANNELS (RAILS) 377 Optz Plus D2 CHNL 2400mm 378 Optz Plus D2 CHNL 800mm 379 OPTIMIZER PLUS-DRIVE TYPE 380 Optz Plus SD2 381 Optz Plus TD2 Solid back panel 382 (1200W, 400D, 2361H) 383 Optz Plus Hinge door Pair 1200mm 2361mm PS 384 CHANNELS (RAILS) 385 Optz Plus D2 CHNL 2400mm 386 Optz Plus D2 CHNL 800mm 387 OPTIMIZER PLUS-DRIVE TYPE 388 Optz Plus SD2 389 Optz Plus TD2 Solid back panel 390 (1200W, 400D, 2361H) 391 Optz Plus Hinge door Pair 1200mm 2361mm PS 392 CHANNELS (RAILS) 393 Optz Plus D2 CHNL 2400mm 394 Optz Plus D2 CHNL 800mm 395 OPTIMIZER PLUS-DRIVE TYPE 396 Optz Plus SD2 397 Optz Plus LD2 398 Optz Plus TD2 Solid back panel 399 (1200W, 400D, 2361H) 400 CHANNELS (RAILS) 401 Optz Plus D2 CHNL 2400mm 402 Optz Plus D2 CHNL 1600mm 403 Optz Plus D2 CHNL 800mm 404 OPTIMIZER PLUS-DRIVE TYPE 405 2 Bay Drive Type 1050 SD2 406 2 Bay Drive Type 1050 LD2 407 2 Bay Drive Type 1050 TD2 408 (1050W, 400D, 2361H) 409 CHANNELS (RAILS) 410 Optz Plus D2 CHNL 2400mm 411 Optz Plus D2 CHNL 1600mm 412 Optz Plus D2 CHNL 800mm 413 OPTIMIZER PLUS-DRIVE TYPE 414 2 Bay Drive Type 1050 SD2 415 2 Bay Drive Type 1050 LD2 416 2 Bay Drive Type 1050 TD2 417 (1050W, 400D, 2361H) 418 CHANNELS (RAILS) 419 Optz Plus D2 CHNL 2400mm 420 Optz Plus D2 CHNL 1600mm 421 Optz Plus D2 CHNL 800mm 422 OPTIMIZER PLUS-DRIVE TYPE 423 2 Bay Drive Type 1050 SD2 424 2 Bay Drive Type 1050 LD2 425 2 Bay Drive Type 1050 TD2 426 (1050W, 400D, 2361H) 427 CHANNELS (RAILS) 428 Optz Plus D2 CHNL 2400mm 429 Optz Plus D2 CHNL 800mm 430 OPTIMIZER PLUS-DRIVE TYPE 431 2 Bay Drive Type 1050 SD2 432 2 Bay Drive Type 1050 LD2 433 2 Bay Drive Type 1050 TD2 434 (1050W, 400D, 2361H) 435 CHANNELS (RAILS) 436 Optz Plus D2 CHNL 2400mm 437 Optz Plus D2 CHNL 1600mm 438 OPTIMIZER PLUS-DRIVE TYPE 439 2 Bay Drive Type 1050 SD2 440 2 Bay Drive Type 1050 LD2 441 2 Bay Drive Type 1050 TD2 442 (1050W, 400D, 2361H) 443 CHANNELS (RAILS) 444 Optz Plus D2 CHNL 2400mm 445 OPTIMIZER PLUS-DRIVE TYPE 446 2 Bay Drive Type 1050 SD2 447 2 Bay Drive Type 1050 LD2 448 2 Bay Drive Type 1050 TD2 449 (1050W, 400D, 2361H) 450 CHANNELS (RAILS) 451 Optz Plus D2 CHNL 2400mm 452 Optz Plus D2 CHNL 1600mm 453 Optz Plus D2 CHNL 800mm 454 OPTIMIZER PLUS-DRIVE TYPE 455 2 Bay Drive Type 900 SD2 456 2 Bay Drive Type 900 LD2 457 2 Bay Drive Type 900 TD2 458 900W X 400D X 2361H 459 CHANNELS (RAILS) 460 Optz Plus D2 CHNL 2400mm 461 Optz Plus D2 CHNL 800mm 462 OPTIMIZER PLUS-DRIVE TYPE 463 2 Bay Drive Type 900 SD2 464 2 Bay Drive Type 900 LD2 465 2 Bay Drive Type 900 TD2 466 900W X 400D X 2361H 467 CHANNELS (RAILS) 468 Optz Plus D2 CHNL 2400mm 469 Optz Plus D2 CHNL 1600mm 470 Optz Plus D2 CHNL 800mm 471 OPTIMIZER PLUS-DRIVE TYPE 472 2 Bay Drive Type 900 SD2 473 2 Bay Drive Type 900 LD2 474 2 Bay Drive Type 900 TD2 475 900W X 400D X 2361H 476 CHANNELS (RAILS) 477 Optz Plus D2 CHNL 2400mm 478 Optz Plus D2 CHNL 1600mm 479 OPTIMIZER PLUS-DRIVE TYPE 480 2 Bay Drive Type 900 SD2 481 2 Bay Drive Type 900 LD2 482 2 Bay Drive Type 900 TD2 483 900W X 400D X 2361H 484 CHANNELS (RAILS) 485 Optz Plus D2 CHNL 2400mm 486 Optz Plus D2 CHNL 1600mm 487 Optz Plus D2 CHNL 800mm 488 OPTIMIZER PLUS-DRIVE TYPE 489 2 Bay Drive Type 900 SD2 490 2 Bay Drive Type 900 LD2 491 2 Bay Drive Type 900 TD2 492 900W X 400D X 2361H 493 CHANNELS (RAILS) 494 Optz Plus D2 CHNL 2400mm 495 Optz Plus D2 CHNL 1600mm 496 Optz Plus D2 CHNL 800mm 497 OPTIMIZER PLUS-DRIVE TYPE 498 2 Bay Drive Type 900 SD2 499 2 Bay Drive Type 900 LD2 500 2 Bay Drive Type 900 TD2 501 900W X 400D X 2361H 502 CHANNELS (RAILS) 503 Optz Plus D2 CHNL 2400mm 504 Optz Plus D2 CHNL 800mm 505 Electrical Works 506 Wiring point for light in 1.5 sq. mm.FRLSHPVC insulated multistrandsingle core copper conductor cable (drawn through existing concealed steel conduit) and 5 Amp.flush type switch & ceiling rose/angle/batten holder fixed with 3mm thick phenolic laminated backalite sheet with brass machine screws andcup washers mounted over existing M.S. switch board box/ junction box with supply of all material, labour & T&P etc. required for proper completion of the work as directedat site by the Engineer in charge. 174B/2018 507 Same asin item no.174 (B)but for ceiling fan. 177B/2018 508 Wiring point for exhaust fan in 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable (drawn through existing concealed conduit) and 15 Amp flush type switch & ceilingrose fixed with 3 mm thick phenolic laminatedbackalite sheet with brass machine screws and cup washers mounted over the existing M.S. box/ Junction box requiredfor proper completion of the work as directed at site by the Engineer in charge. 179B/2018 509 Wiringpointforplugwith 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable inheavyguagerigidsteel conduit partly concealed in wall and partly laid in slab alongwith the reinforcementbefore concreting, complete with14 SWG copper earth continuity wire and piano typeswitch and socket etc., complete in all respect including matching colour wash. 141B/2018 510 Supply and fixing of switch box 100 x 100 x 50 mm size of approved make made up of 1.0 mm thickISI Marked G.P.sheet All 4 corners folded & spot welded for screw and holes plugged with PVC Nylon Caps . Two or more holes for pipe entryof 25.4 mm on upper and lower sides of the box. Holes shuld be semi-shuttered type and fitted with heavy brass Earth Piller duly screwed & brand name should be embossed. Box flushed in wall including cutting of brick work, fixing it to the level with cement sand mortar, including matching colour wash with s/o all materials, labour and T&P required for proper completion of work as directed at site by the Engineer in charge. 159/2018 511 Supply and wiring of3 number 4 sq. mm. FRLSH PVC insulated 1100V grade multistrand single core copper conductor cablein 25 mm dia heavy guage rigid steel conduit concealed in wall with two number14SWG copper earth continuity wire, including matching colour wash etc, complete in all respect. 512 Supply and wiring of 3 number 6 sq. mm. FRLSH PVC insulated 1100V grade multistrand single core copper conductor cable in 25 mm dia heavy guage rigid steel conduit concealed in wall with twonumber 14SWG copper earth continuity wire, including matching colour wash etc, complete in all respect. 513 S&F of 0.5 Amp to 5 Amp. SP MCB (10KA) C Curve. CAT A 514 S&F of 6 Amp to 32 Amp. SPMCB (10 KA) C Curve. CAT A 515 S&F of50 Ampto63Amp.SPMCB(10KA)1003B/2018 516 S&F of 63 Amp.T.P. Isolator. 1006B/2018 517 S&F surface/flush mounting 8ways SPN distribution board with additional metal door without MCB complete in all respect, as directedbyEngineer in charge. 1024A/2018 518 S & F surface/Flush mounting 6waysV TPN distribution board without additional Door without MCB complete in all respect,as directed at site byEngineer in charge. 1027B/2018 519 Supply and erection of factory fabricated and wired metal clad dust and vermin proof floor mounting panel TPN switch board complete with the following HRC type heavy duty TPN fuse switches with fuses and instrument chamber etc. complete in all respects. The instrument chamber shall be separate and shall comprise of flush type ammeter, voltmerer, selector switches for ammeter and voltmeter, instrument fuses, current transormer etc. The board shall have suitable capacity electroytic alumininum busbars as per IS8623 istulate with heat shrink sleeving and mountendon non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches shall be complete with suitable cable end boxes, reverse entery boxes in case of pedestaal type, cable sockets, compression glands and indicating lamp on incoming etc. 520 The job includes the grounting of the board as per direction of Engineer-in-Charge. All coutgoing switches of 100 Amp. and above will be provided with ampere metre current transformers and selector switches and instrument fuses etc. The switches board shall be fabricated with CRCA sheet with a minimum thickness of 1.6 mm/2 mm. Cubicle type switch board shall be of cat A B & B-II and pedestal type for Cat-B and C only. 521 Incoming 522 100 Amp. TPN-1 No 523 Outgoing 524 63 Amp. TNP-2 Nos. 525 Cat. B. Cubicle Type 526 Supply Installation Testing & Commissioning of 10kW 24V Power Backup System with 1/2 Hour Battery Backup.The system Rating : 10kWIncoming : 230V AC +/- 10%Out Put : 24V DC +/- 1%Incoming Current Rating : 60A (Max)Outgoing Current Rating : 420A (6 Nos. x 70A)Backup : Battery BackpBackup Time : 30 MinuteIncoming Breaker : 63A DP MCCBOutput Breaker : 6 Nos. 100A DP MCB/MCCBEnclosre : CRCA Sheet Encosure Enclosre Painting : Powder Coated Painting after 7 Tank Sheet Treatement Process 527 Supply, Installation, Testing and Commissioning of 1200 mm sweep, DC Ceiling/Wall Fans 528 Supply, installation and testing of DC Exhaust fan 529 Supply, installation and testing of DC lights
Contract Date : Ref. Documents   |   Contract Value : Ref. Documents
BRR : 8340036 Tender For Repair Replacement Of Ber Lifts In Kolkata Mil Station.; 1 NOTE (Applicable for all items) :-(i) The bidders/contractorsare advised to read tender document & all corrigendum / amendments and General conditions of contracts before entrying/quoting the rates.SCHEDULE A PART-I (B/R PORTION) 2 Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc complete all as specified and directed 3 All as per item No. 1.001 above but 5 storey to 8 storey 4 All as per item No. 1.001 above but 9 storey to 12 storey 5 Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.(upto 4 storey) 6 All as per item No. 1.004 above but 5 storey to 8 storey 7 All as per item No. 1.004 above but 9 storey to 12 storey 8 Taking down cement plaster on brick or stone wall surfaces including glazed tiles wherever exists including raking out joints, hacking for key and scrubbing down with water complete all as specified and as directed.( upto 4 storey) 9 All as per item No. 1.007 above but 5 storey to 8 storey 10 All as per item No. 1.007 above but 9 storey to 12 storey 11 Taking down chowkhats or frames with shutters ( without taking off shutters from the frames) area exc 1.5 sqm but not exc 4 sqm eachcomplete all as specified and directed (up to 4 storey high building). 12 All as per item No. 1.010 above but 5 storey to 8 storey 13 All as per item No. 1.010 above but 9 storey to 12 storey 14 Taking down chowkhats or frames with shutters ( without taking off shutters from the frames) area n exc 1.5 sqm complete all as specified and directed (up to 4 storey high building). 15 Material and labour for 10 mm thick screed bed in cement mortar 1:4 mixed with Water Proofing Compound as per manufactures instructions and top surface finished even and smooth to recieve water proofing treatment complete all as specified and as directed .Note : Water Proofing Compound shall be measured and paid separately. 16 Material and labour for 18-20 mm thck machine cut Kota Stone slab flooring set and jointed with grey cement slurry mixed withpigment to match the shade of the slab including rubbing and polishing, laid over and including 15 mm thick screed bed in cement mortar (1:4) complete all as specified and as directed(upto 4 storey) 17 All as per item No. 1.015 above but 5 storey to 8 storey 18 All as per item No. 1.015 above but 9 storey to 12 storey 19 Material and labour for coloured non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match in floors etc. set and jointed in neat cement slurry over a bedding layer of scread bed 15 mm thick in CM 1:4 and pointed in white/colour cement to match.(upto 4 storey) 20 All as per item No. 1.018 above but 5 storey to 8 storey 21 All as per item No. 1.018 above but 9 storey to 12 storey 22 Material and labour for Granite (of any type) tiles 20 mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing in wall, jambs , pillars etc complete with 10 mm cement plaster 1:4 all as spdand directed EIC.(upto 4 storey) 23 All as per item No.1.021 above but 5 storey to 8 storey 24 All as per item No.1.021 above but 9 storey to 12 storey 25 Chipping of unsound /weak concrete materials from slabs , beams, columns ,lintel,chajja, fin , facia etc. by any meansincluding tapering all edges, making square shoulders of cavities air or sand blasting etc and cleaning of exposed concrete surface of lightly picking materials by air blasting or sand blasting incl foreign matrials , loose concrete/aggregate etcand disposal of all debris out of MOD land and complete all as specifiedandas directedby Engr-in-Charge. for 50mm average thickness for slabs/Chajja/beams 26 All as per item No.24 above but 5 storey to 8 storey 27 All as per item No.24 above but 9 storey to 12 storey 28 Removing of concrete all around reinforcement including from behind the reinforcing bars to give an average 25mm (but not less than 15mm clear air gap) by manual methods (using wire brushing, chiselling etc) and applying alkaline rust removing chemical followed by removing rust including from behind the reinforcing bars by emery paper and cleaning the area throughly by water and allow it to dry all as per manufacturer,s instruction to give it a totally rust free finished steel surfaceupto 4 storey complete all as specified and directed. 29 All as per item No 1.027 above but 5 storey to 8 storey 30 All as per item No 1.027 above but 9 storey to 12 storey 31 Material and labour for providing single coat of epoxy bond adhesive of prepared non metallic surface (existing surface) and applying by brush all as per manufactures instruction/specification. The bonding agent shall have minimum compressive strength of 40 N/Sqmm upto 4 storey complete all as specified and directed. 32 All as per item No1.030 above but 5 storey to 8 storey 33 All as per item No 1.030 above but 9 storey to 12 storey 34 Supply and application of Epoxy Zinc rich primer on the prepared steel surface by brush the primer shall have a minimium specific gravity 1.75 minimum weight film thickness/coat 40 microns and minimum adhesive bond strength with steel is 1.5N/mm2upto 4 storey High complete all as specified and directed by Engr-in-charge. 35 All as per item No 1.033 above but 5 storey to 8 storey 36 All as per item No 1.033 above but 9 storey to 12 storey 37 Material and labourfor providing and placing in position free flow non shrink cementitious micro concrete of Grade of M-50 to the effected beam, column etc. The micro concrete shall have a minimium 1 day compressive strength of 10 Mpa and 28 days strength of 50 Mpa, minimum tensile strength 5N/mm2 @ 28 days, minimium flextural strength 5N/mm2 @ 28days and complete all as specified and directed by Engr-in-Charge ofColumn, upto 4 storey High. 38 All as per item No 1.036 above but 5 storey to 8 storey 39 Supply, mixing and application two component structural grade polymer modified reinstatement morter, where local spalling has taken place or shuttering is not possible. The morter can be applying in layers not exceeding 6mm thick in each layer in and upto any thickness in smaller vertical pockets and upto any thickness in horizontal applications. The mortar should have a minimium compressive strength 12N/mm2 in 1 day and 45N/mm2 in 28 days. Minimum flexural strength should be 8N/mm2 in 28 days. A modified styrene butadience emulsion for use as a bonding aid and gauging liquid for cementious system to be mixed with cement slurry before the application of modified polymer mortar to be used @ 6 ltr/bag of cement. The bonding agent should have minimium compressive strength 24N/mm2. Minimum tensile strength 3.5N/mm2, minimium flexural strength 6.5N/mm2 complete all as specified and directedby the Engr-in-charge upto 25 mm average thickness and upto 4 storey High. Make :- Sika/Fosroc NOTE :- Cement and sand morter in proportion of 1:2 graded coarse sand with polymer admixed in proportions approved by Engr-in-charge. 40 All as per item No 1.038 above but 5 storey to 8 storey 41 All as per item No 1.038 above but 9 storey to 12 storey 42 Material and labour for applying polymer modified cement mortar rendering 15 mm thick in CM 1:3 on wall duly mixing polymer modifier Nitobond SBR of M/s Forsoc Chemical India (Pvt) Ltd or Hind Styrene BR of Hindcon Chemical Ltd or equivalent make of M/s Pidilite Industries @ 7 Litre per bag of cementcomplete finished even and smooth without using extra cement complete all as specified and as per manufacturers specification. 43 All as per item No.1.041 above but 5 storey to 8 storey 44 All as per item No.1.041 above but 9 storey to 12 storey 45 Material and labour for introducing new reinforcement bars for structural connection in RCC beams, columns, lintel and slabs including power drilling holes of appropriate diameters in reinforced or plain cement concrete to a minimum depth of 150mm and upto 200mm including power drilling, fixing the reinforcement in position using epoxy, cleaning of loose dust by blowing air, sealing with epoxy cartridges etc all as specified and directed by Engr-in-charge. upto 12 mm dia bar upto 4 storey High. 46 All as per item No 1.044 above but 5 storey to 8 storey 47 All as per item No 1.044 above but 9 storey to 12 storey 48 Material and labour for applying curing compound over concrete surfaces as per manufactures instruction complete all as specified and directed by Engr-in-charge upto 4 storey High. 49 All as per item No 1.047 above but 5 storey to 8 storey 50 All as per item No 1.047 above but 9 storey to 12 storey 51 Supply and fixingpowder coated anodised aluminium frame for doors,windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified 52 Supply and fixing powder coated anodised aluminium window and ventilator shutters, side hung type with sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips,rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays hinges and handles (2 no.) etc with 4mm thick tinted/frosted glass ordinary quality as per manufactures instruction complete all as specified 53 Supply and fixingAnodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. 54 Material and labour for 25mm thick cement concrete type B-0, 1:2:4 using 12.5mm graded aggregate in sub bases of floors complete all as specified and directed. 55 Material and labour for Water Proofing Treatment on existing cleaned RCC Roof with the following Specifications and Manufacturers instructions, complete all as specified and as directed:-(a) Preparing fully dried plastered surface as per IS:3067-1966, for further treatment.(b) Applying Bitumen Primer conforming to IS-3384-1986, over the Cleaned Plastered Surface @ 0.3 Litre per Sqm.(c) Applying a layer of APP based Polymeric Membrance; 3.0mm thick (minimum) weighing 3.50 Kilogram per Square Meter (reinfored) with Polyster Non Woven Fabric weighing not less than 160 Grams per Square Metre by Torch application. The overlaps shall be minimum 100mm on the Transverse direction and 75mm on Longitudinal direction.(d) Applying one coat of Aluminium Paint @ 0.10 Litre per Sqm over APP based Polymeric Membrane. 56 Supply only integral water proofing compound (ISIgrade only) 57 Material and labour forcutting out cracks to V section in existing roofs of terracing cleaning out, wetting, grouting, with cement sand slurry 1:3 complete all as specified and as directed 58 Material and labour forTMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.(upto 04 storey) 59 All as per item No. 1.057above but 5 storey to 8 storey 60 All as per item No. 1.057 above but 9 storey to 12 storey 61 All as per item No. 1.057 above but 6 to 8mm dia n stirrups, spacers and binders complete all as specified and as directed. (upto 04 storey) 62 All as per item No. 1.060 above but 5 storey to 8 storey 63 All as per item No. 1.060 above but 9 storey to 12 storey 64 Material and labour brick work with fly ash brick straight or curved on plan exc. 6m mean radius, built in cement mortar (1:6) completeall as specified and directed by Engineer-in-Charge. 65 All as per item No. 1.063 above but 5 storey to 8 storey 66 All as per item No. 1.063 above but 9 storey to 12 storey 67 M & L for brick work with fly ash bricks old size, straight or curved on plan to any radius in half brick thick walls built in cement mortar (1:4) complete all as specified and directed. 68 All as per item No. 1.066 above but 5 storey to 8 storey 69 All as per item No. 1.066 above but 9 storey to 12 storey 70 Demolition of PCC in ground floorand pavings not exc 15 cm thickness below or above ground level complete all as specified and directed. 71 All as per item No. 1.069 above but 5 storey to 8 storey 72 All as per item No. 1.069 above but 9 storey to 12 storey 73 Demolition of cement concrete (reinforced) in ground floor and paving not exceeding 15 cm thick (below or above G.L) all as specified and directed 74 All as per item No. 1.072 above but 5 storey to 8 storey 75 All as per item No. 1.072 above but 9 storey to 12 storey 76 Material and labour for Any thick PCC (1:3:6) type C2(20 mm graded stone agg) as in flooring, finished even and smooth with using extra cementcomplete all as specified and directed. 77 All as per item No. 1.075 above but 5 storey to 8 storey 78 All as per item No. 1.075 above but 9 storey to 12 storey 79 Material and labour for10 mm thick rendering in cement mortar (1:6) to brick or concrete wall surfaces, finished even and smooth without using extra cement all as specified and as directed by the Engineer-in-Charge. 80 Material and labour for Rendering on ceiling 5 mm thick in cement mortar (1:3) onof concrete surface finished even and smooth with out using extra cement complete all as specified and directed. 81 All as per item No. 1.079 above but 5 storey to 8 storey 82 All as per item No. 1.079 above but 9 storey to 12 storey 83 Material and labour for 15mm thick plastering on fair face of brick wall and concrete surface in CM (1:4) surface finished even and fair complete all as specified and directed. 84 All as per item No. 1.082 above but 5 storey to 8 storey 85 All as per item No. 1.082 above but 9 storey to 12 storey 86 Material and labour for Complete removal of existing treatment of old surface and applying two coat of OBD incl 1mm thick birla white putty etc all as specified and directed complete all as specified and directed 87 All as per item No. 1.085 above but 5 storey to 8 storey 88 All as per item No. 1.085 above but 9 storey to 12 storey 89 Material and labour for prepration of new plasterd surface and applying two coat of oil Emulsion distamper etc complete all as specified and directed. 90 Material and labour for one coat of white wash on old decorated surface of internal walls incl preparation complete all as specified and directed by Engr-in-Chargeupto 4 storey bldg. 91 All as per item No. 1.089 above but 5 storey to 8 storey 92 All as per item No. 1.089 above but 9 storey to 12 storey 93 Material and labour for one coat of white wash on old decorated surface of ceiling incl preparation complete all as specified and directed by Engr-in-Chargeupto 4 storey bldg. 94 All as per item No. 1.092 above but 5 storey to 8 storey 95 All as per item No. 1.092 above but 9 storey to 12 storey 96 Material and labour for three coat of white wash on new decorated surface of internal walls incl preparation complete all as specified and directed by Engr-in-Charge upto 4 storey bldg. 97 All as per item No. 1.095 above but 5 storey to 8 storey 98 All as per item No. 1.095 above but 9 storey to 12 storey 99 Material and labour for three coat of white wash on new decorated surface of ceiling incl preparation complete all as specified and directed by Engr-in-Charge. 100 All as per item No. 1.098 above but 5 storey to 8 storey 101 All as per item No. 1.098 above but 9 storey to 12 storey 102 Taking out/Stripping of old Roof treatment membranes/Tar felt incl layer ofcement mortar of any type carefully from roof surfaces (without damaging roof ) and incl preparation of old roof surfaces by picking, sweeping, cleaning and washing down with water to remove dust & receive new treatment complete all as specified and directed. 103 Material and labour for 100mm thick PCC 1:2:4 type B-1 using 20 mm graded aggregate finished even and smooth finishing cement concrete surface even and smooth without using extra cement complete all as specified. 104 Supply and fixing in repair 30 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial typecomplete all as spd and directed. (Upto 4 storey bldg) 105 All as per item No. 1.103 above but 5 storey to 8 storey 106 All as per item No. 1.103 above but 9 storey to 12 storey 107 Dismantling wrough iron or mild steel work of any description not otherwise provided for complete all as directed. 108 Supply and fixing in repairs Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete Gauzed with glazing bars, dovetailed or welded complete including taking down old steel window all as specified and as directed by Engineer-in-charge. (Upto 4 storey bldg) 109 All as per item No. 1.107 above but 9 storey to 12 storey 110 Supply and fixingin repairs Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete Gauzed without glazing bars, dovetailed or welded complete including taking down old steel window all as specified and as directed by Engineer-in-charge. 111 Supply and fixing in repair framed work such as grills, gratings, etc. with ends of bars shouldered and /or riveted or forged into spikes, framed guard bars barred iron doors; ladders framed alusters; wald ways; railings; framework of water tanks and similar work confrming to Fe-290 Gde -E 165. 112 Supply and fixing in repair framed work such as grills, gratings, etc. with ends of bars shouldered and /or riveted or forged into spikes, framed guard bars barred iron doors; ladders framed alusters; wald ways; railings; framework of water tanks and similar work confrming to Fe-290 Gde -E 165.(9 storey to 12 storey) 113 Supply and fixing hard drawn steel wire fabric weight exceeding 4.0 Kg/Sqm cut to lengths, bent to shape required and welded to angle /channel complete all as specified and directed by Engineer-in-Charge. 114 Supply and fixing 100 mm long butt hinges medium weight, cold rolled mild steel and fixed complete complete all as spd and directed.(Upto 4 storey bldg) 115 Supply and fixing aluminium anodised handles cast type, anodised 150mm long complete all as spd and directed.(Upto 4 storey bldg) 116 All as per item No. 1.114 above but 5 storey to 8 storey 117 All as per item No. 1.114 above but 9 storey to 12 storey 118 Supply and fixing aluminium anodised tower bolt cast type, anodised 200 mm long complete all as spd and directed.(Upto 4 storey bldg) 119 All as per item No. 1.117 above but 5 storey to 8 storey 120 All as per item No. 1.117 above but 9 storey to 12 storey 121 Supply and fixing 300mm long sliding door bolts with hasp stapple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bots and sliding bolts of extruded or cast aluminium alloy (Upto 4 storey bldg) 122 All as per item No. 1.120 above but 5 storey to 8 storey 123 All as per item No. 1.120 above but 9 storey to 12 storey 124 Supply and fixing Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws etc, upto 4 storey bldg all as spd and directedby the Engr-in-charge 125 All as per item No. 1.123 above but 5 storey to 8 storey 126 All as per item No. 1.123 above but 9 storey to 12 storey 127 Material and labour for Green / White marble work 18 to 20 mm thick (table rubbed and polished ) in steps, jambs, piller, window cills, cooking platform and including 15mm screedbed of cement mortar (1:4) including pointing with white cement (1:2) using marble dust with admixture pigment to match with marble shade complete all as specified and directed. 128 All as per item No. 1.126 above but 5 storey to 8 storey 129 All as per item No. 1.126 above but 9 storey to 12 storey 130 Supply and fixing 4mmplain sheet glass ordinary quality and glazed with oil putty or fixed with fillets 2nd class hard wood of sectional area of glass not exc 0.5 sqm each pane. (Upto 4 storey bldg) 131 All as per item No. 1.129 above but 5 storey to 8 storey 132 All as per item No. 1.129 above but 9 storey to 12 storey 133 Hacking out old brokenglass (any thickness, size, quality or description) from wooden frames/steel/aluminiumframes glazed with putty or fixed with beads complete. 134 Supply and fixingstainless steel wire cloth, 0.36 mm dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks, or galvanized wire staples incl of dismentling all as directed by Engr in charge.(Upto 4 storey bldg) 135 All as per item No. 1.133 above but 5 storey to 8 storey 136 All as per item No. 1.133 above but 9 storey to 12 storey 137 Material and labour for Pressed steel frames for doors with one or more rebates size of frame 105 x 60 mm including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed complete all as specified and directed.Note:- Pressed Steel Frame should be filled with PCC 1:3:6 Type C-0 (Using 12.50mm graded stone aggregate) and cost of PCC shall be deemed included in quoted rate 138 All as per item No. 1.136 above but 5 storey to 8 storey 139 All as per item No. 1.136 above but 9 storey to 12 storey 140 M&L for PCC 1:3:6type C-1 using 20mm graded stone agg as in bedblocks/hold fast complete all as specified and directed 141 All as per item No. 1.139 above but 5 storey to 8 storey 142 All as per item No. 1.139 above but 9 storey to 12 storey 143 Demolition of brick work or stone masonary built in cement mortor including all quoins & jambs etc. complete all as specified and directed 144 All as per item No. 1.142 above but 5 storey to 8 storey 145 All as per item No. 1.142 above but 9 storey to 12 storey 146 Cutting opening in cement concrete walls (any description)With or without reinforcementfor door, window and other openings(with or without reveals) or enlarging existing openings, including trimming surfaces to receive rendering, etc.(upto 4 storey) 147 All as per item No. 1.145 above but 5 storey to 8 storey 148 All as per item No. 1.145 above but 9 storey to 12 storey 149 Cutting opening in cement concrete walls (any description) With cut of reinforcement for door, window and other openings(with or without reveals) or enlarging existing openings, including trimming surfaces to receive rendering, etc.(upto 04 storey) 150 All as per item No. 1.148 above but 5 storey to 8 storey 151 All as per item No. 1.148 above but 9 storey to 12 storey 152 M&L for RCC(Nominal Mix) in type-A1 1:1.5:3 (20mm graded aggregate) Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specfified and directed 153 All as per item No. 1.151 above but 5 storey to 8 storey 154 All as per item No. 1.151 above but 9 storey to 12 storey 155 Use and waste formwork square, rectangular or ploygonal fair finished surfaces to slides of pillars, post, struts, piers, columns and stanchions complete all as specified. 156 All as per item No. 1.154 above but 5 storey to 8 storey 157 All as per item No. 1.154 above but 9 storey to 12 storey 158 Use and waste for formwork to side and soffits of floor or roof beams, beam haunching, girders, bressummers, lintel, cantilevers, shelves incl support overhangs etc also splays between floors and beams etc all as sped & directed for rough finished surfaces including edges complete all as specified and directed. 159 M&L for two coats of synthetic enamel paint over a coat of pink primer areaexc.10cm width or girthover new wooden surfacesincluding preparationof surface complete complete in all respect as spd 160 All as per item No. 1.158 above but 5 storey to 8 storey 161 All as per item No. 1.158 above but 9 storey to 12 storey 162 M&L for one coat of synthetic enamel paint on oldwooden surfacesincluding preparationof surface complete complete in all respect as specified (up 9 to 12storey High of building) 163 Material & labour preparation of new steeland iron surfaces of any description areaexc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat ofred oxide and zinc chrome primer,complete in all respect as specified. 164 All as per item No.1.162 above but 5 storey to 8 storey 165 All as per item No.1.162 above but 9 storey to 12 storey 166 Material and labour forPreparing new plastering Surfaces of wall applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade(Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces all as specified and directed. 167 Material and labour for complete removal of old Surfaces of wall applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade(Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces all as specified and directed. 168 All as per item No.1.166 above but 5 storey to 8 storey 169 All as per item No.1.166 above but 9 storey to 12 storey 170 Supply and fixing Joist, channel, angle, or tee sections,fixed independently, without connecting plates, etc. Fe 410 W (Gde-E-250) quality A etc all as sped & directed 171 All as per item No.1.169 above but 5 storey to 8 storey 172 All as per item No.1.169 above but 9 storey to 12 storey 173 Supply and fixing Plates (plain or chequered) channels. Square cut or notched (ordinary and counter sunk) forming holes, without any attachment (upto 04 storey) 174 All as per item No. 1.172 above but 5 storey to 8 storey 175 All as per item No. 1.172 above but 9 storey to 12 storey 176 Material & labour for preparation of old steeland iron surfaces of any description areaexc 10 cm width or girth and applying one coat of synthetic enamel paint complete in all respect as specified. 177 All as per item No. 1.175 above but 5 storey to 8 storey 178 All as per item No. 1.175 above but 9 storey to 12 storey 179 SCHEDULE A PART-II ( E/M PORTION) 180 Dismantling and taking down carefully all electrical and mechanical components, assemblies, sub systems such as drives, machine, control panels, lift car, ropes, guides, counterweights, rails, beams and doors, electrrical wirings, control wiring etc. complete of existing beyond economical repairs (BER) lifts including taking down all steel work and components from machine room, lift shaft, lift pit and stacking neatly all retrieved components deposit to departmental store for safe custody and for persual of BOO and making good the disturbed surface in machine room at all landings and in lift door faces to mactch with existing surfaces, all as directed at site by Engr in charge for the foloowing lifts :( Making good to disturbed surfaces will be paid under relevant items listed in B/R works here in after) 181 Dismantling of the old 13 passenger lift machine ( G+12) and all connected accessories and depositing in the mes store yard complete all as specified and directed(Bldg- Hooghly View) 182 Dismantling of the old 10 passenger lift machine ( G+12) and all connected accessories and depositing in the mes store yard completeall as specified and directed(Bldg T V -16) 183 Dismantling of the old 13 passenger lift machine ( G+10) and all connected accessories and depositing in the mes store yard completeall as specified and directed (Bldg- P-197 & 198 BMC) 184 Dismantling of the old 08 passenger lift machine ( G+10) and all connected accessories and depositing in the mes store yard complete all as specified and directed (Bldg no P-197-02, P-198-02 (BMC), Map A-01, Map B -01(Vijay Durg) 185 Dismantling of the old 06 passenger lift machine ( G+10) and all connected accessories and depositing in the mes store yard completeall as specified and directed (Bldg No TV-18) 186 Dismantling of the old 08 passenger lift machine ( G+9) and all connected accessories and depositing in the mes store yard complete all as specified and directed (Bldg No- JSA I & II , Vijay Durg) 187 Dismantling of the old 8 passenger lift machine ( G+7) and all connected accessories and depositing in the mes store yard complete all as specified and directed (Bldg - P-173 BMC) 188 Dismantling of the old 13 passenger lift machine ( G+6) and all connected accessories and depositing in the mes store yard completeall as specified and directed (Bldg No - P-127 (BMC) 189 Dismantling of the old 8 passenger lift machine ( G+6) and all connected accessories and depositing in the mes store yard completeall as specified and directed (Bldg No - Map C (Vijay Durg), T V - 15) 190 Dismantling of the old 6 passenger lift machine ( G+5) and all connected accessories and depositing in the mes store yard complete all as specified and directed (Bldg No - TV 13 and TV-14) 191 Dismantling of the old 8 passenger lift machine ( G+5) and all connected accessories and depositing in the mes store yard complete all as specified and directed (Bldg No - P-1 (Vijay Durg) 192 Dismantling of the old 6 passenger lift machine ( G+4) and all connected accessories and depositing in the mes store yard complete all as specified and directed (Bldg No - O-32 IGS) 193 Dismantling of the old 8 passenger lift machine ( G+2) and all connected accessories and depositing in the mes store yard completeall as specified and directed (Bldg No - MES IB (Vijay Durg) 194 Design supply , install, testing & commissioning of Passengers lift electrically operated, microprocessor controlled, speed 1.5 meter/sec, lift withsingle speed motor 415 volts, 3 phase, AC 50Hz supply conforming to IS-14665, suitable to serve G+12 upper floors with ACVariable Voltage Variable Frequency (VVVF) Regenerative (Cosed loop) drive ( ACD3-MR drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendent, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, emergency automatic rescue device (ARD) system with standby power supply by using suitable capacity maintenance free battery, 3D infra red sensor in full height of door & built in voice announcement system in the carto announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator, announcing system without hand set ( 03 Nos, one each in car, Machine room & near ground floor landing door),Battery operated emergency light & alarm complete all as specified for 13 passenger as per the details given belowcomplete all as specified and directed:-(Location of lift :Hoogly View) 195 (a) Type & capacity: 13 Passenger, 884 Kgs - Gearless (b) Speed:1.5 M/Sec (c) Type of Drive:VVVF Regenerative (Closed Loop)(d) Type of control :Microprocessor based Simplex full Collective control (e) Location of Machine Room:Top of Building (As existing) (f)Machine : Gearless Machine(g) Travel :As per existing site to serve G+12 floor (h) Serving :G+ 12 upper floors- (13 Stops, 13 landings, 13 openings) (j)Existing Well size:As existing at site (as per Appx `A attached) 196 (k) Existing Pit depth : 1600 mm . (Existing Pit Depth is meeting the requirements of NBC , IS Codes and West Bengal Lift Rules. However if any modification is still required as per manufacturers recommendation the same shall be carriried out by Contractor without any extra cost to the Department) . Pit depth and overhead shall be such as to conform to the requirements of bottom clearance and top clearance as specified in IS: 14665. 197 (l) Head Room : As per existing site. (m) Power supply :415 volts Three-Phase, 50 Cycles AC. The entire lift equipment shall be suitable for operation at +10% to - 20% of rated supply voltage. (n) Auxiliary supply : 220 volts Single-Phase, 50 Cycles AC. (o) Earth connection : All new Earthing Points and Earth Contunity strips, connections Conductors shall be provided as per NBC, National Electrical Code and Code of Practices for Earhing. The cost of earthing and connected items shall be paid separaty under respective item of work in schedule.(p)Car Enclosure :Stainless Steel (Hairline) mirror finish body of car having minimum thickness of SS Sheet as 1.5 mm incl recessed LED light, false ceiling, as per NBC or other relevant BIS code.(q)Car Size : As per NBC 2016 or other relevant BIS code of latest edition..(r) Flooring:18-20mm thick granite flooring. (s) No of Entrance :One location - Front. 198 (t) Car Entrance : Automatic power operated centre opening, Stainless Steel, mirror finishDoor.(u) Landing Entrance : Automatic power operated centre opening, Stainless Steel, mirror finishDoor.(v) Clear opening for door : As per existing site.(w) Floor Designation : 0,1,2,3,4,5,6,7,8,9,10,11,12(x)Indicators : Car & Landings: Direction & Position Indicator/ call registration LEDs(y)Roping : Lift rope shall be provided as perNBC-2016 andIS 14665 - 2001 (upto date) of tensile strength not less than 12.5 tonnes/cm square andfactor of safety shall be 8.6(z) Battery operated emergency Alarm & Light shall be provided. (aa) Full height Infra-red Light Curtain Door Safety shall be provided.(ab) Press & Speak Phone shall be provided for intercom system. (ac) Fireman switch shall be provided. (ad)Emergency Automatic Rescue Device (ARD) with suitable capacity maintenance free battery shall be providedfor elevation of passengers trapped in lift car during power failure between floors .The ARD shall work for 3 phase and single phase failure. 199 (ae) Overload Protection Device, Load Weighing Device(LWD)/OSG (overspeed governors) Electronic switch shall be provided.(af)Voice announcement system in the car shall be provided to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator. (ag)Micro- Stroke illuminated push buttons shall be provided.(ah) All landing door shall be one hour fire rated.(aj) Car door lock shall be provided.(ak) Auto drive recall, Automatic Fan & light switching off arrangements shall be provided.(al) Hand Rails : Stainless steel mirror finish handrails on rear sides in car panels. Full height and full width mirror finishedstainless steel (1.5mm) panel to be provided on all side above hand rails.(am) MS Pit Ladder shall be provided.(an) Door Operator : DC Door Operator (ao) Car operating panel : Square flush painted illuminated buttons in Stainless steel (Hairline).(ap) Car position indicator : Dot matrix (Red LED) scrolling display. (aq) Hall fixtures : 16 segment display hall button. 200 (ar) Hall fixtures face plate : Stainless steel (Hairline).(as) Hall button arrangement :Hall button with FPI.(at) Standard Features : Anti nuisance car cell protection, overload device, nudging, independent service belt inspection device. Emergency Firemans service. Emergency car light unit,Infrared curtain protection, door time protection, emergency alarm button, extra door time of lobby and parking, door open/close button, manual rescue operation, belt inspection drive and auto fan cut off.ON/OFF system to be synchronised withcar door opening/closing system.(au) Machine room ladder , where applicable should be provided by the contractor (av) Hoist way wiring, where requiredshall be provided by the contractor(av) Ventilation : High powered axial flow fan with suitable air throw of 600 CFM through a duct all around the car so that uniform air flow shall be available at all side of the car. 201 Design supply , install, testing & commissioning of Passengers lift electrically operated, microprocessor controlled, speed 1.5 meter/sec, lift withsingle speed motor 415 volts, 3 phase, AC 50Hz supply conforming to IS-14665, suitable to serve G+12 upper floors with ACVariable Voltage Variable Frequency (VVVF) Regenerative (Cosed loop) drive ( ACD3-MR drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendent, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, emergency automatic rescue device (ARD) system with standby power supply by using suitable capacity maintenance free battery, 3D infra red sensor in full height of door & built in voice announcement system in the carto announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator, announcing system without hand set ( 03 Nos, one each in car, Machine room & near ground floor landing door),Battery operated emergency light & alarm complete all as specified for 10 passenger as per the details given belowcomplete all as specified and directed:-(Location of lift :TV 16) 202 (a) Type & capacity: 10 Passenger, 680 Kgs - Gearless (b) Speed:1.5 M/Sec (c) Type of Drive:VVVF Regenerative (Closed Loop)(d) Type of control :Microprocessor based Simplex full Collective control (e) Location of Machine Room:Top of Building (As existing) (f)Machine : Gearless Machine(g) Travel :As per existing site to serve G+12 floor (h) Serving :G+ 12 upper floors- (13 Stops, 13 landings, 13 openings) (j)Existing Well size:As existing at site (as per Appx `A attached) 203 (k) Existing Pit depth : 1600 mm . (Existing Pit Depth is meeting the requirements of NBC , IS Codes and West Bengal Lift Rules. However if any modification is still required as per manufacturers recommendation the same shall be carriried out by Contractor without any extra cost to the Department) . Pit depth and overhead shall be such as to conform to the requirements of bottom clearance and top clearance as specified in IS: 14665. 204 (l) Head Room : As per existing site. (m) Power supply :415 volts Three-Phase, 50 Cycles AC. The entire lift equipment shall be suitable for operation at +10% to - 20% of rated supply voltage. (n) Auxiliary supply : 220 volts Single-Phase, 50 Cycles AC. (o) Earth connection : All new Earthing Points and Earth Contunity strips, connections Conductors shall be provided as per NBC, National Electrical Code and Code of Practices for Earhing. The cost of earthing and connected items shall be paid separaty under respective item of work in schedule.(p)Car Enclosure :Stainless Steel (Hairline) mirror finish body of car having minimum thickness of SS Sheet as 1.5 mm incl recessed LED light, false ceiling, as per NBC or other relevant BIS code.(q)Car Size : As per NBC 2016 or other relevant BIS code of latest edition..(r) Flooring:18-20mm thick granite flooring. (s) No of Entrance :One location - Front. 205 (t) Car Entrance : Automatic power operated centre opening, Stainless Steel, mirror finishDoor.(u) Landing Entrance : Automatic power operated centre opening, Stainless Steel, mirror finishDoor.(v) Clear opening for door : As per existing site.(w) Floor Designation : 0,1,2,3,4,5,6,7,8,9,10,11,12(x)Indicators : Car & Landings: Direction & Position Indicator/ call registration LEDs(y)Roping : Lift rope shall be provided as perNBC-2016 andIS 14665 - 2001 (upto date) of tensile strength not less than 12.5 tonnes/cm square andfactor of safety shall be 8.6(z) Battery operated emergency Alarm & Light shall be provided. (aa) Full height Infra-red Light Curtain Door Safety shall be provided.(ab) Press & Speak Phone shall be provided for intercom system. (ac) Fireman switch shall be provided. (ad)Emergency Automatic Rescue Device (ARD) with suitable capacity maintenance free battery shall be providedfor elevation of passengers trapped in lift car during power failure between floors .The ARD shall work for 3 phase and single phase failure. 206 (ae) Overload Protection Device, Load Weighing Device(LWD)/OSG (overspeed governors) Electronic switch shall be provided.(af)Voice announcement system in the car shall be provided to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator. (ag)Micro- Stroke illuminated push buttons shall be provided.(ah) All landing door shall be one hour fire rated.(aj) Car door lock shall be provided.(ak) Auto drive recall, Automatic Fan & light switching off arrangements shall be provided.(al) Hand Rails : Stainless steel mirror finish handrails on rear sides in car panels. Full height and full width mirror finishedstainless steel (1.5mm) panel to be provided on all side above hand rails.(am) MS Pit Ladder shall be provided.(an) Door Operator : DC Door Operator (ao) Car operating panel : Square flush painted illuminated buttons in Stainless steel (Hairline).(ap) Car position indicator : Dot matrix (Red LED) scrolling display. (aq) Hall fixtures : 16 segment display hall button. 207 (ar) Hall fixtures face plate : Stainless steel (Hairline).(as) Hall button arrangement :Hall button with FPI.(at) Standard Features : Anti nuisance car cell protection, overload device, nudging, independent service belt inspection device. Emergency Firemans service. Emergency car light unit,Infrared curtain protection, door time protection, emergency alarm button, extra door time of lobby and parking, door open/close button, manual rescue operation, belt inspection drive and auto fan cut off.ON/OFF system to be synchronised withcar door opening/closing system.(au) Machine room ladder , where applicable should be provided by the contractor (av) Hoist way wiring, where requiredshall be provided by the contractor(av) Ventilation : High powered axial flow fan with suitable air throw of 600 CFM through a duct all around the car so that uniform air flow shall be available at all side of the car. 208 Design supply , install, testing & commissioning of Passengers lift electrically operated, microprocessor controlled, speed 1.5 meter/sec, lift withsingle speed motor 415 volts, 3 phase, AC 50Hz supply conforming to IS-14665, suitable to serve G+10 upper floors with ACVariable Voltage Variable Frequency (VVVF) Regenerative (Cosed loop) drive ( ACD3-MR drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendent, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, emergency automatic rescue device (ARD) system with standby power supply by using suitable capacity maintenance free battery, 3D infra red sensor in full height of door & built in voice announcement system in the carto announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator, announcing system without hand set ( 03 Nos, one each in car, Machine room & near ground floor landing door),Battery operated emergency light & alarm complete all as specified for 13 passenger as per the details given belowcomplete all as specified and directed:-(Location of lift :P197-1BMC, P198-1 BMC) 209 (a) Type & capacity: 13 Passenger, 884 Kgs - Gearless (b) Speed:1.5 M/Sec (c) Type of Drive:VVVF Regenerative (Closed Loop)(d) Type of control :Microprocessor based Simplex full Collective control (e) Location of Machine Room:Top of Building (As existing) (f)Machine : Gearless Machine(g) Travel :As per existing site to serve G+10 floor (h) Serving :G+ 10 upper floors- (11 Stops, 11 landings, 11 openings) (j)Existing Well size:As existing at site (as per Appx `A attached) 210 (k) Existing Pit depth : 1600 mm . (Existing Pit Depth is meeting the requirements of NBC , IS Codes and West Bengal Lift Rules. However if any modification is still required as per manufacturers recommendation the same shall be carriried out by Contractor without any extra cost to the Department) . Pit depth and overhead shall be such as to conform to the requirements of bottom clearance and top clearance as specified in IS: 14665. 211 (l) Head Room : As per existing site. (m) Power supply :415 volts Three-Phase, 50 Cycles AC. The entire lift equipment shall be suitable for operation at +10% to - 20% of rated supply voltage. (n) Auxiliary supply : 220 volts Single-Phase, 50 Cycles AC. (o) Earth connection : All new Earthing Points and Earth Contunity strips, connections Conductors shall be provided as per NBC, National Electrical Code and Code of Practices for Earhing. The cost of earthing and connected items shall be paid separaty under respective item of work in schedule.(p)Car Enclosure :Stainless Steel (Hairline) mirror finish body of car having minimum thickness of SS Sheet as 1.5 mm incl recessed LED light, false ceiling, as per NBC or other relevant BIS code.(q)Car Size : As per NBC 2016 or other relevant BIS code of latest edition..(r) Flooring:18-20mm thick granite flooring. (s) No of Entrance :One location - Front. 212 (t) Car Entrance : Automatic power operated centre opening, Stainless Steel, mirror finishDoor.(u) Landing Entrance : Automatic power operated centre opening, Stainless Steel, mirror finishDoor.(v) Clear opening for door : As per existing site.(w) Floor Designation : 0,1,2,3,4,5,6,7,8,9,10(x)Indicators : Car & Landings: Direction & Position Indicator/ call registration LEDs(y)Roping : Lift rope shall be provided as perNBC-2016 andIS 14665 - 2001 (upto date) of tensile strength not less than 12.5 tonnes/cm square andfactor of safety shall be 8.6(z) Battery operated emergency Alarm & Light shall be provided. (aa) Full height Infra-red Light Curtain Door Safety shall be provided.(ab) Press & Speak Phone shall be provided for intercom system. (ac) Fireman switch shall be provided. (ad)Emergency Automatic Rescue Device (ARD) with suitable capacity maintenance free battery shall be providedfor elevation of passengers trapped in lift car during power failure between floors .The ARD shall work for 3 phase and single phase failure. 213 (ae) Overload Protection Device, Load Weighing Device(LWD)/OSG (overspeed governors) Electronic switch shall be provided.(af)Voice announcement system in the car shall be provided to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator. (ag)Micro- Stroke illuminated push buttons shall be provided.(ah) All landing door shall be one hour fire rated.(aj) Car door lock shall be provided.(ak) Auto drive recall, Automatic Fan & light switching off arrangements shall be provided.(al) Hand Rails : Stainless steel mirror finish handrails on rear sides in car panels. Full height and full width mirror finishedstainless steel (1.5mm) panel to be provided on all side above hand rails.(am) MS Pit Ladder shall be provided.(an) Door Operator : DC Door Operator (ao) Car operating panel : Square flush painted illuminated buttons in Stainless steel (Hairline).(ap) Car position indicator : Dot matrix (Red LED) scrolling display. (aq) Hall fixtures : 16 segment display hall button. 214 (ar) Hall fixtures face plate : Stainless steel (Hairline).(as) Hall button arrangement :Hall button with FPI.(at) Standard Features : Anti nuisance car cell protection, overload device, nudging, independent service belt inspection device. Emergency Firemans service. Emergency car light unit,Infrared curtain protection, door time protection, emergency alarm button, extra door time of lobby and parking, door open/close button, manual rescue operation, belt inspection drive and auto fan cut off.ON/OFF system to be synchronised withcar door opening/closing system.(au) Machine room ladder , where applicable should be provided by the contractor (av) Hoist way wiring, where requiredshall be provided by the contractor(av) Ventilation : High powered axial flow fan with suitable air throw of 600 CFM through a duct all around the car so that uniform air flow shall be available at all side of the car. 215 Design supply , install, testing & commissioning of Passengers lift electrically operated, microprocessor controlled, speed 1.5 meter/sec, lift withsingle speed motor 415 volts, 3 phase, AC 50Hz supply conforming to IS-14665, suitable to serve G+10 upper floors with ACVariable Voltage Variable Frequency (VVVF) Regenerative (Cosed loop) drive ( ACD3-MR drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendent, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, emergency automatic rescue device (ARD) system with standby power supply by using suitable capacity maintenance free battery, 3D infra red sensor in full height of door & built in voice announcement system in the carto announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator, announcing system without hand set ( 03 Nos, one each in car, Machine room & near ground floor landing door),Battery operated emergency light & alarm complete all as specified for 8 passenger as per the details given belowcomplete all as specified and directed:-(Location of lift :P197-2 BMC, P198-2 BMC, MAP A-1 VD, MAP B-1 VD) 216 (a) Type & capacity: 8 Passenger, 544 Kgs - Gearless (b) Speed:1.5 M/Sec (c) Type of Drive:VVVF Regenerative (Closed Loop)(d) Type of control :Microprocessor based Simplex full Collective control (e) Location of Machine Room:Top of Building (As existing) (f)Machine : Gearless Machine(g) Travel :As per existing site to serve G+10 floor (h) Serving :G+ 10 upper floors- (11 Stops, 11 landings, 11 openings) (j)Existing Well size:As existing at site (as per Appx `A attached) 217 (k) Existing Pit depth : 1600 mm . (Existing Pit Depth is meeting the requirements of NBC , IS Codes and West Bengal Lift Rules. However if any modification is still required as per manufacturers recommendation the same shall be carriried out by Contractor without any extra cost to the Department) . Pit depth and overhead shall be such as to conform to the requirements of bottom clearance and top clearance as specified in IS: 14665. 218 (l) Head Room : As per existing site. (m) Power supply :415 volts Three-Phase, 50 Cycles AC. The entire lift equipment shall be suitable for operation at +10% to - 20% of rated supply voltage. (n) Auxiliary supply : 220 volts Single-Phase, 50 Cycles AC. (o) Earth connection : All new Earthing Points and Earth Contunity strips, connections Conductors shall be provided as per NBC, National Electrical Code and Code of Practices for Earhing. The cost of earthing and connected items shall be paid separaty under respective item of work in schedule.(p)Car Enclosure :Stainless Steel (Hairline) mirror finish body of car having minimum thickness of SS Sheet as 1.5 mm incl recessed LED light, false ceiling, as per NBC or other relevant BIS code.(q)Car Size : As per NBC 2016 or other relevant BIS code of latest edition..(r) Flooring:18-20mm thick granite flooring. (s) No of Entrance :One location - Front. 219 (t) Car Entrance : Automatic power operated centre opening, Stainless Steel, mirror finishDoor.(u) Landing Entrance : Automatic power operated centre opening, Stainless Steel, mirror finishDoor.(v) Clear opening for door : As per existing site.(w) Floor Designation : 0,1,2,3,4,5,6,7,8,9,10(x)Indicators : Car & Landings: Direction & Position Indicator/ call registration LEDs(y)Roping : Lift rope shall be provided as perNBC-2016 andIS 14665 - 2001 (upto date) of tensile strength not less than 12.5 tonnes/cm square andfactor of safety shall be 8.6(z) Battery operated emergency Alarm & Light shall be provided. (aa) Full height Infra-red Light Curtain Door Safety shall be provided.(ab) Press & Speak Phone shall be provided for intercom system. (ac) Fireman switch shall be provided. (ad)Emergency Automatic Rescue Device (ARD) with suitable capacity maintenance free battery shall be providedfor elevation of passengers trapped in lift car during power failure between floors .The ARD shall work for 3 phase and single phase failure. 220 (ae) Overload Protection Device, Load Weighing Device(LWD)/OSG (overspeed governors) Electronic switch shall be provided.(af)Voice announcement system in the car shall be provided to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator. (ag)Micro- Stroke illuminated push buttons shall be provided.(ah) All landing door shall be one hour fire rated.(aj) Car door lock shall be provided.(ak) Auto drive recall, Automatic Fan & light switching off arrangements shall be provided.(al) Hand Rails : Stainless steel mirror finish handrails on rear sides in car panels. Full height and full width mirror finishedstainless steel (1.5mm) panel to be provided on all side above hand rails.(am) MS Pit Ladder shall be provided.(an) Door Operator : DC Door Operator (ao) Car operating panel : Square flush painted illuminated buttons in Stainless steel (Hairline).(ap) Car position indicator : Dot matrix (Red LED) scrolling display. (aq) Hall fixtures : 16 segment display hall button. 221 (ar) Hall fixtures face plate : Stainless steel (Hairline).(as) Hall button arrangement :Hall button with FPI.(at) Standard Features : Anti nuisance car cell protection, overload device, nudging, independent service belt inspection device. Emergency Firemans service. Emergency car light unit,Infrared curtain protection, door time protection, emergency alarm button, extra door time of lobby and parking, door open/close button, manual rescue operation, belt inspection drive and auto fan cut off.ON/OFF system to be synchronised withcar door opening/closing system.(au) Machine room ladder , where applicable should be provided by the contractor (av) Hoist way wiring, where requiredshall be provided by the contractor(av) Ventilation : High powered axial flow fan with suitable air throw of 600 CFM through a duct all around the car so that uniform air flow shall be available at all side of the car. 222 Design supply , install, testing & commissioning of Passengers lift electrically operated, microprocessor controlled, speed 1.5 meter/sec, lift withsingle speed motor 415 volts, 3 phase, AC 50Hz supply conforming to IS-14665, suitable to serve G+10 upper floors with ACVariable Voltage Variable Frequency (VVVF) Regenerative (Cosed loop) drive ( ACD3-MR drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendent, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, emergency automatic rescue device (ARD) system with standby power supply by using suitable capacity maintenance free battery, 3D infra red sensor in full height of door & built in voice announcement system in the carto announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator, announcing system without hand set ( 03 Nos, one each in car, Machine room & near ground floor landing door),Battery operated emergency light & alarm complete all as specified for 6 passenger as per the details given belowcomplete all as specified and directed:-(Location of lift :TV18 ALIPORE) 223 (a) Type & capacity: 6 Passenger, 408 Kgs - Gearless (b) Speed:1.5 M/Sec (c) Type of Drive:VVVF Regenerative (Closed Loop)(d) Type of control :Microprocessor based Simplex full Collective control (e) Location of Machine Room:Top of Building (As existing) (f)Machine : Gearless Machine(g) Travel :As per existing site to serve G+10 floor (h) Serving :G+ 10 upper floors- (11 Stops, 11 landings, 11 openings) (j)Existing Well size:As existing at site (as per Appx `A attached) 224 (k) Existing Pit depth : 1600 mm . (Existing Pit Depth is meeting the requirements of NBC , IS Codes and West Bengal Lift Rules. However if any modification is still required as per manufacturers recommendation the same shall be carriried out by Contractor without any extra cost to the Department) . Pit depth and overhead shall be such as to conform to the requirements of bottom clearance and top clearance as specified in IS: 14665. 225 (l) Head Room : As per existing site. (m) Power supply :415 volts Three-Phase, 50 Cycles AC. The entire lift equipment shall be suitable for operation at +10% to - 20% of rated supply voltage. (n) Auxiliary supply : 220 volts Single-Phase, 50 Cycles AC. (o) Earth connection : All new Earthing Points and Earth Contunity strips, connections Conductors shall be provided as per NBC, National Electrical Code and Code of Practices for Earhing. The cost of earthing and connected items shall be paid separaty under respective item of work in schedule.(p)Car Enclosure :Stainless Steel (Hairline) mirror finish body of car having minimum thickness of SS Sheet as 1.5 mm incl recessed LED light, false ceiling, as per NBC or other relevant BIS code.(q)Car Size : As per NBC 2016 or other relevant BIS code of latest edition..(r) Flooring:18-20mm thick granite flooring. (s) No of Entrance :One location - Front. 226 (t) Car Entrance : Automatic power operated centre opening, Stainless Steel, mirror finishDoor.(u) Landing Entrance : Automatic power operated centre opening, Stainless Steel, mirror finishDoor.(v) Clear opening for door : As per existing site.(w) Floor Designation : 0,1,2,3,4,5,6,7,8,9,10(x)Indicators : Car & Landings: Direction & Position Indicator/ call registration LEDs(y)Roping : Lift rope shall be provided as perNBC-2016 andIS 14665 - 2001 (upto date) of tensile strength not less than 12.5 tonnes/cm square andfactor of safety shall be 8.6(z) Battery operated emergency Alarm & Light shall be provided. (aa) Full height Infra-red Light Curtain Door Safety shall be provided.(ab) Press & Speak Phone shall be provided for intercom system. (ac) Fireman switch shall be provided. (ad)Emergency Automatic Rescue Device (ARD) with suitable capacity maintenance free battery shall be providedfor elevation of passengers trapped in lift car during power failure between floors .The ARD shall work for 3 phase and single phase failure. 227 (ae) Overload Protection Device, Load Weighing Device(LWD)/OSG (overspeed governors) Electronic switch shall be provided.(af)Voice announcement system in the car shall be provided to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator. (ag)Micro- Stroke illuminated push buttons shall be provided.(ah) All landing door shall be one hour fire rated.(aj) Car door lock shall be provided.(ak) Auto drive recall, Automatic Fan & light switching off arrangements shall be provided.(al) Hand Rails : Stainless steel mirror finish handrails on rear sides in car panels. Full height and full width mirror finishedstainless steel (1.5mm) panel to be provided on all side above hand rails.(am) MS Pit Ladder shall be provided.(an) Door Operator : DC Door Operator (ao) Car operating panel : Square flush painted illuminated buttons in Stainless steel (Hairline).(ap) Car position indicator : Dot matrix (Red LED) scrolling display. (aq) Hall fixtures : 16 segment display hall button. 228 (ar) Hall fixtures face plate : Stainless steel (Hairline).(as) Hall button arrangement :Hall button with FPI.(at) Standard Features : Anti nuisance car cell protection, overload device, nudging, independent service belt inspection device. Emergency Firemans service. Emergency car light unit,Infrared curtain protection, door time protection, emergency alarm button, extra door time of lobby and parking, door open/close button, manual rescue operation, belt inspection drive and auto fan cut off.ON/OFF system to be synchronised withcar door opening/closing system.(au) Machine room ladder , where applicable should be provided by the contractor (av) Hoist way wiring, where requiredshall be provided by the contractor(av) Ventilation : High powered axial flow fan with suitable air throw of 600 CFM through a duct all around the car so that uniform air flow shall be available at all side of the car. 229 Design supply , install, testing & commissioning of Passengers lift electrically operated, microprocessor controlled, speed 1.5 meter/sec, lift withsingle speed motor 415 volts, 3 phase, AC 50Hz supply conforming to IS-14665, suitable to serve G+9 upper floors with ACVariable Voltage Variable Frequency (VVVF) Regenerative (Cosed loop) drive ( ACD3-MR drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendent, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, emergency automatic rescue device (ARD) system with standby power supply by using suitable capacity maintenance free battery, 3D infra red sensor in full height of door & built in voice announcement system in the carto announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator, announcing system without hand set ( 03 Nos, one each in car, Machine room & near ground floor landing door),Battery operated emergency light & alarm complete all as specified for 8 passenger as per the details given belowcomplete all as specified and directed:-(Location of lift :JSA ENCLAVE BLOCK1 AND BLOCK 2- 02 NOS) 230 (a) Type & capacity: 8 Passenger, 544 Kgs - Gearless (b) Speed:1.5 M/Sec (c) Type of Drive:VVVF Regenerative (Closed Loop)(d) Type of control :Microprocessor based Simplex full Collective control (e) Location of Machine Room:Top of Building (As existing) (f)Machine : Gearless Machine(g) Travel :As per existing site to serve G+9 floor (h) Serving :G+ 9 upper floors- (10 Stops, 10 landings, 10 openings) (j)Existing Well size:As existing at site (as per Appx `A attached) 231 (k) Existing Pit depth : 1600 mm . (Existing Pit Depth is meeting the requirements of NBC , IS Codes and West Bengal Lift Rules. However if any modification is still required as per manufacturers recommendation the same shall be carriried out by Contractor without any extra cost to the Department) . Pit depth and overhead shall be such as to conform to the requirements of bottom clearance and top clearance as specified in IS: 14665. 232 (l) Head Room : As per existing site. (m) Power supply :415 volts Three-Phase, 50 Cycles AC. The entire lift equipment shall be suitable for operation at +10% to - 20% of rated supply voltage. (n) Auxiliary supply : 220 volts Single-Phase, 50 Cycles AC. (o) Earth connection : All new Earthing Points and Earth Contunity strips, connections Conductors shall be provided as per NBC, National Electrical Code and Code of Practices for Earhing. The cost of earthing and connected items shall be paid separaty under respective item of work in schedule.(p)Car Enclosure :Stainless Steel (Hairline) mirror finish body of car having minimum thickness of SS Sheet as 1.5 mm incl recessed LED light, false ceiling, as per NBC or other relevant BIS code.(q)Car Size : As per NBC 2016 or other relevant BIS code of latest edition..(r) Flooring:18-20mm thick granite flooring. (s) No of Entrance :One location - Front. 233 (t) Car Entrance : Automatic power operated centre opening, Stainless Steel, mirror finishDoor.(u) Landing Entrance : Automatic power operated centre opening, Stainless Steel, mirror finishDoor.(v) Clear opening for door : As per existing site.(w) Floor Designation : 0,1,2,3,4,5,6,7,8,9(x)Indicators : Car & Landings: Direction & Position Indicator/ call registration LEDs(y)Roping : Lift rope shall be provided as perNBC-2016 andIS 14665 - 2001 (upto date) of tensile strength not less than 12.5 tonnes/cm square andfactor of safety shall be 8.6(z) Battery operated emergency Alarm & Light shall be provided. (aa) Full height Infra-red Light Curtain Door Safety shall be provided.(ab) Press & Speak Phone shall be provided for intercom system. (ac) Fireman switch shall be provided. (ad)Emergency Automatic Rescue Device (ARD) with suitable capacity maintenance free battery shall be providedfor elevation of passengers trapped in lift car during power failure between floors .The ARD shall work for 3 phase and single phase failure. 234 (ae) Overload Protection Device, Load Weighing Device(LWD)/OSG (overspeed governors) Electronic switch shall be provided.(af)Voice announcement system in the car shall be provided to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator. (ag)Micro- Stroke illuminated push buttons shall be provided.(ah) All landing door shall be one hour fire rated.(aj) Car door lock shall be provided.(ak) Auto drive recall, Automatic Fan & light switching off arrangements shall be provided.(al) Hand Rails : Stainless steel mirror finish handrails on rear sides in car panels. Full height and full width mirror finishedstainless steel (1.5mm) panel to be provided on all side above hand rails.(am) MS Pit Ladder shall be provided.(an) Door Operator : DC Door Operator (ao) Car operating panel : Square flush painted illuminated buttons in Stainless steel (Hairline).(ap) Car position indicator : Dot matrix (Red LED) scrolling display. (aq) Hall fixtures : 16 segment display hall button. 235 (ar) Hall fixtures face plate : Stainless steel (Hairline).(as) Hall button arrangement :Hall button with FPI.(at) Standard Features : Anti nuisance car cell protection, overload device, nudging, independent service belt inspection device. Emergency Firemans service. Emergency car light unit,Infrared curtain protection, door time protection, emergency alarm button, extra door time of lobby and parking, door open/close button, manual rescue operation, belt inspection drive and auto fan cut off.ON/OFF system to be synchronised withcar door opening/closing system.(au) Machine room ladder , where applicable should be provided by the contractor (av) Hoist way wiring, where requiredshall be provided by the contractor(av) Ventilation : High powered axial flow fan with suitable air throw of 600 CFM through a duct all around the car so that uniform air flow shall be available at all side of the car. 236 Design supply , install, testing & commissioning of Passengers lift electrically operated, microprocessor controlled, speed 1.5 meter/sec, lift withsingle speed motor 415 volts, 3 phase, AC 50Hz supply conforming to IS-14665, suitable to serve G+7 upper floors with ACVariable Voltage Variable Frequency (VVVF) Regenerative (Cosed loop) drive ( ACD3-MR drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendent, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, emergency automatic rescue device (ARD) system with standby power supply by using suitable capacity maintenance free battery, 3D infra red sensor in full height of door & built in voice announcement system in the carto announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator, announcing system without hand set ( 03 Nos, one each in car, Machine room & near ground floor landing door),Battery operated emergency light & alarm complete all as specified for 8 passenger as per the details given belowcomplete all as specified and directed:-(Location of lift :P173 BMC-01) 237 (a) Type & capacity: 8 Passenger, 544 Kgs - Gearless (b) Speed:1.5 M/Sec (c) Type of Drive:VVVF Regenerative (Closed Loop)(d) Type of control :Microprocessor based Simplex full Collective control (e) Location of Machine Room:Top of Building (As existing) (f)Machine : Gearless Machine(g) Travel :As per existing site to serve G+7 floor (h) Serving :G+ 7 upper floors- (8 Stops, 8 landings, 8 openings) (j)Existing Well size:As existing at site (as per Appx `A attached) 238 (k) Existing Pit depth : 1600 mm . (Existing Pit Depth is meeting the requirements of NBC , IS Codes and West Bengal Lift Rules. However if any modification is still required as per manufacturers recommendation the same shall be carriried out by Contractor without any extra cost to the Department) . Pit depth and overhead shall be such as to conform to the requirements of bottom clearance and top clearance as specified in IS: 14665. 239 (l) Head Room : As per existing site. (m) Power supply :415 volts Three-Phase, 50 Cycles AC. The entire lift equipment shall be suitable for operation at +10% to - 20% of rated supply voltage. (n) Auxiliary supply : 220 volts Single-Phase, 50 Cycles AC. (o) Earth connection : All new Earthing Points and Earth Contunity strips, connections Conductors shall be provided as per NBC, National Electrical Code and Code of Practices for Earhing. The cost of earthing and connected items shall be paid separaty under respective item of work in schedule.(p)Car Enclosure :Stainless Steel (Hairline) mirror finish body of car having minimum thickness of SS Sheet as 1.5 mm incl recessed LED light, false ceiling, as per NBC or other relevant BIS code.(q)Car Size : As per NBC 2016 or other relevant BIS code of latest edition..(r) Flooring:18-20mm thick granite flooring. (s) No of Entrance :One location - Front. 240 (t) Car Entrance : Automatic power operated centre opening, Stainless Steel, mirror finishDoor.(u) Landing Entrance : Automatic power operated centre opening, Stainless Steel, mirror finishDoor.(v) Clear opening for door : As per existing site.(w) Floor Designation : 0,1,2,3,4,5,6,7(x)Indicators : Car & Landings: Direction & Position Indicator/ call registration LEDs(y)Roping : Lift rope shall be provided as perNBC-2016 andIS 14665 - 2001 (upto date) of tensile strength not less than 12.5 tonnes/cm square andfactor of safety shall be 8.6(z) Battery operated emergency Alarm & Light shall be provided. (aa) Full height Infra-red Light Curtain Door Safety shall be provided.(ab) Press & Speak Phone shall be provided for intercom system. (ac) Fireman switch shall be provided. (ad)Emergency Automatic Rescue Device (ARD) with suitable capacity maintenance free battery shall be providedfor elevation of passengers trapped in lift car during power failure between floors .The ARD shall work for 3 phase and single phase failure. 241 (ae) Overload Protection Device, Load Weighing Device(LWD)/OSG (overspeed governors) Electronic switch shall be provided.(af)Voice announcement system in the car shall be provided to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator. (ag)Micro- Stroke illuminated push buttons shall be provided.(ah) All landing door shall be one hour fire rated.(aj) Car door lock shall be provided.(ak) Auto drive recall, Automatic Fan & light switching off arrangements shall be provided.(al) Hand Rails : Stainless steel mirror finish handrails on rear sides in car panels. Full height and full width mirror finishedstainless steel (1.5mm) panel to be provided on all side above hand rails.(am) MS Pit Ladder shall be provided.(an) Door Operator : DC Door Operator (ao) Car operating panel : Square flush painted illuminated buttons in Stainless steel (Hairline).(ap) Car position indicator : Dot matrix (Red LED) scrolling display. (aq) Hall fixtures : 16 segment display hall button. 242 (ar) Hall fixtures face plate : Stainless steel (Hairline).(as) Hall button arrangement :Hall button with FPI.(at) Standard Features : Anti nuisance car cell protection, overload device, nudging, independent service belt inspection device. Emergency Firemans service. Emergency car light unit,Infrared curtain protection, door time protection, emergency alarm button, extra door time of lobby and parking, door open/close button, manual rescue operation, belt inspection drive and auto fan cut off.ON/OFF system to be synchronised withcar door opening/closing system.(au) Machine room ladder , where applicable should be provided by the contractor (av) Hoist way wiring, where requiredshall be provided by the contractor(av) Ventilation : High powered axial flow fan with suitable air throw of 600 CFM through a duct all around the car so that uniform air flow shall be available at all side of the car. 243 Design supply , install, testing & commissioning of Passengers lift electrically operated, microprocessor controlled, speed 1.5 meter/sec, lift withsingle speed motor 415 volts, 3 phase, AC 50Hz supply conforming to IS-14665, suitable to serve G+6 upper floors with ACVariable Voltage Variable Frequency (VVVF) Regenerative (Cosed loop) drive ( ACD3-MR drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendent, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, emergency automatic rescue device (ARD) system with standby power supply by using suitable capacity maintenance free battery, 3D infra red sensor in full height of door & built in voice announcement system in the carto announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator, announcing system without hand set ( 03 Nos, one each in car, Machine room & near ground floor landing door),Battery operated emergency light & alarm complete all as specified for 13 passenger as per the details given belowcomplete all as specified and directed:-(Location of lift :P127 BMC-01) 244 (a) Type & capacity: 13 Passenger, 884 Kgs - Gearless (b) Speed:1.5 M/Sec (c) Type of Drive:VVVF Regenerative (Closed Loop)(d) Type of control :Microprocessor based Simplex full Collective control (e) Location of Machine Room:Top of Building (As existing) (f)Machine : Gearless Machine(g) Travel :As per existing site to serve G+6 floor (h) Serving :G+ 6 upper floors- (7 Stops, 7 landings, 7 openings) (j)Existing Well size:As existing at site (as per Appx `A attached) 245 (k) Existing Pit depth : 1600 mm . (Existing Pit Depth is meeting the requirements of NBC , IS Codes and West Bengal Lift Rules. However if any modification is still required as per manufacturers recommendation the same shall be carriried out by Contractor without any extra cost to the Department) . Pit depth and overhead shall be such as to conform to the requirements of bottom clearance and top clearance as specified in IS: 14665. 246 (l) Head Room : As per existing site. (m) Power supply :415 volts Three-Phase, 50 Cycles AC. The entire lift equipment shall be suitable for operation at +10% to - 20% of rated supply voltage. (n) Auxiliary supply : 220 volts Single-Phase, 50 Cycles AC. (o) Earth connection : All new Earthing Points and Earth Contunity strips, connections Conductors shall be provided as per NBC, National Electrical Code and Code of Practices for Earhing. The cost of earthing and connected items shall be paid separaty under respective item of work in schedule.(p)Car Enclosure :Stainless Steel (Hairline) mirror finish body of car having minimum thickness of SS Sheet as 1.5 mm incl recessed LED light, false ceiling, as per NBC or other relevant BIS code.(q)Car Size : As per NBC 2016 or other relevant BIS code of latest edition..(r) Flooring:18-20mm thick granite flooring. (s) No of Entrance :One location - Front. 247 (t) Car Entrance : Automatic power operated centre opening, Stainless Steel, mirror finishDoor.(u) Landing Entrance : Automatic power operated centre opening, Stainless Steel, mirror finishDoor.(v) Clear opening for door : As per existing site.(w) Floor Designation : 0,1,2,3,4,5,6(x)Indicators : Car & Landings: Direction & Position Indicator/ call registration LEDs(y)Roping : Lift rope shall be provided as perNBC-2016 andIS 14665 - 2001 (upto date) of tensile strength not less than 12.5 tonnes/cm square andfactor of safety shall be 8.6(z) Battery operated emergency Alarm & Light shall be provided. (aa) Full height Infra-red Light Curtain Door Safety shall be provided.(ab) Press & Speak Phone shall be provided for intercom system. (ac) Fireman switch shall be provided. (ad)Emergency Automatic Rescue Device (ARD) with suitable capacity maintenance free battery shall be providedfor elevation of passengers trapped in lift car during power failure between floors .The ARD shall work for 3 phase and single phase failure. 248 (ae) Overload Protection Device, Load Weighing Device(LWD)/OSG (overspeed governors) Electronic switch shall be provided.(af)Voice announcement system in the car shall be provided to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator. (ag)Micro- Stroke illuminated push buttons shall be provided.(ah) All landing door shall be one hour fire rated.(aj) Car door lock shall be provided.(ak) Auto drive recall, Automatic Fan & light switching off arrangements shall be provided.(al) Hand Rails : Stainless steel mirror finish handrails on rear sides in car panels. Full height and full width mirror finishedstainless steel (1.5mm) panel to be provided on all side above hand rails.(am) MS Pit Ladder shall be provided.(an) Door Operator : DC Door Operator (ao) Car operating panel : Square flush painted illuminated buttons in Stainless steel (Hairline).(ap) Car position indicator : Dot matrix (Red LED) scrolling display. (aq) Hall fixtures : 16 segment display hall button. 249 (ar) Hall fixtures face plate : Stainless steel (Hairline).(as) Hall button arrangement :Hall button with FPI.(at) Standard Features : Anti nuisance car cell protection, overload device, nudging, independent service belt inspection device. Emergency Firemans service. Emergency car light unit,Infrared curtain protection, door time protection, emergency alarm button, extra door time of lobby and parking, door open/close button, manual rescue operation, belt inspection drive and auto fan cut off.ON/OFF system to be synchronised withcar door opening/closing system.(au) Machine room ladder , where applicable should be provided by the contractor (av) Hoist way wiring, where requiredshall be provided by the contractor(av) Ventilation : High powered axial flow fan with suitable air throw of 600 CFM through a duct all around the car so that uniform air flow shall be available at all side of the car. 250 Design supply , install, testing & commissioning of Passengers lift electrically operated, microprocessor controlled, speed 1.5 meter/sec, lift withsingle speed motor 415 volts, 3 phase, AC 50Hz supply conforming to IS-14665, suitable to serve G+6 upper floors with ACVariable Voltage Variable Frequency (VVVF) Regenerative (Cosed loop) drive ( ACD3-MR drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendent, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, emergency automatic rescue device (ARD) system with standby power supply by using suitable capacity maintenance free battery, 3D infra red sensor in full height of door & built in voice announcement system in the carto announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator, announcing system without hand set ( 03 Nos, one each in car, Machine room & near ground floor landing door),Battery operated emergency light & alarm complete all as specified for 8 passenger as per the details given belowcomplete all as specified and directed:-(Location of lift :MAPC VD-01, TV15 ALIPORE -01) 251 (a) Type & capacity: 8 Passenger, 544 Kgs - Gearless (b) Speed:1.5 M/Sec (c) Type of Drive:VVVF Regenerative (Closed Loop)(d) Type of control :Microprocessor based Simplex full Collective control (e) Location of Machine Room:Top of Building (As existing) (f)Machine : Gearless Machine(g) Travel :As per existing site to serve G+6 floor (h) Serving :G+ 6 upper floors- (7 Stops, 7 landings, 7 openings) (j)Existing Well size:As existing at site (as per Appx `A attached) 252 (k) Existing Pit depth : 1600 mm . (Existing Pit Depth is meeting the requirements of NBC , IS Codes and West Bengal Lift Rules. However if any modification is still required as per manufacturers recommendation the same shall be carriried out by Contractor without any extra cost to the Department) . Pit depth and overhead shall be such as to conform to the requirements of bottom clearance and top clearance as specified in IS: 14665. 253 (l) Head Room : As per existing site. (m) Power supply :415 volts Three-Phase, 50 Cycles AC. The entire lift equipment shall be suitable for operation at +10% to - 20% of rated supply voltage. (n) Auxiliary supply : 220 volts Single-Phase, 50 Cycles AC. (o) Earth connection : All new Earthing Points and Earth Contunity strips, connections Conductors shall be provided as per NBC, National Electrical Code and Code of Practices for Earhing. The cost of earthing and connected items shall be paid separaty under respective item of work in schedule.(p)Car Enclosure :Stainless Steel (Hairline) mirror finish body of car having minimum thickness of SS Sheet as 1.5 mm incl recessed LED light, false ceiling, as per NBC or other relevant BIS code.(q)Car Size : As per NBC 2016 or other relevant BIS code of latest edition..(r) Flooring:18-20mm thick granite flooring. (s) No of Entrance :One location - Front. 254 (t) Car Entrance : Automatic power operated centre opening, Stainless Steel, mirror finishDoor.(u) Landing Entrance : Automatic power operated centre opening, Stainless Steel, mirror finishDoor.(v) Clear opening for door : As per existing site.(w) Floor Designation : 0,1,2,3,4,5,6(x)Indicators : Car & Landings: Direction & Position Indicator/ call registration LEDs(y)Roping : Lift rope shall be provided as perNBC-2016 andIS 14665 - 2001 (upto date) of tensile strength not less than 12.5 tonnes/cm square andfactor of safety shall be 8.6(z) Battery operated emergency Alarm & Light shall be provided. (aa) Full height Infra-red Light Curtain Door Safety shall be provided.(ab) Press & Speak Phone shall be provided for intercom system. (ac) Fireman switch shall be provided. (ad)Emergency Automatic Rescue Device (ARD) with suitable capacity maintenance free battery shall be providedfor elevation of passengers trapped in lift car during power failure between floors .The ARD shall work for 3 phase and single phase failure. 255 (ae) Overload Protection Device, Load Weighing Device(LWD)/OSG (overspeed governors) Electronic switch shall be provided.(af)Voice announcement system in the car shall be provided to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator. (ag)Micro- Stroke illuminated push buttons shall be provided.(ah) All landing door shall be one hour fire rated.(aj) Car door lock shall be provided.(ak) Auto drive recall, Automatic Fan & light switching off arrangements shall be provided.(al) Hand Rails : Stainless steel mirror finish handrails on rear sides in car panels. Full height and full width mirror finishedstainless steel (1.5mm) panel to be provided on all side above hand rails.(am) MS Pit Ladder shall be provided.(an) Door Operator : DC Door Operator (ao) Car operating panel : Square flush painted illuminated buttons in Stainless steel (Hairline).(ap) Car position indicator : Dot matrix (Red LED) scrolling display. (aq) Hall fixtures : 16 segment display hall button. 256 (ar) Hall fixtures face plate : Stainless steel (Hairline).(as) Hall button arrangement :Hall button with FPI.(at) Standard Features : Anti nuisance car cell protection, overload device, nudging, independent service belt inspection device. Emergency Firemans service. Emergency car light unit,Infrared curtain protection, door time protection, emergency alarm button, extra door time of lobby and parking, door open/close button, manual rescue operation, belt inspection drive and auto fan cut off.ON/OFF system to be synchronised withcar door opening/closing system.(au) Machine room ladder , where applicable should be provided by the contractor (av) Hoist way wiring, where requiredshall be provided by the contractor(av) Ventilation : High powered axial flow fan with suitable air throw of 600 CFM through a duct all around the car so that uniform air flow shall be available at all side of the car. 257 Design supply , install, testing & commissioning of Passengers lift electrically operated, microprocessor controlled, speed 1.5 meter/sec, lift withsingle speed motor 415 volts, 3 phase, AC 50Hz supply conforming to IS-14665, suitable to serve G+5 upper floors with ACVariable Voltage Variable Frequency (VVVF) Regenerative (Cosed loop) drive ( ACD3-MR drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendent, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, emergency automatic rescue device (ARD) system with standby power supply by using suitable capacity maintenance free battery, 3D infra red sensor in full height of door & built in voice announcement system in the carto announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator, announcing system without hand set ( 03 Nos, one each in car, Machine room & near ground floor landing door),Battery operated emergency light & alarm complete all as specified for 8 passenger as per the details given belowcomplete all as specified and directed:-(Location of lift :P/1 VD-03 NOS) 258 (a) Type & capacity: 8 Passenger, 544 Kgs - Gearless (b) Speed:1.5 M/Sec (c) Type of Drive:VVVF Regenerative (Closed Loop)(d) Type of control :Microprocessor based Simplex full Collective control (e) Location of Machine Room:Top of Building (As existing) (f)Machine : Gearless Machine(g) Travel :As per existing site to serve G+5 floor (h) Serving :G+ 5 upper floors- (6 Stops, 6 landings, 6 openings) (j)Existing Well size:As existing at site (as per Appx `A attached) 259 (k) Existing Pit depth : 1600 mm . (Existing Pit Depth is meeting the requirements of NBC , IS Codes and West Bengal Lift Rules. However if any modification is still required as per manufacturers recommendation the same shall be carriried out by Contractor without any extra cost to the Department) . Pit depth and overhead shall be such as to conform to the requirements of bottom clearance and top clearance as specified in IS: 14665. 260 (l) Head Room : As per existing site. (m) Power supply :415 volts Three-Phase, 50 Cycles AC. The entire lift equipment shall be suitable for operation at +10% to - 20% of rated supply voltage. (n) Auxiliary supply : 220 volts Single-Phase, 50 Cycles AC. (o) Earth connection : All new Earthing Points and Earth Contunity strips, connections Conductors shall be provided as per NBC, National Electrical Code and Code of Practices for Earhing. The cost of earthing and connected items shall be paid separaty under respective item of work in schedule.(p)Car Enclosure :Stainless Steel (Hairline) mirror finish body of car having minimum thickness of SS Sheet as 1.5 mm incl recessed LED light, false ceiling, as per NBC or other relevant BIS code.(q)Car Size : As per NBC 2016 or other relevant BIS code of latest edition..(r) Flooring:18-20mm thick granite flooring. (s) No of Entrance :One location - Front. 261 (t) Car Entrance : Automatic power operated centre opening, Stainless Steel, mirror finishDoor.(u) Landing Entrance : Automatic power operated centre opening, Stainless Steel, mirror finishDoor.(v) Clear opening for door : As per existing site.(w) Floor Designation : 0,1,2,3,4,5(x)Indicators : Car & Landings: Direction & Position Indicator/ call registration LEDs(y)Roping : Lift rope shall be provided as perNBC-2016 andIS 14665 - 2001 (upto date) of tensile strength not less than 12.5 tonnes/cm square andfactor of safety shall be 8.6(z) Battery operated emergency Alarm & Light shall be provided. (aa) Full height Infra-red Light Curtain Door Safety shall be provided.(ab) Press & Speak Phone shall be provided for intercom system. (ac) Fireman switch shall be provided. (ad)Emergency Automatic Rescue Device (ARD) with suitable capacity maintenance free battery shall be providedfor elevation of passengers trapped in lift car during power failure between floors .The ARD shall work for 3 phase and single phase failure. 262 (ae) Overload Protection Device, Load Weighing Device(LWD)/OSG (overspeed governors) Electronic switch shall be provided.(af)Voice announcement system in the car shall be provided to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator. (ag)Micro- Stroke illuminated push buttons shall be provided.(ah) All landing door shall be one hour fire rated.(aj) Car door lock shall be provided.(ak) Auto drive recall, Automatic Fan & light switching off arrangements shall be provided.(al) Hand Rails : Stainless steel mirror finish handrails on rear sides in car panels. Full height and full width mirror finishedstainless steel (1.5mm) panel to be provided on all side above hand rails.(am) MS Pit Ladder shall be provided.(an) Door Operator : DC Door Operator (ao) Car operating panel : Square flush painted illuminated buttons in Stainless steel (Hairline).(ap) Car position indicator : Dot matrix (Red LED) scrolling display. (aq) Hall fixtures : 16 segment display hall button. 263 (ar) Hall fixtures face plate : Stainless steel (Hairline).(as) Hall button arrangement :Hall button with FPI.(at) Standard Features : Anti nuisance car cell protection, overload device, nudging, independent service belt inspection device. Emergency Firemans service. Emergency car light unit,Infrared curtain protection, door time protection, emergency alarm button, extra door time of lobby and parking, door open/close button, manual rescue operation, belt inspection drive and auto fan cut off.ON/OFF system to be synchronised withcar door opening/closing system.(au) Machine room ladder , where applicable should be provided by the contractor (av) Hoist way wiring, where requiredshall be provided by the contractor(av) Ventilation : High powered axial flow fan with suitable air throw of 600 CFM through a duct all around the car so that uniform air flow shall be available at all side of the car. 264 Design supply , install, testing & commissioning of Passengers lift electrically operated, microprocessor controlled, speed 1.5 meter/sec, lift withsingle speed motor 415 volts, 3 phase, AC 50Hz supply conforming to IS-14665, suitable to serve G+4 upper floors with ACVariable Voltage Variable Frequency (VVVF) Regenerative (Cosed loop) drive ( ACD3-MR drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendent, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, emergency automatic rescue device (ARD) system with standby power supply by using suitable capacity maintenance free battery, 3D infra red sensor in full height of door & built in voice announcement system in the carto announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator, announcing system without hand set ( 03 Nos, one each in car, Machine room & near ground floor landing door),Battery operated emergency light & alarm complete all as specified for 6 passenger as per the details given belowcomplete all as specified and directed:-(Location of lift :O32 IGS- 01) 265 (a) Type & capacity: 6 Passenger, 408 Kgs - Gearless (b) Speed:1.5 M/Sec (c) Type of Drive:VVVF Regenerative (Closed Loop)(d) Type of control :Microprocessor based Simplex full Collective control (e) Location of Machine Room:Top of Building (As existing) (f)Machine : Gearless Machine(g) Travel :As per existing site to serve G+4 floor (h) Serving :G+ 4 upper floors- (5 Stops, 5 landings, 5 openings) (j)Existing Well size:As existing at site (as per Appx `A attached) 266 (k) Existing Pit depth : 1600 mm . (Existing Pit Depth is meeting the requirements of NBC , IS Codes and West Bengal Lift Rules. However if any modification is still required as per manufacturers recommendation the same shall be carriried out by Contractor without any extra cost to the Department) . Pit depth and overhead shall be such as to conform to the requirements of bottom clearance and top clearance as specified in IS: 14665. 267 (l) Head Room : As per existing site. (m) Power supply :415 volts Three-Phase, 50 Cycles AC. The entire lift equipment shall be suitable for operation at +10% to - 20% of rated supply voltage. (n) Auxiliary supply : 220 volts Single-Phase, 50 Cycles AC. (o) Earth connection : All new Earthing Points and Earth Contunity strips, connections Conductors shall be provided as per NBC, National Electrical Code and Code of Practices for Earhing. The cost of earthing and connected items shall be paid separaty under respective item of work in schedule.(p)Car Enclosure :Stainless Steel (Hairline) mirror finish body of car having minimum thickness of SS Sheet as 1.5 mm incl recessed LED light, false ceiling, as per NBC or other relevant BIS code.(q)Car Size : As per NBC 2016 or other relevant BIS code of latest edition..(r) Flooring:18-20mm thick granite flooring. (s) No of Entrance :One location - Front. 268 (t) Car Entrance : Automatic power operated centre opening, Stainless Steel, mirror finishDoor.(u) Landing Entrance : Automatic power operated centre opening, Stainless Steel, mirror finishDoor.(v) Clear opening for door : As per existing site.(w) Floor Designation : 0,1,2,3,4(x)Indicators : Car & Landings: Direction & Position Indicator/ call registration LEDs(y)Roping : Lift rope shall be provided as perNBC-2016 andIS 14665 - 2001 (upto date) of tensile strength not less than 12.5 tonnes/cm square andfactor of safety shall be 8.6(z) Battery operated emergency Alarm & Light shall be provided. (aa) Full height Infra-red Light Curtain Door Safety shall be provided.(ab) Press & Speak Phone shall be provided for intercom system. (ac) Fireman switch shall be provided. (ad)Emergency Automatic Rescue Device (ARD) with suitable capacity maintenance free battery shall be providedfor elevation of passengers trapped in lift car during power failure between floors .The ARD shall work for 3 phase and single phase failure. 269 (ae) Overload Protection Device, Load Weighing Device(LWD)/OSG (overspeed governors) Electronic switch shall be provided.(af)Voice announcement system in the car shall be provided to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator. (ag)Micro- Stroke illuminated push buttons shall be provided.(ah) All landing door shall be one hour fire rated.(aj) Car door lock shall be provided.(ak) Auto drive recall, Automatic Fan & light switching off arrangements shall be provided.(al) Hand Rails : Stainless steel mirror finish handrails on rear sides in car panels. Full height and full width mirror finishedstainless steel (1.5mm) panel to be provided on all side above hand rails.(am) MS Pit Ladder shall be provided.(an) Door Operator : DC Door Operator (ao) Car operating panel : Square flush painted illuminated buttons in Stainless steel (Hairline).(ap) Car position indicator : Dot matrix (Red LED) scrolling display. (aq) Hall fixtures : 16 segment display hall button. 270 (ar) Hall fixtures face plate : Stainless steel (Hairline).(as) Hall button arrangement :Hall button with FPI.(at) Standard Features : Anti nuisance car cell protection, overload device, nudging, independent service belt inspection device. Emergency Firemans service. Emergency car light unit,Infrared curtain protection, door time protection, emergency alarm button, extra door time of lobby and parking, door open/close button, manual rescue operation, belt inspection drive and auto fan cut off.ON/OFF system to be synchronised withcar door opening/closing system.(au) Machine room ladder , where applicable should be provided by the contractor (av) Hoist way wiring, where requiredshall be provided by the contractor(av) Ventilation : High powered axial flow fan with suitable air throw of 600 CFM through a duct all around the car so that uniform air flow shall be available at all side of the car. 271 Design supply , install, testing & commissioning of Passengers lift electrically operated, microprocessor controlled, speed 1.5 meter/sec, lift withsingle speed motor 415 volts, 3 phase, AC 50Hz supply conforming to IS-14665, suitable to serve G+5 upper floors with ACVariable Voltage Variable Frequency (VVVF) Regenerative (Cosed loop) drive ( ACD3-MR drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendent, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, emergency automatic rescue device (ARD) system with standby power supply by using suitable capacity maintenance free battery, 3D infra red sensor in full height of door & built in voice announcement system in the carto announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator, announcing system without hand set ( 03 Nos, one each in car, Machine room & near ground floor landing door),Battery operated emergency light & alarm complete all as specified for 6 passenger as per the details given belowcomplete all as specified and directed:-(Location of lift :TV13 ALIPORE-01, TV14 ALIPORE-01) 272 (a) Type & capacity: 6 Passenger, 408 Kgs - Gearless (b) Speed:1.5 M/Sec (c) Type of Drive:VVVF Regenerative (Closed Loop)(d) Type of control :Microprocessor based Simplex full Collective control (e) Location of Machine Room:Top of Building (As existing) (f)Machine : Gearless Machine(g) Travel :As per existing site to serve G+5 floor (h) Serving :G+ 5 upper floors- (6 Stops, 6 landings, 6 openings) (j)Existing Well size:As existing at site (as per Appx `A attached) 273 (k) Existing Pit depth : 1600 mm . (Existing Pit Depth is meeting the requirements of NBC , IS Codes and West Bengal Lift Rules. However if any modification is still required as per manufacturers recommendation the same shall be carriried out by Contractor without any extra cost to the Department) . Pit depth and overhead shall be such as to conform to the requirements of bottom clearance and top clearance as specified in IS: 14665. 274 (l) Head Room : As per existing site. (m) Power supply :415 volts Three-Phase, 50 Cycles AC. The entire lift equipment shall be suitable for operation at +10% to - 20% of rated supply voltage. (n) Auxiliary supply : 220 volts Single-Phase, 50 Cycles AC. (o) Earth connection : All new Earthing Points and Earth Contunity strips, connections Conductors shall be provided as per NBC, National Electrical Code and Code of Practices for Earhing. The cost of earthing and connected items shall be paid separaty under respective item of work in schedule.(p)Car Enclosure :Stainless Steel (Hairline) mirror finish body of car having minimum thickness of SS Sheet as 1.5 mm incl recessed LED light, false ceiling, as per NBC or other relevant BIS code.(q)Car Size : As per NBC 2016 or other relevant BIS code of latest edition..(r) Flooring:18-20mm thick granite flooring. (s) No of Entrance :One location - Front. 275 (t) Car Entrance : Automatic power operated centre opening, Stainless Steel, mirror finishDoor.(u) Landing Entrance : Automatic power operated centre opening, Stainless Steel, mirror finishDoor.(v) Clear opening for door : As per existing site.(w) Floor Designation : 0,1,2,3,4, 5(x)Indicators : Car & Landings: Direction & Position Indicator/ call registration LEDs(y)Roping : Lift rope shall be provided as perNBC-2016 andIS 14665 - 2001 (upto date) of tensile strength not less than 12.5 tonnes/cm square andfactor of safety shall be 8.6(z) Battery operated emergency Alarm & Light shall be provided. (aa) Full height Infra-red Light Curtain Door Safety shall be provided.(ab) Press & Speak Phone shall be provided for intercom system. (ac) Fireman switch shall be provided. (ad)Emergency Automatic Rescue Device (ARD) with suitable capacity maintenance free battery shall be providedfor elevation of passengers trapped in lift car during power failure between floors .The ARD shall work for 3 phase and single phase failure. 276 (ae) Overload Protection Device, Load Weighing Device(LWD)/OSG (overspeed governors) Electronic switch shall be provided.(af)Voice announcement system in the car shall be provided to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator. (ag)Micro- Stroke illuminated push buttons shall be provided.(ah) All landing door shall be one hour fire rated.(aj) Car door lock shall be provided.(ak) Auto drive recall, Automatic Fan & light switching off arrangements shall be provided.(al) Hand Rails : Stainless steel mirror finish handrails on rear sides in car panels. Full height and full width mirror finishedstainless steel (1.5mm) panel to be provided on all side above hand rails.(am) MS Pit Ladder shall be provided.(an) Door Operator : DC Door Operator (ao) Car operating panel : Square flush painted illuminated buttons in Stainless steel (Hairline).(ap) Car position indicator : Dot matrix (Red LED) scrolling display. (aq) Hall fixtures : 16 segment display hall button. 277 (ar) Hall fixtures face plate : Stainless steel (Hairline).(as) Hall button arrangement :Hall button with FPI.(at) Standard Features : Anti nuisance car cell protection, overload device, nudging, independent service belt inspection device. Emergency Firemans service. Emergency car light unit,Infrared curtain protection, door time protection, emergency alarm button, extra door time of lobby and parking, door open/close button, manual rescue operation, belt inspection drive and auto fan cut off.ON/OFF system to be synchronised withcar door opening/closing system.(au) Machine room ladder , where applicable should be provided by the contractor (av) Hoist way wiring, where requiredshall be provided by the contractor(av) Ventilation : High powered axial flow fan with suitable air throw of 600 CFM through a duct all around the car so that uniform air flow shall be available at all side of the car. 278 Design supply , install, testing & commissioning of Passengers lift electrically operated, microprocessor controlled, speed 1.5 meter/sec, lift withsingle speed motor 415 volts, 3 phase, AC 50Hz supply conforming to IS-14665, suitable to serve G+2 upper floors with ACVariable Voltage Variable Frequency (VVVF) Regenerative (Cosed loop) drive ( ACD3-MR drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendent, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, emergency automatic rescue device (ARD) system with standby power supply by using suitable capacity maintenance free battery, 3D infra red sensor in full height of door & built in voice announcement system in the carto announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator, announcing system without hand set ( 03 Nos, one each in car, Machine room & near ground floor landing door),Battery operated emergency light & alarm complete all as specified for 8 passenger as per the details given belowcomplete all as specified and directed:-(Location of lift :MES IB VD-01) 279 (a) Type & capacity: 8 Passenger, 544 Kgs - Gearless (b) Speed:1.5 M/Sec (c) Type of Drive:VVVF Regenerative (Closed Loop)(d) Type of control :Microprocessor based Simplex full Collective control (e) Location of Machine Room:Top of Building (As existing) (f)Machine : Gearless Machine(g) Travel :As per existing site to serve G+2 floor (h) Serving :G+ 2 upper floors- (3 Stops, 3 landings, 3 openings) (j)Existing Well size:As existing at site (as per Appx `A attached) 280 (k) Existing Pit depth : 1600 mm . (Existing Pit Depth is meeting the requirements of NBC , IS Codes and West Bengal Lift Rules. However if any modification is still required as per manufacturers recommendation the same shall be carriried out by Contractor without any extra cost to the Department) . Pit depth and overhead shall be such as to conform to the requirements of bottom clearance and top clearance as specified in IS: 14665. 281 (l) Head Room : As per existing site. (m) Power supply :415 volts Three-Phase, 50 Cycles AC. The entire lift equipment shall be suitable for operation at +10% to - 20% of rated supply voltage. (n) Auxiliary supply : 220 volts Single-Phase, 50 Cycles AC. (o) Earth connection : All new Earthing Points and Earth Contunity strips, connections Conductors shall be provided as per NBC, National Electrical Code and Code of Practices for Earhing. The cost of earthing and connected items shall be paid separaty under respective item of work in schedule.(p)Car Enclosure :Stainless Steel (Hairline) mirror finish body of car having minimum thickness of SS Sheet as 1.5 mm incl recessed LED light, false ceiling, as per NBC or other relevant BIS code.(q)Car Size : As per NBC 2016 or other relevant BIS code of latest edition..(r) Flooring:18-20mm thick granite flooring. (s) No of Entrance :One location - Front. 282 (t) Car Entrance : Automatic power operated centre opening, Stainless Steel, mirror finishDoor.(u) Landing Entrance : Automatic power operated centre opening, Stainless Steel, mirror finishDoor.(v) Clear opening for door : As per existing site.(w) Floor Designation : 0,1,2(x)Indicators : Car & Landings: Direction & Position Indicator/ call registration LEDs(y)Roping : Lift rope shall be provided as perNBC-2016 andIS 14665 - 2001 (upto date) of tensile strength not less than 12.5 tonnes/cm square andfactor of safety shall be 8.6(z) Battery operated emergency Alarm & Light shall be provided. (aa) Full height Infra-red Light Curtain Door Safety shall be provided.(ab) Press & Speak Phone shall be provided for intercom system. (ac) Fireman switch shall be provided. (ad)Emergency Automatic Rescue Device (ARD) with suitable capacity maintenance free battery shall be providedfor elevation of passengers trapped in lift car during power failure between floors .The ARD shall work for 3 phase and single phase failure. 283 (ae) Overload Protection Device, Load Weighing Device(LWD)/OSG (overspeed governors) Electronic switch shall be provided.(af)Voice announcement system in the car shall be provided to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator. (ag)Micro- Stroke illuminated push buttons shall be provided.(ah) All landing door shall be one hour fire rated.(aj) Car door lock shall be provided.(ak) Auto drive recall, Automatic Fan & light switching off arrangements shall be provided.(al) Hand Rails : Stainless steel mirror finish handrails on rear sides in car panels. Full height and full width mirror finishedstainless steel (1.5mm) panel to be provided on all side above hand rails.(am) MS Pit Ladder shall be provided.(an) Door Operator : DC Door Operator (ao) Car operating panel : Square flush painted illuminated buttons in Stainless steel (Hairline).(ap) Car position indicator : Dot matrix (Red LED) scrolling display. (aq) Hall fixtures : 16 segment display hall button. 284 (ar) Hall fixtures face plate : Stainless steel (Hairline).(as) Hall button arrangement :Hall button with FPI.(at) Standard Features : Anti nuisance car cell protection, overload device, nudging, independent service belt inspection device. Emergency Firemans service. Emergency car light unit,Infrared curtain protection, door time protection, emergency alarm button, extra door time of lobby and parking, door open/close button, manual rescue operation, belt inspection drive and auto fan cut off.ON/OFF system to be synchronised withcar door opening/closing system.(au) Machine room ladder , where applicable should be provided by the contractor (av) Hoist way wiring, where requiredshall be provided by the contractor(av) Ventilation : High powered axial flow fan with suitable air throw of 600 CFM through a duct all around the car so that uniform air flow shall be available at all side of the car. 285 Materials and labour for earthing as in repair complete with galvanised iron earth plate electrode 600 mm x600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtrdeep below ground level with top edge of the plate notless than 1.5 m below ground level connetced withgalvanised strip of size 25 x 4mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed by the Engr-in-Charge. 286 Supply and fixing in repair for earth continuity conductor or main earthing lead fixed to wall onporcelain insulator or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for wall/ roof etc. as required by 25X4mm galvanised iron strip complete all as specified and directed. 287 Supply and laying XLPE insulated PVC sheathed, armoured, aluminium conductor cable 1100 Volt grade 25 Sqmm 3.5 core in trench/duct/floor/wall with provision of saddle and lugs, joints etc including connection complete all as directed by the Engr-in-Charge. 288 Supply and fixingMCB TPN DB made up with sheet metal double door, phosphorised, power coated, neutral link, earth bar and din rail, 4 way TPN with 200 amps rated bus bar, 415 volts complete all as specified and as directed. 289 Supply and fixing isolator 40 Amps 415 Volts FP with rapturing capacity 10KAincluding taking down of old one complete all as specified. 290 Supply and fixingMCB 5 to 32 amps single polecomplete all as specified. 291 Supply and fixing MCB DP 40 to 63 amps 240 volts 10KA breaking capacitycomplete all as specified.
Contract Date : 28 Nov, 2025   |   Contract Value : 5.86 Crore
BRR : 8151333 Tender For Construction Of Munshi Prem Chand Library In Model Town, Mc Hisar.; 1 Dome Fixed Camera:Supply, installation, testing and installation of WDR 4MP IR Dome Camera, with 1/2.7” Progressive Scan CMOS H.265H.264. Resolution suppore: 4MP (2560×440), 1080P(1920x1080), 720P(1280x720), D1, CIF, 480 x 240,Focal Length 2.8mm/@F1.4,Min.IR distance upto 30m, Supports WDR, 3D DNR, HLC andBLC,Defog,Triple streams, Smart codec by ROI, Cyber Security-HTTPS / IP Filter / IEEE 802.1X / Blacklist and whitelist/ account security/ telnet access control /serial password,Video Analytics : Object removal (object left/missing detection), scene change and video blur detection, intrusion and line crossing.Edge Storage Built-in micro SD card slot, up to 128GB, Protection Level IP67 and IK10, Regulatory NDAA, Compatibility: Onvif S and G...(Make Honey well/Panasonic/Samsung) 2 Supply , Installation , Testing and commissioning of 32 Channel NVR (Network Vedio Recorder), for recording upto 64CH @ 1080P with 08 nos. SATA HDDs minimum 80TB storage or more (recording requirement all cameras recording at 2MP, 25fps for 30 days), H.265/H.264/MJPEG/MPEG4 codec decoding, Front Control Pannel with LEDs Indication, 3 nos. USB, iPhone: iPad: Android based Mobile clients, Video Export feature on USB, Search Mode: Time/ Date: Alarm: Motion Detection (MD): Exact Search (accurate to a second): Smart Search, Dual HDMI Output, Alarm Input (16 nos.), Alarm Output (4 nos.),eSATA Device, 320Mbps each Incoiming and Outgping throughput, Operating Temperature –10°C to 55°CCertification : CE, FCC and UL including fixing accessories and cable termination with required connectors/Jack, complete in all respect as per instruction of engineer in-charge. Redundancy features available in NVR ( If required take additionalNVR)..(Make Honey well/Panasonic/Samsung) 3 Supply, installation, testing and commissioning of 55` inches LED screensuitable for showing out puts from NVRs on a single screen(24x7)completein all respect complete as required. (Make Sony/LG/Samsung) 4 Supply, laying and and termination of CAT-6 Cable 23AWG solid bare electrolytic grade copper unshielded type cablein existing conduits/raceway/cable tray. Unshielded twisted pair cabling system, TIA / EIA 568-C.2 Category 6 Cabling system, CM/CMR rated.cable should be ETL Verified, UL Listed and UL channel verified- All three Certificates are mandatory.It should be IEEE 802.3ab - Zero-bit Error, ETL verified .cable Frequency tested up to 500 MHz. ..(Make Hikvision/Dahua Technology/Bosch) 5 Supply, installation, testing and commissioning of 8 TB Survillance HDD for camera recording.(24*7 )..(Make Hikvision/Dahua Technology/Bosch) 6 Supply, installation, testing and commissioning of Fiber patch cord 1 mtr. complete as required(Make Hikvision/ Dahua Technology/ Bosch) 7 Supply, installation, testing and commissioning of Cat -6 Patch cord 2 Mtr. complete as required...(Make Hikvision/Dahua Technology/Bosch) 8 Supply, Installation, Testing and Commissining of4 Reader Access Controller, On-board 10/100 Mbps Ethernet Communicates directly with the central system, Structured database allows storage of large amounts of cardholder records for off-line card validation, Reader communications via standard Wiegand/OSDP, Two relays (normally opened or closed) and open collector outputs, Self resetting fuses – saves maintenance time, A supervised input can be mapped to a physical out put, Onboard LED - provides visual status, Dedicated tamper input,Flash Memory 4GB, Storage 1 million cardholders at the door, Transactions1 million transactions in offline operation, Controller should be CE, FCC, UL294 Certified...(Make Honey well/Panasonic/Samsung) 9 Supply , installation, testing and commissioning of Multi Technologycards as per specification...(Make Honey well/Panasonic/Samsung) 10 Access Control Integrated Software :Supply, installation, testing and commissioning of Access control software, and integrated security management system, with AES 128 Bit of Encryption, Software should support Unlimited numbers of Cardholders, unlimited doors, lift Control, Database Partioning, Central Alarm Monitoring and Management, Integrated Photo ID Badging Client, Time and Attendance and Visitors management, Web Client. Software should support Redundacy Failover, and Seamless integration with multiple systems including access control, video, intrusion, fire and perimeter detection. ..(Make Honey well/Panasonic/Samsung) 11 Single Leaf Electro Magnetic Lock of Suitable Capacity(600 lbs) as per specification..(Make Honey well/Panasonic/Samsung) 12 DoubleLeaf Electro Magnetic Lock of Suitable Capacity(1200 lbs) as per specification..(Make Honey well/Panasonic/Samsung) 13 Supply, Installation, testing and commissioning of Push Button as required Entry/ exit from the Access..(Make Honey well/Panasonic/Samsung) 14 Supply, Installation, testing and commissioning of Megnatic Contact as requiredfrom the Door..(Make Honey well/Panasonic/Samsung) 15 Supply installation, testing and commissioning of 8 Core x 1 sq mm multi strand, copper, armored shieldedCable as per specification (between the every card readers and the access controllers) 16 Supply installation, testing and commissioning of 4 Core x 1.5 Sq mm, multi strand, copper, shielded, armoredcable as per specification (between controller, EM Lock, and push to exit button and door sensor) 17 Supply installation, testing and commissioning of External 12V 5amp or 24V 2.5 Amp 16 terminal Power Supply 18 SITC of All-in-One Desktop-computers 13th Gen Intel® Core™ i7, Windows 11, (Make :- Dell / HP) 19 `SITC of 42U (W 800mm/ D 800mm) Floor mount with front glass door and side panels with lock and key (load bearing capacity of 40Kgs), AC main Channel 12 points 5 Amp (PDU) with Mounting Hardware (Pack of 10) as per specification etc. all completeApproved Make: Valrack / Netrack /President` 20 `SITC of Rack Mountable Patch Panel, 24 Cat 6A Loaded Ports, Copper Patch Panel, Straight, Unshielded, Durability (IDC Life) 200 termination cycles with in Built Wire Manager, Grounding Bolt included as per specification etc. all completeApproved Make: Belden / 3C3 / Commscope / Siemon / Legrand ` 21 Supply, Installation, testing and commisioning of Switch 24 ports Cisco Catalyst 1000-24T-4G-L Network Switch, 24 Gigabit Ethernet Ports, 4 1G SFP Uplink Ports, (C1000-24T-4G-L) (MAKE CISCO) 22 Supply, Installation, testing and commisioning of wireless controller Network Management Device WAN Capable Air-CT2504-5-K9 Wireless Controller (MAKE CISCO) 23 Supply, Installation, testing and commisioning of Dual Band Wireless Access Point,(MAKE CISCO) 24 Supply, Installation, testing and commisioning of OI 25 Supply, Installation, testing and commisioning of Patch Cord 26 `SITC of Single Face Plate Shuttered, Provision for accepting any Keystone Style RJ45 Outlets, Capable of providing RJ45/ RJ11 type, Label Holders with Plastic covers, Built-in Dust Covers with Back boex as per specification etc. all completeApproved Make: Belden / 3C3 / Commscope / Siemon / Legrand ` 27 `SITC of Dual Face Plate Shuttered, Provision for accepting any Keystone Style RJ45 Outlets, Capable of providing RJ45/ RJ11 type, Label Holders with Plastic covers, Built-in Dust Covers with Back boex as per specification etc. all completeApproved Make: Belden / 3C3 / Commscope / Siemon / Legrand ` 28 Supply, Installation, testing and Commissioning of the following lighting fixtures with all fixing accessories etc. complete as required.(NS)…………… 30 Watt - 2x2 Recessed Mounted LIGHT MAKE - Philips 29 Supply, Installation, testing and Commissioning of the following lighting fixtures with all fixing accessories etc. complete as required.(NS)…………… 26 Watt - 1x4 Hanging and Pendant Lights MAKE - Philips 30 Supply, Installation, testing and Commissioning of the following lighting fixtures with all fixing accessories etc. complete as required.(NS)…………… 12-Watt Recessed LED (ROUND TYPE LED LIGHT) Philips 31 Supply, Installation, testing and Commissioning of the following lighting fixtures with all fixing accessories etc. complete as required.(NS)…………… 100-Watt FLOOD LIGHT Philips 32 Supply, erection, testing of 1200mm diaCeiling fans Stealth ES Wood Colourwith suitable GI pipe complete in all respects complete. Make (Havells / crompton) 33 MAIN LT PANEL (INBUILT CAPACITOR PANEL)Incoming Transformer400 amps 25 kA 440 volt FP EDO MCCB with overcurrent and short circuit and earth fault module, with heavy duty solid detachable neutral link Metering for incoming:3 nos 2500/5A Class 1, 15 VA Burden CT`s for metering and 1 nos associated Neutral CT for earth fault module. Digital flush type class -1.0 accuracy multifunction meter with RS-485 communication port for measurement of THD, KVARH KW, KWH, KVAR, PF, V, A, Hz, equivalent to EM6400 NG, with 3 Nos. current transformers of required ratio, 15 VA Class 1.0 Phase indication Lamp and ON/OFF indicating lamps with3X2A SP MCB as backup protection.Incoming DG400 amps 25 kA 440 volt FP EDO MCCB with overcurrent and short circuit and earth fault module, with heavy duty solid detachable neutral link Metering for incoming:3 nos 2500/5A Class 1, 15 VA Burden CT`s for metering and 1 nos associated Neutral CT for earth fault module. Digital flush type class -1.0 accuracy multifunction meter with RS-485 communication port for measurement of THD, KVARH KW, KWH, KVAR, PF, V, A, Hz, equivalent to EM6400 NG, with 3 Nos. current transformers of required ratio, 15 VA Class 1.0 Phase indication Lamp and ON/OFF indicating lamps with3X2A SP MCB as backup protection.Bus Bars:TPN Aluminium busbars aluminium three phase and neutral busbars rated at 600 amps, 25 KA, insulated with heat shrinkable coloured PVC sleeves and clip on shrouds for joints. Current density of Bus Bar to be 1.0 sq.mm / amp.Outgoing 1 nos. 315amps 25 kA 440 volt FP MCCB with overcurrent and short circuit and earth fault module, with heavy duty solid detachable neutral link complete with:Phase indication Lamp and ON/OFF indicating lamps with MCB as backup protection.Digital flush type class -1.0 accuracy multifunction meter with RS-485 communication port for measurement of KWHr,V, A, equivalent to EM6433 NG, with 3 Nos. current transformers of required ratio, 15 VA Class 1.0 1 nos. 100amps 25 kA 440 volt FP MCCB with overcurrent and short circuit and earth fault module, with heavy duty solid detachable neutral link complete with:3 nos. 40amps 25 kA 440 volt FP MCCB with overcurrent and short circuit and earth fault module, with heavy duty solid detachable neutral link complete with:1 nos. 200amps 25 kA 440 volt FP MCCB with overcurrent and short circuit and earth fault module, with heavy duty solid detachable neutral link complete with: (8 Nos. 63 Amp 4PMCB With breaking capacity of10KA MAIN LT PANEL complete as aboverequired. 34 VRV ODU PANEL (IP 55)Incoming:1 Nos. 315 Amp FP MCCB OF 16 KA Breaking CapacityMetering for incoming:3 nos 315/5A Class 1, 5 VA Burden CT`s for metering and 1 nos associated Neutral CT for earth fault module. Digital flush type class -1.0 accuracy multifunction meter with RS-485 communication port for measurement of PF, V, A, Hz, equivalent to EM6459 NG, with 3 Nos. current transformers of required ratio, 5 VA Class 1.0 Phase indication Lamp and ON/OFF indicating lamps with MCB as backup protection.Bus Bar:TPN Aluminium busbars aluminium three phase and neutral busbars rated at 400 amps, 16 KA, insulated with heat shrinkable coloured PVC sleeves and clip on shrouds for joints. Current density of Bus Bar to be 1.0 sq.mm / amp.Outgoing :5 nos. 100amps 16 kA 440 volt FP MCCB with overcurrent and short circuit and earth fault module, with heavy duty solid detachable neutral link complete with:1 nos. 100amps 16 kA 440 volt FP MCCB with overcurrent and short circuit and earth fault module, with heavy duty solid detachable neutral link complete with:1 Nos. 40 Amp 4PMCB With breaking capacity of10KA Complete Set as required above 35 Supplying installation testing and comissioning offollowing capacity True Online dual conversion(Pure Sine Wave), microprocessor based Online UPS System with five years warantee having pollution free instantaneous true sinewave control and without inbuilt isolation transformer, 3 Phase AC input and 3 phase AC output, LCD display and indication for various electrical parameters, LED indication with alarm for major fault, provision for remote indication and provision of communication to BMS system through RS 485/RS232/Modbus port etc. The UPS system shall be as per detailed specifications and shall be complete with parallel redundant kit, battery bank for providing 30 minutes backup time with SMF batteries having minimum 2 years warrantee, with all connections interconnections cables, MS stand for battery bank etc. complete as required Specifications of UPSa) Capacity : 20 KVA Capacity Online UPS System b) Technology : True Online dual conversion(Pure Sine Wave) Input Parametersa) Input Voltage range : 352-475VAC, 3-F AC Supply b) Rated frequency : 50Hz/ 60 Hz ± 10%c) UPS Power factor: 0.99 or better laggingd) Harmonic distortion: with Linear load =3%Output Parametersa) Rated Voltage: 415 V ± 10%b) Frequency: 50Hz ± 0.5Hzc) Output wave form: Pure sine wave`d) Overload capacity: 150% of rated load for 1 minutes125% of rated load for 10 minutes`General Parametersa) Ambient operating temp: Upto 40º C or betterb) Noise Level : = 65 db at 1.5m distance or betterc) Overall efficiency: 94% or betterd) Computer interface: RS232 / RS485e) Cooling: Forced Coolingf) Bypass: Manual/Static 36 GI RACEWAYIN FLOOR/ SCREED RACEWAYSupply and Fixing of factory fabricated pre-galvanised sheet steel raceway in 2mm thickness for bottom and sides and 2mm/ 3mm thick top cover including openable top cover floor junction boxes made from 2mm thick pre-galvanised GI sheets for bottom and sides and 3mm thick GI top cover complete with rubber gasketing beneath the top cover. The junction box shall be suitable to accommodate GI floor raceways as specified above, as called for including necessary civil work such as chase cutting in screed, fixing/ jamming the raceway, aligning and leveling and finishing with sand cement plaster and chicken wire mesh:40mm Depth100mm x 40mm (2mm top cover) 37 GI RACEWAYIN FLOOR/ SCREED RACEWAYSupply and Fixing of factory fabricated pre-galvanised sheet steel raceway in 2mm thickness for bottom and sides and 2mm/ 3mm thick top cover including openable top cover floor junction boxes made from 2mm thick pre-galvanised GI sheets for bottom and sides and 3mm thick GI top cover complete with rubber gasketing beneath the top cover. The junction box shall be suitable to accommodate GI floor raceways as specified above, as called for including necessary civil work such as chase cutting in screed, fixing/ jamming the raceway, aligning and leveling and finishing with sand cement plaster and chicken wire mesh:40mm Depth150mm x 40mm (2mm top cover) 38 `Supplying and placing in position 6 seater PU coated canteen table.Over all size of table shall be 1734 Width mm x 1175 Depth mm x 750 Height mm . Top shall be 25 mm thick( plus /-1mm) base material shall be 25 mm MDF board . On top PU painting of minimum 2H hardness with 75% glass.Combination color of graphics shall be on the centre . The Understructure shall be having bend pipe structure of MS powder coated . Pipe dia shall be of 38 mm , 2 mm thick and it shall be fitted with top by SS machine screws . Legs shall be of MS powder coated and 38 mm dia. pipe legs shall be fixed with understructure and table top . Glide shall be of Plastic fixed at the understructure to prevent the damage of table top` 39 `Supplying and placing in position canteen chair. The seat and back shall be made up of injection moulded high impact strength polypropylene polymer with indoor gate UV resistance. The dimensions of back shall be 51.6cm. (W) X 40.5cm. (H) and of seat shall be 52.5cm. (W) X 53.2cm. (D). The powder-coated (DFT 40-60 microns ) frame structure shall be made of 3.5±0.03cm x 1.5±0.03cm x 0.16±0.0128cm thk M.S. E.R.W. tube and welded connecting tube made of dia 2.22±0.03cm x 0.16±0.0128cm thk M.S. E.R.W. SQUARE tube. The shoes shall be made of high impact strength polypropylene polymer compound with indoor grade UV resistance and pressed fitted with tubular frame. Product shall be Green Guard (UL)` 40 `Supplying and placing in position Library table. Over all size of the table shall be 1800 W x 900 D x 740 H mm . The top shall be 25 mm thick PLB with 2 mm thick PVC Edge Beading. Understructure shall be having C - Frames 1.6 mm thick MS supporting the top . The Legs shall be of dia. 38.1 x 1.6 mm thick MS ERW tube .` 41 `Supplying and placing in position revolving chair. The seat assembly shall be made up of 1.2 ±0.1cm. thick hot-pressed plywood and shall be upholstered with fabric upholstery covers and moulded Polyurethane foam. The dimensions of seat shall be 47.0 cm. (W) x 48.0 cm. (D). The back asembly shall be made of powder coated (DFT 40-60 microns) tubular frame of dia 2.54 ±0.03cm. x 0.2±0.016cm thk. MS ERW tube designed with contoured lumbar support for extra comfort. The back shall be upholstered using Net fabric with high tenacity yarn. The dimensions of back shall be 46.5 cm (W) x 60.5 cm (H). The HR polyurethane foam shall be moulded with density =45 plus /-2 kg/m3 and hardness load 16 ± 2 kgf as per IS:7888 for 25% compression. The one-piece armrests shall be injection moulded from black Co-polymer Polypropylene. The mechanism shall be designed with 360° revolving type, 17±2° maximum tilt m pivot at centre, Upright position locking., Tilt tension adjustment. The pneumatic height adjustment shall has an adjustment stroke of 11.0 ±0.3cm. The bellow shall be 3 piece telescopic type and injection moulded in Black Polypropylene. The pedestal shall be injection moulded in black 33% glass-filled Nylon66 and fitted with 5 nos. twin wheel castors. The pedestal is 66.3 ±0.5cm. pitch-center dia. (76.3 ±1.0cm with castors). The twin wheel castors shall be injection moulded in Black Nylon. Overall Dimensions of Chair shall be Seat Height - min 43.3 to max 54.3cm, Height - min89.5 to max 100.5cm, Width and Depth of Chair as measured from pedestal - Width-76.3 cm and Depth-76.3 cm` 42 `Providing and Placing in position 3 seater Sofa. Upperstructure shall be a single shell 1.2 ±0.1cm. thick hot pressed plywood. Dia 4mm zig-zag type assembly is mounted in the understructure for support and additional cushioning purpose. The seat is made up of PU foam with density 32 plus /-2 Kg/m3 having an additional top layer of PU foam with density 28 plus /-2 Kg/m3, upholstered with fabric or leatherette. The back is made up of 28 plus /-2 Kg/m3 with additional top layer of PU foam with density 23 plus /-2 Kg/m3, upholstered with fabric or leatherette. The leg is a welded assembly made up of stainless steel (grade SS 202) tube and plate. Overall Dimensions of Chair shall be Seat Height - 45.0 cm, Height - 82.0cm, Width and Depth of Chair as measured from pedestal - Width-205.5 cm and Depth-92.0 cm.` 43 `Supplying and placing in position of Center Table. Overall size of the table shall be 1000mm(L) x 600mm(D) x 425mm(H). Understructure of the table which includes Legs, top wooden frame and bottom tie members shall be made out of first quality rubberwood of approved make without knots and defects on all faces. Legs shall be provided of size 75mm(W) x 35mm((D) at the top side and 35mm(W) x 20mm(D) at the bottom. Bottom tray shall be made of 1.2mm thick MS sheet. Metal brackets shall be used for assembly purpose. Top: 8mm thick toughened glass with crystal edge polish finish. Construction: Knock down assembly.Wooden members shall be PU painted with hardness-2H. Metal components shall be powder coated. Bottom MS metal tray shall having floral pattern laser-cut. Top glass shall having sand blasted floral pattern on bottom surface 5. Hardware: Knock-down assembly with high quality standard hardware like screws, metal inserts, wooden dowel, plastic leg bush.` 44 `Supplying and placing in position of Corner Table. Overall size of the table shall be 500mm(L) x 500mm(D) x 425mm(H). Understructure of the table which includes Legs, top wooden frame and bottom tie members shall be made out of first quality rubberwood of approved make without knots and defects on all faces. Legs shall be provided of size 75mm(W) x 35mm((D) at the top side and 35mm(W) x 20mm(D) at the bottom. Bottom tray shall be made of 1.2mm thick MS sheet. Metal brackets shall be used for assembly purpose. Top: 8mm thick toughened glass with crystal edge polish finish. Construction: Knock down assembly.Wooden members shall be PU painted with hardness-2H. Metal components shall be powder coated. Bottom MS metal tray shall having floral pattern laser-cut. Top glass shall having sand blasted floral pattern on bottom surface 5. Hardware: Knock-down assembly with high quality standard hardware like screws, metal inserts, wooden dowel, plastic leg bush` 45 `Supplying and placing in position 6 Door Locker unit. Overall size shall be 375W x 470D x 1950H mm . Height shall be including of leveler which shall be 50mm H and possible adjustment shall be 15mm. Construction shall be knock down type. Legs shall be fitted with screw type leveler. Top, side, bottom, back panel and end cover shall be made form 0.5 mm CRCA sheet D Grade as per IS -513. Top bottom stiffner shall be made from 1.2mm CRCA sheet D Grade as per IS -513. Doors shall be made from 0.6mm thick CRCA (D Grade , IS -513). Soft closing hinge shall be provided. Door size shall be 373W x 18T x 314H. Shelve shall be a 10 bend panel made of 05 mm thick CRCA ( D Frade as per IS - 513) . Uniformly distributed load capacity of each shelf shall be 20 kg. 5 shelves shall be provided for 6 door locker unit. Lock shall be of cam lock with follwing specification : Oval knob that shall be function as a handle. Click action mechanism there. Key removal in locked and unlocked position. Zinc alloy die cast housing. Product shall be Green Guard (UL) certified.` 46 `Providing and Placing in position meeting Table. Overall size of the Table shall be 3600 W mm x 1500 D mm x 740 H mm. Top shall be made of 36mm thick MDF one side prelaminate board with 0.4mm PVC membrane pressed on to top and shall have chamfered edge. Plastic ABS access flap shall be provided for easy access to wires and cables. The Understructure shall be made of mixture of 25mm and 18mm Pre-laminated twin board of E1-P2 grade, Edge banded with matching 2 mm thick PVC lipping. Aluminium alloy 63400 - WP profile shall be used for connecting panels together. Modesty Panel shall be made of 18mm Thick Pre-laminated twin board of E1-P2 grade, Edge banded with matching 2 mm thick PVC lipping. Powder coated accent metal strip shall be provided below work surface to enhance aesthetics. It shall be made of 0.8mm CRCA as per IS 513, and shall be epoxy polyester powder coated (DFT 40-60 microns). Wire Management shall be an array of panels made of 0.8mm CRCA MS IS:513, and shall be epoxy polyester powder coated (DFT 40-60 microns) shall be used for flow of wires and cables. Provision to mount 6 module switch plate shall be provided below worktop. Cutout on top with two piece injection moulded plastic part polymer component shall be fitted to pullout audio,video cables onto worktop and connect devices charger to power socket below worktop. Product shall be Green Guard (UL) certified..` 47 ` Providing and Placing in position High Back Chair. Overall size of 76.1 cm W x 76.1 cm D x 112.7 – 130.2 cm H x 43.1 – 53.1 cm Seat Height. The seat is cushioned seat made of injection molded plastic outer and inner. Plastic inner is upholstered with leatherette and molded high resilience polyurethane foam of density 45±2 kg/m³, and hardness load of 16±2 kgf as per IS:7888 for 25% compression. Seat Size is 47.0 W cm x 48.0 D cm. The back is cushioned made of PU foam with insitu molded M.S. ERW round tube of size 1.9±0.03cm x 0.16±0.0128cm, upholstered with leatherette. The back size is 47.7 W cm x 76.4 D cm. The armrest top is molded from polyurethane and mounted on to a drop lift adjustable type tubular armrest support made of Ø3.81±0.03cm x 0.2±0.01cm thick M.S. ERW tube having chrome plated finish. The armrest is height adjustable up to 6.5±0.5 cm in 5 steps. The adjustable tilting mechanism is designed with following features : 360° revolving type, front-pivot for tilt with feet resting on ground and continuous lumbar support ensuring more comfort, tilt tension adjustment can be operated in seating position, 5-position tilt limiter giving option of variable tilt angle to the chair, Seat/back tilt ratio 1:2, The mechanism housing is made up of HPDC aluminium black powder coated. Seat depth adjustment is integrated in the seat through a sliding mechanism. Seat depth adjustment range is of 6.0±0.5cm. Back frame is connected to the up/down mechanism in plastic T spine. It can be adjusted in the range of 7.42±0.5 comfort the comfortable back support to suit individual need. The pneumatic height adjustment has an adjustment stroke of 10.0±0.3cm. The pedestal is high pressure die cast polished aluminium and fitted with 5 nos. of twin wheel castors. The pedestal is 65.0±0.5cm pitch centre dia. (75.0±1.0cm with castors). 5 nos. of twin wheel castors are injection molded in plastic having 6.0±0.1cm wheel diameter and assembled to pedestal. Product shall be Bifma level 2 certified.` 48 ` Providing and Placing in position Chair for visitor. Overall size of 76.1 cm W x 76.1 cm D x 96.5 – 114.0 cm H x 43.1 – 53.1 cm Seat Height. The seat is cushioned seat made of injection molded plastic outer and inner. Plastic inner is upholstered with leatherette and molded high resilience polyurethane foam of density 45±2 kg/m³, and hardness load of 16±2 kgf as per IS:7888 for 25% compression. Seat Size is 47.0 W cm x 48.0 D cm. The back is cushioned made of PU foam with insitu molded M.S. ERW round tube of size 1.9±0.03cm x 0.16±0.0128cm, upholstered with leatherette. The back size is 47.7 W cm x 60.1 D cm. The armrest top is molded from polyurethane and mounted on to adrop lift adjustable type tubular armrest support made of Ø3.81±0.03cm x 0.2±0.01cm thick M.S. ERW tube having chrome plated finish. The armrest is height adjustable up to 6.5±0.5 cm in 5 steps. The adjustable tilting mechanism is designed with following features : 360° revolving type, front-pivot for tilt with feet resting on ground and continuous lumbar support ensuring more comfort, tilt tension adjustment can be operated in seating position, 5-position tilt limiter giving option of variable tilt angle to the chair, Seat/back tilt ratio 1:2, The mechanism housing is made up of HPDC aluminium black powder coated. Seat depth adjustment is integrated in the seat through a sliding mechanism. Seat depth adjustment range is of 6.0±0.5cm. Back frame is connected to the up/down mechanism in plastic T spine. It can be adjusted in the range of 7.42±0.5 comfort the comfortable back support to suit individual need. The pneumatic height adjustment has an adjustment stroke of 10.0±0.3cm. The pedestal is high pressure die cast polished aluminium and fitted with 5 nos. of twin wheel castors. The pedestal is 65.0±0.5cm pitch centre dia. (75.0±1.0cm with castors). 5 nos. of twin wheel castors are injection molded in plastic having 6.0±0.1cm wheel diameter and assembled to pedestal. Product shall be Bifma level 2 certified.` 49 `Providing and placing of panel and tile based modular workstations with partition thickness of 50 mm thick including powder coated aluminium trims and supported on Legs for better air circulation and helps in keeping floor clean. Product shall be Bifma level 2 certified.` 50 `Supplying and placing in position Main Table and ERU of the following specifications.1650x1650x750 Primary Work Surface shall be Made of 25mm thick MDF one side pre-laminate board confirming to IS-14587:1998 with0.4mm PVC membrane pressed on to top.Softclosing access flap with in-build power box are provided on work surface for wire management.Secondary Work Surface shall be Made of 25mm thick MDF one side pre-laminate board confirming to IS-14587:1998 with 0.4mm PVC membrane pressed on to top.Modesty Panel shall be Made of 25mm thick MDF one side pre laminate board confirming to IS-14587:1998 with 0.4mm PVC membrane pressed on to top.understructure:Made of 25mm Thick Pre-laminated twin board of E1-P2 grade and approved shade confirming to IS-12823:1990, Edge banded with matching 2 mm thick PVC lipping.integrated pedestal:Made of 25mm Thick Pre-laminated twin board of E1-P2 grade and approved shade confirming to IS-12823:1990, Edge banded with matching 2 mm thick PVC lipping. Drawer fronts shall be made of 25mm thick MDF one side pre-laminate board confirming to IS-14587:1998 with 0.4mm PVC membrane pressed on to top Pedstal construction shall be BOX-BOX-FILE type which Uses powder coated 400 MM long metal. Panel Drawer Slides. Drawer extension shall be 325 MM.Drawers have a soft closing and anti slam mechanism.Handles shall be provided for ease of opening.Pedestal is provided with lock for security. Product shall be Green Guard (UL) certified.` 51 `Supplying and placing in position Revolving Chair. SEAT/BACK ASSEMBLY: The seat shall be made up of 1.5 ±0.1cm. thick hot-pressed plywood and upholstered with fabric upholstery covers and moulded Polyurethane foam. The seat shall have extra thick foam on front edge to give comfort to popliteal area. The Back shall be injection moulded in glass filled Polypropylene which shall be upholstered with Mesh fabric.The back consist of adjustable lumbar support made of injection moulded Polypropylene having an adjustment of 5.0 ±0.1 cm. The chair seat and back size shall be *SEAT SIZE 53.5 cm. (W) x 51.0 cm. (D)*MESH BACK SIZE 51.0 cm. (W) x 70.0 cm. (H). HIGH RESILIENCE (HR) POLYURETHANE FOAM: The HR polyurethane seat foam shal be moulded with density 45±2 kg/m³ and hardness 16±2 kgf as per IS:7888 for 25% compression. ARMRESTS :The adjustable armrest is designed with the following features :· Up-Down adjustment– 6 steps (7.2 ± 0.5cm range). Armrest top shall be mounted on Armrest structure made of glass filled Nylon· Armrest Top shall be PU moulded over glass filled Nylon insert. CENTER TILT SYNCHRO MECHANISM WITH MULTI LOCK : The mechanism shall be designed with the following features: 360° revolving type, 3 position locking with anti shock mechanism, Tilt tension adjustment. The complete headrest assembly shall be retro fit to the main chair. PNEUMATIC HEIGHT ADJUSTMENT: The pneumatic height adjustment with anadjustment stroke of 9.5 ± 0.3cm. PEDESTAL ASSEMBLY : The pedestal is injection moulded in glass-filled Nylon andfitted with 5 nos. twin wheel castors. The pedestal is 66.1 ±0.5cm. pitch-center dia.(76.1 ±1.0cm with castors). TWIN WHEEL CASTORS : The twin wheel castors are injection moulded in Black Nylon. Product shall be Bifma level 2 certified.` 52 `Supplying and Placing in position Visitors Chair. The cushioned seat assembly shall be made of injection molded plastic inner and outer. Plastic inner shall be upholstered with foam laminate fabric and moulded high resiliance polyurethane foam of density 45 plus /-2 per cubic metre and hardness load of 16 plus /-2 Kgf. Seat size shall be 46 cm W x 48 cm D. Thecushioned back shall be made of PU foam with insitu molded MS ERW round tube of size 1.9 plus /-0.03 x 0.16 plus /-0.0128 cm. it shall be upholstered with foam laminate fabric. Back size shall be 46.6 cm W x 59.6 cm H. The powder coated tubular frame shall be cantilever type and shall be made of 2.54 plus /-0.03 x 0.2 plus /-0.016 cm thick MS ERW tube. The back shall be connected to the frame through powder coated high pressure die cast connector piece.` 53 `Supplying a d placing in position of Almirah. Overall size Shall be 916mm(W)x486mm(D)x1981mm(H) with welded construction. It shall have the shelf thickness of 0.7 mm, Back thickness of 0.8mm, Door thickness of 0.8mm (high yield strength) and all other components shall have a thickness of 0.9mm. These components shall be made of CRCA ‘D’ grade high yield strength as per IS:513. It shall have a Mazak handle and Three way locking mechanism with Shooting Bolts. It shall have a height wise adjustable shelf mounting which shall have a Uniformly Distributed Load Capacity of max 40 Kg. It shall also have a M10 Screw type Leveller with Hex plastic base. The finishing shall be include Epoxy powder coated to the thickness of 50 microns ( plus /- 10). Product shall be Green Guard (UL) certified` 54 `Supplying a d placing in position activity table. Worktop shall be made from 18mm thk Pre-laminated twin board (E1/P2GRADE) with 1.3mm thk PVC lipping on all sides. Worktop corners shall be rounded for safe usage. Top fixing plate shall be of 5mm thk HR (IS2062) plate shall be used for fixing the worktop with the leg assembly. LEG ASSEMBLY shall be Dia 76.2mm x 1.2mm thk MS ERW Round tube (IS:7138) shall be Argo Welded with 5mm THK HR (IS:2062) plate on both ends. It shall be coated with min. 45 micron thickness of epoxy polyester coating. BASE PLATE - 8mm thk HR (IS:2062) sheet shall be Argo welded with Dia 20mm MS Rod Bushes and shall be coated with min. 45 micron thickness of epoxy polyestercoating. Set of castors with and without lock shall be used for ease of mobility of the table. Overall size of tha table shall be 834W x 750D x 583 H` 55 `Supplying a d placing in position chair. Seat back shall be made of blow molded High-density polyethylene and is fixed on the understructure assembly with the help of Stainless steel pop rivets. Seat shall be made of blow molded High-density polyethylene and is fixed on the understructure assembly. All side metal frames and cross connectors shall be made from Mild steel ERW Oblong tubes , 40 x 20 x 1.6mm thk as per IS:7138 which shall be welded together. The Welded structures and cross connectors shall be coated with min 45 micron thickness of epoxy polyester coating. Seat support channelshall be made of 1mm thk Mild steel sheet (as per IS:513) shall be welded to the understructure for fixing seat. The understructure shall be provided with fixed caps on front side and shoes with adjustable levelers on rear side that shall be fixed with the help of stainless steel pop rivets. The caps and shoes shall be injection molded in co-polymer Polypropylene . The levelers shall be injection molded in Nylon providing adjustability from 5mm to 10mm. Over all size of the chair shall be 473 W1 x 474 D1 x 334D2 x 722 H1 x 351 Seat Height (H2).` 56 `Supplying a d placing in position pouff seating The inner structure shall be made with a combination of 12mm thk Plywood (As per IS:303) and Pine-Wood members. It shall be covered from the sides using 2mm kraft-board. Complete understructure is made by gluing, nailing and stapling. Seat shall be made of 100 mm PU Slab-stock Foam pasted on top of this structure. The understructure shall be covered with a layer of 12mm PU Slab-stock Foam around the sides. The structure shall be upholstered with Leatherette on the sides and top. Over all size shall be 420Dia x 330 H.` 57 `Supplying a d placing in position cubby . Overall size shall be 1378W x 460D x 1556 Height with leveller. Construction shall be rigid knock down type. All side panels,top/bottom panels, and shelf panels shall be made from 18mm thick pre–laminated board of E1-P2 grade and approved shade confirming to IS 12823:1990 with 2mm thick PVC edge lipping. Back panel shall be made from 9mm thick pre–laminated board with 0.8mm thick PVC edge lipping.. Metal Frame : The Metal Frame shall be fabricated by Argo Shield welding of MS ERW Tube 40 mm x 20 x 1.2 mm thk (IS:7138) along with 3mm thk HR (IS 2062) L-shaped plate on both sides of the frame. Dia 28 MS Bar shall be used as a bush for supporting the levelers at the bottom of the frame. M10 leveler molded with Nylon-6 along with a circular powder coated aluminium extrusion shall be used for height adjustment upto 20mm. Name Tag shall be made out of Clear Polycarbonate is provided with 200 GSM paper. 12 nos. of fixed shelves shall be providded with 350 mm clear space. Uniformly distributed load capacity per each shelf shall be 24kg` 58 `Supplying a d placing in position activity table. Worktop shall be made from 18mm thk Pre-laminated twin board (E1/P2GRADE) with 1.3mm thk PVC lipping on all sides. Worktop corners shall be rounded for safe usage. Top fixing plate shall be of 5mm thk HR (IS2062) plate shall be used for fixing the worktop with the leg assembly. LEG ASSEMBLY shall be Dia 76.2mm x 1.2mm thk MS ERW Round tube (IS:7138) shall be Argo Welded with 5mm THK HR (IS:2062) plate on both ends. It shall be coated with min. 45 micron thickness of epoxy polyester coating. BASE PLATE - 8mm thk HR (IS:2062) sheet shall be Argo welded with Dia 20mm MS Rod Bushes and shall be coated with min. 45 micron thickness of epoxy polyestercoating. Set of castors with and without lock shall be used for ease of mobility of the table. Overall size of tha table shall be 834W x 750D x 763 H` 59 `Supplying and placing in position 4 door bookcase. Overall size shall be 914mm(W)x320mm(D x1742mm(H). The unique design shall provides the right rigidity to the Top hinged doors , which shall facilitate easy use. The Book Case shall be made from prime quality CRCA steel with anti rusting treatment. It shall have a Rigid Knock Down Construction. The Top Pannel, Back Pannel and Side Pannel are made from 0.7mm high yield CRCA and other components from 0.8mm CRCA. Each door shall have a 6 Lever Cam Lock with Common Key. 3mm thick glass should be used in each door for clear inside vision whih shall be secured in a metal frame through a rubber gasket. Scissor Mechanism shall be provided in each door for receding inside the top of every compartment and it shall ensure parallel and smooth movement. Each door shall be provided with plastic side end caps as handle which is easy to grip. Each compartment shall have a storage shelf with a UDL capacity of max 80 Kg. The finishing shall include Epoxy powder coated to the thickness of 50 microns ( plus /- 10). Product shall be Green Guard (UL) certified.. ` 60 `Supplying and placing in position 3seater bench. The seat shall be a welded assembly of seat,back and side frame. The seat and back shall be made of 0.12±0.013cm thk CR steel sheet with oblong perforations.They shall be welded to sideframe of size 3.2±0.05cm x 0.5 ± 0.05 cm thk HR steel. The welded assembly shall be powder coated ( DFT 40-60 microns). The seat shall has a front water fall edge to provide popliteal clearance for comfortable seating. It also shall has a buttock support curve that not only provides rear support but also prevents small children from falling through the gap between seat and back. Clean and flat surfaces of seat and back shall aids in easy maintenance. The dimensions of seat shall be 47.8 cm (W) x 44.6 cm (D) and of back shall be 41.6 cm (W) x 23. cm (H). Understructure assembly shall consists of connecting beam and leg assembly made of M.S.E.R.W. oblong tube of size 7.5±0.03cm x5.0±0.03cm x 0.02±0.016cm thk.The welded structure assembly shall be powder coated (DFT 40-60 microns ).The leg assembly shall be fitted with shoes and levellers in Nylon. The leg structure shall be designed with minimal area of contact close to ground providing easy access for cleaning purposes. The shoes fiited to leg assembly shall help inaligning the structure for back to back arrangements. Levelers should take care of uneven flooring .Connecting beam shall be fitted with snap locking end cap.It also aids in side-by-side understructure alignment. Armrest assembly shall consists of armrest frame and armrest pad. The armrest frame shall be made up of size 3.175±0.05cm x 0.47±0.027cm thk HR steel and it shall be powder coated (DFT 40-60 microns). Armrest pad shall be injection molded in Nylon and shall be fitted onto the armrest frame. Overall Dimensions shall be Seat Height - 44.1 cm, Height - 78.5 cm, Width and Depth of Chair as measured from pedestal - Width-169.5cm and Depth-63.8 cm.` 61 `Providing and placing in position double sided book rack: Overall Size shall be WxHxD - Double Body 1200W x 600 D x 2078HBody - Side panels, Frame and Cross L bracket are made using 0.8 mm CRCA (IS:513). The assembly shall consists of 2 tie rods, 4 fixing brackets and 2 turnbuckles in each body. The tie rods shall be fixed in a shape of ‘X’ The tie rods are made of 4mm diameter rods of MS while fixing brackets are made of 2mm thick. CRCA IS:513 Grade. Under Structure - Under structure shall be made of 0.8m CRCA (IS:513). b. Sizes of under structure for Double body : 1200W x 595D x 80H. Shelves - a. Shelves used are 10 bend panel made of 0.8mm CRCA (IS:513). Shelf panels shall be placed on shelf support and then fixed using nut and bolts from below. Standard config. consists of 6 loading levels formed by 5 no of adjusted shelf for eachunit. Uniformly Distributed Load Capacity per each shelf is 80 Kg maximum. Construction- construction shall be Completely Knock down Finish- All MS sheetmetal and metal frame components are powder coated with epoxy polyester powder to the min thickness of min 45 microns. Label Holder -It shall be an aluminum extrusion of length 596mm for double body bookrack , fitted on to front of body. The Paper shall be 300GSM matt finish, to be inserted into the aluminum extrusion. The length of paper shall be 596mm for double body bookrack. Wooden panel of 25mm thk PLT, E1-P2 grade board for PLTr should be provided. Edges shall be provided with machine pressed 2 mm thick PVC lipping glued with hot melt EVA glue. Product shall be Green Guard (UL) certified` 62 Providing and placing in position mattress. Mattress shall be of two layers foam mattress. Over all size of matress shall be1980 L x 914W x 125 H mm. Mattress cover fabric composition shall be polyster. 63 `Providing and placing in position Reception table. Work Surface shall be Made of 25mm Thick Pre-laminated twin board of E1-P2 grade and approved shade confirming to IS-12823:1990, Edge banded with matching 2 mm thick PVC lipping. Access Flap along with a Gromett shall be provided on work surface for wire management Wire Management - Power box shall be made with 0.8 mm thick CRCA (IS: 513), with switch plate (8 plus 3 Module cut out provision for Anchor Roma) which is fixed with worktop along the width at Access Flap position. Modesty Panel and Side Skirting shall be Made of 25mm Thick Pre laminated twin board of E1-P2 grade and approved shade confirming to IS-12823:1990, Edge banded with matching 2 mm thick PVC lipping. Understructure -Understructure shall be Made of 18mm Thick Pre-laminated twin board of E1-P2 grade and approved shade confirming to IS-12823:1990, Edge banded with matching 2 mm thick PVC lipping. TOP shelf shall be Made of 18mm Thick Pre-laminated twin board of E1-P2 grade and approved shade confirming to IS-12823:1990, Edge banded with matching 2 mm thick PVC lipping. Hinge DoorplusDrawer unit shall be Made of 18mm Thick Pre-laminated twin board of E1-P2 grade and approved shade confirming to IS-12823:1990, Edge banded with matching 2 mm thick PVC lipping. **Drawer bottom shall be made of 5.5thk MDF whiteboard. Handle shall be provided for ease of opening. HDU and Drawer shall be provided with cam lock for security. Wire Riser shall be made of 0.8mm CRCA (IS-513) shall be provided for proper wire management. Organizer Plateshall be made of 1.2mm CRCA (IS-513) is provided for magnetic sticky notes. Bag Hanger Hook shall be made of 1.2mm CRCA (IS-513) is provided for bag hanging. Overall size of the table shall be 2400 Lmm x1770Dmm x740Hmm. Product shall be Green Guard (UL) certified.` 64 `Providing and placing in position Chair with Desklet. The seat and back shall be made up of injection moulded high impact strength polypropylene polymer with indoor gate UV resistance. The dimensions of Back shall be 51.6cm. (W) X 40.5cm. (H) and of seat shall be 52.5cm. (W) X 53.2cm. (D). The powder-coated (DFT 40-60 microns ) frame structure shall be made of 3.5±0.03cm x 1.5±0.03cm x 0.16±0.0128cm thk M.S. E.R.W. tube and welded connecting tube made of dia 2.22±0.03cm x 0.16±0.0128cm thk M.S. E.R.W. SQUARE tube to form the Mainframe assembly. The shoes shall be made of high impact strength polypropylene polymer compound with indoor grade UV resistance and pressed fitted with tubular frame. The paper tray shall be made of dia 0.4plus /- 0.005cm M.S. rod which is spot welded to form a mesh typestructure. It shall be powder coated(DFT 50 plus /-10 microns). The size of the tray is 40.1 (W) x 36.1 (D) x 22.0 (H) cm. Product shall be Green Guard (UL) certified.` 65 Supplying, installing, testing and commissioning of gun metal chrome finished Ball Valve for Drain connection.50mm dia. 66 ABC powder type fire extinguisher of 6 Kgs. Capacity, with initial filling (Mono Ammonium Phospate Powder) in brand new cylinder with powder coated finish, Stored Pressur type, Pressure Gauge, Controllable discharge mechanism with Hose and Nozzle , confirming to IS:15683:2008. 67 Carbon-di- oxide type fire extinguisher of 4.5 kgs. Capacity, Co2 gas as per IS 15222 with controll discharge mechanism fitted with Hose and Horn applicable on Class B fire rating 21Bconfirming to IS: 15683:2008. CO2 Cylinder as per IS 7285 with ISI mark. 68 Signages with printed `IN CASE OF FIRE, USE STAIRS UNLESS INSTRUCTED OTHERWISE` of 1.5cm height letters in red with white back ground. The size of the board shall be 25cm * 30cm and shall be fixed at the height of 2mts, from finished floor near Manual Call Points. 69 Floor indentification signage (i.e, GROUND FLOOR… ETC.,) at each stair enclosure on every floor, indicating the floor number in words, lettering size shall be 7.5cm with contrasting colour from back ground. Size shall be 15cm * 60cm. 70 Providing and fixing in position the signage of ` Fire Extinguisher ` to be pasted immediately above the every extinguisher. Sticker type 71 Providing and fixing in position the signage of ` Fire Hydrant and Hose Reel ` to be pasted on door of the every fire shaft at all floors. Sticker type 72 Supplying and fifing of fire brigade connection of cast iron body with gunmetalmale instantaneousinletcouplingscomplete withcapand chain asreqd. forsuitable diaMS pipe connection conforming to IS 904 as required :4 way - 150 mm dia M.S. Pipe 73 Supplying and fifing of fire brigade connection of cast iron body with gunmetalmale instantaneousinletcouplingscomplete withcapand chain asreqd. forsuitable diaMS pipe connection conforming to IS 904 as required :2 way - 150 mm dia M.S. Pipe 74 Supply and fixing of following size sprinkler hanger with threaded rod , hanging rod , fasteners Rubber lining zinc plated suitable to hang follwing size sprinkler pipe as required.25mm Dia with 8mm rod size 75 Supply and fixing of following size sprinkler hanger with threaded rod , hanging rod , fasteners Rubber lining zinc plated suitable to hang follwing size sprinkler pipe as required.32mm Dia with 8mm rod size 76 Supply and fixing of following size sprinkler hanger with threaded rod , hanging rod , fasteners Rubber lining zinc plated suitable to hang follwing size sprinkler pipe as required.40mm Dia with 8mm rod size 77 Supply and fixing of following size sprinkler hanger with threaded rod , hanging rod , fasteners Rubber lining zinc plated suitable to hang follwing size sprinkler pipe as required.50mm Dia with 8mm rod size 78 Supply and fixing of following size sprinkler hanger with threaded rod , hanging rod , fasteners Rubber lining zinc plated suitable to hang follwing size sprinkler pipe as required.65mm Dia with 10mm rod size 79 Supply and fixing of following size sprinkler hanger with threaded rod , hanging rod , fasteners Rubber lining zinc plated suitable to hang follwing size sprinkler pipe as required.80mm Dia with 12mm rod size 80 Supply and fixing of following size sprinkler hanger with threaded rod , hanging rod , fasteners Rubber lining zinc plated suitable to hang follwing size sprinkler pipe as required.100mm Dia with 12mm rod size 81 Supply and fixing of following size sprinkler hanger with threaded rod , hanging rod , fasteners Rubber lining zinc plated suitable to hang follwing size sprinkler pipe as required.150mm Dia with 16mm rod size 82 4 w inlet breeching C.I. Body having 04 way gunmetal 63 mm male instantaneous conforming to IS:903, fitted with non return valves, flange outlet 280m OD, 240mm PCD, eight holes of 22 mm dia complete with gunmetal 25mm size. 83 Hose reel drum of swinging type with 19mm dia Rubber braided hose of 30m length with Ball valve and Shut off nozzle, complete. 84 Fire duct Shutter fabricated out ofM.S. sheet and frame, door shall be 600mm x 1200 mmx2100mm min. and fixed with 4 mm thick Glass, suitable Rubber beading and Locking arrangement. Quoted rate shall be includes all fasteners etc, and complete shutter shall be powder coated finish of red colour both inside and out side. 85 M.S. Hose cabinet stand/ wall mounted type fabricated out of M.S. sheet of 16 swg. with glass fronted ( 4mm thick glass with rubber beading) door and size of the cabinet shall be 600mm x 750 mm x 250 mm. Quoted rate shall be includes suitable stand for mounting, all fasteners etc, and cabinet shall be powder coated finish of red colour both inside and outside. 86 Supplying and fixing of approved make 25mm dia. automatic air release valve with unions etc. complete. 87 Supplying, installing, testing and commissioning of Gun metal chrome finished Ball valveswith fittings of screwed end type.25mm nominal dia. 88 Supplying, installing, testing and commissioning ofM.S. puddle flenge complete with all accessories.150mm nominal dia 89 Supplying, installing, testing and commissioning of Gun metal chrome finished Ball valveswith fittings of screwed end type.25 mm nominal dia ( Air vessel tank and Pressure switch manifold) 90 Exhuast pipe for Diesel engine of 100 mm dia M.S. Medium grade with mineral wool insulation with aluminum sheet. The quoted rate shall include 100 mm diameter MS pipe medium grade conforming to IS 1239 Part-1 and mineral wool insulation with aluminum sheeting and Pipe supports also. 91 Supplying and erecting of Pre fabricated M.S structural steel supports such as angle, Channel, Plate etc. conforming to relevant IS standards for supporting suction and delivery pipe of each fire pump and delivery pipe to hydrant and sprinkler pipe within the pump room. 92 Supply and installation testing and commissioning of Pressure gauges of suitable range (0-16 bar), 100 mm diameter dial for pumpsets completes with necessary Ball valves, siphon, Fittings like unions / colors / reducers etc. 93 Providing, fixing, jointing and testing uPVC mineral filled floor traps of self cleansing design with water seal not less than 50 mm., with or without vent, jointing with push fit rubber ring socket fittings complete, cutting chases / hole in floors / slabs and bringing the same in proper condition and shape after placing the trap in right position in case of suspended / open plumbing or setting the trap in 1:2:4 CC in case of concealed plumbing , etc. complete, as required. The trap shall be of following sizes: Temporary airtight PVC cover to be provided to prevent dirtentry..(Make..Supreme/Astral/Ashirvad) 94 `Providing and fixing health faucet with 1.2 m long flexible tube and wall hook including all fittings.(Make..Jaguar/Woyo/Hindware)` 95 `Providing and fixing water tank filling alram system complete in all respect as per entire satisfaction of engineer-in-charge(Make..Anchor/Goldmedal/SSM Aquamax)` 96 Providing and fixing25 mm dia motorize valve ..(Make..Leader /Honeywell/Zoloto) 97 Providing and Fixing of stainless steel grating with rim of approved design including setting in floor with cement mortar. (For Floor Trap/Floor Drain)..(Make..Camry /Chilly/Neer)125 mm dia 98 INTERNAL SOIL, WASTE and VERTICAL RAIN WATER PIPEProviding and fixinguPVC pipe conforming to IS:4985 (10 kg/sq cm) including all fittings, This includes jointing of pipes and fittings with one step solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge and as per layout.(Make..Supreme/Astral/Ashirvad)40 mm 99 Providing and fixinguPVC pipe conforming to IS:4985 (10 kg/sq cm) including all fittings, This includes jointing of pipes and fittings with one step solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge and as per layout.(Make..Supreme/Astral/Ashirvad)50 mm 100 Providing and fixinguPVC pipe conforming to IS:4985 (10 kg/sq cm) including all fittings, This includes jointing of pipes and fittings with one step solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge and as per layout.(Make..Supreme/Astral/Ashirvad)110 mm,,,, 101 Providing and fixinguPVC pipe conforming to IS:4985 (10 kg/sq cm) including all fittings, This includes jointing of pipes and fittings with one step solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge and as per layout.(Make..Supreme/Astral/Ashirvad)150 mm 102 Providing and fixinguPVC pipe conforming to IS:4985 (10 kg/sq cm) including all fittings, This includes jointing of pipes and fittings with one step solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge and as per layout.(Make..Supreme/Astral/Ashirvad)200 mm 103 Providing and fixing floor drainfixed with cement mortar complete in all respect...(Make..Supreme/Astral/Ashirvad)110 x 50 104 Providing and fixing 100 mm dia uPVC hopper approximately 300 mm long with maximum 3 inlets 32, 50 or 63 mm size fabricated from uPVC heavy duty pipes , sockets, fixed to UPVC trap withjoint and set in cement concrete mix 1:2:4 complete as per standarddrawing..(Make..Supreme/Astral/Ashirvad)100 mm dia 105 Providing and fixing 15mm flexible pipe 15 mm dia..(Make..Supreme/Astral/Ashirvad) 106 Providing and fixing water cooler of 2 kl in silver colour of stainless steel material complete in all respect as per the direction of engineer-in-charge ..(Make..Bluestar/Orient electric/Bajaj) 107 1`Supply, Installation, testing and Commissioningof modular type Variable Refrigerant Flow/ Variable Refrigerant Volume aircooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R407c/R410a/EQUIVALENT Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V plus /-10%, 3Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required.- The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5...(MakeDaikin/Bluestar/Voltas/Mitsubishi)`1.1 NS-1 34 HP 108 `Supply, Installation, testing and Commissioningof modular type Variable Refrigerant Flow/ Variable Refrigerant Volume aircooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R407c/R410a/EQUIVALENT Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V plus /-10%, 3Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required.- The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5...(MakeDaikin/Bluestar/Voltas/Mitsubishi)`36 HP 109 `Supply, Installation, testing and Commissioningof modular type Variable Refrigerant Flow/ Variable Refrigerant Volume aircooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R407c/R410a/EQUIVALENT Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V plus /-10%, 3Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required.- The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5...(MakeDaikin/Bluestar/Voltas/Mitsubishi)`18 HP 110 `Supply, Installation, testing and Commissioningof modular type Variable Refrigerant Flow/ Variable Refrigerant Volume aircooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R407c/R410a/EQUIVALENT Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V plus /-10%, 3Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required.- The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5...(MakeDaikin/Bluestar/Voltas/Mitsubishi)`36 HP. 111 `Supply, Installation, testing and Commissioningof modular type Variable Refrigerant Flow/ Variable Refrigerant Volume aircooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R407c/R410a/EQUIVALENT Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V plus /-10%, 3Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required.- The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5...(MakeDaikin/Bluestar/Voltas/Mitsubishi)`32 HP 112 Supply, installation, testing and commissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cordless/corded remote control etc., suitable for operation on single phase 230V±10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 DegreeC DB and 19 DegreeC WB temperature.(MakeDaikin/Bluestar/Voltas/Mitsubishi)0.8 TR 113 Supply, installation, testing and commissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cordless/corded remote control etc., suitable for operation on single phase 230V±10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 DegreeC DB and 19 DegreeC WB temperature.(MakeDaikin/Bluestar/Voltas/Mitsubishi)1.3 TR 114 Supply, installation, testing and commissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cordless/corded remote control etc., suitable for operation on single phase 230V±10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 DegreeC DB and 19 DegreeC WB temperature.(MakeDaikin/Bluestar/Voltas/Mitsubishi)1.6 TR 115 Supply, installation, testing and commissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cordless/corded remote control etc., suitable for operation on single phase 230V±10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 DegreeC DB and 19 DegreeC WB temperature.(MakeDaikin/Bluestar/Voltas/Mitsubishi)2.0 TR 116 Supply, installation, testing and commissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cordless/corded remote control etc., suitable for operation on single phase 230V±10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 DegreeC DB and 19 DegreeC WB temperature.(MakeDaikin/Bluestar/Voltas/Mitsubishi)2.6 TR 117 Supply, installation, testing and commissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cordless/corded remote control etc., suitable for operation on single phase 230V±10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 DegreeC DB and 19 DegreeC WB temperature.(MakeDaikin/Bluestar/Voltas/Mitsubishi)3.2 TR 118 `Supply, installation, testing and commissioning of following minimum capacity and external static pressure VRF/VRV ceiling mounted ductable type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, corded remote control, outer cabinet, vibrationisolators, drain pan, other necessary supports etc., suitable for operation on single phase AC supply 230V±10%, 50Hz complete as required. The unit shall have automatic force shutdown provision in case of fire on receiveing signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.(MakeDaikin/Bluestar/Voltas/Mitsubishi)`6.4 TR 119 Supply, installation, testing and commissioning of following minimum capacity VRV/VRF Highwall type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil ection with DX copper coil, electronic expansion valve, outer cabinet, cordless remote control, drain pan, necessary accessories etc., suitable for operation on 230V±10%, 50Hz, single phase AC supply, complete as required. The unit shall have automatic force shutdown provision in caseof fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature...(MakeDaikin/Bluestar/Voltas/Mitsubishi)1.0 TR 120 Supply, installation, testing and commissioning of following minimum capacity VRV/VRF Highwall type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil ection with DX copper coil, electronic expansion valve, outer cabinet, cordless remote control, drain pan, necessary accessories etc., suitable for operation on 230V±10%, 50Hz, single phase AC supply, complete as required. The unit shall have automatic force shutdown provision in caseof fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature...(MakeDaikin/Bluestar/Voltas/Mitsubishi)AHU KIT..(Make Zeco/Edgetech/Avantec) 121 `Supply, Installation, testing and Commissioning of following capacities of ducted inline fans as per specification and complete with suitable 1 phase Motor with 3 speed control, bird screen etc. and required for complete installation include Lifting, shifting, assemblling and positioning of the equipment comprising of the following and complete as per specification/drawingsand as directed by Engineer InCharge.The fan casing shall be made of galvanised steel casing with min. 200 GSM zinc coating.The Fan must be selected for minimum power consuption and Maximum efficiancy at respective duty point. Max. noise level shall be 65 dBA at 3.0 meter...(Make Kruger/Caryaire/Airflow)`250 CFM @ 8 mmWG ESP 122 `Supply, Installation, testing and Commissioning of following capacities of ducted inline fans as per specification and complete with suitable 1 phase Motor with 3 speed control, bird screen etc. and required for complete installation include Lifting, shifting, assemblling and positioning of the equipment comprising of the following and complete as per specification/drawingsand as directed by Engineer InCharge.The fan casing shall be made of galvanised steel casing with min. 200 GSM zinc coating.The Fan must be selected for minimum power consuption and Maximum efficiancy at respective duty point. Max. noise level shall be 65 dBA at 3.0 meter...(Make Kruger/Caryaire/Airflow)`300 CFM @ 15 mmWG ESP 123 `Supply, Installation, testing and Commissioning of following capacities of ducted inline fans as per specification and complete with suitable 1 phase Motor with 3 speed control, bird screen etc. and required for complete installation include Lifting, shifting, assemblling and positioning of the equipment comprising of the following and complete as per specification/drawingsand as directed by Engineer InCharge.The fan casing shall be made of galvanised steel casing with min. 200 GSM zinc coating.The Fan must be selected for minimum power consuption and Maximum efficiancy at respective duty point. Max. noise level shall be 65 dBA at 3.0 meter...(Make Kruger/Caryaire/Airflow)`650 CFM @ 8 mmWG ESP 124 Y JOINT..(Make Kruger/Caryaire/Airflow) 125 `Supply and laying, testing and commissioning of following sizes of Copper conductor control cables through conduit on existing tray including fixing clamps and proper connections to equipments etc. complete as required. As per specification/drawingsand as directed by Engineer In Charge.....(Make Paramount/RR Kabel/KEI`2C x 1.5 sq.mm. 126 Supplying and fixing of powder coated extruded aluminium supply eye ball diffuser with aluminium volume control dampers as per specifications...(Make Airflow/Caryaire/Metal Joint 127 `SUPPLYING , INSTALLATION , TESTING and COMMISIONING OF 13 PASSENGER LIFTS HAVING 4 STOPS with all opening on the same sideFOLLOWING SPECIFICATIONSPassenger Elevator (Not less than 884 kg) elevator having speed of 1 meter per second Serving different floors in the existing lift shaft of size 1.8m x2.3mhaving stainless steel doo finish with a car dimension of 1400x1450x2300mm having central opening with door opening of 900x2100mm with DC door operator with monochrome LCD-Blue Background and white font. Complete in all respect as per Satisfaction of Engineer-in-charge.(Make: OTISJohnson,Schindler)` 128 Providing and installation of RFID based Automation Solution for Library Management System. Complete in all respect as per Satisfaction of Engineer-in-charge...(Make: Rapid Radio Solutions , Vast Electronic and Services , Rockwell Automation) 129 Providing and fixing of MUNSHIPREMCHAND LIBRARY in Acrylic Letters with light of 24` Height with power Supply and Warrenty of 2 yearswith fittings complete with all respect. 130 Providing and fixing ofLIBRARY in Acrylic Letters with light of 24` Height with power Supply and Warrenty of 2 yearswith fittings complete with all respect. 131 Providing and fixing of floor vinyl strickring 3m pasting on floorcomplete in all respect as per the entire satisfaction of engineer in-charge 132 Providing and fixing of 8mm Toughened Lacquered glasscomplete in all respect up to the entire satisfaction of Engineer-in-charge of the work. 133 Providing and fixing of carpet flooring of 5MM thick with installation of 504 grey colour complete in all respect up to the entire satisfaction of Engineer-in-charge of the work. 134 Providing and fixing of Slim profile (25 MM X45MM) with monish black powder coating (Akzonobel 0.5 micron) with 10mm saint Gobine glass added with Gobian bar (16mmx16mm) black colour and milky film on clear glass with machine set ofGlass Max with warrenty of 5 years. complete in all respect up to the entire satisfaction of Engineer-in-charge of the work. 135 Providing and fixing of terracota bricks of size 75x230x10mm as per design complete in all respect up to the entire satisfaction of Engineer-in-charge of the work. 136 Providing and fixing of signages of toilet of size 300x450mm as per design complete in all respect up to the entire satisfaction of Engineer-in-charge of the work. 137 Providing and fixing of signages of department names of size 600x1200mm as per design complete in all respect up to the entire satisfaction of Engineer-in-charge of the work. 138 Providing and fixing of signages of fire exitnames of size 800x300mm as per design complete in all respect up to the entire satisfaction of Engineer-in-charge of the work. 139 Providing and fixing of signages of drinking water / liftnames of size 300x300mm as per design complete in all respect up to the entire satisfaction of Engineer-in-charge of the work. 140 17.1.1 Supplying, installation, testing and commissioning of heat detector operating at 54°C/57°C with rate of rise cum fixed tempreature (dual thermistor) type with mounting base complete with all connection etc. as required. 141 17.1.2 Supplying, installation, testing and commissioning of smoke detector with built-in LED and mounting base complete with all connections etc. as required. 142 17.1.3 Supplying, installation, testing and commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain and hammer assembly complete with glass and push button etc. as required. 143 17.1.5 Supplying, installation, testing and commissioning response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required. 144 17.1.6 Supplying, installation, testing and commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate and suitable for operation with amplifier i/c line matching transformer etc. complete as required. 145 17.1.8 Supplying, installation, testing and commissioning talk back slave station in surface/recess suitable for operation on simplex mode complete with P.T.T. knob and speaker/microphone enclosed in a M.S. (16 SWG)/ ABS box with break glass in front etc. complete as required. 146 17.1.9 Supplying, installation, testing and commissioning fire alarm sounder with facility to make announcement, mounted in A.B.S. box with hinged cover plate and suitable for operation with amplifier i/c line matching transformer etc. complete as required.6 Zone 147 17.1.11 Supplying, installation, testing and commissioning of main control and indicating panel made out of 16 SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections, interconnections etc. complete as required. 148 17.5.1 Supplying and laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring and LSZH outer sheath complete as required. 149 `Supplying, installation, testing and commissioning ofElectric driven Main Fire Pump suitable for automaticoperation and consisting of following, complete in allrespects, as required : (a) Horizontal type, multistage, centrifugal, split casingpump of cast iron body and bronze impeller with stainlesssteel shaft, mechanical seal conforming to IS 1520.(b) Suitable HP Squirrel cage induction motor, TEFC,synchronous speed 1500 RPM, suitable for operationon 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-`F` insulation, conforming to IS-325. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads...2280 lpm at 70 m Head ... 2280 lpm at 70 m Head` 150 `Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel DrivenPump) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft,mechanical seal conforming to IS 1520.Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thickaluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office redcolour etc. as required.M.S fabricated, common base plate, coupling, couplingguard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads....1620 lpm at 70 m Head` 151 `Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft,mechanical seal conforming to IS : 1520. Suitable HP squirell cage induction motor TEFC typesuitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure,horizontal foot mounted type with Class-`F` insulation, conforming to IS : 325. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads...180 lpm at 70 m Head` 152 `Fabrication, supply, Insallation testing and commissioning of Electrical control panel of cubical construction, floormounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors,dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter connection with suitable size copper conductor cable/solid copper strip, having switchgears andaccessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect,suitable for main fire pump, pressurisation pump and diesel pump set complete as per CPWD specificationwith following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required :` 153 `Supplying, fixing, testing and commissioning of butterflyvalve of PN 1.6 rating with bronze/gunmetal seat duly ISImarked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :....100mm nominal dia` 154 `Supplying, fixing, testing and commissioning of butterflyvalve of PN 1.6 rating with bronze/gunmetal seat duly ISImarked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :....150mm nominal dia` 155 Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange...200mm dia. 156 Providing and fixing of pressure switch in M.S. pipe line including connection etc. as required. 157 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shadev as required. 158 `Providing, fixing, testing and commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases,strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required :..150mm dia. ` 159 `Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS 1239including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on thewall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :.200mm nominal dia ` 160 `Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS 1239including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on thewall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :.150mm nominal dia ` 161 `Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS 1239including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on thewall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :.100mm nominal dia ` 162 `Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steelcoupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blankGunmetal/Stainless Steel cap and chain as required :..Single headed Gunmetal` 163 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :..Gun Metal 164 Supplying and fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneousconnection to interconnect hose pipe coupling as required :...Gun metal 165 `Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS 1239including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on thewall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :.80mm nominal dia ` 166 `Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS 1239including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on thewall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :.65mm nominal dia ` 167 `Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS 1239including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on thewall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :.50mm nominal dia ` 168 `Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS 1239including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on thewall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :.40mm nominal dia ` 169 `Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS 1239including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on thewall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :.32mm nominal dia ` 170 `Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS 1239including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on thewall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :.25mm nominal dia ` 171 Providing, fixing, testing and commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :...Pendent Sprinkler 172 `Supplying, installation, testing and commissioning of sprinkler flexible pipe (UL Listed) of stainless steelcomplete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required...700mm` 173 Providing and fixing flow switch in following sizes M.S. pipe including connection etc as required..150mm Dia 174 Supply, Installation, testing and commissioning including vaccumiazation andNitrogen testing of following nominal sizes of soft/ hard drawn copper refrigerantpiping for DX/VRV/VRF system, complete with fittings, with suitable adjustablering type hanger supports, jointing/ brazing including accessories, insulated withXPLE Class-O tubular insulation/ with Class-O closed cell elastometric nitrilerubber tubular sleeves sections of specified thickness as given below for Suctionand Liquid lines, all accessories as per specifications etc. as required. 175 Supply, Installation, testing and commissioning including vocalization andNitrogen testing of following nominal sizes of soft/ hard drawn copper refrigerantpiping for DX/VRV/VRF system, complete with fittings, with suitable adjustablering type hanger supports, jointing/ brazing including accessories, insulated withXPLE Class-O tubular insulation/ with Class-O closed cell elastomeric nitrilerubber tubular sleeves sections of specified thickness as given below for Suctionand Liquid lines, all accessories as per specifications etc. as required. 9.5mm dia 176 Supply, Installation, testing and commissioning including vocalization and Nitrogen testing of following nominal sizes of soft/ hard drawn copper refrigerant piping for DX/VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/ brazing including accessories, insulated with XPLE Class-O tubular insulation/ with Class-O closed cell elastomeric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required. 12.7 mm dia 177 Supply, Installation, testing and commissioning including vaccumiazation andNitrogen testing of following nominal sizes of soft/ hard drawn copper refrigerantpiping for DX/VRV/VRF system, complete with fittings, with suitable adjustablering type hanger supports, jointing/ brazing including accessories, insulated withXPLE Class-O tubular insulation/ with Class-O closed cell elastometric nitrilerubber tubular sleeves sections of specified thickness as given below for Suctionand Liquid lines, all accessories as per specifications etc. as required 15.86 mm diameter 178 Supply, Installation, testing and commissioning including vaccumiazation andNitrogen testing of following nominal sizes of soft/ hard drawn copper refrigerantpiping for DX/VRV/VRF system, complete with fittings, with suitable adjustablering type hanger supports, jointing/ brazing including accessories, insulated withXPLE Class-O tubular insulation/ with Class-O closed cell elastometric nitrilerubber tubular sleeves sections of specified thickness as given below for Suctionand Liquid lines, all accessories as per specifications etc. as required19 MM DIA 179 Supply, Installation, testing and commissioning including vaccumiazation andNitrogen testing of following nominal sizes of soft/ hard drawn copper refrigerantpiping for DX/VRV/VRF system, complete with fittings, with suitable adjustablering type hanger supports, jointing/ brazing including accessories, insulated withXPLE Class-O tubular insulation/ with Class-O closed cell elastometric nitrilerubber tubular sleeves sections of specified thickness as given below for Suctionand Liquid lines, all accessories as per specifications etc. as required 22.2 mm dia 180 Supply, Installation, testing and commissioning including vaccumiazation andNitrogen testing of following nominal sizes of soft/ hard drawn copper refrigerantpiping for DX/VRV/VRF system, complete with fittings, with suitable adjustablering type hanger supports, jointing/ brazing including accessories, insulated withXPLE Class-O tubular insulation/ with Class-O closed cell elastometric nitrilerubber tubular sleeves sections of specified thickness as given below for Suctionand Liquid lines, all accessories as per specifications etc. as required.25.4 MM DIA 181 Supply, Installation, testing and commissioning including vaccumiazation andNitrogen testing of following nominal sizes of soft/ hard drawn copper refrigerantpiping for DX/VRV/VRF system, complete with fittings, with suitable adjustablering type hanger supports, jointing/ brazing including accessories, insulated withXPLE Class-O tubular insulation/ with Class-O closed cell elastometric nitrilerubber tubular sleeves sections of specified thickness as given below for Suctionand Liquid lines, all accessories as per specifications etc. as required : 25.58mm diameter 182 Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/ hard drawn copper refrigerant piping for DX/VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/ brazing including accessories, insulated with XPLE Class-O tubular insulation/ with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required 31.8 mm dia 183 Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/ hard drawn copper refrigerant piping for DX/VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/ brazing including accessories, insulated with XPLE Class-O tubular insulation/ with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required 34.9 mm dia 184 Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/ hard drawn copper refrigerant piping for DX/VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/ brazing including accessories, insulated with XPLE Class-O tubular insulation/ with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required 38.1 mm dia 185 Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/ hard drawn copper refrigerant piping for DX/VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/ brazing including accessories, insulated with XPLE Class-O tubular insulation/ with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required 41.3 mm dia 186 Supplying, installation, testing and commissioning of duct damper complete withneoprene gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications... 187 Supplying and applying of following thickness duly laminated foil of mat finish closed cell Nitrile Rubber (Class O) thermal insulation on ducts after applying suitable adhesive. The joint shall be sealed with 50mm wide and 3mm thick self adhisive nitrile rubber tape insulation completer as per specs and as required.9 mm thick 188 Supply and fixing of acoustic lining of supply air duct initial minimum 3mtr length from each AHU / TFA using 25 mm thick resin bonded glass wool having density of 32 kg/m³, with 25 mm X 25 mm GI secton of 1.25 mm thick at 600 mm centre to centre covered reinforced plastic tissue paper and 0.5 mm thick perforated al. sheet fixed to inside surface of duct with cadmium plated nuts, bolts, stick pins, CPRX compound etc. complete as required. 189 Supply, installation, testing and commissioning of factory built floor mounted DXtype double skin type horizontal air handling unit made of 25mm thick panelsconsisting of pre plasticised G.I. casing of thickness 0.8mm outside layer and0.8mm inside layer with PUF insulation factory injected between them, thermalbreak profile complete with blower section with blower suitable for static pressureas required, min 2 bend GSS/PVC eliminators, cooling coil section withaluminium finned copper tubes (tubes thickness not less than 0.5 mm) coolingcoil 8 RD, filter section with washable synthetic air prefilter, belt drive packagewith TEFC drive motor of eff class IE3 suitable for 415 ± 10% volts, 50Hz, 3 PhaseAC supply suitably designed for VFD, drain connections, 18G SS drain pan with19mm nitrile rubber insulation, necessary vibration isolation arrangement etc.complete as per specification and following capacities. 190 Providing and fixing customize Wisteria Feather Paper Wall coveringin non-woven paper having width of 108 inches of 260 GSM as per design complete in all respect as per the entire satisfaction of engineer in-charge (Make: Nilaya , Ekvin Decor, Jaypore) 191 Providing and fixing of wooden polymer composite panel and WPC Louvers of size 160 x 2900 x 8.5mm as per design complete in all respect as per the entire satisfaction of engineer in-charge(Make: Alstone , Fairflow , Duraflo) 192 Providing and fixing 50mm Wooden Blinds with single cord operator complete with all respect.. 193 Providing and fixing of grafity on wall as per design complete with all respect as per the direction of engineer-in-charge 194 `Providing and Fixing of Envirotech Systems Acoustical Sound Suspenders™ made of Acoboard™ and Woodperf™Acoustic Panels for achieving the best NRC Value up to 0.90. Size of the Acoustical Sound Suspenders™1200*300*30mm. Construction details are as follows 9mm thick Acoboard fixed over 12mm thick Woodperf Acoustic Panels both the sides with rigid fixation. Design of the Acoustical Sound Suspenders as per the size (1200*1200*30mm)with Top and bottom side flat. The Acoustical Sound Suspenders™ marked with hanging arrangement on the rear sides, each Clouds having distancing from each Clouds as per the design intended to the architect. The Suspenders to besuspended over required accessories loike Uni strut channel using the locking Clip tied by Thread rod or Hanger Wire kit, cable finishing hook. Acoboard and Woodperf Panels are Certified by GRIHA V.2019 criterion: 11, GRIHA V.2015 criterion: 11 and GRIHA V. 3.1 criterion: 29. Installation of the Sound Suspenders as per the instruction lay Down By the manufacturer as per design complete with all respect . as perthe entire satisfaction of engineer in-charge ` 195 Providing and fixing of 6mm Toughened glass comply with the requirement of BS EN 572 parts 1,2 and3 or ASTM C1036 assessed for optical and visual faults as described in BS EN 572-2. Spot faults to be no worsethan category C. There will be no linear /extended faults. Optical faults to be within the limits set in BS EN 572-2 of model no. ET 150 Toughened glass complete in all respect up to the entire satisfaction of Engineer-in-charge of the work. 196 Supplying and fixing of powder coated extruded aluminum door transfer grilles without aluminum volume control dampers as per specifications. 197 Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS 1239including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on thewall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of requiredshade complete as required :.100 mm nominal dia 198 Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS 1239including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on thewall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of requiredshade complete as required :.150 mm nominal dia 199 Supply, installation, testing and commissioning of 27` All-in-One Desktop-computers 13th Gen Intel® Core™ i7, Windows 11, microprocessor, 16 GB RAM, 1 TB SSD, Windows latestembedded OS and SQL Data Base, serial Interface port,USB Ports, compatible display card,keyboard, Mouse. (Make :- Dell / HP/LENOVO) 200 Providing and installation of Efficiency Engineered - A3 Refill Ink Tank Printer with A3,A4, A5 tray with Wireless and Ethernet Connectivity, Automatic 2-sided Colour Print,Professionally Designed for Fast Print Speeds, Low Cost High Photo Quality with UltraHigh Yield Ink Bottles, Wi-Fi Direct, Mobile and USB Print Complete in all respect as perSatisfaction of Engineer-in-charge..(Make: HP, Brother, Canon) 201 Providing and installation of Laserjet A4 Black and White Printer with scanner ,wifidirect. Complete in all respect as per Satisfaction of Engineer-in-charge...(Make: HP,Brother, Canon) 202 Providing and installation of Laserjet A4 Black and White Printer with scanner ,wifidirect,fax with auto front and back paper print technologyComplete in all respect as perSatisfaction of Engineer-in-charge...(Make: HP, Brother, Canon) 203 Deduct - Credit of half brick bats / brick malba 204 Deduct - Recovery Of 80mm Old Interlocking Paver Blocks.
Contract Date : 25 Oct, 2025   |   Contract Value : 8.06 Crore
BRR : 9857154 Tender For Provision Of Or Md Accommodation At Clement Town Dehradun.; 2 Construction ofORs Md Accn (G+6 storey),(RCC Framed Structure) ,including RCC over head tank of capacity 25KLoverterrace, with permanent specification all as shown on drawings and as specified. 3 SCHEDULE A PART II-A (Internal Water Supply) for details refer Sch A in pdf folder 4 SCHEDULE A PART II-B (Internal Water Supply) 5 S&F Brass Chromium Plated Wall Mixerfor mixing hot and cold waterwith L bend including shower of size 125 mm and shower arm , screwed for iron pipe suitable for 15 mm bore pipes complete all specified and directed. 6 S&F Brass Chromium Plated Central hole wash basin Mixer fancy type with or without lettered Hot or Cold with long screwed shanks and fly nut capstan head screwed for iron pipe suitable for 15 mm bore pipes complete all specified and directed. 7 S&F Brass Chromium Plated Angle Valve, fancy typescrewed for iron pipe suitable for 15 mm bore pipes complete all specified and directed. 8 S&F Health faucet with hose & hook ( complete set) fixed to angle / stop cock 15 mm dia complete all specified and directed. 9 S&F 15 mm bore CP pillar tap fancy type screwed down for iron pipe complete all specified and directed. 10 S&F 15 mm bore brass chromium platedsink mixer fancy type with swinging spout (wall mounted type) for mixing hot and cold water screwed downfor iron pipe complete all as specifed and directed 11 SCHEDULE A PART III-A (Internal Electrification) for details refer Sch A in pdf folder 12 SCHEDULE A PART III-B (Internal Electrification) 13 M & L forpoint wiring using 1.50 sqmm size, PVC insulated, unsheathed 1100 volts grade, IS-694 single core multi-stranded (FRLS-H) copper conductor cable in proper colour coding drawn into and including non metallic rigid PVC conduit medium grade (not less than 20 mm dia) with and including its all necessary fittings and accessories fixed concealed, sunk cast iron or 1.6 mm thick pressed modular steel terminal box for mounting fittings i.e, modularswitch / socketsincl cover plate with frameincluding one continuous run of PVC insulated (green colour) 1.50 sqmm size stranded FRLS-H copper conductor cable as in earth wire and connecting all metal parts to common earth dolly inclcutting and chases pinning in for concealed conduit wiring and making good of disturbed surface complete all as specified and directed for the following: - 14 Note: (i) Also includes inverter wiringwith one run of inverter wire 1.5 sqmm all alongwith circuit also included. (ii) All items used should be ISI marked. (iii) Cutting chases for concealed type point wiring including making good the same with plaster/putty is deemed to be included in quoted rate by the contractor. (iv) Accessories modular metal boxes, cover plate inner & outer is also deemed to be included in quoted rate. 15 (a) One light point/ bulb/ security light /bell buzzer/ ceiling fan/Exhaust fan point controlled by one-one way switch. 16 (b) One three pin 5 Amp socket on same board with other switches. 17 (c) One three pin 5 Amp socket on independent board 18 (d) All as per item No 5.01 above but for two way wiring 19 (e) All as per item No 5.01 above but point wiring with cable 2.50 Sq mm size, with earth continuity conductor of size 2.50 Sq mm. 20 All as per item No- 5.01 above but point wiring with cable 4.0 Sq mm size, with earth continuity conductor of size 4.0 Sq mm. 21 Supply & fixing decorative wall mounted LED tube light 1 x 20 watt with polycarbonate housing and integrated electronic driver with all acessories and fixing materialcomplete all as specified and directed. 22 Supply & fix decorativeLED tube light 1 x 10 watt wall mounted with extruded polycarbonate, integrated lamp & driver with opel diffuser and decorative end plates complete with all acessories and fixing materialcomplete all as specified and directed. 23 Supply & fix LED lamp 9 watt with suitable for batten / angular holder complete all as specified and directed. 24 Supply and fixing Vertical Loadline sheet metal enclosure double door, Triple pole and neutral (TP&N vertical loadline) AC, 415 volts, 08 way, with 200Amps rated copper bus bar and IP - 54 & IK 09 protection, with the inbuilt provison forfixing of 1 No MCCB 160 Amps Capacity and 24 Nos MCBs inside of DB, with metal door and flush to wall including grouting and cutting in existingwall and making good disturbed surfacewith two coats of white / colour washing / distempering etc to match the existing complete all as specified and directed. Note : MCCB and MCBs shall be provided inside the verticle DBs alongwith suitable size of copper wiring. 25 Supply and fixing BLDC Ceiling fan complete with blades, down rods, electronic fan regulator and accessories 230 Volts, 1200 mm sweep,min air delivery 210 CFMfive star rated with BLDC motor, super energy efficient, including provision of flexible cable 3 core of suitable size from ceiling rose to fancomplete all as specified and directed. 26 Supply and fixinglight duty Exhaust fan 300 mm sweep metal body with sturdy steel bird cage,double ball bearing and heavy duty motor copper winding, metal blades and fixing accessories 230 Volt, 28 Watt and including making hole of suitable size in the wall, plastering the surface making good damaged portion with plaster in CM 1:4 incl recolouring complete all as specified and directed. 27 Supply and fixing light duty Exhaust fan 230 mm sweepmade of sturdy engineering plastic complete with louvers shutter, voltage 230 V, 50 Hz, Rpm 1200, copper windingand fixing accessories 230 Volt and including making hole of suitable size in the wall, plastering the surface making good damaged portion with plaster in CM 1:4 incl recolouring complete all as specified and directed. 28 SCHEDULE A PART IV (Site Clearance and Earthwork) for details refer pdf folder 29 SCHEDULE A PART V (Road, Path and Hardatanding) for details refer pdf folder 30 SCHEDULE A PART VI A (Sewage Disposal) for details refer pdf folder 31 SCHEDULE A PART VI B (Sewage Disposal) 32 M & L for construction of septic tank 100 users withclass B brick masonry wall, PCC in foundation floor, M 30 Design Mix RCC over slab including sludge chamber, CI vent pipe, CI cowl, inlet and out let pipe, RCC baffle wall and all necessary excavation and earth work complete all as specified , shown in TD drawing No 217 sheet No 1/7 to 7/7as directed. 33 M & L for Soakage wells comprising of excavation, in any type of soil, foundation in PCC 1:3:6 type C2 , walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.80 M dia X 3.00 M effective depthall as specified and shown in drawing TD-309, sheet No 1/4 to 4/4 34 SCHEDULE A PART VII (Area Drainage) for details refer pdf folder 35 SCHEDULE A PART VIII (Fencing / Gate/ Compound wall) for details refer pdf folder 36 SCHEDULE A PART IX A(Rain Water Harvesting) for details refer pdf folder 37 SCHEDULE A PART IX B (Rain Water Harvesting) 38 Supply andfilling of sand of size 1.50 mm to 2.00 mm in rain water harvesting pit complete all as specified & directed. 39 Supply andfilling of pea gravel of size 5.0 mm to 10.0 mm in rain water harvesting pit complete all as specified & directed. 40 Supply andfilling of stone grit of size 40.0 mm in rain water harvesting pit complete all as specified & directed. 41 Supply andfilling of brick ballast (half burnt ) in rain water harvesting pit complete all as specified & directed. 42 Boring for rain water harvesting 150 mm diameter boring from level to first water tablecomplete all as specified & directed. 43 SCHEDULE A PART X A (External Water Supply) for details refer pdf folder 44 SCHEDULE A PART X B (External Water Supply) 45 M&Lfor Ductile iron pipe, centrifugally cast spun with socket and spigot ends, class K7 suitable for push on joint (rubber gasket D-jointing), 100mm dia, conforming to IS-8329 (2000), in standard length with cement mortar lining inside the pipe without side zinc coating, laid in trenches complete all as specified and as directed. 46 M&L for road cutting 0.75m width and 1.2m depth for laying and dismantling of DI/GI pipes and making good the disturbed surfaces including returning fillingwith and including and PCC (1:3:6) upto depth 20cm from road surface and removing of soil upto 50m complete all as specified and directed . 47 M&L for construction of masonry Pit of size 750 mm x 750 mm x 750 mm for valves and meterscomplete with MS sheetcover and locking arrangement including brick work using sub classB bricks and 15mm thick rendering in cement mortar 1:4 (internal / external) including two coats of white washing to exposed surfaces including2 coats painting to MS sheet cover with synthetic enamelledpaint over a coat of red oxide primer including necessary earthwork in any type of soil and PCC 1:4:8 type D2 as in foundation all as specified and directed. 48 M&L for construction of masonry Pit of size 900 mm x 900 mm x 900 mm for valves and meterscomplete with MS sheetcover and locking arrangement including brick work using sub classB bricks and 15mm thick rendering in cement mortar 1:4 (internal / external) including two coats of white washing to exposed surfaces including2 coats painting to MS sheet cover with synthetic enamelledpaint over a coat of red oxide primer including necessary earthwork in any type of soil and PCC 1:4:8 type D2 as in foundation all as specified and directed. 49 Supply and fixing Air realese valve cast iron,double rubber ball type,body fabricated with cast iron,including high & low pressure cover,cowl as per IS 210 FG 200 conforming to ISI marked, including bolts, nuts, washer and rubber packing all as specified and directed for size 100mm bore of pipe line complete all as specified and directed. 50 SCHEDULE A PART XI A (EXTERNAL ELECTRIC SUPPLY)for details refer pdf folder 51 SCHEDULE A PART XI B (EXTERNAL ELECTRIC SUPPLY) 52 Supplying, installing, commissioning and testing of transformer outdoor type step down 11/0.433 KV (at no load) with HT 3 phase and LT 3 phase 4 wire AC, 50 Hz, 160 KVA, copper wound, Energy Efficiency Level-III type, with offload changing arrangement on HT side for a variation of secondary voltage +/- 7.5% in steps of +/- 2.5 % including suitable cable entry boxes on LT side and HT Bushing on primary side complete in all respects with standard accessories and fitments confirming to IS-1180 (Part-I & II):2014 as specified and as directed including the following- 53 (a) Earthing terminal and rating diagram plate(b) Air release device(c) Oil filling inlet pipe with plug(d) Drain outlet pipe with brass gate valve with dummy plug(e) Conservator with level gauge(f) Silica gel with breather(g) First oil fill up to the recommended level by the manufacturer with new oil confirming to IS 335(h) Type of connection - Delta/Star(j) Type cooling- ONAN(k) Vector group - DYN 11 54 (l) Type of connecting arrangement - ACSR conductor connection on HT Side and cable connection box on LT Side(m) Provision of thermometer with pocket(n)(o) Oil and winding alarm and trip relay including marshal box(p) Platform of Size 3.0x 3.0 x 1.2m height from ground level with stairs including excavation, PCC 1:5:10 type E2 in foundation, brick work in CM 1:6, PCC 1:2:4 type B1 in coping, plastering 10mm thick in CM 1:6 on brick/concrete surface and on top covered with GI chain link fencing 1.20m high gate of mesh size 50 x 50mm and GI wire dia 3.15mm incl suitable size of angle Iron, nuts & Bolts etc. and deemed included unit rate quoted by contractor against this item of transformer. 55 Supply and erection in truely vertical position steel tubular swaged poles, type 410 SP-55 (11.00 meters long) with cast iron base frame, finial taper plug, bolts, nuts and screws all as specified including factory painted with two coats of black bituminous paint internally through out and externally for embedded portion and making 30 cms wide strips with yellow and black paint at alternatively upto 1.50 metre height and applying two coats of aluminium paint over a coat of red oxide primer on remaining exposed surface after erection , including writing of pole Number complete all as specified and directed by the Engr-in-Charge. Note:(1) All excavation & earth work as involved shall be measured & paid seprately.(2) PCC foundation and Coping as involved shall be measured and paid seprately under respective items. 56 Supply and erection in truely vertical position steel tubular swaged poles, type 410 SP-31 (9.00 meters long) with cast iron base frame, finial taper plug, bolts, nuts and screws all as specified including factory painted with two coats of black bituminous paint internally through out and externally for embedded portion and making 30 cms wide strips with yellow and black paint at alternatively upto 1.50 metre height and applying two coats of aluminium paint over a coat of red oxide primer on remaining exposed surface after erection , including writing of pole number complete all as specified and directed by the Engr-in-Charge. Note:(1) All excavation & earth work as involved shall be measured & paid seprately.(2) PCC foundation and Coping as involved shall be measured and paid seprately under respective items. 57 M & L including testing and commissioning of NATURE Switch for outdoor lighting automation using space grade sensors and an advances micro controller suitable for outdoor use having features Automatic Switching ON at Sunset, Automatic Switching OFF at dawn, No clock setting and time settings wide operating voltage range, High voltage trip and auto reset having specification 415 Volts, 50 Hz, 04 Nos incomer MCBs of suitable ratign with auto and manual arrangement including 03 Nos contactor and suitable rating outgoing MCBs single pole type complete with all connected accessories of rating 12 KW 3 phase, current range 40 Amps all as specified. Make- KAKTIYA ENERGY SYSTEM Model No- SWADEEP-02EC12KWP3P or eqvt 58 Material and Labour for Design, supply, Fabrication, Installation, testing and Commissioning factory made, LT panel board, (SIZE NOT LESS THAN-1200X1200X500 MM, LXWXD) Outdoor type, totally enclosed, dust and vermin proof suitably ventilated, floor mounted, 415 volts, 3 phase and neutral, 50 hz, AC supply system, fully compartmentalised, both side openable, made out of 3.00mm thick CRCA sheet steel, protection of enclosure IP-54 as per IS : 2147 of 1962 with pre-treatment and powder coated of approved colour including suitable frame work / support made out of suitable size of angle iron / flat iron, front opening type with provision for cable entry, 59 with proper ferrule and cable glands, internal wiring with PVC insulated multi stranded copper conductor FRLS cable of adequate size (minimum 1.5 sqmm), including required civil works/anchoring bolts for fixing, PCC foundation etc with and including following all as specified and directed : -a)Busbarchamber :Electrically grade copper shrouded bus bar of capacity 400 Amps for each phase and 400 amps for Neutral andcurrent density 0.8/Sqmmincluding interconnection of all switch gears, fixed on DMC insulators and provision of extension. 60 Note- The panel shall be free standing on angle iron having size 65x65x6 mm and height 900mm long with 04 Legs with base support of MS flat of size 100x100x6 mm complete with following scope of work-INCOMER :(i) MCCB 250Amps, 415Volts, 4 pole 50 Hz, 36 KA with adjustable , thermal magnetic release in built instantaneous protection, Ics = 100%Icu(1 sec) complete all as specified and directed. 01 Nos. (ii) Ammeter 0 to 400 Amps digital type with built in selector switch, CTs of suitable ratio 400/5 amp , 5 VA class 1.0 (set of three) = 01 set. 61 (iii) Voltmeter 0 to 500 volts digital type with built in selector switch = 01 No(iv)AC three phase LT/CToperated multifuctional energy meter of accuracy class-0.5, 3x240 volts 50 Hz, with optical, backlit LCD display, measures and display, trivector energy and load survey, TOD temper detection and lodging power on/off events, instataneous parameter of rating - 5 Amps, with display in absence of power complete - 01 No (v) Phase Indication lamps (RYB), LED type - 01 No (set of three).(vi)MCB SP 6Amps 10 KA,for control protection RYB phase (set of 3)-01 set. 62 Outgoing:Outgoing with one compartment each comparment will consist the following :(i) MCCB 160 amps, 415Volts, 4 pole 50 Hz, 16 KA with adjustable thermal magnetic release, in built instantaneous protection, Ics = 100%Icu(1 sec) complete all as specified and directed- 02 Nos(ii)MCCB 63 amps, 415Volts, 4 pole 50 Hz, 16 KA with adjustable thermal magnetic release, in built instantaneous protection, Ics = 100%Icu(1 sec) complete all as specified and directed- 01 Nos (iii) MCB SP 16 - 20 Amps10 KA- 01 Nos 63 Supply and fixing polycarbonate kiosks box suitable for three phase 415 volts AC supply with 04 Nos Aluminium bus bar rating 63 amps with one NoMCB 16 Amps, SP having size 300X200X150 mm complete including making fixing arrangement on 9 mtr long swaged pole with flat iron clamp including connection from light fitting to junction box with 1.0 sq mm, 3 core wire all as specified and directed by Engr-in-charge. 64 Supply fabricated and fixing street light bracket made out of GI pipe 1.2 mtr long 40/50mm dia medium grade bent to shape including clamps made out of 40 x60 mm flat iron for steel tabular pole, nuts, bolts including painting all as specified 65 Sand cushioning with fine sand to under ground cables in trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable as specified. Note :- Punned thickness shall be measured and paid. 66 SCHEDULE A PART XII A (LIFTS)for details refer pdf folder 67 SCHEDULE A PART XII B (LIFTS) 68 Design, supply, install, testing & commissioning of lift carry 8 passengers , cap 554 kgs, speed 1.5 metre/sec with single speed motor, 415 volts, 3 phase AC 50 Hz supply, conforming to IS-14665 and as amended, suitable to serve G+06 upper floors with AC Variable Voltage & Variable Frequency Drive (VVVF drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set (03 Nos, one each in car, Machine room & near Ground floor landing door)including one fireman switch which will be activated in case of fire incident including wiring and talk back facility complete including cable etc all as specified 69 Design, supply, install, testing & commissioning of lift carry 13 passengers , cap 884 kgs, speed 1.5 metre/sec with single speed motor, 415 volts, 3 phase AC 50 Hz supply, conforming to IS-14665 and as amended, suitable to serve G+06 upper floors with AC Variable Voltage & Variable Frequency Drive (VVVF drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set (03 Nos, one each in car, Machine room & near Ground floor landing door) including one fireman switch which will be activated in case of fire incident including wiring and talk back facility complete including cable etc all as specified 70 Supply & Lay XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 16 sqmm 4 core. 71 Providing manpower & operation of 4 x pessenger lifts at Clement town military station by providing manpower 01 x Un-skilled lift operator per shift in a day for 8 hrs including Sunday & holiday and carrying out minor regular / periodical repairs and regular servicing for upkeep the passenger lift serviceable in all respect, checking of oil levels, thorough checking of lift, make the machinery /equipment dust free, including thorough cleaning up of battery terminals of ARD unit, greasing/oiling of moving parts, leak testing etc all as specified and directed by the Engineer-in-charge. (Note:- (i)The duration of work will be carried out in three shifts from 0600 hrs to 1400 hrs (First Shift), 1400 hrs to 2200 hrs 72 (Second Shift) and 2200 hrs to 0600 hrs ( Third Shift). (ii)The duration of work will be carried out in three shifts of 08 hrs of each shift by deploying the manpower 02 x Un-skilled lift operator in each shift (Total 06 operators in one day) to operate the 04 Nos automatic lift ( 02 x 08 passengers & 02 x 13 Passenger) in high rise towers of G+6 storey). [24 months for DLP & 36 Months after DLP] 73 Comprehensive maintenance of all mechnical & electrical components & conduct a thorough inspection of the fully automatic 04 x passenger lifts ( 02 x 08 passengers & 02 x 13 Passenger) in two high rise tower of G+6 storey) with mechnical & electrical systems, including motor, cables, brakes, control panels & wiring. Identify any signs of wear, drainage or carring out daily check and periodical services of fully automatic electrical lift with power operated door, simplex collective control system with repair / maintenance of unserviceable parts such as bearings, bushes, all type of guide shoes, headers, hangers, door ropes, door cards, car door sills, landing door sills, 74 door locks, control cards and its contacts, hall push buttons and its spares, connector / links, welding of crack/broken and MS parts,kanding operating panel of any size & capacity, repair / maint of u/s damaged door safety edge & sensor mechnical safety locks, megnatic lock of contact, car position indicator & all connected accessories, necessary wiring of hall push button assembly, repair/ mantenance of broken COP/LOP buttons & 75 display including cover, fire alarm, firemen button glass, intercom, alarm/hooters, maintenance of damged hand rail shaft, light / switches , complete with illuminated push button & direction indicator with LPT/LPC card of stainless steel inclusive of harness wiring for laminating of push button of each floors & safe operation of lifts, fixing of loose rail brackets if any, cabin mirror light & minor repair of cabin fan, ensure safe & smooth functioning of lift & complete maintenance of car top, binding of loose wire at control panel & rust painting at car top and door, dewatering of lift well in case of any emergency arise all as directed by Engineer-in-charge. [ 36 Months after DLP] 76 SCHEDULE A PART XIII A (DG SETS)for details refer pdf folder 77 SCHEDULE A PART XIII (DG SETS) 78 Supply ,installation ,commission and testing totally enclosed type (silent operation with canopy,CPC B-IV approved ),static type Diesel Engine driven,Generating set of 40 KVAcapacity confirming to BS-5514/IS -13018:1990(Engine) & IS-13364/IS-4722 (Alternator), 4 wire 50 HZ415 Volts supply under NTP conditions when running at 1500 RPM complete including Engine Alternator mounted on common base plate of rigid fabricated mild steel base frame all as recommended by manufacturer and having following provisions all as specified and directed . 79 The silent canopy shall be as per the Central Pollution Control Board norms . The silensor canopy shall be manufacturerd by the manufacturer of the engine itself . The make and model of generator set to be installed with engine details ,alternator specifications and specification of silensor canopy shall be got approved from GE before order is placed by the contractor to the manufacturer. 80 (A) Alternator:- Alternator shall be of capacity of 40 KVA net out put at work site after considering derating factor as per MSL height and NTP conditions as applicable at power factor .85,AC , 3 phase , 4 wire, AVR system, screen protected . Ball / roller bearing with damp proof copper windings on each pole to base as per IS-13364/IS-4722 complete all as specified . 81 ( B ) Diesel Engine :- Diesel shall be of adequate capacity suitable for above alternator after derating factor as per MSL hight and temperature for work siteand as per relevant IS code having provision of coupling shaft to drive the above Alternator independtly after considering power losses in all the accessories forming part of the set i.e. couplings any type FIP , water cooler, direct injector ( if provided ), fan etc. Engine should be multistage, vertical multi cylinder water cooled, 4 stroke, direct injection cold starting , RPM1500, industrrial type standard accessories complete in all respect including all provisions as recommended by manufacture and following provisions complete all as specified and directed. (Note: DG set will be conforming to notification of Min of Environment date 17 may 2002):- 82 (i) Fly wheel with housing .(ii) Air cleaner dry type(iii) Corrosion resisiters.(iv) fuel filter, Oil filter (v) FIP system including pump injectors solenoid controls , nozzles, govenors etc(vi) Radiiator including water pump with fan (vii) Cylinder with buffers, tail pieces duly insulated with asbestos/ lagging and sufficiently extended to carry exhaust outside theDG Set building. 83 (a) Lead acid battery 12 volts , 90/100AH = 01Nos. initially chargedMake :- Exide/Prestolite/ AMCO ( Maintenance free type)(b) Self Starter.(c)Alternator12 volts DC complete with holding clamp. (d) Start / Stop push button ,ignition switch with key system.(e) Battery charging system including regulator and generator / alternator 84 (viii) Engine shallbe with turbo charger.(ix) Engine protection device against low lubicating oil pressure, high water temperature ,and high oil temperature ,over speeding of engine etc.(x) Water temperature gauge, oil temperature gauge, oil puessure gauge ammeter for display charging + Amps etc. 85 (C) ACCOUSTIC ENCLOSURE FOR DG SET :- Supply and fixing accustic enclosures suitable of 40 KVA capacity diesel Generator set duly fabricasted of channel and CRCA sheet 16SWG of required size having doors , insulation sides and top by minralrock wool confirming to IS-8183 of adequate thickness accoustic louvers /outlet. ventilation system etc . complete as per manufacturers instructions with wiring and lighting arrangements duly painted of three coats of dulux gloss synthetic enamalled paint over a primer coat or as directed of suitable size all as required at site and comprising of the following :- 86 (i) Base: MS channel fabricate MS channel made out of 5 mm thick MS sheet of ISMC suitable section .(ii) Structure heavy duty rectangular MS box channel .(iii) Doors fabricated from MS CRCA 2 mm thick air tight with neoprene rubber gasket and gun metal heavy duty spring loaded locks .(iv) Out side cover: Made out of CRCA sheet 2 mm thick.(v)Accustic insulation ( side &Top )sound proofing minerla rock wool slab of density 96Kg/m3confirming to IS 0183 thickness 100mm covered by fire Resistant fiber tissue as per manufacturer recommandation .Test report from original manufacturer to be submittedbefore incorporation in the work for authenticity of material .(vi) Inside cover : CRCA perforated sheet 0.6mm thick powder coated .(vii) Inspection port : Aluminium frame with double wwalled glass fixed type sealed with neoprene rubber gasket for viewing instrument panel . 87 (D)AMF CONTROL PANEL:- As per manufacturers design with the following equipments. (a) 2 Nos. , 3 pole, suitable ratingcontactor -L&T,Crompton, C&S,GE.(b) 02 Nos MCCB of sutable type and rating for DG/Mains incoming-L&T/GE/ C&S(LG ).© Frequency meter -Enercon/Caddle/ AE/ C&S(LG).(d) Ammmeter with suitable CT,s with selector switch-Enercon/Caddle/AE.(e)Voltmeter with suitable switch-Enercon/Caddle/AE.(f) Frequency meter -Enercon/Caddle/AE. 88 AMF logic :The AMF panel shall be provided with micro processer based programmable logical control system of Make -C&S (LG) /UTOPIA /SIEMENS. The control system will have the fillowing option:-(a) Start/ stop settings including delay and timing setting duly programmable.(b) programmable timing for idle running .(c) Auto/ manual option for each contractor .(d) Self starting kiks for three times or as per programme .(e) Alarm for any fault with buzzer and indicating lamp .(f) One main supply voltage monitor .(g) One alternator supply voltage monitor .(h) One set of DC control relays and timers.(j) One set of control relays for the automatic control system . 89 (E) RCC FOUNDATION:- RCC FuoundationM 20(as per manufacturer design) ,450 mm overall height, 300mm above floor level and 150 mm below floor level of required size. (Make of Engine :-Cummins/Kirloskar/ Ashok leyland /Ruston/Greaves.(Make of Alternator:-Kirloskar/Jyoti/Stam Ford,Alston, Electric, Jyoti . 90 (F) Acoustic Louvers / Attenuators at Air inlet/outlet :-The acoustic louvers provides excellent sound attenuation and good weather protection. Single blade and chevron blade louvers are manufacturefrom 16 SWG CRCA sheet top section with an acoustic in fill of resin bonded mineral rock wool has a density of 96 Kg/m3 .The under section is formed from 18 SWG CRCA performed sheet after covering with resistance tissues to prevent fire migration or by means of acoustic lined ducts. 91 (G) FUEL TANK :- One No of sheet metal steel tank of suitable capacity of hold diesel sufficient for 12 hours running at full load, mounted on angle iron frame including the following:-(i) Level indicator to indicate level of diesel in tank. (ii) Drain plug with 2.0 mtrs pipe for draain oil.(iii) fuel strainer.(iv) Pipe for fuel.(v) Air vent.(vi) Mannually operated one no. fuel pump. 92 (H) INSPECTION PORT :-Aluminium box frame with double welded glass fix type sealed with neoprene rubber gasket, for viewing instrument panel.(J) VENTILATION :- Forced with suitable fan. 93 (K) WIRING AND LIGHTING :-PVC copper wire concealed in flexible conduit provided with florescent tube light and MCB.(a) Earthing panel (Neutral body).(b) Control Panel .© Cable leads for batteries.(d) Power cable to euipment.(e) Self StarterNOTE :- (a) Generating set will be placed on suitable foundation as recommended by manufacturer .and cost thereof shall be included on the prices quoted .(b)Tools shall be supplied as per manufacturer,s instructions and cost thereof shall be included in the price quoted . 94 SCHEDULE A PART XIV A (Fire Alarm & Fire Fighting) 95 SCHEDULE A PART XIV B (Fire Alarm & Fire Fighting) 96 Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 1.5 sq mm ,2 core, 1100 Volts grade 97 Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 1.5 sq mm ,4 core, 1100 Volts grade 98 Supplying installation testing and commissioning of addressable electronic Hooter with audioable range of 25 to 30 mtr with suitable output wattage.These Hooter should be such that they are capable of public announcement as well as used for fault as requried. 99 S & F active repeater ,silence ,mute, reset,accept,evacute and test controls, DX control panels require a 24 V dc supply and an RS485 card required when used with ZX control panel. 100 Fire pump electric driven engine horizontal end suction cetrifugal type as per relevant IS with CI casing bronze impeller and stainless steel shaftmounted on heavy duty bearings suitable continuous operation 0-150% of rated capacity for 415 Volt 3 Phase 50m Hz AC supply for discharge head 900 LPM at 36 m Head complete with automatic start system in case electric supply failure and mannual Start off having battery of appropriate rating, self starter,foundationcomplete all as directed by Engineer-in-Charge. makes: shakti pumps india ltd/Kirloskar/CG 101 Supply, installation, testing and commissioning out door type cubical panel board outer shell made out of3.15 mm thick CRCA sheet and inner shell made out of 3.15 mm thick CRCA sheet and MS angle of suitable size on PCC 1:2:4 type B-1 platform frame factory fabricated with front and back open able double door systemlouvers and air vent gasket for natural flow of air “U” type gasket shall be used to make the outer shell completely vermin proof .suitable for 3 phase 4 wire 415 Volt, 50 Hz, factory fabricated (Factory approved from CPRI)having modern fabrication and followed by powder coat painting comprising of the following:- (Main Elect Panel ) 102 (a) MCCB 415 volts .4P ,200 Amps 16 KA(incoming)-01 No(b) MCCB 415 volts .4P,63Amps 16 KA(O/G)-03 Nos (for Fire pump & lift)(c) MCCB 415 volts .4P,63 Amps 16 KA(O/G)-01 Nos (for Fire alarm Panel)(d) MCCB 415 volts .4P,100Amps 25 KA(O/G)-01 Nos (for bldg)(e) Space for starter - 01 No(f) Bus bar chamber with and including Aluminium strips (set 4 nos) suitable for 300 ampsduly mounted on porcelain insulators-01 Set(g) DigitalAmp meter 3 phprogrammebale type with suitable CTs -01 Set(h) Digitalvolt meter 3 phprogrammebale type suitable for 500 Volt -01 Set (j)LED Phase indicator R, Y & B-01 Set 103 S&F water type extinguisher(IS: 15683) 9kg capacity 104 S& F light weight squeenze grip type CO2 Extinguisher(IS: 15683) 4.5 kg capacity 105 S&F Dry power (ABC) extinguisher(IS: 15683) 9 kg capacity 106 S&F Dry Mechanical foam extinguisher (IS: 15683) 9 ltr capacity 107 S&F Fire buckets(Dry sand) (IS:2546) 108 S&FFire bucket stand post 109 SCHEDULE A PART XV (Heating Appliances) 110 SCHEDULE A PART XVI (Lightening Conductor) 111 SCHEDULE A PART XVII (Dismantling / Demolition)
Contract Date : Ref. Documents   |   Contract Value : Ref. Documents
Disclaimer

We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.

Tender Detail
Website https://etender.cpwd.gov.in/login.html
Quantity
MSME Exemption No
Tender Type Open Tender
Startup Exemption Click Here