TDR : 56830578
Gujarat Energy Transmission Corporation Limited

Tender Brief :

Surendranagar, Gujarat

Tender For STC-110-2026 Tender for Work of Erection, testing commissioning of Pro. 66KV S/C Line from Exi. 66KV Chokdi S/S To Pro. 66KV Vanod PSS On D/C Tower UG Cable with ACSR_Panther Conductor for catering of 6200 KVA on 66KV voltage class power s

Published: 04 Aug 2026
Opening: Ref Document
Closing: 25 Aug 2026
Amount: 85.43 Lakhs
EMD: 80000
Tender Fee: 5900


Works Bio Gas Plant Diesel Power Plants Electrical Substation Gas Power Plants Geothermal Power Plants
14
Days Left
Tender Summary / Eligibility Criteria
Tender for Work of Erection, testing commissioning of Pro. 66KV S/C Line from Exi. 66KV Chokdi S/S To Pro. 66KV Vanod PSS On D/C Tower UG Cable with ACSR_Panther Conductor for catering of 6200 KVA on 66KV voltage class power supply in respect to Executive Engineer, Sauni Yojna, Division, Rajkot.
Documents Download All
2d2b18769b29431c8eec93e6d061de1c
2d2b18769b29431c8eec93e6d061de1c.html
PBSTC1102026
PBSTC1102026.pdf
TBSTC1102026
TBSTC1102026.pdf
No Boq
No Corrigendum
Probable Bidders

AI engine predicts probable bidders to help you bid strategically.

MSME Exception
Explore More →
Technical
Tender involves procurement of high capacity electrical equipment including diaphragm coupling of pump & motor with 90kW capacity at 2900 RPM. The project scope includes installation, testing, commissioning and operational handover.
Previous / Similar Result
BRR : 9231079 Tender For 66 Kv Substation Sullar; 1 25/31.5 MVA, 66/11kV T/Fs 2 66 kV SF-6 Breaker along with 20% extra SF-6 Gas 3 66 kV Isolator with E/Switch 4 66 kV Isolator without E/Switch 5 66 kV Surge Arrestor 6 66 kV CTs for Line & Bus Coupler (600-300-150/1-1-1A) 7 66 kV CT for T/F (300-200-150/0.577-1-1A) 8 66 kV PT for line 9 66 kV NCT (300-200-150/1A) 10 11 kV NCT (1800-900/5A) 11 11 kV Surge Arrestor 12 11 kV 15 Panel Board (2000A)(including one no. bus sectionalizer panel) 13 66kV C&R Panels with SAS:a) Bus Coupler Protection and Circuit Breaker Panel (Without Auto Reclose) with SAS 14 b) Line Protection and Circuit Breaker Panel (Without Auto Reclose) with SAS with line current differential- cum- distance protection relay 15 c) Transformer Protection and Circuit Breaker Panel (Without Auto Reclose) with SAS 16 9000 KVAR 12.65 kV Automatically Switched Capacitor Bank along with allied equipment as per technical specification 17 220V 100AH Battery San Tubular 18 220 V 20/30 A Battery charger (SMPS) 19 220V D.C.D.B. 20 415 V LT AC Distribution Board 300 A 21 11/0.4 kV Station T/F 200 KVA 22 (a) 1.1 kV Copper Control Cable unarmoured for 66kV bays of size 7Cx4mm2, 4Cx4mm2, 2Cx4mm2,2Cx6mm2, 3Cx2.5mm2, 16Cx2.5mm2, 10Cx2.5mm2 & 7Cx2.5mm2 including junction box etc. refer Section-5 of copper & control cable & Section-7 for switchyard erection. 23 (b) Stainless steel MK (200 TB) 24 11 kV Power Cable XLPE 1C x1000mm2 for T/F to 11kV incomer (4 run per phase for each transformer allocating them 2 runs per phase for each 11kV I/C). 25 Termination kit at both ends for 11 kV XLPE Power Cable(1C x1000 mm2 ) Termination kits for (indoor/outdoor) both ends alongwith assessories constitute a set of each cable. 26 11 kV Power Cable XLPE3C x 400sq mm for Capacitor Bank 27 Termination kit at both ends for 11 kV XLPE Power Cable( 3C x 400 mm2) Termination kits for (indoor/outdoor) both ends alongwith assessories constitute a set of each cable. 28 11 kV Power Cable XLPE 3C x 50 sq mm for station T/F 29 Termination kit at both ends for 11 kV XLPE Power Cable( 3C x 50 mm2) Termination kits for (indoor/outdoor) both ends alongwith assessories constitute a set of each cable. 30 650/1100 Volts 3.5 core 240 mm2 aluminium power cable from Aux. T/F to ACDB. 31 650/1100 Volt 3.5 core 70 mm2 aluminium cable for oil filtration set. 32 650/1100 Volt 4core 16mm2 unarmoured with copper power cable for MLDB and other cable required as per contract for 66 kV bays. 33 Earthing Mat Material. The earth mat will be designed/ quoted for soil resistivity of 50Ωm. In case soil resistivity is more than 50Ωm then the earth mat will be designed for actual soil resistivity. The payment of extra material to be used for earth mat shall be made on pro rata basis. The approximate area of earth mat to be laid is given in the corresponding columns of the substations. However, item will remain a Lot item. (calculations may be made considering fault/shock duration of 1 sec., 5400 m2) 34 Fire Fighting equipments as per section-6:i) 22.5 Kg Capacity FE CO2 type, Trolley Mounted 35 ii) 25 Kg Capacity FE DCP type, Trolley Mounted 36 iii) DCP 10 Kg Capacity, Wall mounted 37 iv) FE CO2 6.5 Kg Capacity, Wall mounted 38 v) DCP 5 Kg Capacity, Wall mounted 39 vi) Foam Type 9 Litre Capacity, Wall mounted 40 vii) Water CO2 9 Litre, Wall mounted 41 viii) Fire Buckets (12 Nos. with stand in one set) 42 Complete lightning of control room building, switch yard area, road and street as per section-7 of the specification:a) Supply and installation of 2 fittings of 240W LED lamps with all accessories for Complete lighting of outdoor Switch yard area as per clause 16.0 of section 7 of the specifications. 43 b) Supply and installation of 35W LED tube on tubular steel poles along with the boundary wall at a distance of 30 meter as per as per clause 16.0 of section 7 of the specification 44 c) Complete lighting of road and street by providing 90W LED lamps on tubular steel poles at a distance of 15meter along the roads and streets as per as per clause 16.0 of section 7 of the specification. 45 d) Supply and installation of post top lantern 40W LED Lamps with all complete accessories at the entrance gate of sub-station. 46 e) Supply and installation of 40W LED Lamps with all complete accessories on corners of control room building. 47 Complete Substation automation system of 66/11kV substation including hardware (along with transducers) and software along with associated equipment for the bays (bay as defined in the technical specification, sec-sub-station automation system) as per technical specification. Name of 66 kV BayPresent Future66 kV T/F Bay2 66 kV Line Bay 46*66 kV Bus Coupler Bay 1 * Provision shall be made in SAS to accomodate future scope (i.e. 6 No. 66 kV bays as per space available in GELO) alongwith present scope.Note: Signals from protection relays in 11 kV incomer would also be wired to substation automation system (SAS) 48 Time synchronization equipment 49 High wall type split AC unit2 Ton capacity for C&R Panel room and SCADA room: (as per technical specification). 50 Computer system (SFF) with: Intel core i5 processor with 11th generation or higher as specified in sectiion-04 51 Multi-Function Monochromatic Laser Jet Machine (A4-25 PPM or more) with print copy and scan function, Duplexing feature, composite cartridge, ADF, A4 or larger flatbed size, Networking and wi-fi both, at least 1 input tray, 3 years on site OEM warranty. 52 BOM FOR SAMAST COMPLIANT IEM (ON SEPARATE CUBICLE) FOR 11KV I/C: 1. (a) 3P4W Interface Energy Meters (ABT type) 0.2s Class 1A with TTB & BCS 53 1 (b) Testing of IEM System from NABL accredited lab 54 2. Wired Indoor Meters Panel suitable for 8 meters 55 3. 16 P Industrial Grade un-managed Network switch 56 4. (a) Data concentrator unit (DCU)/ communication Gateway (IG) with dual SIM Modem along with enclosure and accessories 57 4. (b) 3C x 2.5 Sq. mm Un-armoured cable for DCU and Switches 58 5. Cat-6 cable-unshielded 59 6. PVC conduit Pipe - 3/4 with accessories for Cat-6 cable 60 7. Armored Fibre Optic Cable (2 pair) 61 8. HDPE conduit - 40/33 with accessories 62 9. 4Cx4 Sqmm armoured cable for PT 63 10. 4Cx4 Sqmm armoured cable for CT 64 48V 120AH Battery Bank San Tubular 65 48V SMPS Battery Charger (for 48V 120AH Battery Bank San Tubular Battery) 66 For 66kV Substation HVPNL Chaurmastpur 1. The supply of Numerical Line Current Differential-cum- Back up Distance Protection Relay in place of existing Distance Protection Relay on the existing C&R panels (non-SAS compliant) installed at 66kV S/stn. HVPNL, Chaurmastpur (for 66 kV D/C Chaurmastpur - Sullar Lines)2. The erection/ retrofitting, testing & commissioning of Numerical Line Current Differential-cum- Back up Distance Protection Relay in place of existing Distance Protection Relay on the existing C&R panels (non-SAS compliant) above at sr. no. 40 (1) installed at 66kV S/stn. HVPNL, Chaurmastpur shall be the part of scope of successful bidder. 67 For 66kV Substation HVPNL Layalpur Basti 1. The supply of Numerical Line Current Differential-cum- Back up Distance Protection Relay in place of existing Distance Protection Relay on the existing C&R panels (non-SAS compliant) installed at 66kV S/stn. HVPNL, Layalpur Basti (for 66 kV D/C Layalpur Basti – Sullar Lines).2. The erection/ retrofitting, testing & commissioning of Numerical Line Current Differential-cum- Back up Distance Protection Relay in place of existing Distance Protection Relay on the existing C&R panels (non-SAS compliant) above at sr. no. 41 (1) installed at 66kV S/stn. HVPNL, Layalpur Basti (for 66 kV D/C Layalpur Basti – Sullar Lines) shall be the part of scope of successful bidder. 68 Bolted type 11kV tension string assembly with 3 numbers Anti FOG type disc insulators (E&M strength 9000 kg) per string with all hardware accessories including ball & socket connections and tension clamp sets suitable for twin tarantulla conductor. Alternatively the bidder may quote silicon polymer composite insulator string in place of Disc Insulators 69 66 kV Bolted type tension string assembly with 6 numbers Anti FOG type disc insulators (E&M strength 9000 kg) per string with all hardware accessories including ball & socket connection and tension clamp set suitable for single zebra conductor. Alternatively the bidder may quote silicon polymer composite insulator string in place of Disc Insulators 70 66 kV bolted type tension string assembly with 6 numbers Anti FOG type disc insulators (E&M strength 9000 kg) per string with all hardware accessories including ball & socket connections and suspension clamp set suitable for Twin zebra conductor. Alternatively the bidder may quote silicon polymer composite insulator string in place of Disc Insulators 71 66 kV bolted type suspension string assembly with 5 numbers Anti FOG type disc insulators (E&M strength 9000 kg) per string with all hardware accessories including ball & socket connections and suspension clamp set suitable for Singlezebra conductor. Alternatively the bidder may quote silicon polymer composite insulator string in place of Disc Insulators 72 66 kV bolted type suspension string assembly with 5 numbers Anti FOG type disc insulators (E&M strength 9000 kg) per string with all hardware accessories including ball & socket connections and suspension clamp set suitable for Twin zebra conductor. Alternatively the bidder may quote silicon polymer composite insulator string in place of Disc Insulators 73 Boltless C-Type Wedge connectors matching with conductor size. 74 Copper lugs glands, PVC ferrules for control cabling. 75 Fiber cleats, Aluminium clamps, bolts, nuts, washers etc., for fixing control cables in trenches. 76 Galvanized iron perforated tray with side coupler plate bolts, nuts, washers and clamps etc. of size 75x25x2 mm, 150x25x2mm, 100x25x2mm etc. & G.I. Conduits of 50mm/100mm dia from equipment to main trench as per Section-7, Switchyard erection. 77 ACSR Zebra Conductor 78 AAC Tarantulla Conductor 79 7/3.15 GS Earth wire 80 Spacers for Twin Tarantullaand Twin Zebra Conductor 81 U-bolt 20mm dia. 82 Mandatory spares for hardware/mechanical/Electrical auxiliaries to be supplied. 10 % of the finally approved quantities for item mentioned from Sr. No. 68 to 72. 83 2.5 ″ dia HDD/PVC pipe for 4c x 4 mm2 c/cable from CT, VT to maintaining system as per sec-5. 84 Item for associated structure workA)‘Lattice type steel structure for 66 kV AIS Sullar. Supply of material, preparation of fabrication drawing, galvanizing and delivery of lattice type steel structure for tower and beams for 66/11KV switchyard fabricated from steel conforming to IS: 2062 including nuts-bolts gusset plates foundation bolts and other accessories as per drawings supplied by the owner:Main S/Stn. tower and beam:a)Tower type CT-4 85 b) Tower type CT-5 86 c) Tower type CT-6 87 d) Tower type CT-8 88 e) Beam type CB-6 89 f) Beam type CB-7 90 g) Tower type DT-2 91 h) Tower type DT-3 92 i) Beam type DB-2X 93 B) Equipment Structure:a) 66 kV CT Drg. No. HTD/ST-88R 94 b) 66 kV NCT Drg. No. HTD/ST-145 (if required ) 95 c) 66 kV PT Drg. No. HHW/ST-66 96 d) 66 kV Surge Arrestor Drg. No. HTD/ST-89 97 e) 66 kV Isolator Drg. No. HTD/ST-87R 98 f) 66 kV L&E Switch Drg. HTD/ST-87R 99 g) 11 kV NCT Drg. HTD/ST-149 (if combined structure used) or 11 kV NCT Drg. HTD/ST-88R (if required). 100 EARTH WORK :Earth filling with good earth (as per satisfaction of Executive Engineer/Civil Works Division), laying in layers (as per specification), dressing, including carriage, irrespective of lead, loading, unloading, watering and compaction in layers with roller including compensation of earth complete in all respect. 101 2. FOUNDATIONS:Supply of labour, T&P, material and construction of RCC footings & pedestals etc. for steel gantry and equipment structures complete in all respects as per technical specifications & approved drawings including cost of excavation, concreting, cement, reinforcement steel, form work, grouting, holding down bolts, backfilling etc.and other items not mentioned herein but required for the completion of work.A. GANTRY TOWERS66kV sidei) CT-4 102 ii) CT-5 103 iii) CT-6 104 iv) CT-8 105 33kV sidei) DT-2 106 ii) DT-3 107 B. EQUIPMENT 66kV sidei) 66KV LA 108 ii) 66KV CVT/PT 109 iii) 66KV NCT 110 iv) 66kV CT 111 v) 66kV L&E & Isolator 112 11kV sidei) 11kV NCT 113 3. BREAKER FOUNDATIONDesign, engineering, supply of labour, material, equipment & const. of foundations for breaker including all associated works PCC, RCC, structural steel, steel reinforcement & any other item not specifically mentioned herein but reqd. for completion of work as per tech. spec.i) 66 kV Breaker Foundation 114 4. CAPACITOR BANK FOUNDATIONSDesign, Engg. & supply of labour, material & construction of foundations for following rating capacitor bank with capacitor unit (with allied equipments) & series Reactor etc. including chain link fencing 1.8M height around cap. bank complete in all respect including any other items not specifically mentioned herein but required for completion of job as per technical specification.i) 9000KVAR 12.65 kV Capacitor Bank 115 5. TRANSFORMER FOUNDATION5.1 Design, Engg., supply of labour, material and construction of foundation for station transformer including all associated works, RCC, PCC, Reinforcement steel, misc. structural steel and other items not mentioned herein but required for the completion of work as per technical specifications.i) 11/0.4kV 200KVA Station T/F 116 5.2 Construction of transformer foundation including all associated works, RCC, PCC, reinforcement steel, misc. structural steel and other items not mentioned herein but required for completion of work as per technical specifications & approved drgs. In case extra foundation(s) has/have to be constructed (as per approved T/F drawing) to complete the job, nothing extra would be paid on this count.i) 25/31.5 MVA 66/11 kV T/F Foundation 117 6. CABLE TRENCHESSupply of labour, material such as cement, reinforcement steel, GI angles, flats, PCC & brick pillars below cable trenches for construction of Out-Door Cable Trenches (ODCT) of required depth/ type with pre-cast RCC covers including associated works like Cable Trench Culverts,crossings for roads and sump- pit-cum-pump chamber with 2HP motor of reputed make, starter, volt meter, amp-meter etc. as per foundation & trench layout plan attached, HVPNL drgs. & tech. specs. complete in all respect. i) D-type trench 118 ii) E-type trench 119 iii) G-type trench 120 iv) H-type Trench 121 v) GI Pipe 122 vi) Sump Pit Cum Pump Chamber 123 7. SITE SURFACING7.1 Providing, supplying & laying 100mm thick PCC (1:4:8) using 20mm nominal coarse aggregates and supplying & spreading 100mm thick layer of 40mm nominal size uncrushed/ crushed/broken stone pebbles over the PCC including construction of toe wall (exposed wall plastered with cement mortar 1:5) to hold 40mm single size uncrushed/ crushed /broken stone pebbles wherever required in the bays covered under the present scope as detailed in the GELO & instructions of engineer incharge. 124 7.2 Providing, supplying & laying 100mm thick in two layers of 50mm each of 20mm nominal size uncrushed/crushed/ broken stone pebbles gravel fill including dressing, rolling & compacting complete in all respects as per specs. & instructions of engineer incharge. 125 8. ROADS & PCC PAVEMENT8.1 Supply of labour, material and construction of cement concrete roads and walkways/shoulders from NH/SH/etc. to Switch yard/Switch house building as per GELO/CLO as per sectional detail drawing no. HCD/SK-181 R1 and technical specification.i) 6.0M wide road (Near main gate of substation) 126 ii) 3.66m wide road within substation land 127 iii) PCC in front and rear of parking area of SH Building as per tech. specification and drawing HCD/SK-172. 128 9. ROAD CULVERTSDesign Engineering and construction of Pipe culvert(s) at suitable locations under the approach road (from main PWD/ HUDA/Municipal/Village road to the sub-station entry point) including, cost of labour, material complete in all respects as per I.R.C. Standards. 129 10. BOUNDARY WALL10.1 Supply of labour, material and construction of front, C & U/C boundary walls including main gate foundations as per GELO/CLO, technical specifications. & HVPNL drg. HCD/TS-1176 R3 including excavation backfilling, lean & DPC complete in all respect.i) 6 ft. high with GI barbed wire on angles at top. 130 ii) 4½ ft. high front wall including providing grill at top of wall & construction of main entrance gate (with wicket gate). 131 iii) 4½ ft. side wall with GI barbed wire 132 10.2 Supply of labour, T&P, material and construction of front, side & U/C boundary walls including main gate(s) (brickwork below DPC level) as per GELO/CLO, tech. spec. & HVPNL drawings complete in all respects. 133 11. U/C FENCING & GATESProviding & fixing chain link fencing including foundations, GI angle iron posts and gate(s) complete as per electrical layout & tech. spec. & as per drawing attached. 134 12. DRAINAGE–CUM-RAIN HARVESTING SYSTEMThe successful bidder shall evolve design & drawing for drains, manholes with RCC covers andsettlement tankincluding preparation of drainage layout drawing for disposal of rain water from building’s roof top & switch yard (s/stn.) area into respective bore well(s) in such a way that there shall be no ponding of water on the roof and switch yard (s/stn.). The layout so developed shall be got approved from the employer. The location of sump-pit-cum-pump chamber shall preferably be locatedon corner(s) of the s/stn. and shall be got decided from the concerned XEN/Civil Works Division on the basis of surroundings of the substation(s). The successful bidder will also supply labour and material for construction of sump-pit-cum-pump chamber as per HVPNL drgs. & provide one no. non clog pump(s) of 5HP of reputed make capacity with main switch, starter, volt meter, Amp. Mtr. etc. (for each sump pit) for disposal of excess water to outfall point. Any other item(s) not mentioned herein but is/are required for completion of works shall be done by the successful bidder without any extra cost to the employer.i) Drain Section-1 135 ii) Drain Section-2 136 iii) Drain Section-3 137 iv) Road Crossing 138 v) Trench Crossing 139 vi) Sump Pit Cum Pump Chamber 140 13. CONTROL ROOM BUILDINGSupply of labour, material, T&P and construction of control room building complete in all respect as per tech. specs. including exterior weather proof paint, interior emulsion, all internal services like water supply including supply & providing of 5000ltr. capacity double layer Sintex/Diplast PVC tank, Sewerage system, electrification including wiring, modular switches, maximum 20W 4ft. long LED tubes with fittings minimum 1960 lumens, ceiling/exhaust fans, Finishing, Plinth protection, RCC flooring, Indoor trenches, Soakage pit near the switch house building, connection of sewerage system to Soakage pit/Sewerage system of local authorities (as applicable), connection to main water supply system of local authority, bore (Tubewell) (as applicable) etc. & any other item not mentioned herein but required for completion of works. 141 14. RCC M-20 inclusive of labour, material, shuttering, Steel reinforcement etc. complete in all respects to compensate excess quantity required to be executed due to difference in existing ground level and the formation level to be fixed after contouring or difference on account of revised drg issued at the time of construction and the tender drg.
Contract Date : Ref. Documents   |   Contract Value : Ref. Documents
BRR : 7296200 Tender For Construction Of 110 Kv Substation Kothakurussi - Erection Of Yard Structures And Equipments At 110 Kv Substation Kothakurussi-Capital work of 110kV Substation,Kothakurussi -Erection of Yard structures and Equipments at 110kV Substation Kothakurussi.-after dragging up to 50M using suitable lifting device carefully without causing any damage to equipments and fastening in the lorry make it ready for transportation as per the direction of the department officers. 2 Unloading one 110/66KV LA from department lorry to substation site using suitable lifting device and dragging to safe place without causing any damage to CT as per the direction of the department officers. 3 Loading one 110/66KV CT / CVT / PT / CC from the place of its storage to department lorry using required lifting device without causing any damage to equipment and its parts. 4 110KV CT, PT 5 110KV NCT 6 11KV NCT 7 Unloading one 110/66KV CT/PT/CVT/CC from department lorry to substation site using suitable lifting device and dragging to safe place without causing any damage to CT as per the direction of the department officers. 8 110KV CT, PT 9 110KV NCT 10 11KV NCT 11 Loading one set 110/66KV Circuit breaker with its interrupting poles, mechanism box, structures and all its accessories safely without causing any damage using necessary lifting devices to department lorry and fastening for transportation 12 Unloading one set 110/66KV Circuit breaker with its interrupting poles, mechanism box, structures and all its accessories safely without causing any damage using necessary lifting devices from department lorry to substation site and stacking properly for safe storage. 13 Loading one 110/66KV LA from the place of its storage to department lorry, if required, after dragging up to 50M using suitable lifting device carefully without causing any damage to equipments and fastening in the lorry make it ready for transportation as per the direction of the department officers. 14 11KV LA 15 Unloading one 110/66KV LA from department lorry to substation site using suitable lifting device and dragging to safe place without causing any damage to CT as per the direction of the department officers. 16 11KV LA 17 Loading one set 110/66KV Line Isolator with its insulator stacks, supporting channels, connecting pipes, isolating rods, earth switches, mechanism box, structures and all its accessories safely without causing any damage using necessary lifting devices to department lorry and fastening for transportation 18 Unloading one set 110/66KV Line isolator with its insulator stacks, supporting channels, connecting pipes, isolating rods, earthing rods, mechanism box, structures and all its accessories safely without causing any damage using necessary lifting devices from department lorry to substation compound and stacking properly for safe storage. 19 Loading 1x500 sq. mm XLPE cable from its place of storage to department lorry and properly without causing any damage to its insulation and make ready for transporting as per the direction of department officers. 20 Unloading 1x500 sq. mm XLPE cable from department lorry to substation site and stacking properly without causing any damage to its insulationas per the direction of department officers. 21 Loading MS / GI materials hard ware fittings of line work and clamps for equipments and bus from the place of its storage to department lorry and make it ready for transportation as per the direction of departmental officers. 22 Unloading MS / GI materials, hard ware fittings of line work and clamps for equipments and bus from department lorry to substation site and stacking for proper storage as per the direction of departmental officers. 23 Transportingby head load, the materials issued departmentally to the site from the place of storage and distribution to erection site 24 Drilling holes in yard structure 25 Cutting of steel angle in yard structure erection 26 Welding charge for welding on iron parts using arc welding as per standards 27 Fabrication of structures for erecting equipments. The GI & MS angles will be supplied departmentally 28 Erection of yard structures and assembling of columns and beams using bolt and nut including punching of holes. 29 Erection of 1 No. 110/66KV CT/PT/CVT/CC/220KV NCT on the already erected structure of above 1.5m height after opening of crates at the place of storage, leading to site carefully keeping at vertically not allowing tilting from vertical position more than the specified angles, keeping lines and levels as per the direction of the departmental officers, including all labour charges, hire charges of tools& tackles etc. 30 Conveying to the erection site and erecting carefully 1 No. 33KV CT/PT/110KV NCT & RVT/NCT(52/36kV) on the already erected structure after opening of crates at the place of storage leading to site carefully keeping at vertically not allowing tilting from vertical position more than the specified angles, keeping lines and levels as per the direction of the departmental officers, including all labour charges, hire charges of tools& tackles etc. 31 Erection of 1 No. 11KV CT/PT/11KV NCT on the already erected structure after opening of crates at the place of storage leading to site carefully keeping at vertically not allowing tilting from vertical position more than the specified angles, keeping lines and levels as per the direction of the departmental officers. 32 Erection of 1 No. 11KV LA (station type ) /11KV Post insulator on the already erected structure after opening of crates at the place of storage leading to site carefully, keeping lines and levels as per the direction of the departmental officers. 33 Erection of 1 No. 110/66KV LA/Post insulator on the already erected structure after opening of crates at the place of storage leading to site carefully, keeping lines and levels as per the direction of the departmental officers. 34 Erection of one set 110/66KV Bus Isolator on the already erected structure including opening crates and conveyance of all accessories from the place of storage to the place of erection to lines and levels, erection of mechanism box , checking operation and aligning properly, including cutting, welding etc.complete as per the direction of departmental officers. 35 Erection of one set 110/66KV line Isolator on the already erected structure including opening crates and conveyance of all accessories from the place of storage to the place of erection to lines and levels including erection of mechanism box checking operation and aligning properly as per the direction of departmental officers. 36 Unpacking carefully and leading one set of 3 pole EHT110/66KV Circuit Breaker from the place of storage, including support structure , mechanism box compressor, pipe lines etc. to site , cleaning and erecting on foundation using suitable lifting tools, after disassembling necessary parts if required, to lines and levels and assembling all the parts , connecting mechanism etc. in complete shape and making ready for commissioning as per the direction of departmental officers. 37 Uncoiling, paving out, stringing and fixing of bus bar using ACSR Kundah / Moose single conductor for one phase of 66/110KV bus of span up to 30M by cutting the conductor to sufficient length, crimping using compressor / bolting the two ends, washing, cleaning and drying the insulator discs, fixing the conductors to the yard structure with sufficient tension using string of insulators and hardware complete. at both ends, fixing of arcing hornes including transportation of materials from the stockyard to the site under the supervision and direction of department staff at site.(All materials will be supplied departmentally at free of cost). 38 Stringing and fixing earth wire of size 7/9, 7/10 or 7/3.15 between top of the columns and to terminal tower at 33/66/110/220KV substations with compressed / bolted ends at proper tension including uncoiling and cutting of conductor , jumpering, giving earth bond connections by drawing the end of the conductor through the columns, jointing where ever necessary providing back stays at the time of stringing etc. as per the direction of the departmental officers. 39 Providinginterconnection between equipments using ACSR Moose/ Kundah/ wolfSingle conductor at both ends with compressed/ bolted ends including uncoiling and cutting of conductor as per the direction of departmental officers. 40 Providing droppers and connecting to lines / equipments or jumper between two buses without suspension insulators using ACSR Moose/ Kundah/ wolfSingle conductor at both ends with compressed/ bolted ends including uncoiling and cutting of conductor as per the direction of departmental officers. (For one phase) 41 Laying of departmentally supplied GI strip/Copper strip of suitable sizeincluding cleaning and neatly bending of strips ,cutting, removing of metal/earth in the yard and burying earth strip to the required depth re-doing the yard metalling as per the direction of the departmental officers. 42 Welding one end of the bended GI strip of size 50x6mm with the riser of the already laid earth mat, welding 150mm in length, 6mm thick on both sides & end of the strip & other end of the strip with yard structure at 2 points 50mm apart each welding points having 50mm length and 6mm thick on both sides & end of the strip including the charges for connecting the strip with structure using bolted joints as per the directions of the department officers. Charges includes hire charges of DC arc welding set, current charges, cost of low hydrogen content DC arc welding electrodes(No.E7018) cost of anti corrosive paint etc. complete.(Structure earthing) 43 Welding overlapping joints of 50x6mm GI strip with 50mm long, 6mm thick welding on all three sides after doing 2 Nos. bolted joints at the centre as specified after cleaning the surface. Charges includes hire charges of DC arc welding set, current charges, cost of low hydrogen content DC arc welding electrodes( No.E7018) cost of anti corrosive paint etc. complete. 44 Welding one end of the bended GI strip of size 50x6mm with the riser of the already laid earth mat, welding 150mm in length, 6mm thick on both sides & end of the strip and connecting other end with nuts & bolts if required as per the directions of the department officers. Charges includes hire charges of DC arc welding set, current charges, cost of low hydrogen content DC arc welding electrodes(No.E7018) cost of anti corrosive paint etc. complete.(Equipment earthing) 45 Welding one end of the GI strip 50x6mm with the structure with a welding length of 50mm & 6mm thickness on both sides & end of the strip and connecting other end with bolts & nuts if required including hire charges of DC arc welding set, current charges, cost of low hydrogen DC arc welding electrodes (No.E7018) cost of anti corrosive paint etc. complete. 46 Fixing departmentally supplied marshalling kiosk in the existing PT/CT structure by making suitable fixing arrangements including cutting , welding, drilling holes etc as required. 47 Collecting from store or substation wherever available tools and materials such as jacks pulling and lifting machines,rails,sleepers, plies, ropes, empty drums, dummy plates, bolts and nuts gaskets, etc. including loading and unloading in department vehicle and accompanying and returningthe same after completing the work as per the direction of departmental officers.( Only if required) 48 Unloadingthe power transformers of weight 20T to 30T, carefully and safely inch by inch inserting railsand trawling to the platform made with sleepers and thus lowering very carefully inch by inch for placing on the rail track and hoisting to the plinth with out causing damage to transformer and accessories as per the direction of the departmental officer observing all safety precautions. 49 Pulling the power transformers of weight 20T to 30T, on the rail track, travelling for a distance up to 30M, using sleepers, rails, jacking, pulling and keeping ready for placing on the correct plinth as per the direction of departmental officers at site, safely without damaging any equipments and observing all safety precautions. 50 Loading to the department lorry the accessories of 10/12.5MVA transformer such as bushings with proper package, coolers, conservator tank, connecting pipes, bolt and nuts, wheels, rollers, fans, driving mechanism, cooler control box and oil drums etc. safely fastening them properly, accompanying the vehiclewith transformer from ……………….. to ……………and unloading and stacking in convenient place, taking all safety precautions as per the direction of departmental officers. 51 Assembling the 10 /12.5 MVA, 110/11 or 66/11KV transformer with all accessories in complete shape and filling oil if required including arresting the movement of the transformer by locking as per the direction of the departmental officers. 52 Covering the transformer with tarpaulin using ropes, bamboos etc. 53 Giving three phase connection to the filter unit from the supply mains using cable including fitting three numbers of fuse units near the filter unit and laying the cable from control room to filter unit and trial run of filter unit after giving connection etc. complete. ( Only iffound absolutely necessary and where departmental staff is not available ). 54 Hot oil circulation after draining oil from transformer, evacuating the transformer by using vacuum pump after providing LT connection to the pump , connecting the hose to transformer, operating carefully and continuously for attaining sufficient vacuum and keeping in vacuum for 24 hours and operating filter unit carefully and continuously for 24 hours except halt due to poor voltage and trouble in filter plant etc complete as per the direction of dept. officers. 55 Disconnecting the power connections to the filtering plant/ vacuum pump, coiling the cable, disconnect the hoses and coiling them and folding and removing tarpaulin used for covering the transformer, moving the filter plant and vacuum pump to a distant place as directed by the department staff. ( where departmental staff is not available and is found absolutely necessary) 56 Loading the 6000/5000litre/hr.or above transformer oil filter plant tolorry using tripod, chain block, pulley block, rope etc., after pulling it to the convenient position for lifting and fixing it firmly for safe transportation to the location as directed by department officers, unloading the same without causing any damage and placing it carefully at convenient place etc. complete as directed by department officers at site where ever required. 57 Turning and shifting 6000 L/H capacity transformer oil filtering plant or wheel mounted 10000/15000 Litre. oil tank with all accessories for a distance of 20Mto road, towingthe machine with department lorry by the use of D-Shackle and iron ropes , accompanying the lorry including supervision through out the journey especially in turnings to avoid falling of plant. Remove the machine from the lorry and drags up to 10M for safe storage where ever required. 58 Loading the empty oil tank of capacity 10000/15000 Ltr. From the place of its storage using wooden blocks, lever etc. and moving the tank to a distance of 10M from switch yard then loading the same to the dept. vehicle using chain pulley etc. carefully tying the tank in vehicle accompanying the vehicle up to Kothakurussisubstation, removing ties andunloading the tank carefully by the use of wooden blocks rails, chain pulley etc. again moving the tank to a distance of 50M, for safe storage. 59 Loading one vacuum plant of capacity 3HP with its pipelines to department lorry and unloading the same at the required substation as per the direction of departmental officers. 60 Laying 1 x 500 sq mm XLPE cables in trench including drawing through pipes wherever necessary 61 Doing out door/indoor cable termination of 1x500 mm2 11KV XLPE cable very carefully observing directions of manufactures and departmental staff including crimping of socket 62 For mounting 1 x 500 mm2 out door / indoor cable termination 63 Unpacking the transformer / feeder C&R panels, 110V battery charger, OLTC cubicle LT panel at the place of storage transporting to the place of erection and erecting after providing foundation bolt keeping to lines and levels as per the direction of departmental officers. 64 Unpacking at the place of storage and transporting 11KV indoor VCB/SF6 switch gear panel and its accessories to the place of erection and erecting after fixing foundation bolts by chipping concrete wherever necessary, tightening, keeping lines and levels taking all safety precautions including erection of potential transformers as per the direction of departmental officers. 65 Interconnection of panels and 11KV bus bars after opening covers, earthing, inter panel wiring, etc. and making ready for commissioning of breaker as per the direction of the departmental officers. 66 Assembling 55 cells of 100AH conventional battery, pore the acid in required level, connect the battery to the charger and charge to the required specific gravity level, check the specific gravity and voltage of each cells hourly. After attaining the required specific gravity and voltage keep the same for 24 hours, discharge the same up to 50% of the rating and then boost charge the same monitor the voltage and specific gravity regularly and make the battery ready for station use. 67 For 200AH Battery 68 Preparing wiring schedule per transformer / feeder bay of 110 or 66kV with details of type of cable, core and colour, ferrule No. and terminal no of equipments/panelsincluding giving full details in A4 sheet with computer print providing outer border line and sheet no etc. and supplying in the shape of book with special binding etc. and assisting the departmental officers at the time of relay testing and commissioning 69 Master Copy 70 Additional Copy 71 Uncoiling 20/19 core 2.5sqmm, 12 core 4 sqmm control cable (Armoured or un armoured) from cable drums cutting to required length and laying through trench/pipe/cable tray grouping the same neatly using cable tie and carefullyincluding for providing loop wherever necessary and providing cable marker at both ends of cable as per direction of departmental staff at site. 72 Uncoiling 12/7/6 core 2.5 sq mm control cable (armoured and un armoured) from cable drums and cutting to required length and laying through trench/pipe/cable tray grouping the same neatly using cable tie and carefullyincluding for providing loops wherever necessary and cable marker, at both ends of cable as per direction of departmental staff at site. 73 Uncoiling 4/2 core 2.5sqmm control cable (armored or unarmored) from cable drums and cutting to required length and laying through trench/pipe/cable tray neatly and carefully including for providing loops wherever necessaryand cable marker at both ends of cable as per direction of departmental staff at site. 74 Uncoiling 5/4/3/2 core 4sqmm control cable(armoured or un armoured) from cable drums and laying through trench/pipe/cable tray neatly and carefully including for providing loops wherever necessaryand cable marker at both ends of cable as per direction of departmental staff at site. 75 Fixing all type of terminal connecting strip with terminal connectors in the marshalling box or panel boardwherever necessary (terminal connecting strip will be supplied departmentally ) charges includes for providing necessary suitable hole etc complete as per direction of departmental staff at site. 76 Termination of cables in panel by using cable glands of fixing the cable rigidly by any means as per direction of departmental staff at site charges include for providing necessary suitable hole in the gland plate etc. 77 20/19 core 2.5sqmm cable/12 core 4 sqmm cable (using gland of size 28-32mm) 78 12/7/6 core 2.5 sqmm cable (using gland of size 25mm) 79 4/2 core 2.5 sq mm cable/4/2 core 4 sq mm cable (using gland of size 16-22mm) 80 Doing termination of all sizes of PVC insulated copper control cable 2.5mm², pealing, providing number and letter ferrules in the wire, stripping ends, crimping with suitable lugs and connecting to the terminals in the panel board and marshalling kiosk etc., neatly and carefully including cost of copper sockets and ferrules as per the direction of Departmental Officers at site. 81 Doing termination of all sizes of PVC insulated copper control cable 4.0 mm², pealing, providing number and letter ferrules in the wire, stripping ends, crimping with suitable lugs and connecting to the terminals in the panel board and marshalling kiosk etc., using cable tieand cable tie neatly and carefully including cost of copper sockets and ferrules as per the direction of Departmental Officers at site. 82 Supplying aluminium cable tags punching number and alphabets up to 7 digits and binding to cable using copper wire including cost of all materials as per the direction of Board Officials at site. 83 Making of cable clamps using 25x 3 mmGI strip (hot dipped)as per no of cablesin cable tray cutting and holing to required length and for fixing as per the direction of departmental officers at site including supply of suitable nut and bolts. 84 Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m., asdirected by Engineer-in-Charge: All kinds of soil 85 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 86 Supplying and laying tarpaulin sheet of thickness 150GSM of approved make and quality over levelled surface including cost of tarpaulin sheet, wastage overlaps, conveyance and labour charges ect. Complete. 87 Supply and stacking Stone Aggregate (Single size) : 20 mm nominal size 88 Spreading 40mm stone aggregate/20mm stone aggregate in the yard about thickness of 15cm as per the direction of department officers at site 89 Conveying of precast RCC slabs (of various size) manually from stacking place within initial lead etc. complete and laying carefully in position without damaging the edges of slabs as well as cable trench side wall as per directions of Engineer-in- Charge. 90 Loading HT A type pole from the stacking place and unloading the same at work site (transport by vehicle). 91 Transporting poles by hired vehicle to a distance upto 5km and carrying upto 4 poles excluding loading & unloading. 92 Fitting and erecting one HT DP using A type pole in position incl. fitting 2 channel cross arms, digging & back filling pit, drawing earth leads. 93 Drilling hole of various sizes on existing Channel/Cross Arm. 94 Additional rate for excavation of Pit for A type pole in Hard Laterite. 95 Providing one Earth using earth pipe including digging separate pit at standard distance away from the pole/structure & backfilling. 96 Additional rate for excavation of one Earth Pit (2.5m depth) in Hard Laterite 97 Fitting one Additional 3m Channel cross arm (35x35x5mm), in existing 11kV DP incl. conveyance of materials. 98 Erection of one set 11KV Isolator / AB switch (station class)on the already erected structure including opening crates and conveyance of all accessories from the place of storage to the place of erection to lines and levels including erection of mechanism box checking operation and aligning properly as per the direction of departmental officers. 99 Erecting one 250kVA Transformer to existing Plinth/Platform and giving connections,includingloading from TMR/SRS/other stacking place & unloading at site but excluding cost for transporting transformer 100 Providing concrete muffing (0.45x0.45x1.5m) inclusive of cost of all material (as per specification). 101 Loading 3x300 sq. mm XLPE cable from its place of storage to department lorry and properly without causing any damage to its insulation and make ready for transporting as per the direction of department officers. 102 Unloading 3x300 sq. mm XLPE cable from department lorry to substation site and stacking properly without causing any damage to its insulationas per the direction of department officers. 103 Laying 3 x 300 sq mm XLPE cables in trench including drawing through pipes wherever necessary. 104 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11KV gradedirect in ground including excavation, sand cushioning,protective covering and refilling the trench etc as required. 105 Doing out door/indoor cable termination of 3x300 mm233KV XLPE cable very carefully observing directions of manufactures and departmental staff including crimping of socket 106 Mounting one 3x300 mm2 XLPE out door cable termination of structures very carefully without causing any damaged to the drilling holes wherever necessary as directed by the departmental officers 107 Random rubble masonry in CM 1:6 for foundation and basement including cost of all materials, conveyance, labour charges, etc. complete as perspecifications.
Contract Date : 29 Apr, 2025   |   Contract Value : 45.02 Lakhs
BRR : 9231097 Construction Of 66 Kv Ais Substation Mussimble, Yamuna Nagar With 2X25/31.5 Mva 66/11 Kv Power T/Fs And 66 Kv Ais Substation Sadopur, Ambala With 2 X 25/31.5 Mva 66/11 Kv T/Fs On Turnkey Basis-- 1 25/31.5 MVA 66/11 kV T/Fs 2 66 kV SF-6 Breaker along with 20% extra SF-6 Gas 3 66 kV Isolator with E/Switch 4 66 kV Isolator without E/Switch 5 66 kV Surge Arrestor 6 66 kV CTs for Line & Bus Coupler (600-300-150/1-1-1A) 7 66 kV T/F CT (300-200-150/0.577-1-1A) 8 66 kV PT for line 9 66 kV NCT (300-200-150/1A) 10 11 kV NCT (1800-900/5A) 11 11 kV LA 12 11 kV 15 Panel Board 2000A (including one no. bus sectionalizer panel) 13 66kV C&R Panels with SAS:a) Bus Coupler Protection and Circuit Breaker Panel (Without Auto Reclose)with SAS compliant 14 b) Line Protection and Circuit Breaker Panel (Without Auto Reclose) with SAS 15 c) Line Protection and Circuit Breaker Panel without Auto Reclose (SAS Compliant) with Line Current Differential-cum-Distance Protection Relay (for 66 kV D/C Dhulkote-Sadopur Lines) 16 d) Line Protection and Circuit Breaker Panel without Auto Reclose (SAS Compliant) with Distance Protection Relay (for 66 kV S/C Layalpur Basti-Sadopur Lines) 17 e) Transformer Protection and Circuit Breaker Panel (Without Auto Reclose)with SAS compliant 18 9000 KVAR 12.65 kV Automatically Switched Capacitor Bank along with allied equipments as per technical specification. 19 220V 100AH Battery San Tubular 20 220 V 20/30A Battery charger (SMPS) 21 220V D.C.D.B. 22 415 V LT AC Distribution Board 300 A 23 11/0.4 kV Station T/F 200 KVA 24 (a) 1.1 kV Copper Control Cable unarmoured for 66kV bays of size 7Cx4mm2, 4Cx4mm2, 2Cx4mm2, 2Cx6mm2, 3Cx2.5mm2, 16Cx2.5mm2, 10Cx2.5mm2 & 7Cx2.5mm2 including junction box etc. refer Section-5 of copper & control cable & Section-7 for switchyard erection 25 (b) Stainless steel MK (200 TB) 26 a) 11 kV Aluminium Power Cable XLPE 1C x1000mm2 for T/F to 11kV incomer (4 runs per phase for each transformerallocating them 2 runs per phase for each 11kV I/C) 27 b) Termination kit at both ends for 11kV XLPE power Cable (1C x 1000mm2) Termination Kits for (Indoor/Outdoor) both ends along with accessories constitute a set for each cable. 28 a) 11 kV Aluminium Power Cable XLPE 3C x 400sq mm for Capacitor Bank 29 b) Termination kit at both ends for 11kV XLPE power Cable (3C x 400mm2) Termination Kits for (Indoor/Outdoor) both ends along with accessories constitute a set for each cable. 30 a) 11 kV Aluminium Power Cable XLPE 3C x 50 sq. mm for station T/F 31 b) Termination kit at both ends for 11kV XLPE power Cable (3C x 50mm2) Termination Kits for (Indoor/Outdoor) both ends along with accessories constitute a set for each cable. 32 650/1100 Volts 3.5 core 240 mm2 aluminium power cable from Aux. T/F to ACDB. 33 650/1100 Volt 3.5 core 70 mm2 aluminium cable for oil filtration set. 34 650/1100 Volt 4core 16mm2 unarmoured with copper power cable for MLDB and other cable required as per contract for 66kV bays. 35 Earthing Mat Material. The earth mat will be designed/quoted for soil resistivity of 50Ωm. In case soil resistivity is more than 50Ωm then the earth mat will be designed for actual soil resistivity. The payment of extra material to be used for earth mat shall be made on pro rata basis. The approximate area of earth mat to be laid is given in the corresponding columns of the substations. However, item will remain a Lot item (calculations may be made considering fault/shock duration of 1 sec).(7400 sq. meter for Mussimble & 5900 sq. meter for Sadopur) 36 Fire Fighting equipments as per section-6:i) 22.5 Kg Capacity FE CO2 type, Trolley Mounted 37 ii) 25 Kg Capacity FE DCP type, Trolley Mounted 38 iii) DCP 10 Kg Capacity, Wall mounted 39 iv) FE CO2 6.5 Kg Capacity, Wall mounted 40 v) DCP 5 Kg Capacity, Wall mounted 41 vi) Foam Type 9 Litre Capacity, Wall mounted 42 vii) Water CO2 9 Litre, Wall mounted 43 viii) Fire Buckets (12 Nos. with stand in one set) 44 Complete lightning of control room building, switch yard area, road and street as per section-7 of the specification:a) Supply and installation of 2 fittings of 240W LED lamps with all accessories for Complete lighting of outdoor Switch yard area as per clause 16.0 of section 7 of the specifications. 45 b) Supply and installation of 35W LED tube on tubular steel poles along with the boundary wall at a distance of 30 meter as per as per clause 16.0 of section 7 of the specification 46 c) Complete lighting of road and street by providing 90W LED lamps on tubular steel poles at a distance of 15meter along the roads and streets as per as per clause 16.0 of section 7 of the specification. 47 d) Supply and installation of post top lantern 40W LED Lamps with all complete accessories at the entrance gate of sub-station. 48 e) Supply and installation of 40W LED Lamps with all complete accessories on corners of control room building. 49 Complete Substation automation system of 66/11kV substations including hardware (along with transducers) & software along with associated equipment for the bays (bay as defined in the technical specification, sec-substation automation system) as per technical specification.66 kV Mussimble Present FutureSr. No.DescriptionNo. of 66 kV Bays1. T/F2 12.Line 223. B/C 1-66kV SadopurNo. of 66 kV Bays Sr. No.DescriptionPresent Future1. T/F 2 6*2.Line3 3. B/C 1 * As per space available in GELO. Accordingly, provision shall be made in SAS to accommodate future scope along with present scope. Note: signals from protection relays in 11 kV incomer would also be wired to substation automation system (SAS) 50 Time synchronization equipment 51 High wall type split AC unit of 2 Ton capacity for SCADA room & C&R Panel room (as per technical specification). 52 Computer system (SFF) with: Intel core i5 processor with 11th generation or higher as specified in Section-04 53 Multi-Function Monochromatic Laser Jet Machine (A4-25 PPM or more) with print copy and scan function, Duplexing feature, composite cartridge, ADF, A4 or larger flatbed size, Networking and wi-fi both, at least 1 input tray, 3 years on site OEM warranty 54 BOM FOR SAMAST COMPLIANT IEM (ON SEPARATE CUBICLE) FOR 11KV I/C:1 (a) 3P4W Interface Energy Meters (ABT Type) 0.2s Class 1A with TTB & BCS (2 No. for each 11 kV Incomer) 55 1 (b) Testing of IEM System from NABL accredited lab 56 2. Wired Indoor Meters Panel suitable for 8 meters 57 3. 16 P Industrial Grade un-managed Network switch 58 4 (a) Data concentrator unit (DCU)/communication Gateway (IG) with dual SIM Modern alongwith enclosure and accessories 59 4 (b) 3C x 2.5 sq. mm Un-armoured cable for DCU and Switches 60 5. Cat-6 cable-unshielded 61 6. PVC conduit pipe-3/4 with accessories for Cat-6 cable (In line with cat-6 cable) 62 7. Armored Fibre Optic Cable (2 pair) 63 8. HDPE conduit - 40/33 with accessories (In line with armored cable for CT/PT) 64 9. 4Cx4 Sqmm armoured cable for PT 65 10.4Cx4 Sqmm armoured cable for CT 66 48V 120AH Battery Bank San Tubular 67 48V SMPS Battery Charger (for 48 V 120 AH Battery Bank San Tubular Battery) 68 For 220 kV Substation, BBMB, Dhulkote: 1. The supply of Numerical Line Current Differential-cum- Back up Distance Protection Relay for C&R Panels (non-SAS compliant)installed at 220 kV Substation, BBMB, Dhulkote (for 66 kV D/C Dhulkote - Saddopur Lines). 69 2. The erection/ retrofitting, testing & commissioning of Numerical Line Current Differential-cum- Back up Distance Protection Relay in place of existing Distance Protection Relay on the existing C&R Panels (non-SAS compliant) above at sr. no. 68 installed at 220 kV Substation, BBMB, Dhulkote (for 66 kV D/C Dhulkote - Saddopur Lines) shall be the part of scope of successful bidder. 70 Bolted type 11kV tension string assembly with 3 numbers Anti FOG type disc insulators (E&M strength 9000 kg) per string with all hardware accessories including ball & socket connections and tension clamp sets suitable for twin tarantulla conductor. Alternatively the bidder may quote silicon polymer composite insulator string in place of Disc Insulators 71 66 kV Bolted type tension string assembly with 6 numbers Anti FOG type disc insulators (E&M strength 9000 kg) per string with all hardware accessories including ball & socket connection and tension clamp set suitable for single zebra conductor. Alternatively the bidder may quote silicon polymer composite insulator string in place of Disc Insulators 72 66 kV Bolted type tension string assembly with 6 numbers Anti FOG type disc insulators (E&M strength 9000 kg) per string with all hardware accessories including ball & socket connection and tension clamp set suitable for twin zebra conductor. Alternatively the bidder may quote silicon polymer composite insulator string in place of Disc Insulators 73 66 kV bolted type suspension string assembly with 5 numbers Anti FOG type disc insulators (E&M strength 9000 kg) per string with all hardware accessories including ball & socket connections and suspension clamp set suitable for single zebra conductor. Alternatively the bidder may quote silicon polymer composite insulator string in place of Disc Insulators 74 66 kV bolted type suspension string assembly with 5 numbers Anti FOG type disc insulators (E&M strength 9000 kg) per string with all hardware accessories including ball & socket connections and suspension clamp set suitable for twin zebra conductor. Alternatively the bidder may quote silicon polymer composite insulator string in place of Disc Insulators 75 Boltless C-Type Wedge connectors matching with conductor size. 76 Copper lugs glands, PVC ferrules for control cabling. 77 Fiber cleats, Aluminium clamps, bolts, nuts, washers etc., for fixing control cables in trenches. 78 Galvanized iron perforated tray with side coupler plate bolts, nuts, washers and clamps etc. of size 75x25x2 mm, 150x25x2mm, 100x25x2mm etc. & G.I. Conduits of 50mm/100mm dia from equipment to main trench as per Section-7, Switchyard erection. 79 ACSR Zebra Conductor (approx.) 80 AAC Twin Tarantulla Conductor (approx.) 81 7/3.15 GS Earth wire 82 Spacers for TwinTarantulla/ZebraConductor 83 U-bolt 20mm dia. 84 Mandatory spares for hardware/mechanical/Electrical auxiliaries to be supplied. 10 % of the finally approved quantities for item mentioned from Sr. No. 70 to 74. 85 2.5 ″ dia HDD/PVC pipe for 4c x 4 mm2 c/cable from CT, VT to maintaining system as per sec-5, chapter-5. 86 Item for associated structure workA)‘‘Lattice type steel structure for 66kV AIS Mussimble (Yamuna Nagar) & Sadopur (Ambala), Supply of material, preparation of fabrication drawing, galvanizing and delivery of lattice type steel structure for tower and beams for 66/11KV switchyard fabricated from steel conforming to IS: 2062 including nuts-bolts gusset plates foundation bolts and other accessories as per drawings supplied by the owner.66kV Cable support structure of galvanized iron along with foundation to be designed by bidder as per site requirement/size of cableMain S/Stn. tower and beam:a)Tower type CT-4 87 b) Tower type CT-5 88 c) Tower type CT-6 89 d) Tower type CT-8 90 e) Beam type CB-6 91 f) Beam type CB-7 92 g) Tower type DT-2 93 h) Tower type DT-3 94 i) Beam type DB-2X 95 B) Equipment Structure:a) 66 kV CT Drg. No. HTD/ST-88R 96 b) 66 kV NCT Drg. No. HTD/ST-145 (if required ) 97 c) 66 kV PT Drg. No. HHW/ST-66 98 d) 66 kV Surge Arrestor Drg. No. HTD/ST-89 99 e) 66 kV Isolator Drg. No. HTD/ST-87R 100 f) 66 kV L&E Switch Drg. HTD/ST-87R 101 g) 11 kV NCT Drg. HTD/ST-149 (if combined structure used) or 11 kV NCT Drg. HTD/ST-88R (if required). 102 1. EARTH WORK 1.1 Earth filling with good earth (as per satisfaction of Executive Engineer/Civil Works Division), laying in layers (as per specification), dressing, including carriage, irrespective of lead, loading, unloading, watering and compaction in layers with roller including compensation of earth complete in all respect. 103 1.2 DewateringDewatering of subsoil water for lowering of water table to enable excavation of earth, concreting for all type of works and backfilling, by boring of tube wells or deploying well point system so that continuous lowering of water table is made till completion of work, without disturbing the soil characteristics. The rate shall include all type of expenditure for required dewatering arrangements. 104 2. FOUNDATIONSWORK FOR 66 KV MUSSIMBLE:Supply of labour, T&P, material and construction of RCC footings & pedestals etc. for steel gantry and equipment structures complete in all respects as per HVPNL standard drawing, technical specifications including cost of excavation, concreting, cement, reinforcement steel, form work, grouting, holding down bolts, backfilling etc.and other items not mentioned herein but required for the completion of work.A. GANTRY TOWERS i) CT-4 105 ii) CT-5 106 iii) CT-6 107 iv) CT-8 108 v) DT-2 109 vi) DT-3 110 B. EQUIPMENT 66kV sidei) 66KV LA 111 ii) 66KV CVT/PT 112 iii) 66KV CT 113 iv) 66kV L&E & Isolator 114 v)66kV NCT 115 11kV sidei) 11kV NCT 116 3. FOUNDATIONS WORK FOR 66 KV SADOPUR:Design engineering & supply of labour, T&P, material and construction of RCC footings & pedestals etc. for steel gantry and equipment structures complete in all respects as per technical specifications & approved drawings including cost of excavation, concreting, cement, reinforcement steel, form work, grouting, holding down bolts, backfilling etc.and other items not mentioned herein but required for the completion of work.The successful bidder shall develop the designs & drawings as per the soil investigation report attached in specification and shall get these checked/vetted from any professsional institute as per contract before final approval.A. GANTRY TOWERS i) CT-4 117 ii) CT-5 118 iii) CT-6 119 iv) CT-8 120 v) DT-2 121 vi) DT-3 122 B. EQUIPMENT 66kV sidei) 66KV LA 123 ii) 66KV CVT/PT 124 iii) 66KV CT 125 iv) 66kV L&E & Isolator 126 v)66kV NCT 127 11kV sidei) 11kV NCT 128 4. BREAKER FOUNDATIONDesign, engineering, supply of labour, material, equipment & const. of foundations for breaker including all associated works PCC, RCC, structural steel, steel reinforcement & any other item not specifically mentioned herein but reqd. for completion of work as per tech. spec.i) 66 kV Breaker Foundation 129 5. RoadsSupply of labour, material and construction of cement concrete roads and walkways/shoulders from NH/SH/etc. to Switch yard/Switch house building as per GELO/CLO as per sectional detail drawing no. HCD/SK-181 R1 and technical specification.i. 6.0m wide road (Near main gate of substation) 130 ii. 3.66 wide road 131 6. CAPACITOR BANK FOUNDATIONSDesign, Engg. & supply of labour, material & construction of foundations for capacitor bank with capacitor unit (with allied equipments) & series Reactor etc. including chain link fencing 1.8M height around cap. bank complete in all respect including any other items not specifically mentioned herein but required for completion of job as per technical specification.i) 9000 KVAR 12.65 kV capacitor bank 132 7. ROAD CULVERTDesign, Engineering and const. of Pipe culvert(s) at suitable locations under the approach road (from main PWD/ HUDA/Municipal/Village road to the sub-station entry point) including, cost of labour, material complete in all respects as per I.R.C. Standards. 133 8. TRANSFORMER FOUNDATION FOR 66 KV MUSSIMBLE : 8.1 Construction of transformer foundation including all associated works, RCC, PCC, reinforcement steel, misc. structural steel and other items not mentioned herein but required for completion of work as per technical specifications & approved drgs. In case extra foundation(s) has/have to be constructed (as per approved T/F drawing) to complete the job, nothing extra would be paid on this count..25/31.5MVA,66/11kV T/F foundationcomplete in all respect. 134 9. TRANSFORMER FOUNDATIONWORK FOR 66 KV SADOPUR: 9.1 Design Engineering & construction of transformer foundation including all associated works, RCC, PCC, reinforcement steel, misc. structural steel and other items not mentioned herein but required for completion of work as per technical specifications & approved drgs. In case extra foundation(s) has/have to be constructed (as per approved T/F drawing) to complete the job, nothing extra would be paid on this count.The successful bidder shall develop the designs & drawings as per the soil investigation report attached in specification and shall get these checked/vetted from any professsional institute as per contract before final approval..25/31.5MVA,66/11kV T/F foundationcomplete in all respect. 135 10 Statipon Transformer Foundation work: Design, Engg., supply of labour, material and construction of foundation for station transformer including all associated works, RCC, PCC, Reinforcement steel, misc. structural steel and other items not mentioned herein but required for the completion of work as per technical specifications.11/0.4kV 200KVA Station T/F 136 11. OUTDOOR CABLE TRENCHES:Supply of labour, material such as cement, reinforcement steel, GI angles, flats, PCC & brick pillars below cable trenches for construction of Out-Door Cable Trenches (ODCT) of required depth/ type with pre-cast RCC covers including associated works like Cable Trench Culverts crossings for roads and sumpit-cum-pump chamber with 2HP motor of reputed make, starter, volt meter, amp-meter etc. as per approved trench layout plan, HVPNL drgs. & tech. specs. complete in all respecti) D-type trench 137 ii) E-type trench 138 iii) F-type trench 139 iv) G-type trench 140 v) H-type trench 141 vi) Road culvert 142 vii) Sump Pit Cum Pump Chamber 143 12. SITE SURFACING:12.1Providing, supplying & laying 100mm thick in two layers of 50mm each of 20mm nominal size uncrushed/crushed/ broken stone pebbles gravel fill including dressing, rolling & compacting complete in all respects as per specs. & instructions of engineer incharge. 144 12.2 Providing, supplying & laying 100mm thick PCC (1:4:8) using 20mm nominal coarse aggregates and supplying & spreading 100mm thick layer of 40mm nominal size uncrushed/ crushed/broken stone pebbles over the PCC including construction of toe wall (exposed wall plastered with cement mortar 1:5) to hold 40mm single size uncrushed/ crushed /broken stone pebbles wherever required in the bays covered under the present scope as detailed in the GELO & instructions of engineer incharge. 145 13. BOUNDARY WALL13.1 Supply of labour, T&P, material & construction of front, side & U/C boundarybelow DPC level as per GELO/CLO, tech. spec. & HVPNL drgs including excavation, PCC, brickwork, back filling, plaster, painting etc. complete in all respects. 146 13.2 Supply of labour, material and construction of front, C & U/C boundary walls above DPC including main gate foundationsas per GELO/CLO, technical specifications. & HVPNL drg. HCD/TS-1176 R3 including DPC complete in all respect.i. 6 ft. high U/C B/wall with barbed wire on angles at top. 147 ii. 4½ ft. high front wall including providing grill at top of wall & construction of gate pillars. 148 iii. 4½ ft. high side wall with barbed wire on angles at top of wall. 149 14. CONTROL ROOM BUILDING FOR 66 KV MUSSIMBLE: Supply of labour, material, T&P and construction of control room building complete in all respect as per tech. specs. including exterior weather proof paint, interior emulsion, all internal services like water supply including supply & providing of 5000ltr. capacity double layer Sintex/Diplast PVC tank, Sewerage system, electrification including wiring, modular switches, maximum 20W 4ft. long LED tubes with fittings minimum 1960 lumens, ceiling/exhaust fans, Finishing, Plinth protection, flooring, Indoor trenches, Soakage pit near the switch house building, Rcc pipe around the building to drain of water,connection of sewerage system to Soakage pit/Sewerage system of local authorities (as applicable), connection to main water supply system of local authority, bore (Tubewell) (as applicable) etc. & any other item not mentioned herein but required for completion of works. 150 15. CONTROL ROOM BUILDING FOR 66 KV SADOPUR:The design of foundation below plinth level is in the scope of successful bidder. However, the architectural design and the structural design above plinth level shall be kept same as per HVPNL standard drawings attached with bidding documents. Design engineering, supply of labour, material, T&P and construction of control room building complete in all respect as per tech. specs. including exterior weather proof paint, interior emulsion, all internal services like water supply including supply & providing of 5000ltr. capacity double layer Sintex/Diplast PVC tank, Sewerage system, electrification including wiring, modular switches, maximum 20W 4ft. long LED tubes with fittings minimum 1960 lumens, ceiling/exhaust fans, Finishing, Plinth protection, flooring, Indoor trenches, Soakage pit near the switch house building, connection of sewerage system to Soakage pit/Sewerage system of local authorities (as applicable), connection to main water supply system of local authority, bore (Tubewell) (as applicable) etc. & any other item not mentioned herein but required for completion of works.The successful bidder shall develop the designs & drawings as per the soil investigation report attached in specification and shall get these checked/vetted from any professsional institute as per contract before final approval. 151 16. U/C FENCING & GATESProviding & fixing chain link fencing including foundations, GI angle iron posts and gate(s) complete as per electrical layout & tech. spec. & as per drawing attached. 152 17. PCC PAVEMENTConstruction of PCC pavement in front, rear or side (as per site requirement of the switch house building) as per drawing no. HCD/SK-172 & technical specifications. 153 18. DRAINAGE–CUM-RAIN HARVESTING SYSTEM for 66 kV substation Mussimble 18.1 Supply of labour, material for construction ofrecharge structures with bore well(s) as per HVPN drawings & specs. complete in all respect . The location of recharge structures shall preferably be located on corner(s) of the substation and shall be got decided from the concerned Engineer in-Charge on the basis of surroundings of the substation(s). In case ground water table is less than 8m from FGL, rain harvesting well shall not be constructed (the drainage system with sump pit is to be constructed as per item mentioned below). 154 18.2 The successful bidder shall evolve design & drawing for drains, manholes with RCC covers andsettlement tankincluding preparation of drainage layout drawing for disposal of rain water from building’s roof top & switch yard (s/stn.) area into respective bore well(s) in such a way that there shall be no ponding of water on the roof and switch yard (s/stn.). The layout so developed shall be got approved from the employer. The location of sump-pit-cum-pump chamber shall preferably be locatedon corner(s) of the s/stn. and shall be got decided from the concerned Engineer in-Charge on the basis of surroundings of the substation(s). The successful bidder will also supply labour and material for construction of sump-pit-cum-pump chamber as per HVPNL drgs. & provide one no. non clog pump(s) of 5HP of reputed make capacity with main switch, starter, volt meter, Amp. Mtr. etc. (for each sump pit) for disposal of excess water to outfall point. Any other item(s) not mentioned herein but is/are required for completion of works shall be done by the successful bidder without any extra cost to the employer.i)Drain Section-1 155 ii) Drain Section-2 156 iii) Drain Section-3 157 iv) Road Crossing 158 v) Trench Crossing 159 vi) Sump Pit Cum Pump Chamber 160 19. DRAINAGE–CUM-RAIN HARVESTING SYSTEM for 66 kV substation Sadopur The successful bidder shall evolve design & drawing for drains, manholes with RCC covers andsettlement tankincluding preparation of drainage layout drawing for disposal of rain water from building’s roof top & switch yard (s/stn.) area into respective bore well(s) in such a way that there shall be no ponding of water on the roof and switch yard (s/stn.). The layout so developed shall be got approved from the employer. The location of sump-pit-cum-pump chamber shall preferably be locatedon corner(s) of the s/stn. and shall be got decided from the concerned Engineer in-Charge on the basis of surroundings of the substation(s). The successful bidder will also supply labour and material for construction of sump-pit-cum-pump chamber as per HVPNL drgs. & provide one no. non clog pump(s) of 5HP of reputed make capacity with main switch, starter, volt meter, Amp. Mtr. etc. (for each sump pit) for disposal of excess water to outfall point. Any other item(s) not mentioned herein but is/are required for completion of works shall be done by the successful bidder without any extra cost to the employer.The successful bidder shall develop the designs & drawings and shall get these checked/vetted from any professsional institute as per contract before final approval.i)Drain Section-1 161 ii) Drain Section-2 162 iii) Drain Section-3 163 iv) Road Crossing 164 v) Trench Crossing 165 vi) Sump Pit Cum Pump Chamber 166 20. RCC M-20 for 66 kV substation Mussimble inclusive of labour, material, shuttering, steel reinforcement etc. complete in all respects to compensate excess quantity required to be executed due to difference in existing ground level and the formation level to be fixed after contouring or difference on account of revised drawing issued at the time of construction and the tender drawing. 167 21. RCC Retaining wall for 66 kV substation Sadopur Design engineering, supply of labour, material and construction of T/L shaped RCC retaining wall below DPC to retain the earth filling complete in all respect. The successful bidder shall develop the designs & drawings as per the soil investigation report attached in specification and shall get these checked/vetted from any professsional institute as per contract before final approval.Difference between NGL & FGL from 2.5 to 3.5 mtr. 168 22. Distamtlement for 66 kV substation Sadopur :-Dismantling of existing residential quarters, OHT and underground tank etc. Dismantling including foundations of following structure. The material whatsoever shall be the property of the successful bidder. The dismantled material shall not be allowed for reuse at any of the sub-stations; however, HVPNL may allow use of bricks for brick ballast purpose only.Dismantling of existing residential quarters, Overhead tank, toilet, boundary wall and underground tank etc complete in all respect.
Contract Date : Ref. Documents   |   Contract Value : Ref. Documents
BRR : 1679638 Upgradation Of 5Km Poopally Kuttanad 66Kv Line To 110Kv Dc Upgradation Of Poopally-Kuttanad Portion Of 66Kv Alappuzha-Kuttanad Feeder To 110 Kv Dc Under Transmission Circle,Alappuzha , Clearing Light Junglesincluding Uprootingof Rank Vegetation, Grass, Brushwood,Trees And Saplingsof Girth Upto 30 Cm .Measured At A Height Of 1M Above Ground Level And Removal Of Rubbish Up To A Distance50 M Outside The Periphery Of The Area Cleared , Dismantling Of Existing 7/9 Or 7/3.66Mm Earth Conductor From The Tower Detaching The Clamps, Connectors And Line Accessories From The Conductor,Winding And Stacking The Same At Site , Dismanling 3 Line Dogfrom The Tower Detaching The Clamps, Connectors And Line Accessories From The Conductor,Winding And Stacking The Same At Site.Take 50% Of The Stringing Rate Vide Item No 66 Of Ksebtransmission Data Dtd 13.04.2020 ( Item No 62 Of This Estimate ). , Dismantling Oftower Super Structure Above Ground Levelincluding Normal And Special Hill Side Extension Members,Detaching Tower Accessories,Nut And Bolts (Where Ever Necessary) From The Tower Angles And Stacking The Same At Site , Transport Of Dismantled Materialssuch As Tower Super Struture , Conductor, Earth Wire, Hardwares Insulators , Etc From Site,Includingloading And Unloading Charges Etc As Directed By Board Staff. To Pathirapally Substati On Compound A)Line And Earth Conductors Upto 10Km , Line And Earth Conductors Above 10 Km (Additional Charges) , Insulators And Accessories, Power Conductor Accessories, Earth Conductor Accessories Etc. Upto 10Km , Insulators And Accessories, Power Conductor Accessories, Earth Conductor Accessories Etc. Above 10 Km (Additional Charges) , Towers, Extensionsand Other Structures And All Other Materials Including Earthing Materials Etc. Upto 10Km , Towers, Extensionsand Other Structures And All Other Materials Including Earthing Materials Etc.Above 10 Km (Additional Charges) , Constructionof Earthern Ring Bunds For Bailing Out Water For Excavation For Foundation And Stub Setting, Includingshoring, If Necessary, With Plaited Coconut Cadjan And Bamboos, Etc. As Per Dimensions Noted Below. Bunds Upto 0.5 M Height, 1 M Bottom Width And 0.5 M Top Width For Facilitating Dismantling Of Existing Tower , Constructionof Earthern Ring Bunds For Bailing Out Water For Excavation For Foundation And Stub Setting, Includingshoring, If Necessary, With Plaited Coconut Cadjan And Bamboos, Etc. As Per Dimensions Noted Below. Bunds Beyond 0.5 M Height To 1 M Height , 1.5 M Bottom Width & 0.5 M Top Width For Facilitating Dismantling Of Existing Tower , Constructionof Earthern Ring Bunds For Bailing Out Water For Excavation For Foundation And Stub Setting, Includingshoring, If Necessary, With Plaited Coconut Cadjan And Bamboos, Etc. As Per Dimensions Noted Below.Bunds Beyond 1 M Height Top Widthto Be 0.5 M And Bottom Width To Be Proportionately Fixedfor Facilitating Dismantling Of Existing Tower , Close Timbering In Case Of Shaft,Well,Cesspit ,Manhole And The Likeincluding Strutting,Shoring And Packingcavities( Where Ever Required) Complete.( Measurement To Be Taken Of The Face Area Timbered) Depth Not Exceeding 1.5M , Close Timbering In Case Of Shaft,Well,Cesspit ,Manhole And The Likeincluding Strutting,Shoring And Packingcavities( Where Ever Required) Complete.( Measurement To Be Taken Of The Face Area Timbered) Depthexceeding 1.5M But Not Not Exceeding 3M , Close Timbering In Case Of Shaft,Well,Cesspit ,Manhole And The Likeincluding Strutting,Shoring And Packingcavities( Where Ever Required) Complete.( Measurement To Be Taken Of The Face Area Timbered) Depthexceeding 1.5M But Not Not Exceeding 3M , Open Timbering Over Areasincluding Strutting, Shoring And Packingcavities( Where Ever Required) Complete. ( Measurement To Be Taken Of The Face Area Timbered)Depth Not Exceeding 1.5M , Open Timbering Over Areasincluding Strutting, Shoring And Packingcavities( Where Ever Required) Complete. ( Measurement To Be Taken Of The Face Area Timbered)Depthexceeding 1.5M But Not Not Exceeding 3M , Open Timbering Over Areasincluding Strutting, Shoring And Packingcavities( Where Ever Required) Complete. ( Measurement To Be Taken Of The Face Area Timbered)Depthexceeding 3M But Not Not Exceeding 4.5M , Dewatering Mechanical- Bailing Out Water With Engine And Pump Set Including Conveyance To Site And Erection Cost Of Fuel, Lubricating Oil And Other Stores, Pay Of Staff Etc.Complete , Dewatering Manual , Earth Work Excavation In All Kinds Of Soil By Mechanical Means (Hydraulic Excavator) / Manual Means Over Areas(Exceeding 30 Cm Depth,1.5M Inwidth As Well As 10 Sqm On Plan), Including Getting Out And Disposal Of Excavated Earth Lead Up To 50 M And Lift Up To 1.5 M. , Earth Work Excavation In All Kinds Of Soil By Mechanical Means (Hydraulic Excavator) / Manual Means Over Areas( Exceeding 30 Cm Depth,1.5M Inwidth As Well As 10 Sqm On Plan), Including Getting Out And Disposal Of Excavated Earth Lead Up To 50 M And Lift 1.5 M To 3M. , Earth Work Excavation In All Kinds Of Soil By Mechanical Means (Hydraulic Excavator) / Manual Means Over Areas(Exceeding 30 Cm Depth,1.5M Inwidth As Well As 10 Sqm On Plan), Including Getting Out And Disposal Of Excavated Earth Lead Up To 50 M Andlift3m To 4.5 M , Demolishing Cement Concrete Manua Lly/ By Mechanical Means Including Disposal Of Material Within 50 Metres Lead As Per Direction Of Engineerin Charge. Nominal Concrete 1:3:6 Or Ric Her Mix (I/C Equivalent Design Mix) , Demolishing R.C.C. Work Manually/ By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer - In- Charge. , Demolishing Brick Work Manually/ By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge. , Demolishing Stone Rubble Masonry Manually/ By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge : , Random Rubble Masonry With Hard Stone In Foundation And Plinth Including Levelling Up Upto Plinth Level Withcement Mortar 1:6 (1 Cement : 6 Coarse Sand) , Plastering On The Top Ofrevetment With 1:4 Cement Mortar 20 Mm Thick . , Pointingthe Outer Faces Of Revetment With Cement Mortar 1:3 , Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Side Of Foundation Etc, In Layers Not Exceeding 20 Cm In Depth Consolidating Each Deposited Layer By Rammingand Watering Lead Up To 50 M Lift Up To 1.5 M , Supplying And Stacking Good Earth At Site , Providing And Constructing Temporary Island 16M Diameter For Construction Of Well Foundation. Assuming The Depth Of Water 2.4M And Height Of Island To Be 3.0 M , Providing And Constructing Temporary Island 16M Diameter For Construction Of Well Foundation. Assuming The Depth Of Water 1.0M And Height Of Island To Be 1.25 M , Forming Temporary Road 1 M ( Foot Path -3 M Wide) ( Works Include S Site Clearing, Earthwork , Formation Of Temporary Road Using Red Earth To Water Logged Tower Locations And Removing The Temporary Road After The Work , Conducting Check Survey, Setting Out Tower Positions On Ground, Pit Marking, All Confirming To The Appro Ved Profile And Tower Schedule Using Digital Theodolites/ Total Station Etc.As Directed By Board Staff , Boring,Providing And Installation Bored Cast-In-Situ Reinforced Cement Concrete Piles Of Grade, M-25 Of Specified Diameter And Length Below The Pile Cap,To Carry A Safe Working Load Not Less Than Specified Excluding The Cost Of Reinforcement,But Including The Cost Of Boring With Bentonite Solution And Temporary Casing Of Appropriate Length For Setting Out And Removal Of The Same And The Length Of The Pile To Embeded In The Pile Cap Etc By Crawler Mounted, Telescopic Boom Hydraulic Piling Rigall Complete.Including Removal Of Excavated Earth With All Its Lifts And Leads (Length Of Pile For Payment Shall Be Measured Up To Bottom Of Pile Cap) Pile Dia 1000Mm Note-Truck Mounted Rotary/Tmr/Tube Well Boring Machine Shall Not Be Used , For 600 Mm Dia Piles , 800 Mm Dia Piles , 1200 Mm Dia Piles , Boring, Providing And Installation Bored Cast-In-Situ Reinforced Cementconcrete Piles Of Grade M-25 Ofdiameter 1000Mm And Length Below The Pile Cap, To Carry A Safe Working Load Not Less Than Specified, Excluding The Pile Cap, To Carry A Safe Working Load Not Less Than Specified, Excluding The Cost Of Steel Reinforcement But Including The Cost Of Boring With Bentonite Solution And Temporary Casing Of Appropriate Length For Setting Out And Removal Of Same And The Length Of The Pile To Be Embedded In The Pile Cap Etc. By Percussion Drilling Using Direct Mud Circulation (Dmc) Or Bailer And Chisel Technique By Tripod And Mechanical Winch Machine All Complete, Including Removal Of Excavated Earth With All Its Lifts And Leads (Length Of Pile For Payment Shall Be Measured Up To Bottom Of Pile Cap). Note: Truck Mounted Rotary/Tmr/Tubewell Boring Mchine Shall Not Be Used (1000Mm Dia) . , For 600 Mm Dia Piles , 800 Mm Dia Piles , 1200 Mm Dia Piles , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Foundations, Footings, Bases For Columns , Providing And Laying In Position Ready Mixed M-25 Grade Concrete For Reinforced Cement Concrete,Using Cement Content As Per Approved Design Mix And Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For All Leads, Having Coninuous Agitated Mixer,Manufactured As Per Mix Design Of Specified Grade For Plain Cement Concrete Work,Including Pumping Of Rmc From Transit Mixer To Site Of Laying And Curing,Excluding The Cost Of Centering,Shuttering And Finishing Including Cost Of Curing Admixtures In Recommended Proportion As Per Is:9103 To Accelerate/Retard Setting Of Concrete,Improve Workability With Out Impairing Strength And Durability As Per Direction Of The Engineer - Incharge Note-: Minimum Cement Content In This Item Should Be @400 Kg/ M3 , Cement Concrete 1:4:8 Mixture With 40 Mmmetal For Tower Footing In Accordance With The Specification Including The Cost Of Cement To Be Supplied By The Contractor At Site, Conveyance Charges Of Cement To Site Of Work, All Hire Charges, Watering, Curing, Etc, Complete. For Pile Cap Pcc , Providing And Laying In Position Cement Concrete Of Specified Grade Excludingthe Cost Of Centering And Shuttering - All Work Up To Plinth Level :1:1½:3 (1 Cement: 1½ Coarse Sand (Zone-Iii) : 3 Graded Stone Aggregate 20 Mm Nominal Size) , Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level With Thermo-Mechanically Treated Bars , Stub Setting (Using Template/Probe) For 110 Kv Towers.Erection Of Stub, Stub Template, Fixing Of Jack For Supporting Template, Allignment And Leveling For Exact Location Of Stubs Of Stub Setting Template, Dismantling Of Template After Completion Of Initial Curing Of Cement Concrete, Movement Of Template From One Location To Another Complete, As Directed By Board Staff. - General Area (For110 Kv Dc Tower) , Stub Setting (Using Template/Probe) For 110 Kv Towers.Erection Of Stub, Stub Template, Fixing Of Jack For Supporting Template, Allignment And Leveling For Exact Location Of Stubs Of Stub Setting Template, Dismantling Of Template After Completion Of Initial Curing Of Cement Concrete, Movement Of Template From One Location To Another Complete, As Directed By Board Staff. - General Area (For 110 Kv Multi Circuit Towerswt Of 110 Kv Mc/ Wt Of 110 Kv Dc (1.027/.533)Xa1) , Transport Of Materials Issued Departmentally For The Worksform Departmental Stores And Distribution To Locations For Erection Including Storageif Necessary, Loading And Unloading Charges Etc As Directed By Board Staff. - General Area 1.Line And Earth Conductors Upto 10 Km , Line And Earth Conductors Above 10 Km (Additional Charges) , Insulators And Accessories, Power Conductor Accessories, Earth Conductor Accessories Etc.Upto 10 Km , Insulators And Accessories, Power Conductor Accessories, Earth Conductor Accessories Etc.Above 10 Km (Additional Charges) , Towers, Extensionsand Other Stru Ctures And All Other Materials Includi Ng Earthing Materials Etc.Upto 10Km , Towers, Extensionsand Other Structures And All Other Materials Including Earthing Materials Etc. Above 10 Km (Additional Charges) , Erection Of Tower Super Structure Above Ground Levelincluding Erection Of Normal And Special Hill Side Extension Members Wherever Necessary, Providing Tower Accessories Like Phase, Danger And Number Plates, Bird Guards, Anti Climbing Devices, Including Tighting ,Punching And Tack Welding Upto Bottom Cross Arm In The Bolt And Nutafter Punching And Applying Zink Rich Primer Wherever Necessary Etc. Complete, As Directed By Board Staff (For 110 Kv Dc Tower - Average Height Is 22 Mtrs) General Area , Erection Of Tower Super Structure Above Ground Levelincluding Erection Of Normal And Special Hill Side Extension Members Wherever Necessary, Providing Tower Accessories Like Phase, Danger And Number Plates, Bird Guards, Anti Climbing Devices, Including Tighting ,Punching And Tack Welding Upto Bottom Cross Arm In The Bolt And Nutafter Punching And Applying Zink Rich Primer Wherever Necessary Etc. Complete, As Directed By Board Staff110 Kv Mc Tower ( (A1) X1.91) Average Height 42 M , Providingearthing In Terminal Tower As Per Standard Specificationby Providing 150Mm Diabore Hole For A Depth Of 3.6M And Placing Of Gi Pipes 50 Mm Dia Gi C Class 3M Long Into The Bore Including Cost Of 600 Mm Dia Rcc Collar Placing Over The Earth Pipe And Connecting The Earth Pipe And Tower Leg Using7/3.66 Mm Gi Earth Wire Withlugsconnecting To The Pipeand Fixing Necessary Gi Clampetc., Includingdrilling Of Bore Cost Of All Lead And Lifts Etc., Complete. , Manufacturing, Testing & Supply Of 48 Fibre Opgw -Aslh-D(S)B 48Smf (A250a 79-6.4) Complete In All Respect As Per Scope And Technical Specifications , Manufacturing, Testing & Supply Of Hardware Set For 48 Fibre Opgw Ofc Including Cable Fittings And All Accessories Complete In All Respect As Per Scope And Technical Specifications , Manufacturing, Testing & Supply Of Joint Box (48 Fibre)( One Joint Box After 4 Km) Complete In All Respect As Per Scope And Technical Specifications , Manufacturing, Testing & Supply Of Fodp 48 Fibre For48 Fibre Opgw -Aslh-D(S)B 48Smf (A250a 79-6.4) Complete In All Respect As Per Scope And Technical Specifications , Installation Of Unarmoured Under Ground Optical Fibre Cable (Ug Ofc 24 Fibre Dwsm)At 110Kv Substations Through Existing Cable Trench By Removing Concrete Slab,Installation Of Hdpe Pipe Etc.., Preinstallation Test (Drum Test),Post Installation Test,Splicingand Link Test (End To End) And Placing Back Concrete Slabs As Good As In Original Condition. , Installation,Testing And Commissioning Of Fodp 48 Fibre And Termination Of Ug Cable. , Supply Of Unarmoured Under Ground Optical Fibre Cable 24 Fibre Dwsm , Supply Of Plb Hdpe Pipe Including All Accessories For Ofc -Ug Cable , Supplygi Barbed Wire 12G 2 Ply (Tata Or Equivalent Make) At Site Including All Cost Of Materials, Labour For Loading, Transportation ,Unloading Etc Complete , Paving Out, Stringingand Tensioning As Per Standard One Opgw Including Fixing The Conductors On To The Tower Tops Using Tension Clamps And Suspension Clamps , Jumpering The Conductor At Tension Points , Jointing Of Conductor Where Ever Necessary, Erection Of Earth Bonds, Hire Charges D For Pulling Machines, Tractors And Stringing Tools, All Hire And Labour For Protective Trestles And Providing Suitable Back Strings At The Time Of Stringing Etc Complete. , Paving Out, Stringingand Tensioning Of Power Conductorsincluding Attaching Insulator Strings With Arcing Horns Or Ringson To The Tower Cross Arms, Clamping The Conductor To The Insulator Strings Usingsuspension Clampswith Armour Rods And Tension Clamps, Jumpering The Conductors At Tension Points, Jointing The Conductors And Pilot Wire Wherever Necessary, Installation Of Vibration Dampershire Charges Of Tractor And Stringing Tools, Etc. Complete. ( Base Data For Acsr Panther) , Drilling Of Holes , Filling Of Holes , Cutting Of Steel Angles , Providing Protection For Telephone Cables And Lines, Lt& Ht Oh Lines,Traction Lines,Buildings,Road And Railway Crossings Etc Beneath The Line By Providing Suitable Scaffoldings At The Time Of Stringing And Dismantling Of Lines.(Using 3Nos9m Long Arecanut Trees And 4 Nos, 6M Long Casurina Poles.) , Lowering Down The 11Kv (3 Conductor) Line From The Pole After Disconnecting Jumper Connection, Loosening Pin Bindings Wherever Necessary, Re-Tensioning The Same After Giving Jumper Connection, Pin Bindings Etc… After The Completion Of Eht Line Work. , Lowering Down The 3 Phase Lt Line With Neutral And Street Main If Any From The Post After Disconnecting Jumper Connection, Loosening Pin Bindings Whichever Necessary, Re-Tensioning The Same After Giving Jumper Connection, Pin Bindings Etc After The Completion Of Eht Line Work. , Lowering Down The Lt Single Phase Line With Neutral And Street Main If Any From The Post After Disconnecting Jumper Connection, Loosening Pin Bindings Whichever Necessary, Re-Tensioning The Same After Giving Jumper Connection, Pin Bindings Etc… After The Completion Of Eht Line Work. , Lowering Down The Three Phase /Single Phase Wpguy Wire Service From The Poles After Disconnecting And Redoing The Same, Giving Connections Etc... After The Completion Of Eht Line Work. , Providing Barricading Using Casuarina Poles Of 15Cm To 24Cm Girth Including All Charges For Providing1.25M Long Poles At 1.2M Intervals(15-20Cm Below Ground Level) And Providing Poles Horizontally At 3 Places And Tying Firmly, Providing Danger/Caution Boards At Frequent Intervals, Painting Posts, Providing Lighting Arrangements During Night And Taking All Necessary Precautions As Per Standards Etc. Complete As Per Directions Of Departmental Officers At Site. , Sorting Of Tower Parts, Bolts,Nuts Of Various Sizes At Site.Etc Complete. , Removal Of Temporaray Island Formed For The Work By Excavation Of Earth By Mechanical Means And Removal By Cart And Lorry - Wherever Required As Per The Site Conditions, Requirement Of Land Owners Of The Location.
Contract Date : 21 Dec, 2022   |   Contract Value : 11.50 Crore
BRR : 9336524 RATE CONTRACT FOR UPKEEP / MAINTENANCE OF EXISTING 33/11 kV RECEIVING STATIONS ALONG WITH THEIR 33 kV LINES AND FABRICATION & HANDLING OF MATERIAL OF DIVISIONAL STORE UNDER THE JURISDICTION OF SUB-TRANSMISSION DIVISION-I, JPDCL, JAMMU FOR THE YEAR2025-26- 1 Erection of 16 mtr long Steel Tubular Pole with planting depth of 1/6 th of the height of the pole including digging of pits, disposal of extra earth, collection of boulders and filling back. 2 Erection of 13 mtr long Steel Tubular Pole with planting depth of 1/6 th of the height of the pole including digging of pits, disposal of extra earth, collection of boulders and filling back. 3 Erection of 11 mtr long Steel Tubular Pole with planting depth of 1/6 th of the height of the pole including digging of pits, disposal of extra earth, collection of boulders and filling back. 4 Erection of 9 mtr long Steel Tubular Pole with planting depth of 1/6 th of the height of the pole including digging of pits, disposal of extra earth, collection of boulders and filling back. 5 Erection of 13 mtr long PCC Pole with planting depth of 1/6 th of the height of the pole including digging of pits, disposal of extra earth, collection of boulders and filling back. 6 Erection of 11 mtr long PCC Pole with planting depth of 1/6 th of the height of the pole including digging of pits, disposal of extra earth, collection of boulders and filling back. 7 Erection of 9 mtr long PCC Pole with planting depth of 1/6 th of the height of the pole including digging of pits, disposal of extra earth, collection of boulders and filling back. 8 Painting of 16 mtr long Steel Tubular Poleincluding fixtures with one coat of red-oxide and two coats of silver(aluminium) paint 9 Painting of 13 mtr long Steel Tubular Poleincluding fixtures with one coat of red-oxide and two coats of silver(aluminium) paint 10 Painting of 11 mtr long Steel Tubular Poleincluding fixtures with one coat of red-oxide and two coats of silver(aluminium) paint 11 Painting of 09 mtr long Steel Tubular Poleincluding fixtures with one coat of red-oxide and two coats of silver(aluminium) paint 12 Cement Bottoming (U/G,A/G) in 1:3:6 mix including excavation and form work, (16/13/11/9 Mtr Long Poles (Complete Job) 13 Fixing of Galvanisedspiral Earthing of SWG No. 8,G.I wire of 115 turns confirming to REC-J1 construction standard, (J1) 14 Fixing of 66/33KV Galvanised Guy Set (Guy wire, Guy Rods, Turn Buckle plate ,Guy Insulators) confirming to IS 2141 / 1979 or the latest version thereof including digging of pits & refilling 15 Collection of Snapped ACSR Cond. and Re-stringing, tensioning , binding of ACSR Conductor, (100mm2 ACSR Conductor) 16 Collection of Snapped ACSR Cond. and Re-stringing, tensioning , binding of ACSR Conductor, (150mm2 ACSR Conductor) 17 Collection of Snapped ACSR Cond. and Re-stringing, tensioning , binding of ACSR Conductor, (200mm2 ACSR Conductor) 18 Dismantling of Steel Tubular Pole including carriage up to dumping site, (16 mtr. Long ) up to distance of 50 mtr 19 Dismantling of Steel Tubular Pole including carriage up to dumping site, (13 mtr. Long ) up to distance of 50 mtr 20 Dismantling of Steel Tubular Pole including carriage up to dumping site, (11 mtr. Long )up to distance of 50 mtr 21 Dismantling of PCC Pole including carriage up to dumping site, (11 mtr. Long )up to distance of 50 mtr 22 Dismantling of Steel Tubular Pole including carriage up to dumping site, (9 mtr. Long )up to distance of 50 mtr 23 Dismantling of PCC Pole including carriage up to dumping site, (9 mtr. Long )up to distance of 50 mtr 24 Dismantling of Three/Four pole structure, opening of channels, crossarms, angles(Complete Job.) 25 Dismantling of Two pole structure, opening of channels, crossarms, angles (Complete Job.) 26 Straightening of tilted Steel Tubular Pole (16 mtr. Long ) 27 Straightening of tilted Steel Tubular Pole (13 mtr. Long ) 28 Straighteningof tilted Steel Tubular Pole(11 mtr. Long ) 29 Straighteningof tilted PCC Pole(11 mtr. Long ) 30 Straighteningof tilted Steel Tubular Pole(9 mtr. Long ) 31 Straighteningof tilted PCC Pole(9 mtr. Long ) 32 Unloading of Steel Tubular Pole including carriage up to dumping site, (16 mtr. Long )up to distance of 50 mtr 33 Unloading of Steel Tubular Pole including carriage up to dumping site, (13 mtr. Long )up to distance of 50 mtr 34 Unloading of Steel Tubular Pole including carriage up to dumping site, (11 mtr. Long ) 35 Unloading of Steel Tubular Pole including carriage up to dumping site, (9 mtr. Long ) up to distance of 50 mtr 36 Loading of Steel Tubular Poles including carriage up to dumping site, (16 mtr. Long ) 37 Loading of Steel Tubular Poles including carriage up to dumping site, (13 mtr. Long ) 38 Loading of Steel Tubular Poles including carriage up to dumping site, (11 mtr. Long ) 39 Loading of Steel Tubular Poles including carriage up to dumping site, (9 mtr. Long ) 40 Extra carriage from dumping site, (16 mtr. Long )up to site of work Its 100 mtr 41 Extra carriage from dumping site, (13 mtr. Long )up to site of work Ist 100 mtr 42 Extra carriage from dumping site, (11 mtr. Long )up to site of work Ist 100 mtr 43 Extra carriage from dumping site, (9 mtr. Long )up to site of work Ist 100 mtr 44 Extra carriage of 9 Mtr PCC Pole beyond 100mtrs for every 50Mtr or part thereof in plain areas 45 Extra carriage of 11 Mtr PCC Polebeyond 100mtrs for every 50Mtr or part thereof in plain areas 46 Extra carriage of 9 Mtr PCC Pole beyond 100mtrs for every 50Mtr or part thereof in semi hillyareas 47 Extra carriage of 11 Mtr PCC Pole beyond 100mtrs for every 50Mtr or part thereof in semi hilly areas 48 Unloading of Steel of Sorts , (Steel) 49 Loading of Steel of Sorts , (Steel) 50 Unloadingof Conductor Reels, (100mm²/150mm²/200mm² ACSR Conductor)at site 51 Loadingof Conductor Reels, (100mm²/150mm²/200mm² ACSR Conductor) at site 52 Fixing of 33 kVDiscInsulator (70 KN)2008 standards, (Porcelain ) 53 Fixing of 33 kV Disc fitting (70 KN) 2008 standards, (Polymer) 54 Fixing of 33 kV Insulators (10 KN) standards, (Porcelain ) 55 Fixing of33 kV Pin Insulators (10 KN) suitable for 100/150/200mm² ACSR Conductor. 56 Replacement/Fixing of 33 kVTension fittings (Socket & Ball type or T&C Type) for ACSR 57 Replacement/Fixing of 33 kV Tension fittings (Socket & Ball type or T&C Type) for ACSR 150m² 58 Replacement/Fixing of 33 kVTension fittings (Socket & Ball type or T&C Type) for ACSR 200m² 59 Straighteningof X-arms of different sizes (100x50x50x6 mm channel Iron,50x50x6mm Angle Iron ) duly painted with one coat of red-oxide and two coats of silver paint fixing with different sizes and sorts of nuts,bolts and washers, (Channel Iron X-arms, Angle Iron-X-arms, Pole Tops) 60 Straighteningof angle ironof different sizes (65x65x6 mm channel Iron,50x50x6mm Angle Iron 61 Repair and re-erection of Cradle for guard netting with GI wire 8 No including wire binding, cutting /bending of GI Wireas per REC standards 62 Branch cutting of 33 kV lines 63 Removing of wild climbers/vegetation around 33 kv Poles 64 Removing of wild climbers/vegetation around 33 kV Tower 65 Removing of wild climbers from top of 33 kV Lines. 66 Removing of wild climbers from Peak, cage, cross arm of 33 kV old tower Line 67 Patrolling of 33 kV Line(Routine/Under fault) 68 Tightening of loose guys 69 Dismantling & re-erection of damaged guys including digging of pit & refilling the same 70 Replacement of damaged Disc insulator in tension string 71 Replacement of cross arms of sizes 100x50x6 72 Replacement of angle iron of sizes (65x65x6, 50x50x6) 73 Replacement of Pin insulator on Four/Three/Double Pole Structure 74 Replacement of Pin insulator on Single Pole Structure 75 Replacement of Worn-out/Damaged Jumper of 33 kV Towerlines 76 Replacement of Disc Insulator, Suspension Fitting of 633 kV Towerlines 77 Replacement of worn-out/Loose/Damaged Jumper of 33 kV lines (sets of3 Nos) 78 Local earthing of 33 kV Lines by way of using discharge/earth rods at faulty site to avoid accident due to any induction while working on Line. 79 Tightening / restringing of loose ACSR Dog 100 mm2 80 Tightening / restringing of loose ACSR Wolf 150 mm2 81 Tightening / restringing of loose ACSR Panther200 mm2 82 Dismantling & Re-erection of ACSR Dog 100mm2 including collection of dismantled conductor , making of small bundles and its carriage 83 Dismantling & Re-erection of ACSR Wolf 150mm2 including collection of dismantled conductor , making of small bundles and its carriage 84 Dismantling & Re-erection of ACSR panther 200mm2 including collection of dismantled conductor , making of small bundles and its carriage 85 Dismantling of stay sets complete 86 33 KV VCB Repairs & Renovationby way of a) Setting of Mechanical Assembly / Replacement of damaged spring / Repair of locking & charging system 87 b) Replacement of Tripping Coil/Closing coil 88 c) Replacement of Damaged Vacuum Interrupter 89 d) Replacement ofBushing including Clamps 90 33 kV C&R Panel: Replacement of different equipmentsa) Ammeter, Volt Meter Indication , Lamps, Fuses, Trip Close Switch ,Selector SwitchIdentification of Panel Wiring Faults & its rectification 91 b) Replacement of Different Relays - MITNumerical Relay / Electro-mechanical relay / Master Trip Relay/ Differential Relay/Auxiliary Relay etc. 92 Installation, Testing, commissioning of 66-33 kV Control Relay Panels (Complete Job) 93 Complete testing of Relays Setting of Testing Kit, Interconnection between various points of panel with respect tosecondary injection key on various current taps, recording the observation thereof. All modifications necessary to achieve desired results. 94 Control Cable Replacement of damagedControl Cables of all typesincluding binding with PVC Belts/ Binding Wire, Peeling of insulation and fixing of proper size thimble connecting the cable after identification of each core to both ends i.e. Panel to CTs / panel toPTs /panel to Breaker and Making functional of 33 KV Outdoor Breakers, Protection , Alarms, Annunciation (complete Job) 95 Upkeep of earthing of aux. transformer 96 Upkeep of earthing of Power transformer 97 Upkeep of earthing of 33/11 kV LA 98 Providing of extra earthing for improvement purpose (complete job) 99 Upkeep of earth mat of out door yard 100 Replacement of damaged earth mesh in Sub-Station as per approved Map & Design. 101 Excavation of trenches of 0.6 Mtr Depth and 2.0 Mtr wide mtr in normal soil / hard soil 102 Repairing / Laying of MS Flat and MS Rod in deep excavated trench and welding of MS Flat & MS Rod with Mesh. 103 Repairing of Earthing with Spikes of MS Rod 20mm, 3 Mtr in Length as per REC Drawing 104 33/11 KV Power Transformera) Opening of Transformer Tank Top Cover to prevent oil leakage from top(if required to facilitate maintenance of transformer after removing the required accessories), ,Draining/ Re-Filling of required Oil, Change of gaskets of valves/ radiators/ Buchholzs relay radiators valves of power transformer of capacity: 3.15 MVA to 10 MVA 105 b) Replacement of silica gel 106 c) General Inspection by through inspection of each individual parts, Ratio test by applying voltage on HV Side and measuring LV Voltage on various Tap Positions, checking of Buchholz relay, Surge relay conservator, sensors, measurement of 1R-Value dialectic strength of oil, cleaning of Power Transformer etc 107 d) Replacement of any one of the following i.e. temperature indicators, gas operated Buchholzs relay, oil temperature indicator, winding temperature indicator etc 108 e) Preventing of leakage by changing main gaskets after removing the old gasket, Replacement of HV/LV Busing & Bush Rod,Ring and Rubber Washers (complete job to prevent leakages) 109 f) Cleaning of Scale deposited over the body and radiators of the power transformer with thinner/ detergent and de-rusting in perfect manner.(routine work) 110 g) Cleaning of LV/HV bushings of Power Transformer(routine work) 111 h) Replacement of Bus Bars ofPower Transformer 112 i) Replacement of LV/HV clamps of Power Transformer 113 Oil Topping of Power Transformer 10 MVA 114 Oil Topping of Power Transformer 4 MVA to 6.3 MVA 115 Oil Topping of Power Transformer 3.15 MVA 116 Recording of IR values of transformers 117 Installation, Testing and Commissing of Power Transformer 66-33/11 KV Installation of LV/HV Bus Bars with proper care, of transformer for any leakagecommissioning of Power of Transformers by applying low voltageapproximately equal to impedance voltage on HV Side and short circuiting the LV terminals, Energizing the transformer by applying required primary voltage to it & keeping the transformer on no load to observe the behaviour of transformer, setting on 25% of the load on the transformer for a period of at test 6 hours and observation of oil including temperature, increase the transformer is fully loaded and topping of oil.a) 10 MVA 118 b) 6.3 MVA 119 c) upto 5 MVA 120 Checking and tightening of Jumpers, Droppers in 66/33 KV Outdoor Yard 121 Replacement of T/PG clamps 122 Replacement of Disc insulators including its hardware. 123 33 KV LA & 11 KV Stn. Type LAReplacement of 66 KV,33 KV & 11 KV Lightening Arrestor including jumpering and earth connecting in all respect. a) 66 KV LA 124 b) 33 KV LA 125 b) 11 KV LA 126 Separate pipe Earthing / G.I Rod earthingas per REC Drawing J.2 127 Replacement of pipe earthing / Rod earthing with new one 128 Installation, testing and Commissioning, replacement of 66 KV Isolators 129 Installation, testing and Commissioning,replacement of 33 KV Isolators 130 Replacement of11 KV Isolators 131 Repair & Renovationof 66/33 KV and 11 KV isolators including setting right its alignment for proper operation, lubrication/greasing of jaws, bearings operatings handle etc(complete job) 132 Replacement of worn-out/heated Pad clamp/Isolator clamps of 66/33/11 kV Isolator by way of dismantling. Drilling of holes on new and fixing (complete job) 133 Repair & Renovationof Isolator Jaws 66/33 KV and 11 KV isolators.(complete job) 134 Replacement of post insulator / tendon pipes/ operating box by way of dimentalling, necessary fabrication where ever required for proper operation of 66/33/11 kv Isolators. 135 33 KV CTsInstallation, testing and Commissioning of 33 kV CTs ( of all ratios )Complete Job 136 33 KV CTsRepairs & Renovation of 33 KV CTs by way of replacing shorting strips, connecting rod, transformer oil, damaged insulator (CTs of all ratios) 137 Replacement of 33 KV Outdoor Type CT of different ratio and dismantling of damaged CT(CTs of all ratios) 138 Oil Topping of 66/33 kV CT & PT by way of opening of top cover and refixing with new gaskets if necessary and preventing of oil leakages if any.(complete job) 139 66-33 kV PTsInstallation, testing and Commissioning of 66-33 kV PTs (complete job) 140 66 kV PTsReplacement of 66 KV Outdoor Type PT and dismantling of damaged PT, dragging to installation/loading site, lifting from ground to steel structure. 141 33 kV PTsReplacement of 66 KV Outdoor Type PT and dismantling of damaged PT, dragging to installation/loading site, lifting from ground to steel structure 142 Cleaning of porcelain bushing, tightening ofPT/CT clamps, derusting & painting of body of 33 kV PTs & CTs 143 Tightening of nuts & bolts, replacement of oval thread bolts, chipping by way of welding to the bolts after tightening in a single bay 144 Painting with mix red oxide paint two coats of approved make on steel works after cleaning with wire brush/ sand paper 145 Painting of steel structure erected in outdoor yard with aluminium paint two coats with approved brand andfixture to given an even surface 146 Battery Banka) Repair & maintenance of battery set including maintaining specific gravity, electrolyte level, cleaning, checking, tightening of battery terminals in all respects it includes measuring voltage of each battery. 147 b) Tightening of all nut and bolts, replacement of damaged battery cells 148 c) Installation, testing and Commissioning of Battery Bank (complete Job) 149 Battery ChargerRepair/Renovation battery charger for proper functioning by way of replacement of rectifier unit, Ammeter, Voltmeter, MCB,Cooling fan, LED indications, buzzer alarms for OV/UV etc (Complete Job) 150 Repair and maintenance of DC Board, identification of fault in respect of cableand its replacement, replacement of damaged MCCB, Kit Kat, Bus Bar & other allied job. 151 Repair and maintenance of AC Board, identification of fault in respect of cableand its replacement, replacement of damaged MCCB, Kit Kat, Bus Bar & other allied job. 152 Installation, testing and Commissioning of Battery Charger (complete Job) 153 Deweeding of vegetation in outdoor yardRemoving of stone metal, deweeding of unwanted vegetation, spreading of stone metal collected earlier for removal of vegetation, levelling the area with existing stone metal 154 Providing of additional stone metal and its carriage and laying in outdoor yard, this including breaking of stones complete job. 155 Cleaning of Control Room, removing dirt & dust from the panels, walls, cleaning of fixtures (for one bank) 156 Painting of internal/external walls and roof by approved brand of oil based distemper 157 Painting of door and window panels of control room by approved brand of paint 158 Repairs & Renovation of 11 KV VCB,by way of replacement of a) Grid-spout assembly 159 b)Replacement of damaged CTs of different ratio Testing the CT with the help of primary injection set fixing in pannel, fixing the secondary connection after assessing the load (complete job) 160 c)Thorough checking of control wiring circuits, replacement of damaged wire if any, replacement of terminal plates, tripping circuits, close/ trip switch, ammeter switch, replacement of voltmeter & ammeter . 161 d) Replacement of 11 KV damaged PT 162 e) Replacement of blown fuses, checking the PT terminal with respect of 11 KV bus bar complete job. 163 f) Replacement of Trip/Close coil 164 g) Replacement of Trivector meter on 11/33/66 kV Panels 165 Installation, testing and Commissioning , replacement of LT cabele 166 11 KV Power Cables / 33 KV Power cables/66 KV Power cablesa) Identification of damaged portion of cable, tracing of cable, remove cable from trench, carriage and laying of cable(complete job) including cleaning of cable trenches. 167 b) Replacement of damaged cable of sizes 168 Replacementof termination kits of different sizes, connecting the cable with panel and outgoing structures after crimping of lugs fixing with nuts and bolts, checking of earth point, connecting the earthing point of cable with existing earthing system a) 11 KV Indoor Termination Kit (1-Phase/ 3 phase) 169 b) 11 KV Outdoor Termination Kit (1-Phase/ 3 phase) 170 c) 33 KV Indoor Termination Kit (Single Phase) 171 d) 33 KV Outdoor Termination Kit (Three Phase) 172 e) 33 KV Indoor Termination Kit (Three Phase) 173 f) 33 KV Outdoor Termination Kit (Single Phase) 174 Improvement of earthing system in control room by way of replacement of earthing risers from earthing point to panel / checking of all welding points/ re-welding of lose connection, laying of fresh / additional earth-mat strip to improve the existing earthing system (Complete one Panel set) 175 Checking of IR values 176 De-watering of receiving station to avoid water logging. 177 Repairing of electrical circuits for improvement of control room immunination, power points etc (Complete Job) 178 Installation, Testing, commissiing for replacement of Aux. Transformer at receiving station 179 On site repairing of aux transformer for missing phase, LT strip, LT bush rod, LT bush cup, HT bush rod etc (Complete job) 180 Transport charges for carriage of T&P, men & material on urgent basis during power breakdown and restoration of system. (auto carrier) aditional 1km @ 90/per km 181 Replacement of out door yard lights including wiring system and fixing oflamps on fixtures. 182 Marking of equipments, sign boards by way of painting/fixing of PVC plates for demarcation of different equipment to avoid mishandling. 183 Replacement/repair/fixing of ceiling fans at Receiving station. 184 Replacement/repair/fixing of cooling fans on radiators of power transformer to avoid heating. 185 Flash in 66KV,33 KV & 11 KV Panels due to overloading moisture, Cleaning of carbonized panel by petrol / cotton cloth, replacement of damaged / worn-out lugs, post insulator, Bakelite sheet, arcing chamber panel heaters etc. 186 Repair of plaster of thickness 12 mm to 20 mm in patches of areas 2.5 sqm meters and under including cutting the patch in proper shape and preparing and plastering the surface of the walls complete incl. disposal of rubbish to the dumping ground within 50 M leada) with Cement mortar 1:4 (1 cement : 4 fine / coarse sand) 187 Cutting of large tree branches falling over 33/11 lines and coming into the corridor to avoid damages/ faults/conductor snapping. 188 Cleaning of cable duct, removing of duct covers and placing back after cleaning the duct including disposal of rubbish up to 50 Mtr lead 189 Replacing sand store slabs in roofing, laid incement mortar 1:4 (1 cement : 4 coarse sand) including necessary repairs and cement painting with same mortar complete, including disposal of rubbish to dumping ground within 50 Meters of lead 190 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chow khats, holdfast etc. Complete and stacking with 50 Mtr lead 191 Providing and fixing T-iron frames for doors, windows and ventilators of mild steel T-sections, joints mitred and welded, including fixing of necessary but hinges and screws and applying a priming coat of approved steel primer (CC 1:3:6) 192 Demolishing cement concrete manually / by mechanical means including disposal of material within 50 Mtr 193 Cement concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 graded Stone aggregate)62 mm thick 194 Roof top treatment to prevent water leakage of control room 195 Repairing of receiving station mesh fencing / Chain link mesh fencing height upto 8ft 196 Watering of earth pits 197 Cleaning/washing of solar panels & batteries 198 Cleaning of ACDC,DBDC Board, RTCC, Charger, Battery Bank, Solar batteries, other alike small equipments (complete Job) 199 Cleaning of 33 kV CRP using vacuum cleaner from inside with proper care, from outside with thinner/varnish and making 33 kV CRP Vermic Proof. 200 Cleaning of 11 kV Panel using vacuum cleaner from inside with proper care, from outside with thinner/varnish and making it Vermic Proof to avoid rodent faults. 201 New 33 KV Line Fabrication , erection and painting of 15 Mtr long 33 KV Self supporting tower structure for crossing of road 202 Laying of foundation for 33 KV self supporting Tower Structure 15 Mrs. long including setting of stubs complete job 203 Erection of Channel cross arm of size 100X50X 6mm ,10 feet long and above including fixing of MS flat iron clamps with required size of bolts including punching of bolts complete 204 Erection of Channel cross arm of size 100X50X 6mm up to 09 feet long including fixing of ms flat clamps with required size of bolts including punching of bolts complete 205 Erection of Angle Iron Braces of size 65X65X6 mm,fixing with double clamp of MS Flat including punching of bolts of Ist level to level 3rd in cross section typeabove up to 14longcomplete 206 Erection of Angle Iron Braces of size 65X65X6 mm along with belts of same size ,fixing with double clamp of MS Flat including punching of bolts of Ist level to level 3rd in cross section type 6 and above upto 10longcomplete 207 Erection of Angle Iron belts of size 50X50X 6 mm along with belts of same size ,fixing with double clamp of MS Flat including punching of bolts of Ist level to level 3rd in cross section type upto 10 long 208 Erection of Angle Ironof size 65X65X6 mmfixing with double clamp of MS Flat including punching of bolts of Ist level to level 3rd in crossection typeabove11 long complete for guardnetting. 209 Flat iron ties 50x6 mm size 1 feet long along with fixing with cross arms 210 Erection of 33 KV Disc insulator (polymer type )with tension fittings including punching of locking pinscomplete 211 Erection of 33 KV Pin insulator with pins3 nos on top of cross arm including fixing of MS Flat Ties to rest it on , punching of base bolt /locking pin complete 212 Erection of Guy rodincluding digging of pit , Disposal of excavated soil ,refilling of excavated pits in layers of stone boulders and fine soil including fixing , adjusting properly Turn Buckle, Anchor Plate and staining screw complete 213 Carriage at site , un-bundling , Laying and stringing of ACSR DOG Conductor including making of small bundles of conductor as per site requirement, cutting in required span lengths complete (AS PER REC STANDARD) 214 Erection of anti climbing Devices at ST pole along with fixing /cutting /bending of Barbed wire, fixing with clamps 215 Erection of Danger plates 216 Route /temp path clearance by way of cleaning bushes and vegetation & making temp. pathcutting & filling for carriage of line material ( 400 mx1mx0.2m)= 80 cum 217 Watch and ward of the material and T&P round the clock i.e. 3 shifts, Rate of 1 Lab for 1 Shift 218 Route clearance for corridor of 5 m 219 Installation, testing and Commissioningof 3.15 MVA , 33/11KV Power Transformer (new work) 220 Installation, testing and Commissioning of 5 MVA& 6.3 MVA , 33/11 KV Power Transformer 221 Installation, testing and Commissioningof 10 MVA , 33/11KV Power Transformer 222 Installation, testing and Commissioning of 11kV Panel Borad with VCB Incomer(one no.) 223 Installation, testing and Commissioning of 11kV Panel Borad with VCB outgoing(one no.) 224 Setting of stubs with templates after positioning and leveling of templates excluding cost of foundations 225 Handling and Fabrication of Material in Divisional Store, Fabrication of Angle iron braces/belts /guard netting angles,fencing posts etc from angle iron of sizes 226 Fabrication of guy rods complete including turn buckle, staining screw, anchor plate, thereading of guys and staining screw 227 Fabrication of channel cross arms of sorts from MS channel of sizes , Making holes as per requirement,Punching of members and numbering on each member,Grinding of sharp edges and uneven surface of memebers and painting of members with red oxide paint. 228 Fabrication of ties, clampsfrom MS flat ( suitable for 9 mts, 11mts, and 13mts poles) 229 Fabrication of earthing plates , cable duct coversfrom MS plate as per REC drawings 230 Fabrication of earthing spikes from MS Tor steel of sorts as per REC drawings 231 Fabrication of ST poles by way of drilling of extra holes 232 Fabrication of foundation boltsfrom MS Tor steel of sorts including threading as per REC drawings 233 Fabrication of earthing pipe from GI pipe and welding of earthing plateas per REC drawings 234 Fabrication of column structures, beam structure, isolator structures,LA ,CT,PT and PI Structures as per REC drawings 235 Shifting of channel/Angle /Flat iron at and average distance of 50mtr from unloading site to site of stacking and stacked properly. 236 Shifting of channel/Angle /Flat iron/fabricated material at and average distance of 50mtr for making space for other store material and its stacking . 237 Unloading of ST poles 9mtr in divisional store 238 Unloading of ST poles 11mtrin divisional store 239 Unloading of ST poles 13mtrin divisional store 240 Unloading of ST poles 16mtrin divisional store 241 Unloading of PCC Poles 9/8 mtr . in divisional store 242 Unloading of PCC Poles 11 mtrin divisional store 243 Unloading of PCC Poles 13 mtr in divisional store 244 Dragging/shifting of PCC/ST Pole at and average istance upto 50 mtr for stacking to accesible place for loading/unloading purpose and its satacking 245 Unloading of ACSR Conductor dogin divisional store 246 Unloading of ACSR Conductor wolfin divisional store 247 Unloading of ACSR Conductor pantherin divisional store 248 Shifting of Old/New ACSR Conductor at and average distance of 50mtr for unloading site to site of stacking and stacked properlyand also for making space for other store material and its stacking .. 249 Unloading of 11KV VCB pannels (1+3) 250 Unloading of 11KV VCB pannels (1+4) . 251 Unloading of 11KV VCB pannels (1+5) . 252 Unloading of 11KV VCB pannels OK/Damage(1no) . 253 Unloading ofAC Board/DC Board/Battery bank/ Battery charger 254 Unloading of 33 VCB /C&R Pannel . 255 Shifting/ draggingof 11/33/66kv panel at an average distance of 50mtr for making space for other store material and its stacking also for making space for other store material and its stacking . 256 Unloading of XLPE Cable 120/185 mm² . 257 Unloading of XLPE Cable 240/300 mm² . 258 Unloading of XLPE Cable 400/630 mm² . 259 Shifting of XLPE Cable all sizes at an average distance of 50mtr from unloading site to site of stacking and stacked properly also for making space for other store material and its stacking ... 260 Unloading of 66/33/11 KV Cable kits of different sizes 261 Shifting of 66/33/11 Cable kits of all sizes at an average distance of 50mtr from unloading site to site of stacking and stacked properly also for making space for other store material and its stacking ... 262 Unloading of Guy/GI wire/Barbed wire including carriage towards stacking site and stacked porperly. 263 Unloading of Power Transformer 3.15/4 MVA New/damage . 264 Unloading of Power Transformer 5/6.3MVA New/damage . 265 Unloading of Power Transformer 10 MVA New/damage . 266 Unloading of 11KV New/damage DistributionTransformer. 267 Dragging of 3.15/4 MVA New/damage Transformer at an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and its satacking 268 Dragging of 5/6.3 MVA New/damageTransformer at an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and its satacking 269 Dragging of 10 MVA New/damage Transformer at an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and its satacking 270 Dragging of 11kv Transformer at an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and its satacking 271 Unloading ofTransformer oil Barrels. 272 Dragging ofTransformer oil old/ new barrel at an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and its satacking also for making space for other store material and its stacking .. 273 Unloading ofMS Angle, MS Channel, MS flate ,tar steel 274 Unloading of hardware items such as nuts and bolts , clamps of sorts, washers,welding rods,old sarees,chain link mesh,pipe etc . 275 Shifting ofhardware items such as nuts and bolts , clamps of sorts, washers,welding rods,old sarees,chain link mesh,pipe etc at an average distance of 50mtr for making space for other store material and its stacking . 276 Unloading of 33/11 KV Dics insulators. 277 Unloading of 33 KV Dics fittings 278 Shiftingof 33/11KV disc insulator at an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and its satackingalso for making space for other store material and its stacking .. . 279 Unloading of 33/11 KV Pin insulators/Guy insulator /G.I Pin. 280 Shiftingof 33/11KV pin insulator /guy/G.I Pinsat an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and also for making space for other store material and its stacking. 281 Unloading of Cement. 282 Shiftingofcement/cement block at an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and also for making space for other store material and its stacking ... 283 Unloading of 33 KV CT/PTUnit . 284 Shifting of 33 KV CT/PT at an average distance of 50mtr for making space for other store material and its stacking . 285 Unloading of 11 KV CT/PTUnit includingcarriage towards stacking site and stacked porperly. 286 Shiftingof 11 KV CT/PTat an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and also for making space for other store material and its stacking .. 287 Unloading of 33 KV Isolators. 288 Shiftingof 33KV Issolatorsat an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and its satackingand also for making space for other store material and its stacking . . 289 Unloading of 33/66 KV LAs. 290 Shiftingof 33/66KV LAsat an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and also for making space for other store material and its stacking . 291 Unloading of 11 KV LAs/GO/HG/issolator . 292 Shiftingof 11 KV LAs/GO/HG/issolator at an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and also for making space for other store material and its stacking .. 293 Unloading of PVC Cable /Control cable of different sizeincludingcarriage towards stacking site and stacked porperly. 294 Unloading of AL Paint /Red oxide paint/ Black paintincludingcarriage towards stacking site and stacked porperly. 295 Unloading of T&P Items like Drilling machine,chainPully ,Pully lifting machine ,Hand drill machine,AL ladder,welding set,tool kit,crimping tooletc 296 Unloading of Testing equipments like Meggar, Earth resitivitytester , Oil testing machine,Search Light, Turn ratio meter , multimeter etc . 297 Unloading of Safetyequipments like Safety belts, Safety shoes, Fire Extinguisher,Hand gloves, Yard lights , LED Bulbs , Rubber mat , etc 298 Shiftingof T&P /Testing / Safetyequipments at an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and also for making space for other store material and its stacking .. 299 Unloading of Filter plant heavy duty 300 Shiftingof Filter plantat an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and also for making space for other store material and its stacking . 301 Loading of PCC Poles 9/8 mtr 302 Loading of PCC Poles 11 mtr 303 Loading of PCC Poles 13 mtr 304 Loading of ST poles 9mtr 305 Loading of ST poles 11mtr 306 Loading of ST poles 13mtr 307 Loading of ST poles 16mtr 308 Loading of ACSR Conductor dog 309 Loading of ACSR Conductor wolf 310 Loading of ACSR Conductor panther 311 Loading of Cement 312 Loading of 11 KV VCB 1+3 Pannels 313 Loading of 11 KV VCB 1+4 Pannels 314 Loading of 11 KV VCB 1+5 Pannels 315 Loading of 11 KV VCB 1 Pannel OK/Damage 316 Loading of AC Board/ DC Board/Battery charger /Battery bank 317 Loading of 33KV VCB 318 Loading of 33KV C&R Pannels 319 Loading of XLPE Cable 120/185 mm² 320 Loading of XLPE Cable 240/300mm² 321 Loading of XLPE Cable 400/630 mm² 322 Loading of Cable kits of different sizes 323 Loading of Guy/GI wire/Barber wire 324 Loading of Power Transformer 3.15/4.0 MVA 325 Loading of Power Transformer 5.0/6.3 MVA 326 Loading of Power Transformer 10 MVA 327 Loading of 11 KV DistributionTransformer 328 Loading of Transformer Oil barrels 329 Loading of MS Angle iron braces, MS channel cross arms, Guy rod, Earthing spikes, MS Flate 330 Loading of hardware items such as nuts and bolts, clamps of sorts,washers,welding rods,old sarees,chain link mesh,pipe 331 Loading of 33 /11KV Disc insulator 332 Loading of 33 KV Disc fitting 333 Loading of 33/11 KV Pin insulator /Guy insulator /G.I Pin 334 Loading of 33 KV isolator 335 Loading of 33 KV LA 336 Loading of 11KV Isolators 337 Loading of PVC Cable /Control cable of different size includingcarriage from stacked site. 338 Loading ofAL Paint /Red oxide paint/ Black paint 339 Loading ofFilter plant heavy duty 340 Carriageof Fabrication column structures, beam structure, isolator structures,LA ,CT,PT and PI Structures etc towards stacking site and stacked properly 341 Loading ofFabrication column structures, beam structure, isolator structures,LA ,CT,PT and PI Structures etcincludingcarriage from stacked site. 342 Loading of 33 KV CT/PT units 343 Loading of 11 KV CT/PT units 344 Loading of T&P Items like Drilling machine,chainPully ,Pully lifting machine, Hand drill machine,AL ladder,welding set,tool kit,crimping tooletc units 345 Loading of Testing equipments like Meggar, Earth resitivitytester , Oil testing machine,Search Light, Turn ratio meter , multimeter etc units 346 Loading of Safetyequipments like Safety belts, Safety shoes, Fire Extinguisher,Hand gloves, Yard lights , LED Bulbs , Rubber mat , etcunits 347 Shifting of allied materials for making space for porper stacking of material 348 Carriageof Fabrication material from fabrication site towardsstacking site and proper stacking of material. 349 Repair of store shed by way of replacement of damaged CGI sheets, repair of CGI sheets by way of welding, replacememt of hooks, nuts and bolts, tightening of nuts bolts and hooks and welding . 350 Collection andcarriage of T&P items to working site and back crriage of T&P after job 351 Sorting of material by way of weighing / measuring and inspection of material and then carriage from weighing / measuring and inspection site to site of fabrication 352 painting of store shed with red oxide/Al paint single coat 353 Checking/Measuring/ Inspection/Meggering ofXLPE Cable/Control cable by way of unreal and after work agian rereelingon drum 354 Checking/Measuring/ Inspection ofACSR Conductorby way of unreal and after work agian rereelingon drum 355 Complete testing/ispection of pannels including relay testing , interconnection,charging polarity etc during issue/receipt/verification. 356 Prototype errection of Gantry /Beam/CT/PT/Isolator sturcture 357 Dismentling of ACSR Dog Conductor 358 Dismentling of ACSR Wolf Conductor 359 Dismentling of ACSR Panther Conductor 360 Dismentling of 3.15 MVA, 33/11 KV Power Transformer including dismentling of Cables, Radietors, drainage of Oil and filling in empty Barrels 361 Dismentling of 6.3 MVA, 33/11 KV Power Transformer including dismentling of Cables, Radietors, drainage of Oil and filling in empty Barrels 362 Dismentling of 10 MVA, 33/11 KV Power Transformer including dismentling of Cables, Radietors, drainage of Oil and filling in empty Barrels 363 Dismentling of 11 KV Panel Board with VCB (Incommer) 364 Dismentling of 11 KV Panel Board with VCB (Outgoing) 365 Installation of SMPS & CMR on Smart Meters 366 Installation/Replacement of Smart Meters
Contract Date : Ref. Documents   |   Contract Value : Ref. Documents
Disclaimer

We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.

Tender Detail
Website https://tender.nprocure.com/
Quantity
MSME Exemption No
Tender Type Open Tender
Startup Exemption Click Here
Competitive Bidding NCB
Similar Tenders
TENDER INSIGHTS

858

Electric Tenders
Live
CLICK TO KNOW MAXIMUM WIN

Tell us about your Product / Services,

We will Find Tenders for you

🇮🇳 +91
TenderDetail
Loading tenders