Tender Summary / Eligibility Criteria
Restoring Of Existing Damaged Retaining Wall And Balconies Under Special Repairs At GST Quarters, Mysuru.
Documents
Download All
No Boq
No Corrigendum
Probable Bidders
AI engine predicts probable bidders to help you bid strategically.
MSME Exception
Technical
Tender involves procurement of high capacity electrical equipment including diaphragm coupling of pump &
motor with 90kW capacity at 2900 RPM. The project scope includes installation, testing, commissioning and
operational handover.
Previous / Similar Result
BRR : 3370408
Tender For ARALAM SLEC , MANJALAMKAD WSS , PACHIKUND WSS,PATHINARAMPANTHAL WSS , ULIKKAL TOWN WSS AND ZAM ZAM THOTTIPALAMWSS SUSTAINABILITY SUPPORT PROJECT 2023-2024, ARALAM GP AND ULIKKAL GP,KANNUR DISTRICT-- 1 APPENDIX A: ARALAM SLEC IN ARALAM GP 2 KOTTAKKUNNU RESERVOIR 3 13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer 4 13.60.1 : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work 5 13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work 6 10.25.2 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 7 od57714/2024_2025 : Supply of uPVC Ppipe, IS 4985:2000,12.5 kg/cm2 , 110mm Dia 8 100.9.9 : Laying UPVC pipesof class 2 to class 6 andspecials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure(excluding cost of pipes and specials). 110 mm nominal outer dia pipes. 9 15.44.2 : Dismantling G.I. pipes ( external work) including excavation and refilling trenches after taking out the pipes, manually / by mechanical means including stacking ofpipes within 50 metres lead as per direction of Engineer- in- Charges:Above 40 mm nominalbore 10 13.7.1 : 12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand) 11 22.23.1 : Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @0.70 kg per sqm 12 13.71 : Lettering with black Japan pint of approved brand and manufacture 13 KODUVALLAM RESERVOIR 14 10.25.2 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 15 13.7.1 : 12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand) 16 13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 17 13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer 18 13.60.1 : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work 19 22.23.1 : Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @0.70 kg per sqm 20 13.71 : Lettering with black Japan pint of approved brand and manufacture 21 PANNIMOOLA RESERVOIR 22 10.25.2 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 23 Supply and fixing fiber door for Koduvallam tank 24 Water quality 25 APPENDIX B: MANJALAMKADU , ULIKKAL GP 26 PUMPING MAIN SYSTEM 27 100.98.234 : Supply of uPVC Pipe, IS 4985:2000 , 10kg/cm2, 63mm Dia. 28 100.1.1 : Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil (Ref. Item No. 2.10.1 of DSR) 29 100.9.6 : Laying UPVC pipesof class 2 to class 6 andspecials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure(excluding cost of pipes and specials). 63 mm nominal outer dia pipes. 30 18.12.6 : Providing and fixing G.I. pipes complete with G.I fittings including trenching and refilling etc. External work50 mm dia nominal bore 31 RESERVOIR 32 22.23.2 : Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm. 33 13.37.1 : White washing with lime to give an even shade:New work (three ormore coats) 34 13.60.1 : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work 35 PUMPHOUSE 36 13.37.1 : White washing with lime to give an even shade:New work (three ormore coats) 37 13.60.1 : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work 38 Distribution system 39 100.98.231 : Supply of uPVC Pipe, IS 4985:2000 , 10kg/cm2, 32mm Dia. 40 100.98.232 : Supply of uPVC Pipe, IS 4985:2000 , 10kg/cm2, 40mm Dia. 41 100.9.3 : Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials). 32 mm nominal outer dia pipes. 42 100.9.4 : Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials). 40 mm nominal outer dia pipes. 43 100.1.1 : Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil (Ref. Item No. 2.10.1 of DSR) 44 18.17.3 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore 45 18.17.4 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore 46 Well Repairing 47 100.54.3.2 : Desilting open wells of dia above 3.5m and up to 6.0m and depth up to 6.0m by earth work excavation in or under water, after closing the inlet valves and plugging any holes in the steining by engaging divers with breathing accessories, bailing out water using pumset of suitable capacity, lifting the excavated silt/mud/clay using ropes, pulleys and buckets and disposing the same within minimum lead of 50 m from the periphery of the well, including engaging coolies for scrapping the inner side of the well, without causing any damages to the existing structures and installations, including hire and conveyance of tools and plant and as per the directions of the department officers etc. complete. 48 15.3 : Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge. 49 100.7.1 : Bailing out water with5 HP engine and pumpset including conveyance to the site, errection, dismantling and taking back of engine and pump, cost of fuel lubricating oil and other stores pay of staff etc. complete. NEW DATA (Prepared based on PHED SDB - Item No.1070 50 50.10.1 : Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete 51 18.12.5 : Providing and fixing G.I. pipes complete with G.I fittings including trenching and refilling etc. External work40 mm dia nominal bore 52 13.71 : Lettering with black Japan pint of approved brand and manufacture 53 Water level indicator 54 Water quality 55 Supply and erecting openwell submersible pumpset with 3010 lph discharge against 47m headwith all accessories for panal board 56 Panal board replacing damaged items in existing board 57 APPENDIX C : PACHIKUND WSS , ULIKKAL GP 58 WELL CLEANING 59 2.32 : Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared. 60 100.54.3.1 : Desilting open wells of dia above 3.5m and up to 6.0m and depth up to 4.5m by earth work excavation in or under water, after closing the inlet valves and plugging any holes in the steining by engaging divers with breathing accessories, bailing out water using pumset of suitable capacity, lifting the excavated silt/mud/clay using ropes, pulleys and buckets and disposing the same within minimum lead of 50 m from the periphery of the well, including engaging coolies for scrapping the inner side of the well, without causing any damages to the existing structures and installations, including hire and conveyance of tools and plant and as per the directions of the department officers etc. complete. 61 13.88 : Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete 62 PUMP HOUSE AND TANK RENNOVATION 63 13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 64 13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer 65 13.60.1 : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work 66 22.24 : Providing and applying integral crystalline (dry shake) of hydrophilic in nature for waterproofing treatment to the RCC structures like basement raft, foundation slab, sewage & water treatment plant slab, warehouses floor, parking structures and water tank base slab etc. sprinkled @0.60kg per sqm or higher as recommended by the manufacturers specification over the lean concrete of above cited structures. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e. by reducing permeability of concrete by more than 85%, compared control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline dryshake shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the Engineer-incharge. The product performance shall carry guarantee for 10 years against any leakage. 67 PUMPING MAIN 68 100.98.152 : Supply of PE Pipe, PE100, PN10, 63mm dia, conforming to IS 4984/2016. 69 100.98.234 : Supply of uPVC Pipe , IS 4985:2000 , 10kg/cm2, 63mm Dia. Including specials 70 100.98.235 : Supply of uPVC Pipe, IS 4985:2000 , 10kg/cm2, 75mm Dia.including specials 71 100.9.6 : Laying UPVC pipesof class 2 to class 6 andspecials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure(excluding cost of pipes and specials). 63 mm nominal outer dia pipes. 72 100.1.1 : Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil (Ref. Item No. 2.10.1 of DSR) 73 DISTRIBUTION SYSTEM 74 100.1.1 : Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil (Ref. Item No. 2.10.1 of DSR) 75 100.98.230 : Supply of uPVC Pipe,IS 4985:2000 , 10kg/cm2, 25mm. Including specials 76 100.98.231 : Supply of uPVC Pipe, IS 4985:2000 , 10kg/cm2, 32mm Dia.Including specials 77 100.98.232 : Supply of uPVC Pipe, IS 4985:2000 , 10kg/cm2, 40mm Dia.Including specials 78 100.98.151 : Supply of PE Pipe, PE100, PN10, 50mm dia, conforming to IS 4984/2016. 79 100.98.152 : Supply of PE Pipe, PE100, PN10, 63mm dia, conforming to IS 4984/2016. 80 100.9.2 : Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials). 25 mm nominal outer dia pipes. 81 100.9.3 : Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials). 32 mm nominal outer dia pipes. 82 100.9.4 : Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials). 40 mm nominal outer dia pipes. 83 100.9.5 : Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials) 50 mm nominal outer dia pipes. 84 100.9.6 : Laying UPVC pipesof class 2 to class 6 andspecials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure(excluding cost of pipes and specials). 63 mm nominal outer dia pipes. 85 18.17.3 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore 86 18.17.4 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore 87 18.17.5 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :65 mm nominal bore 88 od58302/2024_2025 : Providing 15mm (1/2 inch) house connection with 15mm (1/2 inch) water meter from existing PVC branch lines, up to a length of 5 m using 20mm Indian Standard Class 6 uPVC pipe and uPVC / GM / Brass specials viz.Elbow, FTA, couplers, PVC Service saddle of suitable size etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe, fixing water meter, lighting, watching, providing caution boards,traffic control etc complete including cost of materials, hire for tools, cost of consumables and labour charges, including the cost of tested Class B Multijet water meter with ISI mark and weather resistant PP / PEmeter box of minimum size 300mm x 200mm x 150mm but excluding charges for cutting the concrete / tarred / bituminous roads etc and as per the direction of the departmental officers.<br> 89 100.60.12.3.1 : Providing 15mm PVC Tap in the water meter assembly for 15mm connection, using 20mm Indian Standard Class 6 uPVC pipes and specials including cost of materials, consumables, hire charges for tools and labour charges etc. complete and as per the direction of departmental officers. 90 100.98.211 : Supply of uPVC Pipe, IS 4985:2000 , 6kg/cm2, 63mm Dia.. 91 4.1.5 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 92 Supply and erecting openwell submersible pump set with 1.04 lps discharge against 100m headwith all accessories for panal board (Before installation actual site requirement verified) 93 water quality 94 APPENDIX D : PATHINARAMPANTHAL WSS , ULIKKAL GP 95 OPEN WELL OF DIA 4M AND DEPTH 6M 96 2.31 : Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared 97 100.3.5.1 : Earthwork open well excavation (above water) for wells of dia. above 3.5m and upto 6.0 m in all kinds of soil and conveying and depositing the spoil within initial lead of 50m and lift up to 1.5 m including neat banking. NEW DATA (Prepared based on PHED SDB - Item No.1089 & 1092 98 100.3.5.2 : Earthwork open well excavation (above water) for wells of dia. above 3.5m and upto 6.0 m in all kinds ofsoil and conveying and depositing the spoil within initial lead of 50m and lift from 1.5m to 3.0 m including neat banking. NEW DATA (Prepared based on PHED SDB - Item No.1089 & 1092 99 100.3.5.13 : Earthwork open well excavation (in or under water) for wells of dia. above 3.5m and upto 6.0 m in all kinds ofsoil and conveying and depositing the spoil within initial lead of 50m and lift from 3.0mto 4.5 m including neat banking. NEW DATA (Prepared based on PHED SDB - Item No.1090 & 1093 100 100.3.6.14 : Earthwork open well excavation (in or under water) for wells of dia. above 3.5m and upto 6.0 m in ordinary rock in ordinary rockand conveying and depositing the spoil within initial lead of 50m and lift from 4.5mto 6.0 m including neat banking. NEW DATA (Prepared based on PHED SDB - Item No.1096 101 5.4 : Providing and laying up to floor five level reinforced cement concrete in kerbs, steps and the like excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (Zone - III) : 3 graded stone aggregate 20 mm nominal size) 102 50.6.7.1 : Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for foundation and basement including all cost of materials, labour charges etc. 103 5.1.3 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 104 5.3 : Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size). 105 5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete 106 5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform 107 5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers 108 5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more 109 100.7.1 : Bailing out water with5 HP engine and pumpset including conveyance to the site, errection, dismantling and taking back of engine and pump, cost of fuel lubricating oil and other stores pay of staff etc. complete. NEW DATA (Prepared based on PHED SDB - Item No.1070 110 13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 111 13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer 112 13.60.1 : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work 113 PUMP HOUSE OVER THE WELL 114 50.6.1.5 : Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete 115 13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 116 13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer 117 13.60.1 : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work 118 12.1.2 : Providing corrugate G.S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete ( up to any pitch in horizontal / vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.0.80 mm thick with zinc coating less than 275 gm/m2 119 50.10.1 : Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete 120 13.71 : Lettering with black Japan pint of approved brand and manufacture 121 100.98.209 : Supply of uPVC Pipe, IS 4985:2000 , 6kg/cm2, 40mm Dia. 122 PUMPING MAIN 123 100.98.152 : Supply of PE Pipe, PE100, PN10, 63mm dia, conforming to IS 4984/2016. 124 100.1.1 : Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil (Ref. Item No. 2.10.1 of DSR) 125 100.9.6 : Laying UPVC pipesof class 2 to class 6 andspecials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure(excluding cost of pipes and specials). 63 mm nominal outer dia pipes. 126 18.12.6 : Providing and fixing G.I. pipes complete with G.I fittings including trenching and refilling etc. External work50 mm dia nominal bore 127 100.98.234 : Supply of uPVC Pipe, IS 4985:2000 , 10kg/cm2, 63mm Dia. 128 18.17.4 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore 129 CONSTRUCTION OF A OHSR 7500 LTR CAPACITY 130 2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil 131 4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 132 5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size 133 5.3 : Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size). 134 5.2.2 : Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) 135 5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete 136 5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform 137 5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers 138 5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts 139 5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more 140 13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 141 13.7.1 : 12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand) 142 13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer 143 13.60.1 : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work 144 10.25.2 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 145 13.71 : Lettering with black Japan pint of approved brand and manufacture 146 100.98.233 : Supply of uPVC Pipe, IS 4985:2000 , 10kg/cm2, 50mm Dia. 147 100.98.235 : Supply of uPVC Pipe, IS 4985:2000 , 10kg/cm2, 75mm Dia. 148 WATER QUALITY TEST 149 HYDROGEOLOGICAL SURVEY 150 Supplying and fixing MS Door and concrete frame for door and ventilator frame 151 Supply and erecting openwell submersible pumpset with 1.39 lps discharge against 80m hradwith all accessories for panal board (Actual head must be check before installation) 152 Water level indicator 153 APPENDIX E : ULIKKAL TOWN WSS , ULIKKALGP 154 Well deepening 155 100.3.4.14 : Earthwork open well excavation (in or under water) for wells of dia. above 2.5m and upto 3.50 m in ordinary rock in ordinary rockand conveying and depositing the spoil within initial lead of 50m and lift from 4.5m to 6.0 m including neat banking. NEW DATA (Prepared based on PHED SDB - Item No.1087 156 100.3.4.15 : Earthwork open well excavation (in or under water) for wells of dia. above 2.5m and upto 3.50 m in ordinary rock in ordinary rockand conveying and depositing the spoil within initial lead of 50m and lift from 6.0m to 7.5 m including neat banking. NEW DATA (Prepared based on PHED SDB - Item No.1087 157 100.7.1 : Bailing out water with5 HP engine and pumpset including conveyance to the site, errection, dismantling and taking back of engine and pump, cost of fuel lubricating oil and other stores pay of staff etc. complete. NEW DATA (Prepared based on PHED SDB - Item No.1070 158 50.6.7.1 : Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for foundation and basement including all cost of materials, labour charges etc. 159 5.1.3 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 160 5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers 161 5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more 162 12.1.2 : Providing corrugate G.S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete ( up to any pitch in horizontal / vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.0.80 mm thick with zinc coating less than 275 gm/m2 163 13.71 : Lettering with black Japan pint of approved brand and manufacture 164 PUMPING MAIN AND DISTRIBUTION 165 100.98.173 : Supply of PE Pipe, PE100, PN12.5, 75mm dia, conforming to IS 4984/2016. 166 100.98.152 : Supply of PE Pipe, PE100, PN10, 63mm dia, conforming to IS 4984/2016. 167 100.98.153 : Supply of PE Pipe, PE100, PN10, 75mm dia, conforming to IS 4984/2016. 168 100.98.230 : Supply of uPVC Pipe,IS 4985:2000 , 10kg/cm2, 25mm. Including specials 169 100.98.151 : Supply of PE Pipe, PE100, PN10, 50mm dia, conforming to IS 4984/2016. 170 100.98.231 : Supply of uPVC Pipe, IS 4985:2000 , 10kg/cm2, 32mm Dia. Including specials 171 100.9.2 : Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials). 25 mm nominal outer dia pipes. 172 100.9.3 : Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials). 32 mm nominal outer dia pipes. 173 100.9.5 : Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials) 50 mm nominal outer dia pipes. 174 100.9.6 : Laying UPVC pipesof class 2 to class 6 andspecials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure(excluding cost of pipes and specials). 63 mm nominal outer dia pipes. 175 100.9.7 : Laying UPVC pipesof class 2 to class 6 andspecials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure(excluding cost of pipes and specials). 75 mm nominal outer dia pipes. 176 100.1.1 : Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil (Ref. Item No. 2.10.1 of DSR) 177 od56632/2024_2025 : Providing 15mm (1/2 inch) house connection with 15mm (1/2 inch) water meter specials, Elbow, MTA, FTA, couplers and connecting pipe with the connecting pipe and service pipe ,fixing watermeter ,lighting watchingproviding caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges, including the cost of tested Class B Multijet water meter with ISI mark and weather resistant PP / PE meter box of minimum size 300mm x 200mm x 150mm, but excluding charges for cutting the concrete / tarred / bituminous roads etc, and as per the direction of the departmental officers. 178 100.60.12.3.1 : Providing 15mm PVC Tap in the water meter assembly for 15mm connection, using 20mm Indian Standard Class 6 uPVC pipes and specials including cost of materials, consumables, hire charges for tools and labour charges etc. complete and as per the direction of departmental officers. 179 od56633/2024_2025 : Providing 15mm (1/2 inch) house connection with 15mm (1/2 inch) water meter from existing PVC / HDPE mains up to 110 mm dia., up to a length of 5 m using 20mm Indian Standard Class 6 uPVC pipe and uPVC / GM / Brass specials viz.Elbow, MTA, FTA, couplers, PVC Service Saddle of suitable size etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe, fixing water meter, lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges, including the cost of tested Class B Multijet water meter with ISI mark and weather resistant PP / PE meter box of minimum size 300mm x 200mm x 150mm, but excluding charges for cutting the concrete / tarred / bituminous roads etc, and as per the direction of the departmental officers.<br> 180 4.1.5 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 181 Repairing works in Reservoir 182 22.24 : Providing and applying integral crystalline (dry shake) of hydrophilic in nature for waterproofing treatment to the RCC structures like basement raft, foundation slab, sewage & water treatment plant slab, warehouses floor, parking structures and water tank base slab etc. sprinkled @0.60kg per sqm or higher as recommended by the manufacturers specification over the lean concrete of above cited structures. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e. by reducing permeability of concrete by more than 85%, compared control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline dryshake shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the Engineer-incharge. The product performance shall carry guarantee for 10 years against any leakage. 183 od56630/2024_2025 : Supply and fixing weld mesh 50 mm x 50mm , 12 gauge.<br> 184 od56631/2024_2025 : Supply and fixing chicken mesh 12x 24 gauge<br> 185 13.7.1 : 12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand) 186 13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer 187 13.60.1 : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work 188 Water Quality 189 Supply and erecting open well submersible pumpset with 1.85 lps discharge against 80meter headwith all accessories for panal board ( actual head must be check before installation) 190 Water level indicator 191 Providing and fixing fibre door with frame for pump house 192 APPENDIX F : ZAM ZAM THOTTILPALAM WSS , ULIKKAL GP 193 DISTRIBUTION SYSTEM 194 100.98.230 : Supply of uPVC Pipe,IS 4985:2000 , 10kg/cm2, 25mm. 195 100.98.231 : Supply of uPVC Pipe, IS 4985:2000 , 10kg/cm2, 32mm Dia. 196 100.98.232 : Supply of uPVC Pipe, IS 4985:2000 , 10kg/cm2, 40mm Dia. 197 100.98.233 : Supply of uPVC Pipe, IS 4985:2000 , 10kg/cm2, 50mm Dia. 198 100.98.132 : Supply of PE Pipe, PE100, PN8, 63mm dia, conforming to IS 4984/2016. 199 100.9.2 : Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials). 25 mm nominal outer dia pipes. 200 100.9.3 : Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials). 32 mm nominal outer dia pipes. 201 100.9.4 : Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials). 40 mm nominal outer dia pipes. 202 100.9.5 : Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials) 50 mm nominal outer dia pipes. 203 100.9.6 : Laying UPVC pipesof class 2 to class 6 andspecials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure(excluding cost of pipes and specials). 63 mm nominal outer dia pipes. 204 100.1.1 : Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil (Ref. Item No. 2.10.1 of DSR) 205 od193733/2023_2024 : Providing 15mm (1/2 inch) house connection with 15mm (1/2 inch) water meter from existing PVC branch lines, up to a length of 5 m using 20mm Indian Standard Class 6 uPVC pipe and uPVC / GM / Brass specials viz.Elbow, FTA, couplers, PVC Service saddle of suitable size etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe, fixing water meter, lighting, watching, providing caution boards,traffic control etc complete including cost of materials, hire for tools, cost of consumables and labour charges, including the cost of tested Class B Multijet water meter with ISI mark and weather resistant PP / PEmeter box of minimum size 300mm x 200mm x 150mm but excluding charges for cutting the concrete / tarred / bituminous roads etc and as per the direction of the departmental officers.<br> 206 100.60.12.3.1 : Providing 15mm PVC Tap in the water meter assembly for 15mm connection, using 20mm Indian Standard Class 6 uPVC pipes and specials including cost of materials, consumables, hire charges for tools and labour charges etc. complete and as per the direction of departmental officers. 207 100.98.211 : Supply of uPVC Pipe, IS 4985:2000 , 6kg/cm2, 63mm Dia.. 208 4.1.3 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 209 18.17.2 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore 210 18.17.4 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore 211 RESERVOIR AND PUMP HOUSE RENNOVATION 212 13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 213 13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer 214 13.60.1 : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work 215 13.71 : Lettering with black Japan pint of approved brand and manufacture 216 10.25.2 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 217 Water quality
BRR : 10693427
Tender For Special Repair Internal And External Painting Of Cgm Qrtr At Main T.E Campus Ranchi; 1 Sh: Concrete Work 2 Providing And Laying Cement Concrete In Retaining Walls, Return Walls, Walls ( Any Thickness ) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets, Sunken Floor Etc., Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering And Finishing: 3 1:1½:3 ( 1 Cement : 1½ Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources 4 Sh: Rcc Work 5 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: 6 Small Lintels Not Exceeding 1.5 M Clear Span, Moulding As In Cornices, Window Sills, String Courses, Bands, Copings, Bed Plates, Anchor Blocks And The Like 7 Sh: Masonry Work 8 Brick Work With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 5.0 In Superstructure Above Plinth Level Up To Floor V Level In All Shapes And Sizes In : 9 Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) 10 Sh: Wood Work 11 Providing And Fixing Aluminium Hanging Floor Door Stopper, Isi Marked, Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour And Shade, With Necessary Screws Etc. Complete. 12 Twin Rubber Stopper 13 Sh: Steel Work 14 Steel Work Welded In Built Up Sections / Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required. 15 In Stringers, Treads, Landings Etc. Of Stair Cases, Including Use Of Chequered Plate Wherever Required, All Complete. 16 Sh: Roofing 17 Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion, ( I ) Single Socketed Pipes. 18 110 Mm Diameter 19 Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A Including Jointing With Seal Ring Conforming To Is :5382 Leaving 10 Mm Gap For Thermal Expansion. 20 Bend 87.5° 21 110 Mm Bend 22 Shoe ( Plain ) 23 110 Mm Bend 24 Providing And Fixing Unplasticised -Pvc Pipe Clips Of Approved Design To Unplasticised - Pvc Rain Water Pipes By Means Of 50X50x50mm Hardwood Plugs, Screwed With M.S. Screws Of Required Length Including Cutting Brick Work And Fixing In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) And Making Good The Wall Etc. Complete. 25 110 Mm 26 Sh: Finishing 27 12 Mm Cement Plaster Finished With A Floating Coat Of Neat Cement Of Mix: 28 1:4 ( 1 Cement: 4 Fine Sand ) 29 Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface : 30 Water Thinnable Cement Primer. 31 Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade : 32 New Work ( Two Or More Coat Applied @ 1.67 Ltr / 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg / 10 Sqm ) 33 Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade: 34 Two Or More Coats On New Work. 35 Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. 36 Wall Painting With Acrylic Emulsion Paint, Having Voc ( Volatile Organic Compound ) Content Less Than 50 Grams / Litre, Of Approved Brand And Manufacture, Including Applying Additional Coats Wherever Required, To Achieve Even Shade And Colour. 37 Two Coats 38 Painting ( One Or More Coats ) On Rain Water, Soil Waste And Vent Pipes And Fittings With Black Anticorrosive Bitumastic Paint Of Approved Brand And Manufacture On Old Work: 39 100 Mm Diameter Pipes . 40 Distempering With 1St Quality Acrylic Distember ( Ready Mix ) Having Voc Content Less Than 50 Grams / Litre Of Approved Brand And Manufacture To Give An Even Shade : 41 Old Work ( One Or More Coats ) . 42 Removing Dry Or Oil Bound Distemper, Water Proofing Cement Paint And The Like By Scrapping, Sand Papering And Preparing The Surface 43 Wall Painting With Plastic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade : 44 One Or More Coats On Old Work. 45 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade: 46 One Or More Coats On Old Work 47 French Spirit Polishing : 48 One Or More Coats On Old Work. 49 Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade: 50 Old Work ( Two Or More Coat Applied @ 1.67 Ltr / 10 Sqm ) On Existing Cement Paint Surface 51 Sh: Repairs To Building 52 Repairs To Plaster Of Thickness 12 Mm To 20 Mm In Patches Of Area 2.5 Sq.Meters And Under, Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete, Including Disposal Of Rubbish To The Dumping Ground Within 50 Metres Lead : 53 With Cement Mortar 1:4 ( 1Cement: 4 Coarse Sand ) . 54 Renewing Glass Panes, With Wooden Fillets Wherever Necessary: 55 Float Glass Panes Of Nominal Thickness 4 Mm ( Weight Not Less Than 10Kg / Sqm ) 56 Providing And Fixing App ( Atactic Polypropylene Polymer ) Modified Prefabricated Five Layer 2 Mm Thick Water Proofing Membrane, Black Finished Reinforced With Glass Fibre Matt Consisting Of A Coat Of Bitumen Primer For Bitumen Membrane @ 0.40 Litre / Sqm By The Same Membrance Manufacture Of Density At 25°C, 0.87 - 0.89 Kg / Litre And Viscocity 70 - 160 Cps. Over The Primer Coat The Layer Of Membrane Shall Be Laid Using Butane Torch And Sealing All Joints Etc., And Preparing The Surface Complete. The Vital Physical And Chemical Parameters Of The Membrane Shall Be As Under : Joint Strength In Longitudinal And Transverse Direction At 23°C As 350 / 300 N / 5 Cm. Tear Strength In Longitudinal And Transverse Direction As 60 / 80N. Softening Point Of Membrane Not Less Than 150°C. Cold Flexibility Shall Be Upto -2°C When Tested In Accordance With Astm, D - 5147. The Laying Of Membrane Shall Be Got Done Through The Authorised Applicator Of The Manufacture Of Membrane. 57 2Mm ( For Corrugated Roof Sheets ) 58 Providing & Fixing Single Scaffolding System On The Exterior Side Of Building Made With 50 Mm Dia ( Approx ) Bamboo Tree 1.00 Metre Centre To Centre Horizontal & Vertical For Repair Of Projected Roof Maintaining It In A Serviceable Condition For The Required Duration As Approved And Removing It There After Complete As Per Direction Of Engineer-In-Charge. 59 Sh: Dismantling & Demolishing 60 Demolishing Cement Concrete Manually / By Mechanical Means Including Disposal Of Material Within 50 Metres Lead As Per Direction Of Engineer - In - Charge. 61 Nominal Concrete 1:3:6 Or Richer Mix ( I / C Equivalent Design Mix ) 62 Disposal Of Building Rubbish / Malba / Similar Unserviceable, Dismantled Or Waste Materials By Mechanical Means Including Loading, Transporting, Unloading To Approved Municipal Dumping Ground Or As Approved By Engineer-In-Charge, Beyond 50 M Initial Lead, For All Loads Including All Lifts Involved. 63 Sh: Water Proofing 64 Painting Two Or More Coats With Dr. Fixit 653, Roof Seal Select Water Proofing Paint After Cleaning Of Roof Surface Of Required Colour To Give An Even Shade And Filling Holes And Cracks With Crack Fill Of Sika Make As Per Direction And Satisfaction Of Engineer-In-Charge. ( Note: Before Painting, Roof Surface Should Be Cleaned And Dry. Crack Fill Of Sika Make Will Be Separately ) . 65 Supply Of Sika Make Crack Fill As Per Direction And Satisfaction Of Engineer-In-Charge. 66 Grading Roof For Water Proofing Treatment With 67 Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ) 68 Cement Mortar 1:4 ( 1Cement : 4 Coarse Sand ) 69 Sh: Repairs & Rehabilitation 70 Chipping Of Unsound / Weak Concrete Material From Slabs, Beams, Columns Etc. With Manual Chisel And / Or By Standard Power Driven Percussion Type Or Of Approved Make Including Tapering Of All Edges, Making Square Shoulders Of Cavities Including Cleaning The Exposed Concrete Surface And Reinforcement With Wire Brushes Etc. And Disposal Of Debris For All Lead And Lifts All Complete As Per Direction Of Engineer-In-Charge. 71 50 Mm Average Thickness 72 Cleaning Of Reinforcement From Rust From The Reinforcing Bars To Give It A Total Rust Free Steel Surface By Using Alkaline Chemical Rust Remover Of Approved Make With Paint Brush And Removing Loose Particles After 24 Hours Of Its Application With Wire Brush And Thoroughly Washing With Water And Allowing It To Dry, All Complete As Per Direction Of Engineer-In-Charge 73 Bars Upto 12 Mm Diameter 74 Bars Above 12 Mm Diameter 75 Providing, Mixing And Applying Bonding Coat Of Approved Adhesive On Chipped Portion Of Rcc As Per Specifications And Direction Of Engineer-In-Charge Complete In All Respect. 76 Epoxy Bonding Adhesive Having Coverage 2.20 Sqm / Kg Of Approved Make 77 Replacement Of Sufficiently Damaged Reinforcements Or Providing Additional Reinforcements With The Damaged Reinforcements By Welding Etc. Includingcost Of Reinforcement ( Tmtbar Of Required Dia ) , Mobilization Etc. Complete As Per Direction Of Engineer-In-Charge. ( Work Is To Be Executed Upto 20 M Heights Above G.L ) . 78 Repairs Of Damaged Rcc Portion In Beams, Columns Floors, Roofs Having Slope Upto 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 ( 1 Cement : 1.5 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) . 79 50 Mm Average Thicknes 80 Plastering In Cement Mortar 1:3 ( 1 Cement:3 Fine Sand ) Of 6 Mm Thick Admixed With Water Proofing Compound Of Approved Make Such As Plastocrete Super Or Equivalent Confirming To Is 9103-1999, Is 2645-1975 And Astm C-494-86 Type A @ 0.2% By Weight Of Cement And As Per Manufacturer Specification Complete To Improve Water Tightness And Workabilitywithout Increased Water Contentand As Per Direction Of Engineer In Charge. ( Work Is To Be Executed Upto 20 M Heights Above G.L ) . 81 Extra For Providing & Fixing Liquid Intgral Water Proofing Materials Conforming To Is: 2645 Of The Approved Brand Such As Roff Hyproof / Laticrete Or Equivalent At The Rate Of 140Ml / 50Kg Bag Of Cement Or In Proportion As Recommended By The Manufacturer In Rcc / Cc / Cement Mortar Etc. As Per Direction Of Engineer-In-Charge. ( Note: Integral Liquid Water Proofing Material Shall Be Added In The Water Needed For Preparation Of Rcc / Cc / Mortar Etc. ) 82 Providing And Fixing Fly Proof Stainless Steel Grade 304 Wire Gauge With Removing / Refixingexisting Wooden Beading / 12Mm M.S U-Beading To Windows And Clerestory Windows Using Wire Gauge With Average Width Of Aperture 1.4Mm In Both Directions With Wire Of Dia. 0.50 Mm With Required Size Of S S Nains All Complete.
BRR : 8090817
CERTAIN MISC PETTY REPAIRS OF DAY TO DAY COMPLAINTS TO VARIOUS ACCNS, REPAIR/ MAINT TO DAMAGED ROOF/ CHAJJA, LEAKAGE SEEPAGE TREATMENT, PLUMBING, ATTENDING DAY TO DAY COMPLAINTS OF INTERNAL SUPPLY IN MD & OTM ACCN AT AFTC, CQAE (WE) & AFS JALAHALLI; 1 Use and waste of form work fair finished surfaces to sides and soffits of floor or roof beams, lintels, cantilevers etc all as specified and directed. 2 M&L for Steel reinforcement TMT bars 10mm dia and over cut to length and bent to shape required including cranking, bending spirally for hoping for columns, hooking end and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips incl removal of old reinforcement all as specified and directed. 3 M&L for Steel reinforcement TMT bars 6mm dia to 8mm dia cut to length and bent to shape required including cranking, bending spirally for hoping for columns, hooking end and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips incl removal of old reinforcement all as specified and directed. 4 M&L for Reinforced Cement Concrete (Nominal Mix) 1:1½:3 Type A1 (using 20 mm gradedstone aggregate) as in Slab/beam/columns supported on walls, beams and column in floors, balconies etc complete including demolition of old reinforced cement concrete and finishing the surface with one coat of white wash all as specified and directed. 5 Repair to cracks and damaged existing surface of RCC roof slab/RCC facia/RCC chajja upto double storey (Approx height 7.50 Mtr from the natural ground level) by structural strengthing using injection pressure grouting with Sikadur 52, low viscous epoxygroutof Make M/s Sika India Pvt Ltd, or equivalent in M/s Fosroc Chemicals, M/s Thermex Limited, M/s STP Limited, (as approved by GE), complete all as manufacturers and all as specified and directed by GE as under:- 6 Providing and drilling 10mm dia holes using pneumatic drill as per site condition but not exceeding 50cm c/c in zig-zag patten for 75mm depth and fixing high pressure bear up Metal/Aluminium body indection packer along the holes and packing with Sika rep Micro Crete 4, rapid setting cement based plugging mortar of Make M/s Sika India Pvt Ltd, or equivalent in M/s Fosroc Chemicals, M/s Thermex limited,M/s STP Limited, (as approved by GE) 7 Mixing base and hardner of Sikadur 52, low viscous solvent free epoxy injection grout of Make M/s Sika India Pvt Ltd, or equivalent in M/s Fosroc Chemicals,M/s Thermex limited,M/s STP Limited, (as approved by GE)using slow speed electricity operated mixing paddle (200-300RPM) and injecting the same using electrically operated high pressure (upto 1000 Kgf/SqCM) pump until refusal to adjacent complete as per manufacturers specification. 8 Cutting and flushing the nozzoles and excess materials with a sharp scraper to take away sharp protrusions and to get a smooth and flat finish 9 Note :- The work under (item No. 5 to item No. 8 of BOQ) shall be carried out through authorized and qualified applicators of the any following manufacturer only. M/s Sika India Pvt Ltd, M/s Fosroc Chemicals, M/s STP Limited, M/s Thermax Limited 10 A performance guarantee certificate for two years shall be submitted by the contractor to the GE on completion of work as specified 11 The unit rate quoted is deemed to included for Removing of accumulated earth of any width and depth upto 15 cm cleaning/cutting the grass with hand operated petrol/kerosene driven grass cutting machine and removing the grass waste around 3 m from plinth protectionto outside MD land Note: Periodicityof cutting of grass shall be before commencement of work and after completion of repairs. 12 M&L for Dismantling/ taking down old existing unserviceable cement plaster, loose/ unsound weaken cement concrete of any description and in any position from existing external / internal surface of RCC roof/ slab/ beams/ columns/ RCC facia for an average depth of 25mm (Approx height 7.5m from natural ground level) with power driven pneumatic flat/pointed chisel and removing the honeycombed area including all the corners and making a neat profile of the cavities, roughen the smooth surface , scrapping out/removing corrosion all loose/scale/rust etc form the visible reinforcement by applying rust remover such as Rust Off 100 of make M/s Sika India Pvt Ltd, or equivalent in M/s Fosroc Chemicals, M/s STP Limited, M/s ThermaxLimited( as approved by GE) and cleaning the steel reinforcement properly, complete all as per manufactures instructionand all as specified and directed by Engineer-in-Charge. 13 Note for item No. 12 :-(a) Providing cement based angle fillet for 75mm X 75mm admixer with Sikacim, integralwaterproofing liquid M/s Sika India Pvt Ltd, or equivalent in M/s Fosroc Chemicals, M/s Choksey Chemicals Pvt., M/s BOSTIk India pvt limited, M/s STP Limited, (as approved by GE) @ 0.2% by weight of cement or as per manufacturer’sinstructions over a coat of acrylic emulsion bonding agent, such as Sika Latex in 1:1:3 ratio of Make M/s Sika India Pvt Ltd, or equivalent in M/S Fosrox chemicals, M/s STP Limited, M/s Thermex Ltd (as approved by GE) having specific gravity of 1.02 or as per manufacturer’s instructions with necessary surface preparation such as creating mechanical key like rougheing the surface by scrabbing, grit blasting and cleaning the existing surface using high pressure water jet machine having pressure upto 500 barpressure to remove the dirt, dust, loose particles , wax, efforencene and other contaminations from the surface of RCC columns/ beams/ slabs/ facia/ any brick/ stone surfaces etc complete all as manufactures instructions and all as specified and directed by Engineer-in-Charge. 14 (b) Providing and applying FRIAZINC R, corrosion inhabiliting Active Zinc rich primer of make M/s Sika India Pvt Ltd, or equivalent in M/s Fosroc Chemicals, M/s STP Limited, M/s Thermex Ltd (as approved by GE) along the exposed reinforcement surface property and allowed to dry. 15 (c)Providing and applying Hibond, Epoxy based Thixotropic bonding adhesive of Make from M/s Sika India Pvt Ltd, or equivalent in M/s Fosroc Chemicals, M/s Choksey Chemicals Pvt., M/s BOSTIk India pvt limited, M/s STP Limited, ( as approved by GE) over the prepared concrete surface to get a good bonding between existing concrete surface and providing Sika Rep Microcrete 4 Fiber reinforced cementitious repair micro concrete of make M/s Sika India Pvt Ltd, or equivalent in M/s Fosroc Chemicals, M/s STP Limited, M/s Thermex Ltd ( as approved by GE) over Epoxy based bonding agent applied area before 6 Hrs etc including providing necessary proportions , bracing and runners to relieve the member from the load coming on it including scaffolding leak proof shuttering with working platform as required and as per design and pattern complete including preparing the surface to match with the existing surface,complete all as specified and directed. 16 (d) Note : The work under (Item No. 12 to Item No. 15 of BOQ) shall be carried out through authorized and qualified applicators from any of the following manufacturer only. M/s Sika India Pvt Ltd, M/s Fosroc Chemicals, M/s STP Limited, M/s ThermaxLimited 17 (i)A performance guarantee certificate for two years shall be submitted by the contractor to the GE on completion of work as specified. 18 (ii) The unit rate quoted for item No. 12 to 15 of BOQ is deemed to be included for Removing of accumulated earth of any width and depth upto 15 cm cleaning/cutting the grass with hand operated petrol/kerosene driven grass cutting machine and removing the grass waste around 3 m from plinth protectionto outside MD land Note: Periodicityof cutting of grass shall be before commencement of work and after completion of repairs. 19 Taking down chowkhat or frame (wooden/steel) exceeding 1.50 Sqm not exceeding4.0 Sqm each with shutter (with out taking off shutters from the frame) all as specified and as directed. 20 Taking down shutters of any description exc 1.0 Sq.m andn.exc 2.0 Sq.m each complete all as specified and directed. 21 M&L Second class hard wood plain, solid, straight Chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue pinned at jointscomplete all as specified and directed. 22 S&F 2nd class hard wood 35mm thick Factory made plain framed panelled shutter any number of panelswith lock rail and panel of 9mm BWP commercial ply or 12mm veneered partical board with commercial veneering on both faces. The size of rail and stile as per IS 1003 (Part-I), kiln seasoned and chemically pressure treated complete all as specified and directed. 23 S&F Factory made 35mm thick Glazed and skeleton shutters/windows, open rebated and prepared to receive glass, gauze, etc. divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers, edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a);all as specified and directed. 24 Preparation of new wood orwoodensurface of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed 25 Supply and fixing 100mm long Butt hinges medium weight cold rolledstainless steel, and fixed complete all as specified and as directed. 26 Supply and fixing 200 mm long aluminium anodized barrel tower bolt extruded section complete all as specified and as directed. 27 S&F aluminium handles cast type anodised 200 mm long complete all as specified and as directed. 28 S&F 250mm aluminium alloy, anodised, sliding door bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extrudud sections or cast aluminium alloy and fixed complete all as specified and as directed. 29 S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.4mm complete all as specified and directed. 30 Petty repair to wooden door,skelton door,flush door, wooden window, wooden ventilator, cupboard door, wardrobe door,PVC door with shutter (size upto 3 Sqm) including roller, windows, etc with minor repair and easying and adjustment/alignmentto openable with assessories and including taking down and refixing complete all as specified and directed. 31 Petty repair to aluminium section/glass doors, windows, ventilators, partitions and making good the same size upto 5 Sqm(i.e. including change of Handles, hinges, star lock, rubber beadings, bottom bearing, clips etc) including taking down and refixing complete all as specified and directed. 32 Supply and fixing in repairs 200 mm long aluminium anodized barrel tower bolt extruded section complete all as specified and as directed. 33 Supply and fixing 100mm long Butt hinges medium weight cold rolledstainless steel, fixed in repair to wooden frame/welded to metal frame complete all as specified and as directed. 34 S&F in repairs floor door stopper of aluminium alloy body and tongue anodized with hard drawn steel spring fixed in floor overall 140mm complete including taking down existing oneall as specified and as directed. 35 Supply and fixing in repairs aluminium handles cast type anodised 200 mm long complete all as specified and as directed. 36 Supply and Fixing in repairs 250mm Aluminium alloy, anodised, sliding door bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extrudud sections or cast- aluminium alloy and fixed complete all as specified and as directed. 37 S&F Aluminium body door closer hydraulically regulated,designation No.3, universal type, suitable for door shutters of 851 to1000 mm in width and of weight between 61 to 80 kg and fixed including taking down existing one complete all as directed. 38 S&F in repair powder coated aluminium curtain rod fancy type (colour as approved) of 20mm boreincludingbrackets, stops, rollers, etc. andfixed to wall with steel screws complete all as specified and as directed . 39 Taking down and refixing MS window shutters n. exe 1.5 sqm through cutting of existing any type of hinges, handle and tower bolt and fixing new box type hinges, MS handle and MS tower bolt the same window by necessary welding.The quoted rates shall be included the following aspect:-(a) Cutting of existing piano hinges, handle and tower bolt from window frame and shutter.(b) Fixing of removed shutter in the same frame on MS box type hinges 100mm, MS handle 100mm and MS tower bolt 100mm by welding.(c) Easing and adjusting the shutter before re-fixing if required.(d) Finishing the window frame and shutter with two coat of synthetic enamel paint.(e) Necessary scaffolding material to be included as the building height is more than 10mtr.Note :Box type hinges, handle and tower bolt shall be measured separately as supply only and labour element is deemed to be included in this item. 40 Supply only MS Box type hinges 50mm. 41 Supply only MS Handle 100mm. 42 Supply only MS tower bolt 75mm 43 Supply and fixing in repair steel window peg stay all as specified and directed. 44 S&F in repair looking mirror of size 600mm x 450mm on commerical ply wood 6mm thick with PVC/ wooden moulding beading fixed to wooden plugs with chromium plated brass, screws and cup, washers, aluminium frame and fixed complete all as specified and directed. 45 M&L for Preparation of old decoratedplastered or unplastered surfaceof wall, brooming down or steel wire brushing down smoke soot, moulds mass, efflorescent , trading, oil, greasy spots and applying one coat ofoil bound distemper complete all as specified and as directed. 46 Material and labourfor Preparation of old decoratedplastered or unplastered surfaceof wall, chajja,ceiling, balcony, facia etc., brooming down or steel wire brushing down smoke soot, moulds mass, efflorescent, trading, oil, greasy spots and applyingone coat of whitewashcomplete all as specified and directed. 47 M&L for Preparation of old painted wooden surface of any description and applying one coat of synthetic enamel paint, not otherwise described over 10 cm width or girth, complete all as specified and directed. 48 M&L for Preparation of old painted surfaces of steel and applying one coat of synthetic enamel paintover 10 cm width or girth, not other wise describedcomplete all as specified and as directed. 49 Treating the sunken floor slab comporising of the following specifications all as specified & directed:- 50 (a) Demolition of cement concrete of any description in sunken portion of toilet and removing debris outside MD land. 51 (b) Cleaning the sunken/ lowered portion of RCC slab surfaces (including vertical total depth plus skirting height) of floors by wire brush, chisel out any mortar sticking to the surface and brooming completely and providing 40mm thick (avg) PCC 1:2:4 type B-1 using 20mm graded aggregate as in padding concrete to achieve proper slope including cutting holes in bricks or RCC wall for provision ofspout (WPC measured and paid separately) 52 (c) Rendering of uneven surfaces with 10mm thick CM 1:4 mixed with required water proofing compound as per manufacturer instruction. Fill it with water and check dampness and seepage. Where dampness/ seepage is noticed, nozzles shall be fixed and grouting carried out. (WPC shall be measured and paid separately). 53 (d)All junctions points of side wall spout where CI/ GI pipes are passing through shall be sealed with epoxy putty. 54 (e)After drying putty, wash the slab and sides of sunken portion with water and make it clear and clean. 55 (f) Applying two coats of polymer modified cementious water proof coating as per manufacture instruction to bottom and vertical sides up to finished floor level+100mm height. The thickness of two layer shall be 1mm. When the second layer is still sticky, coarse sand spray shall be carried for the vertical and bottom surface of the sunken portion all as specified and directed. 56 (g)Plaster the bottom and sides up to bottom of the skirting with minimum 20mm thick CM 1:4 mixed with integral water proofing compound as per manufacturers specification including rounding of corners and junctions sloping towards spout. (WPC shall be measured & paid separately). 57 (h)Material and labourfor PCC 1:5:10 type E2, using 40mm thick aggregate n exc 150mmthick as in filling of sunken floor portion complete all as specified & directed. 58 (j) Material and labourfor PCC 1:2:4 type B1 using 20mm graded aggregate, 50mm tnick as in floor etc complete all as specified & directed. 59 Note :- (a)Testing of water proof area (ponding test) shall be done by filling water for at least 72 hours and tested for leakage, seepage to the entire satisfaction of GE. 60 (b) Test shall be done in presence of Engineer-in-Charge. 61 (c)The treatment shall be carried out by authorised applicator of chemicals. 62 (d)Cost of testing is included in the unit quoted rate above. 63 Material and labourfor Water proofing treatment to the sunken portion applying two coat of two component (1 part Polymer and second part cementations powder) cementations, polymer modified elastomeric, water proofing coating composed of cement, properly selected and graded aggregates, additive and acrylic emulsion polymer as a binder apply first coat of (mix and application as per manufacturer’s instructions) all over floor surface. Prepared surface and apply to vertical surface up to 15cm from tiling level, allow to dry 4 to 6 hours. Prepare for apply 2nd coat perpendicular to first coat and allow to dry 4 to 6 hours. All joints to Trap/WC/Soil pipe shall be properly sealed with sealing compound/polymer modified mortar using Dr Fixit Pidicrete UBP or equivalent in M/s Pidilite orM/s Sika Chemical, Slope of slab shall be towards and including GI pipe 50mm dia of suitable length Spout pipe. Providing 15mm protective screed with cement mortar in 1.3 with WPC (Make : Dr Fixit LW + or equivalent in M/s Pidilite orM/s Sika Chemical) within 2 to 3 days of second coat complete all as specified as per manufacturer instructions. Make : Dr Fixit Pidfin 2K or equivalent in M/s Pidilite orM/s Sika Chemical complete all specified and directed by Engineer-in-Charge. 64 Note :- The work shall be carried out by authorised and qualified applicators of the above mentioned manufacturer. 65 Dismantling of floor, hearth or wall tiling incl cement mortar bedding (but not backing) and removing rubbish off from premises & M&L forceramic coloured tiles of size 350mmx250mm/ 300mm X 450mmx7 to 8 mm thick, on vertical surfaces, set and jointed in neat cement slurry and pointed in coloured / white cement to match the tiles inc rendering 10mm thick in CM 1:4 on fair faces of brick work or concrete surfaces as in backing coat to receive wall tiles etc complete all as specified and directed. 66 Dismantling of floor, hearth or wall tiling incl cement mortar bedding (but not backing) and removing rubbish off from premises & M&L for joint free non skid coloured ceramic tiles 7 to 8 mm thick area of each tile not exc 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointedin white or coloured cement to match incl 15 mm thick screed bed in cement mortar 1:4 for layingfloor finishes complete all as specified and directed. 67 S & F in repair vitreous china squatting pan Orissa pattern size 580 x 440mm white with integral foot rests incl connecting to P or S trap and to flush pipe anti syphonage pipe etc compete including provn of lime concerte bedding and making good to floor complete all as specified and as directed. 68 S & F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/trenchesbore of pipe 75 mm with PVC clamps and saddles including taking down existing pipes and Dismantling of old unserviceable cast iron/RCC/PVC drain pipes jointed in cement mortar and taking out from trenches or walls of any bore including fittings complete all as specified and as directed 69 S & F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/trenchesbore of pipe 110 mm with PVC clamps and saddles including taking down existing pipes and Dismantling of old unserviceablecast iron/RCC/PVC drain pipes jointed in cement mortar and taking out from trenches or walls of any bore including fittings complete all as specified and as directed 70 S & F in repairs PVC (SWR) bends of any radius with access door bore of pipe 75 mm complete all as specified and as directed. 71 S & F in repairs PVC (SWR) bends of any radius with access door bore of pipe 110 mm complete all as specified and as directed. 72 S & F in repairs 125/ 110 mm bore PVC (SWR) floortrap plain with grating incl jointing with solvent cement complete all as specified and as directed. 73 S&F PVC bends 110mm boreincluding taking down existing old one complete all as specified and as directed. 74 S&F PVC bends 75mm boreincluding taking down existing old one complete all as specified and as directed. 75 S&F in repairs PVC (SWR) floor trap 75mm dia of outlet pipe, plain with grating including jointing with solvent cement complete all as specified and as directed. 76 S&F in repair stack clamps made out of 50 mm x 5 mm flat iron and 110 mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or rooffor 110 mm bore complete all as specified and directed. 77 S&F in repair stack clamps made out of 50 mm x 5 mm flat iron and 75 mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or rooffor 75 mm bore complete all as specified and directed. 78 M&L Repair of leakage/seepage from the Nahani trap/ floor trap of kitchen/ bathroom/ washbasin of the upper Qtr, in any position at any height, complete including change of floor trap, PVC horizontal pipe embeded in floor in bathroom or kitchen making good to the damaged portion of flooring, laying and matching of tiles in the existing flooring, complete all as specified and directed. 79 M&L Repair of leakage/seepage from the wall/ door bend /door tee/Y junction/ T Junction of soil pipe / waste pipe/ vent pipe of kitchen/ bathroom/WC of the upper Qtr or at the ground floor Qtr including change of any damaged soil waste pipes or fittings of any shape, specification and size, making good to the damaged portion of wall with brick work in cement mortar 1:6 or cement concrete 1:2:4 and plastering to wall in CM 1:4 and finished the surfaces matching to existing wall complete to avoid the leakage/ seepage at the site of work as directed and as specified. 80 Note for item No 78 & 79:- (a)Find out main cause of leakage and take necessary steps to resolve / rectify.(b)Replace existing tiles in case leakage through NT/FT.(c)The rate also include for provision of new NT/FT.(d)The unit rate is also deemed to be included for reqd bonding chemicals to arrest the leakage/seepage as directed by the manufacturers specification. Make : M/s Sika Chemical, M/s Pidilite, M/s Dr Fixit 81 Petty repair to internal/external water inlet GI/CPVC pipe line of any size coming from over head tank to the quarter including socket,elbow,nipple ,with repair to water blockage , pipe line leakage, cleaning internally , removing of air/dust blockageincluding concealed water tubing etc n exc 3m length of any height using scaffolding as required and making the water supply functional complete all as specified and directed. 82 Supply and fixing 15mm bore galvanized steel water tubing, medium grade with all fittings and fixed complete to walls and ceiling or laid in floors including taking up or down old steel tubing and connection complete all as specified and directed.. 83 Supply and fixing 20 mm bore galvanized steel water tubing, medium grade with all fittings and fixed complete to walls and ceiling or laid in floors including taking up or down old steel tubing and connection complete all as specified and directed. 84 S&F in repairs Stop Valve standard of PTMT any colour high pressure screwed for iron pipe and fixed.(Minimum weight 15mm-90gms) and directed. 85 S & Fin repair bib tap standard of PTMT any colour screwed for iron pipe and fixed,15 mm bore (minimum weight 90gms) complete all as specified and as directed. 86 S & F in repairs PVC low level flushing cistern 10 Lit capacity including necessary brackets incl connecting flush pipe etcand making good the disturbed surfaces complete all as specified and as directed. 87 Taking down & re fixing high or low level flushing cistren 10 ltrs capacity & connections to pipes & fixing of chain & pull or lever after cleaning inside of all dirt, scale formation, replacement of rubber washers, syphon set, flush handle, float valve,stopping of leakage etc complete all as specified and as directed. 88 S&F Rotational moulded polyethylene water storage tank of500 Ltrs capacity cylindericalvertical with closed top including 3 Nos GI check nuts and tank nipple of 25mm bore for inlet and outlet, 25mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball hoisted and fixed in position all as specified in SSR part -I including taking down old unserviceable tank complete all as specified and directed. 89 S & F in repairs bib taps short/long body cast copper alloy chromium plated fancy type screwed down screwed foriron pipe or for brass ferrule and fixed for 15 mm bore complete all as specified and as directed. 90 S & F in repairs pillar tap with capstan heads chromium plated fency type screwed down high pressure with or withoutletter Hot or Cold with long screwed shanks and flynuts screwed for galvanised iron pipe and fixed complete for 15 mm bore complete all as specified and as directed. 91 S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 meter long flexible tube and ABS wall hook including taking down existing one complete all as specified and as directed. 92 Supply and fixing in repairs plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device all as specified and directed. 93 S&F in repairs grating doom 125mm dia with waste hole of Chromium plated (Min wt 40 gms) complete all as specified and as directed. 94 S&F in repairs Overhead Shower rose ø125mm (Brass Chrome Plated)complete all as specified and as directed. 95 S & F in repairs 15 mm dia stop valves of cast copper alloy fancy type chromium plated screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe complete all as specified and as directed. 96 S&F in repairs pillar tap standard of PTMT any colour high pressure screwed for iron pipe and fixed.(Minimum weight 15mm-110gms) complete all as specified and directed. 97 S&F 150 mm dia round/square grating of CP with or without hole includingJointed to PVC pipe completeall as specified. 98 S&F in repairs 40mm bore unplasticised PVC pipe of pressure rating 10 kgf/Sqcm fixed complete to walls, ceiling or laid in floors complete all as specified and directed. 99 M&L Vitrified Ceramic tiles 10 mm thick, lightshade (square/ rectangular) polished, area of each tile not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over andincluding screed bed or bedding layer, 15 mm thick in Cement Mortar 1:6complete including dismantling of existing old flooring tiles and disposal to outside MD land complete all as specified and directed. 100 M&L Vitrified Ceramic tiles 10 mm thick, lightshade (square/ rectangular) polished, area of each tile not exceeding 0.36 sqm, in vertcal surfaces such as skirting/ dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over andincluding screed bed or bedding layer ,15 mm thick in Cement Mortar 1:6complete including dismantling of existing old tiles and disposalto outside MD land all as specified and as directed. 101 Material and labourfor 25 mm thick PCC (1:2:4) type B-1 using 20mm graded stone aggregate as in flooring surface as in level course etc including demolition of existing old cement concrete, including disposal of demolition material upto 500mtr from MD land complete all as specified and directed. 102 Supply and fixingAnodized aluminium size 605 x 605 mm snap grid frame work for false ceiling as per manufacturer instructions, with suitable size GI wire Hangers (up to 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long and6mm thick Non asbestos fibre cement building boards, fixed to sheet suitably placed in false ceiling grid made of Aluminium as per specification and drawing and including dismantling old unservicable ceiling board & frame of any type and description, complete all as specified and directed. 103 M&L for removing old existing rubbish/battered/useless mixture of the binding materials such as cement / Lime and fine aggregate (<4.5mm retained on IS Sieve), loose/unsound weaken mixture of binding materials such as cement / Lime and coarse Aggregate (>4.5mm retained on IS Sieve), fine Aggregate of any description and in any position from existing external/internal surfaces of RCC components or any surface having average profundity of 15mm (Approx height 10m from natural ground level) by hand tool that has a long metal blade with a sharp edge at the end, chisel and hammer or using robust pneumatic chisel hand tools and removal beyond MoD land including cutting of all edges, making square shoulders of the aperture, coarsen the smooth surfaces, curettage /removing of all deterioted/decayed loose surface complete all as specified and directed by Engr-in-charge. 104 M&L for cleaning and removing all corrosion scales , rust , etc using emery / wire brush and finally cleaning using rust remover & cleaning agent that is one part alkaline based material, with corrosion inhibitors and dispersing agents and supplied as a clear brown solution. The specific gravity shall be 1.2 – 1.22 @ 25°C. The pH value shall be between 9.5 to 10 and the coverage shall be 5 – 6 m2/ L as per manufacturer instructions complete all asspecified and directed by Engineer-in-charge. 105 M&L for repair to cracks and damaged existing surfaces by Hydrogen Free Expanding And Plasticising Additive . It plasticizes the mix, allowing for substantial reduction in water without affecting the fluidity, thus improving the strength and impermeability, the admixture/ additive in cement to provide non‐shrink properties Cementitious Cable Encapsulation .(a). Fixing of pvc nozzles in zig-zag fashion not more than 50cm c/c on RCC surfaces on all directions as required after drilling holes in concrete, fixing pvc nozzles with fast setting mortar and covering with renderoc plug. The size of holes shall be 20mm dia and 75mm in depthcomplete all as specified and directed by Engineer-in-Charge. 106 M&L for Shear thinning agents in RCC/ walls/ ceiling/ columns/ beams/floor/bricks cracks after opening up in “V” groove manner covering the area of 300mm from central line of crack with the depth of 8 mm complete with three components compound graded filler, E-Resins and Shear thinning agents with adjustable consistency by varying the filler component epoxy resin based complete all as specified and directed by Engineer in Charge. 107 M&L for applying 2 coats of primer slurry prior to the application of the repair mortar having multiple corrosion inhibiting synergies and which is a blend of pc graded fillers corrosion inhibiting additive and re-dispersible polymers in powder form mixed with water for application by brush to coat the reinforcement/steel within 10mm of the finish surface and where chlorides are present so as to achieve adhesion bond strength of 1 MPa to steel. Pot life of 0.5 hr @ 30°C. It shall be workable for not more than 15 minutes at same temperature. The mixed density shall be not more than 2.05. The water/powder ratio shall be 0.3 by weight complete all as specified and directed by Engineer-in-charge. 108 M&Lfor providing and fixing welded MS wire mesh weighing not less than 1Kg/Sqm of size 50mmX50mm of 2.6mm dia on the prepared surface & surface should be cleaned andbe removed from dirt, fungus and all foreign material complete all as specified and directed by Engineer in Charge. 109 M&L for providing and spraying polyamine cured epoxy coatingincorporating a special alkali reactive emulsion breaking system compoundover the plastered surface. This impervious film prevents excessive water evaporation which in turn permits more efficient cement hydration, thus reducing shrinkage and increasing durability. It shall have a specific gravity of 1.02 and the minimum application temperature shall be 10°C and the strength of concrete complies with the internationally recognised ASTM C309-90 standards typically within the range of 200 to 285 ml/sqm, SG - 1.02 including all tools and tackles complete all as specified and directed by Engr-in- charge. 110 M&L for applying Polyster Resin based Anchoring material in concrete before fixing nozzle it should typically attains a compressive strength in excess of 20N/mm @ 3 hours and and ultimate compressive strength of 70N/mm in 7 days (50mm x 50mm x 50mm)when tested as per BS 6319 Part 2 : 1983as per manufacturer instructions complete all asspecified and directed by Engineer-in-charge. 111 M&L for applying 2 coats oftwo component amine cured epoxy mastic coating usingLight brush blasting using nonmetallic abrasive leaving a clean, rough and even pattern.it should bebased on a 100% epoxy formulation and contains no solvents or water diluents. Apply two coats with brush or squeeze to the existing surface, working well into the substrate.it should achieve Compressive Strength of >70 MPa after 14days, having pot life, minutes at 27⁰C, 100 g >40 mass as per manufacturer instructions complete all asspecified and directed by Engineer-in-charge. 112 M&L for applying 20mm shear thinning fibre reinforced polymer modified , impermeable to aggressive elements, dual shrinkage compensated, cementitious repair mortarwith alkali resistant synthetic fibres for exceptional resistance cracking complies ASTM C 109 with flexural strength ASTM C 348 @ 7 days meeting 7N/sqmm, tensile strength @ 7days (ASTM C 307)> 3 N/sqmm, compressive strength of 35MPa at 7 day and 45MPa at 28 days, at the outer or inner RCC which provides excellent bond to concrete, Improves tensile and flexural properties of mortar, Versatile having specific gravity of 1.02cement sand can be used for finishing purposecomplete all as specified and directed by Engr-in-charge. 113 M&L for applying 3 coats of corrosion inhibiting, polymer matrix with excellent mechanical properties such as adhesion and elongation as waterproofing barrier coating. It should be non toxic and non-re-emulsifying. Should conform to JIS Z 1535 and IS-3085 and DIN-1048.having Hardness - Shore D scale of 20,wet density of 1.66 g/cc, flexibility at low temperatures, tensile strength > 0.4 MPa, Elongation > 20%, adhesion to substrate greater than 1.5 N/mm², waterproofing to withstand 330 KPa positive pressure and 160 KPa negative pressure, Mixing should be done by electric rotary mixers. The substrate should be free of laitance, loose concrete, dust, oil etc. if applied on screed or any other cementitious surface the surface should be properly cured prior to application complete all asspecified and directed by Engineer-in-charge 114 M&L forapplying two coat of mixture of two monomer unsaturated liquid hydrocarbon , gaseous hydrocarbon and polymesrized them to get the high polymerdispersion emulsion successfully bonded to mortar, to improve adhesion to concrete, better durability, reducedshrinkage and increased flexibility and resistant toemulsification in damp condition modified Ensuring no porosityin new/old surface, temperatures between +5°C and +35°C, Resist to penetration of CO24.600 micron , compressive strength (11.5 N/mm2) at 3days strength - 11.5 (N/sqmm ) and at 28 days - 25.30N/sqmmas per manufacturer instructions complete all asspecified and directed by Engineer-in-charge. 115 M&L for Sprinkling sand particles of saturant making mechanical key, over which applying Single component, fiber reinforced cementitious repair mortar which is reinforced with specially designed bean shaped, alkali resistant synthetic fibers for exceptional resistance to cracking for a thickness of 10 mm. water ratio of which shall be 0.16, 28 days compressive strength shall be 30 MPa,mixed density shall be 2.18 kg/ltr, flexural strength shall be 6 MPa for 7 days and tensile strength for 7 days shall be more than 2MPa.Its adhesion bond strength shall be greater than 2 MPa with creep strain reduction of 8%.Single component, fiber reinforced cementitious repair mortar.cement and sand can be used for finishing purpose. The modulus of elasticity of this product shall be 23-26 KN/mm² complete all asspecified and directed 116 Note for item No. 103 to 115 :-The work for items Srl No 103 to 115 shall be executed directly by manufacturer or through their authorized and qualified applicators,of any following manufacturer only. M/s Fosroc chemicals, M/s Thermax Limited, M/s Tiki Tar Danosa India Ltd 117 The contractor must submit MOU with manufacturer/authorized applicator at the time of sample approval. 118 The contractor shall submit performance guarantee certificate for structural repair/leakage/seepage for a period of 10 years from the certified date of completion. 119 The unit quoted rate shall be inclusive of material, all labours, tools and plants including scaffolding required for working upto 15 mtr height from natural ground level. 120 The defect liability period for the structural repair work shall be 05 (five) years from the certified date of completion of work. 121 A security deposit of value equal to 2.5% of the rate quoted against each item shall be retained from Final bill payment due to the contractor for the defect liability period. 122 The unit quoted rate is deemed to include taking up or down of water pipe, tanks, wires etc found on roof or other working areas and re-fix same at the original position after completion of work. 123 Adoption of necessary safety arrangement like safety belts, ropes, helmet, netting etc are required for safety of working labour at height exceeding 3 to 15 mtr shall be mandatory & deemed to be included in the unit quoted rate 124 Removing plant/Uprooting of vegetation growth including roots on wall/roof/parapet near pipes etc and applying acid treatment afterremoving roots for preventing regrowth and making good disturbed surfaces/area in superficial area exc 150sq.cm but n.exc 400 sq.cm and averaging depth not exceeding 10 cm by using PCC 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) or 10mm thick plastering in cement mortar 1:3 as required and finishing the surfaces to match with the existing surface complete all as specified and directed. 125 Material and labourfor Preparation of old decoratedplastered or unplastered surfaceof wall, brooming down or steel wire brushing down smoke soot, moulds mass, efflorescent , trading, oil, greasy spots and applying one coat of cement based paint complete all as specified and as directed. 126 M&L for Preparation of old decorated surfaces of wallsby using pressure washer, remove all dirt & dust ,applying one coat of wall care putty and then applying two coats of premium oil bound distemper over one coat of primer as per manufauture instruction of required shade complete all as specified and directed. 127 M&L for Preparation of old decorated wall surfaces including cleaning with water, rubbing offungus complete removal,applying two coat of weather proof paint APEXexterior wall paint including necessary preparation to give uniform and smooth finish all as specified and directed. 128 M&L for preparation of old surface of floor, any description over 10cm width or girth not otherwise described and applying two coats of durable 100% acrylic latex- based textured synthetic paint as in basket ball court / badminton court and similar works using roller/ bruss with standard specification etc complete all as specified and directed by Engr-in-Charge. 129 M&L Plain cement concrete (1:3:6) type C1 (20 mm graded stone aggregate), 75mm thick, as in plinth protection courses, top surface of concrete finished even and smooth without using extra cement,including expansion joint 10mm thick filled with mastic filling comprising of 01 part of heated blown bitumen and 3 parts of dry sandincluding demolition of existing cement concrete and disposal of demolished material upto MD land complete all as specified and directed. 130 Dismantling floor, floor hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises and Material and labour for digitalGlazed/ rustic finish ceramic coloured tiles 350x250mm/ 450 x 300 mm x 7/8 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match with tiles on vertical surface such as skirting/ dadoincluding 10mm thick 1:3 backingcoat complete all as specified and directed. 131 Taking down chowkhat or frame (wooden/steel/aluminium) not exceeding1.5 Sqm each with shutter (with out taking off shutters from the frame) all as specified and as directed. 132 S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube complete all as specified and directed. 133 S&F Factory made Solid PVC Door Shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails.MS frame shall be covered with heat moulded plain colour PVCCchannel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail.Panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitablePVCsheetbeadingand jointed together with solvent cement complete all as specified and directed. 134 S&F Butt hinges 75 mm long medium weight cold rolled stainless steel complete all as specified and as directed. 135 Supply and fixing 150 mm long aluminium anodized barrel tower bolt extruded section complete all as specified and as directed. 136 Supply and fixing aluminium handles cast type anodized 150 mm long complete all as specified and as directed. 137 S&F in repairs Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.4mm complete all as specified and directed. 138 M&L Hacking out old broken glass (any thickness, size, quality or description) from wooden frames/steel frames glazed with putty or fixed with beads and material and labour for4mm thick plain sheet glass ordinary quality and glazed with oil putty or fixed with fillets 2nd class hard wood of sectional area not exc 3 Sqcm and glass not exc 0.5 Sqm in each pane complete all as specified and directed. 139 M&L Hacking out old broken glass (any thickness, size, quality or description) from wooden frames/steel frames glazed with putty or fixed with beads and material and labour for4mm thick plain sheet glass ordinary quality and glazed with oil putty or fixed with fillets 2nd class hard wood of sectional area not exc 3 Sqcm and glass exc 0.5 sqm in each pane complete all as specified and directed. 140 Petty repair to door shutters for easy closing/opening(size upto 3 Sqm) including minor repair and easing, adjustment/aligmentto openable with accessories and including taking down and refixing, tightening of hinges or changing the position of hinges,welding of hinges door to frame adjustment of tower bolts, sliding bolts with new screws etc,complete all as specified and directed. 141 Supply and Fixing 30 mm thick factory made flush shutter solid core construction with block board core and plywood face panels, comercial type on both faces complete all as specified and directed. 142 S&F in repairs 300mm, ordinary Mild steel rat tail rod pattern springs including roller and roller plate complete all as specified and directed. 143 S&F 5mm thick rubber beading strips of entrance doors having width exc 3cm and not exc 5cm to arrest entry of insects including taking down existing one complete all as specified and as directed 144 Supply and fixing in repairs aluminum handles cast type anodised 200 mm long complete all as specified and as directed. 145 Supply and fixing in repairs aluminum handles cast type anodised 150 mm long complete all as specified and as directed. 146 Supply and fixing in repairs 150 mm long aluminum anodized barrel tower bolt extruded section complete all as specified and as directed. 147 Supply and fixing 100mm long Butt hinges medium weight cold rolledstainless steel, fixed in repair to wooden frame/welded to metal frame complete all as specified and as directed. 148 Supply and fixing in repairs butt hinges 75 mm long medium weight cold rolled stainless steel complete all as specified and as directed. 149 Supply in repair 40 mm dia cupboard knobs brass polished, complete all as specified and directed. 150 Applying silicon sealent on joints of wall, cill, jambs, roof etc complete all as specified as directed 151 S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm wood grain printed PVC sheet used instead of plain colour pvc sheet and edges will be painted to match with printed sheet complete all as specified and directed. 152 Providing and injecting chemical for post constructional Anti TermiteTreatment at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same all as specified and directed. 153 M&L for 25mm dia mild steel powder coated drapery rod cut to length required without joint in between and including Mild steel powder coated fancy type brackets etc and fixed at openings including taking down existing old one complete as directed. 154 Taking down andre-fixing the same existing aluminium door/window/partitions (each shutter arean. exc 5sqm) after carrying out ceratin repairs as required, removing the existing beading and fixing new (i.e. included change of Handles, hinges, star lock, rubber beadings, bottom bearing, clips etc) rubber beading of suitable size with adhesive, overhauling of floor springs including repairing/cleaning/ greasing etc and make the same fully functional all as specified and directed. 155 S&F in repair powder coatedaluminium framewith all fixing arrangementsfor doors, sliding windows andventilators/ partitions etcwith one or more rebates including joining cleat for fixing etc aluminium section of powder coating not less than 50 micron including taking down old one of any description completeall as specified and directed. 156 S&F in repair Powder coated anodised aluminium windows, and ventilator shutters, sliding type without sash bars, aluminium sections weighing 0.55 Kg/m inculding necessary joining cleats glazing clips, rubber packing, anoised aluminium fittings suitable lock with roller complete all as specified and directed. 157 S&F 4 mm thick sheet glass ordinary quality and glazing complete in square n exc 0.50Sqm in each pane complete all as specified and directed. 158 Supply and Fix in repair for 10-12mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work including taking down old one of any description complete all as specified and directed. 159 S&F in Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face& 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and directed. 160 S&F in repair solar control interior/ exterior window /door frosted glass film 50 micron reflective type (gareware sun control or equivalent) applied to old glass surfaces using adesive/ solvent with approved procedures to prevent the formation of air cleaningbubbles , wrinkkes , bilsters and other defectsetc complete all as specified and directed. 161 Supply & Fixing of UPVC glazed 3 track-2 panel sliding windows with mesh made out of multi chambered uPVC sections with TPE gaskets having isolated drainage and reinforced with Galvanized iron profiles throught out the window. The outer frame having an overall size of 108 x 48 mm with reinforcement of 1.2mm thickness and sash with overall size of 38 x 61 mm with reinforcement of 1.2 mm thickness mesh sash of overall size 38 x 58mm Fiber mesh reinforced with 1.2 mm of GI. Glazing bead for fixing of glass shall be of size 16mm x 19mm and TPV gasket. Windows will be provided with 5mm thick plain float glass, With Astrapia hardware or equivalent & Single point locking system of flush lock. Wall thickness of frame & sash shall be 2-2.2mm complete all as specified and directed. 162 Complete removal of existing water proofing treatment of any description and in any position including PCC padding any thickness and cleaning, wire brushing, watering & removal of debris outside MOD land.NOTE :-Unit rate quoted shall also include for removal of PVC water storage tank wherever existing carefully and refixing at the same or other position after completion of roof repair work 163 M&L Cutting out cracks to V-section in existing roofs or terracing, cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand 1:1 (by weight) complete all as specified and directed. 164 Roughening surfaces of old concrete floors by picking, sweeping clean and washing down with waters to remove dusts etc. complete all as specified and directed. 165 M&L for Brushing neat cement slurry with 3kg/sqm all as specified and directed. 166 M&L PCC 1:2:4 type B-0 using 12.5 mm graded crushed stone aggregate as in concrete padding laid to required slope incl finishing the concrete surface fair and even without using extra cement complete all as specified and as directed. 167 M & L for 10 mm thick screed bed or bedding layer of mortar in cement mortar (1:4) for laying roof finish as padding finished with liquid WPC as per manufacturer instructions, complete all as specified and directed NOTE :- Integral WPC shall be measured and paid separately. 168 Apply oil bound bitumen primer @ 0.40 Litre / Sqm manufactured by the same agency as that of APP with density of 0.87 to 0.89 Kg / Litre at 25 degree Celsius on the prepared dry roof surface complete all as specified and as directed. 169 M&L APP polymeric membrane min weight 3.0kg/sqm and minimum 3mm thick reinforced with polyster non woven fabric(wt not less than 150 gms/sqm laid on primed surfaces by torch application method complete all as specified and directed. 170 M&L for preparation of new surfaces of any description not otherwise described over 10cm width or girth and applying two coats of solar reflective aluminium paint @ 0.10 kg/sqm of membrane surfaces complete all as specified and directed. 171 Raking out joints / pointing to squared rubble masonry coursed or uncoursed built in cement mortar or cement lime mortar complete all as specified and directed. 172 Keyed pointing on squared rubble masonry coursed or uncoursed (Bangalore Pattern) in cement mortar 1:4 complete all as specified and directed. 173 Supplying and laying of 25mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and including taking out old steel/plastic/cpvc water tubing and connections complete as directed. 174 Supplying and fixing in repairs of 25mm outer dia Female Brass Threaded Adaptor (FTA/ FBTA CPVC complete all as specified and directed. 175 Supplying and fixing in repairs 25mm outer dia CPVC brass elbow all as specified and directed. 176 S&F Rotational moulded polyethylene water storage tank of1000 Ltrs capacity cylindericalvertical with closed top including 3 Nos GI check nuts and tank nipple of 25mm bore for inlet and outlet, 25mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball hoisted and fixed in position all as specified in SSR part -I including taking down of old unserviceable tank complete all as specified and directed. 177 Supply and fixing in repairs 20mm dia gun metal gate valve with iron wheel screwed both ends for iron pipe complete all as specified and directed. 178 S&F in repairs of swivel Shower with arm of PTMT any colour and 195mm long bend of 45 degree with flange for fixing with 15mm pipe (Minimum weight 15mm-90gms) complete all as specified and directed. 179 S&F in repairs Vitreous China urinals, half stall Urinal type (back or corner wall type), complete including providing and fixing plugs, Urinal spreader, CP push cock, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe, complete all as specified and directed. 180 S&F in repair vitreous China urinals, bowl type (back or corner wall type), complete including providing and fixing plugs, Urinal spreader, CP push cock, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe complete all as specified and directed. 181 S&F in repairs of Push tap any colour high pressure of PTMT screwed for iron pipe and fixed, (Minimum weight 15mm-47gms)and complete all as specified and as directed. 182 S&F in repairs 40 mm Waste coupling fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed one complete all as specified and as directed. 183 S&F 32 mm Waste Coupling fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed including taking down existing old one complete all as specified and as directed. 184 S&F in repairs of chromium plated tubular towel rail 20 mm dia brass D type 60 cm long between flanges complete all as specified and as directed. 185 S&F in repair Toilet paper holder box type of vitreous china fixed to walls with chromium plated (CP) brass screwsand complete all as specified and as directed. 186 S&F PVC connections 15mm size with PTMT nuts of length 450 mm including taking down existing old one complete all as specified and directed. 187 Supplying and laying of 20mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and taking out old steel/plastic/cpvc water tubing and connections complete all as specified and directed. 188 Supplying and fixing in repairs of 20mm outer dia Female Brass Threaded Adaptor (FTA/ FBTA CPVC complete all as specified and directed. 189 Supplying and fixing in repairs 20mm outer dia CPVC brass elbowall as specified and directed. 190 Petty repair to toilet floor, bathroom, kitchen, etc seepageincluding sunken portion treatment with apply water proofing compound including repair and arrest the leakage to floor trap,nahani trap , grating and applying white cement etcmaking good to the damaged portion of flooring, laying and matching of existing flooring, complete all as specified and directed. 191 S&F CP sink cock with swinging casted round shape spout screwed down screwedfor iron pipe in repairs 15mm bore including taking down existing one complete all as specified and as directed. 192 S&F in repair Chromium platedsoap dishincluding fixing arrangement complete all as specified and directed . 193 S&F Towel Ring roundn exc 20cm dia stainless steel material fixed to wall with brackets including taking down existing one all as specified and as directed. 194 S&F PVC body cabinet box mirror of size 350mm X 450mm X 100mmPTMT alloy of approved pattern and design including taking down existing one complete as directed. 195 S&F in repairs Glass self assembly of 12mm thick andn exc 60cm length, 15cm wide with stainless steel brackets, stainless steel railing in bathroom and fixed to wall with brackets complete all as specified and as directed 196 S&F 300mm arc size, 5mm thick corner glass shelf with stainless steel brackets, stainless steel railing in bathroom and fixed to wall with brackets including removing the existing fitting as per manufacturers instructions and as required at site complete all as specified and as directed 197 S&F in repairs Wash basin vitreous china (flat back or angle back type) size 580x400mm including taps wastechain and plug and porceline stopper but brackets including cutting for and pinning inends of brackets or erecting stand with waste pipe, complete all as specified and directed. 198 S & F in repair waste coupling 32 mm dia of PTMT (half or full threaded) minimum weight 45 gram complete all as specified and as directed. 199 S &Fin repairs PVC connection pipe 15 mm dia, 600 mm long with check nut and bolt with washer complete all as specified and as directed. 200 S&F in repairs PVC waste pipe 32/40mm bore for WHB, Urinal & Sink complete all as specified and as directed. 201 S & F in repairs vitreous china wash down water closet (Pedestral pattern) EWC white incl plastic water closet seat cover and mild steel chromium plated or aluminium hinging device and connecting to P or S trap incl connecting flush pipe with flushing rim complete all as specified and as directed. 202 M&L Petty repairs to leaking water in bib taps, pillar cock, stop cock, angle valve, concealed stop valve, bottle trap of any description by changing thePVC washers/ Sheet washers,spindle brass,jumper brass or any other minor accessories items etc (incl taking down and refixing) complete all as specified and directed 203 S&F in repairs CP 2 way bib cock with wall flange fancy type chromium plated screwed down screwedfor iron pipe for 15mm bore complete all as specified and as directed. 204 S&F CP Concealed stop cock, Regular body with adjustable wall flange screwed down screwedfor iron pipe15mm bore including taken down existing one complete all as specified and as directed. 205 M&L forRepair to ends of chajjas/ parapets by removing old concrete,loose material &cleaning of the reinforcement and finishing the surface with rich cement mortar 1:3 , finished fair & even and making good with existing finishes complete all as specified and as directed.Note: Rate quoted by the tenderer shall be deemed to inclusive of double steel scaffolding. 206 Taking down cement plaster on brick or stone walls, or concreteetc., including raking out joints, hacking for key, scrubbing down with water, etc., including removal of rubbish off the premises and leaving the work clear of any plastering and Material and labour for Rendering 15 mm thick in two layers onbrick or stone or concrete surfaces,first coat 10mm thick in cement mortar1:4 and 2nd coat 5mm thick in cement mortar1:4 finished even and smooth without using extra cement completeall as specified and directed.Note :-(a) The unit rate quotedis deemed to include for removal of accumulated earth of any width and depth upto 15 cm cleaning/cutting the grass with hand operated petrol/kerosene driven grass cutting machine and removing the grass waste around 3 m from plinth protectionto outside MD land. 207 M&L preparation of newly plastered surfaces and applying three coats of white washing on walls surfaces complete all as specified and directed. 208 M&L Machine cut kota stone slab 20-25 mm thick as in flooring, laid over and incl 20 mm thick screed bed in CM 1:3 set and jointed in neat cement slurry and pointed with cement and pigment to match the shade of the slab incl rubbing and polishing including demolition of existing cement concrete and disposal of demolished material upto MD land complete all as specified and directed. 209 M&L applying two coat of cement based paint over a coat of primer, including preparation of newly plastered wall surfaces of any description, complete all as specified and as directed. 210 S&F in Solid PVC Wall Lining / panellingconsisting of5mm thick wooden colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing including taking down old one complete all as specified and directed. 211 S&F in 5mm thick PVC sheet fillet of width35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing including taking down old one complete all as specified and directed. 212 S&F in repair manually operated polyester fabric vertical venetian blinds of approved colour and pattern of any size and thickness of 0.45mm (+/-0.05mm) including high strength aluminium alloy channel fixing with two Nos clamp including all connected fittings and fixtures for windows,ventilators etc complete all as specified and directed. 213 Supply and fixing in repairs 7 feet 4 pipespulley operated cloths drying system consisting of aluminium pipe of outer dia 22mm, inner dia 19.80mm,made up of detrin with rope guide mounted on channel pair of length 24 feet (distance between two pipes is adjustable) locking system to hide rope knot, channel to be mounted or fixed with self taping screws provided in kit. Rope will be HDPE double core of 4mm dia fixing to ceiling as specified and directed by Engr-in-Charge and minimum weight of one pipe shall not be less than 0.20kg/, minimum weight of rope shall not be less than 7700Gms/unit. Make : Easydry or equivalent. 214 Grinding of existing mozaic/kota stone/tiles in wall/flooring including mirror polishing, cleaning of tiles/granite and joints filling and apply white cement,including grouting of floor trap surroundings with white cement complete all as specified and directed. 215 S & F in repair 18/19 mm thick ,water proof plywood , fixed to Cupboard work in any position with nails including removal of old boards of any description complete all as specified and as directed. 216 S&F PVC beading for cupboard work, colour and pattern as approved including taking down existing one complete all as specified and as directed 217 S&F Decorative laminates of 0.90 mm thick type matt finish, colour and pattern as approved. including taking down existing one complete all as specified and as directed. 218 S&F Stainless steel spring hinges of size and approved pattern and make suitable for base/wall unit of cupboard including taking down the existing one complete all as specified and directed. 219 S&F Stainless steel handles of size 100 mm of approved pattern and make suitable for Base/Wall unit of modular kitchen including taking down the existing one complete all as specified and directed. 220 S&F Continuous (piano) hinges, stainless steel bright finish or electrogalvanised of 40mm width of flaps (when open) complete including taking down old all as specified and as directed. 221 S&F in repairsstainless steel wire Bottle pull out basket (storagebasket) pull out type, of suitable size 100mm height of grade 304 with necessary fixing clips etc complete all as specified and directed. 222 S&F in repairs stainless steel wire Thali basket (storagebasket ) pull out type,of suitable size 150mm height of grade 304 with necessary fixing clips etc complete all as specified and directed. 223 S&F in repairs stainless steel wire saucer basket (storagebasket) pull out type, of suitable size 200mm height of grade 304 with necessary fixing clips etc complete all as specified and directed. 224 S&F Stainless steel telescopic slider of 500 mm of approved pattern and make suitable fordrawer in base unit of modular kitchen including taking down the existing old one complete all as specified and directed. 225 S&F Stainless steel handles of size 150 mm of approved pattern and make suitable for Base/Wall unit of modular kitchen Including taking down the existing old one complete. 226 S&F Magnetic catches with 8mm dia steel ball and brass body and striking plate including taking down old complete all as specified and directed. 227 M&L for 18-20mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills,cooking platforms, shelves in cupboard,handwash places and like including necessary cutting and grooving to wallsand making good by pointing in cement mortar (1:2) using admixture of pigment to match with shade of graniteover andincluding cement screedbed Cement Mortar (1:6) 15 mm thickcolourof granite as approved incl removal of old flooring of any description all as specified and directed.NOTE : (i)Dismantling of stone slab and tiles laid, bedded and pointed in any mortar of any discription of thickness in floor(ii)The unit rate is deemed to be included for rounding to edges of stone slabs. 228 Petty repairs to refixing the existing Wash hand basin and Sinks made of stainless steel 1mm thick kitchen flat back including fixing cantilever CI/Angle iron brackets embedded in concrete block including connecting waste coupling 32mm bore, including bedding, waste fitting, waste pipe in cement mortar on to dwarf wall and connecting union to pipe, filling gap in white cement and all necessary fittings to fixed in repair(including taking down and refixing the same position) complete all as specified and directed. 229 S&F sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortarto dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm fixed in repairsall as specified and directed. Make : M/s Diamond / Nirali / Amco / TATA or equivalent 230 S&F Plate rack of size 65 cm x 96 cm heavy duty made of stainless steel fixed in repairs complete all as specified and directed. 231 Petty repair to wall mixer,basin mixer,sink mixer etc including replacement of spindle brass, Jumper brass, rubber washer, head included taking down and refixing etc all as directed. 232 S&F in repair Brass Chromium plated wall mixer for mixing hot & cold water screwed down for 15mm bore iron pipecomplete all as specified and directed . 233 S&F Sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs,washers and wastes; including bedding in cement mortar to dwarf wall orincluding fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm fixed in repairsall as specified and directed. 234 Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding,buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangementincluding taking down/ dismantling of old one complete all as specified and directed. 235 M & L for 0.50mm thick Pre painted Galvalume aluminium zinc coating GI based corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws incl dismantling of old corrugated AC/fibre/GI sheet of any pattern in roof including ridge complete all as specified and directed. 236 Dismantling wrought iron or mild steel work of any description and in any position complete all as specified and directed. 237 S&Fin framed work as in doors or gates of angle,tubes or other section with gusset plates, rails, braces,guard bar etc., complete, to be prepared for hanging or sliding with and includinghinges or steel hanging door fittings (exclusive of steel sheeting or other covering) and hanging; also fastening and fixing Fe 410 -W (Gde- E- 250) quality-A complete all as specified. 238 M&L for welding in repairs not exceeding 10 Cm length & thickness of metal to be welded not exceeding 6mm complete all as spcified and directed. 239 S&F welded steel wire fabric cut to length, bent to shape required and tying with and including annealed mild steel not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel membersnot exceeding 4kg/sqm including taking down old one complete all as specified and directed. 240 M&L pereparation for new steel surfaces and iron work of any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamal paint over a coat of red oxide primer complete all as specified and directed. 241 Forming Construction joints 30 mm deep x 10 mm wide filled with sealing compound grade A complete all as specified and directed. 242 M&Lin repairs Pre-cast PCC 1:3:6 type C1 (20 mm graded agg) cement concrete block masonry with solid blocks exc. 10cm in width and set in cement mortar 1:6 including demolition of old brick work / stone masonry/PCC block built in cement mortar of any description as specified and directed. 243 M&L rendering 15 mm thick in CM 1:6 on brick surfaces finished even and smooth with out using extra cement all as specified and directed. 244 S&F in double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel covert governing pivot made of brass, other parts made of mild steel heavy duty including taking down existing wire cloth all as specified and directed. 245 S&F in repairs 0.56 mm thick Plain, Aluminium sheeting, Alloy 31000 H4 in ridges, hips, valley gutter, drip and straight flashing (length and girth as fixed), complete all as specified and as directed. 246 Supply only integral water proofing compound of approved make all as specified and directed. 247 Cutting holes in stone wall exc half brick and n.exc one brick in cement mortar for inserting hold fasts/lugs and making good dismantled portion in cement mortar 1:3 or 1:2:4 type B-1 concrete using 20mm graded aggregate as required complete all as specified and as directed. 248 Renewingcement concrete tiles/interlocking tilesin patches, area n exc 5 Sq.m. including removing and cleaning old tiles, preparing beds and laying or setting, jointing and pointing new or old tilescomplete all as directed.Note : The rate included for cutting out broken tiles, removing and cleaning loose tiles, preparing bed removing rubbish, removing and replacing old with new tiles to match, complete with all cuttings etc, that may be required. New tiles requiredis deemed to be included in quoted rate all as directed. The unit rate is also including necessary beding in cement mortor/Sand filling complete all as specified and directed. 249 Repair, maintenance and making the continuity of supply after rectifying the defects of the electrical items such as light point, fan point, call bell point, socket point 5A/15A, switches, sockets, regulator, lamp holder, brackets, bell, buzzer, push button, batten, ceiling rose, pendent, any type of MCBs, DBs any type of light fixtures, any type of lamp, ceiling fan, exhuast fan, geyser, capacitor, replacement of fuse wires and all elcectrical accessories in day to day/door to door maintenance including reconnection with S&Fsmall pieces of elctrical cable of size upto 10 Sqmm single core and length not exceeding 0.50m, complete all as specified and as directed.Note:(i)Any major items required to be repaired/replaced will be measured and paid under relevant items as supply only.(ii)Cost of labour for replacement/ attending five complaints in same building number will be treated as one job 250 Note for item No 249:- (a)The above job shall be carried out by a trained electrician having ITI in electrical, documentary proof of the education of tradesman shall be producedto Engr-in-Charge before commencement of work. 251 (b) All bldg light complaints including service connection, sub main & internal electric for entire OTM and Md accn at CQAE shall be attended 252 (c) Record of complaints/complaint slip showing qtr No, bldgs No, nature of job supported with users signature shall be prepared as per format as directed by Engr-in-charge & will be deposited to concerned JE E/M within 24 hrs. 253 (d)All sort of petty T&P items such as PVC insulation tape, ladder, galvanised screws, nuts, bolts, washers etc. required to accomplish the job shall be provided by the contractor without any extra cost to deptt. 254 (j)In case of any delay in attending the complaint more than 12 hrs after handing over routine/urgent complaints, the contractor shall be liable to pay the penalty as described in penalty clause given here as under. 255 (k)The penalty shall be applicable to the contractor if the delay is noticed by the Engr-in-Cahrge more than twelve hrs after handing over works of urgent/ routine nature to the contractor. The Engr-in-Chargeshall handover the slip containing specification of work to the contractor by lodging the time and signature of contractor shall be obtained on slip.The contractor shall attend the complaint immediately and shall report to Engr-in-Charge with in 12 hrs. The contractor will keep his tradesmen in stand by for attending any routine / urgent works from the executive.If the nature of job is such that the work cannot be completed within period of 12hrs then the facts shall be brought to the notice of the GE/Engr-in-Chargeand the period for the working to the complaint shall be decided by the GE/EIC. If the delay is more then twelve hrs period and the GE is not satisfied with the reason for delay then penalty at the rate of Rs 50/- per job shall be deducted from the dues of the contractor. Please note that this penalty is exclusively other than the condition 67 of IAFW - 2249 and shall be treated as interim condition of the contract and shall be enforce above as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt. 256 (l) The decision of the Accepting Officer in this regard shall be final and binding. 257 Supply only switch piano flush type 5 Amps240 volts single pole one way, complete all as specified and directed. Make : Anchor, Havells, L&T, Indoasian 258 Supply only switch piano flush type 5 Amps240 volts single pole two way, complete all as specified and directed. Make :Anchor, Havells, L&T, Indoasian 259 Supply only switch piano flush type 15 Amps240 volts single pole one way, complete all as specified and directed. Make : Anchor, Havells, L&T, Indoasian 260 Supply only shuttered socket outlet 3 pin 5 Amps, flush type, complete all as specified and directed Make :Anchor, Havells, L&T, Indoasian 261 Supply only shuttered socket outlet 2 in 1, 5 pin, 5 and 15 Amps, complete all as specified and directed Make :Anchor, Havells, L&T, Indoasian 262 Supply only switch socket combination out let 3 pin 5 Amps, flush type, complete all as specified and directed. Make :Anchor/Havells/L&T/ Indoasian 263 Supply only switch socket combination out let 2 in 1, 6 pin 5 and 15 Amps, flush type, complete all as specified and directed.Make :Anchor/Havells/L&T/ Indoasian 264 Supply only Ceiling rose 3 plates flush type 6 Amps,250 volts ACISI marked, complete all as specified and directed 265 Supply only 7 watt LED lamp, complete all as specified and directed. Make : Philips/ Bajaj/ Crompton 266 Supply only lamp holder, insulated body, cord grip pattern SP 230 volt, complete all as specified and as directed. 267 Supply onlyPVC insulated FRLS PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, 4 Sqmmof single core, complete all as spcified and directed. Make : Havells/ Polycab/ Plaza. 268 Supply only metal clad switch socket single pole and neutral enclosure withtwo pin and earth plug and socket complete with one single pole MCB 20A concealed in walls. Make : Legrand/ L&T/ Indo Asian 269 Supply only plug top 3 pin 15 AmpsAC 230 volts, complete all as specified and directed. Make : Havells/ Cona/ Plaza 270 Supply only electronic LED driver 10/12 W suitable for round ceiling light indoor fitting of make Philips/ crompton/ Bajaj, complete all as specified and directed . 271 Supply only rigid, non-metalic, PVC conduit pipe, ISI marked, 32 mm bore, including bends, saddles, accessories, complete all as specified and as directed. Make : Avon plast/ supreme/ Diplast 272 Supply onlysinglepole MCB 6 to 32 Amps, 240 v, 50 Hz ACsuitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996, completeall as specified and directed.Make : Legrand/ L&T/ Indo Asian 273 Supply only electronicfan regulator 230 volts, step type socket type, hum free 100/240 watt , complete all as specified and directedMake :Havells / Anchor/ crabtree/Indoasian 274 Supply only 2.5 mfd condensor for ceiling fan, complete all as specified and directed. Make : Epcos/ Asian/ Tyton 275 Supply only rigid, non-metalic, PVC conduit pipe, ISI marked, 25 mm bore, including bends, saddles, accessories, complete all as specified and as directed. Make : Avon plast/ Supreme/ Diplast 276 Supply only 4 mfd condensor for exhaust fan, complete all as specified and directed. Make : Epcos/ Asian/ Tyton 277 Supply only electronic LED driver 36/40 W suitable for 2 x 2 ceiling light indoor fitting of make Philips/ crompton/ Bajaj, complete all as specified and directed . 278 Supply and Fixingbakelite sheet not less than 3 mm thick ofsize up to 1 Sqft as per site requirement, including refixing of old/ fixing of new Switch/socket/regulator etccomplete all as specified anddirected. 279 Supply only electronicfan regulator modular type 230 volts, step type socket type, hum free 100/240 watt, complete all as specified and directed.Make :Havells / Anchor/ Crabtree. 280 Supply only TPN, MCB 20 to 32 Amp, 240 v, 50 Hz ACsuitable for ‘C’ curve, 10 KA breaking capacitycomplete conforming to IS 8828 of 1996, all as specified Make : Legrand/ L&T/ Indo Asian 281 Supply only bell push, piono type 5/6 Amp, complete all as specified and directed.Make : Anchor/ Cona/ Havells/ Indoasian 282 Supply only PVC gang box suitable for 05 Amp SS , complete all as specified and directed . Make. Cona/L&T/Anchor 283 Supply only PVC Casing & Cappingof 15 mm (width), complete all as specified and directed. 284 Supply onlymodular PVC box 2 module, complete all as specified and directed. Make : Legrand /Crabtree/ Anchor/Indoasian 285 Supply only plug top 3 pin 5 AmpsAC 230 volts, complete all as specified and directed. Make : Havells/ Cona/ Plaza 286 Supply only electric bell, AC 230 volt, single pole Ding Dong type complete all as specified and directed. Make :Anchor/Havells/L&T/ Indoasian 287 Supply onlyTPN, MCB 40 to 63 Amp, 240 v, 50 Hz ACsuitable for ‘C’ curve, 10 KA breaking capacitycomplete conforming to IS 8828 of 1996, all as specified Make : Legrand/ L&T/ Indo Asian 288 Supply only PVC gang box suitable for 15Amp SS , complete all as specified and directed . Make. Cona/L&T/Anchor 289 Supply onlyPVC insulated and FRLS PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, 2.5 Sqmm single core,complete all as spcified and directed. Make : Havells/ Polycab/ Plaza 290 Supply only PVC Casing & Capping of 25 mm (width), complete all as specified and directed. 291 Supply onlyPVC insulated and FRLS PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, 1.5 Sqmm of single core, complete all as spcified and directed. Make : Havells/ Polycab/ Plaza. 292 Supply onlymodular switch1 way 6 Amp.1 module , complete all as specified and directed.. Make : Legrand/ Crab tree/ Anchor/ Indoasian 293 Supply onlymodular Socket, 6A - 2/3 pin combined 2 module, complete all as specified and directed.. Make : Legrand/ Crab tree/ Anchor/ Indoasian 294 Supply onlymodular switch1 way 16 Amp.1 module, complete all as specified and directed.. Make : Legrand/ Crab tree/ Anchor/ Indoasian 295 Supply only modular Socket, 16A - 3/5 pin combined 2 module, complete all as specified and directed.. Make : Legrand/ Crab tree/ Anchor/Indoasian 296 Supply onlymodular white cover plate with frame,3 module, complete all as specified and directed. Make : Legrand/ Crabtree/ Anchor/Indoasian 297 Supply only modular white cover plate with frame,4 module, complete all as specified and directed.. Make : Legrand /Crabtree/ Anchor/Indoasian 298 Supply onlymodular white cover plate with frame,6 module, complete all as specified and directed.. Make : Legrand /Crabtree/ Anchor/Indoasian 299 Supply onlymodular white cover plate with frame,08 module, complete all as specified and directed.. Make : Legrand /Crabtree/ Anchor/Indoasian 300 Supply onlymodular white cover plate with frame,12 module, complete all as specified and directed.. Make : Legrand/ Crabtree/ Anchor/Indoasian 301 Supply onlymodular PVC box 4 module, complete all as specified and directed. Make : Legrand /Crabtree/ Anchor/Indoasian 302 Supply only switch socket combination outlet 3 in 1/ 3 pin 3 and 5 Amps flush type with box, complete all as specified and directed. 303 Supply only switch socket combination outlet 5 in 1/ 5 pin 5 and 15 Amps flush type with box, complete all as specified and directed. 304 Supply onlymodular PVC box 3module, complete all as specified and directed. Make : Legrand /Crabtree/ Anchor 305 Supply only PVC Casing & Capping of 20 mm (width), complete all as specified and directed. 306 Supply onlyPVC insulated and FRLS PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, 6 Sqmm Single core, complete all as spcified and directed. Make : Havells/ Polycab/ Plaza. 307 Supply only SPN MCB 40 Amp, 240 v, 50 Hz ACsuitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996, all as specified and directed. Make : Legrand/ L&T/ Indo Asian 308 Supply only insulation tape 25 mm width 10m long (ISI Marked), complete all as specified and directed. 309 M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 Sqmm drawn through in and incl suitable size surface PVC Conduit/ existing concealed conduit and all accessories fixed to wall/floors along with 6 Sqmm surface PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size.Note: (a)2 runs of 6 Sqmm cable along with one run of 6 Sqmm cable for earth conductor shall be measured as one lengthMake:- Havells/ Polycab/ Plaza. 310 S&F in replacement factory madepowder coated distribution board SPN 12 way double door,includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DBall as specified and conforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian 311 S&F in replacement distribution board MCCB four pole, 100 Amp ultimate breaking capacity 16 KAconforming to IEC -61439-1, complete all as specified and directed. Make : Legrand/ L&T/ Indo Asian 312 S&F in repairs 35/36 W (WW) LED recessed type 2x2 luminaire with classic design & glare free soft illumination. housing with white high reflection powder coated (RAL9016) CRCA sheet. Glare free, Opal diffuser for symmetrical light distribution fixed in separate CRCA sheet frame held in with housing by screws for easy maintenance. High efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle of 100° to ensure better uniformity. Powered by an independent Isolated, SELF Output electronic LED driver (SMPS based constant current supply) efficiency of 85% with built-in Surge protection 3Kv. System Lumen Output of 3000 lumens.Make : Philips/ Bajaj/CG/Havells. 313 S&F in repairof new PVC conduit medium grade of size 25mm on wall /roofwith help of screw and GI shaddle including fixing of existingserviceable copper /aluminium conductorand all fitting fixture such as Tee, Elbow and lapping, completeall as specified and as directed. Make : Supreme/Diplast/Avon plast 314 S&F in repair of new PVC conduit medium grade of size 20 mm on wall /roofwith help of screw and GI shaddle including fixing of existingserviceable copper /alluminium conductorand all fitting fixture such as Tee, Elbow and lapping,completeall as specified and as directed. Make : Supreme/Diplast/Avon plast 315 S&F in repairs LED bed side light /wall light/study lightenvironmentel friendly energy effcient of capacity3 W warm whiteetc,inbuilt drivercomplete with all accessories internally pre-wired swing type and including connecting up towith twin core twisted flexible copper conductor cable with suitable size complete all as directed . Make : Bajaj/ Philips / Wipro/CG 316 Supply & Fixing in replacement of electronic LED driver 2/3 W suitable for bed side light fitting as per site requirement complete all as specified and directed . 317 Taking down aluminium/copper point wiring & including hard wood battens, surface conduit and board/ blocks etc or through conduits for light, socket or power point, fan point complete and making good the disturbed plaster surfaces of wall, floor, ceilingand painting 2 coat of white wash/distamber to match the existing surface, complete all as specified and directed. 318 M & L for Point wiring with PVC insulated FRLS 1.5 sq mm multi stranded copper conductor cable 1100 Volts grade drawn through and including surface PVC conduit/existing concealed conduit/PVC casing-caping ets as per site requirement onwalls / roofs / floors / ceiling etc and including provision of 1.5 sqmm copper cable as earth continuity conductor and connected to common earth dolly with all fitting and fixing accessories including sunk in cast iron / pressed steel terminal boxes (duly painted with two coats of anti corrosive paint out side and two coats of aluminium paint inside ) with 3.0 mm thick hylum brand laminated white bakelite sheet cover for mounting switches, sockets, fans regulators etccomplete for the following :-Make of wire: Polycab/Plaza/HavellsNote: (a) Switches, sockets outlets, Light fittngs, fans, bells & regulators shall be measured and paid for separetely). 319 All as per item No. 318here in before but forOne light point/fan point controlled by one way 5 Amp switch. 320 All as per item No. 318here in before but forOne light point controlled by two way 5 Amp switch. 321 All as per item No. 318here in before but for one bell point controlled by one way bel push. 322 All as per item No. 318here in before but forOne 3 pin socket out let 5 Ampon the same board 323 All as per item No. 318here in before but for one switch socket outlet 3 pin 5 Amps on independent board 324 All as per item No. 318here in before but for Wiring with 2.5 Sqmm copper multistranded unsheathed cable and2.5 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently etc complete all as specified and directed. 325 All as per item No. 69here in before but for Wiring with 4 Sqmm copper multistranded unsheathed cable and4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently etc complete all as specified and directed. 326 Supply and Fix switch piano flush type 5 Amps240 volts single pole one way, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian 327 Supply and Fix switch piano flush type 5 Amps240 volts single pole two way, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian 328 Supply and Fix switch piano flush type 5 Amps240 volts bell push, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian 329 Supply and Fix shuttered socket outlet 3 pin 5 Amps, flush type, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian 330 Supply and Fix shuttered switch socket outlet 3 pin 5 Amps, flush type, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian 331 Supply and Fix shuttered socket outlet 2 in 1, 3 pin, 5 and15 Amps, complete all as specified and directed.Make : Anchor/Havells/L&T/Indoasian 332 S & F2.5 mfd condensor for ceiling fan, complete all as specified and directed. Make : Epcos/ Asian/ Tyton 333 S & F ceiling rose surface bakelight two to three terminal complete all as specified and directedMake : Anchor/Havells/L&T 334 S & Felectric bell, AC 230 volt, single pole Ding Dong type complete all as specified and directed. Make :Anchor/Havells/L&T 335 S & Ffan regulator 120W,for ceiling fan complete all as specified and directed Make : Anchor/Havells/L&T 336 Supply and Fixing in repairs of 4 feet surface mounted batten type luminaire , lumen output of 2000 lumens, high efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle not less than 120° to ensure better uniformity with an operating voltage range from 140V-270V. The luminaire shall have a white extrusion housing with a poly carbonate diffuser to provide uniform light and sleek design with width not more than 22 mm. The luminaire shall have a CRI >80, Color temperature 6500K, THD <10% and PF >0.95,SDCM<5, IP20, IK02, Operating Temperature: -10 TO + 45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-55 HZ. The luminaire shall have flicker content<5% and shall have high and low cut off with auto restart feature.Driver Safety requirement stds: IS 15885-2-13. The luminaire shall be EMI/ EMC compliant and shall have a internal surge protection of 4 KV. The luminaire shall have Class-1 Electrical insulation, Class-B serviceability .The luminaire and driver shall be BIS approved, complete all as specified and directed.Make : Philips/ Bajaj / CG/Havells. 337 Supply & fix in repair decorative surfacemountedultra slim Square/Roundprofile 18 W LED(WW/WH) lighting fixture Square shape with extruded polycarbonate, environmental friendly, energy efficient ready to use pack of18 Watt and includingcosidering material & labour forfixing ceiling hight upto 7.5 Mtr, complete all as per site requirementand directedMake : Philips/ Bajaj / CG/Havells. 338 M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 Sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with 6 Sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing old sub main wiring of any size.Note: (a)2 runs of 6 Sqmm cable along with one run of 6 Sqmm cable for earth conductor shall be measured as one lengthMake:- Havells/ Polycab/ Plaza. 339 S&F in replacementfactory madepowder coated distribution board VTPN, 4 way double doorMCCB DB includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DBcomplete all as directedMake : Indoasian/ Havells/ Legrand. 340 S&F in replacement on distribution board MCCB four pole, 63 Amp ultimate breaking capacity 16 KA conforming to IEC -61439-1, complete all as specified and directed.Make : Havells/ L&T/ Indoasian 341 S&F as in repair PVC casing capping medium grade of size 32 mm on wall /roofwith help of screw including serviceable copper /aluminium conductor and all fitting fixture such as Tee, Elbow and lapping,completeall as specified and as directed. Make: Polycab/ Modi/ Presto Plast 342 M&L for cutting of hole through brick wall with the help of Core cutting machineincluding providing, fixing and removing shoring,cleaning,internal plastering and removing surplus hard core,rubbish not exceeding 50 mtrs including fixing of exhaust fan of size 250-450 mm all as specified and as directed. 343 M&L forin repair louver made of galvanised steel sheet suitable for 300 mm size exhaust fan, fixed on wall including necessary fixing arrengement up to height 11 mtrcomplete all as specified and directed.Note : All safety measures shall be the responsibility of the contractor. 344 Supply and fixingExhaust fan 300 mm sweep 230/ 240 volt AC single phase PVC body 1400 RPM including necessary nut, bolts / screws including taking down existing one writing MES No. with synthetic enamel paint all specified and directed.Make : Havells/Bajaj/ Orient/USHA.Note:-Old Unserviceable Exhaust fan shall be deposited to MES store yard without any extra cost to the deptt. 345 M&L in repairfor stainless steel wire cloth 0.63 mm dia of wire and average width of aperture 1:40 mm for covering of exhaust fan hole in wall of size 450 mm X450 mm with PVC/woodenbeading fixed on wall including necessary fixing arrangement up to height 11 mtrcomplete all as specified and directed.Note : All safety measures shall be the responsibility of the contractor 346 Supply and fixing in repair building security/ LED street light fitting 36 Watt, 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal, management in multiple optics complete, with IP 65/66 protection complete all as specified and directed. Make: Philips/Bajaj/CG 347 Supply and fix GI pipe 32 mm dia, medium grade for mounting bracket, bent to shape 1.5 meter length and fixing arrangement with two Nos ofclamps set, nut, bolts, washers, andincl taking down old unserviceable GI pipe complete all as specified and directed 348 Supply and fix 1100 Volts grade heavy duty flat weather proof twin core cable of size 4 Sqmm with multistrand aluminium conductor including taking down of old one complete all as directed and specified . Make: Plaza/Polycab/ Finolex 349 Supply and Fixing in repairs of wall focus track light18 wattWW an operating voltage range from 140V-270Vcomplete all as specified and directed.Make : Philips /Luker/ Havells/Bajaj. 350 Supply and Fixing in repairs of channel 2 Mtr lengthforfocus track light complete all as specified and directed. 351 Refixingexisting serviceable LED light fitting fixture any capacity and of any type complete with all accessories internally pre-wired and including connecting up to ceiling rose with twin core twisted flexible copper conductor cable with suitable size after cleaning all dust etc. completeall as specified and as directed . 352 M&L for Sub main wiring with PVC insulated unsheathedFRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 Sqmm drawn through in and incl suitable sizesurface PVC Conduit/ existing concealed conduit and all accessories fixed to wall/floors along with 4 Sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size.Note: (a)2 runs of 4 Sqmm cable along with onerun of 4 Sqmm cable for earth conductor shall be measured as one length.Make:- Havells/ Polycab/ Plaza. 353 S&F in replacementfactory madepowder coated distribution board TPN, 4 way double doorMCBDB includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DBcomplete all as directedMake : Indoasian/ Havells/ Legrand. 354 S&F in replacement factory madepowder coated distribution board SPN 8 way double door,includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DBall as specified and conforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian 355 S & F MCB in repair and replacement ofSPN 240 volts 16 to 40 Amps complete including taking down unserviceable fitting complete all as specified and as directed .Make : Legrand/ L&T/ Indo Asian 356 Supply and fixing in replacement of unserviceableceiling fan 1200mm sweep, energy efficient BLDCISI mark withstar rating 230 Volts AC 50 Hz, single phase including provision of fixing arrangement, nut and bolt andflexible 3 core of size 1.5 sqmm not less than 0.5 m long complete including taking down existing one, writing MES No with synthetic enamel paint all as specified and as directed. Make : Havells/Bajaj/ Orient.Note:-(a)Old Unserviceable ceiling fan shall be deposited to MES store yard. 357 S&F as in repair PVC casing capping medium grade of size 25 mm on wall /roofwith help of screw including serviceable copper /aluminium conductor and all fitting fixture such as Tee, Elbow and lapping,completeall as specified and as directed. Make: Polycab/ Modi/ Presto Plast 358 S&F in repairs 35/36 W( WH) LED recessed type 2x2 luminaire with classic design & glare free soft illumination. housing with white high reflection powder coated (RAL9016) CRCA sheet. Glare free, Opal diffuser for symmetrical light distribution fixed in separate CRCA sheet frame held in with housing by screws for easy maintenance. High efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle of 100° to ensure better uniformity. Powered by an independent Isolated, SELF Output electronic LED driver (SMPS based constant current supply) efficiency of 85% with built-in Surge protection 3Kv. System Lumen Output of 3000 lumens.Make : Philips/ Bajaj/CG/Havells. 359 Excavation in trenches not exceeding 1.5 mtr in width and not exceeding 1.5 mtr in depth for laying of cables up to proper level and laying of pipelines etcinsoft/loose soil, complete all as specified and directed. 360 Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick, complete all as specified and directed. 361 Removing surplus excavated material (soil) not exc 50 meter and depositing where directed at a level not exc 1.5 meter above the starting point, complete all as specified and directed. 362 Material and labour for Spreading ribbed soil in trenches as in cable cushioning all as per IS 1255-1983, complete all as specified and directed.Note :- (i)Excavated approved soil shall be ribbed by using sieve to separate composite particles etc. as per IS and refilling in trenches before laying of cable 8 CM and 15 CM after laying of cable. This is then gently punned down to a depth of 10 cm above the top of upper most cable (ii) For the purpose of measurement only punned thickness shall be considered for payment. 363 Material and labour for well burnt bricks ‘B’ class as mechanicalprotection to under ground cables laying with length of the bricks equal to the width of the trench, complete all as specified and directed. 364 Material and labour for Cutting existing road/PCC/Drain for laying of GI or any type of pipe including necessary earthwork, excavation exc 600mm depth but not exc 1mtr depth, 800 mm wide including making good existing surface with 150 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate, complete all as specified and directed. Note :-The tenderer shall take into consideration for following points while quoting rate for this item andthe unit rate is deemed to be inclusive for :-(i) Earth work and excavation in any type of soil(ii) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick ,complete all as specified and as directed.(iii) Removing excavated material out side MD land.(iv)Laying of any type/any bore of pipe in trenches including taking down existing unserviceable pipe. Supply of pipe shall be measured and paid separately(v)150 mm thickPCC 1:2:4 type B1 using 20mm graded stone aggregate as inroad to make good existing disturbed surfaces. 365 Supply only of GI pipe light grade for cable protection of size 50 mm bore with fittings, complete all as specified and directed. 366 Material and labour in repair for4 core 16 Sqmm XLPEinsulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laid inlaying in trenches/cable ducts, fixed to wall/pole etc complete all as specified and directed.Make :- Havells/Polycab/ RPG Asian 367 Material and labour in repair for 3 ½ core 25 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laid in trenches/cable ducts, fixed to wall/pole etc, complete all as specified and directed. Make : Havells, Polycab, RPG Asian 368 Disconnecting of burnt/ damaged cables from panels/ junction boxes etc, cutting out the burnt out ends, making new end joints by supply and fixing new aluminium lugs/ insulation tape etc and reconnecting using new nuts/ bolts/ washer etc and restoring three phase and neutral in the junction box, complete all as specified and as directed for thecable sizefrom 16Sqmmto 25 Sqmm 3.5 core of underground LT armoured cables.Note :- Earth work required for extending the incoming/ outgoing cable in junction box/ panel board etc shall deemed to be included in the unit rate quoted. 369 Supply, installation, testing and commissioning LTFeeder pillar box double door CPRI Testedof Size 400X250X350mmsuitable for 3 phase 415 Volts of suitable size out door made out 3.15mm thick CRCA sheet of outdoor of panel with angle iron frame of size 32x32x5mm cubical type complete with aluminium bus bar 100 Amp and including PCC foundation as per site requairment to accomodated to the following.INCOMING(a)MCB TPN32 Amp 10 KA - 01 No. (b)LEDindicating lampR-Y-B - 03 Nos. OUTGOING(a) Weather Proof panelPlug and shocket angled type IP 67three Phase 3P+N +E, 20 Amp - 01 No(b) Weather Proof plug and shocket angled type IP 67 Single Phase 2P+E , 20 Amp- 01 No.(a)MCB TPN20 Amp 10 KA - 01 No. (a)MCB SPN20 Amp 10 KA - 01 No. 370 Supply and Fixin repair and replacement ofsurface mounted Square/Roundfor LED 18W Watt downlights made of extruded Aluminium housing and high power LED light source withDriver clear diffuser with separate electronic driver with complete accessories all as specified and directed .Make : Philips/ Bajaj/ CG/Havells. 371 M&L for cutting of hole through stone wall with the help of Core cutting machineincluding providing, fixing and removing shoring,cleaning,internal plastering and removing surplus hard core,rubbish not exceeding 50 mtrs including fixing of exhaust fan of size 250-450 mm all as specified and as directed. 372 Supply and fixingExhaust fan250 mm sweep 230/ 240 volt AC single phase PVC body1400 RPM including necessary nut, bolts / screws including taking down existing one writing MES No with synthetic enamel paint all specified and directed.Make : Havells/Bajaj/ Orient/USHA.Note:-Old Unserviceable Exhaust fan shall be deposited to MES store yard. 373 S&F as in repair energy efficient wallmounted LED luminaire5 WX2wooden finish(WW), The luminaire shall have a CRI >80, Color temperature 6500K, THD <10% and PF >0.95,SDCM<5, IP20, IK02. Operating Temperature: -10 TO + 45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-55 HZ supply single phase including connecting with PVC insulated three core flexible copper conductor of suitable size from ceiling rose to fitting and fixing to ceiling complete all as directed. Make : Philips /Luker/ Havells/Bajaj. 374 Supply and fix 1100 Volts grade heavy duty flat weather proof twin core cable of size 6 Sqmm with multistrand aluminium conductor including taking down of old one complete all as directed and specified . Make: Plaza/Polycab/ Finolex 375 Supply & Fixing in replacement of electronic LED driver 18/20 W suitable for round ceiling light indoor fitting of make Philips/ crompton/ Bajaj, complete all as specified and directed . 376 S & Fin replacement 9 watt LED lamp, complete all as specified and directed. Make : Philips/ Bajaj/ Crompton 377 M & L for Point wiring with PVC insulated FRLS 1.5 sq mm multi stranded copper conductor cable 1100 Volts grade drawn into and including concealedrigid non mettalic PVC conduit/casing caping medium grade not less than 19/20 mm ( ISI marked ) with all fitting and fixing accessories including sunk in pressed steel chromium plated terminal boxes, concealed in wall/surface/roofs/floor/ceiling etc as per site requirement and making & maching the existing surface ) white bakelite sheet cover for mounting switches, Sockets, Fan regulators etc or modular cover plate with frame including sunken boxes suitableto fix modular cover plate with frame , concealed in wall or 1.5 sq mm multi stranded copper conductor cable as continuous earth wire drawn with wiring and connected to common earth dolly complete all as specified and directed for the following :- Make of wire: Polycab/Plaza/HavellsNote:Blanking plate,Modular cover plate ,Switches, sockets outlets, Light fittngs, fans, bells & regulators shall be measured and paid for separetely). 378 All as per item No. 377 here in before but for one light point/fan/bell point controlled by one wayswitch. 379 All as per item No. 377here in before but for one light point controlled by twowayswitch. 380 All as per item No. 377here in before but for one bell point controlled by one bell push. 381 All as per item No. 377 here in before but for one 3 pin socket out 5 Ampon the same board 382 All as per item No. 377 here in before but for one switch socket outlet 3 pin 5 Amps on independent board 383 All as per Sl No 377 above but Wiring with 2.5 Sqmm copper multistranded unsheathed cable and 2.5 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently etc complete all as specified and directed. 384 All as per Sl No 377 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently etc complete all as specified and directed. 385 Supply and Fixmodular switch1 way 6 Amp.1 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor/Indoasian 386 Supply and Fixmodular switch2 way 6 Amp.1 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor /Indoasian 387 Supply and Fixmodular switchbell push .1 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor /Indoasian 388 Supply and Fixmodular Socket, 6A - 2/3 pin combined 2 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor/Indoasian 389 Supply and Fixmodular switch1 way 16 Amp.1 module, complete all as specified and directed. Make :Legrand/ Crabtree/ Anchor /Indoasian 390 Supply and Fix modular Socket, 16A - 2/3 pin combined 2 module, complete all as specified and directed. Make : Legrand/ Crabtree/ Anchor/Indoasian 391 Supply and fix White cover plate with frame,2/3 module 392 Supply and fix White cover plate with frame,4 module 393 Supply and fix White cover plate with frame,8 module 394 Supply and fix White cover plate with frame,6 module 395 Supply and fix White cover plate with frame,12 module 396 S & F Modular fan regulator 120W, 2 Module for ceiling fan complete all as specified and directedMake : Legrand/ Crabtree/ Anchor 397 Supply and Fixingof 4 feet surface mounted emergency battern type luminaire , lumen output of 2000 lumens, high efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle not less than 120° to ensure better uniformity with an operating voltage range from 140V-270V. The luminaire shall have a white extrusion housing with a poly carbonate diffuser to provide uniform light and sleek design with width not more than 22 mm.complete all as specified and directed.Make : Philips/ Bajaj /CG/Havells. 398 M&L for Sub main wiring with PVC insulated unsheathedFRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 Sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with 4 Sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size.Note: (a)2 runs of 4 Sqmm cable along with onerun of 4 Sqmm cable for earth conductor shall be measured as one length.Make:- Havells/ Polycab/ Plaza. 399 S&F in replacement factory madepowder coated distribution board SPN 6 way double door,includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DBall as specified and conforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian 400 S & F in repair and replacement of MCB single pole 240 volts 6 to 40 Amps complete including taking down unserviceable fitting complete all as specified and as directed .Make : Legrand/ L&T/ Indo Asian 401 Supply and Fixing in repairs of 2 feet surface mounted batten type luminaire , lumen output of 1000 lumens, high efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle not less than 120° to ensure better uniformity with an operating voltage range from 140V-270V. The luminaire shall have a white extrusion housing with a poly carbonate diffuser to provide uniform light and sleek design with width not more than 22 mm. The luminaire shall have a CRI >80, Color temperature 6500K, THD <10% and PF >0.95,SDCM<5, IP20, IK02, Operating Temperature: -10 TO + 45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-55 HZ. The luminaire shall have flicker content<5% and shall have high and low cut off with auto restart feature.Driver Safety requirement stds: IS 15885-2-13. The luminaire shall be EMI/ EMC compliant and shall have a internal surge protection of 4 KV. The luminaire shall have Class-1 Electrical insulation, Class-B serviceability .The luminaire and driver shall be BIS approved, complete all as specified and directed.Make : Philips/ Bajaj / CG/Havells. 402 Supply and Fixing in repairs of LED Outdoor under water light 12 X3 , IP68, suitable for swimming pools/façade etc. RGBincluding control panel and necessary cable from control panel to light approx 5 mtrcomplete all as specified and directed. Make : cat No : SZLFUM012x3W-RGB of Shakti /Philips/ Bajaj/ CG/Havells 403 S&F in replacement factory madepowder coated distribution board SPN 4 way double door,includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DBall as specified and conforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian 404 S & F MCB in repair and replacement ofSPN 240 volts 63 Amps complete including taking down unserviceable fitting complete all as specified and as directed .Make : Legrand/ L&T/ Indo Asian 405 S&F in repairs 35/36 W (WW) LED Surface type2x2 luminaire with classic design & glare free soft illumination. housing with white high reflection powder coated (RAL9016) CRCA sheet. Glare free, Opal diffuser for symmetrical light distribution fixed in separate CRCA sheet frame held in with housing by screws for easy maintenance. High efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle of 100° to ensure better uniformity. Powered by an independent Isolated, SELF Output electronic LED driver (SMPS based constant current supply) efficiency of 85% with built-in Surge protection 3Kv. System Lumen Output of 3000 lumens.Make : Philips/ Bajaj/CG/Havells. 406 Material and labour forBoring of holes under road, pavement hard standing by trenchless technology using ultra sound technique and necessary machine including supply of HDPE pipes upto 50 mm dia suitable for 0.4 Mpa working pressure, complete all as specified and directed. 407 Material and labour in repair for 3 ½ core 35 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed layid in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells, Polycab, RPG Asian 408 Material and labour in repair formaking straight through joint with suitablejointing kit consisting of water proof adhesivesfor UG cable of size 3.50 core 25 Sqmm to 35 Sqmm, complete all as specified and directed. 409 Disconnecting of burnt/ damaged cables from panels/ junction boxes etc, cutting out the burnt out ends, making new end joints by supply and fixing new aluminium lugs/ insulation tape etc and reconnecting using new nuts/ bolts/ washer etc and restoring three phase and neutral in the junction box, complete all as specified and as directed for thecable sizefrom 25Sqmmto 35 Sqmm 3.5 core of underground LT armoured cables.Note :- Earth work required for extending the incoming/ outgoing cable in junction box/ panel board etc shall deemed to be included in the unit rate quoted. 410 Supply, installation, testing and commissioning indoor panel box CPRI Testedof Size 800x600X450 mmsuitable for 3 phase 415 Volts IP 54 of suitable size out door made out 2.00 mm thick CRCA sheet of indoor panel with angle iron frame of suitable sizecubical type with one side cable Alleycomplete with suitable size bus bar and including wall mounting clamp as per site requirement to accomodated to the following.INCOMING(a)MCCB 4 pole 250 Amp 25 KA - 01 No. (b)LEDindicating lampR-Y-B - 03 Nos.(c)Digital Ammeter with selecter switch andsuitable capacity of CTs- 01 No (d) Digital Voltmeterwithselecter switch - 01 No(d) Space for provn of 3 Phase KWH Main meter-01 No OUTGOING(a)MCCB 4 pole 100 Amp 16 KA - 03 Nos. (b)MCCB 4 pole 63 Amp 16 KA - 01 No. 411 Supply, installation, testing & commissioning of maintenance free chemicalearthing system comprising of 17mm dia copper bondedrod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducingliquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 A by any NABL accredited lab. The above mentioned rod shall be installed in 4-6 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation including taking down existing one, complete all as specified and directed..Make : Model HTSP 317 of safeTrode or equivalent in Snaga/ Cubes 6 Global 412 The quoted rate shall also deemed to be included the following :- (i)Prior toinstallation of maintenance free chemicalearthing, soil resistivity test to be carried out at the location where earthingwork to be donein presence of Engr-in- Charge/JE (E/M),user and the report has tosubmitto Garrison Engineer with recommendation of manufacturer, if required additional interconnection ofearthing (not more than 08 number of earthing) to achive earth result less then 1 Ohms. The arrangement done for soil resistivity testingandsubmission of report with recommendationdeemed to be included in the quoted rate. 413 (ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors. 414 (iii) Rateofearth energizer compound of 25 Kg of 02 bags and earthresistance reducingliquid 10 litre per cane for each pit deemed to be included in the quoted rate. 415 (iv)Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor along with the sample approval 416 (v) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH value should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete. 417 (vi) Copper strip of size 20 x 3 mm shallbe fixed on proper post insulator at the instrument end (copper strip upto 7.5 RM shall be considered in unit quoted rate and extra will be measured and paid separately). 418 (vii)Testing of earth shall be carriedout in presence ofdepartmental and user representativeand report shall be submitted to Garrison Engineer duly signed by all concerned. 419 (viii)Earth resistance tester will be provided by the contractor.Tester should be calibrated from authorised company/ lab. 420 (ix)Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintained duly signed by all concerned.After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained. 421 (x) The contractor shall give a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion. 422 (xi) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including soft/ disintegrated or hard rock. 423 (xii) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is maintained. 424 (xiii) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing for each earthing shall be retained from payment due to the contractor from final bill for the guarantee period. 425 (xiv) The electrode shallcarry manufacturers name . 426 (xv) The connection clamp shall be permanentlly welded to the copper boundedrodto avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination. 427 (xvi) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm. 428 (xvii)Earth work such as auguring andmaking good the surrounding area shall carried out in any type of soil. 429 (xviii)The contractor shall submit CPRI India certified document for copper bounded rod to ensure genuineness of material. 430 (xix) Sign boardof mild steel sheet 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxideZinc chrome primer showing result of earthing shall be fixed near the earth pit after completion as directed by engr -in- charge. 431 Material and labour for Earth pit cover madeof heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 7.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mm for each electrode pit complete including taking down old one complete all as specified and directed.Make : Model SEPC 250 of SAFE TRODE or equivalent in Snaga/ Cubes 6 Global 432 S&F in repair copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc including taking down existing old unserviceable copper strip etc, complete all as specified anddirected. Note : - All Joints should be joined by Exothermic Welding or Brazing. 433 Supply, installation, testing and commissioning LTFeeder pillar box CPRI Testedof Size 800x600X450 mmsuitable for 3 phase 415 Volts of suitable size out door made out 3.15mm thick CRCA sheet of outdoor of panel with angle iron frame of size 50x50x6mm cubical type complete with aluminium bus bar 600 Amp and including PCC foundation as per site requairment to accomodated to the following.INCOMING(a)MCCB 4 pole 315 Amp 36 KA - 01 No. (b)LEDindicating lampR-Y-B - 03 Nos.(c)Multifunction Meter (V,I,PF) with suitable capacity of CTs- 01 NoOUTGOING(a)Through Bus Bar 434 Note :- An amount of Rs 2,14,139.00 on account of credit schedule for schedule A part II shall be deducted from the total amount of BOQ to arrive at the contract sum.
BRR : 6764634
Tender For Additional / Alternator To Drain And Sewage Line Of P-5 (Nest), P-104 (S&T) And P-11 And P-21 (Chinar), Provn Of Footpath With Strom Drain For OrS Married Qtrs (Mdf), And Special Repair To Ante Room, Bar Room And Dinig Hall Of Bldg No P-7 Of Mg & G Area Officers Mess Under Ge (W) Colaba.; 1 Excavation in trenches n exc 1.5 m width n exc 1.5 mdepth in any type of soiland getting out all as specified and directed. 2 All as per item No 1 above but exc 1.5 m depth all as specified & directed 3 Demolition and breaking up drain pipes of dia 150 mm (Salt glazed stone ware, AC or Reinforced concrete) set in cement mortar all as specified and directed. 4 Demolition and breaking up drain pipes of dia 200 mm (Salt glazed stone ware, AC or Reinforced concrete) set in cement mortar all as specified and directed. 5 Demolition and breaking up drain pipes of dia 300 mm (Salt glazed ware, AC or Reinforced concrete) set in cement mortar all as specified and directed. 6 S&F Reinforced concrete pipes, class NP3, 150 mm dia laid and jointed including complete demolition with collars all as specifed and directed. 7 S&F Reinforced concrete pipes, class NP3, 200 mm dia laid and jointed including complete demolition with collars all as specifed and directed. 8 S&F Reinforced concrete pipes, class NP3, 300 mm dialaid and jointed including complete demolition with collars all as specifed and directed. 9 M&L PCC in 1:3:6 type C-2, (using 40 mm graded crushed stone aggregate concrete bed to 150mm dia drain pipes including packing under and completely surrounding pipes with concrete after they are laid and tested all as specified and directed by Engineer-in-Charge. 10 M&L PCC in 1:3:6 type C-2, (using 40 mm graded crushed stone aggregate concrete bed to 200mm dia drain pipes including packing under and completely surrounding pipes with concrete after they are laid and tested all as specified and directed by Engineer-in-Charge. 11 M&L PCC in 1:3:6 type C-2, (using 40 mm graded crushed stone aggregate concrete bed to 300mm dia drain pipes including packing under and completely surrounding pipes with concrete after they are laid and tested all as specified and directed by Engineer-in-Charge. 12 Cutting into existing manhole for connecting new drain for bore of pipe 200mm, making good to pipe and rendering, cutting out existing benching and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1, smooth finished and reforming benching as required all as specified and directed 13 Cutting into existing manhole for connecting new drain for bore of pipe 300mm, making good to pipe and rendering, cutting out existing benching and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1, smooth finished and reforming benching all as specified and directed. 14 Returning, filling in including spreading leveling watering and well ramming in layers n. exc 25 cm in soft/loose soil all as specified and directed 15 Removing excavated soil to a distance n. exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point all as specified and directed 16 Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone work and precast concrete articles all as specified and directed 17 M&L in repairs for brick work with sub class B brick straight or curved on plan exc 6 metre mean radius with old size bricks built in CM 1:4 for cracked wall of man holes, septic tank, soak pits etc including demolition all as specified and directed. 18 M&Lfor Except bricks with old sub class B bricks (obtained from demolition) straight curved on plan exc 6 metre mean radius with old size bricks built in CM 1:4 for cracked wall of manholes, septic tank, soak pits all as specified and directed. 19 M&L in repairs PCC 1:2:4 grade Solid block of size 390x150x200 /600x300x300 mm, built in cement mortar 1:6 including demolitionall as speified & directed. 20 Taking down cement plaster on brick or stone walls, etc. including raking out joints,hacking for key, scrubbing down with water all as specified and directed by Engineer-in-Charge. 21 M&L plastering 15mm thick in cement mortar 1:4 on brick or concrete masonry walls, finished surfaces even and fair without using extra cement by using 2 % water proofing compound all as specified and directed.Note- (i) WPC shall be measured and paid for separately as Supply only. 22 Supply only integral water proofing compound.Make - Fosroc / Sica / Dr Fixit 23 Demolition of Cement Concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) all as specified and directed. 24 M&L for cement concrete 1:2:4 type B0,(using 12.5 mm graded crushed stone aggregate) as in coping/cills using necessary form work weathering, slightly rounded or chamfered angles and throating all as specified and directed. 25 M&L in repairs for PCC (1:3:6), type C2 (using 40 mm graded crushed stone aggregate ) in foundation filling and mass concrete for bottom of manhole including demolition complete all as specified and directed. 26 Demolition of Concrete (reinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed. 27 M&L in repairs for RCC (1:2:4), type B1 (using 20 mm graded crushed stone aggregate) in Precast cement concrete cover slab in walls or retaining walls, any thickness, size or shape including plasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases) for manholeand similar article with plain face, set in cement mortar 1:4 including demolitionall as specified and directed. 28 M&L in repairs for RCC (1:2:4), type B1 (using 20 mm graded crushed stone stone aggregate) Precast cement concrete cover slab for man hole and similar article with plain face, set in cement mortar 1:4 including demolitionall as specified and directed. 29 Use & waste formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter all as specified and directed 30 S&F in repairs factory made precast RCC drain cover of size 1000mm x 500mmx100 mm thick, fixed to drain in CM 1:4 all as specified and directed.Note: No extra payment is to be given to contractor for reinforcement and formwork) 31 S&F TMT bars 8 mm dia and over cut to length bent to shape required including cranking, binding with MS wire (annealed) not less than 0.9 mm dia all as specified and as directed. 32 M&L in repairs for 75 mm dia PVC (SWR) multi floor trap with grating including jointing with solvent cement all as specified and directed 33 S&F in repairs PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement/adhesive including dismantling of existing gully trap with chamber and making new chamber with PCC 1:2:4 type B1covered with RCC cover all as specified and directed. 34 S&F in repairs 75 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints, sealed with adhesive suitable for PVC pipes andfixed to walls all as specified and directed. Note : work shall be carried out upto any height including necessary scafolding. 35 S&F in repairs 110 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints, sealed with adhesive suitable for PVC pipes andfixed to walls all as specified and directed. Note : Work shall be carried out upto any height including necessary scafolding. 36 S&F 75mm dia PVC (SWR) bends with access doors any radius all as specified and directed. 37 S&F 110 mm dia PVC (SWR) bends with access doors any radius all as specified and directed 38 S&F 75 mm dia PVC (SWR) junction single, (single T) equal or uequal provided with access door all as specified and directed. 39 S&F 110 mm dia PVC (SWR) junction single, (single T) equal or uequal provided with access door all as specified and directed. Note : upto 5th storey of bldg. 40 S&F 75mm dia PVC (SWR) branch piece,single (single Y) equal or unequal all as specified and directed. 41 S&F110 mm dia PVC (SWR) branch piece, single (single Y) equal or unequal all as specified and directed. 42 S&F 75 mm dia PVC (SWR) branch piece, single (double Y) equal or unequal all as specified and directed. 43 S&F 110mm dia PVC (SWR) branch piece, single (double Y) equal or unequal all as specified and directed. 44 S&F 75 mm dia PVC (SWR) vent cowl all as specified and directed 45 S&F 110mm dia PVC (SWR) vent cowl all as specified and directed 46 S&F cast iron manhole covers alongwith frame grade A-35 T/A-350 KN, machined each exc 5 Kg by weight all as specified and directed. 47 Dismantling and refixing after preparation of sub base, 25mm thick coloured chequred cement concrete tiles with gray cement and colour pigment of size 300mm x 300mm/200x200mm set, jointed and pointed with neat cement slurry as in floor including 20mm thick screed bed in CM 1:4 all as specified and directed. 48 Dismantiling and refixing after preparation of sub base, 60mm/80 mm thick coloured interlockingtiles with gray cement and colour pigmentset, jointed and pointed with neat cement slurry with as in floor including 20mm thick cement mortar screed bed in CM 1:4 and complete all as specified and directed. 49 S&Fframed work such as grills, gratings with ends of bars shouldered and/or riveted or forged into spikes,framed guard bars, barred iron doors, ladders, windows, balcony in ground floor, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to FE 290 Gde -E-165 all as specified and directed. 50 M&L for preparation of new or previously untreated surfaces and applying two coats of synthetic enamel paint over a coat of primer red oxide, zinc chrome all as specified and directed. 51 Demolition of stone slabs and tiles of any description or thickness in floors aprons etc laid, bedded and pointed in any mortar and removal of rubbish off the site all as specified and directed 52 M&L rubber moulded glossy finished 60 mm thickness precast concrete interlocking paver block of any shape and size confirming to IS 15658 -2006 of, M-35 Grade with grey cement and pigment laid over sand cushningincluding compaction of paver blocks using surface vibrator including 25 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.Make - Vitco or equivalent 53 M&L Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed andpointed in neat cement slurry in floors all as specified and directed. 54 M&L PCC type D-2, 1:4:8 (using 40 mm graded crushed stone aggregate) in foundations, filling and mass concrete all as specified and directed by Engineer-in-Charge. 55 M&L for crushed stone sand filling under precast interlocking paver blocks of any thicknessand all other similar works all as specified and directed. 56 S&F 900mm x 600mm FRP manhole cover of 20 Ton loading capacity with frame over manhole coping concrete all as specified and directed. 57 Dismantling wrought iron or mild steel work of any description not otherwise provided forall as specified and directed. 58 M&L for preparing old damaged road surfaces and repairing by using PCC 1:2:4 type B-2, (using 40mm graded crushed stone aggregate) all as specified and directed. 59 (a) Cleaning and desilting of manholes depth not exc 1.50 meter by pumping out/removing liquid waste/sewage and plugging the ends sewer pipes or diverting the flow into drains if necessary, removing silt, sludge etc,sprinking bleaching powder on the silt to avoid bad smellincluding all precautionary and safety measures, such as safety belts, lighting arrangements face mask etc and removing the same (silt, sludge & other waste material) inleak proof trucks covered with tarpoline to outside of MD land allas per existing rules and regulations of civil authorities and cleaning the man holes with fresh water all as specified and directed by Engr-in-Charge. (b) If required getting a honey sucker and cleaning the heavily congested sewage line. (c) JCB and other machinery required on special basis would be called on requirement basis. 60 Cleaning and desilting of manholes depth exc 1.50 m but not exc 3.00 mby pumping out/removing liquid waste/sewage and plugging the ends sewer pipes or diverting the flow into drains if necessary, removing silt, sludge etc,sprinkling bleaching powder on the silt to avoid bad smellincluding all precautionary and safety measures, such as safety belts, lighting arrangements face mask, etc. and removing the same (silt, sludge & other waste material) inleak proof trucks covered with tarpoline to outside MD land all as per existing rules & regulations of civil authorities and cleaning the manholes with fresh water etc complete all as specified and directed by Engr-in-Charge. 61 Empting choked up sewage lines and manholes exc 3.00 mtr depth by providing sewage suction vehicle of capacity 5000 ltrs (BMC Pattern) including necessary other arrangments such as sweepers to clean up the site after work and desposing the same at places earmarkd outside MOD land upto 25 KM lead and lift all as specified and directed.Note :- (a)All precautions to be taken by all workers while working in foul condition. Contractor shall take all necessary actions. (b)After cleaning vehicle will be contractors property. (c) Contractors accredated representative shall be available during the cleaning. (d) Complete process shall be completed in all respects within a day. 62 M&L PCC 1:4:8, type D2(using 40mm graded crushed stone aggregate) as in surface channels and drains all as specified and directed. 63 M&L PCC 1:2:4, type B2(using 40mm graded crushed stone aggregate) as in surface channels and drains all as specified and directed. 64 M&L plastering 10mm thick on fair faces of brick work or concrete surfaces in CM (1:4) surfaces shall be finished even and smooth (without using extra lime or cement) all as specified and directed. 65 M&L RCC type B1 1:2:4 (using 20mm graded crushed stone aggregate) slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and inshelves and the like all as specified and directed. 66 M&L mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and directed. 67 S&F joist, channel, angle or tee sections, or MS Flats fixed independantly without connecting plates, etc. Fe 410-W (Gde-E- 250) quality- A (cut to ordinary lengths i.e within 20mm of length indicated) as in frame work for Galvalume / CGI chajjas all as specified and directed. 68 M&L coloured digital ultra strong / heavy duty outdoor anti skid vitrified tiles 15 mm thick (Square / Rectangular) polished, area of each tile exc 0.09 Sqm and not exc 0.36 sqm, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the shade of tiles laid over and including 20 mm thick rendering in CM (1:4)for fixing oftiles all as specified and directed. 69 M&L20mm thick Granite (of any type) machine cut in, wall lining, steps, jambs, pillars, window cills, skirting/dado laid over cement screed and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting and polishing and including rendering 10 mm thick on fair faces of brick work or concrete surfaces in CM (1:4) all all as specified and directed. 70 M&L PCC 1:2:4 type B0 (using 12.5 mm graded crushed stone aggregate) as in coping, bed concrete and all other similar works including necessary formwork all as specified and as directed. 71 Dismantling plain or corrugatedsteel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings including scafoldings of any height all as specified and directed. 72 S&F Pre-painted galvalume aluminium zinc coating GI based trapezoidal/mangalore tile profile roofing sheets, chajjas,0.50 mm thick of any colour/length having tensile strength of 550 MPA as in roof coverings having effective & overall width 1015 mm & 1072 mm respectively, profile height 28.5 mm and centre to centre distance between ribs 203 mm fixed with self tapping screws as directed by manufactureron wooden/steel membersincluding scafoldings of any height of the bldg all as specified and directed. 73 S&F Pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 MPA as in roof coverings /claddings to wall, fixed with self tapping screws including scafoldings of any height all as specified and directed. 74 S&F structural steel work in tubular/square tube trusses including special shaped washer, gusset/bearing plate using ERW or induction butt welded tubes conforming to I.S.1161-1979 grade St.-240 all as specified and directed. 75 M&L RCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) as in columns, foundations, beams, slabs, parapet, staircase including demolition all as specified and as directed by Engr-in-Charge. 76 Use & waste special water tight centering and shuttering including bolting, strutting, propping etc. so as to withstand a pressure of 0.1 Mpa including removal of form work of all locations including beams, columns, slabs, walls, foundations, footings, landings, stairs, balconies all as specified and as directed by Engr-in-Charge. 77 All as per item No 66 here in before but 5mm dia and over upto and including 10mmdia in stirrups, spacers and binders 78 Rebuilding the section of damaged RCC elements to its original size or as per consultants recommendations in thicknesses of 40-100 mm by providing and casting with micro-concrete of grade M-40 and above including providing and fixing of water tight foam faced finish shuttering of minimun 18 mm thick with supporting framework, all lead lift, mixing, placing, deshuttering, levelling the surface by grinding off cementitious slurry or construction joint differences if any to satisfaction of engg. incharge, curing etc. complete.(Rate including- cube test to be conducted for every 5 M.T. workdone.6 nos of sample required per test). Ensure the quality of water by testing water as per IS 456 and document the same. Ensure temperature at time of mixing should be between 25 to 40 degree celcius by electronic temperature gauge 79 Taking down Chowkhats and shutters of windows/ventilators with wire mesh / glassand MS grills of any size including all fittings and fixtures all as specified and directed. 80 Providing and fixing factory made uPVC rigid coloured three track sliding window, made of extruded profiles. Profiles of frames and sash will be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arragement for fixing hardware, EPDM gasket, 1.2+- 0.2 mm thick galvanized steel profile to be inserted in required profile,frame will be fixed to the wall with 8mmx100-mm long fasteners all as specified and directed. 81 Providing and fixing Powder coated aluminium (minimum thickness of powdercoating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making, provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-Charge.Note : (i) Glass panes will be measured & paid separately . (ii) The quoted rate shall be inclusive of cost of rubber beading and glazing clips, hionges, handle. However it will be not be weighed and not paid separately.(iii) All other minor details including cost of locking arrangement shall be included in the quoted rate. 82 S&F sheet glass, ordinary quality, 6.3 mm thick, plain or frosted on one side and glazed with oil putty or fixed with rubber beading in square exc 0.5 Sqm in each pane or as required all as specified and directed. 83 S&FAluminium deco grill Cat No DG-916, 7.5 mm thick, cut to required size/shape and fixed in position with aluminium beading all as specified and directed by Engineer-in-Charge. 84 S&F in repair 12mm thick, toughened glass for door shutters, partitions in bathroom or other places, shelves, table top etc and in similar work with and including fitting and fixtures such as glass handles stailess steel studs, fittings for door pivots all as specified and directed. 85 S&F Sun control film, 50 micron non reflective type, sticked to glass as per manufacturers instructions all as specified and directed. 86 S&F in repair SS 202 Stain finish Handle D type, 25mm dia 600mm longfor glass shutter all as specified and directed 87 S&F in repairs bottom/top patch fitting for pivot all as specified and directed 88 S&F in repairs bottom lock patch fitting all as specified and directed 89 S&F aluminium (Die cast) body, door closer,hydraulically regulated, designation No. 3, unversal type, suitable for door shutters of 851 to 1000mm in width and of weight between 61 to 80 kg all as specifed & directed. 90 S&F in repairs SS 304 Grade metal letters of height 200mm with PU paint to match the logo colours, mirror polish finish, anti rust and including necesssary arrangements to fixing in walls, using scaffolding at any height all as specified and directed. 91 S&F In repairs 3 mm thick panel of any type, pattern and shape Aluminium Composite Panel (ACP), aluminium thickness of0.5mm, Front side finish of aluminum roll coated with Plain / coloured / wooden texture PE / PVDF, Core material ofNon-toxic polyethylene, Macromolecular lamination film, Rear side of Aluminum coated with primer and including frame work using of Fasteners, including concealed screws, nuts, bolts and other items requiredfor connecting aluminium to aluminium / steel / wooden / ply board, Blind rivets all fixing anchors, brackets and similar attachments used in the erections, shall be of aluminium, non-magnetic stainless steel, zinc coated steel, for fixing in both internal / external wall cladding complete weather proofing sealant of a polyurethane elastic joint / structural silicone sealant / pre-formed gasketsto the Horizontal & Vertical Joints in the Aluminium cladding / facade as per manufacturers instructions all as specified and directed.Note : 1. The unit rate quoted is deemed to be inclusive of all necessary fixing acceserries mentioned in the description of work and scaffolding works at any height for installation.2. For payment purpose panels areas will be measured on one side only. 92 M&L 75 mm PCC 1:3:6 type C-2using 40 mm graded stone aggregate as in plinth protection, flooring/subbase including necessaryshuttering all as specified and directed. 93 M&L broken stone or bouldershardcore of gauge n exc. 63 mm,deposited, spread and levelled inlayers n exc. 15 cm thick, watered and rammed to a true surface using power roller all a specified and directed by Engr-in-charge. 94 M&L Earth filling in floors, including spreading and leveling in layers, well ramming including watering as required all as specified and directed. 95 Dismantling of ceiling board (Plup insulation or insulation etc) or insulation board any thickness including cover fillet/grid all as specified and directed. 96 S&F in repairs POP false ceiling consisting of frame work made with 50 mm Sq MS tube of 18 G thickness as main runner at 600 mm c/c both ways suspended/supported with MS flats 25x4 from existing RCC slab including providing and fixing expended metal of size 5.25 mm x 1.25 mm thickness welded to main runnersand applying POP (calcium silicate semihydrate variety) to the expended metal of thickness not less than 10 mm finished smooth to line and level including necessary supports scaffolding etc as required and also including applying a coat of red oxide zinc chrome primerover the MS frame work andtwo coats of OBD apply oncelling and suspended portion all as specified and directed 97 Extra over above items no. 96for any sunk or raised moulding all as specified and directed. 98 M&L 8/10 mm thick PVC ceiling or wall panelling (any colour) with aluminium frame work for receiving ceiling board / wall panelling including all necessary accessories for fixing at various levels all as specified and directed. 99 M&L 15-25 mm average thick Ready Mix Plaster in multy layermixed withliquid water proofing compound on other than fair faces of brick wall or concrete surfaces,including use of scaffolding all as specified and directed.Note :-Liquid water proofing compound will be measured and paid seperately as supply only. 100 M&L for 12 mm thick ready mix plaster in single layer on brick wall or concrete surfaces including making groove of appropriate size, on other than fair faces of concrete/brick surfaces (internal surface) and finished surfaces even & smooth without using extra cement all as specified and as directed. 101 Supply only liquid water proofing compound. 102 M&L for preparing new plastered surfaces of externalwalls / ceilings by scrapping / rubbing and applying two coats of weather proof acrylic exterior paint (100% Acrylic)over a coat of primer including use of scaffoldings all as specified and directed 103 M&L for preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper over a coat of birla putty (avg 2 mm thick) all as specified and directed. 104 M&L for complete removal oldplastered surfaces of walls and applying two coats of Plastic emulsion paint over a coat of birla putty (avg 2 mm thick)all as specified and directed. 105 M&L for two coats of smooth interior acrylic emulsion with Texture finish having VOC less than 50 grams per ltr complying LEEDS criteria @1 ltrs (unndiluted) /10 sq mtrs diluted with water in 2:1 ratio applied over priming coat with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI. Allow 6-8 hrs to dry the surface in both the coats of paint as per manufacturer instructions all as specified and directed. 106 S&F in repairs curtain rod (decorative type) Stainless steel 25 mm dia painted with powder coating of any colour on S.S. as approved by GE all as specified and directed. 107 S&F curtain brackets decorative type (antique), for receiving single/double curtain rod,fixing for 20 mm rod all as specified and directed. 108 Complete removal of old existingpolish of doors/windows by using blow lamp or by grinder and applying French polishing on surfaces of any description, width or girth including cleaning and preparing the surface including a coat of wood filler one or more coats of best quality all as specified and directed 109 M&L Granite (of any type and colour) 20 mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing laid in floors/Jambs/WHB conters and all other similar works in approved design laid over 20 mm thick screed bedin CM 1:4 all as specified and directed. 110 M&L in repairs coloured double charged polished glazed vitrified tiles 10 mm thick (Square/rectangular) polished, area of each tile exc 0.36 sqm but not exc 0.64 sqmin floors,set and jointed in neat cement slurry and pointed in white or coloured cement to match the shades of the tiles including dismantlingall as specified and directed. 111 M&Lcoloured double charged digital glazed vitrified tiles 10 mm thick (Square/rectangular) polished area of each tile exceeding 0.36 sqm but not exec 0.64 sqmin vertical surfaces such as skirting & dados,set and jointed in neat cement slurry and pointed in white or coloured cement to matchincluding dismantlingall as specified and directed. 112 M&Lin repairs for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc. including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of floor or the side of waist slab with suitable arrangemet for Stainless Steel grade 304 decorative designer railings, staircase, covers, sitting place, shed etc.(design and pattern as approved) made out of completeall as directed by Engineer-in-Charge 113 Taking down rainwater pipes (anysize or pattern), including all fittings, heads, shoes, bends, swan-necks, etc.,removal to Store(measured overall as fixed along thecentre line over fittings andaccessories) all as specified and directed. 114 S&F rain water gutter in half round shape 110mm dia PVC ( SWR) grade pipes single socketed in any length with integral outlet of 110 mm dia all as specified and directed. 115 S&FPVC (SWR), 110mm bore, Doublesocketed in any length with rubber ring joints, fixed to walls with MS clamps made out of flat iron of size 25mm x 3mmincluding nuts bolts at any location, any floor including necessary scaffolding all as specified and directed. 116 S&f 110mm dia PVC (SWR) bends /elbow any radiusincluding GI clamps of approved shape and size approved by GE at any height, any location, any floor including necessary scaffolding all as specified and as directed. 117 Taking down carefully copper/aluminum point wiring light/fan/sockets out let/power point complete (fittings such as switches, sockets, ceiling rose, pendent holders, light fittings etc. are to be measured separately) and/or drawing out from existing conduit/batten and making good disturbed surface of walls/floors/ceiling, complete all as specified. 118 M&L for Point wiring with 1.50 Sqmm single core PVC insulated, unsheathed cable FRLSH, 1100 volts grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, PVC conduit not less than 20 mm dia with accessories, concealed on wall/ceilingand incuding provision of 1.50 Sqmm single core PVC insulated, unsheathed cable FRLSH, 1100 volt grade with multi stranded copper conductorgreen colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box/metal flush box with suitable modular or pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer bothinternally and externally including provision of new 3 mm thick plastic laminated sheet top cover for housing the switches, socket outlets, fan regulators, etc. with brass screws and brass washersand making goodthe disturbed surfaces as per existingfor one light point controlled by one switch. Note :- Switch, socket and fan regulators to be measured and paid for separately . PVC Conduit confirming to IS 9537 part I & III Note (All chases will be cut by chase cutter only) 119 Description all as per Srl item No.119 here in before but for socket outlet point 5 Amp on same board. 120 Description all as per Srl item No.119 here in before but for socket outletpoint 5 Amp on Independent board. 121 Description all as per serial item No.119 above but with 4 sqmm cablefor 3 pin 15 Amps switch socket outlet (Power point) 122 S&F modular switch 1 way 6 A module 230/250 volt , AC supply,ISI Marked, with white cover plate with frame all as specified and directed. 123 S&F modular switch 1 way 16 A module 230/250 volt, AC supply,ISI Marked, with white cover plate with frame all as specified and directed. 124 S&F modular sockets 6A,2/3 pin combined 2 module 230/250 Volts,50 Hz , AC supply, ISI Marked, with cover plate all as specified and directed. 125 S&F modular sockets 6A/16A,2/3 pin combined 2 module 230/250 Volts,50 Hz , AC supply, ISI Marked, with white cover plate with frame all as specified and directed. 126 S&F in repairs Modular type AC Box, 4 Module with Socket and 25 Amp SP mini MCB in plastic box enclosure along with cover plate and top all as specified and directed. 127 S&F modular Fan step/ electronic regulator, 120W - 2 module A module 230/250 volt , AC supply,ISI Marked, with cover plate all as specified and directed. 128 S&F ceiling rose surface bakelite 65x50mm, 3 terminal all as specified and directed. 129 S&F LED lights fitting 1x 20W, 220V, AC decorative box type, warm white / white type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete pre wired fixed to wallwith 2 nos PVC block of suitable size all spcifided and directed. 130 S&F LEDWall bracket decorativefancy light fitting warm white /white type with lamp 12 Watt with necessary connection all as specified and directed. 131 S&F LED down lighter 15 watt warm white fancy light fitting warm white /white type with lamp 12 Watt with necessary connection all as specified and directed. 132 S&F Exhaust fan 230 volts, 250mm, plastic body includingmaking all electric connection all as specified and as directed including cutting of hole on wall and makng good disturbed surface of wall and outer wooden box for fan fix on wall all as specified and directed. 133 S&F Ceiling fan complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDCmaking all electric connection. huck and suitable size rod for hanging ceiling fan all as specified and directed 134 S&F LED security Buildinglight LED 35 Watt, pressure die cast aluminum housing, heat resistant glass, IP65 protection, better optics for uniform distribtion complete with all accessories internally pre wired and including connecting up with three core 1.5 sqmm flexible copper conductor cable from ceiling rose to connector of light all as specified and directed. 135 S&F in repairs MCB Distribution board, 240 volts single pole andneutral, double door, sheet steel, enclosure powder coated with 100 Amps rated busbar with neutral link, 12 ways , fixed on wall duly grouted in solid block wall or on wooden board with electrical connection, including taking down old MCB DB all as specified and directed. 136 S&F in repairs MCB DP,240 Volts, 40 Amps, 10 kA rupturing capacity C series all as specified and directed including taking down old one all as specified and directed. 137 S&F in repairs MCB, single pole 240 volts 6 to 32 Amps capacity fixed in DBsincluding taking down old one all as specified and directed. 138 S&F in repairs MCCB DB 4 way vertical sheet metal enclosure TPN 415 volts, 50 Hz, with IP-43 protection, double door with200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting all as specified and directed.Note:MCB SP/TPN shall be measured and paid seperately under appropriate items of this schedule Note:Copper thimble shall be used for connection of cable . 139 S&F in repairs MCCB TPN, 240 Volts, 63 to 100Amps, 10 kA rupturing capacity 415 Volts all as specified and directed including taking down old one. 140 M&Lin repairs Sub main wiring with two run of 6 sq mm stranded copper conductor PVC unseathed FRLSH wire along with 6 sq mm green colour wire as earth contuinity conductor connected to common earth dolly including PVC FR heavy duty conduit of adequate size (not less than 32 mm dia) for housing the wires from Pannel / Main DB to house SPN DB including taking down old Unsv submain with all associated fixtures complete all as specified & as directed by engr-in-charge.Note: Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. Note: Mode of measurement two runs of 6 sqmm cable and one run of 6 sqmm cable with PVC conduit shall be measured as one length. 141 M&L in repairs Sub main wiring with two runs of single core 4 Sqmm FRLSH copper conductor cable PVC insulated, unsheathed, 1100 V including 20 mm dia Cassing cappingISI markedwith all accessories such as Tees, elbows, junction boxes, etc. as required fixed on wall alongwith one run of 4 Sqmm single core PVC FRLSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion inculding taking down old wiring etc complete all as directed.Note: (i) Two runs of 6 sqmm and one run of6 sqmm cable and one run of PVC conduit shall be measured as one RM. 142 M&L in repairs Sub main wiring with two run of single core 1.5 Sqmm FRLSH copper conductor cable PVC insulated, unsheathed, 1100 V including 20 mm dia Casssing cappiingISI markedwith all accessories such as Tees, elbows, junction boxes, etc. as required fixed on wall alongwith one run of1.5 Sqmm single core PVC FRLSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion inculding taking down old wiring all as specified and directed.Note: (i) Two runs of 1.5 sqmm and one run of1.5 sqmm cable and one run of PVC conduitshall be measured as one RM. 143 Supply & lay in trenches, floors, fix on wall/pole, passing through pipes etc. LT UG cable , 1100 volts grade, PVC/ XLPE insulated, with multistrandedaluminium conductors, armoured with galvanised steel wire or tape, gland, lugs etc. of size 35 Sq.mm 3.5core confirming to IS specifications including taking down existing cable all as specified and directed. 144 Supply, laying connecting and testing XLPE insulated, PVC sheathed, armoured LT electric power UG cable (heavy duty) with stranded aluminium conductor, 1100 Volts grade, cross sectional area 10 Sqmm, 2 core laid through duct/ pipe / in trench etc. including cable glands & lugs including taking down existing cable all as specified and directed. 145 Shifting and fixing, Checkingand make functional condition ofSplit type AC 1.5 /2 ton at installed new locations asper site requirements including bracket, gas charging, using new/ old copper tubefrom indoor to outdoor unit, necessary fixing materials all as specified and directedby Engineer-in- charge. 146 M&L for earthing complete with galvanised steel earth plate electrode 60 cm X 60 cm X 6 mm buried directly in ground vertically to a depth not less than 2.25 mtr deep below ground level with top edge of earth plate at a depth not less than 1.5 m below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, check nuts and washers, galvanised steel and protected by GI pipe 15 mm bore light grade & connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1, precast RCC (1:2:4) type B1 cover slab 30 cm X 30 cmX 5 cm with 10mm dia TMT bars 8 cm C/c both ways andone handle for lifting made out of 8 mm dia TMTbar, funnel, wire mesh, 20mm bore galvanised iron pipe (medium grade) for watering, charcoal or coke and salt in alternative layers, necessary excavation and earth work in any type of soil and including necessary testing on completion all as shown in Electrical Plate No 3 of SSR part -I.
BRR : 9138591
Urgent Repair & Maintenance Work To Arrest Severe Leakage To First & Second Floors, Replacement Of Entry Roof, Repairs To Toilets, Water Supply System, Providing Furniture , Construction Of Rcc Foot Bridge From Chandranandan Road And Painting Etc. In Customer Service Centre At Sabarimala Sh:Part A ( 1St Recall ) ; 1 Part A: Civil Maintenance 2 Sub Head No 1:- Painting 3 White Washing With Lime To Give An Even Shade : 4 Old Work ( Two Or More Coats ) . 5 Distempering With 1St Quality Acrylic Washable Distemper ( Ready Made ) Having Voc Content Less Than 50 Gm Per Ltr. Of Approved Manufacturer And Of Required Shade And Colour Complete As Per ManufacturerS Specification. 6 One Or More Coats On Old Work. 7 Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade : 8 Old Work ( Two Or More Coats Applied @ 1.43 Ltr / 10 Sqm ) Over Existing Cement Paint Surface. 9 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade : 10 One Or More Coats On Old Work. 11 French Spirit Polishing : 12 One Or More Coats On Old Work. 13 Sub Head No Ii:- Repairs 14 Repairs To Plaster Of Thickness 12 Mm To 20 Mm In Patches Of Area 2.5 Sq. Meters And Under, Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete, Including Disposal Of Rubbish To The Dumping Ground , All Complete As Per Directions Of Engineer-In-Charge. 15 With Cement Mortar 1:4 ( 1 Cement : 4 Fine Sand ) . 16 Replacing The Damaged Epdm Rubber Beadings In Aluminium Window Shutters Carefully Without Causing Any Damages To Frame Work Including Scaffolding As Required As Per The Direction Of Engineer In Charge. [ Payment Shall Be Made For Replaced Beading In Running Metre ] 17 Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm Dia Cp Brass Single Hole Basin Mixer Of Approved Quality And Make, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Required:- 18 ( A ) White Vitreous China Wash Basin Size 550X400 Mm With A 15 Mm Cp Brass Single Pillartap 19 Providing And Fixing P.V.C. Low Level Flushing Cistern With Manually Controlled Device ( Handle Lever ) Conforming To Is : 7231, With All Fittings And Fixtures Complete. 20 10 Litre Capacity - White 21 Providing And Fixing P.V.C. Waste Pipe For Sink Or Wash Basin Including P.V.C. Waste Fittings Complete. 22 Flexible Pipe 23 32 Mm Dia 24 Providing And Fixing Mirror Of Superior Glass ( Of Approved Quality ) And Of Required Shape And Size With Plastic Moulded Frame Of Approved Make And Shade With 6 Mm Thick Hard Board Backing : 25 Rectangular Shape 453X357 Mm 26 Providing And Fixing Uplasticised Pvc Connection Pipe With Brass Unions : 27 45 Cm Length 28 15 Mm Nominal Bore 29 Dismantling Old Plaster Or Skirting Raking Out Joints And Cleaning The Surface For Plaster Including Disposal Of Rubbish To The Dumping Ground Within 50 Metres Lead. 30 Providing Rectifications To The Rcc Sloped Roof By Filling The Cracks Developed On The Surface With Crack X Paste Or Equivalent Applied After Making V Grooves Along The Crack Line Including Scaffolding If Any Required All Complete As Per The Direction Of Engineer-In-Charge 31 Engaging Labours To Find Outthe Causes Of Water Leakage In First Floor & Second Floor Roofof Csc Building Including Cost Of Scaffolding, Tools Etc. Complete As Per Direction Of Engineer-In-Charge. 32 Sub Head No Iii:-Roofing & Grill Work At Entry. 33 Dismantling Roofing Made Of Polycarbonate Carefully Without Causing Any Damages To The Steel Supporting Structure Including Disposal Of Unserviceable Materials Out Side The Periphery Of The Compound 34 Providing And Fixing Solid Core Polycarbonate Sheets Of Approved Make Fixed Using Self Drilling / Self Tapping Screws Of Size ( 5.5X 55Mm ) With Epdm Seal, Complete Upto Any Pitch In Horizontal / Vertical Or Curved Surfaces Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape, Rubber / Aluminium Beadings At Joints And Applying Silicone Sealent Wherever Required As Directed By Engineer-In-Charge 35 3Mm Thick Solid Semi Transparent Sheet 36 Steel Work Welded In Built Up Sections / Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required. 37 In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works. 38 Sub Head No Iv:-Covering Balcony 39 Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections / Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber / Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. ( Glazing, Paneling And Dash Fasteners To Be Paid For Separately ) : 40 For Fixed Portion 41 Powder Coated Aluminium ( Minimum Thickness Of Powder Coating 50 Micron ) 42 For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required ( Fittings Shall Be Paid For Separately ) . 43 Powder Coated Aluminium ( Minimum Thickness Of Powder Coating 50 Micron ) 44 Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge . ( Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item ) : 45 With Float Glass Panes Of 5 Mm Thickness ( Weight Not Less Than 12.50 Kg / Sqm ) 46 Sub Head No V:-:Toilet Repair 47 Providing And Fixing Double Scaffolding System ( Cup Lock System ) On The Exterior Side Upto Seven Storeys Height Made With 40Mm Dia Ms Tube 1.5M Center To Center, Horizontal And Vertical Tubes Joining With Cup And Lock System With Ms Tubes Ms Tube Challies, Ms Clamps And Ms Staircase Systemsin The Scaffolding For Working Platformand Maintaining It In A Serviceable Conditionfor Required Duration As Approved And Removing It Thereafter.The Scaffolding System Shall Be Strengthened By Bracings Runners And Connections With The Building Etc Wherever Requiredfor Inspection Of Work At Requird Locaationsand Essential Safety Features For The Workers Etc Complete As Perthe Directions Of The Engineering In Charge .The Elevation Area Of The Scaffolding Shallbe Measured For Payment Purpos.The Payment Will Be Made Once Irrespective Of The Duration Of Scaffolding. 48 Identifying The Spout Pies Of The Suspended Slab At All Toilet Locations Andto Ensure That The Pipe Extends Beyond The Wall Surfaceand Drains Out Colected Water If Any As Per Directions Of Engineer In Charge 49 Dismantling W.C. Pan Of All Sizes Including Disposal Of Dismantled Materials I / C Malba All Complete As Per Directions Of Engineer-In- Charge. 50 Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Metres Lead. 51 For Thickness Of Tiles 10 Mm To 25 Mm 52 Demolishing Lime Concrete Manually / By Mechanical Means And Disposal Of Material Within 50 Metres Lead As Per Direction Of Engineer In-Charge 53 Providing And Laying Water Proofing Treatment In Sunken Portion Of Wcs, Bathroom Etc., By Applying Cement Slurry Mixed With Water Proofing Cement Compound Consisting Of Applying : 54 ( A ) First Layer Of Slurry Of Cement @ 0.488 Kg / Sqm Mixed With Water Proofing Cement Compound @ 0.253 Kg / Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours. 55 ( B ) Second Layer Of Slurry Of Cement @ 0.242 Kg / Sqm Mixed With Water Proofing Cement Compound @ 0.126 Kg / Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours Followed With Water Curing For 48 Hours. 56 ( The Rate Includes Preparation Of Surface, Treatment And Sealing Of All Joints, Corners, Junctions Of Pipes And Masonry With Polymer Mixed Slurry. ) 57 Providing And Laying Cement Concrete In Retaining Walls, Return Walls, Walls ( Any Thickness ) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets, Sunken Floor, Etc., Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering And Finishing : 58 1:3:6 ( 1 Cement : 3 Coarse Sand Including Manufactured Sand Derived From Recycled Concrete Aggregate ( Rca ) Up To 25% : 6 Graded Stone Aggregate 20 Mm Nominal Size Including Recycled Aggregate ( Ra ) ) . 59 Providing And Laying Rectified Glazed Ceramic Floor Tiles Of Size 300X300 Mm Or More ( Thickness To Be Specified By The Manufacturer ) , Of 1St Quality Conforming To Is : 15622, Of Approved Make, In All Colours, Shades, Except White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Jointing With Grey Cement Slurry @ 3.3Kg / Sqm Including Pointing The Joints With White Cement And Matching Pigments Etc., Complete. 60 Providing And Fixing 1St Quality Ceramic Glazed Floor Tiles Conforming To Is : 15622 ( Thickness To Be Specified By The Manufacturer ) Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge In Skirting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1Cement: 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3Kgper Sqm Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. 61 Providing And Fixing Approved Quality Pvc Trap Of Self Cleansing Design Complete, Including Cost Of Cutting And Making Good The Wall And Floors : 62 100 Mm Dia 63 Providing And Fixing Unplasticized Rigid Polyvinyl Chlordie Soil, Waste And Vent Pipe With Socket ( Conforming To Is 4985-1988 ) Of Pressure Class Of 4Kg / Sq.Cm. Including Jointing The Pipe With Solvent Cement. 64 110 Mm Dia 65 90Mm Dia 66 Providing And Fixing White Vitreous China Pedestal Type Water Closet ( European Type W.C. Pan ) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device ( Handle Lever ) , Conforming To Is : 7231, With All Fittings Andfixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required : 67 W.C. Pan With Isi Marked White Solid Plastic Seat And Lid 68 Sub Head No Vi:-Roof Repair 69 Cement Plaster 1:3 ( 1 Cement: 3 Coarse Sand ) Finished With A Floating Coat Of Neat Cement. 70 20 Mm Cement Plaster 71 Extra For Providing And Mixing Water Proofing Material In Cement Plaster Work In Proportion Recommended By The Manufacturers. 72 Sub Head No Vii:-Repairs To Water Supply System 73 Providing And Fixing Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge. : Internal Work - Exposed On Wall 74 20 Mm Nominal Outer Dia. Pipes. 75 25 Mm Nominal Outer Dia .Pipes. 76 32 Mm Nominal Outer Dia. Pipes. 77 40 Mm Nominal Outer Dia. Pipes. 78 Providing And Fixing Gun Metal Gate Valve With C.I. Wheel Of Approved Quality ( Screwed End ) : 79 20 Mm Nominal Bore 80 32 Mm Nominal Bore. 81 Providing And Placing On Terrace ( At All Floor Levels ) Polyethylene Water Storage Tank, Is : 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank. 82 Providing And Fixing Ball Valve ( Brass ) Of Approved Quality, High Or Low Pressure, With Plastic Floats Complete : 83 25 Mm Nominal Bore 84 Sub Head Noviii-Rcc Foot Bridge 85 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) Including Dressing Of Sides And Ramming Of Bottoms, Lift Up To 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. 86 All Kinds Of Soil. 87 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 88 1:5:10 ( 1 Cement : 5 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 10 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources ) 89 Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level : 90 1:1.5:3 ( 1 Cement : 1.5 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) 91 Reinforced Cement Concrete Work In Walls ( Any Thickness ) , Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : 92 1:1.5:3 ( 1 Cement : 1.5 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Sizederived From Natural Sources ) 93 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 ( 1 Cement : 1.5 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Sizederived From Natural Sources ) . 94 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For : 95 Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete 96 Walls ( Any Thickness ) Including Attached Pilasters, Butteresses, Plinth And String Courses Etc. 97 Suspended Floors, Roofs, Landings, Balconies And Access Platform 98 Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers 99 Columns, Pillars, Piers, Abutments, Posts And Struts 100 Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level. 101 Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More. 102 Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. 103 Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More. 104 Smooth Finishing Of The Exposed Surface Of R.C.C. Work With 6 Mm Thick Cement Mortar 1:3 ( 1 Cement : 3 Fine Sand ) . 105 Sub Head No Ix: Balcony Roofing [ Second Floor ] 106 Steel Work In Built Up Tubular ( Round, Square Or Rectangular Hollow Tubes Etc. ) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. 107 Hot Finished Welded Type Tubes.
Disclaimer
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tender Detail
| Website | https://etender.cpwd.gov.in/login.html |
| Quantity | |
| MSME Exemption | No |
| Tender Type | Open Tender |
| Startup Exemption | Click Here |
| Competitive Bidding | NCB |
TENDER INSIGHTS
858
Electric TendersLive
Tell us about your Product / Services,
We will Find Tenders for you