Tender Summary / Eligibility Criteria
Tender For Augmentation Of 200 Kva Substation After Replacement Of Old Substation Equipment Including Accessories At Rrsl, Dhakhingaon, Kahilipara, Guwahati.
Documents
Download All
No Boq
No Corrigendum
Probable Bidders
AI engine predicts probable bidders to help you bid strategically.
MSME Exception
Technical
Tender involves procurement of high capacity electrical equipment including diaphragm coupling of pump &
motor with 90kW capacity at 2900 RPM. The project scope includes installation, testing, commissioning and
operational handover.
Previous / Similar Result
BRR : 2132996
Supply And Installation Of Equipment For State Of The Art Data Centre On Turnkey Basis To Beinstalled At Directorate Of Technical Education Office Kahilipara Guwahati Assam , hyper converge data center solution , installation & commissioning etc . complete installation , configuration integration , additional items cost should be included by the bidder during the submission of tender bid . at the time of installation and commissioning of the configuration if it is found that some additional hardware accessories ( san , switch / l3 switch / fc modules / hba card / fc patch cord / accessories etc ) or software items with licenses are required to complete the configuration to meet the operational requirement of the configuration which were not included in the vendors original list of deliverables then vendor is required to supply such items to ensure the completeness of the configuration at no extra cost . vendor should ensure completeness of the list of deliverables in the offer to avoid such discovery during installation .
BRR : 5202553
Erection For Replacement Of 40Mva, Bhel Make Transformer By 50Mva Transformer At Mahidpur 132Kv Substation Under 400Kv ( T ) Circle Nagda- 1 Erection of 50MVA Transformer for complete equipment on structure including shifting and placement within substation premises. 2 132KV CT complete equipment on structure including shifting and placement within substation premises. 3 132KV LA complete equipment on structure including shifting and placement within substation premises. 4 Erection of 33KV Isolator whithout earthswitch 5 Erection of 33KV Current Transformer 6 Erection of 132KV LA Structure 7 Dismantling of 132KV Current Transformer Equipment 8 Dismantling of 132KV LA Equipment 9 Dismantling of 33KV Isolator without earth switch Equipment 10 Dismantling of 33KV Current Transformer Equipment 11 Dismantling of 132KV LA Structure 12 Stringing and jumpring of Single Zebra Conductor 13 Stringing and jumpring of Double Zebra Conductor 14 Dismanting of Stringing and jumpring of Single Zebra Conductor 15 8 CORE :- Laying of Control Cable (in Mtrs) ( Laying of copper cables (armoured/un-armoured) on rackes/cable trays/angle support overhead racks conduits including dressing of cables with accessories glands,dressing of cable leads,fixing of tag. 16 12 CORE :- Laying of Control Cable (in Mtrs) ( Laying of copper cables (armoured/un-armoured) on rackes/cable trays/angle support overhead racks conduits including dressing of cables with accessories glands,dressing of cable leads,fixing of tag. 17 19 CORE:- Laying of Control Cable (in Mtrs) ( Laying of copper cables (armoured/un-armoured) on rackes/cable trays/angle support overhead racks conduits including dressing of cables with accessories glands,dressing of cable leads,fixing of tag. 18 4 CORE :- Cable Termination :- Termination connection of assorted size, cable (including providing holes, fixing of glands, drawing of cable, fixing of tag/ ferruls and making connection. (Both end) 19 8 CORE :- Cable Termination :- Termination connection of assorted size, cable (including providing holes, fixing of glands, drawing of cable, fixing of tag/ ferruls and making connection. (Both end) 20 12 CORE :- Cable Termination :- Termination connection of assorted size, cable (including providing holes, fixing of glands, drawing of cable, fixing of tag/ ferruls and making connection. (Both end) 21 19 CORE :- Cable Termination :- Termination connection of assorted size, cable (including providing holes, fixing of glands, drawing of cable, fixing of tag/ ferruls and making connection. (Both end) 22 Installation of earting material M.S. Flat (65x8mm) 23 Installation of earting material M.S. Flat (50x6mm)
BRR : 9088625
Tender For Augmentation Of Substation Equipment At Bkc Mtnl Mumbai-Servicing Of 1 No. Incomer And 2 Nos. Outgoing Of Vaccume Circuit Breaker Type Ht Panel I / C Megraing, Check Protection Relay, Ct, Pt, Tight Every Nut Bolt Of End Termination, Checking Of Circuit Breaker Mechanically Closing & Tripping, Replacement Of Faulty Bus Bar Insulator If Required Complete As Required. 2 Cleaning Of Ht Panel Inside Sheet With Sand Paper And Painting With One Coat Of Primer And Two Coat Of Enamel Paint. 3 Sitc Of Three Phase , 11 Kvcast Resincurrent Transformer Formetering Purpose. Current Transformer Of Rating ( 200 / 100 / 5 / 5 ) For 11 Kvht Panel. ( Note :- 1 Set Will Contains The 03 Nos. Of CtS ) 4 Sitc Of Three Phase 11 Kvcast Resin Potential Transformer Formetering Purpose.Potential Transformer Of Rating ( 11Kv / 110 Volt ) For 11 Kvht Panel. ( Note :- 1 Set Will Contains The 03 Nos. Of PtS ) 5 Repairing Of Faulty 11 Kv Vcb Panel Including Replacement Of All Three Number Vacuum Interrupters , Mounting Supports & Three Number Insulators , Cleaning Carbon From All Parts , Testing Ir Value Of Insulators , Spray ) .Remove All Damage Parts .Installing Vacuum Interrupter And Mounting Supports , Insulators , Repairer Mechanism System & On / Off Operation Complete As Required. 6 Sitc Of Following Accessories In The Existing 11 Kv Ht Panel: 7 A ) Ammeter Digital Typefor11 Kv Ht Panel 8 B ) Voltmeter Digital Type For 11 Kv Ht Panel 9 Supplying And Making Of Ht Cable End Jointing With Cast Resin Compound, Including Lugs And Other Jointing Materials, For 3 Core, Xlpe Aluminium Conductor ( Armoured ) Cable Of 11Kv / 22Kv Grade I / C Cutting, Removing The Existing Faulty Cable End Termination Wherever Required Etc. Complete As Required. ( Note: Make Of Jointing Kit- Denson / Raychem Or Equivalent ) Indoor Type Joint. 10 Servicing Of 1250 Kva Dry Type Transformer I / C Calibration, Meggraing, Cleaning, Checking Protection Relay, Complete Is Required.
BRR : 8964822
Up Gradation Of Substation Equipment At Te Building Andheri Mtnl Mumbai - Servicing Of 750 Kva Dry Type Transformeri / C Calibration, Meggraing, Cleaning, Checking Protection Relay, Ct Testing, Earthingtesting , Repairing Of Control Wiring , Check On Load, Disconnection And Reconnection Of Ht And Lt Side If Required, Complete Is Required. 2 Servicing Of One No. Ht Panel I / Cmegraing , Check Protection Relay, Ct, Pt , Indication Lamp, Amp. Meter , Voltmeter , Tight Every Nut Bolt Of End Termination, Checking Of Circuit Breaker Mechanically Closing & Trippingcomplete As Required. 3 Sitc Of Following Accessories In The Existing Lt / Mv Panel: 4 A ) Indicator Lamps Of Coloured Multiple Led Type 5 B ) S / F Selector Switch In The Existing Panel Including Wiring Etc Complete As Per Site Requirement. 6 Repairing Of Transformer Protection Relay I / C Display System , Control Wiring Complete As Required. 7 Servicing Ofall Rating Acb Complete With Cleaning, Alignment, Adjustment Of Gaps Between Phase To Phase, Lubricating All Moving Parts Adjustment For Smooth Mechanical Operation Etc Complete As Required. 8 Servicing Of Lt / Mv Panel With Mccb Of Any Rating As Incomer I / C Cleaning, Removing Carbon From Bus- Bars, Tightning Of All Connections & Nut-Bolts, Calibration Of All Meters, Replacement Of Faulty / Burnt Out Control Wiring, Testing For Proper Earthing And Submitting Test Reportetc. Complete As Required.
BRR : 1913770
Outsourcing Services For Manning And Operation Of Substations No 1 4 And 9 Under Age E_M Maint At Ina Ezhimala As Per Boq And Tender Documents , Note Applicable For All Items Of Boq:- ( For Special Attention Of Bidders ) If The Lowest Quoted Amount Is Less Than The Estimated Cost Of The Work Mentioned In Nit , The Lowest Bidder Will Have To Submit Fdr/Bgb In Favour Of Accepting Officer Within 7 ( Seven ) Days Of Opening Of Financial Bid For The Difference In Estimated Cost And Quoted Amount . In Case The Said Fdr/Bgb Is Not Submitted Within Stipulated Period As Mentioned Above , The Contractor Shall Be Banned For 6 Months And His Bid Will Be Rejected . Fdr/Gbg Will Be Released Only After Completion Of Entire Work And Production Of Proof For The Payment Of Wages To All The Workers Employed Under The Contract Is Paid Not Less Than The Minimum Wages Notified By The Central Govt . /State Govt . Whichever Is More , Outsourcing Services For Operation Of 11 Kv Substation No 1 Comprising Of Ht/Lt Switch Gears , Ht/Lt Machineries And All Connected Accessories Mentioned Below Round The Clock Including Sundays And Holidays By Employing Two Skilled Iti Qualified Electrician Per Each Shift ( 0600Hrs To 1400 Hrs , 1400 Hrs To 2200 Hrs And 2200 Hrs To 0600 Hrs ) And To Carry Out The Following Routine Works As Directed By Engineer- In- Charge . The Equipments Details Are:- ( A ) 11 Kv 400 Amps Vacuum Circuit Breaker With Relays And Controls - 07 Nos . ( B ) 11Kv/433 V Step Down Transformer Of Capacity 100 Kva - 01 No . ( C ) Lt Control Panel - 01 No . ( D ) 11 Kv Metering Panel - 01 No ( E ) Battery Bank With Battery Charger - 01 No . ( F ) Ht Bus Coupler With Ring Main Supply System - 01 Set ( G ) Dg Det 01 Nos , Outsourcing Services For Operation Of 11 Kv Substation No 4 Comprising Of Ht/Lt Switch Gears , Ht/Lt Machineries And All Connected Accessories Mentioned Below Round The Clock Including Sundays And Holidays By Employing One Skilled Iti Qualified Electrician Per Shifts ( 0600Hrs To 1400 Hrs , 1400 Hrs To 2200 Hrs And 2200 Hrs To 0600 Hrs ) And To Carry Out The Following Routine Works As Directed By Engineer- In- Charge . The Equipment Details Are :- ( A ) 11 Kv 400 Amps Vacuum Circuit Breaker With Relays And Control- 04 Nos . ( B ) 11 Kv Osfu 400 Amps- 03 Nos . ( C ) 11Kv/433 V Step Down Transformer Of Capacity 315 Kva- 02 No . ( D ) Lt Control Panel - 01 No . ( E ) Pf Improvement Capacitor Panel - 01 No . ( F ) Battery Bank With Battery Charger- 01 No . , Outsourcing Services For Operation Of 11 Kv Substation No 9 Comprising Of Ht/Lt Switch Gears , Ht/Lt Machineries And All Connected Accessories Mentioned Below Round The Clock Including Sundays And Holidays By Employing Two Skilled Iti Qualified Electrician Per Shifts ( 0600Hrs To 1400 Hrs , 1400 Hrs To 2200 Hrs And 2200 Hrs To 0600 Hrs ) And To Carry Out The Following Routine Works As Directed By Engr- In- Charge . The Equipment Details Are :- ( A ) 11 Kv 400 Amps Vacuum Circuit Breaker With Relays And Control- 11 Nos . ( B ) 11Kv/433 V Stepdown Transformer Of Capacity 500 Kva- 01 No . ( C ) 11Kv/433 V Stepdown Transformer Of Capacity 1000 Kva- 02 Nos . ( D ) Lt Control Panel - 03 Nos . ( E ) Pf Improvement Capacitor Panel - 01 No . ( F ) Battery Bank With Battery Charger- 01 No . ( G ) Ht Bus Coupler With Ring Main - 01 No . ( H ) Dg Set 320 Kva- 01 No . ( J ) Dg Set Panel - 01 No . , Notes For Sl Item No 02 , 03 & 04 ( I ) Spares If Any Required For Replacement Shall Be Supplied By Mes ( Ii ) The Tradesmen Shall Be Well Qualified In Respective Trade And Shall Wear Approved Uniform As Directed By Engineer- In- Charge While On Duty . He Shall Be Well Conversant With Preventive Measures ( First Aid ) In Case Of Electrical Accidents And Fire Fighting Systems And Maintain Log Books For Sub Stations ( Iii ) The Unit Rate Quoted Shall Include Stationery Required To Maintain Attendance Register , Duty Roster , Payment Register , Display Board , Complaint Register , Log Sheet And Other Register As Directed By Engineer- In-Charge . The Unit Rate Also Include Distilled Water , Grease Etc For Battery Maintenanance , Cleaning Materials Like Cotton Waste Etc . ( Iv ) The Contractor Will Prepare Duty Roster Well In Advance And Got It Approved By Engineer - In- Charge And One Copy Of The Roster Shall Be Displayed In The Notice Board . ( V ) Supplying Of Stationary , Uniform , Tool And Plant Required For Day To Day Maintenance For Sub Station Maintenance All As Directed By Engineer In Charge . ( Vi ) Contractor Is Fully Responsible For Cleanliness Of The Area Of Substations .
Disclaimer
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tender Detail
| Website | https://etender.cpwd.gov.in/login.html |
| Quantity | 0 |
| MSME Exemption | No |
| Tender Type | Open Tender |
| Startup Exemption | Click Here |
| Competitive Bidding | NCB |
TENDER INSIGHTS
858
Electric TendersLive
Tell us about your Product / Services,
We will Find Tenders for you