TDR : 56688516
gujarat energy transmission corporation limited

Tender Brief :

amreli, Gujarat

E-Tender 1) Amr/Cmc/Am/03/2026-27(3Rd A): Work Of 1) Erection, Commissioning Of Equipments,Testing, Control Wiring Etc, Of 1 Nos. 66Kv Bus Coupler Bay 2) Shifting Of 220Kv Class Existing Pt At 220 Kv Sagapara Substation Of Am Division Vartej Under Circle

Published: 28 Jul 2026
Opening: Ref Document
Closing: 12 Aug 2026
Amount: Ref. Documents
EMD: Ref. Documents
Tender Fee: Ref. Documents


Works Bio Gas Plant Diesel Power Plants Electrical Substation Gas Power Plants Geothermal Power Plants
11
Days Left
Tender Summary / Eligibility Criteria
E-Tender 1) Amr/Cmc/Am/03/2026-27(3Rd A): Work Of 1) Erection, Commissioning Of Equipments,Testing, Control Wiring Etc, Of 1 Nos. 66Kv Bus Coupler Bay 2) Shifting Of 220Kv Class Existing Pt At 220 Kv Sagapara Substation Of Am Division Vartej Under Circle Office Amreli, 2)Amr/Cmc/Tr/14/2025-26(8Th A): Bi-Annual Up Keeping. Housekeeping & Cleaning Work In Control Room Building, Office, Store & Switchyard Area With Grass Cutting & Removing As Well As Anti-Weed Treatment In Switch Yard At 220 Kv Vartej Substation Of Am Division Vartej Under Circle Office Amreli 3) Amr/Cmc/Tr/Vehicle/06/2026-27 (2D A): Híring Of Vehicle Of R.T.O, Taxi/Maxi Passing Suv/Muv (Petrol/Diesel) Closed Body Vehicle (Non-A.C.) (Minimum 8+1 Seating), 09 Seater Model For 66 Kv Lathidad Group Substation Of Getco, Am Division Dhasa Under Circle Office, Amreli Daily For 12 Hours In A Day And Monthly 3000Km For 2(Two) Years. The Vehicle Shall Not Have Been Registered Before More Than 03 Years On The Date Of Tender Openin
Documents Download All
3613a83f-1fd5-4f35-a7f3-a20b04a8105e
3613a83f-1fd5-4f35-a7f3-a20b04a8105e.pdf
No Boq
No Corrigendum
Probable Bidders

AI engine predicts probable bidders to help you bid strategically.

MSME Exception
Explore More →
Technical
Tender involves procurement of high capacity electrical equipment including diaphragm coupling of pump & motor with 90kW capacity at 2900 RPM. The project scope includes installation, testing, commissioning and operational handover.
Previous / Similar Result
BRR : 7296200 Tender For Construction Of 110 Kv Substation Kothakurussi - Erection Of Yard Structures And Equipments At 110 Kv Substation Kothakurussi-Capital work of 110kV Substation,Kothakurussi -Erection of Yard structures and Equipments at 110kV Substation Kothakurussi.-after dragging up to 50M using suitable lifting device carefully without causing any damage to equipments and fastening in the lorry make it ready for transportation as per the direction of the department officers. 2 Unloading one 110/66KV LA from department lorry to substation site using suitable lifting device and dragging to safe place without causing any damage to CT as per the direction of the department officers. 3 Loading one 110/66KV CT / CVT / PT / CC from the place of its storage to department lorry using required lifting device without causing any damage to equipment and its parts. 4 110KV CT, PT 5 110KV NCT 6 11KV NCT 7 Unloading one 110/66KV CT/PT/CVT/CC from department lorry to substation site using suitable lifting device and dragging to safe place without causing any damage to CT as per the direction of the department officers. 8 110KV CT, PT 9 110KV NCT 10 11KV NCT 11 Loading one set 110/66KV Circuit breaker with its interrupting poles, mechanism box, structures and all its accessories safely without causing any damage using necessary lifting devices to department lorry and fastening for transportation 12 Unloading one set 110/66KV Circuit breaker with its interrupting poles, mechanism box, structures and all its accessories safely without causing any damage using necessary lifting devices from department lorry to substation site and stacking properly for safe storage. 13 Loading one 110/66KV LA from the place of its storage to department lorry, if required, after dragging up to 50M using suitable lifting device carefully without causing any damage to equipments and fastening in the lorry make it ready for transportation as per the direction of the department officers. 14 11KV LA 15 Unloading one 110/66KV LA from department lorry to substation site using suitable lifting device and dragging to safe place without causing any damage to CT as per the direction of the department officers. 16 11KV LA 17 Loading one set 110/66KV Line Isolator with its insulator stacks, supporting channels, connecting pipes, isolating rods, earth switches, mechanism box, structures and all its accessories safely without causing any damage using necessary lifting devices to department lorry and fastening for transportation 18 Unloading one set 110/66KV Line isolator with its insulator stacks, supporting channels, connecting pipes, isolating rods, earthing rods, mechanism box, structures and all its accessories safely without causing any damage using necessary lifting devices from department lorry to substation compound and stacking properly for safe storage. 19 Loading 1x500 sq. mm XLPE cable from its place of storage to department lorry and properly without causing any damage to its insulation and make ready for transporting as per the direction of department officers. 20 Unloading 1x500 sq. mm XLPE cable from department lorry to substation site and stacking properly without causing any damage to its insulationas per the direction of department officers. 21 Loading MS / GI materials hard ware fittings of line work and clamps for equipments and bus from the place of its storage to department lorry and make it ready for transportation as per the direction of departmental officers. 22 Unloading MS / GI materials, hard ware fittings of line work and clamps for equipments and bus from department lorry to substation site and stacking for proper storage as per the direction of departmental officers. 23 Transportingby head load, the materials issued departmentally to the site from the place of storage and distribution to erection site 24 Drilling holes in yard structure 25 Cutting of steel angle in yard structure erection 26 Welding charge for welding on iron parts using arc welding as per standards 27 Fabrication of structures for erecting equipments. The GI & MS angles will be supplied departmentally 28 Erection of yard structures and assembling of columns and beams using bolt and nut including punching of holes. 29 Erection of 1 No. 110/66KV CT/PT/CVT/CC/220KV NCT on the already erected structure of above 1.5m height after opening of crates at the place of storage, leading to site carefully keeping at vertically not allowing tilting from vertical position more than the specified angles, keeping lines and levels as per the direction of the departmental officers, including all labour charges, hire charges of tools& tackles etc. 30 Conveying to the erection site and erecting carefully 1 No. 33KV CT/PT/110KV NCT & RVT/NCT(52/36kV) on the already erected structure after opening of crates at the place of storage leading to site carefully keeping at vertically not allowing tilting from vertical position more than the specified angles, keeping lines and levels as per the direction of the departmental officers, including all labour charges, hire charges of tools& tackles etc. 31 Erection of 1 No. 11KV CT/PT/11KV NCT on the already erected structure after opening of crates at the place of storage leading to site carefully keeping at vertically not allowing tilting from vertical position more than the specified angles, keeping lines and levels as per the direction of the departmental officers. 32 Erection of 1 No. 11KV LA (station type ) /11KV Post insulator on the already erected structure after opening of crates at the place of storage leading to site carefully, keeping lines and levels as per the direction of the departmental officers. 33 Erection of 1 No. 110/66KV LA/Post insulator on the already erected structure after opening of crates at the place of storage leading to site carefully, keeping lines and levels as per the direction of the departmental officers. 34 Erection of one set 110/66KV Bus Isolator on the already erected structure including opening crates and conveyance of all accessories from the place of storage to the place of erection to lines and levels, erection of mechanism box , checking operation and aligning properly, including cutting, welding etc.complete as per the direction of departmental officers. 35 Erection of one set 110/66KV line Isolator on the already erected structure including opening crates and conveyance of all accessories from the place of storage to the place of erection to lines and levels including erection of mechanism box checking operation and aligning properly as per the direction of departmental officers. 36 Unpacking carefully and leading one set of 3 pole EHT110/66KV Circuit Breaker from the place of storage, including support structure , mechanism box compressor, pipe lines etc. to site , cleaning and erecting on foundation using suitable lifting tools, after disassembling necessary parts if required, to lines and levels and assembling all the parts , connecting mechanism etc. in complete shape and making ready for commissioning as per the direction of departmental officers. 37 Uncoiling, paving out, stringing and fixing of bus bar using ACSR Kundah / Moose single conductor for one phase of 66/110KV bus of span up to 30M by cutting the conductor to sufficient length, crimping using compressor / bolting the two ends, washing, cleaning and drying the insulator discs, fixing the conductors to the yard structure with sufficient tension using string of insulators and hardware complete. at both ends, fixing of arcing hornes including transportation of materials from the stockyard to the site under the supervision and direction of department staff at site.(All materials will be supplied departmentally at free of cost). 38 Stringing and fixing earth wire of size 7/9, 7/10 or 7/3.15 between top of the columns and to terminal tower at 33/66/110/220KV substations with compressed / bolted ends at proper tension including uncoiling and cutting of conductor , jumpering, giving earth bond connections by drawing the end of the conductor through the columns, jointing where ever necessary providing back stays at the time of stringing etc. as per the direction of the departmental officers. 39 Providinginterconnection between equipments using ACSR Moose/ Kundah/ wolfSingle conductor at both ends with compressed/ bolted ends including uncoiling and cutting of conductor as per the direction of departmental officers. 40 Providing droppers and connecting to lines / equipments or jumper between two buses without suspension insulators using ACSR Moose/ Kundah/ wolfSingle conductor at both ends with compressed/ bolted ends including uncoiling and cutting of conductor as per the direction of departmental officers. (For one phase) 41 Laying of departmentally supplied GI strip/Copper strip of suitable sizeincluding cleaning and neatly bending of strips ,cutting, removing of metal/earth in the yard and burying earth strip to the required depth re-doing the yard metalling as per the direction of the departmental officers. 42 Welding one end of the bended GI strip of size 50x6mm with the riser of the already laid earth mat, welding 150mm in length, 6mm thick on both sides & end of the strip & other end of the strip with yard structure at 2 points 50mm apart each welding points having 50mm length and 6mm thick on both sides & end of the strip including the charges for connecting the strip with structure using bolted joints as per the directions of the department officers. Charges includes hire charges of DC arc welding set, current charges, cost of low hydrogen content DC arc welding electrodes(No.E7018) cost of anti corrosive paint etc. complete.(Structure earthing) 43 Welding overlapping joints of 50x6mm GI strip with 50mm long, 6mm thick welding on all three sides after doing 2 Nos. bolted joints at the centre as specified after cleaning the surface. Charges includes hire charges of DC arc welding set, current charges, cost of low hydrogen content DC arc welding electrodes( No.E7018) cost of anti corrosive paint etc. complete. 44 Welding one end of the bended GI strip of size 50x6mm with the riser of the already laid earth mat, welding 150mm in length, 6mm thick on both sides & end of the strip and connecting other end with nuts & bolts if required as per the directions of the department officers. Charges includes hire charges of DC arc welding set, current charges, cost of low hydrogen content DC arc welding electrodes(No.E7018) cost of anti corrosive paint etc. complete.(Equipment earthing) 45 Welding one end of the GI strip 50x6mm with the structure with a welding length of 50mm & 6mm thickness on both sides & end of the strip and connecting other end with bolts & nuts if required including hire charges of DC arc welding set, current charges, cost of low hydrogen DC arc welding electrodes (No.E7018) cost of anti corrosive paint etc. complete. 46 Fixing departmentally supplied marshalling kiosk in the existing PT/CT structure by making suitable fixing arrangements including cutting , welding, drilling holes etc as required. 47 Collecting from store or substation wherever available tools and materials such as jacks pulling and lifting machines,rails,sleepers, plies, ropes, empty drums, dummy plates, bolts and nuts gaskets, etc. including loading and unloading in department vehicle and accompanying and returningthe same after completing the work as per the direction of departmental officers.( Only if required) 48 Unloadingthe power transformers of weight 20T to 30T, carefully and safely inch by inch inserting railsand trawling to the platform made with sleepers and thus lowering very carefully inch by inch for placing on the rail track and hoisting to the plinth with out causing damage to transformer and accessories as per the direction of the departmental officer observing all safety precautions. 49 Pulling the power transformers of weight 20T to 30T, on the rail track, travelling for a distance up to 30M, using sleepers, rails, jacking, pulling and keeping ready for placing on the correct plinth as per the direction of departmental officers at site, safely without damaging any equipments and observing all safety precautions. 50 Loading to the department lorry the accessories of 10/12.5MVA transformer such as bushings with proper package, coolers, conservator tank, connecting pipes, bolt and nuts, wheels, rollers, fans, driving mechanism, cooler control box and oil drums etc. safely fastening them properly, accompanying the vehiclewith transformer from ……………….. to ……………and unloading and stacking in convenient place, taking all safety precautions as per the direction of departmental officers. 51 Assembling the 10 /12.5 MVA, 110/11 or 66/11KV transformer with all accessories in complete shape and filling oil if required including arresting the movement of the transformer by locking as per the direction of the departmental officers. 52 Covering the transformer with tarpaulin using ropes, bamboos etc. 53 Giving three phase connection to the filter unit from the supply mains using cable including fitting three numbers of fuse units near the filter unit and laying the cable from control room to filter unit and trial run of filter unit after giving connection etc. complete. ( Only iffound absolutely necessary and where departmental staff is not available ). 54 Hot oil circulation after draining oil from transformer, evacuating the transformer by using vacuum pump after providing LT connection to the pump , connecting the hose to transformer, operating carefully and continuously for attaining sufficient vacuum and keeping in vacuum for 24 hours and operating filter unit carefully and continuously for 24 hours except halt due to poor voltage and trouble in filter plant etc complete as per the direction of dept. officers. 55 Disconnecting the power connections to the filtering plant/ vacuum pump, coiling the cable, disconnect the hoses and coiling them and folding and removing tarpaulin used for covering the transformer, moving the filter plant and vacuum pump to a distant place as directed by the department staff. ( where departmental staff is not available and is found absolutely necessary) 56 Loading the 6000/5000litre/hr.or above transformer oil filter plant tolorry using tripod, chain block, pulley block, rope etc., after pulling it to the convenient position for lifting and fixing it firmly for safe transportation to the location as directed by department officers, unloading the same without causing any damage and placing it carefully at convenient place etc. complete as directed by department officers at site where ever required. 57 Turning and shifting 6000 L/H capacity transformer oil filtering plant or wheel mounted 10000/15000 Litre. oil tank with all accessories for a distance of 20Mto road, towingthe machine with department lorry by the use of D-Shackle and iron ropes , accompanying the lorry including supervision through out the journey especially in turnings to avoid falling of plant. Remove the machine from the lorry and drags up to 10M for safe storage where ever required. 58 Loading the empty oil tank of capacity 10000/15000 Ltr. From the place of its storage using wooden blocks, lever etc. and moving the tank to a distance of 10M from switch yard then loading the same to the dept. vehicle using chain pulley etc. carefully tying the tank in vehicle accompanying the vehicle up to Kothakurussisubstation, removing ties andunloading the tank carefully by the use of wooden blocks rails, chain pulley etc. again moving the tank to a distance of 50M, for safe storage. 59 Loading one vacuum plant of capacity 3HP with its pipelines to department lorry and unloading the same at the required substation as per the direction of departmental officers. 60 Laying 1 x 500 sq mm XLPE cables in trench including drawing through pipes wherever necessary 61 Doing out door/indoor cable termination of 1x500 mm2 11KV XLPE cable very carefully observing directions of manufactures and departmental staff including crimping of socket 62 For mounting 1 x 500 mm2 out door / indoor cable termination 63 Unpacking the transformer / feeder C&R panels, 110V battery charger, OLTC cubicle LT panel at the place of storage transporting to the place of erection and erecting after providing foundation bolt keeping to lines and levels as per the direction of departmental officers. 64 Unpacking at the place of storage and transporting 11KV indoor VCB/SF6 switch gear panel and its accessories to the place of erection and erecting after fixing foundation bolts by chipping concrete wherever necessary, tightening, keeping lines and levels taking all safety precautions including erection of potential transformers as per the direction of departmental officers. 65 Interconnection of panels and 11KV bus bars after opening covers, earthing, inter panel wiring, etc. and making ready for commissioning of breaker as per the direction of the departmental officers. 66 Assembling 55 cells of 100AH conventional battery, pore the acid in required level, connect the battery to the charger and charge to the required specific gravity level, check the specific gravity and voltage of each cells hourly. After attaining the required specific gravity and voltage keep the same for 24 hours, discharge the same up to 50% of the rating and then boost charge the same monitor the voltage and specific gravity regularly and make the battery ready for station use. 67 For 200AH Battery 68 Preparing wiring schedule per transformer / feeder bay of 110 or 66kV with details of type of cable, core and colour, ferrule No. and terminal no of equipments/panelsincluding giving full details in A4 sheet with computer print providing outer border line and sheet no etc. and supplying in the shape of book with special binding etc. and assisting the departmental officers at the time of relay testing and commissioning 69 Master Copy 70 Additional Copy 71 Uncoiling 20/19 core 2.5sqmm, 12 core 4 sqmm control cable (Armoured or un armoured) from cable drums cutting to required length and laying through trench/pipe/cable tray grouping the same neatly using cable tie and carefullyincluding for providing loop wherever necessary and providing cable marker at both ends of cable as per direction of departmental staff at site. 72 Uncoiling 12/7/6 core 2.5 sq mm control cable (armoured and un armoured) from cable drums and cutting to required length and laying through trench/pipe/cable tray grouping the same neatly using cable tie and carefullyincluding for providing loops wherever necessary and cable marker, at both ends of cable as per direction of departmental staff at site. 73 Uncoiling 4/2 core 2.5sqmm control cable (armored or unarmored) from cable drums and cutting to required length and laying through trench/pipe/cable tray neatly and carefully including for providing loops wherever necessaryand cable marker at both ends of cable as per direction of departmental staff at site. 74 Uncoiling 5/4/3/2 core 4sqmm control cable(armoured or un armoured) from cable drums and laying through trench/pipe/cable tray neatly and carefully including for providing loops wherever necessaryand cable marker at both ends of cable as per direction of departmental staff at site. 75 Fixing all type of terminal connecting strip with terminal connectors in the marshalling box or panel boardwherever necessary (terminal connecting strip will be supplied departmentally ) charges includes for providing necessary suitable hole etc complete as per direction of departmental staff at site. 76 Termination of cables in panel by using cable glands of fixing the cable rigidly by any means as per direction of departmental staff at site charges include for providing necessary suitable hole in the gland plate etc. 77 20/19 core 2.5sqmm cable/12 core 4 sqmm cable (using gland of size 28-32mm) 78 12/7/6 core 2.5 sqmm cable (using gland of size 25mm) 79 4/2 core 2.5 sq mm cable/4/2 core 4 sq mm cable (using gland of size 16-22mm) 80 Doing termination of all sizes of PVC insulated copper control cable 2.5mm², pealing, providing number and letter ferrules in the wire, stripping ends, crimping with suitable lugs and connecting to the terminals in the panel board and marshalling kiosk etc., neatly and carefully including cost of copper sockets and ferrules as per the direction of Departmental Officers at site. 81 Doing termination of all sizes of PVC insulated copper control cable 4.0 mm², pealing, providing number and letter ferrules in the wire, stripping ends, crimping with suitable lugs and connecting to the terminals in the panel board and marshalling kiosk etc., using cable tieand cable tie neatly and carefully including cost of copper sockets and ferrules as per the direction of Departmental Officers at site. 82 Supplying aluminium cable tags punching number and alphabets up to 7 digits and binding to cable using copper wire including cost of all materials as per the direction of Board Officials at site. 83 Making of cable clamps using 25x 3 mmGI strip (hot dipped)as per no of cablesin cable tray cutting and holing to required length and for fixing as per the direction of departmental officers at site including supply of suitable nut and bolts. 84 Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m., asdirected by Engineer-in-Charge: All kinds of soil 85 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 86 Supplying and laying tarpaulin sheet of thickness 150GSM of approved make and quality over levelled surface including cost of tarpaulin sheet, wastage overlaps, conveyance and labour charges ect. Complete. 87 Supply and stacking Stone Aggregate (Single size) : 20 mm nominal size 88 Spreading 40mm stone aggregate/20mm stone aggregate in the yard about thickness of 15cm as per the direction of department officers at site 89 Conveying of precast RCC slabs (of various size) manually from stacking place within initial lead etc. complete and laying carefully in position without damaging the edges of slabs as well as cable trench side wall as per directions of Engineer-in- Charge. 90 Loading HT A type pole from the stacking place and unloading the same at work site (transport by vehicle). 91 Transporting poles by hired vehicle to a distance upto 5km and carrying upto 4 poles excluding loading & unloading. 92 Fitting and erecting one HT DP using A type pole in position incl. fitting 2 channel cross arms, digging & back filling pit, drawing earth leads. 93 Drilling hole of various sizes on existing Channel/Cross Arm. 94 Additional rate for excavation of Pit for A type pole in Hard Laterite. 95 Providing one Earth using earth pipe including digging separate pit at standard distance away from the pole/structure & backfilling. 96 Additional rate for excavation of one Earth Pit (2.5m depth) in Hard Laterite 97 Fitting one Additional 3m Channel cross arm (35x35x5mm), in existing 11kV DP incl. conveyance of materials. 98 Erection of one set 11KV Isolator / AB switch (station class)on the already erected structure including opening crates and conveyance of all accessories from the place of storage to the place of erection to lines and levels including erection of mechanism box checking operation and aligning properly as per the direction of departmental officers. 99 Erecting one 250kVA Transformer to existing Plinth/Platform and giving connections,includingloading from TMR/SRS/other stacking place & unloading at site but excluding cost for transporting transformer 100 Providing concrete muffing (0.45x0.45x1.5m) inclusive of cost of all material (as per specification). 101 Loading 3x300 sq. mm XLPE cable from its place of storage to department lorry and properly without causing any damage to its insulation and make ready for transporting as per the direction of department officers. 102 Unloading 3x300 sq. mm XLPE cable from department lorry to substation site and stacking properly without causing any damage to its insulationas per the direction of department officers. 103 Laying 3 x 300 sq mm XLPE cables in trench including drawing through pipes wherever necessary. 104 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11KV gradedirect in ground including excavation, sand cushioning,protective covering and refilling the trench etc as required. 105 Doing out door/indoor cable termination of 3x300 mm233KV XLPE cable very carefully observing directions of manufactures and departmental staff including crimping of socket 106 Mounting one 3x300 mm2 XLPE out door cable termination of structures very carefully without causing any damaged to the drilling holes wherever necessary as directed by the departmental officers 107 Random rubble masonry in CM 1:6 for foundation and basement including cost of all materials, conveyance, labour charges, etc. complete as perspecifications.
Contract Date : 29 Apr, 2025   |   Contract Value : 45.02 Lakhs
BRR : 5950310 Bids Are Invited For 1 - Supply & Replacement Of 33Kv Oil Immersed Outdoor Type Ct Dual Core Dual Ratio 300-150/1-1A Core -1 Class 1 & Core 2 Class 5P10. The Job Incldes The Dismantling Of Existing Ct & Installation Of New Ct With All Connection Temination Etc. Complete In All Respect , 2 - Supply & Replacement Of 33Kv Oil Immersed Outdoor Type Ct Dual Core Dual Ratio 150-75/1-1A Core -1 Class 1 & Core 2 Class 5P10. The Job Incldes The Dismantling Of Existing Ct & Installation Of New Ct With All Connection Temination Etc. Complete Is All Respect , 3 - Shifting Of C&R Panel From Existing Place To Other Place Including Dismantling Of Same And Opening Of All Existing Connections & Shifting Of C&R To Other Place & Installation & Termination Of All Cables Etc At New Location , 4 - Supply & Laying Of Control Cable From Ct To C&R Panel Installed At New Location 6 Core 2.5 Sqmm Copper Armoured Cable , 5 - Supply & Laying Of Control Cable From Pt To C&R Panel Installed At New Location 6 Core 2.5 Sqmm Copper Armoured Cable , 6 - Supply & Laying Of Control Cable From 33Kv Vcb To C&R Panel (A.C. Supply) Installed At New Location4 Core 2.5 Sqmm Copper Armoured Cable , 7 - Supply & Laying Of Control Cable From 33Kv Vcb To C&R Panel (Dc Supply) Installed At New Location 2 Core 2.5 Sqmm Copper Armoured Cable , 8 - Supply & Laying Of Control Cable From 33Kv Vcb To C&R Panel (Control Connetctions) Installed At New Location12 Core 2.5 Sqmm Copper Armoured Cable , 9 - Supply And Laying Of 3 Core 70Sqmm Standered Aluminium Conductor Xlpe (Cross Linked Polyethylene) Insulated Pvc Bedded, Galvanised Flat Steel Strip Armoured Cables Confirming To I.S.7098 (Part-Ii With Latest Amendments) Iikv Grade. The Armouring Of Cable Shall Be Properly Connected With Earth Conductor By Clamps Etc. , 10 - Horizontal Direction Drill At 1Mtr , 11 - Supply & Laying Of Dwc Pipe Dia 100Mm With All Socket Etc. Complete In All Respect , 12 - Cable Jointing Of 11 Kv Grade 3 Core 70Sqmm Xlpe Insulated Armoured Cable With Suitable Cable Termination Using Raychem/Birla 3M/Mecp Kits Including All Accessories I.E. Sockets, Lugs, Gland Etc As Required But Without Cable Box. , 13 - Supply & Fixing Of Transformer Protection Relays (Oti, Wti & Wti). The Relays Shall Be Manual Reset Type With Hr Flag Control Supply Voltage Shall Be As Per Site Requirement. The Job Includes The Making Necessary Cutout In Existing Panel And Fixing Of Relays Along With All Required Wiring Testing Etc. Complete In All Respect , 14 - Supply & Burying Of Safe Earthing Electrode T-39 Zn. Zinc Coated, Length 3000Mm, Outer Pipe 76.3Mm X 3.2Mm Inner Pipe 42.4Mm X 2.6Mm, Terminal Dia 12Mm, Coating 80-100Micron Filled With Crysteline Conductive Mixture (Ccm) Havinbg Anti Corrosive & Conductive Properly With 50Kg Activated Soil (Bfc) Capable Of Reducing The Soil Restivity With Good Mixture Of Retaining Capacity And One Earthing Lead Of 20 X 3 G.I. Strip Upto Switch Board With 30Cm Square C.I. Frame With Hinged Cover & Masonary Housing. , 15 - Supply And Burring Of Safe Earthing Electrode T-39 Cu Copper Coated, Length Up To 3000Mm, Outer Pipe 76.3Mm X 3.2 Inner Pipe 42.4Mm X 2.6Mm, Terminal Dia 12Mm, Coating 80-100 Micron Filled With Crystalline Conductive Mixture (Ccm) Having Anti Corrosive & Conductive Property With 50 Kgs Activated Soil (Bfc) Capable Of Reducing The Soil Resistivity With Good Mixtureof Retaining Capacity Along With 30 Cm Square C.I. Frame With Hinged Cover & Masonry Housing. , 16 - Supply & Laying Of 32 X6 Mm G.I. Strip From Earth Electrode Directly In Ground As Required Complete In All Respect. , 17 - Supply & Laying Of 50 X6 Mm Copper Strip From Earth Electrode Directly In Ground As Required Complete In All Respect. , 18 - Supply,Instattion,Testing And Commissioning Of Ese Lightning Protection The Works Includes With Lightningprotection System,Lighning Counter,Earth Electode,Earth Enhancing Compound,Hdpe Chamber,Busbar Ms Mast And Earth Strip Complete In All Respect. , 19 - Supply And Laying Of 1800Mm X 900Mm X 12Mm Thick Chequered Rubbbber Matting Of Tested Quality. , 20 - Supply, Installation, Testing And Commissioning Of 5Mva Onan Transformer 33 Kv/ 11V, 3 Phase, 50 Hz Delta/Star Connected, Outdoor, Oil Filled, Completewithall Fittings Such As Thermometers, Buchholz Relay, With Off Circuit Tapp-Changer + 5 % To –15%, Tapping At The Step Of 1.25% With Rating Plate & Winding Temperature Indicator & Protection , Oil Temperature Indicator & Protection, Lifting Lugs, H. T. Cable Box/ Lt Box Etc. , 21 - Supply, Installation, Testing And Commissioning Of One Set 33Kv, 1500Mva Indoor Type Metal Clad Floor Mounted Vermin Proof Horizontal Drawout Fully Interlocked Vertical Isolation Vacuum Circuit Breaker Panel Board Fabricated Out Of Minimum 2Mm Thick Crca Sheet As Per Specifications. The Panel Shall Be Complete With All Accessories / Fitting / Wiring Like Insulated Copper Busbar, Cable Termination Boxes Suitable For 3C X 300 Sqmm Xlpe Armoured, Aluminium Conductor Cable For Incoming And Outgoing Feeder, Foundation Bolts Etc. Complete As Required And As Per Attached Specified , 22 - Supply And Laying Of 3 Core 240Sqmm Standered Aluminium Conductor Xlpe (Cross Linked Polyethylene) Insulated Pvc Bedded, Galvanised Flat Steel Strip Armoured Cables Confirming To I.S.7098 (Part-Ii With Latest Amendments) Iikv Grade. The Armouring Of Cable Shall Be Properly Connected With Earth Conductor By Clamps Etc. , 23 - Cable Jointing Of 33 Kv 240Sqmm Grade Xlpe Insulated Armoured Cable With Suitable Cable Termination Using Raychem/Birla 3M/Mecp Kits Including All Accessories I.E. Sockets, Lugs, Gland Etc As Required But Without Cable Box. , 24 - Supply, Installation, Testing And Commissioning Of 11Kv, Incoming Vcb Feeder Panel 26.3Ka Indoor Type Metal Clad Floor Mounted Vermin Proof Horizontal Drawout Fully Interlocked Horizontal Isolation Vacuum Circuit Breaker Panel Board Fabricated Out Of Minimum 2Mm Thick Crca Sheet As Per Specifications. The Panel Shall Be Complete With All Accessories / Fitting / Wiring Like Insulated Copper Busbar, Cable Termination Boxes Suitable For Upto 3C X 300 Sqmm Xlpe Armoured, Aluminium Conductor Cable For Outgoing Feeder, Foundation Bolts Etc. The Panel Shall Be Installed Along With Existing 11Kv Vcb Panel And Prices Quoted With Coupling Bus Bar To Be Connected The Above Panel With Existing Vcb Panel Along With All Alignemet & Conection. The Panel Shall Be Scada Compitable And Shall Be Provided With Suitable Metering To Measure Import / Export Energy Data On Scada Also. The Job Shall Be Completed As Per Site Requirement And As Per Attached Specification. , 25 - Supply Of Single Panel(1 Incoming + 5 Outgoing + 1 Bus Coupler Vcb Panel) Set 11Kv, 500Mva Indoor Type Metal Clad Floor Mounted Vermin Proof Horizontal Drawout Fully Interlocked Vertical/Horizontal Isolation Vacuum Circuit Breaker Panel Board Fabricated Out Of Minimum 2Mm Thick Crca Sheet As Per Specifications. The Panel Shall Be Complete With All Accessories / Fitting / Wiring Like Insulated Copper Busbar, Cable Termination Boxes Suitable Forupto 3C X 300 Sqmm Xlpe Armoured, Aluminium Conductor Cable For Incoming And Outgoing Feeder, Foundation Bolts Etc. Complete As Required And As Per Attached Specification , 26 - Overhauling Of 500Kva 11/.415Kv Distribution Transformer , 27 - Design And Manufacturing Of Moving Trollysuitable For 500Kva 11/.415Kv Transformer , 28 - Supply & Installation Of 33Kv Terminal Gantry With Structure To Receive 33Kv Power From Existing 33Kv Bus Available Already In Switchyard. The Job Includes All G.I. Structure, Steel Sections Xross Arms Etc. With Foundation, Painting Of Pole And Including Pin & String Insulator, Suppots Hardware Etc. , 29 - Supply, Erection, Testing And Commissioning Of 33 Kv 630 Amps Triple Pole Isolator With Earthing Heel As Per Latest Is:9921 (Pt-I To V) , 30 - Supply, Erection Of 33 Kv Current Transformer Single Phases Conforming To Is:2705(Pt.I To Iv) A) Core 1 (Metering) 150-75/1A Class 0.2, 20Va B) Core 2 (Protection) 150-75/1A Class 5P10, 20Va , 31 - Supply, Erection, Testing And Commissioning Of 33Kv 800 A, 1250 Mva Out Door Type As Per Technical Specification Enclosed Vacuum Circuit Breaker Complete As Per Latest Is:13118. , 32 - Erection Of 30Kv ,10Ka Lightening Arrestor With Insulating Base And Surge Counter As Per Latest Is:3070 Part I/1985 ( Latest Version) , 33 - Supply, Erection, Testing And Commissioning Of Control & Relay Panel For Single Transformerwith Suitable Protection And Controls For All Isolators & Vcb. The Panel Shall Be Scada Compitable And Shall Be Sujitable To Operated From Remote Control Station , 34 - Terminal Connector To Receive From 33Kv Line (Terminal Gantry) Suitable For Acsr Conductor , 35 - Terminal Connector To Receive To Bus Isolator Suitable For Acsr Conductor , 36 - Terminal Connector For Lightning Arrestor Suitable For Acsr Conductor , 37 - Terminal Connector For Ct Suitable For Acsr Conductor , 38 - Terminal Connector For Vcb Suitable For Acsr Conductor , 39 - Erection Of T Clamp For Acsr Conductor , 40 - Galvanised Structure For Lightning Arrestor With All Section Cross Arm Etc. , 41 - Galvanised Structure For Line Isolator With All Section Cross Arm Etc. , 42 - Galvanised Structure For Current Transformer With All Section Cross Arm Etc. , 43 - Galvanised Structure For Vaccum Circuit Breaker With All Section Cross Arm Etc. , 44 - Acsr Conductor 0.2 Inch(Nominal Area 200 Sqmm) , 45 - Marshalling Box For Ct , 46 - Misc Itms Other Than Above Items , 47 - Cordination, Engineering & Misc Job For Complete Substation , 48 - Supply, Erection, Testing And Commissioning Of Battery Charger Float Cum Boost Along With Input & Output Mcbs,Amp, Volts Meter, Interconnections Etc. Power Supply 230 V, 1 Phase, 50 Hz ± 10%. Charger Troubleannunciation Shall Be Provided Through Led. , 49 - Supply Erection Testing & Commissioning Of 100Ah Battery Bank Capacity Consisting Of 12Nos. 2V Tubular Cell Alongwith Mounting Cabinet And Copper Connection Leads Etc. , 50 - Pre Noc & Noc After Completion Of Work From Statuary Authority Is Essential For Every Service As Required. Viz.Electrical Panels, Transformers From Directorate Of Electrical Safety , State Government / Competent Authority. , 51 - Supply And Laying Of 400Sqmm 3.5 Core Aluminium Conductor Pvc Insulated Armoured Served Sheathed Cables 1100 Volts Grade At A Depth Of 750 Mm Below Ground Level Over A Cushion Of 75 Mm. Thick Sand All Around And Protected With Burnt Bricks On Sides And On Top. On Surface The Cable Run Shall Be Fixed On M.S. Clamps Etc. Of Suitable Size Or As Directed By The Engineer-Incharge, Complete In All Respect. The Armouring Of The Cable Shall Be Properly Connected With The Earth Conductor By Clamps Etc. , 52 - Supply And Laying Of 240Sqmm 3.5 Core Aluminium Conductor Pvc Insulated Armoured Served Sheathed Cables 1100 Volts Grade At A Depth Of 750 Mm Below Ground Level Over A Cushion Of 75 Mm. Thick Sand All Around And Protected With Burnt Bricks On Sides And On Top. On Surface The Cable Run Shall Be Fixed On M.S. Clamps Etc. Of Suitable Size Or As Directed By The Engineer-Incharge, Complete In All Respect. The Armouring Of The Cable Shall Be Properly Connected With The Earth Conductor By Clamps Etc. Total Quantity : 1
Contract Date : Ref. Documents   |   Contract Value : 4.88 Crore
BRR : 9231079 Tender For 66 Kv Substation Sullar; 1 25/31.5 MVA, 66/11kV T/Fs 2 66 kV SF-6 Breaker along with 20% extra SF-6 Gas 3 66 kV Isolator with E/Switch 4 66 kV Isolator without E/Switch 5 66 kV Surge Arrestor 6 66 kV CTs for Line & Bus Coupler (600-300-150/1-1-1A) 7 66 kV CT for T/F (300-200-150/0.577-1-1A) 8 66 kV PT for line 9 66 kV NCT (300-200-150/1A) 10 11 kV NCT (1800-900/5A) 11 11 kV Surge Arrestor 12 11 kV 15 Panel Board (2000A)(including one no. bus sectionalizer panel) 13 66kV C&R Panels with SAS:a) Bus Coupler Protection and Circuit Breaker Panel (Without Auto Reclose) with SAS 14 b) Line Protection and Circuit Breaker Panel (Without Auto Reclose) with SAS with line current differential- cum- distance protection relay 15 c) Transformer Protection and Circuit Breaker Panel (Without Auto Reclose) with SAS 16 9000 KVAR 12.65 kV Automatically Switched Capacitor Bank along with allied equipment as per technical specification 17 220V 100AH Battery San Tubular 18 220 V 20/30 A Battery charger (SMPS) 19 220V D.C.D.B. 20 415 V LT AC Distribution Board 300 A 21 11/0.4 kV Station T/F 200 KVA 22 (a) 1.1 kV Copper Control Cable unarmoured for 66kV bays of size 7Cx4mm2, 4Cx4mm2, 2Cx4mm2,2Cx6mm2, 3Cx2.5mm2, 16Cx2.5mm2, 10Cx2.5mm2 & 7Cx2.5mm2 including junction box etc. refer Section-5 of copper & control cable & Section-7 for switchyard erection. 23 (b) Stainless steel MK (200 TB) 24 11 kV Power Cable XLPE 1C x1000mm2 for T/F to 11kV incomer (4 run per phase for each transformer allocating them 2 runs per phase for each 11kV I/C). 25 Termination kit at both ends for 11 kV XLPE Power Cable(1C x1000 mm2 ) Termination kits for (indoor/outdoor) both ends alongwith assessories constitute a set of each cable. 26 11 kV Power Cable XLPE3C x 400sq mm for Capacitor Bank 27 Termination kit at both ends for 11 kV XLPE Power Cable( 3C x 400 mm2) Termination kits for (indoor/outdoor) both ends alongwith assessories constitute a set of each cable. 28 11 kV Power Cable XLPE 3C x 50 sq mm for station T/F 29 Termination kit at both ends for 11 kV XLPE Power Cable( 3C x 50 mm2) Termination kits for (indoor/outdoor) both ends alongwith assessories constitute a set of each cable. 30 650/1100 Volts 3.5 core 240 mm2 aluminium power cable from Aux. T/F to ACDB. 31 650/1100 Volt 3.5 core 70 mm2 aluminium cable for oil filtration set. 32 650/1100 Volt 4core 16mm2 unarmoured with copper power cable for MLDB and other cable required as per contract for 66 kV bays. 33 Earthing Mat Material. The earth mat will be designed/ quoted for soil resistivity of 50Ωm. In case soil resistivity is more than 50Ωm then the earth mat will be designed for actual soil resistivity. The payment of extra material to be used for earth mat shall be made on pro rata basis. The approximate area of earth mat to be laid is given in the corresponding columns of the substations. However, item will remain a Lot item. (calculations may be made considering fault/shock duration of 1 sec., 5400 m2) 34 Fire Fighting equipments as per section-6:i) 22.5 Kg Capacity FE CO2 type, Trolley Mounted 35 ii) 25 Kg Capacity FE DCP type, Trolley Mounted 36 iii) DCP 10 Kg Capacity, Wall mounted 37 iv) FE CO2 6.5 Kg Capacity, Wall mounted 38 v) DCP 5 Kg Capacity, Wall mounted 39 vi) Foam Type 9 Litre Capacity, Wall mounted 40 vii) Water CO2 9 Litre, Wall mounted 41 viii) Fire Buckets (12 Nos. with stand in one set) 42 Complete lightning of control room building, switch yard area, road and street as per section-7 of the specification:a) Supply and installation of 2 fittings of 240W LED lamps with all accessories for Complete lighting of outdoor Switch yard area as per clause 16.0 of section 7 of the specifications. 43 b) Supply and installation of 35W LED tube on tubular steel poles along with the boundary wall at a distance of 30 meter as per as per clause 16.0 of section 7 of the specification 44 c) Complete lighting of road and street by providing 90W LED lamps on tubular steel poles at a distance of 15meter along the roads and streets as per as per clause 16.0 of section 7 of the specification. 45 d) Supply and installation of post top lantern 40W LED Lamps with all complete accessories at the entrance gate of sub-station. 46 e) Supply and installation of 40W LED Lamps with all complete accessories on corners of control room building. 47 Complete Substation automation system of 66/11kV substation including hardware (along with transducers) and software along with associated equipment for the bays (bay as defined in the technical specification, sec-sub-station automation system) as per technical specification. Name of 66 kV BayPresent Future66 kV T/F Bay2 66 kV Line Bay 46*66 kV Bus Coupler Bay 1 * Provision shall be made in SAS to accomodate future scope (i.e. 6 No. 66 kV bays as per space available in GELO) alongwith present scope.Note: Signals from protection relays in 11 kV incomer would also be wired to substation automation system (SAS) 48 Time synchronization equipment 49 High wall type split AC unit2 Ton capacity for C&R Panel room and SCADA room: (as per technical specification). 50 Computer system (SFF) with: Intel core i5 processor with 11th generation or higher as specified in sectiion-04 51 Multi-Function Monochromatic Laser Jet Machine (A4-25 PPM or more) with print copy and scan function, Duplexing feature, composite cartridge, ADF, A4 or larger flatbed size, Networking and wi-fi both, at least 1 input tray, 3 years on site OEM warranty. 52 BOM FOR SAMAST COMPLIANT IEM (ON SEPARATE CUBICLE) FOR 11KV I/C: 1. (a) 3P4W Interface Energy Meters (ABT type) 0.2s Class 1A with TTB & BCS 53 1 (b) Testing of IEM System from NABL accredited lab 54 2. Wired Indoor Meters Panel suitable for 8 meters 55 3. 16 P Industrial Grade un-managed Network switch 56 4. (a) Data concentrator unit (DCU)/ communication Gateway (IG) with dual SIM Modem along with enclosure and accessories 57 4. (b) 3C x 2.5 Sq. mm Un-armoured cable for DCU and Switches 58 5. Cat-6 cable-unshielded 59 6. PVC conduit Pipe - 3/4 with accessories for Cat-6 cable 60 7. Armored Fibre Optic Cable (2 pair) 61 8. HDPE conduit - 40/33 with accessories 62 9. 4Cx4 Sqmm armoured cable for PT 63 10. 4Cx4 Sqmm armoured cable for CT 64 48V 120AH Battery Bank San Tubular 65 48V SMPS Battery Charger (for 48V 120AH Battery Bank San Tubular Battery) 66 For 66kV Substation HVPNL Chaurmastpur 1. The supply of Numerical Line Current Differential-cum- Back up Distance Protection Relay in place of existing Distance Protection Relay on the existing C&R panels (non-SAS compliant) installed at 66kV S/stn. HVPNL, Chaurmastpur (for 66 kV D/C Chaurmastpur - Sullar Lines)2. The erection/ retrofitting, testing & commissioning of Numerical Line Current Differential-cum- Back up Distance Protection Relay in place of existing Distance Protection Relay on the existing C&R panels (non-SAS compliant) above at sr. no. 40 (1) installed at 66kV S/stn. HVPNL, Chaurmastpur shall be the part of scope of successful bidder. 67 For 66kV Substation HVPNL Layalpur Basti 1. The supply of Numerical Line Current Differential-cum- Back up Distance Protection Relay in place of existing Distance Protection Relay on the existing C&R panels (non-SAS compliant) installed at 66kV S/stn. HVPNL, Layalpur Basti (for 66 kV D/C Layalpur Basti – Sullar Lines).2. The erection/ retrofitting, testing & commissioning of Numerical Line Current Differential-cum- Back up Distance Protection Relay in place of existing Distance Protection Relay on the existing C&R panels (non-SAS compliant) above at sr. no. 41 (1) installed at 66kV S/stn. HVPNL, Layalpur Basti (for 66 kV D/C Layalpur Basti – Sullar Lines) shall be the part of scope of successful bidder. 68 Bolted type 11kV tension string assembly with 3 numbers Anti FOG type disc insulators (E&M strength 9000 kg) per string with all hardware accessories including ball & socket connections and tension clamp sets suitable for twin tarantulla conductor. Alternatively the bidder may quote silicon polymer composite insulator string in place of Disc Insulators 69 66 kV Bolted type tension string assembly with 6 numbers Anti FOG type disc insulators (E&M strength 9000 kg) per string with all hardware accessories including ball & socket connection and tension clamp set suitable for single zebra conductor. Alternatively the bidder may quote silicon polymer composite insulator string in place of Disc Insulators 70 66 kV bolted type tension string assembly with 6 numbers Anti FOG type disc insulators (E&M strength 9000 kg) per string with all hardware accessories including ball & socket connections and suspension clamp set suitable for Twin zebra conductor. Alternatively the bidder may quote silicon polymer composite insulator string in place of Disc Insulators 71 66 kV bolted type suspension string assembly with 5 numbers Anti FOG type disc insulators (E&M strength 9000 kg) per string with all hardware accessories including ball & socket connections and suspension clamp set suitable for Singlezebra conductor. Alternatively the bidder may quote silicon polymer composite insulator string in place of Disc Insulators 72 66 kV bolted type suspension string assembly with 5 numbers Anti FOG type disc insulators (E&M strength 9000 kg) per string with all hardware accessories including ball & socket connections and suspension clamp set suitable for Twin zebra conductor. Alternatively the bidder may quote silicon polymer composite insulator string in place of Disc Insulators 73 Boltless C-Type Wedge connectors matching with conductor size. 74 Copper lugs glands, PVC ferrules for control cabling. 75 Fiber cleats, Aluminium clamps, bolts, nuts, washers etc., for fixing control cables in trenches. 76 Galvanized iron perforated tray with side coupler plate bolts, nuts, washers and clamps etc. of size 75x25x2 mm, 150x25x2mm, 100x25x2mm etc. & G.I. Conduits of 50mm/100mm dia from equipment to main trench as per Section-7, Switchyard erection. 77 ACSR Zebra Conductor 78 AAC Tarantulla Conductor 79 7/3.15 GS Earth wire 80 Spacers for Twin Tarantullaand Twin Zebra Conductor 81 U-bolt 20mm dia. 82 Mandatory spares for hardware/mechanical/Electrical auxiliaries to be supplied. 10 % of the finally approved quantities for item mentioned from Sr. No. 68 to 72. 83 2.5 ″ dia HDD/PVC pipe for 4c x 4 mm2 c/cable from CT, VT to maintaining system as per sec-5. 84 Item for associated structure workA)‘Lattice type steel structure for 66 kV AIS Sullar. Supply of material, preparation of fabrication drawing, galvanizing and delivery of lattice type steel structure for tower and beams for 66/11KV switchyard fabricated from steel conforming to IS: 2062 including nuts-bolts gusset plates foundation bolts and other accessories as per drawings supplied by the owner:Main S/Stn. tower and beam:a)Tower type CT-4 85 b) Tower type CT-5 86 c) Tower type CT-6 87 d) Tower type CT-8 88 e) Beam type CB-6 89 f) Beam type CB-7 90 g) Tower type DT-2 91 h) Tower type DT-3 92 i) Beam type DB-2X 93 B) Equipment Structure:a) 66 kV CT Drg. No. HTD/ST-88R 94 b) 66 kV NCT Drg. No. HTD/ST-145 (if required ) 95 c) 66 kV PT Drg. No. HHW/ST-66 96 d) 66 kV Surge Arrestor Drg. No. HTD/ST-89 97 e) 66 kV Isolator Drg. No. HTD/ST-87R 98 f) 66 kV L&E Switch Drg. HTD/ST-87R 99 g) 11 kV NCT Drg. HTD/ST-149 (if combined structure used) or 11 kV NCT Drg. HTD/ST-88R (if required). 100 EARTH WORK :Earth filling with good earth (as per satisfaction of Executive Engineer/Civil Works Division), laying in layers (as per specification), dressing, including carriage, irrespective of lead, loading, unloading, watering and compaction in layers with roller including compensation of earth complete in all respect. 101 2. FOUNDATIONS:Supply of labour, T&P, material and construction of RCC footings & pedestals etc. for steel gantry and equipment structures complete in all respects as per technical specifications & approved drawings including cost of excavation, concreting, cement, reinforcement steel, form work, grouting, holding down bolts, backfilling etc.and other items not mentioned herein but required for the completion of work.A. GANTRY TOWERS66kV sidei) CT-4 102 ii) CT-5 103 iii) CT-6 104 iv) CT-8 105 33kV sidei) DT-2 106 ii) DT-3 107 B. EQUIPMENT 66kV sidei) 66KV LA 108 ii) 66KV CVT/PT 109 iii) 66KV NCT 110 iv) 66kV CT 111 v) 66kV L&E & Isolator 112 11kV sidei) 11kV NCT 113 3. BREAKER FOUNDATIONDesign, engineering, supply of labour, material, equipment & const. of foundations for breaker including all associated works PCC, RCC, structural steel, steel reinforcement & any other item not specifically mentioned herein but reqd. for completion of work as per tech. spec.i) 66 kV Breaker Foundation 114 4. CAPACITOR BANK FOUNDATIONSDesign, Engg. & supply of labour, material & construction of foundations for following rating capacitor bank with capacitor unit (with allied equipments) & series Reactor etc. including chain link fencing 1.8M height around cap. bank complete in all respect including any other items not specifically mentioned herein but required for completion of job as per technical specification.i) 9000KVAR 12.65 kV Capacitor Bank 115 5. TRANSFORMER FOUNDATION5.1 Design, Engg., supply of labour, material and construction of foundation for station transformer including all associated works, RCC, PCC, Reinforcement steel, misc. structural steel and other items not mentioned herein but required for the completion of work as per technical specifications.i) 11/0.4kV 200KVA Station T/F 116 5.2 Construction of transformer foundation including all associated works, RCC, PCC, reinforcement steel, misc. structural steel and other items not mentioned herein but required for completion of work as per technical specifications & approved drgs. In case extra foundation(s) has/have to be constructed (as per approved T/F drawing) to complete the job, nothing extra would be paid on this count.i) 25/31.5 MVA 66/11 kV T/F Foundation 117 6. CABLE TRENCHESSupply of labour, material such as cement, reinforcement steel, GI angles, flats, PCC & brick pillars below cable trenches for construction of Out-Door Cable Trenches (ODCT) of required depth/ type with pre-cast RCC covers including associated works like Cable Trench Culverts,crossings for roads and sump- pit-cum-pump chamber with 2HP motor of reputed make, starter, volt meter, amp-meter etc. as per foundation & trench layout plan attached, HVPNL drgs. & tech. specs. complete in all respect. i) D-type trench 118 ii) E-type trench 119 iii) G-type trench 120 iv) H-type Trench 121 v) GI Pipe 122 vi) Sump Pit Cum Pump Chamber 123 7. SITE SURFACING7.1 Providing, supplying & laying 100mm thick PCC (1:4:8) using 20mm nominal coarse aggregates and supplying & spreading 100mm thick layer of 40mm nominal size uncrushed/ crushed/broken stone pebbles over the PCC including construction of toe wall (exposed wall plastered with cement mortar 1:5) to hold 40mm single size uncrushed/ crushed /broken stone pebbles wherever required in the bays covered under the present scope as detailed in the GELO & instructions of engineer incharge. 124 7.2 Providing, supplying & laying 100mm thick in two layers of 50mm each of 20mm nominal size uncrushed/crushed/ broken stone pebbles gravel fill including dressing, rolling & compacting complete in all respects as per specs. & instructions of engineer incharge. 125 8. ROADS & PCC PAVEMENT8.1 Supply of labour, material and construction of cement concrete roads and walkways/shoulders from NH/SH/etc. to Switch yard/Switch house building as per GELO/CLO as per sectional detail drawing no. HCD/SK-181 R1 and technical specification.i) 6.0M wide road (Near main gate of substation) 126 ii) 3.66m wide road within substation land 127 iii) PCC in front and rear of parking area of SH Building as per tech. specification and drawing HCD/SK-172. 128 9. ROAD CULVERTSDesign Engineering and construction of Pipe culvert(s) at suitable locations under the approach road (from main PWD/ HUDA/Municipal/Village road to the sub-station entry point) including, cost of labour, material complete in all respects as per I.R.C. Standards. 129 10. BOUNDARY WALL10.1 Supply of labour, material and construction of front, C & U/C boundary walls including main gate foundations as per GELO/CLO, technical specifications. & HVPNL drg. HCD/TS-1176 R3 including excavation backfilling, lean & DPC complete in all respect.i) 6 ft. high with GI barbed wire on angles at top. 130 ii) 4½ ft. high front wall including providing grill at top of wall & construction of main entrance gate (with wicket gate). 131 iii) 4½ ft. side wall with GI barbed wire 132 10.2 Supply of labour, T&P, material and construction of front, side & U/C boundary walls including main gate(s) (brickwork below DPC level) as per GELO/CLO, tech. spec. & HVPNL drawings complete in all respects. 133 11. U/C FENCING & GATESProviding & fixing chain link fencing including foundations, GI angle iron posts and gate(s) complete as per electrical layout & tech. spec. & as per drawing attached. 134 12. DRAINAGE–CUM-RAIN HARVESTING SYSTEMThe successful bidder shall evolve design & drawing for drains, manholes with RCC covers andsettlement tankincluding preparation of drainage layout drawing for disposal of rain water from building’s roof top & switch yard (s/stn.) area into respective bore well(s) in such a way that there shall be no ponding of water on the roof and switch yard (s/stn.). The layout so developed shall be got approved from the employer. The location of sump-pit-cum-pump chamber shall preferably be locatedon corner(s) of the s/stn. and shall be got decided from the concerned XEN/Civil Works Division on the basis of surroundings of the substation(s). The successful bidder will also supply labour and material for construction of sump-pit-cum-pump chamber as per HVPNL drgs. & provide one no. non clog pump(s) of 5HP of reputed make capacity with main switch, starter, volt meter, Amp. Mtr. etc. (for each sump pit) for disposal of excess water to outfall point. Any other item(s) not mentioned herein but is/are required for completion of works shall be done by the successful bidder without any extra cost to the employer.i) Drain Section-1 135 ii) Drain Section-2 136 iii) Drain Section-3 137 iv) Road Crossing 138 v) Trench Crossing 139 vi) Sump Pit Cum Pump Chamber 140 13. CONTROL ROOM BUILDINGSupply of labour, material, T&P and construction of control room building complete in all respect as per tech. specs. including exterior weather proof paint, interior emulsion, all internal services like water supply including supply & providing of 5000ltr. capacity double layer Sintex/Diplast PVC tank, Sewerage system, electrification including wiring, modular switches, maximum 20W 4ft. long LED tubes with fittings minimum 1960 lumens, ceiling/exhaust fans, Finishing, Plinth protection, RCC flooring, Indoor trenches, Soakage pit near the switch house building, connection of sewerage system to Soakage pit/Sewerage system of local authorities (as applicable), connection to main water supply system of local authority, bore (Tubewell) (as applicable) etc. & any other item not mentioned herein but required for completion of works. 141 14. RCC M-20 inclusive of labour, material, shuttering, Steel reinforcement etc. complete in all respects to compensate excess quantity required to be executed due to difference in existing ground level and the formation level to be fixed after contouring or difference on account of revised drg issued at the time of construction and the tender drg.
Contract Date : Ref. Documents   |   Contract Value : Ref. Documents
BRR : 9231097 Construction Of 66 Kv Ais Substation Mussimble, Yamuna Nagar With 2X25/31.5 Mva 66/11 Kv Power T/Fs And 66 Kv Ais Substation Sadopur, Ambala With 2 X 25/31.5 Mva 66/11 Kv T/Fs On Turnkey Basis-- 1 25/31.5 MVA 66/11 kV T/Fs 2 66 kV SF-6 Breaker along with 20% extra SF-6 Gas 3 66 kV Isolator with E/Switch 4 66 kV Isolator without E/Switch 5 66 kV Surge Arrestor 6 66 kV CTs for Line & Bus Coupler (600-300-150/1-1-1A) 7 66 kV T/F CT (300-200-150/0.577-1-1A) 8 66 kV PT for line 9 66 kV NCT (300-200-150/1A) 10 11 kV NCT (1800-900/5A) 11 11 kV LA 12 11 kV 15 Panel Board 2000A (including one no. bus sectionalizer panel) 13 66kV C&R Panels with SAS:a) Bus Coupler Protection and Circuit Breaker Panel (Without Auto Reclose)with SAS compliant 14 b) Line Protection and Circuit Breaker Panel (Without Auto Reclose) with SAS 15 c) Line Protection and Circuit Breaker Panel without Auto Reclose (SAS Compliant) with Line Current Differential-cum-Distance Protection Relay (for 66 kV D/C Dhulkote-Sadopur Lines) 16 d) Line Protection and Circuit Breaker Panel without Auto Reclose (SAS Compliant) with Distance Protection Relay (for 66 kV S/C Layalpur Basti-Sadopur Lines) 17 e) Transformer Protection and Circuit Breaker Panel (Without Auto Reclose)with SAS compliant 18 9000 KVAR 12.65 kV Automatically Switched Capacitor Bank along with allied equipments as per technical specification. 19 220V 100AH Battery San Tubular 20 220 V 20/30A Battery charger (SMPS) 21 220V D.C.D.B. 22 415 V LT AC Distribution Board 300 A 23 11/0.4 kV Station T/F 200 KVA 24 (a) 1.1 kV Copper Control Cable unarmoured for 66kV bays of size 7Cx4mm2, 4Cx4mm2, 2Cx4mm2, 2Cx6mm2, 3Cx2.5mm2, 16Cx2.5mm2, 10Cx2.5mm2 & 7Cx2.5mm2 including junction box etc. refer Section-5 of copper & control cable & Section-7 for switchyard erection 25 (b) Stainless steel MK (200 TB) 26 a) 11 kV Aluminium Power Cable XLPE 1C x1000mm2 for T/F to 11kV incomer (4 runs per phase for each transformerallocating them 2 runs per phase for each 11kV I/C) 27 b) Termination kit at both ends for 11kV XLPE power Cable (1C x 1000mm2) Termination Kits for (Indoor/Outdoor) both ends along with accessories constitute a set for each cable. 28 a) 11 kV Aluminium Power Cable XLPE 3C x 400sq mm for Capacitor Bank 29 b) Termination kit at both ends for 11kV XLPE power Cable (3C x 400mm2) Termination Kits for (Indoor/Outdoor) both ends along with accessories constitute a set for each cable. 30 a) 11 kV Aluminium Power Cable XLPE 3C x 50 sq. mm for station T/F 31 b) Termination kit at both ends for 11kV XLPE power Cable (3C x 50mm2) Termination Kits for (Indoor/Outdoor) both ends along with accessories constitute a set for each cable. 32 650/1100 Volts 3.5 core 240 mm2 aluminium power cable from Aux. T/F to ACDB. 33 650/1100 Volt 3.5 core 70 mm2 aluminium cable for oil filtration set. 34 650/1100 Volt 4core 16mm2 unarmoured with copper power cable for MLDB and other cable required as per contract for 66kV bays. 35 Earthing Mat Material. The earth mat will be designed/quoted for soil resistivity of 50Ωm. In case soil resistivity is more than 50Ωm then the earth mat will be designed for actual soil resistivity. The payment of extra material to be used for earth mat shall be made on pro rata basis. The approximate area of earth mat to be laid is given in the corresponding columns of the substations. However, item will remain a Lot item (calculations may be made considering fault/shock duration of 1 sec).(7400 sq. meter for Mussimble & 5900 sq. meter for Sadopur) 36 Fire Fighting equipments as per section-6:i) 22.5 Kg Capacity FE CO2 type, Trolley Mounted 37 ii) 25 Kg Capacity FE DCP type, Trolley Mounted 38 iii) DCP 10 Kg Capacity, Wall mounted 39 iv) FE CO2 6.5 Kg Capacity, Wall mounted 40 v) DCP 5 Kg Capacity, Wall mounted 41 vi) Foam Type 9 Litre Capacity, Wall mounted 42 vii) Water CO2 9 Litre, Wall mounted 43 viii) Fire Buckets (12 Nos. with stand in one set) 44 Complete lightning of control room building, switch yard area, road and street as per section-7 of the specification:a) Supply and installation of 2 fittings of 240W LED lamps with all accessories for Complete lighting of outdoor Switch yard area as per clause 16.0 of section 7 of the specifications. 45 b) Supply and installation of 35W LED tube on tubular steel poles along with the boundary wall at a distance of 30 meter as per as per clause 16.0 of section 7 of the specification 46 c) Complete lighting of road and street by providing 90W LED lamps on tubular steel poles at a distance of 15meter along the roads and streets as per as per clause 16.0 of section 7 of the specification. 47 d) Supply and installation of post top lantern 40W LED Lamps with all complete accessories at the entrance gate of sub-station. 48 e) Supply and installation of 40W LED Lamps with all complete accessories on corners of control room building. 49 Complete Substation automation system of 66/11kV substations including hardware (along with transducers) & software along with associated equipment for the bays (bay as defined in the technical specification, sec-substation automation system) as per technical specification.66 kV Mussimble Present FutureSr. No.DescriptionNo. of 66 kV Bays1. T/F2 12.Line 223. B/C 1-66kV SadopurNo. of 66 kV Bays Sr. No.DescriptionPresent Future1. T/F 2 6*2.Line3 3. B/C 1 * As per space available in GELO. Accordingly, provision shall be made in SAS to accommodate future scope along with present scope. Note: signals from protection relays in 11 kV incomer would also be wired to substation automation system (SAS) 50 Time synchronization equipment 51 High wall type split AC unit of 2 Ton capacity for SCADA room & C&R Panel room (as per technical specification). 52 Computer system (SFF) with: Intel core i5 processor with 11th generation or higher as specified in Section-04 53 Multi-Function Monochromatic Laser Jet Machine (A4-25 PPM or more) with print copy and scan function, Duplexing feature, composite cartridge, ADF, A4 or larger flatbed size, Networking and wi-fi both, at least 1 input tray, 3 years on site OEM warranty 54 BOM FOR SAMAST COMPLIANT IEM (ON SEPARATE CUBICLE) FOR 11KV I/C:1 (a) 3P4W Interface Energy Meters (ABT Type) 0.2s Class 1A with TTB & BCS (2 No. for each 11 kV Incomer) 55 1 (b) Testing of IEM System from NABL accredited lab 56 2. Wired Indoor Meters Panel suitable for 8 meters 57 3. 16 P Industrial Grade un-managed Network switch 58 4 (a) Data concentrator unit (DCU)/communication Gateway (IG) with dual SIM Modern alongwith enclosure and accessories 59 4 (b) 3C x 2.5 sq. mm Un-armoured cable for DCU and Switches 60 5. Cat-6 cable-unshielded 61 6. PVC conduit pipe-3/4 with accessories for Cat-6 cable (In line with cat-6 cable) 62 7. Armored Fibre Optic Cable (2 pair) 63 8. HDPE conduit - 40/33 with accessories (In line with armored cable for CT/PT) 64 9. 4Cx4 Sqmm armoured cable for PT 65 10.4Cx4 Sqmm armoured cable for CT 66 48V 120AH Battery Bank San Tubular 67 48V SMPS Battery Charger (for 48 V 120 AH Battery Bank San Tubular Battery) 68 For 220 kV Substation, BBMB, Dhulkote: 1. The supply of Numerical Line Current Differential-cum- Back up Distance Protection Relay for C&R Panels (non-SAS compliant)installed at 220 kV Substation, BBMB, Dhulkote (for 66 kV D/C Dhulkote - Saddopur Lines). 69 2. The erection/ retrofitting, testing & commissioning of Numerical Line Current Differential-cum- Back up Distance Protection Relay in place of existing Distance Protection Relay on the existing C&R Panels (non-SAS compliant) above at sr. no. 68 installed at 220 kV Substation, BBMB, Dhulkote (for 66 kV D/C Dhulkote - Saddopur Lines) shall be the part of scope of successful bidder. 70 Bolted type 11kV tension string assembly with 3 numbers Anti FOG type disc insulators (E&M strength 9000 kg) per string with all hardware accessories including ball & socket connections and tension clamp sets suitable for twin tarantulla conductor. Alternatively the bidder may quote silicon polymer composite insulator string in place of Disc Insulators 71 66 kV Bolted type tension string assembly with 6 numbers Anti FOG type disc insulators (E&M strength 9000 kg) per string with all hardware accessories including ball & socket connection and tension clamp set suitable for single zebra conductor. Alternatively the bidder may quote silicon polymer composite insulator string in place of Disc Insulators 72 66 kV Bolted type tension string assembly with 6 numbers Anti FOG type disc insulators (E&M strength 9000 kg) per string with all hardware accessories including ball & socket connection and tension clamp set suitable for twin zebra conductor. Alternatively the bidder may quote silicon polymer composite insulator string in place of Disc Insulators 73 66 kV bolted type suspension string assembly with 5 numbers Anti FOG type disc insulators (E&M strength 9000 kg) per string with all hardware accessories including ball & socket connections and suspension clamp set suitable for single zebra conductor. Alternatively the bidder may quote silicon polymer composite insulator string in place of Disc Insulators 74 66 kV bolted type suspension string assembly with 5 numbers Anti FOG type disc insulators (E&M strength 9000 kg) per string with all hardware accessories including ball & socket connections and suspension clamp set suitable for twin zebra conductor. Alternatively the bidder may quote silicon polymer composite insulator string in place of Disc Insulators 75 Boltless C-Type Wedge connectors matching with conductor size. 76 Copper lugs glands, PVC ferrules for control cabling. 77 Fiber cleats, Aluminium clamps, bolts, nuts, washers etc., for fixing control cables in trenches. 78 Galvanized iron perforated tray with side coupler plate bolts, nuts, washers and clamps etc. of size 75x25x2 mm, 150x25x2mm, 100x25x2mm etc. & G.I. Conduits of 50mm/100mm dia from equipment to main trench as per Section-7, Switchyard erection. 79 ACSR Zebra Conductor (approx.) 80 AAC Twin Tarantulla Conductor (approx.) 81 7/3.15 GS Earth wire 82 Spacers for TwinTarantulla/ZebraConductor 83 U-bolt 20mm dia. 84 Mandatory spares for hardware/mechanical/Electrical auxiliaries to be supplied. 10 % of the finally approved quantities for item mentioned from Sr. No. 70 to 74. 85 2.5 ″ dia HDD/PVC pipe for 4c x 4 mm2 c/cable from CT, VT to maintaining system as per sec-5, chapter-5. 86 Item for associated structure workA)‘‘Lattice type steel structure for 66kV AIS Mussimble (Yamuna Nagar) & Sadopur (Ambala), Supply of material, preparation of fabrication drawing, galvanizing and delivery of lattice type steel structure for tower and beams for 66/11KV switchyard fabricated from steel conforming to IS: 2062 including nuts-bolts gusset plates foundation bolts and other accessories as per drawings supplied by the owner.66kV Cable support structure of galvanized iron along with foundation to be designed by bidder as per site requirement/size of cableMain S/Stn. tower and beam:a)Tower type CT-4 87 b) Tower type CT-5 88 c) Tower type CT-6 89 d) Tower type CT-8 90 e) Beam type CB-6 91 f) Beam type CB-7 92 g) Tower type DT-2 93 h) Tower type DT-3 94 i) Beam type DB-2X 95 B) Equipment Structure:a) 66 kV CT Drg. No. HTD/ST-88R 96 b) 66 kV NCT Drg. No. HTD/ST-145 (if required ) 97 c) 66 kV PT Drg. No. HHW/ST-66 98 d) 66 kV Surge Arrestor Drg. No. HTD/ST-89 99 e) 66 kV Isolator Drg. No. HTD/ST-87R 100 f) 66 kV L&E Switch Drg. HTD/ST-87R 101 g) 11 kV NCT Drg. HTD/ST-149 (if combined structure used) or 11 kV NCT Drg. HTD/ST-88R (if required). 102 1. EARTH WORK 1.1 Earth filling with good earth (as per satisfaction of Executive Engineer/Civil Works Division), laying in layers (as per specification), dressing, including carriage, irrespective of lead, loading, unloading, watering and compaction in layers with roller including compensation of earth complete in all respect. 103 1.2 DewateringDewatering of subsoil water for lowering of water table to enable excavation of earth, concreting for all type of works and backfilling, by boring of tube wells or deploying well point system so that continuous lowering of water table is made till completion of work, without disturbing the soil characteristics. The rate shall include all type of expenditure for required dewatering arrangements. 104 2. FOUNDATIONSWORK FOR 66 KV MUSSIMBLE:Supply of labour, T&P, material and construction of RCC footings & pedestals etc. for steel gantry and equipment structures complete in all respects as per HVPNL standard drawing, technical specifications including cost of excavation, concreting, cement, reinforcement steel, form work, grouting, holding down bolts, backfilling etc.and other items not mentioned herein but required for the completion of work.A. GANTRY TOWERS i) CT-4 105 ii) CT-5 106 iii) CT-6 107 iv) CT-8 108 v) DT-2 109 vi) DT-3 110 B. EQUIPMENT 66kV sidei) 66KV LA 111 ii) 66KV CVT/PT 112 iii) 66KV CT 113 iv) 66kV L&E & Isolator 114 v)66kV NCT 115 11kV sidei) 11kV NCT 116 3. FOUNDATIONS WORK FOR 66 KV SADOPUR:Design engineering & supply of labour, T&P, material and construction of RCC footings & pedestals etc. for steel gantry and equipment structures complete in all respects as per technical specifications & approved drawings including cost of excavation, concreting, cement, reinforcement steel, form work, grouting, holding down bolts, backfilling etc.and other items not mentioned herein but required for the completion of work.The successful bidder shall develop the designs & drawings as per the soil investigation report attached in specification and shall get these checked/vetted from any professsional institute as per contract before final approval.A. GANTRY TOWERS i) CT-4 117 ii) CT-5 118 iii) CT-6 119 iv) CT-8 120 v) DT-2 121 vi) DT-3 122 B. EQUIPMENT 66kV sidei) 66KV LA 123 ii) 66KV CVT/PT 124 iii) 66KV CT 125 iv) 66kV L&E & Isolator 126 v)66kV NCT 127 11kV sidei) 11kV NCT 128 4. BREAKER FOUNDATIONDesign, engineering, supply of labour, material, equipment & const. of foundations for breaker including all associated works PCC, RCC, structural steel, steel reinforcement & any other item not specifically mentioned herein but reqd. for completion of work as per tech. spec.i) 66 kV Breaker Foundation 129 5. RoadsSupply of labour, material and construction of cement concrete roads and walkways/shoulders from NH/SH/etc. to Switch yard/Switch house building as per GELO/CLO as per sectional detail drawing no. HCD/SK-181 R1 and technical specification.i. 6.0m wide road (Near main gate of substation) 130 ii. 3.66 wide road 131 6. CAPACITOR BANK FOUNDATIONSDesign, Engg. & supply of labour, material & construction of foundations for capacitor bank with capacitor unit (with allied equipments) & series Reactor etc. including chain link fencing 1.8M height around cap. bank complete in all respect including any other items not specifically mentioned herein but required for completion of job as per technical specification.i) 9000 KVAR 12.65 kV capacitor bank 132 7. ROAD CULVERTDesign, Engineering and const. of Pipe culvert(s) at suitable locations under the approach road (from main PWD/ HUDA/Municipal/Village road to the sub-station entry point) including, cost of labour, material complete in all respects as per I.R.C. Standards. 133 8. TRANSFORMER FOUNDATION FOR 66 KV MUSSIMBLE : 8.1 Construction of transformer foundation including all associated works, RCC, PCC, reinforcement steel, misc. structural steel and other items not mentioned herein but required for completion of work as per technical specifications & approved drgs. In case extra foundation(s) has/have to be constructed (as per approved T/F drawing) to complete the job, nothing extra would be paid on this count..25/31.5MVA,66/11kV T/F foundationcomplete in all respect. 134 9. TRANSFORMER FOUNDATIONWORK FOR 66 KV SADOPUR: 9.1 Design Engineering & construction of transformer foundation including all associated works, RCC, PCC, reinforcement steel, misc. structural steel and other items not mentioned herein but required for completion of work as per technical specifications & approved drgs. In case extra foundation(s) has/have to be constructed (as per approved T/F drawing) to complete the job, nothing extra would be paid on this count.The successful bidder shall develop the designs & drawings as per the soil investigation report attached in specification and shall get these checked/vetted from any professsional institute as per contract before final approval..25/31.5MVA,66/11kV T/F foundationcomplete in all respect. 135 10 Statipon Transformer Foundation work: Design, Engg., supply of labour, material and construction of foundation for station transformer including all associated works, RCC, PCC, Reinforcement steel, misc. structural steel and other items not mentioned herein but required for the completion of work as per technical specifications.11/0.4kV 200KVA Station T/F 136 11. OUTDOOR CABLE TRENCHES:Supply of labour, material such as cement, reinforcement steel, GI angles, flats, PCC & brick pillars below cable trenches for construction of Out-Door Cable Trenches (ODCT) of required depth/ type with pre-cast RCC covers including associated works like Cable Trench Culverts crossings for roads and sumpit-cum-pump chamber with 2HP motor of reputed make, starter, volt meter, amp-meter etc. as per approved trench layout plan, HVPNL drgs. & tech. specs. complete in all respecti) D-type trench 137 ii) E-type trench 138 iii) F-type trench 139 iv) G-type trench 140 v) H-type trench 141 vi) Road culvert 142 vii) Sump Pit Cum Pump Chamber 143 12. SITE SURFACING:12.1Providing, supplying & laying 100mm thick in two layers of 50mm each of 20mm nominal size uncrushed/crushed/ broken stone pebbles gravel fill including dressing, rolling & compacting complete in all respects as per specs. & instructions of engineer incharge. 144 12.2 Providing, supplying & laying 100mm thick PCC (1:4:8) using 20mm nominal coarse aggregates and supplying & spreading 100mm thick layer of 40mm nominal size uncrushed/ crushed/broken stone pebbles over the PCC including construction of toe wall (exposed wall plastered with cement mortar 1:5) to hold 40mm single size uncrushed/ crushed /broken stone pebbles wherever required in the bays covered under the present scope as detailed in the GELO & instructions of engineer incharge. 145 13. BOUNDARY WALL13.1 Supply of labour, T&P, material & construction of front, side & U/C boundarybelow DPC level as per GELO/CLO, tech. spec. & HVPNL drgs including excavation, PCC, brickwork, back filling, plaster, painting etc. complete in all respects. 146 13.2 Supply of labour, material and construction of front, C & U/C boundary walls above DPC including main gate foundationsas per GELO/CLO, technical specifications. & HVPNL drg. HCD/TS-1176 R3 including DPC complete in all respect.i. 6 ft. high U/C B/wall with barbed wire on angles at top. 147 ii. 4½ ft. high front wall including providing grill at top of wall & construction of gate pillars. 148 iii. 4½ ft. high side wall with barbed wire on angles at top of wall. 149 14. CONTROL ROOM BUILDING FOR 66 KV MUSSIMBLE: Supply of labour, material, T&P and construction of control room building complete in all respect as per tech. specs. including exterior weather proof paint, interior emulsion, all internal services like water supply including supply & providing of 5000ltr. capacity double layer Sintex/Diplast PVC tank, Sewerage system, electrification including wiring, modular switches, maximum 20W 4ft. long LED tubes with fittings minimum 1960 lumens, ceiling/exhaust fans, Finishing, Plinth protection, flooring, Indoor trenches, Soakage pit near the switch house building, Rcc pipe around the building to drain of water,connection of sewerage system to Soakage pit/Sewerage system of local authorities (as applicable), connection to main water supply system of local authority, bore (Tubewell) (as applicable) etc. & any other item not mentioned herein but required for completion of works. 150 15. CONTROL ROOM BUILDING FOR 66 KV SADOPUR:The design of foundation below plinth level is in the scope of successful bidder. However, the architectural design and the structural design above plinth level shall be kept same as per HVPNL standard drawings attached with bidding documents. Design engineering, supply of labour, material, T&P and construction of control room building complete in all respect as per tech. specs. including exterior weather proof paint, interior emulsion, all internal services like water supply including supply & providing of 5000ltr. capacity double layer Sintex/Diplast PVC tank, Sewerage system, electrification including wiring, modular switches, maximum 20W 4ft. long LED tubes with fittings minimum 1960 lumens, ceiling/exhaust fans, Finishing, Plinth protection, flooring, Indoor trenches, Soakage pit near the switch house building, connection of sewerage system to Soakage pit/Sewerage system of local authorities (as applicable), connection to main water supply system of local authority, bore (Tubewell) (as applicable) etc. & any other item not mentioned herein but required for completion of works.The successful bidder shall develop the designs & drawings as per the soil investigation report attached in specification and shall get these checked/vetted from any professsional institute as per contract before final approval. 151 16. U/C FENCING & GATESProviding & fixing chain link fencing including foundations, GI angle iron posts and gate(s) complete as per electrical layout & tech. spec. & as per drawing attached. 152 17. PCC PAVEMENTConstruction of PCC pavement in front, rear or side (as per site requirement of the switch house building) as per drawing no. HCD/SK-172 & technical specifications. 153 18. DRAINAGE–CUM-RAIN HARVESTING SYSTEM for 66 kV substation Mussimble 18.1 Supply of labour, material for construction ofrecharge structures with bore well(s) as per HVPN drawings & specs. complete in all respect . The location of recharge structures shall preferably be located on corner(s) of the substation and shall be got decided from the concerned Engineer in-Charge on the basis of surroundings of the substation(s). In case ground water table is less than 8m from FGL, rain harvesting well shall not be constructed (the drainage system with sump pit is to be constructed as per item mentioned below). 154 18.2 The successful bidder shall evolve design & drawing for drains, manholes with RCC covers andsettlement tankincluding preparation of drainage layout drawing for disposal of rain water from building’s roof top & switch yard (s/stn.) area into respective bore well(s) in such a way that there shall be no ponding of water on the roof and switch yard (s/stn.). The layout so developed shall be got approved from the employer. The location of sump-pit-cum-pump chamber shall preferably be locatedon corner(s) of the s/stn. and shall be got decided from the concerned Engineer in-Charge on the basis of surroundings of the substation(s). The successful bidder will also supply labour and material for construction of sump-pit-cum-pump chamber as per HVPNL drgs. & provide one no. non clog pump(s) of 5HP of reputed make capacity with main switch, starter, volt meter, Amp. Mtr. etc. (for each sump pit) for disposal of excess water to outfall point. Any other item(s) not mentioned herein but is/are required for completion of works shall be done by the successful bidder without any extra cost to the employer.i)Drain Section-1 155 ii) Drain Section-2 156 iii) Drain Section-3 157 iv) Road Crossing 158 v) Trench Crossing 159 vi) Sump Pit Cum Pump Chamber 160 19. DRAINAGE–CUM-RAIN HARVESTING SYSTEM for 66 kV substation Sadopur The successful bidder shall evolve design & drawing for drains, manholes with RCC covers andsettlement tankincluding preparation of drainage layout drawing for disposal of rain water from building’s roof top & switch yard (s/stn.) area into respective bore well(s) in such a way that there shall be no ponding of water on the roof and switch yard (s/stn.). The layout so developed shall be got approved from the employer. The location of sump-pit-cum-pump chamber shall preferably be locatedon corner(s) of the s/stn. and shall be got decided from the concerned Engineer in-Charge on the basis of surroundings of the substation(s). The successful bidder will also supply labour and material for construction of sump-pit-cum-pump chamber as per HVPNL drgs. & provide one no. non clog pump(s) of 5HP of reputed make capacity with main switch, starter, volt meter, Amp. Mtr. etc. (for each sump pit) for disposal of excess water to outfall point. Any other item(s) not mentioned herein but is/are required for completion of works shall be done by the successful bidder without any extra cost to the employer.The successful bidder shall develop the designs & drawings and shall get these checked/vetted from any professsional institute as per contract before final approval.i)Drain Section-1 161 ii) Drain Section-2 162 iii) Drain Section-3 163 iv) Road Crossing 164 v) Trench Crossing 165 vi) Sump Pit Cum Pump Chamber 166 20. RCC M-20 for 66 kV substation Mussimble inclusive of labour, material, shuttering, steel reinforcement etc. complete in all respects to compensate excess quantity required to be executed due to difference in existing ground level and the formation level to be fixed after contouring or difference on account of revised drawing issued at the time of construction and the tender drawing. 167 21. RCC Retaining wall for 66 kV substation Sadopur Design engineering, supply of labour, material and construction of T/L shaped RCC retaining wall below DPC to retain the earth filling complete in all respect. The successful bidder shall develop the designs & drawings as per the soil investigation report attached in specification and shall get these checked/vetted from any professsional institute as per contract before final approval.Difference between NGL & FGL from 2.5 to 3.5 mtr. 168 22. Distamtlement for 66 kV substation Sadopur :-Dismantling of existing residential quarters, OHT and underground tank etc. Dismantling including foundations of following structure. The material whatsoever shall be the property of the successful bidder. The dismantled material shall not be allowed for reuse at any of the sub-stations; however, HVPNL may allow use of bricks for brick ballast purpose only.Dismantling of existing residential quarters, Overhead tank, toilet, boundary wall and underground tank etc complete in all respect.
Contract Date : Ref. Documents   |   Contract Value : Ref. Documents
BRR : 10591948 tender for WORK OF REPLACEMENT OF EXISTING 100 MVA 220 / 132 KV TRANSFORMER (EMCO MAKE) WITH NEW 160 MVA 220 / 132 KV TRANSFORMER (TAL MAKE) AND OTHER ASSOCIATED WORKS AT 220 K.V. SUB STATION KURSI ROAD UNDER E.T.D. - II, LUCKNOW Sl. No. Item Description 1 Following Works are to be carried out at 220 K.V. Sub Station Kursi Road, Lucknow for replacement of existing 100 MVA 220 / 132 KV Transformer (EMCO make) by new 160 MVA 220 / 132 KV Transformer (TAL make) alongwith associated works against Increasing Capacity including all cost of men, T&P, Crane, 6 - 12 KL / Hr. capacity Centrifuging Machine with Operator, Carriage Vehicle etc. to complete the job satisfactorily as per direction of site Engineer : 2 Draining of Oil from 100 MVA EMCO make Transformer at 220 KV Sub Station Kursi Road into 209 Liter Capacity Oil Drums. 3 Dismantling of existing 120 KV LAs alongwith associated structures instailed in 100 MVA 220/132 KV Transformer Bay after due cutting of earthing, opening of jumpers etc. (1 Job per L.A. with structure). 4 Complete dismantling of all the water & air pipe lines, pipe supports etc. of Emulsifire Systern around the 100 MVA 220/132KV Transformer alongwith Shifting & Stacking of all the dismantled items at safe storage place at the Sub Station. 5 Opening of HV & LV side Jumpers, Removal of Neutral & Main Tank Earthing, Opening of Control / Power Cable Connections of 100 MVA 220/132 KV Transformer including opening of connections of associated OLTC & Marshalling Box. 6 Complete safe Dismantling of the accessories of 100 MVA 220/132 KV Transformer including opening of Jumpers, removal of earthing, opening of Cable connections, Removal of Conservator Tank, Pipe Lines, Bushings, Cooling Fans & Pumps, Marshaling Box, Radiators after Draining of Radiator Oil in empty Drums then fixing of blanking plates on the radiators, pipe lines, conservator tank turret etc. (Suitable Blanking Plate including Bolts & Nuts as required if not available at substation, shall be provided/arranged by the Contractor.) 7 Safe Shifting & proper Stacking at storage place of all the dismantled accessories of 100 MVA 220/132 KV Transformer i.e. Conservator Tank, Pipe Lines, Bushings, Cooling Fans & Pumps, Marshaling Box, Radiators, Headers, A Frame etc. and T/F Oil Drums at the safe storage place at the Sub Station. 8 Proper packing of HV/LV neutral bushings of the dismantled 100 MVA 220/132 KV Transformer in separate wooden cases / crates of the bushings after proper wrapping of bushing with polythene sheet alongwith reparing of wooden cases, to be provided by contractor. 9 (A) Shifting of Main Tank of the dismantled 100 MVA (EMCO make) 220/132 KV Transformer from the Plinth up to 20 Meter distance including turning of Tank, as required. 10 (B) Additional Shifting of the tank of above transformer upto 200 Meter distance. (01 Job for every 5 Meter and / or part there of) 11 Dismantling and shifting of existing 100 MVA TF RTCC panel from ACDB room including opening connection of control cables , identifying cables for future connection & shifting RTCC panel at place of storage as per instructions of supervising engineer (SDO/JE) 12 (A) Shifting of Main Tank of the new 160 MVA (TAL make) 220/132 KV Transformer to its Plinth from Place of Unloading up to 20 Meter distance including turning of Tank, as required. 13 (B) Additional Shifting of the tank of above transformer upto 120 Meter distance. (01 Job for every 5 Meter and / or part there of) 14 Complete erection of the 160 MVA (TAL make) Transformer including its radiators, conservator tank, turrets, connecting pipe lines, HV / HV / neutral bushings, cooling fans, OLTC drive mechanism box, marshalling box, OTI, WTI, capillary tubes etc. 15 Supply of dry Nitrogen gas having DEW point (-60°C to -65°C) under vacuum fro top valve of the transformer upto pressure of 2PSI (as per tehcnical norms of Transformer) and maintaning the same in the main tank for 12 Hrs. including cost of nitrogen gas and nitrogen gas filling device for dry cycle. 16 Create the vacuum inside the T/F tank & maintain it for 24 Hrs. dry air cycle of T/F creating vacuum inside the main tank of T/F, maintaning it for 24 Hrs. then filling of dry air bearing dew point (-60°C to -65°C) for 24 Hrs. And repeating the same till the PPM value of main tank is achieved below 05 PPM filling the oil step by step in 160 MVA T/F. 17 Centrifuging of completed T/F oil in T/F oil tank by connecting centrifuging machine to be provided by the contractor and taking the BDV,PPM & IR values of the oil & TF bushings periodically till the required value in achieved as per direction of Supervising Engineer (Centrifuging machine, BDV & PPM machine, megger shall be arranged by the contractor). After centrifuging ,DGA test of oil sample is to be carried out. 18 Carriage of oil tank of 20KL (01 Nos) capacity from 220 KV S/S Chinhat to 220 KV S/S Kursi Road distance upto 20 KM including loading and unloading at respective place and after work completion. Carriage of oil tanks of 20 KL (01 Nos.) from 220 K.V. Sub Station Kursi Road to 220 KV S/S Chinhat. 19 Delta earthing of 160 MVA Transformer consisting of fabrication of delta set with 03 Nos. 40 mm / 33 mm dia size 03 Mtr. ling electrode, its placing inside ground and connecting all the these electrode with 75x10mm M.S. Flat 700 mm deep and connecting the same with earthmat at two places. Also connecting delta to earth mat of substation at two places as per drawing provided by site engineer from UPPTCL. The work also to be done for painting the welding joint in black colour below earth level and green colour above ground level in two coats. (MS Rods & MS Flat will be provided by the department free of cost). 20 Erection of 132 KV LAs including erection of associated ALP structures, earthing of the LAs with existing M.S. Flat and jumpering with ACSR Zebra Conductors to connect with 132 KV Jack Bus with the help of ACSR Zebra Conductor, associated terminal connectors, P.G. Clamps etc. (01 Job per LA with associated structure). 21 Jumpering of HV side bushing of the 160 MVA transformer to connect with HV side CTs through 220 KV LAs with ACSR Zebra Conductor, associated terminal connectors etc. 22 Jumpering of LV side bushing of the 160 MVA transformer to connect with LV side CTs through 132 KV LAs with ACSR Zebra Conductor, associated terminal connectors, PG Clamps etc. 23 Laying of following size control cables from C&R panel to marshalling box/equipment/ junction box etc in switch yard for new 160 MVA T/F as per cable schedule along with saddling at every 750mm distance with MS saddles of size 25x3 sq mmincluding carriage of cable drums from store to laying site and shifting back remaoning drumsto store after work completion. The work shall also include interconnection of control cables with marshalling box , OLTC panel to RTCC panel, ferruling, dressing of cables and other associated works for satisfactory completion of job as per technical specificatons: 24 2C x 2.5 sq mm 25 4C x 2.5 sq mm 26 6C x 2.5 sq mm 27 10C x 2.5 sq mm 28 Erection of new 160 MVA TF RTCC panel including shifting from place of storage to ACDB room as per directions of site engineer (SDO/JE). 29 Earthing of main tank, marshalling box, drive mechanism, Transformer neutral, , RTCC panel etc of new 160 MVA Transformer with 50 x 6 mm and 75 x 10 mm size MS flats, its jointing with already existing earth mats/ deltas including necessary modification in existing support for earthing of neutral bushing for its earthing work and then painting of earthing strips as per technical specifications. 30 Making termination / connection of the control & power cables as per new cable schedule of 160 MVA Transformer, RTCC Panel, control & relay panel, cooling fans, pumps, marshalling box. OLTC, driving mechanism etc. dressing & binding of additional control cables, if required as per site requirement alongwith making necessary holes in the gland plate / box, wherever required including providing & fixing of cable glands of appropriate sizes providing of ferrules etc. 31 Testing of new 160 MVA Transformer 32 Conducting test of 160 MVA T/F (M/s TAL make) by arranging appropriate equipments for following items :-i. DGA test of Transformer oil & Water Content Test of Transformer oil 33 Conductioning test of 160 MVA T/F (M/s TAL make) by arranging appropriate equipments for following items :-1. WRM-01 No.2. Tan Delta-02 No. (Pre-erection and post-erection)3. Turret CT Ratio. Polarity, Knee Point continuity & I.R. Test 34 Work of re-erection, hydraulic testing, & commissioning of water spraying and fire detection mulsifyre system comprising of following detailed pipe lines with all cost of men, material, T&P etc required for the job as per details below: 35 Supply and installation of 80 mm dia B-class GI pipe for support with round clamp at top & flanges at bottom as per specifications including grouting and painting etc. 36 Providing, laying, installation , testing and commissioning of new 50 mm dia B class GI pipe with elbows, Tees, sockets, flanges, bends etc including its painting and connection to already dismantled existing pipe lines ( as may be required) 37 Providing, laying, installation , testing and commissioning of new 40 mm dia B class GI pipe with elbows, Tees, sockets, flanges, bends etc including its painting and connection to already dismantled existing pipe lines ( as may be required) 38 Providing, laying, installation , testing and commissioning of new 25 mm dia B class GI pipe with elbows, Tees, sockets, flanges, bends etc including its painting and connection to already dismantled existing pipe lines ( as may be required) 39 Supply, installation of HV nozzle projector HD make. 40 Supply, installation , testing of QB detector 41 Laying, installation, testing & commissioning of old G.I. Pipe B Class including cutting, welding etc. and providing suitable Flangs alongwith necessary fitting viz bends, elbow, tees, reducer, gasket etc.:- 42 25 mm dia. G.I. Pipe 43 50 mm dia. G.I. Pipe 44 65 mm dia. G.I. Pipe 45 80 mm dia. G.I. Pipe 46 100 mm dia. G.I. Pipe 47 150 mm dia. G.I. Pipe 48 Installation of HV nozzle projector 49 Installation of HV HD Fire detector 50 Erection, hydraulic testing & commissioning of complete mulsifyre system by installation of high velocity water spraying & fire detection system on 160 MVA 220/132KV TF by using old dismantled/newly laid additional pipe lines including providing of new gaskets/packings of required sizes along with necessary welding / jointing and earthing of pipe supports after re-construction of damaged RCC foundation for pipr supports. 51 Painting of above installed water spraying & fire detection system on 160 MVA 220/132KV TF in 02 coats of synthetic enamel paint after due application of 01 coat of red oxide primer after removal of old paint by rubbing with emery paper. The water pipe lines shall be painted in P.O. red color , Air pipe lines in sky blue color,Pipe supports in black color, earthing strips in Bus green color. 52 Electrical Safety processing fees needed for providing all relvant safety clearance documents from electrical safety department for energisation of the above commissioned 160 MVA Transformer and its accessories (Note: The amount payable is actual rate of challan or quoted rate, whichever is lower) 53 160 MVA Power Transformer 54 All LA (220/132 KV) associated with newly commissioned 160 MVA Transformer 55 HT inspection fees 56 Work of re-erection, hydraulic testing, & commissioning of water spraying and fire detection mulsifyre system on 132/33 KV 63 MVA M/s Atlanta make Transformer, comprising of following detailed pipe lines with all cost of men, material, T&P etc required for the job as per details below: 57 Providing, laying, installation , testing and commissioning of new 150 mm dia B class GI pipe with elbows, Tees, sockets, flanges, bends etc including its painting and connection to already dismantled existing pipe lines ( as may be required) 58 Supply and installation of 80 mm dia B-class GI pipe for support with round clamp at top & flanges at bottom as per specifications including grouting and painting etc. 59 Providing, laying, installation , testing and commissioning of new 40 mm dia B class GI pipe with elbows, Tees, sockets, flanges, bends etc including its painting and connection to already dismantled existing pipe lines ( as may be required) 60 Providing, laying, installation , testing and commissioning of new 25 mm dia B class GI pipe with elbows, Tees, sockets, flanges, bends etc including its painting and connection to already dismantled existing pipe lines ( as may be required) 61 Supply, installation of HV nozzle projector HD make. 62 Supply, installation , testing of QB fire detector 63 Replacement of diaphragm along with re-installation of quick opening flood, deluge valve HD make 150NB as per maximum working pressure 10kg/sq mtr of deluge valve system. 64 Erection, hydraulic testing & commissioning of complete mulsifyre system by installation of high velocity water spraying & fire detection system on 63 MVA 132/33 KV TF by using old dismantled/newly laid additional pipe lines including providing of new gaskets/packings of required sizes along with necessary welding / jointing and earthing of pipe supports after re-construction of damaged RCC foundation for pipe supports. 65 Painting of above installed water spraying & fire detection system on 63 MVA 132/33 KV TF in 02 coats of synthetic enamel paint after due application of 01 coat of red oxide primer after removal of old paint by rubbing with emery paper. The water pipe lines shall be painted in P.O. red color , Air pipe lines in sky blue color,Pipe supports in black color, earthing strips in Bus green color. 66 Following works including Providing of materials are to be carried out at 220 KV S/S Kursi Road Lucknow for Proper Lighting arrangement along the 160 MVA Transformer bay and other crucial places in switchyard with all cost of men, materials ,T&P etc . Except Cables Which shall be Provided by the Department as per direction of Supervising Engineer . 67 Providing of Lighting Junction Box of size of 280 mm x 150 mm made of 16 SWG M.S. B.P. Sheet & Painted with smoke Grey colour synthetic enamel Paint, duly fitted with 1 No 6 Amp. S.P. M.C.B. on Anodised M.S. Channel ,1 No Bakelite Fuse Fitting with 6 Amp. ,Capacity NS 6 type HRC Fuse,01 No . Copper Neutral Link ,Bakelite terminal strip of 4 Nos. terminals,Cable Glands suitable for 2C /4C x 2.5 Sq. mm size incoming /outgoingControl cable etc.& fixing on the GI Structure at designated height with the help of suitable duly fabricated M.S. Bracket Clamps and Due earthung of the Junction Box including Cable Terminations. 68 Providing & Fixing of G.I. S.L. Pole Bracket duly made of 40 mm dia B class 1.20 Meter long M.S. Pipe of (ID 35 mm& OD 40 mm) and bent at one end by quarter circle in 1.0 mtr. At an angle of 30 deg for fixing of 150 watt LED street Light Luminaries Fittings with the help of MS Bracket Clamps of suitable size for fixing on G.I. column structure at designated place. 69 Provinding & Fixing of 150 Watt LED Street Light Luminaries Fittings of PHILIPS/ CROMPTON / HAVELLS/ BAJAJ Make in Single Piece die cast aliminium Alloy Housing with Pot Optics Reflector & Toughed Clear Glass Cover with Frame for Lamp Compartment including Cable Termination . 70 Cable laying & Termination- 71 Laying of following size PVC insulated Copper Control cable from LT ACDB Cubical to Various Junction Boxes below ground level in PVC Conduit pipe (Provided by the contractor ) after due excavation ,back filling etc. including all labour ,PVC Pipe etc. required for proper completion of the work . 72 2 C x 2.5 Sq mm 73 Laying of Control cables between LT Lightinig Junction box & LED Street Light Fittings along GI Structure including necessary clamping with suitable M.S. street clamp with Proper Dressing . 74 Providing & fixing of Post Lamp Glow Light of latest design complete with white color defuser suitable for installation at main entrance/garden/lawn lighting. 75 Fabrication of protective net for radiators of 132/33 KV Transformers, control room glass window, JE room glass window and associated works: 76 Providing, fabrication and fixing of protection net in front of radiator of Trasformer, made of MS channel, angle, mesh and cross section type net. Size of protection net , including all cost of men and material- 77 132/33 KV 100 MVA Transformer M/s Atlanta make, size 2500x5000 sq mm for radiator and 6100x2500 sq mm for marshalling box (total area 27.75 sq mtr) 78 132/33 KV 63 MVA Transformer M/s Atlanta make, size 6000x2500 sq mtr for radiator 79 JE Room glass window 80 Control room glass window 81 Providing, fabrication and grouting of MS Channelin front of radiator by concreting for support of protection net by welding or nut & bolt as required , including all cost of men and material: 82 132/33 KV 100 MVA Transformer M/s Atlanta make, 4500 mm size at 4 places ( Total length 18 mtr ) 83 132/33 KV 63 MVA Transformer M/s Atlanta make, 4500 mm size at 2 places ( Total length 9 mtr) 84 JE Room glass window, 3000 mm size at 2 places ( total length 6 mtr) 85 Control room glass window , 3000 mm size at 4 places ( Total length 12 mtr) 86 Fabrication and fixing of 03 no. P.I. on the top of front protection for extra support of LV side conductor including all cost of men & material: 87 132/33 KV 100 MVA Transformer M/s Atlanta make 88 132/33 KV 63 MVA Transformer M/s Atlanta make 89 Spray/ brush Painting of following equipments/items painting includes one coat of red oxide and two coats of Green/Red colour good quality Asian/Burger/Nerolac make paint after through rubbing and cleaning of old scale of painted surface to remove rust,dust etc. 90 Earthing strip 75 x 10 mm in green Colour 91 Earthing strip 50 x 06 mm in green Colour 92 Switchyard lighting JB in smoke grey color 93 220KV CT/CVT in smoke grey color 94 220KV SF6 CB in smoke grey color 95 220KV & 132KV Isolator operating box in smoke grey color 96 132KV CT/CVT in smoke grey color 97 33 KV Isolator Operating Box in smoke grey colour. 98 33 KV CT & PT Junction Box in smoke grey colour. 99 Work and supply related to work of installation of CCTV camera at crucial places of substation for protection from theft and surveillance of store and switchyard equipment 100 Providing and fixing of outdoor Static (Bullet)IP 2MPCCTV Network camera having resolution 1920x1080,full HD 1080p video, 140 dB, WDR ,3d DNR smart heater ,Image sensor 1/2.8, progressive Scan CMOS,Shutter time 1/100000 Sec. Day and Night IR cut filter with auto Switch weather proof IP 67 protection,IR range 100-120 Meter Model No DS-2CD4A25FWDIZ(H)(S) of Hikvision make or equivalent model of BOSCH/CAME make. 101 Providing and fixing of Full HDoutdoor Dome IP 2MPCCTV camera having resolution 1920x1080,full HD 1080p video, digital WDR ,3d DNR smart heater ,Image sensor 1/2.8, progressive Scan CMOS,Day and Night IR cut filter with auto Switch weather proof IP 67 protection,IR range 50-70 Meter Model No DS-2CD432F-I(Z)(H)(S) of Hikvision make or equivalent model of BOSCH/CAME make. 102 Providing and fixing of 16 Channel Embedded plug and play NVR having 16 channel,2TB HD, SupportH.264+& h.264, 6 MP ,Integrated 16 Port PoE, HDMI, resolution 1920x1080p upto 2 SATA Interface, Model No7614NI-E2/16P of Hikvision make or equivalent model of BOSCH/CAME make. 103 Providing and Fixing of 32 Full HD LED TV (model No KDL-32W700B 80cm) of Sony make 104 Supply and fixxing of 3KVA on -Line UPS with isolation transformersuitable for single phaseAC power supply and single phase outputAC ,floor mounted type with 120 minut power backup APC make (modal No.SURTD3000XLI) or equivalent modelof standerd make. 105 Providing & fixing of 4TB Hard Disk of seagate make for storing the servilance data. 106 Providing & fixing of power supply board 24 Volt DC/24Amp AC of standard make. 107 Porviding & fixing of Power Over Eathernet (POE) Switch (08 Port), 10/1000 MBPS of D-Link make model No. DGS-1210-10P (08 Port) 10/100/1000 MBPS 108 Providing & laying 40 mm dia size HDPE pipe of standard make for laying of power supply cable/OFC/CAT-6 Data cable as per requirement. 109 Providing & laying of RG-60 3 GHZ Co-axial optical fiber cable of Fonolex/Standard make for CCTV wiring. 110 Providing & laying of Cat-6 Data Cable of D-link make for connecting PTZ Cameras to NVR. 111 Providing & laying of 3 Core 1.5 Sq. mm Multi Strnad Copper Wire Power Cable of Finolex/Standard make as per IS alongwith providing & fixing of Junction Boxes whereever required. 112 Providing of Computer Table of Godrej make as per sample. 113 Earthing of Cameras & NVR as per technical specification (01 Job each) 114 Work related to supply & installation of Fire Detection System operating on the basis of feedback by Smoke Detectors in BCUs, Store, ACDB room, Battery room, & office building at 220 KV substation Kursi Road Lucknow 115 Supply & installation of 08-12 Zone Conventional fire detection and fire alarm system with power supply arrangement. (Make compatible with IS: 2189:1999 tested by ERTL (N) and System Sensor (Agni suraksha/ Agni devices/ daksh OR equivalent). 116 Supply & installation of Manual Call Point A breakable glass cover fixed in such a way that the actuating push button is kept depressed as long as the glass is intact and released when the glass is broken. A small steel hammer shall be attached to the assembly with a steel chain to facilitate breaking of glass. The manual call points shall be suitable for surface or fully / partly recessed mounting. 5mm high red painting/printed word IN CASE OF FIRE BREAK GLASS shall be provided on the front face. The manual call point shall be compatible with all conventional control panels. (Make Agni Suraksha (ASES) / Safeway Equivalent Agni Devices). 117 Electronic hooter 11 dB/24V DC with strobe (ABS-V) The enclosure should be 1.5 mm thickness duly painted and marked FIRE ALARM. All hooters shall produce a similar sound and shall maintain the same during their operation. (Make Agni Suraksha (ASES) / Safeway Equivalent/ Agni Devices). 118 Providing & Fixing of lonisation type Smoke Detectors The detector while sensitive to all type of smokes will be insensitive to ambient lights, air drafts, and changes within the operating temperature and voltage ranges. The Detector shall meet the requirements of either EN 54/ FM/ UL or LPC and shall be specifically approved by FM/ UL/LPCB. Apollo / System Sensor /Edward/Bosch. 119 Providing & Fixing of Heat Detectors (for the area like Battery room, AC plant area, DG room, etc) It is a combination of rate of rise and fixed temperature principle using thermistor and with automatic compensation for changes of ambient conditions. The thermal detectors are tested and approved to EN54 part 5 (2000) Class A1R Apollo / System Sensor / Edward / Bosch/Agni suraksha. 120 Providing & Fixing of Response Indicator Lamp assembly consisting of lamp holder and lamp shall be suitable for mounting on walls, partition etc. The housing shall be suitable for surface/flush mounting of 1.5mm thick sheet steel and the facia 3mm acrylic mounted outside a cabin, and directly connected to the detector inside the cabin. In normal circumstances the lamp should flicker but in the event the detector inside the cabin senses a fire, the lamp should glow. 121 Supply and laying 2x1.5sqmm PVC insulated and sheathed stranded copper wire. Wiring for fire alarm system in general shall comply with IS: 2189 and IS: 732 amended up to date. The detectors shall be wired by ISI marked 1.5 sq mm PVC insulated stranded FRLS copper conductor wires of 1100 volts grade as required and desired on site. Crimping type of lugs are also included in the rates of laying wires and its connections.PVC insulated copper conductor wires shall confirm to IS: 694. And, PVC insulated copper conductor armoured cables should confirm to IS: 1554 (part-1). Make National/Plaza/Kalinga or any other standard make 122 Supply and laying 4x1.5sqmm PVC insulated and sheathed stranded copper wire. Wiring for fire alarm system in general shall comply with IS: 2189 and IS: 732 amended up to date. The detectors shall be wired by ISI marked 1.5 sq mm PVC insulated stranded FRLS copper conductor wires of 1100 volts grade as required and desired on site. Crimping type of lugs are also included in the rates of laying wires and its connections. Make National/Plaza/Kalinga or any other standard make 123 Supply and installation of SMF Batteries with suitable rating as required for 24 Hours backup from Exide / Standard / Amco Prestolite/any other standard make. 124 Signage with backlit facility for Control building marking for various Fire / emergency exit points. 125 Supply and laying of Ms/PVC conduit pipe 25mm as per Requirement of site. 126 Provising, fixing & installation of different types of boards i.e. Glow Sign Board, Shutdown Notice Board, Instruction Board etc as detailed bwlow, to be carried out at 220KV substation Kursi Road Lucknow as per specifications and directions of supervising engineer: 127 Providing, fixing and installation of Glow Sign Board of size 10 ft x 6 ft for substation single line diagram to be fixed in control room building of the substtaion. The Glow Sign Board should be illuminated using sufficient number of LED tube lights. The board shall be made of ACrilic sheet and shall be provided with back support frame & fixing arrangement. 128 Name plates made of 2mm thick Aluminium Sheet coveredwith 3 M HIP retro reflective sheet of following size with details / name written by 3M HIP Retro reflective sheet as per prescribed color scheme to be fixed with the help of nuts & bolts at already installed equipment structure in switchyardwith all cost of plates, nut-bolts, misc materials, T&Pand labour as per specificatins & directions of supervising engineer: 129 300mm x200mm 130 450mm x 250mm 131 500mm x 250mm 132 R,Y,B phase plate sets consisting of one plate of red,, yellow, blue colors in each set & plates of dia 250mm duly made of 2mm thick aluminium sheet with face to be fully covered in red , yellow, blue phase colors in 3 M HIP retro reflective sheetand the phase plate set to be fixed with the help of suitable size G.I. bolts, nuts on already installed equipment structure etc at the substation.
Contract Date : Ref. Documents   |   Contract Value : Ref. Documents
Disclaimer

We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.

Tender Detail
Website sandesh_rajkot