Tender Summary / Eligibility Criteria
Tender for Work of 220 KV Bus, Fly over Bus, feeder bay Jumper Replacement work Approved R M Plan 2020-21 at 220 KV Halvad SS under AM Div. Dhrangadhra
Documents
Download All
No Boq
No Corrigendum
Probable Bidders
AI engine predicts probable bidders to help you bid strategically.
MSME Exception
Technical
Tender involves procurement of high capacity electrical equipment including diaphragm coupling of pump &
motor with 90kW capacity at 2900 RPM. The project scope includes installation, testing, commissioning and
operational handover.
Previous / Similar Result
BRR : 1522450
Tender For Repair / Maintenance To Ht Oh Lines, Ug Cables, Transformers And Other Connected Items At Domestic And Technical Area At Afs Sarsawa Under Ge ( Af ) Sarsawa ; 1 Disconnecting Ht / Lt Cables & Earthing Connectionsof Burnt / Defective Transformer Of Capacity 50Kva To 630Kva, 11Kv / 433 Volts, 3 Phase, From Pole / Floor Mounted, Taking Down From Site Of Installation Carefuly With The Help Of Cranes And Transporting The Same To Workshop For Repair, Opening, Draining Out Transformer Oil, Dismantling Complete & Taking Out Core Assembly & Removing Burntout Windings, Cleaning / Washing Of Tank Removing The Dirt Sludge And Sticky Materials From All Parts Of The Transformerincluding Core Tank And Cooling Tubes, Removal Of Damaged Parts, Dehydrating The Core Assembly, Re-Assembling After Replacement Of Damaged Parts Of The Transformer After Repairs, Making Connections And Filling Dehydradated / Fresh Transformer Oil And Testing For All Type Of Tests ( Routine Test & Full Load Test ) Including Transportation Back & Reinstallation / Connection Of Transformer At Site Complete All As Specified & Directed..Notes:- ( I ) Spare Parts Shall Be Measured And Paid Seperately. Taking Down / Out Of Old Spare Parts Are Included In Quoted Rates If Specifically Not Otherwise Specified Here-In-After. ( Ii ) All Parts / Components Replaced Shall Be Identical To Those Specified By Original Manufacturer. ( Iii ) Winding, New Transformer Oil & Dehydration Of Old Transformer Oil Shall Be Measured & Paid Separately. ( Iv ) The Repair / Maintenance Shall Be Carried From Oem Or Authorized Agency Of Oem As Approved By The Ge. 2 M&L Winding Of Transformer Any Capcity At Lt Side With Copper Strip Of Suitable Size / Gauge, Fixing The Coil In The Position In Core Assembly And Making Connection As Per Original Pattern Including Providing Insulation, Complete All As Specified & Directed. 3 M&L Winding Of Transformer Any Capcity At Ht Side With Super Enamelled Copper Wire Of Suitable Size / Gauge, Fixing The Coil In The Position In Core Assembly And Making Connection As Per Original Pattern Including Providing Insulation, Complete All As Specified & Directed. 4 S&F Tap Changer Switch Suitable For Transformer 50Kva To 200Kva Complete All As Specified & Directed. 5 S&F Tap Changer Switch Suitable For Transformer 250Kva To 630Kva Complete All As Specified & Directed. 6 M&L Oil Temperature Gauge / Thermometer Suitable For Transformers Of Any Make, Model , Location Etc With Shape And Size As Existing At Site Complete All As Specified & Directed. 7 S&F Ht Bush Assembly Made Out Of Brass With Heavy Duty Brass Complete With Brass Spindle, Nuts, Bolts, Washers Etc Without Bushing Insulators All As Per Existing Size, Shape And Length Suitable For 50Kva To 63 Kvacapacity Transformerscomplete All As Specified & Directed.. 8 Description All As Per Boq Item No. 7.00 Here-In-Above But For 100 Kva To 200 Kvacapacity Transformers. 9 Description All As Per Boq Item No. 7.00 Here-In-Above But For 250 Kva To 630 Kvacapacity Transformers. 10 S&F Lt Bush Assembly Made Out Of Brass With Heavy Duty Brass Complete With Brass Spindle, Nuts, Bolts, Washers Etc Without Bushing Insulators All As Per Existing Size, Shape And Length Suitable For 50Kva To 63 Kvacapacity Transformerscomplete All As Specified & Directed. 11 Description All As Per Boq Item No. 10.00 Here-In-Above But For 100 Kva To 200 Kvacapacity Transformers. 12 Description All As Per Boq Item No. 10.00 Here-In-Above But For 250 Kva To 630 Kvacapacity Transformers. 13 S&F 11 Kv Porcelain Bushing Insulators For Ht Side, Outdoor / Indoor Type Transformer Of Capacity 50Kva To 63Kva As Per Is-2099 Of 1973 Complete All As Specified & Directed.. 14 Description All As Per Boq Item No. 13.00 Here-In-Above Buttransformer Of Capacity 100Kva To 200Kva 15 Description All As Per Boq Item No. 13.00 Here-In-Above Buttransformer Of Capacity 250Kva To 630Kva 16 S&F 433 Volt Porcelain Bushing Insulators For Lt Side, Outdoor / Indoor Type Transformer Of Capacity 50Kva To 63Kva Complete All As Specified & Directed.. 17 Description All As Per Boq Item No. 16.00 Here-In-Above Buttransformer Of Capacity 100Kva To 200Kva 18 Description All As Per Boq Item No. 16.00 Here-In-Above Buttransformer Of Capacity 250Kva To 630Kva 19 S&F Cork Sheet Gasket, 6 Mm Thick, Superior Quality, On Top Cover Plate Of The Transformer 50Kva To 630 Kva Complete All As Specified & Directed. 20 S&F In Replacement Gun Metal Globe Or Gate Valve 20 / 25 Mm Bore, Isi Marked, Class-2With Spindle And Iron Wheel Head, Screwed Both Ends For Iron Pipe With & Including Fittings And Fixturescomplete All As Specified & Directed. 21 Taking Down / Out Old Unservieableair Break Gang Operated Switch, Removing God Including Supply And Installing Switch Air Break Gang Operated, Triple Pole, For Horizontal Or Vertical Operation, Mechanically Operated, Mounted On 12 Insulators And Steel Frame With Operating Mechanism & Operating Rod Of 25Mm Bore, Medium Grade Gi Pipe From Ground Level With Locking Arrangements, 200 Amps Rating 11000 Volts Working Pressure Including Making Electrical Connectionsto Make It Functional After Testing Complete All As Specified & Directed. 22 S&F In Replacement Ht / Lt Side Cable Box Cover Plate Made Out Of Ms Sheet Of 16 Swg Complete With Nuts, Bolts, Washers, Gasket & Painting Suitable For Indoor / Outdoor Type Transformer Of Capacity 50Kva To 630Kva Complete All As Specified & Directed.. 23 Taking Out Breather Assembly From The Transformer Of Any Make, Capacity 50Kva To 63 Kva, Removing Of Moisturized / Unserviceablesilica Gel With And Including Supply Of New Breather Assembly And Pouring Of Silica Gel With Fresh Deep Blue Coloured Silica Gel All As Per Existing At Site Complete All As Specified & Directed.. 24 Description All As Per Boq Item No. 23.00 Here-In-Above But Capacity 100Kva To 200Kva 25 Description All As Per Boq Item No. 23.00 Here-In-Above But Capacity 250Kva To 630Kva 26 Disconnecting Of All Ht / Lt Cable & Earthing Connections Of Transformer Of Capacity 50Kva To 63Kva , 11Kv / 433Volt, 3 Phase, Any Make, From Pole / Floor With The Help Of Crane To Carryout Overhauling Of Transformer Comprising Of Following Services Complete All As Specified & Directed:- ( I ) Opening Of Top Cover, Disconnecting Winding Connection From Bushing And Taking Out Carefully Core Assembly Complete With Winding ( Ii ) Draining Out Of Transformer Oil From Chamber ( Iii ) Checking Compactness Of Core & Tightening The Same Wherever Required ( Iv ) Chemical Washing Of Winding To Remove Dirt, Dust & Carbon Particles. ( V ) Cleaning Of Oil Tank To Revmove Oil Sludge Followed By Painting Inner Surface Of Tank With Zinc Chromate Base Paint ( Vi ) Refixing Of Core & Winding Assembley And Making Connection With Ht / Lt Bushing ( Vii ) Replacement Of Worn Out Gaskets Nut / Bolts With New One. ( Viii ) Refilling The Transformer Oil After Filtering / Dehyderation Or Filling New Transformer Oil. ( Ix ) Satisfactory Testing Of Transformer On Full Load.Note: ( I ) The New Transformer Oil & Dehydration Of Transformer Oil Shall Be Measured & Paid Sepratrly. ( Ii ) The Repair / Maintenance Shall Be Carried From Oem Or Authorized Agency Of Oem As Approved By The Ge. 27 Description All As Per Boq Item No. 26.00 Here-In-Above But Transformer Of Capacity 100Kva To 200Kva 28 Description All As Per Boq Item No. 26.00 Here-In-Above But Transformer Of Capacity 250Kva To 630Kva 29 Dehydration / Centrifuging Transformer Oil By Means Ultra High Vaccum Double Stage Machine To Remove Impurities From Oil Such As Moisture, Dirt, Air And Other Gases At Site Of Installation In Running Condition Of Transformer Including Testing The Oil Before And After Centrifuging From Top And Bottom Of Transformer To Achieve The Bdv Value More Than 45Kv ( Rms ) At 2.5Mm Air Gap Complete All As Specified & Directed..Note:- ( I ) Oil Test Value Record Register Shall Be Prepared In Presence Of Engineer-In-Charge / Jeand Handed Over The Register To Sub Division On Completion Of Work. ( Ii ) The Contractor Is Required To Submit The Di-Electric Repot After Dehydration And Filtration Of Each Transformer Before Claiming Payment. 30 Supply Only Transformer Oil Of Dielectric Strength Not Less Than 45 Bdv To Comply Is-335 Of 1993 In Company Sealed Barrels Complete All As Specified & Directed.Note:- Empty Container Shall Be Returned To Contractor After Use Of Oil. 31 Preparation Of External Surfaces Of Transformer Of Capacity 50Kva To 200 Kva For Paintingincluding Fins / Radiators, Removal Of All Rust / Oil / Grease And Unwanted Material And Applying Two Coats Of Synthetic Enamel Metallic Paint, Smoke Grey, By Means Of Spray Gun At Site Of Installation Of Transformer Including Writing Sm / Mes Number, Capacity Of Transformer Etc With Black Synthetic Enamel Paint Complete All As Specified & Directed. 32 Description All As Per Boq Item No. 31.00 Here-In-Above But Transformer Of Capacity 250Kva To 315Kva. 33 Description All As Per Boq Item No. 31.00 Here-In-Above But Transformer Of Capacity 400Kva To 630Kva. 34 M&L Cleaning And Preparation Of Surfaces Of Ht Steel Tubular Poles ( Six Pole Structure Having Channels Upto 54 Nos. Of Length Upto 2.5Mtr, Various Angle, Clamps, Anticlimb Device ) With Emery Paper, Filling The Voids With Suitable Filler Materials And Applying Two Coats Of Aluminium Paint Over & Including One Coat Of Zinc Oxide Primer To Poles, Cross Arms, Brackets, Hooks, Junction Box, Stay Clamps With And Including Making Blue & White Strip 30Cm Wide ( 5 Nos ) Upto 1.5 Mtr From Pcc Coping And Marking The Numbering On Poles With Synthetic Enamel Paint Complete All As Specified & Directed. 35 M&L Cleaning And Preparation Of Surfaces Of Ht Steel Tubular Poles ( Four Pole Structure Having Channels Upto 28 Nos. Of Length Upto 2.5Mtr, Various Angle, Clamps, Anticlimb Device ) With Emery Paper, Filling The Voids With Suitable Filler Materials And Applying Two Coats Of Aluminium Paint Over & Including One Coat Of Zinc Oxide Primer To Poles, Cross Arms, Brackets, Hooks, Junction Box, Stay Clamps With And Including Making Blue & White Strip 30Cm Wide ( 5 Nos ) Upto 1.5 Mtr From Pcc Coping And Marking The Numbering On Poles With Synthetic Enamel Paint Complete All As Specified & Directed. 36 M&L Cleaning And Preparation Of Surfaces Of Ht Steel Tubular Poles ( Two Pole Structure Having Channels Upto 07 Nos. Of Length Upto 2.5Mtr, Various Angle, Clamps, Anticlimb Device ) With Emery Paper, Filling The Voids With Suitable Filler Materials And Applying Two Coats Of Aluminium Paint Over & Including One Coat Of Zinc Oxide Primer To Poles, Cross Arms, Brackets, Hooks, Junction Box, Stay Clamps With And Including Making Blue & White Strip 30Cm Wide ( 5 Nos ) Upto 1.5 Mtr From Pcc Coping And Marking The Numbering On Poles With Synthetic Enamel Paint Complete All As Specified & Directed. 37 M&L Cleaning And Preparation Of Surfaces Of Ht Pcc Poles ( Four Pole Structure Having Channels Upto 28 Nos. Of Length Upto 2.5 Mtr ) And Applying Two Coats Of Exterior Cement Base Paint Over & Including One Coat Of Primer To Poles And Applying Two Coats Of Aluminium Paint Over & Including One Coat Of Red Oxide Primer To Cross Arms, Brackets, Hooks, Junction Box, Stay Clamps, And Making Blue & White Strip 30Cm Wide ( 5 Nos ) Upto 1.5 Mtr From Pcc Coping And Marking The Numbering On Poles With Synthetic Enamel Paint Complete All As Specified & Directed. 38 M&L Cleaning And Preparation Of Surfaces Of Ht Pcc Poles ( Two Pole Structure Having Channels Upto 07 Nos. Of Length Upto 2.5 Mtr ) And Applying Two Coats Of Exterior Cement Base Paint Over & Including One Coat Of Primer To Poles And Applying Two Coats Of Aluminium Paint Over & Including One Coat Of Red Oxide Primer To Cross Arms, Brackets, Hooks, Junction Box, Stay Clamps, And Making Blue & White Strip 30Cm Wide ( 5 Nos ) Upto 1.5 Mtr From Pcc Coping And Marking The Numbering On Poles With Synthetic Enamel Paint Complete All As Specified & Directed. 39 M&L Cleaning And Preparation Of Surfaces Of Angle Iron By Emmery Paper And Applying Two Coats Of Synthetic Enamel Paint Over & Including One Coat Of Zinc Oxide Primer To Angle Iron And Two Coats Ofaluminium Paint To Chain Link Fencing Around The Transformer Yards With And Including Applying Two Coats Of Exterior Cement Base Paint To External Surfaces Of TransformerS Platform Including Stairs Etccomplete All As Specified & Directed.. 40 M&L Cleaning And Prepartion All Metal Parts Of 33 / 11 Kv Main Receiving Station And Applying Two Coats Of Aluminium Paint Over & Including One Coat Of Zinc Oxide Primer Including Painting To CtS / Gods, Chain Link Fencing, Angle Iron Posts Around The Transformer Yards With And Including Two Coats Of Exterior Cement Base Paint To External Surfaces Of TransformerS Platform Including Fire Walls Etccomplete All As Specified & Directed. 41 Supply, Laying, Jointing, Testing & Commissioning In Replacement Ht Xlpe Cable ( Heavy Duty ) , 11000 Volts ( Earthed ) , Cross Sectional Area 95 Sqmm, 3 Core, Insulated, Screened, Sound Compacted Aluminium Conductor, Screening With Extruded Semi Conducting Layers, Insulation Screening With Copper Tape Covers Laid Up With Pvc ( St-2 ) , Extruded Inner Sheathed Gi Strip Armoured Pvc ( St-2 ) Out Sheathed, Isi Marked With Is-7098 Part Ii With Amendment Upto Date, Laid In Trenches / Pipes / Ducts Or Fixed Along Poles / Walls Etc Complete All As Specified & Directed.. Notes:- ( I ) Cable Shall Be Of Manufacturing Date Not Earlier Than Jul 2023. All The Cable Shall Be Embossed With Year Of Manufacturing, Meterage At Every Metre, In Addition To Its Own Standard Markings As Per Is I.E. Size, Voltage Etc. ( Ii ) Excavation & Earth Work, Sand Cushioning, Protection Pipes, End Termination Joints & Protection Covers Shall Be Measuredand Paid Separately. 42 Excavation In Trenches, Not Exceeding 1.5Mtr Wide & Not Exceeding 1.5Mtr In Depth; For Foundation, Laying / Taking Out Pipes / Cables Etc. Or For Shafts, Wells, Cesspits, Manholes, Pier Holes, Etc. Not Exceeding 10Sqm On Plan & Not Exceeding 1.5Mtr In Depth And Getting Out, In Any Type Of Soil Complete All As Specified & Directed. 43 Excavation In Trenches, Not Exceeding 1.5Mtr Wide And Exceeding 1.5 Mtr But Not Exceeding 3.0 Mtr In Depth; For Foundation, Laying / Taking Out Pipes / Cables Etc. Or For Shafts, Wells, Cesspits, Manholes, Pier Holes, Etc. Not Exceeding 10Sqm On Plan And Exceeding 1.5 Mtr But Not Exceeding 3.0 Mtr In Depth And Getting Out, In Any Type Of Soil Complete All As Specified & Directed. 44 Returning Filling In Including Spreading Leveling Watering And Well Ramming In Layers Not Exceeding 25Cm Thick Each In Any Type Of Soil Complete All As Specified & Directed. 45 Removal Of Excavatedsurplus Soil To A Distance Not Exceeding 50 Mtr & Depositing Where Directed At A Level Not Exceeding 1.5 Mtr Above The Starting Point Complete All As Specified & Directed. 46 M&Lun-Reinforced Precast Concrete Cable Cover, Class Hv Type-1, Flat, Size 300Mm X 180Mm X 40Mm, Laid Flatfor Protection Of Cable, Adjacent To Each Other, Perpendicular To Central Axis Of Cable Complete All As Specified & Directed. 47 M&Lsand Cushioning With Fine Dry Sand To Cable With A Layer Of Sand 8 Cm Thick Before Laying The Cable And 15 Cmthick After Laying The Cable ( Punned Down To 18 Cm Thick After Laying And Stretching Of Cable ) Complete All As Specified & Directed. 48 S&F In Replacement Cable Route Indicator, Showing Mes Ht Under Ground Cable And Arrow Mark Painted With Two Coat Synthetic Enamel Paint Over & Including One Coat Of Zinc Oxide Primer, Made Out Of Ms Plate Of Size 200Mm X 200Mm, 6Mm Thick Fixed On Ms Flat Of Size 25Mm X 4Mm, 600Mm Long, Including Cutting, Chasing, Drilling, Welding Etc. ( Whichever Required ) And Embedded In Pcc Block 1:3:6, Type C-2 Of Size 30Cm X 30Cm X 30Cm In The Ground Including Excavation And Earth Work Complete All As Specified & Directed.Note: Excavation & Earthwork And Pcc Work Included In Quoted Rates. 49 M&Lin Replacement Double Wall Corrugated ( Dwc ) Hdpe Pipe Outer Dia 90Mm & Inner Dia 75Mm As Per Is 14930 ( Part-2 ) :2001 With End Cap Laid As In Trenches / Under Road / Under Floor Or Fixed To Wall / Pole With Fixing Arrangement With Suitable Size Of Ms Clamps For Cable Protectioncomplete All As Specified & Directed. . 50 S&F In Replacement Cable Jointing Kitfor 11000 Voltearthed Grade, Straight Through, Heat Shrinkable Type Joints With Jointing Material And Accessories Suitable For 3 Core Xlpe Armoured Aluminium Conductor Cable Of Size95sqmm Complete All As Specified & Directed. 51 S&F In Replacement Cable Jointing Kitfor 11000 Voltearthed Grade, Outdoor Type, End Termination Heat Shrinkable Type Joints With Jointing Material And Accessories Suitable For 3 Core Xlpe Armoured Aluminium Conductor Cable Of Size 50Sqmm To 95Sqmm Complete All As Specified & Directed.. 52 S&F In Replacement Cable Jointing Kitfor 11000 Voltearthed Grade, Indoor Type, End Termination Heat Shrinkable Type Joints With Jointing Material And Accessories Suitable For 3 Core Xlpe Armoured Aluminium Conductor Cable Of Size 50Sqmm To 95Sqmm Complete All As Specified & Directed. 53 Cutting The Worn Out / Unserviceable Lugs From The Cables Of Size Upto 50 Sqmm Size With And Including Supply & Fixing Lugs After Cutting The Worn Out / Faulty Cable End Fromht / Lt Side Of Transformer / Lt Pillar / Panel Box Including Necessary Earth Work For Taking Out The Cable From Loop, Returning Fillingetc And Providing Aluminium Lugs Lead Including Crimping With Crimping Tools In The Existing Lt Cable And Making Necessary Connections To Make It Functional Complete All Asspecified & Directed. 54 Description All As Per Boq Item No. 53.00 Here-In-Above Butcables Of Size 70 Sqmm To 120 Sqmm. 55 Description All As Per Boq Item No. 53.00 Here-In-Above Butcables Of Size 150 Sqmm To 185 Sqmm 56 Description All As Per Boq Item No. 53.00 Here-In-Above Butcables Of Size 240 Sqmm To 300 Sqmm 57 S&F Composite Polymer 11 Kv, Pin Insulator Alongwith Pin 260 Mm Long Creepage Distance 320 Mm Pf Dry / Wet Withstand Voltage Kv / Mint 65 / 40 After Taking Down / Out Insulator As Existing At Site Complete All As Specified & Directed.. 58 S&F Pin Type Insulator Capacity 33000Volt After Taking Down / Out Insulatoras Existing At Site Complete All As Specified & Directed.. 59 S&F In Replacement Ht Lightning Arresters For Outdoor Use, Non-Liner Resistor Type, Horn Gap And Choking Coil, Maximum Working Pressure 11000 Volts, Transmission Class, Discharge Capacity 65 Kiloampere Complete All As Specified & Directed.. 60 M&L Defect Rectificatoin Of Ht 11 Kv Cable Laidin Trenches By Locating Fault With The Help Of Electronic Fault Locating Machine Comprising Of Surge Generator Pulse, Cable Route Tracer, Echo Fault Locator With Hight Frequency Distance Calculator Etc Including And Additional Excavation In Normal Alluvial Strata Required For Exposing The Cable Fault, Removal Of Deteriorated Potion Of Cable, Treating Of Cable And Keeping The Same Ready For Jointing Work For Cable Of Size Up To 185 Sqmm 3 Core Complete All As Specified & Directed.Note: The Fault Locating Equipments Will Be Brought To Site Within 24 Hours Of Instruction From Engineer-In-Charge. S&F Of Cable Joints Shall Be Measured & Paid Seperately. 61 S&F In Replacement 33Kv, 10 To 25 Amp, Do Fuse Complete All As Specified & Directed. 62 S&F In Replacement 33 Kv, 30 Amp, Do Fuse Complete All As Specified & Directed.. 63 S&F In Replacement 33 Kv, 40 Amp, Do Fuse Complete All As Specified & Directed.. 64 S&F In Replacement 11Kv, 10 To 25 Amp, Do Fuse Complete All As Specified & Directed. 65 S&F In Replacement 11Kv, 30 Amp, Do Fuse Complete All As Specified & Directed.. 66 S&F In Replacement 11Kv, 40 Amp, Do Fuse Complete All As Specified & Directed.. 67 M&L In Replacement True Vertical Steel Tubular, Swaged Welded Pole Conforming To Is-2713 Part Ii , Type 410 Sp 55, 11 Metre Long Complete With Mild Steel Base Plate Of 6 Mm Thick Of Size 300Mm X 300Mm, Finial Taper Plug, Cap, Bolts, Nuts, Washer And Screws Hole Of Required Size And Nos. For Fixing Cross Arms Including Painting Externally With Two Coats Of Aluminium Paint Over & Including One Coat Of Zinc Oxide Primer For Exposed Surface And Two Coats Of Black Bituminious Paint For Embeded Portionin Concrete As Well As Throughout Internally Including Provision Of White & Blue Colour Strips With Fluorescent Paint Upto 1.5 Mtr Height & Nubmering Of Pole Complete All As Specified & Directed..Note:-Excavation, Earth Workandpccshall Be Measured And Paid Separately. 68 M&L Plain Cement Concrete ( Pcc ) 1:4:8, Type D-2 Using 40 Mm Graded Mechanically Crushed Stone Aggregates As In Foundations, Filling And Mass Concrete Etc Complete All As Specified & Directed. 69 M&L Plain Cement Concrete ( Pcc ) 1:3:6, Type C-2, Using40 Mm Graded Mechanically Crushed Stone Aggregates As In Foundations, Filling And Mass Concrete Etc Complete All As Specified & Directed. 70 M&L Plain Cement Concrete ( Pcc ) 1:2:4, Type B-1, Using20 Mm Graded Mechanically Crushed Stone Aggregates As In Coping To Pole / Stay / Panel Etcincluding Necessary Formwork To Exposed Surface Finished Even & Smooth Complete All As Specified &Directed. 71 S&F Aluminum Conductor Steel Reinforced ( Acsr ) Any Typeweasel, Beaver, Ferret, Mink Including Stretching On Insulators With Aluminium Taps, Jumping, Binding On Poles With Minimum Sag Including Binding Wire, Jointing Sleeves, And Pg Clamps Ofsuitable Size Including Dismantling Of Old Acsr As Existing At Site Complete All As Specified & Directed.Notes :-The Rates Quoted Includes ( I ) Jumper Oncutout Point, 2 Pole / 4 Pole Structureshall Be Provided With Pvc Sleeves . ( Ii ) Cutting Of Branches Of Trees Coming Across The Oh Line. 72 S&F Cross Arms, Bracings, Supports, Clamps And Back Plates Fabricated From Structural Steel Sections Including Nuts, Bolts, Washers, Welding, Bending Cold Or Hot, Drilling Holes For Bolts, In Any Shape Or Size As Indicated Or Directed And Applying Two Coats Of Aluminium Paintover & Including One Coat Of Zinc Oxide Primerincluding Dismantling Of Old Unserviceable Cross Arm As Existing Complete All As Specified & Directed.. 73 S&F Anti Climbing Device , Spikes Type Fabricated Out Of Ms Bars , Round Square And Flat With And Including Providing Required Nuts , Bolts, Washers Etc., Welding In Two Halves, Made To Shape, To Suit The Cross Section Of The Pole And Applying Two Coats Of Aluminium Paint Over & Including One Coat Of Zinc Oxide Including Dismantling Of Old Unserviceable Climbing Device As Existing Complete All As Specified & Directed. 74 M&L In Replacement Danger Notice Plate Of 1.6 Mm Thick Mild Steel Sheet, Vitreous Enamelled White, With Letters , Figures And Conventional Skull And Bones In Signal Red Colour, Fixed With Ms Clamps , Bolts And Nuts, For Ht Of 25 Cm X 20 Cm Size As Per Ssr Part-I 2009 Complete All As Specified & Directed.. 75 S&Fin Replacement Cast Resin Cts Ratio 60-30 / 5 A +5, Class I, 26.3 Ka, Type Ectt 3, ( Set Of Three ) For Out Going Feeders Complete All As Specified Directed. 76 S&Fin Replacement Cast Resin Ctsratio 100-50 / 5 A +5 Class I, 26.3 Ka, Type Ectt 3 ( Set Of Three ) For Out Going Feeders Complete All As Specified & Directed.. 77 S&F In Replacement 11 Kv, Single Phase, Indoor Resin Cast, Pt Of Ratio 11 Kv / Rt 3 / 110V / Rt 3 / 110V / Rt 3, Class 0.5-3, Burden 50 Va - 50 Va, Insulation Level 28 / 75 Kv, Voltage Factor 1.2 Cont And 1.9 For 30 Sec, ( Set Of Three ) Conforming To Is-3156 Complete All As Specified & Directed. 78 S&F 3 Phase Over Current And Earth Fault Relay With Instantanteous High Set Functions After Taking Down / Out Relayas Existing At Site Complete All As Specified & Directed.. Make: L&T Model No Mc61a-Nxor Equivalent In Legrand And Crompton Greaves. 79 Labour For Augering Upto 100Mm Bore For Road Crossing 3 Mtr To 10 Mtr ( In Length ) Not Exceeding 1.5 Mtr In Depth For Laying Of Electric Cable And Gi Tubing In Soft / Loose Soil Complete All As Specified. 80 Supply, Installation, Testing & Commisioning Outdoor Type Feeder Pillar Box Suitable For 11 Kv, Made Out Of 3.15Mm Thick Ms Sheet, Powder Coated, Dust And Vermin Proof With Rain Water Protection, Double Door Type With Locking Arrangements Of Size 1.2Mtr X 1.2Mtr X 0.6Mtr ( Minimum ) With Provision Of Ht 11 Kv Post Insulators. 3 Nos Fixed Inside With Suitable Size Of Copper Busbars For Cable Connections And Danger Notice Plate, Panel To Be Fixed At 45Cm Above Ground Level On Brick Masonry Plateform Including 75Mm Thick Pcc ( 1.3.6 ) , Type C1 ( Using 20 Mm Graded Stone Aggregates ) Around The Area Upto 1.5Mtr In All Directions From The Panel, Cable Joints Inside The Panel Provided With Suitable Insulators And Copper Bus Bars Inlcuding Dismantling Of Old Feeder Pillar Box As Existing At Site Complete All As Specified & Directed. 81 S&F In Replacement Post Insulator 11 Kv Porcelain Typesuitable For 11Kv Gooat 2 Pole / 4 Pole Structure Complete All As Specified & Directed. 82 S&F In Replacement Male Contact Blade Suitable For 11Kv Gooat 2 Pole / 4 Pole Structure Complete All As Specified & Directed. 83 S&F In Replacement Moving Contact Blade Suitable For 11Kv Gooat 2 Pole / 4 Pole Structure Complete All As Specified & Directed. 84 S&F In Replacement Female Contact Jaw Suitable For 11Kv Gooat 2 Pole / 4 Pole Structure Complete All As Specified & Directed. 85 S&F In Replacement Fix Contact Jaw Suitable For 11Kv Gooat 2 Pole / 4 Pole Structure Complete All As Specified & Directed. 86 S&F In Replacement Tinned Copper Flexible Jumper 200 Ampsuitable For 11Kv Gooat 2 Pole / 4 Pole Structure Complete All As Specified & Directed. 87 S&F In Replacement Ms Jumper Carriersuitable For 11Kv Gooat 2 Pole / 4 Pole Structure Complete All As Specified & Directed. 88 S&F In Replacement Back Connector Plate Suitable For 11Kv Godat 2 Pole / 4 Pole Structure Complete All As Specified & Directed. 89 S&F In Replacement Operating Lever Made Of Msfor Verticle Mounting Suitable For 11Kv Gooat 2 Pole / 4 Pole Structure Complete All As Specified & Directed. 90 S&F In Replacement Operating Gi Pipe Medium Grade 25 Mm Bore Length 5 Mtrsuitable For 11Kv Gooat 2 Pole / 4 Pole Structure Complete All As Specified & Directed. 91 S&F In Replacement Arcing Horn Made Of Mild Steel Suitable For 11Kv Gooat 2 Pole / 4 Pole Structure Complete All As Specified & Directed. 92 S&F In Replacement Terminal Pad Made Of Copper Suitable For 11Kv Gooat 2 Pole / 4 Pole Structure Complete All As Specified & Directed. 93 S&F In Replacement Contact Pressure Leaf Strips Suitable For 11Kv Gooat 2 Pole / 4 Pole Structure Complete All As Specified & Directed. 94 S&F In Replacement Phase Coupler Rodsuitable For 11Kv Gooat 2 Pole / 4 Pole Structure Complete All As Specified & Directed. 95 S&F In Replacement Spring With Teflon Insert Suitable For 11Kv Gooat 2 Pole / 4 Pole Structure Complete All As Specified & Directed. 96 S&F In Replacement Terminal Connector With Bimetallic Strip Suitable For 11Kv Gooat 2 Pole / 4 Pole Structure Complete All As Specified & Directed. 97 S&F In Replacement Fuse Elements Suitable For 11Kv Gooat 2 Pole / 4 Pole Structure Complete All As Specified & Directed. 98 M&L In Replacement Earthing Complete With Galvanized Steel Earth Plate Electrode 60 Cm X 60 Cm, 6Mm Thick Thick Buried Vertically In Ground To Depth Not Less Than 2.25 Mtr Below Ground Level, With Top Edge Of Earth Plate Not Less Than 1.5 Mtr Below Ground Level, Connected To Gi Earth Lead Strip 32Mm X6mm Upto 7.5 Mtr Long By Means Of Bolts, Nuts, Check Nuts And Washers Of Galvanized Iron And Connection To Earthing Test Point& Earth Dolly & Gi Pipe Medium Grade 20 Mm Bore 1.5 Mtr Long For Watering Including Gi Pipe Medium Grade 40Mm Bore Upto 7.5 Mtr Long For Protection Of Earth Lead, Wire Mesh, Funnel, Lugs, Salt, Charcoal Dust, Excavation & Earthwork In Soft / Losse Soil And Refilling Pit Chamber With Pcc 1:3:6 Type C1 Using 20 Mm Graded Mechnically Crushed Stone Aggregates , Rcc 1:2:4 Type B-1 Using 20 Mm Graded Mechnically Crushed Stone Aggregates Pit Cover Slab 40Mm Thick Reinforced With 8 Mm Dia Tmt Bars @ 15Cm C / C Both Ways Including Necessary Form Work All As Shown In Electrical Plate No 3 Of Ssr Part-I, Including Testing On Completion At Site Complete All As Specified & Directed. Notes:- ( I ) Any Variation In Length Of Earth Lead And Protection Pipe Of Earth Lead Shall Be Measured & Paid Seperately. ( Ii ) On Testing If The Desired Earth Resistance Is Not Obtained, Earthing Will Be Generated At No Extra Cost, Till The Desired Earth Resistance Is Obtained. ( Iii ) The Chamber Shall Be Constructed Atleast 1.5 Mtr Away From The Earth Electrode. 99 S&F In Replacement 32Mm X 6Mm Gi Strip In Short Pieces On Surface Or In Recess For All Interconnecting Complete All As Specified & Directed. 100 M&L In Replacement Gi Pipe Medium Grade Of Size 80 Mm Bore With All Fittings Such As Socket, Union Etc Complete All As Specified And Directed. 101 Supplying, Laying, Jointing, Testing & Commissioning Under Ground Xlpelt Electric Cable 1100 Volts Grade, Heavy Duty, Pvc Insulatedand Sheathed Armoued Electric Power Cable With Stranded Aluminium Conductor Of Cross Sectional Area 150 Sqmm 4 Core Conforming To Is- 7098 ( Part-I ) 1988 Laid As In Trenches Or Fixed Along The Wall / Pole Through Pipe Etc. Including Taking Down / Out Old Unserviceable Lt Cable Any Size Complete All As Specified & Directed. 102 Description All As Per Boq Item No. 101.00 Here-In-Above But Cross Sectional Area 185 Sqmm 3.5 Core. 103 M&L In Replacement Cable Endjoints Heat Shrinkable Type For Xlpe / Pvc Insulated And Sheathed Aluminium Conductor Cable 1100 Volts 3.5 / 4 Core, Cross Sectional Area 70 Sqmm To 120 Sqmm & Testing After Jointing Complete All As Specified & Directed. 104 Description All As Per Boq Item No. 103.00 Here-In-Above But Cross Sectional Area 150Sqmm To 185Sqmm . 105 Description All As Per Boq Item No. 103.00 Here-In-Above But Cross Sectional Area 240Sqmm To 300Sqmm . 106 Supply & Laying Old Size, Common Burnt Clay, Sub Class B Bricks, Designation 75, Laid Flat & Dryfor Protection Of Electric Cable In Trenches, Adjacent To Each Other, Perpendicular To Central Axis Of Electric Cable Complete All As Specified & Directed. 107 Supply Only White Grase Complete All As Specified & Directed. 108 Disconecting Primary & Secondary Side Cable And Earthing Connections Of Transformers Of Capacity Upto630 Kva , 11Kv / 433 Volts 3 Phase And Shifting To Open Space Within The Yard With The Help Of Crane For Repair / Increase Of Transformer Plinth Foundation Pcc Height And Shifting Back Of Transformer After Proper Curing Of Pcc Work Of Foundation Making Cable Connection All As Per Original Complete All As Specified & Directed.Note:- Pcc / Brick Work Etc. Will Be Measured & Paid Saperately. 109 M&L Consolidated Broken Stone Or Boulders Hardcore Of Gauge Not Exceeding 63Mm, Deposited, Spread And Levelled In Layers Not Exceeding 15Cm Thick Each, Watered And Rammed To A True Surfacecomplete All As Specified & Directed. 110 M&L Brick Work With Sub Class B, Burnt Clay Bricks Of Old Size, Designation 75, Straight Or Curved On Plan Exceeding 6 Mtr Mean Radius, Built In Cement Mortar 1:6 Complete All As Specified & Directed. 111 For Credit Schedule Refer Tender Documents. The Amount Of Credit Schedule Shall Be Deducted From Total Quoted Amount Of Boq To Arrive Contract Sum.
BRR : 5504451
Tender For Repair Maintenance Of Lt Distribution System And Other Misc Allied Works For Pocket A At Jasai Mil Stn Under Ge Army Barmer-- 1 Material and labour for 80 mm dia GI tubing medium grade in repairs incl. accessories for protection of cables on poles/under road crossing complete all as specified and directed. 2 All as per srl item No 01 above but 50 mm dia. 3 All as per srl item No 01 above but 40 mm dia. 4 M&L for excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables, erection of poles, struts/stays, leveling of yard etc not exceeding 10 M² on plan and not exceeding 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed. 5 M&L for clean dry (tibba) sand cushioning to U/G cable and punning for cushioning of cable 8cm below the cable and 15cm above cable all as specified and directed.Note :- Thickness after punning shall not be less then 18 cm. Punned thickness shall only be measured and paid. 6 M&L 40 to 50mm thick rough dressed Jodhpur type stone slab cover 25 to 30 cm wide and not less than 60 cm in length, laid dry abutting each other with gap between adjacent slab not exceeding 10 mm over under ground cable protection complete all as specified and directed. 7 M&L for returning, filling in, including spreading, leveling watering and well ramming in layers n.exc 25 cm in soil complete all as specified and directed. 8 M&L for removing of excavated soil not exc. 50 mtr from starting points complete all as specified and directed. 9 M&L for motorized auguring/drilling under without disturbing road through soil of any type of suitable dia for laying of 40/50/80 mm dia GI tubing pipe by using trenchless method complete all as specified and directed.Note :- Shall be mesured only where re-routing is involed. 10 M&L for Re-routing/relaying of existing LT cable PVC/XLPE insulated aluminium conductor armoured with glavanised steel wire complete of any size and core from any position i.e ground/wall/poles/ culverts etc with protection cover, sand, pipe complete all as specified and directed. Note:- (i) Old cable as obtained shall be re-used. (ii) Old serviceable protection cover, protection pipe and sand obtained under this item shall be reused if found serviceable. (iii) Earth work and any other new items shall be measured and paid separately under relavent items. 11 S&F in repair 4 Sqmm 2 core 1100 volts grade heavy duty cable PVC insulated aluminium solid conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections complete all as specified and directed 12 All as per srl item No 11 above but 6 Sqmm 2 core. 13 All as per srl item No 11 above but 10 Sqmm 2 core. 14 Material and labour for repair to outdoor type double door LT panels/Feeder pillar box by repairing/replacing hinges at site by replacing unserviceable pedestal locks, replacing unserviceable bow handle and connected accessories of front, rear and inner doors by welding, cutting, drilling etc and incl fixing with MS nuts and bolts and repair/ replacing of copper bus bar of various rating suitable along with RYB insulation including cable end terminal aluminium lugs and including one coat of red oxside zink chrome primer on newly replaced steel surfeces and two coats of spray painting using synthetic enamelled paint of approved tint over entire LT panel surfeces (Internal and external) of MS sheets and angles complete all as specified and directed at site. (Note : Copper bus bar and porcelain insulators to be measured and paid under separate Sch A item) 15 Material and labour for replacement of old unserviceable voltmeter/ammeter with panel mounted multi function three phase digital meter of accuracy Cl-1.0 for measuring voltage, current duly painted complete all as specified and directed. Make: Legrand/Schneider/Siemens/ABB 16 Material and labour for replacement of old unserviceable indicators any type with LED based indicating lamps of RYB colour incl disconnecting and connecting of the same complete all as specified and directed. 17 Material and labour for fabrication of copper busbar including, bending cold or hot in any size and shape all directed and including RYB insulation mounted on epoxy cast/polymer glass insulators complete all as specified and directed. 18 Material and labour for fixing of epoxy cast/polymer glass for 1100V grade insulators on the bus bars/panel complete all as specified and directed. 19 Supply and fixing in replacement of 250 Amp, 25 KA, 4 pole, thermal magnetic unserviceable MCCB etc suitable for 415 Volts 3 Phase 4 wire system complete all as specified and directed. Make of MCCB : Legrand/ABB/Indoasian/L&TNote : MCCBs shall be lcu=lcs=100% 20 All as per srl item no 19 above but MCCB, AC, 415 volts, 250 Amp, 25 KA, 4 pole, thermal magnetic 21 All as per srl item no 19 above but MCCB, AC, 415 volts, 200 Amp, 25 KA, 4 pole, thermal magnetic 22 All as per srl item no 19 above but MCCB, AC, 415 volts, 160 Amp, 25 KA, 4 pole, thermal magnetic 23 All as per srl item no 19 above but MCCB, 125 Amp, 415 volts, 16 KA, 4 pole, thermal magnetic 24 All as per srl item no 19 above but MCCB, 100 Amp, 415 volts, 16 KA, 4 pole, thermal magnetic 25 All as per srl item no 19 above but MCCB, 63 Amp, 415 volts, 16 KA, 4 pole, thermal magnetic 26 M&L for demolition of old brocken earth pit chamber and provision of earthing chamber pit made of PCC (1:3:6) type C-1 using 20 mm graded crushed stone aggregate, 40 mm thick precast cover slab of RCC (1:2:4) type B-0 using 12.5mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I complete all as specified and directed. 27 M&L for regular maintenance of existing APFC panel with cleaning of dust inside by blower and cleaning of moving parts/contacts from CT cleaner, tightening of loose parts/ electrical wires, cleaning of contactors, relays and capacitors, junction point, servicing, oiling to cooling fan including testing of APFC relay with necessary setting with CTs/load adjustments to match with the APFC load management system complete with replacement of worn out unserviceable components/burnt wires/ timbles/ lugs of capacity 10 KVAR to 60 KVAR complete all as specified and directed. NOTE :- (i) There are 10 Nos of APFC panel installed at different locations in Mil stn jassai and all the panels are to be maintained for the complete contract period. (ii) The power factor (PF) for all the 17 Nos APFC panel should be in between 0.95 to 0.99, in case the PF is less than the power factor maintain above due to any reason, then the contractor shall liable to pay compenssation equivalent to JVVNL tarrif. (iii) The spare parts shall be of same make and capacity of existing one and shall be measured and paid separately. (iv) Replacement of bolt/nut/screws etc. shall deemed to be included in ther rate quoted. (v) Interval of maintenance shall be according to Engr-In-Charge at site 28 Supply only in replacement of MCB TP 415 Volts 10KA, C curve 10-32 Amps in existing panel of the same make in existing MCB to match with existing holes/surface complete all as specified and directed. 29 Supply only in replacement of MCB TP 415 Volts 10KA, C curve 40-60 Amps in existing panel of the same make in existing MCB to match with existing holes/surface complete all as specified and directed. 30 Supply only in replacement of contactor (capacitor duty type) TP 415 V of capacity 10 to 32 Amps complete all as specified and directed. 31 Supply only in replacement of contactor (capacitor duty type) TP 415 V of capacity 32 to 70 Amps complete all as specified and directed. 32 Supply only in replacement of capacitor 440 volts 50 HZ APP type electric conforming to IS: 13340/13441 & IEC-831-1 of capacity 1 KVAR complete all as specified and directed. 33 Supply only in replacement of capacitor 440 volts 50 HZ APP type electric conforming to IS: 13340/13441 & IEC-831-1 of capacity 5 KVAR complete all as specified and directed. 34 Supply only in replacement of capacitor 440 volts 50 HZ APP type electric conforming to IS: 13340/13441 & IEC-831-1 of capacity 10 KVAR complete all as specified and directed. 35 Supply only in replacement of capacitor 440 volts 50 HZ APP type electric conforming to IS: 13340/13441 & IEC-831-1 of capacity 20 KVAR complete all as specified and directed. 36 Supply only in replacement of voltmeter digital type 0 to 500 volts capacity complete all as specified and directed. 37 Supply only in replacement of Ampere meter digital type 0 to 200 amps capacity complete all as specified and directed. 38 Supply only in replacement of CTs suitable for ampere meter 100/5 Amps Rating complete all as specified and directed. 39 Supply only in replacement of CTs suitable for 200/5 Amps Rating complete all as specified and directed. 40 Supply only in replacement of CTs suitable for 60/5 Amps Rating complete all as specified and directed. 41 Supply only in replacement of APFC relay square flush type with protective device intelligent automatic processor based on electronic controller 6 stages for APFC panel complete all as specified and directed. 42 Supply only in replacement of APFC relay square flush type with protective device intelligent automatic processor based on electronic controller 8 to 14 stages for APFC panel complete all as specified and directed. 43 S&F in replacement of selector switch for voltmeter & Amp meter of existing suitable size complete all as specified and directed. 44 M&L for spray painting to existing LT panel board/Kisok of any size after scrapping the existing paint and two coats of synthetic enamelled paint over a coat of red oxide primer complete all as specified and directed. 45 Supply only Copper Lugs suitable for 6 sqmm copper cable. 46 Supply only Copper Lugs suitable for 10 sqmm copper cable. 47 Supply only Copper Lugs suitable for 16 sqmm copper cable. 48 Supply only Copper Lugs suitable for 25 sqmm copper cable. 49 Supply and lay cable in replacement XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 Volt grade with stranded aluminium conductor of size 10 sqmm 2 core complete all as specified and directed. Make : Finolex/Havells/KEI. 50 Supply and lay cable in replacement XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 Volt grade with stranded aluminium conductor of size 25 sqmm 4 core complete all as specified and directed. Make : Finolex/Havells/KEI. 51 Supply and lay cable in replacement XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 Volt grade with stranded aluminium conductor of size 70 sqmm 3.5 core complete all as specified and directed. Make : Finolex/Havells/KEI. 52 Supply and lay cable in replacement XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 Volt grade with stranded aluminium conductor of size 95 sqmm 3.5 core complete all as specified and directed. Make : Finolex/Havells/KEI. 53 M&L for outdoor jointing kit suitable for 25 to 50 sqmm 3.5/4 core XLPE/ PVC Cable 1100 volts grade, heat shrinkable type for indoor/ outdoor applications including preparing ends of cable complete all as specified and directed. (Make: Denson, Raychem) 54 All as per srl item no 53 above but for 70 to 250 sqmm 3.5 core. 55 M&L for dismantling of broken U/S existing earthing with galvanised steel strip/wire complete including removing of PCC from site. 56 M&L for bore well earthing by drilling bore with bore machine for poles and other matchinery/eqpt using GI pipe heavy duty 50 mm dia as earth electrode driven up to a depth of 50 meters below ground level, duly made holes at 20 cm intervals, along the length of GI pipe and providing the charcoal salt mixture incl GI pipe 150mm dia light grade as protection up nto a depth of 12 meters and GI strip of 32x6 mm so as to acheive desired earth results including testing and commissioning complete all as specified and directed. (Earth strip of size 32x6mm upto a length of 7.5m is deemed to incl in this item rate). 57 M&L for earthing complete with galvanized steel earth plate electrodes 600mmx600mmx6mm thick buried directly in ground earth (earth pit not less 2.25 m deep below ground level) with top edge of the plate not less then 1.5 mtr below normal ground level connected to galvanised iron earthing strip 32mm x 6mm thick by means of bolt nuts check nuts and washers of galvanized iron or steel all as specified & shown in electrical plate No.3 of MES SSR part-I 2010 connected to earth test point as specified and testing on completion including provision of 40 mm dia light grade pipe up to 7.5 mtr length as protection & watering pipe shall be 20 mm bore medium grade including all excavation & earth work in any type of strata incl PCC pit (1:3:6) type C-1 with RCC cover including charcoal, salt, funnel, complete all as specified and directed. Note : Rate included for excavation & earth work in any type of strata as shown in electric plate no-3 in SSR Part-I. 58 M&L for dismantling and disconnecting the exsisting unserviceable LT panel boards of any type in non repairable condition complete all as specified and directed. 59 Supply, install, testing and commissioning of LT panel board, outdoor type, floor mounted, factory made (CPRI approved) suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with copper bus bars of rating current density 1.6 (400 amps) duly insulated by insulation of RYB colour 400 Amps rating mounted on porcelain insulators. The panels shall be factory made, double door, made out of 3.15 mm thick MS sheet totally enclosed dust, vermin and rust proof front operated, front and rear opening with locking arrangement fixed with MS angle iron frame of size 40X40X5 mm including embedding the panel in PCC platform and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 hinges to panel doors and locking arrangement as desired complete all as specified and directed and comprising of the following:-(A) INCOMING(a) MCCB 4 Pole 415 Volts 36 KA 250 Amp rating thermal magnetic release type (Icu=Ics=100%) -01 No(b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No.(c) Panel mounted multi function voltmeter & ammeter of accuracy CL-1.0 rating including CT - 01 No(B) OUTGOING(a) MCCB 4 Pole 415 Volts 25 KA 160 Amp rating thermal magnetic release type (Icu=Ics=100%) -01 Nos(b) MCCB 4 Pole 415 Volts 25 KA 100 Amp rating thermal magnetic release type (Icu=Ics=100%) -02 NoMake : Legrand/ABB/Schneider 60 Supply, install, testing and commissioning factory made LT feeder pillar (Kiosk) box made out of CRCA sheet of 3.15mm thick, 200A rated, of size 0.45 x 0.45 x 0.45 mtr, outdoor canopy type, CPRI approved, floor mounted, dust and vermin proof, front and rear operated door with necessary locking arrangement made of 50 x 6mm MS angle iron frame work and duly painted with two coats of powder coated paint of approved shade after seven tank treatment process both internally and externally. The panel shall be suitable for 415 Volts, 50 HZ, 3 Phase 4 wire system and shall be complete with suitable capacity screwed copper bus bar (200 Amp rating) with suitable size bolt and nuts, thimbles glands as per existing structure complete all as specified and directed. 61 Material and labour cement concrete (1:2:4) type B -1 using 20 mm graded stone aggregate for pedestal of poles/copping including necessary frame work, fair finishing to exposed surfaces using extra cement complete all as specified and directed. 62 Material and labour for cement concrete (1:3:6) type C -2 using 40 mm graded stone aggregate for foundation of pole/struts/stay assembly etc complete all as specified and directed. 63 Supply and errect in replacement steel tubular swaged poles type 410 SP-31 (9.0 metres long) with cast iron base plate and finial taper plug, bolts, nuts & screws complete all as specified and directed.Note: - (i) Excavation and earthwork, PCC shall be measured and paid separately in relevant item.(ii) Painting with two coats of black bituminous paint throughout internally and externally upto plating depth and the remaining external complete pole portion shall be painted with silver colour in two coats over a red oxide primer 64 M&L for disconecting and reconecting of burnt LT XLPE cable from panel to OH conductor on pole/ panel/equipment including removing of faulty part of cable, preparation of cable for connection, suitable Al lugs, nut bolts, glands, GI pipe etc and directed on site. Note: (i) The cost of earth work for taking out LT cable loop and refiling will deemed to be included in above quoted rate. (ii) GI pipe to be measured under separate Sch A item mentioned. 65 Material and labour in replacement of ACSR conductor straightening properly on insulators and binding with aluminum taps/binding wire/conductor jumper etc complete all as specified and directed. 66 M&L for dismantling of cross arms (Clamp, nut bolts ), carefully from site all as specified and directed. 67 Material and labour for steel structure, cross arms bracing supports, clamps, back plates of any type, section incl. nuts, bolts, washers, welding, bending cold or hot in any size and shape all directed Including two coats of aluminium paints over a coat of red oxide primer incl preparation of surface complete all as specified and directed. 68 M&L for trimming and pruning of one tree complete with cutting of all branches of any dia but not exceeding 75 mm up to a safe distance from the over head lines and disposal of branches/bushes to a distance and clearing the site complete all as specified and directed.NOTE:- 1. The necessary man power, tool & plant, cutting tools and JCB required for cutting/pruning of branches is deemed to incl in the rate quoted for the job. 2. Proper shut down tol be taken care by the authorised rep only. 69 Material and labour for preparation of old painted surface and ZEBRA painting of PCC/steel poles 9/11 m long alongwith road upto 1.5 m height from pedestal, with two coats of enamel synthetic paints in 30 cm height incl painting of pole coping with black paint and writing pole No. complete all as specified and directed. 70 M&L for painting of steel tubular pole/rail pole upto 9 mtr long with two coats of enamel synthetic silver paints over a one coat of red oxide complete all as specified and directed. 71 Material and labour for preparation of old painted surface for steel structure, cross arms bracing supports, clamps, back plates of any type, section incl. nuts, bolts, washers, pipes mounted on PCC/steel poles 9/11m long alongwith road with two coats of enamel synthetic paints complete all as specified and directed. 72 Material and labour for writing pole number of minimum size 10 cm height with black paint over base of yellow paint on PCC/steel poles of LT/HT supply complete all as specified and directed. 73 M&L for dismantling of insulators any type any size from existing poles complete all as specified and directed. 74 Supply and fix pin type porcelain insulator, vitreous white brown or green including one galvanised mild steel spindle, two GI washer and GI nuts 100 mm height 65 mm dia for 1100 volts grade complete all as specified and directed. 75 Supply and fix shackle type, porcelain, vitreous, white, brown or green insulator 1100 volt grade 75 mm in height and 90 mm dia including galvanised mild steel straps of size 31 x 3 mm, insulator bolt of 12 mm dia, washers and nut complete all as specified and directed. 76 M&L in replacement for stay assembly complete with 230x230x 6 mm thick plate and 16 mm dia stay rod all as shown in elect plate No-1 of SSR-part-1 including stay wire of size 7/4mm dia and suitable loop insulator of appropriate size complete all as specified and directed. Note : Rate quoted is deemed to be included of excavation in any type of soil, PCC for stay and dismantling of old stay assy. 77 M&L in replacement of cradles, hexagonal/rectangular, fabricated with galvanised steel wire 3.15 mm or 4 mm dia complete all as specified and directed. 78 S&F in repair name board acrylic type (280mm x 400mm) of incoming and outgoing feeder, caution board etc with radium glow sign reflector type on acrylic board incl clamp of suitable size, nut, bolt etc complete all as specified and directed. 79 Supply and laying of 12.5 mm thick stone aggregate size in E/M installations complete all as specified and directed. 80 M&L for removing wild grass, vegetation, creepers, etc climbing up towards the poles and stay including cleaning bottom surface area of pole & stay not less than 1m x 1m by surface dressing of earth and inside the fencing of out door installations complete all as specified and directed.
BRR : 3721802
Tender For Repair Maintenance Of Street Light Security Light Including Allied Work Under Allenby Ph Area Under Ge Utility Ambala Cantt; 1 Supply & Fixingin Replacement Of Integral Led Flood Light Luminaries 100 Watts Consisting Of Suitable Number Of Leds Andmounted On Mcpcb High Pressure Die Cast Aluminium Housing With Sealed Toughened Glass Cover With Secondary Optics Lens, Ip 66 Protection Suitable For Mast Light Mounting, 5700K, Led Efficiency >130 Lm / Watt And System Efficiency 110 Lm / W , 240 Volts Ac, 50 Hz, Cri>70% Operating Voltage Range 160 V-270 V, Power Factor> 0.95, Working Temperature Range -10ºc To 50ºc, Built In Surge Protection Of More Than 10 Kv , Confirm The Tests From Auth Labs :Lm79 & Lm 80, Incl Proper Fixing And Testing Of Flood Lights On 9 / 11 Mtr Long Steel Tubular Pole And Provide Facility Of Power Supply Shall Be Provide As Suitable For Maint Work Of Light Fittings Incl Make Proper Connection Of New And Existing Light Fittings Complete With Cutting , Welding , Drilling Holes, Nut Bolts, Washer Complete All As Specified & Directed. 2 All As Per Item Sr No 1 Here But For 150 Watts Led Luminaires Complete All As Specified & Directed 3 All As Per Item Sr No 1 Here But For 200 Watts Led Luminaires Complete All As Specified & Directed 4 Supply & Fixingin Replacement Ofled Street Light Fitting45 Watts Made Up Of Pressure Die Cast Aluminium Housing With High Efficiency Leds As Lighting Source And Lens Embedded Toughened Glass Having Top Opening Seperate Driver Compartment With Ip 66 Protection And Impact Resistance Of Ik07 Consisting Of Suitable Number Of Leds With Sealed Toughened Glass Cover, 5700K, Led Efficiency >110 Lm / Watt And System Efficiency 110 Lm / W , 240 Volts Ac, 50 Hz, Cri>70% Operating Voltage Range 140 V-270 V, Power Factor> 0.95, Mains Current 0.270A, Working Temperature Range-10ºc To 50ºc, Built In Surge Protection Of More Than 10 Kv, Better Optics For Uniform Distrubution With Multiple Leds Not Less Than 2 Watt Each And Having Optical Grade Polycarbonate Lens With All Accessories , Suitable For Side Entry, Pole Mounting With Bracket Arm Od 40 Mm, Recommended Mounting Height With Suitable Inground Reinforcement Is 8 Mtrs, Confirm The Safety Test As Per Is 15885 Part-2 From Auth Labs :Lm79 & Lm 80, Incl Proper Fixing And Testing Of Street Lights On 9 / 11 Mtr Long Steel Tubular Poleincl Make Proper Connection Of New And Existing Light Fittings Complete With Cutting , Welding , Drilling Holes, Nut Bolts, Washer Complete All As Specified And Directed. Note :-Pvc Heavy Duty Conduit Pipe Along With 3 / 1 Run Of 1.5 / 2.5 Sqmm Pvc Insulated Unsheathed / Sheathed Copper Multistranded Conductor From Mcb Box To Streetshall Be Measured And Paidfor Separately. 5 All As Per Item Sr No 4 Here But For 70 Watts Led Luminaires Complete All As Specified And Directed. 6 All As Per Item Sr No 4 Here But For 90 Watts Led Luminaires Complete All As Specified And Directed. 7 Dismantling And Taking Down Security Light, Street Light, Hanger Light, Flood Light And High Mast Lights Of Any Type At Any Height Fittings Such Ashpsv / Hpmv / Mh / Led Light Of 48 Watt / 60 Watt / 70 / 72 Watt / 90 Watt / 120 Watt / 150 Watt / 200 Watt And 300 Watt Of Any Make Etc. Ac 230 Volts Any Wattage From Pole / Wall Roof Top / Hanger Roof Including Washing / Cleaning Of Perplex Cover Inspection For Location Of Faultand Replacing Of Defective Spare / Parts Required For Smooth Functioning, Tightening Of Electric Connection, Assembling And Reconnecting All As Per Site Requirment Complete All As Specified And Directed. Note: Defective Spare / Part Of Relevant Light Fitting Shall Be Measured And Paid Separately Under Relevant Item As Supply Only. 8 Supply Only Led Electronic Driver / Adaptor / Spdfor40-48 Watt Ledsecurity Light Fitting Of As Per Existing Makecomplete All As Specified & Directed. 9 Supply Only Led Electronic Driver / Adaptor / Spdfor60 Watt Ledsecurity Light Fitting As Per Existing Make Complete All As Specified & Directed. 10 Supply Only Led Electronic Driver / Adaptor / Spdfor70 / 72 Watt Ledsecurity Light Fitting As Per Existing Makecomplete All As Specified & Directed. 11 Supply Only Led Electronic Driver / Adaptor / Spdfor90 Watt Ledsecurity Light Fitting As Per Existing Makecomplete All As Specified & Directed. 12 Supply Only Led Electronic Driver / Adaptor / Spdfor 100 / 120 Watt Led Flood Light Fitting As Per Existing Makecomplete All As Specified & Directed. 13 Supply Only Led Electronic Driver / Adaptor / Spdfor150 Watt Ledflood Light Fitting As Per Existing Make Complete All As Specified & Directed. 14 Supply Only Led Electronic Driver / Adaptor / Spdfor200-300 Watt Ledflood Light Fitting As Per Existing Makecomplete All As Specified & Directed. 15 Labour Only For Trimming Of Tree Branches Oh Lines Of Ht / Lt & Maintain Approaching Minimum Clearance Of 3 Mtrfrom Branches. Proper Shutdown Will Be Taken And Maintained In The Register Complete All As Specified And Directed. 16 Supply & Fixing In Replacementof Automatic Street Light Control Switch With Infrared Sensor Based Nature Switch & Voltage Monitoring System ( Vms ) . Three Phase, 25 Amps Per Phase, Mcb Rating 32 Amp, Max Load 8-12 Kw Incl Circuit Copper Wire 10 Sq.Mm.Nature Switch Operation Should Be Based On Natural Light Lux Level. Required Illuminance Level For Switching On Is = 60 Lux And For Switching Off = 10 Lux. The Sensor Should Also Have Part Night Operation Facility Of Min. 4 To Max. 12 Hrs. Vms Should Have Adjustable Over & Under Voltage Trip Level And Protection Against Phase Loss, Neutral Loss & Phase Reverse. The Sensor & Vms Along With Suitable Power Contactor ( S ) And Incoming-Outgoing Mcbs Should Be Enclosed In A Pole / Wall Mountable Enclosure Made Of Rust Proof, Electric Shock Proof, Termite Proof And Fr Grade Smc Junction Box Conforming To Ip54. The Circuit Should Also Have Provision For Manual Operation ( I.E. By-Pass Option For Both Sensor ( Ns-02 ) And Vms ) . Madel :Swadeep-02Ec-8Kw3p-Vms Complete All As Specified And Directed.Note ( I ) S S Nut Bolts, Clamp For Fixing On Poles / Wall Are To Be Included In Quoted Rates. ( Ii ) The Sensor Must Have The Warranty Of Min Of 2 Years. ( Iii ) The Test Certificate And Warranty Certificate Must Be Provided By Supplier. ( Iv ) Cost Of Marking Description On The Box Is Included In Quoted Rate. 17 Supply & Fixing In Replacementof Automatic Street Light Control Switch With Infrared Sensor Based Nature Switch & Voltage Monitoring System ( Vms ) . Single Phase, 25 Amps Per Phase, Mcb Rating 40 Amp, Max Load 5-8 Kw Incl Circuit Copper Wire 10 Sq.Mm.Nature Switch Operation Should Be Based On Natural Light Lux Level. Required Illuminance Level For Switching On Is = 60 Lux And For Switching Off = 10 Lux. The Sensor Should Also Have Part Night Operation Facility Of Min. 4 To Max. 12 Hrs. Vms Should Have Adjustable Over & Under Voltage Trip Level And Protection Against Phase Loss, Neutral Loss & Phase Reverse. The Sensor & Vms Along With Suitable Power Contactor ( S ) And Incoming-Outgoing Mcbs Should Be Enclosed In A Pole / Wall Mountable Enclosure Made Of Rust Proof, Electric Shock Proof, Termite Proof And Fr Grade Smc Junction Box Conforming To Ip54. The Circuit Should Also Have Provision For Manual Operation ( I.E. By-Pass Option For Both Sensor ( Ns-02 ) And Vms ) . Madel : Swadeep-02Ec-5Kw1p-Vms Complete All As Specified And Directed.Note ( I ) Nut Bolts, Clamp For Fixing On Poles / Wall Are To Be Included In Quoted Rates. ( Ii ) The Sensor Must Have The Warranty Of Min Of 2 Years. ( Iii ) The Test Certificate And Warranty Certificate Must Be Provided By Supplier. ( Iv ) Cost Of Marking Description On The Box Is Included In Quoted Rate. 18 Excavation In Trenches Not Exceeding 1.5 Metre Wide And Not Exceeding 1.5 Metre In Depth For Foundation, Shafts, Man Holes, For Under Ground Cable / Erection Of Poles, Stays, Locatingfault Of Lt Cable And Stay Assembly Etc Not Exceeding 10 Square Metre On Plan And Getting Out In Any Type Of Soil Including Dressing / Trimming Of Sides And Leveling, Grading And Ramming Of Bottom Of Excavation Complete All As Specified And As Directed. 19 All As Per Ser Item No 18.00 Here In Before But Depth Exceeding 1.5 Metre And Not Exceeding 3.0 Metre Complete All As Specified & Directed. 20 Returning, Filling In, Soil, Including Spreading, Levelling, Watering And Well Ramming In Layers Not Exceeding 25Cm Thick Each Layer Complete All As Specified And Directed. 21 Removing Excavated Material / Soil To A Distance Not Exceeding 50M And Depositing Where Directed At A Level Not Exceeding 1.5M Above The Starting Point Complete All As Specified And Directed. 22 Material And Labour For Sand Cushioning To Cable With A Layer Of Sand 8 Cm Thick Before Laying The Cable And 15 Cms Thick After Laying The Cable ( Punned Down To 18 Cms Depth After Laying And Stretching Of Cable ) Complete All As Specified And As Directed. 23 Supply And Lay Bricks, Common Burnt Clay, Sub Class B, Old Size, Laid In Vertical Direction To Cable As Cable Protection Complete All As Specified And As Directed. 24 All As Per Ser Item No 23.00 Here In Before But Except Bricks, All As Specified And Directed.Note:- Old Bricks Retrieved From Ser Item No 28.00 To 35.00 Here In After Shall Be Re-Used. 25 Material & Labour For Cement Concrete In Foundations, Filling And Mass Concrete Pcc As Foundation To Poles, Type D2, 1:4:8 Using 40 Mm Graded Stone Agregate As Foundations To Poles Complete All As Specified And Directed. 26 Material & Labour For Cement Concrete, Filling And Mass Concrete, Pcc Type C2, 1:3:6 Using 20 Mm Graded Aggregate Complete All As Specified & Directed. 27 Material & Labour For Cement Concrete As Coping To Poles, Pcc Type B1, 1:2:4 Using 20 Mm Graded Stone Agregate As Foundations To Poles A Complete All As Specified & Directed. 28 Disconnecting & Taking Out Defective Underground Cable From Trenches, Pole, Pipe, Floor, Wall Etc And Locate The Fault, Rectify The Defect And Relaying The Xlpe Cable Underground Pvc Insulated And Overall Sheathed Aluminum Conductor Heavy Duty 1100 Volts Including Connecting And Testing For Any Size Complete All As Specified & Directed. ( Excavation / Earth Work & Sand Cushioning, Bricksandjoint Shall Be Measured & Paid For Separately ) . 29 Supply, Laying, Connecting And Testing Xlpe Underground Cable Insulated, And Overall Sheathed With Aluminium Conductor Heavy Duty 1100 Volts Grade10 Sqmm 4.0 Core Including Aluminium Thimbles Laid In Trenches / On Pole / Road Crossing Or Passing Through Existing / New Pipe Under Road Crossing Clamping On Wall Etc Including Taking Out Existing U / Scable Complete All As Specified & Directed.Note : ( I ) Earth Work, Sand, Bricks Removing, Returning Filling Will Be Paid Seperately. ( Ii ) Cost Of Laying Electrical Cable Through New / Existing Pipe Under Road, Buildings, Railway Tracks, Highways Are Incl In The Quoted Rates ( Iii ) All Equiments, Machinery Or Tool If Required For Laying Electrical Cable Through New / Existing Pipes Are Provided By The Contractor Without Any Extra Cost. 30 All As Per Item Ser No 29 Here In Before But For 4 Core 16 Sqmm Complete All As Specified & Directed. 31 All As Per Item Ser No 29 Here In Before But For 3.5 Core 25 Sqmm Complete All As Specified & Directed. 32 All As Per Item Ser No 29 Here In Before But For 3.5 Core 35 Sqmm Complete All As Specified & Directed. 33 All As Per Item Ser No 29 Here In Before But For 3.5 Core 50 Sqmm Complete All As Specified & Directed. 34 All As Per Item Ser No 29 Here In Before But For 3.5 Core 70 Sqmm Complete All As Specified & Directed. 35 All As Per Item Ser No 29 Here In Before But For 3.5 Core 95 Sqmm Complete All As Specified & Directed. 36 Supply And Fixing In Replacement Of Fabrication Of Kiosk Box Made Out Of Fibre Material Complete With Tpn , Aluminium Bus And Suitable For One Number Mcb ( Sp ) Including One No Mcb ( Sp ) 6 Amps 240 Volts With Glands For Incoming & Out Going Cable Including Fixing Of Flat Iron Clamps Of Size 20X4mm On Pcc / Steel Tubular Polecomplete All As Specified & Directed.. Make: Havells / Sintex. 37 Supply And Fix In Replacement Of Mcb Sp 6-32 Amps, 240 Volt, 10 Ka B Curveincluding All Accessories Complete All As Specified And Directed. 38 Supply And Fix In Replacement Of Mcb Dp 16-40 Amps, 240 Volt, 10 Ka B Curveincluding All Accessories Complete All As Specified And Directed. 39 Supply And Fix In Replacement Of Mcb Tpn 32-63 Amps, 240 Volt, 10 Ka B Curveincluding All Accessories Complete All As Specified And Directed. 40 Supplying And Fixing In Replacement Of 1100 Volts Grade Heavy Duty Cable Pvc Insulated Aluminium Conductor, Served With Inner Sheathing Of Pvc Tape And Overall Pvc Sheathed In Service Connections Suspended By Insulating Hangers Not More Than 1 Metre Apart Including 4Mm Suspension Wire, One Twin Core Cable Flat Or Circular Of Size 10 Sqmm 2 Core Complete All As Specified And Directed. 41 Supply And Fixing In Replacement Or Passing Through Pvc Conduit Pipe Of 1100 Volts Grade Heavy Duty, Pvc Insulated Round 3 Core 1.0 Sqmm Copper Cable Including Electrical Connection Suitable Size Of Lugs, Nuts And Bolts Complete All As Specified And Directed. 42 Supply And Fixing In Replacement Or Passing Through Pvc Conduit Pipe Of 1100 Volts Grade Heavy Duty, Pvc Insulated Round 3 Core 2.5 Sqmm Copper Cable Including Electrical Connection Suitable Size Of Lugs, Nuts And Bolts Complete All As Specified And Directed. 43 Supply And Fixing In Replacement Or Passing Through Pvc Conduit Pipe Of Single Core Pvc Unsheathed Multi Stranded Copper Cable ( Frls ) 1.5 Sqmm Nominal Cross Sectional Area 1100 Volts Conforming To Is 694 Including Electrical Connection Suitable Size Of Lugs, Nuts And Bolts Complete All As Specified And Directed. 44 Supply And Fixing In Replacement Or Passing Through Pvc Conduit Pipe Of Single Core Pvc Unsheathed Multi Stranded Copper Cable ( Frls ) 2.5 Sqmm Nominal Cross Sectional Area 1100 Volts Conforming To Is 694 Including Electrical Connection Suitable Size Of Lugs, Nuts And Boltscomplete All As Specified And Directed. 45 Supply And Fixing In Replacement Of Rigid Non-Metallic Pvc Conduit Of Dia 20 Mm Exclusive Of Boxes ( Junction / Terminal ) But Inclusive Of All Tees, Bends, Elbows, Reducers, Bell Mouth Tube Ends And Fixing Accessories Such As Couplers, Lock Nuts, Saddles, Pipe Hooks Etc Complete All As Specified & Directed.Note: Pvc Pipe Will Be Clamped At Three Position On Pole And Cost Of Clamp, Nut, Bolts Etc Are Incl In Quoted Rates Complete All As Specified And Directed. 46 Supplying And Fixing In Replacement Oflight Gradegalvanised Mild Steel Pipe 80Mm Bore With All Fittings, Laid Under Roads, Drain, Paths, Fixed To Poles / Walls With Suitablemild Steel Clamps, Bolts, Nuts And Washerscomplete All As Specified & Directed.. Note:- Excavation & Earth Work Shall Be Measured And Paidfor Separately Under Appropriate Item Of This Schedule. 47 All As Per Item No 46 Here-In-Before But Of Size 40 Mm Bore Complete All As Specified & Directed. 48 Supply & Fixingin Replacement Of Bracket Made Out Of Gi Tubing Single Piece Not Welded, Bended At Proper Angle Of Size 40Mm Dia, Light Grade 1.5 Mtr Long Including Painting With Aluminium Paint Over One Coat Of Red Oxide Primer To The Bracket Complete All As Specified And As Directed. 49 Supply & Fixing In Replacement Of Ms Clamp Suitable For Holding Street Light Bracket On Steel / Pcc Polemade Out Of 40 Mm X6 Mm Thick Flat Iron With M.S Nuts Bolts 50 Mm Long 10 Mm Dia-3 Nos With Flat Washer 3Mm Thick -02 No For Each Includingpainting With Aluminium Paint Over One Coat Of Red Oxide Primer To The M.S Clamps Complete All As Specified & Directed. 50 Supply, Fix And Erection Of Prestressed Concrete Pole 9.0 Mtr Long In True Vertical Position 102X172 Mm At Top 102X279 Mm At Bottom Class-10 Incl Providing Black And White Strips With Synthetic Enamel Paint 30 Cm Each Alternate Upto 1.5 Mtr Including 2 Bands Of Radium Tape Of 2 Width Greeen & Red Colour Above The Coping Of Pole Starting With Black Strip Including Dismantalling And Taking Down Old Unsv Pole Complete All As Specified & Directed.. Note ( I ) Earth Work And Pcc Shall Be Measured And Paid Seperately ( Ii ) Description As Per Direction Of Engineer-In-Charge Will Be Printed On Each Pole Without Any Extra Cost. 51 Supply, Fix Anderection Of Steel Tubular Swaged Poles Complete With Cast Iron Base Plate, Finial Taper Plug, Bolts, Nuts And Screws As Specified Type 410 Sp-31, 09 Meter Long, Providing Synthetic Enamel Aluminium Paint Over One Coat Of Red Oxide And Black And White Strips With Synthetic Enamel Paint 30 Cm Each Alternatively Upto 1.5 Mtr Including 2 Bands Of Radium Tape Of 2 Width Greeen & Red Colour Above The Coping Of Pole Starting With Black Strip, Including Dismantalling And Taking Down Old Unsv Pole Complete All As Specified & Directed.. Note ( I ) Earth Work And Pcc Shall Be Measured And Paid Seperately ( Ii ) Description As Per Direction Of Engineer-In-Charge Will Be Printed On Each Pole Without Any Extra Cost. 52 Supply And Fix Inreplacementof Lithium Based Energy Efficient Integrated Solar Street Light Of 32 Watt” In Single Frp Body With Duly Polyurethane Coating ( Camouflage Color ) , Encases With Monocrystalline Solar Pv Panel Of 64 / 66Wp , Lithium Battery 11.1 / 12.8V, 33.0Ah With Inbuilt Bms, Ip 65, High Brightness W-Led ( 160-180Lm / Watt ) Lamp With Aluminum Reflector For Better Light Distribution , Cri >70, Color Temperature 5700°K - 6500°K, Microcontroller Based Charge Controller Cum Driver, Automatic Dimming Function ( First Four Hours At Full Brightness & Rest Of The Time At Lower Light Level With Pir Motion Sensor ) , Dusk To Dawn Operation, Suitable To Working Temperature: ( - ) 10°C To ( + ) 55°C, Weight Not More Than 16-18Kg With Adjustable Ms Clamp Suitable For Pole / Wall Mounting Etc Complete As Required. Protections: Short Circuit, Overload, Reverse Polarity And Battery Protections. Firm Should Provide Vital Parameters Test Report From Nabl Accredited Lab And Should Be Of Made In India With Ce & Rohs Compliant Including Tubular Pole 6 Mtr Height With Bottom Base Plate 200X200x12 Mm , Outdoor Dia Not Less Than 65 Mm With Heavy Duty Gi Pipe Or Steel Thickness 3Mm And Suitable Arrangement To Mount Solar Light As Directed On Pole Including Foundation Pcc 1:3:6 Type C-1Using 20Mm Graded Crushed Stone Aggregate And Erection As Per Manufacturer Drawing, Providing Synthetic Enamel Aluminium Paint Over One Coat Of Red Oxide Primer Complete All As Specified And Directed Make:- Axxon ( Axn-32W ) Or Equivalent Of Phillips / Bajaj / Wipro / Havells 53 Dismantling And Taking Down Old Unsv Lt Feeder Pillar And Supply, Installing, Testing & Commissioning In Replacement Of Outdoor Type Cubical Lt Feeder Pillar Panel Box Size 1.0Mx0.8Mx50cm With Double Door Type Cubical Panel Board Outer Shell Made Out Of3.15 Mm Thick Crca Sheet And Inner Shell Made Out Of 2 Mm Thick Crca Sheet And Ms Angle Section 50X50x6 Mm Mounted On Pcc 1:2:4 Type B-1 Platform 60 Cm Aboveand 45 Cm Below The Ground Level, Frame Factory Fabricated With Front And Rear Openable Double Door System And Cable Alley ( Each Door Hinged With Body At 3 Places With Body And Hinges Should Be Welded With Body And Door ) Lockable / Openable By Keyshaving Chromium Plated 19 Mm Dia Fancy Lock, “U” Type Gasket Shall Be Used To Make The Outer Shell Completely Vermin Proof Suitable For 3 Phase 4 Wire 415 Volt, 50 Hz, Incl Aluminium Bus Bar Of 200 A , Tested At Factory Approved From Cpri Factory Fabricatedhaving Modern Fabrication And Testing Process Followed By Powder Coat Painting Having Thickness Not Less Than 100 Microns Provided With Suitable Gasket To Make It Dust / Vermin Proof And General Construction Confirming To Is:61439 / 2011Part-1 Andpart -2 Type Test Certificate With Not Less Thanip-56And Breaking Capacity 65 Ka Comprising Of The Following :-A ) Incoming Mccb100 Amps, 16 Ka 4 Pole 415 Volts Ac, -01 No. ( B ) Outgoing Mccb63 Amp, 10 Ka, 4 Pole 415 Volt Ac, -02 Nos. ( C ) Outgoing Mcb32 Amp, 10 Ka , Tpn 415 Voltac -02 Nos ( D ) Ryb Indication Led Type, 22.5 Mm Dia, Protected With Mcb Sp 2 Amp Showing 3 Phase Supply -03 Nos ( E ) Digital Ammeter Of Range 0-200 A, Auxiliary Voltage 230 Volts With Selector Switch -01 Nos ( F ) Volt Meter Of Range 0-500 Volts, Auxiliary Voltage 230 Volts With Selector Switch -1 No ( G ) Misc Items Like Screws, Cable Tie, Copper Cable 1.5 / 2.5 Sqmm, Cabe Lugs, Sleeves, Glands Etc Complete Are Included In Quoted Rates. 54 Dismantling And Taking Down Old Unsv Lt Feeder Pillar And Supply And Installing, Testing & Commissioningin Replacement Of Factory Fabricated Outdoor Type Feeder Pillar Board Of Size 1.0Mx0.8Mx0.50 Mtr , Outer Shell Made Out Of3.15 Mm Thick Crca Sheet And Inner Shell Made Out Of 2 Mm Thick Crca Sheet And Ms Angle Section 50X50x6 Mm Mounted On Pcc 1:2:4 Type B-1 Platform 60 Cm Aboveand 45 Cm Below The Ground Level, Frame Factory Fabricated With Front Openable Double Door System And Cable Alley ( Each Door Hinged With Body At 3 Places With Body And Hinges Should Be Welded With Body And Door ) Lockable / Open Ablewith Arrangement Of Pad Locking On Door01 No Of Pad Lock Of Three Keys Shall Be Used To Make The Outer Shell Completely Vermin Proof Suitable For 3 Phase 4 Wire 415 Volt, 50 Hz, Tested At Factory Approved From Cpri Factory Fabricatedhaving Modern Fabrication And Testing Process Followed By Powder Coated Painting After 7-Tank Pre Treatement Control & Power Wiring With Suitable Size Of Copper Conductor Along With Suitable Gasket To Make It Dust / Vermin Proof And General Construction Confirming To Is:61439 / 2011Part-1 Andpart -2 Type Test Certificate With Not Less Thanip-56And Breaking Capacity 65 Ka Comprising Of The Following :- ( A ) Mccb 160 Amps Tpn, 25 Ka -01 No ( B ) Mccb 40Amp Tpn 4 Pole - 04 Nos ( C ) Aluminium Busbar Of Capacity 200 Amps With Colour Coated Heat Shrinkable Sleeve And Suitable Hole For Out Going Connection - Set Of Four. ( D ) Misc Items Like Screws, Cable Tie, Copper Cable 1.5 / 2.5 Sqmm, Cabe Lugs, Sleeves, Glands Etc Complete Are Included In Quoted Rates 55 Notes For Item Sr No.53 To 54 ( I ) The Quoted Rate Shall Include Minor Items Such As Lugs, Nuts & Bolts, Washers, Top Insulators, Sleeves, Provision Of Extra Holes In Bus Bar Etc. ( Ii ) All Internal Wiring Shall Be Done With Suitable Size Of Pvc Insulated Solid Copper Conductor Frls Cable Conforming Tois-694. ( Iii ) Panel Drawing Shall Be Got Approved Before Placing Of Orderfrom Engr-In-Charge / Ge. ( Iv ) The Bus Connection For Cable From Main Bus Bar To Outgoing Mccb Will Be Connected Through Suitable Rating Bus Bar Strip Type Duly Insulated. ( V ) Cable Will Be Entered In Panles Through Gland. ( Vi ) Cost Of Marking Description And Matter On The Front Door As Specified And Directed By Engr-In-Charge Is Incl In Quoted Rate. 56 Material And Labour In Replacement Of Broken Earth Pit Of Size 300X300x300 Mm Madeof Pcc 1:2:4 Type B1 Using 20 Mm Graded Crushed Stone Aggregate, And Earth Pit Cover Made Out Of Rcc 1:2:4 Type B1, Cover Reinforced With 8 Mm Dia Tmt Bars @ 100 Mm Centre To Centre Both Ways With Handle Made Out Of 8 Mm Dia Bar, Watering Arrangement With Funnel And Wire Mesh And Including Reconnecting Of Earth Lead Of Any Type With New Nuts, Bolts And Washers As Required At Site With Testing Result Complete All As Specified & Directed.. 57 Material And Labour In Replacement Of Stay By Tightening Of Stay Wire After Untying The Conductor Spans From The Poles To Make Correct Tensions And Maintain Verticality Of Poles, Including Re-Jointing The Conductors In Position With New Binding Wire Complete All As Specified & Directed.. 58 Repairing Of Existing Unserviceable Pcc Coping Of Lt / Ht Pole By Breaking Completely And Material And Labour For Pcc 1:2:4 Type B1, ( Using 20Mm Graded Crushed Stone Aggregate ) Of Size 600X600x300mm Including Form Work And Applying Two Coats Of White Wash Complete All As Specified & Directed.. 59 Dismantling Andtaking Down Old U / S Earthing Andmaterial And Labour For Earthing Complete With Galvanized Steel Plate Earth Electrode 60Cmx60cmx6mm Thick Surrounded By Char Coal And Salt Buried Directly In Ground Vertically In Pit Of Depth Not Less Then 2.25 Mtr Below Ground Level With Top Edge Of The Earth Plate At Depth Of Not Less Than 1.5 Mtr Below Ground Level Surrounded From All Sides By Char Coal Dust And Common Salt In Alternate Layers Of 15 Cm Depth And Earth Plate Electrode Connected To Galvanised Earth Lead Wire Of 4.0 Mm Dia By Means Of Gi Nuts Bolts, Check Nuts And Washers And Connected To Earthing Test Point Drawn Through 15 Mm Bore Gi Pipe Medium Grade For Protection Of Gi Earth Lead Wire Including 20Mm Bore Gi Pipe Medium Grade For Watering Gi Funnel Pcc Earth Pit ( 1:3:6 ) Type C-2 With Ci Frame And Rcc Cover All As Shown In Electrical Plate No 3 On Ssr Part - I Including Testing Complete All As Specified And As Directed.Note : ( I ) The Quoted Rate Shall Include The Cost Of Earth Work, Gi Pipe For Watering, Gi Protection Pipe, Funnel, Wire Mesh, Rcc Cover, Etc. Complete. Rcc Cover Shall Be 50Mm Thick In 1:2:4 Type B-1 Using 8Mm Bars @10Cm C / C Both Way. ( Ii ) The Quoted Rate Shall Include The Cost Of The Earth Pit Covers To Be Conspicuously Marked Of Plate With Standgrouted In Pcc. ( Iii ) On Testing After Completion If The Desired Earth Resistance Ismore Than 2? The Earthing Will Be Redone At No Extra Cost 60 Supply And Fixing In Replacement Mccb Tpn 315 / 320 Amps, 415 Volts, 36 Ka, 4 Pole , Ics=100% Icu, Overload Adjustable Short Circuit Adjustable Type Incl Spreader Link And Complete Connection Complete All As Specified & Directed.. 61 Supply And Fixing In Replacement Mccb Tpn 200 Amps, 415 Volts, 25 Ka, 4 Pole , Ics=100% Icu, Overload Adjustable Short Circuit Adjustable Type Incl Spreader Link And Complete Connection All As Specified And Directed. 62 Supply And Fixing In Replacement Mccb Tpn 160 Amps, 415 Volts, 25 Ka, 4 Pole , Ics=100% Icu, Incl Spreader Link And Complete Connection All Asspecified And Directed. 63 Supply And Fixing In Replacement Mccb Tpn 630 Amps, 415 Volts, 36 Ka, 4 Pole , Ics=100% Icu, Incl Spreader Link And Complete Connection All As Specified And Directed. 64 Material And Labour For Detecting Of Fault In Cable Ht / Lt With Fault Locator Equipment Supplying Of Ht / Lt Electric Supply ( 11 Kv / 430 Volts ) To Make The Ht / Lt Cableserviceablewith Straight Throughjoint Of Size 70-300 Sqmm.Notes: ( A ) The Ht Fault Which Is Detected Through Cable Fault Locator Will Only Be Paid Under This Item. ( B ) Transportation Charges Of Cable Fault Locator And Dg Set Deemed To Be Included In The Quoted Rate. ( C ) Earth Fault Locator Will Be Provided By The Contractor For Even Single Ht Fault And No Delay On This Account Will Be Acceptable Otherwise Penalty Will Levied Rs 500.00 Per Hour. ( D ) Straight Through Joint , 95 To 300, Sqm, Labour Charges, Excavation And Making Joint Deemed To Be Including In Quoted Rate. 65 Supply And Fixing In Replacement Lt Line Separators 1100 V Grade Pvc Spacer To Separate Lt Conductor From Each Other 5 Line As Per Is Complete All As Specified & Directed. 66 Supply And Fixing In Replacementlt Line Separators 1100 V Grade Pvc Spacer To Separate Lt Conductor From Each Other 4 Line As Per Is Complete All As Specified & Directed. 67 Supply And Fix In Replacement Of Air Circuit Breaker, Fixed Type, Spring Operated, Manually Tpn, 4 Pole, 800 Amp, 415 Volts With Thermal Magnetic Release, ( O / L, S / C, E / F Protection & Confirming To Iec-60947-2& 3 Rated Breaking Capacity And Making Capacity 50 Ka Short Time Current Complete All As Specified & Directed. 68 Supply And Fix In Replacement Of Danger Notice Plate Of 1.6Mm Thick Mild Steel Sheet, Vitreous Enamelled Red, With Letters, Figures And Conventional Skull And Bones In Signal White Colour And Fixed With M.S. Clamps, Bolts And Nuts Of Approved Size, For Lt, 20X15cm Size Complete All As Specified And Directed 69 Material & Labour Chemical Spray ( Dc 2.26 Contact Cleaner ) In Container Of 415 Ml / 300G For Precision Blended Multipurpose Product For Prevents Corrosion Penetrates, Lubricants, Displaces And Seals Out Moisture Release Rusted Mechanisum Cleanese Etc Complete All As Specified & Directed.. 70 Material And Labour Inreplacementofaluminium Terminals ( Thimbles ) After Cutting The Worn Out / Faulty Cable End From Lt Pillar / Panel Box Including Necessary Earth Work For Taking Out The Cable From Loop Line, Returning, Filling In And Making Cable Lead By Providing Aluminium Lugsincluding Crimping With Crimping Tools In The Existing Lt Cable 25 Sqmm 4 Core Upto 50 Sqmm Including Necessary Connectioncomplete All As Specified & Directed. 71 All As Per Item Ser No 69 Here In Before But Size Of Lt Cable 70 Sqmm 3.5 Core Upto 120 Sqmm 3.5 Core Complete All As Specified & Directed. 72 All As Per Item Ser No 69 Here In Before But Size Of Lt Cable 150 Sqmm 3.5 Core Upto 300 Sqmm 3.5 Core Complete All As Specified & Directed. 73 Material And Labour For Shifting Heavy Items / Excavation / Cleaning Areas / Cleaning Site By Providing Crane / Hydra / Excavators / Tractors / Trolley Etc As Required At Site Complete All As Specified And Directed. 74 Material & Labour For Drilling Hole Of Any Size Manually As Per Site Requirement, Drilling For Laying Pipes Under The Road For Crossing Electrical Cable Complete All As Specified & Directed. 75 Material & Labourfor Spraying Herbicide ( Round Up ) On Area To Remove Unwanted Vegitation / Grass At Various Locations Complete All As Specified & Directed. 76 Supply And Fixing In Replacement Of On Load Change Over Switch With Sheet Steel Enclosure 415 V, 4 Pole, 630 Amps Capacity Fixed On Walls / Ms Frame / Pole / Lt Panel For Electric Supply Distribution Between Main And Dg Set Incl Necessary Connection Of Cable From Lt Panels To Change Over Switches Complete All As Specified & Directed.. 77 Taking Down Old Unserviceable Indicator Lamp Any Type Any Colour And Supply And Fixing New Indicator Red / Yellow / Green Including Making Electrical Connection With Suitable Size Of Copper Lugs Duly Crimped Complete All As Specified & Directed. 78 Re-Streching Of Loose Over Head Acsr Conductor Of Any Type / Gi Wire And Repair Of The Broken Conductors Andaddingnew Length ( If Required ) In Placeof Old And Burnt Conductor Of Any Size On Existing Poles With Proper Sagging Including Winding With Winding Wire All As Specified.Old Conductor Shall Be Reused Where Required For Repairing Broken Length Of Conductor Complete All As Specified & Directed.Note:- Each Run Of Conductor Will Be Measured And Paid Seperately. 79 Supply And Fixing In Replacement Of Sensor Of Nature Switch Operation Should Be Based On Natural Light Lux Level, Required Illuminance Level For Switching On Is <30 Lux And For Switching Off >10 Lux , The Sensor Should Also Have Part Night Operation Facility Of Min 4 Hrs To Max 12 Hrscomplete All As Specified And Directed Make:- Swadeep , Model Nature Switch -02 ( Sensor ) Or Equivalent As Approved By Ge. 80 Supply And Fixing In Replacement Of Contactor Three Pole 18 Amp In Street Light Timer Box Coil Operating Voltage 230 Volt Complete All As Specified And Directed Make- Bch / L&T Or Equivalent As Approved By Ge 81 Supply And Fixing In Replacement Of Contactor Two Pole 25 / 40 Amp In Street Light Timer Box Coil Operating Voltage 230 Volt Complete All As Specified And Directed Make- L&T / Bch Or Equivalent As Approved By Ge 82 Supply And Fixing In Replacement Ofcontactor Coil ( 230V ) For Mu Series 25 / 40 Amps 2 Pole Contactorscomplete All As Specified And Directed Make- L&T ( Cat No Cs90793 ) Or Equivalent As Approved By Ge 83 Supply And Fixing In Replacement Ofcontactor Coil ( 240V ) For Freedom Series 18 Amps 3 Pole Contactorscomplete All As Specified And Directed Make- Bch, Cat No Ce15d1n-K Or Equivalent As Approved By Ge 84 Supply And Fixing In Replacement Ofvms ( Voltage Monitoring Series ) In Street Light Timer Box, Including All Salient Features Such As Selectabe Under / Over Voltage Trip Levels, Protection Against Phase Loss & Natural Loss, Protecotion Against Phase Reversal And Phase To Phase Unbalance ( 10% ) , Voltage Sensing Principle And Led Indications For Power And Fault Conditions Complate All As Specified And Directed Make- L&T, Cat No Sm500 Or Equivalent Of Gic 85 Material And Labourforaluminium Conductor Steel Reinforced ( Acsr ) Conductor Of Size Isi Marked For Lt Over Head Lines On Poles Including Stretching, Tightining Of Poles Insulator With Winding Wire Of Suitable Size With Insulator / Strechingof Acsr Conductor Including Dismantling And Taking Down Old Unserviceable Acsr Conductor Incl Cutting, Welding Complete All As Specified & Directed. 86 Material And Labour For Vibratory Compactive, Precast Cement Concrete Rubber Moulded, Coloured ( Except Grey Colour ) , Interlocking Designer Paver Blocksin Milano Shape, Comfirming To Is-15658-2006 Of 60 Mm Thickness, M-35 Grade, As In Path, Hardingstanding, Etc Laid Over And Including 25 Mm Compacted Sand Cushioning, Including 75 Mm Thick Pcc 1:4:8 Type D-2 Using 40Mm Graded Crushed Stone Aggregate Including Surface Excavationover Area N. Exc. 30 Cm Deep And Averaging 15 Cm Deep And Getting Out In Soft / Loose Soil And Removing Excavated Soil Exc. 50 Mtr But N. Exc. 250 Mtr Includig Demolition Of Existing Paver Blocks, Complete All As Specified & Directed. 87 Earthing Complete With Galvanisedearth Plate Electrode 600Mm X 600Mmx 6.00Mm Thick Surrounded By Charcoal And Salt, Buried Directly In Ground Vertically In A Pit Of Depth Not Less Than 2.25M Belowground Level With Top Edge Of The Earthplate Not Less Than 1.5M Belownormal Groundlevel, Connected To 25X4 Mm Gi Strip Earth Lead By Means Of Bolts, Nuts, Checks Nut And Washers Made Out Of Galvanized Iron Or Steel, Earth Wire Protected By Galvanized Steel Pipe 40Mm Bore Medium Grade And Connected To Main Switch Or Main Control Board All As Shown In Electrical Plate No.3 Of Ssr Part-I & Including Necessary Excavation And Earth Work. The Rate Also Include Charcoal & Salt In Alternate Layers, 20Mm Bore Gi Pipe Medium Grade For Watering And 40Mm Bore Giprotection Pipe ( Light Grade ) , Funnel, Wire Mesh, Cast Iron Cover Andframe Etc, Complete, All As Specified Or Indicated And As Directed Including Testing On Completion Including Dismantalling Of Old U / S Earthing Complete All As Specified And Directed.Note : ( I ) The Quoted Rate Shall Include The Cost Of Earth Work, Gi Pipe For Watering, Gi Protection Pipe, Funnel, Wire Mesh, Rcc Cover, Etc. Complete. Rcc Cover Shall Be 50Mm Thick In 1:2:4 Type B-1 Using 8Mm Bars @10Cm C / C Both Way. ( Ii ) The Quoted Rate Shall Include The Cost Of The Earth Pit Covers To Be Conspicuously Marked Of Plate With Standgrouted In Pcc. ( Iii ) On Testing After Completion If The Desired Earth Resistanceis More Than 2?The Earthing Will Be Redone At No Extra Cost 88 Supply And Fixing In Replacement Indoor / Outdoor End Termination Joint Heat Shrinkable 1100 Volts For Xlpe Cable Of Size 3.5 / 4.0 X 10-50 Sqmm Including Complete All As Specified & Directed. 89 Supply And Fixingin Replacement Indoor / Outdoor End Termination Joint Heat Shrinkable 1100 Volts For Xlpe Cable Of Size 3.5 X 70-120 Sqmm Including Complete All As Specified & Directed. 90 Dismantling And Taking Down Old Unsv Lt Panel And Supply, Installing, Testing & Commissioning Outdoor Type Cubical Panel Board Of Size 1.2Mx1.0Mx.5M, Outer Shell Made Out Of3.15 Mm Thick Crca Sheet And Inner Shell Made Out Of 2 Mm Thick Crca Sheet And Ms Angle Section 50X50x6 Mm Mounted On Pcc 1:2:4 Type B-1 Platform 60 Cm Aboveand 45 Cm Below The Ground Level, Frame Factory Fabricated With Front And Back Openable Double Door System And Cable Alley ( Each Door Hinged With Body At 3 Places With Body And Hinges Should Be Welded With Body And Door ) Lockable / Open Ablewith Arrangement Of Pad Locking On Both Doors Incl 2 No. Of Pad Locks Of Three Keys Shall Be Used To Make The Outer Shell Completely Vermin Proof Suitable For 3 Phase 4 Wire 415 Volt, 50 Hz, Incl Copper Bus Bar Of 400 A , Tested At Factory Approved From Cpri Factory Fabricatedhaving Modern Fabrication And Testing Process Followed By Powder Coat Painting Having Thickness Not Less Than 100 Microns Provided With Suitable Gasket To Make It Dust / Vermin Proof And General Construction Confirming To Is:61439 / 2011Part-1 Andpart -2 Type Test Certificate With Not Less Thanip-56And Breaking Capacity 65 Ka Comprising Of The Following :- ( A ) Mccb400 Amps, 50 Ka 4 Pole 415 Volts Ac, Adjustable Type, ( Incoming ) -01 No. ( B ) Mccb125 Amp, 415 Volt, 4 Pole, Breaking Capacity 25 Ka , Adjustable Type ( Outgoing ) -04 Nos. ( C ) Ryb Indication Led Type, 22.5 Mm Dia, Protected With Mcb Sp 2 Amp Showing 3 Phase Supply -03 Nos ( F ) Digital Ammeter Of Range 0-500 A, Auxiliary Voltage 230 Volts With Selector Switch -01 Nos ( G ) Digital Volt Meter Of Range 0-500 Volts, Auxiliary Voltage 230 Volts With Selector Switch -1 No ( H ) Misc Items Like Screws, Cable Tie, Copper Cable 1.5 / 2.5 Sqmm, Cabe Lugs, Sleeves, Glands Etc Complete Are Included In Quoted Rates. 91 Dismantling And Taking Down Old Unsv Lt Panel And Supply, Installing, Testing & Commissioning Outdoor Type Cubical Panel Board Of Size 1.2Mx1.0Mx.5M, Outer Shell Made Out Of3.15 Mm Thick Crca Sheet And Inner Shell Made Out Of 2 Mm Thick Crca Sheet And Ms Angle Section 50X50x6 Mm Mounted On Pcc 1:2:4 Type B-1 Platform Block Type 60 Cm Above Ground Level And 30 Cm Grouting In Ground, Frame Factory Fabricated With Front And Back Openable Double Door System And Cable Alley ( Each Door Hinged With Body At 3 Places With Body And Hinges Should Be Welded With Body And Door ) Lockable / Open Ablewith Arrangement Of Pad Locking On Both Doors Incl 2 No. Of Pad Locks Of Three Keys Shall Be Used To Make The Outer Shell Completely Vermin Proof Suitable For 3 Phase 4 Wire 415 Volt, 50 Hz, Incl Copper Bus Bar Of 400 A , Tested At Factory Approved From Cpri Factory Fabricatedhaving Modern Fabrication And Testing Process Followed By Powder Coat Painting Having Thickness Not Less Than 100 Microns Provided With Suitable Gasket To Make It Dust / Vermin Proof And General Construction Confirming To Is:61439 / 2011Part-1 Andpart -2 Type Test Certificate With Not Less Thanip-56And Breaking Capacity 65 Ka Comprising Of The Following :- ( A ) Mccb315 Amps, 36 Ka 4 Pole 415 Volts Ac, Adjustable Type, ( Incoming ) -01 No. ( B ) Mccb100 Amp, 415 Volt, 4 Pole, Breaking Capacity 16 Ka , ( Outgoing ) -04 Nos. ( C ) Ryb Indication Led Type, 22.5 Mm Dia, Protected With Mcb Sp 2 Amp Showing 3 Phase Supply -03 Nos ( D ) Digital Ammeter Of Range 0-500 A, Auxiliary Voltage 230 Volts With Selector Switch -01 Nos ( E ) Digital Volt Meter Of Range 0-500 Volts, Auxiliary Voltage 230 Volts With Selector Switch -1 No ( F ) Misc Items Like Screws, Cable Tie, Copper Cable 1.5 / 2.5 Sqmm, Cabe Lugs, Sleeves, Glands Etc Complete Are Included In Quoted Rates. 92 Receiving / Recording Complaints Under Allenby Line Power House Of Perimeter / Security / Street Lights To Comprehensive Maintenance By Attendng Daily Complaints Including Sunday And Other Holidays For 08 Hrs And Making The Same Serviceable In All Respects Alongwith Replacement Of Any Major Part But Including Small Length Of Cable ( Not More Than 20 Mtr ) , Adhesive Tape And Other Connected Minor Accessories Shall Also Include To Visual Inspection. Quoted Rate Also Include Excavation Offaulty Cable Below The Pole And Making Seviceable With Accessories Of All Nature Like Faulty Light, Faulty Insulator, Broken Conductor & Cable Fault, Burnt Out Mcbs, Isolators, Switch Fuses, Service Cables Etc Sector `C-2`Areacomplete All As Directed To The Entire Satisfaction Of Engineer-In-Charge.Note ‘A’ :- ( I ) Any Complaint Left Unattended By The Electrician Shall Be Communicated To The Je In-Charge / Age E / M With Reason. No Charge Shall Be Paid For The Complaint Per Day Till The Complaint Is Resolved. ( Ii ) New Material / Stores Provided For Completing The Job Shall Be Measured And Paid For Separately Under Relevant Items Of Boq. ( Iii ) Contractor Shall Provide All Type Of T&P Of Lt Network, Bamboo Ladder ( 23 Feet ) With Safety Gloves To Electrician For Attending The Street Light Complaints ( Iv ) Contractor Shall Provide The Complaint Register 200 Pages – 10 No, Complaint Book With 100 Slips- 20 No. Booklets Serially Numbered In Triplicate. ( V ) Contractor Shall Provide 01 No. Experienced Electrician Having Minimum 5 Years Experience ( 01X 08 Hrs Per Day ) And 01 No. Helper Having Minimum 2 Years Experience ( 01 X 08 Hrs Per Day ) Including Sundays And Holidays To Attend The Complaints. ( Vi ) The Contractor Shall Provide Insurance Cover Of Minimum Rs 5 Lakh Per Head Under Ie Rules 2003 And Minimum Wages Act. ( Vii ) The Electrician And Helper Will Be Interview By Je E / M / Engr-In-Charge For Verification Of Experience, Character And Sound Mind And Body. ( Viii ) Cost Of Materials For Replacement Of Lights, Mcbs, Pole Junction Box, Brackets, Clamps, Insulator And Jumper Shall Be Measured And Paid Separately Under Relevant Items As Material & Labour. 93 Supply, Fixing And Testing Of Auto Day / Night On And Off Photocell.Ldr Sensor Switch 06 Amps For Lighting On And Off Photocell, Ldr Sensor Switch 6Amps For Lighting On And Off Water Proof 220Volt 50Hz, Ac Supply, Model No Quick Sense Qs-301 Complete With All Accessories Internally Pre-Wired Including Connection With 1.5Sqmm Copper Conductor From Main Supply To Sensor, Sensor To Fittings Including Taking Down Existing Complete All As Specified & Directed.. 94 Supply, Fixing And Testing Of Auto Day / Night On And Off Photocell.Ldr Sensor Switch 10 Amps For Lighting On And Off Photocell, Ldr Sensor Switch 6Amps For Lighting On And Off Water Proof 220Volt 50Hz, Ac Supply, Model No Quick Sense Qs-301 Complete With All Accessories Internally Pre-Wired Including Connection With 1.5Sqmm Copper Conductor From Main Supply To Sensor, Sensor To Fittings Including Taking Down Existing Complete All As Specified & Directed.. 95 Note:-Amount Of Credit Ofrs. 105485.00 For Retrieved Materials Is Mentioned In Schedule Of Credit Of Tender Documents In Pdff Form Which Will Be Deducted Offline While Acceptance Of Tender.
BRR : 7080606
Tender For Increasing Capacity Of 33/11Kv S/S Quila Bareilly, INCREASING CAPACITY OF 33/11KV S/S QUILA FROM 3X10 MVA TO 3X10+5 MVA UNDER EUDC BAREILLY IN ADDITIONAL BUSINESS PLAN 2024-25 Sl. No. Item Description 1 Loading, unloading and safe carriage of the following materials from any electricity Store Center of Electricity store division MVVNL Bareilly 2 M.S. Channel 125x65mm 3 M.S.Angle 75x75x8mm 4 MS Angles 50x50x6mm 5 33 KV Post insulator 6 33 KV Lightening Arrestor 7 33 KV Line Isolator 8 33 KV 400 A Bus Isolator 9 33 KV VCB 800A 750 MVA 10 33 kv O/D CT CTR 200/100/1-1-1 A 11 33 kv O/D CT CTR 400/200/1-1-1 A 12 11 KV VCB I/C CTR 600/300/5A 13 11 KV VCB O/GCTR 200/100/5A 14 11 KV 3x300 mm2 XLPE Cable 15 11 KV 3x185 mm2 XLPE Cable 16 33 KV 3x300 mm2 XLPE Cable 17 11 KV Cable jointing Kit 18 33 KV Cable jointing Kit 3x300 mm2 S/th and O/D 19 PCC Pole 8.5m long. 20 Earthing Complete 21 11KV Disc Insulator B&S7000 Kg 22 33 KV Disc fitting for Dog conductor 23 11 KV disc insulator 24 11 KV disc fitting 25 Cost of ACSR Dog conductor 26 Earthing of indoor & outdoor equipments of Sub-Station after proper welding of joints and painting of earth strip above soil with proper clamp etc. as per RESPO approved drawing & resistance of earthing should be not more than 2Ω as per details given below. 27 Making of triangular bridge by using MS electrode, GI strip 50x6mm and GI Pipe 40 mm dia with providing of well type pipe earthing upto 15 Mtr. depth below ground level including welding etc. by boaring process at T/F neutral, LA and newly erected structure including cost of GI pipe of size 40 mm dia 15 mtr. long of ISI mark (all the required material will be supllied by the contractor). 28 Supply of GI strip of size 50x6mm for earthing of all newly erected structures and equipments in switchyard including cutting, fixing & proper welding with equipments. All LA will be seprately earth also as per RESPO norms. (All the required materials will be provided by firm.) 29 fabrication, erection and grouting of the following structures as per RESSPO/ Approved Drawing and its, plinth 30 cm above ground level as directed by the Engineer Incharge, Grouting of structure will be done in 1:4:8 ratio of cement, sand & coarse aggregate with material including all accessories. 30 Bus Bar gantry structure 31 Post insulator Structure 32 Bus Isolator Structure 33 Line Isolator Structure 34 33 KV VCB Structure 35 33 KV CT Structure 36 Fuse Set Structure 37 Lightening Arrestor Structure 38 Mounting and installation, including mechnical & electrical fixing and adjusting of the following equipments on their respective structures including proper adjustment: 39 33 KV Fuse Set 40 33 KV Bus Isolator 41 33 KV Line Isolator 42 Lightening Arrestor 43 33 KV VCB 44 33 KV CT (3 Nos) 45 33 KV Post insulator 46 Providing of DC supply system with one no. float cum boost charger & 01 battery set for 24V. DC supply system with 200A.H. battery capacity with cabnet 47 Complete laying and termination of copper control cable in PVC Pipe 4 dia from 10 MVA power T/F and 33 KV VCB in the outdoor switch yard in the Transformer relay control panel inside the control room including cost of all materials and labour required for proper completion of works as per RESSPO drawings. 48 Stringing of 33 KV Bus bar with ACSR Dog conductor including making vertical/horizontal jumper connections through PG clamps and connecting all the equipments with each others through connecting clamps, work includes all the jumpering from bus bar. (All type of fitting, PG clamp etc. provided by Firm). 49 Making of M.S. Angle Ladder type frame of Angle (65x65x6mm) & M.S. Strip (50x6mm) near power transformer for power cable with concreting in 1:4:8 ratio of cement, sand & coarse aggregate and proper clamping (50x6mm) of the same with transformer cable (grouting materialwill be provided by The firm). 50 Making of M.S. Angleframe of (65x65x6mm) in the shape of L to connect T/F Neutral bycopper flexible strip with proper clamping including cost of copper strip. Earthing of Power T/F Neutral shall be done separately including welding with M.S. bar Electrode bridge 1 No. after making in triangular shape and proper connection with well type earthing etc. Grouting of structure will be done in 1:4:8 ratio of cement, sand & coarse aggregate(grouting materialwill be provided by The firm). 51 Laying of 11KV and 33KV cable of different size from power T/F to control room I/C and control room to D/P outside Sub-Station over a pad of river sand . Cable shall be laid 500mm below the ground in the yard by covering three sides with Ist Class brick and Ganga sand (All type laying material will be provided by the Firm except 11 KV cables ). 52 11 KV Cable hoisting with MS Pipe in cost of material. 53 Erection and grouting of double pole structure of PCC Poles/S.T. Pole including stays for 11KV out door feeders, complete in all respect as per RESSPO drawing along with grouting material about 3 meter 4 dia G.I. pipe along with required elbow shall be provided at D/P for power cable including provision of 02 Nos. feeders name plate on D/P. 54 Erection of 1 no. 11 KV incoming panels, 02 no. 11KV outgoing panels (with testing & setting of relays) in substation control room including grouting of Anchor bolts of panel and making of pocket for power cable to insert in panel from trench and complete filling of control rooms tranches by river sand. 55 Termination of 11 KV Different size XLPE cable by filling 11 KV heat shrinkable type cable boxes including proper connection with LV side of T/F switch gear panels and double poles by providing suitable connectors. 56 Fixing of 33 KV 3x300 mm cable box I/D and S/Th. 57 Shifting and dragging of 33/11 KV 5 MVA transformer from road side to its plinth alongwith its erection including fixing of all assessories and top-up of T/F oil. 58 Work related maintenance of old and used 5 MVA Power Transformer. 59 Attending of leakage of power transformer (Replacement of damage gasket kit etc)(all required material will be provided by firm.) 60 Centrifusing of transformer oil. 61 Replacement of damage brether and silica jel.(all required material will be provided by firm.) 62 Replacement of damage WTI and OTI.(all required material will be provided by firm.) 63 Painting of old transformer.(all required material will be provided by firm.) 64 Replacement of damage buchholz relay(all required material will be provided by firm.) 65 Replacement of damaged 33kv, 11kv bushings (all required material will be provided by firm.) 66 Carriage and top up of transformer oil from any store/workshop of Bareilly Zone 1, Bareilly Zone 2 67 Repairing of existing 33 KV double transformer control panels in substation including repalcement of all required accessories as relay, indication lamp, voltmeters, ammeters, trip&close remote switch etc. All type of material should be provided by the firm. 68 Painting of the all structures (old & new) with one coat of red oxide primer and two coats of synthetic enamel alumm. Paint/green paint of ISI Mark alongwith earthing strip above ground level. 69 Making of stairs on existing power transformer plinth ( Stair steps size 2mtr. long x 300mm width x 200 mm depth ) by using first class brick, sand and cement. All material will be provided by firm. 70 Dismantling of control room wall from back side of 11KV VCB Panels (2.00 Mtr. long and 2.5 Mtr. height) and making and fixing of G.I. gate (1.00 Mtr. long and 2.0 Mtr. height). All material will be provided by firm. 71 Shifting of all 11KV incomer panels, all 11KV outgoing panels and all 11KV bus coupler panels in the control room as per requirement of work. 72 Providing of rubber matting sheet 8/10mm
BRR : 2094402
Tender For Repairs, Maintenance And Replacement Of Lt Cables Street Lights Fittings Perimeter Lights Incl High Mast Tower And Connected Items In Tech Area At Af Stn Bhuj - Excavation in trenches not exc. 1.5m wide and not exc. 1.5m in depth for foundation etc or for shafts, wells, cesspits, manholes pier holes etc not exc. 10sqm on plan and not exc 1.5m in depth and getting out in hard/dense soil soil complete all as specified and directed by Engineer-in-Charge. 2 Returning filling in soil and including spreading leveling watering and well ramming in layers n.exc. 25 cm thick complete all as specified and directed by Engineer-in-Charge. 3 Removing excavated soil to a distance n.exc. 50 mtr and depositing where directed at a level n.exc. 1.5m above the starting points complete all as specified and directed by Engineer-in-Charge. 4 Material & labour for sand cushioning for UG cables using dry river sand; gently punning down complete all as specified and directed by Engineer-in-Charge.( Note : For measurement purpose punned thickness shall be considered) 5 Material & labour for unreinforced precast concrete cable covers CLASS LV type II, flat size 300 x 180 x 40 mm laid transverse to cable complete all as specified and directed by Engineer-in-Charge. 6 Taking out unserviceable LT cables from excavated trenches, ducts, wall, pole etc including removing cable covers, sand, cable joints, pipes, clamps etc, taking out old serviceable cables, cable covers, etc for reuseand removing unserviceable cables, covers etc, for the following sizes of cables :- 7 LT cables up to 10 Sqmm, any core 8 LT cables up to 16 Sqmm, any core 9 LT cables up to 25 Sqmm, any core 10 LT cables up to 35 Sqmm, any core 11 LT cables up to 50 Sqmm, any core 12 LT cables up to 70 Sqmm, any core 13 LT cables up to 95 Sqmm, any core 14 LT cables 120 Sqmm, any core 15 LT cables 150 Sqmm, any core 16 Relaying serviceable cables in trenches, ducts, on wall, pole etc after testing of retrieved cable by megger complete all as directed for following sizes of cables :- 17 LT cables up to 10 Sqmm, any core 18 LT cables up to 16 Sqmm, any core 19 LT cables up to 25 Sqmm, any core 20 LT cables up to 35 Sqmm, any core 21 LT cables up to 50 Sqmm, any core 22 LT cables up to 70 Sqmm, any core 23 LT cables up to 95 Sqmm, any core 24 LT cables 120 Sqmm, any core 25 LT cables 150 Sqmm, any core 26 Supply & Fix in replacement,connecting,testing and commissioning and jointing,LT under ground cable 1100 volts grade,XLPE insulated,armoured with galvanized round steel wire or steel strip, electric power cables heavy duty, with multi stranded aluminum conductor, laid in trenches,ducts,fixed on poles/walls with proper size saddles and clamp laid under roads /path /drain /culverts or encased in GI pipe fixed & testing and commissioning complete all as specified and as directed by the Engineer-in-Charge of following Sizes:-Note:- (i) Sand cushioning, Cable protection cover, GI pipes, excavation and earth work shall be measured and paid for separately under respective items of Schedule A . 27 LT cables up to 10 Sqmm, any core 28 LT cables up to 16 Sqmm, any core 29 LT cables up to 25 Sqmm, any core 30 LT cables up to 35 Sqmm, any core 31 LT cables up to 50 Sqmm, any core 32 LT cables up to 70 Sqmm, any core 33 LT cables up to 95 Sqmm, any core 34 LT cables 120 Sqmm, any core 35 LT cables 150 Sqmm, any core 36 straight through joint (epoxy) for LT 1100 Volts grade, aluminum conductor including jointing kits, aluminium ferrules and labour complete all as specified and directed by Engineer-in-Charge. for making joints and testing for following sizes: - . 37 Cable size 120 to 150 Sqmm, 3.5 core 38 Cable size 70 to 95 Sqmm, 3.5 core 39 Cable size upto 50 Sqmm, 3.5 core 40 Supply & fix GI tubing light grade for encasing cables for mechanical protection, laid under plinth/floors/ roads/ path /culverts or fixed on walls/on poles by means of MS FI clamps with necessary bolts, nuts and washers complete all as specified and directed by Engineer-in-Charge for following sizes : - 41 50mm bore 42 80mm bore 43 100mm bore 44 Supply & fix in replacement MCCBs,415 Volts,Fix / adjustabletype having complete all as specified and directed by Engineer-in-Charge for following capacities. 45 MCCB 3 Pole, 415 V, fixed type, 25 to 100 Amps with breaking capacity 16 KA 46 MCCB 3 Pole, 415 V, fixed type, 125 Amps with breaking capacity 16 KA 47 MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA 48 MCCB 4 Pole, 415 V, Adjustable type, 200 Amps with breaking capacity 36 KA 49 MCCB 4 Pole, 415 V, Adjustable type, 250 Amps with breaking capacity 36 KA 50 MCCB 4 Pole, 415 V, Adjustable type, 400 Amps with breaking capacity 36 KA 51 Material & labour for earthing complete with GI earth plate electrode 60cmx60cm x 6 mm thick buried directly in ground vertically to depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr below normal groundlevel connected to and including GI strip of 32x6mm as earth lead up to 7.5 mtr long fixed by means of bolts, nuts, check nuts and washers etc. of galvanised iron or steelincluding provn of GI protection pipe light grade of 32/40mm bore and connected to earth strip earthing test point all as shown in electrical plate No.5 of SSR Part-I 2009 and as specified or indicatedand testing on completion including necessary excavation & earthwork in any type of soil, PCC (1:3:6) type C1 chamber, precast slab 50mm thick in cement concrete (1:2:4)type B1 (reinforced with welded steel wire fabric (XPM) of weight not less than 4kg/sqm) with frame, funnel with watering pipe of 15mm bore Sch.40, wire mesh and lugs, test point etc. complete all as specified and directed by Engineer-in-Charge.Note: GI strip exceeding 7.5m long shall be measured & paid seperately. . 52 Material & labour for complete cleaning of the internal & external parts of LT panel; checking & testing of all the components of the panel for cable insulation, lugs, connections and the like; replacement of & including provision of minor parts like lugs, insulation tape, nuts bolts, connectors and the like as directed by Engineer-in-Charge; replacement and / or welding of existing damaged hinges of the panel; preparation of old painted surfaces (internal & external) of the panel, complete removal of existing paint using emry paper grade 220, by sanding and scrubbing, application of corrosion resistant primer by sprayers, applying hammer finish metal paint using sprayers in two coats and till shining surfaces are obtained; application of two coats of epoxy black paint on panel frames; complete all as specified and directed by Engineer-in-Charge. (Approximate average size of panel=1.50x0.75x0.45m) (Note - Rates included for provision of sufficient technicians for getting electric shut down and to attend the shutdown on site till completion. Replacement of major items like MCCBs etc. shall be measured & Paid for separately). 53 Material & labour for Zebra painting white & sky blue strips 30 cm height in alternate colour strip upto 1.5 meter from top edge of coping of electric poles with synthetic enameled paint two coats and numberingto poles with 80mm size letter with black synthetic enameled paint complete all as specified and directed by Engineer-in-Charge. 54 Supply & Fix in replacement FRP juction box of size outside dimensions 380x 225x 140 mm of make sintex, Cat No GSJB-3923 or equivalent as approved by the GE including connector suitable for 63 Amps with and includingMCB SP C series6 Amps - 01 No and fixing on pole with and including MS clamps made out of 25 x 3mm MS flat iron, nut, bolts etc complete all as specified and directed by Engineer-in-Charge. 55 Supply & fix in replacement of 150W MH flood light with LED flood light-High Lumen output fitting of 100 Watt with exclusive innivative designed, long life versatile pressure die cast aluminium IP65 flood light luminaire with high power LED as light source complete all as specified and directed by Engineer-in-Charge. 56 Supply & fix in replacement of pin type, (LT) porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut,100mm height, 65mm dia for 1100 volts grade complete all as specified and directed by Engineer-in-Charge. 57 Supply & fix in replacement shackle type procelain, vitreouswhite, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nutsof 75mm height, 90mm max dia for 1100 volts gradecomplete all as specified and directed by Engineer-in-Charge. 58 Dismantling the damaged ACSR/ AAC conductors all sizes from the OH lines complete all as specified and as directed byEngineer-in-Charge. 59 Supply, stringing, streching and binding with insulator including binding wire of 16 SWG aluminium wire ACSR conductor of any size in over head line LTpoles to the insulator complete with necessary Jumpercomplete all as specified and as directed byEngineer-in-Charge. 60 Material & labour for wiring Circuit along withearth wire from Sintex box to Streetlight fitting with 3 run of 2.5 sqmm sizesFR PVC insulated copper conductor single core cable in suraces/recessed as required including Steel conduit of size 20 mm dia complete all as specified and directed by Engineer-in-Charge. 61 Supply & fix in replacement of 200 Amps , 415 volts off-Load changover open type sutable for panel mouted front operatedtesting complete all as specified and directed by Engineer-in-Charge. 62 Supply & fix spacer made out of hard/rigid PVCas approved by Engr-in-Charge on the LT OH line suitable for 4 wire system LT OHACSR conductor complete all as specified and directed by Engineer-in-Charge. 63 Supply & fix loop type insulator viterous porcelain white,brown orgreen of small size with overall dimensions 65 x 90 mm,clarance of hole 16mm complete all as specified and directed by Engineer-in-Charge. 64 Supply and fix Stay assembly complete with accessories as shown in electrical plate No.1 comprising of 7/4 mm galvanised MS standard wire of required length fixed to pole with and including flat iron clamps fabricated out of 50 mm x 6mm flat iron and nuts,bolts and washers of suitable sizes including painting with two coat of aluminium paint over a coat red oxide as primer,GI stay rod 16mm dia 1850 mm long MS stay plate GI 300mm x 140mm clearance dia of hole 25-5 mm suitable for HT/LT poles,complete all as specified and directed by Engineer-in-Charge.(Note:-Excavation,earth work and concrete work,insulator shall be measured and paid seperately under relevant item of this schedule. 65 Supply and fix cross arms, bracings supports, clamps, and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one coat of red oxide primer, two coats of alumuinium paint complete all as specified and directed by Engineer-in-Charge 66 Material & labour for PCC 1:2:4 type B1 with 20 mm graded well burnt brick aggregate forcoping, topping of plinth of panels, repairing / making connected path to panels/ transformer etc complete all as specified and directed by Engineer-in-Charge 67 Material & labour for PCC 1:3:6 type C2 with 40 mm graded well burnt brick aggregate for foundation ofpoles/panels transformer, and connected path complete all as specified and directed by Engineer-in-Charge 68 Material & labour for in replacement of prestressed concrete poles, 9.0 meters long, 102mm x 172mm at top and 102mm x 279mm at bottom, class 10 complete all as specified and directed by Engineer-in-Charge 69 Supply & fix 60 watt LED street light luminaries comprising of cast aluminium housing, toughned glass, IP 65/66 and wired with all accessories enclosed with glass cover in frame including suitable size of street light bracketcomplete all as specified and directed by Engineer-in-Charge. 70 Material & labour for earthing complete with copper earth plate electrode of size 60cmx60cm x 3.15 mm thick buried directly in ground vertically to depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr below normal groundlevel connected to and including copper stripof 20 x 3 mm as earth lead up to 7.5 mtr long fixed by means of bolts, nuts, check nuts and washers etc. of galvanised iron or steelincluding provn of HDPE protectionpipe light grade of 32/40mm bore and connected to earth strip earthing test point all as shown in electrical plate No.5 of SSR Part-I 2009 and as specified or indicatedand testing on completion including necessary excavation & earthwork in any type of soil, PCC (1:3:6) type C1 chamber, precast slab 50mm thick in cement concrete (1:2:4)type B1 (reinforced with welded steel wire fabric (XPM) of weight not less than 4kg/sqm) with frame, funnel with watering pipe of 15mm bore Sch.40, wire mesh and lugs, test point etc. complete all as specified and directed by Engineer-in-Charge. Note: Copper strip exceeding 7.5m long shall be measured & paid seperately. 71 Supply & fix in replacement of copper strip 20 x3 mm with saddles and fixing screws etc for jointing withtransformer and lightening arresterswith the earth pit stripetccomplete all as specified and directed by Engineer-in-Charge. 72 Labour for Laying only retrievedfifty percentserviceable cable covers obtained while taking out U/G cable from srl item No.32 abovecomplete all as specified and directed by Engineer-in-Charge. 73 Supply & fix finding out LT fault in feederofaffected area with deploying trained electrician and helper seggregate/ isolatethe feeder carry out maintenance worksuch as repair of jumper,insulators ,conneted items and then after charge the feeder with load in presencecomplete all as specified and directed by Engineer-in-Charge. 74 Supply & fix in Fabricating Outdoor LT Feeder distribution panel (CPRI Approved) LT electrical distribution panel board floor mounted cubicle type suitable for one incoming MCCB and two outgoing MCCB, one multifunction LED Meter dust proof weather proof vermin proof asthetically designed having at least IP-54 degree of ingress protection fabricated from 3.15 mm thick CRCA sheet with front and rear opening including bus bar chamber continuous GI strip earth bus bar 4 strip of Aluminium bus bar 250 amp capacity insulated colour sleeves precilin/ epoxy insulator rai channel cable alloy danger notice board including made out of 14 gauge CRCA Sheet over angle iron frame of size 40x40x6 mm, 30 cm grouted in groung floor and 30 cm above GL including connection with suitable copper cable FRLSH PVC single corecomplete all as specified and directed by Engineer-in-Charge.(i)MCCB 160 Amps 25 KA, 4 pole with adjustable thermal setting -01 No (Incoming)(ii)MCCB 100Amps 25 KA, 4 pole with adjustable thermal setting -01No (outgoing)(iii)MCCB63 Amps 16 KA, 4 pole with adjustable thermal setting -02 No (outgoing)(iv) LED Multifunction MeterInput voltage measurement range 17-520 VAC (P-P)Aux supply 90-300 VACFlush mounting 96 x 96 mmSite selectable 1A /5ACT/PT site programmable V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh, Run hours etc 75 Supply & fix in repalcement 120 Watt new generation, energy saving environment friendly & robust highbay LED with PDC housing suitable for ceiling (surface/suspended) mounting with system efficacy upto 150L/watt complete all as specified and directed by Engineer-in-Charge.
Disclaimer
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tender Detail
| Website | https://tender.nprocure.com/ |
| Quantity | |
| MSME Exemption | No |
| Tender Type | Open Tender |
| Startup Exemption | Click Here |
| Competitive Bidding | NCB |
TENDER INSIGHTS
858
Electric TendersLive
Tell us about your Product / Services,
We will Find Tenders for you