TDR : 56653536
Gujarat Energy Transmission Corporation Limited

Tender Brief :

Vadodara, Gujarat

Tender For Erection of Structures, Equipments, Earthing, Control Wiring, Yard Lighting, Control-Room Staff Quarter Electrification etc. for 2X15MVA, 66/11kV Khatiyawant Sub-Station under TASP scheme associated 2 nos. of opposite end feeder bay along

Published: 24 Jul 2026
Opening: Ref Document
Closing: 14 Aug 2026
Amount: 40.30 Lakhs
EMD: 40310
Tender Fee: 1180


Works Active Harmonic Filter Actuator Aerial Cable Aerodrome Beacon Air Circuit Breaker
13
Days Left
Tender Summary / Eligibility Criteria
Erection of Structures, Equipments, Earthing, Control Wiring, Yard Lighting, Control-Room Staff Quarter Electrification etc. for 2X15MVA, 66/11kV Khatiyawant Sub-Station under TASP scheme associated 2 nos. of opposite end feeder bay along with Re-arrangement of 02 nos. of 66kV PT bay at 220KV Kawant S/s; Tal: Kawant Dist: Chhota Udaipur under Construction Division Jambuva of Jambuva TR circle.
Documents Download All
2f4717a5b2c64c1a97c5b4b70d3b0961
2f4717a5b2c64c1a97c5b4b70d3b0961.html
JTC2627n98
JTC2627n98.pdf
No Boq
No Corrigendum
Probable Bidders

AI engine predicts probable bidders to help you bid strategically.

MSME Exception
Explore More →
Technical
Tender involves procurement of high capacity electrical equipment including diaphragm coupling of pump & motor with 90kW capacity at 2900 RPM. The project scope includes installation, testing, commissioning and operational handover.
Previous / Similar Result
BRR : 10218452 Work Contract For Supply Of Sundry Materials Transportation Earthing Arrangements Electrification Of Control Room Building Furnitures Required Towards Establishment Of New 33 Kv Ss At Airport Staff Quarters-- 1 SUPPLY OF MATERIALS 2 MS Channel 100mm x 50mm 3 MS Angle 65mm x 65mm 4 MS Flat 50 x 8mm 5 MS Rod 40mm dia 6 33kV, 1X630 Sq.mm, Aluminium Clamp 7 11kV, 1X630 Sq.mm, Aluminium Clamp 8 Rubber Mat 9 Plastic Name Board ( Feeder Name, LC board, Back charged etc.,) 10 33kV & 11 kV breaker name plate details stickers 11 First aid box 12 Wall clock 13 Entrance Floor Mat 14 Welcome Mat 15 Schematic layout board ( wooden / plastic / Aluminium) having the size of 1200mm x 600 mm and board covered with 3mm thick achorlic transparent sheet. 16 Earthing layout board ( wooden / plastic / Aluminium) having the size of 1200mm x 600 mm and board covered with 3mm thick achorlic transparent sheet. 17 TRANSPORTATION & LABOUR WORKS 18 Labour charges for transporting the 33KV VCB Panel having 2m to 2.5m height and 3m length and weighing of about 3.5 tonne carefully from CDC Stores to newly proposed 33/11kV indoor SS at Airport staff Quarters Chennai. including loading and unloading moving safely by use of cranes. This includes moving the package from inside the store shed to its ramp and inside to the substation control room(Transformer Panel 2 nos., + Feeder Panel 4 Nos + Bus coupler and adaptor panel) 19 Labour charges for transporting the 11 KV VCB Panel having 0.9m width 3m height and 2.5m length and weighing 1.5 tonne carefully from CDC Stores at Ambattur to newly proposed 33/11kV indoor SS at Airport staff Quarters, Chennai. including loading and unloading moving safely by use of cranes. This includes moving the package from inside the store shed to its ramp and inside to the substation control room. (Transformer Panel 2nos., Feeder Panel 8 nos., Bus Coupler and Bus Adopter) 20 Labour charges for marking on the floor and chipping of foundation holes in complete alignment embadding of channel for erection of breaker and grouting the 33kV VCBs. 21 Labour charges for marking on the floor and chipping of foundation holes in complete alignment embadding of channel for erection of breaker and grouting the 11kV VCBs 22 Labour charges for drawal of 33kV,1X630 Sq.mm, XLPE, UG, Cable from CDC Stores at Ambattur and Transporting to work site in lorry and laying the same in side duct from power transformer I &II to HV breaker I & II 23 Labour charges for drawal of 11kV,1X630 Sq.mm, XLPE, UG, Cable from CDC Stores at Ambattur and Transporting to work site in lorry and laying the same in side duct from power transformer I &II to LV breaker I & II 24 Labour charges for drawal of 1.1kV armoured copper control cable from CDC Stores at Ambattur and Transporting to work site in lorry and laying the same in side duct on G.I.Tray for SS equipments. 25 EARTHING ARRANGEMENTS 26 Labour charges for drawal of 40dia M.S rod from departmental stores and transporting to worksite inlorry (including loading & Unloading) and labour charges for auguring to a depth of 6mtr/20ft and fixing the M.S round rod 40mm dia board supply and making M.S Clamping arrangement in top of the rod and 4nos 12mm dia holes in clamp for inter linking of M.S. flats in any kind of soil and fixing with GEM and burried in ground and as directed by site in charge. (Ground Enhancement Material to be supplied by the contractor )(6m x 12Nos = 72mts) 27 Labour charges for drawal of M. S. flat of size. 50mm x 8mm from departmental stores and transporting to worksite in lorry (including loading & and Unloading) and labour charges for laying, cutting welding and painting of MS flat of size 50 x 8 mm and interconnecting . The plate should be burried at a depth of 2 feet depth or laid in duct as per site conditionand clamped out one meter Interval. M.S flat will be supplied by the board and painted with twin coat redoxide and enamal green paint before laying and as directed by site in charge. (as per drg.) 28 FABRICATION AND ERECTION OF GI TRAY 29 Fabrication and Supplyof GI Tray for the size of 300mm x 75mm for laying of control cables 30 Labour charges for erection of GI Tray for the size of 300mm x 75mm for control cables. 31 Anchor fast 32 Fabrication and Erection of L Clamp 33 ERECTION AND COMMISSIONING OF BATTERY 34 Erection of Battery, filling of acid and connecting the cables of the battery, Battery charger, AC and DC panels. 35 Battery initial charging, discharging and charging works 36 Transportation charges for Battery set from stores to company for initial charging and back to work site. 37 SUPPLY, ERECTION,TESTING & COMMMISSIONING OF FIRE ALARM & SMOKE DETECTOR 38 6 Zone Fire Alarm Control panel - 4 wire system. 39 Smoke Detector 40 2c x 1.5 sqmm un armoured copper control cable 41 Hooter. 42 Manual Call Point. 43 SUPPLY OF FIRE EXTINGUISHERS 44 25 Kg capacity Dry Chemical Powder Fire Extinguisher (Trolley Mounted) 45 9 Kg capacity Dry Chemical Powder Fire Extinguisher 46 6 kg capacity ABC type Fire Extinguisher 47 9 Lts capacity Foam type Fire Extinguisher(Stored Pressure Type) 48 Fire Bucket 10 Kg (for Water & Sand) 49 Fire buckets Stand. 50 T & PANDSCIENTIFIC INSTRUMENTS 51 Megger 1000V Make: Meco, Bosch 52 Multimeter AC o to1000 V Make: Meco, Bosch 53 Hot blower 500W Make: Meco, Bosch 54 Vaccum Cleaner -15Ltr Make: Meco, Bosch 55 Self supportAlu.Ladder(6 feet) Make: JEYES 56 Spanner Set(Ring, Double End, Socket set) Make: Taparia, Stanley 57 Steel clerks table with single drawer and cabinet on the right side of size42x24x30 Make:TANSI 58 SteelS type Chairwith arm. Make:TANSI 59 Steel Half Benchwith L top of size 36x15x18 Make:TANSI 60 SteelStoolof size 15x15x18 H Make:TANSI 61 Steel Side RackO Type with 4 shelves including Top and bottom forming 3 compartments of size 36x33x12Make:TANSI 62 Steelsenior plain cupboard with 4 shelves forming 5 compartments of size78x36x19 Make:TANSI 63 ELECTRIFICATION FOR CONTROL ROOM BUILDING 64 Providing point wiring for lights, fans, exhaust fans, yard lights, street lights, etc., using with 2 runs of 2.5 sq.mm FRLSH, single core, multistrand copper wire (one for phase and one for neutral) and with one run of 1.5sq.mm FRLSH, single core, stranded, copper wire for looped earthing (green colour) in not lessthan 2mm thick 25mm dia PVC conduit, ( ISI marked ) with necessary bends, tees, junction box and 3way ceiling rose etc., and including supplying and fixing 6A single pole flush type switch housed in manufacturers PVC / Zinc passivated surface box with cover plate. The 4 sq.mm FRLSH, single core, stranded, copper wire should be run from DB to switch boxes for running main Circuit. All the materials supplied should have ISI mark on it. The point rates quoted includes the cost of the materials and labour for wiring. Neutral wire for each point should be run individually from Switch board to point outlets. No looping of Neutral is allowed. Change of fittings, points for light and fan as per requirement of the site condition also to be done. The 4 sq.mm FRLSH, single core, stranded, copper wire should be run for pump motors from AC panel and switch board. Fan hooks wherever not provided the same to be provided. Fan points should be with electronic regulators. All terminations shall be made with suitable copper socket and identification ferrules must be provided in switch boxes, AC & DC panel boards. The height of the light fittings and ceiling fans shall be 2.5 mts. and 2.75mts from finished floor level reapectively or as directed by the engineer incharge. 65 Supply and providing wiring to twin tube light points, wall mounted points, ceiling points, yard light point, ceiling fan point, exhaust fan point etc., using with 2 runs of 2.5 sq.mm FRLSH, single core, multistrand copper wire (one for phase and one for neutral) and with one run of 1.5 sq.mm FRLSH, single core, stranded, copper wire for looped earthing (green colour) in not lessthan 25mm dia 2mm thick PVC rigid conduit, (ISI marked) with necessary accessories. including supplying and fixing of 6A modular switch housed in manufacturers PVC surface box with cover plate.The colour coding shall be followed. 66 1 point controlled by 1 switch for ceiling lights,yard lights, sign board lights, exhaust fans etc.,1. 1x18W LED Celling Light 2 Nos. 2. 2x20W Surface Light 5 Nos 31x100W LED Ceiling Light 5 Nos 4. Sign Board Light 3 Nos 5. Gate Light 2 Nos 6. Yard Light 7. Exhaust Fan5 Nos 67 same as item no.1 for 2 points controlled by 1 switch for Control room lights, street light etc., 1. 1x20W LED wall Tube Ligh 18 Nos 2. Street Light 08 Nos 68 same as item no.1 for ceiling fan point with stepped type electronic speed control 69 Supply and providing wiring to 6A plug point using two runs of 2.5 sq.mm PVC insulated FRLSH, single core,multistrand copper wire along with 1.5 sq.mm PVC insulated FRLSH, single core,multistrand copper wire for earthing and also including supplying and fixing of 6A modular switch and 6A 5pin socket housed in manufacturers PVC surface box with cover plate.The colour coding shall be followed. (6A Plug Point) 70 Supply and providing wiring toduct light, 5 lights controlled by one switch arrangements using two runs of 2.5 sq.mm PVC insulated FRLSH, single core,multistrand copper wire along with 1.5 sq.mm PVC insulated FRLSH, single core,multistrand copper wire for earthing in not lessthan 25mm dia 2mm thick GI rigid conduit, ( ISI marked ) with necessary accessories, including supplying and fixing of 6A modular switch housed in manufacturers PVC surface box with cover plate.The colour coding shall be followed. (Duct light point) 71 Supply and providing wiring to 6Nos Heater pointusing two runs of 4 sq.mm PVC insulated FRLSH, single core,multistrand copper wire along with 2.5 sq.mm PVC insulated FRLSH, single core,multistrand copper wire for earthing in not lessthan 25mm dia 2mm thickness GI rigid conduit, ( ISI marked ) with necessary accessories, including supplying and fixing of 16A modular socket controlled by 16A modular switch housed in manufacturers PVC surface box with cover plate at 5 height and connections and arrangements shall be made 3 points controlled by one circuit from AC panel. The colour coding shall be followed. ( Heater point) 72 Supply and wiring with 2 runs of 4 sq.mm PVC insulated FRLSH, single core,multistrand copper wire along with 1.5 sq.mm PVC insulated FRLSH, single core,multistrand copper wire for earthing in 2mm thickness PVC rigid conduit not lessthan 25mm dia for running circuit main from DB to all switch boxes. Neutral should not be looped. Neutral in black and earthing in green to be followed. 73 Supply and providing wiring to motor room points from motor to starter and switch boxes using two runs of 4sq.mm pvc insulated single core,multistrand FRLSH,copper wirecopper wire along with 2.5 sq.mm pvc insulated single core,multistrand FRLSH,copper wire for earthing inside the PVC rigid pipe not lessthan 25mm dia with 2mm wall thickness and also including supply and fixing of 16Amps double pole MCB switch with metal enclosure and connections. 74 Supply, installation, testing and commissioning of switch board and wiring 5runs of 4 sq.mm PVC insulated single core,multistrand FRLSH copper wire(R,Y,B,N&E) inside not lessthan 2mm thickness 25mm dia PVC rigid pipe and connections with 63A FP MCB with suitable metal enclosure for 2 Nos battery charger. (Battery charger Point) 75 Supply, installation, testing and commissioning of change over switch and wiring with 4runs of 4 sq.mm PVC insulated single core,multistrand FRLSH copper wire along with 1.5 sq.mm PVC insulated single core, multistrand FRLSH copper wire for earthing inside the PVC rigid pipe not lessthan 25mm dia with 2mm wall thickness and connections with 63A FP change over switch with suitable metal enclosure for 2nos battery charger. 76 Electrical light fixtures. 77 Supply, installation, testing and commissioning ofWall Mounted 1x20W LED Light fitting on suitable TW round block with necessary fixing accessories and connections Control room, Battery room and Toilet. 78 Supply, installation, testing and commissioning ofWall and Ceiling Mounted2x20W LED Light fitting on suitable TW round block with necessary fixing accessories and connections for Control room. 79 Supply, installation, testing and commissioning ofCeiling Mounted LED 1x20W Decorative surface Light fitting with necessary fixing accessories and connections for Toilet, Stair case entrance,etc., 80 Supply, installation, testing and commissioning of LED 1x10W Bulk head fitting with necessary fixing accessories and connections for Duct lighting 81 Supply, installation, testing and commissioning of water proofing LED 1x120W light fitting with necessary GI pipe and fixing accessories and connections for Tr.yard lighting. 82 Supply, installation, testing and commissioning of water proofing LED 1x100W light fitting with necessary GI pipe and fixing accessories and connections for Name board lighting. 83 Supply, installation, testing and commissioning of water proofing LED 1x25W street light fitting with necessary GI pipe and fixing accessories and connections for outside path way lighting. 84 Supply, installation, testing and commissioning of water proofing LED 1x25W Gate light fitting with necessary GI pipe and fixing accessories and connections for entrance. 85 Supply, installation, testing and commissioning ofCeiling Mounted LED 1x100W (2x2) Decorative surface Light fitting with necessary fixing accessories and connections for Control room. 86 Supply, installation, testing and commissioning of 1200mm (48) AC ceiling fan complete set with electronic regulator and suitable down rod at 3 mts above floor level with connections etc., 87 Supply, installation, testing and commissioning of 300mm (12) dia light duty AC Exhaust fan with necessary wall bracket, louver shutter arrangement, fixing accessories, making hole if necessary and connections for toilet. 88 Supply, installation, testing and commissioning of 450mm (18) dia heavy duty AC Exhaust fan with necessary wall bracket, louvers shutter arrangement, fixing accessories, making hole if necessarymaking hole if necessary and connections for control room and battery room. 89 Supply, testing and handing over the portable re-chargable 4W Emergency light 90 Supply, installation, testing and commissioning of 1000W Space Heater For panel heating purpose 91 AC Panel Board. This specification read in conjunction with general specifications covers the supply, installation, testing & commissioning of AC Panel Board suitable for 415V, 3 phase, 4 wire, 50Hz distribution system. The panel shall be IP 44,Free standing , Floor / Wall mounting , Vermin Proof , CRCAsheet metal enclosed, flush front with copper busbars, with 35 kA for 1 second rating , as per SLD,separate earth bus shall be provided throughout the length of the panel. The sheet steel fabricated panel made out of 14 SWG ( Shell & Door )/ 16 SWG ( Internal Partition ) CRCA Sheet steel fuly treateed by 7 tank process and powered coated with 60 to 70 Micron finish. only gavanised , zinc passivated hardware shall be used for assembely . The incoming and the outgoing feeder breakers, switch fuse units, change over switches, indicating lamps, meters etc., shall be accommodated in a modular multitier arrangement. A minimum of 400mm clearance shall be given from the floor level to the bottom most termination point. Adequate size cable alley & Busbar Chambers shall be provided with in the panel and at the back for easy bending and terminations. The outgoing feeders inside the panel shall be connected through solid busbars / Flexible cable links depending upon the current rating. Busbars shall be provided with PVC heat shrinkable sleeves . The panels shall be suitable for cable entry from top / bottom. Necessaary MS channel support & anchor fastner including all hardwares are included in the scope of electrical contractor. ( Please ref SLD enclosed ) 92 Supply, installation, testing & commissioning of AC Main Panel Board as per specification and drawings enclosed.The panel board comprises the followigs: 1. 100A, Bakelight Cut Out Fuse 6 nos 2. 100A, Neutral link 2 nos. 3. 100A Four Pole Change over switch 1 no. 4.Neon lamp indicator with control 9 nos 5.25sq.mm pvc insulated copper wire 10mts 6.25x4mm eletrolite copper flat5 Kgs 7.Voltmeter (0-500 V)1 No 8.Voltmeter selector switch1No 10.100A MCCB 25kA 1No 11. 63A TPN MCB 25kA1 No 12. 32A TPN MCB 25kA 6 Nos 13. 32A DP MCB10kA 3 Nos 14.16A SP MCB 10kA 12 Nos 15. Surge protection device1 No 16. Contactor 1 set 93 DC Panel Board. This specification read in conjunction with general specifications covers the supply, installation, testing & commissioning of DC Panel Board suitable for 110V, 3 wire distribution system. The panel shall be IP 44,Free standing , Floor / Wall mounting , Vermin Proof , CRCAsheet metal enclosed, flush front with copper busbars, with 35 kA for 1 second rating , as per SLD,separate earth bus shall be provided throughout the length of the panel. The sheet steel fabricated panel made out of 14 SWG ( Shell & Door )/ 16 SWG ( Internal Partition ) CRCA Sheet steel fuly treateed by 7 tank process and powered coated with 60 to 70 Micron finish. only gavanised , zinc passivated hardware shall be used for assembely . The incoming and the outgoing feeder breakers, switch fuse units, change over switches, indicating lamps, meters etc., shall be accommodated in a modular multitier arrangement. A minimum of 400mm clearance shall be given from the floor level to the bottom most termination point. Adequate size cable alley & Busbar Chambers shall be provided with in the panel and at the back for easy bending and terminations. The outgoing feeders inside the panel shall be connected through solid busbars / Flexible cable links depending upon the current rating. Busbars shall be provided with PVC heat shrinkable sleeves . The panels shall be suitable for cable entry from top / bottom. Necessaary MS channel support & anchor fastner including all hardwares are included in the scope of electrical contractor. ( Please ref SLD enclosed) 94 Supplying and fixing,testing & comissioning of DC Panel board as per specification and drawing enclosed. 1.63A DP MCCB 25kA 1No 2.63A HRC fuse with holder 2 nos 3. 150A copper bus bar 3 Nos 4.50 sq.mm FRLSH copper wire 4 mts 5. 10 sq.mmFRLSH copper wire 4 mts 6.Voltmeter (0-150V) 1 no 7. Voltmeter selector switch 1 no 8. 32A Bakelite connector 16 nos 9. 32A DP MCB 10kA 8 nos 10.Contactor 1 set 11. Neon lamp indicator with control 1 no 95 Supply and installation of 17.2mm dia 3Mt long low carbon steel earth electrode bonded with 250 micron copper with GI clamp to be installed in a suitable bore and filled with 50 Lbs of carbon bond envoirnment friendly back filling compound. An RCC trough of size 300x300mm shall be provided with RCC cover for protecting the electrode for AC and DC Panels. 96 FABRICATION OF 33KV BUS ADAPTER PANEL 97 Fabrication, Supply and Erection of 33KV bus adapter panel having a size900x1400x1400 mm using with 2.5mm thickness CRCA M.S. sheet. The adaptor box shall be painted with 7 tank process powder coating and color coating shall be Ivory/Siemens gray. The busbar rating shall be 2000A current rating electrolite copper bus bar each phase with 33kV class HS sleeves and supporting insulatorto interconnect the new 33KV VCB panel with existing 33kV VCB includingCutting,Welding, Brasing & Drilling and finishing. The erection of adaptor work shall be executed under LC and co.ordinated with the engineer incharge. (At source end Airport staff Quarters) 98 GST For bidders within Tamil Nadu Note: Builders within Tamil Nadu shall enter values seperately for SGST and CGST and shall enter the value as Zero for IGST
Contract Date : 20 Dec, 2025   |   Contract Value : 17.81 Lakhs
BRR : 9355489 Design, Engineering, Manufacture, Survey, Supply, Transportation, Erection, Testing & Commissioning of 1x6.3 MVA, 33/11KV Receiving Station including 33 KV Line at GMC Associate Hospital Rajouri on Turnkey Basis.” under the jurisdiction of Executive Engineer, Sub Transmission Division KALAKOTE, JPDCL Jammu- 1 33 KV LINE BAY OF SINGLE BUS SCHEME (2 Nos); (INCLUDING ALL CIVIL WORKS& EARTHING OF EQUIPMENTS AS DIRECTED BY THE ENGINEER INCHARGE) 2 SITC OF SUB‐STATION MAIN EQUIPMENT 3 33 KV Vacuum Circuit Breaker (36 kV, 1250A, 26.2 kA, Outdoor Type)with allied accessories and heavy duty pad clamps. 4 33kV C&R Panel along withO/C, E/F relays, mimic diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Smart meter -5 Amps with RS-485 port, DLMS Compliant with RS-485 port 5 33 kV Isolator With Earthing Blade with allied accessories and pad clamps(36kV,1250A, Outdoor,3 poles, 25 kA) with multi fingered female contacts with tin coated contacts, The isolator is to be provided a locking arrangement for un-authorized operation and auxilliary switch box (set of 3 Nos.). 6 33 kV Isolator Without Earthing Blade with allied accessories and pad clamps(36kV,1250A, Outdoor,3 poles, 25 kA) with multi fingered female contacts with tin coated contacts, The isolator is to be provided a locking arrangement for un-authorized operation and auxilliary switch box (set of 3 Nos.). 7 33 kV Current Transformer (33 kV, 1Φ, Multi Ratio Multi Core, Outdoor) (1 No. per Φ) 8 33 kV Voltage Transformer (33 kV/110 V, 1Φ, Multi-Core, Outdoor), (1No. per Φ) 9 30 kV Lightening Arrestors (30 kV, 10kA, Station class, ZnO, Polymer) gap less 10 33 kV Polymer Post Insulator36kV,170kV Impulse, creepage distance 1224m 11 SITC OF GI STEEL STRUCTURES 12 Nominal Bore 200, 5.9 mm Thick 13 Galvanised Steel Structures 14 Galvanised Nuts & Bolts 15 SITC OF CONTROL CABLES 16 Supply, Laying, Testing & Commissioning of 12 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI,FRLS as per relevant Standards 17 Supply, Laying, Testing & Commissioning of 04Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI,FRLS as per relevant Standards 18 Supply, Laying, Testing & Commissioning of 02 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI,FRLS as per relevant Standards 19 Lugs, Ferrules etc. 20 SITC OF CONDUCTOR & HARDWARE 21 Providing & Fixing 200 mm² ACSR Conductor Panther 22 Providing & Fixing of 630A T-clamps suitable for 0.2 ACSR Conductor having 8 no,s GI bolts of 19mm thick, as per relevant Standards 23 Providing & Fixing of Aluminium Tention Fittings of 0.2 ACSR Conductor having 8 no,s GI bolts of 19mm thick, as per Relevant Standards 24 Providing & Fixing Polymeric composite Disc Insulator 36KV, Lightening Impulse 170kV Positive and 180kV Negative, creepage distance 900mm,min failing load 70kN 25 GI Earth wire 7/4.00 mm sq. 26 Providing & Fixing of GI flat for earthing 50x6mm with epoxy insulator along with clampsas per relevant Standards 27 COST FOR 33 kV TRANSFORMER BAY OF SINGLE BUS SCHEME (INCLUDING ALL CIVIL WORKS& EARTHING OF EQUIPMENTS AS DIRECTED BY THE ENGINEER INCHARGE) 28 SITC OF SUB‐STATION MAIN EQUIPMENT 29 33 KV Vacuum Circuit Breaker (36 kV, 1250A, 26.2 kA, Outdoor Type) with allied accessories and heavy duty pad clamps. 30 33 kV Isolator with Without Earthing Blade with allied accessories and pad clamps(36kV,1250A, Outdoor,3 poles, 25 kA) with multi fingered female contacts with tin coated contacts, The isolator is to be provided a locking arrangement for un-authorized operation and auxilliary switch box (set of 3 Nos.). 31 33 kV Current Transformer (33 kV, 1Φ, Multi Ratio Multi Core, Outdoor) (1 No. per Φ) 32 30 kV Lightening Arrestors (30 kV, 10kA, Station class, ZnO, Polymer) gap less 33 33 kV C&R Panelalong with O/C, E/F and differential relays (IEC61850), mimic diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Smart meter -5 Amps, DLMS Compliant with RS-485 port 34 33 kV Post Insulator Polymer 36kV,235kV Impulse, creepage distance 1224m 35 SITC OF GI STEEL STRUCTURES 36 Nominal Bore 200, 5.9 mm Thick 37 Galvanised Steel Structures 38 Galvanised Nuts & Bolts 39 SITC OF CONTROL CABLES 40 12 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS. 41 6 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS. 42 2 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS. 43 Lugs, Ferrules etc. 44 SITC OF CONDUCTOR & HARDWARE 45 Providing & Fixing 200 mm² ACSR Conductor Panther 46 Providing & Fixing of 630A T-clamps suitable for 0.2 ACSR Conductor having 8 no,s GI bolts of 19mm thick, as per relevant Standards 47 Providing & Fixing of Aluminium Tention Fittings of 0.2 ACSR Conductor having 8 no,s GI bolts of 19mm thick, as per Relevant Standards 48 Providing & Fixing Polymeric composite Disc Insulator 36KV, Lightening Impulse 170kV Positive and 180kV Negative, creepage distance 900mm,min failing load 70kN 49 Providing & Fixing of GI Earth wire 7/4.00 mm sq, with 4Nos. 13mtr long ST Poles for Shielding of 33KV Yard along with Power Transformer with proper earthingby GI Pipe 40 mm or G.I Rod 20mm, 3.0 mtr long through welded with GI Strip 25x3 mm 50 Providing & Fixing of GI flat for earthing 50x6mm with epoxy insulator along with clampsas per relevant Standards 51 SITC of 6.3 MVA 33/11KV Power Transformer; (INCLUDING ALL CIVIL WORKS& EARTHING OF EQUIPMENTS AS DIRECTED BY THE ENGINEER INCHARGE) 52 6.3MVA 33/11kV, ONAN, Copper wound, Out-door Type, conventional Power Transformer, Oil Filled with OLTC and all accessories including HT and LT Terminal connections and Tertiary Winding. 53 Providing & Fixing of Al Bus bars for transformer terminals of suitable size with color coding, heat shrinkable sleeves covered including drilling, welding etc as per requirement to be fixed on LV side of transformer as per relevant Standards 54 Providing & Fixing of GI Earth wire 7/4.00 mm sq, with 4Nos. 13mtr long ST Poles for Shielding of 33KV Yard along with Power Transformer with proper earthingby GI Pipe 40 mm or G.I Rod 20mm, 3.0 mtr long through welded with GI Strip 25x3 mm 55 12 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS. 56 6 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS. 57 2 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS. 58 COST FOR 11 kV INDOOR SWITCHGEAR OF 6.3MVA, 33/11 KV SUBSTATION; (INCLUDING ALL CIVIL WORKS& EARTHING OF EQUIPMENTS AS DIRECTED BY THE ENGINEER INCHARGE) 59 11 kV VCB Panel Board (12 kV, 1250A, 25 kA, Outdoor) with O/C, E/F relays (IEC61850), Mimic Diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Tri-vector meter -5 Amps, DLMS Compliant with RS-485 port (1+4)SET 60 11kV, Gapless Surge Arrestor,9 KV ,10 KA ,LA with Polymer housing, Stn. Type (4/5/6 Sets) 61 11 kV3- Core XLPE 400 mm² armoured, FRLS 62 11 kV3-Core XLPE 120 mm² armoured, FRLS 63 11 kV Indoor Heat Shrinkable Cable Termination Kits 64 11 kV Outdoor Heat Shrinkable Cable Termination Kits 65 11 kV Indoor Heat Shrinkable Cable Termination Kits 66 11 kV Outdoor Heat Shrinkable Cable Termination Kits 67 11 kV Isolator, double break,3-pole, 600Amp, horizental mounting Type, with Earth Switch. 68 11 Mtr. Long Pole (ST-410 SP56) 69 9 Mtr. Long Pole(ST-410 SP33) 70 33kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp 71 33kV HGF Set 3-Phase, 3-Pole, 200 Amp 72 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp 73 Galvanisedironof sorts including CH Angle brases Clamps etc. 74 100 KVA, 33/0.04 KV, 3-Phase Distribution Transformer with Bimetallic Terminal connectors Energy Level -2 (Copper wound) (1No. Spare) 75 120 mm²PVCLT Cable 4 Core, armoured, FRLS 76 Cement bottoming 1:2:4 mix as per REC standards 0.5cum per pole 77 Earthing of 100 KVA Substation-Excavation of earht pit of dia 650 mm & depth 3000 mm installation of earthing pipe of 40 mm Nominal bore & 4 mm wall thickness & length 2.5 mtr long as per IS 1239 GI Strip[ for neutral earthing of size 75 mm x 10 mm & 50 mm x6 mm for connection of transformer body, G.O set & lightening arrestor as per IS 2629/85, GI Nuts & Bolts, refilled with earth enhancement materials and earth chamber made of brick masonary with RCC slab cover. 78 Supply ,Installation Testing and Commissioning of Earthing Complete by GI Pipe 40 mm or G.I Rod 20mm, 3.0 mtr long through welded with GI Strip 25x3 mm. 79 11kV Bus Bar Fuse Set Out Door type for Auxilary Transformer 80 COMMON MISCELLENOUS WORKS IN 33/11kV SUBSTATIONS; (INCLUDING ALL CIVIL WORKS& EARTHING OF EQUIPMENTS AS DIRECTED BY THE ENGINEER INCHARGE) 81 Compound wall of Receiving Station By way of mass concreting in foundations and 228mm brick wall of 2 m height including main gate and allied works 82 G.I Chainlink Fencing of 33kv yard by way of mass concreting in foundations and chainlink fencing of 6 ft height using G.I Angle of size 65x65x6mm and G.I Flat iron 50x6mm 83 RCC Cable Duct for laying of 11 KV XLPE Cable from Power transformer to Control Room and Control Room to O/G Structures as per REC Approved Standard Drawing. 84 33/11 kV RCC Power Transformer Foundation (1:2:4) as per REC Approved Standarddrawing foundation complete job for 3.15 MVA Power Transformer 85 33 kV RCC Equipment foundation and Gantry foundationas per REC Approved Standarddrawing (VCB, Isolators, CTs, PIs, LAs etc) complete job 86 Earthing Mat using ( GI Flat 75 x 8mm) and (GI earth rod spikes 2.5 m long 20 mm dia), yard area, as per REC Standerd 87 Earthing Electrode ( 3m long 40mm dia GI pipe) through GI strip (50x6)mm for equipments 88 33 kV Yard concreting and metalling, yard area by providing, supply & laying 100mm thick PCC 1:4:8 using 20mm normal course aggregating and spreading 100mm three layer of 20mm single sized crushed/broken stone, as per REC Standerd 89 Borewell 125mm dia and 100mtr in depth with 2HP Submersible Pump including distribution complete job. 90 BUILDING: A. Control Room Building on ground floorcomplete with Column and Beam structures with 1 no J.E. Room , 1 Store room, 1 Battery Room and a main hall including a luminium windows, cable ducts for power and control cable, Toilet (completewith WC, Washbasin and fittings), electric fittings(fans, LEDtubelights, leds powerpoints and o ther fixtures) 2 coat of putty with Priming coat and Reputed Colour of 2 coats to the entire building as per the direction of concerned engineer , painting of doors and windows etc. Overhead water Storage tanks . Water Supply . Septic Tank complete with Sanitary Fittings including kota stone floor. including RCC slab in furnished conditioncomplete in all respects.(Note: The Contractor shall submit the building drawing in all respects i.e. structural / architectural prepared by authorized Architect for approval from the dept for execution of works.) 91 BUILDING:B. Staff Quarters on 1st floor with Column and Beam structures includingToilets (completewith WC, Washbasin and fittings), electric fittings(fans, LEDtubelights, leds powerpoints and other fixtures of reputed make) Putty of 2 coats , Priming 2 coatsand reputed colour as directed by concerned Engineer to the entire buildingComplete in all respect painting of doors and windows etc. Overhead water Storage tanks . Pantry Room with all the Fittings. Water Supply . including Tile and marble flooring with periphet and Stairs Complete, two room complete with beding chair etc. as per the direction of engineer incharge.(Note: The Contractor shall submit the building drawing in all respects i.e. structral / architechuralprepared by authorised Architect for approval from the dept for execution of works.) 92 Development of land by removing weeds, wild grass and endulation if any, ornamental land scaping and growing of ornamental trees in unbuilt areas/road sides and Construction of approach path by Way of Cement concreteing/ Interlocking tiles/blacktopping including drains complete. 93 SITC of 120 Watts LED Street lights of following watts IP-66/67 protected with lens type LED, Pressure Di-cast aluminium body , 100+ LM/watt, Input voltage AC 85-265 Volts, efficacy 92%, life time more than 45000 Hrs. ( Crompton, Phillips, Jaguar, GE). To be mounted on 13mtr ST Poles including necessaryboxes/fabrication/modification as per requirement. ( the LED lights brand must have conducted the indian photometic test certificate of LM-79 and 80.) 94 COMMON MISCELLANEOUS EQUIPMENTS 33/11kV SUBSTATIONS; (INCLUDING ALL CIVIL WORKS& EARTHING OF EQUIPMENTS AS DIRECTED BY THE ENGINEER INCHARGE) 95 a). Battery Bank 30 V,100 AH , of 15 No. cells of 2 V each, sealed maintenance free VRLA type,High impact Polyprophelenecopolymer container,flame retardant. b). 30V,100 AH , Float-Cum-Boost Charger With Full wave rectification for 220 V, 1Phase, 50 HZ AC Input Supply . 96 Distribution Panel (30 V, DC) made of CRCA thickness not less than 2mm. Powder Coated, degree of protection IP43 for 2 No battery incoming supply with 2 No 63 Amps DP MCBs for incoming supply Doublebusbar of adequate size, 12 No DP DC MCB (0-32A) including indication lamps and cables and other accessories 97 Distribution Panel (415 V, AC) made of CRCA thickness not less than 2mm. Powder Coated, degree of protection IP43. 200 Amps Switch Fuse disconnector for incoming supply and 5 No TPN MCBs (16-125 Amps ) and 5 No DP MCBs (0-32A), rectangular busbar suitable for 200 Amps continuous Supply including indication lamps and cables and other accessories 98 Providing of Bolt cutter of Taparia make BC-42 with allied accessories. 99 Providing of Rubber Mat 1mx2m 19mm thick 100 Providing of Fire ExtingiusherCo₂/ABCType of 4.5 kg capacity for controlroom 101 Providing of 3Sand Bucket Fire Extingiusherwith metallic stand andidentification plates 102 Providing of Industrial safety Helmet 103 Providing of Rubber Gloves for 33 kV level 104 Providing of Rubber Gloves for 11kV level 105 Providing of Industrial Safety Belt with comfort foam reinforment 106 Providing of Safety volcanized rubber Shoes 107 Providing of Telescopic Cabron fibre Earthing rod (set of 3 rods) 108 Providing of HV Detectors all voltages with fibre rod 109 Providing of Chrome vanadium forged Spanners of 10mm to 32mm sizering/u shaped. (set of 10 No.s) 110 Providing of Forged Adjustable wrench of 22mm and 32mm size 111 Providing of Screw drivers setflat cum star bit type dual end (set of 8 no.sof different sizes) 112 Providing of Nose Plier 113 Providing of Normal Plier 114 Providing of Sledge hammer of 2Kg with handle 115 Providing of forged Chisel long shank type 116 Providing of HSS Cabron steel Hack saw with frame and set of 6 blade withtwo sided teeths 117 Providing of Measuring tape of 12 feet spring loaded 118 Providing of Precise 1 feet long bubble based water level 119 Providing of 600 watt hand drill with drill bits of HSS Hammer type 120 Providing of Tool Kit case plastic of Harry-kerry make of 2.5x1x1.5 feetdimensions with different chambers 121 Providing of Clamp meter with multi measuring parametersMarkoni/motwane/fluke make 122 Providing of Screw driver tester neon lamp based 123 Providing and fixing of industrial heavy duty chain block of 1 Ton capacitywith allied accessories complete 124 Providing of Chrome make socket set with ratchet and extension bars of10mm-32mm size sockets with allied accessories 125 Providing of Aluminum industrial ladder split 40 feet extension type withallied accessories 126 Providing of foldable multi-purpose aluminium ladder 127 Office Steel Chairs wih Armrest 128 Office Table of Standard Size with Sufficient Drawers 129 Office Almirah With Locker of reputed make 130 Cost of Installation of Capacitor Bank (INCLUDING ALL CIVIL WORKS& EARTHING OF EQUIPMENTS AS DIRECTED BY THE ENGINEER INCHARGE) 131 11 KV Capacitor bank 2.4MVAR with VCB Panel with complete arrangement for connection with 11 KV incomer panel, Series Reactor, Isolator, RVT, Surge Arrestor, HT Cable with termination Kits, Control Cables, CRCA Cubicle Panel etc with Structure, foundation and accessories. 132 SITC OF 33 KV LINE 133 11 Mtr. Long Pole (ST-410- SP56) 134 GI V cross-arm with top Bracket including clamps 135 GI Channel X-Arm including clamps and braces 136 GI Wire SSS 137 100 mm² AL59 Aluminium Claded Steel Conductor 138 PG Clamps for 100mm² ACSR Conductor 139 Tension Clamps with bail & IPC (Insulation Piercing Conductors) 140 Alignment Ties 141 IPC (Insulation Piercing Conductors) from bare to CC (Covered Conductor) 142 IPC from CC to CC Connection 143 IPC with Aluminium bail for Earthing 144 Mid Span Joint 145 33 kV Isolator without Earthing Blade (36kV, 2500A, Outdoor, 3 poles, 25 kA) 146 33kV Polymeric composite Pin Insulator 36kV, 10kN,Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm 147 33kV Polymeric composite Disc Insulator 36KV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm with fitting 148 Galvanized Nuts and Bolts. 149 Danger Plates with Clamps 150 Anti-Climbing Device with Clamps 151 Earthing Complete by GI Pipe 40 mm or GI Rod20mm, 3 mtr long through GI Strip. 152 Red Oxide 153 Aluminium Paint 154 Cement bottoming for 11 Mtr Long ST Pole, 0.78 Cum/Pole 155 Galvanised Stay Set with 50 x 8 mm stay clamp, guy insulator(2Nos.), anchor plate (300x 300 x 8 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 20 mm diameter solid GS stay rod & 7/4.00 mm dia GI stranded wire complete 156 SITC OF 11 kV LINE 157 8 Mtr. Long Pole( ST-410 SP15) 158 GI V cross-arm with top Bracket including clamp 159 GI Channel X-arm including clamps and braces 160 50 mm² ACSR Conductor 161 PG Clamps for 50 mm² ACSR Conductor 162 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm 163 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm 164 Galvinized Nuts and Bolts 165 Danger Plates with Clamps 166 Anti-Climbing Device with Clamps 167 Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. 168 Red Oxide 169 Aluminium Paint 170 Cement bottoming 1:2:4 mix as per REC standards .45cum /pole 171 Aluminium Jointing Sleeves 172 Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Contract Date : Ref. Documents   |   Contract Value : Ref. Documents
BRR : 9231122 Construction Of 220Kv Gis Substation, Sector-75A, Gurugram -- 1 220kV SystemThe 245kV SF6 gas insulated switch gear for three phase system shall have double bus bar arrangement with 7 bays (2 No. 100MVA 220/33kV transformer bay, 1 no. bus-coupler and 4 nos. feeder bays). Space for future 1 No. transformer bay and 2 No. Line bays and jointing plugs shall be kept in GIS hall for adding future bays and jointing plugs required for connecting GIS of different makes. The SF6 gas insulated switch gear rated for 220kV, 3-phase, 50 HZ 50kA fault level shall be of the indoor metal-enclosed type, comprising of following items.245kV, 2000A, single 3 – ⏀ or three 1 –⏀SF6 gas insulated, metal enclosed Bus bar arrangement, consisting of 2000Asingle 3 – ⏀or three 1 – ⏀ SF6 gas insulated switchgears, each Bus Bar comprising of:-i) Bus bar enclosures running the length of the switchgear to interconnect each of the circuit breaker bay modules in double main bus system.ii) Three, 2-core, single phase or single 3 – ⏀ ,2 core each phasevoltage transformers/ PTs.iii) 2000A, One 3 – ⏀or three 1 –⏀ , single pole, group operated isolator/disconnector with one, 3 – ⏀or three 1 –⏀, single pole, group operated earthing switch with manual and motor driven operating mechanisms.iv) 2000A, One high speed 3 – ⏀or three 1–⏀ , single pole, group operated earthing switches, complete with manual and motor driven operating mechanisms.v) Each GIS compartment with gas monitoring device, pressure switch etc. as required.vi) Terminal boxes/ Local Control Cubicle.vii) Interconnecting wiring/ piping.viii) Grounding, support structures and platforms. 2 245kV, 2000A, single 3 – ⏀or three 1 –⏀ , Bus coupler bay module, consisting of 2000Asingle 3 – ⏀or three 1 –⏀SF6 gas insulated switchgears, comprising of:i) 2000A, One 3 – ⏀or three 1 – ⏀ , SF6 gas insulated circuit breaker, complete with operating mechanism.ii) Three, 5-core, single phase current transformers (1200-800-400/1-1-1-1-1A)iii) 2000A, Two sets of single pole, group operated isolator/disconnector switches each with single pole, group operated earthing switch and complete with manual and motor driven operating mechanisms.iv) Each GIS compartment with gas monitoring device, pressure switch etc. as required.v) Terminal boxes/ Local Control Cubicle.vi) Interconnecting wiring/ piping.vii)Grounding, support structures and platforms. 3 245kV, 1250A, single 3 – ⏀or three 1 –⏀ , Transformer feeder circuit breaker bay module,consisting of 1250Asingle 3 – ⏀or three 1 – ⏀SF6 gas insulated switchgears, for transformer, each comprising of:-i) 1250A, One 3 – ⏀or three 1 –⏀ , SF6 gas insulated circuit breaker, complete with operating Mechanism.ii) Three, 5-core, single phase current transformers (450-300/0.577-1-1-1-1A)iii) 1250A, One 3 – ⏀or three 1 –⏀ , single pole, group operated isolator/disconnector without earthing switch, complete with manual and motor driven operating mechanisms.iv) 1250A, One 3 – ⏀or three 1 –⏀ , single pole, group operated isolator/disconnector with one 3 – ⏀or three 1 –⏀ , single pole, group operated earthing switch, complete with manual and motor driven operating mechanisms.v) 1250A, One 3 – ⏀or three 1 –⏀ , single pole, group operated isolator/disconnector with two earthing switches each comprising of one 3 – ⏀or three 1 – ⏀ , single pole, group operated earthing switches complete with manual and motor driven operating mechanisms.vi) Each GIS compartment with gas monitoring device, pressure switch etc. as required.vii)Terminal boxes/ Local Control Cubicle.viii) Interconnecting wiring/ piping.ix) Grounding, support structures and platforms. 4 245kV, 1250A, single 3 – ⏀or three 1 –⏀ , Transmission line feeder circuit breaker bay modules, consisting of 1250Asingle 3 – ⏀or three 1 –⏀SF6 gas insulated switchgears, each comprising of:-i) 1250A, One 3 – ⏀or three 1 – ⏀ , SF6 insulated circuit breaker, complete with operating mechanism.ii) Three, 5- core, single phase current transformers (1200-800-400/1-1-1-1-1A)iii) 1250A, One 3 – ⏀or three 1 – ⏀ , single pole, group operated isolator/disconnector without earthing switch, complete with manual and motor driven operating mechanisms.iv) 1250A, One 3 – ⏀or three 1 – ⏀ , single pole, group operated isolator/disconnector with one, 3 – ⏀or three 1 – ⏀ , single pole, group operated earthing switch, complete with manual and motor driven operating mechanisms.v) 1250A, One 3 – ⏀or three 1 – ⏀ , single pole, group operated isolator/disconnector with one normal and one high speed 3 – ⏀or three 1 – ⏀ , single pole, group operated earthing switches, complete with manual and motor driven operating mechanisms.vi) Each GIS compartment with gas monitoring device, pressure switch etc. as required.vii)Terminal boxes/ Local Control Cubicle.viii) Interconnecting wiring/ piping.ix)Grounding, support structures and platforms. 5 a) 220kV XLPE Copper cables (4X1CX400mm2) to connect 220kV side of 100MVA Transformer with GIS(approx.) 6 b) Termination kit at both ends for 220kV XLPE Copper cables (1CX400mm2). (Termination Kit for (GIS/AIS) both ends along with all accessories constitute a set for each cable) 7 a) 220kV XLPE Copper cables (4X1CX1000mm2) to connect 220kV transmission line feeders with GIS (approx.) 8 b) Termination kit at both ends for 220kV XLPE Copper cables (1CX1000mm2) (Termination Kit for (GIS/AIS) both ends along with all accessories constitute a set for each cable) 9 Ventilation system (AHU) to accommodate in designated room in GIS hall as per Annexure-V as it is already an integral part of the ventilation system 10 33kV SystemThe 36kV SF6 Gas Insulated Switchgear for three phase system shall have single bus bar arrangement with 26 bays (4 No. Transformer I/C bays from two 100MVA Transformers, 2 No. bus-sectionalizer bays, 16 nos. feeder bays, 2 No. T/F bays for Auxiliary Supply and 2 No. Capacitor bank bays). Space for 12 Nos. future bays (2 No. I/C of 220/33kV T/F bay, 8 No. line bays and 1 No. capacitor bank, 1 No. bus-sectionalizer bay for future) shall be kept in GIS hall for adding future bays and jointing plugs required for connecting GIS of different makes. The SF6 Gas Insulated Switchgear rated for 33kV, 3-phase, 50Hz, 31.5kA for 3 sec. fault level shall be of the indoor metal-enclosed type, comprising of following items. 36kV, 2000A,single 3 – ⏀ or three 1 –⏀, SF6 gas insulated, metal enclosed bus bars arrangement, consisting of 2000Asingle 3 – ⏀ or three 1 –⏀ SF6 gas insulated switchgears, each Bus Bar comprising of (single bus for each T/F with bus sectionaliser) :- i) Bus bar enclosures running through the length of the switchgear to interconnect each of the circuit breaker bay modules in single bus system.ii) Each GIS compartment with gas monitoring device, pressure switch etc. as required.iii) Terminal boxes/ Local Control Cubicle consisting of all protection relays, mechanism control system, indication system etc.iv) Interconnecting wiring/ piping.v) Grounding, support structures and platforms. 11 36kV, 2000A,single 3 – ⏀ or three 1 –⏀, SF6 gas insulated, metal enclosed bus sectionaliser, consisting of 2000Asingle 3 – ⏀ or three 1 –⏀ SF6 gas insulated switchgears, each Bus Sectionaliser comprising of :(1 for each T/F) i) 2000A, One 3 – ⏀ or three 1 – ⏀, SF6 gas insulated vaccum circuit breaker, complete with operating mechanism for sectionaliser bay.ii) Three, single-core, single phase current transformers (2000-1000/5A)iii) Two sets of 2000A, two 3 – ⏀ or three 1 – ⏀, single pole, group operated isolator/disconnector with one, 3 – ⏀ or three 1 – ⏀, single pole, group operated earthing switch, complete with manual and motor driven operating mechanisms.iv) Two sets of Three, 2-core, single phase or single 3 – ⏀, 2 corevoltage transformers/ PTs.v) Two sets of 2000A, One 3 – ⏀ or three 1 – ⏀, single pole, group operated isolator/disconnector with one, 3 – ⏀ or three 1 – ⏀, single pole, group operated earthing switch with manual and motor driven operating mechanisms.vi) Two sets of 2000A, high speed 3 –  or three 1 – , single pole, group operated earthing switches, complete with manual and motor driven operating mechanisms.vii) Each GIS compartment with gas monitoring device, pressure switch etc. as required.viii) Terminal boxes/ Local Control Cubicle consisting of all protection relays, mechanism control system, indication system etc.ix) Interconnecting wiring/ piping.x) Grounding, support structures and platforms 12 36kV, 2000A, single 3 – ⏀ or three 1 –⏀, Incomer transformer bay modules, consisting of 2000Asingle 3 – ⏀ or three 1 –⏀ SF6 gas insulated switchgears, for 100MVA, 220/33kV transformers, each comprising of: - (2 for each T/F) i) 2000A, One 3 – ⏀ or three 1 – ⏀, SF6 gas insulated vaccum circuit breaker, complete with operating mechanism for incomer bay from 220/33kV transformer.ii) Three, 4-core, single phase current transformers (2000-1000/0.577-5-5-1A)iii) 2000A, Two 3 – ⏀ or three 1 – ⏀, single pole, group operated isolator/disconnector with one, 3 – ⏀ or three 1 – ⏀, single pole, group operated earthing switch, complete with manual and motor driven operating mechanisms.iv)2000A, One 3 – ⏀ or three 1 – ⏀, single pole, group operated isolator/disconnector with two earthing switches each comprising of one 3 – ⏀ or three 1 – ⏀, single pole, group operated earthing switches complete with manual and motor driven operating mechanisms.v) Each GIS compartment with gas monitoring device, pressure switch etc. as required.vi) Terminal boxes/ Local Control Cubicle consisting of all protection relays, mechanism control system, indication system etc..vii) Interconnecting wiring/ piping.viii)Grounding, support structures and platforms.ix) Set of Surge Arrestors & Voltage Detectors 13 36kV, 630A, single 3 – ⏀ or three 1 –⏀, Transmission line feeder circuit breaker bay modules, consisting of 630Asingle 3 – ⏀ or three 1 –⏀ SF6 gas insulated switchgears, each comprising of:- (8 for each T/F) i) 630A, One 3 – ⏀ or three 1 –⏀, SF6 gas insulated vaccum circuit breaker, complete with operating mechanism for outgoing feeder.ii) Three, 3-core, single phase current transformers (600-300/5-1A)iii) 630A, One 3 – ⏀ or three 1 – ⏀, single pole, group operated isolator/disconnector with one, 3 – ⏀ or three 1 – ⏀, single pole, group operated earthing switch, complete with manual and motor driven operating mechanisms.iv) 630A, One 3 – ⏀ or three 1 – ⏀, single pole, group operated isolator/disconnector with one normal and one high speed fault make 3 – ⏀ or three 1 – ⏀, single pole, group operated earthing switches, complete with manual and motor driven operating mechanisms.v) Each GIS compartment with gas monitoring device, pressure switch etc. as required.vi) Terminal boxes/ Local Control Cubicle consisting of all protection relays, mechanism control system, indication system etc.vii) Interconnecting wiring/ piping.viii) Grounding, support structures and platforms.ix) Set of Surge Arrestors & Voltage Detectors 14 36 kV, 630A, 31.5 kA for 3 sec, SF6 gas insulated Capacitor Bay Modules, consisting of 630A single 3 – ⏀ or three 1 –⏀, SF6 gas insulated switchgears, each comprising of:- (1 for each T/F)i) 630A, One 3 – ⏀ or three 1 –⏀, SF6 gas insulated vaccum circuit breaker, complete with operating mechanism for outgoing feeder.ii) Three, 3-core, single phase current transformers(400-300/5-5A)iii)630A, One 3 – ⏀ or three 1 – ⏀, single pole, group operated isolator/disconnector with one, 3 – ⏀ or three 1 – ⏀, single pole, group operated earthing switch, complete with manual and motor driven operating mechanisms.iv) 630A, One 3 – ⏀ or three 1 – ⏀, single pole, group operated isolator/disconnector with one normal and one high speed fault make 3 – ⏀ or three 1 – ⏀, single pole, group operated earthing switches, complete with manual and motor driven operating mechanisms.v) Each GIS compartment with gas monitoring device, pressure switch etc. as required.vi) Terminal boxes/ Local Control Cubicle consisting of all protection relays, mechanism control system, indication system etc.vii) Interconnecting wiring/ piping.viii) Grounding, support structures and platforms.ix) Set of Surge Arrestors & Voltage Detectors 15 36 kV, 630A, 31.5 kA for 3 sec, SF6 gas insulated S/Stn Transformer Bay Modules, consisting of 630A single 3 – ⏀ or three 1 –⏀, SF6 gas insulated switchgears, each comprising of:- (1 for each T/F) i) 630A, One 3 – ⏀ or three 1 –⏀, SF6 gas insulated vaccum circuit breaker, complete with operating mechanism for outgoing feeder.ii) Three, single phase 2-core current transformers (60-30/5-1A)iii) 630A, One 3 – ⏀ or three 1 – ⏀, single pole, group operated isolator/disconnector with one, 3 – ⏀ or three 1 – ⏀, single pole, group operated earthing switch, complete with manual and motor driven operating mechanisms.iv) 630A, One 3 – ⏀ or three 1 – ⏀, single pole, group operated isolator/disconnector with two earthing switches each comprising of one 3 – ⏀ or three 1 – ⏀, single pole, group operated earthing switches complete with manual and motor driven operating mechanisms.v) Each GIS compartment with gas monitoring device, pressure switch etc. as required.vi)Terminal boxes/ Local Control Cubicle consisting of all protection relays, mechanism control system, indication system etc.vii) Interconnecting wiring/ piping.viii) Grounding, support structures and platforms.ix) Set of Surge Arrestors & Voltage Detectors 16 33kV XLPE copper Cable (6X1Cx1000mm2) for connecting 33kV side of each I/C of 220/33kV transformer with GIS. (Two cables shall be used in each phase for each I/C, i.e. 2 Runs per phase x 3 no. Phase x 4 no. I/C) (approx.) 17 Single phase Termination kit for both end for 33kV XLPE copper Cable (1cx1000mm2)(Termination Kit for (GIS/AIS) both ends along with all accessories constitute a set for each cable) 18 33kV XLPE copper Cable (3cx300m2) for connecting 33kV capacitor bank bay(approx.) 19 Three phase Termination kit for both end for 33kV XLPE copper Cable (3cx300mm2) (Termination Kit for (GIS/AIS) both ends along with all accessories constitute a set for each cable) 20 33kV XLPE copper Cable (3cx95mm2) for single ckt. for station transformer(approx.) 21 Three Phase Termination kit for both end for 33kV XLPE copper Cable (3cx95mm2)(Termination Kit for (GIS/AIS) both ends along with all accessories constitute a set for each cable) 22 100 MVA 220/33 kV Power T/F along with10% extra T/F oil 23 NIFPES for 220/33 kV Power T/F 24 220 kV Surge Arrestor 25 33 kV Surge Arrestor (Including Capacitor Bank) 26 220 kV NCT (450-300/1A) 27 33 kV NCT For 220/33kV T/F (2000-1000/5A) 28 220 kV CVT For Line 29 220kV C&R Panels with SASCkt breaker control Panel with auto reclose & line Protection Panel 30 Ckt breaker control Panel without auto reclose and Transformer protection panel (for both HV & LV side of 220/33kV T/F)(each T/F have 2 no. 33kV Incomer) (1 No. for each T/F) 31 Ckt breaker control Panel without auto reclose and Bus Coupler cum Bus Bar Protection panel (Double Bus bar ) 32 Time synchronizationequipment 33 1 X 21.744 MVAR 33 kV rating Capacitor Bank along with Str. & allied equipments ( NCTs Series Reactor etc.) as perspecification 34 33 kV Line and Earth switch for Cap Bank (630 Amp.) 35 220V 200 AH Tubular Type Lead Acid San Container Battery 36 220 V 200 AH SMPS Battery charger 37 220 V D.C.D.B. 38 415 V LT AC Distribution Board 500 A 39 33/0.4 kV Station T/F 200 KVA 40 100 KVA DG Set along with associated accessories 41 EOT-Crane as per clause 3.10.7 Section-1 and Clause 29.0 of GIS Specification and as per EOT crane specification.(10T) 42 1.1 kV Copper Control Cable Armoured (FRLS type) for 220 kV bays of sizes 7CX4mm2, 2CX4mm2, 4CX4mm2, 2CX6mm2, 16CX2.5mm2, 10CX2.5mm2, 7CX2.5mm2, 3CX2.5mm2 etc. including junction box (as per HVPNL Tech spec.). 43 1.1 kV Copper Control Cable Armoured (FRLS type) for 33kV side of sizes 7CX4mm2, 2CX4mm2, 4CX4mm2, 2CX6mm2, 16CX2.5mm2, 10CX2.5mm2, 7CX2.5mm2, 3CX2.5mm2 etc. including junction box (as per HVPNL Tech spec.). 44 650/1100 Volts 3.5 core 240 mm2 aluminum power cable from Aux. T/F to ACDB 45 650/1100 Volt 3.5 core 70 mm2 aluminum cable for oil filtration set. 46 650/1100 Volt 4 core 16 mm2 armoured copper power cable for MLDB etc and other cable required as per contract. 47 Grounding system of the substation. Earthing Mat Material. The earth mat will be designed / quoted for soil resistivity of 50m. In case soil resistivity is more than 50m then the earth mat will be designed for actual soil resistivity. The payment of extra material to be used for earth mat shall be made on pro rata basis. The approximate area of earth mat to be laid is given in the corresponding columns of the substations. However, item will remain a Lot item.(9300 sq meter (approx) . Note:- Earthing of sub-station and equipments should be in line with HVPNL Tech. spec. and IEEE-80 considering fault and shock duration of 1 sec. 48 Fire Fighting equipments as per section-6:22.5 Kg Capacity FE CO2 type, Trolley Mounted 49 25 Kg Capacity FE DCP type, Trolley Mounted 50 DCP 9 Kg Capacity, Wall mounted 51 FE CO2 6.5 Kg Capacity, Wall mounted 52 DCP 6 Kg Capacity, Wall mounted 53 Foam Type 9 Litre Capacity, Wall mounted 54 Water CO2 9 Litre, Wall mounted 55 Fire Buckets(12 No.s with stand in one set) 56 Supply and installation of 2 fittings of 240W LED lamps with all accessories for Complete lighting of outdoor Switch yard area including all accessories, cables etc. as per clause 16.0 of section 7 of the specifications. 57 Complete lighting of road and street by providing 90W LED lamps on tubular steel poles at a distance of 15meter along the roads and streets including all accessories, cables etc. as per clause 16.0 of section 7 of the specification 58 (A) Supply and installation of 35W LED tube fitting on tubular steel poles along Fencing/ boundary wall at a distance of 30 meter including all accessories, cables etc. as per clause 16.0 of section 7 of the specification. 59 (B)Supply and installation of post top lantern 40W LED Lamps with all complete accessories at the entrance gate of sub-station. 60 Supply and installation of 40W LED Lamps with all complete accessories on corners of control room building. 61 High wall type split AC unit of 2 Ton capacity for computer room (2 no.) and C&R Panel room (4 no.) (as per technical specification) 62 Complete substation automation system for 220/33 kV substations including hardware (along with transducers)& software for present Bays and software for future bay along with associated equipment for the bays as defined in the technical specification, section sub-station automation system) as per technical specification. The scope for present and future is as under:- 220kV System: Present Bays: Line bays=4 T/F bays =2 Bus coupler =1 Future Bays Line bays=2 T/F bays =1 Bus coupler =033kV System: Present Bays: Line bays=16 T/F I/C bays =4 Bus Sectionliser bay =2 Capacitor bay =2 & Station T/F bay=2 Future Bays Line bays=8 T/FI/Cbays =2 Bus Sectionliser bay =1 Capacitor bay =1 & Station T/F bay=0 63 Computer system (SFF) with:Intel Core i5 processor with 11th generation or higher, 1x16GB DDR-IV RAM 2933 MHz or higher expandable upto 64 GB, 1 TB SSD or higher, 19.5” or higher TFT LCD Display (Backlit LED), Preloaded OS: Windows 11 Professional64-bit OEM or higher, with UPS (600VA offline UPS system 1x7AHx12V, MS-Office 2021 standard perpetual licensees or higher, etc. 64 Mono chrome Multi-functional Printer, A-4, 25 PPM, Copy & Scan function, Networking & Wi-Fi both, atleast 1 input tray 65 BOM FOR SAMAST COMPLIANT IEM ( ON SEPARATE CUBICLE) FOR 33 KV I/Ci. 3P4W Interface Energy Meters (ABT type) 0.2s Class 1A with TTB & BCS (02 no. for each 33 KV Incomer) 66 Testing of IEM System from NABL accredited lab 67 Wired Indoor Meters Panel suitable for 8 meters 68 16 P Industrial Grade un-managed Network switch 69 Data concentrator unit (DCU)/ communication Gateway (IG) with dual SIM Modem along with enclosure and accessories 70 Cat-6 cable-unshielded 71 PVC conduit Pipe - 3/4 with accessories for Cat-6 cable lot Lot (In line with cat-6 cable) 72 Armored Fibre Optic Cable (2 pair) 73 HDPE conduit - 40/33 with accessories (In line with armored cable for CT/PT) 74 4Cx4 Sqmm armored and 3Cx2.5 Sqmm, armoured (FRLS) copper control cables (as per note given below)Note- 4Cx4 Sqmm armored and 3Cx2.5 Sqmm armoured (FRLS) copper control cables shall be used for integration of IEMs. The provision of providing the same is to be covered in respective entry of cables of the BoQ. 75 Bolted type 220 kV single suspension string assembly with Silicone Rubber Polymer Composite Insulators (E&M strength 90kN) per string with hardware accessories including ball & socket connection and suspension clamp set suitable for single Tarantula (string). 76 Bolted type 220 kV single suspension string assembly with Silicone Rubber Polymer Composite Insulators (E&M strength 90KN) per string with hardware accessories including ball & socket connection and suspension clamp set suitable for Twin Tarantula (string). 77 Bolted type 33 kV single tension string assembly with Silicone Rubber Polymer Composite Insulators (E&M strength 90KN) per string with hardware accessories including ball & socket connection and tension clamp set suitable for twin Tarantula (string). 78 Bolted type 33 kV single suspension string assembly with Silicone Rubber Polymer Composite Insulators (E&M strength 90KN) per string with hardware accessories including ball & socket connection and suspension clamp set suitable for twin Tarantula (string). 79 C- Wedge connectors matching with conductor size. 80 Copper lugs glands, PVC ferrules for control cabling. 81 Fiber cleats, Aluminium clamps, bolts, nuts, washers etc for fixing control cables in trenches 82 Galvanized iron perforated tray with side coupler plate bolts, nuts, washers and clamps etc. of size 75x25x2 mm, 150X25X2mm, 100X25X2mm etc. & G.I. Conduits of 50mm/100mm dia from equipment to main trench as per Section-7, Switchyard erection. 83 AAC Tarantula Conductor(approx) 84 Spacers for Twin Tarantula conductor 85 7/3.15 Earthwire 86 U-bolt 20mm dia 87 Item for associated structure work‘Lattice type steel structure for 220kV GIS S/Stn.Sector-75A, Gurgaon. Supply of material, preparation of fabrication drawing, galvanizing and delivery of lattice type steel structure for tower and beams for 220/33kV switchyard fabricated from steel conforming to IS:2062 including nuts-bolts gusset plates foundation bolts and other accessories as per drawings supplied by the owner.Main S/Stn. Tower and beamTower type AT-1 88 Tower type AB-1 89 Tower type CT-4 90 Tower type CT-5 91 Beam type DD-1 92 Equipment Supporting Structure) 220 kV NCT drg. No. HTD/ST-150 93 220 kV CVT drg. No. HTD/ST-147 94 220 kV surge arrestor drg.No.HTD/ST-93R 95 33 kV NCT Drg. No. HTD/ST-88 96 33KV L&E switch HTD/ST-110 97 33 kV Surge Arrestor Drg. No. HTD/ST-89R 98 220kV Cable Support Structure for 220kV XLPE Cable(To be designed by the bidder) 99 33kV Cable Support Structure for 33kV XLPE Cable(Drg. No. HTD/ST-89R to be used for Cable Support Structure drawing) 100 220kV D/C line from Sohna Road to 220KV GIS sector-75A, Gurugram :PLC terminals (No.) 101 PLC terminal with Prot.coupler (No.) 102 Wave trap 1250A 103 LTU (P/P) (Set.) 104 48V Lead Acid Tubular San container Battery& SMPS Battery Charger (300AH) 105 HFcable (kms) 106 220kV D/C Panchgaon (PGCIL) to 220KV GIS sector-75A, Gurugram:PLC terminals (No.) 107 PLC terminal with Prot.coupler (No.) 108 Wave trap 1250A 109 LTU (P/P) (Set.) 110 HFcable (kms) 111 Equipments for maintenancePortable circuit breaker operation analyzer. 112 Digital Micro-Ohm meter for contact resistance measurement Ranges (0-100 ohm)(0-1 milliohm)(0-10 milliohm). 113 Dew Point meter 114 Portable partial discharge monitoring system for GIS. 115 Digital Earth resistance meter. 116 5 kV Automated insulation resistance tester. 117 Earth stick with lead suitable for use in 220/33kV Switchyard 118 SF-6 Gas filling and evacuating plant 119 SF-6 Gas leak detector (Portable) 120 Tools for gas handling 121 LT DC Leakage detector from control cabinets and LT cables 122 Mandatory Spares for 220KV GISGeneralComplete GIS modules, along with enclosure, all active parts such as conductor, conductor joints, shields, end covers etc. for each type of➢ Bus Bar Sections (including Bus Bar Interconnection Modules)➢ Bus Ducts Sections (including Compensators/expansion joints/bellows)➢ Bends➢ SF6/Air Bushing.➢ Oil/SF6 Bushing➢ Cable Termination kit 123 SF6 gas Pressure Relief Device assembly of each type 124 SF6 Pressure gauge cum switch /Density monitors and pressure switch as applicable, of each type 125 Coupling device for pressure gauge cum switch for connecting Gas handling plant of each type 126 Rubber Gaskets, “O” Rings and Seals for SF6 gas for GIS enclosures of each type 127 Molecular filter for SF6 gas with filter bags (10 % of total weight) 128 Control Valves for SF6 gas of each type 129 SF6 gas (20 % of total gas quantity) 130 Pipe length (Copper or Steel as applicable) for SF6 Circuit of each type (if applicable) 131 Locking device to keep the Dis-connectors (Isolators) and Earthing/Fast Earthing switches in close or open position in case of removal of the driving Mechanism 132 UHF PD Sensors of each type along with BNC Connector 133 Support Insulators (gas through) of each type (complete with metal ring etc.) 134 Gas Barriers of each type (complete with metal ring etc.) 135 SF6 to air bushing of each type complete in all respect 136 SF6 CIRCUIT BREAKERComplete Circuit Breaker (Three Phase) with interrupter, main circuit, enclosure and Marshalling Box with operating mechanism to enable one to one replacement of applicable type of CB by spare. (if applicable) 137 Fixed, moving and arcing contacts including insulating nozzles of each type (for Main Chamber & PIR Chamber as applicable) 138 Trip coil assembly with resistor as applicable 139 Closing coil assembly with resistor as applicable 140 Relays, Power contactors, push buttons, timers & MCBs etc. of each type 141 Auxiliary switch assembly of each type 142 Operation Counter 143 Wind scope / Observing window of each type 144 For Hydraulic Operated Mechanism, if applicableHydraulic operating mechanism with drive motor of each type 145 Ferrules, joints and couplings of each type 146 Hydraulic filter of each type 147 Hose pipe of each type 148 N2 Accumulator of each type 149 Valves of each type 150 Pipe length (copper & steel) of each size & type 151 Pressure switches of each type 152 Pressure gauge with coupling device of each type 153 Hydraulic oil (20% of total Oil quantity) 154 Pressure Relief Device of each type 155 For Spring Operated Mechanism, if applicableComplete Spring Operating Mechanism including charging mechanism etc. of each type 156 Spring Charging Motor 157 For Hydraulic-Spring Operated Mechanism, if applicableComplete Hydraulic-Spring Operating Mechanism including charging mechanism etc. of each type 158 Spring Charging Motor 159 Pressure switches of each type 160 Pressure gauge with coupling device of each type 161 Disconnector Switches/Earthing SwitchesComplete set of 3-phase dis-connector of each type including main circuit, enclosure, driving mechanism and support Insulator etc. to enable complete one to one replacement of all applicable type of Isolator by spare 162 Complete set of 3-phase Maintenance Earthing switch of each type, including main circuit, enclosure, driving mechanism and support Insulator etc. to enable complete one to one replacement of all applicable type of Earth Switch by spare 163 Complete set of 3-phase Fast Earthing switch of each type, including main circuit, enclosure, driving mechanism and support Insulator etc. to enable complete one to one replacement of all applicable type of Earth Switch by spare (if applicable) 164 Copper contact fingers & corona shield for dis-connector male & female contact–for one complete (3-phase) dis-connector of each type 165 Copper contact fingers & corona shield for Maintenance Earthing switch male & female contacts, for one complete (3- phase) earthing switch of each type 166 Copper contact fingers & corona shield for Fast Earthing switch male & female contacts, for one complete (3-phase) earthing switch of each type (if applicable) 167 Open/Close contactor assembly, timers, key interlock, interlocking coils, relays, push buttons, indicating lamps, Power contactors, resistors, fuses, MCBs & drive controlcards etc. one of each type for one complete MOM boxFor Disconnector 168 For Maintenance Earth switch 169 For Fast Earthing Switch (if applicable) 170 Limit switches and Aux. Switches for one complete MOM BoxFor Disconnector 171 For Maintenance earth switch 172 For Fast Earthing Switch (if applicable) 173 Drive Mechanism of each typei. For Disconnector 174 ii. For Maintenance earth switch 175 iii. For Fast Earthing Switch (if applicable) 176 Motor for Drive Mechanism of each typei. For Disconnector 177 ii. For Maintenance earth switch 178 iii. For Fast Earthing Switch (if applicable) 179 CURRENT TRANSFORMERComplete CT of each type and rating as supplied with enclosure and primary conductors to enable one to one replacement of all applicable type/rating of CT by spare 180 Voltage TransformerComplete PT of each type with enclosure to enable one to one replacement of all applicable type/rating of VT by spare (if applicable) 181 SURGE ARRESTORComplete Gas insulated Surge arrester of each type and ratings with enclosure and insulator (if applicable) 182 Surge counter/ monitor of each type (if applicable) 183 Local Control Cubicle (LCC)Aux. relays, Contactors, Push Buttons, Switches, Lamps, Annunciation Windows, MCB, Fuses, Timers, Terminal Blocks etc. of each type & rating 184 MANDATORY SPARES (33kV GIS)Line voltage transformer (3 nos.) 185 Bus voltage transformer (3 nos.) 186 Current transformers suitable for incomer panel (3 nos.) 187 Current transformers suitable for transformer panel (3 nos.) 188 Current transformers suitable for bus coupler panel (3 nos.) 189 Trip Coil 190 Closing Coil 191 CB Spring charging motor 192 Auxiliary switch (2 no. each type) 193 Disconnector motor for isolator 194 Disconnector motor for earth switch 195 Gas density switch 196 Bursting disc / pressure relief plate complete 197 Capacitive voltage indicator (6 nos.) 198 Civil portionEARTH WORK IN FILLING: Earth filling with good earth (as per satisfaction of Executive Engineer/Civil Works Division), laying in layers (as per specification), dressing, including carriage, irrespective of lead, loading, unloading, watering and compaction in layers with roller including compensation of earth complete in all respect. 199 FOUNDATIONS :Design engineering, supply of labour,T&P,material and construction of RCC footings & pedestals etc. for steel gantry and equipment structures complete in all respects as per technical specifications including cost of excavation,concreting,cement,reinforcement steel,form work,grouting,holding down bolts,back filling etc. and other items not mentioned herein but required for the completion of work.GANTRY TOWERS AT-1 200 CT-4 201 CT-5 202 EQUIPMENT 220kV side220kV LA 203 220kV CVT 204 220kV NCT 205 33 kV side33kV LA 206 33kV NCT 207 CABLE SUPPORT STRUCTURE Design, Engineering, Supply of labour, material and Construction of cable support structure foundations including all associated works, RCC, PCC, reinforcement steel, misc. structural steel and other items not mentioned herein but required for the completion of work as per technical specifications. 220 KV Cable Support Structure 208 33kV Cable Support Structure 209 ROADSSupply of labour, material and construction of cement concrete roads and walkways/shoulders from NH/SH/etc. to Switch yard/Switch house building as per GELO/CLO as per sectional detail drawing no. HCD/SK-181 R1 and technical specification.6.0m wide road (Near main gate of substation) 210 5.0m wide road within substation 211 3.66m wide road within substation 212 CAPACITOR BANK FOUNDATIONSDesign, Engg. & supply of labour, material & construction of foundations for capacitor bank with capacitor unit (with allied equipments) & series Reactor etc. including chain link fencing 1.8M height around cap. bank complete in all respect including any other items not specifically mentioned herein but required for completion of job as per technical specification.1x21.744MVAR 33kV capacitor bank 213 ROAD CULVERTDesign, Engineering and const. of Pipe culvert(s) at suitable locations under the approach road (from main PWD/ HUDA/Municipal/Village road to the sub-station entry point) including, cost of labour, material complete in all respects as per I.R.C. Standards. 214 TRANSFORMER FOUNDATIONDesign engineering, supply of labour, material and construction of foundations including T/F radiator foundations etc. complete in all respect including all associated works, RCC, PCC, Reinforcement steel, misc. structural steel and other items not mentioned here in but required for the completion of work as per technical specifications. In case additional foundation is/ are required as per approved equipment drawing, the same shall be constructed by the successful bidder without any extra cost toHVPNL.Such drawing(s)shall, however, be got approved from HVPNL.100MVA,220/33kV T/F foundationincluding associated foundations for radiator, NIFPES, fire fighting system etc. complete in all respect. 215 200KVA 33/0.4kv Station T/F 216 100kVA DG Set 217 OUTDOOR CABLE TRENCHESSupply of labour, material such as cement, reinforcement steel, GI angles, flats, PCC & brick pillars below cable trenches for construction of Out-Door Cable Trenches (ODCT) of required depth/ type with pre-cast RCC covers including associated works like Cable Trench Culverts crossings for roads and sumpit-cum-pump chamber with 2HP motor of reputed make, starter, volt meter, amp-meter etc. as per approved Trench layout plan, HVPNL drgs. & tech. specs. complete in all respect.D-type Trench 218 E-type Trench 219 F-type Trench 220 G-type Trench 221 H-type Trench 222 Road Culvert 223 Sump pit cum pump chamber 224 SITE SURFACINGProviding, supplying & laying 100mm thick in two layers of 50mm each of 20mm nominal size uncrushed/crushed/ broken stone pebbles gravel fill including dressing, rolling & compacting complete in all respects as per specs. & instructions of engineer incharge. 225 Providing, supplying & laying 100mm thick PCC (1:4:8) using 20mm nominal coarse aggregates and supplying & spreading 100mm thick layer of 40mm nominal size uncrushed/ crushed/broken stone pebbles over the PCC including construction of toe wall (exposed wall plastered with cement mortar 1:5) to hold 40mm single size uncrushed/ crushed /broken stone pebbles wherever required in the bays covered under the present scope as detailed in the GELO & instructions of engineer incharge. 226 RCC retaining wallSupply of labour, material and construction ofRCC retaining wall below DPC to retain the earth filling complete in all respect. Further, if L-shape retaining wall is required to be constructed as per site, the successful bidder shall develop the designs & drawings as per the soil investigation report attached in specification and shall get these checked/vetted from any professsional institute as per contract before final approval. Nothing extra shall be paid on this account. i. Difference between NGL & FGL from 2.5 to 3.5 mtr. 227 ii. Difference between NGL & FGL from 3.5 to 4.0 mtr. 228 Design engineering, supply of labour,material and construction of RCC T/L shaped retaining wall below DPC to retain the earthfilling complete in all respect and design /drawing shall be got checked/ vetted from any professsional institute as per contract before final approvalNothing extra shall be paid on this account. Iii. Difference between NGL & FGL above 4.0 mtr. 229 BOUNDARY WALL;Supply of labour, T&P, material & construction of front, side & U/C boundarybelow DPC level as per GELO/CLO, tech. spec. & HVPNL drgs including excavation, PCC, brickwork, back filling, plaster, painting etc. complete in all respects. 230 Supply of labour, material and construction of front, C & U/C boundary walls above DPC including main gate foundationsas per GELO/CLO, technical specifications. & HVPNL drg. HCD/TS-1176 R3 including DPC complete in all respect..6 ft. high U/C B/wall with barbed wire on angles at top. 231 4½ ft. high front wall including providing grill at top of wall & construction of gate pillars. 232 4½ ft. high side wall with barbed wire on angles at top of wall. 233 MULTISTOREY 33kV GIS CUM CONTROL ROOM BUILDINGDesign including architectural and structural design/drawings, Engineering, supply of labour,T&P and material etc.for construction of multi storey GIS Hall comparising of ground and1st floor (to accumulate 33kV GIS & Control Room Building) including exterior weather proof paint, interior emulsion, all internal services like water supply and providing of 5000ltr. Capacity double layer Sintex/ Diplast PVCtank,Sewerage System, electrification including wiring, receptacle, modular switches, lighting, maximum 20W 4ft. long LED tube swith fittings minimum 1960 lumens, bulk headlig hts including fixtures. ceiling/ exhaust fans, plinth protection, closed drain (RCC Pipe)around building, Indoor trenches and provision for mechanical operated crane system adjacent to building, Soakage pit ,connection of sewerage system to Soakage pit/ sewerage system of local authority (as applicable), connection to main water supply system of local authority, bore (asapplicable)etc. and any other item not mentioned here in but required for completion of job as per specifications. Minimum size of the buildings has been provided in the GELO.Since the detailed engineering is in the scope of the successful bidder, no claim for increase in size of the building shall be admitted.The GIS Hall should be equipped with fire detection system and shall be done by the succesfull bidder without any extra cost to employer.The building should be design to ensure early warning and prompt response in case offire.The system must include advance smoke detection system, advance heat detection system, audible and visual alarms alongwith alarm panels, fire extinguishers, fire buckets, warning signs, exitplans, etc complete in all order torun the system efficiently, wherever required as per latest IS Codal provision and in consultation with engineer incharge. 234 U/C FENCING & GATES Providing & fixing chain link fencing including foundations, GI angle iron posts and gate(s) complete as per electrical layout & tech. spec. & as per drawing attached. 235 PCC PAVEMENTConstruction of PCC pavement in front, rear or side (as per site requirement of the switch house building) as per drawing no. HCD/SK-172 & technical specifications. 236 GIS Hall / BuildingDesign,Engineering including architectural & structural, supply of labour, material and construction of GIS building with ventilation system including crane hoisting system (EOT), equipment foundations as detailed in the bill of quantities under Annexure-1 of Section of bid/ contract documents , electrification including wiring, receptacle, modular switches, maximum 20W 4ft. long LED tubes with fittings minimum 1960 lumens, bulk head LED lights including fixtures, ceiling/ exhaust fans, stair case etc.interior & exterior acrylic emulsion, paint, RCC paving /plinth protection starting from the building upto1.5 m clear distance for the full length width of the building, closed drain around the building (i.e RCC Pipe)etc. complete in al lrespect for GI Shall / building and any other item not mentioned here in but required for completion of job as per specifications. The building should be equipped with fire detection system and shall be done by the succesfull bidder without any extra cost to employer.The building should be design to ensure early warning and prompt response in case offire. The system must include advance smoke detection system, advance heat detection system, audible and visual alarms alongwith alarm panels, fire extinguishers, fire buckets, warning signs, exit plans, etc complete in all order to run the system efficiently , wherever required as per latest IS Codal provision and in consultation with engineer incharge.220kV GIS Hall 237 DRAINAGE-CUM-RAIN HARVESTING SYSTEMSupply of labour, material for construction ofrecharge structures with bore well(s) as per HVPN drawings & specs. complete in all respect. The location of recharge structures shall preferably be located on corner(s) of the substation and shall be got decided from the concerned Engineer in-Charge on the basis of surroundings of the substation(s). In case ground water table is less than 8m from FGL, rain harvesting well shall not be constructed (the drainage system with sump pit is to be constructed as per item mentioned below). 238 The successful bidder shall evolve design & drawing for drains, manholes with RCC covers andsettlement tankincluding preparation of drainage layout drawing for disposal of rain water from building’s roof top & switch yard (s/stn.) area into respective bore well(s) in such a way that there shall be no ponding of water on the roof and switch yard (s/stn.). The layout so developed shall be got approved from the employer. The location of sump-pit-cum-pump chamber shall preferably be locatedon corner(s) of the s/stn. and shall be got decided from the concerned Engineer in-Charge on the basis of surroundings of the substation(s). The successful bidder will also supply labour and material for construction of sump-pit-cum-pump chamber as per HVPNL drgs. & provide one no. non clog pump(s) of 5HP of reputed make capacity with main switch, starter, volt meter, Amp. Mtr. etc. (for each sump pit) for disposal of excess water to outfall point. Any other item(s) not mentioned herein but is/are required for completion of works shall be done by the successful bidder without any extra cost to the employer.Drain Section-1 239 Drain Section-2 240 Drain Section-3 241 Road Crossing 242 Trench Crossing 243 Sump Pit Cum Pump Chamber 244 REMOVAL OF MALBARemoval/Disposal of malba irrespective of lead including loading & unloading etc. complete in all respect. Malba shall be disposed of to a suitable undisputed place outside the substation. as per Govt. norms. The successful bidder shall be responsible in case some dispute arise on account of disposal of malba/sludge at a disputed site. 245 CONSTRUCTION OF ANTI FIRE WALLConstruction of RCC anti fire wall of suitable height between T/F as per HVPNL drawing and all associated works including supply of labour, material, cement, reinforcement steel, steel form work etc. as per technical specification. 246 RCCM-20 inclusive of labour, material, shuttering, steel reinforcement etc. complete in all respects to compensate excess quantity required to be executed due to difference in existing ground level and the formation level to be fixed after contouring or difference on account of revised drawing issued at the time of construction and the tender drawing.
Contract Date : Ref. Documents   |   Contract Value : Ref. Documents
BRR : 9239864 Tender For Augmentation of 400 kV substation Dhanonda, Nawada and Kirori-- 1 500 MVA,400/220/33kV, 3 Phase Auto Transformer excluding insulating oil 2 Insulating oil for 500 MVA,400/220/33kV, 3 Phase Auto Transformer (including 10% extra oil) 3 Digital RTCC Panel consist of digital RTCC relays 4 BDV testing Kit 5 Tool Kit 6 420kV circuit breakers (3 Ph.) with support structures 3150 A, 63 KA without closing resistor 7 420kv (6core) CT (1 Ph.)- for main bay & tie bayRatio- 3000-2000-500/1-1-1-1-1-1A, 63 KA 8 420kV Isolators (double break type)i) 3150A, 63 KA, isolator with one E/S 9 ii) 3150 A, 63 kA, isolator with both side E/S 10 336 kV Surge Arrester (Gapless), 63 KA 11 420kV Bus Post Insulator 12 400 KV C&R Panels (Simplex type)- SAS CompliantCircuit Breaker control panel without Auto Reclose and transformer Protection Panel (For HV side) with peripheral relay for bus bar protection on 400kV side. 13 Circuit breaker control panel with Auto Reclose and Tie protection panel with P.U. of future line bay 14 i) Extension of existing Fire Protection System (As per technical specification) for 500 MVA Auto-Transformer at 400kV sub-station as per site requirement is in the scope of bidder. 15 245 kV Circuit Breakers(3 ph)i) 2500 A, 50 kA 16 245 kV T/F I/C CT (1 ph) 50 kA with(I/C T/F CT ) (Ratio 1600-800/1-1-1-1-1A) 17 245 kV Isolator (3 ph) Double break2500A,50 kA,Isolator 18 220 kV Surge arrestors216kV, 50KA 19 245kV Bus Post Insulator 20 220 kV C&R Panels -SAS CompliantCircuit Breaker control panel without Auto Reclose for T/F I/C for 500MVA, 400/220kV T/F with peripheral relay for bus bar protection on 220kV side 21 220 kV C&R Panels -SAS CompliantCircuit Breaker control panel without Auto Reclose and transformer protection incomer panel (for LV side) with peripheral relay for bus bar protection on 220kV side 22 Supply and installation of 2 fittings of 240W LED lamps with all accessories for Complete lighting of outdoor Switch yard area including all accessories, cables etc. as per HVPNL Technical specification . 23 Power cables (XLPE & PVC) as per site requirements. 24 Complete substation automation system for 400/220 kV substations including hardware (along with transducers) & software, if required for present scope of work ( 1 no.500 MVA 400/220/33 kV T/F Bay(Refer Note 2 also) 25 Armoured copper control cables (PVC) of various sizes e.g. 7Cx4mm2, 4Cx4mm2, 2Cx4mm2, 2Cx6mm2, 3Cx2.5mm2, 7Cx2.5mm2, 10Cx2.5mm2 & 16Cx2.5mm2 and as specified in relevant technical specifications, with juction box for 400 kV & 220 kV side with associated accessories like clamps, PVC ferrules, glands, lugs, fibre cleat/aluminium clamp/bolt/washers etc. as per specification. 26 Dismantlement & re-erection of 220kV line Bay along with all material including equipments and support structures from A-8 to A-7 at 400KV Substation Kirori complete in all respect with disconnection of the existing cable & rewiring after erection, testing & commissioning with SCADA integration, PLCC wiring etc.a) 220 kV Circuit Breaker 27 b) 220 kV Current Transformer 28 c) Isolators 29 d) Isolators with Earth Switch 30 e) 220 kV CVT 31 f) 220 kV LA 32 g) 220 kV PI 33 h) 220 kV C&R Panel 34 i) 220 kV Wave Trap 35 j) 220 kV MK 36 k) All the above equipments alongwith associated support structures, jumpers, hardware fittings, conductor etc. as per site 37 Bolted type 400 kV Double tension string assembly with Silicon rubber Polymer Composite Insulators (E&M strength 120 KN) with all hardware accessories including ball & socket connection accessories for Twin Tarantulaconductor (string). 38 Bolted type 400 kV single suspension string assembly with Silicon rubber Polymer Composite Insulators (E&M strength 120 KN) with all hardware accessories including ball & socket connection accessories for Twin Tarantulaconductor (string). 39 Bolted type 220 kV single suspension string assembly with Silicon rubber Polymer Composite Insulators (E&M strength 90 KN) with all hardware accessories including ball & socket connection suitable for Twin Tarantula (string). 40 Bolted type 220 kV Single tension string assembly with Silicon Rubber Polymer Composite Insulators (E&M strength 90 KN) with all hardware accessories including ball & socket connections and tension clamp sets suitable for Twin Tarantula (string). 41 Earthing material – 40mm MS rod & G.I. earthing flat for connecting all the equipments with existing main earthmat, risers & independent earthing of T/F up to water level.Suitable arrangements as per actual site conditions shall be made to take care of 63kA fault level as per technical specification and IEEE-80. 42 Galvanized iron perforated tray with side coupler plate bolts, nuts, washers and clamps etc. of size 150x25x2 mm, 100x25x2 mm and 75x25x2 mm and G.I conduits of 50/100mm diameter from equipment to main trench as per technical requirement. 43 Clamps & connectors including equipment connectors, cable supporting angles/channels, cables, C-Wedge connectors, spacers, lug glands, firefighting equipment ,Junction box,Pipes for equipments and lighting, lighting PVC ferrules all accessories etc. as per GELO and specification. 44 4.5 IPS AI tube alongnwith all accessories e.g. welding sleeves, corona cap, terminal connector for BPI, inter connector, BPI etc. (all as per site requirement) 45 Tarantula Conductor 46 GS Earth wire (7/3.66) as per specification 47 U-bolt 20mm dia 48 Bay marshalling Kiosk with mounting structure for 400kV side (Front side with 350 tb for control circuit and rear side power circuit) 49 Bay marshalling Kiosk with mounting structure for 220kV side (Front side with 300 tb for control circuit and rear side power circuit) 50 Item for associated Structure work‘Lattice Type Steel Structure. Supply of material, preparation of fabrication drawing, galvanizing and delivery of lattice type steel structure for tower and beams for 400/220kV switchyard fabricated from steel conforming to IS:2062 including nuts-bolts gusset plates foundation bolts and other accessories as per drawings supplied by the owner.* For 220 kV Lattice Structure (Standard) mentionedbelow Although the equipment structures are standardized as mentioned below, however, in case specific requirement of fitment of structures is not met with these standardized 220KV structures in that case the Design & Engineering of the equipment structures for 220KV equipments (lattice type / pipe type, as applicable) shall be in in the scope of the successful bidder. Further, the Design & Engineering cost of these support structures shall also deemed to be included in the supply cost of these equipment structures.Main substation Tower and beamTower type AT-1 51 Tower type AT-3 52 Beam Type AB-1 53 400 kV Pipe Structures (Standard)CT (Drg. No. HTD/ST-197) 54 Isolators ( Drg. No. HTD/ST-196) 55 Surge Arrestor (Drg. No. HTD/ST-195) 56 BPI(Drg. No. HTD/ST-193) 57 220 kV Lattice Structure (Standard)CT (Drg. No. HTD/ST-147) 58 Isolators (Drg. No. HTD/ST-170) 59 BPI (Drg. No. HTD/ST-116 R3) 60 Surge Arrestor( Drg. No. HTD/ST-93 R) 61 LIST OF MANDATORY SPARES FOR 400kV DHANONDA, 400kV NAWADA and 400kV KIRORI420 kV SF-6 circuit Breakeri.One pole complete without closing resistor, grading capacitor (if applicable) complete with column and interrupter with MB & operating mechanism and without support structure 62 ii.SF-6 Gas (40% of ordered quantity) 63 iii.Trip coil with resistor 64 iv.Closing coil with resistor 65 v.Terminal pad and connectors 66 vi.Molecular filter for SF6 Ckt for 1 pole of CB 67 vii.Density /pressure monitor for SF-6CKt for 1 pole of ckt breaker 68 viii.Corona rings of each type 69 ix.Fixed moving and arching contacts including insulating nozzels for one pole of CB 70 x. Relays, power contractors, switch fuse units, limit switches, push buttons, timers and MCBs etc. (1 no of each type) 71 xi. Closing Coil assembly 72 xii. Trip Coil assembly 73 xiii. Set of control valves (of each type) 74 xiv. Pressure switches of each type ( 1 CB) 75 xv. Pressure Gauge with coupling device of each type 76 xvi. Aux contact assembly 77 xvii. Operation counter 78 xviii. All type of coupling for SF6 gas 79 xix. Rubber Gasket “O Ring” and seal (complete replacement for 1 phase of 420kV SF6 Circuit Breaker 80 Spring Operating Mechanism (if applicable)i. Complete Spring Operating Mechanism 81 ii. Closing Dashpot 82 iii. Opening Dashpot 83 iv. Opening Catch Gear 84 v. Closing Catch Gear 85 420 kV Double Break Isolatori. One complete pole with support insulators excluding structure & motor operating mechanism 86 ii. Copper contact fingers for female & male contacts 87 iii. Terminal pad with connectors 88 iv. Relays, power contactors, MCBs switch fuses, push buttons and resistors for electrical control ckt as per approved schematic 89 v. Timers. Key interlock, push button switch, limit switch, aux. switches, corona shield, motor having bearing assembly etc. 90 vi. Support Insulator 91 336 kV Surge Arresteri. 336 kV Surge Arrester complete with Insulating base and terminal connectors 92 ii. Surge Counters/monitors 93 Transformers protection panel sparesi. Transformers differential protection relay including all aux. CTs 94 ii. Restricted earth fault protection relay with non-linear resistor 95 iii. Back up for protection relay with 3 O/C and E/F element 96 iv. Over fluxing relay, if separate relay is provided in the approved C&R panel 97 v. Over load spare relay with timer, if separate relay is provided in the approved C&R panel 98 Substation Automation Systemi. Intelligent electronics device (IED) 99 ii. Set of each type optic fire cables of length of longest section used 100 iii. Set of connectors (one of each type) for optic fibre cables 101 iv. Ethernet switch 102 420 kV CT 103 245kV SF-6 CktBreakeri. One pole complete withof 2500 A CB with pole column and interrupter with MB & operating mechanism, grading capacitor (if required) and without support structure 104 ii. “O” rings, gaskets, Seals for operating mechanism 105 iii. Trip coil with resistor 106 iv. Closing coil with resistor 107 v. Terminal pad and connectors 108 vi. Molecular filter for SF6 Ckt for 1 pole of CB 109 vii. Density /pressure monitor for SF6 ckt for 1 pole of ckt breaker 110 viii.Corona ring of each type 111 ix. Fixed moving and arcing contacts including insulating nozzles for one pole of CB. 112 x. Relays, power contractors , switch fuse units , limit switches , push buttons m, timers and MCBs etc 113 xi. Closing Coil assembly 114 xii. Trip Coil assembly 115 xiii. Set of control Valve (of each type) 116 xiv. Pressure switches with (1 CB) 117 xv. Pressure gauges with coupling device of each type 118 xvi. Aux switch assembly 119 xvii. Operation counter 120 xviii. All type of coupling for SF6 Gas 121 Spring Operating Mechanism (if applicable)xix.Complete Spring Operating Mechanism 122 xx. Closing Dashpot 123 xxi. Opening Dashpot 124 xxii. Opening Catch Gear 125 xxiii. Closing Catch Gear 126 245 kV Double break isolatori. One complete pole of 245 KV 2500A Isolator along with support insulators & operating mechanism. 127 ii. Copper contact fingers for female & male contacts. 128 iii. Terminal pad with connectors 129 iv. Relays, power contactors, switch tests & push buttons 130 v. Motor with gear assembly and bevel gear assembly 131 vi. Hinge pins 132 vii. Corona shield rings 133 viii. Bearing 134 ix. Current Carrying assembly 135 x. Limit switch 136 216 kV Surge Arrester216 KV Surge Arrester Complete with Insulating base and terminal connectors 137 Surge Counters 138 220 kV T/F I/C CT 139 LIST OF MANDATORY SPARES FOR 500 MVA AUTO TRANSFORMER (AS APPLICABLE)Oil cooler pump with motor 140 Buchholz relay complete with float and contacts (main Tank) 141 Local & remote WTI complete with sensing device & contacts 142 Oil temperature indicators with contacts & sensing device 143 Pressure relief device 144 Magnetic oil level gauge 145 Cooler fan with motor 146 Starters, contactors, switches & relays for electrical control panels (one set of each type) 147 Set of valves (complete set for one transformer) 148 Fuses & MCBs ( one set complete for replacement for one transformer) 149 Oil sampling bottles (Stainless Steel, 1 Ltr) 150 Oil storage tank (15 KL) 151 Indicating Lamps (1Set consisting of complete replacement for one transformer). 152 Aux. Transformer for control of cooler control cabinet and OLTC (if applicable) 153 Breather assembly (one of each type ) for conservator and OLTC 154 Remote tap position indicator 155 Oil flow indicator with flow switch 156 Oil surge relay for OLTC 157 420kV Bushing with metal parts, gasket and lifting tools 158 245kV Bushing with metal parts & gasket 159 52kV Bushing with metal parts & gasket (if applicable) 160 Neutral Bushing with metal parts & gasket 161 Cartridge for Online insulating oil drying system. 162 1. FoundationsSupply of labour, T&P, material and construction of RCC footings & pedestals etc. for steel gantry and equipment structures complete in all respects as per technical specifications & drawings attached with the tender document including cost of excavation, concreting, cement, reinforcement steel, form work, grouting, holding down bolts, backfilling etc.and other items not mentioned herein but required for the completion of work. Surplus earth, if any shall be disposed off to a suitable place within the substation as per direction of engineer incharge without any extra cost. For 220kV Lattice Structure foundation*Although the equipment structures are standardized as mentioned at electrical BOQ (Section-1), however, in case specific requirement of fitment of structures is not met with those standardized 220KV structures in that case the Design & Engineering of the equipment structures along with the foundation for 220KV equipments (lattice type / pipe type, as applicable) shall bein the scope of the successful bidder. Also Design Engineering cost of foundationsshalldeemed to be included in the quoted rates.A. Gantry Towersi) AT-1 163 ii) AT-3 164 B. Equipment400 kV sidei) 400kV CT 165 ii) 400kV L&E/Isolator 166 iii) 400kV LA 167 iv) 400kV Post 168 220 Kv Side i) 220 kV LA 169 ii) 220kV CT 170 iii) 220kV Post 171 iv) 220kV L&E/Isolator 172 v) 220kV CVT 173 2. Breaker Foundation Design, engineering, supply of labour, material for construction of breaker foundations including all associated works such as PCC, RCC, structural steel, steel reinforcement, form work etc. or any other items not specifically mentioned herein but required for completion of work as per approved equipment(s) and technical specifications. Surplus earth, if any shall be disposed off to a suitable place within the substation as per direction of engineer incharge without any extra cost.i) 400 kV Circuit Breaker 174 ii) 220kV Circuit Breaker 175 3. Transformer Foundation i) Design, Engg., supply of labour, material and construction of T/F foundation including radiator foundations etc. complete transformer foundations including all associated works, RCC, PCC, Reinforcement steel, misc. structural steel and other items not mentioned herein but required for the completion of work as per technical specifications. In case additional foundation is/are required as per approved equipment drawing, the same shall be constructed by the successful bidder without any extra cost to HVPNL. Such drawing(s) shall, however, be got approved from HVPNL. Surplus earth, if any shall be disposed off to a suitable place within the substation as per direction of engineer incharge without any extra cost.500MVA,400/220/33kV T/F block foundation including radiator foundation and oil pitsystem etc. complete in all respect 176 4. OUTDOOR CABLE TRENCHESSupply of labour, material such as cement, reinforcement steel, GI angles, flats, PCC & brick pillars below cable trenches for construction of Out-Door Cable Trenches (ODCT) of required depth/ type with pre-cast RCC covers including associated works as per approved Trench layout plan, HVPNL drgs. & tech. specs. complete in all respect. Surplus earth, if any shall be disposed off to a suitable place within the substation as per direction of engineer incharge without any extra cost.i) D-Type Trench 177 ii) E-Type Trench 178 iii) F-Type Trench 179 iv) G-Type Trench 180 v) Trench Culvert 181 5. Site Surfacing5.1 PCC WITH GRAVEL (FRESH)Providing, supplying & laying 100mm thick PCC (1:4:8) using 20mm nominal coarse aggregates & spreading 100mm thick layer of 40mm nominal size uncrushed/crushed/broken stone/ pebbles over the PCC including construction of toe wall (exposed wall plastered with cement mortar 1:5) to hold 40mm size uncrushed/crushed/ broken stone/pebbles wherever required in the bays covered under the present scope as detailed in the GELO & instructions of engineer incharge. 182 5.2 ONLY GRAVELProviding, supplying & laying 100mm thick in two layers of 50mm each of 20mm nominal size uncrushed/crushed/ broken stone pebbles gravel fill including dressing, rolling & compacting complete in all respects as per specs. & instructions of engineer incharge. 183 5.3 PCC with existing gravelCollection, screening, cleaning & stacking of existing laid stone ballast (gravel) & laying 100mm thick PCC (1:4:8) using 20mm nominal coarse aggregates & re-laying the collected gravel in 100mm thick layer over the PCC including construction of toe wall (exposed wall plastered with cement mortar 1:5) to hold 40mm size uncrushed/crushed/ broken stone/pebbles wherever required in the bays covered under the present scope as detailed in the GELO & instructions of engineer incharge, only the gravel laid a fresh will be measured and paid. 184 6. RCC Antifire wallDesign Engineering & construction of RCC anti fire wall of suitable height & length between 500 MVA T/F and all associated works including supply of labour, material, cement, reinforcement steel, steel form work etc. as per technical specification. Surplus earth, if any shall be disposed off to a suitable place within the substation as per direction of engineer incharge without any extra cost. 185 7. AC Kiosk (RCC Framed Structure)Design, Engineering (architectural and structural drawings of AC Kiosk room), supply of labour, material and construction of AC Kiosk room on RCC framed structure including Anti-Termite treatment, plinth protection, electrification (Ceiling LED tubes with fitting, modular switches, boxes, AC, electric wire etc.), acrylic emulsion and weather proof (exterior acrylic paint),aluminum work (doors/windows/ventilators frames etc), false ceiling, floor finishing,indoor RCC cable trenches,double brick wall with 50mm thick glass/mineral wool insulation complete in all respect as per technical specification. Items, which are not mentioned but required for completion of work shall be provided by the successful bidder without any extra cost. Surplus earth, if any shall be disposed off to a suitable place within the substation as per direction of engineer incharge without any extra cost.i) 400 kV side 186 ii) 220kV Side 187 Dismantling of existing RCC trenches and Brick drainsDismantling including foundations of following structure. The material whatsoever shall be the property of the successful bidder. The dismantled material shall not be allowed for reuse at any of the sub-stations; however, HVPNL may allow use of bricks for brick ballast purpose only. Further, if rerouting of drain is required in present bays the same shall be is in the scope of successful bidder without any extra cost.8.1 Dismantling of existing RCC trenches and Brick drains
Contract Date : Ref. Documents   |   Contract Value : Ref. Documents
BRR : 9921536 Tender For Material Supply, Spares & Special Tools - RGC - Construction of 33/110kV Step Up GIS at Pushpakandam-- 1 Design, Engineering, Manufacture, Testing at manufacturers works, Delivery at site including all materials, accessories such as OLTC,RTCC, with Transformer Oil and 10% extra Oil, spares,Gaskets, OTI,WTI,MOLG indicators with transducers and Tools as per specification , loading and unloading, transportation, handling, proper storage at siteThree Phase Two Winding Transformer33/110kV, 60MVA Capacity with optical sensors and Remote Data Transfer facility with optical communication media, and all other accessories complete, with SAS Integration Scope , all required valves and flanges for NIFPS shall be provided for transformer at the time of transformer design itself,inclusive of necessary connectors/clamps suitable for Aluminium tube/ACSR conductor(All other items as per technical specification / Layout drawings) - intended for Renewable Energy Evacuation 2 Design, Manufacture, Testing at Manufacturers works, Transportation and Delivery of 110 kV, 3 Phase Encapsulated Double Busbar Indoor Gas Insulated Switchgearequipmentand other accessories at Substation siteand as per respective Technical Specifications, Single Line Diagram, General Arrangement Drawings, IS/IEC standards, approval of KSEBLand relevant special conditions applicable. The quote for each bay shall include necessary interconnecting GI bus ducts within the building. The supply include all accessories of GIS bay, earthing materials for forming the earth grid inside the GIS hallas per standards of GIS earthing (Cu/Al), including RF Earthing, Cable tray, control cable from GIS to LCC, LCC panel, ladder etc. complete. 3 110 kV GIS Feeder Bay with PT(40kA/ 1250A min) 4 110kV GIS Double Bus bar arragement with PT(40kA/ 2500A min) 5 110kV GIS Bus Coupler Bay(40kA/2500A min) 6 110kV GIS Transformer Bay (40kA/1250A min) 7 Polymer housedSurge Arrester suitable for 110kV, 10kA, Class 3 withclamps, terminal connectors suitable for connection of any type of conductor or Al/cu pipe bus as per requirement, leakage current measuring meter with counter, flexible copper cable of required size and all accessories complete 8 110kV composite solid core station post insulator , clamps, connectors etc suitablefor Al/ Cu Pipe Bus /Conductors. 9 Neutral CT (NCT) 36kV 3150Afor 60 MVA 110/33kV, Power Transformer with structure including clamps,terminal connectors and 36kV composite solid core post insulator with structure for support of GI earthing conductor/strip with terminal connector and all other accessories complete-Ratio 1200-600/1-1 Amps(33 kV side) 10 Neutral CT (NCT) 36kV 3150A for 60 MVA 110/33kV, Power Transformer with structure including clamps,terminal connectors and 36kV composite solid core post insulator with structure for support of GI earthing conductor/strip with terminal connector and all other accessories complete-Ratio 400-200/1-1 Amps(110 kV side) 11 UG power cable- 110kV, Single core, 630sqmm, Aluminium conductor,XLPE insulated,Aluminium Corrugated sheathedandHDPE Outer jacket under ground cable having rated short circuit capacity for both conductor and armourwith necessary Non - Magnetic , Metalic Trefoil/flat formation clamps atminimum 3 metre interval, steel/nylon cable ties wherever necessary 12 Outdoor termination kit suitable for 110kV, 630 Sqmm Single core Copper/ Aluminium UG cable for yard structure mountinginclusive of all accessories like earthing cable, suitable Non - Magnetic, Metalic clamp for fixing cable to support structure etc at 1m interval complete. 13 Indoor Plug in Type GIS termination kit for 110kV 630 Sqmm XLPE Single coreCopper/ Aluminium UG cable,inclusive of all accessories like earthing cable, suitable Non - Magnetic , Metalic clamp for fixing cable to support structure etc at 1m interval complete. 14 Supply of 4IPS Schedule 40 Al. Tube including requiredJointing Sleeves, Expansion joints, etc. withnecessary fixing clamp and all accessories complete for 110kV,33kV equipment to equipment connection 15 Three Phase Link Box 6.6kV withoutSVL for 110kV cable with copper bonding cable(minimum cross-section 300sq.mm) including all accessories 16 Three Phase Link Box 6.6kV withSVL for 110kV cable with copper bonding cable(minimum cross-section 300sq.mm) including all accessories 17 33kV Indoor composite VCBPanels having bus capacity 31.5 kA for 3sec, 3150A at STC continuous rating, 4 nos feeder bays having capacity not less than 1250A ,2 nos transformer feeder bays (for 33/110kV transformer) having capacity not less than 2000A ,1 nos transformer feeder bay ( for 33/11 kV5MVA Transformer ) having capacity not less than 1250A and1 nos bus coupler with bussection panel not less than 3150A, two bus PT panel at both side of the bus .Every feeder/incomer/ bus coupler shall have CT, E/S, synchro check, SEM Energy Meter, Ammeter, Voltmeter, Control and Protectionincluding earthing as per standards(Cu), cable tray, control cables etc completeand as per SLDand specifications. 33/110 kV 60 MVA Transformer feeder shall have provision for termination of cable size 3 runs per phase of 630 sqmm Aluminium cable. Each incomer panel (transformer) shall be provided with additional special protection class CT cores for differential protection scheme M1 and M2 at 110kV transformer C&R panel. All the feeders shall be remote controlled from SCMS and from the local console of the numerical relays with Bay Control Unit and protection unit including supply of the same. The supply includes one number VCBfor each ratings as spare (2000A, 1250A) and two numbers of service trolley for VCB , E/S, PT and spares (as per attached list clause 6.6 & 6.7 of volume 2, Chapter 27). 18 Polymer housedSurge Arrester suitable for 33kV, 10kA, Class-3 with clamps, terminal connectors etc. suitable for connection ofany type of conductor or Al /Cu pipe bus as per requirement, including leakage current measuring meter with counter, flexible copper cable of required size and all accessories complete (33kV Feeder/ Transformer) 19 33kV 800A Triple Pole Line Isolator with Structure, clamps, terminal connectors etc. suitable for connection of any type of conductor or Al/Cu pipe bus as per requirement 20 33kV Pin insulator with pin 21 33kV composite solid core station post insulator with high level structure with clamp & connectors suitable for Al pipe/conductor. 22 UG power cable- 33kV 1Cx630sqmm Aluminium 33kV, XLPE Aluminium armoured having rated short circuit current capacity for both conductor and armour and HDPE outer jacket for 33/110kV 60MVA transformer incomer with necessary Non-magnetic, metallic, Trefoil/flat formation clamps at minimum 3 metre interval and steel/nylon cable tie wherever necessary 23 Outdoor Heat shrinkable termination kit suitable for 33kV, 630 Sqmm XLPE Single core Aluminium UG cablewith necessary clamps, connectors suitable for connection ofany type of conductor or Al /Cu pipe buswith all accessoriesincluding cost of bimetallic strip etc. and suitable Non-magnetic, metallic clamps for fixing cable to support structure at 1m interval complete. 24 Indoor Heat shrinkable termination kit suitable for 33kV, 630 Sqmm XLPE Single core AluminiumUG cablewith necessary clamps, connectors suitable for connection ofany type of conductor or Al /Cu pipe buswith all accessoriesincluding cost of bimetallic strip etc. and suitable Non-magnetic, metallic clamps for fixing cable to support structure at 1m interval complete. 25 Design, Engineering, manufacturing, testing at Manufactures worksite, supply, delivery,loading and unloading, transportation, handling, proper storage at site,supervisionof erection, testing and commissioning of 33/11kV, 5MVA three phase two windingtransformer as per technical speciationsincluding all materials, accessories such as Off Load Tap Changer, Transformer Oil and 10% extra Oil, spare Gaskets, OTI,WTI,MOLG indicators with transducers as per specification and Remote Data Transfer facility with optical communication media, with SAS Integration Scope , inclusive of necessary connectors/clamps suitable for Aluminium tube/ACSR conductor(All other items as per technical specification / Layout drawings) - intended for Renewable Energy Evacuation 26 Neutral CT (NCT) for 5 MVA 33/11kV Power Transformer with structure including clamps,terminal connectors andcomposite solid core post insulator with structure for support of GI earthing conductor/strip with terminal connector and all other accessories complete -Ratio 200/1-1 Amps (33kV side) 27 Neutral CT (NCT) for 5 MVA 33/11kV Power Transformer with structure including clamps,terminal connectors andcomposite solid core post insulator with structure for support of GI earthing conductor/strip with terminal connector and all other accessories complete -Ratio 300/1-1 Amps (11kV side) 28 Alumimium UG Cable- 33kV, 3Cx300 sq.mm XLPE insulated, Galvanised steel strips armoured power cable for feeders / Aux Tfr with necessarymetallic, non magnetic clamps atminimum 3 metre interval, steel/nylon cable tie wherever necessary 29 Outdoor Termination kit Heat Shrinkable Type for 3Cx300sqmm Aluminium 33kV, XLPE Galvanised steel strips armoured power cable with necessary clamps, connectors suitable for connection ofany type of conductor or Al /Cu pipe buswith all accessoriesetc. and suitable clamps for fixing cable to support structure at 1m interval complete 30 Indoor Termination kit Heat Shrinkable Type for 3Cx300sqmm Aluminium 33kV, XLPEGalvanised steel strips armoured power cable with necessary clamps, connectors suitable for connection ofany type of conductor or Al /Cu pipe buswith all accessoriesetc. and suitable clamps for fixing cable to support structure at 1m interval complete 31 Distribution Transformer 11kV/433V, 250 kVA, Star rated (BEE Latest notification as on date of tender)with 11kV & 433V outdoor cable entry box, suitableDistribution Box with LT cable (Trfr to LT box) with 500Amps Fuse and MCCB including all accessories like Busbar, Metering Cabinets etcand its fixing -mounting arrangement on plinth 32 11kV Outdoor type RMU withcombination of 2( two) numbers ofSF6 insulated/arc quenching motorized Load Break Switches and one Vacuum/SF6 breaker suitable for 11KV/433V Auxillary Transformer/ Outgoing feederas per the KSEBL approved make with CT, VT, Control and Protection Relays - Overcurrent/REF etc. and Metering, Indications complete (SCADA compatable) as per the technical specification 33 11kV Outdoor type RMU withcombination of 2( two) numbers ofSF6 insulated/arc quenching motorized Load Break Switches as per the KSEBL approved make with CT, VT, Control and Protection Relays - Overcurrent/REF etc. and Metering, Indications complete (SCADA compatable) as per the technical specification 34 Supply of 11kV indoor VCB 5 panel set with combinations of Incomer feeder panel with PT (1 number), Outgoing feeder panel (3 number) and transfomer panel (1 number) with bay control and protection unit (BCPU) for integration with upstream Substation Automation System (SAS) through HSR/PRP topology (IEC 61850 edt 2 compliant) with protection philosophy specified in technical specification along with supply of accessories necessary for operational spares and special tools (as per attached list clause 37.6 & 38 of volume 2, Chapter 30). Bus Bar ratings are 2000A. Circuit breaker shall be E2 M2 C2 class as per IEC 62271-200. Feeder, transformer and incomer panel shall have capacitive voltage indicators (CVI) and only incomer panel BPCU will have PT inputs. Feeder,transfomrer and incomer panels shall house one each multi-function meter (MFM) and DLMS compatible energy meters. Each Incoming and outgoing feeders shall be equipped with split core type CBCT for Sensitive Earth Fault Protection 35 Supply of Polymeric type LA suitable for 11kV 36 3Cx300sqmm 11kV Aluminium XLPE insulated under ground armoured cable, with necessaryclamps for fixing with support structure at 3 m interval 37 3Cx300sqmm11kV Aluminium XLPE Under ground cable Termination Kit Outdoor Heat Shrinkable 38 3Cx300mm2 11kV Aluminium XLPE Under ground cable Termination Kit Indoor Heat Shrinkable 39 Supply of Hot dip Galvanised LatticeStructurefor 33kV,11kV& 110 kV Switch Yard, Columns/Beams/Pre fabricated Cable Supports in Trenches/lightning mast structure/ lighting mast structure/ equipment structures unless otherwise not specified else where in the BOQ etcinclusive of N&Betc(as per respective Technical Specifications, standards and relevant special conditions). 40 EOT Crane of suitable capacity (minimum 5T safe working load) with single hook and double girder arrangement for GIS Hall. Contractor shall submit the capacity calculation of the crane incorporating 25% additional load considering erection and maintenance of largest GIS component / assembly. 41 DG set 125 kVA silent type, Outdoor plinth mounted withAMF panel, Auto Load Change over module and panels, Battery and its charger, Diesel Tank etc with SAS integration facilities including all accessories complete 42 Battery Set - 110 V, 400Ah , Lead Acid plante Battery SetC10 Duty cycle (Rating is tentative and final sizing as per the load calculation shall be under bidder scope) & Installationwith Battery Racks made with acid proof material ,two number of indsutrial type flame proof exhaust fan and all necessary arrangements including tool kit like hydro meter, chemical gloves, multimeter etc. 43 48V, 200 AH VRLA Battery Set with all associated accessories for reliable communication & data acquistion project complete as per specifications 44 SCADA compatible 110V Dual mode (FC+ BC) Battery Charger, with independent Float (FC)and Boost charging (BC) (2 number rectifier unit) min-FC-80A, BC-80A, suitable for 110V Battery bank as per design and shall charge Battery set as per technical requirement during float /boost mode without interruption to load. The charger shall have two independent incomer supply.(Battery charger shall meet the full DC load during boost condition and the Bidder shall propose the final sizing of the battery charger during detailed engineering for approval)(Both set shall be of different make ) 45 Battery Charger - 48 V Dual mode (FC+BC) (Float - 30A/Boost - 60A) - SCADA compatible, SMPS based,Suitable to VRLA Battery set and shall be able to charge Battery set as per requirement during float /boost mode as well as it shall supply to load as per rated voltage of load components inclusive of necessary power, communication and control cables with all accessories complete -Compact type 46 SCADA compatible DCDB-110 V with minimum 20 + 20 Outgoing feeders duplex type (Floor Mountable) with changeover panel having interlock facility with 20% spare feeder breakers for station control and protection systems as per the station requirement, facility shall be there to charge any battery set with any of the battery chargerwith interlock. Ratings shall be as per the battery sizing calculation. 47 DCDB 48 V with change over facility and min 20 Nos. of Distribution Outlets( 2 Nos.- 10A and 18 Nos. 6A)-DUPLEX Type-SCADA/SAS Compatible-Wall mountable 48 SCADA compatible LT 3 phase 50Hz Panel Boardwith Insulated Aluminium Bus Bar, 2 nos incomers (Auxillary Transformer / DG Set), automatic interlock/load change over facilty, two sets of outgoing,panel with LED indications, panel meters,ACB /MCCB(incomers), MCCB (feeders), Earth Bus bar etc., for LT Power Distribution to Control room/equipments including all accessories complete as perspecifications having minimum 20% spare feeders.Remote operation shall be possible for incomers and DG set.(Panel sizing and rating to be proposed by the bidder during detailed engineering for approval). 49 SCADA compatible LT MLDB/LDB/Street light control DB with Lighting Transformer, Surge Protection Devices, MCCB, MCB, RCCB, ELCB and all accessories complete as per technical specifications for Control Room and Yard lighting including all sub distribution boards, and SCADA compatible ACDB/Sub ACDB for Air Conditioners & AHU with soft starting feature etc. including MCCB, MCB, RCCB, ELCB. (The DB sizing and rating shall be proposed by the bidder, with 20% spare capacity, during detailed engineering for KSEBL approval) 50 SCADA compatible LT Emegency Lighting Distribution Board (ELDB) with 63A Incomer and minimum 12Nos 10A Outgoing Feeders and DC Emegency Lighting Distribution Board (DC ELDB) and related accessories including MCCB/MCB,RCCB/ ELCB as perstandard specifications for Emergency lighting in the substation / Switchyard, charges including all sub distribution boards 51 LT A.C Three Phase Self mounted Indoor Power Kiosk IP 42 with 1 incomer MCCB 63A including indicating lamps,single phase and three phaseindustrial type16A sockets etc. at GIS hall 52 LT A.C Three Phase Self mounted Outdoor Power Kiosk (IP 56) with 1 incomer MCCB 250A, 2 Outgoing MCCB 160A & 100A including indicating lamps,3 phase and singlephase industrial type 16A sockets etc. complete for Transformer oil filteration unit, welding purpose etc. 53 Supply of Protection Panels/Equipments, Substation Automation System and materials as per technical specifications, IS/IEC Standards applicable 54 Control and Protection panel for Transformer with Differential Protection,REF (Transformer management relay) for HV and LV [M1 and M2 relay shall be of different make / platform and each shall have-87, 67/67N, 64R-Low Impedance, Transformer Mechanical Protection- Bucholz, OLTC Bucholz, OLTCPanel Control & signal interfacing with RTCC panel, OTI, WTI, PRD1 &2 through high impedance tripping relays, MOLG Alarms etc.,] 33/110kV 60MVA, with BCU , IEC 61850 Edition 2compatible and provision for interface to SCADA system. Energy meters as per technical specifications and suitable for GIS switchgear modules 55 Busbar Protection panel for8 bays (110kV Bus) as per specifications -with zone segregated tripping, LBB, end zone protection, local HMI for displaying differential current, SLD, Isolator Position etc., with output tripping relays (drawout type) and provision for interface to SCADA/SAS system 56 Control and Protection panels (main 1 and 2- 87L,21,67/67N,50N,59,PSB, 79A/R,49,81 O/U) for 110kV Feeders with BCU , IEC 61850 Edition 2compatible and provision for interface to SCADA systemas per tech specifications and suitable for GIS switchgear modules (M1 and M2 relay shall be of different make / platform and the combination shall exactly suit with the remote end M1 and M2 relays). Over and above the normal Tri-Vector Meter, the contractor should supply SEM Meters as per SRLDC/PGCIL Standards, additionally. 57 Control and Protection panel for 110kV Bus Coupler with BCU and additional Common BCU for Auxiliary control System and Monitoring including the panel as per standard and requirement of 110kV GIS 58 Design, Manufacture and Supply of Complete SAS system for 110kV GIS , as per detailed technical specification , SAS system Architecture andSLD , Reduntant Servers, Reduntant Gateway, Reduntant Routers with Hardware Firewalls,2 Nos Operator Work Station with HMI -Desktop (one operating work station with extended HMI at Nedumkandam (10Km away)) , 2 Nos. Engineering Work Station(Lap top and Desk top) , one metering PC with DCU for SAMAST metering and Remote Station Controls, necessary Panels and Furnitures etc completewith all necessary accessories, cables,converters, GPS based Time Syncronising Unit IEC compatible to cater data to and from all bays and transformer, SCADA compatible panels,interfacing /intergating line differential relay in CR panel, SAS gateway server panel etc to FODP/Communication equipment in communication room as per specification, including supply of all necessary converters for interfacing with the communication equipment , unarmoured OF cable , 40mm PLBHDPE pipe duct , all interconnecting cables , Patch chords devices etc. complete. The scope include integrating 33kV and 11 kV systems.SAS Architecture should be suitable for plug and play integration of future bays. [Including mandatory Spares as specified in volume 2 - Technical Specfications, Chapter 11, Annexure C] 59 Design, Manufacture and Supply of materials / item for Power Cable, Control Cables and instrumentation cable, Supply of various sizes of 1.1 kV FRLS-0H PVC armoured copper cable for control , Aluminum/ Copper LT power cable as per approved cable schedule (to be prepared by contractor and got approved), and provision of all types of cables from Power and Auxilliary Transformer and other equipments/switchgears, for the substation (Aluminium cables of size 185 mm2 and above shall be XLPE type) includingties , tags etc. supply of suitable size PVC pipe and accessoriesfor drawing exposed cables as per the technical specifications, IS/IEC Standards applicable. 60 12x4mm2 Control CableCopper 61 4x6mm2 Control CableCopper 62 4x4mm2 Control Cable Copper 63 2x4mm2 Control Cable Copper 64 19x2.5mm2 Control CableCopper 65 12x2.5mm2 Control Cable Copper 66 7x2.5mm2 Control Cable Copper 67 4x2.5mm2 Control Cable Copper 68 3x2.5mm2 Control Cable Copper 69 2x2.5mm2 Control Cable Copper 70 2x1.5mm2 Control Cable Copper 71 4x0.5mm2 instrumentation Cable Copper 72 4x10mm2 PVC InsulatedLT copper cables 73 2x10mm2 PVC Insulated LT copper cables 74 2x1.5 sq.mm or higher size PVC Insulated shielded copper cables for Transformer OTI & WTI wiring 75 20/25 mm dia FRLS PVC Rigid/Flexible Conduit including all clamps, clips etc. for Fire Alarm Panel and sensor wiring purpose 76 3 1/2C x300 Sqmm 1.1kV LTXLPE insulated armoured Aluminium cable 77 3 1/2C x 240 Sqmm 1.1kV LT XLPE insulated armoured Aluminium cable 78 3 1/2C x 120 Sqmm1.1kV LT XLPE insulated armoured Aluminium cable 79 3 1/2C x 90 Sqmm1.1kV LT XLPE insulated armoured Aluminium cable 80 3 1/2C x 70 Sqmm1.1kV LT XLPE insulated armoured Aluminium cable 81 3 1/2C x 50 Sqmm 1.1kV LT XLPE insulated armoured Aluminium cable 82 3 1/2C x 35 Sqmm1.1kV LT XLPE insulated armoured Aluminium cable 83 3 1/2C x 25 Sqmm1.1kV LT XLPE insulated armoured Aluminium cable 84 4C x 16 Sqmm1.1kV LT XLPE insulated armoured Aluminium cable 85 1x 95 sqmm DC cable (stranded and flexible) NFPA category FRLSLH Copper Cable for battery. 86 1x 70 mm2 DC cable (stranded and flexible) NFPA category FRLSLH Copper Cable for battery. 87 1x35 mm2 DC cable (stranded and flexible) NFPA category FRLSLH Copper Cable for battery. 88 Supplying aluminium cable tags with punching number and alphabets up to 7 digits or higher as per requirement for 220/33/11kV power cables including cost of all materials as per the technical and standard specifications 89 Hot dip galvanized ladder type cable tray with joint plate and N&B size300x100x2 with all accessories complete 90 Hot dip galvanized ladder type cable tray with joint plate and N&B size 450x100x2and with all accessories complete 91 Hot dip galvanized ladder type cable tray with joint plate and N&B size600x100x2 and with all accessories complete 92 Design, Manufacturere, Testing at Manufacturs works, transporation and Delivery of the Conductor/ Earthing Materials and associated materials for Gas Insulated Substation as per technical Specifications and IS/IEC Standards applicable 93 Aluminium Bus bar 120*10mm 94 ACSR Wolf Conductor 95 110 kV 90kN Silicon Composite Longrod Insulator 96 110 kV 70kN Silicon Composite Longrod Insulator 97 110 kV Single Tension H/W and Accessories suitable for Single Wolf 98 110 kV Single Suspension H/W and Accessories suitable for Single Wolf 99 wedge – connector suitale for wolf/Kundah 100 wedge with paddlesuitale for wolf/Kundah 101 Earth Wire 7/3.15 mm Galvanised Steel wire with required hardwares accessories and earthbond 102 Tension Clamp and Tail Clamp for 7/3.15 mm Earth Wire 103 32/40mm MS rod for earthing 104 GI strip all sizes as per requirement for earthing 105 Clamp and saddle for GI strip/wire 106 Test link for lightning protection 107 1.5m GI lightning spike with fixing clamps 108 Design and supply ofVentilation system for GIS hall(positive pressure type)with prefilters and fine filters of washable type for 100% capacity of GIS hall, with air displacement of 5 times the volume of GIS hall per hour (one operating + one standby , consisting of two units each having capacity 5 times air changes per hourof GIS hall workingcyclically for 50% of time)with soft starting feature,comprising of GI ducts( with provision for nitrile rubber insulation if taken externally), fire dampers, exhaust dampers, grills, noise reduction system etc. complete.The system shall be monitored via SCADA including necessaryelectrical panels. 109 Design, Manufacturere, Testing at Manufacturs works, transporation and Delivery of the Fire and Safety Equipments and materials for 33/110kV Gas Insulated Substation as per technical Specifications and IS/IEC Standards applicable- Portable and wheel/ trolley mounted fire extinguishers for Control room 110kV GIS Hall, 110kV Switchyard Relay panel room of GIS Hall,Transformers and other Strategic locations including its installation at site 110 Dry chemical powder of 9kg capacity 111 Dry chemical powder of 25kg capacity 112 Dry chemical powder of 50kg capacity 113 CO2 gas type of capacity 6.5kg 114 CO2 gas type of capacity 22.5kg 115 Mechanical foam type capacity 9LT 116 Mechanical foam type capacity 50LT - 117 Fire Stand with 4 buckets(Including Concreting as per drawings) 118 SCADA compatible - Main Fire Alarm Control Panel (Zone of protection as per approved scheme) complete with Charger, Rectifier, Visual Display, battery back up complete as per the station requirement 119 Photo Electric type Smoke detector with base compatable for Fire Alarm Panel 120 Photo Electric type Heat detector with base compatable for Fire Alarm Panel 121 Supply of Beam Detector and Reflector for GIS with base compatable for Fire Alarm Panel 122 Audio Alarm with Hooters cum Speakers compatable for Fire Alarm Panel 123 Manual Call point of Break Glass Type with hammer and chain 124 Insulating Mat (Size 2000x1000x2mm) class A including its fixing at site as per Technical Specification and IS 125 Safety Chart for First Aid, Electric Shock & Fire and Fire Fighting Equipments including its fixing accessories complete 126 Lighting and General / Miscellaneous Items 127 Optical Fibre Cable (12F Single Mode and 12F Multimode) , SM and MM Patchcords, all necessary connectors complete, as per site requirement for extended HMI, bus bar protection other than SASas per site requirement and technical specification 128 Ground Enhancement Material (GEM) ( Per Bag -11.33 Kgs ) - Conforms IEC 62561-7 Standard. The GEM shall have Resistivity of less than 20 Ohm-cm and Environmental friendly 129 Visual Monitoring System (VMS) with surveilliancecamera as per technical specification and layout drawing (Including local PC monitoring set up having sufficient storage capacity, remote end PC monitoring if necessary set up shall be in the scope of supply) including necessary power and communicationcables, interconnecting hardwares, PVC pipes and all other accessoriesetc complete as per the technical specifications (minimum requirement : Fixed Camera : min 8 Nos, Pan Tilt Zoom Camera : min 2 Nos, Fixed Variable Focus: min 4 Nosand storage >8TB) 130 Design of Air Conditioning system and Supply of5 Star rated (as per latest BEE notification)2TR or higher capacity split type inverter Air Conditioners, with stabilizer, Power Isolator etc.for Control & Relay panel room, Communication room, SCADA room, Bay Control Room (each room has got minimum one unit of redundancy, cyclically operated with Room temperature indicator) as per detailed engineering and approval. Temperature indicators shall be integrated to SCADA 131 SPARES for GIS - 220/110kV 132 Tripping & closing coil(Each Breaker type Module) 133 Motor for disconnector of each type of equipment 134 Motor for CB spring charging (each Breaker Type) 135 SF6 Pressure Guage for Circuit Breaker 136 SF6 Pressure Guage for other compartments 137 SF6 Pressure Relief Device 138 Auxillary contact assembly for Circuit Breaker 139 Auxillary contact assembly for Disconnector/Isolator-each type 140 SF6 gas 141 Moisture absorbant catridge 142 NRV gas filling valve for equipment 143 Indication lamps and lamps for semaphores & annunciators- one for each type & colour 144 Annunciator full set each type with one set of relay card 145 Special tools for Installation and Maintenance -220/110kV 146 Gas Leakage detector - DILO make 147 Special spanners for General maintenance for supplied GIS 148 SF6 gas bottle locking , measuring and filling assembly with whole hose 149 Measuring Instruments 150 Clamp on meter- capable to measure mA range .• High sensitivity, miniature AC/DC clamp meter.Range: 200mA/2/20A AC, 2/20A DCMin. resolution for AC: 0.1mAMin. Resolution for DC: 1mAJaw size: 7.5mm all required accessories from following make and model Fluke,MEGGER,KYORITSU 151 Phase Sequence meter with Standard accessories -Fluke,MEGGER,KYORITSU 152 Digital Multimeter 279FC TRMS Thermal or advancedFluke,MEGGER Model 153 Analog Multimeter, with Standard accessories - Fluke,MEGGER,KYORITSU 154 SF6 gas Analyser including DEW point,purtity & Hygrometer etc.
Contract Date : 01 Apr, 2026   |   Contract Value : 369.42 Crore
Disclaimer

We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.

Tender Detail
Website https://tender.nprocure.com/
Quantity
MSME Exemption No
Tender Type Open Tender
Startup Exemption Click Here
Competitive Bidding NCB
Similar Tenders
TENDER INSIGHTS

858

Electric Tenders
Live
CLICK TO KNOW MAXIMUM WIN

Tell us about your Product / Services,

We will Find Tenders for you

🇮🇳 +91
TenderDetail
Loading tenders