TDR : 56629406
Central Public Works Department

Tender Brief :

Delhi, Delhi

MOEI & Fans I/C Street Light At DMS Colony, Hari Nagar, New Delhi. 2. RMO Water Pumping Sets At DMS Colony, Hari Nagar, New Delhi. (SH: Running Maintenance & Operation, Special Repair Of Internal & External Electrical & Mechanical Installations )

Published: 23 Jul 2026
Opening: 31 Jul 2026
Closing: 31 Jul 2026
Amount: 33.91 Lakhs
EMD: 67824
Tender Fee: Ref. Documents


Works Active Harmonic Filter Actuator Aerial Cable Aerodrome Beacon Air Circuit Breaker
0
Days Left
Tender Summary / Eligibility Criteria
MOEI & Fans I/C Street Light At DMS Colony, Hari Nagar, New Delhi. 2. RMO Water Pumping Sets At DMS Colony, Hari Nagar, New Delhi. (SH: Running Maintenance & Operation, Special Repair Of Internal & External Electrical & Mechanical Installations )
Documents Download All
71d324a1-3711-4d3f-8e5f-7af7b43c1b9e
71d324a1-3711-4d3f-8e5f-7af7b43c1b9e.html
DocumentsList
DocumentsList.zip
No Boq
No Corrigendum
Probable Bidders

AI engine predicts probable bidders to help you bid strategically.

MSME Exception
Explore More →
Technical
Tender involves procurement of high capacity electrical equipment including diaphragm coupling of pump & motor with 90kW capacity at 2900 RPM. The project scope includes installation, testing, commissioning and operational handover.
Previous / Similar Result
BRR : 10648884 Annual Repair And Maintenance Of Various Electrical Installation And Mechanical Equipments Of 119 Type-Iii, Residential Quarters For The Staff Of Gnctd Of Delhi At Sector - 11, Rohini, Delhi. 2 ) Repair Maintenance Of Ei An Fans, Pumpset, Dg Set, Street Light In Division Office And Circle Office -Sub Head - I ( Maintenance Of Ei & Fans At Residential Staff Quarters At Sector - 11, Rohini ) Running Maintenance And Operation Of All Ei Wiring, Light Points / Fan Points / Exhaust Fan Points / Call Bell Points, Light / Power Plug Points, Ac Points, Edb, Main Board, Street Light Points, Glow Sign Boards, Fl. Fittings, Ceiling Fans, Exhaust Fans, Brass Batten / Angle Holder, Call Bells, Buzzer Etc. And Operation Of Drinking And Horticulture Water Pump Sets By Deputing The Following Experience Staff Including Sunday And Holidays As Per Terms And Conditions Attached.Staff Engaged By The Contractora ) Wireman Cum Operator : 02 Nos. In ( One No. In Each Shifts, 6 Am To 2 Pm & 2 Pm To 10 Pm ) B ) Khallasi : 02 Nos. In ( One No. In Each Shifts, 6 Am To 2 Pm & 2 Pm To 10 Pm ) 2 Sub Head - Ii ( Maintenance Of Ei & Fans At Pwd Offices At Below Isbt Flyover ) Maintenance And Upkeeping Of All The Internal Electrical Installations, Pumpsets Including Compound Lights And Recording And Monitoring Of The Complaints Including Cleaning Of All Ei And Fans Etc., Operation Of Water Cooled 25 Kva Dg Set Manually Operated Battery Charger On All Working Days ( Excluding Sundays & Holidays ) In General Shift Complete As Per Terms And Conditions, Detail Of Staff Etc As Required.Staff Engaged By The Contractora ) Wireman Cum Operator : 01 No. In General Shift 3 Supplying Of Following Electrical Accessories ( I / C Dismantling ) Suitable For Existing Different Type Fitting / Switch Box Etc. For Dispensing Complaints On Day To Day Basisas Required . ( Excluding Labour Cost Which Is Already Included In Item 1&2 ) A ) S.P. 5 / 6 A, One Way Switch, Piano Type Isi Marked 4 B ) S.P. 15 / 16 A, One Way Switch, Piano Type Isi Marked 5 C ) 6 Pin 15 / 16 & 5 / 6 A Socket Outlet, Piano Type Isi Marked 6 D ) Piano Type Electronic Fan Regulator Socket Type 7 E ) Ell Push, Piano Type 8 F ) Call Bell / Buzzer, Single Phase 9 G ) 2.5 Mfd Capacitor 10 H ) 3.15 Mfd Capacitor 11 I ) S.P. 5 / 6 A, One Way Modular Switch, Isi Marked 12 J ) 3 Pin 5 / 6 A Modular Socket Outlet, Isi Marked 13 K ) S.P. 15 / 16 A, One Way Modular Switch, Isi Marked 14 L ) 6 Pin 15 / 16 A Modular Socket Outlet, Isi Marked 15 M ) Modular Base & Cover Plate For 3 Module 16 N ) Vc Batten / Angle Holder 17 O ) 3 Mm Thick Phenolic Laminated Sheet 18 P ) 1.5 Sq. Mm Isi Marked, Frls Pvc Insulated, Single Core Copper Conductor Cable 19 Q ) 4.0 Sq. Mm Isi Marked, Frls Pvc Insulated, Single Core Copper Conductor Cable 20 R ) 10 Sq. Mm Isi Marked, Frls Pvc Insulated, Single Core Copper Conductor Cable 21 S ) 4X16 Sq.Mm Aluminium Conductor Armoured Cable 22 T ) 4X35 Sq.Mm Aluminium Conductor Armoured Cable 23 U ) 6 A To 32 A Ratings, Sp Mcb, “C” Curve, 10 Ka Breaking Capacity 24 V ) 6 A To 32 A Ratings, Dp Mcb, “C” Curve, 10 Ka Breaking Capacity 25 W ) 63 A Dp Mcb C Curve 10 Ka Breaking Capacity 26 X ) 63 A Rating, 2 Pole Rccb, 30 Ma 27 Y ) 63 A Fp Mcb C Curve 10 Ka Breaking Capacity 28 Z ) 4 Pole Mccb, 100A, 30Ka 29 Aa ) 4 Pole Mccb, 200A, 36Ka 30 Ab ) 225 / 230 Mm Sweepmetallic Grey1400 Rpm Exhaust Fan 31 Ac ) 300 Mm Metallic Grey 1400 Rpm Exhaust Fan 32 Ad ) 1200 Mm Sweep ( Aluminium Body ) Ac Ceiling Fan Without Regulator 33 Supplying Of Following Ratings Led Fittings Of Colour Temperature 6500K With Minimum Efficacy Of 100 Lumens / Was Follows: A ) 12 W Led Surface Mounted Round Shaped Downlighter 34 B ) 20 W Led Batten Fititng 4 Feet Long Surface Mounted 35 C ) 36 W / 40 W Led Batten Fitting 36 D ) 30 W Led Flood Light Ip65 37 E ) 70 W Led Flood Light Ip 65 38 F ) 30 W Led Street Light Ip 65 39 G ) 70 W Led Street Light Ip 65 40 H ) 200 W Led Flood Light Ip 65 41 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, With Piano Type Switch, Phenolic Laminated Sheet, Suitable Size Ms Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc.As Required ( Group B ) 42 Rewiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable And 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable As Earth Wire In Existing Surface / Recessed Steel / Pvc Conduit Including Dismantling As Required. ( Group B )
Contract Date : Ref. Documents   |   Contract Value : Ref. Documents
BRR : 1639667 Annual Operation And Maintenance Contract For The E And M Installations At Bhavnagar Airport For The Year 2020-22 As Per Special Conditions Of Contract , Annual Operation And Maintenance Of Electrical & Mechanical Installations Of Terminal Building , Air Side & City Side Area Of Terminal Building , Power House , Car Parking Area , Pump Rooms , Glf Installations , Operational Area , Aai Residential Colony , Attending Complaints/Faults/ Breakdowns Ensuring Serviceability , Satisfactory Working Condition Of The System By Carrying Out Preventive Maintenance , Maintaining Records/ Documents As Per Requirements Etc On All Days Including Sundays And Holidays On 3 ( Three ) Shift Basis By Deployning Manpower As Specified In Special Condition Of Contract Etc . As Required . , Inspection , Servicing And Testing Of Crompton Greaves Make 11 Kv Vcb Throughoem Or Authorized Service Provider Of Oem And Submission Of Reports Etc Complete All As Required . , Inspection , Servicing And Testing Of Voltamp Make 500Kva , Transformer Throughoem Or Authorized Service Provider Of Oem Submission Of Reports Etc Complete All As Required . , Filtration And Dehydration Of Transformer Oil Of 500 Kva , 11Kv/433V Distribution Transformers Including Testing The Bdv And Acidity Before And After Filtration Andsubmission Of Test Reports Etc . As Required , Suppling And Toping Up The Transformer Oil In 500 Kva , 11Kv/433V Distribution Transformers Etc Complete All As Required . , Inspection , Servicing , Setting , Calibration And Testing Of L&T Make Relays ( Set Of 2 Over Current Plus 1 Earth Fault ) Through Oem Or Authorised Service Provider Of Oem I/C Carrying Out The Following And Submitting Test Reports . A ) General InspectionB ) Wiring Check C ) Ir Value TestD ) Continuity Of Plug Shifting Taps And Plug Bridge Shorting ContactsE ) Secondary Injection Test Including Pick Up Current Of Idmt Element Etc . , Inspection , Servicing & Testing Of 1250 Amp/1000 Amp/800 Amps L&T Make Air Circuit Breakers Through Oem Or Authorized Service Provider Of Oem I/C Carrying Out The Following Test And Submission Of The Test Reports . A ) General InspectionB ) Wiring Checking Including Control And IndicationsC ) Ir Test Between Poles , Between Pole To Earth Between Male And Female ContactsD ) Continuity Of Power Contacts . E ) Continuity Of Auxiliary ContactsF ) Resistance Measurement Of Tripping CoilG ) Closing , Tripping And Inter- Locking TestingH ) Tripping Through Relay OperationI ) Secondary Injection Test Of In-Built Thermal And Magnetic Release And Calibration Of The Same , Carrying Out Calibration And Sensitivity Of Relay Of Following Capacity Nasu Make Constant Current Regulator ( Ccr ) By Oem And Submission Of Reports Etc . , Complete As Required . , 30 Kw , 20 Kw , 4 Kw , Rewinding And Servicing Of Ceiling Fan/ Wall Fan/Exhaust Fan With Copper Wire Of Required Size , Replacement Of Defective Bearing And Bush I/C To And Fro Transportation Etc . Complete As Required . ( All The Dismantle Material Belongs To Contractor ) , Ceiling Fan Of All Size , Wall Fan , Exhaust Fan , Rewinding & Servicing Of The Following Capacity Submersible Motor Pump Sets With Suitable Gauge Copper Wire I/C Varnishing , Baking , Replacement Of Faulty Bush & Bearing Etc As Required I/C Transportation From Site To Contractors Workshop & Back To Site . ( Dismantle Material Belongs To Contractor ) . , 7 . 5Hp , 10 Hp , Rewinding And Servicing Of The 1 Hp Motor Pump Sets With Suitable Gauge Copper Wire I/C Varnishing , Baking Replacement Of Faulty Bearing And Bushing Etc As Required I/C Transportation From Site To Contractors Workshop & Back To Site . ( Dismantle Material Belongs To Contractor , Painting Of Street Light Pole Of Following Height By Applying 2 Coats Of Aluminium Paint Of Approved Make Including Pole Boxes , Brackets , Cleaning Of Surface Etc . , As Required Including Rewriting The Pole Identification Serial Number Etc Complete All As Required . , Up To 3 Mtr , Above 3 Mtrs And Upto 10 Mtr , Perimeter Lighting Pole Up To 3 Mtr , Painting Of Hirl / Mirl / Sapl Fitting I/C Base Plate In Installation Position With Two Coats Of Synthetic Enamel Paint Of Yellow Colour Of Approved Make To Given An Even Shade Including , Cleaning The Surface With Detergent , Etc . Removing Old Paints Etc . As Required . , Painting Of Following Equpment By Applying Two Coats Of Synthetic Enamel Paint Of Yellow Colour Of Approved Make To Given An Even Shade Including , Cleaning The Surface With Detergent , Etc . Removing Old Paints Etc . As Required . , Papi Units I/C Base Plate , H Indicator I/C Base Plate , Painting Of Sheet Metal Enclosures Of Electrical Equipments Such As Feeder Pilars , Distribution Boards , Electrical Panel , Frame Etc . Including Cleaning The Surface And Two Coats Of Grey Or Any Other Colour Of Approved Make Including Rewritting/Marking The Identification , Protecting And Covering The Electrical Accessories During Painting And Removing After Work Is Over Etc . , As Required . , Decoration Of Terminal Building And Associated Area On The Following Special Occassions/Nationally Important Days/Festivals By Providing Led Serial Lighting And Rgb Type Colour Changing Led Light , Creating Special Effects As Per The Nature Of Occassion Up To The Satisfaction Of Eic Including Providing And Fixing Of All The Accessories , Tools & Plants , Arranging Manpower , Transportation Of Materials Complete As Per The Requirements Shown Below - ( I ) Minimum No . Of Led Serial Lighting - Not Less Than 5000 Led Lights . ( Ii ) Rgb Pattern Colour Changing Led Lighting For Pillars Of Terminal Building And For Creating Special Effect As Per Reqirement ( Iii ) Pixel Chaser Light Batten ( With Minimum 12 Colour Combinations ) Running Linearly On The Top Of The Building For Alength Of Not More Than 200 M . , On The Occasion Of Independence Day/ Republic Day Starting From 18 . 00 Hrs On Day Before The Occassion To 06 . 00 Hrs On The Day Afterthe Occasion . , On The Occasion Of Diwali Starting From 18 . 00 Hrs . Before02 Days Ofdiwali Till 06 . 00 Hrs On Day After Bhai Dhooj I . E . Minimum 04 Days . , On The Occasion Of Christmas And New Year Starting From 18 . 00 Hrs . Of 24Th December Till 06:00 Hours Of 1St Januarary I . E Minimum 07 Days . , Tracing/Finding Of Cable Fault Ofall Type Of1 . 1 Kv Grade Lt Power Cable Of Different Sizes I . E . 3 . 5X25 Sq . Mm To 3 . 5X300 Sq . Mm Al Cable By Standard High Precision Cable Fault Locator Machinen . The Job Also Includes Excavation Of All Type Of Soil To Dig Out The Cable For Rectification Of Fault At The Location Of Fault Etc Complete All As Required , Calibration Of Papi Clinometer And Submission Of Calibration Certificate Etc . Complete As Required . , Testing , Servicing , Adjustment And Calibration Of Different Types Measuring Instruments Such As Digital Insulator Tester/Digital Multimeter/ Digital Clamp Meter/ Digital Varnier Calipers/ Digital Earth Resistance Testing Meter/Digital Thermometer/Digital Lux Meter And Submission Of Calibration Certificate For Each Instrument Etc . Complete As Required . , Execution Of Complete Items Of Cpwd Delhi Schedule Of Rates ( E&M ) 2018 . [Up To A Ceiling Limit Of Rs . 1 , 00 , 000 Without Gst] . The Materials Used For Executing The Dsr Items Shall Be As Per The Approved Make List Of Aai , As Enclosed With The Tender Document .
Contract Date : 01 Sep, 2020   |   Contract Value : 84 Lakhs
BRR : 9460337 tender for Baruasagarnagar Palikaparishad Reorganization Water Supply Scheme Under Amrut 2.0 Survey Soil Investigation Design Supply Of All Materials Labour Tandp Etc Required For Construction Erection Completion Testing And Commissioning Of Water Supply Works Such As Wtp Rcc Oht Zps Cwr Cum Pumping Station Rising Main Feeder Main, BARUASAGAR NAGAR PALIKA PARISHAD REORGANIZATION WATER SUPPLY SCHEME UNDER- AMRUT 2.0, DISTT. JHANSI Sl. No. Item Description 1 CIVIL WORK 2 Survey, Soil investigation,(including topographical survey, geotechnical investigation and other Surveys as required) for Design and Drawing, Supply of all materials, labour, T&P etc. required for construction,of specified capacity (3.6MLD) of WTP based on 20 Hrs. operation (3.6MLD + 25%) extra over loading capacity includinginlet chamber, aeration fountain / cascade, inlet channels including mechanical/manual fine/coarse screens, flash mixer, mixing channel with Parshall flume and flow measuring arrangement, clariflocculator with conventional, filter house and filter plant including back wash tank and back wash pumps with 100% standby, chemical house, coagulant feed tank with feed mechanism, poly aluminium chloride (PAC) or other coagulant tank of specified capacity and nos. with mixing and dosing arrangement complete, vacuum feed gas chlorinator with 100% standby, sludge handling unit and recycling of collected water from sludge etc. complete,All WTP scada Opratedexternal and internal electrification, laboratory building with all specified lab equipment, admin building, Quarter (One no.), sanitary block with necessary water supply and drainage arrangement, campus roads, landscaping and other campus development works, rain water harvesting, etc. all required works complete as per the direction of Engineer-in-Charge.The WTP shall be fully automatic based on PLC/SCADA with real time remote monitoring system and online contineuous effluent monitoring system. 3 For water works compound Construction of Bituminious approach road including preparation of subgrade. 4 Earth filling inside the water works campus. 5 Cutting of bushes, removing garbage form w/w site and dewatering of sub soil water at wtp & including maintinance of existingintake well Painting of intake well and existing water works campus 6 CONSTRUCTION OF SUMP-CUM-CLEAR WATER RESERVOIR-CUM-PUMP HOUSE OF 250 KL CAPACITY AT ZONE-3WATER WORKS CAMPUS (CWR) 7 RCC CWR;Detailed Survey, Design and Drawing, supply of all material, labour, T&P etc. required for construction of250 KL Ractangular, R.C.C Clear Water Reservoir cum pump house including various works like 1 m wide stair case with stainless steel hand railing to go inside reservoir, sump below the pump house area, stainless steel railing over the R.C.C slab of reservoir, Granular texture finish on exterior surface of pump house, gantry beam, food grade epoxy coating of FOSROC / Ciba-Geigy or reputated brand on inside surface area of water container after testing for water tightness, kota ston floring,bypass arangment ,and soil testing for Bearing capacity of capacity mentioned as under:Note : The bid prices of Clear Water Reservoir / Pumping Stations are to be submitted considering the depth of excavation may extend up to 6 m BGL. Design and Drawing approved by competent authority and Design vetted by Reputed Govt. Engineering College.(250 KL capecity) 8 Survey, Soil investigation,(including topographical survey, geotechnical investigation and other Surveys as required) for , Design,Drawing includingSupply of all materials, labour, T&P etc. required for construction, Construction ofLT Panel Room (RCC Frame Structure) as per type design (5m x 5m x 4 m) 9 Survey, Soil investigation,(including topographical survey, geotechnical investigation and other Surveys as required) for , Design,Drawing includingSupply of all materials, labour, T&P etc. required for construction, Construction ofMeterRoom (RCC Frame Structure) as per type design (4m x 4m x 4 m) 10 Estimate of RCC OverHead Tank of 450 KL. Capacity / 22 M. Staging FOR ZONE -3 Barua Sagar 11 450 KL 22 M Staging Survey Design , drawing and Supply of all materials, labour and T&P etc. complete for the construction of OHT of 450 KL. capacity and staging 22 M with 1.00 m. wide P.C.C. appron all around with 15 cm. Semi circular P.C.C. drain, 1 m. wide RCC stair case from ground level upto balcony, M.S. Ladder with hand rails on both sides from balcony to top dome and inside the tank, 1 m wide RCC balcony alround the tank wall with proper railings of 20 mm. dia. medium quality G.I. pipes in 3 rows on both sides of staircase, balcony and at the top of domes and at each landing supported on RCC posts spaced at not more than 1.50 m. intervals, proper ventilators at top, electronic water level indicator with invertor, Lightening conductor as per latest I.S. code or electricity rules, 600 mm. dia. medium pattern C.I. Manhole cover hinged with locking arrangement, fixing and jointing vertical DID/F pipes, specials and duck foot bends of required size for Inlet, outlet, fixing of outlet sluice valve and washout sluice valves with all jointing materials for proper completion and other appurtenant works, including excavation in all type of soils, painting on exposed surface with one coat of primer and two coats of approved weather coat paint, painting of vertical pipes and railings with approved anticorrosive paints and also including testing of the Overhead Tank, including following items : Supply of following sizes of DID/F pipes conforming to IS 8329 / 2000 or its latest amendment upto rail head including all taxes, duties, insurance etc. Inlet pipe 250 mm. dia.,Outlet pipe 300 mm. dia.,Overflow pipe 300 mm. dia.Washout pipe 100 mm. dia.Carting of above size DI K-9 of pipes upto site of works and lowering them into the trenches and laying true to alignment and gradient and jointing of pipes complete ( including testing of pipelines and cutting of pipes for making up the length excluding the cost of trenches. ) Inlet pipe 350 mm. dia. Outlet pipe 400 mm. dia. Overflow pipe 300 mm. dia. Washout pipe 100 mm. dia . Supply of following diameter ISI Mark Sluice Valve conforming to IS 780/ 1984 or its latest amendment of standard make ( Kirloskar or IVC make ) including all taxes etc. and carting, loading and uploading upto departmental store and carting of following fittings / specials to the site of work, lowering them into the trenches, fixing in position and jointing them with pipe lines, fixing in position and jointing them with pipelines and testing etc. complete including supply of all jointing materials. 400 mm. dia. ( In outlet pipe )100 mm. dia. ( In washout pipe ) Supply of all materials, labours, T&P etc. all complete to construct sluice valve chamber of following sizes.For Outlet Pipe For Washout Pipe Provision for the disposal of overflow water, washout water from chambers to nearest suitable point of disposal including supply of pipes, its laying, jointing, excavation and protection works at the point of disposal. including Provision for soil testing. 12 DISTRIBUTION SYSTEM OF BARUASAGAR ZONE-1,2 and 3 and CLEAR WATERGRAVITY MAIN FROM WTP TO ZONAL WATER WORKS AND RISING MAIN FORZONES-03 (Chui Khadan) BARUASAGAR NAGAR PALIKA PARISHAD 13 Excavation for pipe line trenches in soil mix / all type of rocks with moorum/shingles/kanker requiring use of special T&P ie. pick axe, sabbals etc. lift upto 1.50 m lead upto 50 m. stacking and spreading as directed, normal dewatering,preparing the bed,Filling watering ramming of excavated earth into pipe line trenches and disposal of surplus earth upto a distance of 10 KM from the centre of the pipe line trenches 14 0.00 To 1.5 m Depth 15 Same as above but excavation in all type of rock 16 0.00 To 1.5 m Depth 17 Supply of ISI mark DI K-9 and K-7 S&S pipes (push on joints) of following class and diameters inclusive of jointing material (Rubber gasket of EPDM Quality IS 12820 / 1989) andand Supply of specialsconforming to IS 8329/2000 for its latest ammendment F.O.R. desination rates per meter (exclusive of GST) in Rs. every where in UP upto stores of consignees inclusive of third party inspection chacking and forwarding charges, transit insurance charges, road transportation charges, unloading & stacking the same etc. with jointing Materials including all taxes, freight, loading, unloading, insurance, duties etc., all complete. and supply of all DI DF/DI DS specialslike Tees, all type bend ( For Distribution, Feedermain And Rising main Purpose ) 18 80 mm Dia DI K-7 19 100 mm diaDI K-7 20 125 mm diaDI K-7 21 150 mm diaDI K-7 22 200 mm dia Distribution system and Junction (B-D) to Cwr at zone -3DI K-7 23 250 mm diaDI K-7 24 200 mm dia DI-K-9 25 Lowering, laying and jointing with SBR ruber gasketsD.I. K-7/ D.I. K-9 of various classes with DI / MS specials of following diameter in proper position, grade and alignment including conveyance of material to site of work. It also includes cost of jointing materials and rubber rings labour,hydraulic testing etc. complete.Carting of following sizes (Dia. in mm.) of pipes and specials including jointing mateirals from store to site of work lowering the same into excavated pipe line trenches true to alignment and gradient and jointing the same including testing of pipe line including supply of all materials labour T&P etc complete and as per direction of Engineer Incharge. 26 80 mm Dia 27 100 mm dia 28 125 mm dia 29 150 mm dia 30 200 mm dia Distribution system and Junction (B-D) to Cwr at zone -3 31 250 mm dia 32 200 mm dia DI-K9 Zone-3 33 Supply of following type of valves as per specifications F.O.R. desination rates per meter (exclusive of GST) in Rs. every where in UP upto stores of consignees inclusive of third party inspection charges, packing and forwarding charges, transit insurance charges, road transportation charges, unloading & stacking the same etc. complete.Double flanged Ductile Iron Sluice valves as per IS 14840 : 2000 PN 1.0 34 D.I.Sluice valve 35 100 mm dia 36 150 mm dia 37 200 mm dia 38 250 mm dia 39 Fire Hydrant as per IS Code 908 : 1975 40 65 mm Dia 41 Air valves as per IS 14845 : 2000 PN 1.0 42 50 mm Dia 43 20mm Dia 44 Scour valves 45 50 mm dia 46 Carting, lowering, laying, aligning, fixing in position and installation of following valves in pipe line including all material, labour, testing and commissioning as per direction of Engineer-in- charge.Double flanged Ductile Iron Sluice valves as per IS 14840 : 2000 PN 1.0 47 100 mm dia 48 150 mm dia 49 200 mm dia For Zone -3 50 250 mm dia 51 Fire Hydrant as per IS Code 908 : 1975 52 65 mm Dia 53 Air valves as per IS 14845 : 2000 PN 1.0 54 50 mm Dia 55 20 mm Dia 56 Scour valves 57 50 mm dia 58 Supply of all materials, labour, T&P etc. required for construction of following masonry type chambers as per type design. 59 Sluice valve chambers (Masonry type) 60 100 mm to 250 mm dia 61 Scour valve chambers (Masonry type) 62 Fire hydrantschambers 63 Air valve chambers 64 Dismantling (cutting by sharp eage machine tools) and Reinstatment of following type of road surfaces for laying of pipe line and house connection work including sorting out of serviceable materials and disposal of unserviceable materials. 65 Bituminious Road 66 Cement Concrete Road (CC) 67 Interlocking Tiles Road 68 Construction of thurst block in RCC 1:2:4 at bends & Tee in feeder main including supply of all labour, material, T&P etc. complete as per the details given below :- 69 Mild steel or iron work in R.C.C. wrought to required shape as necessary including bending for proper completion of the work including supply of steel and wastage etc. 70 Provision for crossing of Nalas (0.5mto 2.0 m innerwidth) for laying of pipe line including necessary specials, T&P and arrangement of diversion of water, baricatings etc required, with dismantelling of drains and reconstruction of same as per type design of the existing drain. 71 0.5 - 1.0 m 72 1.0 - 1.5 m 73 1.5 - 2.0 m 74 Providing new water supply house connection to the consumersfrom new distribution pipe line of following diametersincluding making ferrule connection, cost of ferrule, 15 mm dia HDPE and GI pipe, saddle piece, ball valve, specials, excavation, refilling of pit etc. complete. It also includes supply of all materials, labour, T&P Including Dismentling and Reinstatment etc. required for proper completion of the work. As per attached drawing. 75 In all tupe of soil and rock 76 Bituminious Road 77 For 80 to 100 mm dia 78 For 125 to 150 mm dia 79 For 200 mm dia 80 Cement Concrete Road 81 For 80 to 100 mm dia 82 For 125 to 150 mm dia 83 For 200 mm dia 84 Interlocking Tiles Road 85 For 80 to 100 mm dia 86 For 125 to 150 mm dia 87 For 200 mm dia 88 Kachha Road 89 For 80 to 100 mm dia 90 For 125 to 150 mm dia 91 For 200 mm dia 92 Repairing of drain/ public ramp/other miscellaneous structures which are coming in alignment of pipe line and damaged during the laying of pipe line including supply of all materials, labour, T&P etc. required for proper completion of the work. 93 Brick masonry in cement mortar 1:4 94 12mm thick plaster in cement mortar 1:4 95 RCC M-20 (including MS work) 96 Stone masonry in cement mortar 1:6 97 Shifting of Existinghouse connection from existing pipe line to new pipe line including supply of all materials, labour, T&P etc. required for proper completion of the work. 98 Repairing of house connection which is coming in alignment of pipe line and damaged during the laying of pipe line including supply of all materials, labour, T&P etc. required for proper completion of the work. 99 Barricating of pipe line trenches by using bamboo poles,sheets, rope with red flags, Glow-caution boards, diversion boards & red lights Complete as per the direction of engineer incharge 100 Interconnection of existing pipe line to new pipe line including fitting special pipe, tee, bend, reducer pipe all complete as per site requirment T&P etc material complete as per the direction of engineer incharge 101 80 mm dia 102 100 mm dia 103 125 mm dia 104 150 mm dia 105 Disposal of surplus earth includingmoorum/stone bolder /building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge. 106 Boundary wallat zone -3 (chhui khadan) Rcc column based boundary wall as per design 30x50 m BOUNDARY WALL Construction of Boundry wall around campus as per unit estimate with RCC Columns @ 3.0m c/c distance with plinth beam and brick work including supply of all Materials, Labour, Tools and Plants etc. complete., as per departmental type drawing.Construction of2.0 meter high compound wall from formation level of campus,comprising of 230mmx230mm RCC Columns @ 3.0 m c/c distance with 230 mm thick beam at plinth and top, brick work of 230 mm thick in 1:4 and 12 MM THICK 1:4 cement plaster over all surface of wall , two coat of Exterior emulsion paint of approved reputed make over one coat of primer and even surface preparation by applying 2-3 layer of approved reputed make Puttyas perdesign approved by engineer in Charge, including supply of all material, labour, T& P etc complete. 107 3.60 m wide mild steel gate with rcc columns with 1.0 m wicket gate 108 earth filingincludingmoorum/stone bolder /building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge. 109 Provide all materials, labour and T&P to construct single roomed staff quarter as per type design and quantities of unit estimate all complete , including common stair case and other miscellaneous works. The plinth area of each staff quarter is 57.706 sqm.Detailed Survey, Design& Drawing, Construction of Residential Building based Office Building on R.C.C frame structure at different location finished with all respect, flooring made up with vitrified Tile/ Kota stone , Flush door shutter , glazed window cum ventilation including mosquito proof shutter, waterproofing at roof , anti-skid tile at toilet / bathroom / kitchen , water supply and sanitary work & electrification with all fixture, painting with 3 coat apex at exterior surface and emulsion at interiorsurface including2 coat Birla white puttyofbuilding, apron around building, appropriate size of septic tank and soak pit, including supply of all material, labour, T&P complete as per the direction of the engineer in charge 110 Plinth area of building 57.706 Sqm 111 Re-instatement of following type of road surfaces after laying of pipe line and house connection work including supply of all materials, T&P etc. requuired for proper completion of the work as per direction of engineer-in-charge. The quantity of re-instatement has been increased by thirty percent in the view of additional damaged of dismantled road due to traffic / vehicle movemen 112 Bitumen roadTYPE AConstruction of bitumen road as per UPPWD specification including supply of all materials, labour, T&P etc. required for proper completion of work as per following thickness:-GSB G-1 (One coat) (90-40 mm) = 12.5 cmG -2 (one coat) (45-63 mm) = 7.5 cmG - 3 (one coat) (22.5 - 53 mm) = 7.5 cmBM (One coat)= 7.5 cmSDBC (One coat)= 2.5 cm 113 TYPE BConstruction of bitumen road as per UPPWD specification including supply of all materials, labour, T&P etc. required for proper completion of work as per following thickness:-Bitumen Road (SDBC + Tack coat)SDBC (One coat)= 2.5 cmTack coat with bituminous emulsion (MS)= 0.25 kg/sqm(30% consider for over dismantling of existing road) 114 Cement Concrete Road(100mm Thick PCC 1:4:8 and 100mm Thick CC 1:2:4) 115 C.C. Interlocking Tiles Road Type AConstruction of 80 mm tihck C.C. Interlocking Tile road including supply of all materials, labour, T&P etc. required for proper completion of work as per following thickness:-PCC = 100 mm,1:4:8 (cement, coarse sand & stone ballast of 20-40 mm)Sand= 50 mm thick local sand lair for preparation of surfaceTiles = 30% new + 70% old 116 E and M Work 117 PUMPING PLANT AND ACCESSORIES FOR EXISTING INTAKE WELL ( ZONE-1) KHANDI (2.5 MLD) 118 Supply of Vertical type self-oil lubricated statically, dynamically, hydraulically balanced turbine pumpcapable of discharging at thefollowingdutyconditionasgivenbelowduetoallcauseswith surface discharge head confirming to IS:1710 and as amended as on date with accessories as per IS 5120/1977(Reconfirmed 2011) and as amendedthereaftertosuitthesitecondition.ThePumpBowlassembly and casing shall be CI IS 210 FG: 260 with suitable coating inside casing of 500 DFT, suitable for protection against corroision,erosion and prevent oxidation.Impeller and Wearing / Neckringshall be Duplex stainless steel CD4MCu (Chromium-24.5% minimum,Carbon < 0.04% ) as per ASTM A890 GrlA or DIN 1.4474-EN 10088, Hardness 220-260 BHN,pump shaft-Stainless steel AISI 410, pumps and line shaft sleeve - stainless steel with ceremic coating 700 BHN,Strainer-SS 304,coupling between pump ang motor - Flexible pin bush type and bearings shall be Anti friction L-10 with 60000 Hrs life at 1450 rpm.14mtr/suitablelengthcolumnassembly, with vertical Solid shaft Squirrel cage induction motor(IS:126152011/IEC60034-1)suitablefortheabovepump continuous rated TEFC IP-55 with Class F insulation for operation in AC, three Phase/50 HZ (±5%), 415V (±10%), running with a speed of pump. Capacity as follows :- 119 2050LPM, 25.00 HP, 37m Head 120 MAIN PIPING AND VALVES :-Supply of 150mm Main piping & valves complete of suitable size and quantity required for delivery side, bye pass arrangement and 150mm common Header upto 1 m. outsidethe pump house along with 150 x 150 x 150 mm A/F Tee,150 mm bend, 150 mm blind flange, D/F Pipes suitable sizeall necessary nuts, bolts, rubber packing, M.S Support for pipe,mechanical joints and valve etc. complete in all respect as per site conditions. 121 Motor operated actuator with sluice valve :- Supply of DI/DF sluice valve withElectrically integrated actuater (Totally enclosed,weather-proofanddustproofconstructionwithIP-67, protectionclass suitable for installationin any positionwithout lubrication,leakageorotheroperationaldifficultywithspecialgrease filledgearboxandsuitableformanualoperationforemergencywhich will automatically dis-engage on restoration of power to motor and with10wattsingle phase spaceheaterandcontinuouslocalmechanical positionindicatorandindividuallyreplaceablecountergearassembly and with two torque and four limit switches with S.S. flap and operated withgeardrivencamsandofrating250Volt,5Amp,AC/DC,torque switch dialand with TEFC squirrel cageinduction) operatedsuitable to SCADAoperationsluicevalvehavingbodydoorcoverof gradedincast irontoIS:210Gr.Fg.260bodyanddoorringsofSSASTMA743Gr.CF8 andbearingblockofleadedtinbronzetoIS:318Gr.LTB2hingepinof stainlesssteelAISI:431.ValvesgenerallyconformtoIS:5312.Flangesto bedrilledasperIS:1538Part-IV&VI. Valves aresuitable for hydrostatictestpressureof10Kg./Cm2 forseatand15Kg./Cm2for body(PN-1.0)of following sizes 122 Valve actuator of size 150mm for pumps and common header 123 Non return valve :- Supply of DI/DF Single Door/ Multi Door Non return/reflux valve conforming to IS:5312/2003(partI & II) PN-1.0 to be fixed after pumps for 90% fast closing & 10% slow closing . 124 150 mm Dia 125 CE/UL Certified Electromagnetic flow meter :- SupplyofCE/ULFullBorecElectromagneticFlowMeterofapproved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated), Pressure:upto1.0 MPa,Processtemp:-50degC, Flow/MeterTube:SS304, Electrode:SSAISI316L/ HastelloyC276/ Tantalum, Lining Material : Hard Rubber/ Neoprene/ Poly-urethane(PU), Flange: SS /CS, FlangeStandard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Càst Aluminium,with anticorrosivepaint&providecompletely sealed (leak proof) constructionasperrequirement‘ofIEC 60529, Accuracy : + 0.5 % M.V. velocity0.3to10m/s,Transmitter/signaconvertor Enclosure :Die CastAluminium, Power Supply: 80-240 V AC-5OHz,Output1: 4-20 mA,Output2:Pulse,CommunicationOutput:RS485/Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable. 126 Electromagnetic flow meter of size 150mm for common header 127 ELECTRICAL ITEMS:- 128 Supply& laying of 1.1KV grade XLPE insulated unarmured multi strand copper conductor cable of 3C x 16sq.mmfrom control Panel to respective Motors with lugs etc. (copperconductor should be electrlytic grade copper, purity >99.97% ISI marked asper IS:1554 P-I / IS :7098 P I) 129 MOTOR CONTROL CENTER (MCC) PANEL :-Single front, Indoor & floor mounted,cubical type Panel factory fabricated (2 mm thick for sructure, 1.6mm thick for door,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coateddust and vermin proof IP-54 /IS:2147, considered Earth Bus-Bar-GI Strip compitableto SCADA operation with RS485 Port consisting ofINCOMMING SECTION125A,50KA,TPN,ACB microprocessorbaseed (O/C,S/C)release-1 No , Spreader Links & Extended ROH for - 1 No, 3 Phase Digital MultifunctionMeter -1No,DigitalVoltmeter0-500V -1No,Digital Ammeter 0-400A- 1 Nos, CT For meter Resin Cast CL-1400A/5A,15VA - 3 Nos, Phase indication light LED type 220V AC - 1 Set, Control MCB SP 6A ,10KA ABB - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Link - 1 No.OUTGOING SECTION80 A, 50KA, TPN, MCCBmicroprocessorbased (O/C,S/C) RELEASE - 3 No, SpreaderLinks &Extended ROH for MCCB- 3 Nos., 63A TPN MCCB 35KA- 2 Nos. Terminal 63A 130 CE/UL Certified level transmitter for Intake well :- SupplyofCE/ULcirtifiedof RadarleveltransmitterCEmarkedwith following technical parameters and Interfacing with PLC panel including mounting arrangement.Output-4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 131 CE/UL Certified Pressure transmitter :- Supply of CE/UL Certified pressure transmitter CE markd with following technical parameters and Interfacing with PLC panel includingmounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 132 CE/UL Certified Pressure transmitter for pumps 133 CE/UL Certified Pressure transmitter forCommon Header 134 Earthingwithcopperearthplate600mmX600mmX3mmthick including accessories, and providing masonry enclosure with cover plate havinglockingarrangementandwateringpipeof2.7metrelongetc. with charcoal/ coke and salt as required according to latest IS:3043Supplyingandlaying50mmX6mmG.I. stripat0.50metrebelow groundas stripearth electrode, including connection/ terminatingwith nut,bolt,spring,washeretc.asrequired.(Jointingshallbedoneby overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 135 Installation of all equipments, power wiring of Electrical equipments and commissioning of the pumping plants 136 RubbermatsforelectricalpurposeasperIS:5424-1969, plain/chequered (1mX2m) - 10mm thickness 137 Cable trench Chequerred plate 138 Fire fighting equipments 4.5 Kg such as four nos. fire extinguishers ABC type, one set sand bucket with stand and grouting at site and one set Al strong plate and board. 139 Internal & External electrification of pumping station. 140 PUMPING PLANT AND ACCESSORIES FOR EXISTING INTAKE WELL ( ZONE-2)FOR (3.20 MLD+3.50 MLD) 141 Supply of Vertical type self-oil lubricated statically, dynamically, hydraulically balanced turbine pumpcapable of discharging at thefollowingdutyconditionasgivenbelowduetoallcauseswith surface discharge head confirming to IS:1710 and as amended as on date with accessories as per IS 5120/1977(Reconfirmed 2011) and as amendedthereaftertosuitthesitecondition.ThePumpBowlassembly and casing shall be CI IS 210 FG: 260 with suitable coating inside casing of 500 DFT, suitable for protection against corroision,erosion and prevent oxidation.Impeller and Wearing / Neckringshall be Duplex stainless steel CD4MCu (Chromium-24.5% minimum,Carbon < 0.04% ) as per ASTM A890 GrlA or DIN 1.4474-EN 10088, Hardness 220-260 BHN,pump shaft-Stainless steel AISI 410, pumps and line shaft sleeve - stainless steel with ceremic coating 700 BHN,Strainer-SS 304,coupling between pump ang motor - Flexible pin bush type and bearings shall be Anti friction L-10 with 60000 Hrs life at 1450 rpm.14mtr/suitablelengthcolumnassembly, with vertical Solid shaft Squirrel cage induction motor(IS:126152011/IEC60034-1)suitablefortheabovepump continuous rated TEFC IP-55 with Class F insulation for operation in AC, three Phase/50 HZ (±5%), 415V (±10%), running with a speed of pump. Capacity as follows :- 142 2500LPM, 30.00 HP, 37m Head 143 MAIN PIPING AND VALVES :-Supply of 200mm Main piping & valves complete of suitable size and quantity required for delivery side, bye pass arrangement and 250mm common Header upto 1 m. outsidethe pump house along with 250 x 200 x 250 mm A/F Tee,250 mm bend, 250 mm blind flange, D/F Pipes suitable sizeall necessary nuts, bolts, rubber packing, M.S Support for pipe,mechanical joints and valve etc. complete in all respect as per site conditions. 144 Motor operated actuator with sluice valve :- Supply of DI/DF sluice valve withElectrically integrated actuater (Totally enclosed,weather-proofanddustproofconstructionwithIP-67, protectionclass suitable for installationin any positionwithout lubrication,leakageorotheroperationaldifficultywithspecialgrease filledgearboxandsuitableformanualoperationforemergencywhich will automatically dis-engage on restoration of power to motor and with10wattsingle phase spaceheaterandcontinuouslocalmechanical positionindicatorandindividuallyreplaceablecountergearassembly and with two torque and four limit switches with S.S. flap and operated withgeardrivencamsandofrating250Volt,5Amp,AC/DC,torque switch dialand with TEFC squirrel cageinduction) operatedsuitable to SCADAoperationsluicevalvehavingbodydoorcoverof gradedincast irontoIS:210Gr.Fg.260bodyanddoorringsofSSASTMA743Gr.CF8 andbearingblockofleadedtinbronzetoIS:318Gr.LTB2hingepinof stainlesssteelAISI:431.ValvesgenerallyconformtoIS:5312.Flangesto bedrilledasperIS:1538Part-IV&VI. Valves aresuitable for hydrostatictestpressureof10Kg./Cm2 forseatand15Kg./Cm2for body(PN-1.0)of following sizes 145 Valve actuator of size 200mm for pumps 146 Valve actuator of size 250mm for common header 147 Non return valve :- Supply of DI/DF Single Door/ Multi Door Non return/reflux valve conforming to IS:5312/2003(partI & II) PN-1.0 to be fixed after pumps for 90% fast closing & 10% slow closing . 148 200 mm Dia for pumps 149 250 mm Dia for common header 150 CE/UL Certified Electromagnetic flow meter :- SupplyofCE/ULFullBorecElectromagneticFlowMeterofapproved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated), Pressure:upto1.0 MPa,Processtemp:-50degC, Flow/MeterTube:SS304, Electrode:SSAISI316L/ HastelloyC276/ Tantalum, Lining Material : Hard Rubber/ Neoprene/ Poly-urethane(PU), Flange: SS /CS, FlangeStandard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Càst Aluminium,with anticorrosivepaint&providecompletely sealed (leak proof) constructionasperrequirement‘ofIEC 60529, Accuracy : + 0.5 % M.V. velocity0.3to10m/s,Transmitter/signaconvertor Enclosure :Die CastAluminium, Power Supply: 80-240 V AC-5OHz,Output1: 4-20 mA,Output2:Pulse,CommunicationOutput:RS485/Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable. 151 Electromagnetic flow meter of size 250mm for common header 152 ELECTRICAL ITEMS:- 153 Supply& laying of 1.1KV grade XLPE insulated unarmured multi strand copper conductor cable of 3C x 25 sq.mmfrom control Panel to respective Motors with lugs etc. (copperconductor should be electrlytic grade copper, purity >99.97% ISI marked asper IS:1554 P-I / IS :7098 P I) 154 MOTOR CONTROL CENTER (MCC) PANEL :-Single front, Indoor & floor mounted,cubical type Panel factory fabricated (2 mm thick for sructure, 1.6mm thick for door,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coateddust and vermin proof IP-54 /IS:2147, considered Earth Bus-Bar-GI Strip compitableto SCADA operation with RS485 Port consisting ofINCOMMING SECTION250A,50KA,TPN,ACB microprocessorbaseed (O/C,S/C)release-1 No , Spreader Links & Extended ROH for - 1 No, 3 Phase Digital MultifunctionMeter -1No,DigitalVoltmeter0-500V -1No,Digital Ammeter 0-400A- 1 Nos, CT For meter Resin Cast CL-1400A/5A,15VA - 3 Nos, Phase indication light LED type 220V AC - 1 Set, Control MCB SP 6A ,10KA ABB - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Link - 1 No.OUTGOING SECTION100 A, 50KA, TPN, MCCBmicroprocessorbased (O/C,S/C) RELEASE - 3 No, SpreaderLinks &Extended ROH for MCCB- 3 Nos., 63A TPN MCCB 35KA- 2 Nos. Terminal 63A 155 CE/UL Certified Pressure transmitter :- Supply of CE/UL Certified pressure transmitter CE markd with following technical parameters and Interfacing with PLC panel includingmounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 156 CE/UL Certified Pressure transmitter forpumps 157 CE/UL Certified Pressure transmitter forCommon Header 158 Earthingwithcopperearthplate600mmX600mmX3mmthick including accessories, and providing masonry enclosure with cover plate havinglockingarrangementandwateringpipeof2.7metrelongetc. with charcoal/ coke and salt as required according to latest IS:3043Supplyingandlaying50mmX6mmG.I. stripat0.50metrebelow groundas stripearth electrode, including connection/ terminatingwith nut,bolt,spring,washeretc.asrequired.(Jointingshallbedoneby overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 159 Installation of all equipments, power wiring of Electrical equipments and commissioning of the pumping plants 160 RubbermatsforelectricalpurposeasperIS:5424-1969, plain/chequered (1mX2m) - 10mm thickness 161 RENNOVATION OF EXISTING 160 KVA SUB STATION AT INTAKEWELL 162 Supplying of indoor type floor mounted metal clad, 11 KV VCB panel with 1No. VCBs, totally enclosed & fully interlocked, horizontal drawout, horizontal/ vertical isolation type breaker as per IS 13118, as amended up to date and additional specifications, having capacities as mentioned below, single break, trip free mechanism, manually charged and auto/manually closing breaker suitable for use on 11 KV, 3 Phase, 50 Hz A.C. supply with short circuit fault level of 100 KVa, complete with self contained, fully interlocked, rack in and rack out mechanism, air insulated but encapsulated copper bus bars of 1600Amps capacity, breaker featured with mechanical ON/OFF indicator with hand trip device, spring release coil, shunt trip coil and auxiliary switch of 4 NO+4NC and equipped with following switchgears and accessories i/c connections suitable for 11 KV cable (cable entry from *bottom/ top/side) end termination with heat shrinkable jointing material etc. as required. (Note- Cost of end termination not included in this item)(a) Incoming – ½* No 800Amp. VCB(b) 1* No. – 11 KV / 110 Volts PT Class 0.5 accuracy and 100 VA burder with 1 No. Voltmeter (0-15KV), analog/digital* type, selector switch for voltmeter and protection fuses/MCB for HT metering upto 12 KV on incomer.(c) 1* No. – (0-100 A) dual scale Ammeter, analog/digital* type, selector switches for ammeters.(d) 1* No. – Microprocessor based numerical relay with O/L, E/F and S/C protection.(e)1* No. – Set of dual core dual ratio 3 CTs 300/150/5/5 A of 15 VA burden and accuracy Class – 0.5 for metering and class 5P10 for protection.(a) Outgoing – 2Nos. 800Amp. VCB(b) 2Nos. – (0-100 A) Ammeters, dual scale analog/digital* type & selector switches for Ammeters.(c) 2 Nos. – Microprocessor based numerical relays with O/L, E/F & S/C protections.(d) 2 Nos. – Setofdualcoredualratio3CTs 100/ 50/5/5 A of 15 VA burden and accuracy Class-1.0 for metering and class 5P10 for protection.1. Supply of power pack 24 volts complete with battery and charging device. 163 Supply of 50 Sq.mm size XLPE cable from 11 K.V.UPPCL metering panel to 11 KV incoming H.T. switch gear panel and panel to transformer. 164 Supplying of 160KVA, 11/0.415 KV, 3 Phase, 50 Hz, Dyn 11, indoor ONAN type, copper wound transformer with OFF load tap changing arrangement on HV side in steps of +/- 2.5% & -7.5%, having cable end boxes on HV side suitable for 3x150sqmm XLPE cable of 33 KV grade and bus trunking arrangement on LV side complete with all accessories i/c first filling of filtered dehydrated oil and confirming to IS 1180 & as per specification attached complete in all respects as required at site. 165 Supplying of cubicall type LT panel suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system fabricated in compartmentalized (preferably) design from CRCA sheet steel of 2 mm thick for framework and covers, 3 mm thick for gland, plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having 630Amp capacity extensible type TPN aluminium alloy bus bars of hight conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 31 MVA for 1 Sec., bottom base channel of MS section not less than100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth barof size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from mainbus bar to switch gears with required size of Al. bus bars and control wiring with 50sq. mm. PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears :-(I) Incoming : 2 Nos.. 630 Amps horizontal drawout type air circui+B12t breaker of fault breaking capacity 50 KA (Ics=Icu upto433 V manually operated, fitted with interlocked door, automatic safety shutters, mechanical ON/ OFF and service/test/isolated position indicators and frame earthing contact, conforming to IS 1397- 2 : 1993 as amended up-to-date complete with following accessories for each ACB.(a) Independent manual spring closing mechanism- 1 No.B10(b) Microprocessor release (EMI & EMC certified) for over current, earth fault & short circuit protection- 1 set.(c) Analog 96 mm square flush pattern /Digital* type Voltmeter (0-500 V), with selector switch & back up HRC fuses/ MCBs-1 set.(d) Analog 96 mm. square flush pattern/ Digital* type Ammeter (0-630Amp), with selector switch and one set of 3 nos. CT’s of ratio10/5A Class I accuracy and 15 VA burden- 1set. (e) 3 Nos. Phase indication LED lamps with2 Amp back up HRC fuse, breaker ‘ON’ indicating light with 2 A HRC fuse, test terminal block set, fuses, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required.(f) Shunt trip coil 220 V A.C.(II) Bus Couplers :1Nos. 630Amps drawout type, air circuit breakers offault breaking capacity 50 KA (Ics=Icu upto433 V) manually operated, with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators and frame earthing contact conforming to IS 13947- 2 : 1993 as amended upto date complete with following accessories for each ACB:(a) Independent manual spring closing mechanism- 1 No.(b) Breaker ‘ON’ indicating light with back up 2 A HRC fuse test terminal block, fuses, circuits contactors for positive electrical interlocking of breakers, etc. as required- 1 set.(III) Bus Bars :TPN aluminium bus bars of minimum of 630Amps capacity with heat shrinkable coloured sleeves and i/c DMC/SMC bus bar cross section, size supports & their spacing etc. for withstanding fault level of 31 MVA for 1 Sec. 166 (IV) Interlocking :Electrical through advance contacts in ACB’s (incomers & bus couplers) and mech- anical (castel key) interlocking should beprovided to ensure that only one supply is available at a time on each section of bus and to eliminate any possiblility of accidentally approaching two supplies at one bus section.(V) Outgoing :(a) 1Nos. 630Amp 4 Pole ACB (Ics = kA upto 433 V)/SFU with HRC fuse (BC : 80 kA)(b) CT’s of ratio 10/5Amps 4Nos.4Set (1 set of 2 Nos.)(c) Analog 96 mmsq/Digital* type ammeter (0-100Amp) with selector switch set. 167 Supply and laying of 650/1100 volt grade 185 sq mm 3½ core PVC Armoured Aluminium cable from transformer to L.Tpanel and from outgoing panel to distribution panel (1x3½x185 sq mm) 168 Making Earth pit for earthing complete in all respect. Earthing system shall executed as per IS:3043 and I.E. rules. 169 Installation and commissioning of 11 KV/0.4 KV substations including HT Panels and L.T. main control panel including all labor T&P complete in all respect. 170 Supply and making of indoor cable end termination joint kit of size 70 sq mm 3 core for 11 KV H.T. XLPE cable 171 Supply and making of outdoor cable end termination joint kit of size 240 sq mm 3 core for 11 KV H.T. XLPE cable 172 Provision for routine testing of equipments such as transformer, HT Panels and main LT Panel at manufacturer’s works. 173 NOC from Electrical safety department for all field installations such as pumping plants, substation etc.( 11KV Power connection is already available at site. 174 PUMPING PLANT AND ACCESSORIES FROM CWR TO OHT AT WTP ( EXISTING 125KL/20 M ) 175 Supply ofEnergy Efficient Totally Enclosed Fan Cooled (TEFC) Squirrel Cage Induction Motor (IE2) ( Enclosure conforming to protection IP55) Horizontal Foot Mounted Induction Motor, continuously rated suitable for operation on 415+/-10% ,50Hz+/-5% , A.C. supply with class F insulation for 50 Deg. C ambient temperature and altitude less than 1000 M above MSL and conforming to IEC:60034-1 & IS 12615:2018. with pump with following specifications. 176 1845 LPM, 25.00 HP, 32m Head 177 MAIN PIPING AND VALVES :-Supply of 150mm Main piping & valves complete of suitable size and quantity required for delivery side and 150mm common Header upto 1 m. outsidethe pump house along with 150 x 150 x 150 mm A/F Tee,150 mm duckfoot bend, Enlargers, 150 mm blind flange, D/F Pipes suitable sizeall necessary nuts, bolts, rubber packing, M.S Support for pipe,mechanical joints and valve etc. complete in all respect as per site conditions suitable for above pumping plants. 178 Motor operated actuator with sluice valve :- Supply of DI/DF sluice valve withElectrically integrated actuater (Totally enclosed,weather-proofanddustproofconstructionwithIP-67, protectionclass suitable for installationin any positionwithout lubrication,leakageorotheroperationaldifficultywithspecialgrease filledgearboxandsuitableformanualoperationforemergencywhich will automatically dis-engage on restoration of power to motor and with10wattsingle phase spaceheaterandcontinuouslocalmechanical positionindicatorandindividuallyreplaceablecountergearassembly and with two torque and four limit switches with S.S. flap and operated withgeardrivencamsandofrating250Volt,5Amp,AC/DC,torque switch dialand with TEFC squirrel cageinduction) operatedsuitable to SCADAoperationsluicevalvehavingbodydoorcoverof gradedincast irontoIS:210Gr.Fg.260bodyanddoorringsofSSASTMA743Gr.CF8 andbearingblockofleadedtinbronzetoIS:318Gr.LTB2hingepinof stainlesssteelAISI:431.ValvesgenerallyconformtoIS:5312.Flangesto bedrilledasperIS:1538Part-IV&VI. Valves aresuitable for hydrostatictestpressureof10Kg./Cm2 forseatand15Kg./Cm2for body(PN-1.0)of following sizes 179 Valve actuator of size 150mm for pumps 180 Valve actuator of size 150mm for common header 181 Non return valve :- Supply of DI/DF Single Door/ Multi Door Non return/reflux valve conforming to IS:5312/2003(partI & II) PN-1.0 to be fixed after pumps for 90% fast closing & 10% slow closing . 182 150 mm Dia for pumps 183 150 mm Dia for common header 184 CE/UL Certified Electromagnetic flow meter :- SupplyofCE/ULFullBorecElectromagneticFlowMeterofapproved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated), Pressure:upto1.0 MPa,Processtemp:-50degC, Flow/MeterTube:SS304, Electrode:SSAISI316L/ HastelloyC276/ Tantalum, Lining Material : Hard Rubber/ Neoprene/ Poly-urethane(PU), Flange: SS /CS, FlangeStandard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Càst Aluminium,with anticorrosivepaint&providecompletely sealed (leak proof) constructionasperrequirement‘ofIEC 60529, Accuracy : + 0.5 % M.V. velocity0.3to10m/s,Transmitter/signaconvertor Enclosure :Die CastAluminium, Power Supply: 80-240 V AC-5OHz,Output1: 4-20 mA,Output2:Pulse,CommunicationOutput:RS485/Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable. 185 Electromagnetic flow meter of size 150mm for common header 186 Electromagnetic flow meter of size 250mm at CWR Inlet 187 ELECTRICAL ITEMS:- 188 Supply& laying of 1.1KV grade XLPE insulated unarmured multi strand copper conductor cable of 3C x 16 sq.mmfrom control Panel to respective Motors with lugs etc. (copperconductor should be electrlytic grade copper, purity >99.97% ISI marked asper IS:1554 P-I / IS :7098 P I) 189 MOTOR CONTROL CENTER (MCC) PANEL :-Single front, Indoor & floor mounted,cubical type Panel factory fabricated (2 mm thick for sructure, 1.6mm thick for door,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coateddust and vermin proof IP-54 /IS:2147, considered Earth Bus-Bar-GI Strip compitableto SCADA operation with RS485 Port consisting ofINCOMMING SECTION125A,50KA,TPN,ACB microprocessorbaseed (O/C,S/C)release-1 No , Spreader Links & Extended ROH for - 1 No, 3 Phase Digital MultifunctionMeter -1No,DigitalVoltmeter0-500V -1No,Digital Ammeter 0-400A- 1 Nos, CT For meter Resin Cast CL-1400A/5A,15VA - 3 Nos, Phase indication light LED type 220V AC - 1 Set, Control MCB SP 6A ,10KA ABB - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Link - 1 No.OUTGOING SECTION80 A, 50KA, TPN, MCCBmicroprocessorbased (O/C,S/C) RELEASE - 3 No, SpreaderLinks &Extended ROH for MCCB- 3 Nos., 63A TPN MCCB 35KA- 2 Nos. Terminal 63A 190 CE/UL Certified level transmitter for CWR :- SupplyofCE/ULcirtifiedof RadarleveltransmitterCEmarkedwith following technical parameters and Interfacing with PLC panel including mounting arrangement.Output-4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 191 CE/UL Certified Pressure transmitter:- Supply of CE/UL Certified pressure transmitter CE markd with following technical parameters and Interfacing with PLC panel includingmounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 192 CE/UL Certified Pressure transmitter for pumps 193 CE/UL Certified Pressure transmitter forCommon Header. 194 Supply and fixing of Electro Mechanical type Chemical dosing system 0 to 6 LPH capacity on working pressure 4kg/cm2 to feed Sodium hypo chloride complete set with 100 Litre solution tank.(Competible to SCADA) 195 Earthingwithcopperearthplate600mmX600mmX3mmthick including accessories, and providing masonry enclosure with cover plate havinglockingarrangementandwateringpipeof2.7metrelongetc. with charcoal/ coke and salt as required according to latest IS:3043Supplyingandlaying50mmX6mmG.I. stripat0.50metrebelow groundas stripearth electrode, including connection/ terminatingwith nut,bolt,spring,washeretc.asrequired.(Jointingshallbedoneby overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 196 Installation of all equipments, power wiring of Electrical equipments and commissioning of the pumping plants 197 RubbermatsforelectricalpurposeasperIS:5424-1969, plain/chequered (1mX2m) - 10mm thickness 198 Fire fighting equipments 4.5 Kg such as four nos. fire extinguishers ABC type, one set sand bucket with stand and grouting at site and one set Al strong plate and board. 199 Internal & External electrification of CWR 200 PUMPING PLANT AND ACCESSORIES FROM CWR TO CWR HILLOCK ( EXISTING 850 KL) 201 Supply ofEnergy Efficient Totally Enclosed Fan Cooled (TEFC) Squirrel Cage Induction Motor (IE2) ( Enclosure conforming to protection IP55) Horizontal Foot Mounted Induction Motor, continuously rated suitable for operation on 415+/-10% ,50Hz+/-5% , A.C. supply with class F insulation for 50 Deg. C ambient temperature and altitude less than 1000 M above MSL and conforming to IEC:60034-1 & IS 12615:2018. with pump with following specifications. 202 1845 LPM, 20.00 HP, 22m Head 203 MAIN PIPING AND VALVES :-Supply of 150mm Main piping & valves complete of suitable size and quantity required for delivery side and 300mm common Header upto 1 m. outsidethe pump house along with 150 x 150 x 150 mm A/F Tee,150 mm duckfoot bend, Enlargers, 150 mm blind flange, D/F Pipes suitable sizeall necessary nuts, bolts, rubber packing, M.S Support for pipe,mechanical joints and valve etc. complete in all respect as per site conditions suitable for above pumping plants. 204 Motor operated actuator with sluice valve :- Supply of DI/DF sluice valve withElectrically integrated actuater (Totally enclosed,weather-proofanddustproofconstructionwithIP-67, protectionclass suitable for installationin any positionwithout lubrication,leakageorotheroperationaldifficultywithspecialgrease filledgearboxandsuitableformanualoperationforemergencywhich will automatically dis-engage on restoration of power to motor and with10wattsingle phase spaceheaterandcontinuouslocalmechanical positionindicatorandindividuallyreplaceablecountergearassembly and with two torque and four limit switches with S.S. flap and operated withgeardrivencamsandofrating250Volt,5Amp,AC/DC,torque switch dialand with TEFC squirrel cageinduction) operatedsuitable to SCADAoperationsluicevalvehavingbodydoorcoverof gradedincast irontoIS:210Gr.Fg.260bodyanddoorringsofSSASTMA743Gr.CF8 andbearingblockofleadedtinbronzetoIS:318Gr.LTB2hingepinof stainlesssteelAISI:431.ValvesgenerallyconformtoIS:5312.Flangesto bedrilledasperIS:1538Part-IV&VI. Valves aresuitable for hydrostatictestpressureof10Kg./Cm2 forseatand15Kg./Cm2for body(PN-1.0)of following sizes 205 Valve actuator of size 150mm for pumps 206 Valve actuator of size 150mm for common header 207 Non return valve :- Supply of DI/DF Single Door/ Multi Door Non return/reflux valve conforming to IS:5312/2003(partI & II) PN-1.0 to be fixed after pumps for 90% fast closing & 10% slow closing . 208 150 mm Dia for pumps 209 150 mm Dia for common header 210 CE/UL Certified Electromagnetic flow meter :- SupplyofCE/ULFullBorecElectromagneticFlowMeterofapproved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated), Pressure:upto1.0 MPa,Processtemp:-50degC, Flow/MeterTube:SS304, Electrode:SSAISI316L/ HastelloyC276/ Tantalum, Lining Material : Hard Rubber/ Neoprene/ Poly-urethane(PU), Flange: SS /CS, FlangeStandard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Càst Aluminium,with anticorrosivepaint&providecompletely sealed (leak proof) constructionasperrequirement‘ofIEC 60529, Accuracy : + 0.5 % M.V. velocity0.3to10m/s,Transmitter/signaconvertor Enclosure :Die CastAluminium, Power Supply: 80-240 V AC-5OHz,Output1: 4-20 mA,Output2:Pulse,CommunicationOutput:RS485/Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable. 211 Electromagnetic flow meter of size 150mm for common header 212 Electromagnetic flow meter of size 250mm at CWR Inlet 213 ELECTRICAL ITEMS:- 214 Supply& laying of 1.1KV grade XLPE insulated unarmured multi strand copper conductor cable of 3C x 16 sq.mmfrom control Panel to respective Motors with lugs etc. (copperconductor should be electrlytic grade copper, purity >99.97% ISI marked asper IS:1554 P-I / IS :7098 P I) 215 MOTOR CONTROL CENTER (MCC) PANEL :-Single front, Indoor & floor mounted,cubical type Panel factory fabricated (2 mm thick for sructure, 1.6mm thick for door,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coateddust and vermin proof IP-54 /IS:2147, considered Earth Bus-Bar-GI Strip compitableto SCADA operation with RS485 Port consisting ofINCOMMING SECTION100A,50KA,TPN,ACB microprocessorbaseed (O/C,S/C)release-1 No , Spreader Links & Extended ROH for - 1 No, 3 Phase Digital MultifunctionMeter -1No,DigitalVoltmeter0-500V -1No,Digital Ammeter 0-400A- 1 Nos, CT For meter Resin Cast CL-1400A/5A,15VA - 3 Nos, Phase indication light LED type 220V AC - 1 Set, Control MCB SP 6A ,10KA ABB - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Link - 1 No. OUTGOING SECTION63 A, 50KA, TPN, MCCBmicroprocessorbased (O/C,S/C) RELEASE - 6 No, SpreaderLinks &Extended ROH for MCCB- 6 Nos., 63A TPN MCCB 35KA- 2 Nos. Terminal 63A 216 CE/UL Certified level transmitter for CWR :- SupplyofCE/ULcirtifiedof RadarleveltransmitterCEmarkedwith following technical parameters and Interfacing with PLC panel including mounting arrangement.Output-4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 217 CE/UL Certified Pressure transmitter:- Supply of CE/UL Certified pressure transmitter CE markd with following technical parameters and Interfacing with PLC panel includingmounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 218 CE/UL Certified Pressure transmitter for pumps 219 CE/UL Certified Pressure transmitter forCommon Header. 220 Supply and fixing of Electro Mechanical type Chemical dosing system 0 to 6 LPH capacity on working pressure 4kg/cm2 to feed Sodium hypo chloride complete set with 100 Litre solution tank.(Competible to SCADA) 221 Earthingwithcopperearthplate600mmX600mmX3mmthick including accessories, and providing masonry enclosure with cover plate havinglockingarrangementandwateringpipeof2.7metrelongetc. with charcoal/ coke and salt as required according to latest IS:3043 Supplyingandlaying50mmX6mmG.I. stripat0.50metrebelow groundas stripearth electrode, including connection/ terminatingwith nut,bolt,spring,washeretc.asrequired.(Jointingshallbedoneby overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 222 Installation of all equipments, power wiring of Electrical equipments and commissioning of the pumping plants 223 RubbermatsforelectricalpurposeasperIS:5424-1969, plain/chequered (1mX2m) - 10mm thickness 224 Fire fighting equipments 4.5 Kg such as four nos. fire extinguishers ABC type, one set sand bucket with stand and grouting at site and one set Al strong plate and board. 225 Internal & External electrification of CWR 226 PUMPING PLANT AND ACCESSORIES FROM CWR WTP TO OHT 350 KL / 22 M 227 Supply ofEnergy Efficient Totally Enclosed Fan Cooled (TEFC) Squirrel Cage Induction Motor (IE2) ( Enclosure conforming to protection IP55) Horizontal Foot Mounted Induction Motor, continuously rated suitable for operation on 415+/-10% ,50Hz+/-5% , A.C. supply with class F insulation for 50 Deg. C ambient temperature and altitude less than 1000 M above MSL and conforming to IEC:60034-1 & IS 12615:2018. with pump with following specifications. 228 1680LPM, 30.00 HP, 44m Head 229 MAIN PIPING AND VALVES :-Supply of 150mm Main piping & valves complete of suitable size and quantity required for delivery side, bye pass arrangement and 100mm common Header upto 1 m. outsidethe pump house along with 150 x 200 x 150 mm A/F Tee,200 mm duckfoot bend, 200 mm blind flange, D/F Pipes suitable sizeall necessary nuts, bolts, rubber packing, M.S Support for pipe,mechanical joints and valve etc. complete in all respect as per site conditions. 230 Motor operated actuator with sluice valve :- Supply of DI/DF sluice valve withElectrically integrated actuater (Totally enclosed,weather-proofanddustproofconstructionwithIP-67, protectionclass suitable for installationin any positionwithout lubrication,leakageorotheroperationaldifficultywithspecialgrease filledgearboxandsuitableformanualoperationforemergencywhich will automatically dis-engage on restoration of power to motor and with10wattsingle phase spaceheaterandcontinuouslocalmechanical positionindicatorandindividuallyreplaceablecountergearassembly and with two torque and four limit switches with S.S. flap and operated withgeardrivencamsandofrating250Volt,5Amp,AC/DC,torque switch dialand with TEFC squirrel cageinduction) operatedsuitable to SCADAoperationsluicevalvehavingbodydoorcoverof gradedincast irontoIS:210Gr.Fg.260bodyanddoorringsofSSASTMA743Gr.CF8 andbearingblockofleadedtinbronzetoIS:318Gr.LTB2hingepinof stainlesssteelAISI:431.ValvesgenerallyconformtoIS:5312.Flangesto bedrilledasperIS:1538Part-IV&VI. Valves aresuitable for hydrostatictestpressureof10Kg./Cm2 forseatand15Kg./Cm2for body(PN-1.0)of following sizes 231 Valve actuator of size 150mm for pumps 232 Valve actuator of size 200mm for common header 233 Valve actuator of size 300mm at OHT Outlet 234 Non return valve :- Supply of DI/DF Single Door/ Multi Door Non return/reflux valve conforming to IS:5312/2003(partI & II) PN-1.0 to be fixed after pumps for 90% fast closing & 10% slow closing . 235 150 mm Dia for pumps 236 200 mm Dia for common header 237 CE/UL Certified Electromagnetic flow meter :- SupplyofCE/ULFullBorecElectromagneticFlowMeterofapproved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated), Pressure:upto1.0 MPa,Processtemp:-50degC, Flow/MeterTube:SS304, Electrode:SSAISI316L/ HastelloyC276/ Tantalum, Lining Material : Hard Rubber/ Neoprene/ Poly-urethane(PU), Flange: SS /CS, FlangeStandard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Càst Aluminium,with anticorrosivepaint&providecompletely sealed (leak proof) constructionasperrequirement‘ofIEC 60529, Accuracy : + 0.5 % M.V. velocity0.3to10m/s,Transmitter/signaconvertor Enclosure :Die CastAluminium, Power Supply: 80-240 V AC-5OHz,Output1: 4-20 mA,Output2:Pulse,CommunicationOutput:RS485/Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable. 238 Electromagnetic flow meter of size 200mm for common header 239 Electromagnetic flow meter of size 300mm at CWR Inlet 240 Electromagnetic flow meter of size 300mm at OHT Outlet 241 ELECTRICAL ITEMS:- 242 Supply& laying of 1.1KV grade XLPE insulated unarmured multi strand copper conductor cable of 3C x 25 sq.mmfrom control Panel to respective Motors with lugs etc. (copperconductor should be electrlytic grade copper, purity >99.97% ISI marked asper IS:1554 P-I / IS :7098 P I) 243 MOTOR CONTROL CENTER (MCC) PANEL :-Single front, Indoor & floor mounted,cubical type Panel factory fabricated (2 mm thick for sructure, 1.6mm thick for door,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coateddust and vermin proof IP-54 /IS:2147, considered Earth Bus-Bar-GI Strip compitableto SCADA operation with RS485 Port consisting ofINCOMMING SECTION250A,50KA,TPN,ACB microprocessorbaseed (O/C,S/C)release-1 No , Spreader Links & Extended ROH for - 1 No, 3 Phase Digital MultifunctionMeter -1No,DigitalVoltmeter0-500V -1No,Digital Ammeter 0-400A- 1 Nos, CT For meter Resin Cast CL-1400A/5A,15VA - 3 Nos, Phase indication light LED type 220V AC - 1 Set, Control MCB SP 6A ,10KA ABB - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Link - 1 No. OUTGOING SECTION100 A, 50KA, TPN, MCCBmicroprocessorbased (O/C,S/C) RELEASE - 6 No, SpreaderLinks &Extended ROH for MCCB- 6 Nos., 63A TPN MCCB 35KA- 2 Nos. Terminal 63A 244 CE/UL Certified level transmitter:- SupplyofCE/ULcirtifiedof RadarleveltransmitterCEmarkedwith following technical parameters and Interfacing with PLC panel including mounting arrangement.Output-4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 245 CE/UL Certified level transmitter for CWR 246 CE/UL Certified level transmitter for OHT 247 CE/UL Certified Pressure transmitter :- Supply of CE/UL Certified pressure transmitter CE markd with following technical parameters and Interfacing with PLC panel includingmounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 248 CE/UL Certified Pressure transmitter for pumps 249 CE/UL Certified Pressure transmitter forCommon Header, OHT outlet etc. 250 Supply and fixing of Electro Mechanical type Chemical dosing system 0 to 6 LPH capacity on working pressure 4kg/cm2 to feed Sodium hypo chloride complete set with 100 Litre solution tank.(Competible to SCADA) 251 Earthingwithcopperearthplate600mmX600mmX3mmthick including accessories, and providing masonry enclosure with cover plate havinglockingarrangementandwateringpipeof2.7metrelongetc. with charcoal/ coke and salt as required according to latest IS:3043 Supplyingandlaying50mmX6mmG.I. stripat0.50metrebelow groundas stripearth electrode, including connection/ terminatingwith nut,bolt,spring,washeretc.asrequired.(Jointingshallbedoneby overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 252 Installation of all equipments, power wiring of Electrical equipments and commissioning of the pumping plants 253 RubbermatsforelectricalpurposeasperIS:5424-1969, plain/chequered (1mX2m) - 10mm thickness 254 Fire fighting equipments 4.5 Kg such as four nos. fire extinguishers ABC type, one set sand bucket with stand and grouting at site and one set Al strong plate and board. 255 Internal & External electrification of Pump house 256 PUMPING PLANT AND ACCESSORIES FROM CWR WTP TO EXISTING OHT 1100 KL / 17 M 257 Supply ofEnergy Efficient Totally Enclosed Fan Cooled (TEFC) Squirrel Cage Induction Motor (IE2) ( Enclosure conforming to protection IP55) Horizontal Foot Mounted Induction Motor, continuously rated suitable for operation on 415+/-10% ,50Hz+/-5% , A.C. supply with class F insulation for 50 Deg. C ambient temperature and altitude less than 1000 M above MSL and conforming to IEC:60034-1 & IS 12615:2018. with pump with following specifications. 258 1680LPM, 25.00 HP, 34m Head 259 MAIN PIPING AND VALVES :-Supply of 150mm Main piping & valves complete of suitable size and quantity required for delivery side, bye pass arrangement and 100mm common Header upto 1 m. outsidethe pump house along with 150 x 200 x 150 mm A/F Tee,200 mm duckfoot bend, 200 mm blind flange, D/F Pipes suitable sizeall necessary nuts, bolts, rubber packing, M.S Support for pipe,mechanical joints and valve etc. complete in all respect as per site conditions. 260 Motor operated actuator with sluice valve :- Supply of DI/DF sluice valve withElectrically integrated actuater (Totally enclosed,weather-proofanddustproofconstructionwithIP-67, protectionclass suitable for installationin any positionwithout lubrication,leakageorotheroperationaldifficultywithspecialgrease filledgearboxandsuitableformanualoperationforemergencywhich will automatically dis-engage on restoration of power to motor and with10wattsingle phase spaceheaterandcontinuouslocalmechanical positionindicatorandindividuallyreplaceablecountergearassembly and with two torque and four limit switches with S.S. flap and operated withgeardrivencamsandofrating250Volt,5Amp,AC/DC,torque switch dialand with TEFC squirrel cageinduction) operatedsuitable to SCADAoperationsluicevalvehavingbodydoorcoverof gradedincast irontoIS:210Gr.Fg.260bodyanddoorringsofSSASTMA743Gr.CF8 andbearingblockofleadedtinbronzetoIS:318Gr.LTB2hingepinof stainlesssteelAISI:431.ValvesgenerallyconformtoIS:5312.Flangesto bedrilledasperIS:1538Part-IV&VI. Valves aresuitable for hydrostatictestpressureof10Kg./Cm2 forseatand15Kg./Cm2for body(PN-1.0)of following sizes 261 Valve actuator of size 150mm for pumps 262 Valve actuator of size 200mm for common header 263 Valve actuator of size 400mm at OHT Outlet 264 Non return valve :- Supply of DI/DF Single Door/ Multi Door Non return/reflux valve conforming to IS:5312/2003(partI & II) PN-1.0 to be fixed after pumps for 90% fast closing & 10% slow closing . 265 150 mm Dia for pumps 266 200 mm Dia for common header 267 CE/UL Certified Electromagnetic flow meter :- SupplyofCE/ULFullBorecElectromagneticFlowMeterofapproved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated), Pressure:upto1.0 MPa,Processtemp:-50degC, Flow/MeterTube:SS304, Electrode:SSAISI316L/ HastelloyC276/ Tantalum, Lining Material : Hard Rubber/ Neoprene/ Poly-urethane(PU), Flange: SS /CS, FlangeStandard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Càst Aluminium,with anticorrosivepaint&providecompletely sealed (leak proof) constructionasperrequirement‘ofIEC 60529, Accuracy : + 0.5 % M.V. velocity0.3to10m/s,Transmitter/signaconvertor Enclosure :Die CastAluminium, Power Supply: 80-240 V AC-5OHz,Output1: 4-20 mA,Output2:Pulse,CommunicationOutput:RS485/Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable. 268 Electromagnetic flow meter of size 200mm for common header 269 Electromagnetic flow meter of size 300mm at CWR Inlet 270 Electromagnetic flow meter of size 400mm at OHT Outlet 271 ELECTRICAL ITEMS:- 272 Supply& laying of 1.1KV grade XLPE insulated unarmured multi strand copper conductor cable of 3C x 16 sq.mmfrom control Panel to respective Motors with lugs etc. (copperconductor should be electrlytic grade copper, purity >99.97% ISI marked asper IS:1554 P-I / IS :7098 P I) 273 MOTOR CONTROL CENTER (MCC) PANEL :-Single front, Indoor & floor mounted,cubical type Panel factory fabricated (2 mm thick for sructure, 1.6mm thick for door,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coateddust and vermin proof IP-54 /IS:2147, considered Earth Bus-Bar-GI Strip compitableto SCADA operation with RS485 Port consisting ofINCOMMING SECTION200A,50KA,TPN,ACB microprocessorbaseed (O/C,S/C)release-1 No , Spreader Links & Extended ROH for - 1 No, 3 Phase Digital MultifunctionMeter -1No,DigitalVoltmeter0-500V -1No,Digital Ammeter 0-400A- 1 Nos, CT For meter Resin Cast CL-1400A/5A,15VA - 3 Nos, Phase indication light LED type 220V AC - 1 Set, Control MCB SP 6A ,10KA ABB - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Link - 1 No. OUTGOING SECTION80 A, 50KA, TPN, MCCBmicroprocessorbased (O/C,S/C) RELEASE - 6 No, SpreaderLinks &Extended ROH for MCCB- 6 Nos., 63A TPN MCCB 35KA- 2 Nos. Terminal 63A 274 CE/UL Certified level transmitter:- SupplyofCE/ULcirtifiedof RadarleveltransmitterCEmarkedwith following technical parameters and Interfacing with PLC panel including mounting arrangement.Output-4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 275 CE/UL Certified level transmitter for CWR 276 CE/UL Certified level transmitter for OHT 277 CE/UL Certified Pressure transmitter:- Supply of CE/UL Certified pressure transmitter CE markd with following technical parameters and Interfacing with PLC panel includingmounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 278 CE/UL Certified Pressure transmitter for pumps 279 CE/UL Certified Pressure transmitter forCommon Header, OHT outlet etc. 280 Supply and fixing of Electro Mechanical type Chemical dosing system 0 to 6 LPH capacity on working pressure 4kg/cm2 to feed Sodium hypo chloride complete set with 100 Litre solution tank.(Competible to SCADA) 281 Earthingwithcopperearthplate600mmX600mmX3mmthick including accessories, and providing masonry enclosure with cover plate havinglockingarrangementandwateringpipeof2.7metrelongetc. with charcoal/ coke and salt as required according to latest IS:3043 Supplyingandlaying50mmX6mmG.I. stripat0.50metrebelow groundas stripearth electrode, including connection/ terminatingwith nut,bolt,spring,washeretc.asrequired.(Jointingshallbedoneby overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 282 Installation of all equipments, power wiring of Electrical equipments and commissioning of the pumping plants 283 RubbermatsforelectricalpurposeasperIS:5424-1969, plain/chequered (1mX2m) - 10mm thickness 284 Fire fighting equipments 4.5 Kg such as four nos. fire extinguishers ABC type, one set sand bucket with stand and grouting at site and one set Al strong plate and board. 285 Internal & External electrification of Pump house 286 PUMPING PLANT AND ACCESSORIES FROM CWR TO OHT AT CHUIKHADAN ( 450KL / 22M ) 287 Supply of Vertical type self-waterlubricated statically, dynamically, hydraulically balanced turbine pumpcapable of discharging at thefollowingdutyconditionasgivenbelowduetoallcauseswith surface discharge head confirming to IS:1710 and as amended as on date with accessories as per IS 5120/1977(Reconfirmed 2011) and as amendedthereaftertosuitthesitecondition.ThePumpBowlassembly and casing shall be CI IS 210 FG: 260 with suitable coating inside casing of 500 DFT, suitable for protection against corroision,erosion and prevent oxidation.Impeller and Wearing / Neckringshall be Duplex stainless steel CD4MCu (Chromium-24.5% minimum,Carbon < 0.04% ) as per ASTM A890 GrlA or DIN 1.4474-EN 10088, Hardness 220-260 BHN,pump shaft-Stainless steel AISI 410, pumps and line shaft sleeve - stainless steel with ceremic coating 700 BHN,Strainer-SS 304,coupling between pump ang motor - Flexible pin bush type and bearings shall be Anti friction L-10 with 60000 Hrs life at 1450 rpm.06mtr/suitablelengthcolumnassembly, with vertical Solid shaft Squirrel cage induction motor(IS:126152011/IEC60034-1)suitablefortheabovepump continuous rated TEFC IP-55 with Class F insulation for operation in AC, three Phase/50 HZ (±5%), 415V (±10%), running with a speed of pump. Capacity as follows :- 288 1860LPM, 30 HP, 40m Head 289 MAIN PIPING AND VALVES :-Supply of 150mm Main piping & valves complete of suitable size and quantity required for delivery side and 150mm common Header upto 1 m. outsidethe pump house along with 150 x 150 x 150 mm A/F Tee,150 mm duckfoot bend, Enlargers, 200 mm blind flange, D/F Pipes suitable sizeall necessary nuts, bolts, rubber packing, M.S Support for pipe,mechanical joints and valve etc. complete in all respect as per site conditions suitable for above pumping plants. 290 Motor operated actuator with sluice valve :- Supply of DI/DF sluice valve withElectrically integrated actuater (Totally enclosed,weather-proofanddustproofconstructionwithIP-67, protectionclass suitable for installationin any positionwithout lubrication,leakageorotheroperationaldifficultywithspecialgrease filledgearboxandsuitableformanualoperationforemergencywhich will automatically dis-engage on restoration of power to motor and with10wattsingle phase spaceheaterandcontinuouslocalmechanical positionindicatorandindividuallyreplaceablecountergearassembly and with two torque and four limit switches with S.S. flap and operated withgeardrivencamsandofrating250Volt,5Amp,AC/DC,torque switch dialand with TEFC squirrel cageinduction) operatedsuitable to SCADAoperationsluicevalvehavingbodydoorcoverof gradedincast irontoIS:210Gr.Fg.260bodyanddoorringsofSSASTMA743Gr.CF8 andbearingblockofleadedtinbronzetoIS:318Gr.LTB2hingepinof stainlesssteelAISI:431.ValvesgenerallyconformtoIS:5312.Flangesto bedrilledasperIS:1538Part-IV&VI. Valves aresuitable for hydrostatictestpressureof10Kg./Cm2 forseatand15Kg./Cm2for body(PN-1.0)of following sizes 291 Valve actuator of size 150mm for pumps 292 Valve actuator of size 150mm for common header 293 Valve actuator of size 300mm at OHT outlet 294 Non return valve :- Supply of DI/DF Single Door/ Multi Door Non return/reflux valve conforming to IS:5312/2003(partI & II) PN-1.0 to be fixed after pumps for 90% fast closing & 10% slow closing . 295 150 mm Dia for pumps 296 150 mm Dia for common header 297 CE/UL Certified Electromagnetic flow meter :- SupplyofCE/ULFullBorecElectromagneticFlowMeterofapproved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated), Pressure:upto1.0 MPa,Processtemp:-50degC, Flow/MeterTube:SS304, Electrode:SSAISI316L/ HastelloyC276/ Tantalum, Lining Material : Hard Rubber/ Neoprene/ Poly-urethane(PU), Flange: SS /CS, FlangeStandard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Càst Aluminium,with anticorrosivepaint&providecompletely sealed (leak proof) constructionasperrequirement‘ofIEC 60529, Accuracy : + 0.5 % M.V. velocity0.3to10m/s,Transmitter/signaconvertor Enclosure :Die CastAluminium, Power Supply: 80-240 V AC-5OHz,Output1: 4-20 mA,Output2:Pulse,CommunicationOutput:RS485/Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable. 298 Electromagnetic flow meter of size 150mm for common header 299 Electromagnetic flow meter of size 300mm at CWR Inlet 300 Electromagnetic flow meter of size 300mm at OHT outlet 301 ELECTRICAL ITEMS:- 302 Supply& laying of 1.1KV grade XLPE insulated unarmured multi strand copper conductor cable of 3C x 25 sq.mmfrom control Panel to respective Motors with lugs etc. (copperconductor should be electrlytic grade copper, purity >99.97% ISI marked asper IS:1554 P-I / IS :7098 P I) 303 MOTOR CONTROL CENTER (MCC) PANEL :-Single front, Indoor & floor mounted,cubical type Panel factory fabricated (2 mm thick for sructure, 1.6mm thick for door,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coateddust and vermin proof IP-54 /IS:2147, considered Earth Bus-Bar-GI Strip compitableto SCADA operation with RS485 Port consisting ofINCOMMING SECTION125A,50KA,TPN,ACB microprocessorbaseed (O/C,S/C)release-1 No , Spreader Links & Extended ROH for - 1 No, 3 Phase Digital MultifunctionMeter -1No,DigitalVoltmeter0-500V -1No,Digital Ammeter 0-400A- 1 Nos, CT For meter Resin Cast CL-1400A/5A,15VA - 3 Nos, Phase indication light LED type 220V AC - 1 Set, Control MCB SP 6A ,10KA ABB - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Link - 1 No. OUTGOING SECTION100 A, 50KA, TPN, MCCBmicroprocessorbased (O/C,S/C) RELEASE - 6 No, SpreaderLinks &Extended ROH for MCCB- 6 Nos., 63A TPN MCCB 35KA- 2 Nos. Terminal 63A 304 CE/UL Certified level transmitter for CWR :- SupplyofCE/ULcirtifiedof RadarleveltransmitterCEmarkedwith following technical parameters and Interfacing with PLC panel including mounting arrangement.Output-4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 305 CE/UL Certified level transmitter for CWR 306 CE/UL Certified level transmitter for OHT 307 CE/UL Certified Pressure transmitter:- Supply of CE/UL Certified pressure transmitter CE markd with following technical parameters and Interfacing with PLC panel includingmounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 308 CE/UL Certified Pressure transmitter for pumps 309 CE/UL Certified Pressure transmitter forCommon Header. 310 CE/UL Certified Pressure transmitter for OHT outlet 311 Supply and fixing of Electro Mechanical type Chemical dosing system 0 to 6 LPH capacity on working pressure 4kg/cm2 to feed Sodium hypo chloride complete set with 100 Litre solution tank.(Competible to SCADA) 312 Earthingwithcopperearthplate600mmX600mmX3mmthick including accessories, and providing masonry enclosure with cover plate havinglockingarrangementandwateringpipeof2.7metrelongetc. with charcoal/ coke and salt as required according to latest IS:3043 Supplyingandlaying50mmX6mmG.I. stripat0.50metrebelow groundas stripearth electrode, including connection/ terminatingwith nut,bolt,spring,washeretc.asrequired.(Jointingshallbedoneby overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 313 Installation of all equipments, power wiring of Electrical equipments and commissioning of the pumping plants 314 RubbermatsforelectricalpurposeasperIS:5424-1969, plain/chequered (1mX2m) - 10mm thickness 315 Fire fighting equipments 4.5 Kg such as four nos. fire extinguishers ABC type, one set sand bucket with stand and grouting at site and one set Al strong plate and board. 316 Internal & External electrification of CWR 317 PUMPING PLANT AND ACCESSORIES FROM CWR TO OHT AT KANSHIRAM COLONY (EXISTING) 318 Supply of Vertical type self-waterlubricated statically, dynamically, hydraulically balanced turbine pumpcapable of discharging at thefollowingdutyconditionasgivenbelowduetoallcauseswith surface discharge head confirming to IS:1710 and as amended as on date with accessories as per IS 5120/1977(Reconfirmed 2011) and as amendedthereaftertosuitthesitecondition.ThePumpBowlassembly and casing shall be CI IS 210 FG: 260 with suitable coating inside casing of 500 DFT, suitable for protection against corroision,erosion and prevent oxidation.Impeller and Wearing / Neckringshall be Duplex stainless steel CD4MCu (Chromium-24.5% minimum,Carbon < 0.04% ) as per ASTM A890 GrlA or DIN 1.4474-EN 10088, Hardness 220-260 BHN,pump shaft-Stainless steel AISI 410, pumps and line shaft sleeve - stainless steel with ceremic coating 700 BHN,Strainer-SS 304,coupling between pump ang motor - Flexible pin bush type and bearings shall be Anti friction L-10 with 60000 Hrs life at 1450 rpm.06mtr/suitablelengthcolumnassembly, with vertical Solid shaft Squirrel cage induction motor(IS:126152011/IEC60034-1)suitablefortheabovepump continuous rated TEFC IP-55 with Class F insulation for operation in AC, three Phase/50 HZ (±5%), 415V (±10%), running with a speed of pump. Capacity as follows :- 319 700LPM, 12.5 HP, 35m Head 320 MAIN PIPING AND VALVES :-Supply of 100mm Main piping & valves complete of suitable size and quantity required for delivery side and 100mm common Header upto 1 m. outsidethe pump house along with 100 x 100 x 100 mm A/F Tee,100 mm bend, Enlargers, 100 mm blind flange, D/F Pipes suitable sizeall necessary nuts, bolts, rubber packing, M.S Support for pipe,mechanical joints and valve etc. complete in all respect as per site conditions suitable for above pumping plants. 321 Motor operated actuator with sluice valve :- Supply of DI/DF sluice valve withElectrically integrated actuater (Totally enclosed,weather-proofanddustproofconstructionwithIP-67, protectionclass suitable for installationin any positionwithout lubrication,leakageorotheroperationaldifficultywithspecialgrease filledgearboxandsuitableformanualoperationforemergencywhich will automatically dis-engage on restoration of power to motor and with10wattsingle phase spaceheaterandcontinuouslocalmechanical positionindicatorandindividuallyreplaceablecountergearassembly and with two torque and four limit switches with S.S. flap and operated withgeardrivencamsandofrating250Volt,5Amp,AC/DC,torque switch dialand with TEFC squirrel cageinduction) operatedsuitable to SCADAoperationsluicevalvehavingbodydoorcoverof gradedincast irontoIS:210Gr.Fg.260bodyanddoorringsofSSASTMA743Gr.CF8 andbearingblockofleadedtinbronzetoIS:318Gr.LTB2hingepinof stainlesssteelAISI:431.ValvesgenerallyconformtoIS:5312.Flangesto bedrilledasperIS:1538Part-IV&VI. Valves aresuitable for hydrostatictestpressureof10Kg./Cm2 forseatand15Kg./Cm2for body(PN-1.0)of following sizes 322 Valve actuator of size 100mm for pumps 323 Valve actuator of size 100mm for common header 324 Valve actuator of size 250mm at OHT outlet 325 Non return valve :- Supply of DI/DF Single Door/ Multi Door Non return/reflux valve conforming to IS:5312/2003(partI & II) PN-1.0 to be fixed after pumps for 90% fast closing & 10% slow closing . 326 100 mm Dia for pumps 327 100 mm Dia for common header 328 CE/UL Certified Electromagnetic flow meter :- SupplyofCE/ULFullBorecElectromagneticFlowMeterofapproved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated), Pressure:upto1.0 MPa,Processtemp:-50degC, Flow/MeterTube:SS304, Electrode:SSAISI316L/ HastelloyC276/ Tantalum, Lining Material : Hard Rubber/ Neoprene/ Poly-urethane(PU), Flange: SS /CS, FlangeStandard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Càst Aluminium,with anticorrosivepaint&providecompletely sealed (leak proof) constructionasperrequirement‘ofIEC 60529, Accuracy : + 0.5 % M.V. velocity0.3to10m/s,Transmitter/signaconvertor Enclosure :Die CastAluminium, Power Supply: 80-240 V AC-5OHz,Output1: 4-20 mA,Output2:Pulse,CommunicationOutput:RS485/Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable. 329 Electromagnetic flow meter of size 100mm for common header 330 Electromagnetic flow meter of size 250mm at CWR Inlet 331 Electromagnetic flow meter of size 250mm at OHT outlet 332 ELECTRICAL ITEMS:- 333 Supply& laying of 1.1KV grade XLPE insulated unarmured multi strand copper conductor cable of 3C x 10 sq.mmfrom control Panel to respective Motors with lugs etc. (copperconductor should be electrlytic grade copper, purity >99.97% ISI marked asper IS:1554 P-I / IS :7098 P I) 334 MOTOR CONTROL CENTER (MCC) PANEL :-Single front, Indoor & floor mounted,cubical type Panel factory fabricated (2 mm thick for sructure, 1.6mm thick for door,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coateddust and vermin proof IP-54 /IS:2147, considered Earth Bus-Bar-GI Strip compitableto SCADA operation with RS485 Port consisting ofINCOMMING SECTION100A,50KA,TPN,ACB microprocessorbaseed (O/C,S/C)release-1 No , Spreader Links & Extended ROH for - 1 No, 3 Phase Digital MultifunctionMeter -1No,DigitalVoltmeter0-500V -1No,Digital Ammeter 0-400A- 1 Nos, CT For meter Resin Cast CL-1400A/5A,15VA - 3 Nos, Phase indication light LED type 220V AC - 1 Set, Control MCB SP 6A ,10KA ABB - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Link - 1 No. OUTGOING SECTION40 A, 50KA, TPN, MCCBmicroprocessorbased (O/C,S/C) RELEASE - 6 No, SpreaderLinks &Extended ROH for MCCB- 6 Nos., 63A TPN MCCB 35KA- 2 Nos. Terminal 63A 335 CE/UL Certified level transmitter:- SupplyofCE/ULcirtifiedof RadarleveltransmitterCEmarkedwith following technical parameters and Interfacing with PLC panel including mounting arrangement.Output-4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 336 CE/UL Certified level transmitter for CWR 337 CE/UL Certified level transmitter for OHT 338 CE/UL Certified Pressure transmitter:- Supply of CE/UL Certified pressure transmitter CE markd with following technical parameters and Interfacing with PLC panel includingmounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 339 CE/UL Certified Pressure transmitter for pumps 340 CE/UL Certified Pressure transmitter forCommon Header. 341 CE/UL Certified Pressure transmitter for OHT outlet 342 Supply and fixing of Electro Mechanical type Chemical dosing system 0 to 6 LPH capacity on working pressure 4kg/cm2 to feed Sodium hypo chloride complete set with 100 Litre solution tank.(Competible to SCADA) 343 Earthingwithcopperearthplate600mmX600mmX3mmthick including accessories, and providing masonry enclosure with cover plate havinglockingarrangementandwateringpipeof2.7metrelongetc. with charcoal/ coke and salt as required according to latest IS:3043 Supplyingandlaying50mmX6mmG.I. stripat0.50metrebelow groundas stripearth electrode, including connection/ terminatingwith nut,bolt,spring,washeretc.asrequired.(Jointingshallbedoneby overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 344 Installation of all equipments, power wiring of Electrical equipments and commissioning of the pumping plants 345 RubbermatsforelectricalpurposeasperIS:5424-1969, plain/chequered (1mX2m) - 10mm thickness 346 Fire fighting equipments 4.5 Kg such as four nos. fire extinguishers ABC type, one set sand bucket with stand and grouting at site and one set Al strong plate and board. 347 Internal & External electrification of CWR 348 INTERNAL AND EXTERNAL ELECTRIFICATION FOR WTP 349 Internal and External Electrification 350 Outdoor Lighting 351 Supply installation tesling & Commissioning of IS0 certiftedcompany made high mast lighting system (as per PLG 07 of ILP UK technical report no 7 of ILE UK /IS:875 Part-1 - 2015//BSEN10025/and IS:2062 )consisting of totally hot dip galvanised by single dipped method high mast, lantern carriage suitable for up to 12 nos luminaries with welded arm (excluding luminares), mast head frame assembly with full cover, including 1 No. LED 15 Watts aviation obstruction lights, double drum type self sustaining winch, integral power tool accesible from door with padlocking arrangement ( winch motor with control circuit) hot dipped galvanised heavy duty pipe lightening finial, S.S. ropes (AISI 316, 7 / 19 costruction), EPR insulated PCP sheathed trailing cable, including outdoor type control panel for auto on / off, reverse / forward motor operation and CC foundation of M - 25 grade complete as required as per IS 456/IS 2911. The mast is constructed from mild steel plates (as per IS 5986 Gr. 510 ) cut and folded to form a polygonal (Octogonal) section, telescopic jointed and welding as per BS 5135 and also provide test certificate for wind tunnel test for High mast fixtures. complete in all respect. 352 12.5 Mtr. HM (in 2 Section) 353 Providing & Fixing of IK07 IP-66 protected high power LED flood light system with Pressure diecast aluminium housing LM6/ ADC12 material, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, 240 volt, 50Hz, of high power LED lamps . Integrated driver must be potted & has a unique BIS R number shall be high efficiency having efficiency more than 85 % and in compliance to BIS certified and T.C. certificate. The System level Luminaire efficacy >=120 Im/ wt with High Power LEDs is to be used . LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety . Input Frequency 50Hz‡3%, Power Factor >0.95 ,driver Efficiency >85% .THD(I) <10% , driver current <1000mA shown in LM79 report. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector Must be provided, Surge Protection Min >=4KV internal and 10KV external, System life of 30000 Burning hours with 70% of Initial Lumens maintained, color Rendering Index >70 and CCT 5700K + 1355K, Driver current <1000mA shown in LM79 report. Manufactures Word Mark/Name Engraved/Embossing/Screenprinting on die cast housing to allow traceability/authenticity. Fixture-shall be IS 10322 Complianced and also provide test Certificate/ report with liable warranty of product/accessories. 354 High Power LED Flood Light 200W 355 Indoor Lighting 356 Providing & Fixing of IP40 LED Surface/ Recessed / suspended mounting Mid power SMD type LED Light fixture made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with2.5 KV internal/external surge protection B|S certified isolated driver having efficiency > 85% , with Short & Open circuit protection and in compliance to IC standards (Integral with light fixture). System lumen efficacy of ≥ 120 Im/Watt ,THD < 10 % , p.f.>0.95,CRI >80 . life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K / 16000°K / 6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing and also provide test certificate of LED Fixtures from NABL. 357 36 W LED light Fixture 2 x 2 with acrylic / prismatic front cover. 358 Complete wiring of Pump house, HT & LT room with 1.5 sqmm and 2.5 sqmm with multistarned copper conductor 1.1 KV with required 6A,16A switches,sockets,MCCB etc. 359 Automation For Intake Well 360 CE & UL Certified PLC/RTU with redudant CPU & Power supply in IP 54 enclosure suitable to Communicate with GSM based modem unit with redudant CPU & Power Supply with analog & digital parameter & features as specified for each ZPS/OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations with control panel as specified in tender technical specification. 361 GSM / GPRS based wireless communication with 4G modem for RTU/PLC Capable to transfer & gather data from remote sites to control stations all accessories including with signal enhancer antanna made for pumping plant internet charges as specified in tender technical specification. 362 CE/UL Certified Intelligent energy meters 363 CE/UL Certified Surge protector for control panel 364 CE/UL Certified 7 touch screen suitable for communication with PLC/RTU for local display & control of process parameters. 365 Cable 366 (i) Complete cabling above 3 Pumps 367 Security Survelliance IP Camera with recorder (optional) 368 Installation, commissioning & testing 369 AUTOMATION FOR CWR-1A 370 CE & UL Certified PLC/RTU with redudant CPU & Power supply in IP 54 enclosure suitable to Communicate with GSM based modem unit with redudant CPU & Power Supply with analog & digital parameter & features as specified for each ZPS/OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations with control panel as specified in tender technical specification. 371 GSM / GPRS based wireless communication with 4G modem for RTU/PLC Capable to transfer & gather data from remote sites to control stations all accessories including with signal enhancer antanna made for pumping plant internet charges as specified in tender technical specification. 372 CE/UL Certified Intelligent energy meters 373 CE/UL Certified Surge protector for control panel 374 CE/UL Certified 7 touch screen suitable for communication with PLC/RTU for local display & control of process parameters. 375 Turbidity Analyzer at CWR 376 PH Analyzer 377 Chlorine Analyzer 378 Cable 379 (i) Complete cabling upto 3 Pumps 380 Security Survelliance IP Camera with recorder (optional) 381 Installation, commissioning & testing 382 AUTOMATION FOR CWR-1B 383 CE & UL Certified PLC/RTU with redudant CPU & Power supply in IP 54 enclosure suitable to Communicate with GSM based modem unit with redudant CPU & Power Supply with analog & digital parameter & features as specified for each ZPS/OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations with control panel as specified in tender technical specification. 384 GSM / GPRS based wireless communication with 4G modem for RTU/PLC Capable to transfer & gather data from remote sites to control stations all accessories including with signal enhancer antanna made for pumping plant internet charges as specified in tender technical specification. 385 CE/UL Certified Intelligent energy meters 386 CE/UL Certified Surge protector for control panel 387 CE/UL Certified 7 touch screen suitable for communication with PLC/RTU for local display & control of process parameters. 388 Turbidity Analyzer at CWR 389 PH Analyzer 390 Chlorine Analyzer 391 Cable 392 (i) Complete cabling upto 3 Pumps 393 Security Survelliance IP Camera with recorder (optional) 394 Installation, commissioning & testing 395 AUTOMATION FOR CWR-2A 396 CE & UL Certified PLC/RTU with redudant CPU & Power supply in IP 54 enclosure suitable to Communicate with GSM based modem unit with redudant CPU & Power Supply with analog & digital parameter & features as specified for each ZPS/OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations with control panel as specified in tender technical specification. 397 GSM / GPRS based wireless communication with 4G modem for RTU/PLC Capable to transfer & gather data from remote sites to control stations all accessories including with signal enhancer antanna made for pumping plant internet charges as specified in tender technical specification. 398 CE/UL Certified Intelligent energy meters 399 CE/UL Certified Surge protector for control panel 400 CE/UL Certified 7 touch screen suitable for communication with PLC/RTU for local display & control of process parameters. 401 Turbidity Analyzer at CWR 402 PH Analyzer 403 Chlorine Analyzer 404 Cable 405 (i) Complete cabling upto 3 Pumps 406 Security Survelliance IP Camera with recorder (optional) 407 Installation, commissioning & testing 408 AUTOMATION FOR CWR-2B 409 CE & UL Certified PLC/RTU with redudant CPU & Power supply in IP 54 enclosure suitable to Communicate with GSM based modem unit with redudant CPU & Power Supply with analog & digital parameter & features as specified for each ZPS/OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations with control panel as specified in tender technical specification. 410 GSM / GPRS based wireless communication with 4G modem for RTU/PLC Capable to transfer & gather data from remote sites to control stations all accessories including with signal enhancer antanna made for pumping plant internet charges as specified in tender technical specification. 411 CE/UL Certified Intelligent energy meters 412 CE/UL Certified Surge protector for control panel 413 CE/UL Certified 7 touch screen suitable for communication with PLC/RTU for local display & control of process parameters. 414 Turbidity Analyzer at CWR 415 PH Analyzer 416 Chlorine Analyzer 417 Cable 418 (i) Complete cabling upto 3 Pumps 419 Security Survelliance IP Camera with recorder (optional) 420 Installation, commissioning & testing 421 AUTOMATION FOR CWR-2C 422 CE & UL Certified PLC/RTU with redudant CPU & Power supply in IP 54 enclosure suitable to Communicate with GSM based modem unit with redudant CPU & Power Supply with analog & digital parameter & features as specified for each ZPS/OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations with control panel as specified in tender technical specification. 423 GSM / GPRS based wireless communication with 4G modem for RTU/PLC Capable to transfer & gather data from remote sites to control stations all accessories including with signal enhancer antanna made for pumping plant internet charges as specified in tender technical specification. 424 CE/UL Certified Intelligent energy meters 425 CE/UL Certified Surge protector for control panel 426 CE/UL Certified 7 touch screen suitable for communication with PLC/RTU for local display & control of process parameters. 427 Turbidity Analyzer at CWR 428 PH Analyzer 429 Chlorine Analyzer 430 Cable 431 (i) Complete cabling upto 3 Pumps 432 Security Survelliance IP Camera with recorder (optional) 433 Installation, commissioning & testing 434 AUTOMATION FOR CWR-2D 435 CE & UL Certified PLC/RTU with redudant CPU & Power supply in IP 54 enclosure suitable to Communicate with GSM based modem unit with redudant CPU & Power Supply with analog & digital parameter & features as specified for each ZPS/OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations with control panel as specified in tender technical specification. 436 GSM / GPRS based wireless communication with 4G modem for RTU/PLC Capable to transfer & gather data from remote sites to control stations all accessories including with signal enhancer antanna made for pumping plant internet charges as specified in tender technical specification. 437 CE/UL Certified Intelligent energy meters 438 CE/UL Certified Surge protector for control panel 439 CE/UL Certified 7 touch screen suitable for communication with PLC/RTU for local display & control of process parameters. 440 Turbidity Analyzer at CWR 441 PH Analyzer 442 Chlorine Analyzer 443 Cable 444 (i) Complete cabling upto 3 Pumps 445 Security Survelliance IP Camera with recorder (optional) 446 Installation, commissioning & testing 447 Local Control Station at WTP 448 CE/UL & BIS Certified industrial grade LED Monitor with latest configuration as per specification 449 Desktop / PC with i5/i7 processor for as per technical bid documents 450 CE/UL Certified 3 KVA UPS with batteries as per technical bid documents 451 Full development version of required TAGS SCADA Software with customization of software for LCS as per requirement as per spec. mentioned in technical bid documents. 452 CE/UL certified local control room PLC with redundant CPU & power supply at LCS in IP 54 enclouseras per spec. mentioned in technical bid documents. 453 GSM based wireless/Broadband/Equivalent communication system for PLC capable to transfer & received data & gather from remote sites to control station, all accessories included signal enhancer anternna along with running expenses till DLP 454 CE/UL Certified firewall for network protection 455 SURGE PROTECTOR FOR ETHERNET communication protection. 456 CE/UL certified industrial grade Ethernet Swtich 457 Cannon/HP or equivalent Laser printer 1018 or equivalent 458 Security Survillance IP Camera with recorder (Optional) 459 Installation, Commissioning & testing including required furniture, A/C etc. 460 Trial & Run 461 03 Months trial & run
Contract Date : Ref. Documents   |   Contract Value : Ref. Documents
BRR : 10087564 Supply, Delivery, Installation, Commissioning And Trial Operation Of Electro-Mechanical Components Of Augmentation Of Araidanga Water Supply Scheme ( Zone-I ) Tw No Iv And External Illumination Works At Head Works Site ( Zone-I And Ii ) ( Tsm / 008180 ) -1 Supply And Delivery At Site Of Following Pumping Machinery And Electrical Accrssories: 2 Submersible Pump Directly Coupled With Water Proof Suitable Size Motor Having Following Specification And As Per Nit Specification:Pumpdischarge Of Clear Water = ( Q ) = 50 M3 / Hr.Total Head ( H ) = 60 M.Hp-17.5Hpshaft- Stainless Steelimpeller- S.S / Gmoutlet Size-80 Mmmotorsubmersible Type 3 Phase, 50 Hz, 415V ± 10% , 2900 Rpmmotor Mustbe Suitable For Operation With Star-Delta Starter Test Certificate Along With Characteristic Curve Shoule Besubmitted At The Time Of Delivery. ) 3 1.1 Kv Grade 6 Sqmm X 3 Core Water Proofflat Submersible Cable For Above Motor. 4 1.1 Kv Grade 25 Sqmm 3.5 Core Xlpe Insulated Al. Ar. Cable Conforming To Is-7098 ( Part-1 ) 1988 With Upto Date Amendment. 5 Supply, Delivery And Storage At Site Of Wall Mounted 2 Mm. Thick Epoxy Painted Sheet Steel Enclosed Front Open Fully Panel For Fully Automatic Cum Manual Control Centre For Operation Of The Pump Motor In Star-Delta Mode Ranging From 15 Hp To 25.Hp Actuator With Dol Starter, Chlorinator With Dol Starter And Timer Operated Outdoor And Indoor Lighting And Also Spares Feeder As Per Approved Drawingand Nit Specification. ) 6 Supply And Delivery Of The Following Valves, Pipes, Gauges Etc. At Site. 7 80 Mm Dia M.S. Seamless Column Pipe ( Black ) 6.8 Mm To 7.1 Mm Thick With 150 Mm Long Heavy Type Socket At One End. 8 3.00 Mtr. Long Excluding Socket Having 8 T.P.I. Thread. 9 1.5 Mtr. Long Excluding Socket One End Having A Thread Of 11 T.P.I. & The Other End Having A Thread Of 8 T.P.I. 10 Cast Iron Wafer Type Three Phase Multi-Turn Actuator Operated Butterfly Valve Of Dia 80Mm ( P.N-1.0 ) As Per ( Is-13095 Ip-68 ) Test Certificates From Both The Manufacturer Are To Be Submitted At The Time Of Delivery 11 80Mm Dia Cidf Sluice Valve-1 No., Non Return Valve-1 No., Cidf 90° Bend-1No., Ci Flanged Tee-1No. Blank Flange-1No., Ci / Ms Flanged Short Piece 0.50 Mtr.-2 Nos, Ci / Ms Flanged Pipe 1 Mtr.-2 Nos. 1 No. Suitable Ms Enlarger With Ms Nipple For 80 Mm Dia Outlet If Required Etc As Per Is Specification And Certification For Construction Of Delivery Pipe Line And Wash Out Line. 12 Heavy Type 250 Mm Dia Split Type Tube Well Cover With 12 Mm Thick Clamping Arrangement Including Holes Of Column Pipe, Air Pipe And Cable Entry With 2 Sets Heavy Type Suspension Clump, Nuts, Bolts And Washer As Per Departmental Design. 13 Depth Gauge 100Mm Dia With Steel Air Pipe Of Required Length With All Accessories For The Above Work Including Supply Of Good Quality Hand Pump. ( This Cost Includes 15 Mm. Dia G.I. Pipes And Specials ) 14 Pressure Gauge ( H.Guru / Febig ) 150Mm Dia ( 0-7Kg / Sq.Cm ) Brass Cock And Fitting Complete. ( This Cost Includes 15 Mm. Dia G.I. Pipes And Specials ) 15 50 Mm. Dia. Non Metalic Pipes ( Is:14930 ) And Specials For Protection Of Submersible Cable ( As Per Site Requirement ) 16 Anti Snapping Safety Device For Pump Set By Supplying Suitable Size Ms Clamps Two Sets And Nylon Rope Of Required Length Including Supplying Of Nuts, Bolts And All Other Materials. 17 100 Amps 415Vporcelain Based Rewireable Type Male-Female Kit-Kat Fuse Unit. 18 100 Amp 415 V Rewireable Type Tpn Main Switch. 19 Laying Of 25 Sq. Mm. 3.5 Core Al. Ar. Cable In Wall / Floor By Supplying Of All Necessary Materials As Per Ie Rules And As Per Direction 20 Installation Of The Materials ( To Be Supplied Under Above Sl No 1.01 To 3.10 ) Such As Pump Motor Set With Column Pipes, Valves, Panel, Fiting Fixing Pressure Gauge, Depth Gauge, Non-Return Valve & Drawing Delivery Out-Let & Washout Line With The Supplied Specials / Accessories By Providing Antisnapping Cage Of Suitable Size Including Supply Of Cable Gland, Sockets, Hard Wooden Board ( 750Mm X 450Mm ) . Etc Including Brick, Sand, Cement Rod Etc As Required To Complete The Job As Per Direction And Up To The Entire Satisfaction Of The Eic. 21 Making Brick Pillar 0.25 Mtr X 0.25 Mtr. For Supporting Of Valves And Pipes With 12 Mm Thick Plaster And Net Cement Finish Complete. 22 Supply, Delivery Of M.S Kiosk Box Of 661Mm X 559 Mm ( Lxw ) Size Having Thickness Of 1.5 Mm With Angle Support At Four Legs Having Hight Of 661 Mm With Provision Of Locking Arrangement, Supply Of Lock, Cable Entry Point Incl Painting By One Coat Of Black Paint Over One Coat Of Primer All Complete. 23 Making Suitable Size Pump Foundation Including Erection Of Kiosk Box With Supplying Of Necessary Cement, Sand And Stone Chips Including Plastering And Net Cement Finish Complete. 24 Making Double Earthing Arrangement In Compliance With Ie Rules By G.I. Pipe Electrode Of 50 Mm. Dia 3 Mtr. Long 2 Nos For Panel And Pumping Machinery 25 Mm. X 6 Mm. G.I. Earth Strips From Earth Pit To Panel And All Other Accessories Required To Complete The Work. 25 Making Internal Electrification Of Pump House Consisting Of Two Bracket Point, One Tube Light Point, Two Bulk Head Point, One Fan Point And 1 No. 74 Watt Led Fixture With Arm Bracket At Outside And One Three Pin Plug Point Including Supply Of All Necessary Materials To Complete The Work As Per Ie Rules And As Per Direction ( All The Fittings And Lamp Should Be Led Type As Per Choice Of Eic ) 26 Supply And Delivery Ofpvc Moulded Chair. 27 Supply And Delivery Of Pvc Moulded Table. 28 Supply, Delivery & Installation Of The Following Fan As Directed By Eic.Ceiling Fan 1200Mm Sweep Including Fan Clamp As And When Required. 29 Supply And Delivery At Site Of30 Kva3 Phase Oil Cooledtype Servo Motor Operated Copper Wound Line Voltage Corrector Conforming To Is-9815 ( Pt.-1 ) -1994 Suitable For Un-Balanced Input Voltage Phase To Phase 200 V - 500 V Including First Filling Oil As Per Is-335 Where Applicable As Per Approved Drawingand Nit Specification. ) 30 Supply And Delivery Of Following Materials At Site: 31 100 Amps, 415 V, 4 Pole On Load Change Over Switch. 32 100 Amps, 415 V Tpn Rewireable Type Mainswitch. 33 100 Amps Bus-Bar Chamber Having 4 Nos. Al. Bus-Bar. 34 1.1 Kv Grade 415 V, 25 Sqmm, 3.5 Core Pvc Insulated 1.1 Kvaluminiumarmoured Cable. 35 Making Brick Built Foundation With Supplying Of All Required Materials Suitable For The Above Voltage Stabilizer By ( 4:1 ) Cement Mortar Including Holding Down Foundation Bolts And 12 Mm Thick Plaster With Neat Cement Finish, Sloping All Complete As Per Direction Of Eic. 36 Fitting , Fixing Of Change Over Switch, Busbar Chamber And Main Switch As Mentioned In Item No. 14.01, 14.02 And 14.03 On The Iron Angle Frame Of Suitable Size Fixed At Suitable Position On Wall By Supplying All Necessary Fixing Materials All Complete As Per Direction Of Eic. 37 Installation Of The Above Voltage Stabilizer As In Item No.13.00 On The Foundation Including Making All Connection Complete As Per Direction. 38 Drawing And Connection Of Cable As In Item No. 15.04 On Wall / Surface From Change Over To Panel Via Voltage Stabilizer, Bus Bar And Main Switch Incl. S & Fitting-Fixing Of Required Nos. Of Ms Saddles With Earthing Attachment In 10 Swg Gi ( Hot Dip ) Wire, Making Holes Etc. As Necy. Mending Good Damages And Painting. 39 Making Joints Of The Cable By Supplying Compresion Type Gland Thimple, Socket Etc. As Per Requirement And As Per Direction Of Eic. 40 Double Earthing The Whole Installations Complying With Ir Rules Including Supplying Of All Necessary Earthing Materilas For Voltage Corrector Device To Complete The Job As Per Direction Of Eic. 41 Supply & Delivery Of Automatically Controlleddiaphargm Type Chlorinator For Accurate Dosing Of Chlorine Solution Into The Waterby Connecting Metering Pump ( Diaphargm Type ) Having Following Specification:- Pump Type ::Diaphargmliquid ::Chlorine Solutioncapacity ( Lph ) :: 0-100Pressure Kg / Cm2 ( Testing ) :: 10Pressure Kg / Cm2 ( Suction ) :: Floodedpressure Kg / Cm2 ( Hydro ) :: 15Connection Suction :: ½” Hose Holderconnection Discharge :: ½: Hose Holdermoc Liquid End :: Ppdiaphragm :: Ptfenrv :: Ppdrive Capacity :: 0.5Hp, 3 Phase, 50Hz, 415V, 1440 Rpmmotorcoupling Capacity :: Flexible Spiderstrainer :: Y Type, Pp, ½” Bsp ( F ) Pressure Relief Valve :: Inbuilt.Solution Tank :: 100 Ltr Capacity ( Including Making Provision For Inlet Line To The Actual Storage Tank Of Dosing Solution Of All Materials. Test & Warrantycertificatesare To Be Submitted At The Time Of Delivery 42 Installation Of Above Supplied Chlorinator With All Accessories, Pvc Tankand Drawing Of Power Line As Per Ie Rules By Supplying Pvccopper Wire & Continuous Earthing. This Includes The Cost Of All Necessary Cc Foundation ( At Least 200Mm Height ) With Concrete Mixture ( Sand, Cement, Stone ) And Neat Cement Finish By Supplying Of All Required Materials And Testing The Entire Set As Perentire Satisfaction Of The Eic. ( Power Will Be Fed From Plc Panel Of Pumping Machinery ) 43 Commissioning Of The Installation With Full Satisfaction Of Eic. 44 Trial Run As Per Departmental Operation & Guarding By Engaging Skilled Staff For 1 Month. 45 For Araidanga Zone -I Head Works Site 46 Supply & Delivery At Site Of 9Mtrs Long Steel Tabular Pole With Sole Plate As Per Direction Of Eic ( Designation- 410 Sp-26. ( Over All Length-9.00Mtr, Planting Depth- 1.5Mtr, Length Of Section ) ( Bottom-5.0Mtr, Middle- 2.0Mtr, Top- 2.0Mtr, ) Outside Dia & Thickness Of Section ( Bottom-114.3X4.50Mm, Middle-88.9X4.05Mm, Top-76.1X3.25 ) Approx Weight Of Pole-92Kg ) 47 Erection Of 9 Mtr Single Steel Tubular Pole Of Length As Given Below With Sole Plate & Cap Etc. In Cc Foundation ( Proportion And Dimension Indicated Below ) , Having 600X600x750 Mm Thick Cc ( 4:2:1 ) Base Block Below Sole Plate / Pole With Hard Jhama Metal Including Cc ( 6:3:1 ) Base Block ( Around The Pole ) Dimension 0.60X0.60X0.50 Mt. Above Ground Level Including 2 Mm Thick Neat Cemented Finish And Gi Earth Bolt And Earthing Arrangement By 8Swg Gi Wire, After Making Drilled Holes Etc. On Pole Including Filling Up The Excavated Earth Pit With Shifted Soil And Ramming Properly. 48 Supply & Fixing 1.5 Mtr Long Hot Dip Galvanised Single Arm Bracket ( Removeable Type ) Fabricated With 48.3Mm Dia 3.25Mm Thick Gi Pipe Which Should Be Duly Welded With Angle Support Stiffener And Single Standard Arm Cap Made Of 300Mm Long Gi Pipe Of Dia Suitable For Existing Tubular Pole And Should Be Equipped With Necessary 2 Nos Bolts For Tightening The Single Arm Bracket With Existing Pole Structure As Per Direction Of Eic. 49 Supply & Laying Of 1.1 Kv Gr. 2 Core 6 Sq.Mm Xlpe Armored Alu. Cable ( Approved Make ) On Wall / Surface Incl. S & F Ms Saddles With Earthing Attachment In 10 Swg Gi ( Hot Dip ) Wire, Making Holes Etc. As Necy. Mending Good Damages And Painting As Directed By Eic. 50 Supply & Laying Of 1.1 Kv Gr. 2 Core 6 Sq.Mm Xlpe Armored Alu. Cable In Underground Trench 460 Mm Wide X 760 Mm Average Depth, With Brick Protection Onthe Top Of The Cable With 8 ( Eight ) Nos. Bricks Per Metre, Including Filling The Space Between The Brick & Cable And Also The Trench With Shifted Soil, Leveling Up And Restoring Surface Duly Rammed. 51 Supplying And Fixing 2+4 Way Spmcb With 40A Dp Isolator-1No & 6-32 Amp-3-Nos240 / 415 V Mcb Of Breaking Capacity 10Ka & B Characteristics With Mcb Enclosure And Necessary Connection As Per Direction Of Eic. ( Approved Make ) 52 Supplying And Fixing Compression Type Gland Complete With Brass Gland, Brass Ring & Rubber Ring For Dust & Moisture-Proof Entry 1.1 Kv Gr. 2 Core 6 Sq.Mm Xlpe Armored Alu. Cable Incl. Finishing The End Of The Same By Crimping Method Incl. Supplying And Fixing Solderless Socket ( Dowels Make ) , Tapes, Anticorrosive Paste & Jointing Materials As Per Direction Of Eic. 53 Supplying And Drawing 1.1 Kv Single Core Stranded Fr Pvc Insulated & Unsheathed Single Core Stranded Copper Wire Of 3 X 22 / 0.3 ( 1.5 Sqmm ) ( Approved Make ) Through Gi Pipe And Making Necy. Connection As Required As Per Direction Of The E.I.C ( From Pole Loop Box To Led Fittings ) . 54 Supplying And Fixing 250 X 250 X 100Mm Gi Water Proof Looping Cable Box Having Hinged Gi Top Cover Having 4 Mm Thick With Rubber Gasket Lining, Railway Type Mechanical Locking Arrangement With Required Gi Pipe For Cable Laying From Ground To Loop Box, Earthing Terminal With Lug Etc. Of The Following Sizes As Indicated Below, Comprising Of One 250 V, 6A Spmcb Unit, One Nl On Porcelain Insulator Etc. And Housing The Same In Pole Muffing Incl. Painting As Directed By Eic. 55 Supplyand Fixing Of Street Light Luminarie Ip 66 Lm6-Hpdc Housing Street Light Aerodynamically Designed With Better Thermal Management / Potted Driver Is To Be Provided, The Luminaire And Housing Should Be From The Same Manufacturer ( Cat No-Brp 062 Led 84 Cw Slc S1 Psu ) Make-Philips Or Equivalent And Same Techinal Specification . 56 S / Fixing Of Die Cast Aluminium Housing Of Gate Light 1X40watt Led Outdoor Luminiare ( Make-Havells- Rubypt35wled757psymtopc / Coralpt35wled757psymtopc ) Milky White Decorative Post Top For 360° Indirect Light. Ip 65 Protection Resistant To Impactb With Suitable Net Protectionand Corrosion As Per Direction Of Eic. 57 Supply , Delivery, Fitting Fixing Of Nomenclature Made From Improted Acrylic Sheet Letter Of Different Sizes With Different Colours Asper Choice Of Eic.The Subect Matter As Directed By Eic Shall Be Fixed On Iron Structure Of Size ( 10 X 4 ) And Should Be Fitted On Ms Angle ( Size - 65 Mm X 65 Mm X 6 Mm ) And Ismc 100 With Epoxy Coated Including All Necessary Civil Work After Grountig The Ms Frameon The Roof Of The Buildung And Making Necessary Pillers, Plasters, Neat Cement Finissing Etc To Complete The Work As Per Direction Of Eic Including Supplying All Required Electrical Materials. Colour Type And Colour Letter& Graphics Will Be As Per Direction Of Eic. 58 Painting All The Single Arm G.I Brackets, Poles, Pipes Etc. With 2 Coats Of Synthetic Enamel Paint Over 1 Coat Of Red Oxide Primer After Cleaning And Preparation Of Surface By Emery Paper All Complete As Per Direction. 59 For Araidanga Zone -Ii Head Works Site 60 Supply & Delivery At Site Of 9Mtrs Long Steel Tabular Pole With Sole Plate As Per Direction Of Eic ( Designation- 410 Sp-26. ( Over All Length-9.00Mtr, Planting Depth- 1.5Mtr, Length Of Section ) ( Bottom-5.0Mtr, Middle- 2.0Mtr, Top- 2.0Mtr, ) Outside Dia & Thickness Of Section ( Bottom-114.3X4.50Mm, Middle-88.9X4.05Mm, Top-76.1X3.25 ) Approx Weight Of Pole-92Kg ) 61 Erection Of 9 Mtr Single Steel Tubular Pole Of Length As Given Below With Sole Plate & Cap Etc. In Cc Foundation ( Proportion And Dimension Indicated Below ) , Having 600X600x750 Mm Thick Cc ( 4:2:1 ) Base Block Below Sole Plate / Pole With Hard Jhama Metal Including Cc ( 6:3:1 ) Base Block ( Around The Pole ) Dimension 0.60X0.60X0.50 Mt. Above Ground Level Including 2 Mm Thick Neat Cemented Finish And Gi Earth Bolt And Earthing Arrangement By 8Swg Gi Wire, After Making Drilled Holes Etc. On Pole Including Filling Up The Excavated Earth Pit With Shifted Soil And Ramming Properly. 62 Supply & Fixing 1.5 Mtr Long Hot Dip Galvanised Single Arm Bracket ( Removeable Type ) Fabricated With 48.3Mm Dia 3.25Mm Thick Gi Pipe Which Should Be Duly Welded With Angle Support Stiffener And Single Standard Arm Cap Made Of 300Mm Long Gi Pipe Of Dia Suitable For Existing Tubular Pole And Should Be Equipped With Necessary 2 Nos Bolts For Tightening The Single Arm Bracket With Existing Pole Structure As Per Direction Of Eic. 63 Supply & Laying Of 1.1 Kv Gr. 2 Core 6 Sq.Mm Xlpe Armored Alu. Cable ( Approved Make ) On Wall / Surface Incl. S & F Ms Saddles With Earthing Attachment In 10 Swg Gi ( Hot Dip ) Wire, Making Holes Etc. As Necy. Mending Good Damages And Painting As Directed By Eic. 64 Supply & Laying Of 1.1 Kv Gr. 2 Core 6 Sq.Mm Xlpe Armored Alu. Cable In Underground Trench 460 Mm Wide X 760 Mm Average Depth, With Brick Protection Onthe Top Of The Cable With 8 ( Eight ) Nos. Bricks Per Metre, Including Filling The Space Between The Brick & Cable And Also The Trench With Shifted Soil, Leveling Up And Restoring Surface Duly Rammed. 65 Supplying And Fixing 2+4 Way Spmcb With 40A Dp Isolator-1No & 6-32 Amp-3-Nos240 / 415 V Mcb Of Breaking Capacity 10Ka & B Characteristics With Mcb Enclosure And Necessary Connection As Per Direction Of Eic. ( Approved Make ) 66 Supplying And Fixing Compression Type Gland Complete With Brass Gland, Brass Ring & Rubber Ring For Dust & Moisture-Proof Entry 1.1 Kv Gr. 2 Core 6 Sq.Mm Xlpe Armored Alu. Cable Incl. Finishing The End Of The Same By Crimping Method Incl. Supplying And Fixing Solderless Socket ( Dowels Make ) , Tapes, Anticorrosive Paste & Jointing Materials As Per Direction Of Eic. 67 Supplying And Drawing 1.1 Kv Single Core Stranded Fr Pvc Insulated & Unsheathed Single Core Stranded Copper Wire Of 3 X 22 / 0.3 ( 1.5 Sqmm ) ( Approved Make ) Through Gi Pipe And Making Necy. Connection As Required As Per Direction Of The E.I.C ( From Pole Loop Box To Led Fittings ) . 68 Supplying And Fixing 250 X 250 X 100Mm Gi Water Proof Looping Cable Box Having Hinged Gi Top Cover Having 4 Mm Thick With Rubber Gasket Lining, Railway Type Mechanical Locking Arrangement With Required Gi Pipe For Cable Laying From Ground To Loop Box, Earthing Terminal With Lug Etc. Of The Following Sizes As Indicated Below, Comprising Of One 250 V, 6A Spmcb Unit, One Nl On Porcelain Insulator Etc. And Housing The Same In Pole Muffingincl. Painting As Directed By Eic. 69 Supplyand Fixing Of Street Light Luminarie Ip 66 Lm6-Hpdc Housing Street Light Aerodynamically Designed With Better Thermal Management / Potted Driver Is To Be Provided, The Luminaire And Housing Should Be From The Same Manufacturer ( Cat No-Brp 062 Led 84 Cw Slc S1 Psu ) Make-Philips Or Equivalent And Same Techinal Specification . 70 S / Fixing Of Die Cast Aluminium Housing Of Gate Light 1X40watt Led Outdoor Luminiare ( Make-Havells- Rubypt35wled757psymtopc / Coralpt35wled757psymtopc ) Milky White Decorative Post Top For 360° Indirect Light. Ip 65 Protection Resistant To Impactb With Suitable Net Protectionand Corrosion As Per Direction Of Eic. 71 Supply , Delivery, Fitting Fixing Of Nomenclature Made From Improted Acrylic Sheet Letter Of Different Sizes With Different Colours Asper Choice Of Eic.The Subect Matter As Directed By Eic Shall Be Fixed On Iron Structure Of Size ( 10 X 4 ) And Should Be Fitted On Ms Angle ( Size - 65 Mm X 65 Mm X 6 Mm ) And Ismc 100 With Epoxy Coated Including All Necessary Civil Work After Grountig The Ms Frameon The Roof Of The Buildung And Making Necessary Pillers, Plasters, Neat Cement Finissing Etc To Complete The Work As Per Direction Of Eic Including Supplying All Required Electrical Materials. Colour Type And Colour Letter& Graphics Will Be As Per Direction Of Eic. 72 Painting All The Single Arm G.I Brackets, Poles, Pipes Etc. With 2 Coats Of Synthetic Enamel Paint Over 1 Coat Of Red Oxide Primer After Cleaning And Preparation Of Surface By Emery Paper All Complete As Per Direction. 73 Make As Per Departmental Approved Vendor List Circulated Vide Memo No.Phe / Iv / 2277 / W-181 / 19 Dated- 25 / 09 / 2019 74 N.B. Progressive Bills Shall Only Be Done After Third Party Inspection Agency Engaged By Phed.
Contract Date : Ref. Documents   |   Contract Value : Ref. Documents
BRR : 3672157 Provision Of Certain Special Items For Maritime Acquatic Water Training Facility And Other Allied Structures At Icgs Okha-14 Internal Electric Supply Ns & F 20 W Surface / Wall Mounted Led Batten Having High Efficiency Long Life Led Chips With Luminous Efficacy Of > 100 Lumen / W, Independent Isolated Smps Based Constant Current Electronic Led Driver With Thd < 20%, Surge Voltage Protection And Other Safety Tests As Per Is: 15885 ( Part-2 / Sec-13 ) : 2012, Polycarbonate Diffuser, Housed In Powder Coated White Extruded Aluminium Channel Housing And White Coloured Abs End Caps Having Input Voltage 220- 240 V, Input Frequency 50- 60 Hz, Pf > 0.95, Including Electrical Connection With 3 Core Flexible Cu Conductor Cable Of Appropriate Size From Ceiling Rose To The Fixture Complete All As Specified And Directed. Nmake: Bajaj Cat-Part No. 112785 Bclab 20W Or Equivalent Model Of Havells, Philips Or Wipro 15 S & F 10 W Surface / Wall Mounted Led Batten Having High Efficiency Long Life Led Chips With Luminous Efficacy Of > 100 Lumen / W, Independent Isolated Smps Based Constant Current Electronic Led Driver With Thd < 20%, Surge Voltage Protection And Other Safety Tests As Per Is: 15885 ( Part-2 / Sec-13 ) : 2012, Polycarbonate Diffuser, Housed In Powder Coated White Extruded Aluminium Channel Housing And White Coloured Abs End Caps Having Input Voltage 220- 240 V, Input Frequency 50- 60 Hz, Pf > 0.95, Including Electrical Connection With 3 Core Flexible Cu Conductor Cable Of Appropriate Size From Ceiling Rose To The Fixture Complete All As Specified And Directed. Nmake: Bajaj Cat-Part No. 112407 Bclsb 10 Wh Or Equivalent Model Of Havells, Philips Or Wipro 16 S & F 20 W Led Street Light Having High Efficiency Long Life Led Module With Smd Led Package Mounted On Mcpcb With High Led Efficacy Of = 100 Lumen / W, Integral Smps Based Constant Current Electronic Led Driver With Thd < 20%, Surge Voltage Protection And Other Safety Tests As Per Is: 15885 ( Part-2 / Sec-13 ) : 2012, Ip 66 Protection, High Effiency Polycarbonate Cover With Integrated Lens Housed In Pressure Die-Cast Aluminium Alloy Heat Sink For Effective Thermal Management, Sturdiness, Excellent Corrosion Resistance, Separate Optical And Control Gear Compartment & Top Opening For Easy Maintenance, Suitable For Side Entry, Pole / Wall Mounted With Bracket 1.5 M Long With Including Necessary Electrical Connection To The Fixture With 3 Core Flexible Cu Conductor Cable Of Appropriate Size And Light Grade Gi Pipe, Including Gi Clamps, Nuts, Bolts & Washers With Two Coats Of Synthetic Enemal Paint Over A Coat Of Red Oxide Primer Complete All As Specified And Directed. Nmake: Bajaj Cat-Part No. Bajaj 169829 Bclst 20W Led I Or Equivalent Model Of Havells, Philips Or Wipro 17 S & F Bldc Five Star Rated Energy Efficient High-Speed Ceiling Fan Having 1200 Mm Blade Sweep, Air-Flow Not Less Than 210 Cmm, Operating Voltage 220-240 V And Frequency 50 Hz, Including A Downrod Of Suitable Size And Electrical Connection With 3 Core Flexible Cu Conductor Cable Of Appropriate Size From Ceiling Rose To The Fan Complete All As Specified And Directed. Nmake: Crompton Cat-Part No. Entrust50 Or Havells Cat- Part No. Es-50 Or Equivalent Model Of Usha Or Bajaj 18 S & F Engery Efficient Non-Metalic Fresh Air Fan Having Blade Sweep 250 Mm, Air Delivery Not Less Than 860 Cmh, Operating Voltage 220-240 V And Frequency 50 Hz, Including Electrical Connection With 3 Core Flexible Cu Conductor Cable Of Appropriate Size From Ceiling Rose To The Fresh-Air Fan Complete All As Specified And Directed. Nmake: Crompton Cat-Part No. Ventilus 10 Or Equivalent Model Of Usha, Havells Or Bajaj 19 S & F Energy Efficient Metalic Exhaust Fan Having Blade Sweep 300 Mm, Air Delivery Not Less Than 900 Cmh, Operating Voltage 220-240 V And Frequency 50 Hz, Including Electrical Connection With 3 Core Flexible Cu Conductor Cable Of Appropriate Size From Ceiling Rose To The Fresh-Air Fan Complete All As Specified And Directed. Nmake: Crompton Cat-Part No. Trans Air 12 Or Equivalent Model Of Usha, Havells Or Bajaj 20 S & F Vertical Triple Pole & Neutral, Double Door, Metallic Modular Distribution Board Conforming To Iec 61439-3, Suitable For Flush / Surface Mounting With Provision For Mccb Up To 250 A As Incomer And Sp / Tp Mcbs As Outgoing, Reversible Metal Door, Fully Insulated 400A Copper Busbar For Each Phase, Two Fully Insulated & Shrouded Neutral Bars, Two Earthbars, Cable Ties For Cable Management, Prefitted Masking Sheet, Etc. Having Ik 09 & Ip 43 Protection Complete All As Specified And Directed. Nnotes: N [ I ] Mcbs / Rcbos / Mccbs Shall Be Measured And Paid In Revelant Items. N Vertical Triple Pole And Neutral Db, 4 Way Nmake: Legrand Ekinox³ Cat-Part No. 5077 25 Or Equivalent Model Of Schneider, Siemens Or Abb N N N N 21 S & F Mcb For Ac Applications Conforming To Is / Iec 60898-1-2002, Having Breaking Capacity Icn = 10 Ka, Sliding Bottom Clamp, Colour Coded On / Off Indication On Dolly, Biconnect Ip 20 Protected Lower Terminals And Sliding Shutters, Etc. Complete All As Specified And Directed By Engineer-In-Charge. Nmake: Schneider, Legrand, Havells N ( A ) 6 A, Sp Mcb, C- Curve N 22 ( B ) 16 A, Sp Mcb, C- Curve 23 ( C ) 20 A, Sp Mcb, C- Curve 24 ( D ) 20 A, Dp Rcbo, C- Curve 25 ( E ) 32 A, Tp Mcb, C- Curve 26 ( F ) 32 A, Tpn Rcbo, C- Curve 27 ( G ) 63 A, Tp Mcb, C- Curve 28 S & F Moulded Case Circuit Breaker ( Mccb ) , Four Pole, In Single Frame Size Up To 250 A With Thermal Magnetic Trip Unit ( Tmd ) , Compression Lug Connectors, Protection Against Overloads ( Ir Adjustable From 0.7- 1 X In ) , Protection Against Short Circuits ( Isd Adjustable From 1.5- 10 X Ir ) , Inbuilt Encapsulated Double Break Roto Active Type Instanteneous Protection, Earth Fault Leakage Protection, Etc. Having Ics = 100% Icu As Per Iec 60947-2 Complete All As Specified And Directed By Engineer-In-Charge. Nmake:Legrand, Schneider, Siemens, Abb N ( A ) 200 A, 415 V, 16 Ka, 50 Hz Fp Mccb 29 ( B ) 100 A, 415 V, 16 Ka, 50 Hz Tp Mccb 30 M & L For Earthing Complete With Galvanized Steel Earth Plate Electrode Of 60 Cm X 60 Cm X 6 Mm Size, Buried Directly In Ground ( Earth Pit Not Less Than 2.25 M Deep Below Ground Level ) With Top Edge Of The Plate Not Less Than 1.5 M Below Normal Ground Level, Connected To Galvanised Iron Strip Of Size 32X6 Mm As Earth Lead, By Means Of Bolts, Buts, Check Nuts And Washers Of Galvanised Iron Or Steel, Galvanized Iron Pipe Of 40 Mm Diameter, Connected To Earthing Test Point, All As Shown In Electrical Plate No. 3 Connected To Earthing Test Point All As Specified Or Indicated Including Testing On Completion And Including Excavation, Earthwork, Pcc Earth Pit Of Dimensions 550 Mm X 550 Mm ( Outer ) And 300 Mm X 300 Mm ( Inner ) And 250 Mm Deep, With A 10 Mm Thick Ci Cover, Hinged To Ci Frame On Ground Level, Gi Watering Pipe, Funnel, Etc. As All Specified And Directed. 31 ( Road / Path / Culvert ) Ns & F 9 To 10Mm Thick Coloured Designer Heavy Duty Vitrified Non Skid Pavement Tiles Of Approved Pattern All As Specified And Directed. 32 Filtration System Nsupply, Installation, Testing & Commissioning Of Circulating Pumps Cast Iron Pumps 3000 R.P.M. Mechanical Seal In Stainless Steel. I.P.-54 Motor Protection. Stainless Steel Shaft. With Stainless Steel Strainer Basket. Conn. ( 2 Working 1 Standby ) Flow Rate : 80M3 / H @ 30M.Head. Nmake: Kirlosker, Jhonson, Wilo, Astral Pool. 33 M&L For Pn 1.6 Rated 200Mm Nb Polypropelene Vortex Inhabitor Suction Lift Conforming To Bs 4504 With Stainless Wire Mesh, Bolts, Nuts And Washers Etc Complete All As Specified And Directed By Engineer In Charge ( For Suction Side Balancing Tank ) . Make:- Frekline Hose / Tyco / Associated Enterprise 34 Providing And Fixing Multigrade Sand Filter Of Filter Flow Rate Of 80 M3 / Hr With A Filtration Velocity Of 15 M3 / Hr / M2 And Sized At 2400Mm Dia Filter Inlet And Outlet Ports Sized At 150Mm , 6Mm , 6 Mm Shell & Dish Thickness . Nmodel - Indion Mgf 2000 -2W Of Make Ion Exchange Nor Equivalent In Astral, Aqnanomis, Pent Air Nnotes: [ I ] Filtration Media Used For The Fine & Course Sand Media Combination Of Fine & Course / Pebbles - 5 Types Media, Specifically Suitable For Filtration With Uniform Coefficient Of 5 Layers Of Media – To The Quantity As Defined By The Filter Manufacturers-Total Media Quantity 9800 Kgs. N [ Ii ] Valve Battery - Frontal Piping Msep. N [ Iii ] Face Piping Of Msep With Butterfly Valves Of 150Mm Manually Regulated To Control Filtration Cycles. [ Make: Audco, Zoloto, Crawley & Ray, Thermax ] 35 Providing & Fixing Plumbing Work Consisting Of Upvc Pipes Sch-80, 10Kg / Cm2 With Pn 16 Grade Heavy Duty Fittings In To The Filtration Station And Discharge Pipework From The Filter To Floor Inlets Of The Pool Inlets Complete With All Heavy Duty Upvc Fittings And Adaptors Pasted Using Approved Solvent Cement & Testing To A Holding Pressure Of 3.5 Kg / Cm2 For A Period Of 6 Hours, As Per Specifications And Instructions Of The Engineer - In - Charge. Nmake: Finolex, Supreme, Prince N A ) 200Mm Nb 36 S & F Concrete Floor Inlet With Ss Screw Flow 12 M3 / Hr With 2 Female And Male Connection Pool Inlets White Abs Plastic Bottom Inlet For Concrete With S.S. Screws And Regulable Flow. Min. Flow / Inlet = 5, 000 Ltr / Hr Nmake : Astral Pool, Certikin, Ion Exchange. 37 Supply, Installation, Testing And Commissioning Of Main Drain Ss 304 Square Main Drain 450Mm X 450Mm With Main Frame Screwed On Base Frame Also In Ss 304 Duly Groutable On The Pool Bottom Deepest Part. The Drain Plate Should Be Able To Collect A Water Volume Of Not Less Than 35 M3 / Hr @ A Drain Velocity Of 1.0 M / Sec. The Hole Size On Drain Plate Not To Exceed 10 Mm And Qty Of Holes To Match The Said Flow. Contractor To Ensure That The Effective Surface Area Of Holes Shall Be Equal To Or More Than The Drain Pipe Size Effective Area Nmake : Astral Pool, Certikin, Ion Exchange 38 Hair & Lint Catcher - Hair Strainner - Size 500 Mm X 700 Mm - Ss 304 Make:- Ion Exchange / Uv Rich / Protcom / Astral Pool 39 Suction Trolly Sytsem, Trolly Mounted Suction Sweeper With , 600 Mm Ss Vaccum Head With - 2 Sets Of Nylon Brush & 30 Mt Long Vaccum Hose , Cleaning Accessaries- Algae Brush , Curved Brush, Leaf Rack , Leaf Skimmer , Starter , Cable & Starter . Etc. Complete. Make:- Astral Pool / Certikin / Pent Air / Ion Exchange 40 Supply, Installation, Testing And Commissioning Of Dosing Pump For Disinfectant Dosing Membrane Electronic Dosing Pump To Be Mounted Both On Its Base As Well As Hung On The Wall. Pumps Following Ce Regulations. Ip- 65 Protection. Required Power Connections Is 220 / 240V, 50 / 60 Hz. The Materials In Contact With Liquid Should Be : Polypropylene, Viton, Teflon And Pvc. Flow Rate Of Pump Shall Be 20Ltr / Hr @ 5 Bar. Nmake : Astral Pool, Certikin, Ion Exchange 41 Supply, Installation, Testing And Commissioning Of Solution Preparation Tank Semi-Transparent Polyethylene Tank With External Scale So That Levels Can Be Checked Easily, Capacity Of Tank Should Be 500 Litres Rested On The Finished Floor . The Above Doser Shall Suck The Chemicals From The Tank As Desired For The Pool Water Disinfection. Nmake : Astral Pool, Certikin 42 Supply, Installation, Testing And Commissioning Of Agitators For Easy Installation In The Tanks, Provided With Steering Grip In Bakelite, Rod And Propeller Arms In Pvc, Length Of Stirring Rod To Be Minimum 900 Mm Long So That The Chemicals In The Tank Can Be Stirred Properly. Nmake : Astral Pool, Certikin, Ion Exchange. 43 Chlorine / Ph Test Kit Along With Testing Liquid For Checking Ppm Level Minimum Quantity 12 Months On Basis 2 Test Per Day. Nmake : Astral Pool, Certikin, Ion Exchange, Uv Rich 44 Supply, Installation, Testing And Commissioning Ionization System For 8.0 Lacs Litres Of Water For Superior Control Of Algae And Bacterial Contamination In Pool Water By Introducing Copper And Silver Ions In Controlled Quantities By Electrolysis Method, With 2 Nos. Electrolyzing Chamber Ss-304 With Copper & Silver Electrode, Piping, Cabling & Equipped With An Electronic Control Panel Comprising Voltage Variation Devices, Ammeters, Auto Timers, Switches, Indicator Lights, Etc. Nmake : Astral Pool, Certikin, Ion Exchange, Uv Rich 45 Supply, Installation, Testing And Commissioning Of Overflow Gratings Overflow Gratings Of Size 250Mm Wide 24Mm Ht And Made In Abs / Pp And Able To Be Fixed On Straight As Well As Curved Channels . Corner Supports In Ss 304 To Be Supplied For Fixing At Four Pool Corners. Rate Shall Be Inclusive With Corner Supports Required In The Swimming Pool. Nmake : Astral Pool, Certikin, Ion Exchange. 46 Starting Blocks For Competition Pools. Adjustable Platform In Polyester And Fibreglass With Non-Slip Finish 500Mm X 500Mm. Complete With Fixing. Polished Finish With Height : 400Mm. Nmake : Astral Pool, Certikin, Ion Exchange. 47 Supply, Installation, Testing And Commissioning Of Factory Made, Cpri Type Tested, Indoor Cubical Compartmental Type Plant Room Panel Of Suitable Size, Conforming To Iec 61439-1 & 2 And Iec 61641, Having Both Sides Openable With Hinged Double Doors And Locking Arrangement, Ip 43 Protection Made Out Of 2.0 Mm Thick Mild Steel Crca Sheet, Supported And Fixed On Structural Frame Of Angle Iron Of Suitable Size, Including Earthing Stud, Labelling, Painting To All Internal & External Exposed Steel Surfaces With Powder Coating Paint ( 7 Tank Process ) , Duly Fixed In Ground With Pcc Foundation ( 1:2:4 ) Type B1, With Danger Notice Plate Of 1.6 Mm Thick Mild Steel Vitreous Enamelled ( White ) With Letters, Figures And Conventional Skull And Bones In Signal Red Colour Suitable For 3- Phase, 4 Wire System, 500 V Grade With Necessary Wiring, Pvc Sheathed Stranded Copper Conductor Of Appropriate Length And Size, Including Fixing Lugs, Bolts, Screws, Etc. Complete All As Specified And Directed By Engineer-In-Charge. Nmake: From Authorised Vender Of L & T, Schneider, Siemens, Legrand Nthe Panel Shall Comprise Of The Following: N [ A ] Busbar Chamber N [ I ] 01 Set ( 3L + N ) Of Copper Busbar Of Rated Capacity 160 A, Covered With Pvc Insulated Sleeves Including Insulator, Nuts, Bolts, Etc. With Complete Connection N [ B ] Incoming [ I ] 100 A, 415 V, Ics = 100% Icu = 25 Ka, 50 Hz Fp Mccb, Conforming To Iec 60947-2, Having Microprocessor Based Trip Unit, Adjustable Overload Setting ( 0.7 - 1 X In ) , Adjustable Short-Circuit Setting ( 5 - 10 X Ir ) , Adjustable Neutral Protection ( N, N / 2, Off ) , Front Indication Leds ( Ready, Overload And Pre-Alarm & Overload ) , Etc.- 01 Nos. N [ Ii ] Cl 1.0 Multi-Function Meter Capable Of Measuring V, A, F, Pf, W / Va, Wh / Vah, Runhrs. Onhrs & Interupts- 01 Nos. 48 [ Iii ] Led Phase Indicators ( Red, Yellow, Blue ) - 01 Set N [ B ] Outgoing [ I ] 40 A, 16 Ka, 415 V, 50 Hz Tp Mccb ( C -Curve ) , Front Indication Leds With Fully Automatic Star / Delta Starter Suitable For Main Circulating Pump, Complete With Contactors, Push Button ( S ) , Led Indicators, Auto / Manual Selector Switch, Overload Protection, Current Sensing Type Single Phase Preventer, Etc. Complete With All Accessories And Wiring, Etc.- 03 Nos. [ For Circulating Pump ] N [ Ii ] 32 A, 10 Ka, 230 V, 50 Hz Spn Mcb ( C -Curve ) - 01 Nos. [ For Plant Room Dbs ] N [ Iii ] 16 A, 10 Ka, 230 V, 50 Hz Spn Mcb ( C -Curve ) - 02 Nos. [ For Under Water Light ] N [ Iv ] 6 A, 10 Ka, 230 V, 50 Hz Sp Mcb ( C -Curve ) - 03 Nos. [ For Dosing Pump ] Nnotes: [ I ] 01 Nos. Of On / Off / Trip Status And Operations Counters As Well As Meters Shall Be Wired To Ethernet Gateway Part Of The Panel. N [ Ii ] The Bidder Shall Furnish Dimensional Drawings Of The Items Offered, Indicating All The Fittings, Dimensional Tolerances, Typical Gads, Etc. With Details Of Insulation At Each Point And Core Construction, Etc. For Approval Of The Garrison Engineer. N [ Iii ] The Bidder Shall Intimate The Garrison Engineer Of The Routine Tests In Accordance With Iec 61439-1 & 2 And Iec 61641 In The Oem Factory In Presence Of A Representative Nominated By The Garrison Engineer Before Dispatch. 49 M & L For 4 Core Pvc Insulated And Sheathed Industrial Flat Cables For Submersible Motor, Working Voltage Upto And Including 1100 Volts, As Per Is 694: 2010 ( For Panel To Motor Set Connecting ) Nmake : Rr Kabel, Havells, Finolex N ( A ) 4 Core, 16 Sqmm 50 M & L For Construction Of Fly-Ash Brick Masonary Valve Chamber Of Size 600 Mm X 600 Mm X 900 Mm ( Internal Dimenssions ) With Pcc Foundation 1:4:8 Type D2 Using 40 Mm Graded Stone Aggregate, 150 Mm Thick & 150 Mm Wide Offsets Around Over 100 Mm Thick Hardcore , 200 Mm Thick Fly-Ash Brick Masonry Walls Built In Cm 1:6, 100 Mm Thick Pcc 1:2:4 Type B1 Coping Finished Even And Smooth, Rendering 10 Mm Thick In Cement Mortar ( 1:6 ) Finished Even And Smooth, With Out Using Extra Cement Internally Including Top Of Floor Including Excavation Earth Work In Hard / Dense Soil 6 Mm Thick Ms Sheet Cover Fixed On 25 Mm X 25 Mm X 6 Mm Thick Angle Iron Frame With Hold Fasts Embedded In Pcc Coaping With Locking Arrangement, Mild Steel Handle And Painting To Steel Surfaces With Two Coats Of Synthetic Enamel Paint Over One Coat Of Primer Including Disposal Of Surplus Soil To A Distance Not Exceeding 50 M Etc Complete All As Specified And Directed. 51 External Water Supply Nsupply, Testing And Commissioning Of Centrifugal Pump Set Of Discharge Capacity 900 Lpm At 40 Mtr Head, Split Casing Type, 80X80mm Suction / Discharge And Coupled With Suitable Rating Induction Motor 3 Phase 415 Volts, 50 Hz Mounted On Ms Chanel / Common Base Plate And Fixed With Suitable Bolts, Grouted In Pcc Foundation, 30 Cm Above Floor Level Including Pvc Insulated Single Core Unsheathed Copper Conductor Of 06 Sqmm Size Drawn In Pvc Conduit For Connection From Starter To Motor Terminal. Make:- Kirloskar, Crompton Greaves, Beacon, Ksb. Note:- Provision For Priming System With 20Mm Gi Pipe And Control Valve Is Deemed To Be Included In Quoted Rate. N N 52 Supply, Laying And Jointing On Floor / Wall Class K9 Of Standard Length Double Flange ( Screwed ) Pipes, Internal Cement Mortar Coating An External Surface With Bituminous Paint Of Size 80 Mm Dia Isi All As Specified And Directed Nmake:Electrosteel / Jindal Saw / Tata Metaliks 53 Supply And Fix Foot Valve Ball Type Of 80 Mm Dia Flange Type Compele All As Specified And Directed. Make:- Kirloskar, Leader, Sant, Audco. 54 Supply, Laying And Jointing In Trenches Di Pipes Class K7 Of Standard Length Spigot And Socketed End Push Type Joint With Rubber Gasket As Jointing Material, Internal Cement Mortar Coating An External Surface With Bituminous Paint Of Size 100 Mm Dia Isi All As Specified And Directed. Nmake Electrosteel / Jindal Saw / Tata Metaliks 55 Material And Labour For Di Fittings And Fixtures Bends ( Any Type, Radius And Angle ) Tapers Any Type, ( Straight, Bend, Increasing, Decreasing Or Double Socket Etc. ) Tee Pieces Single Branch Y Junction, Double Branch, Cross ( All Sockets Or Socket And Spigot ) Collars, Cap And Plugs Upto 150Mm Bore 56 M&L For Lt Panel Board Cubical Kiosk Outdoor Type Compact 415 Vots Ac 50 Hz, 4 Wire +E, Fabricated Polycarbonate, Nominal Size 900Mmx600x660mm, Ral 7035 Finish Confirming To Ip 54 Complete Including Cu Bus Bar 100 Amps, 4 Strip Mounted On Porcelain Insulated Enclosed In Chamber, Bottom Cable Entry Comprising Of Foliowing N ( A ) Incoming Mccb 63 Amp 4 Pole With Microprocessor Based Release Having Breaking Capacity 36 Ka 01 Nos N ( B ) Outgoing Mccb 32 Amps 415 V, Triple Pole, 25Ka 02 No N ( C ) Digital Panel Meter For Amp, Volt, Kwh, Power Factor And Other Parameter Flush Mounting Of Size 96X96mm. N ( D ) Star Delta Starter Contactor, Push Buttons, Led Indicators Of Suitable Capacity Including Over Load Protection Single Phase Preventor Etc, Suiable For Pump Set - 02 Nos 57 S & F Ball Plug 200Mm Bore All As Specified & Directed. 58 S & F Well Cap 200Mm Size Threaded And Similar To Housing Pipe All As Specified & Directed N 59 S & F 2 Nos Ms Flat Iron 100Mm X 10Mm Thick Size Clamp For Holding With 250 Mm Bore Housing Pipe Including Casting Of Pcc Block Of Size 1200Mm X 1000Mm X 1000Mm In Pcc ( 1:2:4 ) Type B-1 Using 20 Graded Stone Aggregate Including 150Mm Bore Ms Pipe 2 No Each, 1.5 Metre Long With Cap Plug And Cap Top For Loading Pea Gravel For Each Bore Well As Specified And Directed. 60 Supply Only Strata Sample Box With Glass Cover 3Mm Thick Having Internal Dimension 100X100x600mm Made Out Of 20Mm Thick Wood With Hinges, Hasp And Staple Including Polishing Complete With Samples At Various Strata Met In Boring Including Strata Chartin Duplicate 61 Electric Logging In Pilot Bore For Precise Delineation Of Granular Zones As Also The Quality Of Ground Water Including Report Interpretation Complete As Specified Nnote: Electric Logging Shall Be Carried Out By Any Approved Govt Agency Or Geologist. 62 Material And Labour For Drilling Trial Bore Through Direct Hammering ( Dth ) Technique In Any Type Of Strata Consisting Of 250 Mm Dia Drill Bit For Depth Upto 200M In Sequence From Ground Level As Given Below For Bore Well Complete As Per Is-2800 Part-1 1991, The Following Tests And Reporting Will Be Carried Out By The Contractor And Approved By Ge As Per Is- 2800 Part 1 1991 :- N ( I ) Recording The Well Discharge During Drilling By A 90 Degree V Notch. N ( Ii ) Recording The Water Bearing Horizon. N ( Iii ) Taking The Samples From The Borewell Cutting For Every 3 Meter Interval And Every Change In Strata If Less Than 3 Meter. N ( Iv ) Preparation Of Litho Logs Based On These Samples. N ( V ) Drill Time Log To Be Prepared And Prescribed. N ( Vi ) Aquifer Performance Tests At Constant Discharge With Draw Down Nand Recovery Reading. N ( Vii ) Interpretation Of Data And Preparation Of Hydro Scientific Report For Designing Of Submersible Pump And Article Recharge Studies 63 Supply Assembling, Jointing, Lowering And Fixing In The Bore Hole Pvc Casing Pipe Of Nominal Dia 200 Mm ( Medium Well ) , 7.5 Mm Thickness Confirm To Is 12818-2010 Including Providing Pea Gravel Of 8Mm To 4.6Mm Size For Packing Around The Casing / Slotted Pipe In Bore Well As Specified And Directed Nmake : Astral / Ashirwad / Ajay 64 Supply Assembling, Jointing, Lowering And Fixing In The Bore Hole Upvc Slotted Pipe Of Nominal Dia 200 Mm ( Medium Well ) , 7.5 Mm Thickness Confirm To Is 12818-2010 Including Providing Pea Gravel Of 8Mm To 4.6Mm Size For Packing Around The Casing / Slotted Pipe In Bore Well As Specified And Directed Nmake : Astral / Ashirwad / Ajay 65 Developing The Tube Well By Means With 250 Psi Air Compressor All As Specified In Is-11180-1865 Para 4.3 And As Directed 66 Developing The Tube Well By Means Of Over Pumping All As Specified And As Directed. Nnote: Over Pumping Will Be Carried Out By Pumping The Well At Higher Capacity I.E. Not Less Than 50% Above The Yield Of Well 67 Yield Testing Of The Tube Well As Specified And Directed To Determine The Safe Pumping Capacity Of Tube Well 68 Supply, Installation / Lowering Submersible Pumpset, Discharge 150 Lpm And Head 80 M. Electric Driven, 415 V, Tp Suitable For 200 / 250 Mm Dia Borewell, Stainless Steel Body, Water Filled Fitted With Non Return Valve To Prevent Backflow, With Suitable Capacity Of Starter Panel And Submersible Copper Cable Of Rating As Per Manufacturer ( Trom Panel To Submersible Motor, Length Of Cable As Per Site Requirement ) All Specified And Directed By Engineer-In Charge. Nmake Crompton Greaves / Ksb / Kirloskar Brothers / Texmo 69 Supply & Fix Pump Guard Set With Flange 63Mm All As Specifed. 70 Supply, Assembling, Jointing. Lowering Lead Free Upvc Column Pipes Of Nominal Dia 65 Mm, Od 75 Mm ( Min ) , Non Toxic, Pressure 26 Kg / Cm2 With And Including Top And Bottom Adaptor ( Ss ) And Accessories Like Epdm Ring And Double Ss Stud All As Specified And Directed By Engineer-In-Charge. Nmake : Astral / Ashirwad / Ajay 71 Supply And Fix Pp-R Pipes Sdr 6 ( Pn-20 ) And Pp-R Plain Fittings In Trenches / Walls / Ceilings Or Laying In Floors Complete Of Following Sizes Including Fittiings N ( A ) 90 Mm Outer Dia 72 ( B ) 50 Mm Outer Dia 73 ( C ) 32 Mm Outer Dia 74 Material And Labour For Construction Of For Valve Pit / Chamber In Pcc Solid Block Masonry ( 1:5:8 ) Built In Cm 1:6 Over 150 Mm Thick Pcc Loundation 1:3:6 Type C2, 10Mm Thick Intemal Cm 1:6 & 12Mm Thich External Plaster In Cm 1:4 Provided With 3 Mm Thick Ms Sheet Cover And Ms Angle Iron Chamber Frame Fixed In Coping In Pcc 1:2:4 Type B-1 With Locking Arrangement And Handle, Painting Of Ms Work With One Coat Of Red Oxide Primer And Two Coat Of Synthetic Enamel Black Paint Complete Including Excavation & Earth Work In Any Type Of Strata Complete All As Shown An Drawing No.Ceaa / Td / 57 Sheet No 1 / 1, Dated 28 05.92 Amended Upto 31.12.92, But Of Internal Size 1050Mm ( L ) X 750Mm ( B ) X 1000Mm ( D ) Etc Complete All As Specified Arid Directed. N Note:- Excavation, Return Filling And Removal Of Soil Etc Is Deemed To Be Inclusive In Quoted Rate. 75 M & L For Geoelectric Investigation For Groundwater Assembly By Sophisticated Digital Deep Resistivity Monitors On Suitabie 3 Spot 150 M Depth To Delineate Saturated Thickness, Extent Of Fracturing At Deeper Level To Analyze Quantitative And Qualitative Potential Of The Area & To Including Calibration To Determine The Aquifer System Of The Area & To Determine Quantity And Quality At Each Side And Select Suitable Site For Tube Well With Salinity Level. Nnote Cost Of Mobilization Of Equipment / T & P And Preparation Of Report Included In Item Rate. N 76 External Electrification Nsupply And Lay Double Wall Corrugated ( Dwc ) High Density Polythene Pipes Of Nsize 90 Mm Od ( Nominal ) With All Fittings Having Corrugation On The Outer Wall And Plain Surface On The Inner Wall Confirming To Is 14930 ( Part I And Ii ) For Protection Of Underground Cables Laid In Trenches / Road / Nallah Or Fixed Along Wall, Poles Or Laid Under Floor Including Cutting Floor / Road And Making Good To Match With Existing Adjoining Surface Etc For Cable Protection All As Specified ( Excavation And Earth Work Shall Be Measured And Paid Separately ) N Make Rex / Poly / Gemini N 77 Supply And Fix Octagonal Hot-Dip Galvanized Street Light Poles Including Junction Box, Height 7 Mtrs, Top Dia 70Mm, Bottom Dia 130 Mm, Sheet Thickness 3 Mm, Base Plate 220X220x12, Foundation Nut Bolts As Per Manufacturer Recommendation Including Reinforced Cement Concrete Foundation And Hot Dip Galvanised Bracket Single Arm For Fixing Of Street Light And One No Of Mcb 6 Amp Including 25 Amp Four Way Terminal Block All As Specified And Directed. Nmake: Bajaj Surya / Philips / Utkarsh 78 Supply & Fix Led Lights, Nominal Watt 150 Watt, Nominal Lumen Efficancy 90 Lumen / Watt, High Pressure Die Cast Aluminium Housing, 140-270V, 50 Hz. Pf>0.95 Led Flood Light Luminaries Mounted On Wall Complete All As Specified And As Directed By Engr-In Charge. N Make: Philips / Wipro [ Skyline ) Lf20-192 060-57-Xx / Osram ( Strada Plus ) N 79 Supply & Fix Led Lights, Nominal Wat 30 Watt, Nominal Lumen Efficancy 90 Lumen / Watt, High Pressure Die Cast Aluminium Housing, 140-270V. 50 Hz. Pf>0.95 Led Street Light Luminaries To Be Mounted On Octagonal Hot-Dip Galvanized Street Light Poles Including 3 Core 1 Sqmm Pvc Insulated Copper Cable From Control Box To Fitting Complete All As Specified And As Directed By Engr-In Charge Nmake: Philips ) / Wipro ( Skyline ) Lro2-331 Xxx57 / Osram ( Strada Plus ) 80 Supply And Lay Double Wall Corrugated ( Dwc ) High Density Polythene Pipes Having Corrugation On The Outer Wall And Plain Surface On The Inner Wall Confirming To Isi 14930 ( Part I And Ii ) For Protection Of Underground Calbes Of Size 63 Mm Outer Dia With All Fittings. Laid In Trenches / Road / Nallah Or Fixed Along Wall Poles Or Laid Under Floor Including Cutting Floor / Road And Making Good To Match With Existing Adjoining Surface Etc For Cable Protection All As Specified ( Excavation And Earth Work Shall Be Measured And Paid Separately ) Nmake: Rex / Poly / Gemini 81 Supply And Fix Time Switches 415V 3 Phase 5 Kw With Contactor Fitted Inside Steel Enclosure Including Incoming And Out Going Mcbs, Power Contactors And Smc Enlosure For Encasing Complete 3-Phase Circuit Board Along With Nature Switch-02 All As Specified And Directed By Engineer-In-Charge. Nmake:- Swadeep, L&T, Abb, Bajaj 82 Outsourcing Of Services For Operation Of Swimming Pool Including Connected Machineries And Controlled Valves For Two Shifts And Each Shift Of 08 Hrs I.E. 0600 Hrs To 1400 Hrs And 1400 Hrs To 2200Hrs On All Working Days Including Sunday And Holidays With One Operator Per Shift And Keeping Installation Neat And Clean For Trouble Free Operation Including Maintaining Water In Appropriate Norms By Mixing Tcca-90, Calcium Hypochlorite, Alum, Copper Sulphate Etc An Cleaning The Bottom And Sides Of The Pool By Suction Sweeper Whenever Necessary All As Directed By Engr-In-Charge. Nswimming Pool Plant Details: Na ) Filtration Plant Capacity – 80 M3 / Hr Nb ) Centrifugal Pump ( 03Nos ) - 80 M3 / Hr Nc ) Sand Filter ( O2 Nos ) Nd ) Chlorine Dosing Pump ( 03 Nos ) Ne ) Centrifugal Pump 900 Lpm 30 M Head ( 02 ) Nos N Nnote:- N ( I ) Contractor Will Submit The Nominal Roll, Qualification Certificate / Experience Certificate Of Operator Before Commencement Of Outsourcing. N 83 ( Ii ) The Operator Shall Be Iti Qualified In Respective Trade Or Shall Have Minimum 2 Years Experience In Operation Of Swimming Pool. N ( Iii ) Contractors Will Ensure Attendance Of All Operators Shift Wise, If Any Operator Found Absent From Duty A Recovery Of Double The Rate Quoted By The Contractor Against Each Shift / Item Shall Be Made. N ( Iv ) The Tradesman / Operator Should Maintain Proper Hygiene Of Swimming Pool As Instructed By Je E / M In Charge. He Should Have Sufficient Knowledge About Pool Water Chemistry. The Operator Should Maintain The Daily Log Sheet Of The Pool As Instructed By The Concerned Je E / M. In Addition To Running The Plant His Duty Includes Mixing Of Sufficient Chemical In The Swimming Pool / Balancing Tank And Maintaining The Water In Its Standard Level By Controlling Ph Value Between 7.2 To 7.6 And Free Chlorine Value Not Less Than 1Ppm As Per Is 3928-1993. N ( V ) Necessary Pool Chemicals Such As Tcca-90, Calcium Hypochlorite, Alum, Copper Sulphate Etc Will Be Supplied By The Department As Supply Only. N N ( Vi ) All Necessary T&P Including Uniform Shall Be Provided By Contractor To The Operator At No Extra Cost. The Rates For The Same Are Deemed To Be Included In The Unit Rates Of The Item. N ( Vii ) The Contractor Will Provide All The Necessary Stationery Such As Log Book, Attendance Register Etc To The Operator For Maintaining The Plant Running Record. N ( Viii ) All Operator Shall Wear Proper Uniform. N
Contract Date : 08 Jun, 2021   |   Contract Value : 3.55 Crore
Disclaimer

We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.

Tender Detail
Website https://etender.cpwd.gov.in/login.html
Quantity
MSME Exemption No
Tender Type Open Tender
Startup Exemption Click Here
Competitive Bidding NCB
Similar Tenders
TENDER INSIGHTS

858

Electric Tenders
Live
CLICK TO KNOW MAXIMUM WIN

Tell us about your Product / Services,

We will Find Tenders for you

🇮🇳 +91
TenderDetail
Loading tenders