Tender Summary / Eligibility Criteria
Construction Of Canteen Service Facilities At IIT(ISM), Dhanbad. SH: Providing, Installing, Testing And Commissioning Of Hygenic Stainless Steel Kitchen Drainage System.
Documents
Download All
No Boq
No Corrigendum
Probable Bidders
AI engine predicts probable bidders to help you bid strategically.
MSME Exception
Technical
Tender involves procurement of high capacity electrical equipment including diaphragm coupling of pump &
motor with 90kW capacity at 2900 RPM. The project scope includes installation, testing, commissioning and
operational handover.
Previous / Similar Result
BRR : 8713685
Supply And Fixing Of Kitchen Equipment At Sap Camp , Thiruvananthapuram - 2 15.7.4 Ndemolishing Brick Work Manually / By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge. Nin Cement Mortar 3 15.13.2 Ntaking Out Doors, Windows And Clerestory Window Shutters ( Steel Or Wood ) Including Stacking Within 50 Metres Lead:Of Area Beyond 3 Sq. Metres 4 15.23.1 Ndismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Metres Lead. Nfor Thickness Of Tiles 10 Mm To 25 Mm 5 9.1.1 Nproviding Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length ( Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately ) . Nsecond Class Teak Wood 6 9.7.1 Nproviding And Fixing Panelling Or Panelling And Glazing In Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows ( Area Of Opening For Panel Inserts Excluding Portion Inside Grooves Or Rebates To Be Measured ) , Panelling For Panelled Or Panelled And Glazed Shutters 25 Mm To 40 Mm Thick: Nsecond Class Teak Wood N 7 4.1.6 Nproviding And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level: N1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 40 Mm Nominal Size ) 8 2.25 Nfilling Available Excavated Earth ( Excluding Rock ) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Up To 1.5 M. 9 6.3.2 N Brick Work With Common Burnt Clay Machine Moulded Perforated Bricks Of Classdesignation 12.5 Conforming To Is: 2222 In Superstructure Above Plinth Level Up Tofloor Five Level In Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) : Nwith Modular Bricks ( From Floor 2 Level Up To Floor 5 Level ) 10 10.29.1 Nproviding & Fixing Fly Proof Wire Gauze To Windows, Clerestory Windows & Doors With M.S. Flat 15X3 Mm And Nuts & Bolts Complete. Ngalvanised M.S. Wire Gauze With 0.63 Mm Dia Wire And 1.4 Mm Aperture On Both Sides N 11 10.16.1 N Steel Work In Built Up Tubular ( Round, Square Or Rectangular Hollow Tubes Etc. ) Trusses Etc., Including Cutting, Hoisting, Fixing Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. Nhot Finished Welded Type Tubes 12 12.1.3 Nproviding Corrugate G.S. Sheet Roofing Including Vertical / Curved Surface Fixed With Polymer Coated J Or L Hooks, Bolts And Nuts 8 Mm Diameter With Bitumen And G.I. Limpet Washers Or With G.I. Limpet Washers Filled With White Lead, Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete ( Up To Any Pitch In Horizontal / Vertical Or Curved Surfaces ) , Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. N0.63 Mm Thick With Zinc Coating Not Less Than 275 Gm / M2 13 13.5.1 N15 Mm Cement Plaster On Rough Side Of Single Or Half Brick Wall Of Mix: N1:4 ( 1 Cement : 4 Coarse Sand ) N 14 13.37.1 Nwhite Washing With Lime To Give An Even Shade: Nnew Work ( Three Or More Coats ) N 15 13.48.1 Nfinishing With Deluxe Multi Surface Paint System For Interiors And Exteriors Using Primer As Per Manufacturers Specifications: Ntwo Or More Coats Applied On Walls @ 1.25 Ltr / 10 Sqm Over And Including One Coat Of Special Primer Applied @ 0.75 Ltr / 10 Sqm 16 13.48.3 Nfinishing With Deluxe Multi Surface Paint System For Interiors And Exteriors Using Primer As Per Manufacturers Specifications: Npainting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied @ 0.90 Ltr / 10 Sqm Over An Under Coat Of Primer Applied @ 0.80 Ltr / 10 Sqm Of Approved Brand And Manufacture 17 13.48.2 N Finishing With Deluxe Multi Surface Paint System For Interiors And Exteriors Using Primer As Per Manufacturers Specifications: Npainting Wood Work With Deluxe Multi Surface Paint Of Required Shade. Two Or More Coat Applied @ 0.90 Ltr / 10 Sqm Over An Under Coat Of Primer Applied @ 0.75 Ltr / 10 Sqm Of Approved Brand And Manufacture 18 N10.4 Nproviding And Fixing 1 Mm Thick M.S. Sheet Sliding- Shutters, With Frame And Diagonal Braces Of 40X40x6 Mm Angle Iron, 3 Mm M.S. Gusset Plates At The Junction And Corners, 25 Mm Dia Pulley, 40X40x6 Mm Angle And T-Iron Guide At The Top And Bottom Respectively, Including Applying A Priming Coat Of Approved Steel Primer. 19 Drainage System 20 50.18.9.9.1 Nproviding And Fixing Pvc Pipes Includings Jointing Of Pipes With One Step Pvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge.110 Mm Dia 6Kgf / Cm2 21 50.18.9.22.1 Nproviding And Fixing Pvc Moulded Fittings / Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 110 Mm Dia Elbow 22 50.18.9.22.2 Nproviding And Fixing Pvc Moulded Fittings / Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 110 Mm Dia 45 Degree Elbow 23 50.18.9.22.6 Nproviding And Fixing Pvc Moulded Fittings / Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 110X110x110 Mm Dia Door Tee 24 50.18.9.8.1 Nproviding And Fixing Pvc Pipes Includings Jointing Of Pipes With One Step Pvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge. 75 Mm Dia 6 Kgf / Cm2 25 50.18.9.21 Nproviding And Fixing Pvc Moulded Fittings / Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 75 Mm Dia Elbow 26 50.18.9.21.2 Nproviding And Fixing Pvc Moulded Fittings / Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement -75 Mm Dia 45 Degree Elbow 27 50.18.9.21.3 Nproviding And Fixing Pvc Moulded Fittings / Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement-110 Mm Dia Door Elbow 28 5.3 N Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs, Having Slope Up To 150 Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, With1:1.5:3 ( 1 Cement : 1.5 Coarse Sand ( Zone Iii ) : 3 Graded Stone Aggregate 20 Mm Nominal Size ) . 29 5.9.16.2 Ncentering And Shuttering Including Strutting, Etc. And Removal Of Form For: Nedges Of Slabs And Breaks In Floors And Walls Nabove 20 Cm Wide N 30 5.22.6 Nsteel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level Nthermo - Mechanically Treated Bars Of Grade Fe-500D Or More 31 Providing And Fixing Pvc Pipes Including Jointings Of Pipes With One Step Pvc Solvent Cement, Trenching, Refilling And Amp:Amp:Testing Of Joints Complete As Per Direction Of Engineer In Charge. 160 Mm Dia 6Kgf / Cm2; Qty 25 Meter; Rs 650 / Meter 32 Proposed Kitchen Equipment 33 Kitchen Steam Boiler Operated By Lpg Outer Shell Is Made Out Of 8 And 5 Mm Ms Plates Inner Shell Is Made Out Of 2 Mm Thickness 304 Grade S.5 Sheet. Boiler Is Fitted With Gauge Glass Set For Knowing Water Level Safety Valve And Smoke Vent No:5 Model Boiler Size 32X 50 Height With 178 Burner 34 Single Jacketed Rise Vessels It Is Made Out Of 2Mm Thickness ( 14 Swg ) 304 Grade S.S Sheet. Side Support Is Made Out Of 65 Mm Od S.S Rods . Bottom Perforated Sheet Is Provided For Drain Out Of Kanji. Handle Rod Is Provided For Easily Tilting The Vessel. 30 Kg Capacity Rice Vessel, Size 25Od X 25 Height 35 Double Jacketed Sambar Vessel Inner Jacket Is Made Out Of 2 Mm Thickness ( 14Swg ) And Outer Jacket Is Made Out Of ( 14Swg ) 304 Grade S.S Sheet . Side Support Is Made Out Of 65 Mm Od S.S Rods . Handle Rod Is Provided For Easily Tilting The Vessel 100 Litres. Capacity Sambar Ve Ssel Size : 20 Odx 20 Height 36 Frame Vessels Stands Vessels Stand Are Made Out 2 Od S.S Pipes And 8 Mm S.S Plates For Mounting 5 No Vessels 37 240 Nos Capacity Idly Box It Is Made Out Of 18 Swg 304 Grade S.S Sheet . Each Chamber Contains Three Trays And Makes 60 Idly . Four Chambers Make 240 Idly In One Time Within 10 Minuts . No: Of Trays ( 12 +3 ) With S.S Stands. 38 Steam Line Materials 3 / 4 G.I.C Class Pipe For Steam Line , Gi Elbow , T And Ball Valves 39 Steam Line Erection Charges 40 Masonry Work For Platform And Fixing Steam Utensils. Fixing On The Ground And Basement Works ( 15Ft X 6Ft ) No Tiling Required. Drain In Cement With Grout Finish For Waste Water. 41 Chapathy Machine Semi Automatic 2000 Chappathy Per Hour. Single Phase 1Hp Motor. Uncooked Chappathy 42 Commercial Atta Kneader 230-440V 20Kg 43 Ss Tumbler 300 Ml 44 Ss Meals Plate 4 Compartment 45 Dinner Set With Plates And Bowl 33 Piece Porcelean 46 Plate Racks Fabricated In Steel Tube With Painting. 4 Rack 47 Food Placing Table Inside Mess Hall Stainless Steel 2 Shelve 48 Gas Pipe Line Works - 25 Mtrs -With Pipes, Fittings, Connectors, Outlets And Inlets 49 Gas Stove 2 Burner For Kitchen Fabricated In Steel 50 Wet Grinder With Heavy Stand Tiltable Motor Of Capacity 1.5 Hp Equipped With Grinding Capacity Of 15L Robust Design And Sturdy Construction Aids Longer Service Life Hassle Free Operations, Easy Handling And Setup 51 Wet Grinder Non Tiliting, Stainless Steel Drum, 5-7 Kg Capacity. Single Phase Power Supply 52 Heavy Duty Mixer Grinder With Jar Ideal For Both Dry & Wet Grinding, Stainless Steel 2Hp Motor 53 Canteen Seating Stainless Steel Table With 6 Stools Seating Foldable 54 20L Stainless Steel Electric Water Catering Boiler 55 Serving Bowl With Lid L23xb16xh22.5 56 Plain Stainless Steel Water Jug With Handle 57 Serving Spatulas, Rice Spoons, Lids And Accessories 58 Stainless Steel Buckets Heavy Duty 59 Steel Trolley ( Painted ) With Handle And 3 Racks For Heavy Duty Application Upto 300 Kg Weight. Wheels With Foot Lock Brake. 60 Stainless Steel Food Serving Trolley Maximum 50 Kg Support ( 3 Rack ) 61 Double Layered Water Tank, Food Grade, Antibacterial, Uv Resistant, Bpa-Free 1000 Litres 62 Plumbing Line Works From Tank In Upvc And Gi Pipe ( Boiler ) 63 Platform For Watertank In Rcc After Earth Levelling ( 2.2 X 2.2 X 0.20 ) 64 Supply, Installation Testing And Commissioning Of Exhuast Fan Including Wiring With 2.5Sqmm Frls Pvc Insulated, Copper Conductor, Single Core Cable Etc..As Required.380Mm Light Duty Exhuast Fan Working On 230V A / C 65 Supply And Fixing Of High Purification Ro Water Purifier.Purification Production Rate 80L / Hr.Max Duty Cycle 400L / Day.Net Weight 25Kg 66 Electrification 67 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point Nwith 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. 68 Group A ( 1.10.1 ) 69 Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Nconduit As Required. 70 25 Mm ( 1.21.2 ) 71 Supplying And Fixing Of Following Sizes Of Medium Class Pvc Casing And Capping 72 25 Mm ( Lmr ) 73 Supply & Fixing The Following Types / Sizes Of Boxes Suitable For Modular Accessories In Surface / Recess Including Making Good The Damages, Colour Washing Etc As Required ( Rohs Compliant ) ( 90.10.1 ) 74 1 Or 2 Module 75 8 Module 76 Supplying And Fixing Following Modular Base & Cover Plate On Nexisting Modular Metal Boxes Etc. As Required. ( 1.28 ) 77 1 Or 2 Module 78 8 Module 79 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Nfollowing Sizes Of Frls Pvc Insulated Copper Conductor, Single Ncore Cable In Surface / Recessed Medium Class Pvc Conduit As Nrequired. ( 1.14 ) 80 2 X 4 Sq. Mm + 1 X 4 Sq. Mm Earth Wire ( 1.14.3 ) 81 2 X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire ( 1.14.2 ) 82 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. ( 1.17 ) 83 2 X 1Sq. Mm ( Lmr ) 84 3 X 4 Sq. Mm ( 1.17.21 ) 85 2 X 2.5 Sq. Mm ( 1.17.11 ) 86 3 X 2.5 Sq. Mm ( 1.17.12 ) 87 Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. ( 1.24 ) 88 5 / 6 A Switch ( 1.24.1 ) 89 3 Pin 5 / 6 A Socket Outlet ( 1.24.4 ) 90 15 / 16 A Switch 91 6 Pin 15 / 16 A Socket Outlet 92 Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper / Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb / Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall , Making Good The Damages, Colour Washing Etc. As Required ( 90.11.1.10 ) 93 4 Way ( 8+12 ) - Three Phase Double Cover ( Ip 42 / 43 ) 94 Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, “C” Ncurve, Miniature Circuit Breaker Suitable For Inductive Load Of Nfollowing Poles In The Existing Mcb Db Complete With Nconnections, Testing And Commissioning Etc. As Required. N 95 Single Pole ( 2.10.1 ) 96 Supplying And Fixing Following Rating, Four Pole, 415 V, Isolator In Nthe Existing Mcb Db Complete With Connections, Testing And Ncommissioning Etc. As Required. 97 63 A ( 2.13.2 ) 98 Supplying And Fixing Following Rating, Four Pole, ( Three Phase Nand Neutral ) , 415 V, Residual Current Circuit Breaker ( Rccb ) , Nhaving A Sensitivity Current 30 Ma In The Existing Mcb Db Ncomplete With Connections, Testing And Commissioning Etc. As Nrequired. 99 40A ( 2.15.2 ) 100 Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal / Coke And Salt As Required. ( 5.4 ) 101 Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring / Cables And Giving Connection As Required.Standard Make And Isi Marked 102 3.15 Mm Copper Conductor ( 10 Swg ) ( Lmr ) 103 Supply And Installation Of 9W Led Bulb. ( Make: Philips / Crompton / Equivalent ) Standard Make And Isi Marked ( Lmr ) 104 Led Tube Light Fitting Suitable For Single 20 W T5 Lamp With Lamp Nholder, Apf Electronic Ballest Suitable For Continious Operation With Thd N<10%, Power Factor >0.98, Rohs Compliant, Duly Wired Up For Use On N230 V Ac Supply Without Fluorescent Tubes. The Fittings Shall Be Made Nfrom Crca Ms Sheet Of Minimum Thickness 0.50 Mm Nominal Thickness Ninside And Outside. ( Make: Philips / Crompton / Equivalent ) Standard Make And Isi Marked ( Lmr ) 105 Supply And Installation 1200 Mm Sweep- 5 Star Rated Ceiling Fan, Complete With 300Mm Down Nrod, Canopies, Shackles And Blades And Resistance Type Regulator Nworking On 230 / 240V Single Phase A / Cstandard Make And Isi Marked ( Lmr ) N 106 Supplying And Fixing Brass Batten / Angle Holder Including Nconnections Etc. As Required.
BRR : 9468301
Tender For Upgradation Of Indoor/Outdoor Stadium And Sports Facilities At Bundelkhand University Jhansi (U.P) - 1 Upgradation of Indoor/Outdoor Stadium and Sports Facilities at Bundelkhand University Jhansi (U.P) 2 RUNNING TRACK 3 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres. [DSR 16.1] 4 Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. (DSR-4.1.8) 5 First Class brick work in 1:4 cement and coarse sand of 2.25 F.M. mortar in foundation and plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work. (1:6 cement & coarse sand). M-150 Class Brick work. 6 15 mm cement plaster on rough side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand) F.M. 2.25. 7 25mm thick 1:2:4 plain cement concrete floor (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement.DSR-11.3.1 8 Construction of granular sub-base by providing close graded Materialconforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge.With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30,(DSR-16.78.1) 9 Supplying & Laying, spreading and compacting Red bajri of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density . (DSR 16.3.8+16.4) 10 Filling of carted earth. 11 Modular Grating for Drain made on White ABS (UV Stabilised) suitable for Reversible curves also. Individual Units Slotted Togather to Form A continous Run. Grating Width 350-400 mm (MR) 12 Providing & Laying 150mm dia PVC pipe 6 Kg pressure (For drainage of water of drain from running track/ inside area of track toward outside of track. 13 Line Marking 14 VISITOR PAVILION 15 Excavation in foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. 16 Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 stone ballast 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. 17 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 18 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) 19 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). 20 P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. 21 Class M-150 brick work in 1:4 cement coarse sandmortar insuperstructure including supply of all materials, labour, tools and plants etc. required for proper completion of the work. 22 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 coarsesand. 23 Earth filling. 24 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble 25 Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. 26 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). 27 Providing and applying white cement based putty of average thickness 1 mm, of approved brand &anufacturer, over the plastered wall surface to prepare the surface even & smooth complete. 28 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) 29 Centering and shuttering including strutting, propping etc. and removal of form for (a) Foundations, footings, bases of columns, etc. for mass concrete 30 (b) Columns, Pillars, Piers, Abutments, Posts and Struts 31 (b) Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick 32 REPAIR WORK OF INDOOR STADIUM 33 Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. With cement mortar 1:4 (1cement: 4 coarse sand) 34 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete 35 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 36 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 37 Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross T of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main T at 600 mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600 mm & size 24x25 mm made of 0.30 mm thick (min.) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm & wall angle of size 24x24x0.3 mm & laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. 12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16mm thick fire retardant PVC film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit. 38 Providing and fixing aluminium work for doors, windows, ventilators and partitions witth extruded built up standard tubular sections/appropriate z sections and other sections of approved make conforming to IS 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctins, i.e. att top, bottom and sides with required. Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) 39 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architecttural drawings and the directins of engineer-in-charge (Cost of aluminium snap beadingg shall be paid in basic item). With float glass panes of 8 mm thicness 40 Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture 41 Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture 42 Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer- in-charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding. 43 STAGE LIGHTING SYSTEM 44 Supply Installation, Testing and Commissioning of Profiles Light,Profile spot for sharp focusing, Four edge with Iris shutter. Black finish Color, Model : PH 2550 Make : A K Electrical 45 Supply Installation, Testing and Commissioning of Par 64 Lights ,Powerful Light for Stage, 1000 watt Power,With wide medium and Narrow Beam, Matt Black or Chrome Finish Light.,Length 43 cms. Width 28 cms. Height 25 cms.Model : PAR 64 Make : Sai Stage Products 46 Supply Installation, Testing and Commissioning of Fresnel Lights, Soft edge Spot Light for Stage, Fresnel Lens 150 mm., with GX 9.5 Base for T-11 type Lamps and Barndoor. Black finish Color,Length 34 cms. Width 30 cms. Height 31 cms. Model : FT-1001, Make : Sai Stage Products 47 Supply, Installation, Testing and Commissioning of PC Light, A Multi Purpose Light., Single Lens 145 mm condenser.with GX 9.5 Base for T-11 type Lamps. Black finish Colour,Length 40 cms. Width 30 cms. Height 35 cms. Weight 9 Kgs.approx, Model : PT1001, Make : Sai Stage Products 48 Supply, Installation, Testing and Commissioning of Halogen Light, Stage Filler Light,with1000 watt Halogen lamp, Model : 100-H, Make : Sai Stage Products 49 Supply, Installation, Testing and Commissioning of Halogen Cyclorama Light,1000 Watt halogen Cyclorama Light,Used to light up background, Matt Black Finish.Length 25 cms. Width 35 cms. Height 32 cms. Weight 4.5 Kgs Model : CFH-100, Make : Sai Stage Products 50 Supply, Installation, Testing and Commissioning of Dimmer Board, 12x4 KW, Wall mount with 12x4 way Patch Panel built in, Model : DMW 2012, Make : Sai Stage Products 51 Supply, Installation, Testing and Commissioning of Light Mixer Controller, Model : LSCMake : Maxim 52 Supply, Installation, Testing and Commissioning of 50mm dia MS Bar for Lights 45 ft. long 53 Supply, Installation, Testing and Commissioning of Side Ladders 6x2 of MS Tube 2x1 for lights between wings 54 Supply, Installation, Testing and Commissioning of C Clamps for 50mm MS Pipe 55 Supply, Installation, Testing and Commissioning of Safety chains for Lights 56 Supply, Installation, Testing and Commissioning of Power wire1.5 sq.mm, 3 core cable in PVC conduit to be done at site with sockets & tops for lights 57 SOUND SYSTEM 58 BoschElectrovoice Speaker 400watt 2 waypassive 60 degree x 40 degree. Nominal impedance 8Ohmswithbuilt in crossover 99 dBsensitivity , 131 dB maxSPL, angledinputpanel Maxwattage 1600 watt Peak Model G115 59 Bosch Electro Voice350 watt cont. / 1400 watt P 18 sub woofer complete withback bonegrill having 100 dB sensitivity, 131.5 dB SPL with extremely lowdistortion with high sensitivity, rextangularenclosure omnidirectional rearmountedcasterswith luggagestyle handle Model Force I sub 60 Electro Voice 2wayfullrange 200 Watt Speaker Driver protectedcircuit, Trapezoidalshape, Freqresponse : 60to20000 Hz MaxSPL 121 dB, Longtermpowerhandling200 Watts , LFtransducer 8”, throatdiameter 1.25”andnominal impedance 8 Ohms equippedwithfourpindetachable speakonconnectors Model SL 8.2 61 Bosch Electro VoiceAmplifierwithdynamic capability having ultralowhum&noisewithdistortion< 0.05%.2 x 800 watt powerat 4 Ohms& 2 x 1400 watts at 2 Ohms.Freq 10 to 40000 Hz Slewrate 27 V/ micro sec, inputbalanced impedance 20 K Ohms S/Nratio > 109 dB Model Q99 62 BoschDynacord heavy duty high performance Amplifier 2 channel Distortion < 1%, Maxpower 2 x 450 Watts at 4 Ohms, Slewrate 28 V/micro sec, crosstalk < -75 dB, Freqresponse10 to 40000 Hz Balancedinputimpedance 20 K Ohms. S/N Ratio 104 dB. Model PCL 1245 63 Bosch Electro Voice Digital signal processor having 2 in 6 outfor loudspeakermanagement optimisation Model DC-One 64 Boschdigitalfeedbacksuppressorcumaudioprocessor workingon24bitAlgothermsoftware 65 BoschDeskstandpremiumgooseneckmike undirectional condensor, ON/ Off slidingswitch, sensitivity 25mVolts/pascal Freq 100 to 16000 Hz, output impedance< 200 Ohms distortion < 0.6 % currentconsumption <8 mA 66 Boschdynamichandheldmikeunidirectionalsenstive forspeech&conferenceLBC 2900 67 Bosch EV makeHandheldwiredcardiodemicrophoneforgeneralapplicationshaving freq response 50 to 18000 Hz Open Circuit voltage 2.8 mv / Pascal, bodyof Die cast Zinc cobaltfinish with 600 ohmsimpedance Co 5 68 Micro VHFCordless handheldmicrophonewithprogrammablefacility formorethan1000frequencies in25 KHzsteps & operates in 24 MHz band width in the UHF portion, Backlit LCD display, 1 touch auto clear scan, Freq 50 -15000 HZ, PLL Synthesized 69 16channelmixerwithbassandtrebleinallchannelswithphantompoweronallchannelshaving3 bandgraphicequalizerandcompletewith6 compressors, HPF, high qualitymikepre amp, illuminatedchannel ON switches 10 mikeinputs, 4 stereo, 2 Aux send, 1 effect send, 6 buses & 12 seg Led indicatorYamaha 70 Standfloorfor Microphone GS 71 Floor standfoldableHalf GS 72 Tablestand GS 73 Wiringwith 2core shieldedmicrophone cable in pre laid pipes 74 Wiringwith2core 2.5 mm copper multistrand speaker cable 75 Makingofmike /Input pointsBoxes onstage with connector 76 Equipment Rack - 32 U 77 Earth Work in Laveling, Dressing, Making huts, Making Approch road for Material and other Contengency Work in favour of R&P UPGRADATION OF INDOOR / OUTDOOR STADIUM & SPORTS FACILITIES AT BUNDELKHNAD UNIVERSITY,DISTRICT :-JHANSI (U.P.)by Direction of Enginear in charge. All work should be done including labour & Material Costin. and also Payment done after making PCR & Other Official Paper work. 78 GST Extra as per applicable
BRR : 8979082
Tender For Electrical Work - &P 2 Fire Fighting Work Fire Pumps And Accessories: Supplying, Installation, Testingand Commissioningof Electric Driven Main Fire Pump Suitablefor Automatic Operationandconsistingoffollowing, Completeinall Respects, As Required :A ) Horizontal Type, Multistage, Centrifugal, Split Casing Pump Of Cast Iron Body & Bronze Impeller With Stainless Steel Shaft, Mechanical Seal Conforming To Is 1520.B ) Suitable Hp Squirrel Cage Induction Motor, Tefc, Synchronousspeed1500rpm, Suitableforoperation On415volts, 3Phase50hz, Acsupplywithip55 Protectionforenclosure, Horizontalfootmountedtype With Class-F Insulation, Conforming To Is-325.C ) Suitable Hp Squirrel Cage Induction Motor, Tefc, Synchronousspeed1500rpm, Suitableforoperation On415volts, 3Phase50hz, Acsupplywithip55 Protectionforenclosure, Horizontalfootmountedtype With Class-F Insulation, Conforming To Is-325.D ) M.S. Fabricated Common Base Plate, Coupling, Coupling Guard, Foundation Bolts Etc. As Required. E ) Suitablecementconcretefoundationdulyplastered With Anti Vibration Pads. F ) 2850 Lpm At 70 M Headnote: * The Head Of The Pump Is Selected In A Manner Soastogivea Minimum 3.5Kgf / Cm 2 Pressureat The Highest / Farthest Point. 3 Supplying, Installation, Testingandcommissioningof Diesel Engine Driven Main Fire Pump Suitable For Automatic Operation And Consisting Of Following, Complete In All Respects, As Required : ( Diesel Driven Pump ) A ) Horizontal Type, Multistage, Centrifugal Pump Of Cast Of Iron Body And Bronze Impeller With Stainless Steel Shaft, Mechanical Seal Conforming To Is 1520.B ) Suitablehp, 1500Rpmwatercooledwithradiator, Diesel Engine Conforming To Relevant Is Standard Completewithautostartingmechanism, 12 / 24Volts Electricstartingequipment, Dieseltank, Exhaustpipe Extended Upto 10 M Outside Pump House Duly Insulated With 50 Mm Thick Glass Wool With 1.0 Mm Thick Aluminium Sheet Cladding, Residential Silencer, Instruments And Protection As Per Standard Specification, Stop Solenoid For Auto Stop In The Event Of Fault With Audio Indications, Painted With Post Office Red Colour Etc. As Required. C ) M.S Fabricated, Common Base Plate, Coupling, Coupling Guard, Foundation Bolts Etc. As Required. D ) Suitablecementconcretefoundationdulyplastered And With Anti Vibration Pads.2850 Lpm At 70 M Headnote: * The Head Of The Pump Is Selected In A Manner Soastogivea Minimum 3.5Kgf / Cm 2 Pressureat The Highest / Farthest Point. 4 Supplying, Installation, Testingandcommissioningof Electricdrivenpressurisationpumpsuitablefor Automaticoperationandconsistingoffollowing, Complete In All Respects, As Required : ( Jockey Pump ) A ) .Horizontaltype, Multistage, Centrifugalpumpofcast Iron Body And Bronze Impeller With Stainless Steel Shaft, Mechanical Seal Conforming To Is : 1520. B ) .Suitablehpsquirellcageinductionmotortefctype Suitableforoperationon415volts, 3Phase50hz Ac Supply With Ip 55 Class Of Protection For Enclosure, Horizontalfootmountedtypewithclass-FInsulation, Conforming To Is : 325. C ) .M.S.Fabricated Common Base Plate, Coupling, Coupling Guard, Foundation Bolts Etc. As Required.D ) .Suitablecementconcretefoundationdulyplastered And With Anti Vibration Pads.180 Lpm At 70 M Head 5 Control Panels: Fabrication, Supply, Insallation Testing & Commissioning Of Electrical Control Panel Of Cubical Construction, Floor Mounted Type, Fabricated Out Of 2Mm Thick Crca Sheet, Compartmentalisedwithhingedlockabledoors, Dustandverminproof, Powdercoatedofapproved Shade After 7 Tank Treatment Process, Cable Alley, Inter-Connection With Suitable Sizecopperconductor Cable / Solidcopper Strip, Havingswitchgears And Accessories, Mountings And Internal Wiring, Earth Terminals, Numbering Etc. Complete In All Respect, Suitableformainfirepump, Pressurisationpump& Dieselpumpsetcompleteaspercpwdspecification Withfollowingincomingandoutgoings, Suitablefor Operationon415v, 3Phase, 50Hzacsupplywith Enclosure Protection Class Ip 42 As Required :Incomings:A ) 630A, 50Ka4 Pole Mccb, Ics=100% Icu Rating Digital Voltmeter 0-500V With Selector Switch Ammeter ( 0-630 A ) With Selector Swtich & Cts Etc.B ) Ledtyperybphaseindicatinglamps, On, Off, Trip Indicating Lampsset Of Copperbus Bar 800Ampsoutgoings: Main Fire Pump :200Amp, 50Katpnmccb, Ics=100%Icu, Withfully Automatic Star / Delta Starter Suitable For 75 Hp Pump With Overloadprotection, Currentsensingtypesinglephase Preventorcompletewithallacceessoriesandinternal Wiringrequiredforautomaticoperation, Selectorswitch For Local / Remote, Auto / Manual / Off Operation. - 2 Setsjockey Pump:100 Amp, 50Ka Tpn Mccb, Ics=100% Icu, With Suitable Hp Fully Automatic Star / Delta Starter With Overload Protection, Currentsensingtypesinglephasepreventor Complete With All Acceessories And Internal Wiring Requiredforautomaticoperation, Selector Switchfor Local / Remote, Auto / Manual / Off Operation. - 2 Setsdiesel Engine Controla ) Control For Diesel Engine Comprising - Automatic / Manualselctorswitch&3Attemptsstarting Device, Timersandrelaysasrequired, Pushbuttons, Start / Stop In Manual Modeb ) Indicatinglampforhigh / Lowlub.Oilpressure, High Water Temp And Engine On Indicationc ) Batterychargersuitbalefor12v / 24Vdcwithboost And Trickle Selector Switch, 0-30 V Dc Volt Meter, And 020 A Dc Ammeter All Standard Relays And Accessories For Automatic Operation Of Diesel Engine.System Controller: Designing, Supply, Installation, Testingand Commissioning Of System Controller To Control Operation Of Main Electric Fire Pump, Diesel Pump, Pressurization Pump, Terrace Pump In Sequence As Per Specification Consisting Of Relays, Timers. Sensors, Annunciation Windowforfaultindication, Complete As Per Specification 6 Providinglaying, Testing&CommissioningofCClass Heavydutymspipeconformingtois1239 / 3589I / C Fittingslikeelbows, Tees, Flanges, Tapers, Nutsbolts, Gasketsetc.Ingroundincludingwelding, Excavation& Providingcementconcreteblocksassupports, Anticorrosivetreatmentwithcoaltar / Asphalttapeasper Is10221, Refillingthetrenchetc.Offollowingsizes Complete As Required. 200 Mm. Dia ( Wall Thickness = 6.3 Mm ) 7 150 Mm. Dia 8 Providing, Laying, Testing&Commissioningof CClass Heavydutymspipeconformingtois3589 / Is1239 Includingwelding, Fittingslikeelbows, Tees, Flanges, Tapers, Nuts Bolts, Gaskets Etc. And Fixing The Pipe On The Wall / Ceiling With Suitable Clamp / Support Frame And Painting With Two Or More Coats Of Synthetic Enamel Paint Of Required Shade Complete As Required : 25 Mm Dia 9 32 Mm Dia 10 40 Mm Dia 11 50 Mm Dia 12 65 Mm Dia 13 80 Mm Dia 14 100 Mm Dia 15 150 Mm Dia 16 Providing, Laying, Testing&CommissioningofBClass Heavydutyg.I.Pipeconformingtois1239including Welding, Fittings Like Elbows, Tees, Flanges, Tapers, Nuts, Bolts, Gaskets Etc. And Fixing The Pipe On The Wall / Ceiling With Suitable Clamp / Support Frame And Painting With Two Ormorecoatsofsyntheticenamelpaintofrequired Shade Complete As Required: 25 Mm 17 32 Mm 18 40 Mm 19 50 Mm 20 65 Mm 21 80 Mm 22 100 Mm 23 150 Mm 24 Supplyingandfixingsingleheadedinternalhydrant Valve With Instantaneous Gunmetal / Stainless Steel Coupling Of 63 Mm Dia With Cast Iron Wheelisi Marked Conformingtois5290 ( Type-A ) Withblank Gunmetal / Stainless Steel Cap And Chain As Required :Single Headed Gunmetal 25 Supplying And Fixing Single Headed External Yard Hydrant Valve With 1 No. 63 Mm Dia Instantaneous Fm Gunmetal / Stainlesssteel Couplingand Cast Iron Wheel, Isimarked, Conformingtois5290 ( Typea ) Withblank Gunmetal / Stainless Steel Cap And Chain As Required :Single Headed Gunmetal 26 Supplying, Fixing, Testing And Commissioning Of Butterfly Valve Of Pn 1.6 Rating With Bronze / Gunmetal Seat Duly Isi Markedcompletewithnuts, Bolts, Washers, Gaskets Conforming To Is 13095 Of Following Sizes As Required :80 Mm Dia 27 100 Mm Dia 28 150 Mm Dia 29 Supplying, Fixing, Testing&Commissioningofdouble Flangedsluicevalveofratingpn1.6Withnonrising Spindle, Bronze / Gunmetalseat, Isimarkedcomplete With Nuts, Bolts, Washers, Gaskets And Conforming To Is 780 Of Following Sizes As Required : 80Mm Dia 30 100Mm Dia 31 150Mm Dia 32 200Mm Dia 33 250Mm Dia 34 Supplyingandfixingorificeplatemadeoutof6mm Thick Stainless Steel ( Grade 304 ) With Orifice Of Required Sizetobefitted Betweenflange&Landingvalveof Externalandinternalhydrantstoreducepressureat The Outlettothe Levelof 3.5Kg / Cm2 Complete As Required. 35 Providing, Installation, Testingandcommissioningof Non-Returnvalveoffollowingsizesconfirmingtois: 5312 Complete With Rubber Gasket, Gi Bolts, Nuts, Washers Etc.As Required.100Mm Dia 36 150Mm Dia 37 200Mm Dia 38 Providing, Installation, Testingandcommissioningof Stainlesssteely-Strainerfabricatedoutof1.6Mm Thickstainlesssteel, Grade304, Sheetwith3mmdia Holes With Stainless Steel Flange.150Mm Dia 39 200Mm Dia 40 Supplying And Fixing 63 Mm Dia, 15 M Long Rrl Hose Pipewith63mmdiamaleandfemalecouplingsduly Boundwithgiwire, Rivetsetc.Conformingtois636 ( Type-A ) As Required : Gun Metal 41 Supplying Andfixing First-Aidhosereelwithms Constructionspraypaintedinpostofficered, Conformingtois884completewiththefollowingas Required. A ) . 20Mmnominalinternaldiawaterhosethermoplastic ( Textile Reinforced ) Type -2 As Per Is: 12585 B ) .20Mmnominalinternaldiagunmetalglobevalve& Nozzle. C ) .Drum And Brackets For Fixing The Equipmets On Wall.D ) .Connections From Riser With 25 Mm Dia Stop Gun Metal Valve & M.S. Pipe And Socket. E ) .40 M 42 Supplying & Fixing 63 Mm Dia Gun Metal Short Branch Pipe With 20 Mm Nominal Internal Diameter Sizenozzle Conforming To Is 903 Suitable For Instantaneous Connection To Interconnect Hose Pipe Coupling As Required : Gun Metal 43 Supplyingandfixingoffirebrigadeconnectionof Cast Iron Body With Gun Metal Male Instantaneous Inlet Couplingscompletewithcapandchainasreqd.For Suitabledia Ms Pipe Connectionconforming To Is 904 As Required :2 Way-100 Mm Dia M.S. Pipe 44 4 Way - 150 Mm Dia M.S. Pipe 45 3 Way - 150 Mm Dia M.S. Pipe 46 Supplying And Fixing Air Vessel Made Of 250 Mm Dia, 8 Mm Thick Ms Sheet, 1200 Mm In Height With Air Release Valveontopandflangedconnectiontoriser, Drain Arrangementwith25mmdiagunmetalwheelvalve Withrequiredaccessories, Pressuregaugeand Paintingwith Synthetic Enamel Paint Of Approved Shade As Required. 47 Providing, Fixing, Testing & Commissioning Of 15Mm Dia Quartzoidbulbtypesprinklersofrating68degree Centigrade With Required Accessories :Pendent Sprinkler 48 Upright Sprinkler 49 Horizontal Side Wall Sprinkler 50 Concealed Sprinkler 51 Providing & Fixing Of Pressure Switch In M.S. Pipe Line Including Connection Etc. As Required. 52 Providing& Fixingflowswitchinfollowingsizesm.S. Pipe Including Connection Etc As Required. 53 100Mm Dia 54 150Mm Dia 55 Providing, Fixing, Testing & Commissioning Of Installationcontrolvalveofcastironbody, Brass / Bronzeworking Partscomprisingofwater Motor Alarm, Bronzeseatclapper, Clapperarmand Hydraulicallydrivenmechanicalgongbelltosound Continuousalarmwhenthewetriser / Sprinklersystem Activates, Pressuregauges, Emergencyreleases, Strainer, Pressureswitch, Cockvalvecompletewith Drainvalveandbypass, Testcontrolbox, Ballvalves, Ms Pipe Of Required Size, Flanges, Orifice Plate, Gasket Etc Of Follwing Sizes Asrequired : 150Mm Dia 56 Supplying, Installation, Testing & Commissioning Of Sprinklerflexiblepipe ( Ullisted ) Ofstainlesssteel Complete With 15 Npt On Reducer Thread With Maximum Working Pressure Of 175 Psi Test Pressure Of 875Psi ( Burst ) Withbranchline ( Inlet ) 25Mmnpt Malethreadtosprinklerhead ( Outlet ) 15Mmnpt Femalethreadwithreducer, Nipple, 2Sidebrackets, Center Bracket, Stockbar Of Following Sizes Complete As Required.700Mm 57 1000Mm 58 1200Mm 59 1500Mm 60 Providing And Fixing In Position The Industrial Type Pressure Gauges With Gun Metal / Brass Valves Complete As Required ( E&M ) 61 Providing And Fixing Ms Cabinet ( Size 750X600x250 Mm ) Fabricated From 16 Gauge Ms Sheet With Full Front Glass Door & Locking Arrangement For Pad Lockwith Suitable Shelves For Keeping 25 Nos. Spare Sprinklers & One No. Spanner Properly Fixed In Shelves. Cabinet Shall Be Painted With Enamel Paint Of Approved Shade. ( Cost Shall Include 20 Nos. Spare Sprinklers ( 5 Nos Side Wall 20Nos Pendent, One No. Spanner And 5 Rolls Of Teflon Tape ) . Note: All Valves Shall Be Of Pn16 Rating 62 Portable Fire Extinguishers: Providing & Fixing Of Isi Marked ( Is:15683 ) Portable Fire Extinguisher, Carbondioxide Type Flat Base Including Valve, Discharge Hose Of Not Less Than 10 Mm Dia. 1 M Long & Complete In All Respects Including Initial Fill With Co2 Gas Confirming To Is:307-1966 Filled To A Filling Ratio Of Not More Than 0.667 Of Not More Than 0.667 And Wall Suspension Bracket Capacity 4.5 Kg 63 6 Kg. Abc Powder Type Fire Extinguishers Are Manufactured And Marked To Indian Standard Is: 15683. Suitable First Aid Appliance For Fighting Fires In Class A, B & C Fire That Is Wood, Textile, Flammable Liquids & Gases. 64 Providing And Fixing Mechanical Foam Type Fire Extingushers Consisting Of Welded M.S. Trolley Mounted Cylindrical Body, Squeeze Lever Discharge Valve Fitted With Pressure Discharge Hose, Discharge Nozzle, Trolley Etc., Isi Marked As Per Is:Is:13386 Finished Externally With Red Enamel Paint.Capacity 50 Lit ( D.G.Room ) 65 Providing And Fixing Carbon-Di-Oxide Fire Extingushers Trolley Mounted With All Accessories Internal Discharge Tube, High Pressure Discharge Hose, Discharge Nozzle, Isi Marked As Per Is:2878 Finished Externally With Red Enamel Paint. Capacity 22.5 Kg. 66 Boq-D: Plumbing Pump & Equipmentswater Supply, Drainage, Pumps & Equipment :Providingand Fixing Centralized Water Level Controller Cum Indicator System, As Per The Following Details:Centralised Plc Control Panel : Along With Touch-Screen Display Board ( Min. 8 Diag. Size ) Along With All Accessories For Complete Controls & Indication. Panel Shall Be Made Out Of Crca Sheet Min. 2Mm Thick Having Necessary Interlocks, I / OS, Required Number Of Repeater Amplifiers, All Audio-Visual Alarms As Required Specifications As Listed Below. An Emergency Stop Push Button Shall Be Provided In The Panel. The Panel Shall Have Modbus Compatibility For Seamless Bms / Bas Integration And Shall Be Of Approved Make. The Complete System Control Matrix, Wiring Diagram, SldS And Technical Details Shall Be Submitted By The Vendor And Gotten Approved Before Commencement Of Execution Of Works. Water Level Indicators Cum Controllers :Working On Hydrostatic Pressure Measurement Principle Made Of Stainless Steel For Installation On Storage Tanks, And Capable Of Providnig 4 To 20 Ma Analog Signal Compatiblewith Plc Signal Inputs And Completeas Per Working Requirements For Details Of Equipment Below. All Control Outputs To Mcc Panel Shall Be Included As Per Requierments. A ) .Fire Static Underground Tanksb ) .Real-Time Water Level Indication Monitoring 67 V. Low Level Audio-Visual Alarm At Less Than 25% Total Capacity.Raw Water Underground Tanksreal-Time Water Level Indication Monitoring V. Low Level Audio-Visual Alarm At Less Than 30% Total Capacity. V. High Level Audio-Visual Alarm At More Than 100% Total Capacity.Auto Cut-In Of Tubewell Pumps At 35%Auto Cut-Out Of Tubewell Pumps At 95% 68 Auto Cut-Out Of Raw Water Pumps At 35%Domestic Water Underground Tanks Real-Time Water Level Indication Monitoring V. Low Level Audio-Visual Alarm At Less Than 30% Total Capacity. V. High Level Audio-Visual Alarm At More Than 100% Total Capacity. Auto Cut-In Of Raw Water Pumps At 35% 69 Auto Cut-Out Of Domestic Water Pumps At 35% Flushing Water Underground Tanks At Stpreal-Time Water Level Indication Monitoringv. Low Level Audio-Visual Alarm At Less Than 30% Total Capacity.V. High Level Audio-Visual Alarm At More Than 100% Total Capacity.Auto Cut-In Of Raw Water Pumps ( From Stp ) At 35% 70 Auto Cut-Out Of Flushing Water Pumps At 35% Domestic Water Overhead Tanksreal-Time Water Level Indication Monitoring V. Low Level Audio-Visual Alarm At Less Than 30% Total Capacity. 71 V. High Level Audio-Visual Alarm At More Than 100% Total Capacity. Flushing Water Overhead Tanksreal-Time Water Level Indication Monitoring V. Low Level Audio-Visual Alarm At Less Than 30% Total Capacity. 72 V. High Level Audio-Visual Alarm At More Than 100% Total Capacity. 73 Providing Complete Testing Kit With All Chemicals Complete Suitable For Conducting Test On Water Quality.The Test Kit Shall Be Suitable To Measure Tds, Ph, Hardness, Iron Content And Other Parameters 74 Hydro-Pneumatic Pumping System For Domestic Supply To Fixture ( Toilet Kitchen ) : Providing, Fixing And Testing Of Packaged Type Skid Mounted Hydropneumatic System With Variable Frequency Drive Type Comprising Of : ( I ) Vertical, Inline Multistage Centrifugal Pumping Set With Stainless Steel Ss-304Stage Casing And Ss-304 Impellers With Stainless Steel Ss-304 Shaft As Per Iecstandards And Gjl250 Cast Iron Suction& Discharge Casing, Connected To Tefc Ventilated Induction Motor Of2 Pole, 2900Rpm, Suitable For 400 / 440 Volts, 3 Phase, 50 Hz A.C. Supply. ( Ii ) Pressure Vessel Of Non Corrosivefrp Composite Construction Lined With Nsf And / Or Fda Listed Material, Likehigh Density Polyethylene With Fully Replaceable Polyurethane. Air Cell Burstpressure Of Minimum Of 5 Times The Vessel Operating Pressure And Cycle Tested For 2, 50, 000 Cycles. ( Iii ) Control Panel With Programmable Logic Controller ( Plc ) For Cyclic Operation Of Pumps + Variable Frequency Drive. The Pump Workingsequence Should Change After Every Operation.Contractor Overload Relays And Mcbs Should Confirm To Iec 898 – 1995 / Specifications. Blinking Indications For Pumps Start, Trip, Low Level Trip, Health Supply Should Be Provided In The Panel Along With The Ammeter& Voltmeter. Control Panel Should Also Consist Of Cooling Fan. ( Iv ) Pressure Switches Bellowtypefittedwithmicro Switch And Having Maximum Pressure And Differentialscaleshould Confirming Bs-6134 Standards And Ip55 Protection Class. ( V ) All Required Ball Valves, Non-Return Valves, Flexible Connectors Etc. And All Required Accessories, Heavy Duty S.S 316 Manifold To Make The System Completely Operational As A Skid Mounted System. Ball Valves Tobe Used Should Be Hot Pressed Brass Ot-58Withstainless Steelballand P.T.F.Eseal And O-Ring. Nrvs To Be Used Shouldbewithspringsando-Ring Arrangement. ( Vendor To Submit Performance Curves And Technical Catalog Of The Proposed Model For Review & Information ) Complete Manifold System Shall Be Factory Aasembled & Totally Mounted On A Common Base Frame With Following Duties:Note: Contractor To Note That The Suction Header Is Required To Have Inlet Connection From The Puddle Flange @ Water Tanks And To The Pump Suction. Provision Of Delivery Header Is Required To Have Outlet Connection From The Pumps. Suitable Outlet Flanges From The Delivery Mainfold / Header Shall Be Provided As Required.A.For Domestic Water Supply For Club & Benquet Hall: No. Ofpumps :1 ( 1 Working +1 Standby ) Capacity: 350 Lpm Each Pump Head: 55 Meters Apx. Hp ( Motors ) : 3 Hp Location : Plumbing Plant Room 75 For Flushing Water Relift Pump :No. Ofpumps :1 ( 1 Working +1 Standby ) Capacity: 250 Lpm Each Pump Head: 55 Metersapx. Hp ( Motors ) : 2 Hplocation : Stp Plant Room 76 Garden Hydrents & Floor Washing Relift Pump:Providingand Fixing Vertical, Inline Multistage Centrifugalpumpingset ( Complete Manufactured Skid-Mounted Arrangement With Manifold And Accessories ) Withstainlesssteelss-304Stage Casingandss-304Impellerswith Stainless Steel Shaft As Per Iec Standards And Gjl250 Cast Iron Suction & Discharge Casing, Connected To Tefc Ventilated Induction Motor Of 2 Pole, 2900 Rpm, Suitablefor 400 / 440 Volts, 3 Phase, 50 Hz A.C. Supply With Pressure Gauge And With Gunmetal Isolationcocks, Vibrationelimination Pads Etc. Complete With Base And Frame, Nuts And Boltsandnecessary Rcc Foundations As Per Requirementasper Instructionsandpumpshallhave Following Duty:No. Ofpumps :2 ( 1 Working +1 Standby ) Capacity: 200 Lpm Each Pumphead: 45 Metersapx. Hp ( Motors ) : 4 Hplocation : Stp Plant Room 77 Supply, Installation, Testing & Commissioning Of Continuous Duty Submersible Centrifugal Non-Clogging Drainage Pumps Of Efficiency Of Approved Make Complete With 3 Phase Motor With All Necessary Protection And Mechanical Seal Etc. Complete With All Ancillaries Including Float Type Level Controllers, Electrical Control Panels Fabricatd From 14 Gauge Crca Sheet Volt Meter Ammeter With Selector Switch, Tpmcb, 5 Va Cl : Cts, Phase Indicating Lamps Protected By 2 Amp Sp Mcb, Dol Starter, Necessary Wiring, Cable Alleys, Earthing, Interlocking, Starter With Automatic Float Type Level Controller, Providion Of High Level Alarm, Sequence Timer, Potential Free Contact To Starter For Connection To Bas, Both Pumps May Run Simultaneously At Pre Determind Level. ( 1 Working + 1 Standby ) Vendor To Submit Proposed Pump Model With Duty Curve.A ) . For Wtp & Stp Plant Room Drainage :Flow Rate : 450 Lpm Head : 15 Mtssolid Handling : 100 Mmlocation : Sump Of Basement Purpose : Plant Room & General Area Drainage Moc : Ss Body Ss Impeller & Shaft 78 B ) .For Basement Drainage : Flow Rate : 450 Lpm Head : 15 Mts Solid Handling : 100 Mmlocation : Sump Of Basement Purpose : Basement Area Drainage Moc : Ss Body Ss Impeller & Shaft 79 C ) .Manhole Cover For U.G Tanks And Sumps :Supplying And Fixing C.I. Cover Without Frame For Manholes :560Mm Diameter C.I Cover ( Heavy Duty ) The Weight Of The Cover To Be Not Less Than 108Kg. 80 F ) .Providing And Fixing Stainless Steel Ladder, Wall Mounted Of 4M Height ( App ) For Underground Tanks Complete With Flanged Ends And Inserts ( Removable Type ) Made Of 38Mm / 42Mm Dia 16 G S / S 304 Quality Pipe Made As Per International Quality Standards Of Approved Shape And Size With Non Skidding Stepsat 300Mm Vertical Spacing, Completeas Directed By The Engineer In Charge. 81 Water Treatment Plant: Providing & Fixing Vertical, Inline Multistage Centrifugalpumping Set ( Complete Manufactured Skid-Mounted Arrangement With Manifold And Accessories ) With Stainlesssteel Ss-304 Stage Casing And Ss-304 Impellers With Stainless Steel Shaft As Per Iec Standards And Gjl250 Cast Iron Suction & Discharge Casing, Connected To Tefc Ventilated Induction Motor Of 2 Pole, 2900 Rpm, Suitable For 400 / 440 Volts, 3 Phase, 50 Hz A.C. Supply With Pressure Gauge And With Gunmetal Isolation Cocks, Vibration Elimination Pads Etc. Complete With Base And Frame, Nuts And Bolts And Necessary Rcc Foundations As Per Requirement As Per Instructions And Pump Shall Have Following Duty:A ) .For Club Building Only : No. Ofpumps: 2 ( 1 Working + 1 Standby ) Flow Rate :150 Lpm Each Head : 30 Mtsrequired For : Filter Feed Pump In Plumbing Plant Room ( 1Working + 1Standby ) 82 Providing And Fixing Vertical Pressure Filter With Dual Media Filter ( Comprising Of 600Mm Bed Depth Of Graded Sand Gravel And 600Mm Bed Depth Of Anthracite ) Fabricated From High Performance M.S Plate Of Minimum 8Mm Thick For Shell & 10Mm Thickfor Dished Ends With Top And Bottom Flanged Openings Including Top And Bottom Hub And Lateral Distribution And Collection System Complete With Initial Charge Of Filter Media, Face Piping, Valves, Accessories, Painting, Testing And Commissioning Complete. ( Tested To 6 Kg / M2 ) Discharge : 150 Lpm Filtration Rate: 17500 Lit. / M2 / H Discharge : 150 Lpm Suggested Dia App.: 0.90 M 83 Activated Carbon Filter ( Domestic Water ) : Providing And Fixing Vertical Activated Carbon Filter Comprising Ofactivated Carbon Filter Media Fabricated From High Performance M.S Plate Of Minimum 8Mm Thick For Shell & 10Mm Thickfor Dished Ends With Top And Bottom Flanged Openings Including Top And Bottom Hub And Lateral Distribution And Collection System Complete With Initial Charge Of Filter Media, Face Piping, Valves, Accessories, Epoxy Painting, Testing And Commissioning Complete. ( Tested To 6 Kg / M2 ) Discharge :100 Lpm Filtration Rate: 15000 Lit. / M2 / H Suggested Dia App.: 0.60 M 84 Providing, Fixing, Testing & Commissioning Of Msep Water Softening Plant ( Suitable For 3 Kg / Sqcm Workingpressure ) Complete With Initial Charge With T-40 Na Resin, Multiport Valve With Built In Ejector For Controlling All Operations ) , Regeneration System And Hdpe Tank, Pressure Gauge At Inlet, Outlet And Back Wash ( Each With Isolation Cock ) , Valves, Fittings And Water Hardness Testing Kit & Associatedworks. Softener Shall Be Suitable For The Following Duty:Note:The Successful Contractor Will Have To Carry Out A Test Of Raw Water From All The Sources Of Water For The Commercial, Residential & Apartment At Their Own Cost From A Reputed Lab As Approved By The Engineer-In-Charge / Consultant. On The Basis Of These Results The Contractor Has To Submit His Shop Drawings, Design Calculations And Specifications Accordingly.Please Note That It Is Ultimately The Responsibility Of The Contractor To Provide Treated Water For Different Use As Per International Standard As Given In The Attached Guidelines. Raw Water Hardness: 500 Mg / Ltreated Water Hardness:100 Mg / L Regeneration Period:12 Hrs.Capacity : 100 Lpm 85 Supplying, Installing, Testing And Commissioning Of Dosing System ( For Domestic Water Treatment Plant ) Consisting Of One Hdpe Tank Of 100 Litres Capacity With A Positive Displacement Diphragm Dosing Pump Having Variable Flowrate Of 0-6 Lph. The Motor Shall Be Suitable For Operation At 240 V / Single Phase / 50 Hz. Supply. The Pump Shall Be Supplied Complete With Necessary Polypropylene Piping, Valves, Strainers, Low Level Switch Andinjection Fittings. The Pump Shall Be Speed & Stroke Control Asialmi / Equivalent Make. The Cost Shall Be Inclusive Of Providing Salt For The Testing And Operation Of System Before Handover To The Owner. 86 Plumbing Panel: Design, Manufacture, Assembly, Wiring, Testing At Works And Supply To Site Of Following Panels / Distribution Boards / Switch Boards. The Boards Shall Be Designed And Fabricated As Per General Specifications, Technical Details, Specifications And Notes As Part Of This Tender / Boq And Relevant Bis Codes. ( Any Load Veriation In System As Technical Document Of Manifactureno Cost Shall Be Paid Extra For System Requirments ) Ip Rating: Ip 54 Incomer:1 No. 250 A 25 Ka, 3P Mccb Of Motor Duty - Only Magnetic Release. ( Adjustable Magnetic Release Upto 250A Mccb Or Micro-Processor Based Release Above 250A Mccb ) .Incomer Metering & Indication: A ) .415V / V3 / 110V / V3ptS, Cast Resin Type, 3 Phase For Metering & Indications, Suitable Rated 6A, Tp Mpcb Of The Fault Withstand Capacity As Of The Panel On The Primary Side Of Pt & Suitable Rated 6A, Tp Mcb On The Secondary Side Of Pt.B ) .R, Y, B Phase Indication Lamps ( 110V ) Led Type C ) .Cast Resin Metering CtS For Each Phase Of Class-1 Accuracy & Of Suitable Burden & Ratio D ) .1 No. Digital Vaf + Pf Meter ( 110V ) ( *With / Without Rs 485 Port ) Bus Bars : 400A, Tp, Aluminium Bus Bars Of Electrolytic Grade With Heat Shrinkable Sleeves 25 Ka. Control Transformer & Control Circuiting For Starters / Contactors & Indication Lamps : A ) .1 No. 415V / 55-0-55Vcast Resin Dry Type Control Transformer Of Adequate Va Burden To Take Care Of Load Of All The Contactor Coils. ( Transformer With Primary Taps At ± 2.5%, ± 5%, 50 Hz, Centre Tap Earthed ) .B ) .Suitable Rated 6A, Dp, Mpcb Of The Fault Withstand Capacity As Of The Panel For Control Circuiting For Contactors Coils On The Primary Side Of Control Transformer & Suitable Rated 6A, Dp Mcb On The Secondary Side Of Control Transformer.C ) .110V Control Circuiting D ) .110V Control Supply Healthy Indication ( Led Type ) .Outgoings: A ) .Dol Starter Comprising The Following ( For Upto 2 Hp Motors ) For Raw Water Pumps / Treated Water Transfer Pump / Flushing Water Transfer Pump / Borewell / Soft Water Transfer Pump / For Pump Room Fresh Air Fan / For Pump Room Exhaust Air Fan:A ) . For 1Hp. ( 2 Nos. ) ( Chamical Dosingpump ) B ) .Type-2 Co-Ordinationc ) . 1 No. Suitable Rated Tp Mpcb, 10Ka, With Inbuilt O / L Relay & Inbuilt Spp Feature ( Site Adjustable ) D ) .Suitable Sized 3P Contactor With 2 No & 2 Nc Auxiliary Contactse ) . On / Off / Trip Indication Lamps ( 110V ) ( Led Type ) F ) .On / Off Push Buttons G ) Star-Delta Timerh.2 Pole A / M Selector Switch For Bms Application I ) .Suitable Rated Single Cast Resin Ct For Metering On Y Phase, Of Class-1 Accuracy & Of Suitable Burden & Ratio. J ) .Digital Ammeter K ) .On / Off-Trip / A / M Potential Free Contacts For Bmsl ) .Control Wiring Terminals For Auto Operation Through Potential Free Contacts Ofwater Tank Level Controllers.B ) .Dol Starter Comprising The Following ( For 3 Hp To 5 Hp Motors ) For Raw Water Pumps / Treated Water Transfer Pump / Flushing Water Transfer Pump / Borewell / Soft Water Transfer Pump / For Pump Room Fresh Air Fan / For Pump Room Exhaust Air Fan :A ) For 4 Hp. ( 2 Nos. ) ( For Pump Room Exhaust Air Fan ) B ) Type-2 Co-Ordination C ) 1 No. Suitable Rated Tp Mpcb, 25 Ka, With Inbuilt O / L Relay & Inbuilt Spp Feature ( Site Adjustable ) D ) Suitable Sized 3P Contactor With 2 No & 2 Nc Auxiliary Contactse ) On / Off / Trip Indication Lamps ( 110V ) ( Led Type ) F ) 2 Pole A / M Selector Switch For Bms Application G ) Suitable Rated Single Cast Resin Ct For Metering On Y Phase, Of Class-1 Accuracy And Of Suitable Burden & Ratioh ) Digital Ammeter With Inbuilt Selector Switch I ) Digital Ammeter J ) On / Off-Trip / A / M Potential Free Contacts For Bmsk ) Control Wiring Terminals For Auto Operation Through Potential Free Contacts Ofwater Tank Level Controllers.C ) .Dol Starter Comprising The Following ( For 7.5 Hp To 10 Hp Motors ) For Raw Water Pumps / Treated Water Transfer Pump / Flushing Water Transfer Pump / Borewell / Soft Water Transfer Pump / For Pump Room Fresh Air Fan / For Pump Room Exhaust Air Fan:A ) For 7.5Hp. ( 2 Nos. ) ( Raw Water / Filter Feedpump ) B ) . For 6 Hp. ( 2 Nos. ) ( Soft Water Reliftingpump ) C ) .Type-2 Co-Ordinationd ) .1 No. Suitable Rated Tp Mpcb, 10 Ka, With Inbuilt O / L Relay & Inbuilt Spp Feature ( Site Adjustable ) E ) .Suitable Sized 3P Contactor With 2 No & 2 Nc Auxiliary Contacts F ) .On / Off / Trip Indication Lamps ( 110V ) ( Led Type ) G ) .On / Off Push Buttons ( With Lockable Off ) H ) . Pole A / M Selector Switch For Bms Application I ) .Suitable Rated Cast Resin CtS For Metering On Each Phase, Of Class-1 Accuracy And Of Suitable Burden & Ratioj ) .Digital Ammeter With Inbuilt Selector Switch K ) On / Off-Trip / A / M Potential Free Contacts For Bms L ) .Control Wiring Terminals For Auto Operation Through Potential Free Contacts Ofwater Tank Level Controllers. D ) .Star-Delta Starter Comprising The Following ( For 12.5 Hp To 25 Hp Motors ) For Raw Water Pumps / Treated Water Transfer Pump / Flushing Water Transfer Pump / Borewell / Soft Water Transfer Pump / For Pump Room Fresh Air Fan / For Pump Room Exhaust Air Fan:A ) .12.5 Hp. ( 3 Nos. ) ( Tubewells Pump ) B ) .Type-2 Co-Ordinationc ) .1 No. Suitable Rated Tp Mpcb, -----Ka, Without Inbuilt O / L Relay ( Only Magnetic ) D ) .Suitable Sized 3P Contactors ( Star, Delta & Run Contactors ) With 2 No & 2 Nc Auxiliary Contactse ) Suitable O / L Relay With Inbuilt Spp F ) .On / Off / Trip Indication Lamps ( 110V ) ( Led Type ) G ) .2 Pole A / M Selector Switch For Bms Application H ) .Suitable Rated Cast Resin CtS For Metering On Each Phase, Of Class-1 Accuracy And Of Suitable Burden & Ratioi ) Digital H Inbuilt Selector Switch J ) On / Off-Trip / A / M Potential Free Contacts For Bms K ) Control Wiring Terminals For Auto Operation Through Potential Free Contacts Ofwater Tank Level Controllers. Feeders ( Without Starters ) For Hydronumatic Pump Panels :1 No. Suitable Rated 15 Ka, Tp, Mpcb Without Inbuilt O / L Relay & With 1 No + 1 Nc Auxiliary Contacts & On Indication Lamp 110V ( Led Type ) For 10 Hp Sump Pump Panel. Suitable Rated Cast Resin CtS For Metering On Each Phase, Of Class-1 Accuracy And Of Suitable Burden & Ratio. Digital Ammeter With Inbuilt Selector Switch. Feeders ( Without Starters ) For Sump Pump Panels : 2 No. Suitable Rated 15 Ka, Tp, Mpcb Without Inbuilt O / L Relay & With 1 No + 1 Nc Auxiliary Contacts & On Indication Lamp 110V ( Led Type ) For 15 Hp Sewarage Sump Pump Panel. Suitable Rated Cast Resin CtS For Metering On Each Phase, Of Class-1 Accuracy And Of Suitable Burden & Ratio. Digital Ammeter With Inbuilt Selector Switch. Feeders ( Without Starters ) For R.O Water Booster Pump Panels : 1 No. Suitable Rated 10 Ka, Tp, Mpcb Without Inbuilt O / L Relay & With 1 No + 1 Nc Auxiliary Contacts & On Indication Lamp 110V ( Led Type ) For 3 Hp R.O Waterbooster Pump Panel. Suitable Rated Cast Resin CtS For Metering On Each Phase, Of Class-1 Accuracy And Of Suitable Burden & Ratio. Digital Ammeter With Inbuilt Selector Switch.Spare Starter Feeders ( Without Starters ) With Same Components As Described In Above Written Similar Starter Feeders:5 Hp Motors, Dol Starter ( 2 Nos. ) ( Spare Feeders ) Spare Motor Feeders ( Without Starters ) With Same Components As Described In Above Written Similar Feeders: 2 No. Suitable Rated 15 Ka, Tp, Mpcb Without Inbuilt O / L Relay & 1 No + 1 Nc Auxiliary Contacts & On Indication Lamp ( 110V ) Led Type For 10 Hp Feeder. Suitable Rated Cast Resin CtS For Metering On Each Phase, Of Class-1 Accuracy And Of Suitable Burden & Ratio. Digital Ammeter With Inbuilt Selector Switch. 1 No. Suitable Rated 10 Ka, Tp, Mpcb Without Inbuilt O / L Relay & 1 No + 1 Nc Auxiliary Contacts & On Indication Lamp ( 110V ) Led Type For 5 Hp Feeder. Suitable Rated Cast Resin CtS For Metering On Each Phase, Of Class-1 Accuracy And Of Suitable Burden & Ratio. Digital Ammeter With Inbuilt Selector Switch.Vendor Can Also Consider Integrated Total Co-Ordinated Starter Upto 15Hp.Plumbing Panel As Described Above. 87 Sump Pump Panel ( Upto 5.0Hp Motor ) : A ) .It Shall Control Two Pumps P-1 And P-2. The Operation Sequence Will Be As Under :B ) .P-1 & P-2 To Stop At L-1 C ) .P-1 To Start At L-2 D ) .P-2 To Start At L-3 ( At L-3 Both Pump Will Be Running ) Audible Alarm At L-4 ( 50 Mtr Range ) .E ) .Hooter For Annunciation ( Solid State Buzzer ) F ) .Where L-1 < L-2 < L-3 < L-4 ( Level Of Water In The Sump ) ( Probes / Sensors To Control Operation ) G ) .There Shall Be Selector Switch To Interchange The Starting Sequence Between P1 & P2. ( Selection Mode ) Important Features : Sump Pump Panel Shall Have Following Essential Features: R, Y, B Phase Indicating Lamps With Backup. Auto / Manual Selector Switch. Starter On / Off & High Level Indications, Digital Ammeters For Both Pumps. Mpcb With Inbuilt O / L & Spp, Dol Starter And Dry Run Protection Suitable For Motors And As Per Details Given Below : Incomer:1 No. Suitable Rated 35 Ka, Tp, Mpcb Without Inbuilt O / L & With 1No + 1Nc Auxiliary Contacts For Total 10 Hp Of Sump Pumps ( Both Pumps Working Simultaneously ) .Incomer Metering & PtS :415V / V3 / 110V / V3ptS, Cast Resin Type, 3 Phase For Metering & Indications, Suitable Rated 6A, Tp Mpcb Of The Fault Withstand Capacity As Of The Panel On The Primary Side Of Pt & Suitable Rated 6A, Tp Mcb On The Secondary Side Of Pt. 3 Nos. Cast Resin CtS Of Adequate Class, Burden & Ratio At The Incomer Metering.R, Y, B ( 110V Ac ) Led Lamp & On / Off Indications ( 110V Ac ) Led Type.Digital Vaf Meter At The Incomer ( 110V ) . Control Transformer & Control Circuiting For Starters / Contactors & Indication Lamps : A ) .1 No. 415V / 55-0-55Vcast Resin Dry Type Control Transformer Of Adequate Va Burden To Take Care Of Load Of All The Contactor Coils. B ) .Suitable Rated 6A, Dp, Mpcb Of The Fault Withstand Capacity As Of The Panel For Control Circuiting For Contactors Coils On The Primary Side Of Control Transformer & Suitable Rated 6A, Dp Mcb On The Secondary Side Of Control Transformer. ( Transformer With Primary Taps At ± 2.5%, ± 5%, 50 Hz, Centre Tap Earthed ) . C ) .110V Control Circuitingd ) .110V Control Supply Healthy Indication ( Led Type ) .E ) .Pt Of Adequate Burden Can Also Be Used For Powering Contactor Coils Of Starters And In That Case Control Transformer Can Be Eliminated. Bus Bars : 100A, Tp, Aluminium Bus Bars Of Required Capacity & Ka Rating With Heat Shrinkable Sleeves.Outgoings:Sump Pump Panel ( Upto 5.0Hp Motors ) : 2 Sets Suitable Rated 15 Ka, Tp, MpcbS With Inbuilt O / L Relay & Inbuilt Spp Features ( Site Adjustable ) & With 1No + 1Nc Auxiliary Contacts For 5Hp Each Sump Pump Motor & Each Set With The Following:A ) .Suitable Sized 3P Contactor With 2No + 2Nc Auxiliary Contacts B ) .On / Off / Trip Led Indications ( 110V ) C ) .On / Off Push Buttons D ) .2 Pole A / M Selector Switch For Bms Application E ) .Suitable Rated Single Cast Resin Ct For Metering On Y Phase, Class-1 Accuracy & Of Suitable Burden & Ratio. F ) . Digital Ammeter G ) .On / Off / Trip / A / M Potential Free Contacts For Bmsh ) .3 Nos. Suitable Water Level Controllers With Three Electrodes ( 110Ac ) The Sump Pump Control Panel Shall Be Complete With All Interconnections, Water Level Controllers & Sensors / Probes, Risers, Internal Wiring, Labels, Terminal Block Etc Complete As Required. 88 Sump Pump Panel ( For 7.5Hp To 10.0Hp Motor ) : A ) .It Shall Control Two Pumps P-1 And P-2. The Operation Sequence Will Be As Under :B ) .P-1 & P-2 To Stop At L-1 C ) .P-1 To Start At L-2 D ) .P-2 To Start At L-3 ( At L-3 Both Pump Will Be Running ) Audible Alarm At L-4 ( 50 Mtr Range ) .E ) .Hooter For Annunciation ( Solid State Buzzer ) F ) .Where L-1 < L-2 < L-3 < L-4 ( Level Of Water In The Sump ) ( Probes / Sensors To Control Operation ) G ) .There Shall Be Selector Switch To Interchange The Starting Sequence Between P1 & P2. ( Selection Mode ) Important Features : Sump Pump Panel Shall Have Following Essential Features: R, Y, B Phase Indicating Lamps With Backup. Auto / Manual Selector Switch. Starter On / Off & High Level Indications, Digital Ammeters For Both Pumps. Mpcb With Inbuilt O / L & Spp, Dol Starter And Dry Run Protection Suitable For Motors And As Per Details Given Below : Incomer:1 No. Suitable Rated 35 Ka, Tp, Mpcb Without Inbuilt O / L & With 1No + 1Nc Auxiliary Contacts For Total 10 Hp Of Sump Pumps ( Both Pumps Working Simultaneously ) .Incomer Metering & PtS :A ) .415V / V3 / 110V / V3ptS, Cast Resin Type, 3 Phase For Metering & Indications, Suitable Rated 6A, Tp Mpcb Of The Fault Withstand Capacity As Of The Panel On The Primary Side Of Pt & Suitable Rated 6A, Tp Mcb On The Secondary Side Of Pt. B ) .3 Nos. Cast Resin CtS Of Adequate Class, Burden & Ratio At The Incomer Metering.C ) .R, Y, B ( 110V Ac ) Led Lamp & On / Off Indications ( 110V Ac ) Led Type.D ) .Digital Vaf Meter At The Incomer ( 110V ) . Control Transformer & Control Circuiting For Starters / Contactors & Indication Lamps : A ) .1 No. 415V / 55-0-55Vcast Resin Dry Type Control Transformer Of Adequate Va Burden To Take Care Of Load Of All The Contactor Coils. B ) .Suitable Rated 6A, Dp, Mpcb Of The Fault Withstand Capacity As Of The Panel For Control Circuiting For Contactors Coils On The Primary Side Of Control Transformer & Suitable Rated 6A, Dp Mcb On The Secondary Side Of Control Transformer. ( Transformer With Primary Taps At ± 2.5%, ± 5%, 50 Hz, Centre Tap Earthed ) . C ) .110V Control Circuitingd ) .110V Control Supply Healthy Indication ( Led Type ) .Pt Of Adequate Burden Can Also Be Used For Powering Contactor Coils Of Starters And In That Case Control Transformer Can Be Eliminated. Bus Bars : 100A, Tp, Aluminium Bus Bars Of Required Capacity & Ka Rating With Heat Shrinkable Sleeves.Outgoings:Sump Pump Panel ( For7.5Hp To 10.0Hp Motor ) : 2 Sets Suitable Rated 15 Ka, Tp, MpcbS With Inbuilt O / L Relay & Inbuilt Spp Features ( Site Adjustable ) & With 1No + 1Nc Auxiliary Contacts For 5Hp Each Sump Pump Motor & Each Set With The Following:A ) .Suitable Sized 3P Contactor With 2No + 2Nc Auxiliary Contacts B ) .On / Off / Trip Led Indications ( 110V ) C ) .On / Off Push Buttons D ) .2 Pole A / M Selector Switch For Bms Application E ) .Suitable Rated Single Cast Resin Ct For Metering Oneach Phase Of Class-1 Accuracy & Of Suitable Burden & Ratio. F ) . Digital Ammeter G ) .On / Off / Trip / A / M Potential Free Contacts For Bmsh ) .3 Nos. Suitable Water Level Controllers With Three Electrodes ( 110Ac ) The Sump Pump Control Panel Shall Be Complete With All Interconnections, Water Level Controllers & Sensors / Probes, Risers, Internal Wiring, Labels, Terminal Block Etc Complete As Required. 89 Sewage Treatment Plant:Sewage Treatment Plant Based On Mbbr ( Moving Bed Bio Reactor ) Technology :Supply, Installation, Testing And Commissioning Of Package Type Pre-Fabricated Sewage Treatment Plant Based On Mbbr Technology ( Moving Bed Aerobic Bio-Reactor ) Of 65 Kld Capacity Including All Ms Structure, Mechanical, Electrical And Instrumentation Works As Per Technical Specification Mentioned In The Document. The Scope Shall Also Include To Provide The Ss Bar Screen In Grit Screen Chambers, Grease Separator, Primary & Secondary Treatment Of Waste Water, Air Blowers, All Necessary Interconnecting Piping & Valves, Pumps, Dmf And Acf Filters, Chlorinator, Ultravoilet Dis-Infection Unit, Mcc For Operation Of All Motors, All Inter Connecting Power And Control Wiring, Level Controllers & Other Controls, Ms Puddle Flange ( Hot Dip Galvanized After Fabrication ) , Inlet, Outlet, Overflow, Vent, Manhole Cover Etc, Completed In All Respect In Ready To Use And Easy To Transport Condition. ( The Entire System Tobe Installed Above Ground ) .A ) .Nature Of Effluent - Domestic Sewage From Toilets / Kitchen.B ) .Flow Rate - 65 Kld C ) .Sewage Incoming Characteristics D ) .Ph - 6.5 - 8.5 E ) .Bod5 - Upto 250 - 400 Mg / L F ) .S. Solid - 250 To 450 Mg / Lg ) .Cod 5 - Upto 600 Mg / L H ) .Oil & Grease - 50 Mg / L I ) .Effluent Discharge Standard After Treatment J ) .Ph - 6.5 - 7.5K ) .Bod5 - Less Than 10 Mg / L L ) .S. Solids - Less Than 10 Mg / L M ) .Cod - Less Than80 Mg / L N ) .Oil & Grease - Less Than 5 Mg / L Sewage Treatment Plant Shall Include The Following Items:A ) .Oil & Grease Chamber B ) . Sewage Equalization Tank C ) .Mbbr Tank ( Moving Bed Bio Reactor ) D ) .Tube Settling Tanke ) .Sludge Holding Tank F ) .Chlorine Contact Tank G ) .Filtration Through Mgf, Acf, Chlorinator & Uv Sterlizerh ) .Air Blowers, Pumps & Equipmenti ) .Filter Pressj ) .Piping, Valves Etc K ) .Electrical Panel & Cablingl ) .All Piping, Valves & Level Indicator / Controller Etc. Within Plant Room. Note: A ) .Contractor Shall Ensure Submission Of Detailed Civil General Arrangement Drawings ( Plan & Section ) , P & I ( Programming & Instrumentation ) Diagram, Schematic Diagram For The Above Mention Component & Additional Component Such As Inserts, Puddle Flanges, Vent Pipes Etc. If So Required For The Complete Working Of The Stp And Got It Approved By The Engineer In Charge. B ) .Only Plateform For Stp Plant Shall Be In The Scope Of The Owners. The Sewerage Treatment Contractor Shall Co-Ordinate, Supervise And Get All The Inserts Installed. All Supply Of Ms / Insert Plates Shall Be In The Scope Of The Sewerage Treatment Contractor.Supply, Installation, Testing & Commissioning Of 2 Nos Mild Steel 5Mm Frp Coatingperforated Corrugated Bar Screen With Vertical Grating Made By 3 Mm Thick Stainless Steel Plate, Spacing Of Plates 20 Mm C / C Both Sides With Suitable Lifting Arrangement ( Size 750 Mm Wide X 600 Mm High Approx ) C ) .Supply, Installation, Testing & Commissioning Of 2 Nos Mild Steel 5Mm Frp Coatingperforated Corrugated Bar Screen With Vertical Grating Made By 3 Mm Thick Stainless Steel Plate, Spacing Of Plates 20 Mm C / C Both Sides With Suitable Lifting Arrangement ( Size 750 Mm Wide X 600 Mm High Approx ) D ) .Supply, Installation, Testing And Commissioning Of The Following Tanks And Chambers In Hdpe / Pvc As Per Approved Drawings And Directions Of Engineer Incharge. The Cost Shall Include All The Required Mswalking Platform, Handrail, Staircase, Manhole Cover Etc. All Above Quoted With Minimum 10Mm M.S Tanks With 5Mm Frp Coating Protectiona ) .Mbbr Tank Of Capacity 25000 Litersb ) .Tube Settler Tank Of M Sc ) .Sludge Holding Tank Of Capacity 5000 Litresd ) .Chlorine Contact Tank Of Capacity 10000 Litrese ) .Treated Water Tank Of Capacity 15000 Litres Quoted With Minimum 10Mm M.S Tanks And All Above Item As Per Design Requirments ( No Extra Payment Shall Be Paid ) 90 Supply, Installation, Testing & Commissioning Of Horizontal Type Pumps, Having Cast Iron Body, C.I. Impeller & Shaft Connected To Tefc Motor For 415 Volts, 3 Phase, 50 Cycles A.C. Power Supply Withmechanical / Gland Seal. Protection Complete In All Respects Including Suction And Delivery Headers With Upvc Pipe Of Required Dia, Isolation Valves, Nrv & Pumps Shall Have Following Duty: A ) .Raw Sewage Transfer Pump ( Pumps To Be Suitable To Handle Solid Handling Capacity Upto 40 Mm Size ) Set Of Two Pumps ( 1 Working + 1 Standby ) Capacity - 2.5 Lps ( Required- 2.5M3 / Hr ) Head - 10-12 Mtr.H.P.-2 Hp Approx. 91 B ) .Submersible Sewage Lifting Pumpset Of Two Pumps ( 1 Working + 1 Standby ) Capacity - 1.5 Lpshead - 10-12 Mtr.H.P.-2 Hp Approx. ( Solid Handling Capacity Upto 40 Mm Size ) 92 Supply, Installation, Testing & Commissioning Of Electromagnetic Type Flow Meter At The Outlet Point Of Raw Sewage Transfer Pump Of 50 Mm Size Suitable For 0 - 15 Klh Flow. 93 Supply, Installation, Testing & Commissioning Of Twin Type Rotary Air Blower With Acoustic Encloser, Driven Through “V” Belt Or Directly Coupled Through Flexible Coupling To A Tefc Motor Of Suitable Hp Suitable For 415 ± 10% Volts, 3 Phase, 50 Cycles A / C Supply. Capable Of Delivering 70 Cum / Hr Of Free Air At 0.5 Kg / Cm2. 94 Supply, Installation, Testing & Commissioning Of Air Piping Shall Comprise Of Pipes Droppers / Laterals With Ms ( Epoxy Coated ) Header Complete With All Fittings Such As Tees, Crosses, Plugs, Sockets, Elbows, Reducers, Supports & Clamps, Puddle Flanges Etc Including Cutting Holes In Wall, Makes Chases In Wall And Making Good The Same. Contractor To Submit Detailed P&I Indicating Their Proposal. 95 Supply, Installation, Testing & Commissioning Of Fine Air Diffusers Capable Of Delivering 10-12 Cum / Hr In Mbbr Tank For Providing Areation. 96 Supply, Installation, Testing & Commissioning Of Coarse Air Diffusers Capable Of Delivering 3-6 Cum / Hr In Equalization Tank And Sludge Holding Tank For Providing Areation. 97 Supply, Installation, Testing And Commissioning Of High Surface Area @ 400 M2 / M3 At Least Ring Type Media To Be Used For Bacterial Growth Installed In Moving Bed Bio Reactor Tanks. 98 Supply, Installation, Testing And Commissioning Of Pvc Tube Deck Settling Media To Be Installed In Tube Settling Tank. The Media To Be Supported On Msep Frame With Baffle Plate & Overflow Launder. 99 Supply, Installation, Testing And Commissioning Of Single Stage Horizontal Centrifugal Self Priming Pump With With C.I Body, Bronze Impeller, Shaft Of Stainless Steel, Shaft Sleeve Of Chrome Steel And Delivery Casing In C.I With Mechanical Seal, Connected To A Tefc Inductionmotor Suitable For 415+ / - 10%Volts, 3Phase50 Cycles A.C. Supply With 150Mm Dia Pressure Gauge With Gunmetal Isolation Cock, Vibration Eliminating Pads Under Foundation, Sequence Running Controller, Dry Running Protection, 80X40 Mm I Section Base Plate Bolted To Cement Concrete Foundations Complete Includingisolation Valves, Nrv & Vibration Eliminators On Both Suction & Delivery Side Of Pumps .Vendor To Submit Performance Curves And Technical Catalogue Of The Proposed Model For Review And Information. A ) .Sludge Feed / Transfer Pump ( Pumps To Be Suitable To Handle Solid Handling Capacity Upto 8-10 Mm Size ) B ) .Set Of Two Pumps ( 1 Working + 1 Standby ) C ) . Capacity- 1.5 Lpsd ) .Head - 10.0 Mtr. E ) .H.P.-1.5 Hp Approx. 100 Supply, Installation, Testing And Commissioning Of Horizontal Centrifugal Pumping Set With Cast Iron Body, Bronze Impeller, Shaft Of Ss And C.I. Base & Head With Mechanical Seal, Connected To A Tefc Inductionmotor Suitable For 415 + / - 10%Volts, 3 Phase 50 Cycles A.C Supply With 150Mm Dia Pressure Gauge With Gunmetal Isolation Cock, Vibration Eliminating Pads Under Foundation, Dry Running Protection, 80X40 Mm I Section Base Plate Bolted To Cement Concrete Foundations Complete Including Isolation Valves, Vibration Eliminators On Both Suction & Delivery Side Of Pumps And Nrv On Delivery Side Of Pumps Vendor To Submit Performance Curves And Technical Catalogue Of The Proposed Model For Review And Information.A ) .Filter Feed Pumpsb.Set Of Two Pumps ( 1 Working + 1 Standby ) C ) .Capacity- 3.0 Lps ( Suggested And Quoted For 5000Lph ) D ) .Head - 30.0 Mtr.E ) .H.P.-3.0 Hp Approx. 101 Supply, Installation, Testing & Commissioning Of Vertical Self Supporting Filtration Unit Fabricated From Ms Sheet As Per Is: 2825 ( Minimum Thickness Of Shell 8 Mm And Dished Ends 10 Mm ) Pressure Gauges, Sample Cock, Gi Class C Face Piping, Ci Butterfly Valves And All Accessories, With Initial Charge Of Filter Media Including Anthracite, Painting Inside With Epoxy Paint And Outside With Two Coat Of Red Oxide Primer And Two Or More Coat Of Synthetic Enamel Paint, Testingand Commissioning Complete.A ) .Mulitgrade Pressure Sand Filtercapacity - 5000 Lph Filtration Rate -14000Lph / Sqm Filter Dia Approx. - 800 Mm Working Pressure: 3.0 Kg / Sqcm. Test Pressure : 4. 5 Kg / Sq Cm 102 B ) .Activated Carbon Filter Filtration Rate -14000Lph / Sqm Filter Dia Approx. - 800 Mm Working Pressure: 3.0 Kg / Sqcm.Test Pressure : 4. 5 Kg / Sq Cm 103 Supply, Installation, Testing & Commissioning Of Metering Pump Type Chemical Doser With 100 Lits. Pvc / Hdpe Solution Tank, Injection Fitting Assembly, Suction And Delivery Hose Upto The Point Of Injection, Capacity 0-6 Lph, Complete In All Respects. 104 Supply, Installation, Testing & Commissioning Of Ultravoilet Dis-Infection Unit. The Unit Shall Have Over 99.9 % Bacterial Reduction From Inlet To Outlet. The Dis-Infection Chamber Shall Be Constructed Of Ss 316L On All Welted Parts. The Uv Lamp Shall Be Of Low Pressure Mercury Vapour Type With Hard Glass Enclosure, The Sockets Shall Be Water Tight & Vibration Resistant. The Lamp Life Shall Be Rated For 6000 Hours. The Unit Shall Be Complete With Temperature Safety Control, Lamp Out Alert Circuit & Uv Radiometer With 4 – 20 Ma Output. The Uv Unit Shall Have With Reactor, Cabinet Housing, Cabinet Cooling, Treatment Chamber, Electrical Panel, Temperature Safety Control, Lampout Alert, Uv Radiometer Along With Uv Monitoring System And Uv Monitoring Readout Panel.The Uv Dosage Should Be > 60, 000 Uw – Sec / Sq.Cm. The Lamps Should Be Selected Based Upon The Flow Requirement Of Respective Unit.Flow Rate : 5 Cum / Hr 105 Supply, Installation, Testing & Commissioning Of All Pipings ( As Described Below ) And Isolation Control Valves Including All Necessary Fittings And Clamps, Supports, Hangers As Required I / C Cutting And Making Good The Walls Wherever Required Complete In All Respects For Making The System Complete.A ) .Gi : Submerged Air Piping ( We Suggest Upvc. Gi Is Never Used For Submerged Piping ) Ms Epoxy: Air Piping & Pumped Effluent Riser ( Non-Submerged ) Upvc : Interconnecting Pipe Line After Delivery Header Of Pump / Filtercontrollers With Low Voltage Relays, Stainless Steel Probes And Pvc Shroud, Control Cabling As Required Length. ( No Of Probes As Required For Function Of Each Controller ) . 106 B ) .Filter Feed Pumps To Cut Off Duty Pump On Low Water Level In The Chlorine Contact Tank And High Water Level In The Treated Water Tank And To Start Pump At Low Water Level In The Treated Water Tank. 107 Supply, Installation, Testing & Commissioning Of Filter Press Of Plate Size 18X 18X 12 Nos. Plate With Screw Feed Pumps Of 5 M3 / Hr @ 40 M Head Capacity ( 1 Working + 1 Standby ) Complete In All Respects. 108 Providing Installing Testing And Commissioning Of Ultra Filteration ( Uf ) System For Further Polishing Treated Effluent And Capable Of Producing 5, 000 Litre / Hour. The System Shall Be Complete With Uf Feed Pumps ( 1W+1S ) , Backwash Pumps ( 1W+1S ) , Cartridge Filters ( Fabricated| ) , Uf Membranes Flushing / Cleaning System Complete Instrumentation For Automation And Monitoring Rotameters Pressure Gauges Interconnecting Pipeword Electrical Cabling And Switchgear, All Complete Electrical Installation For Stp 109 Design, Fabrication, Assembling, Wiring, Supply, Installation, Testing And Commissioning Of Motor Control Centre Fabricated Out Of 14 Gauge Crca Sheet Steel. Cable Gland Plates Shall Be Provided On Top As Well As At The Bottom Of The Panels. Panels Shall Be Treated With All Anticorrosive Process Before Painting As Per Specifications With 2 Coats Of Red Oxide Primer And Final Approved Shade Of Powder Coated Paint. 2 Nos. Earthing Terminals Shall Be Provided For 3 Phase, 4 Wire, 50 Hz Supply System. Lifting Hooks Shall Also Be Provided In Case Of Large Panels. Approval Shall Be Taken For Each Panel Before Fabrication. Quoted Rates Shall Be Inclusive Of Cables ( In Accordance To Specification ) With Earthing From Panel To Each Motor / Equipment.Motor Control Centreincoming: A ) .200 Amps Tpn Mccb With The Following Accessories:B ) .0-500 Volts 96 X 96 Mm Square Electronic Voltmeter With Selector Switch Shall Be Protected By 2 Amps Tp Mcb. 1 Set.C ) .0-100 Volts 96 X 96 Mm Square Electronic Voltmeter With Selector Switch And Shall Be 100. / 5 Amps 10 Va Cl: Cts. 1 Set. D ) .Pharse Indicating Lamps Shall Be Protected By 2 Amp Sp Mcb 3 Sets. Bus Bar:A ) .200 Amps Tpn ( 15 Ka ) Copper Bus Bar With Heat Shrinkable Insulation Sleeves.Outgoing; A ) .10 Nos. Of 25 Amp Capacity Tpn Mcb With 10 Nos. Dol Starters And Out Going Feeders To All The Pumps Etc. ( Including Standbies ) . Each Compartment Shall Contain Auto / Manual Selector Switch Andindicating Lamp With Mcb’S For ‘On / Off / Trip’ Status Of Motor B ) .Spare 25 Amps TpnmcbS2 Nos. C ) .Spare 32 Amps TpnmcbS2 Nos. D ) .Necessary Cable Alleys, Internal / Cabling, Wiring, Cabling From Mcc To Various Pumps / Equipment And Interlocking, Earthing For All Equipment Shall Also Included Mcc For All Stp Equipments / Pumps As Described Above.Notes : A ) .All Mccbs / Mcbs Shall Be Of 15 Ka Breaking Capacity And Suitable For Motor Duty Application.B ) .All Motor Starters Shall Be Provided With Automatic Level Controller. C ) .Dol Starters Shall Be Used For Motors Below 10Hp And Star-Delta Starters For Other Motors . Motor Control Centre Incoming 200 Amps Tpn Mccb With The Following Accessories:0-500 Volts 96 X 96 Mm Square Electronic Voltmeter With Selector Switch Shall Be Protected By 2 Amps Tp Mcb. 1 Set.0-100 Volts 96 X 96 Mm Square Electronic Voltmeter With Selector Switch And Shall Be 100. / 5 Amps 10 Va Cl: Cts. 1 Set.Phase Indicating Lamps Shall Be Protected By 2 Amp Sp Mcb 3 Sets.Bus Bar 200 Amps Tpn ( 15 Ka ) Copper Bus Bar With Heat Shrinkable Insulation Sleeves.Outgoing10 Nos. Of 25 Amp Capacity Tpn Mcb With 10 Nos. Dol Starters And Out Going Feeders To All The Pumps Etc. ( Including Standbies ) . Each Compartment Shall Contain Auto / Manual Selector Switch Andindicating Lamp With Mcb’S For‘On / Off / Trip’ Status Of Motorspare 25 Amps TpnmcbS2 Nos. Spare 32 Amps TpnmcbS2 Nos. Necessary Cable Alleys, Internal / Cabling, Wiring, Cabling From Mcc To Various Pumps / Equipment And Interlocking, Earthing For All Equipment Shall Also Included Notes : All Mccbs / Mcbs Shall Be Of 15 Ka Breaking Capacity And Suitable For Motor Duty Application.All Motor Starters Shall Be Provided With Automatic Level Controller.Dol Starters Shall Be Used For Motors Below 10Hp And Star-Delta Starters For Other Motors .Provision Shall Be Made For Providing Potential Free Contacts To All Pumps Starters.Mcc For All Stp Equipments / Pumps As Described Above. Sub Total Of Part A 110 Part B ( O & M Cost ) ( For 5 Years ( 60 Months ) From Final Handing Over Of All Works. ) ( Optional ) Trained Operator To Operate The Stp Round The Clockincluding Operator And Regular Visit Of Supervisor. Perannum Including All Charges Like Amc , Monthly Charges Of Water Analysis And All Consumables Etc Included. Sub Total Of Part B ( Rate Only ) 111 Part:C Providing & Laying Upvc Pressure Pipes Of 6 Kg / Sq.Cm Pressure Rating Class 3 ( Is : 4985-2000 ) Including Fittings, Tees, Bends, Clamps, Coupling And Adaptors Supports, And Jointing With Solvent Joint, Testing And Necessary Earth Work In Excavation, Backfilling, Disposal Of Surplus Earth With A Lead Up To 100M Complete, Compaction And Consolidation Including Sand Bedding All Around Upvc Pipe & Fittings And Thrust Blocks At Bends As Per Standard Design.200Od 112 Constructing Rccchamber Of Holding Capacity 10 M3 With Grade Of M25 Including Cost Of Centering , Shuttering & Pcc Below Foundation In 1: 5:10 & 75 Mm Thick And Inside Chamber Of 75Mm Thick As Per Standard Design Including Inside Plastering With Cement Mortar 1:6 ( 1 Cement :6 Coarse Sand ) 12 Mm Thick Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design .Rate To Include Cost Of Reinforcement , Excavation And Filling Of Earth. Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) , Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. The Contractor Has To Detect Different Unilities Like Sewer Line , Water Supply Line , Electrical Cable , Telephone Cable , Gas Pipe Line Etc. Using Utility Detecting Machine Before Start Of Excavation And Shall Start Excavation Only After Getting Permission Of Engineer In Charge.All Kinds Of Soil.Depth Upto 1.5M From Existing Ground Level 113 B ) Filling Available Excavated Earth ( Excluding Rock ) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Upto 1.5 M. 114 Providing & Laying Cement Concrete - All Works Upto Plinth Level : C ) 1:4:8 ( 1 Cement : 4 Coarse Sand ( Zone-Iii ) : 8 Graded Stone Aggregate 40 Mm Nominal Size ) 115 Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, Including Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-In-Charge. ( Note :- Cement Content Considered In This Item Is @ 330 Kg / Cum. Excess / Less Cement Used As Per Design Mix Is Payable / Recoverable Separately ) . A ) Uptoplinth 116 Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level.B ) Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More 117 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For : C ) Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete 118 D ) Suspended Floors, Roofs, Landings, Balconies And Access Platform 119 Brick Work With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 10 In Foundation And Plinth In: A ) Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) For 230Mm Thick Brick Work 120 B ) 12 Mm Cement Plaster Of Mix :1:4 ( 1 Cement: 4 Fine Sand ) 121 C ) 15 Mm Cement Plaster On Rough Side Of Single Orbrick Wall Of Mix:1:4 ( 1 Cement: 4 Fine Sand ) 122 D ) 6 Mm Cement Plaster Of Mix :1:3 ( 1 Cement : 3 Fine Sand ) 123 Designing, Preparation Of Shop Drawings, Supplying, Erection, Testing, Commissioning Of All Mechanical, Electrical And Other Components Including Getting Approval Of Successful Test Results From Approved / Authorized Agency From Pollution & Environmental Authorities, Operating & Maintaining Upto Successful Commissioning, For 5 M3 / Day Capacity Sewage Treatment Plant Sewage Treatment Plant Near Workshop Area ( Complete System To Be Compact Type, Skid-Mounted / Cabinet Enclosed, As Per Detailed Shop Drawings To Be Approved ) Suprime / Sintex Maketotal C / F To Summary 124 R.O Water Treatmentplant: Supply, Installation, Testing And Commissioning Of R.O. Plant Capacity Of 750 Lph ( Complete System To Be Compact Type, Skid-Mounted / Cabinet Enclosed, As Per Detailed Shop Drawings To Be Approved ) For The Following Parameters And Consisting Of ( But Not Limited To ) The Following Main Components:- ( I ) Inlet Quantity : As Per Detailing ( Ii ) Output Quantity : 750 Lph ( Iii ) Inlet Tds : 600 Ppm ( Iv ) Outlet Tds : 75 Ppm ( V ) Inlet Hardness : 350 Ppm ) ( Vi ) Outlet Hardness : 50 Ppm ) Raw Water Pumps Of Horizontal, Centrifugal Type Suitable For A Flow Rate Of 1500 Lph At 25M Head. The Pump Construction Shall Be Of Ss-304 & Impeller Shall Be Also Ss-304. The Motor Shall Be Tefc Suitable For A Supply Of 415V / 3-Phase / 50Hz Supply. The Pump Shall Be Supplied Complete With Base Channel Coupling Foundations, Bolts, Pressure Gauge At Inlet And Outlet Of Each Pump. -- 2 Nos. ( 1W+1S ) Special Antiscalant Dosing System Consisting Of One Hdpe Tank Of 100 Litre Capacity With A Positive Displacement Diaphragm Dosing Pump Having Variable Flowrate Of 0-6 Lph. The Motor Shall Be Suitable For Operation At 240V / Single Phase / 50Hz Supply. The Pump Shall Be Supplied Complete With Necessary Polypropylene Piping, Valves, Strainers & Injection Fittings. -- 1 Set Micron Cartridge Filter Suitable For A Flowrate Of 1500 Lph To Achieve Particle Filtration Of Less Than 5 Microns. The Unit Shall Be Supplied Complete With Inlet And Outlet Branches Removal Cap For Replacement Of Element, Inlet And Outlet Pressure Indicators. ( One For The Pressure Treatment & Other For Cip System ) Moc: Polypropylene -- 2 Sets R.O High Pressure Feed Pumps Of Vertical, Multistage Centrifugal Type Suitable For A Flowrate Of2000 Lph At 14 Kg / Sq.Cm. The Pump Construction Shall Be Of Ss-316-L & Impeller Shall Be Also Ss-316-L. The Motor Shall Be Of Tefc Suitable For A Supply Of 415V / 3 Phase / 50 Hz Supply. The Pump Shall Be Supplied Complete With Base Channel Coupling Foundation, Bolt, Pressure Gauge At Inlet And Outlet Of Each Pump.- 2 Nos.R.O. Modules Made Out Of Spiral Wound Thin Film Composite Suitable To Withstand Pressure Of 20Kg / Sq.Cm. Suitable Bspt / Npt Connections Shall Be Used For Connecting Feed & Reject Ends. The Modules Shall Be Supplied Complete With All Necessary Instrumentation, Valves For Sampling, Drain, Reject & Permeate, Epoxy-Coated Structural Steel Bases And Supports, As Per Following System Capacity Requirements: ( I ) Total Net Treated Water Output Of System = 750 Lph ( Ii ) System Recovery= 50 - 60 % ( Iii ) Filtration Area Per Membrane = 85 Sq.Ft. ( Iv ) Number Of Membranes = The Total Number Of Membranes Required Shall Beas Per Requirements, Supported By Calculations From The Vendor. Centralised Plc Control Panelalong With Touch-Screen Digitial Display Board Along With All Digital Sensors For Tds & Flow, Made Out Of Crca Sheet Min. 2Mm Thick Having Main Contactors For All Pumps ( Listed Above ) Including Spp, 3 Phase Thermal Overload Relay. The Control Panel For Monitoring And Control Of P.O. System Shall Include All Required Signal Lamps, Hrc Fuses, Annunciation Box With Hooter. All Control And Power Cabling Along With Double Earthing Between The Panel Shall Be Included In The Scope Of Supply Of The Contractor. An Emergency Stop Push Button Shall Be Provided In The Panel. The Mcc Panel Shall Have The Following Interlocks:- I ) High Pressure Pump Unit Trip In Case Of Low Suction Pressure. Ii ) High Pressure Pump Unit Trip In Case Of High Discharge Pressure.Iii ) Special Anti-Scalant Dosing Pump Trips In Case High Pressure Pump Trips And Vice Versa.Iv ) High Pressure Pump Trip In Case Of High Conductivity In Permeate.V ) Shc Dosing Pump Trips Incase High Pressure Pump Trips And Vice Versa. Vi ) Orp With Dump Valve.-- 1 Seti ) First Fill Of All Chemicals And Lubricants To Commission And Operate The Plants. --1Lotj ) All Interconnecting Piping Work With Valves:- I ) Low Pressure Side Till R.O. Feed Water Pump. Piping Shall Be Of Extra Strong Pvc And All Valves Shall Be Of Extra Strong Pvc And All Valves Shall Be Pvc Ball Valves. -- 1 Lotii ) High Pressure Side Piping From The R.O. High Pressure Pumps To The Reject Stream Control Valves Shall Be Of Ss - 304 Using All Ss Fittings Ball Valves Of Suitable Pressure Rating Shall Be Used Till 25 Mm Size, Above 25 Mm, Flanged Globe / Wafer Butterfly Valves In Ss Construction Shall Be Used. Rejects Pressure Control Valves Shall Be Globe Valve And Feed Flow Control Valve Shall Be Of Ss-304. -- Lotiii ) Before Procurement Of Material Contractor Should Be Get Technical Approval From Consultants. ( All For Above From A To J Complete ) 125 R.O Water Storage Complete 316 Stainless Steel Treated Water Storage Tank ( Double Wall ) Of Capacity 2000 Litres Including All Inlet / Outlet Connections, Accessories, Valves, Double Seal Manhole Covers, Insulation Etc.The Stainless Steel Tank Must Be Ozone Resistant And To Be Used As Ozone Contact Tank. Fabrication To Be Done As Per Approved Shop Drawing. ( Make :Nector ) 126 Providing And Placing On Terrace ( At All Floor Levels ) Polyethylene Water Storage Tank, Is : 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflowpipes But Without Fittings And The Base Support For Tank.. 127 Activated Carbon Filter ( Automatic Type For Online Installation Before The Micron Filters ) Suitable For A Flow Rate Of 1500 Lph. The Material Of Construction Shall Be Composite Frp. The Unit Shall Be Supplied Complete With Multi-Port Valves, Inlet And Outlet Branches Removal Caps Of Replacement Of Elements Inlet And Outlet Pressure Indicators. -- 1 Set 128 Hydropneumatic System For R.O Supply Providing Fixing And Commissioning Suitable Complete Composite Hydropneumatic System Consisting Ofhorizontal / Vertical Multistage Centrifugal Pump Having Stainless Steel Impellers, Stainlesssteel Shaft, Stainless Housing And Single Mechanical Seal And Pressurised Tankof Required Specifications And Of Non-Toxic Rubber Diaphragm, Complete With All Accessories Including Pressure Switch, Pressure Gauge And Electrical Panel With All Necessary Protection And Operational Devices I.E Alternate Pumping Operation And Shut Off During Dry Running Conditions Etc., And Inclusive Of Ss 316 Suction And Delivery Manifold Of Required Size With Non-Return Valve And Ball Valveand Withsuitableelectrical Motor To Be Operated On 210 / 220 Or 400 / 440 Volt 50 Cycle Suitable For Following Duty And With Total No. Of Pumps - 2 Nos. ( 1 Working+ 1 Standby ) Complete With The Approval Of Engineer-In-Charge.- Before Procurement Of Material Contractor Should Be Get Technical Approval From Consultants.A ) Discharge:150 Lpmb ) Head:45 M C ) App. Capacity Of Thevessel ( Frp ) : As Requiredtotal C / O To Summary 129 Hot Waterboilers And Other Related Accessories Electrical Hot Water Generators System With Solar Back Up.Hot Water Mixing Storage Tank ( 2 Sets For Club And Benquet Hall ) Supply, Installation, Testing And Commissioningof Solarwater Heating System Capable Of Generating 7500Lpd Of Hot Water Per Day At 60 Oc Along Withinsulated Horizontalhot Watermixing Tank Capacityand Design Code I.S: 2825 Fabricatedof 6 Mm Thick S.S. 304Plateand 10 Mmthickdishedend And Nozzles Complete With Inlet, Cold Waterinlet / Outlet Chain Connection Withflanges, Manhole With Bolted Cover With 72 Kw Electrical Back Up Along With Control Panels . Tankshall Beinsulated With 50 Mm Thickresin Bondedfibre Glass ( Density 24 Kg / Cum ) And Covered With500gpolythene Sheetand 24 Gauge Aluminumsheet Cladding Giving Proper Overlaps And Sealing The Joints With Suitable Adhesive Compound, Including The Following Additional Accessories / Specifications:Working Pressure : 7.5 Kg / Cm²i ) Safety Valveii ) Dial Type Thermometer Iii ) Thermowell For Thermostat Elements Cold Water Inlet Valve 80 Mm Dia Check Valve In Cold Water Inlet 80 Mm Dia.Hot Water Inlet / Outletsecondary Side 50 Mm Dia Valve Plate Type Heat Exchanger Compleate With Pumps Required Specification.Hot Water Outlet Connection Valve To System 100Mm Diaplate Type Heat Exchanger Compleate With Pumps Required Specification.Hot Water Outlet Connection Valve To System 100Mm Dia Hot Water Return Inlet 65 Mm Dia Drain Valve 50 Mm Diaair Release Valve 25Mm Diahot Water Return Nrv 65 Mm Dia Solar Pre Heating Working Inlet 80 Mm Dia Butterfly Valvesolar Pre Heating Working Inlet 80 Mm Dia Nrv Electrical Control Panel As Per Approved Apecification Temp. Controller 130 Hot Water Returnpumps For Domestic Waterprovidingand Fixing Horizontal Multistage Centrifugal Pumping Set With Stainless Steel Ss-304 Stage Casing And Ss-304 Impellers With Stainless Steel Ss-304 Shaft As Per Iec Standards Andss - 304 Suction & Discharge Casing, Connected To Tefc Ventilated Induction Motor Of 2 Pole, 2900 Rpm, Suitable For 400 / 440 V Phase, 50 Hz A.C. Supply With Pressure Gauge And With Gunmetal Isolation Cocks, Vibrationelimination Pads Etc. Complete With Base And Frame, Nuts & Bolts And Necessary Rcc Foundations As Per Requirement As Per Instructions And Pump Shall Follow Following Dutynos : 2 ( 1 W +1 S ) Capacity: App.100 Lpm Head :15 M 131 Solar Hot Water Re-Curculation Pumps : Providingand Fixing Horizontal Multistage Centrifugal Pumping Set With Stainless Steel Ss-304 Stage Casing And Ss-304 Impellers With Stainless Steel Ss-304 Shaft As Per Iec Standards Andss - 304 Suction & Discharge Casing, Connected To Tefc Ventilated Induction Motor Of 2 Pole, 2900 Rpm, Suitable For 400 / 440 V Phase, 50 Hz A.C. Supply With Pressure Gauge And With Gunmetal Isolation Cocks, Vibrationelimination Pads Etc. Complete With Base And Frame, Nuts & Bolts And Necessary Rcc Foundations As Per Requirement As Per Instructions And Pump Shall Follow Following Duty Nos : 2 ( 1 W +1 S ) Capacity: App100 Lpm Head :55 M 132 Electrical Panel Providing Motor Control Centres Fabricated From 16 Gauges M.S. Sheet With Powder Coated Finish. The Control Panels Should Be Comparable With H.P. Of The Motor As Specified.For Hot Water , Steam Genration Systemshot Water Recuculation Pumps, Hot Water Supply Pumps Condensate Pumps Etc.A ) One Incoming Main Isolation Mccb Of Required Rating.B ) Fully Taped Aluminum Bus Bar Ofrequiredcapacity In A Separate Bus Bar Chamber.C ) Isolation Switch Units With Mccbof Required Rating, For Each Unit.D ) Fully Automatic Dol Starter With Pushbutton And On / Off Indicating Lights For Each Unit, For Following Requirements:I ) Hot Water Boilers 2 Nos. Of Required 74 Kw Eachii ) Hot Water Re-Circulation Pumps 2 Nos. ( 1 Working+ 1 Stand By ) Of Required Hp Iii ) Solar Hot Water Recirculation Pumps 2 Nos. ( 1 Working+ 1 Stand By ) Of Required Hpiv ) One No. Spare Feeder Required 5 Hprotary Switches For Auto / Manual On / Off Operations For Each Unit.Rotary Duty Selector Switches.Panel Type Voltmeter 150Mm With Rotary Selector Switch For Reading Voltage Between Phases.Neon Phases Indicating Lights On The Incoming Mains. Single Phasepreventorfor Each Motor. Ct Operated Relayall Internal Wiring Colour Coded From Incoming Mains To Various Switchgear, Starter, Meter, Indicating Lamp And Bus Bar. All The Cable Entry To The Panel Shall Be From The Top. ( All For Above From Item ( A ) To ( L ) Complete Set ) . ( The Shop Drawing To Be Preparedand Approved Before Fabrication ) Total C / O To Summary 133 Swimming Pool Filteration System Recirculation Pumps Main Pool + Jacuzziarea : 550 M2 X 1.2 M Balancing Tank : 60 M3total Pool Volume : 660 M3 + 60 M3 = 720 M3filtration Flow Rate : 180M3 / Hr Filtration Plant With Pumpsupply, Instalation, Testing & Commissioning Of Bobbin Wound Side Mount Sand Filter Manufactured With Fiber Glass And Polyester Resin, Uv Resistance Surface, Fitted With Collector Arms And Diffuser Made From Unplasticised Pvc And Polypropylenewith Lid In Polyester Resin And Fibre Glass, Manual Air Purgeand 4 Pvc Flanged Connection For Inlet And Outlet, Pressure Gauge, Water Drain / Empty Drain For Filter Etc.Complete In All Respects. Including Corse & Fine Silica Sand Media For Filterapx. 7200Kgcapacity 60000 Ltrs / Hrdesign @30000 Ltrs / Sqm / Hr.Diameter1600 Mm Working Pressure4.0 Kg / Cm² 134 Valve Battery Valve Battery Manifold Made In Pvc With Flanges For Connecting To Filters Consists Of Set Of 5 - Buttterfly Valves For Carrying Out Filtration, Back-Washing, Rinsing And Shut Down Of The Filters. Size : 4 Inchsupply, Instalation, Testing & Commissioning Of Self Primingpumps With Ci Body, In Built Ci Strainer Basket, Impeller In Ci / Bronge, Motor Shaft In Stainless Steel Aisi-420, Mechanical Seal In Sic - Sic / Carbon - Ceramic, Motor Housing In Aluminium, Withmotor -2850Rpm, F Class Insulation, Protection Ip-55. ( 3W+1S ) 135 Supply, Instalation, Testing & Commissioning Of Self Primingpumps With Ci Body, In Built Ci Strainer Basket, Impeller In Ci / Bronge, Motor Shaft In Stainless Steel Aisi-420, Mechanical Seal In Sic - Sic / Carbon - Ceramic, Motor Housing In Aluminium, Withmotor -2850Rpm, F Class Insulation, Protection Ip-55. ( 3W+1S ) Capacity60000 Ltrs / Hrhead 16 Mtrhp 7.5, Three Phase 136 Swimming Pool U.V. Sterlizersupply, Instalation, Testing & Commissioning Of U.V. Sterlizer With S.S. Housing Outside, U.V. Lamp, Glass Tube And All Other Accessories With Cleaning Arrangement, Supports, Inlet Outlet Connection With Bypass Arrangement Including S.S. Cabinet With Glass Door Of Suitable Size To House The U.V. Sterlizer Complete With Required Accessories. Flow Rate = 60000 Ltr / Hrworking Pressure = 4.0 Kg / Sqm Uv Lamp Wattage = 400 W 137 Dosing Pumpsupply, Instalation, Testing & Commissioning Of Chemical Dosing Pumpfor Chlorination With 200 Ltrs. Sintex Tank And Accessories Capacity0-20 Litres / Hr.Head35 M 138 Stainless Steel Drain Supply, Instalation, Testing & Commissioning Ofstainless Steel Drain Grating Plate Made Out Of 316 Quality S S Plates With Suitable Supporting Frame And Of Following Sizes And Having Holes Of Required Size For Drainout Chamber.Size 400X400 Mm 139 Inlet Nozzlesupply, Instalation, Testing & Commissioning Of Flow Adjastable Abs Inlet Nozzles Uv Treated With S.S. Screws To Fit In The 2 Pvc Pipes 140 Suction Inlets ( Vacuum Points ) Supply, Instalation, Testing & Commissioning Of Abs White Plastic Suction Port / Vacuum Nozzle With 2 Inch Solvent Cement Connection 141 Supply, Instalation, Testing & Commissioning Of Stainless Laddersteel 316 Ladders, Width: 500Mm Wide, Handrails Dia 43Mm Stainless Steel, Non-Slip Stepsprovided With Anchoring Socket.A ) 3 Step Standard Ladder With Anti-Skid Steps 142 B ) 4 Step Standard Ladder With Anti-Skid Steps 143 Underwater Led Lights Supply, Instalation, Testing & Commissioning Of 12Volt 54 W Under Water Stainless Steel 316L Led Light Fixture ( Ip 68 ) Including All Required Assessories & Making Connection As Required. With 2 Mtr Power Cord. 144 Power Supply Supply, Instalation, Testing & Commissioning Oftransformer For Led Lights 12V Dc, 30 Amp 145 Deck Box Supply, Instalation, Testing & Commissioning Of Abs White Plastic Deck. 146 Cleaning Accessories A ) Extensivetelescopic Handle, ( 2.4 - 4.8 ) Metres Long &1.1Mm Thick For Cleaning Attachment In Anodized Almunium. 147 B ) Transparent Blue Polyethylene Hose 40Mm ( 1-1 / 2 ) Dia 30 M Length. 148 C ) Surface Net Skimmer Made In Polypropylne 149 D ) Deep Bag Net Skimmer Made In Polypropylne 150 E ) Curved Polybristle Wall Brush 450 Mm 151 F ) Test Kit For Ph And Chlorine. 152 G ) Hi-Grade Stainless Steel Algae Brush - 10 153 H ) Vacuum Head With Ss-Body, 1 1 / 2 Connection Size 900 Mm Long 154 I ) Deluxe Large Vacuum Head With 4 Wheels, Alu-Body, Plastic Handle, 1 1 / 2 Connection Size 445X130 Mm 155 J ) Polybristle Wall Brush 10 ( 26Cm ) 156 K ) Chemical Tcca 90 ( 50 Kg. ) & Alum ( 30 Kg. ) 157 L ) Nylon Rope 158 Upvc Pipesproviding And Fixing Upvc Pressure Pipes ( 10Kg / Cm2 ) With Plain Socket Suitable For Solvent Cement Jointing Conforming To Is:4985 / 2000 & Fittings Conforming To Is 7834 / 87.Cut To Required Lengths Including All Necessary Fittings And Specials Such As Bends, Tees, Unions, Reducers, Flanges And Plugs Etc. The Pipes & Fittings Shall Be Tested To A Pressure Of 10 Kg / Sq.Cm.A ) 32 Mm Dia 159 B ) 50 Mm Dia 160 C ) 63 Mm Dia 161 D ) 75 Mm Dia 162 E ) 90 Mm Dia 163 F ) 110 Mm Dia 164 G ) 160 Mm Dia 165 H ) 200 Mm Dia 166 I ) 250 Mm Dia 167 Ball Valveproviding And Fixing Pvc Lever Operated Ball Valve Of Full Flow With Setting And Gland Of Superior Quality Having Minimum Working Pressure Of 10 Kg / Cm2 With Union, Flanges Where As Required.A ) 32Mm Dia 168 40Mm Dia ( Rate Only ) 169 50Mm Dia ( Rate Only ) 170 63Mm Dia 171 75Mm Dia ( Rate Only ) 172 90Mm Dia ( Rate Only ) 173 Butterfly Valve Providing And Fixing Upvc Butterfly Valves. Tested To A Pressure Not Less Than10 Kg / Sq.Cm. Including Rubber Gasket, Flanges, Nuts, Bolts, Washers Complete As Required. A ) 90 Mm Dia 174 B ) 110 Mm Dia 175 C ) 160 Mm Dia 176 D ) 200 Mm Dia 177 E ) 250 Mm Dia 178 Non Return Valveproviding And Fixing Pvc Ball Type Or Spring Loaded Non Return Valve With Setting And Gland Of Superior Quality Having Minimum Working Pressure Of 10 Kg / Cm2 With Union, Flanges Where As Required.A ) 50Mm Dia 179 B ) 63Mm Dia 180 C ) 75Mm Dia 181 Providing And Fixing Of Upvc Wafer Check Valve Non-Return Valves ( Pn 10 ) Complete With Matching Flanges, Rubber Insertion, Nuts, Bolts And Washer Etc. Of Following Sizes.A ) 75Mm Dia 182 B ) 90 Mm Dia 183 C ) 110 Mm Dia 184 D ) 160 Mm Dia 185 E ) 200 Mm Dia 186 F ) 250 Mm Dia 187 Puddles Sleevesupply & Fixing Of Following Sizes Of Heavy Duty Pvc Puddle Flanges ( Upvc Pipe ( 10 Kg / Cm2 ) Fixed With Flanges, Length 400 To 600 Mm Length ) On The Wall Of Plantroom, Balancing Tank And The Water Body Walls & Slab ( As Required ) . To Be Laid In Between The Steel Reinforcement Before Rcc. Does Not Include Any Civil Work. A ) 32 Mm Dia 188 C ) 50 Mm Dia 189 D ) 63 Mm Dia 190 E ) 75 Mm Dia 191 F ) 90 Mm Dia 192 G ) 110 Mm Dia 193 H ) 160 Mm Dia 194 I ) 200 Mm Dia 195 J ) 250 Mm Dia 196 Supply, Laying, Testing And Commissioning Of Ss 304 Grade 300Mm Dia Pump Suction Header With 2 Nos 200Mm Dia Flange Connection For Balancing Tank To Pump Suction Header, 1 No. 90 Mm Dia Flange Connection For Vacuum Pipe & 1 No. 200 Mm Dia Flange Connection For Pool Drain Pipe & 4No. 200Mm Dia & 2 No. 160Mm Diaflange Connection For Pump Suction. 197 Supply, Laying, Testing And Commissioning Of Ss 304 Grade 200Mm Dia Pump Delivery Header With 1 Nos 200Mm Dia Flange Connection For Filter Inlet Header, 1 No. 160 Mm Dia Flange Connection For Drain Pipe & 4 No. 160Mm Dia Flange Connection For Pump Delivery. 198 Supply, Laying, Testing And Commissioning Of Following Size Pvc Insulated Sheathed Copperconductor 1100 V Grade Unarmoured Cable With Required Size Of Sleeves Complete As Required. A ) 4 X 16 Sq.Mm 199 C ) 4 X 6 Sq.Mm ( Rate Only ) 200 D ) 4 X 4 Sq.Mm ( Rate Only ) 201 E ) 4 X 2.5 Sq.Mm 202 F ) 4 X 1.5 Sq.Mm ( Rate Only ) 203 G ) 3 X 6 Sq.Mm ( Rate Only ) 204 H ) 3 X 4 Sq.Mm 205 I ) 3 X 2.5 Sq.Mm ( Rate Only ) 206 J ) 3 X 1.5 Sq.Mm ( Rate Only ) 207 K ) 2 X 6 Sq.Mm 208 L ) 2 X 4 Sq.Mm ( Rate Only ) 209 M ) 2 X 2.5 Sq.Mm 210 N ) 2 X 1.5 Sq.Mm 211 Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In 6 Gauge Gi Wire Recess For Loop Earthing As Required. 212 Supplying And Installing Following Size Of Perforated Painted With Powder Coating M.S. Cable Trays With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With M.S. Suspenders Including Bolts & Nuts, Painting Suspenders Etc As Required. A ) 300 Mm Width X 50 Mm Depth X 1.6 Mm Thickness 213 B ) 150 Mm Width X 50 Mm Depth X 1.6 Mm Thickness 214 Providing & Fixing M.S. Structural Work Fabricated From Standard Section E.G. M.S Rounds, Angles, Channels, Plates Including Cutting To Size, Drilling, Welding Fixing And Welding To Insert Plates In Rcc Structural Members As Directed By Engineer-In-Charge Including Cutting And Making Good The Walls, Ceilings And Floors ( For Pipe Supports, Clamps Etc. ) 215 Electrical Control Panel Supply, Installation, Testing And Commissioning Of Following Swimming Pool Panel 415 V, 1 / 3 Phase And 50 Hz Power Distribution System. Thepanel Shall Be Free Standing Floor Mounting Sheet Metal Enclosed Dust And Vermin Proof Confirming To Ip-54, Compartmentalized Design Fabricated Out Of 16 Swg Sheet Steel, Painting Earthing Numbering, Danger Plate As Per Specifications And Drawings. Flush Front With Aluminium Busbars, Seperate Earth Bus Bars To Be Provided Throughout The Length Of The Panel The Incoming And Outgoing Feeder Breakers, Fuses, Indicating Lamps Etc Shall Be Accomadated In A Modular Multilier Arrangement. The Panel Shall Be Powder Coated Through 9 Tank Process. Adequate Size Cable Alley Shall Be Provided Forcable Termination.The Outgoing Feeders Inside Shall Be Connected Through Bus Bars / Flexible Cable Links. Incoming: One ( 1 ) No. 200A Tp 25 Ka Mccb With Thermomagnetic Digital Flush Mounted 0-200A Ammeter With 3 Way And Off Selection Switch With 3 Nos. 200 / 5 Amp Ct. 1 Set ( 3 Nos. ) Of Phase Indication Lamps 200A 25 Ka Tpn Aluminium Bus Bar. It Shall Be Insulated With Heat Shrinkable Sleeves And Shall Be Color Coded. Outgoing: Recirculation Pumpsix ( 6 ) Nos. Star Delta Starter Complete With Separate Single Phasing Protection Feature. On / Off Indicating Lamps, Relay, Contractors, Start / Stop Push Button, Auto / Manual Selector Switch, Sufficient Nos Of Potential Free Spare Contacts, Etc For Suitable Hp3 Nos. 6Amp Dp Mcb Of Suitable Rating With Correct Thermal Range Suitable For Chemical Dosing3 Nos. Toggle Switch For Doser3 Nos. 6Amp Dp Mcb Of Suitable Rating With Correct Thermal Range Suitable For Uv 3 Nos. Toggle Switch For Uv 1 Nos.16Amp Dp Mcb Of Suitable Rating With Correct Thermal Range Suitable For Underwater Lights 1 Nos. Toggle Switch For Led Pool Lightstotal C / O To Summary 216 Entry Water Bodypressure Sand Filtersupply, Instalation, Testing & Commissioning Of Bobbin Wound Top Mount Sand Filter Manufactured With Fiber Glass And Polyester Resin, Uv Resistance Surface, Non Corrosive Material, Complete With 6-Way 2 Multiport Valve With Filter Connection / Inter-Connecting Piping, Pressure Gauge, Water Drain / Empty Drain For Filter.Including Corse & Fine Sand Media For Filter As Per Approved Calculation Capacity15000 Ltrs / Hr Design @35000Ltrs / Sqm / Hr. Diameter750 Mm 217 Filter Re-Circulation Pumpsupply, Instalation, Testing & Commissioning Of Self Primingpumps With Plastic Body, In Built Strainer Basket, Impeller In Ppo, Motor Shaft In Stainless Steel Aisi-420, Mechanical Seal In Sic / Graphite And Steatite, Motor Housing In Aluminium, Withmotor -2800Rpm, F Class Insulation, Protection Ip-55. ( 1W+1S ) Capacity15000 Ltrs / Hr Head 12 Mtrhp 2.0, Three Phase 218 Fountain Re-Circulation Pump Single Stage High Speed Horizontal Centrifugal Monobloc With Volute Type Delivery Casing Pool Recirculation Submersible Pump, Delivery Casing & Motor Body In Ci, Motorshafts In Carbon Steel, Impeller In Ci Withmotor Hp7.5, Three Phase 219 Single Stage High Speed Horizontal Centrifugal Monobloc With Volute Type Delivery Casing Pool Recirculation Submersible Pump, Delivery Casing & Motor Body In Ci, Motorshafts In Carbon Steel, Impeller In Ci Withmotor Hp2.0, Single Phase 220 Swimming Pool U.V. Sterlizer Supply, Instalation, Testing & Commissioning Of U.V. Sterlizer With S.S. Housing Outside, U.V. Lamp, Glass Tube And All Other Accessories With Cleaning Arrangement, Supports, Inlet Outlet Connection With Bypass Arrangement Including S.S. Cabinet With Glass Door Of Suitable Size To House The U.V. Sterlizer Complete With Required Accessories. Flow Rate = 20000 Ltr / Hrworking Pressure = 2.5 Kg / Sqmuv Lamp Wattage = 40 W 221 Chlorine Tablet Feedersupply, Instalation, Testing & Commissioning Of Chlorine Tablet Feeder With Accessories Capacity = 4.5 Kg 222 Stainless Steel Drain Supply, Instalation, Testing & Commissioning Ofstainless Steel Drain Grating Plate Made Out Of 316 Quality S S Plates With Suitable Supporting Frame And Of Following Sizes And Having Holes Of Required Size For Drainout Chamber.Size 200X200 Mm 223 Fountain Nozzlesupply, Instalation, Testing & Commissioning Of Brass Crome Plated Gyserjet Nozzle With 1 Connection With Required Accessories. 224 Suction Inlets ( Vacuum Points ) Supply, Instalation, Testing & Commissioning Of Abs White Plastic Suction Port / Vacuum Nozzle With 2 Inch Solvent Cement Connection 225 Supply Of12volt 12W Under Water Stainless Steel 316 Ring Underwater Led Lightstype Led Warm White Light ( Ip 68 ) Including All Required Assessories & Making Connection As Required. With 2 Mtr Power Cord.For Fountain Nozzle 226 Power Supplysupply, Instalation, Testing & Commissioning Oftransformer For Led Lights 12V Dc, 30 Amp 227 Supply, Instalation, Testing & Commissioning Ofrgb Programmer For Led Lights. 228 Deck Boxsupply, Instalation, Testing & Commissioning Of Abs White Plastic Deck. 229 Upvc Pipes Providing And Fixing Upvc Pressure Pipes ( 10Kg / Cm2 ) With Plain Socket Suitable For Solvent Cement Jointing Conforming To Is:4985 / 2000 & Fittings Conforming To Is 7834 / 87.Cut To Required Lengths Including All Necessary Fittings And Specials Such As Bends, Tees, Unions, Reducers, Flanges And Plugs Etc. The Pipes & Fittings Shall Be Tested To A Pressure Of 10 Kg / Sq.Cm.A ) 32 Mm Dia 230 50 Mm Dia 231 63 Mm Dia 232 75 Mm Dia 233 90 Mm Dia 234 110 Mm Dia 235 160 Mm Dia ( Rate Only ) 236 200 Mm Dia ( Rate Only ) 237 Ball Valve Providing And Fixing Pvc Lever Operated Ball Valve Of Full Flow With Setting And Gland Of Superior Quality Having Minimum Ball Working Pressure Of 10 Kg / Cm2 With Union, Flanges Where As Required.A ) 32Mm Dia ( Rate Only ) 238 40Mm Dia ( Rate Only ) 239 50Mm Dia 240 63Mm Dia 241 75Mm Dia 242 90Mm Dia ( Rate Only ) 243 Butterfly Valveproviding And Fixing Upvc Butterfly Valves. Tested To A Pressure Not Less Than10 Kg / Sq.Cm. Including Rubber Gasket, Flanges, Nuts, Bolts, Washers Complete As Required.A ) 90 Mm Dia ( Rate Only ) 244 110Mm Dia 245 160 Mm Dia ( Rate Only ) 246 200 Mm Dia ( Rate Only ) 247 Non Return Valve Providing And Fixing Pvc Ball Type Or Spring Loaded Non Return Valve With Setting And Gland Of Superior Quality Having Minimum Working Pressure Of 10 Kg / Cm2 With Union, Flanges Where As Required. 50Mm Dia ( Rate Only ) 248 63Mm Dia 249 75Mm Dia 250 Providing And Fixing Of Upvc Wafer Check Valve Non-Return Valves ( Pn 10 ) Complete With Matching Flanges, Rubber Insertion, Nuts, Bolts And Washer Etc. Of Following Sizes. A ) 75Mm Dia ( Rate Only ) 251 90 Mm Dia 252 110 Mm Dia 253 Puddles Sleeve Supply & Fixing Of Following Sizes Of Heavy Duty Pvc Puddle Flanges ( Upvc Pipe ( 10 Kg / Cm2 ) Fixed With Flanges, Length 400 To 600 Mm Length ) On The Wall Of Plantroom, Balancing Tank And The Water Body Walls & Slab ( As Required ) . To Be Laid In Between The Steel Reinforcement Before Rcc. Does Not Include Any Civil Work. A ) 32 Mm Dia ( Rate Only ) 254 50Mm Dia ( Rate Only ) 255 Supply, Laying, Testing And Commissioning Of Ss 304 Grade 200Mm Dia Pump Delivery Header With 1 Nos 200Mm Dia Flange Connection For Filter Inlet Header, 1 No. 160 Mm Dia Flange Connection For Drain Pipe & 4 No. 160Mm Dia Flange Connection For Pump Delivery. 256 Supply, Laying, Testing And Commissioning Of Following Size Pvc Insulated Sheathed Copperconductor 1100 V Grade Unarmoured Cable With Required Size Of Sleeves Complete As Required. A ) 4 X 16 Sq.Mm 257 4 X 2.5 Sq.Mm 258 3 X 4 Sq.Mm 259 2 X 6 Sq.Mm 260 2 X 4 Sq.Mm ( Rate Only ) 261 2 X 1.5 Sq.Mm 262 Providing & Fixing M.S. Structural Work Fabricated From Standard Section E.G. M.S Rounds, Angles, Channels, Plates Including Cutting To Size, Drilling, Welding Fixing And Welding To Insert Plates In Rcc Structural Members As Directed By Engineer-In-Charge Including Cutting And Making Good The Walls, Ceilings And Floors ( For Pipe Supports, Clamps Etc. ) 263 Electrical Control Panelsupply, Installation, Testing And Commissioning Of 415 V, 1 / 3 Phase And 50 Hz Motor. The Switchboard Cubical Indoor Type Made Of 16 Swg Crca Sheet Painted With Powder Coated Paint Of Siemens Grey Shade. The Cubical Is Wall Mounted With Dust & Vermin Proof Construction With Inter Connection. It Comprise With The Following:A ) One Incoming Mains Of 63 Amps. Mccb – Tp, Schneider B ) One No. 0 – 600 V Digital Voltmeter, Mecon Make 96 Sq.Mm With Voltage Selector Switch. Make. C ) Three Phase Led Type Indicating Lights For Incoming Mains. D ) One No. Ct Operated 0 – 60 / 5 A Digital Ammeter, Mecon E ) Two No. Star Delta Starter Schneider Make With On / Off Push Button And On / Off Indication Light F ) Two No. Star Delta Starter Schneider Make With On / Off Push Button And On / Off Indication Light G ) Four No. Auto / Manual Selector Switches, Salzer Make H ) One No. Mcb Dp 6 Amps. For U / V System, Schneider Make. I ) One No. Toggle Switch For U / V System, Hsd Make. J ) One No. Mcb Sp 6 Amps. For Smps Dc Power Supply For Led Light, Schneider Make. K ) One No. Toggle Switch For Led Pool Lights, Hsd Make.Total C / O To Summary 264 Pond Aerationsupply, Instalation, Testing & Commissioning Of Surface Aerating Fountain With Pump, Float, Spray / Fountain Nozzle, Conrtol, Lights And Cable, Pump Capacity 1-3 Hp The Aerator Shall Be A Floating 265 Supply, Instalation, Testing & Commissioning Of Surface Aerating Fountain With Pump, Float, Spray / Fountain Nozzle, Conrtol, Lights And Cable, Pump Capacity 5-7.5 Hp The Aerator Shall Be A Floating 266 Supply, Instalation, Testing & Commissioning Of Surface Aerating Fountain With Pump, Float, Spray / Fountain Nozzle, Conrtol, Lights And Cable, Pump Capacity 10 Hp The Aerator Shall Be A Floating 267 Supply, Instalation, Testing & Commissioning Of Surface Aerating Fountain With Pump, Float, Spray / Fountain Nozzle, Conrtol, Lights Ss Frame And Cable, Pump Capacity 10 Hp The Aerator Shall Be A Floating 268 Miscellaneous Item ( Hanging Wire Etc ) Total C / O To Summary 269 Golf Course Water Bodies / Ponds Stpwater Supply:Making Connection Of G.I. Distribution Branch With G.I. Main Of Following Sizes By Providing And Fixing Tee, Including Cutting And Threading The Pipe Etc. Complete : A ) 25 To 40 Mm Nominal Bore 270 B ) 50 To 80 Mm Nominal Bore 271 Fixing Water Meter And Stop Cock In G.I. Pipe Line Including Cutting And Threading The Pipe And Making Long Screws Etc. Complete ( Cost Of Water Meter And Stop Cock To Be Paid Separately ) . 272 Brass Fittings Providing And Fixing Gun Metal Gate Valve With C.I. Wheel Of Approved Quality ( Screwed End ) :A ) 25 Mm Nominal Bore 273 B ) 20 Mm Nominal Bore 274 C ) 32 Mm Nominal Bore. 275 D ) 40 Mm Nominal Bore 276 E ) 50 Mm Nominal Bore 277 F ) 65 Mm Nominal Bore 278 G ) 80 Mm Nominal Bore 279 Providing And Fixing Ball Valve ( Brass ) Of Approved Quality, High Or Low Pressure, With Plastic Floats Complete : A ) 15 Mm Nominal Bore 280 B ) 20 Mm Nominal Bore 281 C ) 25 Mm Nominal Bore 282 Providing And Fixing Gun Metal Non- Return Valve Of Approved Quality ( Screwed End ) :A ) 25 Mm Nominal Bore Horizontal 283 Vertical 284 B ) 32 Mm Nominal Borehorizontal 285 Vertical 286 C ) 40 Mm Nominal Bore Horizontal 287 Vertical 288 D ) 50 Mm Nominal Bore Horizontal 289 Vertical 290 E ) 65 Mm Nominal Bore Horizontal 291 Vertical 292 F ) 80 Mm Nominal Borehorizontal 293 Vertical 294 Providing And Fixing Brass Ferrule With C.I. Mouth Cover Including Boring And Tapping The Main :Providing And Fixing Brass Ferrule With C.I. Mouth Cover Including Boring And Tapping The Main :15 Mm Nominal Bore 295 Providing And Fixing Brass Ferrule With C.I. Mouth Cover Including Boring And Tapping The Main :Providing And Fixing Brass Ferrule With C.I. Mouth Cover Including Boring And Tapping The Main :15 Mm Nominal Bore 296 25 Mm Nominal Bore 297 C.I. / Ductile Iron Pipes & Specialsproviding And Laying S&S C.I. Standard Specials Such As Tees, Bends, Collars, Tapers, Caps Etc. ( Heavy Class ) : A ) Up To 300 Mm Dia 298 B ) Over 300 Mm Dia 299 Providing And Laying Flanged C.I. Standard Specials Such As Tees, Bends, Collars, Tapers, Caps Etc., Suitable For Flanged Jointing As Per Is : 1538 :A ) Up To 300 Mm Dia 300 B ) Over 300 Mm Dia 301 Providing And Laying S&S Centrifugally Cast ( Spun ) Iron Pipes ( Class La ) Conforming To Is - 1536 :A ) 100 Mm Dia Pipe 302 B ) 125 Mm Dia Pipe 303 C ) 150 Mm Dia Pipe 304 D ) 200 Mm Dia Pipe 305 E ) 250 Mm Dia Pipe 306 Providing Lead Caulked Joints To Spun Iron Or C.I. Pipes And Specials, Including Testing Of Joints But Excluding The Cost Of Pig Lead : A ) 100 Mm Diameter Pipe 307 B ) 125 Mm Diameter Pipe 308 C ) 150 Mm Diameter Pipe 309 D ) 200 Mm Diameter Pipe 310 E ) 250 Mm Diameter Pipe 311 Providing Flanged Joints To Double Flanged C.I. / D.I. Pipes And Specials, Including Testing Of Joints : A ) 100 Mm Diameter Pipe 312 B ) 125 Mm Diameter Pipe 313 C ) 150 Mm Diameter Pipe 314 D ) 200 Mm Diameter Pipe 315 E ) 250 Mm Diameter Pipe 316 C.I. Sluice Valves / Fire Hydrants & Fixturesproviding And Fixing C.I. Sluice Valves ( With Cap ) Complete With Bolts, Nuts, Rubber Insertions Etc. ( The Tail Pieces If Required Will Be Paid Separately ) :A ) 100 Mm Diameterclass I 317 Class Ii 318 B ) 150 Mm Diameter Class I 319 Class Ii 320 200 Mm Diameter Class I 321 Class Ii 322 250 Mm Diameterclass I 323 Class Ii 324 300 Mm Diameter Class I 325 Class Ii 326 Constructing Masonry Chamber 60X60x75 Cm Inside, In Brick Work In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) For Sluice Valve, With C.I. Surface Box 100Mm Top Diameter, 160 Mm Bottom Diameter And 180 Mm Deep ( Inside ) With Chained Lid And Rcc Top Slab 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ) , I / C Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40 Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) 12 Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design : With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 327 Constructing Masonry Chamber 90X90x100 Cm Inside, In Brick Work In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) For Sluice Valve, With C.I. Surface Box 100 Mm Top Diameter, 160 Mm Bottom Diameter And 180 Mm Deep ( Inside ) With Chained Lid And Rcc Top Slab 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , I / C Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40 Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 ( 1 Cement 3 Coarse Sand ) 12 Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design : With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 ( Rate Only ) 328 Constructing Masonry Chamber 120X120x100 Cm Inside, In Brick Work In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) For Sluice Valve, With C.I. Surface Box 100 Mm Top Diameter, 160 Mm Bottom Diameter And 180 Mm Deep ( Inside ) With Chained Lid And Rcc Top Slab 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , I / C Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40 Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) 12 Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design : With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 329 Constructing Masonry Chamber 60X60x75 Cm, Inside In Brick Work In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) For Fire Hydrants, With C.I. Surface Box 350X350 Mm Top And 165 Mm Deep ( Inside ) With Chained Lid And Rcc Top Slab 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , I / C Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand:10 Graded Stone Aggregate 40 Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) 12 Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design : With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 ( Rate Only ) 330 Air Valve & Water Meter ( Bulk Type ) : Providing And Fixing C.I. Double Acting Air Valve Of Approved Quality With Bolts, Nuts, Rubber Insertions Etc. Complete ( The Tail Pieces, Tapers Etc If Required Will Be Paid Separately ) :50 Mm Dia 331 80 Mm Dia 332 100 Mm Dia 333 Providing And Fixing Enclosed Type Water Meter ( Bulk Type ) Conforming To Is : 2373 And Tested By Municipal Board Complete With Bolts, Nuts, Rubber Insertions Etc. ( The Tail Pieces If Required Will Be Paid Separately ) :150 Mm Dia Nominal Bore 334 200 Mm Dia Nominal Bore 335 Providing And Fixing C.I. Dirt Box Strainer For Bulk Type Water Meter With Nuts, Bolts, Rubber Insertions Etc. Complete Conforming To Is : 2373 :80 Mm Dia 336 100 Mm Dia 337 150 Mm Dia 338 200 Mm Dia 339 Providingandlayings&Sc.I.Standardspecialssuitablefor Mechanical Jointing As Per Is : 13382 :Up To 300 Mm Dia 340 Filter Feedpump :Providingand Fixing Vertical, Inline Multistage Centrifugalpumpingset ( Complete Manufactured Skid-Mounted Arrangement With Manifold And Accessories ) Withstainlesssteelss-304Stage Casingandss-304Impellerswith Stainless Steel Shaft As Per Iec Standards And Gjl250 Cast Iron Suction & Discharge Casing, Connected To Tefc Ventilated Induction Motor Of 2 Pole, 2900 Rpm, Suitablefor 400 / 440 Volts, 3 Phase, 50 Hz A.C. Supply With Pressure Gauge And With Gunmetal Isolationcocks, Vibrationelimination Pads Etc. Complete With Base And Frame, Nuts And Boltsandnecessary Rcc Foundations As Per Requirementasper Instructionsandpumpshallhave Following Duty: A ) .No. Ofpumps: 3 ( 2 Working + 1 Standby ) B ) .Capacity :2000 Lpmc ) .Head :35 Md ) .Capacity :2000 Lpm E ) .Hp ( Motors ) : 75 Hp 341 Pressure Filter ( Domestic Water ) :Providing And Fixing Vertical Dual Media Pressure Filter ( Comprising Of Minimum 300Mm Bed Depth Of Anthracite And Support Media And Minimum Height On Straight 2500Mm ) Fabricated From High Performance M.S Plate Of Minimum 10Mm Thick For Shell & 12Mm Thickfor Dished Ends ( Quality Of Steel As Per Is:2062 Grade B, Thickness As Per Asme Section 8 ) Internally Treated With Coal-Tar Epoxy, Complete With Air Scouring, Collection System Complete With Initial Charge Of Media, M.S Facepiping, Valves, Accessories, External Painting With 2 Coats Of Red Oxide Primer And Enamel Paint, Testing And Commissioning Complete. ( Tested To 5.0 Kg / M2 ) A ) .Discharge : App.120000 Lph ( Each ) B ) .Filtration Rate : 24, 500 Lit. / M2 / H C ) .Each Suggested Dia App.:As Per Manifacture Detail 342 Water Softener:Providing And Fixing ‘Cation’ Ion Exchange Water Softener Fabricated From Minimum 10Mm Thick M.S. Plateon Min. Shell And 12Mm Thick M.S. Plate On Dished Ends ( Quality Of Steel As Per Is:2062 Grade B, Thickness As Per Asme Section 8 ) Complete With Initial Charge Of Filter Media And Ion Exchange Resins, Face Piping Accessories, Diaphragm Valves Of Approved Specifications, Hdpe Brine Tank Of Min. 500 Liters, Piping Testing And Commissioning Complete With Resins Of Approved Quality And Make And Regeneration Assembly Complete With Valves, Ejector, Brine Suction Valves And Piping. ( Bidder Must Indicate Type And Quantity Of Resin Used And Quantity Of Salt Required Per Regeneration ) . All Internal Parts Of The Softener Shall Be Rubber Lined As Per Approved Specifications.A ) .Minimum Expected Rate Of Flow:App.32, 000 Lph B ) .Total Soft Water To Be Produced Between Two Regenerations: App. 256 Cu.M C ) .Expected Raw Water Hardness : App. 450-500 Ppmd ) .Expected Treated Water Hardness: Less Than 5 Ppm ( Zero Commercial Hardness ) E ) .Max. Working Pressure: 4 Kg / Cm2 343 Cubical Panel Board - Plumbing : Supply, Installation, Testing And Commissioning Of Cubical Type Sectionalised Floor Standing Switch Board Of 31 Mva Fault Capacity At 415 V Complete With 3.5 Strip, 160 A Capacity Aluminium Bus - Bar Electrolytic Grade, Cable Alley, Switchgears Of Following Capacity & As Per Specifications.Incomer : 600 A Tp Mccb With Heavy Duty Solid Neutral Link With ( 0-100A ) Ammeter With 3 Ct And Selector Switch, ( 0 - 500 V ) Voltmeter With Selector Switch, Phase Indication Light Withprotection Fuse. - 01 Setoutgoings : I ) For 5 X 75 Hp Domestic Water Fixed Speed Hydroneumatic Pumps ( 1 Duty + 1 Stand By ) Ii ) For 2 X 5 Hp Sump Pump ( 1 Duty + 1 Stand By ) 150 A Tp Mcb With 40 A Dol Starter, Overload Relay, 96 Mm ( 0-40A ) Ammeter With Single Ct, Start / Stop Push Buttons, On / Off / Trip Indication Lights With Protection Fuse, Single Phase Preventer. - 01Set. 40A Tp Mcb With 25 A Dol Starter, Overload Relay, 96 Mm ( 0-25A ) Ammeter With Single Ct, Start / Stop Push Buttons, On / Off / Trip Indication Lights With Protection Fuse, Single Phase Preventer. - 01 Set.
BRR : 7635527
Tender For Sivagangai Dccb H.O. Admin Building; 1 Earth work excavation for foundation in all classes of soils (including soft rock)except hard rocks and refilling of foundation and basement, carting away the excess soil as directed. 2 Laying of P.C.C. 1:5:10 for foundation using using 40mm hard broken aggregate including the cost of materials, transport charge, labour for curing all leads and lifts etc. 3 Pouring of R.C.C 1:1.5:3 M20 grade concrete for foundation using 20mm hard broken aggregate including the cost of materials, admixture, transport, labour charges on barbending, Fabrication, shuttering, Centering, Concreting etc., but excluding the cost of steel. 4 Footing: 5 Plinth Beam: 6 Columns: 7 Tie Beam: 8 Floor Beam: 9 Lintel Beam: 10 Stilt Roof Beam: 11 First Floor Roof Beam: 12 Second Floor Roof Beam: 13 Third Floor Roof Beam: 14 Headroom Roof Beam: 15 Floor Slab: 16 Stilt Floor Roof Slab: 17 First Floor Roof Slab: 18 Second Floor Roof Slab: 19 Third Floor Roof Slab: 20 Headroom Roof Slab: 21 Safe Room: 22 Staircase: 23 Compound Wall: 24 Sump: 25 Septic Tank 26 Filling of excavated earth and gravel for basement in layers not more than 15 cm including the cost of Gravel, transport charges,labour for filling, watering, ramming with surface vibrator, consolidating etc., 27 Brick work in C.M 1 :5 for using First Class flyash bricks for substructure including the cost of all materials, transport, hire charge, scaffolding, charge for curing etc. 28 Brick work in C.M 1 :5 for using First Class Burnt Clay Chamber / Wire Cut bricks for supersturcture including the cost of all materials, transport, hire charge, scaffolding, charge for curing etc. 29 Plastering in C.M 1 :5 including the cost of all materials, transport, hire charge for scaffolding, charge for curing, admixtureetc. 30 Ceiling Plastering in C.M 1 :3 including the cost of all materials, transport, charge for curing, admixtureetc. 31 Outer Plastering in C.M 1 :5 including the cost of all materials, transport, charge for curing, admixtureetc. 32 Hire charge for steel prop scaffolding for ceiling plastering including the cost of all labour for installation, dismantling and tranport charges. 33 Hire charge for steel prop scaffolding for outer plastering including the cost of all labour for installation, dismantling and tranport charges. 34 Flooring in cm 1 :3 using Double charged virtified tiles 600mmx 600mm x 8mm including cost of all material, labour& lead lift charges. (The make and brand of the tiles should be approved by the authority before use on works) 35 Bathroom Flooring in cm 1 :3 using virtified tiles with 2-3mm spacers and filling the joints with MYK Lacticrete SP-100 epoxy grout including cost of all material, lead lift & labour charges.(The make and brand of the tiles should be approved by the authority before use on works) 36 Waterproofing of bathroom by applying of 2 coats of Fosroc brushbond RFX after cleaning up of the surface with wire brush and moisting the surface before application including cost of all material & labour charges. 37 Bathroom Filling using broken AAC blocksin cm 1 :8 upto required depth and placing of drain pipes with slits including cost of all material, lead lift & labour charges. 38 Supplying of UPVC Windows (Open Type), Ventilator as per Indian Standards including cost of all materials,fitting & transportation charges etc., 39 Fixing of Rolling Shutter (Flat Type) with Gear per Indian Standards including cost of all materials,fitting & transportation charges etc., 40 Providing of S.S Hand rails using 304L grade Stainless steel pipes including the cost of all materials and labour., 41 Colour wash on the plastered surface after applying 2 coats of wall putty, 1 coat of primer, 2 coats of emulsion (First quality)including cost of all materials & labour charges Etc., 42 A1-WIRING 43 Supply, Installation, testing and commissioning of surface/concealed type of point wiring with modular type switches, sockets and all materials as per the point wiring chart. The item including cost of supply and installation of 19mm(in wall) or 25mm(ceiling/wall) dia PVC conduits, couplers, junction boxes, bends, ceiling/wall plates, metal boxes, switches, sockets, draw boxes & top cover plate (3mm hylam sheet), 3 run of 1.5sq.mm FRLS copper wires, bakelite connectors, crimping type ferrules, copper lugs, brass cup washers & brass screws, clamps & screws and bolt & nuts etc. All the points shall be terminated with 300mm length of additional wires along with connector terminal blocks. The item including necessary chipping/cutting the wall and making good the same in case of recessed conduit as required. All complete as per specifications, drawings and / or as directed by the Engineer. 44 One light / exhaust fan / wall mounting fan point controlled by one No. 1-way 6 Amps switch. (upto 6m) 45 One fan point (with regulator) controlled by one No. 1-way 6 Amps switch. The item including cost of fan hook with metal box, top round sheet/plate and 2M stepped regulator etc. (upto 6m) 46 One light / wall mounting point controlled by two Nos. 2-way 6 Amps switch. (upto 9m) 47 One 6A dependent 5-pin socket point controlled by one no of 6A switch. (switch & socket are mounted in a dependent switch box) 48 One 16A dependent 5-pin socket point controlled by one no of 16A switch. (switch & socket are mounted in a dependent switch box) 49 One 6A independent 5-pin socket point controlled by one no of 6A switch. (switch & socket are mounted in a independent switch box) 50 One 16A 5-pin socket point controlled by one 16A switch . (switch & socket are mounted in a seperate switch box ) 51 One 20A 5-pin socket point controlled by one 32A switch with indicator. (switch & socket are mounted in a seperate switch box for AC) 52 A2-Main Switch Board Panal 53 Supply, Erection, Testng and Commissioning of Indoor type Main Panel, Floor mounting tyoe, dust and vermin proof by construction of 14/16 swg CRCA sheets Compartmentalised, modular type IP 42 Protection with powder coated panel as specification below. 54 Digital Meter with Indicators Buzzer to be provided. 55 EB Incomer : 1 No - 125A, 4P, MCCB, 25KA Rating 56 DG Incomer : 1 No - 63A, 4P, MCB, 10KA Rating 57 ATS : 1 No - 125 A, 4P, ATS (Socomec - ATYSS) 58 Necessary single phasing preventer, LVMs and control contactors are giving due preference to the EB supply 59 Necessary timers are provided in all outgoings for ON DELAY feature at EB and DG supplies while changeover from one source to another 60 125A Aluminium Bus Bar 61 Outgoing : 40A, 4P, MCB, 10KA Rating - {Ground Floor Automation DB} 62 40A, 4P, MCB, 10KA Rating - {First Floor Automation DB} 63 40A, 4P, MCB, 10KA Rating - {Second Floor Automation DB} 64 63A, 4P, MCB, 10KA Rating - {Ground Floor Automation DB} 65 63A, 4P, MCB, 10KA Rating - {First Floor Automation DB} 66 63A, 4P, MCB, 10KA Rating - {Second Floor Automation DB} 67 63A, 4P, MCB, 10KA Rating - Terrace VTPN DB 68 32A, DP, MCB, 10KA Rating - Main [ELDB] 69 32A, DP, MCB, 10KA Rating - Main UPS DB 70 63A, 4P, MCB, 10KA Rating - {Lift} 71 63A, 4P, MCB, 10KA Rating - SPAREA 3 Nos 72 25A, DP, MCB, 10KA Rating - Ground Floor A/C DB 73 25A, DP, MCB, 10KA Rating - Second Floor A/C DB 74 25A, DP, MCB, 10KA Rating - Third Floor A/C DB 75 25A, DP, MCB, 10KA Rating - Bore Well 76 25A, DP, MCB, 10KA Rating - Sump 77 25A, DP, MCB, 10KA Rating - Gate Motor 78 25A, DP, MCB, 10KA Rating - Outdoor Utility DB 79 25A, DP, MCB, 10KA Rating - SPAREA 4 Nos 80 Cabling Top & Bottom Entry, All MCCBs shall be with Operating Handle 81 A3-Supply, Installation, testing and commissioning of surface/concealed type of main circuit wiring from panel/DB to DBs, DB to switch boxes and switch box to other switch boxes using 1100V grade PVC insulated multistranded FRLS copper wires, to be drawn through existing conduits. The items including cost ofbakelite connectors, crimping type ferrules, copper lugs, brass cup washers & brass screws, clamps & screws and bolt & nuts etc. The item including necessary chipping/cutting the wall and making good the same in case of recessed conduit as required. All complete as per specifications, drawings and / or as directed by the Engineer. 82 3 runs of 1.5 sq.mm. FRLS copper wiring through PVC conduits. 83 2 runs of 2.5 sq.mm. & 1 run of 1.5 sq.mm. FRLS copper wiring through PVC conduits. 84 2 runs of 4.0 sq.mm. & 1 run of 2.5 sq.mm. FRLS copper wiring through PVC conduits. 85 A4-Supply, Installlation of surface/recessed type PVC/MS, rigid/flexible, conduits of the following sizes with required couplers, junction boxes, bends, ceiling/wall plates, metal boxes, draw boxes & top cover plate (3mm hylam sheet), clamps, screws, bolt & nuts and necessary fixing accessories etc. The item including necessary chipping/cutting the wall and making good the same in case of recessed conduit as required. All complete as per specifications, drawings and / or as directed by the Engineer: 86 20mm dia 2mm thick rigid PVC conduits. 87 25mm dia 2mm thick rigid PVC conduits. 88 32mm dia 2mm thick rigid PVC conduits. 89 20mm dia 1.6mm thick rigid PVC conduits. 90 25mm dia 1.6mm thick rigid PVC conduits. 91 B1-DISTRIBUTION BOARD 92 Supply, Installation, testing and commissioning of three phase, phase segregated, compartmentalised 8 way TPN MCB DB WITH PPI KIT Double door type with IP 43 powder coated. 93 Incomer - 63A, 4P, MCB - 1 No 94 Sub Incomer - 63A, dp, RCCB (30mA) - 3 Nos 95 Outgoings - 6A, SP, MCB - 8 Nos 96 Outgoings - 16A, SP, MCB - 8 Nos 97 Outgoings - 20A, SP, MCB - 2 Nos 98 PPI KIT - 1 No 99 Including all interconnections and other associated fixing accessories and all as required as per the site conditions 100 8way 101 B2-Supply, Installation, testing and commissioning of following ways of surface/flush mounting, SPN MCB DBs of sheet steel, powder coated, IP43 protection, metal door and cable end box etc. The item including terminal connectors for all incoming and outgoing circuits, duly pre-wired with suitable size of FRLS PVC copper wires upto terminal blocks, tinned copper bus bar of suitable rating, neutral links, earth bars, detachable gland plate, interconnections by using crimping type ferrules & copper lugs, and engraving of laminated as-built circuit drawings in the door inside etc. The item including necessary chipping/cutting the wall and making good the same in case of flush mounting as required. All complete as per specifications, drawings and / or as directed by the Engineer: 102 12way 103 B3-Supply, Installation, Testing and Commisioning of single phase, 12way SPN MCB DB Double Door typr, with IP 43 powder coated 104 Incomer - 25A, DP, MCB - 1 No 105 Outgoings - 10A, Single Pole - 8 Nos 106 Including all interconnections and other associated fixing accessories & all as requited as per the site conditions 107 4way 108 C1-LUMINAIRES AND FIXTURES 109 Supply, Installation, testing and commissioning of following sizes of ceiling fan/wall fan, all complete as per specifications, drawings and / or as directed by the Engineer. 110 1200mm sweep 111 2 x 2 LED Lamp 112 D1-LT PANELS 113 Supply,Installation, testing and commissioning of 415V Metering board fabricated with 16G CRCA sheet steel, complete with 100Amps cut-out fuse carriers and outgoing as 125 Amps fuse switch unit. The item including the provision for multifunction meter and proper sealing arrangements etc. all complete as required by TNEB. 114 E1-LT CABLING 115 Supply, Laying, testing and commissioning of following 1.1KV grade multicore aluminium/copper conductor XLPE/PVC insulated GI round(upto 10sqmm) / flat(16sqmm and above) armoured PVC sheathed cables (without any cable joint) drawn through tray or steel supports or clamping on the ceiling/wall or pre-excavated / pre-formed trenches or GI pipe sleeves / hume pipes with suitable clamping arrangement and fixing accessories, cable routemarkers, cable ties, identification tags etc. all complete as per specifications, drawings and / or as directed by the Engineer. 116 3.5C x 16 sq.mm Copper Ar. XLPE cable 117 E2-Supply, Termination of the following sizes of 1.1KV XLPE/PVC insulated Al/Cu conductor cables with single compression brass cable glands and tinned copper lugs including gland earth clips, adequate size of bare copper wire connecting to the main bus bars etc. all complete as per specifications, drawings and / or as directed by the Engineer. 118 3.5C x 16 sq.mm Aluminium Ar. XLPE cable 119 G1-EARTHING 120 G2-Supply, Installation, testing and commissioning of earth station comprising of 50mm outer diameter and 3 meter length of GI earth electrode, including approved clamps, bolts & nuts, 450m x 450mm brick masonary chamber, heavy duty CI cover, homogeneous layers of earth enhancing backfilling materials (bentonite/fly ash) are placed around the earth pipe as per standards (IS 3043), the items including cost of excavation, backfilling of earth etc. all complete as per specifications, drawings and / or as directed by the Engineer. 121 25x3mm copper flat. QRO 122 8 SWG copper wire. 123 H1-TELEPHONE SYSTEM A) Supply, Fixing of RJ-11 modular type telephone outlet mounted on suitable zinc-passivated metal box complete with metal box, front plate, screws and fixing accessories etc.,The item including necessary chipping/cutting the wall and making good the same incase of recessed mounting and all complete as per specifications, drawings and / or as directed by the Engineer. 124 B) Supply, Laying and termination of high quality 2pair 0.5sq.mmcable preferably with FR PVC insulation to be laid in existing 19mm/25mm dia 1.6mm/2mm thick PVC pipe from individual telephone to krone connector box.The item including necessary chipping/cutting the wall and making good the same in case of recessed conduit as required. All complete as per specifications, drawings and / or as directed by the Engineer. 125 I- DATA & CCTV SYSTEM a) Supply, Fixing of RJ-45 modular type telephone outlet mounted on suitable zinc-passivated metal box complete with metal box, front plate, screws and fixing accessories etc.,The item including necessary chipping/cutting the wall and making good the same incase of recessed mounting and all complete as per specifications, drawings and / or as directed by the Engineer. 126 b) Supply, Laying and termination of high quality CAT 6 cable preferably with FR PVC insulation to be laid in existing 19mm/25mm dia 1.6mm/2mm thick PVC pipe from individual telephone to krone connector box. The item including necessary chipping/cutting the wall and making good the same in case of recessed conduit as required. All complete as per specifications, drawings and / or as directed by the Engineer. 127 J1-TELEVISION SYSTEM 128 a) Supply, Fixing of modular type television socket mounted on suitable zinc passivated metal box complete with metal box, front plate, screws and required fixing accessories etc.The item including necessary chipping/cutting the wall and making good the same in case of flush mounting as required. All complete as per specifications, drawings and / or as directed by the Engineer. 129 b) Supply, Faying and termination of closed circuit television co-axial RG6 cable laid in existing 1.6mm/2mm thick 19mm/25mm dia PVC conduit & accessories from dish to individual TV.The item including necessary chipping/cutting the wall and making good the same in case of recessed conduit as required. All complete as per specifications, drawings and / or as directed by the Engineer. 130 A:SANITARY FIXTURES AND CP FITTINGS: 131 Collecting from stores fixing, testing and commissioning of glazed white vitreous wall mounted European water closetMS / CI chair brackets, fischer bolts with CP bolts / nuts and with PVC flush tank , solid plastic seat and lid with heavy duty CP hinges and rubber buffers and flap etc. The work shall include cutting making of walls and floors etc. Notes:EWC with accessories will be provided by Client necessary consumables like brass screws, CP extension nipple of approved make, dia and length, wooden plugs, white cement, sealants etc.,Only drilling machines shall be used for making the holes in the walls for fixing, no wall jumper and hammer will be allowed. 132 Supply: 133 Fixing : 134 Collecting from stores, shifting to the place of installation and fixingtesting and commissioning of glazed white colourvitreousRectangularwash basin installed below granite/ marble with CI / MSbrackets, 15mm dia CP pillar cock fitting, 32mm dia CP waste coupling with plug and chain,32mm dia CP brass bottle trap,1 nos15 mm dia- 450mm long PVC / CPcold watersupply connecting pipe, 1 no of 15mm dia CP angle stop cock forcold watersupply liness with wall flange etc., The works shall include cutting in walls and making good the walls & floors. Size of wash basin 55 x 40cm.(Granite / Marble counter will be installed by other agency) 135 Supply: 136 Fixing : 137 Collecting from stores, shifting to the place of installation and fixing, testing and commissioning ofCP health faucet consisting of: 138 CP angle stop cock with wall flange. 139 PVC flexible tube. 140 Hand operated spray unit (instant type) 141 Supply: 142 Fixing : 143 Collecting from stores, shifting to the place of installation and fixing, testing and commissioning of 15mm dia CP long body bib cock with CP wall flange etc. 144 Supply: 145 Fixing : 146 Collecting from stores, shifting to the place of installation and fixing, testing and commissioning of15mm diaCP sink cock with swinging spout (wall mounted model) for kitchen sink with CP wall flange etc. Notes: Conditions mentioned in item no.1 shall be applicable. 147 Supply: 148 Fixing : 149 Collecting from stores, shifting to the place of installation and fixingtesting and commissioning of 15mm dia CP brass angle stop cock with wall flange and 15mm dia PVC connecting pipe for aquaguard & washing machine as specified in the drawings. 150 Supply: 151 Fixing : 152 Collecting from stores, shifting to the place of installation and fixing, testing and commissioning ofCP brass concealed stop cock with adjustable wall flange for master control in first floor toilets. Notes: Conditions mentioned in item no.1 shall be applicable. 153 20 mm dia 154 Supply: 155 Fixing : 156 B : CPVC / UPVC PIPES AND FITTNGS (INTERNALAND EXTERNAL WATERSUPPLY): 157 Providing, fixing, testing and commissioning ofCPVC / jindal composite pipes confirming to ASTM standard including all CPVC / jindal composite fittings like tees, elbows, bends, unions, coupling, reducer tees, collars etc. The work shall include cutting jointing with solvent cement pressure testing the joints / pipeline for 10 kg/sq.cm hydraulic pressure, for 4 hours etc. making holes,including chasing in solid block masonry walls with groovecutting machine to required width and depth, making bores in walls,foundations and RCC slabs, making good the walls and bores in CC or CM 1:3 as applicable clearing the debris, grouting of concealed pipes, MS hooks for fixing pipes and making good the walls and floors. 158 Note: Strictly use SDR-11 grade Flow guard - CPVC pipe and fittings for internal cold water supply up to 50 mm dia. 159 Notes: Rate Quoted shall be inclusive of cost of other consumables like hacksaw blade, solvent for CPVC pipeof make IPS - Flow guardup to 50 mm dia etc. 160 INTERNAL (CONCEALED IN WALL): 161 COLD WATERSUPPLY - HI & LOW PRESSURE 162 20 mm dia(SDR-11 /COMPOSITE PIPES )Supply: 163 Fixing: 164 INTERNAL (CONCEALED IN WALL): 165 HOT WATERSUPPLY 166 Note: Strictly use SDR-11 grade Flow guard - CPVC pipe and fittings for internal hot water supply up to 50 mm dia. 167 Notes: Rate Quoted shall be inclusive of cost of other consumables like hacksaw blade, solvent for CPVC pipeof make IPS - Flow guard up to 50 mm dia etc. 168 20 mm dia (SDR-11 /COMPOSITE PIPES )Supply: 169 Fixing : 170 Providing, fixing, testing and commissioning ofCPVC & UPVC pipes confirming to ASTM standard including all CPVC & UPVC fittings like tees, elbows, bends, unions, coupling, reducer tees, collars etc. The work shall include cutting jointing with solvent cement pressure testing the joints / pipeline for 10 kg/sq.cm hydraulic pressure, for 4 hourshours etc., fixed on to the wall in vertical shafts / terrace with fabricated MS brackets of suitable size with GI U clamps, bolts, nuts and GI washers includingMS brackets including making good the walls and floors. 171 SHAFT / TERRACE & RING MAIN PIPING:COLD WATER SUPPLY - CPVC & UPVC 172 20 mm dia -(SDR-11)Supply: 173 Fixing : 174 25 mm dia -(SDR-11) Supply: 175 Fixing : 176 32 mm dia -(SDR-11) Supply: 177 Fixing : 178 40 mm dia -(SDR-11)Supply: 179 Fixing : 180 50 mm dia -(SDR-11)Supply: 181 Fixing : 182 25 mm dia- SCH 40 pumpingSupply: 183 Fixing : 184 32 mm dia- SCH 40 pumpingSupply: 185 Fixing : 186 40 mm dia - SCH 40 (gravity supply GF) Supply: 187 Fixing : 188 50 mm dia - SCH 40 (gravity supply GF) Supply: 189 Fixing : 190 HOT WATER SUPPLY& RETURN -CPVC 191 20 mm dia - SDR-11Supply: 192 Fixing : 193 25 mm dia - SDR-11Supply: 194 Fixing : 195 32 mm dia- SDR-11 Supply: 196 Fixing : 197 AC DRAIN STACK 198 32 mm dia (Type B / 6kg / sq.cm) Supply: 199 Fixing : 200 Providing, fixing, testing and commissioning ofFlow guard CPVC & UPVC pipes confirming to ASTMstandard including all CPVC & UPVC fittings like tees, elbows, bends, unions, coupling, reducer tees, collars etc. Thework shall include cutting jointing with solvent cement pressure testing the joints / pipeline for 10 kg/sq.cm hydraulic pressure, for 4 hours etc., laid burried underground. 201 UNDER GROUND BURRIED PIPING:GARDEN & PUMPING LINE 202 COLD WATER SUPPLY - UPVC 203 20 mm dia - SCH 40 Supply: 204 Fixing : 205 25 mm dia - SCH 40Supply: 206 Fixing : 207 32 mm dia- SCH 40 (pumping)Supply: 208 Fixing : 209 40 mm dia- SCH 40 (gravity supply & garden GF) Supply: 210 Fixing : 211 25 mm dia - SDR-11(GF Burried)Supply: 212 Fixing : 213 Providing, fixing, testing and commissioning ofball valves of brass body nickel plated with stainless steel ball, lever operatedand tested to 20kg / sq.cm. 214 20 mm dia Supply: 215 Fixing : 216 25 mm dia Supply: 217 Fixing : 218 32 mm dia UPVC Supply: 219 Fixing : 220 40 mm dia Supply: 221 Fixing : 222 50 mm dia Supply: 223 Fixing : 224 Providing, fixing, testing and commissioning ofslimseal flap type check valve / NRV with CI body and cast steel disc pressure rating PN-10 Kg / sq.cm make Intercalve. 225 20 mm dia Supply: 226 Fixing : 227 25 mm dia Supply: 228 Fixing : 229 32 mm dia Supply: 230 Fixing : 231 50 mm dia Supply: 232 Fixing : 233 Providing, fixing,testing and commissioning of suction `Y / pot stainer with MS flange of suitable length fabricated from 16 gauge brass sheet with 3mm slots. 234 32 mm dia Supply: 235 Fixing : 236 40 mm dia Supply: 237 Fixing : 238 50 mm dia Supply: 239 Fixing : 240 C: PVC SOIL,WASTE,VENT PIPES AND FITTINGS ( INTERNAL & EXTERNAL) 241 Providing, fixing,testing and commissioning of PVC soil, waste and vent pipe confirmingto IS 13592 of SWR quality Type B /6 kg / sq.cm pressure rated including all fittings, like Bends, Tees, Elbows, Collars, junction, offsets, access pipes, jointing withsolvent cement followed by application of leak proof adhesive like FRP paste & laid on floors inside the toilets to the required slope including making necessary bores in walls / foundations / concrete slab as applicable, making good the bores with CM 1:3 or cement concrete 1:2:4 as applicable, curing etc., complete. 242 Notes: 243 Rate Quoted shall be exclusive of cost of cement, sand and other consumables like hacksaw bladeetc. 244 INTERNAL: 245 75mm dia (Type B / 6kg / sq.cm) 246 Supply: 247 Fixing: 248 110mm dia(Type B / 6kg / sq.cm) 249 Supply: 250 Fixing: 251 Providing ,fixing,testing and commissioning of PVC soil, waste and vent pipe confirming to IS 13592 of SWR quality type B /6 kg / sq.cm pressure rated, including all fittings, like Bends, Tees, Elbows, Collars, junction, inspection doors, cowls, offsets, access pipes, jointing with rubber ring / solvent cement followed byapplication of leak proof adhesive like FRP paste, fixed to wall with properly fabricated MS bracket of suitable size, GI U clamps with bolts, nuts and GI washers complete, for soil and waste pipe lines laid in vertical shafts. 252 Notes: 253 Rate Quoted shall be exclusive of cost of cement, sand and other consumables like hacksaw bladeetc. 254 EXTERNAL : 255 75mm dia (Type B / 6kg / sq.cm) 256 Supply: 257 Fixing: 258 110mm dia (Type B / 6kg / sq.cm) 259 Supply: 260 Fixing: 261 Providing ,fixing,testing and commissioning of PVC soil and waste pipes for underground drainage line layed under the soil with required slops, confirming to IS 4985 of Agricultural series - 6 kgs / sq.cm pressure rated with necessary specials of required size jointing withsolvent followed by application leak proof adhesivesof FRP paste, including haunching / covering the joints with cement concrete 1:3:6 at all the joints and testing of joints etc. complete 262 Notes: 263 Rate is excluding for earthwork and backfilling. It shall be measured separate and paid for. 264 Rate Quoted shall be exclusive of cost of cement, sand and other consumables like hacksaw bladeetc. 265 160mm dia(6kg / sq.cm / foam core - SN8) 266 Supply: 267 Fixing: 268 Providing, fixing,testing and commissioning of PVC multi inlet floor trap of self cleansing design moulded or fabricated, if not available in size mentioned below, with or without vent armjointing withsolvent cement followed by application of leak proof adhesive like FRP paste including encasing all round fixing the floor trap in cement concrete1:2:4 ratio of size 300 x 300 mm x 250 mm height (approx) and making good the floors. 269 110mm dia inlet 75mm dia out let 270 Supply: 271 Fixing: 272 110mm dia inlet 110mm dia out let - P TRAP 273 Supply: 274 Fixing: 275 Providing and fixing CP grating of 6mm thick with rim including setting in floor with white cement mortar and making good the floor (Chilli Make). 276 Cock roch trap grating 277 125mm diaSupply: 278 Fixing: 279 Ordinary grating 280 125mm diaSupply: 281 Fixing: 282 Providing and fixing testing and commissioning of PVC waste pipe of agricultural sereis confirming to IS 4985 including all fittings like tees, elbows, bends, collars, coupling, etc jointing with solvent cement followed by application of leak proof adhesive like FRP paste laid on floors inside the toilets to the required slope including making necessary bores in walls / foundations / concrete slab as applicable, making good the bores with CM 1:3 or cement concrete as applicable, curing etc., complete. 283 Wall chasing shall be done with chasing machine to required lines and levels. 284 Rate Quoted shall be exclusive of cost of cement, sand and other consumables like hacksaw bladeetc. 285 40 mm dia (15kg / sq.cm) Supply: 286 Fixing: 287 50 mm dia (15kg / sq.cm) Supply: 288 Fixing: 289 D: PVC RAIN WATER PIPES AND FITTINGS 290 Providing ,fixing,testing and commissioning of PVC rain waterpipe confirming to IS 13592 of SWR quality 6 kg / sq.cm pressure ratedincluding all fittings, like Bends, Tees, Elbows, Collars, junction, inspection doors, cowls, offsets, access pipes, jointing with rubber ring / solvent cement followed by application of leak proof adhesive like FRP paste, fixed to wall with properly fabricated MS bracket of suitable size, GI U clamps with bolts, nuts and GI washers complete, for rain water pipe lines laid in vertical shafts. 291 75mm dia (Type B / 6kg / sq.cm) 292 Supply: 293 Fixing: 294 110mm dia(Type B / 6kg / sq.cm) 295 Supply: 296 Fixing: 297 E: OTHER PLUMBING EQUIPMENTS 298 Collecting from stores, shifting to the place of installation and fixing, testing and commissioning of Booster pump(1 to 3 HP)with pressure tank, including a set of inlet , outlet connections, ball valve, NRV,suitableflanges,, bolts, nuts GI washers, etc., complete. 299 Fixing: 300 Collecting from stores, shifting to the place of installation and fixing, testing and commissioning of Open well sub water transfer pump (1 to 3 HP) with auto level control, including a set of inlet , outlet connections, ball valve, NRV,suitableflanges,, bolts, nuts GI washers, etc., complete.for municipal water & Filter water 301 Fixing: 302 As per IS: 13592-1992, TYPE A pipes are recommended for use in ventilation pipe work and rain water application and TYPE B pipes are recommended for use in soil and waste discharge system. 303 Laying of weathering coarse in cm 1 :5 using red clay tiles including cost of all material & labour charges. 304 Laying of paver block on outer area using un-polished cement blocks of approved design over a layer of baby chips and compacting the same using plate compactor including cost of all materials and labour charges etc., 305 Supplying of TMT Steel for all RCC works including cutting, bending, tying and placing in position including cost of materials and transport. 306 Providing, fabricating & installing in position 4mm thickness 0.25mm skin aluminium composite cladding of PIONEER, ALUTECH, ALSTRONG are protected with self adhesive protection film by erecting over the wall using aluminium frames @ desired levels made with 50 x 25 x 1.2mm extruded channel sections confirming to IS-7333 mechanical properities. The frame shall be fixed on external wall surface with necessary brackets, bolt nut arrangements with screws aluminium L cleats, backer rod, wacker / dowcorning silicon sealant etc.,@all levels & heights & silicon sealant is filled in complete as per specification & design approved by the authority. 307 Front and Side Elevation 308 Designing, Fabricating, Protection, Cleaning, installing and Fixing in position Semi - Glazing System / Glass Curtain using using aluminium frames @ desired levels,The frame shall be fixed on external wall surface with necessary brackets, bolt nut arrangements with screws aluminium L cleats, backer rod, wacker / dowcorning silicon sealant etc.,@all levels & heights & silicon sealant is filled in complete as per specification & design approved by the authority. 309 Front and Side Elevation
BRR : 9407092
Tender For Construction And Development Of Infrastructure At Nakdum Bop Of 2Nd Bn Itbp .; 1 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kind of soil 2 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kind of soil 3 Earth work in excavation bymanual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. In ordinary rock. 4 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level (1:5:10) (1 Cement :5 Coarse sand :10 graded stone aggregate 40mm nominal size) 5 Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering-All work upto plinth level: 1:2:4 ( 1 Cement: 2coarse sand : 4 graded stone aggregate 20 mm nominal size) 6 Random rubble masonry with hard stone in foundation and plinth including leveling up with cement concrete 1:6:12 (1 Cement : 6 coarse sand : 12 graded stone aggregate 20mm nominal size) at plinth level with Cement mortar 1:6 (1 Cement : 6 coarse sand) 7 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size). 8 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 9 Centering and shuttering including strutting, propping etc. and removal of form for foundations, bases of columns, beams etc for mass concrete up to plinth. 10 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 11 20 mm cement plaster of mix 1:6 (1cement :6 fine sand) 12 Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 13 Providing and fixing 1mm thick M.S. sheet as shelves in steel racks with all necessary fittings complete, including applying a priming coat of approved steel primer. 14 Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigment etc., complete. 15 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, Jet pressure device, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked black solid plastic seat and lid. 16 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : 17 P/F wash basin with CI brackets 15mm CP brass pillar taps 32mm CP brass waste of standard pattern including painting of fittings and brackets, cutting and making good the walls wherever required. White vitreous china wash basin size 630 x 450mm with a single 15mm CP brass pillar tap 18 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required : 510x1040 mm bowl depth 250mm. 19 Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make: Rectangular shape 453x357mm . 20 Providing and fixing 600x120x5mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. 21 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour.600mm long towel rail with total length of 645mm, width 78mm and effective height of 88mm, weighing not less than 190gms. 22 Providing and fixing Steel peg batten with 6 Nos steel peg of approved steel grade, quality and make. 23 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. (internal work, exposed on wall) and painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality. : 15 mm dia nominal bore 24 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.: 15 mm dia nominal bore 25 Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes butwithout fittings and the base support for tank . 26 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 27 Providing and fixing CP brass stop cock 15 mm dia ( concealed) of make Parko/Kingstone/Essco confirming to IS:8931 28 Providing and fixing Nahani trap of self cleaning design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 100 mm inlet and 100 mm outlet CI Pipes of IS 3989. 29 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating stone masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 100x100 mm size P type 30 Providing and fixing soil, waste and vent pipes : 100 mm dia PVC pipe 31 Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design :Inside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets : : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 32 Providing, laying and jointing PVC (Heavy) pipes 100 mm dia nominal bore with solvent including testing of joints etc. complete including all necessary fittings. MAKE PRINCE/PRAKASH/FINOLEX/AKG /SUPREME /TIRUPATI 33 Wiring for light point/fan point/ exhaust point/ call ball point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed 20 mm PVC conduit (Polymer/Polycab/Anchor/ISI), with piano type switch (Anchor/CONA), phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 Sqmm FRLS PVC insulated copper conductor single core cable (Plaza/Havells/Anchor) etc as required.Group A 34 Wiring for circuit/sub main wiringalong with earth wire with 2x1.5 sq mm + 1x1.5 sq mm earth wire FRLS PVC insulated copper conductor, single core cable in surface/ recessed 20 mm PVC conduit (Polymer/Polycab/Anchor/ISI)as required. Wire should be of Plaza/Havells/Anchor) 35 Wiring for circuit/sub main wiringalong with earth wire with 2x4 sq mm + 1x4 sq mm earth wire FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit (Polymer/Polycab/Anchor/ISI) as required. Wire should be of Plaza/Havells/Anchor) 36 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, incuding P/F 6 pin 15/16 amps piano type socket outlet and 15/16 amps piano type switch, connections etc as required 37 Supplying and fixing PVC angle/Batten holder (Anchor/Ambit) including connectionsetc. as required. ISI Make only. 38 Supplying and fixing MCB DB 4ways (Havells) complete with connections, testing and commissioning etc as required. 39 Supplying and fixing double Pole 40 Amp, 240 volts, isolator (Havells) in the existing MCB DB complete with connections, testing and commissioning etc as required. 40 Supplying and fixing 16 Amp rating, 240/415 volts (Havells), C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc as required. Single pole 41 Supplying and fixing 18 watt LED batten fitting (Havells /Philips/Bajaj) complete 42 Wiring for light /POWER PLUG with 2X4 sq. mm FR PVC insulated copper conducter single core cable in surface/ recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with1 N0. 4Sqmm FR PVC insulated copper conducter single core cable etc as required.( Item No. 1.12A.O.R.- 2012 internal) Group ACost for 1 Point 43 P & Installation of Exhaust fan 0.5 HP, sweep size 250 to 450 mm as per size requirement of room/ bathroom /Kitchen etc 44 P & Installation of 25 ltr geyser , five star energy saving having copper tank with 5 year tank warranty and two year element and other wiring warranty. 45 Providing and fixing up to floor five level precast cement concrete solid block in 1:2:4, including hoisting and Setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering, shuttering complete : 46 6 mm cement plaster of mix 1:3 (1 cement: 3 Fine sand) 47 Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS 15622 (thickness to be specified by the manufacture) of approved make in all colours, shade except burgundy, bottle green, black of any size as approved by engineer in charge in skirting, riser of steps and dados over 12mm thick bed of cement mortar 1:3 ( 1cement:3 course sand ) and jointing with grey cement slurry @ 3.3 kg/ sqm including pointing in white cement mixed with pigments of matching shade complete. 48 Applying a coat of water thinnable cement primer of approved brand and manufacturer on wall surface. Water thinnable cement primer. 49 Finishing wall with water proofing cement paint of required shade: New work (Two or more coats @ 3.84 Kg/10 sqm) 50 Structural steel work in single section fixed with or without connecting plate including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 51 Steel work in built up tubular ( round, square or rectangular hollow tubes etc.) trusses etc. including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. : Hot finished welded type tubes. 52 Providing and fixing Sandwich Puf Panels should have been made on the high-pressure foaming machine (Perfect Density Range is 40 ± 2 kg/m³, thickness 120 mm. The top & bottom sheet should have a minimum of 90 gsm galvanaising ,The metal sheet should have a minimum of 20-25 microns of Top Coat & 7 microns of Bottom Coat.,Locking Arrangement of Panels: It should have Tounge & Groove, as well as a Cam Locking system. Both side outer wall with ISI makeGI sheet having thickness not less than 0.60 mm. 53 Providing and fixing plain Multipurpose Cement board ( High Pressure steam cured ) as per IS : 14862, with suitable screws for fibre cement board in ceiling etc. complete 54 Providing and fixing 50 mm thick thermal insulation with Resin Bonded Fibre glass wool conforming to IS:8183. Density 16Kg/cum, 50 mm thick, wrapped in 200G Virgin Polythene bagsplaced over false ceiling and behind plywood to be provided for inside wall insulation and held in position by criss-crossing GI wire. 55 Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Two track two panels sliding window made of (small series) frame 52 x 44 mm &sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 1.75 sqm) 56 Two track two panels sliding window made of (big series) frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension . (Area of window above 1.75 sqm upto 2.50 sqm). 57 Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthened clear float glass 6mm thick, spacer tube 12mm wide, desiccants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.25.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Air gap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/ m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. 58 Providing and Fixing factory made uPVC door frame, made of uPVC extruded sections, of size 65 mm x 55 mm with wall thickness 2.0 mm(± 0.2 mm), corners of the door frame to be mitred cut and jointed with plastic brackets and stainless steel screws, reinforcing hinge side vertical of the frames with PVC profile of Size 28 mm x 30 mm having wall thickness 2 mm (±0.2 mm), including providing & fixing 3 nos of 125 mm long stainless steel hinges to the frame, fixing the frame with jamb with required number & size of anchor dash fasteners, all complete as per manufacturers specification and direction of Engineer-in-charge 59 Providing and fixing 37 mm thick factory made PVC door shutter, styles and rails made of PVC hollow section of size 100 mm x 37 mm with wall thickness 2 mm (± 0.2 mm), with inbuilt bead on one side, styles and rails mitered cut and joint at the corners by means of 2 nos of plastic brackets of size 75 mm x 220 mm at each corner and stainless steel screws, reinforcing the hinge side of style by inserting PVC profile of size 28 mm x 30 mm, with wall thickness 2 mm ( ± 0.2 mm). Lock rail of size 100 mm x 37 mm, wall thickness 2 mm (+ 0.2 mm) will be fixed to the vertical styles. Providing with PVC snapfit beads and panel of size 100 mm x 20 mm, and inserting 2 nos tie bar of 6 mm dia and fastening with nuts and washers complete, all as per manufacturers specification and direction of Engineer-in-charge. 60 Providing wood work in frames of false ceiling, partitions etc sawn and fixed position: Sal wood. (IndianSal wood free from Knots and cracks ) 61 P/F fency curtain rods with clamps and side fency brackets with necessary screws etc complete . C.P. Road 25 mm dia . 62 Providing and fixing in wall lining flat pressed three layer (medium density) particle board or graded wood Pre-laminated one side decorative lamination on other side balancing lamination Grade I, Type II, IS : 12823 marked, including priming coat on unexposed surface, with necessary fixing arrangement and screws etc. complete : 18 mm thick. 63 Providing and fixingdeodar wood beading of size 35x10 mm to ceiling frames with iron screws, plugs and priming coat on unexposed surface etc complete. ( Free from Konts) 64 Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment. 65 Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels,including (a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)- cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including: (b)Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. (C)Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass. (d)Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight (e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge. Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this sub- head. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves) on the external face shall be measured in sqm. up to two decimal places. Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NABL accredited lab or any other accreditation body which operates in accordance with ISO/ IEC 17011 and accredits labs as per ISO/IEC 17025 (1.) Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr (2.)Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range up to 2000 ml. (3.)Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml (4.)Structural Performance Deflection and deformation by static air pressure test(1.5 times design wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm (5.) Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test, Tests to be conducted on site. (6.) Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml. 66 25 mm wooden planking, tongued and grooved in flooring, including fixing with iron screws complete with second class Deodar wood. (Free from Knots and cracks and well-seasoned wood ) 67 Providing and laying Vitrified tiles 600 x 600in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). 68 Providing and fixing 18 mm thick gang saw cut, mirror polished, pre-moulded and pre -polished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing,moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab colour black, Cherry/Ruby red Area of slab over 0.50 sqm 69 Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work 70 Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 71 Carrying out consultancy sevices for topographical survey of land (Working site, complete BOP), preparation of LOP, Soil investigation, structural design and drawings, architectural drawing, detail working drawings vetting of design from IIT or NIT
Disclaimer
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tender Detail
| Website | https://etender.cpwd.gov.in/login.html |
| Quantity | |
| MSME Exemption | No |
| Tender Type | Open Tender |
| Startup Exemption | Click Here |
| Competitive Bidding | NCB |
TENDER INSIGHTS
858
Electric TendersLive
Tell us about your Product / Services,
We will Find Tenders for you