TDR : 56556121
Central Public Works Department

Tender Brief :

Agartala, Tripura

RMO 125 KVA Diesel Generating Sets And Pump Sets In AG Office And 30 KVA Diesel Generating Set And Pump Sets In AG Residential Complex At Agartala During 2026-27.

Published: 18 Jul 2026
Opening: 27 Jul 2026
Closing: 27 Jul 2026
Amount: 14.49 Lakhs
EMD: 28987
Tender Fee: Ref. Documents


Works Electrification Work Actuator Cathodic protection system Cable Tray Impellers
6
Days Left
Tender Summary / Eligibility Criteria
RMO 125 KVA Diesel Generating Sets And Pump Sets In AG Office And 30 KVA Diesel Generating Set And Pump Sets In AG Residential Complex At Agartala During 2026-27.
Documents Download All
96477e67-cf0b-4cd4-b38b-7f95f110bbe1
96477e67-cf0b-4cd4-b38b-7f95f110bbe1.html
DocumentsList
DocumentsList.zip
No Boq
No Corrigendum
Probable Bidders

AI engine predicts probable bidders to help you bid strategically.

MSME Exception
Explore More →
Technical
Tender involves procurement of high capacity electrical equipment including diaphragm coupling of pump & motor with 90kW capacity at 2900 RPM. The project scope includes installation, testing, commissioning and operational handover.
Previous / Similar Result
BRR : 10650067 Routine Operation And Maintenance Of Different Water Pump Sets ( Electric & Diesel ) Installed At Marine Dockyard, Dss Office Complex, Jawahar Colony & Dollygunj Including Maintenance Of Iei To The Residential Buildings At Marine Hill, Jawahar Colony & Maintenance Of Iei & Eei At Dollygunj Under Directorate Of Shipping Services Atport Blair During 2023 - 2024.
Contract Date : Ref. Documents   |   Contract Value : Ref. Documents
BRR : 9528620 Tender For Provision Of Cgsd (Kochi) At Willingdon Island, Kochi; 1 SCHEDULE A Part - I (BUILDING & STRUCTURE WORKS)Details of prepriced schedule is given in tender documents. 2 SCHEDULE A PART-II ( SITE CLEARENCE/DEVELOPMENT & EARTH WORKS) Details of prepriced Schedule is given in tender documents. 3 SCHEDULE A PART-III (INTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents. 4 SCHEDULE A PART-IV (INTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents. 5 SCHEDULE A PART-V (FIRE FIGHTING)Details of prepriced Schedule is given in tender documents. 6 SCHEDULE A PART-VI (ROAD/PATH/ HARD STANDING/CULVERT)Details of prepriced Schedule is given in tender documents. 7 SCHEDULE A PART-VII (EXTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents. 8 SCHEDULE A PART-VIII (EXTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents. 9 SCHEDULE A PART-IX (SEWAGE DISPOSAL) Details of prepriced Schedule is given in tender documents. 10 SCHEDULE A PART-X (AREA DRAINAGE) Details of prepriced Schedule is given in tender documents. 11 SCHEDULE A PART-XI (COMPOUND WALL) Details of prepriced Schedule is given in tender documents. 12 SCHEDULE A PART-XII (ORGANIC WASTE CONVERTER AND SMART ENERGY METER) Details of prepriced Schedule is given in tender documents. 13 SCHEDULE A PART -XIII (MISCELLANIOUS ITEMS) Note:- This schedule is not pre-priced by MES and the rate shall be quoted by the bidder. 14 INTERNAL WATER SUPPLY S & F for 15 mm dia bore CP two way bib cock with CP wall flange (Make : Jaquar Model No. OPP15041PM / Eqvlt in Kohler/Grohe), cast copper alloy, screwed down high pressure with crutch screwed both ends for CPVC pipes or for union and fixed complete all as specified and directed by Engr-in-charge. 15 S & F for 15 mm dia bore CP bib cock with CP wall flange (Make : Jaquar Model No. OPP15037PM / Eqvlt in Kohler/Grohe), cast copper alloy, screwed down high pressure with crutch, screwed both ends for CPVC pipes or for union and fixed complete all as specified and directed by Engr-in-charge. 16 S & F for 20 mm bore concealed Stop cock reqular brass body with spindle extnwith Exposed Part Kit of Concealed Stop Cock with Fitting Sleeve, Operating Lever & Adjustable Wall Flange (Compatible with ALD-083CQT & ALD-089CQT)(Make : Jaquar Model No. ALD 089 CQT/ Eqvlt in Kohler/Grohe), cast copper alloy, screwed down high pressure with crutch , screwed both ends for CPVC pipes or for union and fixed complete all as specified and directed by Engr-in-charge. 17 S & F for 25 mm dia bore concealed Stop cock reqular brass body with spindle extn with Flush Cock & Wall Flange 25mm Ceramic Disc Cartridge) with Plain Knob (Make : Jaquar Model No. ALD 081/ Eqvlt in Kohler/Grohe), cast copper alloy, screwed down high pressure with crutch, screwed both ends for CPVC pipes or for union and fixed complete all as specified and directed by Engr-in-charge. 18 S & F 20mm bore CP angular stop cock with CP wall flange (Make : Jaquar Model No. CQT 23053 / Eqvlt in Kohler/Grohe), cast copper alloy, screwed down, high pressure with crutch, screwed both ends for iron pipe or for union and fixed 19 S & F for 100 mm overhead shower rose round shape single flow (ABS Body chrome plated with gray face plate (Make : Jaquar Model No. 1989 with SHA 479L300S / Eqvlt in Kohler/ ESS ESS) with Shower Arm ø20mm & 300mm Long Round Shape with 90˚ Bend for Wall Mounted Showers with Stainless Steel connected to pipe complete all as specified and directed by Engr-in-charge. 20 COOLING APPLIANCESDesign, Supply, Installation, Testing and Commissioning of Invertor Type Floor Mounted Packaged AC Units including indoor and outdoor unit complete of specified capacities, combination of energy efficient Inverter compressor plus fixed compressors, nominal capacity condensing unit with all standard fittings, safety devices, like HP/LP cutout, single phase preventor, overload relays, R-410A Gas, vibration isolation pads etc. Suitable to work till 50 Deg ambient, Blue Fin Condensor and Corrosion Resistant Body, Wide Voltage Range 360V - 440V, The quoted rate shall include Group controller also asrequired for controlling AC from a single point and timer option for load sharing of AC units complete all as specified and as directed by Engineer - in - charge, of following capacities.Note: Design report shall be submitted before execution of work at site by the contractor to GE for his scruitiny/comments and further submitted to AO for his approval.Make: Blue Star/Daikin/Haeir/Godrej/Voltas/Equivalent. 21 a) 22 TR Inverter Package AC Units 22 b) 16.5 TR Inverter Package AC Unit 23 BLANK 24 BLANK 25 BLANK 26 Supply, Installation and Testing of Refrigerant pipingwith necessary clamping (suction & Discharge) Hard/Soft drawn Copper tube of suitable sizes, with copper elbows, tees, Tubular Nitrile Insulations etc as required complete all as specified and as directed by Engineer - in - charge. 27 S & F Control Cabling B/W Indoor & Outdoor units 28 M & L Refrigerant Gas - R410A 29 Supply, Installation and Testing of Hard PVC drain piping. Drain piping with Tubular Nitrile Rubber Insulation: complete in all respects, well clamped till drain Points complete all as specified and as directed by Engineer - in - charge. For All Units 30 DUCTINGSupply, fabrication, installation, testing of GI rectangular ducts, complete with all fittings such as tee, bends, special off shoots, inspection doors, transformation pieces etc. as required as per IS 655 including suspension and supporting arrangement for plenum, duct etc. required complete all as specified and as directed by Engineer - in - charge. 31 a) Using 0.63 mm (24 Gauge) GI sheet 32 b) Using 0.80 mm (22 Gauge) GI sheet 33 c) Using 1.00 mm (20 Gauge) GI sheet 34 DUCT INSULATION & LININGSupply and Installation of Acoustic Insulation of ducts using 9MM Open Cell Nitrile Rubber, well adhesived, 150 - 180 Kg/cm2 complete all as specified and as directed by Engineer - in - charge. 35 Supply, installation & testing of Thermal Insulation of ducts using 9MM Closed Cell Nitrile Rubber, well adhesived, 40-60 Kg/cm2 complete all as specified and as directed by Engineer - in - charge. 36 S & F Canvas Connection 37 AIR DISTRIBUTION PRODUCTSSupply and Fixing of Powder Coated Aluminium Grills/ Diffusers (Supply/ Return) complete all as specified and as directed by Engineer - in - charge. 38 S & F Collar Dampers 39 Supply and Installation of Fire Dampers complete all as specified and as directed by Engineer - in - charge. 40 Supply, Installation, Testing and Commissioning of Heater Bank Plus Humidistat Arrangement complete all as specified and as directed by Engineer - in - charge. 41 Supply and fixing, testing and commissioning water coolerhaving stainless steel body with inbuild purifier HIMA 7 NHC, dispencing capacity 125 ltr/hr and storage tank capacity 40 ltr normal and 40 cold electric driven (single phase), 230 volt, AC power supply with all connecting accessories complete all as specified and directed. 42 Supply and fixrefrigerator, electric driven (single phase), 220 V,50 HZ, capacity 195 Litres, 3 Star rated direct cool inverter, single door all as specified and directed by the Engineer-in-Charge. 43 Supply and install, testing and commissioning of split type air conditioner 1.5 TR Capacity of invertertechnology 5 star rating with cordless remote control single phase 240 volts complete with all accessories such as indoor and outdoor units and refrigerent tubing of adequete length as required at site indoor mounting plate, duly powder coated fixing with anchor bolts at any height, drain pipe of suitable size brought to ground level from any height, initial filling of refrigerent gas including making round hole on existing wall for taking up refrigerent tubing, drain pipe, cables, etc and making good the disturbed surface by matching with existing adjoining surface complete all as specified and directed (Cooling appliances- qty 4, Air conditioning- qty 10) 44 Supply and fix Voltage stabilizer 3 KVA for automatic operation, single phase naturally air cooled indoor type, wall mounted & designed for input variation between 170 V to 280 V with output voltage stabilized at 230 V with accuracy of ± 2.5% 45 Supply and fix Voltage stabilizer 4 KVA for automatic operation, single phase naturally air cooled indoor type, wall mounted & designed for input variation between 170 V to 280 V with output voltage stabilized at 230 V with accuracy of ± 2.5% (Cooling appliances-qty4, Air conditioning- qty 10) 46 AIR CONDITIONINGSupply and install,Testing & commissioning of split type air conditioner 2 TR capacity of inverter technology 5 star ratingwith cordless remote control, single phase 240 volts complete with all accessories such asindoor and outdoor units and refrigerent tubing of adequete length as required at site, indoor mounting plate, duly powder coated fixing with anchor bolts at any height, drain pipe of suitable size brought to ground level from any height, initial filling of refrigerent gas including making round hole on existing wall for taking up refrigerent tubing, drain pipe, cables etc and making good the surace by matching with adjoining surface complete all as specified and directed. 47 Supply and fix Voltage stabilizer 5 KVA for automatic operation,single phase naturally air cooled indoor type, Wall mounted type & designed for input variation between 170 V to 280 V with output voltage stabilized at230 V with accuracy of ± 2.5% 48 INTERNAL ELECTRIFICATIONS & F LED Mirror light 1 x 5W LUMOS ECCO 1 feet Make: Luker or Equivalent 49 S & F modular MCB DBOx 3 Pin Socket with MCB SP 20 Amp, 240 V including plastic enclosure as per manufacturer instruction fixed on wall surface complete for Air conditioner all as specified and as directed. (Make:-Havells, Model-DHDMCSN0251016 or equivalent) 50 Supply and fix Air circulator of 600 mm sweep AC single Phase. 230V, 1440 RPM complete all as specified and as directed. (Make: Havells model, Turbo Force Wall or equivalent) 51 S & FVertical triple pole & neutral (VTPN), double door, 16-way metallic modular distribution board conforming to IEC 61439-3, suitable for flush / surface mounting with provision for FPMCCB as incomer and TPN/SP MCBs as outgoing, reversible metal door, 200 A copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wiriest & cable ties for cable management, profited masking sheet, etc. having IK 09 & IP 43 protection complete all as specified and directed. 52 S & FVertical triple pole & neutral (VTPN), double door, 4-way metallic modular distribution board conforming to IEC 61439-3, suitable for flush / surface mounting with provision for FPMCCB as incomer and TPN/SP MCBs as outgoing, reversible metal door, 200 A copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wiriest & cable ties for cable management, profited masking sheet, etc. having IK 09 & IP 43 protection complete all as specified and directed. 53 M & L for Flame ProofMCB Distribution board SPN 12 way, with case iron body, powder painted, with 100 Amps rated bus bar etc. including provision of one 32 Amps SPN MCB as incoming and 6 Amps SP MCB -10 Nos as outgoingcomplete all as specified and as directed. 54 M & L for Flame ProofMCB Distribution board SPN 8 way, with case iron body, powder painted, with 200 Amps rated bus bar etc. including provision of one 32 Amps SPN MCB as incoming and 6 Amps SP MCB- 6 Nos as outgoingcomplete all as specified and as directed. 55 Supply and fix Engage light with Green & Red LED complete all as specified and as directed 56 Supply and fix of CS mounted high intensity LED search light, long range, manually swivel in all direction, 250 W, minimum range 700 meters, Single, LED Efficiency> 140 lm/w, PF> 0.95, CCT 5500K - 6500K, Optical grade PMMA/PC lens/reflector efficiency>95%, multiple circuit to avoid complete run down, anti UV, narrow beam 5 degree, die cast LM6 body with air fins, powder coated, constant current, an average lux at 10 meter - 8000 lux with circle of approx 600 mm, working temp: -20 to +60 degree C, input Volt 100-300 VAC, 50 Hz, PF >0.95, IP-66, confirming to LM79/ LM80 and type tested as per IS: 10322/ IS: 13383, BIS approved and Govt lab tested for lux intensity. The search light is completed with manual revolving CS stand D20cm x H15cm (min.) with 3 nos. foundation holes for mounting of searchlight on watchtower structure, manual rotation of light on horizontally 360 degree with 45 degree tiltable with provision of both instant locking arrangement at desired position. Model No. CS-LRFLL-25PC25 of KALIN make or equivalent 57 Supply, install, testing and commisisong of outdoor floor/wall mounted thermoplastic polycarbonatefeeder pillar panel, Enystar EmptyEnclosures, IP-65, weatherproof, corrosion free, Halogen and Silicon Free, Frame retardant with Opaque Lid Size-[276 x 546 x 186]mm and Transparent Hinged Lid, completed all as specified and directed. 58 M & L for TV socket module metal flushed including flushed Box cover plate Box for 2 way module complete all as specified. 59 M & L for telephone jack with module metal flushed including flushed Box cover plate Box for 2 way module complete all as specified. 60 Supply and lay coaxial cable for TV Cabledrawn through conduit 61 S & F flame proof exhaust fan 300 mm sweep, single phase, 1440 RPM complete all as specified and as directed. 62 FIRE FIGHTINGSupply and fix Foot Valve conforming to IS 4038, 100 mmdia. 63 Supply and fix Foot Valve conforming to IS 4038, 150 mmdia. 64 Supply and fix Cast Iron Air Valves with single air Outlets, conforming to IS 14845 of size 100 mm dia bore and fixing up in Cast Iron Water supply mains of size 100 mm dia. 65 S & F sprinkler flexible drop pipe 1 mtr long. 66 S & F sprinkler rossette 25 mm dia. 67 Supply and installation, testing and commissioning of Analog Addressable type Active Loop Repeater (Loop power/external power) Fire terminal with inbuit turbo isolator, Backlit LCD Display 6x40 characters display, having Controls For Reset, Mute, Accept, Silence alarms and Self Test, with programmable free keys and Duly Approved byEN54/LPCB/VDS/FM Make: SIEMENS/NOTIFIER/BOSCH 68 M & L for Low smoke Zero helogen flame retardent fire alarm cable2 core, 1.5 mm² copper conductor confirming to BS7629-I, BS6387 & rated for 500 v grade having plaine sraded copper coductutor with priming insulation of glass mica fire resistance tape & secondery insulation of high performancesilicon rubber with electrostatic screen of aluminium fire barrier Type LT53 outer sheath confirming to BS 7655, red in colour drawn through & including concealed steel conduit including laying,fixing,connecting complete all as specified and directed. 69 Staircase signage down of make bajaj cat part no. 111499 model no. DSDWBB 3W double side display for staircase downwards (with 2 hours built in battery backup) complete all as specified and directed at site complete all as specified and directed. 70 S & F wall mounted LED emergency Exit signage luminaire Lit up using regular mains supply comes with a unique rechargeable Ni-Cd battery capable of emergency back up upto 05 hours(Cat No. 220211 Make Bajaj or equivalent to CG/Havells. 71 Supply, Installation, test and Commissioning CPRI APPROVED factoryfabricated, indoor type, LT panel board , made out of 2 mm thick CRCA Sheetsingle door withboth side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embeddedwith 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete withinternal connection with suitable size of cable, cable lugs and cable glandsPCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Testing after Installation includingcomplete all as specified and comprising of the following:- Make of MCCB/MCB -MDS/LEGRAND/L&T/HEGGER (Main Fire Fighting Panel)INCOMING(i) MCCB 4 Pole 400 amp 50 Hz, 415 V with rupturing capacity 35 KA with microprocessor based release - 01 No.(ii) Voltmeter Digital type 0-500 Volts range flush type with selector switch- 01 No.(iii) Aluminium Bus bar TPN - 600 amps- 1setOUTGOING(i) MCCB 3 Pole 200 amp 50 Hz, 415 V with rupturing capacity 35 KA with microprocessor based release- 02 No.(iii) MCB TPN 32 Amp - 03 Nos.(iv) 80 HP S/D soft STARTER- 02 Nos.(v) DOL STARTER 7.5 HP- 02 Nos.(vi) Motor Protection Relay32-88 amps- 2 nos. (vii) Motor Protection Relay2- 5.5 amps- 2 nos. (viii) On/Off/Trip Indication Lamps, 220 V AC- 6 nos.(ix) Start/Stop Push Button, 4 Nos. (x) Phase indicating lamps RYB for incoming and each outgoing connection.(xi) Digital type Ammeter 0- 150 amps with selector switch and CT coils of suitable capacity for incoming and each outgoing connection- 1 no. 72 M & L for coating and wrapping of under ground steel pipe buried in soil shall have protection against corrosion as per IS-10221.The coating and wrapping shall be carried out in systamatic manner to get uniform thickness of coating as per IS specification 73 Supply, Installation, test and Commissioning CPRI APPROVED factoryfabricated, Indoor type, LT panel board, made out of 2 mm thick CRCA Sheetsingle door withboth side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embeddedwith 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete withinternal connection with suitable size of cable, cable lugs and cable glandsPCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Testing after Installation includingcomplete all as specified and & directedby Engr-in-charge comprising of the following :– ( Booster terrace pump panel)INCOMING:-(a) INCOMING MCCB 40 A 25 KA, 4 POLE- 01 No.(b) Busbar TPN of size 100 apms - 1 setOUTGOINGS:-(a) MCB 3 POLE TPN 32 Amps,10 KA-2 Nos.(b)DOL Starter for 7.5 HP Pump set-1 Nos.(c) Ammeter Class-1, digital panel mounting type 96mmx96mm L & T cat no WDS301FCA00 including CT 50X5 Amps 3 nos & selector switch-4 nos(d) Voltmeter Class- 1, digital panel mounting type 96mmx96mm L&T CAT NO.WDS301FEV00 & selector switch - 1 no.(e) LED TYPE indicator lamp 1 set (set of three for R,Y,B)(f) Mini protecrionRelay 4-11 amp - 1 nos. 74 Fire Extinguisher mechanical Foam type trolly mouted of 9 Liters capacity. Ceasefire 9 litrs fire Extinguisher AFFF Foam type, External Cartridge type, Pressure Guage Gross weight 14.6 Kg, empty weight5.6 Kg, Can height 611 MM, Diameter 175 MM, Discharge time less than 60 Secs controllable discharge mechanism, Minimum 6 Mtrs, Applicable on Class A, B, can construction deep down & CO2 Mig welded Valve Construction: Forging & Machining, Internal coating of can: Epoxy powder coating, External coating of can: Epoxy poyster powder coating sheet metal thickness 2.0MM,1 year warranty. Make Cease Fire Or Equivalent. (pol store) 75 Supply, Installation,Testing & commissioning of Carbon Dioxide (Co2) type fire extinguisher of 4.5 Kg confirm to IS: 15683, with ISI marked/TAC approved fitted with required accessories including wall suspension brackets. 76 Supply, Installation,Testing & commissioning ofDRY CHEMICAL POWDER (ABC) stored pressure type fire extinguisher of 6 Kg confirm to IS: 15683, with ISI marked/TAC approved fitted with required accessories including wall suspension brackets. 77 Supply and fixing single unit flame type detectors (Triple IR infrared flame detectors) Addressable type Flame detectors with UV/IR detection capacity (add up cost of module to be a complete set, the type of module shall be relaying type module) complete all as specified and directed 78 Supply and fixing,Test and Drain valve 65/50mm, forged brass body, brass chrome plated ball, 304SS stem with Polycarbonate sight glass, indicator and handle made of steel complete all as specified and directed 79 SPECIAL EQUIPMENTS FOR STORESDesign, manufacture, Supply, installation, testing and commissioning of Automated Storage and Retrieval System with storage racks, pallets, stacking crane, computer hardware with compatible inventory software as a turnkey solution complete all as specified and directed. Automated Storage and Retrieval System shall consist of computer controlled & PLC stacker crane driven system for automatically placing & retrieving materials from defined storage locations. The crane shall be capable of lifiting, stacking and retriveing the pallet loads weight upto 1125 Kg (max) complete all as specified and directed by the Engineer-in-Charge. Technical data for design of heavy duty ASRS:-(a) Dimensions:-Height:10 Mtrs for racking system which shall be designed and constructed to store the required no. and size of pallets.(b)Storage capacity:-Pallet Size: 1300 (W) x 1200(D) x 1250 (H) in mmPallet Nos.: 480Pallet load capacity: 1125 KgTotal capacity: 540 Tons(c) Stacker Crane: Double mast automated stacker crane for handling Pallet, size 1300mm(W) x 1200mm (D) x 1250mm (H) and pay load (including Pallet self weight) of 1125 Kg max. The stacker crane shall be capable of picking up the pallet from in-feed conveyor or loading station and stacking it into empty slots of racking system. Similarly, it shall also be capable of retrieving the palltet from racking system and putting it on the same conveyor or unloading station. Stacker crane will be mounted on rails at the bottom to traverse the length of the storage system. Top rails mounted on the racking system shall also support it. PMDC motars should be used with required counter weight for better efficiency of verticle travel.General technical parameters of stacker crane:Technical parameters/Type- Double Mast(i) Operation mode (Networking)- On-line automatic / Single automatic (Ground/Boarding) /Manual operation (Boarding) / Maintenance (ii) Communication Means- Wireless 80 (iii) Power supply mode- 380 to 415 V, 50 Hz, three phase five wire (iv) Addressing mode- Horizontal and verticle operation: photo electrical sensor + bar code scanners(v) Positioning / Reduction accuracy (mm) level- lifting ± 3 - 5, Fork : ± 3(vi) Fork unit- 1 Double deep fork(vii) Load unit- MS Pallet (viii) Total Height- 10 Mtr(ix) The normal lifting speed (m/min) - 10 MPM(x) The normal running speed (m/min) - 65 MPM(xi) Rated load- 1125 Kg(xii) Receipt equipment fixed platform/conveyor/lifting /platform(electric/manual)- Conveyor(d) Pallets: to stack and retrieve the pallet weighing up to loaded pallet weight 1125 Kg at height up to the last loading level in the racking system. It should have retrieval mechanism to enable stacking & retrieval of pallet from either side of the rack and also to pick up the load directly from the loading station.Pallet Details:-(i) Dimensions - 1300mm(W) x 1200mm(D)(ii) Pallet height- 1250 mm(e) Racking system:- Two single aisle having two row racking system each with 05 verticle levels for storage of material. Racking for double deep type storage of 480 Pallet of size 1300mm(W) x 1200mm (D) x 1250mm (H). Loaded pallet weight: Pay load with pallet 1125 Kg max. System details:-Working aisle -01 Nos. (Double deep)Store rack -24 Nos./RowTotal rack in 1 aisle-24 (Left) + 24 (Right)= 48 Nos.No. of level- 5 Nos/RackTotal Pallet-48 x 5 x 2 = 480 Nos.Load capacity- 1125 Kg/LevelDouble mast stacker crane-01 No. 81 (f)Aisle Equipment:-This will consist of electrical as well mechanical aisle equipments and willl be designed as per the pallet requirement. The mechanical Aisle equipment of bottom rail shall consist of I Beam and will be provided with adjustable calmps for holding the rail in position to ensure proper alignment. Top rail shall be mounted on the racking. The electrical aisle equipment shall consist of power rail (fully enclosed bus bar having 7 pole system), which is mounted on the racking system below the first loading level.(g) Details of rack members:-The racking system shall consist of cold-rolled steel sections as per manufacturers design to accommodate and store pallets and connected systems.(h) Loading- unloading station/ Conveyor(i) Pallet Load 1125 Kg max.(ii) Bearing- SKF Equivalent make(iii) Motor- Seimens/Sew Euro Drive/Nord Sew/ Bonfiglioli or equivalent(iv) Gear Box- Bonfiglioli Make or equivalent(v) V.F.D.- Yashkawa make or equivalent(j) All steel surface shall be powder coated finish with 8 tank treatment process.(k) Maintenence: The annual maintenence of complete ASRS system during the defect liability period of two years shall be included in the rate quoted for the system and the AMC contract duly signed with the manufacturer of the ASR system shall be submitted at the time of handling over the system. The AMC shall include all spares and consumables etc required during the period of two years and nothing extra shall be paid on this accountNote- 1)Mechanical safety provision (i) End of aisle shock absorbers / bumpers for stacker crane.(ii) End of travel buffer for the lifting crane.(iii) Safety catches on lifting carriage.(iv) Anti-tilt mechanism for the stacker crane. An additional antifall device must be provided for the lifting carriage. In the event of electromagnetic break motor failure or malfunction, this device should automatically engage to safely hold the carriage and prevent any freefall, thereby avoid accidents due to emergency brake failure.(v) Continuous rail cleaning brush for floor rail.(vi) Adjustable rail clamp to ensure alignment. 82 (vii) Resilient rubber pads on adjustable clamps for vibration dampening.(viii) Profile check on lifting carriage to check all three dimensions (width, depth & height) of the pallet. Note - 2 Electrical safety provision (i) There shall be Emergency stop push button at all panels and stations.(ii) Optical light beam amd mechanical safety sensor to stop the operation in case of improper storage.(iii) Back up circuitry for proper system operation.(iv) An electromagnetic brake shall be used to avoid the slippage of the hoist.(v) Stopper shall be provided for the maintenance door.(vi) Load cells shall be provided for the over weight of tray.(vii) Automatic door shall be provided for operator safety while machine in operating condition.Note - 3 Physical safety provision (i) The ASR system shall comprise of safety fences having grid size of max. 40 x 40mm & wire dia should be of min. 3 mm. Height of the fencing should be minimum 2.0 meter.(ii) One No. of electromagnetic aisle access door shall be provided. It should cover the complete length of the system on one side.(iii) A manual locking system to restrict the movement of unauthorised personnel shall be provided.NOTE: 1) Design report shall be submitted before execution of Work at site by the contractor toGE for his scrutiny / comments and futher submitted to AO for obtaining approval. Item No. 13.070 below shall be compatible with this item/ system and both should be integrated. Changes in make of different components of ASR system and minor changes in different parameters are permitted with approval of Accepting Officer as per recommendation of ASR system manufacturerprovidedthe end objective of the system is complied.2) The ASR system is to be installed in Bulk store house complex. Necessary civil works for installation of the ASRS required in the building is included in the scope of this item. Neccessary arrangements for integration of system with flooring and overhead trussess of the building shall be done at appropriate stage and shall be included in the rates quoted3) The PLC program backup for the ASRS and Advanced Inventory Management System shall be provided in an editable format. The WMS program shall be provided along with its source code to enable the user to perform maintenance, modifications and future upgrades as part of the project acceptanceMake of ASR system:Armstrong Ltd/ Godrej Koerber/ Kardex India storage solutions Pvt Ltd/ Daifuku India Pvt Ltd/ Addverb technologies Ltd/ Craftsman Automation Ltd/ Tech-mark 83 Supply, installation, testing and commissioning of Advanced Inventory Management System with compatibile computer hardware and integrated inventory and weight management system with PLC based software complete all as specified and directed by the Engineer-in-Charge. Technical specification of the system(i) System Height(Min) : 6400 (±100) mm(ii) System Width(Min) : 3150 (±100) mm(iii) System Depth(Min) : 2300 (±100) mm(iv) System Base(Min) : 7.24 Sq.Mtr(v) Tray Int. Size(Min): 300 (H) x 2450(W) x 500 (D) in mm(vi) Tray dead weight(Min) - 57 Kg (Approx.)(vii) Per tray weight capacity - 300 Kg(Min)Technical specification of the system:-(viii) Tray Quantity : 32 Nos.(ix) Usable net load - 9.6 ton(Min)(x) Storage surface area per system - 39.2 sq mtr(Min)(xi) Door - Automatic, (xii)Power supply - 440V, 50/60 Hz, 3 Phase(xiii) Motor 3 Phase 1440 RPM - Seimens make or equivalent(xiv) Chain - Diamond makeor equivalent, (xv)Bearing - SKF/NTN make or equivalent(xvi) External cladding - Epoxy powder coatedSafety Features:1. Photo curtain at access port, 2. Motor Protection relays, 3. Limit switch at door, 4. Single phase preventer,5. Switch mode power supply, 6. 15 Min battery backup for PLC, 7. Noise less than 60db, 8. Emergency stop various safety alertsNote: 1) The system and software provided under this item shall be of same make as for item 13.066 to 13.069 or a compatible system and software as recommended by the chosen manufacturer of ASR system. This system shall be integrated with ASR system.2) Comprehensive maintenance of the system during two years of defect liability period shall be a part of this item and rates shall be quoted accordingly. Comprehensive maintenance shall include all spares including software update. The ASR and advanced management system shall be operated by single warehouse management system.3) The PLC program backup for the ASRS and Advanced Inventory Management System shall be provided in an editable format. The WMS program shall be provided along with its source code to enable the user to perform maintenance, modifications and future upgrades as part of the project acceptance 84 Supply, installation and testing of Car Traffic Boom Barrier 6 mtr suitable to working on power supply 230 Volt, 50 Hz, 24V DC electric motor, adjustable with CAMS, operating ambient temperature from -20 to +55 Degree Celsius, uses cycle 2000/Day, air cooling, type of beam is rectangular with skirt, effective torque 280-290 Nm open/close time 2 to 4 Sec complete all as specified and as directed by Engineer-in- charge.Make: FAAC/Parkilo/Skidata/BFT 85 EXTERNAL WATER SUPPLYSupply and fix Foot valve conforming to IS, 100 mm dia complete all as specified and directed. 86 Supply and fix Cast iron air release valve with 100 mm bore and two outlets as per IS:14845 complete all as specified and directed. 87 Supply, installing, testing and commissioning of electrically driven horizontal Centrifugal Pump set 9.0 LPS at 50 Meter Head as per specification, motor TEFC type, 2880 rpm, 415 V, 50 Hz, 3 phase, class F insulation, IP 55 protection, starting on suitable Star Delta starter. The pump shall be horizontal, end suction, top discharge. The pump shall have cast iron casing, cast iron/bronze impeller (as per manufacturer), carbon steel shaft with common base frame (fabricated mild steel channel frame or cast iron type) placed on RCC (1:2:4) including foundation, bolts, nuts etc. complete with antivibrator pad as required capable of discharging not less than 550 LPM at 45 mtr head inclusive of suitable rated three phase starter as recommended by the manufacturer, PVC insulated copper cable connection from starter to the motor terminals all as specified and directed by the Engineer-in-charge.(01 No. Working + 01 No Stand By)Make:- Kirloskar Brothers/Crompton or equivalent. 88 Supply, install, test and commissioning of LT Panel, indoor type, powder coated, 2.0 mm thick CRCA Sheet, CPRI approved having, IP 43, MS angle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with Horizontal copper bus bar for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 2.0 mm thick CRCA Sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables. Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, track resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. andcomprising as under: LT Panel for Pump House. The LT Panel comprising of the following:- 89 Incoming:-MCCB, thermal magnetic release, 4 pole, 415 Volts, 100 Amps, breaking capacity 36 KA- 01 No. Ics =100% IcuMetering Unit:- (a) R Y B Indications (LED Type)- 01 sets(b) Digital Multi function meter - 01 No.(c) CTs - 100/5A, CL-1, 15 VA - 01 set(d) Horizontal Aluminium busbar for 3 phase, 440 volts, 50Hz, 4 wire system of rating 350 Amps for phase and 350 amp for the neutral barOutgoing:-(a) MCB, TPN 40 Amp, 415 Volt, C Curve - 03 Nos.(b) Star Delta starter 12.5 HP, 3 Phase, 415 Volt- 02 Nos.(c) Digital ammeter - 2nos.(d) Single Phase Preventer - 2 nos. 90 M & L Valve chamber of internal size 0.90m X 0.90m X 0.90m (internal dimensions) including excavation of earth work in any type of soil, 150mm thick PCC in 1:4:8 type D2 foundation, brick work in CM 1:6, 15 mm thick rendering in CM 1:4 to internal surfaces and external surfaces upto 150mm depth below GL, PCC 1:3:6 type C1 as in coping, cover with two Nos. of hinges and one No. handle made out of MS round bar 10mm dia with necessary locking arrangement including painting to the steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer complete all as shown on drg and as specified. Note:- The quoted rate shall include all earthwork and connected items. 91 M & L Earthing complete with Galvanized steel earth plate electrode of size 600mmX600mm, 6.00 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below the normal ground level with top edge of the plate not less than 1.5m below normal GL and connected to galvanized iron strip of size 32 x 6 mm size by means of bolts, nuts, check nuts and washers of galvanized iron steel all as shown in Electrical Plate No. 3 connecting to earthing test point, including necessary earth work in any type of soil, PCC earth chamber made in PCC 1:3:6 type C1 (using 20mm graded aggregate), common salt, charcoal, CI funnel, earth pit cover in RCC 1:2:4 type B1 (using 20mm graded aggregates), with 8mm CTD bars @ 100mm c/c in both ways, including necessary form work complete including necessary test on completion all as specified and as directed. 92 EXTERNAL ELECTRIFICATIONM & L for HT/LT MS cable route indicator, engraved the description on the disc not less than 6 dia welded with 40x6xmm MS strip of approx length 90 cm duly painted on the steel parts as per colour code and provision of PCC 1:4:8 type D-2 using 40 mm grade stone aggregate of not less than 0.05 cum in each at base under the ground including necessary earth work and formwork complete all as specified and directed.Note: HT route indicator shall be painted as under:-(i) For HT 11 KV cables - “BROWN”(ii) For LT cables - “BLUE” 93 Supply and fix compact air insulated bus bar trunking system with copper busbar 1600 Amps, 50 KA breaking capacity, IP54 protection, bus duct 1600 A, 415 Volt, capacity sandwich type, Set RYBN complete with accessories such as flange ends, vertical bends, supporting brackets etc from transformer to LT panel board complete all as specified and directed. 94 Supply, install, testing and commissioning of Distribution transformer step-down Level 2 (Previously EE Level 3 before Amendment No 4 to IS 1180), 11KV / 0.433KV, Three Phase complying withIS: 1180/IEC-76(Part-1) 2014 with latest amendments, indoortype double copper wound suitable for 50 Hz system of capacity 800 KVA, oil immersed naturally cooled delta connected on HT side and Star connected on LT side, Vector Group Dyn11, provided with OFF load tap changer to vary secondary voltage from -7.5% to + 7.5 % in step of 2.5 %.Losses should be confined to the limits specified as follows: maximum allowable losses atfull load (100 %) & Half Load (50 %) shall not be exceeded 5838 watts & 2147 Wattsrespectively as per GRlHA RATING, Percentage Impedance: 4.5%. Losses and Impedance are subjected to tolerance as specified in IS 1180. The transformers should be supplied with first filling of oil confirming to IS 335. The transformer should have both side cable end box with neutral brought out complete all as directed by Engineer - in -Charge, and installation of transformer shall be carried out as per IS-10028and comprising with the following standard fittings/Technical specifications:-(a) Lifting lug for transformer and tank.(b) Earthing terminal rating and diagram plate.(c) Air release device.(d) Oil filling inlet pipe with plug.(e) Drain outlet pipe with brass gate valve.(f) Conservator tank with oil level indicator(g) Silica jel breather(j) First fill of oil upto level including conservator tank with fresh new oil conforming to IS335.(k) Type of connection Delta/Star(l) Type of cooling: Oil and Natural Air.(m) Vector group: DYN 11.(n) Temperature rise over an ambient of 50 °C maximum.(o) Cable end box on both side for HT/LT cables of suitable size.(p) Provision of thermometer with pocket.(q) Provision of oil and winding temperature gauge. 95 Supply, install, test and commissioning of LT Panel, Indoor type, powder coated, 2.00 mm thick CRCA Sheet, CPRI approved having, IP 43, MSangle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply,bus bar chamber with Horizontal copper bus bar for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air.The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 1.6 mm thick CRCA Sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables. Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, track resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. andcomprising as under: The LT Panel comprising of the following:- Main LT PanelHorizontal copper busbar for 3 phase, 440 volts, 50 Hz, 4 wire system of rating 1600 Amps for phases and 1600 Amps for Neutral. 96 Incoming:-Incomer:-ACB 4 Pole, 415 V, 50 KA with Thermal Magnetic Release (Manual Draw out type) of capacity 1250 AmpMetering Unit:- (a) R Y B Indications (LED Type)- 1 sets(b) Digital Multi function meter - 01 No.(c) CTs - 1600/5A, CL-1,15 VA - 1 setOutgoing:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 630 Amps, Ics =100% Icu, breaking capacity 35 KA, Ics =100% Icu- 02 No. (For DG AMF Panel & Spare)(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 400 Amps, Ics =100% Icu breaking capacity 36 KA- 02 No. (for APFC Panel & FPB 2 Near bulk Store) (c) MCCB, thermal magnetic release, 4 pole, 415 Volts, 320/315 Amps, Ics =100% Icu breaking capacity 36 KA- 01 No. (for FPB 1 Near Adm Block) (d) MCCB, thermal magnetic release, 4 pole, 415 Volts, 200 Amps, Ics =100% Icu breaking capacity 36 KA- 01 No. (for Existing Load)(e) MCCB, thermal magnetic release, 4 pole, 415 Volts,125 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for FPB 3 Near Auction Disposal Store)(f) MCCB, thermal magnetic release, 4 pole, 415 Volts, 32 Amps, Ics =100% Icu breaking capacity 25 KA- 03 No. (for MT Complex, Watch tower no 2, Guard room)(g) Digital Ammeter with suitable CT for each outgoing 97 Supply, install, test and commissioning of LT Panel, outdoor type, powder coated, 3.00 mm thick CRCA sheet, CPRI approved having, IP 54, MS angle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply,bus bar chamber with Horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 2 mm thick CRCA sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables. Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, crack resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. Feeder Panel No.1 (Near Admn bldg) 98 Horizontal Aluminium busbar for 3 phase, 440 volts, 50Hz, 4 wire system of rating 600 Amps for phases and 600 Amps for Neutral.Incoming:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 400 Amps, breaking capacity 36 KA - 01 No. Ics =100% IcuMetering Unit:- (a) R Y B Indications (LED Type) - 1 sets(b) Digital Multi function meter - 01 No.(c) CTs - 600/5A, CL-1,15 VA - 1 setOutgoing:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 200 Amps, Ics =100% Icu breaking capacity 36 KA- 02 No. (for 2nd floor & spare)(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 160 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for 1st floor)(c) MCCB, thermal magnetic release, 4 pole, 415 Volts, 63 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for G floor)( d) Digital Ammeter with suitable CT for each outgoing 99 Supply, install, test and commissioning of LT Panel, outdoor type, powder coated, 3.00 mm thick CRCA sheet, CPRI approved having, IP 54, MSangle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply,bus bar chamber with Horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air.The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 2 mm thick CRCA sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables.Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, crack resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. Feeder Panel No.2 (Near Bulk Store) Horizontal Aluminium busbar for 3 phase,440 volts, 50Hz, 4 wire system of rating 600 Amps for phases and 600 Amps for Neutral. 100 Incoming:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 400 Amps, breaking capacity 36 KA - 01 No. Ics =100% IcuMetering Unit:- (a) R Y B Indications (LED Type)- 1 sets(b) Digital Multi function meter - 01 No.(c) CTs - 600/5A, CL-1,15 VA - 1 setOutgoing:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 200 Amps, Ics =100% Icu breaking capacity 36 KA- 02 No. (for Equipment Load & spare)(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 125 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for Bulk Store)(c) MCCB, thermal magnetic release, 4 pole, 415 Volts, 32 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for Watch Tower No. 1)( d) Digital Ammeter with suitable CT for each outgoing 101 Supply, install, test and commissioning of LT Panel, outdoor type, powder coated, 3.00 mm thick CRCA sheet, CPRI approved having, IP 54, MSangle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply,bus bar chamber with Horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 2 mm thick CRCA sheet, duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables.Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, crack resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. Feeder Panel No.3 (Near Auction Disposal Store) 102 Horizontal Aluminium busbar for 3 phase, 440 volts, 50Hz, 4 wire system of rating 200 Amps for phases and 200 Amps for Neutral.Incoming:-(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 125 Amps, breaking capacity 25 KA- 01 No. Ics =100% IcuMetering Unit:- (a) R Y B Indications (LED Type) - 1 sets(b) Digital Multi function meter - 01 No.(c) CTs - 200/5A, CL-1,15 VA - 01 setOutgoing:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 100 Amps, Ics =100% Icu breaking capacity 25 KA- 02 No. (for Store Dispatch Complex & Spare)(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 32 Amps, Ics =100% Icu breaking capacity 25 KA- 03 No. (for Pol store, Auction disposal store, Covered Hard Standing)(c) Digital Ammeter with suitable CT for each outgoing 103 Supply and fixing poly carbonate street light junction boxes IP 66/67 Weather proof suitable for outdoor installation having minimumsize255 x 355 x 122 including suitableCable connecting Terminals, Cable lugs, including provn of one No. MCB SP 6 Amps for operating the street light fittings, Suitable Cable Glands as per site requirement, all as directed by the Engineer-in-Charge. 104 S & F Street light bracket made out of GI tubing 32/40 mm dia, light grade of length1.2 mtr long bend to shape suitable for security light fitting with necessary MS clamp-02 Nos with one coat of anti corrosive primer and two coats of aluminium paint including nut, bolt, washers and 3 core FRLSinsulated sheathed, multistranded copper conductor of size 1.5 sqmm for phase and neutral and 1.5 sq mm for earthing drawn throughthe poles for connection from junction box to light fitting complete etc all as specified.Note: Phase should be Red/Yellow/Blue, neutral should be black and earthing wire should be green in colour. Two runs of cable for phase and neutral and one run of cable for earth will be measured and paid as one unit length. 105 Supply and fixing of LED flood light, 200W, watt 230 V, AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp and made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP protection incl system efficiency >110/120LPW 10KV SPD included Energy saving, environmental friendly and general purpose lighting complete all as specified and directed Engineer-in-Charge. Make : Make : Crompton/Philips/Wipro/Bajaj 106 Supply and fix High Mast Panel outdoor type, suitable to take load up to 6 KW, Conforms to IS/IEC 60947-4-1, Provided with Protection Degree IP 54, Extended wide band (150 Vac - 300 Vac) coil, FRLS (Fire retardant low smoke) Internal wiring, In-built Short-Circuit Protection, Class H Insulation, 3 Phase 415 Volts AC with the following accessories:Phase : 3 Phase, 415 VoltsMax Load Capacity : 6 KWTimer type: AstronomicalContactor Rating : 32 A TPMCB Rating : 63 A TPNMake : Crompton/ Philips/Wipro 107 Supply and laying DWC (Double wall Corrugated) duct pipe outer dia 63 mm and inner dia 50 mmconforming IS 16205 (Part 24 ) for protection ofelectric cable complete all as specified and directed. ( for 10 sqmm St light cable & 16 Sqmm cable) 108 AVIATION OBSTRUCTION LIGHTSupply and fix aviation obstruction light integral aviation light comprising of aluminium housing with polycarbonate enclosure, 240 volt with timer switch and one No.10 A, MCB, SPN 230 V with fixed enclosure complete all as specified and directed by Engineer-in-charge.Make:- Bajaj cat No BGAV 302 LED or equivalent in Philips/Crompton/Surya 109 INCINERATORSupply, fixing and testing and commissioning of Solid waste Electric Incinerator, single chamber type having a combustion chamber supported with electric coil for generating sufficient heat to burn 100Kg/hr solid waste, retains and re-burns the exhaust gases for minimum of 2 seconds at 850°C, Stainless steel stack for longevity, fitted with a Velocity Cowl as standard, Chamber designed for maximum air flow and circulation which in turn improves efficiency and total burn time, easy to open and close loading door, designed to increase operator safety, steel cladding to reduce risk of infection and increase longevity of system with working temperature not less 450 degree Celsius mounted on foundation as recommended by OEM including electrical control panel with suitable size MCCB, relays & contactor recommended by OEM complete all as complete all as specified and directed.Note:(a) The electrical works including electrical LT panel, internal wiring of the LT panel, suitable size copper wires from panel to Solid waste Electric Incinerator as recommended by OEM to operate the Solid waste Electric Incinerator of capacity 100 Kg/Hr to make Solid waste Electric Incinerator operational is deemed to be included in the rate quoted. (b) All Electrical works shall be carried out as per relevant BIS/lS equivalent standard norms only and also in accordance with the latest edition of the Indian Electricity Act / rules formed there under and as amended from time to time.(c) Any other works (mechanical, electrical & Civil) connected to installation, testing & functional requirement of Solid waste Electric Incinerator of capacity 100 Kg/Hr all as mentioned above and which is not mentioned or included in this Schedule but required at site necessary shall be carried out by the contractor and quoted rate shall deemed to included for the same.(d) Foundation/Plinth/Base: shall be provided as per manufactures recommendations, however minimum 0.5m space should be available all around the Solid waste Electric Incinerator and height of plinth shall not be less than 0.5 MMake: Precitech thermal Pvt. Ltd., Rram Buisiness corp, Alfa therm Ltd., Thermax Ltd, Kanti Industries, Fortec 110 Supply & fixing MCCB, thermal magnetic release, 4 pole, 415 Volts, 200 Amps, breaking capacity 36 KA- 01 No.Ics =100% Icu with Sheet metal enclosures fixed properly at directed location and connecting/testing complete all as directed. 111 ELECTRIC SIRENSupply and fixing Sirens Electronic type Horizontal Double Mounting Three Phase 400/440V, 2800 RPM 50 C/s Flame Proof, audible range 3.5 Km, 2 HP, continuous normal operation for at least 50 minutes with on/off system complete all as specified and directed. 112 Supply and fix advance Sirens controller Electronic type suitable to operate on 3 phase, 415 volt AC 50 Hzcomplete all as specified and directed. 113 Supply & fixing MCCB, thermal magnetic release, 4 pole, 415 Volts, 63 Amps, breaking capacity 25 KA- 01 No.Ics =100% Icu with Sheet metal enclosures fixed properly at directed location and connecting/testing complete all as directed. 114 SOLAR POWER PLANTDesign, supply, installation testing and commissioning of roof top solar photovoltaic power plant (ON-GRID) on roof top of existing bldg of capacity 150 KWp, power evacuation at 415 Volt 3 phase system all as per guidelines/norms issued by MNRE & Indian Metrological Deptt approved Solar Radiation Data viz Direct Normal Irradiance, Global Horizontal radiance etc complete comprising with the following Solar Photo Voltaic Plant.(a) Design, supply, installation, testing and commissioning of Solar PV Modules capable of generating 150 KWp (AC) electricity at 415 Volt 3 phase system. These Solar PV Modules of 540 watt PERC with a modular efficiency of 17-19.84% as per IEC and MNRE standard or as per approved design parameters with Poly/Multi Crystalline Silicon Solar cells of minimum wattage of 540 watt with minimum 144 cells & efficiency not less than 17 -19.84%, conforming to IEC 61215, IEC 61730, IEC 61701. Solar PV Module should be of approved Indian Brand only and Qualify under the Domestic Content requirement (DCR) norms of NVVN/SECI and testing requirement fixed by MNRE. The PV modules shall be warranted for a period of minimum 25 years, Solar PV modules used in system shall be warranted for their output peak watt capacity, which should not be less than 90% at the end of Ten years and 80% at the end of Twenty Five years. Each Solar PV Module must use RF identification tag. The following information must be mentioned in the RFID used in each module:Name of manufacture of PV module, Name of manufacturer of Solar cell, Month & year of manufacturer (for solar cell and module), Country of origin (lt is mandatory to use cells and modules manufactured in India). I-V curve of the module, Wattage, LM, V-M, & FF for the module, Unique Serial No & Model No of the module, Date & year of IEC PV qualification certificate, Name of the test lab issued IEC certificate. The PV modules used in the solar power projects must qualify to the latest edition of the following International Electro technical Commission (IEC) P module qualification test or equivalent BIS Standards. The PV module must be tested and approved by one of the IEC authorized test centres. 115 (b) Material and labour for Module Mounting structure (MMS) fabricated from hot dip galvansied iron section of suitable size with specified tilt angle according to site requirement & optimum angle to achieve maximum benefit of solar energy and suitable to withstand 180 Kmph wind speed all as per approved design parameters as per MNRE standards and to match with the existing site conditions. Necessary roof treatment to avoid any seepage in future shall be done by the Contractor and the amount included in the rate quoted. The roof tiles shall be dismantled and refixed back in original position. Structure shall be built with brick masonry basement of adequate size as per direction at site including all necessary civil work required for the foundation.(c) Supply, laying & Testing of DC cable minimum size 4/6sq mm multi stranded copper conductor, conforming to relevant IS, weather proof UV resistant with operating temperature up to 120 degrees, minimum rated voltage 1100 volt for inter connection of SPV Modules to array junction box including suitable size of cable lugs, male & female MC4 connectors & joints etc.(d) Supply, installation test and commissioning of protection devices MCCB 400 A, isolator and three phase 4 wire LT energy meter, array junction boxes having rating 150 KWp with over voltage protection and surge protection.(e) Supply, installation, test and commissioning of Grid tie Solar Power conditioning unit / inverter of minimum capacity 150 KWp(DC to AC 415 V in Three phase system) all as per approved design parameters & capable of generating output voltage 415 V AC at rated load condition with efficiency not less than 98 %, conforming to IEC 600682-2 NDE standards with power reduction, LVRT with protections for anti-islanding, Ground fault monitoring, Grid Monitoring, AC & DC Over voltage and under voltage protection, AC & DC short circuit lover current protection and DC reverse polarity protection, graphic display etc. all as specified and as directed.(f) Material and labour for Earthing for Lightning protection for SPV modules etc as per IE rule, MNRE guide line & BIS all as per approved plan complete with galvanised earth plate electrode 600x600x6 mm thick buried directly in ground vertically (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected to and including Gl strip 32x6mm size protected with Gl medium grade pipe 40mm dia for earth electrode up to test point by means of GI nuts, bolts, check nuts and washers including earth work excavation, PCC (1:3:6) type Cl pit and RCC cover ( 1:2:4) type Bl and funnel, with necessary charcoal, salt etc complete. 116 (g) Supply and fixing aluminium strip of size 25 x 3mm thick for roof / down conductor fixed on insulators/ saddles of suitable size for SPV modules lightning protection upto interconnection between Roof top LA to Ground Earthing system. (h) AC Cable: Supply and laying of 150 Sqmm LT XLPE insulated, screened PVC bedded, sheathed with multi-stranded aluminium conductor armoured with galvanised steel wire 1100 volts grade heavy duty conforming to IS 150 Sqmm x 3.5Core as per site requirement.Note (i) :-(a) Before quoting the bid, Contractor or his authorised Engineer/consultant must visit the proposed site to study the site condition.(b) Before commencement of work, contractor shall submit drawings & lay out plan with scale including required qty to Accepting Officer for approval.Note(ii):-(a) The mechanical structures, electrical works and overall workmanship of the Grid solar power plant must be warrented for a minimum of 5 years.(b) All Mechanical, Electrical works shall be carried out as per relevant BIS/lS equivalent standard norms only and also in accordance with the latest edition of the Indian Electricity Act / rules formed thereunder and as amended from time to time.(c) Any other works (mechanical, electrical & Civil) connected to installation, testing & functional requirement of solar photovoltaic power plant of capacity 150 KWp (AC) all as mentioned above and which is not mentioned or included in this Schedule A but required at site necessary shall be carried out by the contractor and quoted rate shall deemed to included for the same(d) Contractor shall provide adequate Spares/items required for minimum period of 1 year maintenance including DC & AC items under scope of work.Note (iii) : Design report shall be submitted before execution of Work at site by the contractor toGE for his scrutiny / comments and futher submitted to AO for obtaining approval. 117 DG SETSupplying, installing, testing and commissioning, factory assembled silentDiesel Engine driven generator set, fully wired alternator AC to give an out put of 400 KVA continuously rating at a power factor 0.8 lagging, 3 phase 4 wire, 415 volts 50 Hzsupply, 1500 RPM, directly coupled with diesel engine liquid cooled mounted on common base frame complete with floor mounting fuel tank (service tank) of adequate capacity with fuel line & accessories, PCC foundation work as per manufacturers instructions, vibration damper pads, control panel & other accessories etc and comprising of following.(a) Diesel Engine: Liquid cooled turbo charged with after cooler to deliver suitable BHP at 1500 RPM under NTP conditions of BS 5514 and conforming to IS 10001/ 10002, DIN 6271 & ISO 3046 with an overload capacity of 10% for one hour in any 12 hours continuous operation with the following accessories: Diesel engine of rated speed at full load electric start developing with system with radiator and including electronic governor control of class A1, engine control panel, lub oil pump, water pump, fuel tank, exhaust pipe with silencer and suitable for electric start with batteries ofadequate capacity and suitable for alternator of specified capacity complete with fly wheel direct/flexible coupling and coupling guard complete.(b) Radiator with blower fan or heat exchanger with guard.(c) Pipe coupling for engine cooling system piping.(d ) Corrosion inhibitor coolant(e) Paper element filters(i) Fuel filter(ii) Lube oil filter(iii) By pass(f) Fly wheel housing and fly wheel to suit alternator.(g) Engine bearing mechanism in fly wheel housing.(h) Shut off coil with safeties for LLOP/HWT/over speed.(i) Dry type air cleaners and vacuum indicators.(j) Residential silencers.(k) Stainless steel exhaust flexible bellows. 118 (l) Battery charging alternator.(m) Exhaust piping made out of STIC C class, MS pipe inclusive of all accessories and hardware, necessary supports scaffolding as per manufacturers recommendations to sustain back pressure with rain cap.(n) Mineral wool insulation 2 inch thick suitable for 400 degree Celsius temperature cladded with aluminium sheet of30 gauge for the entire length of exhaust pipe.(o) First fill of oil, coolant and diesel during commissioning and 12 hours testing.(p) Interconnecting copper cabling of adequate capacity batteries control.(q ) Fuel pipe class STIC 1 /1.5 /2 dia - 01 lot(r) Self starter 24 volts DC.(s) Electric operated electronic governor.(t) Fuel injection pump.(u) Electronic instrument panel, complete with all accessories as per manufacturers specifications displaying the following:-(i) 12vx2 nos -24V Battery. (ii) Water temperature.(iii) lubricating oil pressure.(iv) Engine speed -1500Rpm(v) Engine hours(vi) Frequency.(vii) Voltage.(v) Safety control (Trip and indication).(i) High water temperature(ii) Low lube oil temperature(iii) Overspeed stop 119 (w) Base frame: Sturdy, fabricated welded construction, channel iron base frame (duly painted) for mounting engine and alternator as per manufacturers design alonwith AVM pads.(x) Battery:-24 volts(2x12v Battery) DC, 180AH, maintenance free battery conforming to IS:14257 with leads & terminals (Make- Excide/Amron).(y) Fuel tank:12 hrs. full load diesel storage capacity fuel tank with mounting brackets factory made of 5mm thick HR/MS sheet with level indicator fuel inlet, fuel outlet, air vent, drain plug, inlet arrangement for diesel filling for exterior canopy (without opening its panel) etc complete all as specified and directed.(z) Isolator panel with 630 amp MCCB(aa) Auto logic panel for automatic stat(ab) Alternator: Alternator suitable rated for 400 KVA, 0.8 pf , 415 volts, 3 phase, 4 wire, 50 Hz at 1500 RPM, self excited and self regulated with AVR brushless, screen protected, drip proof, insulation class-H, IP -23, voltage regulationgrade - VG 3 self ventilated and conforming to BS: 5000 / IS: 4722 suitable for engine as mentioned here-in before, conformig to IS: 13364(part-1)Make: KOEL GREEN / stampford/crompten/kirloskar/Greaves(ac) Acoustic Enclosure:- M & L for acoustic enclosure for the above 400 KVA DG set to reduce noise level to 75 dB measured at 1.0 meter distance for audible frequencies as per guide of Central Pollution Control Board andmanufacturers specification and comprising of following from authorised GOEMs of Gen Set manufacturers specified :-(i) Sound insulation : 100mm thick Rock wool (Density 64 Kg/Cum).(ii) Outer body : 1.6mm thick CRCA(iii) Door : 1.6mm thick CRCA(iv) Base frame : ISMC 300(v) Inside illumination : 1 No.- 1 x 18 watt LED fitting of make Phillips/ Bajaj/ Crompton.(ad) AMF Control panel:- Factory fabricated cubicle type, free standing, floor mounted, indoor type, IP-43, AMF control panel, provided with removable rear panels & hinged front panel for easy accessibility, fabricated out of not less than 2.0mm thick CRCA sheet including two coats of powder coated paint over a coat of red oxide primer etc and comprising of following: 120 (ae) AMF control circuit with 4 pole MCCB 630 Amps - 2 nos, with ultimate breaking capacity Icu-50 KA at 415 volts and microprocessor release conforming to IEC 60947 Part-I with breaking capacity Ics=Icu at 415 volts , thermal overload setting 70% to 100%, short circuit setting 5 to 10 times-02 Nos. for main supply & DG set supply with HRC back up fuse complete with all DC control relays/ Line voltage monitor (LVM) as per OEM specifications incorporating motorised stored energy operating Engine start, stop, three attempt starting facility and failure to start etc.(af) Digital load manager : Three phase 4 wire indicating V,I,PF, KVA, KW, F of Enercon make with serial communication port model No. EM6400 with class 1.0 accuracy meter or equivalent make suitable rating of CT per phase- one No.(i) Indication lamp R, Y, B with 3 Nos. of 2A HRC fuses-10 sets.(ii) Bottom gland plate for incoming and outgoing cables.(iii) Circuit diagram plate.Note:- DG set should be as per CPCB- 4 latest norm wef 01 July 2023 of National Clean Air programme (NACP) Act 1981.The contractor shall procure the item within the period given by CPBC in case of revision in CBPC norms. Nothing extra will be paid on account of delay from the part of contractor. DG set shall have an exhaust with stack height of minimum 2m from the top of generator with a cowl. Smoke released from the exhaust of the DG sets indicating that emission parameters are within permissible limits, as prescribed by CPCB, demonstrating compliance with emission limits prescribed by CPCB 2016. 121 Supply, install, test and commissioning of LT Panel, Indoor type, powder coated, 2.00 mm thick CRCA Sheet, CPRI approved having, IP 43, MS angle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with Horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natuaral flow of air. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 1.6 mm thick CRCA Sheat duly compartmentalised for each control gear with louvers and air vent gasket for natuaral flow of air and suiatable provision to accomodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables.Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, track resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. Feeder Panel No.1 (DG Panel ) 122 Incoming:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 630 Amps, breaking capacity 36 KA - 01 No. Ics =100% IcuMetering Unit:- (a) R Y B Indications (LED Type) - 1 sets(b) Digital Multi function meter - 01 No.(c) CTs - 800/5A, CL-1,15 VA - 1 set(d) Horizontal aluminium bus bar for 3 phase 440 V, 50 Hz, 4 wire system of rating 800 Amps for phases and 800 Amps for neutralOutgoing:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 400 Amps, Ics =100% Icu breaking capacity 36 KA- 03 No. (for Package AC Bulk Store, pump house and fire pump & spare)(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 160 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for Pump House & Fire Pump)(c) MCCB, thermal magnetic release, 4 pole, 415 Volts, 80 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for Incianator)(d) MCCB, thermal magnetic release, 4 pole, 415 Volts, 32 Amps, Ics =100% Icu breaking capacity 25 KA- 07 No. (for Terrace pump 1, Terrace pump 2, Power House, High mast 1, High mast 2, Street Light)(e) Digital Ammeter with suitable CT for each outgoing(f) Astro Time switch for 3 phase 20A- 1 No(g) 3 Phase Power contactor 20 amps, with 230 coil 123 SEWAGE DISPOSALM & L for laying of DWCPE sewage pipes line 200 mmdia borepipe sftiffnessclass SN 8 includingsealing of joints fittings etc complete with collers complte all as spcified and directed 124 M & L for laying of DWCPE sewage pipes line 150 mmdia borepipe sftiffnessclass SN 8 includingsealing of joints fittings etc complete with collers complte all as spcified and directed 125 COMPOUND WALLS & F Concertina Coil of 600/700 mm outer dia made out of 2.60 mm dia spring steel wire dipped in corrosion preventive fluid (rusilo 901) of castrol make each coil having min 50 turns (circles) covering 6 m and an average weight not less than 8.57 Kg (plus or minus 5 %) incl handle and spike at both ends of coil erected in position on top of mild steel angle by fixing with 1.70 mm GI wire for securing, coil with fish hook bars, incl necessary welding to MS Sections etc all as specified and directed. 126 GREEN BUILDING NORMS(GRIHA CONCEPT)Supply and Install Organic Waste Converter fully automatic having capacity 50Kg/day, having internal tank made of high quality stainless steel while external panels are powder coated for enhanced product life with necessary electric control panel, cabling necessary civil works for installing machine etc with following requirements:-Type of machine: Fulley automatic in-vessel composterComposting method: 24 Hrs. Micro-organisms-based compostingmachine Type of microganism used: Heat resistant thermophilic bacteria Final Output: Dry organic Soil conditioner/Soil supplementsCycle time: 24Hrs Volume reduction in 24Hrs: 80-85% Internal tank: Stainless steel type Main agitator Shaft: Stainless steel type Input voltage: 415VSpecial features: VFD as standard across all models, Touchscreen standards Daily waste processing: 150Kgs Rated capacity: 7KWPower consumption (KWH par cycle): 13-15Length: 1650, Width: 850,Height: 1455 127 Supply, installation, testing and commissioning Three phase energy meter with the following specifications: Microprocessor based three phase, smart electricity meter, equipped with a bi-directional cellular (NB-IoT) communication that allows it to interact with the head end system (HES) for data collection and configuration with adequate security including electronic static pre paid cum postpaid energy meter rating 415 Volts, 50 Hz of range 10-100 Amps, complying to IS16444:2015 (reaffrimed 2020) and conforming to IS 3779 with LED display and parameters like Voltage, Current, Frequency, Power, Power factor, KWH/KVA, default in built dual source, inbuilt long range (LORAWAN) Communication suitable for outdoor LoRa data accumulator and also compatible for Prepaid and Postpaid online energy monitoring billing system with disconnection /reconnection through remote software / data export to ERP complete with 5 Years warranty.Note:(a) The Energy Meter to be capable of running in both prepaid and postpaid mode.(b) The meters to carry 5 year warranty. (for entire system) 128 Supplying, Fixing, Commissioning and testing of configuration of cloud Hosted multi user web based software with following modules:(i) Head End System (HES): to acquire meter data automatically from DCU sand monitor parameters acquired from meters.(ii) Meter Data Management ModuleThe meter data management module would be responsible for collecting the data from the data concentrator and make the data available to the billing system. The system would support offline meter(a) 30 min instantaneous data from all the meters for seven parameters Cumulative Energy. Cumulative Apparent Energy (as applicable), Power, Current, Voltage, Power Factor and Frequency(b) Monthly billing survey data for cumulative energy and max demand(iii) Billing Module: The billing module would collect the data from the meter data management module, calculate the energy consumption, calculate billing determinant and make energy data/billing data available to admin and end users. The billing module would include functionalities for tariff setup, bill format setup, bill adjustment, occupation billing and vacation billing. It would allow postpaid and prepaid functionality as required.(iv) Occupation and Vacation Module: The system would support occupation/vacation based on the unit catagories. The system would support automatic data capture on occupation and vacation events.(v) Website: There would be a dedicated website forAGE/GE and BSO team to view all the data and information alongwith customer portal for use of customer. The designated users in MES would have the admin access to the application. The MES Staff would also have the access to the key information on mobile App (AndroiandiOS based) for admin use complete all as specified and directed.(vi) Customer Module: The system would include a customer portal for the resident/occupants to login and view their own energy /billing data and recharge facility. There shall be consumer App (Android and iOS based) also to log in and view their own energy/billing data and recharge facility.(vii) Communication Module :The system would provide communication of energy data and bills via print, email and sms methods. 129 (viii) Meter Master Data: The system would support meter data repository. The system would support meter replacement process.(ix) Excel Export: the system would support export of metering and billing data in excel and pdf format.(x) Energy Accounting module: The system would include features of energy accounting, the system would to able to account for total energy block wise, facility wise and would also allow calculations of the unaccounted energy in case total energy meter is also available.(xi) Prepayment/Recharging Facility:The system should periodically monitor the energy consumption of prepaid consumers and decrease the available credit based on the consumption. The system should allow online/digital recharging through consumer App (Androidand iOSbased) and Web portal. The configuration and necessary arrangement for payment gateway and E-MRO facility shall be deemed to be included in the quoted rate. The system should sendconnect/disconnect command on the basis of available credit.Low credit alarm: The system will give an alarm over the consumer App and SMS to the registered mobile number in case the credit in the meter goes down be low apredefined limit.Emergency credit: The meter will work even when the credit falls down to zero to prevent disconnection. This limit shall be configurable. The system should support happy hours inorder to prevent disconnection in non working hours and on holidays. The Happy hours should be configurable complete all as specified and directed. 130 Supply, Installation, Testing and Commissioning of DCUs/Gateways and the arrangement of Sim cards or Internet to enable reliable medium for two-way communication between Smart Meter & HES. The data acquisition (Push/Pull) frequency shall be, configurable. It shall push events such as tamper, power off etc. to HES immediately on occurrence/receipt from meters. It shall have provision for the cellular, WiFi and Ethernet communication for the backhaul to HES. It shall be capable to handle data of minimum 1000 Nos. of any type of smart meter (1ph/3ph).It shall be able to communicate with the nearest meters at a distance of at least 500 m, depending on topographical features. Communication of the nearest meters with other meters shall be established through appropriate mesh formation. RF Mesh shall support self-forming and self-healing features. The equipment shall be weather proof and dust proof (minimum rating: IP54 for indoor and IP65 for outdoor installation). It shall have rechargeable battery with backup for 1(one) hour for normal meter reading, to push tamper event, carry out on demand reading, etc complete all as specified and directed. 131 Hosting GPRS (4G) charges for Gateway for five years from the date of completion F Including 2 years waranty and 2 years Maintinance after warranty) Make:-Airtel/Jio/Vodafone 132 Supply and installation of digital Water flow meter 50mm suitable for domestic and commercial applications complete all as specified and directed. 133 Supply and installation of digital Water flow meter 40mm suitable for domestic and commercial applications complete all as specified and directed. 134 ARBORICULTUREM & L for excavation of pits size 30cm x 30cm x 30cm in loose soil and filling the pit with mixture of river sand and approved top soil in the proportion of 1:3 mixed with 30% of cow dung powder, 100gms of bone meal and 100gm of neem cake powder 135 All as per item No 13.121 above but pit size 60cm x 60cm x 60cm 136 Supplying and planting red palm or royal palm healthy sapling having 45cm height and shall have a minimum height of 65cm after 6 months 137 Supplying and planting coconut tree healthy sapling having 75cm height and shall have a minimum 95cm after 6 months. 138 Supplying and planting flower plants(Champa/ hybrid hibiscus/ Hybrid west Indian Jasmine/ Hybrid Plumeria white plant/ Panama yellow plant/ Oleander) healthy sapling having 10cm minimum height and shall have a minimum 25cm to 30cm height after 6 months. 139 Supplying and planting phylanthus healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 140 Supplying and planting bougainvillea colour flower plants healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 141 Supplying and planting song of India flower plants healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 142 Supplying and planting dracaena flower plants healthy sapling having 15cm to 30 cm height and shall have a minimum 60cm height after 6 months. 143 Supply and planting mexican grass including providing manure as directed. 144 PILE FOUNDATIONBoring 450 mm dia piles to any depthin any type of soil/ strata by anyapproved method, complete all as shown on drawings and as specified anddirected.Note:- The quoted rate shall include for mobilization and demobilisation of piling equipment, making approaches to site or point of pile boring if necessary. Nothing extra shall be paid on this account. 145 Boring for bored cast in situ pile 600 mm dia to any depth through any type of soil / strata, using DMC method (Direct Mud Circulation)and getting out & disposal of spoil to any distance outside of MD land , complete all as specified and as directedby the EngineerIn Charge 146 M & L Reinforced cement concrete of grade M-35 design mix (RMC) as per IS-456using 20 mm graded stone aggregate in cast in situ DMC bored pile of any length / any sectionscomplete all as specified and as shown on drg 147 M & L Reinforced cement concrete of grade M-35 design mix (RMC) as per IS-456using 20 mm graded stone aggregate in pile caps / grade beams complete all as specified and as shown on drg 148 Providing TMT bars (CRS/HCRM/CRM) in reinforcement 10 mm dia and over for bored cast in situ piles of any length and any dia all as shown on drgs including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with and including 0.9mm dia MS wire (annealed) or welding so as to secure the bar firmly in position/ required shape complete all as specified and shown on drgs (Fe-500D). 149 Providing TMT bars (CRS/HCRM/CRM) in reinforcement 10 mm dia and over for pile caps and grade beams, cut to length, bent to shape required, hooking ends and binding with and including 0.9mm dia MS wire (annealed) or welding so as to secure the bar firmly in position/ required shape complete all as specified and shown on drgs (Fe-500D). 150 All as per item No 13.136 here-in-before but5mm dia and over upto and including 10mm dia as in helicals for piles and stirrups for grade beams complete all as specified and directed. 151 M & L for providing PCC (1:4:8) type D-2 using 40 mm graded stone aggregate for concrete layer below pile caps foundation complete all as specified and directed. 152 Formwork to sides of pile caps/ grade beams and similar work, rough finished surface of concrete flat all as specified and as directed. 153 M & L for carrying out non destructive integrity test all as per IS 2911 (Part 4) 2013 for 600 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed all as specified and directed. 154 M & L for carrying out non destructive integrity test all as per IS 2911 (Part 4) 2013 for 450 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed all as specified and directed. 155 M & L for carrying out Initial Load test (vertical load test) cast in situ piles of 600 mm dia as per IS 2911 (Part 4) 2013 including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note :- Providing and installing test piles shall measured and paid separately) 156 M & L for carrying out Initial (lateral load test) cast in situ piles of 600 mm dia as per IS 2911 (Part 4) 2013including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note :- Providing and installing test piles shall measured and paid separately) 157 M & L for carrying out Initial load test (pull outtest as per design load) of cast in situ piles of 600 mm dia as per IS 2911 (Part 4) 2013including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note :- Providing and installing test piles shall measured and paid separately) 158 M & L for carrying out Routine load Test (Vertical load)all as per IS 2911 (Part 4) 2013 for 600 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed 159 Testing of piles Initial load test (verticle load test) for 450mm dia cast in situ bored piles all as per IS including removing the testing equipments from the site after testing is completed all asspecified and as directed 160 M & L for carrying out Initial Load test (lateral load test) cast in situ piles of 450 mm dia as per IS 2911 (Part 4) 2013 including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note:- Providing and installing test piles shall measured and paid separately) 161 M & L for carrying out Initial load test (pull outtest as per design load)of cast in situ piles of 450 mm dia as per IS 2911 (Part 4) 2013including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note :- Providing and installing test piles shall measured and paid separately) 162 M & L for carrying out Routine load Test (Vertical load)all as per IS 2911 (Part 4) 2013 for 450 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed
Contract Date : 11 Feb, 2026   |   Contract Value : 59.27 Crore
BRR : 7636241 Tender For Provision Of Cgsd (Kochi) At Willingdon Island, Kochi; 1 SCHEDULE A Part - I (BUILDING & STRUCTURE WORKS)Details of prepriced schedule is given in tender documents. 2 SCHEDULE A PART-II ( SITE CLEARENCE/DEVELOPMENT & EARTH WORKS) Details of prepriced Schedule is given in tender documents. 3 SCHEDULE A PART-III (INTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents. 4 SCHEDULE A PART-IV (INTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents. 5 SCHEDULE A PART-V (FIRE FIGHTING)Details of prepriced Schedule is given in tender documents. 6 SCHEDULE A PART-VI (ROAD/PATH/ HARD STANDING/CULVERT)Details of prepriced Schedule is given in tender documents. 7 SCHEDULE A PART-VII (EXTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents. 8 SCHEDULE A PART-VIII (EXTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents. 9 SCHEDULE A PART-IX (SEWAGE DISPOSAL) Details of prepriced Schedule is given in tender documents. 10 SCHEDULE A PART-X (AREA DRAINAGE) Details of prepriced Schedule is given in tender documents. 11 SCHEDULE A PART-XI (COMPOUND WALL) Details of prepriced Schedule is given in tender documents. 12 SCHEDULE A PART-XII (ORGANIC WASTE CONVERTER AND SMART ENERGY METER) Details of prepriced Schedule is given in tender documents. 13 SCHEDULE A PART -XIII (MISCELLANIOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as Rs 0.00 under Col. E signifies this fact only. 14 INTERNAL WATER SUPPLY S & F for 15 mm dia bore CP two way bib cock with CP wall flange (Make : Jaquar Model No. OPP15041PM / Eqvlt in Kohler/Grohe), cast copper alloy, screwed down high pressure with crutch screwed both ends for CPVC pipes or for union and fixed complete all as specified and directed by Engr-in-charge. 15 S & F for 15 mm dia bore CP bib cock with CP wall flange (Make : Jaquar Model No. OPP15037PM / Eqvlt in Kohler/Grohe), cast copper alloy, screwed down high pressure with crutch, screwed both ends for CPVC pipes or for union and fixed complete all as specified and directed by Engr-in-charge. 16 S & F for 20 mm bore concealed Stop cock reqular brass body with spindle extnwith Exposed Part Kit of Concealed Stop Cock with Fitting Sleeve, Operating Lever & Adjustable Wall Flange (Compatible with ALD-083CQT & ALD-089CQT)(Make : Jaquar Model No. ALD 089 CQT/ Eqvlt in Kohler/Grohe), cast copper alloy, screwed down high pressure with crutch , screwed both ends for CPVC pipes or for union and fixed complete all as specified and directed by Engr-in-charge. 17 S & F for 25 mm dia bore concealed Stop cock reqular brass body with spindle extn with Flush Cock & Wall Flange 25mm Ceramic Disc Cartridge) with Plain Knob (Make : Jaquar Model No. ALD 081/ Eqvlt in Kohler/Grohe), cast copper alloy, screwed down high pressure with crutch, screwed both ends for CPVC pipes or for union and fixed complete all as specified and directed by Engr-in-charge. 18 S & F 20mm bore CP angular stop cock with CP wall flange (Make : Jaquar Model No. CQT 23053 / Eqvlt in Kohler/Grohe), cast copper alloy, screwed down, high pressure with crutch, screwed both ends for iron pipe or for union and fixed 19 S & F for 100 mm overhead shower rose round shape single flow (ABS Body chrome plated with gray face plate (Make : Jaquar Model No. 1989 with SHA 479L300S / Eqvlt in Kohler/ ESS ESS) with Shower Arm ø20mm & 300mm Long Round Shape with 90˚ Bend for Wall Mounted Showers with Stainless Steel connected to pipe complete all as specified and directed by Engr-in-charge. 20 COOLING APPLIANCESDesign, Supply, Installation, Testing and Commissioning of Invertor Type Floor Mounted Packaged AC Units of specified capacities, combination of energy efficient Inverter compressor plus fixed compressors, nominal capacity condensing unit with all standard fittings, safety devices, like HP/LP cutout, single phase preventor, overload relays, R-410A Gas, vibration isolation pads etc. Suitable to work till 50 Deg ambient, Blue Fin Condensor and Corrosion Resistant Body, Wide Voltage Range 360V - 440V, The quoted rate shall include Group controller also asrequired for controlling AC from a single point and timer option for load sharing of AC units complete all as specified and as directed by Engineer - in - charge, of following capacities.Note: Design report shall be submitted before execution of work at site by the contractor to GE for his scruitiny/comments and further submitted to AO for his approval.Make: Blue Star/Daikin/Haeir/Godrej/Voltas/Equivalent. (HIGH SIDE (MACHINES))(Outdoor unit) 21 a) 22 TR Inverter Package AC Units 22 b) 16.5 TR Inverter Package AC Unit 23 Design, Supply, Installation, Testing and Commissioning of Normal Type Floor Mounted Packaged AC Units of specified capacities, nominal capacity condensing unit with all standard fittings, safety devices, like HP/LP cutout, single phase preventor, overload relays, R-410A Gas, vibration isolation pads etc. Suitable to work till 50 Deg ambient, Blue Fin Condensor and Corrosion Resistant Body, Wide Voltage Range 360V - 440V, The quoted rate shall include support works for outdoor units with necessary catwalk for service access complete all as specified and as directed by Engineer - in - charge, of following capacitiesNote: Design report shall be submitted before execution of work at site by the contractor to GE for his scruitiny/comments and further submitted to AO for his approval.Make: Blue Star/Daikin/Haeir/Godrej/Voltas/Equivalent. LOW SIDE (MACHINES))(Indoor unit) 24 a) 22 TR Inverter Package AC Units 25 b) 16.5 TR Inverter Package AC Unit 26 Supply, Installation and Testing of Refrigerant pipingwith necessary clamping (suction & Discharge) Hard/Soft drawn Copper tube of suitable sizes, with copper elbows, tees, Tubular Nitrile Insulations etc as required complete all as specified and as directed by Engineer - in - charge. 27 S & F Control Cabling B/W Indoor & Outdoor units 28 M & L Refrigerant Gas - R410A 29 Supply, Installation and Testing of Hard PVC drain piping. Drain piping with Tubular Nitrile Rubber Insulation: complete in all respects, well clamped till drain Points complete all as specified and as directed by Engineer - in - charge. For All Units 30 DUCTINGSupply, fabrication, installation, testing of GI rectangular ducts, complete with all fittings such as tee, bends, special off shoots, inspection doors, transformation pieces etc. as required as per IS 655 including suspension and supporting arrangement for plenum, duct etc. required complete all as specified and as directed by Engineer - in - charge. 31 a) Using 0.63 mm (24 Gauge) GI sheet 32 b) Using 0.80 mm (22 Gauge) GI sheet 33 c) Using 1.00 mm (20 Gauge) GI sheet 34 DUCT INSULATION & LININGSupply and Installation of Acoustic Insulation of ducts using 9MM Open Cell Nitrile Rubber, well adhesived, 150 - 180 Kg/cm2 complete all as specified and as directed by Engineer - in - charge. 35 Supply, installation & testing of Thermal Insulation of ducts using 9MM Closed Cell Nitrile Rubber, well adhesived, 40-60 Kg/cm2 complete all as specified and as directed by Engineer - in - charge. 36 S & F Canvas Connection 37 AIR DISTRIBUTION PRODUCTSSupply and Fixing of Powder Coated Aluminium Grills/ Diffusers (Supply/ Return) complete all as specified and as directed by Engineer - in - charge. 38 S & F Collar Dampers 39 Supply and Installation of Fire Dampers complete all as specified and as directed by Engineer - in - charge. 40 Supply, Installation, Testing and Commissioning of Heater Bank Plus Humidistat Arrangement complete all as specified and as directed by Engineer - in - charge. 41 Supply and fixing, testing and commissioning water coolerhaving stainless steel body with inbuild purifier HIMA 7 NHC, dispencing capacity 125 ltr/hr and storage tank capacity 40 ltr normal and 40 cold electric driven (single phase), 230 volt, AC power supply with all connecting accessories complete all as specified and directed. 42 Supply and fixrefrigerator, electric driven (single phase), 220 V,50 HZ, capacity 195 Litres, 3 Star rated direct cool inverter, single door all as specified and directed by the Engineer-in-Charge. 43 Supply and install, testing and commissioning of split type air conditioner 1.5 TR Capacity of invertertechnology 5 star rating with cordless remote control single phase 240 volts complete with all accessories such as indoor and outdoor units and refrigerent tubing of adequete length as required at site indoor mounting plate, duly powder coated fixing with anchor bolts at any height, drain pipe of suitable size brought to ground level from any height, initial filling of refrigerent gas including making round hole on existing wall for taking up refrigerent tubing, drain pipe, cables, etc and making good the disturbed surface by matching with existing adjoining surface complete all as specified and directed (Cooling appliances- qty 4, Air conditioning- qty 10) 44 Supply and fix Voltage stabilizer 3 KVA for automatic operation, single phase naturally air cooled indoor type, wall mounted & designed for input variation between 170 V to 280 V with output voltage stabilized at 230 V with accuracy of ± 2.5% 45 Supply and fix Voltage stabilizer 4 KVA for automatic operation, single phase naturally air cooled indoor type, wall mounted & designed for input variation between 170 V to 280 V with output voltage stabilized at 230 V with accuracy of ± 2.5% (Cooling appliances-qty4, Air conditioning- qty 10) 46 AIR CONDITIONINGSupply and install,Testing & commissioning of split type air conditioner 2 TR capacity of inverter technology 5 star ratingwith cordless remote control, single phase 240 volts complete with all accessories such asindoor and outdoor units and refrigerent tubing of adequete length as required at site, indoor mounting plate, duly powder coated fixing with anchor bolts at any height, drain pipe of suitable size brought to ground level from any height, initial filling of refrigerent gas including making round hole on existing wall for taking up refrigerent tubing, drain pipe, cables etc and making good the surace by matching with adjoining surface complete all as specified and directed. 47 Supply and fix Voltage stabilizer 5 KVA for automatic operation,single phase naturally air cooled indoor type, Wall mounted type & designed for input variation between 170 V to 280 V with output voltage stabilized at230 V with accuracy of ± 2.5% 48 INTERNAL ELECTRIFICATIONS & F LED Mirror light 1 x 5W LUMOS ECCO 1 feet Make: Luker or Equivalent 49 S & F modular MCB DBOx 3 Pin Socket with MCB SP 20 Amp, 240 V including plastic enclosure as per manufacturer instruction fixed on wall surface complete for Air conditioner all as specified and as directed. (Make:-Havells, Model-DHDMCSN0251016 or equivalent) 50 Supply and fix Air circulator of 600 mm sweep AC single Phase. 230V, 1440 RPM complete all as specified and as directed. (Make: Havells model, Turbo Force Wall or equivalent) 51 S & FVertical triple pole & neutral (VTPN), double door, 16-way metallic modular distribution board conforming to IEC 61439-3, suitable for flush / surface mounting with provision for FPMCCB as incomer and TPN/SP MCBs as outgoing, reversible metal door, 200 A copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wiriest & cable ties for cable management, profited masking sheet, etc. having IK 09 & IP 43 protection complete all as specified and directed. 52 S & FVertical triple pole & neutral (VTPN), double door, 4-way metallic modular distribution board conforming to IEC 61439-3, suitable for flush / surface mounting with provision for FPMCCB as incomer and TPN/SP MCBs as outgoing, reversible metal door, 200 A copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wiriest & cable ties for cable management, profited masking sheet, etc. having IK 09 & IP 43 protection complete all as specified and directed. 53 M & L for Flame ProofMCB Distribution board SPN 12 way, with case iron body, powder painted, with 200 Amps rated bus bar etc. including provision of one 32 Amps SPN MCB as incoming and 6 Amps SP MCB -10 Nos as outgoingcomplete all as specified and as directed. 54 M & L for Flame ProofMCB Distribution board SPN 8 way, with case iron body, powder painted, with 200 Amps rated bus bar etc. including provision of one 32 Amps SPN MCB as incoming and 6 Amps SP MCB- 6 Nos as outgoingcomplete all as specified and as directed. 55 Supply and fix Engage light with Green & Red LED complete all as specified and as directed 56 Supply and fix of CS mounted high intensity LED search light, long range, manually swivel in all direction, 250 W, minimum range 700 meters, Single, LED Efficiency> 140 lm/w, PF> 0.95, CCT 5500K - 6500K, Optical grade PMMA/PC lens/reflector efficiency>95%, multiple circuit to avoid complete run down, anti UV, narrow beam 5 degree, die cast LM6 body with air fins, powder coated, constant current, an average lux at 10 meter - 8000 lux with circle of approx 600 mm, working temp: -20 to +60 degree C, input Volt 100-300 VAC, 50 Hz, PF >0.95, IP-66, confirming to LM79/ LM80 and type tested as per IS: 10322/ IS: 13383, BIS approved and Govt lab tested for lux intensity. The search light is completed with manual revolving CS stand D20cm x H15cm (min.) with 3 nos. foundation holes for mounting of searchlight on watchtower structure, manual rotation of light on horizontally 360 degree with 45 degree tiltable with provision of both instant locking arrangement at desired position. Model No. CS-LRFLL-25PC25 of KALIN make or equivalent 57 Supply, install, testing and commisisong of outdoor floor/wall mounted thermoplastic polycarbonatefeeder pillar panel, Enystar EmptyEnclosures, IP-65, weatherproof, corrosion free, Halogen and Silicon Free, Frame retardant with Opaque Lid Size-[276 x 546 x 186]mm and Transparent Hinged Lid, completed all as specified and directed. 58 M & L for TV socket module metal flushed including flushed Box cover plate Box for 2 way module complete all as specified. 59 M & L for telephone jack with module metal flushed including flushed Box cover plate Box for 2 way module complete all as specified. 60 Supply and lay coaxial cable for TV Cabledrawn through conduit 61 S & F flame proof exhaust fan 300 mm sweep, single phase, 1440 RPM complete all as specified and as directed. 62 FIRE FIGHTINGSupply and fix Foot Valve conforming to IS 4038, 100 mmdia. 63 Supply and fix Foot Valve conforming to IS 4038, 150 mmdia. 64 Supply and fix Cast Iron Air Valves with single air Outlets, conforming to IS 14845 of size 100 mm dia bore and fixing up in Cast Iron Water supply mains of size 100 mm dia. 65 S & F sprinkler flexible drop pipe 1 mtr long. 66 S & F sprinkler rossette 25 mm dia. 67 Supply and installation, testing and commissioning of Analog Addressable type Active Loop Repeater (Loop power/external power) Fire terminal with inbuit turbo isolator, Backlit LCD Display 6x40 characters display, having Controls For Reset, Mute, Accept, Silence alarms and Self Test, with programmable free keys and Duly Approved byEN54/LPCB/VDS/FM Make: SIEMENS/NOTIFIER/BOSCH 68 M & L for Low smoke Zero helogen flame retardent fire alarm cable2 core, 1.5 mm² copper conductor confirming to BS7629-I, BS6387 & rated for 500 v grade having plaine sraded copper coductutor with priming insulation of glass mica fire resistance tape & secondery insulation of high performancesilicon rubber with electrostatic screen of aluminium fire barrier Type LT53 outer sheath confirming to BS 7655, red in colour drawn through & including concealed steel conduit including laying,fixing,connecting complete all as specified and directed. 69 Staircase signage down of make bajaj cat part no. 111499 model no. DSDWBB 3W double side display for staircase downwards (with 2 hours built in battery backup) complete all as specified and directed at site complete all as specified and directed. 70 S & F wall mounted LED emergency Exit signage luminaire Lit up using regular mains supply comes with a unique rechargeable Ni-Cd battery capable of emergency back up upto 05 hours(Cat No. 220211 Make Bajaj or equivalent to CG/Havells. 71 Supply, Installation, test and Commissioning CPRI APPROVED factoryfabricated, indoor type, LT panel board , made out of 2 mm thick CRCA Sheetsingle door withboth side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embeddedwith 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete withinternal connection with suitable size of cable, cable lugs and cable glandsPCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Testing after Installation includingcomplete all as specified and comprising of the following:- Make of MCCB/MCB -MDS/LEGRAND/L&T/HEGGER (Main Fire Fighting Panel)INCOMING(i) MCCB 4 Pole 160 amp 50 Hz, 415 V with reputing capacity 35 KA with microprocessor based release - 01 No.(ii) Voltmeter Digital type 0-500 Volts range flush type with selector switch- 01 No(iii) Aluminium Bus bar TPN - 200 amps- 1setOUTGOING(i) MCCB 3 Pole 125 amp 50 Hz, 415 V with reputing capacity 35 KA with microprocessor based release- 01 No.(iii) MCB TPN 32 Amp -02 Nos(iv) 80 HP S/D STARTER- 01 Nos(v) DOL STARTER 7.5 HP- 01 Nos(vi) Motor Protection Relay32-88 amps- 1 no. (vii) Motor Protection Relay2-5.5 amps- 1 no. (viii) On/Off/Trip Indication Lamps, 220 V AC- 6 nos.(ix) Start/Stop Push Button, 2 No. (x) Phase indicating lamps RYB for incoming and each outgoing connection.(xi) Digital type Ammeter 0- 150 amps with selector switch and CT coils of suitable capacity for incoming and each outgoing connection- 1 no. 72 M & L for coating and wrapping of under ground steel pipe buried in soil shall have protection against corrosion as per IS-10221.The coating and wrapping shall be carried out in systamatic manner to get uniform thickness of coating as per IS specification 73 Supply, Installation, test and Commissioning CPRI APPROVED factoryfabricated, Indoor type, LT panel board, made out of 2 mm thick CRCA Sheetsingle door withboth side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embeddedwith 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete withinternal connection with suitable size of cable, cable lugs and cable glandsPCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Testing after Installation includingcomplete all as specified and & directedby Engr-in-charge comprising of the following :– ( Booster terrace pump panel)INCOMING:-(a) INCOMING MCCB 40 A 25 KA, 4 POLE- 01 No.(b) Busbar TPN of size 100 apms - 1 setOUTGOINGS:-(a) MCB 3 POLE TPN 32 Amps,10 KA-2 Nos.(b)DOL Starter for 7.5 HP Pump set-1 Nos.(c) Ammeter Class-1, digital panel mounting type 96mmx96mm L & T cat no WDS301FCA00 including CT 50X5 Amps 3 nos & selector switch-4 nos(d) Voltmeter Class- 1, digital panel mounting type 96mmx96mm L&T CAT NO.WDS301FEV00 & selector switch - 1 no.(e) LED TYPE indicator lamp 1 set (set of three for R,Y,B)(f) Mini protecrionRelay 4-11 amp - 1 nos. 74 Fire Extinguisher mechanical Foam type trolly mouted of 9 Liters capacity. Ceasefire 9 litrs fire Extinguisher AFFF Foam type, External Cartridge type, Pressure Guage Gross weight 14.6 Kg, empty weight5.6 Kg, Can height 611 MM, Diameter 175 MM, Discharge time less than 60 Secs controllable discharge mechanism, Minimum 6 Mtrs, Applicable on Class A, B, can construction deep down & CO2 Mig welded Valve Construction: Forging & Machining, Internal coating of can: Epoxy powder coating, External coating of can: Epoxy poyster powder coating sheet metal thickness 2.0MM,1 year warranty. Make Cease Fire Or Equivalent. (pol store) 75 Supply, Installation,Testing & commissioning of Carbon Dioxide (Co2) type fire extinguisher of 4.5 Kg confirm to IS: 15683, with ISI marked/TAC approved fitted with required accessories including wall suspension brackets. 76 Supply, Installation,Testing & commissioning ofDRY CHEMICAL POWDER (ABC) stored pressure type fire extinguisher of 9 Kg confirm to IS: 15683, with ISI marked/TAC approved fitted with required accessories including wall suspension brackets. 77 Supply, Installation,Testing & commissioning of Water Mist High pressure stored pressure type fire extinguisher of 9 Kg confirm to IS: 15683, with ISI marked/TAC approved fitted with required accessories including wall suspension brackets. 78 Supply and installation at approved location approved make Fire sand bucket of 24 gauge galvanized steel sheet, each set shall have 4 buckets with stand & Showel etc, complete. 79 SPECIAL EQUIPMENTS FOR STORESDesign, manufacture, Supply, installation, testing and commissioning of Automated Storage and Retrieval System with storage racks, pallets, stacking crane, computer hardware with compatible inventory software as a turnkey solution complete all as specified and directed. Automated Storage and Retrieval System shall consist of computer controlled & PLC stacker crane driven system for automatically placing & retrieving materials from defined storage locations. The crane shall be capable of lifiting, stacking and retriveing the pallet loads weight upto 1125 Kg (max) complete all as specified and directed by the Engineer-in-Charge. Technical data for design of heavy duty ASRS:-(a) Dimensions:-Height:10 Mtrs for racking system which shall be designed and constructed to store the required no. and size of pallets.(b)Storage capacity:-Pallet Size: 1300 (W) x 1200(D) x 1250 (H) in mmPallet Nos.: 480Pallet load capacity: 1125 KgTotal capacity: 540 Tons(c) Stacker Crane: Single mast automated stacker crane for handling Pallet, size 1300mm(W) x 1200mm (D) x 1250mm (H) and pay load (including Pallet self weight) of 1125 Kg max. The stacker crane shall be capable of picking up the pallet from in-feed conveyor or loading station and stacking it into empty slots of racking system. Similarly, it shall also be capable of retrieving the palltet from racking system and putting it on the same conveyor or unloading station. Stacker crane will be mounted on single rail at the bottom to traverse the length of the storage system. A single top rail mounted on the racking system shall also support it.General technical parameters of stacker crane:Technical parameters/Type- Single Mast(i) Operation mode (Networking)- On-line automatic / Single automatic (Ground/Boarding) /Manual operation (Boarding) / Maintenance (ii) Communication Means- Wireless 80 (iii) Power supply mode- 380 to 415 V, 50 Hz, three phase five wire (iv) Addressing mode- Horizontal and verticle operation: photo electrical sensor + bar code scanners(v) Positioning / Reduction accuracy (mm) level- lifting ± 3 - 5, Fork : ± 3(vi) Fork unit- 1 Double deep fork(vii) Load unit- MS Pallet (viii) Total Height- 10 Mtr(ix) The normal lifting speed (m/min) - 10 MPM(x) The normal running speed (m/min) - 65 MPM(xi) Rated load- 1125 Kg(xii) Receipt equipment fixed platform/conveyor/lifting /platform(electric/manual)- Conveyor(d) Pallets: to stack and retrieve the pallet weighing up to loaded pallet weight 1125 Kg at height up to the last loading level in the racking system. It should have retrieval mechanism to enable stacking & retrieval of pallet from either side of the rack and also to pick up the load directly from the loading station.Pallet Details:-(i) Dimensions - 1300mm(W) x 1200mm(D)(ii) Pallet height- 1250 mm(e) Racking system :- Two aisle having two row racking system each with 05 verticle levels for storage of material. Racking for double deep type storage of 480 Pallet of size 1300mm(W) x 1200mm (D) x 1250mm (H). Loaded pallet weight: Pay load with pallet 1125 Kg max. System details:-Working aisle -01 Nos. (Double deep)Store rack -24 Nos./RowTotal rack in 1 aisle-24 (Left) + 24 (Right)= 48 Nos.No. of level- 5 Nos/RackTotal Pallet-48 x 5 x 2 = 480 Nos.Load capacity- 1125 Kg/LevelSingle mast stacker crane-01 No. 81 (f)Aisle Equipment:-This will consist of electrical as well mechanical aisle equipments and willl be designed as per the pallet requirement. The mechanical Aisle equipment of bottom rail shall consist of I Beam and will be provided with adjustable calmps for holding the rail in position to ensure proper alignment. Top rail shall be mounted on the racking. The electrical aisle equipment shall consist of power rail (fully enclosed bus bar having 7 pole system), which is mounted on the racking system below the first loading level.(g) Details of rack members:-The racking system shall consist of cold-rolled steel sections as per manufacturers design to accommodate and store pallets and connected systems.(h) Loading- unloading station/ Conveyor(i) Pallet Load 1125 Kg max.(ii) Bearing- SKF Equivalent make(iii) Motor- Seimens/Sew Euro Drive/Nord Sew/ Bonfiglioli or equivalent(iv) Gear Box- Bonfiglioli Make or equivalent(v) V.F.D.- Yashkawa make or equivalent(j) All steel surface shall be powder coated finish with 8 tank treatment process.(k) Maintenence: The annual maintenence of complete ASRS system duyring the defect liability period of two years shall be included in the rate quoted for the system and the AMC contract duly signed with the manufacturer of the ASRS system shall be submitted at the time of handling over the system. The AMC shall include all spares and consumables etc required during the period of two years and nothing extra shall be paid on this accountNote- 1Mechanical safety provision (i) End of aisle shock absorbers / bumpers for stacker crane.(ii) End of travel buffer for the lifting crane.(iii) Safety catches on lifting carriage.(iv) Anti-tilt mechanism for the stacker crane.(v) Continuous rail cleaning brush for floor rail.(vi) Adjustable rail clamp to ensure alignment. 82 (vii) Resilient rubber pads on adjustable clamps for vibration dampening.(viii) Profile check on lifting carriage to check all three dimensions (width, depth & height) of the pallet. Note - 2 Electrical safety provision (i) There shall be Emergency stop push button at all panels and stations.(ii) Optical light beam amd mechanical safety sensor to stop the operation in case of improper storage or obstruction in the operator window either internal or external reasons like operator hand or material placed at edge of the tray.(iii) Back up circuitry for proper system operation.(iv) An electromagnetic brake shall be used to avoid the slippage of the hoist.(v) Stopper shall be provided for the maintenance door.(vi) Load cells shall be provided for the over weight of tray.(vii) Automatic door shall be provided for operator safety while machine in operating condition.Note - 3 Physical safety provision (i) The ASRS system shall comprise of safety fences having grid size of max. 40 x 40mm & wire dia should be of min. 3 mm. Height of the fencing should be minimum 2.0 meter.(ii) One No. of electromagnetic aisle access door shall be provided. It should cover the complete length of the system on one side.(iii) A manual locking system to restrict the movement of unauthorised personnel shall be provided.NOTE: Design report shall be submitted before execution of Work at site by the contractor toGE for his scrutiny / comments and futher submitted to AO for obtaining approval. Item No. 13.070 below shall be compatible with this item/ system and both should be integratedMake of ASR system:Armstrong Ltd/ Godrej Koerber/ Kardex India storage solutions Pvt Ltd/ Daifuku India Pvt Ltd/ Addverb technologies Ltd/ Craftsman Automation Ltd/ Tech-mark 83 Supply, installation, testing and commissioning of Advance Inventory Management System with computer hardware with compatible inventory software complete all as specified and directed by the Engineer-in-Charge. Technical specification of the system(i) System Height : 6400 (±100) mm(ii) System Width : 3150 (±100) mm(iii) System Depth : 2300 (±100) mm(iv) System Base : 7.24 Sq.Mtr(v) Tray Int. Size: 300 (H) x 2450(W) x 500 (D) in mm(vi) Tray dead weight - 57 Kg (Approx.)(vii) Per tray weight capacity - 300 KgTechnical specification of the system:-(viii) Tray Quantity : 32 Nos.(ix) Usable net load - 9.6 ton(x) Storage surface area per system - 39.2 sq mtr(xi) Door - Automatic(xii) Power consumption - 3.7 KW(xiii) Power supply - 440V, 50/60 Hz, 3 Phase(xiv) Motor 3 Phase 1440 RPM - Seimens make or equivalent(xv) Chain - Diamond makeor equivalent(xvi) Bearing - SKF/NTN make or equivalent(xvii) External cladding - Epoxy powder coatedSafety Features:1. Photo curtain at access port, 2. Motor Protection relays, 3. Limit switch at door, 4. Single phase preventer,5. Switch mode power supply, 6. 15 Min battery backup for PLC, 7. Noise less than 60db, 8. Emergency stop various safety alertsNote: The system and software provided under this item shall be of same make as for item 13.069 or a compatible system and software as recommended by the chosen manufacturer of ASR system. This system shall be integrated with ASR system. 84 Supply, installation and testing of Car Traffic Boom Barrier 6 mtr suitable to working on power supply 230 Volt, 50 Hz, 24V DC electric motor, adjustable with CAMS, operating ambient temperature from -20 to +55 Degree Celsius, uses cycle 2000/Day, air cooling, type of beam is rectangular with skirt, effective torque 280-290 Nm open/close time 2 to 4 Sec complete all as specified and as directed by Engineer-in- charge.Make: FAAC/Parkilo/Skidata/BFT 85 EXTERNAL WATER SUPPLYSupply and fix Foot valve conforming to IS,100 mm dia complete all as specified and directed. 86 Supply and fix Cast iron air release valve with 100 mm bore and two outlets as per IS:14845 complete all as specified and directed. 87 Supply, installing, testing and commissioning of electrically driven horizontal Centrifugal Pump set 9.0 LPS at 50 Meter Head as per specification, motor TEFC type, 2880 rpm, 415 V, 50 Hz, 3 phase, class F insulation, IP 55 protection, starting on suitable Star Delta starter. The pump shall be horizontal, end suction, top discharge. The pump shall have cast iron casing, cast iron/bronze impeller (as per manufacturer), carbon steel shaft with common base frame (fabricated mild steel channel frame or cast iron type) placed on RCC (1:2:4) including foundation, bolts, nuts etc. complete with antivibrator pad as required capable of discharging not less than 550 LPM at 45 mtr head inclusive of suitable rated three phase starter as recommended by the manufacturer, PVC insulated copper cable connection from starter to the motor terminals all as specified and directed by the Engineer-in-charge.(01 No. Working + 01 No Stand By)Make:- Kirloskar Brothers/Crompton or equivalent. 88 Supply, install, test and commissioning of LT Panel, indoor type, powder coated, 2.0 mm thick CRCA Sheet, CPRI approved having, IP 43, MS angle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with Horizontal copper bus bar for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 2.0 mm thick CRCA Sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables. Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, track resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. andcomprising as under: LT Panel for Pump House. The LT Panel comprising of the following:- 89 Incoming:-MCCB, thermal magnetic release, 4 pole, 415 Volts, 100 Amps, breaking capacity 36 KA- 01 No. Ics =100% IcuMetering Unit:- (a) R Y B Indications (LED Type)- 01 sets(b) Digital Multi function meter - 01 No.(c) CTs - 100/5A, CL-1, 15 VA - 01 set(d) Horizontal Aluminium busbar for 3 phase, 440 volts, 50Hz, 4 wire system of rating 350 Amps for phase and 350 amp for the neutral barOutgoing:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 63 Amps, breaking capacity 16 KA- 02 No. Ics =100% Icu -2 nos.(b) MCB, TPN 40 Amp, 415 Volt, C Curve - 02 Nos.(c) Star Delta starter 12.5 HP, 3 Phase, 415 Volt- 02 Nos.(d ) Digital ammeter - 2nos.(e) Single Phase Preventer - 2 nos. 90 M & L Valve chamber of internal size 0.90m X 0.90m X 0.90m (internal dimensions) including excavation of earth work in any type of soil, 150mm thick PCC in 1:4:8 type D2 foundation, brick work in CM 1:6, 15 mm thick rendering in CM 1:4 to internal surfaces and external surfaces upto 150mm depth below GL, PCC 1:3:6 type C1 as in coping, cover with two Nos. of hinges and one No. handle made out of MS round bar 10mm dia with necessary locking arrangement including painting to the steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer complete all as shown on drg and as specified. Note:- The quoted rate shall include all earthwork and connected items. 91 M & L Earthing complete with Galvanized steel earth plate electrode of size 600mmX600mm, 6.00 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below the normal ground level with top edge of the plate not less than 1.5m below normal GL and connected to galvanized iron strip of size 32 x 6 mm size by means of bolts, nuts, check nuts and washers of galvanized iron steel all as shown in Electrical Plate No. 3 connecting to earthing test point, including necessary earth work in any type of soil, PCC earth chamber made in PCC 1:3:6 type C1 (using 20mm graded aggregate), common salt, charcoal, CI funnel, earth pit cover in RCC 1:2:4 type B1 (using 20mm graded aggregates), with 8mm CTD bars @ 100mm c/c in both ways, including necessary form work complete including necessary test on completion all as specified and as directed. 92 EXTERNAL ELECTRIFICATIONM & L for HT/LT MS cable route indicator, engraved the description on the disc not less than 6 dia welded with 40x6xmm MS strip of approx length 90 cm duly painted on the steel parts as per colour code and provision of PCC 1:4:8 type D-2 using 40 mm grade stone aggregate of not less than 0.05 cum in each at base under the ground including necessary earth work and formwork complete all as specified and directed.Note: HT route indicator shall be painted as under:-(i) For HT 11 KV cables - “BROWN”(ii) For LT cables - “BLUE” 93 Supply and fix compact air insulated bus bar trunking system with copper busbar 1600 Amps, 50 KA breaking capacity, IP54 protection, bus duct 1600 A, 415 Volt, capacity sandwich type, Set RYBN complete with accessories such as flange ends, vertical bends, supporting brackets etc from transformer to LT panel board complete all as specified and directed. 94 Supply, install, testing and commissioning of Distribution transformer step-down Level 2 (Previously EE Level 3 before Amendment No 4 to IS 1180), 11KV0.433KV, Three Phase complying withIS: 1180/IEC-76(Part-1) 2014 with latest amendments, indoortype double copper wound suitable for 50 Hz system of capacity 800 KVA, oil immersed naturally cooled delta connected on HT side and Star connected on LT side, Vector Group Dyn11, provided with OFF load tap changer to vary secondary voltage from -7.5% to + 7.5 % in step of 2.5 %.Losses should be confined to the limits specified as follows: maximum allowable losses atfull load (100 %) & Half Load (50 %) shall not be exceeded 5838 watts & 2147 Wattsrespectively as per GRlHA RATING, Percentage Impedance: 4.5%. Losses and Impedance are subjected to tolerance as specified in IS 1180. The transformers should be supplied with first filling of oil confirming to IS 335. The transformer should have both side cable end box with neutral brought out complete all as directed by Engineer - in -Charge, and installation of transformer shall be carried out as per IS-10028and comprising with the following standard fittings/Technical specifications:-(a) Lifting lug for transformer and tank.(b) Earthing terminal rating and diagram plate.(c) Air release device.(d) Oil filling inlet pipe with plug.(e) Drain outlet pipe with brass gate valve.(f) Conservator tank with oil level indicator(g) Silica jel breather(j) First fill of oil upto level including conservator tank with fresh new oil conforming to IS335.(k) Type of connection Delta/Star(l) Type of cooling: Oil and Natural Air.(m) Vector group: DYN 11.(n) Temperature rise over an ambient of 50 °C maximum.(o) Cable end box on both side for HT/LT cables of suitable size.(p) Provision of thermometer with pocket.(q) Provision of oil and winding temperature gauge. 95 Supply, install, test and commissioning of LT Panel, Indoor type, powder coated, 2.00 mm thick CRCA Sheet, CPRI approved having, IP 43, MSangle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply,bus bar chamber with Horizontal copper bus bar for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air.The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 1.6 mm thick CRCA Sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables. Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, track resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. andcomprising as under: The LT Panel comprising of the following:- Main LT PanelHorizontal copper busbar for 3 phase, 440 volts, 50 Hz, 4 wire system of rating 1600 Amps for phases and 1600 Amps for Neutral. 96 Incoming:-Incomer:-ACB 4 Pole, 415 V, 50 KA with Thermal Magnetic Release (Manual Draw out type) of capacity 1250 AmpMetering Unit:- (a) R Y B Indications (LED Type)- 1 sets(b) Digital Multi function meter - 01 No.(c) CTs - 1600/5A, CL-1,15 VA - 1 setOutgoing:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 630 Amps, Ics =100% Icu, breaking capacity 35 KA, Ics =100% Icu- 02 No. (For DG AMF Panel & Spare)(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 400 Amps, Ics =100% Icu breaking capacity 36 KA- 02 No. (for APFC Panel & FPB 2 Near bulk Store) (c) MCCB, thermal magnetic release, 4 pole, 415 Volts, 320/315 Amps, Ics =100% Icu breaking capacity 36 KA- 01 No. (for FPB 1 Near Adm Block) (d) MCCB, thermal magnetic release, 4 pole, 415 Volts, 200 Amps, Ics =100% Icu breaking capacity 36 KA- 01 No. (for Existing Load)(e) MCCB, thermal magnetic release, 4 pole, 415 Volts,125 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for FPB 3 Near Auction Disposal Store)(f) MCCB, thermal magnetic release, 4 pole, 415 Volts, 32 Amps, Ics =100% Icu breaking capacity 25 KA- 03 No. (for MT Complex, Watch tower no 2, Guard room)(g) Digital Ammeter with suitable CT for each outgoing 97 Supply, install, test and commissioning of LT Panel, outdoor type, powder coated, 3.00 mm thick CRCA sheet, CPRI approved having, IP 54, MS angle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply,bus bar chamber with Horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 2 mm thick CRCA sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables. Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, crack resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. Feeder Panel No.1 (Near Admn bldg) 98 Horizontal Aluminium busbar for 3 phase, 440 volts, 50Hz, 4 wire system of rating 600 Amps for phases and 600 Amps for Neutral.Incoming:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 400 Amps, breaking capacity 36 KA - 01 No. Ics =100% IcuMetering Unit:- (a) R Y B Indications (LED Type) - 1 sets(b) Digital Multi function meter - 01 No.(c) CTs - 600/5A, CL-1,15 VA - 1 setOutgoing:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 200 Amps, Ics =100% Icu breaking capacity 36 KA- 02 No. (for 2nd floor & spare)(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 160 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for 1st floor)(c) MCCB, thermal magnetic release, 4 pole, 415 Volts, 63 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for G floor)( d) Digital Ammeter with suitable CT for each outgoing 99 Supply, install, test and commissioning of LT Panel, outdoor type, powder coated, 3.00 mm thick CRCA sheet, CPRI approved having, IP 54, MSangle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply,bus bar chamber with Horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air.The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 2 mm thick CRCA sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables.Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, crack resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. Feeder Panel No.2 (Near Bulk Store) Horizontal Aluminium busbar for 3 phase,440 volts, 50Hz, 4 wire system of rating 600 Amps for phases and 600 Amps for Neutral. 100 Incoming:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 400 Amps, breaking capacity 36 KA - 01 No. Ics =100% IcuMetering Unit:- (a) R Y B Indications (LED Type)- 1 sets(b) Digital Multi function meter - 01 No.(c) CTs - 600/5A, CL-1,15 VA - 1 setOutgoing:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 200 Amps, Ics =100% Icu breaking capacity 36 KA- 02 No. (for Equipment Load & spare)(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 125 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for Bulk Store)(c) MCCB, thermal magnetic release, 4 pole, 415 Volts, 32 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for Watch Tower No. 1)( d) Digital Ammeter with suitable CT for each outgoing 101 Supply, install, test and commissioning of LT Panel, outdoor type, powder coated, 3.00 mm thick CRCA sheet, CPRI approved having, IP 54, MSangle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply,bus bar chamber with Horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 2 mm thick CRCA sheet, duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables.Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, crack resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. Feeder Panel No.3 (Near Auction Disposal Store) 102 Horizontal Aluminium busbar for 3 phase, 440 volts, 50Hz, 4 wire system of rating 200 Amps for phases and 200 Amps for Neutral.Incoming:-(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 125 Amps, breaking capacity 25 KA- 01 No. Ics =100% IcuMetering Unit:- (a) R Y B Indications (LED Type) - 1 sets(b) Digital Multi function meter - 01 No.(c) CTs - 200/5A, CL-1,15 VA - 01 setOutgoing:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 100 Amps, Ics =100% Icu breaking capacity 25 KA- 02 No. (for Store Dispatch Complex & Spare)(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 32 Amps, Ics =100% Icu breaking capacity 25 KA- 03 No. (for Pol store, Auction disposal store, Covered Hard Standing)(c) Digital Ammeter with suitable CT for each outgoing 103 Supply and fixing poly carbonate street light junction boxes IP 66/67 Weather proof suitable for outdoor installation having minimumsize255 x 355 x 122 including suitableCable connecting Terminals, Cable lugs, including provn of one No. MCB SP 6 Amps for operating the street light fittings, Suitable Cable Glands as per site requirement, all as directed by the Engineer-in-Charge. 104 S & F Street light bracket made out of GI tubing 32/40 mm dia, light grade of length1.2 mtr long bend to shape suitable for security light fitting with necessary MS clamp-02 Nos with one coat of anti corrosive primer and two coats of aluminium paint including nut, bolt, washers and 3 core FRLSinsulated sheathed, multistranded copper conductor of size 1.5 sqmm for phase and neutral and 1.5 sq mm for earthing drawn throughthe poles for connection from junction box to light fitting complete etc all as specified.Note: Phase should be Red/Yellow/Blue, neutral should be black and earthing wire should be green in colour. Two runs of cable for phase and neutral and one run of cable for earth will be measured and paid as one unit length. 105 Supply and fixing of LED flood light, 200W, watt 230 V, AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp and made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP protection incl system efficiency >110/120LPW 10KV SPD included Energy saving, environmental friendly and general purpose lighting complete all as specified and directed Engineer-in-Charge. Make : Make : Crompton/Philips/Wipro 106 Supply and fix High Mast Panel outdoor type, suitable to take load up to 6 KW, Conforms to IS/IEC 60947-4-1, Provided with Protection Degree IP 54, Extended wide band (150 Vac - 300 Vac) coil, FRLS (Fire retardant low smoke) Internal wiring, In-built Short-Circuit Protection, Class H Insulation, 3 Phase 415 Volts AC with the following accessories:Phase : 3 Phase, 415 VoltsMax Load Capacity : 6 KWTimer type: AstronomicalContactor Rating : 32 A TPMCB Rating : 63 A TPNMake : Crompton/ Philips/Wipro 107 Supply and laying DWC (Double wall Corrugated) duct pipe outer dia 63 mm and inner dia 50 mmconforming IS 16205 (Part 24 ) for protection ofelectric cable complete all as specified and directed. ( for 10 sqmm St light cable & 16 Sqmm cable) 108 AVIATION OBSTRUCTION LIGHTSupply and fix aviation obstruction light integral aviation light comprising of aluminium housing with polycarbonate enclosure, 240 volt with timer switch and one No.10 A, MCB, SPN 230 V with fixed enclosure complete all as specified and directed by Engineer-in-charge.Make:- Bajaj cat No BGAV 302 LED or equivalent in Philips/Crompton/Surya 109 INCINERATORSupply, fixing and testing of Solid waste Electric Incinerator, single chamber type having a combustion chamber supported with electric coil for generating sufficient heat to burn 100Kg/hr solid waste, retains and re-burns the exhaust gases for minimum of 2 seconds at 850°C, Stainless steel stack for longevity, fitted with a Velocity Cowl as standard, Chamber designed for maximum air flow and circulation which in turn improves efficiency and total burn time, easy to open and close loading door, designed to increase operator safety, steel cladding to reduce risk of infection and increase longevity of system with working temperature not less 450 degree Celsius mounted on foundation as recommended by OEM including electrical control panel with suitable size MCCB, relays & contactor recommended by OEM complete all as complete all as specified and directed.Note:(a) The electrical works including electrical LT panel, internal wiring of the LT panel, suitable size copper wires from panel to Solid waste Electric Incinerator as recommended by OEM to operate the Solid waste Electric Incinerator of capacity 100 Kg/Hr to make Solid waste Electric Incinerator operational is deemed to be included in the rate quoted. (b) All Electrical works shall be carried out as per relevant BIS/lS equivalent standard norms only and also in accordance with the latest edition of the Indian Electricity Act / rules formed there under and as amended from time to time.(c) Any other works (mechanical, electrical & Civil) connected to installation, testing & functional requirement of Solid waste Electric Incinerator of capacity 100 Kg/Hr all as mentioned above and which is not mentioned or included in this Schedule but required at site necessary shall be carried out by the contractor and quoted rate shall deemed to included for the same.(d) Foundation/Plinth/Base: shall be provided as per manufactures recommendations, however minimum 0.5m space should be available all around the Solid waste Electric Incinerator and height of plinth shall not be less than 0.5 M 110 Supply & fixing MCCB, thermal magnetic release, 4 pole, 415 Volts, 200 Amps, breaking capacity 36 KA- 01 No.Ics =100% Icu with Sheet metal enclosures fixed properly at directed location and connecting/testing complete all as directed. 111 ELECTRIC SIRENSupply and fixing Sirens Electronic type Horizontal Double Mounting Three Phase 400/440V, 2800 RPM 50 C/s Flame Proof, audible range 3.5 Km, 2 HP, continuous normal operation for at least 50 minutes with on/off system complete all as specified and directed. 112 Supply and fix advance Sirens controller Electronic type suitable to operate on 3 phase, 415 volt AC 50 Hzcomplete all as specified and directed. 113 Supply & fixing MCCB, thermal magnetic release, 4 pole, 415 Volts, 63 Amps, breaking capacity 25 KA- 01 No.Ics =100% Icu with Sheet metal enclosures fixed properly at directed location and connecting/testing complete all as directed. 114 SOLAR POWER PLANTDesign, supply, installation testing and commissioning of roof top solar photovoltaic power plant (ON-GRID) on roof top of existing bldg of capacity 150 KWp, power evacuation at 415 Volt 3 phase system all as per guidelines/norms issued by MNRE & Indian Metrological Deptt approved Solar Radiation Data viz Direct Normal Irradiance, Global Horizontal radiance etc complete comprising with the following Solar Photo Voltaic Plant.(a) Design, supply, installation, testing and commissioning of Solar PV Modules capable of generating 150 KWp (AC) electricity at 415 Volt 3 phase system. These Solar PV Modules of 540 watt PERC with a modular efficiency of 17-19.84% as per IEC and MNRE standard or as per approved design parameters with Poly/Multi Crystalline Silicon Solar cells of minimum wattage of 540 watt with minimum 144 cells & efficiency not less than 17 -19.84%, conforming to IEC 61215, IEC 61730, IEC 61701. Solar PV Module should be of approved Indian Brand only and Qualify under the Domestic Content requirement (DCR) norms of NVVN/SECI and testing requirement fixed by MNRE. The PV modules shall be warranted for a period of minimum 25 years, Solar PV modules used in system shall be warranted for their output peak watt capacity, which should not be less than 90% at the end of Ten years and 80% at the end of Twenty Five years. Each Solar PV Module must use RF identification tag. The following information must be mentioned in the RFID used in each module:Name of manufacture of PV module, Name of manufacturer of Solar cell, Month & year of manufacturer (for solar cell and module), Country of origin (lt is mandatory to use cells and modules manufactured in India). I-V curve of the module, Wattage, LM, V-M, & FF for the module, Unique Serial No & Model No of the module, Date & year of IEC PV qualification certificate, Name of the test lab issued IEC certificate. The PV modules used in the solar power projects must qualify to the latest edition of the following International Electro technical Commission (IEC) P module qualification test or equivalent BIS Standards. The PV module must be tested and approved by one of the IEC authorized test centres. 115 (b) Material and labour for Module Mounting structure (MMS) fabricated from hot dip galvansied iron section of suitable size with specified tilt angle according to site requirement & optimum angle to achieve maximum benefit of solar energy and suitable to withstand 180 Kmph wind speed all as per approved design parameters as per MNRE standards and to match with the existing site conditions. Necessary roof treatment to avoid any seepage in future shall be done by the Contractor and the amount included in the rate quoted. The roof tiles shall be dismantled and refixed back in original position. Structure shall be built with brick masonry basement of adequate size as per direction at site including all necessary civil work required for the foundation.(c) Supply, laying & Testing of DC cable minimum size 4/6sq mm multi stranded copper conductor, conforming to relevant IS, weather proof UV resistant with operating temperature up to 120 degrees, minimum rated voltage 1100 volt for inter connection of SPV Modules to array junction box including suitable size of cable lugs, male & female MC4 connectors & joints etc.(d) Supply, installation test and commissioning of protection devices MCCB 400 A, isolator and three phase 4 wire LT energy meter, array junction boxes having rating 150 KWp with over voltage protection and surge protection.(e) Supply, installation, test and commissioning of Grid tie Solar Power conditioning unit / inverter of minimum capacity 150 KWp(DC to AC 415 V in Three phase system) all as per approved design parameters & capable of generating output voltage 415 V AC at rated load condition with efficiency not less than 98 %, conforming to IEC 600682-2 NDE standards with power reduction, LVRT with protections for anti-islanding, Ground fault monitoring, Grid Monitoring, AC & DC Over voltage and under voltage protection, AC & DC short circuit lover current protection and DC reverse polarity protection, graphic display etc. all as specified and as directed.(f) Material and labour for Earthing for Lightning protection for SPV modules etc as per IE rule, MNRE guide line & BIS all as per approved plan complete with galvanised earth plate electrode 600x600x6 mm thick buried directly in ground vertically (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected to and including Gl strip 32x6mm size protected with Gl medium grade pipe 40mm dia for earth electrode up to test point by means of GI nuts, bolts, check nuts and washers including earth work excavation, PCC (1:3:6) type Cl pit and RCC cover ( 1:2:4) type Bl and funnel, with necessary charcoal, salt etc complete. 116 (g) Supply and fixing aluminium strip of size 25 x 3mm thick for roof / down conductor fixed on insulators/ saddles of suitable size for SPV modules lightning protection upto interconnection between Roof top LA to Ground Earthing system. (h) AC Cable: Supply and laying of 150 Sqmm LT XLPE insulated, screened PVC bedded, sheathed with multi-stranded aluminium conductor armoured with galvanised steel wire 1100 volts grade heavy duty conforming to IS 150 Sqmm x 3.5Core as per site requirement.Note (i) :-(a) Before quoting the bid, Contractor or his authorised Engineer/consultant must visit the proposed site to study the site condition.(b) Before commencement of work, contractor shall submit drawings & lay out plan with scale including required qty to Accepting Officer for approval.Note(ii):-(a) The mechanical structures, electrical works and overall workmanship of the Grid solar power plant must be warrented for a minimum of 5 years.(b) All Mechanical, Electrical works shall be carried out as per relevant BIS/lS equivalent standard norms only and also in accordance with the latest edition of the Indian Electricity Act / rules formed thereunder and as amended from time to time.(c) Any other works (mechanical, electrical & Civil) connected to installation, testing & functional requirement of solar photovoltaic power plant of capacity 150 KWp (AC) all as mentioned above and which is not mentioned or included in this Schedule A but required at site necessary shall be carried out by the contractor and quoted rate shall deemed to included for the same(d) Contractor shall provide adequate Spares/items required for minimum period of 1 year maintenance including DC & AC items under scope of work.Note (iii) : Design report shall be submitted before execution of Work at site by the contractor toGE for his scrutiny / comments and futher submitted to AO for obtaining approval. 117 DG SETSupplying, installing, testing and commissioning, factory assembled silentDiesel Engine driven generator set, fully wired alternator AC to give an out put of 400 KVA continuously rating at a power factor 0.8 lagging, 3 phase 4 wire, 415 volts 50 Hzsupply, 1500 RPM, directly coupled with diesel engine liquid cooled mounted on common base frame complete with floor mounting fuel tank (service tank) of adequate capacity with fuel line & accessories, PCC foundation work as per manufacturers instructions, vibration damper pads, control panel & other accessories etc and comprising of following.(a)Diesel Engine: Liquid cooled turbo charged with after cooler to deliver suitable BHP at 1500 RPM under NTP conditions of BS 5514 and conforming to IS 10001/ 10002, DIN 6271 & ISO 3046 with an overload capacity of 10% for one hour in any 12 hours continuous operation with the following accessories:. Diesel engine of rated speed at full load electric start developingwithsystem with radiator and including electronic governor control of class A1, engine control panel, lub oil pump, water pump, fuel tank, exhaust pipe with silencer and suitable for electric start with batteries ofadequate capacity and suitable for alternator of specified capacity complete with fly wheel direct/flexible coupling and coupling guard complete.(a) Radiator with blower fan or heat exchanger with guard.(b) Pipe coupling for engine cooling system piping.(c ) Corrosion inhibitor coolant(d) Paper element filters(i) Fuel filter(ii) Lube oil filter(iii) By pass(e) Fly wheel housing and fly wheel to suit alternator.(f) Engine bearing mechanism in fly wheel housing.(g) Shut off coil with safeties for LLOP/HWT/over speed.(h) Dry type air cleaners and vacuum indicators.(j) Residential silencers.(k) Stainless steel exhaust flexible bellows. 118 (l) Motor driven priming pump.(m) Battery charging alternator.(n) Exhaust piping made out of STIC C class, MS pipe inclusive of all accessories and hardware, necessary supports scaffolding as per manufacturers recommendations to sustain back pressure with rain cap.(o) Mineral wool insulation 2 inch thick suitable for 400 degree Celsius temperature cladded with aluminium sheet o30 gauge for the entire length of exhaust pipe.(p) First fill of oil, coolant and diesel during commissioning and 12 hours testing.(q) Interconnecting copper cabling of adequate capacity batteries control.(r ) Fuel pipe class STIC 1 /1.5 /2 dia - 01 lot(s) Self starter 12 volts DC.(t) Electric operated electronic governor.(u) Fuel injection pump.(v) No of cylinders - 12 No VEE(w) Electronic instrument panel, complete with all accessories as per manufacturers specifications displaying the following:-(i) 12vx2 nos -24V Battery. (ii) Water temperature.(iii) lubricating oil pressure.(iv) Engine speed -1500Rpm(v) Engine hours(vi) Frequency.(vii) Voltage.(w) Safety control (Trip and indication).(i) High water temperature(ii) Low lube oil temperature(iii) Overspeed stop 119 (x) Base frame: Sturdy, fabricated welded construction, channel iron base frame (duly painted) for mounting engine and alternator as per manufacturers design alonwith AVM pads.(y) Battery:-24 volts(2x12v Battery) DC, 180AH, maintenance free battery conforming to IS:14257 with leads & terminals (Make- Excide/Amron).(z) Fuel tank:12 hrs. full load diesel storage capacity fuel tank with mounting brackets factory made of 5mm thick HR/MS sheet with level indicator fuel inlet, fuel outlet, air vent, drain plug, in let arrangement for diesel filling fro exterior canopy (without opening its panel) etc complete all as specified and directed.(aa) Isolator panel with 250 amp MCCB(ab) Auto logic panel for automatic stat(b) Alternator: Alternator suitable rated for 400 KVA, 0.8 pf , 415 volts, 3 phase, 4 wire, 50 Hz at 1500 RPM, self excited and self regulated with AVR brushless, screen protected, drip proof , insulation class-H, IP -23, voltage regulationgrade - VG 3 self ventilated and conforming to BS: 5000 / IS: 4722 suitable for engine as mentioned here-in before, conformig to IS: 13364(part-1)Make: KOEL GREEN / stampford/crompten/kirloskar/Greaves(c) Acoustic Enclosure:- M & L for acoustic enclosure for the above 400 KVA DG set to reduce noise level to 75 dB measured at 1.0 meter distance for audible frequencies as per guide of Central Pollution Control Board andmanufacturers specification and comprising of following from authorised GOEMs of Gen Set manufacturers specified :-(i) Sound insulation : 100mm thick Rock wool (Density 64 Kg/Cum).(ii) Outer body : 1.6mm thick CRCA(iii) Door : 1.6mm thick CRCA(iv) Base frame : ISMC 300(v) Inside illumination : 1 No.- 1 x 18 watt LED fitting of make Phillips/ Bajaj/ Crompton.(d) AMF Control panel:- Factory fabricated cubicle type, free standing, floor mounted, indoor type, IP-43, AMF control panel, provided with removable rear panels & hinged front panel for easy accessibility, fabricated out of not less than 2.0mm thick CRCA sheet including two coats of powder coated paint over a coat of red oxide primer etc and comprising of following: 120 (e) AMF control circuit with 4 pole MCCB 630 Amps - 2 nos, with ultimate breaking capacity Icu-50 KA at 415 volts and microprocessor release conforming to IEC 60947 Part-I with breaking capacity Ics=Icu at 415 volts , thermal overload setting 70% to 100%, short circuit setting 5 to 10 times-02 Nos. for main supply & DG set supply with HRC back up fuse complete with all DC control relays/ Line voltage monitor (LVM) as per OEM specifications incorporating motorised stored energy operating Engine start, stop, three attempt starting facility and failure to start etc.(f) Digital load manager : Three phase 4 wire indicating V,I,PF, KVA, KW, F of Enercon make with serial communication port model No.EM6400 with class 1.0 accuracy meter or equivalent make suitable rating of CT per phase- one No.(iii) Indication lamp R, Y, B with 3 Nos. of 2A HRC fuses-10 sets.(iv) Bottom gland plate for incoming and outgoing cables.(v) Circuit diagram plate.Note :- DG set should be as per CPCB -4 latest norm wef 01 July 2023 of National Clean Air programme (NACP) Act 1981. 121 Supply, install, test and commissioning of LT Panel, Indoor type, powder coated, 2.00 mm thick CRCA Sheet, CPRI approved having, IP 43, MSangle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply,bus bar chamber with Horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natuaral flow of air.The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 1.6 mm thick CRCA Sheat duly compartmentalised for each control gear with louvers and air vent gasket for natuaral flow of air and suiatable provision to accomodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables.Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, track resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. Feeder Panel No.1 (DG Panel ) 122 Incoming:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 630 Amps, breaking capacity 36 KA - 01 No. Ics =100% IcuMetering Unit:- (a) R Y B Indications (LED Type) - 1 sets(b) Digital Multi function meter - 01 No.(c) CTs - 800/5A, CL-1,15 VA - 1 setOutgoing:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 400 Amps, Ics =100% Icu breaking capacity 36 KA- 02 No. (for Package AC Bulk Store & spare)(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 160 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for Pump House & Fire Pump)(c) MCCB, thermal magnetic release, 4 pole, 415 Volts, 80 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for Incianator)(d) MCCB, thermal magnetic release, 4 pole, 415 Volts, 32 Amps, Ics =100% Icu breaking capacity 25 KA- 07 No. (for Terrace pump 1, Terrace pump 2, Power House, High mast 1, High mast 2, Street Light)(e) Digital Ammeter with suitable CT for each outgoing(f) Astro Time switch for 3 phase 20A- 1 No(g) 3 Phase Power contactor 20 amps, with 230 coil 123 SEWAGE DISPOSALM & L for laying of DWCPE sewage pipes line 200 mmdia borepipe sftiffnessclass SN 8 includingsealing of joints fittings etc complete with collers complte all as spcified and directed 124 M & L for laying of DWCPE sewage pipes line 150 mmdia borepipe sftiffnessclass SN 8 includingsealing of joints fittings etc complete with collers complte all as spcified and directed 125 COMPOUND WALLS & F Concertina Coil of 600/700 mm outer dia made out of 2.60 mm dia spring steel wire dipped in corrosion preventive fluid (rusilo 901) of castrol make each coil having min 50 turns (circles) covering 6 m and an average weight not less than 8.57 Kg (plus or minus 5 %) incl handle and spike at both ends of coil erected in position on top of mild steel angle by fixing with 1.70 mm GI wire for securing, coil with fish hook bars, incl necessary welding to MS Sections etc all as specified and directed. 126 GREEN BUILDING NORMS(GRIHA CONCEPT)Supply and Install Organic Waste Converter fully automatic having capacity 50Kg/day, having internal tank made of high quality stainless steel while external panels are powder coated for enhanced product life with necessary electric control panel, cabling necessary civil works for installing machine etc with following requirements:-Type of machine: Fulley automatic in-vessel composterComposting method: 24 Hrs. Micro-organisms-based compostingmachine Type of microganism used: Heat resistant thermophilic bacteria Final Output: Dry organic Soil conditioner/Soil supplementsCycle time: 24Hrs Volume reduction in 24Hrs: 80-85% Internal tank: Stainless steel type Main agitator Shaft: Stainless steel type Input voltage: 415VSpecial features: VFD as standard across all models, Touchscreen standards Daily waste processing: 150Kgs Rated capacity: 7KWPower consumption (KWH par cycle): 13-15Length: 1650, Width: 850,Height: 1455 127 Supply, installation, testing and commissioning Three phase energy meter with the following specifications: Microprocessor based three phase, smart electricity meter, equipped with a bi-directional cellular (NB-IoT) communication that allows it to interact with the head end system (HES) for data collection and configuration with adequate security including electronic static pre paid cum postpaid energy meter rating 415 Volts, 50 Hz of range 10-100 Amps, complying to IS16444:2015 (reaffrimed 2020) and conforming to IS 3779 with LED display and parameters like Voltage, Current, Frequency, Power, Power factor, KWH/KVA, default in built dual source, inbuilt long range (LORAWAN) Communication suitable for outdoor LoRa data accumulator and also compatible for Prepaid and Postpaid online energy monitoring billing system with disconnection /reconnection through remote software / data export to ERP complete with 5 Years warranty.Note:(a) The contractor would be responsible for removing the existing meter, noting down the reading and depositing it with the MES AGE E/M store complete all as specified & directed.(b) The Energy Meter to be capable of running in both prepaid and postpaid mode.(c) The meters to carry 5 year warranty. (for entire system) 128 Supplying, Fixing, Commissioning and testing of configuration of cloud Hosted multi user web based software with following modules:(i) Head End System (HES): to acquire meter data automatically from DCU sand monitor parameters acquired from meters.(ii) Meter Data Management ModuleThe meter data management module would be responsible for collecting the data from the data concentrator and make the data available to the billing system. The system would support offline meter(a) 30 min instantaneous data from all the meters for seven parameters Cumulative Energy. Cumulative Apparent Energy (as applicable), Power, Current, Voltage, Power Factor and Frequency(b) Monthly billing survey data for cumulative energy and max demand(iii) Billing Module: The billing module would collect the data from the meter data management module, calculate the energy consumption, calculate billing determinant and make energy data/billing data available to admin and end users. The billing module would include functionalities for tariff setup, bill format setup, bill adjustment, occupation billing and vacation billing. It would allow postpaid and prepaid functionality as required.(iv) Occupation and Vacation Module: The system would support occupation/vacation based on the unit catagories. The system would support automatic data capture on occupation and vacation events.(v) Website: There would be a dedicated website forAGE/GE and BSO team to view all the data and information alongwith customer portal for use of customer. The designated users in MES would have the admin access to the application. The MES Staff would also have the access to the key information on mobile App (AndroiandiOS based) for admin use complete all as specified and directed.(vi) Customer Module: The system would include a customer portal for the resident/occupants to login and view their own energy /billing data and recharge facility. There shall be consumer App (Android and iOS based) also to log in and view their own energy/billing data and recharge facility.(vii) Communication Module :The system would provide communication of energy data and bills via print, email and sms methods. 129 (viii) Meter Master Data: The system would support meter data repository. The system would support meter replacement process.(ix) Excel Export: the system would support export of metering and billing data in excel and pdf format.(x) Energy Accounting module: The system would include features of energy accounting, the system would to able to account for total energy block wise, facility wise and would also allow calculations of the unaccounted energy in case total energy meter is also available.(xi) Prepayment/Recharging Facility:The system should periodically monitor the energy consumption of prepaid consumers and decrease the available credit based on the consumption. The system should allow online/digital recharging through consumer App (Androidand iOSbased) and Web portal. The configuration and necessary arrangement for payment gateway and E-MRO facility shall be deemed to be included in the quoted rate. The system should sendconnect/disconnect command on the basis of available credit.Low credit alarm: The system will give an alarm over the consumer App and SMS to the registered mobile number in case the credit in the meter goes down be low apredefined limit.Emergency credit: The meter will work even when the credit falls down to zero to prevent disconnection. This limit shall be configurable. The system should support happy hours inorder to prevent disconnection in non working hours and on holidays. The Happy hours should be configurable complete all as specified and directed. 130 Supply, Installation, Testing and Commissioning of DCUs/Gateways and the arrangement of Sim cards or Internet to enable reliable medium for two-way communication between Smart Meter & HES. The data acquisition (Push/Pull) frequency shall be, configurable. It shall push events such as tamper, power off etc. to HES immediately on occurrence/receipt from meters. It shall have provision for the cellular, WiFi and Ethernet communication for the backhaul to HES. It shall be capable to handle data of minimum 1000 Nos. of any type of smart meter (1ph/3ph).It shall be able to communicate with the nearest meters at a distance of at least 500 m, depending on topographical features. Communication of the nearest meters with other meters shall be established through appropriate mesh formation. RF Mesh shall support self-forming and self-healing features. The equipment shall be weather proof and dust proof (minimum rating: IP54 for indoor and IP65 for outdoor installation). It shall have rechargeable battery with backup for 1(one) hour for normal meter reading, to push tamper event, carry out on demand reading, etc complete all as specified and directed. 131 Hosting GPRS (4G) charges for Gateway for five years from the date of completion F Including 2 years waranty and 2 years Maintinance after warranty) Make:-Airtel/Jio/Vodafone 132 Supply and installation of digital Water flow meter 50mm suitable for domestic and commercial applications complete all as specified and directed. 133 Supply and installation of digital Water flow meter 40mm suitable for domestic and commercial applications complete all as specified and directed. 134 ARBORICULTUREM & L for excavation of pits size 30cm x 30cm x 30cm in loose soil and filling the pit with mixture of river sand and approved top soil in the proportion of 1:3 mixed with 30% of cow dung powder, 100gms of bone meal and 100gm of neem cake powder 135 All as per item No 13.121 above but pit size 60cm x 60cm x 60cm 136 Supplying and planting red palm or royal palm healthy sapling having 45cm height and shall have a minimum height of 65cm after 6 months 137 Supplying and planting coconut tree healthy sapling having 75cm height and shall have a minimum 95cm after 6 months. 138 Supplying and planting flower plants(Champa/ hybrid hibiscus/ Hybrid west Indian Jasmine/ Hybrid Plumeria white plant/ Panama yellow plant/ Oleander) healthy sapling having 10cm minimum height and shall have a minimum 25cm to 30cm height after 6 months. 139 Supplying and planting phylanthus healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 140 Supplying and planting bougainvillea colour flower plants healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 141 Supplying and planting song of India flower plants healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 142 Supplying and planting dracaena flower plants healthy sapling having 15cm to 30 cm height and shall have a minimum 60cm height after 6 months. 143 Supply and planting mexican grass including providing manure as directed. 144 PILE FOUNDATIONBoring 450 mm dia piles to any depthin any type of soil/ strata by anyapproved method, complete all as shown on drawings and as specified anddirected.Note:- The quoted rate shall include for mobilization and demobilisation of piling equipment, making approaches to site or point of pile boring if necessary. Nothing extra shall be paid on this account. 145 Boring for bored cast in situ pile 600 mm dia to any depth through any type of soil / strata, using DMC method (Direct Mud Circulation)and getting out & disposal of spoil to any distance outside of MD land , complete all as specified and as directedby the EngineerIn Charge 146 M & L Reinforced cement concrete of grade M-35 design mix (RMC) as per IS-456using 20 mm graded stone aggregate in cast in situ DMC bored pile of any length / any sectionscomplete all as specified and as shown on drg 147 M & L Reinforced cement concrete of grade M-35 design mix (RMC) as per IS-456using 20 mm graded stone aggregate in pile caps / grade beams complete all as specified and as shown on drg 148 Providing TMT bars (CRS/HCRM/CRM) in reinforcement 10 mm dia and over for bored cast in situ piles of any length and any dia all as shown on drgs including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with and including 0.9mm dia MS wire (annealed) or welding so as to secure the bar firmly in position/ required shape complete all as specified and shown on drgs (Fe-500D). 149 Providing TMT bars (CRS/HCRM/CRM) in reinforcement 10 mm dia and over for pile caps and grade beams, cut to length, bent to shape required, hooking ends and binding with and including 0.9mm dia MS wire (annealed) or welding so as to secure the bar firmly in position/ required shape complete all as specified and shown on drgs (Fe-500D). 150 All as per item No 13.136 here-in-before but5mm dia and over upto and including 10mm dia as in helicals for piles and stirrups for grade beams complete all as specified and directed. 151 M & L for providing PCC (1:4:8) type D-2 using 40 mm graded stone aggregate for concrete layer below pile caps foundation complete all as specified and directed. 152 Formwork to sides of pile caps/ grade beams and similar work, rough finished surface of concrete flat all as specified and as directed. 153 M & L for carrying out non destructive integrity test all as per IS 2911 (Part 4) 2013 for 600 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed all as specified and directed. 154 M & L for carrying out Initial Load test (vertical load test) cast in situ piles of 600 mm dia as per IS 2911 (Part 4) 2013 including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note :- Providing and installing test piles shall measured and paid separately) 155 M & L for carrying out Initial (lateral load test) cast in situ piles of 600 mm dia as per IS 2911 (Part 4) 2013including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note :- Providing and installing test piles shall measured and paid separately) 156 M & L for carrying out Initial load test ( pull outtest) of cast in situ piles of 600 mm dia as per IS 2911 (Part 4) 2013including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note :- Providing and installing test piles shall measured and paid separately) 157 M & L for carrying out Routine load Test (Vertical load)all as per IS 2911 (Part 4) 2013 for 600 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed 158 Testing of piles (Initial load test) for 450mm dia cast in situ bored piles all as per IS including removing the testing equipments from the site after testing is completed all asspecified and as directed
Contract Date : 23 Jul, 2025   |   Contract Value : 57.42 Crore
BRR : 8979082 Tender For Electrical Work - &P 2 Fire Fighting Work Fire Pumps And Accessories: Supplying, Installation, Testingand Commissioningof Electric Driven Main Fire Pump Suitablefor Automatic Operationandconsistingoffollowing, Completeinall Respects, As Required :A ) Horizontal Type, Multistage, Centrifugal, Split Casing Pump Of Cast Iron Body & Bronze Impeller With Stainless Steel Shaft, Mechanical Seal Conforming To Is 1520.B ) Suitable Hp Squirrel Cage Induction Motor, Tefc, Synchronousspeed1500rpm, Suitableforoperation On415volts, 3Phase50hz, Acsupplywithip55 Protectionforenclosure, Horizontalfootmountedtype With Class-F Insulation, Conforming To Is-325.C ) Suitable Hp Squirrel Cage Induction Motor, Tefc, Synchronousspeed1500rpm, Suitableforoperation On415volts, 3Phase50hz, Acsupplywithip55 Protectionforenclosure, Horizontalfootmountedtype With Class-F Insulation, Conforming To Is-325.D ) M.S. Fabricated Common Base Plate, Coupling, Coupling Guard, Foundation Bolts Etc. As Required. E ) Suitablecementconcretefoundationdulyplastered With Anti Vibration Pads. F ) 2850 Lpm At 70 M Headnote: * The Head Of The Pump Is Selected In A Manner Soastogivea Minimum 3.5Kgf / Cm 2 Pressureat The Highest / Farthest Point. 3 Supplying, Installation, Testingandcommissioningof Diesel Engine Driven Main Fire Pump Suitable For Automatic Operation And Consisting Of Following, Complete In All Respects, As Required : ( Diesel Driven Pump ) A ) Horizontal Type, Multistage, Centrifugal Pump Of Cast Of Iron Body And Bronze Impeller With Stainless Steel Shaft, Mechanical Seal Conforming To Is 1520.B ) Suitablehp, 1500Rpmwatercooledwithradiator, Diesel Engine Conforming To Relevant Is Standard Completewithautostartingmechanism, 12 / 24Volts Electricstartingequipment, Dieseltank, Exhaustpipe Extended Upto 10 M Outside Pump House Duly Insulated With 50 Mm Thick Glass Wool With 1.0 Mm Thick Aluminium Sheet Cladding, Residential Silencer, Instruments And Protection As Per Standard Specification, Stop Solenoid For Auto Stop In The Event Of Fault With Audio Indications, Painted With Post Office Red Colour Etc. As Required. C ) M.S Fabricated, Common Base Plate, Coupling, Coupling Guard, Foundation Bolts Etc. As Required. D ) Suitablecementconcretefoundationdulyplastered And With Anti Vibration Pads.2850 Lpm At 70 M Headnote: * The Head Of The Pump Is Selected In A Manner Soastogivea Minimum 3.5Kgf / Cm 2 Pressureat The Highest / Farthest Point. 4 Supplying, Installation, Testingandcommissioningof Electricdrivenpressurisationpumpsuitablefor Automaticoperationandconsistingoffollowing, Complete In All Respects, As Required : ( Jockey Pump ) A ) .Horizontaltype, Multistage, Centrifugalpumpofcast Iron Body And Bronze Impeller With Stainless Steel Shaft, Mechanical Seal Conforming To Is : 1520. B ) .Suitablehpsquirellcageinductionmotortefctype Suitableforoperationon415volts, 3Phase50hz Ac Supply With Ip 55 Class Of Protection For Enclosure, Horizontalfootmountedtypewithclass-FInsulation, Conforming To Is : 325. C ) .M.S.Fabricated Common Base Plate, Coupling, Coupling Guard, Foundation Bolts Etc. As Required.D ) .Suitablecementconcretefoundationdulyplastered And With Anti Vibration Pads.180 Lpm At 70 M Head 5 Control Panels: Fabrication, Supply, Insallation Testing & Commissioning Of Electrical Control Panel Of Cubical Construction, Floor Mounted Type, Fabricated Out Of 2Mm Thick Crca Sheet, Compartmentalisedwithhingedlockabledoors, Dustandverminproof, Powdercoatedofapproved Shade After 7 Tank Treatment Process, Cable Alley, Inter-Connection With Suitable Sizecopperconductor Cable / Solidcopper Strip, Havingswitchgears And Accessories, Mountings And Internal Wiring, Earth Terminals, Numbering Etc. Complete In All Respect, Suitableformainfirepump, Pressurisationpump& Dieselpumpsetcompleteaspercpwdspecification Withfollowingincomingandoutgoings, Suitablefor Operationon415v, 3Phase, 50Hzacsupplywith Enclosure Protection Class Ip 42 As Required :Incomings:A ) 630A, 50Ka4 Pole Mccb, Ics=100% Icu Rating Digital Voltmeter 0-500V With Selector Switch Ammeter ( 0-630 A ) With Selector Swtich & Cts Etc.B ) Ledtyperybphaseindicatinglamps, On, Off, Trip Indicating Lampsset Of Copperbus Bar 800Ampsoutgoings: Main Fire Pump :200Amp, 50Katpnmccb, Ics=100%Icu, Withfully Automatic Star / Delta Starter Suitable For 75 Hp Pump With Overloadprotection, Currentsensingtypesinglephase Preventorcompletewithallacceessoriesandinternal Wiringrequiredforautomaticoperation, Selectorswitch For Local / Remote, Auto / Manual / Off Operation. - 2 Setsjockey Pump:100 Amp, 50Ka Tpn Mccb, Ics=100% Icu, With Suitable Hp Fully Automatic Star / Delta Starter With Overload Protection, Currentsensingtypesinglephasepreventor Complete With All Acceessories And Internal Wiring Requiredforautomaticoperation, Selector Switchfor Local / Remote, Auto / Manual / Off Operation. - 2 Setsdiesel Engine Controla ) Control For Diesel Engine Comprising - Automatic / Manualselctorswitch&3Attemptsstarting Device, Timersandrelaysasrequired, Pushbuttons, Start / Stop In Manual Modeb ) Indicatinglampforhigh / Lowlub.Oilpressure, High Water Temp And Engine On Indicationc ) Batterychargersuitbalefor12v / 24Vdcwithboost And Trickle Selector Switch, 0-30 V Dc Volt Meter, And 020 A Dc Ammeter All Standard Relays And Accessories For Automatic Operation Of Diesel Engine.System Controller: Designing, Supply, Installation, Testingand Commissioning Of System Controller To Control Operation Of Main Electric Fire Pump, Diesel Pump, Pressurization Pump, Terrace Pump In Sequence As Per Specification Consisting Of Relays, Timers. Sensors, Annunciation Windowforfaultindication, Complete As Per Specification 6 Providinglaying, Testing&CommissioningofCClass Heavydutymspipeconformingtois1239 / 3589I / C Fittingslikeelbows, Tees, Flanges, Tapers, Nutsbolts, Gasketsetc.Ingroundincludingwelding, Excavation& Providingcementconcreteblocksassupports, Anticorrosivetreatmentwithcoaltar / Asphalttapeasper Is10221, Refillingthetrenchetc.Offollowingsizes Complete As Required. 200 Mm. Dia ( Wall Thickness = 6.3 Mm ) 7 150 Mm. Dia 8 Providing, Laying, Testing&Commissioningof CClass Heavydutymspipeconformingtois3589 / Is1239 Includingwelding, Fittingslikeelbows, Tees, Flanges, Tapers, Nuts Bolts, Gaskets Etc. And Fixing The Pipe On The Wall / Ceiling With Suitable Clamp / Support Frame And Painting With Two Or More Coats Of Synthetic Enamel Paint Of Required Shade Complete As Required : 25 Mm Dia 9 32 Mm Dia 10 40 Mm Dia 11 50 Mm Dia 12 65 Mm Dia 13 80 Mm Dia 14 100 Mm Dia 15 150 Mm Dia 16 Providing, Laying, Testing&CommissioningofBClass Heavydutyg.I.Pipeconformingtois1239including Welding, Fittings Like Elbows, Tees, Flanges, Tapers, Nuts, Bolts, Gaskets Etc. And Fixing The Pipe On The Wall / Ceiling With Suitable Clamp / Support Frame And Painting With Two Ormorecoatsofsyntheticenamelpaintofrequired Shade Complete As Required: 25 Mm 17 32 Mm 18 40 Mm 19 50 Mm 20 65 Mm 21 80 Mm 22 100 Mm 23 150 Mm 24 Supplyingandfixingsingleheadedinternalhydrant Valve With Instantaneous Gunmetal / Stainless Steel Coupling Of 63 Mm Dia With Cast Iron Wheelisi Marked Conformingtois5290 ( Type-A ) Withblank Gunmetal / Stainless Steel Cap And Chain As Required :Single Headed Gunmetal 25 Supplying And Fixing Single Headed External Yard Hydrant Valve With 1 No. 63 Mm Dia Instantaneous Fm Gunmetal / Stainlesssteel Couplingand Cast Iron Wheel, Isimarked, Conformingtois5290 ( Typea ) Withblank Gunmetal / Stainless Steel Cap And Chain As Required :Single Headed Gunmetal 26 Supplying, Fixing, Testing And Commissioning Of Butterfly Valve Of Pn 1.6 Rating With Bronze / Gunmetal Seat Duly Isi Markedcompletewithnuts, Bolts, Washers, Gaskets Conforming To Is 13095 Of Following Sizes As Required :80 Mm Dia 27 100 Mm Dia 28 150 Mm Dia 29 Supplying, Fixing, Testing&Commissioningofdouble Flangedsluicevalveofratingpn1.6Withnonrising Spindle, Bronze / Gunmetalseat, Isimarkedcomplete With Nuts, Bolts, Washers, Gaskets And Conforming To Is 780 Of Following Sizes As Required : 80Mm Dia 30 100Mm Dia 31 150Mm Dia 32 200Mm Dia 33 250Mm Dia 34 Supplyingandfixingorificeplatemadeoutof6mm Thick Stainless Steel ( Grade 304 ) With Orifice Of Required Sizetobefitted Betweenflange&Landingvalveof Externalandinternalhydrantstoreducepressureat The Outlettothe Levelof 3.5Kg / Cm2 Complete As Required. 35 Providing, Installation, Testingandcommissioningof Non-Returnvalveoffollowingsizesconfirmingtois: 5312 Complete With Rubber Gasket, Gi Bolts, Nuts, Washers Etc.As Required.100Mm Dia 36 150Mm Dia 37 200Mm Dia 38 Providing, Installation, Testingandcommissioningof Stainlesssteely-Strainerfabricatedoutof1.6Mm Thickstainlesssteel, Grade304, Sheetwith3mmdia Holes With Stainless Steel Flange.150Mm Dia 39 200Mm Dia 40 Supplying And Fixing 63 Mm Dia, 15 M Long Rrl Hose Pipewith63mmdiamaleandfemalecouplingsduly Boundwithgiwire, Rivetsetc.Conformingtois636 ( Type-A ) As Required : Gun Metal 41 Supplying Andfixing First-Aidhosereelwithms Constructionspraypaintedinpostofficered, Conformingtois884completewiththefollowingas Required. A ) . 20Mmnominalinternaldiawaterhosethermoplastic ( Textile Reinforced ) Type -2 As Per Is: 12585 B ) .20Mmnominalinternaldiagunmetalglobevalve& Nozzle. C ) .Drum And Brackets For Fixing The Equipmets On Wall.D ) .Connections From Riser With 25 Mm Dia Stop Gun Metal Valve & M.S. Pipe And Socket. E ) .40 M 42 Supplying & Fixing 63 Mm Dia Gun Metal Short Branch Pipe With 20 Mm Nominal Internal Diameter Sizenozzle Conforming To Is 903 Suitable For Instantaneous Connection To Interconnect Hose Pipe Coupling As Required : Gun Metal 43 Supplyingandfixingoffirebrigadeconnectionof Cast Iron Body With Gun Metal Male Instantaneous Inlet Couplingscompletewithcapandchainasreqd.For Suitabledia Ms Pipe Connectionconforming To Is 904 As Required :2 Way-100 Mm Dia M.S. Pipe 44 4 Way - 150 Mm Dia M.S. Pipe 45 3 Way - 150 Mm Dia M.S. Pipe 46 Supplying And Fixing Air Vessel Made Of 250 Mm Dia, 8 Mm Thick Ms Sheet, 1200 Mm In Height With Air Release Valveontopandflangedconnectiontoriser, Drain Arrangementwith25mmdiagunmetalwheelvalve Withrequiredaccessories, Pressuregaugeand Paintingwith Synthetic Enamel Paint Of Approved Shade As Required. 47 Providing, Fixing, Testing & Commissioning Of 15Mm Dia Quartzoidbulbtypesprinklersofrating68degree Centigrade With Required Accessories :Pendent Sprinkler 48 Upright Sprinkler 49 Horizontal Side Wall Sprinkler 50 Concealed Sprinkler 51 Providing & Fixing Of Pressure Switch In M.S. Pipe Line Including Connection Etc. As Required. 52 Providing& Fixingflowswitchinfollowingsizesm.S. Pipe Including Connection Etc As Required. 53 100Mm Dia 54 150Mm Dia 55 Providing, Fixing, Testing & Commissioning Of Installationcontrolvalveofcastironbody, Brass / Bronzeworking Partscomprisingofwater Motor Alarm, Bronzeseatclapper, Clapperarmand Hydraulicallydrivenmechanicalgongbelltosound Continuousalarmwhenthewetriser / Sprinklersystem Activates, Pressuregauges, Emergencyreleases, Strainer, Pressureswitch, Cockvalvecompletewith Drainvalveandbypass, Testcontrolbox, Ballvalves, Ms Pipe Of Required Size, Flanges, Orifice Plate, Gasket Etc Of Follwing Sizes Asrequired : 150Mm Dia 56 Supplying, Installation, Testing & Commissioning Of Sprinklerflexiblepipe ( Ullisted ) Ofstainlesssteel Complete With 15 Npt On Reducer Thread With Maximum Working Pressure Of 175 Psi Test Pressure Of 875Psi ( Burst ) Withbranchline ( Inlet ) 25Mmnpt Malethreadtosprinklerhead ( Outlet ) 15Mmnpt Femalethreadwithreducer, Nipple, 2Sidebrackets, Center Bracket, Stockbar Of Following Sizes Complete As Required.700Mm 57 1000Mm 58 1200Mm 59 1500Mm 60 Providing And Fixing In Position The Industrial Type Pressure Gauges With Gun Metal / Brass Valves Complete As Required ( E&M ) 61 Providing And Fixing Ms Cabinet ( Size 750X600x250 Mm ) Fabricated From 16 Gauge Ms Sheet With Full Front Glass Door & Locking Arrangement For Pad Lockwith Suitable Shelves For Keeping 25 Nos. Spare Sprinklers & One No. Spanner Properly Fixed In Shelves. Cabinet Shall Be Painted With Enamel Paint Of Approved Shade. ( Cost Shall Include 20 Nos. Spare Sprinklers ( 5 Nos Side Wall 20Nos Pendent, One No. Spanner And 5 Rolls Of Teflon Tape ) . Note: All Valves Shall Be Of Pn16 Rating 62 Portable Fire Extinguishers: Providing & Fixing Of Isi Marked ( Is:15683 ) Portable Fire Extinguisher, Carbondioxide Type Flat Base Including Valve, Discharge Hose Of Not Less Than 10 Mm Dia. 1 M Long & Complete In All Respects Including Initial Fill With Co2 Gas Confirming To Is:307-1966 Filled To A Filling Ratio Of Not More Than 0.667 Of Not More Than 0.667 And Wall Suspension Bracket Capacity 4.5 Kg 63 6 Kg. Abc Powder Type Fire Extinguishers Are Manufactured And Marked To Indian Standard Is: 15683. Suitable First Aid Appliance For Fighting Fires In Class A, B & C Fire That Is Wood, Textile, Flammable Liquids & Gases. 64 Providing And Fixing Mechanical Foam Type Fire Extingushers Consisting Of Welded M.S. Trolley Mounted Cylindrical Body, Squeeze Lever Discharge Valve Fitted With Pressure Discharge Hose, Discharge Nozzle, Trolley Etc., Isi Marked As Per Is:Is:13386 Finished Externally With Red Enamel Paint.Capacity 50 Lit ( D.G.Room ) 65 Providing And Fixing Carbon-Di-Oxide Fire Extingushers Trolley Mounted With All Accessories Internal Discharge Tube, High Pressure Discharge Hose, Discharge Nozzle, Isi Marked As Per Is:2878 Finished Externally With Red Enamel Paint. Capacity 22.5 Kg. 66 Boq-D: Plumbing Pump & Equipmentswater Supply, Drainage, Pumps & Equipment :Providingand Fixing Centralized Water Level Controller Cum Indicator System, As Per The Following Details:Centralised Plc Control Panel : Along With Touch-Screen Display Board ( Min. 8 Diag. Size ) Along With All Accessories For Complete Controls & Indication. Panel Shall Be Made Out Of Crca Sheet Min. 2Mm Thick Having Necessary Interlocks, I / OS, Required Number Of Repeater Amplifiers, All Audio-Visual Alarms As Required Specifications As Listed Below. An Emergency Stop Push Button Shall Be Provided In The Panel. The Panel Shall Have Modbus Compatibility For Seamless Bms / Bas Integration And Shall Be Of Approved Make. The Complete System Control Matrix, Wiring Diagram, SldS And Technical Details Shall Be Submitted By The Vendor And Gotten Approved Before Commencement Of Execution Of Works. Water Level Indicators Cum Controllers :Working On Hydrostatic Pressure Measurement Principle Made Of Stainless Steel For Installation On Storage Tanks, And Capable Of Providnig 4 To 20 Ma Analog Signal Compatiblewith Plc Signal Inputs And Completeas Per Working Requirements For Details Of Equipment Below. All Control Outputs To Mcc Panel Shall Be Included As Per Requierments. A ) .Fire Static Underground Tanksb ) .Real-Time Water Level Indication Monitoring 67 V. Low Level Audio-Visual Alarm At Less Than 25% Total Capacity.Raw Water Underground Tanksreal-Time Water Level Indication Monitoring V. Low Level Audio-Visual Alarm At Less Than 30% Total Capacity. V. High Level Audio-Visual Alarm At More Than 100% Total Capacity.Auto Cut-In Of Tubewell Pumps At 35%Auto Cut-Out Of Tubewell Pumps At 95% 68 Auto Cut-Out Of Raw Water Pumps At 35%Domestic Water Underground Tanks Real-Time Water Level Indication Monitoring V. Low Level Audio-Visual Alarm At Less Than 30% Total Capacity. V. High Level Audio-Visual Alarm At More Than 100% Total Capacity. Auto Cut-In Of Raw Water Pumps At 35% 69 Auto Cut-Out Of Domestic Water Pumps At 35% Flushing Water Underground Tanks At Stpreal-Time Water Level Indication Monitoringv. Low Level Audio-Visual Alarm At Less Than 30% Total Capacity.V. High Level Audio-Visual Alarm At More Than 100% Total Capacity.Auto Cut-In Of Raw Water Pumps ( From Stp ) At 35% 70 Auto Cut-Out Of Flushing Water Pumps At 35% Domestic Water Overhead Tanksreal-Time Water Level Indication Monitoring V. Low Level Audio-Visual Alarm At Less Than 30% Total Capacity. 71 V. High Level Audio-Visual Alarm At More Than 100% Total Capacity. Flushing Water Overhead Tanksreal-Time Water Level Indication Monitoring V. Low Level Audio-Visual Alarm At Less Than 30% Total Capacity. 72 V. High Level Audio-Visual Alarm At More Than 100% Total Capacity. 73 Providing Complete Testing Kit With All Chemicals Complete Suitable For Conducting Test On Water Quality.The Test Kit Shall Be Suitable To Measure Tds, Ph, Hardness, Iron Content And Other Parameters 74 Hydro-Pneumatic Pumping System For Domestic Supply To Fixture ( Toilet Kitchen ) : Providing, Fixing And Testing Of Packaged Type Skid Mounted Hydropneumatic System With Variable Frequency Drive Type Comprising Of : ( I ) Vertical, Inline Multistage Centrifugal Pumping Set With Stainless Steel Ss-304Stage Casing And Ss-304 Impellers With Stainless Steel Ss-304 Shaft As Per Iecstandards And Gjl250 Cast Iron Suction& Discharge Casing, Connected To Tefc Ventilated Induction Motor Of2 Pole, 2900Rpm, Suitable For 400 / 440 Volts, 3 Phase, 50 Hz A.C. Supply. ( Ii ) Pressure Vessel Of Non Corrosivefrp Composite Construction Lined With Nsf And / Or Fda Listed Material, Likehigh Density Polyethylene With Fully Replaceable Polyurethane. Air Cell Burstpressure Of Minimum Of 5 Times The Vessel Operating Pressure And Cycle Tested For 2, 50, 000 Cycles. ( Iii ) Control Panel With Programmable Logic Controller ( Plc ) For Cyclic Operation Of Pumps + Variable Frequency Drive. The Pump Workingsequence Should Change After Every Operation.Contractor Overload Relays And Mcbs Should Confirm To Iec 898 – 1995 / Specifications. Blinking Indications For Pumps Start, Trip, Low Level Trip, Health Supply Should Be Provided In The Panel Along With The Ammeter& Voltmeter. Control Panel Should Also Consist Of Cooling Fan. ( Iv ) Pressure Switches Bellowtypefittedwithmicro Switch And Having Maximum Pressure And Differentialscaleshould Confirming Bs-6134 Standards And Ip55 Protection Class. ( V ) All Required Ball Valves, Non-Return Valves, Flexible Connectors Etc. And All Required Accessories, Heavy Duty S.S 316 Manifold To Make The System Completely Operational As A Skid Mounted System. Ball Valves Tobe Used Should Be Hot Pressed Brass Ot-58Withstainless Steelballand P.T.F.Eseal And O-Ring. Nrvs To Be Used Shouldbewithspringsando-Ring Arrangement. ( Vendor To Submit Performance Curves And Technical Catalog Of The Proposed Model For Review & Information ) Complete Manifold System Shall Be Factory Aasembled & Totally Mounted On A Common Base Frame With Following Duties:Note: Contractor To Note That The Suction Header Is Required To Have Inlet Connection From The Puddle Flange @ Water Tanks And To The Pump Suction. Provision Of Delivery Header Is Required To Have Outlet Connection From The Pumps. Suitable Outlet Flanges From The Delivery Mainfold / Header Shall Be Provided As Required.A.For Domestic Water Supply For Club & Benquet Hall: No. Ofpumps :1 ( 1 Working +1 Standby ) Capacity: 350 Lpm Each Pump Head: 55 Meters Apx. Hp ( Motors ) : 3 Hp Location : Plumbing Plant Room 75 For Flushing Water Relift Pump :No. Ofpumps :1 ( 1 Working +1 Standby ) Capacity: 250 Lpm Each Pump Head: 55 Metersapx. Hp ( Motors ) : 2 Hplocation : Stp Plant Room 76 Garden Hydrents & Floor Washing Relift Pump:Providingand Fixing Vertical, Inline Multistage Centrifugalpumpingset ( Complete Manufactured Skid-Mounted Arrangement With Manifold And Accessories ) Withstainlesssteelss-304Stage Casingandss-304Impellerswith Stainless Steel Shaft As Per Iec Standards And Gjl250 Cast Iron Suction & Discharge Casing, Connected To Tefc Ventilated Induction Motor Of 2 Pole, 2900 Rpm, Suitablefor 400 / 440 Volts, 3 Phase, 50 Hz A.C. Supply With Pressure Gauge And With Gunmetal Isolationcocks, Vibrationelimination Pads Etc. Complete With Base And Frame, Nuts And Boltsandnecessary Rcc Foundations As Per Requirementasper Instructionsandpumpshallhave Following Duty:No. Ofpumps :2 ( 1 Working +1 Standby ) Capacity: 200 Lpm Each Pumphead: 45 Metersapx. Hp ( Motors ) : 4 Hplocation : Stp Plant Room 77 Supply, Installation, Testing & Commissioning Of Continuous Duty Submersible Centrifugal Non-Clogging Drainage Pumps Of Efficiency Of Approved Make Complete With 3 Phase Motor With All Necessary Protection And Mechanical Seal Etc. Complete With All Ancillaries Including Float Type Level Controllers, Electrical Control Panels Fabricatd From 14 Gauge Crca Sheet Volt Meter Ammeter With Selector Switch, Tpmcb, 5 Va Cl : Cts, Phase Indicating Lamps Protected By 2 Amp Sp Mcb, Dol Starter, Necessary Wiring, Cable Alleys, Earthing, Interlocking, Starter With Automatic Float Type Level Controller, Providion Of High Level Alarm, Sequence Timer, Potential Free Contact To Starter For Connection To Bas, Both Pumps May Run Simultaneously At Pre Determind Level. ( 1 Working + 1 Standby ) Vendor To Submit Proposed Pump Model With Duty Curve.A ) . For Wtp & Stp Plant Room Drainage :Flow Rate : 450 Lpm Head : 15 Mtssolid Handling : 100 Mmlocation : Sump Of Basement Purpose : Plant Room & General Area Drainage Moc : Ss Body Ss Impeller & Shaft 78 B ) .For Basement Drainage : Flow Rate : 450 Lpm Head : 15 Mts Solid Handling : 100 Mmlocation : Sump Of Basement Purpose : Basement Area Drainage Moc : Ss Body Ss Impeller & Shaft 79 C ) .Manhole Cover For U.G Tanks And Sumps :Supplying And Fixing C.I. Cover Without Frame For Manholes :560Mm Diameter C.I Cover ( Heavy Duty ) The Weight Of The Cover To Be Not Less Than 108Kg. 80 F ) .Providing And Fixing Stainless Steel Ladder, Wall Mounted Of 4M Height ( App ) For Underground Tanks Complete With Flanged Ends And Inserts ( Removable Type ) Made Of 38Mm / 42Mm Dia 16 G S / S 304 Quality Pipe Made As Per International Quality Standards Of Approved Shape And Size With Non Skidding Stepsat 300Mm Vertical Spacing, Completeas Directed By The Engineer In Charge. 81 Water Treatment Plant: Providing & Fixing Vertical, Inline Multistage Centrifugalpumping Set ( Complete Manufactured Skid-Mounted Arrangement With Manifold And Accessories ) With Stainlesssteel Ss-304 Stage Casing And Ss-304 Impellers With Stainless Steel Shaft As Per Iec Standards And Gjl250 Cast Iron Suction & Discharge Casing, Connected To Tefc Ventilated Induction Motor Of 2 Pole, 2900 Rpm, Suitable For 400 / 440 Volts, 3 Phase, 50 Hz A.C. Supply With Pressure Gauge And With Gunmetal Isolation Cocks, Vibration Elimination Pads Etc. Complete With Base And Frame, Nuts And Bolts And Necessary Rcc Foundations As Per Requirement As Per Instructions And Pump Shall Have Following Duty:A ) .For Club Building Only : No. Ofpumps: 2 ( 1 Working + 1 Standby ) Flow Rate :150 Lpm Each Head : 30 Mtsrequired For : Filter Feed Pump In Plumbing Plant Room ( 1Working + 1Standby ) 82 Providing And Fixing Vertical Pressure Filter With Dual Media Filter ( Comprising Of 600Mm Bed Depth Of Graded Sand Gravel And 600Mm Bed Depth Of Anthracite ) Fabricated From High Performance M.S Plate Of Minimum 8Mm Thick For Shell & 10Mm Thickfor Dished Ends With Top And Bottom Flanged Openings Including Top And Bottom Hub And Lateral Distribution And Collection System Complete With Initial Charge Of Filter Media, Face Piping, Valves, Accessories, Painting, Testing And Commissioning Complete. ( Tested To 6 Kg / M2 ) Discharge : 150 Lpm Filtration Rate: 17500 Lit. / M2 / H Discharge : 150 Lpm Suggested Dia App.: 0.90 M 83 Activated Carbon Filter ( Domestic Water ) : Providing And Fixing Vertical Activated Carbon Filter Comprising Ofactivated Carbon Filter Media Fabricated From High Performance M.S Plate Of Minimum 8Mm Thick For Shell & 10Mm Thickfor Dished Ends With Top And Bottom Flanged Openings Including Top And Bottom Hub And Lateral Distribution And Collection System Complete With Initial Charge Of Filter Media, Face Piping, Valves, Accessories, Epoxy Painting, Testing And Commissioning Complete. ( Tested To 6 Kg / M2 ) Discharge :100 Lpm Filtration Rate: 15000 Lit. / M2 / H Suggested Dia App.: 0.60 M 84 Providing, Fixing, Testing & Commissioning Of Msep Water Softening Plant ( Suitable For 3 Kg / Sqcm Workingpressure ) Complete With Initial Charge With T-40 Na Resin, Multiport Valve With Built In Ejector For Controlling All Operations ) , Regeneration System And Hdpe Tank, Pressure Gauge At Inlet, Outlet And Back Wash ( Each With Isolation Cock ) , Valves, Fittings And Water Hardness Testing Kit & Associatedworks. Softener Shall Be Suitable For The Following Duty:Note:The Successful Contractor Will Have To Carry Out A Test Of Raw Water From All The Sources Of Water For The Commercial, Residential & Apartment At Their Own Cost From A Reputed Lab As Approved By The Engineer-In-Charge / Consultant. On The Basis Of These Results The Contractor Has To Submit His Shop Drawings, Design Calculations And Specifications Accordingly.Please Note That It Is Ultimately The Responsibility Of The Contractor To Provide Treated Water For Different Use As Per International Standard As Given In The Attached Guidelines. Raw Water Hardness: 500 Mg / Ltreated Water Hardness:100 Mg / L Regeneration Period:12 Hrs.Capacity : 100 Lpm 85 Supplying, Installing, Testing And Commissioning Of Dosing System ( For Domestic Water Treatment Plant ) Consisting Of One Hdpe Tank Of 100 Litres Capacity With A Positive Displacement Diphragm Dosing Pump Having Variable Flowrate Of 0-6 Lph. The Motor Shall Be Suitable For Operation At 240 V / Single Phase / 50 Hz. Supply. The Pump Shall Be Supplied Complete With Necessary Polypropylene Piping, Valves, Strainers, Low Level Switch Andinjection Fittings. The Pump Shall Be Speed & Stroke Control Asialmi / Equivalent Make. The Cost Shall Be Inclusive Of Providing Salt For The Testing And Operation Of System Before Handover To The Owner. 86 Plumbing Panel: Design, Manufacture, Assembly, Wiring, Testing At Works And Supply To Site Of Following Panels / Distribution Boards / Switch Boards. The Boards Shall Be Designed And Fabricated As Per General Specifications, Technical Details, Specifications And Notes As Part Of This Tender / Boq And Relevant Bis Codes. ( Any Load Veriation In System As Technical Document Of Manifactureno Cost Shall Be Paid Extra For System Requirments ) Ip Rating: Ip 54 Incomer:1 No. 250 A 25 Ka, 3P Mccb Of Motor Duty - Only Magnetic Release. ( Adjustable Magnetic Release Upto 250A Mccb Or Micro-Processor Based Release Above 250A Mccb ) .Incomer Metering & Indication: A ) .415V / V3 / 110V / V3ptS, Cast Resin Type, 3 Phase For Metering & Indications, Suitable Rated 6A, Tp Mpcb Of The Fault Withstand Capacity As Of The Panel On The Primary Side Of Pt & Suitable Rated 6A, Tp Mcb On The Secondary Side Of Pt.B ) .R, Y, B Phase Indication Lamps ( 110V ) Led Type C ) .Cast Resin Metering CtS For Each Phase Of Class-1 Accuracy & Of Suitable Burden & Ratio D ) .1 No. Digital Vaf + Pf Meter ( 110V ) ( *With / Without Rs 485 Port ) Bus Bars : 400A, Tp, Aluminium Bus Bars Of Electrolytic Grade With Heat Shrinkable Sleeves 25 Ka. Control Transformer & Control Circuiting For Starters / Contactors & Indication Lamps : A ) .1 No. 415V / 55-0-55Vcast Resin Dry Type Control Transformer Of Adequate Va Burden To Take Care Of Load Of All The Contactor Coils. ( Transformer With Primary Taps At ± 2.5%, ± 5%, 50 Hz, Centre Tap Earthed ) .B ) .Suitable Rated 6A, Dp, Mpcb Of The Fault Withstand Capacity As Of The Panel For Control Circuiting For Contactors Coils On The Primary Side Of Control Transformer & Suitable Rated 6A, Dp Mcb On The Secondary Side Of Control Transformer.C ) .110V Control Circuiting D ) .110V Control Supply Healthy Indication ( Led Type ) .Outgoings: A ) .Dol Starter Comprising The Following ( For Upto 2 Hp Motors ) For Raw Water Pumps / Treated Water Transfer Pump / Flushing Water Transfer Pump / Borewell / Soft Water Transfer Pump / For Pump Room Fresh Air Fan / For Pump Room Exhaust Air Fan:A ) . For 1Hp. ( 2 Nos. ) ( Chamical Dosingpump ) B ) .Type-2 Co-Ordinationc ) . 1 No. Suitable Rated Tp Mpcb, 10Ka, With Inbuilt O / L Relay & Inbuilt Spp Feature ( Site Adjustable ) D ) .Suitable Sized 3P Contactor With 2 No & 2 Nc Auxiliary Contactse ) . On / Off / Trip Indication Lamps ( 110V ) ( Led Type ) F ) .On / Off Push Buttons G ) Star-Delta Timerh.2 Pole A / M Selector Switch For Bms Application I ) .Suitable Rated Single Cast Resin Ct For Metering On Y Phase, Of Class-1 Accuracy & Of Suitable Burden & Ratio. J ) .Digital Ammeter K ) .On / Off-Trip / A / M Potential Free Contacts For Bmsl ) .Control Wiring Terminals For Auto Operation Through Potential Free Contacts Ofwater Tank Level Controllers.B ) .Dol Starter Comprising The Following ( For 3 Hp To 5 Hp Motors ) For Raw Water Pumps / Treated Water Transfer Pump / Flushing Water Transfer Pump / Borewell / Soft Water Transfer Pump / For Pump Room Fresh Air Fan / For Pump Room Exhaust Air Fan :A ) For 4 Hp. ( 2 Nos. ) ( For Pump Room Exhaust Air Fan ) B ) Type-2 Co-Ordination C ) 1 No. Suitable Rated Tp Mpcb, 25 Ka, With Inbuilt O / L Relay & Inbuilt Spp Feature ( Site Adjustable ) D ) Suitable Sized 3P Contactor With 2 No & 2 Nc Auxiliary Contactse ) On / Off / Trip Indication Lamps ( 110V ) ( Led Type ) F ) 2 Pole A / M Selector Switch For Bms Application G ) Suitable Rated Single Cast Resin Ct For Metering On Y Phase, Of Class-1 Accuracy And Of Suitable Burden & Ratioh ) Digital Ammeter With Inbuilt Selector Switch I ) Digital Ammeter J ) On / Off-Trip / A / M Potential Free Contacts For Bmsk ) Control Wiring Terminals For Auto Operation Through Potential Free Contacts Ofwater Tank Level Controllers.C ) .Dol Starter Comprising The Following ( For 7.5 Hp To 10 Hp Motors ) For Raw Water Pumps / Treated Water Transfer Pump / Flushing Water Transfer Pump / Borewell / Soft Water Transfer Pump / For Pump Room Fresh Air Fan / For Pump Room Exhaust Air Fan:A ) For 7.5Hp. ( 2 Nos. ) ( Raw Water / Filter Feedpump ) B ) . For 6 Hp. ( 2 Nos. ) ( Soft Water Reliftingpump ) C ) .Type-2 Co-Ordinationd ) .1 No. Suitable Rated Tp Mpcb, 10 Ka, With Inbuilt O / L Relay & Inbuilt Spp Feature ( Site Adjustable ) E ) .Suitable Sized 3P Contactor With 2 No & 2 Nc Auxiliary Contacts F ) .On / Off / Trip Indication Lamps ( 110V ) ( Led Type ) G ) .On / Off Push Buttons ( With Lockable Off ) H ) . Pole A / M Selector Switch For Bms Application I ) .Suitable Rated Cast Resin CtS For Metering On Each Phase, Of Class-1 Accuracy And Of Suitable Burden & Ratioj ) .Digital Ammeter With Inbuilt Selector Switch K ) On / Off-Trip / A / M Potential Free Contacts For Bms L ) .Control Wiring Terminals For Auto Operation Through Potential Free Contacts Ofwater Tank Level Controllers. D ) .Star-Delta Starter Comprising The Following ( For 12.5 Hp To 25 Hp Motors ) For Raw Water Pumps / Treated Water Transfer Pump / Flushing Water Transfer Pump / Borewell / Soft Water Transfer Pump / For Pump Room Fresh Air Fan / For Pump Room Exhaust Air Fan:A ) .12.5 Hp. ( 3 Nos. ) ( Tubewells Pump ) B ) .Type-2 Co-Ordinationc ) .1 No. Suitable Rated Tp Mpcb, -----Ka, Without Inbuilt O / L Relay ( Only Magnetic ) D ) .Suitable Sized 3P Contactors ( Star, Delta & Run Contactors ) With 2 No & 2 Nc Auxiliary Contactse ) Suitable O / L Relay With Inbuilt Spp F ) .On / Off / Trip Indication Lamps ( 110V ) ( Led Type ) G ) .2 Pole A / M Selector Switch For Bms Application H ) .Suitable Rated Cast Resin CtS For Metering On Each Phase, Of Class-1 Accuracy And Of Suitable Burden & Ratioi ) Digital H Inbuilt Selector Switch J ) On / Off-Trip / A / M Potential Free Contacts For Bms K ) Control Wiring Terminals For Auto Operation Through Potential Free Contacts Ofwater Tank Level Controllers. Feeders ( Without Starters ) For Hydronumatic Pump Panels :1 No. Suitable Rated 15 Ka, Tp, Mpcb Without Inbuilt O / L Relay & With 1 No + 1 Nc Auxiliary Contacts & On Indication Lamp 110V ( Led Type ) For 10 Hp Sump Pump Panel. Suitable Rated Cast Resin CtS For Metering On Each Phase, Of Class-1 Accuracy And Of Suitable Burden & Ratio. Digital Ammeter With Inbuilt Selector Switch. Feeders ( Without Starters ) For Sump Pump Panels : 2 No. Suitable Rated 15 Ka, Tp, Mpcb Without Inbuilt O / L Relay & With 1 No + 1 Nc Auxiliary Contacts & On Indication Lamp 110V ( Led Type ) For 15 Hp Sewarage Sump Pump Panel. Suitable Rated Cast Resin CtS For Metering On Each Phase, Of Class-1 Accuracy And Of Suitable Burden & Ratio. Digital Ammeter With Inbuilt Selector Switch. Feeders ( Without Starters ) For R.O Water Booster Pump Panels : 1 No. Suitable Rated 10 Ka, Tp, Mpcb Without Inbuilt O / L Relay & With 1 No + 1 Nc Auxiliary Contacts & On Indication Lamp 110V ( Led Type ) For 3 Hp R.O Waterbooster Pump Panel. Suitable Rated Cast Resin CtS For Metering On Each Phase, Of Class-1 Accuracy And Of Suitable Burden & Ratio. Digital Ammeter With Inbuilt Selector Switch.Spare Starter Feeders ( Without Starters ) With Same Components As Described In Above Written Similar Starter Feeders:5 Hp Motors, Dol Starter ( 2 Nos. ) ( Spare Feeders ) Spare Motor Feeders ( Without Starters ) With Same Components As Described In Above Written Similar Feeders: 2 No. Suitable Rated 15 Ka, Tp, Mpcb Without Inbuilt O / L Relay & 1 No + 1 Nc Auxiliary Contacts & On Indication Lamp ( 110V ) Led Type For 10 Hp Feeder. Suitable Rated Cast Resin CtS For Metering On Each Phase, Of Class-1 Accuracy And Of Suitable Burden & Ratio. Digital Ammeter With Inbuilt Selector Switch. 1 No. Suitable Rated 10 Ka, Tp, Mpcb Without Inbuilt O / L Relay & 1 No + 1 Nc Auxiliary Contacts & On Indication Lamp ( 110V ) Led Type For 5 Hp Feeder. Suitable Rated Cast Resin CtS For Metering On Each Phase, Of Class-1 Accuracy And Of Suitable Burden & Ratio. Digital Ammeter With Inbuilt Selector Switch.Vendor Can Also Consider Integrated Total Co-Ordinated Starter Upto 15Hp.Plumbing Panel As Described Above. 87 Sump Pump Panel ( Upto 5.0Hp Motor ) : A ) .It Shall Control Two Pumps P-1 And P-2. The Operation Sequence Will Be As Under :B ) .P-1 & P-2 To Stop At L-1 C ) .P-1 To Start At L-2 D ) .P-2 To Start At L-3 ( At L-3 Both Pump Will Be Running ) Audible Alarm At L-4 ( 50 Mtr Range ) .E ) .Hooter For Annunciation ( Solid State Buzzer ) F ) .Where L-1 < L-2 < L-3 < L-4 ( Level Of Water In The Sump ) ( Probes / Sensors To Control Operation ) G ) .There Shall Be Selector Switch To Interchange The Starting Sequence Between P1 & P2. ( Selection Mode ) Important Features : Sump Pump Panel Shall Have Following Essential Features: R, Y, B Phase Indicating Lamps With Backup. Auto / Manual Selector Switch. Starter On / Off & High Level Indications, Digital Ammeters For Both Pumps. Mpcb With Inbuilt O / L & Spp, Dol Starter And Dry Run Protection Suitable For Motors And As Per Details Given Below : Incomer:1 No. Suitable Rated 35 Ka, Tp, Mpcb Without Inbuilt O / L & With 1No + 1Nc Auxiliary Contacts For Total 10 Hp Of Sump Pumps ( Both Pumps Working Simultaneously ) .Incomer Metering & PtS :415V / V3 / 110V / V3ptS, Cast Resin Type, 3 Phase For Metering & Indications, Suitable Rated 6A, Tp Mpcb Of The Fault Withstand Capacity As Of The Panel On The Primary Side Of Pt & Suitable Rated 6A, Tp Mcb On The Secondary Side Of Pt. 3 Nos. Cast Resin CtS Of Adequate Class, Burden & Ratio At The Incomer Metering.R, Y, B ( 110V Ac ) Led Lamp & On / Off Indications ( 110V Ac ) Led Type.Digital Vaf Meter At The Incomer ( 110V ) . Control Transformer & Control Circuiting For Starters / Contactors & Indication Lamps : A ) .1 No. 415V / 55-0-55Vcast Resin Dry Type Control Transformer Of Adequate Va Burden To Take Care Of Load Of All The Contactor Coils. B ) .Suitable Rated 6A, Dp, Mpcb Of The Fault Withstand Capacity As Of The Panel For Control Circuiting For Contactors Coils On The Primary Side Of Control Transformer & Suitable Rated 6A, Dp Mcb On The Secondary Side Of Control Transformer. ( Transformer With Primary Taps At ± 2.5%, ± 5%, 50 Hz, Centre Tap Earthed ) . C ) .110V Control Circuitingd ) .110V Control Supply Healthy Indication ( Led Type ) .E ) .Pt Of Adequate Burden Can Also Be Used For Powering Contactor Coils Of Starters And In That Case Control Transformer Can Be Eliminated. Bus Bars : 100A, Tp, Aluminium Bus Bars Of Required Capacity & Ka Rating With Heat Shrinkable Sleeves.Outgoings:Sump Pump Panel ( Upto 5.0Hp Motors ) : 2 Sets Suitable Rated 15 Ka, Tp, MpcbS With Inbuilt O / L Relay & Inbuilt Spp Features ( Site Adjustable ) & With 1No + 1Nc Auxiliary Contacts For 5Hp Each Sump Pump Motor & Each Set With The Following:A ) .Suitable Sized 3P Contactor With 2No + 2Nc Auxiliary Contacts B ) .On / Off / Trip Led Indications ( 110V ) C ) .On / Off Push Buttons D ) .2 Pole A / M Selector Switch For Bms Application E ) .Suitable Rated Single Cast Resin Ct For Metering On Y Phase, Class-1 Accuracy & Of Suitable Burden & Ratio. F ) . Digital Ammeter G ) .On / Off / Trip / A / M Potential Free Contacts For Bmsh ) .3 Nos. Suitable Water Level Controllers With Three Electrodes ( 110Ac ) The Sump Pump Control Panel Shall Be Complete With All Interconnections, Water Level Controllers & Sensors / Probes, Risers, Internal Wiring, Labels, Terminal Block Etc Complete As Required. 88 Sump Pump Panel ( For 7.5Hp To 10.0Hp Motor ) : A ) .It Shall Control Two Pumps P-1 And P-2. The Operation Sequence Will Be As Under :B ) .P-1 & P-2 To Stop At L-1 C ) .P-1 To Start At L-2 D ) .P-2 To Start At L-3 ( At L-3 Both Pump Will Be Running ) Audible Alarm At L-4 ( 50 Mtr Range ) .E ) .Hooter For Annunciation ( Solid State Buzzer ) F ) .Where L-1 < L-2 < L-3 < L-4 ( Level Of Water In The Sump ) ( Probes / Sensors To Control Operation ) G ) .There Shall Be Selector Switch To Interchange The Starting Sequence Between P1 & P2. ( Selection Mode ) Important Features : Sump Pump Panel Shall Have Following Essential Features: R, Y, B Phase Indicating Lamps With Backup. Auto / Manual Selector Switch. Starter On / Off & High Level Indications, Digital Ammeters For Both Pumps. Mpcb With Inbuilt O / L & Spp, Dol Starter And Dry Run Protection Suitable For Motors And As Per Details Given Below : Incomer:1 No. Suitable Rated 35 Ka, Tp, Mpcb Without Inbuilt O / L & With 1No + 1Nc Auxiliary Contacts For Total 10 Hp Of Sump Pumps ( Both Pumps Working Simultaneously ) .Incomer Metering & PtS :A ) .415V / V3 / 110V / V3ptS, Cast Resin Type, 3 Phase For Metering & Indications, Suitable Rated 6A, Tp Mpcb Of The Fault Withstand Capacity As Of The Panel On The Primary Side Of Pt & Suitable Rated 6A, Tp Mcb On The Secondary Side Of Pt. B ) .3 Nos. Cast Resin CtS Of Adequate Class, Burden & Ratio At The Incomer Metering.C ) .R, Y, B ( 110V Ac ) Led Lamp & On / Off Indications ( 110V Ac ) Led Type.D ) .Digital Vaf Meter At The Incomer ( 110V ) . Control Transformer & Control Circuiting For Starters / Contactors & Indication Lamps : A ) .1 No. 415V / 55-0-55Vcast Resin Dry Type Control Transformer Of Adequate Va Burden To Take Care Of Load Of All The Contactor Coils. B ) .Suitable Rated 6A, Dp, Mpcb Of The Fault Withstand Capacity As Of The Panel For Control Circuiting For Contactors Coils On The Primary Side Of Control Transformer & Suitable Rated 6A, Dp Mcb On The Secondary Side Of Control Transformer. ( Transformer With Primary Taps At ± 2.5%, ± 5%, 50 Hz, Centre Tap Earthed ) . C ) .110V Control Circuitingd ) .110V Control Supply Healthy Indication ( Led Type ) .Pt Of Adequate Burden Can Also Be Used For Powering Contactor Coils Of Starters And In That Case Control Transformer Can Be Eliminated. Bus Bars : 100A, Tp, Aluminium Bus Bars Of Required Capacity & Ka Rating With Heat Shrinkable Sleeves.Outgoings:Sump Pump Panel ( For7.5Hp To 10.0Hp Motor ) : 2 Sets Suitable Rated 15 Ka, Tp, MpcbS With Inbuilt O / L Relay & Inbuilt Spp Features ( Site Adjustable ) & With 1No + 1Nc Auxiliary Contacts For 5Hp Each Sump Pump Motor & Each Set With The Following:A ) .Suitable Sized 3P Contactor With 2No + 2Nc Auxiliary Contacts B ) .On / Off / Trip Led Indications ( 110V ) C ) .On / Off Push Buttons D ) .2 Pole A / M Selector Switch For Bms Application E ) .Suitable Rated Single Cast Resin Ct For Metering Oneach Phase Of Class-1 Accuracy & Of Suitable Burden & Ratio. F ) . Digital Ammeter G ) .On / Off / Trip / A / M Potential Free Contacts For Bmsh ) .3 Nos. Suitable Water Level Controllers With Three Electrodes ( 110Ac ) The Sump Pump Control Panel Shall Be Complete With All Interconnections, Water Level Controllers & Sensors / Probes, Risers, Internal Wiring, Labels, Terminal Block Etc Complete As Required. 89 Sewage Treatment Plant:Sewage Treatment Plant Based On Mbbr ( Moving Bed Bio Reactor ) Technology :Supply, Installation, Testing And Commissioning Of Package Type Pre-Fabricated Sewage Treatment Plant Based On Mbbr Technology ( Moving Bed Aerobic Bio-Reactor ) Of 65 Kld Capacity Including All Ms Structure, Mechanical, Electrical And Instrumentation Works As Per Technical Specification Mentioned In The Document. The Scope Shall Also Include To Provide The Ss Bar Screen In Grit Screen Chambers, Grease Separator, Primary & Secondary Treatment Of Waste Water, Air Blowers, All Necessary Interconnecting Piping & Valves, Pumps, Dmf And Acf Filters, Chlorinator, Ultravoilet Dis-Infection Unit, Mcc For Operation Of All Motors, All Inter Connecting Power And Control Wiring, Level Controllers & Other Controls, Ms Puddle Flange ( Hot Dip Galvanized After Fabrication ) , Inlet, Outlet, Overflow, Vent, Manhole Cover Etc, Completed In All Respect In Ready To Use And Easy To Transport Condition. ( The Entire System Tobe Installed Above Ground ) .A ) .Nature Of Effluent - Domestic Sewage From Toilets / Kitchen.B ) .Flow Rate - 65 Kld C ) .Sewage Incoming Characteristics D ) .Ph - 6.5 - 8.5 E ) .Bod5 - Upto 250 - 400 Mg / L F ) .S. Solid - 250 To 450 Mg / Lg ) .Cod 5 - Upto 600 Mg / L H ) .Oil & Grease - 50 Mg / L I ) .Effluent Discharge Standard After Treatment J ) .Ph - 6.5 - 7.5K ) .Bod5 - Less Than 10 Mg / L L ) .S. Solids - Less Than 10 Mg / L M ) .Cod - Less Than80 Mg / L N ) .Oil & Grease - Less Than 5 Mg / L Sewage Treatment Plant Shall Include The Following Items:A ) .Oil & Grease Chamber B ) . Sewage Equalization Tank C ) .Mbbr Tank ( Moving Bed Bio Reactor ) D ) .Tube Settling Tanke ) .Sludge Holding Tank F ) .Chlorine Contact Tank G ) .Filtration Through Mgf, Acf, Chlorinator & Uv Sterlizerh ) .Air Blowers, Pumps & Equipmenti ) .Filter Pressj ) .Piping, Valves Etc K ) .Electrical Panel & Cablingl ) .All Piping, Valves & Level Indicator / Controller Etc. Within Plant Room. Note: A ) .Contractor Shall Ensure Submission Of Detailed Civil General Arrangement Drawings ( Plan & Section ) , P & I ( Programming & Instrumentation ) Diagram, Schematic Diagram For The Above Mention Component & Additional Component Such As Inserts, Puddle Flanges, Vent Pipes Etc. If So Required For The Complete Working Of The Stp And Got It Approved By The Engineer In Charge. B ) .Only Plateform For Stp Plant Shall Be In The Scope Of The Owners. The Sewerage Treatment Contractor Shall Co-Ordinate, Supervise And Get All The Inserts Installed. All Supply Of Ms / Insert Plates Shall Be In The Scope Of The Sewerage Treatment Contractor.Supply, Installation, Testing & Commissioning Of 2 Nos Mild Steel 5Mm Frp Coatingperforated Corrugated Bar Screen With Vertical Grating Made By 3 Mm Thick Stainless Steel Plate, Spacing Of Plates 20 Mm C / C Both Sides With Suitable Lifting Arrangement ( Size 750 Mm Wide X 600 Mm High Approx ) C ) .Supply, Installation, Testing & Commissioning Of 2 Nos Mild Steel 5Mm Frp Coatingperforated Corrugated Bar Screen With Vertical Grating Made By 3 Mm Thick Stainless Steel Plate, Spacing Of Plates 20 Mm C / C Both Sides With Suitable Lifting Arrangement ( Size 750 Mm Wide X 600 Mm High Approx ) D ) .Supply, Installation, Testing And Commissioning Of The Following Tanks And Chambers In Hdpe / Pvc As Per Approved Drawings And Directions Of Engineer Incharge. The Cost Shall Include All The Required Mswalking Platform, Handrail, Staircase, Manhole Cover Etc. All Above Quoted With Minimum 10Mm M.S Tanks With 5Mm Frp Coating Protectiona ) .Mbbr Tank Of Capacity 25000 Litersb ) .Tube Settler Tank Of M Sc ) .Sludge Holding Tank Of Capacity 5000 Litresd ) .Chlorine Contact Tank Of Capacity 10000 Litrese ) .Treated Water Tank Of Capacity 15000 Litres Quoted With Minimum 10Mm M.S Tanks And All Above Item As Per Design Requirments ( No Extra Payment Shall Be Paid ) 90 Supply, Installation, Testing & Commissioning Of Horizontal Type Pumps, Having Cast Iron Body, C.I. Impeller & Shaft Connected To Tefc Motor For 415 Volts, 3 Phase, 50 Cycles A.C. Power Supply Withmechanical / Gland Seal. Protection Complete In All Respects Including Suction And Delivery Headers With Upvc Pipe Of Required Dia, Isolation Valves, Nrv & Pumps Shall Have Following Duty: A ) .Raw Sewage Transfer Pump ( Pumps To Be Suitable To Handle Solid Handling Capacity Upto 40 Mm Size ) Set Of Two Pumps ( 1 Working + 1 Standby ) Capacity - 2.5 Lps ( Required- 2.5M3 / Hr ) Head - 10-12 Mtr.H.P.-2 Hp Approx. 91 B ) .Submersible Sewage Lifting Pumpset Of Two Pumps ( 1 Working + 1 Standby ) Capacity - 1.5 Lpshead - 10-12 Mtr.H.P.-2 Hp Approx. ( Solid Handling Capacity Upto 40 Mm Size ) 92 Supply, Installation, Testing & Commissioning Of Electromagnetic Type Flow Meter At The Outlet Point Of Raw Sewage Transfer Pump Of 50 Mm Size Suitable For 0 - 15 Klh Flow. 93 Supply, Installation, Testing & Commissioning Of Twin Type Rotary Air Blower With Acoustic Encloser, Driven Through “V” Belt Or Directly Coupled Through Flexible Coupling To A Tefc Motor Of Suitable Hp Suitable For 415 ± 10% Volts, 3 Phase, 50 Cycles A / C Supply. Capable Of Delivering 70 Cum / Hr Of Free Air At 0.5 Kg / Cm2. 94 Supply, Installation, Testing & Commissioning Of Air Piping Shall Comprise Of Pipes Droppers / Laterals With Ms ( Epoxy Coated ) Header Complete With All Fittings Such As Tees, Crosses, Plugs, Sockets, Elbows, Reducers, Supports & Clamps, Puddle Flanges Etc Including Cutting Holes In Wall, Makes Chases In Wall And Making Good The Same. Contractor To Submit Detailed P&I Indicating Their Proposal. 95 Supply, Installation, Testing & Commissioning Of Fine Air Diffusers Capable Of Delivering 10-12 Cum / Hr In Mbbr Tank For Providing Areation. 96 Supply, Installation, Testing & Commissioning Of Coarse Air Diffusers Capable Of Delivering 3-6 Cum / Hr In Equalization Tank And Sludge Holding Tank For Providing Areation. 97 Supply, Installation, Testing And Commissioning Of High Surface Area @ 400 M2 / M3 At Least Ring Type Media To Be Used For Bacterial Growth Installed In Moving Bed Bio Reactor Tanks. 98 Supply, Installation, Testing And Commissioning Of Pvc Tube Deck Settling Media To Be Installed In Tube Settling Tank. The Media To Be Supported On Msep Frame With Baffle Plate & Overflow Launder. 99 Supply, Installation, Testing And Commissioning Of Single Stage Horizontal Centrifugal Self Priming Pump With With C.I Body, Bronze Impeller, Shaft Of Stainless Steel, Shaft Sleeve Of Chrome Steel And Delivery Casing In C.I With Mechanical Seal, Connected To A Tefc Inductionmotor Suitable For 415+ / - 10%Volts, 3Phase50 Cycles A.C. Supply With 150Mm Dia Pressure Gauge With Gunmetal Isolation Cock, Vibration Eliminating Pads Under Foundation, Sequence Running Controller, Dry Running Protection, 80X40 Mm I Section Base Plate Bolted To Cement Concrete Foundations Complete Includingisolation Valves, Nrv & Vibration Eliminators On Both Suction & Delivery Side Of Pumps .Vendor To Submit Performance Curves And Technical Catalogue Of The Proposed Model For Review And Information. A ) .Sludge Feed / Transfer Pump ( Pumps To Be Suitable To Handle Solid Handling Capacity Upto 8-10 Mm Size ) B ) .Set Of Two Pumps ( 1 Working + 1 Standby ) C ) . Capacity- 1.5 Lpsd ) .Head - 10.0 Mtr. E ) .H.P.-1.5 Hp Approx. 100 Supply, Installation, Testing And Commissioning Of Horizontal Centrifugal Pumping Set With Cast Iron Body, Bronze Impeller, Shaft Of Ss And C.I. Base & Head With Mechanical Seal, Connected To A Tefc Inductionmotor Suitable For 415 + / - 10%Volts, 3 Phase 50 Cycles A.C Supply With 150Mm Dia Pressure Gauge With Gunmetal Isolation Cock, Vibration Eliminating Pads Under Foundation, Dry Running Protection, 80X40 Mm I Section Base Plate Bolted To Cement Concrete Foundations Complete Including Isolation Valves, Vibration Eliminators On Both Suction & Delivery Side Of Pumps And Nrv On Delivery Side Of Pumps Vendor To Submit Performance Curves And Technical Catalogue Of The Proposed Model For Review And Information.A ) .Filter Feed Pumpsb.Set Of Two Pumps ( 1 Working + 1 Standby ) C ) .Capacity- 3.0 Lps ( Suggested And Quoted For 5000Lph ) D ) .Head - 30.0 Mtr.E ) .H.P.-3.0 Hp Approx. 101 Supply, Installation, Testing & Commissioning Of Vertical Self Supporting Filtration Unit Fabricated From Ms Sheet As Per Is: 2825 ( Minimum Thickness Of Shell 8 Mm And Dished Ends 10 Mm ) Pressure Gauges, Sample Cock, Gi Class C Face Piping, Ci Butterfly Valves And All Accessories, With Initial Charge Of Filter Media Including Anthracite, Painting Inside With Epoxy Paint And Outside With Two Coat Of Red Oxide Primer And Two Or More Coat Of Synthetic Enamel Paint, Testingand Commissioning Complete.A ) .Mulitgrade Pressure Sand Filtercapacity - 5000 Lph Filtration Rate -14000Lph / Sqm Filter Dia Approx. - 800 Mm Working Pressure: 3.0 Kg / Sqcm. Test Pressure : 4. 5 Kg / Sq Cm 102 B ) .Activated Carbon Filter Filtration Rate -14000Lph / Sqm Filter Dia Approx. - 800 Mm Working Pressure: 3.0 Kg / Sqcm.Test Pressure : 4. 5 Kg / Sq Cm 103 Supply, Installation, Testing & Commissioning Of Metering Pump Type Chemical Doser With 100 Lits. Pvc / Hdpe Solution Tank, Injection Fitting Assembly, Suction And Delivery Hose Upto The Point Of Injection, Capacity 0-6 Lph, Complete In All Respects. 104 Supply, Installation, Testing & Commissioning Of Ultravoilet Dis-Infection Unit. The Unit Shall Have Over 99.9 % Bacterial Reduction From Inlet To Outlet. The Dis-Infection Chamber Shall Be Constructed Of Ss 316L On All Welted Parts. The Uv Lamp Shall Be Of Low Pressure Mercury Vapour Type With Hard Glass Enclosure, The Sockets Shall Be Water Tight & Vibration Resistant. The Lamp Life Shall Be Rated For 6000 Hours. The Unit Shall Be Complete With Temperature Safety Control, Lamp Out Alert Circuit & Uv Radiometer With 4 – 20 Ma Output. The Uv Unit Shall Have With Reactor, Cabinet Housing, Cabinet Cooling, Treatment Chamber, Electrical Panel, Temperature Safety Control, Lampout Alert, Uv Radiometer Along With Uv Monitoring System And Uv Monitoring Readout Panel.The Uv Dosage Should Be > 60, 000 Uw – Sec / Sq.Cm. The Lamps Should Be Selected Based Upon The Flow Requirement Of Respective Unit.Flow Rate : 5 Cum / Hr 105 Supply, Installation, Testing & Commissioning Of All Pipings ( As Described Below ) And Isolation Control Valves Including All Necessary Fittings And Clamps, Supports, Hangers As Required I / C Cutting And Making Good The Walls Wherever Required Complete In All Respects For Making The System Complete.A ) .Gi : Submerged Air Piping ( We Suggest Upvc. Gi Is Never Used For Submerged Piping ) Ms Epoxy: Air Piping & Pumped Effluent Riser ( Non-Submerged ) Upvc : Interconnecting Pipe Line After Delivery Header Of Pump / Filtercontrollers With Low Voltage Relays, Stainless Steel Probes And Pvc Shroud, Control Cabling As Required Length. ( No Of Probes As Required For Function Of Each Controller ) . 106 B ) .Filter Feed Pumps To Cut Off Duty Pump On Low Water Level In The Chlorine Contact Tank And High Water Level In The Treated Water Tank And To Start Pump At Low Water Level In The Treated Water Tank. 107 Supply, Installation, Testing & Commissioning Of Filter Press Of Plate Size 18X 18X 12 Nos. Plate With Screw Feed Pumps Of 5 M3 / Hr @ 40 M Head Capacity ( 1 Working + 1 Standby ) Complete In All Respects. 108 Providing Installing Testing And Commissioning Of Ultra Filteration ( Uf ) System For Further Polishing Treated Effluent And Capable Of Producing 5, 000 Litre / Hour. The System Shall Be Complete With Uf Feed Pumps ( 1W+1S ) , Backwash Pumps ( 1W+1S ) , Cartridge Filters ( Fabricated| ) , Uf Membranes Flushing / Cleaning System Complete Instrumentation For Automation And Monitoring Rotameters Pressure Gauges Interconnecting Pipeword Electrical Cabling And Switchgear, All Complete Electrical Installation For Stp 109 Design, Fabrication, Assembling, Wiring, Supply, Installation, Testing And Commissioning Of Motor Control Centre Fabricated Out Of 14 Gauge Crca Sheet Steel. Cable Gland Plates Shall Be Provided On Top As Well As At The Bottom Of The Panels. Panels Shall Be Treated With All Anticorrosive Process Before Painting As Per Specifications With 2 Coats Of Red Oxide Primer And Final Approved Shade Of Powder Coated Paint. 2 Nos. Earthing Terminals Shall Be Provided For 3 Phase, 4 Wire, 50 Hz Supply System. Lifting Hooks Shall Also Be Provided In Case Of Large Panels. Approval Shall Be Taken For Each Panel Before Fabrication. Quoted Rates Shall Be Inclusive Of Cables ( In Accordance To Specification ) With Earthing From Panel To Each Motor / Equipment.Motor Control Centreincoming: A ) .200 Amps Tpn Mccb With The Following Accessories:B ) .0-500 Volts 96 X 96 Mm Square Electronic Voltmeter With Selector Switch Shall Be Protected By 2 Amps Tp Mcb. 1 Set.C ) .0-100 Volts 96 X 96 Mm Square Electronic Voltmeter With Selector Switch And Shall Be 100. / 5 Amps 10 Va Cl: Cts. 1 Set. D ) .Pharse Indicating Lamps Shall Be Protected By 2 Amp Sp Mcb 3 Sets. Bus Bar:A ) .200 Amps Tpn ( 15 Ka ) Copper Bus Bar With Heat Shrinkable Insulation Sleeves.Outgoing; A ) .10 Nos. Of 25 Amp Capacity Tpn Mcb With 10 Nos. Dol Starters And Out Going Feeders To All The Pumps Etc. ( Including Standbies ) . Each Compartment Shall Contain Auto / Manual Selector Switch Andindicating Lamp With Mcb’S For ‘On / Off / Trip’ Status Of Motor B ) .Spare 25 Amps TpnmcbS2 Nos. C ) .Spare 32 Amps TpnmcbS2 Nos. D ) .Necessary Cable Alleys, Internal / Cabling, Wiring, Cabling From Mcc To Various Pumps / Equipment And Interlocking, Earthing For All Equipment Shall Also Included Mcc For All Stp Equipments / Pumps As Described Above.Notes : A ) .All Mccbs / Mcbs Shall Be Of 15 Ka Breaking Capacity And Suitable For Motor Duty Application.B ) .All Motor Starters Shall Be Provided With Automatic Level Controller. C ) .Dol Starters Shall Be Used For Motors Below 10Hp And Star-Delta Starters For Other Motors . Motor Control Centre Incoming 200 Amps Tpn Mccb With The Following Accessories:0-500 Volts 96 X 96 Mm Square Electronic Voltmeter With Selector Switch Shall Be Protected By 2 Amps Tp Mcb. 1 Set.0-100 Volts 96 X 96 Mm Square Electronic Voltmeter With Selector Switch And Shall Be 100. / 5 Amps 10 Va Cl: Cts. 1 Set.Phase Indicating Lamps Shall Be Protected By 2 Amp Sp Mcb 3 Sets.Bus Bar 200 Amps Tpn ( 15 Ka ) Copper Bus Bar With Heat Shrinkable Insulation Sleeves.Outgoing10 Nos. Of 25 Amp Capacity Tpn Mcb With 10 Nos. Dol Starters And Out Going Feeders To All The Pumps Etc. ( Including Standbies ) . Each Compartment Shall Contain Auto / Manual Selector Switch Andindicating Lamp With Mcb’S For‘On / Off / Trip’ Status Of Motorspare 25 Amps TpnmcbS2 Nos. Spare 32 Amps TpnmcbS2 Nos. Necessary Cable Alleys, Internal / Cabling, Wiring, Cabling From Mcc To Various Pumps / Equipment And Interlocking, Earthing For All Equipment Shall Also Included Notes : All Mccbs / Mcbs Shall Be Of 15 Ka Breaking Capacity And Suitable For Motor Duty Application.All Motor Starters Shall Be Provided With Automatic Level Controller.Dol Starters Shall Be Used For Motors Below 10Hp And Star-Delta Starters For Other Motors .Provision Shall Be Made For Providing Potential Free Contacts To All Pumps Starters.Mcc For All Stp Equipments / Pumps As Described Above. Sub Total Of Part A 110 Part B ( O & M Cost ) ( For 5 Years ( 60 Months ) From Final Handing Over Of All Works. ) ( Optional ) Trained Operator To Operate The Stp Round The Clockincluding Operator And Regular Visit Of Supervisor. Perannum Including All Charges Like Amc , Monthly Charges Of Water Analysis And All Consumables Etc Included. Sub Total Of Part B ( Rate Only ) 111 Part:C Providing & Laying Upvc Pressure Pipes Of 6 Kg / Sq.Cm Pressure Rating Class 3 ( Is : 4985-2000 ) Including Fittings, Tees, Bends, Clamps, Coupling And Adaptors Supports, And Jointing With Solvent Joint, Testing And Necessary Earth Work In Excavation, Backfilling, Disposal Of Surplus Earth With A Lead Up To 100M Complete, Compaction And Consolidation Including Sand Bedding All Around Upvc Pipe & Fittings And Thrust Blocks At Bends As Per Standard Design.200Od 112 Constructing Rccchamber Of Holding Capacity 10 M3 With Grade Of M25 Including Cost Of Centering , Shuttering & Pcc Below Foundation In 1: 5:10 & 75 Mm Thick And Inside Chamber Of 75Mm Thick As Per Standard Design Including Inside Plastering With Cement Mortar 1:6 ( 1 Cement :6 Coarse Sand ) 12 Mm Thick Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design .Rate To Include Cost Of Reinforcement , Excavation And Filling Of Earth. Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) , Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. The Contractor Has To Detect Different Unilities Like Sewer Line , Water Supply Line , Electrical Cable , Telephone Cable , Gas Pipe Line Etc. Using Utility Detecting Machine Before Start Of Excavation And Shall Start Excavation Only After Getting Permission Of Engineer In Charge.All Kinds Of Soil.Depth Upto 1.5M From Existing Ground Level 113 B ) Filling Available Excavated Earth ( Excluding Rock ) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Upto 1.5 M. 114 Providing & Laying Cement Concrete - All Works Upto Plinth Level : C ) 1:4:8 ( 1 Cement : 4 Coarse Sand ( Zone-Iii ) : 8 Graded Stone Aggregate 40 Mm Nominal Size ) 115 Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, Including Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-In-Charge. ( Note :- Cement Content Considered In This Item Is @ 330 Kg / Cum. Excess / Less Cement Used As Per Design Mix Is Payable / Recoverable Separately ) . A ) Uptoplinth 116 Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level.B ) Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More 117 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For : C ) Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete 118 D ) Suspended Floors, Roofs, Landings, Balconies And Access Platform 119 Brick Work With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 10 In Foundation And Plinth In: A ) Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) For 230Mm Thick Brick Work 120 B ) 12 Mm Cement Plaster Of Mix :1:4 ( 1 Cement: 4 Fine Sand ) 121 C ) 15 Mm Cement Plaster On Rough Side Of Single Orbrick Wall Of Mix:1:4 ( 1 Cement: 4 Fine Sand ) 122 D ) 6 Mm Cement Plaster Of Mix :1:3 ( 1 Cement : 3 Fine Sand ) 123 Designing, Preparation Of Shop Drawings, Supplying, Erection, Testing, Commissioning Of All Mechanical, Electrical And Other Components Including Getting Approval Of Successful Test Results From Approved / Authorized Agency From Pollution & Environmental Authorities, Operating & Maintaining Upto Successful Commissioning, For 5 M3 / Day Capacity Sewage Treatment Plant Sewage Treatment Plant Near Workshop Area ( Complete System To Be Compact Type, Skid-Mounted / Cabinet Enclosed, As Per Detailed Shop Drawings To Be Approved ) Suprime / Sintex Maketotal C / F To Summary 124 R.O Water Treatmentplant: Supply, Installation, Testing And Commissioning Of R.O. Plant Capacity Of 750 Lph ( Complete System To Be Compact Type, Skid-Mounted / Cabinet Enclosed, As Per Detailed Shop Drawings To Be Approved ) For The Following Parameters And Consisting Of ( But Not Limited To ) The Following Main Components:- ( I ) Inlet Quantity : As Per Detailing ( Ii ) Output Quantity : 750 Lph ( Iii ) Inlet Tds : 600 Ppm ( Iv ) Outlet Tds : 75 Ppm ( V ) Inlet Hardness : 350 Ppm ) ( Vi ) Outlet Hardness : 50 Ppm ) Raw Water Pumps Of Horizontal, Centrifugal Type Suitable For A Flow Rate Of 1500 Lph At 25M Head. The Pump Construction Shall Be Of Ss-304 & Impeller Shall Be Also Ss-304. The Motor Shall Be Tefc Suitable For A Supply Of 415V / 3-Phase / 50Hz Supply. The Pump Shall Be Supplied Complete With Base Channel Coupling Foundations, Bolts, Pressure Gauge At Inlet And Outlet Of Each Pump. -- 2 Nos. ( 1W+1S ) Special Antiscalant Dosing System Consisting Of One Hdpe Tank Of 100 Litre Capacity With A Positive Displacement Diaphragm Dosing Pump Having Variable Flowrate Of 0-6 Lph. The Motor Shall Be Suitable For Operation At 240V / Single Phase / 50Hz Supply. The Pump Shall Be Supplied Complete With Necessary Polypropylene Piping, Valves, Strainers & Injection Fittings. -- 1 Set Micron Cartridge Filter Suitable For A Flowrate Of 1500 Lph To Achieve Particle Filtration Of Less Than 5 Microns. The Unit Shall Be Supplied Complete With Inlet And Outlet Branches Removal Cap For Replacement Of Element, Inlet And Outlet Pressure Indicators. ( One For The Pressure Treatment & Other For Cip System ) Moc: Polypropylene -- 2 Sets R.O High Pressure Feed Pumps Of Vertical, Multistage Centrifugal Type Suitable For A Flowrate Of2000 Lph At 14 Kg / Sq.Cm. The Pump Construction Shall Be Of Ss-316-L & Impeller Shall Be Also Ss-316-L. The Motor Shall Be Of Tefc Suitable For A Supply Of 415V / 3 Phase / 50 Hz Supply. The Pump Shall Be Supplied Complete With Base Channel Coupling Foundation, Bolt, Pressure Gauge At Inlet And Outlet Of Each Pump.- 2 Nos.R.O. Modules Made Out Of Spiral Wound Thin Film Composite Suitable To Withstand Pressure Of 20Kg / Sq.Cm. Suitable Bspt / Npt Connections Shall Be Used For Connecting Feed & Reject Ends. The Modules Shall Be Supplied Complete With All Necessary Instrumentation, Valves For Sampling, Drain, Reject & Permeate, Epoxy-Coated Structural Steel Bases And Supports, As Per Following System Capacity Requirements: ( I ) Total Net Treated Water Output Of System = 750 Lph ( Ii ) System Recovery= 50 - 60 % ( Iii ) Filtration Area Per Membrane = 85 Sq.Ft. ( Iv ) Number Of Membranes = The Total Number Of Membranes Required Shall Beas Per Requirements, Supported By Calculations From The Vendor. Centralised Plc Control Panelalong With Touch-Screen Digitial Display Board Along With All Digital Sensors For Tds & Flow, Made Out Of Crca Sheet Min. 2Mm Thick Having Main Contactors For All Pumps ( Listed Above ) Including Spp, 3 Phase Thermal Overload Relay. The Control Panel For Monitoring And Control Of P.O. System Shall Include All Required Signal Lamps, Hrc Fuses, Annunciation Box With Hooter. All Control And Power Cabling Along With Double Earthing Between The Panel Shall Be Included In The Scope Of Supply Of The Contractor. An Emergency Stop Push Button Shall Be Provided In The Panel. The Mcc Panel Shall Have The Following Interlocks:- I ) High Pressure Pump Unit Trip In Case Of Low Suction Pressure. Ii ) High Pressure Pump Unit Trip In Case Of High Discharge Pressure.Iii ) Special Anti-Scalant Dosing Pump Trips In Case High Pressure Pump Trips And Vice Versa.Iv ) High Pressure Pump Trip In Case Of High Conductivity In Permeate.V ) Shc Dosing Pump Trips Incase High Pressure Pump Trips And Vice Versa. Vi ) Orp With Dump Valve.-- 1 Seti ) First Fill Of All Chemicals And Lubricants To Commission And Operate The Plants. --1Lotj ) All Interconnecting Piping Work With Valves:- I ) Low Pressure Side Till R.O. Feed Water Pump. Piping Shall Be Of Extra Strong Pvc And All Valves Shall Be Of Extra Strong Pvc And All Valves Shall Be Pvc Ball Valves. -- 1 Lotii ) High Pressure Side Piping From The R.O. High Pressure Pumps To The Reject Stream Control Valves Shall Be Of Ss - 304 Using All Ss Fittings Ball Valves Of Suitable Pressure Rating Shall Be Used Till 25 Mm Size, Above 25 Mm, Flanged Globe / Wafer Butterfly Valves In Ss Construction Shall Be Used. Rejects Pressure Control Valves Shall Be Globe Valve And Feed Flow Control Valve Shall Be Of Ss-304. -- Lotiii ) Before Procurement Of Material Contractor Should Be Get Technical Approval From Consultants. ( All For Above From A To J Complete ) 125 R.O Water Storage Complete 316 Stainless Steel Treated Water Storage Tank ( Double Wall ) Of Capacity 2000 Litres Including All Inlet / Outlet Connections, Accessories, Valves, Double Seal Manhole Covers, Insulation Etc.The Stainless Steel Tank Must Be Ozone Resistant And To Be Used As Ozone Contact Tank. Fabrication To Be Done As Per Approved Shop Drawing. ( Make :Nector ) 126 Providing And Placing On Terrace ( At All Floor Levels ) Polyethylene Water Storage Tank, Is : 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflowpipes But Without Fittings And The Base Support For Tank.. 127 Activated Carbon Filter ( Automatic Type For Online Installation Before The Micron Filters ) Suitable For A Flow Rate Of 1500 Lph. The Material Of Construction Shall Be Composite Frp. The Unit Shall Be Supplied Complete With Multi-Port Valves, Inlet And Outlet Branches Removal Caps Of Replacement Of Elements Inlet And Outlet Pressure Indicators. -- 1 Set 128 Hydropneumatic System For R.O Supply Providing Fixing And Commissioning Suitable Complete Composite Hydropneumatic System Consisting Ofhorizontal / Vertical Multistage Centrifugal Pump Having Stainless Steel Impellers, Stainlesssteel Shaft, Stainless Housing And Single Mechanical Seal And Pressurised Tankof Required Specifications And Of Non-Toxic Rubber Diaphragm, Complete With All Accessories Including Pressure Switch, Pressure Gauge And Electrical Panel With All Necessary Protection And Operational Devices I.E Alternate Pumping Operation And Shut Off During Dry Running Conditions Etc., And Inclusive Of Ss 316 Suction And Delivery Manifold Of Required Size With Non-Return Valve And Ball Valveand Withsuitableelectrical Motor To Be Operated On 210 / 220 Or 400 / 440 Volt 50 Cycle Suitable For Following Duty And With Total No. Of Pumps - 2 Nos. ( 1 Working+ 1 Standby ) Complete With The Approval Of Engineer-In-Charge.- Before Procurement Of Material Contractor Should Be Get Technical Approval From Consultants.A ) Discharge:150 Lpmb ) Head:45 M C ) App. Capacity Of Thevessel ( Frp ) : As Requiredtotal C / O To Summary 129 Hot Waterboilers And Other Related Accessories Electrical Hot Water Generators System With Solar Back Up.Hot Water Mixing Storage Tank ( 2 Sets For Club And Benquet Hall ) Supply, Installation, Testing And Commissioningof Solarwater Heating System Capable Of Generating 7500Lpd Of Hot Water Per Day At 60 Oc Along Withinsulated Horizontalhot Watermixing Tank Capacityand Design Code I.S: 2825 Fabricatedof 6 Mm Thick S.S. 304Plateand 10 Mmthickdishedend And Nozzles Complete With Inlet, Cold Waterinlet / Outlet Chain Connection Withflanges, Manhole With Bolted Cover With 72 Kw Electrical Back Up Along With Control Panels . Tankshall Beinsulated With 50 Mm Thickresin Bondedfibre Glass ( Density 24 Kg / Cum ) And Covered With500gpolythene Sheetand 24 Gauge Aluminumsheet Cladding Giving Proper Overlaps And Sealing The Joints With Suitable Adhesive Compound, Including The Following Additional Accessories / Specifications:Working Pressure : 7.5 Kg / Cm²i ) Safety Valveii ) Dial Type Thermometer Iii ) Thermowell For Thermostat Elements Cold Water Inlet Valve 80 Mm Dia Check Valve In Cold Water Inlet 80 Mm Dia.Hot Water Inlet / Outletsecondary Side 50 Mm Dia Valve Plate Type Heat Exchanger Compleate With Pumps Required Specification.Hot Water Outlet Connection Valve To System 100Mm Diaplate Type Heat Exchanger Compleate With Pumps Required Specification.Hot Water Outlet Connection Valve To System 100Mm Dia Hot Water Return Inlet 65 Mm Dia Drain Valve 50 Mm Diaair Release Valve 25Mm Diahot Water Return Nrv 65 Mm Dia Solar Pre Heating Working Inlet 80 Mm Dia Butterfly Valvesolar Pre Heating Working Inlet 80 Mm Dia Nrv Electrical Control Panel As Per Approved Apecification Temp. Controller 130 Hot Water Returnpumps For Domestic Waterprovidingand Fixing Horizontal Multistage Centrifugal Pumping Set With Stainless Steel Ss-304 Stage Casing And Ss-304 Impellers With Stainless Steel Ss-304 Shaft As Per Iec Standards Andss - 304 Suction & Discharge Casing, Connected To Tefc Ventilated Induction Motor Of 2 Pole, 2900 Rpm, Suitable For 400 / 440 V Phase, 50 Hz A.C. Supply With Pressure Gauge And With Gunmetal Isolation Cocks, Vibrationelimination Pads Etc. Complete With Base And Frame, Nuts & Bolts And Necessary Rcc Foundations As Per Requirement As Per Instructions And Pump Shall Follow Following Dutynos : 2 ( 1 W +1 S ) Capacity: App.100 Lpm Head :15 M 131 Solar Hot Water Re-Curculation Pumps : Providingand Fixing Horizontal Multistage Centrifugal Pumping Set With Stainless Steel Ss-304 Stage Casing And Ss-304 Impellers With Stainless Steel Ss-304 Shaft As Per Iec Standards Andss - 304 Suction & Discharge Casing, Connected To Tefc Ventilated Induction Motor Of 2 Pole, 2900 Rpm, Suitable For 400 / 440 V Phase, 50 Hz A.C. Supply With Pressure Gauge And With Gunmetal Isolation Cocks, Vibrationelimination Pads Etc. Complete With Base And Frame, Nuts & Bolts And Necessary Rcc Foundations As Per Requirement As Per Instructions And Pump Shall Follow Following Duty Nos : 2 ( 1 W +1 S ) Capacity: App100 Lpm Head :55 M 132 Electrical Panel Providing Motor Control Centres Fabricated From 16 Gauges M.S. Sheet With Powder Coated Finish. The Control Panels Should Be Comparable With H.P. Of The Motor As Specified.For Hot Water , Steam Genration Systemshot Water Recuculation Pumps, Hot Water Supply Pumps Condensate Pumps Etc.A ) One Incoming Main Isolation Mccb Of Required Rating.B ) Fully Taped Aluminum Bus Bar Ofrequiredcapacity In A Separate Bus Bar Chamber.C ) Isolation Switch Units With Mccbof Required Rating, For Each Unit.D ) Fully Automatic Dol Starter With Pushbutton And On / Off Indicating Lights For Each Unit, For Following Requirements:I ) Hot Water Boilers 2 Nos. Of Required 74 Kw Eachii ) Hot Water Re-Circulation Pumps 2 Nos. ( 1 Working+ 1 Stand By ) Of Required Hp Iii ) Solar Hot Water Recirculation Pumps 2 Nos. ( 1 Working+ 1 Stand By ) Of Required Hpiv ) One No. Spare Feeder Required 5 Hprotary Switches For Auto / Manual On / Off Operations For Each Unit.Rotary Duty Selector Switches.Panel Type Voltmeter 150Mm With Rotary Selector Switch For Reading Voltage Between Phases.Neon Phases Indicating Lights On The Incoming Mains. Single Phasepreventorfor Each Motor. Ct Operated Relayall Internal Wiring Colour Coded From Incoming Mains To Various Switchgear, Starter, Meter, Indicating Lamp And Bus Bar. All The Cable Entry To The Panel Shall Be From The Top. ( All For Above From Item ( A ) To ( L ) Complete Set ) . ( The Shop Drawing To Be Preparedand Approved Before Fabrication ) Total C / O To Summary 133 Swimming Pool Filteration System Recirculation Pumps Main Pool + Jacuzziarea : 550 M2 X 1.2 M Balancing Tank : 60 M3total Pool Volume : 660 M3 + 60 M3 = 720 M3filtration Flow Rate : 180M3 / Hr Filtration Plant With Pumpsupply, Instalation, Testing & Commissioning Of Bobbin Wound Side Mount Sand Filter Manufactured With Fiber Glass And Polyester Resin, Uv Resistance Surface, Fitted With Collector Arms And Diffuser Made From Unplasticised Pvc And Polypropylenewith Lid In Polyester Resin And Fibre Glass, Manual Air Purgeand 4 Pvc Flanged Connection For Inlet And Outlet, Pressure Gauge, Water Drain / Empty Drain For Filter Etc.Complete In All Respects. Including Corse & Fine Silica Sand Media For Filterapx. 7200Kgcapacity 60000 Ltrs / Hrdesign @30000 Ltrs / Sqm / Hr.Diameter1600 Mm Working Pressure4.0 Kg / Cm² 134 Valve Battery Valve Battery Manifold Made In Pvc With Flanges For Connecting To Filters Consists Of Set Of 5 - Buttterfly Valves For Carrying Out Filtration, Back-Washing, Rinsing And Shut Down Of The Filters. Size : 4 Inchsupply, Instalation, Testing & Commissioning Of Self Primingpumps With Ci Body, In Built Ci Strainer Basket, Impeller In Ci / Bronge, Motor Shaft In Stainless Steel Aisi-420, Mechanical Seal In Sic - Sic / Carbon - Ceramic, Motor Housing In Aluminium, Withmotor -2850Rpm, F Class Insulation, Protection Ip-55. ( 3W+1S ) 135 Supply, Instalation, Testing & Commissioning Of Self Primingpumps With Ci Body, In Built Ci Strainer Basket, Impeller In Ci / Bronge, Motor Shaft In Stainless Steel Aisi-420, Mechanical Seal In Sic - Sic / Carbon - Ceramic, Motor Housing In Aluminium, Withmotor -2850Rpm, F Class Insulation, Protection Ip-55. ( 3W+1S ) Capacity60000 Ltrs / Hrhead 16 Mtrhp 7.5, Three Phase 136 Swimming Pool U.V. Sterlizersupply, Instalation, Testing & Commissioning Of U.V. Sterlizer With S.S. Housing Outside, U.V. Lamp, Glass Tube And All Other Accessories With Cleaning Arrangement, Supports, Inlet Outlet Connection With Bypass Arrangement Including S.S. Cabinet With Glass Door Of Suitable Size To House The U.V. Sterlizer Complete With Required Accessories. Flow Rate = 60000 Ltr / Hrworking Pressure = 4.0 Kg / Sqm Uv Lamp Wattage = 400 W 137 Dosing Pumpsupply, Instalation, Testing & Commissioning Of Chemical Dosing Pumpfor Chlorination With 200 Ltrs. Sintex Tank And Accessories Capacity0-20 Litres / Hr.Head35 M 138 Stainless Steel Drain Supply, Instalation, Testing & Commissioning Ofstainless Steel Drain Grating Plate Made Out Of 316 Quality S S Plates With Suitable Supporting Frame And Of Following Sizes And Having Holes Of Required Size For Drainout Chamber.Size 400X400 Mm 139 Inlet Nozzlesupply, Instalation, Testing & Commissioning Of Flow Adjastable Abs Inlet Nozzles Uv Treated With S.S. Screws To Fit In The 2 Pvc Pipes 140 Suction Inlets ( Vacuum Points ) Supply, Instalation, Testing & Commissioning Of Abs White Plastic Suction Port / Vacuum Nozzle With 2 Inch Solvent Cement Connection 141 Supply, Instalation, Testing & Commissioning Of Stainless Laddersteel 316 Ladders, Width: 500Mm Wide, Handrails Dia 43Mm Stainless Steel, Non-Slip Stepsprovided With Anchoring Socket.A ) 3 Step Standard Ladder With Anti-Skid Steps 142 B ) 4 Step Standard Ladder With Anti-Skid Steps 143 Underwater Led Lights Supply, Instalation, Testing & Commissioning Of 12Volt 54 W Under Water Stainless Steel 316L Led Light Fixture ( Ip 68 ) Including All Required Assessories & Making Connection As Required. With 2 Mtr Power Cord. 144 Power Supply Supply, Instalation, Testing & Commissioning Oftransformer For Led Lights 12V Dc, 30 Amp 145 Deck Box Supply, Instalation, Testing & Commissioning Of Abs White Plastic Deck. 146 Cleaning Accessories A ) Extensivetelescopic Handle, ( 2.4 - 4.8 ) Metres Long &1.1Mm Thick For Cleaning Attachment In Anodized Almunium. 147 B ) Transparent Blue Polyethylene Hose 40Mm ( 1-1 / 2 ) Dia 30 M Length. 148 C ) Surface Net Skimmer Made In Polypropylne 149 D ) Deep Bag Net Skimmer Made In Polypropylne 150 E ) Curved Polybristle Wall Brush 450 Mm 151 F ) Test Kit For Ph And Chlorine. 152 G ) Hi-Grade Stainless Steel Algae Brush - 10 153 H ) Vacuum Head With Ss-Body, 1 1 / 2 Connection Size 900 Mm Long 154 I ) Deluxe Large Vacuum Head With 4 Wheels, Alu-Body, Plastic Handle, 1 1 / 2 Connection Size 445X130 Mm 155 J ) Polybristle Wall Brush 10 ( 26Cm ) 156 K ) Chemical Tcca 90 ( 50 Kg. ) & Alum ( 30 Kg. ) 157 L ) Nylon Rope 158 Upvc Pipesproviding And Fixing Upvc Pressure Pipes ( 10Kg / Cm2 ) With Plain Socket Suitable For Solvent Cement Jointing Conforming To Is:4985 / 2000 & Fittings Conforming To Is 7834 / 87.Cut To Required Lengths Including All Necessary Fittings And Specials Such As Bends, Tees, Unions, Reducers, Flanges And Plugs Etc. The Pipes & Fittings Shall Be Tested To A Pressure Of 10 Kg / Sq.Cm.A ) 32 Mm Dia 159 B ) 50 Mm Dia 160 C ) 63 Mm Dia 161 D ) 75 Mm Dia 162 E ) 90 Mm Dia 163 F ) 110 Mm Dia 164 G ) 160 Mm Dia 165 H ) 200 Mm Dia 166 I ) 250 Mm Dia 167 Ball Valveproviding And Fixing Pvc Lever Operated Ball Valve Of Full Flow With Setting And Gland Of Superior Quality Having Minimum Working Pressure Of 10 Kg / Cm2 With Union, Flanges Where As Required.A ) 32Mm Dia 168 40Mm Dia ( Rate Only ) 169 50Mm Dia ( Rate Only ) 170 63Mm Dia 171 75Mm Dia ( Rate Only ) 172 90Mm Dia ( Rate Only ) 173 Butterfly Valve Providing And Fixing Upvc Butterfly Valves. Tested To A Pressure Not Less Than10 Kg / Sq.Cm. Including Rubber Gasket, Flanges, Nuts, Bolts, Washers Complete As Required. A ) 90 Mm Dia 174 B ) 110 Mm Dia 175 C ) 160 Mm Dia 176 D ) 200 Mm Dia 177 E ) 250 Mm Dia 178 Non Return Valveproviding And Fixing Pvc Ball Type Or Spring Loaded Non Return Valve With Setting And Gland Of Superior Quality Having Minimum Working Pressure Of 10 Kg / Cm2 With Union, Flanges Where As Required.A ) 50Mm Dia 179 B ) 63Mm Dia 180 C ) 75Mm Dia 181 Providing And Fixing Of Upvc Wafer Check Valve Non-Return Valves ( Pn 10 ) Complete With Matching Flanges, Rubber Insertion, Nuts, Bolts And Washer Etc. Of Following Sizes.A ) 75Mm Dia 182 B ) 90 Mm Dia 183 C ) 110 Mm Dia 184 D ) 160 Mm Dia 185 E ) 200 Mm Dia 186 F ) 250 Mm Dia 187 Puddles Sleevesupply & Fixing Of Following Sizes Of Heavy Duty Pvc Puddle Flanges ( Upvc Pipe ( 10 Kg / Cm2 ) Fixed With Flanges, Length 400 To 600 Mm Length ) On The Wall Of Plantroom, Balancing Tank And The Water Body Walls & Slab ( As Required ) . To Be Laid In Between The Steel Reinforcement Before Rcc. Does Not Include Any Civil Work. A ) 32 Mm Dia 188 C ) 50 Mm Dia 189 D ) 63 Mm Dia 190 E ) 75 Mm Dia 191 F ) 90 Mm Dia 192 G ) 110 Mm Dia 193 H ) 160 Mm Dia 194 I ) 200 Mm Dia 195 J ) 250 Mm Dia 196 Supply, Laying, Testing And Commissioning Of Ss 304 Grade 300Mm Dia Pump Suction Header With 2 Nos 200Mm Dia Flange Connection For Balancing Tank To Pump Suction Header, 1 No. 90 Mm Dia Flange Connection For Vacuum Pipe & 1 No. 200 Mm Dia Flange Connection For Pool Drain Pipe & 4No. 200Mm Dia & 2 No. 160Mm Diaflange Connection For Pump Suction. 197 Supply, Laying, Testing And Commissioning Of Ss 304 Grade 200Mm Dia Pump Delivery Header With 1 Nos 200Mm Dia Flange Connection For Filter Inlet Header, 1 No. 160 Mm Dia Flange Connection For Drain Pipe & 4 No. 160Mm Dia Flange Connection For Pump Delivery. 198 Supply, Laying, Testing And Commissioning Of Following Size Pvc Insulated Sheathed Copperconductor 1100 V Grade Unarmoured Cable With Required Size Of Sleeves Complete As Required. A ) 4 X 16 Sq.Mm 199 C ) 4 X 6 Sq.Mm ( Rate Only ) 200 D ) 4 X 4 Sq.Mm ( Rate Only ) 201 E ) 4 X 2.5 Sq.Mm 202 F ) 4 X 1.5 Sq.Mm ( Rate Only ) 203 G ) 3 X 6 Sq.Mm ( Rate Only ) 204 H ) 3 X 4 Sq.Mm 205 I ) 3 X 2.5 Sq.Mm ( Rate Only ) 206 J ) 3 X 1.5 Sq.Mm ( Rate Only ) 207 K ) 2 X 6 Sq.Mm 208 L ) 2 X 4 Sq.Mm ( Rate Only ) 209 M ) 2 X 2.5 Sq.Mm 210 N ) 2 X 1.5 Sq.Mm 211 Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In 6 Gauge Gi Wire Recess For Loop Earthing As Required. 212 Supplying And Installing Following Size Of Perforated Painted With Powder Coating M.S. Cable Trays With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With M.S. Suspenders Including Bolts & Nuts, Painting Suspenders Etc As Required. A ) 300 Mm Width X 50 Mm Depth X 1.6 Mm Thickness 213 B ) 150 Mm Width X 50 Mm Depth X 1.6 Mm Thickness 214 Providing & Fixing M.S. Structural Work Fabricated From Standard Section E.G. M.S Rounds, Angles, Channels, Plates Including Cutting To Size, Drilling, Welding Fixing And Welding To Insert Plates In Rcc Structural Members As Directed By Engineer-In-Charge Including Cutting And Making Good The Walls, Ceilings And Floors ( For Pipe Supports, Clamps Etc. ) 215 Electrical Control Panel Supply, Installation, Testing And Commissioning Of Following Swimming Pool Panel 415 V, 1 / 3 Phase And 50 Hz Power Distribution System. Thepanel Shall Be Free Standing Floor Mounting Sheet Metal Enclosed Dust And Vermin Proof Confirming To Ip-54, Compartmentalized Design Fabricated Out Of 16 Swg Sheet Steel, Painting Earthing Numbering, Danger Plate As Per Specifications And Drawings. Flush Front With Aluminium Busbars, Seperate Earth Bus Bars To Be Provided Throughout The Length Of The Panel The Incoming And Outgoing Feeder Breakers, Fuses, Indicating Lamps Etc Shall Be Accomadated In A Modular Multilier Arrangement. The Panel Shall Be Powder Coated Through 9 Tank Process. Adequate Size Cable Alley Shall Be Provided Forcable Termination.The Outgoing Feeders Inside Shall Be Connected Through Bus Bars / Flexible Cable Links. Incoming: One ( 1 ) No. 200A Tp 25 Ka Mccb With Thermomagnetic Digital Flush Mounted 0-200A Ammeter With 3 Way And Off Selection Switch With 3 Nos. 200 / 5 Amp Ct. 1 Set ( 3 Nos. ) Of Phase Indication Lamps 200A 25 Ka Tpn Aluminium Bus Bar. It Shall Be Insulated With Heat Shrinkable Sleeves And Shall Be Color Coded. Outgoing: Recirculation Pumpsix ( 6 ) Nos. Star Delta Starter Complete With Separate Single Phasing Protection Feature. On / Off Indicating Lamps, Relay, Contractors, Start / Stop Push Button, Auto / Manual Selector Switch, Sufficient Nos Of Potential Free Spare Contacts, Etc For Suitable Hp3 Nos. 6Amp Dp Mcb Of Suitable Rating With Correct Thermal Range Suitable For Chemical Dosing3 Nos. Toggle Switch For Doser3 Nos. 6Amp Dp Mcb Of Suitable Rating With Correct Thermal Range Suitable For Uv 3 Nos. Toggle Switch For Uv 1 Nos.16Amp Dp Mcb Of Suitable Rating With Correct Thermal Range Suitable For Underwater Lights 1 Nos. Toggle Switch For Led Pool Lightstotal C / O To Summary 216 Entry Water Bodypressure Sand Filtersupply, Instalation, Testing & Commissioning Of Bobbin Wound Top Mount Sand Filter Manufactured With Fiber Glass And Polyester Resin, Uv Resistance Surface, Non Corrosive Material, Complete With 6-Way 2 Multiport Valve With Filter Connection / Inter-Connecting Piping, Pressure Gauge, Water Drain / Empty Drain For Filter.Including Corse & Fine Sand Media For Filter As Per Approved Calculation Capacity15000 Ltrs / Hr Design @35000Ltrs / Sqm / Hr. Diameter750 Mm 217 Filter Re-Circulation Pumpsupply, Instalation, Testing & Commissioning Of Self Primingpumps With Plastic Body, In Built Strainer Basket, Impeller In Ppo, Motor Shaft In Stainless Steel Aisi-420, Mechanical Seal In Sic / Graphite And Steatite, Motor Housing In Aluminium, Withmotor -2800Rpm, F Class Insulation, Protection Ip-55. ( 1W+1S ) Capacity15000 Ltrs / Hr Head 12 Mtrhp 2.0, Three Phase 218 Fountain Re-Circulation Pump Single Stage High Speed Horizontal Centrifugal Monobloc With Volute Type Delivery Casing Pool Recirculation Submersible Pump, Delivery Casing & Motor Body In Ci, Motorshafts In Carbon Steel, Impeller In Ci Withmotor Hp7.5, Three Phase 219 Single Stage High Speed Horizontal Centrifugal Monobloc With Volute Type Delivery Casing Pool Recirculation Submersible Pump, Delivery Casing & Motor Body In Ci, Motorshafts In Carbon Steel, Impeller In Ci Withmotor Hp2.0, Single Phase 220 Swimming Pool U.V. Sterlizer Supply, Instalation, Testing & Commissioning Of U.V. Sterlizer With S.S. Housing Outside, U.V. Lamp, Glass Tube And All Other Accessories With Cleaning Arrangement, Supports, Inlet Outlet Connection With Bypass Arrangement Including S.S. Cabinet With Glass Door Of Suitable Size To House The U.V. Sterlizer Complete With Required Accessories. Flow Rate = 20000 Ltr / Hrworking Pressure = 2.5 Kg / Sqmuv Lamp Wattage = 40 W 221 Chlorine Tablet Feedersupply, Instalation, Testing & Commissioning Of Chlorine Tablet Feeder With Accessories Capacity = 4.5 Kg 222 Stainless Steel Drain Supply, Instalation, Testing & Commissioning Ofstainless Steel Drain Grating Plate Made Out Of 316 Quality S S Plates With Suitable Supporting Frame And Of Following Sizes And Having Holes Of Required Size For Drainout Chamber.Size 200X200 Mm 223 Fountain Nozzlesupply, Instalation, Testing & Commissioning Of Brass Crome Plated Gyserjet Nozzle With 1 Connection With Required Accessories. 224 Suction Inlets ( Vacuum Points ) Supply, Instalation, Testing & Commissioning Of Abs White Plastic Suction Port / Vacuum Nozzle With 2 Inch Solvent Cement Connection 225 Supply Of12volt 12W Under Water Stainless Steel 316 Ring Underwater Led Lightstype Led Warm White Light ( Ip 68 ) Including All Required Assessories & Making Connection As Required. With 2 Mtr Power Cord.For Fountain Nozzle 226 Power Supplysupply, Instalation, Testing & Commissioning Oftransformer For Led Lights 12V Dc, 30 Amp 227 Supply, Instalation, Testing & Commissioning Ofrgb Programmer For Led Lights. 228 Deck Boxsupply, Instalation, Testing & Commissioning Of Abs White Plastic Deck. 229 Upvc Pipes Providing And Fixing Upvc Pressure Pipes ( 10Kg / Cm2 ) With Plain Socket Suitable For Solvent Cement Jointing Conforming To Is:4985 / 2000 & Fittings Conforming To Is 7834 / 87.Cut To Required Lengths Including All Necessary Fittings And Specials Such As Bends, Tees, Unions, Reducers, Flanges And Plugs Etc. The Pipes & Fittings Shall Be Tested To A Pressure Of 10 Kg / Sq.Cm.A ) 32 Mm Dia 230 50 Mm Dia 231 63 Mm Dia 232 75 Mm Dia 233 90 Mm Dia 234 110 Mm Dia 235 160 Mm Dia ( Rate Only ) 236 200 Mm Dia ( Rate Only ) 237 Ball Valve Providing And Fixing Pvc Lever Operated Ball Valve Of Full Flow With Setting And Gland Of Superior Quality Having Minimum Ball Working Pressure Of 10 Kg / Cm2 With Union, Flanges Where As Required.A ) 32Mm Dia ( Rate Only ) 238 40Mm Dia ( Rate Only ) 239 50Mm Dia 240 63Mm Dia 241 75Mm Dia 242 90Mm Dia ( Rate Only ) 243 Butterfly Valveproviding And Fixing Upvc Butterfly Valves. Tested To A Pressure Not Less Than10 Kg / Sq.Cm. Including Rubber Gasket, Flanges, Nuts, Bolts, Washers Complete As Required.A ) 90 Mm Dia ( Rate Only ) 244 110Mm Dia 245 160 Mm Dia ( Rate Only ) 246 200 Mm Dia ( Rate Only ) 247 Non Return Valve Providing And Fixing Pvc Ball Type Or Spring Loaded Non Return Valve With Setting And Gland Of Superior Quality Having Minimum Working Pressure Of 10 Kg / Cm2 With Union, Flanges Where As Required. 50Mm Dia ( Rate Only ) 248 63Mm Dia 249 75Mm Dia 250 Providing And Fixing Of Upvc Wafer Check Valve Non-Return Valves ( Pn 10 ) Complete With Matching Flanges, Rubber Insertion, Nuts, Bolts And Washer Etc. Of Following Sizes. A ) 75Mm Dia ( Rate Only ) 251 90 Mm Dia 252 110 Mm Dia 253 Puddles Sleeve Supply & Fixing Of Following Sizes Of Heavy Duty Pvc Puddle Flanges ( Upvc Pipe ( 10 Kg / Cm2 ) Fixed With Flanges, Length 400 To 600 Mm Length ) On The Wall Of Plantroom, Balancing Tank And The Water Body Walls & Slab ( As Required ) . To Be Laid In Between The Steel Reinforcement Before Rcc. Does Not Include Any Civil Work. A ) 32 Mm Dia ( Rate Only ) 254 50Mm Dia ( Rate Only ) 255 Supply, Laying, Testing And Commissioning Of Ss 304 Grade 200Mm Dia Pump Delivery Header With 1 Nos 200Mm Dia Flange Connection For Filter Inlet Header, 1 No. 160 Mm Dia Flange Connection For Drain Pipe & 4 No. 160Mm Dia Flange Connection For Pump Delivery. 256 Supply, Laying, Testing And Commissioning Of Following Size Pvc Insulated Sheathed Copperconductor 1100 V Grade Unarmoured Cable With Required Size Of Sleeves Complete As Required. A ) 4 X 16 Sq.Mm 257 4 X 2.5 Sq.Mm 258 3 X 4 Sq.Mm 259 2 X 6 Sq.Mm 260 2 X 4 Sq.Mm ( Rate Only ) 261 2 X 1.5 Sq.Mm 262 Providing & Fixing M.S. Structural Work Fabricated From Standard Section E.G. M.S Rounds, Angles, Channels, Plates Including Cutting To Size, Drilling, Welding Fixing And Welding To Insert Plates In Rcc Structural Members As Directed By Engineer-In-Charge Including Cutting And Making Good The Walls, Ceilings And Floors ( For Pipe Supports, Clamps Etc. ) 263 Electrical Control Panelsupply, Installation, Testing And Commissioning Of 415 V, 1 / 3 Phase And 50 Hz Motor. The Switchboard Cubical Indoor Type Made Of 16 Swg Crca Sheet Painted With Powder Coated Paint Of Siemens Grey Shade. The Cubical Is Wall Mounted With Dust & Vermin Proof Construction With Inter Connection. It Comprise With The Following:A ) One Incoming Mains Of 63 Amps. Mccb – Tp, Schneider B ) One No. 0 – 600 V Digital Voltmeter, Mecon Make 96 Sq.Mm With Voltage Selector Switch. Make. C ) Three Phase Led Type Indicating Lights For Incoming Mains. D ) One No. Ct Operated 0 – 60 / 5 A Digital Ammeter, Mecon E ) Two No. Star Delta Starter Schneider Make With On / Off Push Button And On / Off Indication Light F ) Two No. Star Delta Starter Schneider Make With On / Off Push Button And On / Off Indication Light G ) Four No. Auto / Manual Selector Switches, Salzer Make H ) One No. Mcb Dp 6 Amps. For U / V System, Schneider Make. I ) One No. Toggle Switch For U / V System, Hsd Make. J ) One No. Mcb Sp 6 Amps. For Smps Dc Power Supply For Led Light, Schneider Make. K ) One No. Toggle Switch For Led Pool Lights, Hsd Make.Total C / O To Summary 264 Pond Aerationsupply, Instalation, Testing & Commissioning Of Surface Aerating Fountain With Pump, Float, Spray / Fountain Nozzle, Conrtol, Lights And Cable, Pump Capacity 1-3 Hp The Aerator Shall Be A Floating 265 Supply, Instalation, Testing & Commissioning Of Surface Aerating Fountain With Pump, Float, Spray / Fountain Nozzle, Conrtol, Lights And Cable, Pump Capacity 5-7.5 Hp The Aerator Shall Be A Floating 266 Supply, Instalation, Testing & Commissioning Of Surface Aerating Fountain With Pump, Float, Spray / Fountain Nozzle, Conrtol, Lights And Cable, Pump Capacity 10 Hp The Aerator Shall Be A Floating 267 Supply, Instalation, Testing & Commissioning Of Surface Aerating Fountain With Pump, Float, Spray / Fountain Nozzle, Conrtol, Lights Ss Frame And Cable, Pump Capacity 10 Hp The Aerator Shall Be A Floating 268 Miscellaneous Item ( Hanging Wire Etc ) Total C / O To Summary 269 Golf Course Water Bodies / Ponds Stpwater Supply:Making Connection Of G.I. Distribution Branch With G.I. Main Of Following Sizes By Providing And Fixing Tee, Including Cutting And Threading The Pipe Etc. Complete : A ) 25 To 40 Mm Nominal Bore 270 B ) 50 To 80 Mm Nominal Bore 271 Fixing Water Meter And Stop Cock In G.I. Pipe Line Including Cutting And Threading The Pipe And Making Long Screws Etc. Complete ( Cost Of Water Meter And Stop Cock To Be Paid Separately ) . 272 Brass Fittings Providing And Fixing Gun Metal Gate Valve With C.I. Wheel Of Approved Quality ( Screwed End ) :A ) 25 Mm Nominal Bore 273 B ) 20 Mm Nominal Bore 274 C ) 32 Mm Nominal Bore. 275 D ) 40 Mm Nominal Bore 276 E ) 50 Mm Nominal Bore 277 F ) 65 Mm Nominal Bore 278 G ) 80 Mm Nominal Bore 279 Providing And Fixing Ball Valve ( Brass ) Of Approved Quality, High Or Low Pressure, With Plastic Floats Complete : A ) 15 Mm Nominal Bore 280 B ) 20 Mm Nominal Bore 281 C ) 25 Mm Nominal Bore 282 Providing And Fixing Gun Metal Non- Return Valve Of Approved Quality ( Screwed End ) :A ) 25 Mm Nominal Bore Horizontal 283 Vertical 284 B ) 32 Mm Nominal Borehorizontal 285 Vertical 286 C ) 40 Mm Nominal Bore Horizontal 287 Vertical 288 D ) 50 Mm Nominal Bore Horizontal 289 Vertical 290 E ) 65 Mm Nominal Bore Horizontal 291 Vertical 292 F ) 80 Mm Nominal Borehorizontal 293 Vertical 294 Providing And Fixing Brass Ferrule With C.I. Mouth Cover Including Boring And Tapping The Main :Providing And Fixing Brass Ferrule With C.I. Mouth Cover Including Boring And Tapping The Main :15 Mm Nominal Bore 295 Providing And Fixing Brass Ferrule With C.I. Mouth Cover Including Boring And Tapping The Main :Providing And Fixing Brass Ferrule With C.I. Mouth Cover Including Boring And Tapping The Main :15 Mm Nominal Bore 296 25 Mm Nominal Bore 297 C.I. / Ductile Iron Pipes & Specialsproviding And Laying S&S C.I. Standard Specials Such As Tees, Bends, Collars, Tapers, Caps Etc. ( Heavy Class ) : A ) Up To 300 Mm Dia 298 B ) Over 300 Mm Dia 299 Providing And Laying Flanged C.I. Standard Specials Such As Tees, Bends, Collars, Tapers, Caps Etc., Suitable For Flanged Jointing As Per Is : 1538 :A ) Up To 300 Mm Dia 300 B ) Over 300 Mm Dia 301 Providing And Laying S&S Centrifugally Cast ( Spun ) Iron Pipes ( Class La ) Conforming To Is - 1536 :A ) 100 Mm Dia Pipe 302 B ) 125 Mm Dia Pipe 303 C ) 150 Mm Dia Pipe 304 D ) 200 Mm Dia Pipe 305 E ) 250 Mm Dia Pipe 306 Providing Lead Caulked Joints To Spun Iron Or C.I. Pipes And Specials, Including Testing Of Joints But Excluding The Cost Of Pig Lead : A ) 100 Mm Diameter Pipe 307 B ) 125 Mm Diameter Pipe 308 C ) 150 Mm Diameter Pipe 309 D ) 200 Mm Diameter Pipe 310 E ) 250 Mm Diameter Pipe 311 Providing Flanged Joints To Double Flanged C.I. / D.I. Pipes And Specials, Including Testing Of Joints : A ) 100 Mm Diameter Pipe 312 B ) 125 Mm Diameter Pipe 313 C ) 150 Mm Diameter Pipe 314 D ) 200 Mm Diameter Pipe 315 E ) 250 Mm Diameter Pipe 316 C.I. Sluice Valves / Fire Hydrants & Fixturesproviding And Fixing C.I. Sluice Valves ( With Cap ) Complete With Bolts, Nuts, Rubber Insertions Etc. ( The Tail Pieces If Required Will Be Paid Separately ) :A ) 100 Mm Diameterclass I 317 Class Ii 318 B ) 150 Mm Diameter Class I 319 Class Ii 320 200 Mm Diameter Class I 321 Class Ii 322 250 Mm Diameterclass I 323 Class Ii 324 300 Mm Diameter Class I 325 Class Ii 326 Constructing Masonry Chamber 60X60x75 Cm Inside, In Brick Work In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) For Sluice Valve, With C.I. Surface Box 100Mm Top Diameter, 160 Mm Bottom Diameter And 180 Mm Deep ( Inside ) With Chained Lid And Rcc Top Slab 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ) , I / C Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40 Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) 12 Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design : With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 327 Constructing Masonry Chamber 90X90x100 Cm Inside, In Brick Work In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) For Sluice Valve, With C.I. Surface Box 100 Mm Top Diameter, 160 Mm Bottom Diameter And 180 Mm Deep ( Inside ) With Chained Lid And Rcc Top Slab 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , I / C Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40 Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 ( 1 Cement 3 Coarse Sand ) 12 Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design : With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 ( Rate Only ) 328 Constructing Masonry Chamber 120X120x100 Cm Inside, In Brick Work In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) For Sluice Valve, With C.I. Surface Box 100 Mm Top Diameter, 160 Mm Bottom Diameter And 180 Mm Deep ( Inside ) With Chained Lid And Rcc Top Slab 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , I / C Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40 Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) 12 Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design : With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 329 Constructing Masonry Chamber 60X60x75 Cm, Inside In Brick Work In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) For Fire Hydrants, With C.I. Surface Box 350X350 Mm Top And 165 Mm Deep ( Inside ) With Chained Lid And Rcc Top Slab 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , I / C Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand:10 Graded Stone Aggregate 40 Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) 12 Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design : With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 ( Rate Only ) 330 Air Valve & Water Meter ( Bulk Type ) : Providing And Fixing C.I. Double Acting Air Valve Of Approved Quality With Bolts, Nuts, Rubber Insertions Etc. Complete ( The Tail Pieces, Tapers Etc If Required Will Be Paid Separately ) :50 Mm Dia 331 80 Mm Dia 332 100 Mm Dia 333 Providing And Fixing Enclosed Type Water Meter ( Bulk Type ) Conforming To Is : 2373 And Tested By Municipal Board Complete With Bolts, Nuts, Rubber Insertions Etc. ( The Tail Pieces If Required Will Be Paid Separately ) :150 Mm Dia Nominal Bore 334 200 Mm Dia Nominal Bore 335 Providing And Fixing C.I. Dirt Box Strainer For Bulk Type Water Meter With Nuts, Bolts, Rubber Insertions Etc. Complete Conforming To Is : 2373 :80 Mm Dia 336 100 Mm Dia 337 150 Mm Dia 338 200 Mm Dia 339 Providingandlayings&Sc.I.Standardspecialssuitablefor Mechanical Jointing As Per Is : 13382 :Up To 300 Mm Dia 340 Filter Feedpump :Providingand Fixing Vertical, Inline Multistage Centrifugalpumpingset ( Complete Manufactured Skid-Mounted Arrangement With Manifold And Accessories ) Withstainlesssteelss-304Stage Casingandss-304Impellerswith Stainless Steel Shaft As Per Iec Standards And Gjl250 Cast Iron Suction & Discharge Casing, Connected To Tefc Ventilated Induction Motor Of 2 Pole, 2900 Rpm, Suitablefor 400 / 440 Volts, 3 Phase, 50 Hz A.C. Supply With Pressure Gauge And With Gunmetal Isolationcocks, Vibrationelimination Pads Etc. Complete With Base And Frame, Nuts And Boltsandnecessary Rcc Foundations As Per Requirementasper Instructionsandpumpshallhave Following Duty: A ) .No. Ofpumps: 3 ( 2 Working + 1 Standby ) B ) .Capacity :2000 Lpmc ) .Head :35 Md ) .Capacity :2000 Lpm E ) .Hp ( Motors ) : 75 Hp 341 Pressure Filter ( Domestic Water ) :Providing And Fixing Vertical Dual Media Pressure Filter ( Comprising Of Minimum 300Mm Bed Depth Of Anthracite And Support Media And Minimum Height On Straight 2500Mm ) Fabricated From High Performance M.S Plate Of Minimum 10Mm Thick For Shell & 12Mm Thickfor Dished Ends ( Quality Of Steel As Per Is:2062 Grade B, Thickness As Per Asme Section 8 ) Internally Treated With Coal-Tar Epoxy, Complete With Air Scouring, Collection System Complete With Initial Charge Of Media, M.S Facepiping, Valves, Accessories, External Painting With 2 Coats Of Red Oxide Primer And Enamel Paint, Testing And Commissioning Complete. ( Tested To 5.0 Kg / M2 ) A ) .Discharge : App.120000 Lph ( Each ) B ) .Filtration Rate : 24, 500 Lit. / M2 / H C ) .Each Suggested Dia App.:As Per Manifacture Detail 342 Water Softener:Providing And Fixing ‘Cation’ Ion Exchange Water Softener Fabricated From Minimum 10Mm Thick M.S. Plateon Min. Shell And 12Mm Thick M.S. Plate On Dished Ends ( Quality Of Steel As Per Is:2062 Grade B, Thickness As Per Asme Section 8 ) Complete With Initial Charge Of Filter Media And Ion Exchange Resins, Face Piping Accessories, Diaphragm Valves Of Approved Specifications, Hdpe Brine Tank Of Min. 500 Liters, Piping Testing And Commissioning Complete With Resins Of Approved Quality And Make And Regeneration Assembly Complete With Valves, Ejector, Brine Suction Valves And Piping. ( Bidder Must Indicate Type And Quantity Of Resin Used And Quantity Of Salt Required Per Regeneration ) . All Internal Parts Of The Softener Shall Be Rubber Lined As Per Approved Specifications.A ) .Minimum Expected Rate Of Flow:App.32, 000 Lph B ) .Total Soft Water To Be Produced Between Two Regenerations: App. 256 Cu.M C ) .Expected Raw Water Hardness : App. 450-500 Ppmd ) .Expected Treated Water Hardness: Less Than 5 Ppm ( Zero Commercial Hardness ) E ) .Max. Working Pressure: 4 Kg / Cm2 343 Cubical Panel Board - Plumbing : Supply, Installation, Testing And Commissioning Of Cubical Type Sectionalised Floor Standing Switch Board Of 31 Mva Fault Capacity At 415 V Complete With 3.5 Strip, 160 A Capacity Aluminium Bus - Bar Electrolytic Grade, Cable Alley, Switchgears Of Following Capacity & As Per Specifications.Incomer : 600 A Tp Mccb With Heavy Duty Solid Neutral Link With ( 0-100A ) Ammeter With 3 Ct And Selector Switch, ( 0 - 500 V ) Voltmeter With Selector Switch, Phase Indication Light Withprotection Fuse. - 01 Setoutgoings : I ) For 5 X 75 Hp Domestic Water Fixed Speed Hydroneumatic Pumps ( 1 Duty + 1 Stand By ) Ii ) For 2 X 5 Hp Sump Pump ( 1 Duty + 1 Stand By ) 150 A Tp Mcb With 40 A Dol Starter, Overload Relay, 96 Mm ( 0-40A ) Ammeter With Single Ct, Start / Stop Push Buttons, On / Off / Trip Indication Lights With Protection Fuse, Single Phase Preventer. - 01Set. 40A Tp Mcb With 25 A Dol Starter, Overload Relay, 96 Mm ( 0-25A ) Ammeter With Single Ct, Start / Stop Push Buttons, On / Off / Trip Indication Lights With Protection Fuse, Single Phase Preventer. - 01 Set.
Contract Date : Ref. Documents   |   Contract Value : Ref. Documents
BRR : 9502542 Tender For Electrical Work At Thdc Singrauli . - INTERNAL WIRING 2 Point wiring in PVC conduit, with modular type switch :- 3 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 4 Group C 5 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. 6 Group C 7 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 8 Power plug wiring in PVC conduit (2 x 4 Sq.Mm.) :- 9 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 10 Circuit / Sub main wiring in PVC conduit :- 11 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 12 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire. 13 2 X 6 sq. mm + 1 X 6 sq. mm earth wire. 14 2 x 10 sq.mm. + 1 x 6 sq.mm. Earth wire 15 4 x 10 sq.mm. + 2 x 6 sq.mm. Earth wire 16 S/F light plug point Modular Type Accessories :- 17 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 18 S/F power plug point modular Type Accessories :- 19 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 20 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required. 21 DISTRIBUTION BOARDS & MCBs 22 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as Required. 23 Single pole 24 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 25 Supplying and Fixing Following way, Horizontal Type Three Pole and Neutral, Sheet Steel, MCB Distribution Board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 26 6 Way (4 + 18), Double Door 27 8 Way (4 + 24), Double Door 28 Supplying and fixing following way, Single Pole and Neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 29 8 way , Double door 30 12 way , Double door 31 S/F DP MCB Isolator 32 Supplying and fixing following Rating, Double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as Required. 33 40 Amps 34 S/F 4P MCB Isolator 35 Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as Required. 36 63 Amps 37 S/F DP (RCCB) 38 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as Required. 39 40 Amps 40 TELEPHONE, TELEVISION & DATA SYSTEM (socket,wiring & conduting only) 41 S/F MODULAR BOXES, BASE & COVER PLATE :- 42 Supplying and Fixing Following Size/ Modules, GI Box Alongwith Modular Base & Cover Plate for Modular Switches in Recess etc. as Required. 43 1 or 2 Module (75 mm x 75 mm) 44 S/F MODULAR TYPE SWITCH / SOCKET :- 45 Supplying and Fixing Following Modular Switch/ Socket on The Existing Modular plate & Switch Box including connections But Excluding Modular Plate etc. as required. 46 Telephone Socket outlet. 47 TV Antenna socket outlet. 48 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 49 25 mm. 50 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, Unarmored Telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 51 2 Pair 52 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. 53 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 54 1 run of cable 55 LIGHTINGFIXTURESANDFANS 56 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 57 Installation, testing and commissioning of pre-wired, fluorescent fitting /compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as Required. 58 Installation of Exhaust fan in the existing opening, including making good the damage, Connection, Testing, Commissioning etc. as Required. 59 Upto 450 mm sweep 60 Fixing Louvers / Shutters for Exhaust Fan: 61 Extra for Fixing the Louvers/ Shutters Complete with Frame for a Exhaust Fan of all sizes. 62 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing 63 CABLE & ACCESSORIES 64 LT CABLE LAYING 65 Laying of One Number PVC Insulated And PVC Sheathed / XLPE Power Cable of 1.1 kV Grade of Following Size Direct in Ground Including Excavation, Sand Cushioning, Protective Covering and Refilling the Trench etc. as required. 66 Upto 35 sq. mm 67 Above 35 sq. mm and upto 95 sq. mm 68 Above 95 sq. mm and upto 185 sq. mm 69 Above 185 sq. mm and upto 400 sq. mm 70 LT CABLE JOINTING & END TERMINATION 71 Supplying and Making End Termination With Brass Compression Gland and Aluminium lugs for Following Size of PVC Insulated and PVC Sheathed / XLPE Aluminium Conductor Cable of 1.1 kV Grade as Required. 72 3½ X 25 sq. mm (28mm) 73 3½ X 35 sq. mm (32mm) 74 3½ X 50 sq. mm (35mm) 75 3½ X 95 sq. mm (45mm) 76 3½ X 120 sq. mm (45mm) 77 3½ X 150 sq. mm (50mm) 78 3½ X 185 sq. mm (57mm) 79 3½ X 240 sq. mm (62mm) 80 MISCELLANEOUS ITEMS 81 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 82 EARTHING 83 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required. 84 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.. (NEUTRAL EARTHING) 85 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 86 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 87 Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. 88 11KV HT Board, 250 KVA Transformer, 200 KVA DG Set, HT Cable & Accessories 89 H V CABLE LAYING 90 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 91 Above 120 sq. mm and upto 400 sq. mm 92 Supply and making Indoor cable end jointing with cast resin compund, including lugs and other jointing materials for following size of 3 core, XLPE aluminium conductor cable of 11KV grade as required. 93 3 C x 240 Sq.mm 94 Supply and making Outdoor cable end jointing with cast resin compund, including lugs and other jointing materials for following size of 3 core, XLPE aluminium conductor cable of 11KV grade as required. 95 3 C x 240 Sq.mm 96 Supply and Making Straight Through Cable Jointing With Cast Resin Compund, Including Ferrule & Other Jointing Materials for Following Size of 3 core, XLPE Aluminium conductor cable of 11KV grade as required. 97 3 C x 240 Sq.mm 98 RCC Hume pipes 99 Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. 100 250 mm dia 101 300 mm dia 102 100 mm dia 103 Manholes 104 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design. 105 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 106 Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 107 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 108 HDPE PIPES 109 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 110 200 mm dia (OD-200 mm & ID-175 mm nominal) 111 CABLE TRAYS 112 Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required. (Cable Tray Bends as per Requirement) 113 150 mm width X 50 mm depth X 1.6 mm thickness 114 300 mm width X 50 mm depth X 1.6 mm thickness 115 450 mm width X 50 mm depth X 2.0 mm thickness 116 600 mm width X 50 mm depth X 2.0 mm thickness 117 EXTERNAL LIGHTING 118 Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. 119 Above 4.5 metre and upto 6.5 metre 120 Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape , Hole Seeling to be done complete as required. 121 32 mm dia 122 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation and refilling the trench etc. as required, but excluding sand cushioning and protective covering. 123 Upto 35 sq. mm 124 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUME/ METAL pipe as required. 125 Upto 35 sq. mm 126 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 127 3 core 2.5 sq.mm (for6/4 Mtr Poles) 128 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 129 63 mm dia (OD-63 mm & ID-51 mm nominal) 130 TELEPHONE, TELEVISION & DATA SYSTEM (socket,wiring & conduting only) 131 Supplying & Fixing Modular Type Computer jack RJ 45 ISI mark 1 Module on existing Mounting plate and box Complete with all accessories as required. 132 Light Fixtures and Fans 133 Supply of 40W LED Recessed Light Fixture Aesthetically designed 2x2 LED Flat panel light which provides soft-light and glare free symmetrical illumination complete with all accessories as required. 134 Supply of Surface Mounted Energy Efficient, LED Luminaires 12W LED DOWN LIGHT (Round/Square) Sutaible for 220v Single Phase Supply complete with driver circuit including making connections etc as required. 135 Supply of Recess Mounted Energy Efficient, LED Luminaires 12W LED DOWN LIGHT (Round/Square) Sutaible for 220v Single Phase Supply complete with driver circuit including making connections etc as required. 136 Supply of Recess Mounted Energy Efficient, LED Luminaires18W LED DOWN LIGHT (Round/Square) Sutaible for 220v Single Phase Supply complete with driver circuit including making connections etc as required. 137 Supply, of Linear & Compact 10W Mirror Light with Decorative Grey Caps, Polycarbonate Body & Ribbed Opal Diffuser. 138 Supply of LED LuminairesBATTEN20W LED Tube Light of Box Type Prewired Indoor Luminairewith Energy Efficient Electronic Ballast, with End Caps Complete as Required. 139 Supply of Bulk Head Luminaire, heat resistant Glass cover suitable for 10W to 15W LED complete as Required. 140 Supply of Following sweep exhaust fan with guard suitable operation on single phase 230 V, 50Hz. AC Supply, with lowers /shutters in the existing opening. 141 300 mm Sweep 900 rpm 142 Supply & Fixing of 400mm Wall Mounted Fan with all accesseries as required complete for installation. 143 DISTRIBUTION PANELS 144 MAIN LT PANEL 145 NOTE:- MCCBs Wherever Specified shall have Rotary Handle. 146 Suppy , installation, testing, Design, manufacture, supply inspection, handling, assembling, affecting proper connections, testing and commissioningof2mm CRCA sheet steel fabricated cubical type Main L.T. Panel (Totally Type Test Assembled - TTA) floor mounting, dust & vermin proof, front operatedconstruction, enclosure class - IP 52,As per IEC 61439 after proper treatment with 9 tank process with top/bottomremovable gland plates, as required, double compression type cableglands,earth bus, hinged and lockable doorsto achieve dust and vermin proofcomplete with all inter connectionssmall wiring by min. 2.5 sq. mm. FRLS copper wires, ckt labels etc.The panel feeders shall be suitable for terminating suitable nos. 3.5 / 4 core armoured aluminium cable as required. Panel Should Be Internal Arc tested at 50ka for .3 sec as per IEC61641. 147 (Under no case temperature of main LT panel shall be more at any point of the panel. To avoid heating necessary exhaust fans shall have to be provided along with top louvers). 148 Degree of protection IP-42 149 The internal control wiring shall fuse less. All control wiring and metering protection shall be by MCBs. 150 Colour: Siemens Gray Powder Coated or as per approved shade. 151 INCOMER 1 FROM 250 KVA OUTDOOR TRANSFORMER 152 1 Nos. 400 amps four pole MCCB of fault breaking capacity 50 KA (Ics=Icu)fitted with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicator and frame earthing contact ,confiming to IS 13947-21993 as amended upto date complete with following Accessories. 153 1 set of 3 CTs of ratio 400/5A, Class 1.0 accuracy 15 VA burden for APFCR. 154 Independent manual spring closing mechanism - 1 No. 155 Microprocessor release (EMI and EMC certified) for over current, earth fault and short circuit protection - 1Set . 156 Multifunction meter with selector switch with suitable CTs and back up MCBs. 157 3Nos. Phase indicatingLED lamps with 2 Amp backup MCB, breaker ON/OFF/Trip indication light with 2A MCB , test terminal block set, MCB , circuits as per standatd practice , auxiallry contact for positive interlocking of the breakers as required. 158 Shunt trip coil 220 Volt AC. 159 INCOMER FROM DG SET (200 KVA) - 1 Nos 160 1 Nos. 400 amps four pole MCCB of fault breaking capacity 50 KA (Ics=Icu)fitted with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicator and frame earthing contact ,confiming to IS 13947-21993 as amended upto date complete with following Accessories . 161 1 set of 3 CTs of ratio 400/5A, Class 1.0 162 Independent manual spring closing mechanism - 1 No. 163 Microprocessor release (EMI and EMC certified) for over current, earth fault and short circuit protection- 1Set . 164 Multifunction meter with selector switch with suitable CTs and back up MCBs. 165 Protection releaseswith LSIG and Over voltage ,under voltage,Reverse power protection Relay & Metering & Accessories for each D G set incomers 166 3 Nos. Phase indicatingLED lamps with 2 Amp backup MCB, breaker ON/OFF/Trip indication light with 2A MCB , test terminal block set, MCB , circuits as per standatd practice , auxiallry contact for positive interlocking of the breakers as required . 167 Shunt trip coil 220 Volt AC. 168 1 nos battery charger with DC voltmeter and ammeter suitable for the DG sets (200 KVA) 169 INTERLOCKING 170 Interlocking logic electrical Interlocking betweenincomers and bus coupler and it should have auto start and auto trip facility for Automatic Operation of The Breakers Wit Manual Over Rid Facility 171 BUS COUPLER 172 One Number 400A 50KA 4 poleMCCB as Bus Coupler with ON/OFF Indication. 173 BUS BAR 174 500 A TPN Aluminium bus bar with heat Shrink Sleeve 175 OUTGOINGs 176 All the MCCBs Shall be Equiped/Provided with all accessories & Inbuid protection releas & MCCBs Shall be Thermal Magnetic upto 250A & Above Microprocessor Based with inbuiltO/L & S/C release. 177 1 Nos. 200 AMPSTP MCCB (Capacitor Panel) 178 1 No. 125A 36KA4P MCCB. (Ground Floor Panel) 179 1 No. 125A 36KA4P MCCB. (First Floor Panel) 180 1 No. 125A 36KA4P MCCB. (UPS Panel) 181 1 No. 100A 36KA 4P MCCB (Lift Panel) 182 1 No. 100A 36KA 4P MCCB (Fire Fighting) 183 1 No. 100A 36KA 4P MCCB (Plumbing) 184 1 No. 125A 36KA4P MCCB. (External Lighting) 185 2 No. 125A 36KA4P MCCB (Spare) 186 2 No. 100A 36KA4P MCCB (Spare) 187 Other items such as 188 1 set of control wiring 189 1 Set of designation plates 190 NOTE :- Adequate Quantity of Fire Suppression system with Pneumatic gas cylinder and Heat Sensitive Pneumatic tubing to be used in panel as perthe current fire norms & SURGE PROTECTION DEVICES Type 1 ( Class B), 4 Mode, spar type suitable for 10/350µs surge,3Nos. phase to earth and 1Nos. neutral to earth with impulse Current Iimp. ≥ 50KA Per mode & In ≥ 25kA per Mode. 191 Complete Panel as Above and complete 192 AUTOMATICPOWERFACTORCORRECTIONPANEL(CAPACITOR PANEL) - 90 KVAR- INNOVATION CENTER BLOCK 193 Supplying, Installation, Testing and Commissioning of cubicle type capacitior panel suitable for 415 & 3 phase 50 HZ A.C. supply System fabricated in compartmentalised design from CRCA Sheet Steel of2 mm thick for frame work and cover, 3 mm thick for gland plates i/cpowder coating in approve shade having 500 AMP capacityTPN Aluminium bus bar DMC/SMC bus bar supprot entire pannel should have common Al. earth bar for size 50 mm x 5 mm i/c Providing & fixing following switch gear mounting there on fans,grills for propor ventillation complete with gaskets & inner connection i/c connection with existing CTS in the main CT Panel complete as reqd. The panel board shall be of dust and verm proof with degree of protection IP 42) 194 a) 200 Amps TP MCCB with Microprocessor Based release and E/F proctection with time dely(Ics=100% Icu) - 1 No. 195 b) 250A, 4 strip Tinned Aluminium busbar -1 Set 196 c) Micro processor based automatic Power factor control relay i/c power factor metre in 8 steps 197 d) Multi functional meters with suitable CTS and protection MCBS 1 set. 198 e) 3 Nos. Phase indieating right (lamp) with MCBs protection. 199 OUTGOINGS- 200 1 Set - 63 Amp TP MCB 10 KA and Capacitor duly switching contactor for 20 KVAR capacity auto mannual selector switch start/stop puch button on/off indicatting lamp with protection MCB & delay timer complete i/c 20 KVAR mixed dielectric with 7% detuned filter copper reactor type capacitor bank with inter Connection 201 7 Set - 40 Amp TP MCB 10 KA and Capacitor duly switching contactor for 10 KVAR capacity auto mannual selector switch start/stop puch button on/off indicatting lamp with protection MCB & delay timer complete i/c 10 KVAR mixed dielectric with 7% detuned filter copper reactor type capacitor bank with inter Connection 202 complete panel as above and complete 203 GROUND & FIRST FLOOR PANEL (TYPICAL) 204 SITC of cubicle LT pannel suitable for 415V, 3 phase, 4 wire 50 HZ Ac supply system, fabricated in conmpartmentalized (preferbly) design from CRCA sheet of 2mm thick for frame work and covers, 3mm thick for gland, plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having suitable Amp capacity extensible type TPN aluminium alloy bus bars of high conductivity, DMC/SMC bus bar supports, , bottom base channel of MS section not less than 50mm x 50mm x 5mm thick,entire pannel shall have a common copper earth bar 25mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of AI. bus bars and control wiring with 2.5 sq.mm. FRLS PVC insulated copper conducter S/C cable, cable alleys, cable gland plates in two half. i/c providing following switch gears :- 205 INCOMER : 125 AMP 36KA FP MCCB 206 BUS BAR :160 AMP,500 Volts, 3 phase 50 HZ4P high conductivity electrolytic Aluminium bus bar of suitable length, insulated by heat shrinkable sleeves. 207 OUT GOINGS: 208 63 AMP 4P MCB Including 1 no. of Indication Lamp (DBs) - 6 209 63 AMP 4P MCB with1 no. of Indication Lamp (Spare) - 2 210 40 AMP DP MCB with1 no. of Indication Lamp (Spare) - 1 211 complete panel as above and complete 212 UPS PANEL 213 SITC of cubicle LT pannel suitable for 415V, 3 phase, 4 wire 50 HZ Ac supply system, fabricated in conmpartmentalized (preferbly) design from CRCA sheet of 2mm thick for frame work and covers, 3mm thick for gland, plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having suitable Amp capacity extensible type TPN aluminium alloy bus bars of high conductivity, DMC/SMC bus bar supports, , bottom base channel of MS section not less than 50mm x 50mm x 5mm thick,entire pannel shall have a common copper earth bar 25mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of AI. bus bars and control wiring with 2.5 sq.mm. FRLS PVC insulated copper conducter S/C cable, cable alleys, cable gland plates in two half. i/c providing following switch gears :- 214 INCOMER : 160 AMP 25KA FP MCCB (Including BY Pass Switch for 50 KVA UPS) 215 BY PASS Switch for UPS 160 AMP FP- 1 no. 216 BUS BAR :200 AMP,500 Volts, 3 phase 50 HZ4P high conductivity electrolytic Aluminium bus bar of suitable length, insulated by heat shrinkable sleeves. 217 OUT GOINGS: 218 63 AMP 4P MCB Including 1 no. of Indication Lamp (DBs) - 7 219 40 AMP DP MCB Including 1 no. of Indication Lamp (DBs) - 2 220 63 AMP 4P MCB Including 1 no. of Indication Lamp - 2 221 100 AMP 4P MCCB Including 1 no. of Indication Lamp - 1 222 63 AMP 4P MCB with1 no. of Indication Lamp (Spare) - 1 223 40 AMP DP MCB with1 no. of Indication Lamp (Spare) - 2 224 complete panel as above and complete 225 LIFT PANEL 226 Design, manufacture, supply, installation, testing and commissioning of cubicle type panel fabricated out ofCRCA sheet steel , floor mounted totally enclosed switchbaord suitable for use of 415 volts , 3 phase, 50 HZ completewith aluminium bus bar and all accessories including supply and fixing of following incoming and outgoing switchgears, Panel Should Have Double Earthing Provision which connected to the nearest earth grid. 227 INCOMER :100 AMP FP MCCB 228 BUS BAR : 125 AMP, 4P high conductivity electrolytic Aluminium bus bar of suitable length, insulated by heat shrinkable sleeves. The current density of bus bar shall be minimum 0.8 sq mm / amp. 229 The Maximum allowable temperature for the Bus bar to be restricted to 90 deg C. The temperature rise should be restricted to 45 deg C above ambient temperature. 230 OUT GOINGS: 231 1 No 63 AMP 4P MCB(Lift) 232 1 No 40 AMP DP MCB(Machine Room DB) 233 1 No 40 AMP DP MCB(Spare) 234 1 No 63 AMP 4P MCB(Spare) 235 complete panel as above and complete 236 EXTERNAL LIGHT FEEDER PILLAR 237 Design,Manufacture, Supply, Installation,Testing and CommissioningofPanelFabricated out of 16 SWG CRCA sheet steel,IP 54, wall / floor mounting type with rain canopyThe sheet steel shall undergo minimum 7 tank treatment followed by finishing powder coating of min 60 micron thickness. the board includes415 /240 V electrolitic Aluminium Bus Bar, removable gland plates, cable glands,including connection with outgoing feeders completeinall respect, Panel Should Have Double Earthing Provision Which Connected to the Nearest Earth Grid. 238 INCOMER: 239 1 no. 125A, 25KA 4P MCCB with microprocessor based releases, ON indication, 1 no. multifunction meter (showing all power parameters), with Selector Switch, Matching Cast Resin CTs. + 3 Nos 63A DP MCB For each Phase.with 3 Nos Astronomical Weekly programmabletime switch (SST- 1min) ON Phase for automaitc switching of landscape light fixtures at sun set and sun rise or twilight (auto on/ auto off and auto mode) with manual override faiclity with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site. 240 BUS BAR 241 TPN Aluminium bus bar with heat Shrink Sleeve rated for 125A. 242 OUTGOING 243 18 nos 16A DP MCB 244 2 nos 40A DP MCB 245 1 nos 40A 4P MCB (SPARE) 246 Other items such as 247 1 Set of control wiring 248 1 Set of designation plates 249 All Items complete as above 250 CABLE & ACCESSORIES 251 Supplying of Following Sizes of 1.1 KV Grade MulticoreAluminium Conductor XLPE Power Cable Insulated armoured cable conforming to IS:7098 (Part - I) or as per Relevant IS Code complete with all Amendments etcand should be NABL certified as required. 252 3.5 C X 240 Sq.mm Al. XLPE arm. 253 3.5 C X 185 Sq.mm Al. XLPE arm. 254 3.5 C X 150 Sq.mm Al. XLPE arm. 255 3.5 C X 120 Sq.mm Al. XLPE arm. 256 3.5 C X 95 Sq.mm Al. XLPE arm. 257 3.5 C X 50 Sq.mm Al. XLPE arm. 258 3.5 C X 35 Sq.mm Al. XLPE arm. 259 3.5 C X 25 Sq.mm Al. XLPE arm. 260 MISCELLANEOUS ITEMS 261 SITC of CO2 Fire Extinguishers 4.5 kg capacity complete in all respect ISI : 15683 marked. As per Safety plus extinguisher fire carbondioxide 4.5kg, duly charged, portable and complete as per defence specification (safetyplus SPEC 4.5) 262 UPS 263 UNINTERRUPTED POWER SUPPLY (UPS) - 50 KVA 264 Supply of 50 Kva Online UPS, IGBT UPS(Transformer-less Design). 265 Supply of SMF Batteries (12Volt VRLA, 120 Ah, 28 Numbersto provide 30 Min Backup in total for 50 kva UPS at 0.8PF and ECV=1.7V. 266 Fully rated Inbuilt static switch at the inverter output and 100% rated Inbuilt static switch at the static bypass line integrated in UPS module. 267 Supply of Local Accessories (like Cabling Between UPS and the Battery onsidering Cable Routing ,Battery Interlinks , Battery Rack etc). 268 Backfeed protection at Mains & Bypass (Inbuilt / External). 269 Installation and Commissioning of 50 kVA UPS, Battery and Accessories. 270 Supply , installation , testing and commissioning 160A FP MCCB of25KA breaking Capacity in metal sheet enclosure with ON/OFF, TYB Indication lamps for Incoming of UPSComplete in All Respect as Required. 271 SUB STATION - 11KV HT BOARD, 250 KVA TRANSFORMER, 200 KVA DG SET, HT CABLE & ACCESSORIES 272 11KV SINGLE VCB PANEL BOARD 273 11KV SINGLE PANEL HT VCB (Indoor Type) - ONE INCOMERS CUM OUTGOING 274 Design, Manufacture and Supply of 1 Panel, 11 kV HT VCB Switch Board with Following Accessories : 275 Incoming Cum Outgoing 276 Indoor Type - 630A, 11kV, 350MVA for 3 Sec., TP, Horizontally isolated, horizontally drawout type, motorised spring charged, closing mechanism, motor voltage 230V AC, shunt tripping & Closing coil Voltage 24V DC, Electrically Operated, Trip Free, Dust & Vermin Proof, Vacuum Circuit Breaker (VCB) With Mechanical & Electrical OFF/ON Indicators & Provided with Following -1 No. 277 CT chamber with double wound single phase, cast resin CT, 15VA burden with core-1 for metering (CL-1) and core-2 for protection (CL-5P10) and of 60/5/5A ratio - 3Nos. 278 IDMT relay with 3 elements for over current (50-200%) and 1 element for earth fault protection(10-40%). - 1 Set 279 Anti Pumping Relay - 1 Set. 280 Master Trip Relay - 1 Set. 281 Trip circuit supervision relay - 1 Set. 282 Potential Transformers, 3 Phase, 3 Limb,Drawout Type, Resin Cast 11000/(Root 3)/110/(Root 3) Ratio Class 1 Accuracy, 100 VA Burden, with HV fuse on primary side and MCB/ MPCB on secondary side. - 1 Set 283 6 Windows Annunciator with Hooter - 1 Set 284 1 Window for over current trip - 1 Set 285 1 Window for earth fault trip - 1 Set 286 1 Window for master trip relay - 1 Set 287 1 Window for Emergency Stop Push Button - 1 Set 288 2 Windows Spare - 1 Set 289 Digital Ammeter with inbuilt selector switch - 1 Set 290 Digital Voltmeter with inbuilt selector switch - 1 Set 291 A set of breaker ON/OFF/Trip/DC control supply healthy/Trip circuit healthy/ Spring Charged VCB in test / VCB in service & R,Y,B phase indication lamps. - 1 Set 292 Emergency stop push button -1 Set 293 Limit switches with 6 NO/ 6 NC breaker auxiliary contacts - 1 Set 294 Control:- T-N-C (Trip, Neutral, Close) breaker control switch with indication arrangement. - 1 Set 295 All control wiring with protection & test terminal block as required. - 1 Set 296 Space heater with thermostat for moisture absorption. - 1 Set 297 Suitable for connection to 3C x 240 sq.mm. Cross linked polythelene(XLPE) 11kV cables or as called for. - 1 Set 298 Cable box for 3C x 240 sq.mm 11kV XLPE Al. conductor cable. - 1 Set 299 HT Danger Plate - 2 Set 300 Incoming as described above. 1 Sets 301 Powerpack as Required to Be Included (220V/24V DC), 7AH Battery for Each Breaker Module. 302 SINGLE PANEL 11KV HT VCB PANEL AS DESCRIBED ABOVE 303 11KV TRANSFORMER(11 KV /0.433 KV) (250 KVA) 304 11KV TRANSFORMER(11 KV /433 V) (250 KVA) 305 Supply Installtion, Testing and commissioning of outdoorOil cooled Outdoor Type Transformer11 KV/433 Volt Rating 3 phase, Double Wound with copper Winding.(as per IS : 1180 (part 1) : 2014Level 2 (AMENDMENT 4)/ Equivalent IEC Standard , OLTCin Steps (+10% to -10% @ 1.25%), Insulation Class : Class A , Temperature Rise : 40 Deg.c in Oil , 45 deg.c by Resistance, 50 deg.c by Ambient , Dyn 11 Vector Group and other Standard Accessories as Required Including Followings : 306 PLEASE NOTE THE TRASNFOREMR SHALL BE IN COMPLINACE WITH NEW REGUALTION IS 1180 or Equivalent IEC Standard FOR LOSSES AND EFFICIENCY and ammended upto date 307 Civil work shall be paid extra as per actual. 308 Cable Termination box with disconnecting facility for 11 KV 3C-240 sq mm XLPE cable at 11 KV side 309 ON Load Tap Changer on HV side+10% to -10% @ 1.25%. 310 Standard Fittings , Accessories /Spares :- 311 Rating and Terminal Marking Plate - 1 312 Earthing Terminals - 2 313 Lifting Lugs - 2 314 Drain Valve with Blanking Plate - 1 315 Filter Valve with Blanking Plate - 1 316 Conservator - 1 317 Conservator Oil Filling Hole With Cap - 1 318 Oil Level Indicator with Min. Marking - 1 319 Dehydrating Breather - 1 320 Conservator Drain Plug - 1 321 Air Release Device - 1 322 Pressure Relief Valve - 1 323 Thermometer Pocket - 1 324 Rollers uni directional - 4 325 Radiators Detachable - 4 326 HV Cable Box- 1 327 LT Cable Box - 1 328 Seperate Neutral Terminal - 1 329 ON Load Tap Changer - 1 330 OTI with alarm and trip contacts 331 Buchholz relay with alarm & trip contact 332 Current Transformer 333 Radiator Valve 334 Marshalling Box 335 WTI with alarm & trip contact 336 WTI Pocket 337 Drain Valve with Blanking Plate (OLTC) 338 Filter Valve with Blanking Plate (OLTC) 339 OLTC Surge Relay 340 RTCC Indoor 341 AVR 342 250 KVA (11/433V) AS DESCRIBE ABOVE 343 DIESEL GENERATOR SET - 200 KVA DG SET :- 344 200 KVA DG SET 345 Supply, intastallation, Testing & Commissioning of200 KVA Capacity Radiator cooled DG Set with Suitable StandardAMF Panel & suitable capacity engine directly coupled withalternator for 415 volt, 3 phase, 50 Hz, 4 wire, Generation system complete with accessories, Fuel Oil Tank & Control Panel etc as Required and sound proof acquastic enclosurefor the DG SET (75 db @ 1m) , including supply,fixing of antivibration pads suitable for 200 KVA DG Set as per standards of Engine manufacture, provision of conrol cablefrom engine to control panelto engine. Provision of pipe fuel pipe line of suitable size from fuel tank to engine and over flow pipe engineto fuel tank complete gatevalve and fitting leader maker etc. Supply , Intallation of starting batteries of suitableAH as recommended by manufacterer Heavy duty complete as required at site complete with stand and battery charger residentials silencer sutaible for diesel engine exhaust pipe line complete complete flange, bend, flexible pipe all as required and as directed by Engineer Incharge. 346 Diesel Engine (CPCB-4 NORMS COMPLANT) 4 Stroke, Radiator Cooled, Diesel Engine Model Developing Output Prime 160 KW Having Following Arrangement :- 347 Flywheel With Starter Ring for Generating Set 348 Air Filter , Lube Oil Cooler Assembly with Accessories. 349 Exhaust Air Manifold 350 Exhaust Bellow 351 Fuel Fiter 352 Diesel engine pre heating arrangement 353 Lube Oil Filter 354 Exhaust Gas Turbo Charger with After Coller 355 Day Tank For fuel with Markings 356 ECP Panel mounted on a Separate Frame. 357 Radiator with Pusher Type Fan, With Fan Guard, Coolant Pump. 358 12V Electrical Starting System with Starter Motor and Battery Charging Alternator. 359 Engine Mounting Supports 360 ALTERNATOR Rated at 200 KVA, 415 Volts, 3 Phase, 4 Wire, 0.8 P.F (lag), 50HZ, 1500 RPM, IN Accordance with IS 4722 /IEC 60034 as per following Specification. 361 Rating: Suitable for an over-load of 10% for 1 hour in every 12 hours operation. 362 Voltage Regulation: Provided with Fast Response Thyristor Type Electronic automatic voltage regulator, which holds output voltage within desired limits. (+/- 1%). 363 Excitation: Self Excited - Self Regulated. 364 Alternator Loading: Suitable for Taking Rated load Immediately After Machine Reaches Rated Voltage and Speed. 365 Vibration: Suitable for Direct Coupling with Engine and Mounted on Common M.S. Channel Base Frame. 366 Enclosure: Screen protected drip proof enclosure with IP – 23 degree of protection. 367 Cooling: Air Cooled type with radial fan mounted on Rotor. 368 Winding and Insulation: Insulation class H as defined in IEC – 60034-1 369 ACCESSORIES :- 370 MS Base Frame Suitable for Mounting of the Offered Engine and Alternator. 371 Day Fuel Tank of Standard Capacity as per Rating Complete Fuel Gauge, Inlet/Outlet Connections, Drains Plug, Etc. 372 Residential Silencer (1.5 Meter with 750 mm diaApprox) Including Insulation of Silencer. 373 2 Nos 12 Volts DC Battery of Suitable Capacity with Leads. 374 1 Set of AVM Pads Fitted in Base Frame. 375 TOTAL FOR 200 KVA DG SET 376 Supply of H.T. Cable 377 Supply & Testing of following 11 KV (E) grade multicore Aluminium conductor XLPE insulated cable, insulation screening withextruded semi conducting compound in combination with copper tape armoured cores laid up, inner sheath of PVC tape, galvanised steel flat strip armoured and overall PVC sheathed cable conforming to IS: 7098 (Part - II) and complete with all latest amendments etc. complete as required. 378 3 C x 240 Sq. mm11 KV (E) 379 Supply , Installation, Testing & Commissioning of Integrated Post Top Lantern With 40W LED Lampincluding Pole &connection with 3 x 2.5 sq.mm single core PVC insulated copper conductor cable from junction box to fixture as required. 380 Supply , Installation, Testing & Commissioning of 50 W LED withcomplete with pot optic reflector connection with 3x2.5sq.mm single core PVC insulated copper conductor cable from junction box to fixture as required. 381 Supply, Installation, Testing and Commissioning of 200x160x98 (KVPC) Polycarbonate thermoplastics enclosure - junction box with I.P - 65 Protection with Terminals &cable hinged cover of approved design complete having gasket of internally embedded & made of polyeutherene & should be weather proof, rust proof, dust proof, water proof - box shall be tested as per IEC - 60670-2/60670-22. the box shall have self threaded holes & provision for mounting din rail. with 2 Nos cable gland including supplying & fixing crimping 2 nos lugs & 1 nos 32A connector 6 way for looping the incoming & outgoing cables and also connection of the street light one 6A SP MCB Including Connection of 2x6 sqmm Cable etc as Required. 382 Supplying of 6 mtr long hot dip Galvanized octagonal Pole with top of the pole 70 mm dia (A/F) and bottom of the pole 130 mm dia (A/F) made out of 3mm sheet with MS base plate of size 200mm (NS) x 200mm (NS) x 16mm (NS) on precast RCC foundation complete with suitable size openinginside the pole with flush weather proof door with locking facility preferably with LN key having proper arrangement with Accommodating of 1 Nos. 6 Amp.,10 KA MCB & neutral link4 way connector suitable for 25 Sqmm cable complete with electrically safe including inside cable termination with thimbles i/c wiring from pole box to fitting with 3x1.5 sq.mm. FRLS PVC insulated copper conductor wire, earth connection, din channel, earth stud and other accessories pertaining to this pole (But without street light fitting) etc as reqd.including providing & laying in position suitable RCC foundation as required for 6 mtr. octagonal hot dip Galvanized Pole as per Manufacturers drawing with 1:1.5:3 concrete (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size ) including excavation of all kind of earth such as all type of soil/soft rock or hard rock etc. as per existing site condition i/c providing, cutting, bending and placing reinforcement & IncludingJ typefoundation bolts , anchor plate and templates in position as per manufacturer Standard and Providing PVC Pipe for Cable Entry and Exits Including Disposal of Surplus Malba / Softrock / Hardrock Stone etc.as Required. 383 Supplying of Following sizes 1100 volt grade XLPE insulated PVC sheathed aluminium conductor armoured cables as per specification in existing laid in ground including cost of digging upto required depth, 150 mm sand all around the cable, brick protection and back filling, clamped to wall with suitable clamps including saddles fixing bolts, Connection Testing and commissioning as Required. 384 2x6 sqmm 385 Supplying of Following sizes 1100 volt grade XLPE insulated PVC sheathed aluminium conductor armoured cables as per specification in existing trenches/pipes, cable trays, ducts, clamped to wall with suitable clamps including, saddles fixing bolts, connecting testing and commissioning as Required. 386 2x6 sqmm 387 Supply, Installation, Testing and Commissioning of 120w Flood Light, Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP65 flood light, suitable for highlighting architectural facade and general purpose lighting. 388 SOLAR POWER SYSTEM 389 Supplying, installation, testing and commissioning of Grid interactive roof top solar photo voltaic power generation system including space frame 390 (SCHEDULED ITEMS - AS PER DSR (E&M) 2022 391 (A) Supplying , installation , testing and commissioning of electric driven terrace pump suitable for automatic opeartion and consisiting of the following, complete in all respects as required:( Terrace pump) 392 (B) Horizontal type, multistage, centifugal, split casing pump of cast iron body & bronze impeller with stainless shaft, mechanical conforming to IS:1520 393 © Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 hz, AC supply with IP55 clas of protection for enclosure, horizontal foot mounted type with class-F insulation, conforming to IS-325. 394 (d)M.S fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. 395 (E)Suitbalecement concrete foundation duly plastered and with anti vibration pads. 396 Discharge : 450 liter per minute 397 Head : 35 meter 398 Providing, laying, testing & commissioningof C class heavy duty MS pipe conforming to IS 3589/IS 1239 including welding, fittings like elbows, tees, flangers, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required: 399 100 mm dia 400 Providing, laying, testing & commissioning of B class medium duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc, and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required: 401 100mm dia 402 Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type-A) with blank Gunmetal/Stainless Steel cap and chain as required: 403 Single headed Stainless steel. 404 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required. 405 100 MM NB 406 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required 407 100 NB 408 Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange 409 100 mm dia. 410 Supplyinig and fixing 63 mm dia , 15 mm long RRL hose pipe with 63 mm dia male and female couplings duly bound with GIwire , rivets etc.confirming to IS 636 (type-A) as required: 411 Supply, fixing first aid Hose Reel with MS costruction spray painted in post office red , conforming to IS 884 complete with the following as required 20 mm nominal internals diawater hoseThermo plastic (Textile reinforced) type -2as per IS 12585) 20 mm nominal internal dia gun metal globe valve & nozzle Drum and brackets for fixing the equipments on wall .connections from riser with 25 mm dia stop gun metalvalve & M.S . Pipe and socket.40 M 412 Supplying and fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle confirming to IS 903 Suitable for instantaneous connection to interconnect hose pipe coupling as required:Stainless steel (Grade 304) 413 Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 414 2 way-100 mm dia M.S. Pipe 415 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required. 416 TOTAL- A(SCHEDULED ITEMS - AS PER DSR E&M 2022) 417 (NON SCHEDULED ITEMS - AS PER MARKET RATES) 418 Supply & erection of ISI marked portable fire extinguishers, confirming to IS:15683, wall mounted type, wall brackets complete in all respect as per standard item with all accessories, delivery hose & nozzle whereever required, including fixing on walls as per the directions ofEngineer-in-charge. 419 Water CO2type. 9 Lt. capacity 420 D.C.P.Type 6 kg. capacity 421 ABC dry powder Type 6 kg. capacity 422 CO2 gas type. 6.5 kg. cap. -Trolley mounted 423 Providing & fixing neoprene rubber double flangedrubber expansion joint(anti vibration bellow) of standard length as per manufacturers specifications. suitable for hydrostatic test pressure of 21 kg/sqcm including all necessary fittings i.e. rubber gasket, nuts, bolts, washers etc complete as required. 424 100 mm dia. 425 150 mm dia. 426 Providing & fixing standard carbon steel fireman axe with rubber insulated handle tested to 20000 Volts. 427 Supply, fixing, testing & commissioning of 25 mm dia inspecting and testing assembly with gun metal valve, sight glass, by pass valve and connection to the drain line as required to complete the system. 428 Providing and fixing of cast iron body 100 mm dia Draw out connection in Under ground water storage tankwith heavy class MS suction pipe of required length,foot valve, suction coupling in conformity with local regulations complete in all respects. 429 Providing and fixing weather proof standard fire hose cabinet (750 mm x 600 mm x 250 mm)outdoor typemade of not less than 16 SWG MS sheethaving glassed hinged door (5 mm thick glass) including necessary locking arrangement with handle for housing two nos.15 meter long fire hose pipes, branch pipeas required as per drawings, including brackets for mounting accessories, painting (one coat primer and two coat of fire red colour). The cabinet shall be mounted onself standing mounted type MS Angle iron frame as required. The words FIRE HOSE to be painted on the box. 430 Providing and fixing standard fire hose cabinet door with frame (900 mm x 2000 mm ) or (suitable to fit in the duct made of not less than 16 SWG MS sheethavingglass hinged door (5 mm thick glass) including necessary locking arrangement with handle as required as per drawings, including brackets for mounting accessories, painting (one coat primer and two coats of fire red colour). The door shall be fixed in the masonry wall or as required. The words FIRE HOSE to be painted on the box. 431 Supply, installation and testing of cylindrical type flanged pressurevessel tank, 450 mm dia, 2 m long and of 10 mm thick M.S., common for a set of fire pumpsincluding flanged connection, suitable supporting legswith MS plate of size 75x75x5 mm at the bottom and grouted in CC foundation. The air vessel tank shall be provided with air release valve, stop cock, safety valve, pressure gauge, 50 mm dia drain valve, suitable length of connecting pipe and valve from delivery header to vessel tank, suitable pressure switches to operate all pumps (1 nos each), tested to min 25 KG/cm2complete including painting with synthetic enamel paint of approved shade with all accessories as per direction of the Engineer-in-charge. (For Pump House) 432 Providing & fixing 100 mm dia dial pressure gauge including making connections with MS pipecomplete in all respects. 433 PART-A EQUIPMENT 434 OUTDOOR UNITS (HEAT PUMP TYPE) 435 Supplying,installing,testingandcommissioningofaircooled variable refrigerant volume / Flow modular typeairconditioning system with R410a refrigerant. The PCB Chamber of outdoor unit should be refrigerant cooled suitable for 415±10% 3 Phase, 50 cycles. The unit shall consist of indoor and out door units withindividual controllerasperdetailgiveninspecifications andhaving followingitems:(Theseitemsareto be giveninIndian rupeeswithcustomduites,inlandfrt,clearanceetconSitebasis) 436 Modular type outdoor units equippedwith highlyefficient 100% inverter type hermitically sealed scroll compressors, minimum two comprossors for and above 14 HP modules, with special precoated heat exchanger, low noise condenser fan housed in compact housing duly powder coated and manufacturer of compressor and outdoor unit should be same. The Unit should have automatic refrigerant charge function. The static pressure of the outdoor unit shall be more then78Patoavoidhotairrecirculation.The unitshallbeabletooperateuptoto45°Cin coolingmode.The unit shall also have feature to automatically modulate the evaporative temperature between 6 deg C to 11 deg C with respecttoloadforbettercomfortandenergy efficiency etc complete as reqd. The units should have free phase technology for countinued operation. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping .The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5 of following capacitites: 437 Cost of R 410 A Gas should be inclusive 438 The outdoor unit should include all loading, unloading, transportation, power cabling/wiring from near the indoor and outdoor units respectively. 439 The outdoor unit should include all loading, unloading, transportation, power cabling/wiring,( Y/T joints which is required for ODU Zone requirement Modules) from near the indoor and outdoor units respectively. Outdoor Units-Heat Pump , Fully Gas Charged and Aluminum fins within the ODU (condensing) unit shall be coated with polysiloxane based coating. 440 The Vendor should considere the deration on ODU election as per Singroli MP Ambient conditions 441 18 HP Outdoor unit VRV/VRF Zone-01 442 16 HP Outdoor unit VRV/VRF Zone-02 443 22 HP Outdoor unit VRV/VRF Zone-03 444 26 HP Outdoor unit VRV/VRF Zone-02 445 INDOOR UNITS 446 Supply, installation, testing and commissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ±10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree CDB and 19 Degree C WB temperature. 447 Ceiling Mounted Cassette Unit 448 300-318 CFM / 0.63-0.80 TR 449 310-335 CFM / 1.0 TR 450 600-670 CFM / 1.2-1.3 TR 451 812-830 CFM / 1.6-2.0 TR 452 850-865 CFM / 2.5-2.8 TR 453 1130-1165 CFM / 3.1-3.2 TR 454 Ceiling Mounted HSP Ductable Unit 455 1130 -1150 CFM / 3.0-3.40 TR 456 1200-1377 CFM / 3.95-4.0 TR 457 1600-2050 CFM / 4.5-5.5 TR 458 2047-2295 CFM / 6.36-7.1 TR 459 REMOTE CONTROLLERS 460 Supply, installation, tesing and commissioning of Imported Remote controllers (Corded) for operation of ductable indoor units and AHUs. 461 Touch screen controller for indoor units controller - VRV 462 Supply, installation, testing and commissioning of touch screen controller (Which is controlled 45 nos. indoor units in terms of ON/Off Status, temp. Status, Fan Speed, ODU On/Off Status etc.) with all accessories and controls. 463 REFNUTS /T/ Y-JOINTS 464 Supply, installation, tesing and commissioning of Imported fittings Y-joints insulated, distributer and headers for all Indoor units at both the ends floors layout as per layout drawings.All interconnecting joints, Y Joints withpolysiloxane based coating 465 REFRIGERANT PIPING 466 Supply, installation, testing and commissioning of Interconnectingrefrigerantpipe work with (13/ 19mm thick) cross linked closed cell Oxide Acetate Foam tubular insulation between each set ofindoor & outdoor units asper specifications, allpiping inside the room shall be properly supported with hangersandv All interconnecting Copper piping, joints, U bends withoxycoat dual barrier coating shall run incable tray. (Note: Ref. Piping Length may be review as per site routing) 467 06.35 mm with 13 mm thick cross linked closed cell Oxide Acetate Foam insulation 468 09.52 mm with 13 mm thick cross linked closed cell Oxide Acetate Foam insulation 469 12.70 mm with 13 mm thick cross linked closed cell Oxide Acetate Foam insulation 470 15.88 mm with 13 mm thick cross linked closed cell Oxide Acetate Foam insulation 471 19.05 mm with 13 mm thick cross linked closed cell Oxide Acetate Foam insulation 472 22.22 mm with 19 mm thick cross linked closed cell Oxide Acetate Foam insulation 473 28.58 mm with 19 mm thick cross linked closed cell Oxide Acetate Foam insulation 474 34.92 mm with 19 mm thick cross linked closed cell Oxide Acetate Foam insulation 475 41.30 mm with 19 mm thick cross linked closed cell Oxide Acetate Foam insulation 476 TRANSMISSION & CONTROL WIRING 477 Supply, installation, testing, termination and commissioning of control cum transimission wiring (should be shielded cable in PVC Pipe) of 2C x 1.5 Sqmm Cu between indoor unit and out door unit and indoor units and its remote controller. 478 2C x 1.5 Sqmm Cu Cable or as per Manufacturer OEM 479 Perforated GITray with hangers & supports for copper piping (250 mm wide) 480 Refrigerant-410a 481 Supply , charging & Leackage testing of refrigerant -410a in additionalcopper piping circuit. 482 CONDENSATE DRAIN PIPE 483 Supplying, fixing,testing and commissioning offollowing PVC pipes for condensate drain duly insulated with Fire rated Class O kinny foam /Nitrile Rubber & vapour barrier duly secured with adhesive tape as per specification ,cut to required length and installed with all joints , including the necessary fittings. (For all the AHU/FCU units upto the main header in the shaft dor vertical risers) 484 65mm dia 485 50mm dia 486 40mm dia 487 30mm dia 488 25 mm dia 489 TOTAL CARRIED OVER TO SUMMARY ( PART-A EQUIPMENTS) 490 PART-B VENTILATION 491 Propeller fan 492 Supply,installation,testing and commissioning of Certified Propeller fan of the following capacity of approved make and specification. Fan shall be supplied with aluminum gravity louver & bird screen and Speed Regulator. 493 200 mmdia propeller fan,with single phase motor 494 300 mmdia propeller fan,with single phase motor 495 450 mmdia propeller fan ,with single phase motor 496 Inline fan 497 Supply, installation, testing and commissioning ofCertified Circular/Rectangular swing type Inline fan with fiire retardent Canvas connection Speed Regulatorof the following capacity of approved make and specification. 498 100-300 CFM,5-7 mm SP WG with Single phase motor 499 350-400 CFM,10-12 mm SP WG with Single phase motor 500 600-800 CFM,10-12 mm SP WG with Single phase motor 501 Tube Axial Flow fans 502 SITC of Long case Tube axial flow fans, as per specifications and approved makes suitable for three phase operation respectively Normal/Smoke case. 503 SITC of AMCA Certified (For Air and Sound Performance) tube axial flow fan of different capacity as mentioned below in standard M.S.contruction. Entire fan model & AMCA Seal shall apear in techncial submittal of fan. All the fans are synthetic enamelled panited/hot dip galvanized with minimum 220 GSM Zinc Coating and complete with bird screen at inlet. The electric motor coupler shall be squirrel cage induction motor (IE-2 type) confirming to IS - 325-IP - 55 with class `F insulation.Fan efficiency should not be less than 70 %, noise level should not be more than 85 db @ 3 m distance when measured in hemisperical reverberant room conditions. Fans should be as per specification and drawings. (As per Vent. Fan Schedule ) (Makeup Air & Pressurization Fans with St. Press. of 40 mmWG/Make Up Air Fan at 30mm WG) 504 6000 CFM (For Stairwell/Liftwell Pressurization) 505 6500 CFM (For Smoke Extract,with H Class insulation) 506 AIR SIDE WORKS 507 Site Fabricated Duct - GI duct 508 Supply,Installation,balancing and commissioning of fabricated at site GSS sheet metal ducts (rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter,vanes, hangers, Gripple supportsetc.) in accordance with the approved shop drawings and specifications , and shall also confirm to the BIS specifications.The duct shall be fabricated at site for to suit pieces. 509 0.63mm (24 gauge) GSS 510 0.8 mm (22 gauge)GSS 511 Factory Fabricated Duct - GI duct 512 Supply,Installation,balancing and commissioning of factory fabricated GSS sheet metal ducts (rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter,vanes, hangers, Gripple supportsetc.) in accordance with the approved shop drawings and specifications , and shall also confirm to the BIS specifications.The duct shall be fabricated at site for to suit pieces. 513 0.63mm (24 gauge) GSS 514 0.8 mm (22 gauge)GSS 515 Supply, Fabrication, Installation and testing of Insulated Al. Flexible ducts in accordance with the approved shop floor drawings and specifications and shall also confirm to the BIS specifications. 516 200 mm Dia. 517 150 mm Dia. 518 Grilles/Diffusers 519 Supplying and fixing of Extruded aluminium supply and return air grilles/diffusers/louvres with dampers, supply air plenum etc. duly powder coated as per specifications and drawings. 520 Aluminium supply air grilles with damper. 521 Aluminium return air grilles without damper. 522 Aluminium supply air square diffuser with damper 523 Aluminium return/exhaust air square diffuser without damper. 524 Aluminium return/exhaust airValve circular/squirell diffuser without damper. 525 Fresh Air/Exhaust Air Louvers 526 Supplying and fixing ofextruded aluminium louvres with frame bird screeen , mounting arrangement etc. as per specifications and drawings. 527 Fresh Air/Exhaust Louvers 528 Supply,Installation,Testing and commissioning of doble layer canvas connection with 1/2 hr. fire ratingasper specification. 529 MECHANICAL INSULATION 530 DUCT LINE ACOUSTIC TREATMENT 531 Supply and installation of cross linked open cell Oxide Acetate( AccoIsolate) Foam Acoustic insulation on ducts having density of 30 to 60Kg/ M³ ,having K value 0.029 W/m ° K at 0°C Deg temp and temp range of-70°C to +100°C and fire rating Class O as per BS 476 Part 6 fromCBRI,Roorkee and CFC/HCFC free as per US EPA 5021 A(2014 ). • Smoke & Toxicity index of material shall be passed as per IMO MSC 307 ( 88 ) 2010 Anexx 1 Pt 2 andas per the approved specifications. 532 15mm thick Oxice Acetate Acco IsolateAcoustic open cell insulation on one side for Duct acoustic insulation 533 DUCT LINE THERMAL INSULATION 534 Supply and installation of cross linked closed cell Oxide Acetate( Thermo Isolate) Foam Thermal insulation on ducts having density 0f 30 ±3Kg/ M³ ,having K value 0.029 W/m ° K at 0°C Deg temp and temp range of-70°C to +100°C and fire rating Class O as per BS 476 Part 6 fromCBRI,Roorkee and CFC/HCFC free as per US EPA 5021 A(2014 ). • Smoke & Toxicity index of material shall be passed as per IMO MSC 307 ( 88 ) 2010 Anexx 1 Pt 2 andas per the approved specifications. 535 25 mm thick insulation oxide acetatefoam with 2 coat layer of 7 mile cloth with starbond or eql. adhesive on Exposed supply air duct 536 13 mm thick insulation oxide acetatefoam laminated with aluminium foil supply air duct 537 9mm thick insulation oxide acetatefoam laminated with aluminium foil supply air duct 538 EXPOSED ROOF INSULATION 539 Supply and installation of cross linked closed cell Oxide Acetate( Thermo Isolate) Foam Thermal insulation on ducts having density 0f 30 ±3Kg/ M³ ,having K value 0.029 W/m ° K at 0°C Deg temp and temp range of-70°C to +100°C and fire rating Class O as per BS 476 Part 6 fromCBRI,Roorkee and CFC/HCFC free as per US EPA 5021 A(2014 ). • Smoke & Toxicity index of material shall be passed as per IMO MSC 307 ( 88 ) 2010 Anexx 1 Pt 2 andas per the approved specifications. 540 19mmthick oxide acetate insulation for underceck plain 541 TOTAL CARRIED TOSUMMARY(Mechanical Insulation works) 542 ASSOCIATED ELECTRICAL WORKS 543 Therates for the distribution boards from the Breakers andinstrumentsshall also include the following : 544 Wiring forlight / Fan points with 1.5 sq. mm PVC insulatedcopper conductor1100 Volt grade strandedflexible FRLS wiresofapproved makein1.6mmthick25mmdiaMS conduitincluding costof providing & fixing saddles, hangers, supports, cutting chases and filling chases for recessed conduiting, and including the cost of providing and fixing a6 amp240Volt ModularPlatetypeswitchesof approved quality,colour, makeanddesign with mouldedcover platein zinc chromate passivated MS box and including the cost of running 1.5 sq. mm PVC insulated copper earth wire for loop earthing etc. complete 545 TPN ACB’s / MCCB’s shall mean 3 pole ACB’s / MCCB’s with adequatesize of neutral link. 546 All MCB’s shall be of minimum 10 KA breaking capacity and MCCB s shall be not lessthan 25KA 547 The breaking capacity of MCCB’s are mentioned panel wise. All MCCB’s shall be with thermalmagnetic microprocessorreleasesas per BOQand following : 548 i.MCCB rating upto 250 Amps with thermal magnetic releases. 549 ii. MCCB above 250 Amps with microprocessor releases. 550 All MCB’s used for protection ofresistiveand lightlyinductive loadshallbetype “B”characteristic and inductive(motor)loadshall be of type “C” characteristic. 551 Degree of protection for following type of distribution panel enclosureshall be as per IS:13947-1993. 552 i.IP 42 for indoor panels. 553 ii. IP 55 for ODU panel. 554 AllMCCB’sshall beprovidedwithoperatingmechanismfordoorinterlock. 555 All hinged door shall be earthedthrough2.5 sq mm tinnedbraidedcopper wire. 556 Providing cableclamps/ supportswithin distributionboardscablealley. 557 Current density of aluminium shall be 1sq mm for 1.0 Amps for ratedcurrent of bus bars. 558 Model, current capacity location and frame size of switchgear shall be writteninside of thepanel doors with paint / permanent marker asapproved shop drawings / site requirment. 559 All meter shall be digital type and all starter shall be as per Type-2 Coordination chart 560 Current Transfomer shall be resin cast. 561 All Panel Shall be BMS Compitable 562 AHU/Fan Panel 563 Design, fabrication, assembling, wiring, supply, installation, testing and commissioning of following LT panels fabricated out of 14 guage CRCA sheet steel in cubical formationwith reinforecment of suitable size angle iron and channel T iron flats. All steel material used in the construction of panels shall be powder coated. A solid busbar shall be provided at the bottom of the panel with two connecting eyes for termination. The boards shall be suitable for 415 volts, 50 Hz, 3 phase , 4 wire supply system. All the hardware used in the fabrication of the panel shall be galvanized with zinc passivation. The panel shall be compartmentalized to accommodate one feeder in each compartment. A vertcal cable alley of suitable width shall be provided to serve on or two vertical feeder sections. Also the opening between the busbar chamber and the feeder section shall be shrouded with bakelite / hylam sheet with min.3 mm thickness. 564 The panel drawing shall be approved before taking up the fabrication and compitable BMS if in future required. (ALL AHU PANEL WITH 565 In All panel Each starter should have remote control and interlocking facilities including auto manual switch, NO/NC contacts for control and must have auto manual operation suitable to take signal from fire alarm panel for automatic operation of fan in case of fire.All smoke /vent. fan panel the starters shall have suitable facility to operate with fire sensing control modules. 566 Vent. Fan Panel- MCC -1 567 Incoming 568 1 no. 63 amp MCCB 569 Phase indicating lights with control fuses. 570 Breaker ON/OFF/TRIP indicating lights. 571 Bus Bars 572 100 amp TPN Aluminum Bus Bar with heat shrinkable insulation colored sleeves. 573 Outgoings 574 3 nos. 6-10 A,TP MPCB(With DOL Starter) 575 The base frame shall be 75 mm x 5 mm. 576 Panel as described above and in drawings. 577 METER BOARD / SUB PANELS 578 Supplying, Installation, Testing and Commissioning of dust, damp and vermin proof free floor standing / wall mounted factory built sheet steel enclosed modular construction extendable panel, suitable for operation on 415 + 10% volts, 50 Hz AC 3 phase 4 wire system fabricated out of suitable sized square tubular section and covered with 2.0mm thick CRCA sheet, hinged doors of 2mm thick CRCA sheet, duly painted complete with aluminium bus bars, interconnection with solid copper conductor wires / aluminium strips, neutral links, earth bus etc. necessary metering protections & indications and mounted with the following as per drawing and technical specifications attached etc. complete as required. 579 ODUs Panel-01-TERRHVAC 580 Same as above item but outdoor Panel with following accessories. 581 INCOMING: 582 1 No. 200 amps, 415VTPN MCCB with overcurrent and short circuit releases, all indication, push button etc. 583 Coloured (Red, Yellow, Blue) phase indicating lamp - 1 set 584 (0 - 200 A) CT operated Ammeter with selector switch& 3 nos. CTs ratio 200/5A , 15VA burden & accuracy class of 1.0 - 1 set 585 0-500 V Voltmeter with selector switch - 1 set 586 BUSBAR: 587 250 Amp. TPN, 35 kA Al. Bus Bar 588 OUTGOINGS: 589 80A, TPN ELCB with 300mA- 3 Nos. (Incl. 1No. Spare) 590 40A, TPN ELCB with 300mA- 5 Nos. (Incl. 1No. Spare) 591 ODU Panel Described as above/As per Manufacturer ODU Configuration. 592 Spcl. Note : All Above mentionedpanel SITC as per actual GA dwgs. equipments and final config,. Of ODUs. 593 CABLING (POWER ) 594 Power Cabling and Earthing: 595 Spcl. All Cables Should be fire survival Cables (FRLS) 596 Supply, installation, testing & commisioning of LPCB approved mineral insulated copper conductor cables, construction as per BSEN 60702-1:2002 suitable for withstanding 950 deg under fire conditions as per BS 6387 CWZ and 850 deg under fire conditions on one single sample as per BSEN 50200. Cable should be manufactured with seamless copper tube and should be HFLS sheathed. (Tagging to be provided with aluminium strips on both the ends as approved). 597 3Cx10 Sqmm 598 3Cx06 Sqmm 599 3Cx04 Sqmm 600 4Cx06 Sqmm Cu 601 4Cx10 Sqmm Cu 602 Control Cabling 603 Supply, installation, testing & commisioning ofCopper conductor , PVC insulated, PVC sheathed armoured cable of 1.1 KV grade (Which is Interconnecting wiring for the fire alarm system with the AHU and the smoke dampers and AHU to Control Consol Panel). 604 8C x 1.5 Sqmm 605 Supply, installation, testing & commisioning of cable termination of above cables with copper lugs & flameproof brass compression glands on both the ends with inhibting compound etc. complete as required. 606 3Cx10 Sqmm 607 3Cx06 Sqmm 608 3Cx04 Sqmm 609 4Cx06 Sqmm Cu 610 4Cx10 Sqmm Cu 611 Supplying and installing following size of perforated G.I. cable trays, G.I. bends with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with suitable suspenders including G.I. bolts & nuts, painting of suspenders etc. complete as required. 612 100 mm. Width x 50mm. Depth x 1.6mm. Thickness. 613 150 mm. Width x 50mm. Depth x 1.6mm. Thickness. 614 225 mm. Width x 50mm. Depth x 1.6mm. Thickness. 615 Providing and fixing following size of G.I. strip / G.I. wire on surface or in recess for loop earthing alongwith the existing surface/ recessed conduit/ submain wiring / on cable tray/ on surface including G.I. clamps etc. complete as required. 616 6 SWG G.I. wire 617 Electrical work i.e. 618 3 Pin socket switch for Cassette, fcu, inline fan, propeller fan etc. near to the each unit. 619 Isolator Switch (Weather Proof) near to the each ODU. 620 Copper wiring /earthing from Isolator switch to M/C (chillers, pump, AHU , Fan etc.) 621 All DOL Starter Panel and Power cable for Fans/AHU 622 RCC Foundation for chiller, pumps, panels/outdoor units etc.. 623 Spcl. Note:The work includes design, supply, fabrication, erection, testing & commissioning of the complete air conditioning system with items specified above. 624 Supply Installation , Testing & Commissioning of 8 Passangers, 544 Kg. 1mps. Automatic Elevator, with VVVF and Microprocessor based Simplex Collective Selectivewith/without Provision ofattendant control. Separate Landing Push Button Box for all Landings with scrolling indicator. with provision of Attendant control, having 2 stops , 2 Openings with SS Cabin (Hair Line Finish) havingCross flow fan for Ventillation , having sleek (SS hair Line finish-PVC) and LED small Circular lighting all complete. 625 Other Features 626 Battery Operated Emergency Light And Alarm Bell 627 Call Register Signal And Vf Door Operator 628 False Ceiling In Car 629 Vandal Proof S.S. Button With S.S. Cover 630 Firemans Switch 631 Infra Red Door Screen 632 Full Car Operating Panel 633 3 Way Intercom / Press And Speak Phone 634 Push Button - Orange L E D Illumination 635 Dot Matrix Led D & P Indicators In Car & Landings -Orange Colour 636 Automatic Rescue Device 637 Minor Builders Work 638 Scaffolding 639 Floor Annunciator With Music 640 Braille Buttons 641 Sill Support 642 Lift License 643 Overload Warning Indicator With Audio Announcement 644 Pit Ladder 645 Auto Light & Fan Switch Off (Pod) 646 SUB HEAD - I: CIRCUIT CUM POINT WIRING 647 SWITCH CONTROL LIGHT POINTS 648 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 649 Group C 650 MCB CONTROL LIGHT POINTS 651 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Switch Control Primary Points) 652 Primary point controlled by one MCB. 653 Same as item above but Secondary point. i.e. Points to be looped with Primary pointwith 2.5 sqmm wire and Point wiring 654 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 655 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 656 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 657 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 658 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 659 2 x 10 sq. mm + 1 x 10 sq.mm earth wire 660 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 661 4 X 16 sq. mm + 2 X 6 sq. mm earth wire 662 Supplying and fixingsuitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing3 pin 5/6 Amp modular socket outlet and 5/6 A modular switch, connection etc. as required. 663 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 664 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 665 Telephone socket outlet 666 SUBHEAD -II - FITTINGS & FIXTURES 667 Supply, Installation, Testing and Commissioning of 18/20W Wall/Surface mouted 4 ft. LED 668 Supply, Installation, Testing and Commissioning of 40W LED POST TOP LANTERN 669 Supply, Installation, Testing and Commissioning of 40W LED GATE LIGHT 670 Supply, Installation, Testing and Commissioning of9W (Nominal)Wall Bracket Light 671 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019),THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 672 SUBHEAD - III - DISTRIBUTION BOARDS 673 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 674 12 way, Double door 675 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 676 Single Pole 677 Single Pole Neutral 678 Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 679 40 A 680 63 A 681 Supplying and fixing following rating, double pole, (single phaseand neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 682 40 A 683 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Contract Date : Ref. Documents   |   Contract Value : Ref. Documents
Disclaimer

We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.

Tender Detail
Website https://etender.cpwd.gov.in/login.html
Quantity
MSME Exemption No
Tender Type Open Tender
Startup Exemption Click Here
Competitive Bidding NCB
Similar Tenders
TENDER INSIGHTS

858

Electric Tenders
Live
CLICK TO KNOW MAXIMUM WIN

Tell us about your Product / Services,

We will Find Tenders for you

🇮🇳 +91
TenderDetail
Loading tenders