Tender Summary / Eligibility Criteria
Erection of TR Bay, 11kV Panel DP Set erection, control wiring, control room electrification etc work at 66kV MTFL S/S under AM Division Vapi.
Documents
Download All
No Boq
No Corrigendum
Probable Bidders
AI engine predicts probable bidders to help you bid strategically.
MSME Exception
Technical
Tender involves procurement of high capacity electrical equipment including diaphragm coupling of pump &
motor with 90kW capacity at 2900 RPM. The project scope includes installation, testing, commissioning and
operational handover.
Previous / Similar Result
BRR : 1648247
First Phase Renovation Of 66Kv Substation Karimanal-Erection Of 11Kv Panels, Control Wiring And 11Kv Downstream Works
BRR : 7344073
Supply, Erection, Testing and Commissioning of 66kV/11kV,1x6.3MVA Sub-station along with HT/LT switchgears and other related equipment’s including, Equipment Foundation, Cabletrenches, fencing, Construction of Staff Quarters, Control Panel Room, Boundary wall etc for New Industrial Estates (NIE) at Forelain in Kathua District J&K. Package: ESS (Forelain)-R
BRR : 1145829
Procurement Andretrofitting Of 132 Kv/66Kv Isolators/Disconnectors At 132 Kv Sub-Station Shananhep , Pspcl , Joginder Nagar Inclusive Of Dismantlement Of Old Isolators - Erection , Testing And Commissioning Of New Isolators/Disconnectors . Procurement And Retrofitting Of 132 Kv/66Kv Isolators/Disconnectors At 132 Kv Sub-Station Shananhep , Pspcl , Joginder Nagar Inclusive Of Dismantlement Of Old Isolators - Erection , Testing And Commissioning Of New Isolators/Disconnectors . , Supply Of 132 Kv Horizontal Center Break Isolator With Single Earthing Switch ( Line Isolator ) :-Highest System Voltage:- 145 Kv , Rated Current :- 1600 Amp . , Stc:- 31 . 5 Ka For 03 Sec , Operating Mechanism :- Motor Operated , Manually As Well As Local/Remote Operated , Hand Operated Earthing Drive With Interlocking Facility Including Retrofitting Material Suitable For Gantry Mounted Type Alongwith Terminal Connectors . , Supply Of 132 Kv Horizontal Center Break Isolator Without Earthling Switch ( Bus Isolator ) :- Highest System Voltage:- 145 Kv , Rated Current :- 1600 Amp . , Stc:- 31 . 5 Ka For 03 Sec , Operating Mechanism :- Motor Operated Manually As Well As Local/Remote Operated Including Retrofitting Material Suitable For Gantry Mounted Type Alongwith Terminal Connectors . ( Note:- 02 No . Bus Isolator Without Earthing Switch Should Be Suitable For Ground Mounting . ) , Supply Of 66 Kv , Horizontal Double Break Isolator With Single Earthing Switch ( Line Isolator ) :- Highest System Voltage:- 72 . 5 Kv , Rated Current :- 1250 Amp . , Stc:- 31 . 5 Ka For 03 Sec , Operating Mechanism :- Motor Operated , Manually , Hand Operated Earthing Drive With Interlocking Facility Including Supply Of Mounting Structure And Other Material Suitable For Erection Of New Isolator Along With Terminal Connectors . ( Note:- Civil Works Such As Construction Of Foundations For The Erection Of Mounting Structure Shall Be In The Scope Of Pspcl , However Necessary Civil Drawings Will Be Provided By The Bidder . , Design , Manufacture , Supply , Erection , Testing And Commissioning Of Control Panel For The Remote Operation Of 24 No . 132 Kv Isolators From Shanan Control Room Alongwith On/Off Indication And Electrically Interlocking With Existing 132 Kv Sf-6 Breakers Alongwith Supply And Erection Of Control Cables Required For Remote Operation From Control Panel . ( Max . Length Of Cable From Switchyard To Control Room Is 700 Mtr . Appox . ) Alongwith Ferruling , ThimblingAnd Complete Wiring Etc . , Mandatory Recommended Spares For 132 Kv And 66 Kv Isolators Such As Set Of Contacts , Set Of Insulators , Motor , Bearings And Other Mandatory Spares , Dismantlement Of Old/ Existing Isolators And Erection , Testing & Commissioning Of New Isolators Alongwith Erection Of New Mounting/ Fixtures / Structures For All The Isolators And Allied Accessories . , Junction Box , 14Cx2 . 5 Sq Mm Cu . Cable For Control Application . , 7Cx2 . 5 Sq Mm Cu . Cable For Es Control Application . , 2Cx2 . 5 Sq Mm Cu . Cable For Ac Supply , 2Cx2 . 5 Sq Mm Cu . Cable For Dc Supply , 2Cx2 . 5 Sq Mm Cu . Cable For Interlocking
BRR : 35317
Work For Replacement Of Of 11 Kv / 33Kv Vcb, Replacement Of Damaged 11 Kv Xlpe Cable And Erection Of Pole In Long Span And Other Work Under Summer Plan 2022-23 ( Business Plan ) In Jurisdiction Of E.D.D.-Iv, Goverdhan, Mathura.-= 1 Carriage Of 8.5 Mtrs. Long Pcc Pole From 132 Kv Store Center Mathura To Site Of Work Through The Kacha And Pakka Road Including The Work Of Its Loading And Unloading At The Respective Ends Including The Cost Of Arrangement Of Labour, T&P, Carrier Etc. Required For Proper Completion Of Work. ( Distance 00-70Kms. ) 2 Carriage Of Line Material I.E. Conductor, G.I. Wire Tpmo Stay Rod, Disc Insulator, Cross Arm, Angle Channel And Other Required Material From Store Center At 132 Kv Substation Mathura To The Site Of Work Including Loading And Unloading Of Material At Both Ends. 3 Carriage Of 11 Kv Xlpe Cable Size 3X300 Sq.Mm. Cable Form Store Center Mathura / Agra Including Cost Of Shifting Of Drum From Inside Of Store, Removing Of Cable From Drum And Re-Rolling Of Extra Removed Cableincluding Loading & Unloading At Both Ends. 4 Erection Of Single Pole Structure On 8.5 Mtrs Long Pcc Pole Including Fitting Of All Relevant Accessories As Per Respo Norms. 5 Erection Of Double Pole Structure On 8.5 Mtrs. Long Pcc Pole By Digging Of Pits. Opening And Fitting Of All Relevant Accessories As Per Respo Norms. 6 Earthing Of Poles By Fixing Earthing Rods And Binding With Earth Wire As Per Standard Norms Including Cost Of Labour T&P And Required Material For Such Work. 7 Installation Of Stay Set With Grouting And Nuzzling Etc. As Per Respo Drawing / Norms Along With All Routine Material To Be Used For Such Works. 8 Laying, Sagging And Stringing And Jumpering / Binding Etc. Ofnew &Old Acsr Weasel Conductor In 11 Kv / Lt Lines As Per Respo Manual And As Per Direction Of Supervising Engineer Including The Cost Of Arrangement Of Labour, T&P, Carrier Etc. Required For Proper Completion Of Work 9 Laying Of 11 Kv Xlpe Cable Size 3X300 Sq.Mm. In The Trench / G.I Pipe / Hdpe Pipe And Re-Dressing Of Trench After Laying Of Xlpe Cablefor Proper Completion Of Work As Per Direction Of Supervising Engineer. 10 Grouting Of Pcc / St Pole In Ratio 1:4:8 Cement, Sand And Brick Ballast As Per Standard Norms, Including Cost Of All Grouting Material. 11 Fixing Of 11 Kv Cable Indoor Jointing Kit Of Size 3X240 / 3X185 Sq.Mm Including Removal Of Insulation, Semi-Conductor Of The Cable End And Filling Of Cable Box Complete Work As Per Direction Of Supervising Engineer. 12 Fixing Of 11 Kv Cable Box Of Size 3X300 Sq.Mm Including Removal Of Insulation, Semi-Conductor Of The Cable End And Filling Of Cable Box Complete Work As Per Direction Of Supervising Engineer. 13 Safe Loading Of 11Kv V.C.B. In Store Center At 132 Kv S / S Mathura With The Help Of Crain / Hydra Machine Including All Accessories Complete. 14 Carriage Of The New 11Kv V.C.B. From Store Center At 132Kv S / S Mathura To 33 / 11 Kv S / S Anyour In Mathura District As Per Direction Of Supervising Engineer. 15 Safe Unloading Of 11Kv V.C.B. At 33 / 11 Kv S / S Anyour With The Help Of Crain / Hydra Machine Including All Accessories Complete As Per Direction Of Supervising Engineer. 16 Opening Of All Connection Of 11 Kv Existing Panel Ie. Busbar, Wiring Of Each Panel Including Cutting Of Earth Strap With The Help Of Gas Cutter As Per Direction Of Supervising Engineer. 17 Opening Of Existing Cable From Existing Panel To Shifting Of Panel As Per Direction Of Supervising Engineer. 18 Removal Of Old Damaged / Brunt 11Kv V.C.B. From Control Room To Outside Of Control Room Including Opening Of All Connections Ie Cable, Earth Flat And Bus Bar As Per Direction Of Supervising Engineer. 19 Very Carefully Shifting Of 11Kv V.C.B. Panel From Outside Of Control Room Into The Control Room As Per Direction Of Supervising Engineer. 20 Installation Of 11Kv V.C.B. In Control Room At 33 / 11Kv S / S Anyour With Grouting And Making All Connection Ie. Bus Bar Etc. As Per Direction Of Supervising Engineer. 21 Re-Fixing Of Cable In Panel Including Filling Of Cable Box As Per Direction Of Supervising Engineer. 22 Earthing Of V.C.B. Panel / Power T / F By The Chemical Earthing As Per Direction Of Supervising Engineer. 23 Carriage Of 11Kv Damaged V.C.B. Panel From 33 / 11 Kv S / S Anyour Including Loading And Unloading Of Panel At Both Ends As Per Direction Of Supervising Engineer.
BRR : 8644695
Tender For Augmentation Work Of 220/132 Kv, (+) 200 Mva (-) 100 Mva Power Transformerat 220 Kv Gss Rvpn Mandawar (Dausa) - Laying of earth mesh with 25mm / 28mm dia M.S. Rod at a depth of 0.80 metre from top level of foundation, including excavation of trench of required depth and backfilling of the same, transportation of M.S. Rods from site store to location, welding of M.S. Rod to M.S. Rod along the length, at crossings and with earth electrodes as per drawing, application of bitumen compound and covering with bitumen impregnated tape on all welded joints, for the type of soil prevalent at 0.80 metre below top level of foundations (M.S. Rod of above sizes & M.S. Flat as required shall be made available by RVPN).(a) In case electricity is made available by RVPN without charges. i) Any soil, soft rock other than hard rock 2 Laying of earthing risers of 50x6mm / 50x10mm / 50x12mm size M.S. Flat at a depth of 0.80 metre from top level of foundations, including excavation of trench of required depth and back filling of the same, transportation of M.S. Flat from site store to locations, preparation of risers, bending as per reqiurement (after heating if necessary), fixing on & belding / bolting of equipment / structure & peaks of structure, laying in the trench, welding to earth mesh of M.S. Rod as per drawing, including welding of extra length of M.S. Flat if required, application of bitumen compound and covering with bitumen impregnated tape on all welded joints, painting of all surfaces of risers above ground level with red oxide and green paint, for the type of soil prevalent at 0.80 metre below top level of foundations (M.S. Rod of above sizes & M.S. Flat as required shall be made available by RVPN).(a) In case electricity is made available by RVPN without charges.i) Any soil, soft rock other than hard rock 3 Placing / Driving of earth electrode of 25 / 28mm dia. M.S. Rod of length 3.30 metres (approx.) to a depth of 3.80 metres from the top level of foundations, including excavation of pit as required and back filling of the same, transportation of M.S. Rod from site store locations, cutting of M.S. Rod to desire length, preparation of one end as as spike if necessary, welding of earth electrode to earth mesh of M.S.Rod as per drawing, application of bitumen compound and covering with bitumen impregnated tape on all welded joints, for the type of soil prevalent at 3.80 mtrs below top level of foundations (M.S. Rod of above sizes & M.S. Flat as required shall be made available by RVPN).(a) In case electricity is made available by RVPN without charges. i) Any soil, soft rock other than hard rock 4 ERECTION OF SUB-STATION STEEL STRUCTURES columns, beams, lighting mast and equipment structures (excluding Circuit Breakers and Capacitor Banks) of all types including transportation of structure members, nuts & bolts, washers etc from site store to locations, their assembly, placing on foundation, fixing of template, with foundation bolts as required, levelling and preparing for grouting as required, but excluding grouting, erection after grouting and tightening & punching of nuts & bolts. (Maximum height of structures up to 20 metres) 5 STRINGING of 220KV, 132KV, 33KV & 11KV Bus Bar of ACSR & Tarantulla conductor including transportation of conductor, disc insulator & tension hardware from site store to location, laying & cutting required length of conductor, cleaning & assembly of disc insulators as required along with fitting of bolted type or compression type tension hardware as made availablebetween the beams with specified sag and tension, also equilising sag and fitting spacers and spacer T-clamps for twin conductor for three phase of conductors in each sub-section.(Per jumper basis) i) Any Single Conductor 6 STRINGING of 220KV, 132KV, 33KV & 11KV Bus Bar of ACSR & Tarantulla conductor including transportation of conductor, disc insulator & tension hardware from site store to location, laying & cutting required length of conductor, cleaning & assembly of disc insulators as required along with fitting of bolted type or compression type tension hardware as made availablebetween the beams with specified sag and tension, also equilising sag and fitting spacers and spacer T-clamps for twin conductor for three phase of conductors in each sub-section.(Per jumper basis)i) Any Double Conductor 7 JUMPERS of ACSR conductor (3 nos. Y-type) between bus to equipment or between equipment to equipment or between bus to bus, including transportation of conductor, disc insulators and hardware from site stores to locations, cleaning & assembly of disc insulators as required along with fitting of suspension hardware and erection as required length of conductor, making connections, fixing of spacers & spacer T-clampsas required, tightening of clamps / connectors, dressing etc., for three phases.(Per jumper basis) 8 STRINGING of earth wire (size 7/3.15 mm or 7/4.00 mm) including transportation of earth wire, tension hardwares etc from site store to locations, laying and cutting required length of earth wire, fitting of bolted type or compression type hardware as made available (compression machine shall be provided by RVPN on rent free basis) making up at one end, stringing of earthwire between structure peaks with specified sag and tension, jumpering and connecting earth bonds for single earthwire. 9 Erection of Current Transformer / Potential Transformer / Capacitive Voltage Transformer / Series Reactor / Residual Voltage Transformer / Neutral Current Transformer with clamps & connectors on already erected steel structure including transportation from site store to locations, fabrication of base frame, fixing of terminal connectors, tightening of nuts & bolts etc, complete in all respects. i) 220 KV CT / PT / CVT 10 Erection of Current Transformer / Potential Transformer / Capacitive Voltage Transformer / Series Reactor / Residual Voltage Transformer / Neutral Current Transformer with clamps & connectors on already erected steel structure including transportation from site store to locations, fabrication of base frame, fixing of terminal connectors, tightening of nuts & bolts etc, complete in all respects. ii) 132 KV CT / PT / CVT 11 Erection of Lightening Arrestor on already erected steel structure including transportation of Lightening Arrestor, clamps & connectors, surge counter etc from site store to locations, fabrication of base frame, fixing of terminal connectors, surge counter, tightening of nuts & bolts etc, complete in all respects.ii) 220 KV 12 Erection of Lightening Arrestor on already erected steel structure including transportation of Lightening Arrestor, clamps & connectors, surge counter etc from site store to locations, fabrication of base frame, fixing of terminal connectors, surge counter, tightening of nuts & bolts etc, complete in all respects.ii) 132 KV 13 Erection of 220 KV Isolators (Motorised/ Non motorised) on already erected steel structure including transportation of base frame, P Is contacts, mechanism box, clamps & connectors etc from site store to locations, minor fabrication as required and fixing of terminal connectors etc, adjustment / alignment of isolator and its earth blade, if provided for their smooth operation and final adjustment if required after jumpering including erection of PI.a) Without Earth Blade 14 Erection of 1220 KV Isolators (Motorised/ Non motorised) on already erected steel structure including transportation of base frame, P Is contacts, mechanism box, clamps & connectors etc from site store to locations, minor fabrication as required and fixing of terminal connectors etc, adjustment / alignment of isolator and its earth blade, if provided for their smooth operation and final adjustment if required after jumpering including erection of PI.a) Tandem 15 Erection of 132 KV Isolators (Motorised/ Non motorised) on already erected steel structure including transportation of base frame, P Is contacts, mechanism box, clamps & connectors etc from site store to locations, minor fabrication as required and fixing of terminal connectors etc, adjustment / alignment of isolator and its earth blade, if provided for their smooth operation and final adjustment if required after jumpering including erection of PI.b) WithoutEarth Blade 16 Erection of 220 KV or 132 KV Circuit Breaker including transportation of equipments, structure members, nuts & bolts, clamps & connectors etc from site store to locations, assembly of support structure, their placing on foundation, levelling and preparing for grouting as required, but excluding grouting, assembly / placing of support coulmns / poles, mechanism box / control cubicle, and other accessories as per manufacturers drawings, fitting of SF6 gas pipeline, fabrication of air/ oil pipeline as required, electrical wiring from pole to control cubicle, fixing of terminal connectors as required, but excluding commissioning of CB for all types of operating mechanism as required. (i) 220 KV 17 Erection of 220KV Class EHV Transformer (Gas filled tankalready placed on foundation with wheels) including transportation of accessories from site store to locations, erection of HV, IV, LV & Neutral bushings, main & OLTC conservators, radiators, equilizing pipe line, marshalling kisok etc as per manufacturers drawing, preparation of oil, oil filling, dehydration of transformer (filter machine, oil tank & operating staff shall be provided by RVPN), electrical wiring from individual equipment e.g. Buchholz Relay, MOLG, OSR etc to marshalling kiosk etc but excluding testing & commissioning of transformer.(a) If electricity is available & arranged by RVPN without charges. i) Transformer received Oil filled 18 ERECTION OF CONTROL & RELAY PANALS complete in all respects including transportation from site store to control room, placing on foundation / cable trench as per layout, interconnection between Control & Relay panels and with existing panels, fixing of side / top covers and doors, earthing to existing earth strip in control room, connection of bus wiring to existing panel and between control and relay panel as required.ii) Duplex Panel 19 ERECTION OF CONTROL & RELAY PANALS complete in all respects including transportation from site store to control room, placing on foundation / cable trench as per layout, interconnection between Control & Relay panels and with existing panels, fixing of side / top covers and doors, earthing to existing earth strip in control room, connection of bus wiring to existing panel and between control and relay panel as required. iii) Simplex Panel, DC Panel, RTCC Panel, PLCC Panel etc 20 ERECTION OF MARSHALLING KIOSK / Line Matching Unit (LMU) / Line Matching & Distribution Unit (LMDU) complete in all respect including transportation from site store to location, placing on foundation / cable trench as per layout, preparing for grouting of foundation bolts but excluding grouting etc. i) 220 KV or 132 KV Marshlling Kiosk 21 i) Laying of PVC insulated unarmoured / armoured control cables of 1.1 KV grade with copper conductor in cable trenches as per specification as required, including transportation of cable drums from site store to locations, laying in cable treches, cutting of required length, placing them on cable racks / cable trays / cable batten & dressing, including removing and re-fixing trech covers as required , making necessary connections, testing, cable marking on both the terminating ends etc as required for all sizes from 2C x 2.5 sq. mm. to 20C x 2.5 sq. mm, 4C x 4 sq. mm and 4C x 6 sq. mm.a) Unarmoured control cable 22 ii) Fixing of control cable in position with single compression nickel plated brass cable glands confirming to IS: 12943 & having three metal washers and one rubber ring, including preparation of cable and drilling of corresponding holes in gland plates etc as required & including cost of cable glands for each cable gland size a) 19 mm unarmoured control cable 23 ii) Fixing of control cable in position with single compression nickel plated brass cable glands confirming to IS: 12943 & having three metal washers and one rubber ring, including preparation of cable and drilling of corresponding holes in gland plates etc as required & including cost of cable glands for each cable gland sizec) 25 mm unarmoured control cable 24 iii) Termination of wires of cables with copper conductor using copper terminal ends (pin or ring type as required of Dowells or equivalent make as approved by the Engineer - In - Charge) duly crimped with crimping tool, including making wire ends ready for crimping, ferruling & dressing of wires etc as required including cost of terminal ends for all wires for each cable at both ends for cables of the following sizes.a) 2.5 Sqmm for any number of core 25 iii) Termination of wires of cables with copper conductor using copper terminal ends (pin or ring type as required of Dowells or equivalent make as approved by the Engineer - In - Charge) duly crimped with crimping tool, including making wire ends ready for crimping, ferruling & dressing of wires etc as required including cost of terminal ends for all wires for each cable at both ends for cables of the following sizesb) 4 Sqmm for any number of core 26 Dismentaling of 220KV, 132KV, 33KV & 11KV Bus Bar of ACSR & Tarantulla conductor including transportation of conductor, disc insulator & tension hardware from site store to location, laying & cutting required length of conductor, cleaning & assembly of disc insulators as required along with fitting of bolted type or compression type tension hardware as made availablebetween the beams with specified sag and tension, also equilising sag and fitting spacers and spacer T-clamps for twin conductor for three phase of conductors in each sub-section.(Per jumper basis) 27 Dismentaling of JUMPERS of ACSR conductor(3 nos Y type)between equipment or between bus to bus,including transportion of conductor,disc insulators and hardware from site stores to locations ,cleaning and assembly of disc insulators as along with fitting of suspension hardware and erectoin as reqired, cutting reqired length of conductor, making connections,fixing of spacers & spacer T-clamps as reqired,tightiening of clamps/connectors,dressing ect. For three phases.(Per jumper basis) any conductor 28 DISMENTELLING of Current Transformer / Potential Transformer / Capacitive Voltage Transformer / Series Reactor / Residual Voltage Transformer / Neutral Current Transformer with clamps & connectors on already erected steel structure including transportation from site store to locations, fabrication of base frame, fixing of terminal connectors, tightening of nuts & bolts etc, complete in all respects. 220 KV CT/PT/CVT 29 DISMENTELLING of Current Transformer / Potential Transformer / Capacitive Voltage Transformer / Series Reactor / Residual Voltage Transformer / Neutral Current Transformer with clamps & connectors on already erected steel structure including transportation from site store to locations, fabrication of base frame, fixing of terminal connectors, tightening of nuts & bolts etc, complete in all respects. 132 kvCT/PT/CVT 30 Dismental of lightening Arrestor on already erected steel structure including transportion of lighting Arre-stor,clamps&connectors,surge counter etc. from site store to locations fabrication of base frame,fixing of terninal connectors surge counter, tighting of nuts&bolts etc. complete in all respect. (I) 220 kv 31 Dismental of lightening Arrestor on already erected steel structure including transportion of lighting Arre-stor,clamps&connectors,surge counter etc. from site store to locations fabrication of base frame,fixing of terninal connectors surge counter, tighting of nuts&bolts etc. complete in all respect. (ii) 132 KV 32 DISMENTELLINGof Isolators (Motorised/ Non motorised) on already erected steel structure including transportation of base frame, P Is contacts, mechanism box, clamps & connectors etc from site store to locations, minor fabrication as required and fixing of terminal connectors etc, adjustment / alignment of isolator and its earth blade, if provided for their smooth operation and final adjustment if required after jumpering including erection of PI. (I) 220 KVWITHOUT EARTH BLADE 33 DISMENTELLINGof Isolators (Motorised/ Non motorised) on already erected steel structure including transportation of base frame, P Is contacts, mechanism box, clamps & connectors etc from site store to locations, minor fabrication as required and fixing of terminal connectors etc, adjustment / alignment of isolator and its earth blade, if provided for their smooth operation and final adjustment if required after jumpering including erection of PI. (I) 220 KVTANDEM 34 DISMENTELLINGof Isolators (Motorised/ Non motorised) on already erected steel structure including transportation of base frame, P Is contacts, mechanism box, clamps & connectors etc from site store to locations, minor fabrication as required and fixing of terminal connectors etc, adjustment / alignment of isolator and its earth blade, if provided for their smooth operation and final adjustment if required after jumpering including erection of PI. (I) 132 kv w/o EARTH BALDE 35 Dismentalof 220 KV Circuit Breaker including transportation of equipments, structure members, nuts & bolts, clamps & connectors etc from site store to locations, assembly of support structure, their placing on foundation, levelling and preparing for grouting as required, but excluding grouting, assembly / placing of support coulmns / poles, mechanism box / control cubicle, and other accessories as per manufacturers drawings, fitting of SF6 gas pipeline, fabrication of air/ oil pipeline as required, electrical wiring from pole to control cubicle, fixing of terminal connectors as required, but excluding commissioning of CB for all types of operating mechanism as required. 36 Dismantlingof 220 KV Class EHV Transformer (Gas filled tank already placed on foundation with wheels ) including transportation of Accessories from site store to location , Erection of HV , IV , LV & Netural bussing tank already placed on foundation with wheels) including transportation of accessories from site store to locations, erection of HV, IV, LV & Neutral bushings, erection of cooler bank with associated pipe line , radiators , fans , pumps main & OLTC Conservators , Equalizing pipe line , marshalling Kisosk , etc. as per manufacturers drawing prepration of oil , oil filling , dehydration of transformer along with cooler bank & diverter switch(filter machine, oil tank & operating staff shall be provided by RVPN), electrical wiring from individual equipment e.g. Buchholz Relay, MOLG, OSR etc to marshalling kiosk etc but excluding testing & commissioning of transformer. 37 Dismentling ofCONTROL & RELAY PANALS complete in all respects including transportation from site store to control room, placing on foundation / cable trench as per layout, interconnection between Control & Relay panels and with existing panels, fixing of side / top covers and doors, earthing to existing earth strip in control room, connection of bus wiring to existing panel and between control and relay panel as required. Duplex panel 38 Dismentling ofCONTROL & RELAY PANALS complete in all respects including transportation from site store to control room, placing on foundation / cable trench as per layout, interconnection between Control & Relay panels and with existing panels, fixing of side / top covers and doors, earthing to existing earth strip in control room, connection of bus wiring to existing panel and between control and relay panel as required. 9ii) Simplex Panel, DC Panel, RTCC panel, PLCC Panel etc
Disclaimer
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tender Detail
| Website | https://tender.nprocure.com/ |
| Quantity | |
| MSME Exemption | No |
| Tender Type | Open Tender |
| Startup Exemption | Click Here |
| Competitive Bidding | NCB |
TENDER INSIGHTS
858
Electric TendersLive
Tell us about your Product / Services,