TDR : 56552626
Gujarat Energy Transmission Corporation Limited

Tender Brief :

Mehsana, Gujarat

Tender For Bi-Annual Rate Contract for providing fixing of 11 KV XLPE cable termination kit at Various s/s under GETCO, Mehsana Circle.

Published: 18 Jul 2026
Opening: Ref Document
Closing: 10 Aug 2026
Amount: 14.85 Lakhs
EMD: 14850
Tender Fee: 1180


Works Active Harmonic Filter Actuator Aerial Cable Aerodrome Beacon Air Circuit Breaker
9
Days Left
Tender Summary / Eligibility Criteria
Bi-Annual Rate Contract for providing fixing of 11 KV XLPE cable termination kit at Various s/s under GETCO, Mehsana Circle.
Documents Download All
7505dc57947d40f29f938c1acc701f82
7505dc57947d40f29f938c1acc701f82.html
TenderDocuments44
TenderDocuments44.pdf
No Boq
No Corrigendum
Probable Bidders

AI engine predicts probable bidders to help you bid strategically.

MSME Exception
Explore More →
Technical
Tender involves procurement of high capacity electrical equipment including diaphragm coupling of pump & motor with 90kW capacity at 2900 RPM. The project scope includes installation, testing, commissioning and operational handover.
Previous / Similar Result
BRR : 3228161 Biennial Rate Contract For Executing Various Schemes Such As Provision Of Street Lights, Shifting / Removal Of Street Lighting Poles With Fixtures, Improvement Of Street Lighting Systems Etc. Prepared By Street Lighting Construction Department-2 Installation Of Ms Galvanized Pole Of Height 5 Mtrs. With Burial Foundation 3 Installation Of Ms Galvanized Pole Of Height 7 Mtrs With Burial Foundation 4 Installation Of Ms Galvanized Pole Of Height 9 Mtrs With Burial Foundation 5 Installation Of Ms Galvanized Pole Of Height 14.5 Mtrs With Burial Foundation 6 Installation Of Ms Galvanized Pole Of Height 7 / 9 Mtrs On Flyover & Bridges 7 Installation Of Ms Gi Arm Bracket 1220×81 Single Arm 8 Installation Of Ms Gi Arm Bracket 1220×81 Double Arm 9 Installation Of Ms Gi Arm Bracket 1830×94 Single Arm 10 Installation Of Ms Gi Arm Bracket 1780×120 Double Arm 11 Installation Of Ms Gi Arm Bracket 1830×94 Double Arm 12 Installation Of Ms Gi Arm Bracket 1830×94 Quadra Arm / Triple Arm 13 Installation Of Ms Gi Arm Bracket 600×94 Six Way Arm 14 Installation Of Bracket Ms Gi Arm 600×120 Six Way Arm 15 Installation Of Decorative Lantern 15 W On 5 Mtr Pole With Wiring 16 Installation Of Lantern 50 W / 105W / 150W On 5 / 7 Mtrs Pole With Wiring 17 Installation Of Lantern 105 W / 150W / 170W On 9 Mtrs Pole With Wiring 18 Installation Of Lantern 170 W On 14.5 Mtrs Pole With Wiring 19 Installation Of Lantern 210W / 270 W On 9 / 14.5 Mtrs Pole With Wiring 20 Installation Of M.S. G.I. C-Clamp With 2 Feet Arm In Size 600 Mm Bracket For 7 / 9 / 14.5Mtrs Pole 21 Installation Of Switch Box On Pole 22 Laying Of Earthing Pipe 23 Excavation And Laying Of Cables Between Poles On Kutccha Surface 24 Excavation And Laying Of Cables Between Poles On Roads 25 Excavation And Laying Of Cables Between Poles On Footpath ( Paver Block ) 26 Excavation And Laying Of Cables Between Poles On Concrete Surface 27 Fixing Of Existing Cable Gland Termination To Switch Box 28 Fixing Of New Gland Termination With 25 / 4C Xlpe Cable To Switch Box 29 Fixing Of New Gland Termination With 300 / 4C Xlpe Cable In New Street Light Pillar 30 Cable Pulling Through Hdpe Pipe Id 67 Mm. 31 Installation Of New Street Lighting Pillar With Precast Foundation 32 Removal Of Existing Street Light Pillar With Various Cable Terminations ( Approx. 4 Terminations ) 33 Removal Of Lantern 15W From 5 Mtrs Pole 34 Removal Of Lantern 50W From 5 / 7 Mtrs Pole 35 Removal Of Lanterns 105W / 170W / 150W / 210W / 270W From 9 Mtrs Pole 36 Removal Of Lanterns 170W / 150W / 210W / 270W From 14.5Mtrs Pole 37 Removal Of Bracket For 5 / 7 Mtrs Pole 38 Removal Of Bracket For 9 / 14.5 Mtrs Pole 39 Removal Of Switch Box 40 Removal Of Cables By Pothead Or Straight Jointing 41 Removal Of Pole 5 Mtrs 42 Removal Of Pole 7 Mtrs 43 Removal Of Pole 9 Mtrs 44 Removal Of Pole 14.5 Mtrs 45 Removal Of Pole 7 / 9 Mtrs From Flyover & Bridges 46 Installation Of Flood Lantern With Fixing Angel Bracket 47 Fixing Additional Switch Box On Pole And Looping Wire Between Existing Switch Box And New Switch Box 48 Focus Adjusting Of Lantern As Per Requirement. 49 Jointing Of Cables Wherever Required Of 300 / 4C Xlpe Cable 50 Jointing Of Cables Wherever Required Of 25 / 4C Xlpe Cable 51 Making Permanent Pothead Or Sealing The Cable 300 / 4C Xlpe Cable 52 Making Permanent Pothead Or Sealing The Cable 25 / 4C Xlpe Cable 53 Installation Of New Street Light Pillar 54 Removal Of Existing Street Light Pillar
Contract Date : 02 Jun, 2023   |   Contract Value : 9.20 Crore
BRR : 11213037 Tender for Rate Contract For Supply, Installation, Testing, Commissioning And Maintenance Of Hybrid Lan, & Ups Wiring In Various Hospitals Across Kerala Under E-Health Project.(Network Passive And Electrical Components) , Outdoor O. F. Cable 6 Core Sm , 24 Port Fully Loaded Liu Rack Mountable , 12 Port Fully Loaded Liu Rack Mountable , 6 Port Fully Loaded Liu Rack Mountable , Lc To Sc Patch Cord. Sm , Lc To Lc Patch Cord. Sm , Sc To Sc Patch Cord. Sm , Cat6 4 Pair Utp Cable: 23 Awg , Cat 6 Stp Out Door Cable , Cat6 Information Outlet , Face Plate Singlex.- Cat6 , 3 X 3 Surface Mount Box For Cat6 Outlet , Cat6 Patch Cord,3 Mtr , Cat6 Patch Cord, 1 Mtr , Cat6 Patch Panel 24 Port Fully Loaded , Cat6a 4 Pair Utp Cable: 23 Awg , Cat6a Information Outlet , Face Plate Singlex.- Cat6a , Cat6a Patch Cord,3 Mtr , Cat6a Patch Cord, 1 Mtr , Cat6a Patch Panel 24 Port Fully Loaded , 27U Floor Mount Rack With Accessories , 15U Wall Mount Rack With Accessories , 12U Wall Mount Rack With Accessories , 9U Wall Mount Rack With Accessories , 6U Wallmount Rack With Accessories , Supply Of Cable Route Marker With Angle Iron Leg 2 Ft With Painting , Supply Of 25Mm Isi Pvc Conduit- Ivory , Dlp Trunking With Accessories 100X50 , Supply Of 32 Mm Hdpe Pipe , 1.5/ 2 Gi Pipe Isi Approved , Supply Of The Following 1100V, Aluminium Cable, Xlpe / Ayfy In The Existing Cable Trenches/Cable Trays / Pipes/ Etc. Including Supply And Fixing Of Necessary Clamping Materials. 2 X 10 Sq.Mm , 415 V , 2 X 16 Sq.Mm , 415 V , 4 X 25 Sq.Mm , 415 V , 4 X 16 Sq.Mm , 415 V , Supply Of All Materials For Termination Of The Following Pvc Insulated Armoured Aluminium Lt Cables (Ayfy/A2xfy) Using Single Compression Type Cadmium Plated Brass Cable Glands , Copper Crimped Type Cable Lugs, Cable Identification Tags And Including Gland Earthing Using Copper Conductor Of Adequate Size,Al-Cu Strip For Termination Of Cables Etc. 2 X 10 Sq.Mm , 415 V , 2 X 16 Sq.Mm , 415 V , 4 X 25 Sq.Mm , 415 V , 4 X 16 Sq.Mm , 415 V , Supply
Contract Date : Ref. Documents   |   Contract Value : Ref. Documents
BRR : 11087677 Tender for E-Quotation For Seeking Firm Rates Of Plant & Machinery And Materials Category Items For Preperation/Amendment Of Schedule Of Rate For The Year 2026. , M 1055 - Pumps Supplying Submersible Pump Sets Confirming To Is 8034 And Motor Confirming To Is 9283. Pump Shall Be Suitable For Various Delivery Head And Discharge With Stainless Steel Pump Shaft And Polypropylene/ Noryl Impeller. Motor Suitable For Working On 415V+10%, 3Ph, 50 Hz, A.C. Supply With Cable Guard, Thrust Carbon/ Fiber Bearing To Withstand Entire Hydraulic Thrust, Water Proof Winding Shall Be Provided. The Pump Set Shall Be Suitable For Direct Coupling. Pump Shall Have Suitable Outlet As Per Manufacturers Design. Anti Thrust Stream Lined Non Return Valve Shall Be Provided With Pump. 3 Meter Submersible Copper Conductor Cable In Single/ Double Run Shall Be Provided With Each Pump. , Submersible Pump Set 100 Mm Dia (With Polypropylene/ Noryl Impeller) Up To 20 Stages 1 H.P. , 1.5 Hp , 2.5 Hp , 3.0 Hp , 4.0 Hp , 5.0 Hp , Submersible Pump 150 Mm Dia (With Bronze/Ss Impeller) Up To 8 Stages , 1.5 Hp , 2.0 Hp , 3.0 Hp , 4.0 Hp , 5.0 Hp , 6.0 Hp , 7.5 Hp , M 1056 - Pressure Guage Providing Fabricating, Testing And Commisioning Pressure Vessel Fabricating In M.S Plate On Providing Foundation Including Epoxy Paint , Pressure Gauge (100 Mm Dia) , Pressure Gauge (150 Mm Dia) , Vacuum / Combination Gauge , M 1057 - Lifting Equipment Chain Pulley Block Supplying Triple Spur Gear Type Chain Pulley Block Suitable For Capacity As Below With 3 M Lift Complete With Load Chain And Hand Chain Suitable For Above Lift, Tested To 50% Over Load As Per Is 3832 Carrying Isi Mark. , 1 Tonne Capacity , 2 Tonne Capacity , 3 Tonne Capacity , Electric Operated Circular Or Rectangular Travelling Crane (Single Girder) Supplying Single Girder Electrically Operated Rectangular Over Head Travelling Crane With 6 M Lift Complete With Wire Rope Hoist, Class Ii Duty, All Three Motions Electrically Operated By Suitable Rating Motor Ip 54, Control Panel And Down Pendant Control Block. , 5 Tonne Capacity , Above 6 M Up To 8 M Span , Above 8 M Up To 10 M Span , 7.5 Tonne Capacity , Above 6 M Upto 8 M Span , Above 8 M Up To 10 M Span , 10 Tonne Capacity , Above 6 M Up To 8 M Span , Above 8 M Up To 10 M Span , M 1058 - Lightening Arrester, Ab Switch, Insulators , Lightening Arrestor Supplying, Erecting Approved Make Thyrite Type Lightening Arrestor Suitable For H.T. Supply With Necessary Ancillary Material Complete On Provided Cross Arm And Connected To Overhead Line. , Suitable For 11 Kv Supply, Distribution Class , Suitable For 22 Kv Supply, Distribution Class , Suitable For 33 Kv Supply, Station Class , Disc Insulator. Supplying, Erecting Porcelain Disc Type Insulators With Hardware Fittings Suitable For H.T. Overhead Line Complete Erected With Nuts And Bolts On Provided Cross Arm , Suitable For 11Kv Line , Suitable For 33Kv Line , Pin Insulator Supplying, Erecting Porcelain Pin Type Insulators With Hardware Fittings Suitable For H.T. Overhead Line Complete Erected With Nuts And Bolts On Provided Cross Arm , Suitable For 11Kv Line , Suitable For 33Kv Line , Air Break Switch Without Earth Switch Supplying, Erecting Approved Make H.T. Outdoor Type Gang Operated Air Break Triple Pole Switch Of Required Capacity With 3 Post / Pin Type Insulator Per Phase , Mounted In Horizontal Or Vertical Position On Provided Cross Arm With Adequate Length Of G.I. Pipe For Operating Handle Erected On Extended Square Shaft. The Operating Handle Provided With Lock And Key At Suitable Height From Ground With Necessary Clamps , Suitable For 11Kv Line , Rocking / Tilting Type , Rotating Type , Suitable For 33Kv Line , Rocking / Tilting Type , Rotating Type , Air Break Switch With Earth Switch Supplying, Erecting Approved Make H.T. Outdoor Type Gang Operated Air Break Triple Pole Switch With Earth Switch Of Required Capacity With 3 Post / Pin Type Insulator Per Phase , Mounted In Horizontal Or Vertical Position On Provided Cross Arm With Adequate Length Of G.I. Pipe For Operating Handle Erected On Extended Square Shaft. The Operating Handle Provided With Lock And Key At Suitable Height From Ground With Necessary Clamps , Suitable For 11 Kv Line , Rotating Type , Suitable For 33 Kv Line , Rotating Type , Drop Out Fuse (Channel Mounted) Supplying, Erecting Approved Make Out Door Type Drop Out Fuse Channel Type With Insulator Complete With Fuse Holders Fuse Barrel With Metal Fittings, Fuse Element, With Working Current Up To 50 Amp, Capacity Complete Erected On Provided Cross Arm, Each Set Comprising 3 Units , Suitable For 11 Kv Line , Suitable For 33 Kv Line , Horn Gap Fuse (Channel Mounted) Supplying, Erecting Approved Make Out Door Type Horn Gap Type Fuse With Insulator, Fuse Element, With Working Current Up To 50 Amp, Capacity Complete Erected On Provided Cross Arm, Each Set Comprising 3 Units , Suitable For 11 Kv Line , Suitable For 33 Kv Line , M 1059 - Transformer Power Transformer (With Off Load Tap Changer) Any Isi Mark , Supplying Outdoor Type Copper Wound Transformer Continuously Rated For 3Ph, 50 Hz, At Full Load And Temp. Rise Not Exceeding 45 Degree C By Thermometer In Oil And 50 Degree C By The Resistance In Winding After Continuous Run At Full Load Rating, The Transformer Should Have Oil Immersed Winding Having Vector Group Dy11, Ht Side Connected In Delta And Lt Side Connected In Star With Neutral Brought Out Connected To Provide Separate Earthing. The Transformer Shall Have Power Terminal Arrangement, Bushing/ Cable End Box On Ht Side And Cable End Box On Lt Side. 2 Nos Channels With Stoppers Shall Be Provided And Fixed On The Provided Plinth For Mounting The Transformer. The Transformer Should Have Following Standard Fittings. Transformer Shall Be Latest Manufacturing Standards As Per Amended Is Specifications And The Load & No Load Losses Shall Be Limited To The Values Given Below Or As Per Is Or Norms Issed By Seb Which Ever Are Lower- 1. Oil Conservator With Filling Hole With Cap And Plain Oil Level Gauge. 2. Silica Gel Dehydrating Breather Charged With Silica Gel. 3. Oil Drain Valve 4. Oil Filter Valve 5. Lifting Eyes/ Hooks 6. Two Earthing Terminals 7. Diagram And Rating Plate 8. Air Vent 9. Explosion Vent 10. 100Mm Dia Thermo Meter With Thermometer Pocket 11. Four arc-biannual rate contract Directional Plain Roller. , Power Transformer 11000/433 Volts With Off Load Tap Changer - 12.5% To +2.5% In Steps Of 2.5% As Per Bis Level-2. , 63 Kva , 100 Kva , 160 Kva , 200 Kva , 250 Kva , 315 Kva , 500 Kva , 630 Kva , 750/800 Kva , Power Transformer (With On Load Tap Changer) Supplying Outdoor Type Copper Wound Transformer Continuously Rated For 3Ph, 50 Hz, At Full Load And Temp. Rise Not Exceeding 45 Degree C By Thermometer In Oil And 50 Degree C By The Resistance In Winding After Continuous Run At Full Load Rating, The Transformer Should Have Oil Immersed Winding Having Vector Group Dy11, Ht Side Connected In Delta And Lt Side Connected In Star With Neutral Brought Out Connected To Provide Separate Earthing. The Transformer Shall Have Power Terminal Arrangement, Bushing/ Cable End Box On Ht Side And Cable End Box On Lt Side. 2Nos Channels With Stoppers Shall Be Provided And Fixed On The Provided Plinth For Mounting The Transformer. The Transformer Should Have Following Standard Fittings. The Oltc Should Be Suitable For Minimum 50 Operations Per Day. Transformer Shall Be Latest Manufacturing Standards As Per Amended Is Specifications And The Load & No Load Losses Shall Be Limited To The Values Given Below Or As Per Is Or Norms Issued By Seb Which Ever Are Lower- , 1. Oil Conservator With Filling Hole With Cap And Plain Oil Level Gauge. 2. Silica Gel Dehydrating Breather Charged With Silica Gel. 3. Oil Drain Valve 4. Oil Filter Valve 5. Lifting Eyes/ Hooks 6. Two Earthing Terminals 7. Diagram And Rating Plate 8. Air Vent 9. Explosion Vent 10. 100Mm Dia Thermo Meter With Thermometer Pocket 11. Four arc-biannual rate contract Directional Plain Roller. 12. Buchholz Relay 13. Resistance Temp. Detector 14. Marshalling Box 15. Automatic Voltage Regulator (Avr) 16. Remote Tap Changing Controller (Rtcc) , Transformer 11000/433 Volts With On Load Tap Changer - 15% To +5% In Steps Of 1.25% With Rtcc, Avr And Marshalling Box And Other Specification , 750/800 Kva , 1000 Kva , 1250 Kva , 1600 Kva , 2000 Kva , M 1060 - Motors Foot Mounted Motors Tefc 1500 Rpm Supplying Foot Mounted Tefc 1500 Rpm, Squirrel Cage Induction Motor, Conforming To Is 325 Having Continuous Rating Suitable For Operation At 415 Volts ± 10%, 3 Phase, 50 Hz ± 3% With F Class Insulation Temperature Rise Limited To Class B Insulation. Motors Conform To Is-12615 With Efficiency Level Ie3 And Provided With Enclosure Protection Class Ip-55. , 15 Kw (20 Hp) , 18.5 Kw ( 25 Hp) , 22 Kw ( 30 Hp) , 30 Kw ( 40 Hp) , 37 Kw ( 50 Hp) , 45 Kw ( 60 Hp) , 55 Kw ( 75 Hp) , 75 Kw ( 100 Hp) , 90 Kw ( 120 Hp) , 110 Kw ( 150 Hp) , 132 Kw ( 180Hp ) , 160 Kw ( 215 Hp ) , M 1061 - Aluminium Cable Cable - Aluminium Conductor Three Core, Xlpe / Pvc Insulated & Armoured Cable . Supplying Xlpe / Pvc Insulated, Armoured Cable 1100 V Grade With Isi Mark Three Core, Solid / Stranded Aluminium Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Complete In An Approved Manner. , 3 Core 2.5 Sq Mm , 3 Core 4 Sq Mm , 3 Core 6 Sq Mm , 3 Core 10 Sq Mm , 3 Core 16 Sq Mm , 3 Core 25 Sq Mm , 3 Core 35 Sq Mm , 3 Core 50 Sq Mm , 3 Core 70 Sq Mm , 3 Core 95 Sq Mm , 3 Core 120 Sq Mm , 3 Core 150 Sq Mm , 3 Core 185 Sq Mm , 3 Core 240 Sq Mm , 3 Core 300 Sq Mm , 3 Core 400 Sq Mm , Ht Aluminium Three Core 3.3 Kve Cable Xlpe Insulated Supplying Ht Aluminium Three Core Cable Xlpe Insulated ,Insulation Screened With Extruded Semi Conducting Compound In Combination With Copper Tape (0.3 Ka For 1 Sec.) Cores Laidup Inner Sheath Of Pvc Tape ,Galvanised Steel Flat Strip Armoured,And Overall Pvc Sheathed Cable Conforming To Is :7098 /Ii/85 With Latest Amendments , 3 Core 70 Sq Mm , 3 Core 95 Sq Mm , 3 Core 120 Sq Mm , 3 Core150sq Mm , 3 Core 185 Sq Mm , 3 Core 240Sq Mm , 3 Core 300 Sq Mm , 3 Core 400 Sq Mm , M 1062 - Copper Cable Cable , 3 Core Pvc Insulated, Pvc Sheathed Copper Conductor Flat Submersible Cable . Supplying , Flat Flexible Submersible Cable With, Copper Conductor, Pvc Insulated, And Pvc Sheathed . , 3 Core 1.5 Sq Mm , 3 Core 2.5 Sq Mm , 3 Core 4 Sq Mm , 3 Core 6 Sq Mm , 3 Core 10 Sq Mm , 3 Core 16 Sq Mm , 3 Core 25 Sq Mm , 3 Core 35 Sq Mm , Copper Conductor Three Core, Xlpe / Pvc Insulated & Unarmoured Cable Supplying Xlpe / Pvc Insulated, Unarmoured Cable 1100 V Grade With Isi Mark Three Core, Solid / Stranded Copper Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Complete In An Approved Manner. , 3 Core 1.5 Sq Mm , 3 Core 2.5 Sq Mm , 3 Core 4 Sq Mm , 3 Core 6 Sq Mm , 3 Core 10 Sq Mm , 3 Core 16 Sq Mm , 3 Core 25 Sq Mm , 3 Core 35 Sq Mm , 3 Core 50 Sq Mm , 3 Core 70 Sq Mm , 3 Core 95 Sq Mm , Copper Conductor 3.5 Core, Xlpe / Pvc Insulated & Armoured Cable . Supplying Xlpe / Pvc Insulated, Armoured Cable 1100 V Grade With Isi Mark 3.5 Core, Solid / Stranded Copper Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Complete In An Approved Manner , 3.5 Core 25 Sq Mm , 3.5 Core 35 Sq Mm , 3.5 Core 50 Sq Mm , 3 .5 Core 70 Sq Mm , 3.5 Core 95 Sq Mm , 3.5 Core 120 Sq Mm , 3 .5 Core150sq Mm , 3.5 Core 185 Sq Mm , 3.5 Core 240Sq Mm , 3.5 Core 300 Sq Mm , 3.5 Core 400 Sq Mm , Copper Conductor 3.5 Core Xlpe/Pvc Unarmoured Supplying Xlpe / Pvc Insulated, Unarmoured Cable 1100 V Grade With Isi Mark 3.5 Core, Solid / Stranded Copper Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Complete In An Approved Manner. , 3.5 Core 25 Sq Mm , 3.5 Core 35 Sq Mm , 3.5 Core 50 Sq Mm , 3.5 Core 70 Sq Mm , 3.5 Core 95 Sq Mm , 3.5 Core 120 Sq Mm , 3.5 Core150sq Mm , 3.5 Core 185 Sq Mm , 3.5 Core 240Sq Mm , 3.5 Core 300 Sq Mm , 3.5 Core 400 Sq Mm , Copper Conductor Three Core, Xlpe / Pvc Insulated & Armoured Cable . Supplying Xlpe / Pvc Insulated, Armoured Cable 1100 V Grade With Isi Mark Three Core, Solid / Stranded Copper Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Complete In An Approved Manner. , 3 Core 1.5 Sq Mm , 3 Core 2.5 Sq Mm , 3 Core 4 Sq Mm , 3 Core 6 Sq Mm , 3 Core 10 Sq Mm , 3 Core 16 Sq Mm , 3 Core 25 Sq Mm , 3 Core 35 Sq Mm , 3 Core 50 Sq Mm , 3 Core 70 Sq Mm , 3 Core 95 Sq Mm , 3 Core 120 Sq Mm , 3 Core 150Sq Mm , 3Core 185 Sq Mm , 3 Core 240 Sq Mm , 3 Core 300 Sq Mm , 3 Core 400 Sq Mm , M 1063 - Foot Valve Supplying C.I. Foot Valve Having Single Leather Flap And Gunmetal Seating. Valve Shall Be Fixed On Suction Side Of Pump As Per Requirement Including Jointing Material And Hardware. , Flanged Type , 50 Mm , 65 Mm , 80 Mm , 100 Mm , 125 Mm , 150 Mm , M 1064 - Air Circuit Breaker Acb Breaking Capacity 50Ka Thermal Magnetic Manual Draw Out Type 3 Pole , 1000A , 1250A , 1600A , 2000A , M 1065 - Starter D.O.L. Starter With Ss Enclosure With 380/415 Volt Coil , 5 To 10 Hp , Supplying Fully Automatic Star Delta Starter To Operate Induction Motor Working On 415V,3Phase,50 Hz With No Volt Coil, Over Load Element, On-Off Push Buttons, With Necessary Materials And Connected To Supply, Etc Complete Starter With Original Sheet Steel Encloser F.A.S.D Starter , 10 Hp , 20 Hp , 25 Hp , 40 Hp , 50 Hp , 75 Hp , 100 Hp , 125 Hp , 150 Hp , 250 Hp , M 1066 - Servo Controlled Automatic Voltage Stabilizer Providing, Erecting Servo Controlled Automatic Voltage Stabiliser Suitable For Out Put Voltage Of 415 Volt ± 1%, 3 Ph, 50 Hz, With Copper Wound Transformer (Air/Oil Cooled) As Mentioned Below. The Stabilizer Shall Function Satisfactorily Even If Incoming Supply Is Unbalanced Between Phases Within Range Of 10%. The Stabilizer Should Be Constructed In Cubical Box, With Bidirectional Wheels For Easy Handling, Necessary Monitors And Users Controls On Front Panel Such As Indication, Alarm, Volt Meter And Selector Switch For Measuring Input And Out Put Voltage, Auto/Manual Selector Switch, Raise/Low Push Buttons Etc. Suitable Capacity Termination Strips And Bus Bars For Incoming And Out Going Cable Should Be Provided. All Three Phases Shall Be Independently Monitored And Corrected. Following Protections And Indications Shall Be Incorporated 􀂌 Over Voltage / Under Voltage 􀂌 Single Phasing 􀂌 Cut Off Contactor With Electronic Output Sensing Unit , Servo Controlled Automatic Voltage Stabiliser(Out Put 415 ± 1%) Input 150 / 220 To 450 / 460 Volt , 30 Kva Air Cooled , 40 Kva Air Cooled , 50 Kva Oil Cooled , 60 Kva Oil Cooled , 75 Kva Oil Cooled , 100 Kva Oil Cooled , 125 Kva Oil Cooled , Servo Controlled Automatic Voltage Stabiliser (Out Put 415 ± 1%) Input 280 To 450/460 Volt , 15 Kva Air Cooled , 20 Kva Air Cooled , 30 Kva Air Cooled , 40 Kva Air Cooled , 50Kva Air Cooled , 60 Kva Oil Cooled , 75Kva Oil Cooled , 100 Kva Oil Cooled , 125 Kva Oil Cooled , 150 Kva Oil Cooled , 200Kva Oil Cooled , M 1067 - Termination Kit Providing And Errecting In-Door Type Termination Kit, For 3.3Kv/ 6.6 Kv / 11Kv/ 22Kv/33Kv Xlpe Screened 3 Core Cable , In-Door Termination Kit For 3.3Kv(E/Ue) / 6.6 Kv(E) Xlpe 3 Core Cable , 25-50 Mm² , 70-120 Mm² , 150-185 Mm² , 240-400 Mm² , Out-Door Termination Kit For 3.3(E/Ue)/6.6 Kv(E) Xlpe 3 Core Cable , 25-50 Mm² , 70-120 Mm² , 150-185 Mm² , 240-400 Mm² , Straight Through Joint For 3.3Kv(E/Ue)/ 6.6 Kv(E) Xlpe 3 Core Cable , 25-50 Mm² , 70-120 Mm² , 150-185 Mm² , 240-300 Mm² , In Door Termination Kit For 11Kv(E) Xlpe Screened 3 Core Cable , 25-50 Mm² , 70-120 Mm² , 150-185 Mm² , 240-400 Mm² , Out Door Termination Kit For 11Kv(E) Xlpe Screened 3 Core Cable , 25-50 Mm² , 70-120 Mm² , 150-185 Mm² , 240-400 Mm² , Straight Through Joint For 11 Kv(E) Xlpe Screened 3 Core Cable , 25-50 Mm² , 70-120 Mm² , 150-185 Mm² , 240-300 Mm² , In Door Termination Kit For 22Kv(E) Xlpe Screened 3 Core Cable , 25-50 Mm² , 70-120 Mm² , 150-185 Mm² , 240-400 Mm² , Out Door Termination Kit For 22Kv(E) Xlpe Screened 3 Core Cable , 25-50 Mm² , 70-120 Mm² , 150-185 Mm² , 240-400 Mm² , Straight Through Joint For 22 Kv(E) Xlpe Screened 3 Core Cable , 25-50 Mm² , 70-95 Mm² , 120-150 Mm² , 185-240 Mm² , 300-400 Mm² , In Door Termination Kit For 33Kv(E) Xlpe Screened 3 Core Cable , 25-50 Mm² , 70-95 Mm² , 120-185 Mm² , 240-400 Mm² , Out Door Termination Kit For 33 Kv(E) Xlpe Screened 3 Core Cable , 25-50 Mm² , 70-95 Mm² , 120-185 Mm² , 240-400 Mm² , Straight Through Joint For 33 Kv(E) Xlpe Screened 3 Core Cable , 35-70 Mm² , 95-150 Mm² , 185-240 Mm² , 240-300 Mm²
Contract Date : Ref. Documents   |   Contract Value : Ref. Documents
BRR : 11348134 Tender for E-Quotation For Seeking Firm Rates Of Plant & Machinery And Materials Category Items For Preperation/Amendment Of Schedule Of Rate For The Year 2026. , M 1055 - Pumps Supplying Submersible Pump Sets Confirming To Is 8034 And Motor Confirming To Is 9283. Pump Shall Be Suitable For Various Delivery Head And Discharge With Stainless Steel Pump Shaft And Polypropylene/ Noryl Impeller. Motor Suitable For Working On 415V+10%, 3Ph, 50 Hz, A.C. Supply With Cable Guard, Thrust Carbon/ Fiber Bearing To Withstand Entire Hydraulic Thrust, Water Proof Winding Shall Be Provided. The Pump Set Shall Be Suitable For Direct Coupling. Pump Shall Have Suitable Outlet As Per Manufacturers Design. Anti Thrust Stream Lined Non Return Valve Shall Be Provided With Pump. 3 Meter Submersible Copper Conductor Cable In Single/ Double Run Shall Be Provided With Each Pump. , Submersible Pump Set 100 Mm Dia (With Polypropylene/ Noryl Impeller) Up To 20 Stages 1 H.P. , 1.5 Hp , 2.5 Hp , 3.0 Hp , 4.0 Hp , 5.0 Hp , Submersible Pump 150 Mm Dia (With Bronze/Ss Impeller) Up To 8 Stages , 1.5 Hp , 2.0 Hp , 3.0 Hp , 4.0 Hp , 5.0 Hp , 6.0 Hp , 7.5 Hp , M 1056 - Pressure Guage Providing Fabricating, Testing And Commisioning Pressure Vessel Fabricating In M.S Plate On Providing Foundation Including Epoxy Paint , Pressure Gauge (100 Mm Dia) , Pressure Gauge (150 Mm Dia) , Vacuum / Combination Gauge , M 1057 - Lifting Equipment Chain Pulley Block Supplying Triple Spur Gear Type Chain Pulley Block Suitable For Capacity As Below With 3 M Lift Complete With Load Chain And Hand Chain Suitable For Above Lift, Tested To 50% Over Load As Per Is 3832 Carrying Isi Mark. , 1 Tonne Capacity , 2 Tonne Capacity , 3 Tonne Capacity , Electric Operated Circular Or Rectangular Travelling Crane (Single Girder) Supplying Single Girder Electrically Operated Rectangular Over Head Travelling Crane With 6 M Lift Complete With Wire Rope Hoist, Class Ii Duty, All Three Motions Electrically Operated By Suitable Rating Motor Ip 54, Control Panel And Down Pendant Control Block. , 5 Tonne Capacity , Above 6 M Up To 8 M Span , Above 8 M Up To 10 M Span , 7.5 Tonne Capacity , Above 6 M Upto 8 M Span , Above 8 M Up To 10 M Span , 10 Tonne Capacity , Above 6 M Up To 8 M Span , Above 8 M Up To 10 M Span , M 1058 - Lightening Arrester, Ab Switch, Insulators , Lightening Arrestor Supplying, Erecting Approved Make Thyrite Type Lightening Arrestor Suitable For H.T. Supply With Necessary Ancillary Material Complete On Provided Cross Arm And Connected To Overhead Line. , Suitable For 11 Kv Supply, Distribution Class , Suitable For 22 Kv Supply, Distribution Class , Suitable For 33 Kv Supply, Station Class , Disc Insulator. Supplying, Erecting Porcelain Disc Type Insulators With Hardware Fittings Suitable For H.T. Overhead Line Complete Erected With Nuts And Bolts On Provided Cross Arm , Suitable For 11Kv Line , Suitable For 33Kv Line , Pin Insulator Supplying, Erecting Porcelain Pin Type Insulators With Hardware Fittings Suitable For H.T. Overhead Line Complete Erected With Nuts And Bolts On Provided Cross Arm , Suitable For 11Kv Line , Suitable For 33Kv Line , Air Break Switch Without Earth Switch Supplying, Erecting Approved Make H.T. Outdoor Type Gang Operated Air Break Triple Pole Switch Of Required Capacity With 3 Post / Pin Type Insulator Per Phase , Mounted In Horizontal Or Vertical Position On Provided Cross Arm With Adequate Length Of G.I. Pipe For Operating Handle Erected On Extended Square Shaft. The Operating Handle Provided With Lock And Key At Suitable Height From Ground With Necessary Clamps , Suitable For 11Kv Line , Rocking / Tilting Type , Rotating Type , Suitable For 33Kv Line , Rocking / Tilting Type , Rotating Type , Air Break Switch With Earth Switch Supplying, Erecting Approved Make H.T. Outdoor Type Gang Operated Air Break Triple Pole Switch With Earth Switch Of Required Capacity With 3 Post / Pin Type Insulator Per Phase , Mounted In Horizontal Or Vertical Position On Provided Cross Arm With Adequate Length Of G.I. Pipe For Operating Handle Erected On Extended Square Shaft. The Operating Handle Provided With Lock And Key At Suitable Height From Ground With Necessary Clamps , Suitable For 11 Kv Line , Rotating Type , Suitable For 33 Kv Line , Rotating Type , Drop Out Fuse (Channel Mounted) Supplying, Erecting Approved Make Out Door Type Drop Out Fuse Channel Type With Insulator Complete With Fuse Holders Fuse Barrel With Metal Fittings, Fuse Element, With Working Current Up To 50 Amp, Capacity Complete Erected On Provided Cross Arm, Each Set Comprising 3 Units , Suitable For 11 Kv Line , Suitable For 33 Kv Line , Horn Gap Fuse (Channel Mounted) Supplying, Erecting Approved Make Out Door Type Horn Gap Type Fuse With Insulator, Fuse Element, With Working Current Up To 50 Amp, Capacity Complete Erected On Provided Cross Arm, Each Set Comprising 3 Units , Suitable For 11 Kv Line , Suitable For 33 Kv Line , M 1059 - Transformer Power Transformer (With Off Load Tap Changer) Any Isi Mark , Supplying Outdoor Type Copper Wound Transformer Continuously Rated For 3Ph, 50 Hz, At Full Load And Temp. Rise Not Exceeding 45 Degree C By Thermometer In Oil And 50 Degree C By The Resistance In Winding After Continuous Run At Full Load Rating, The Transformer Should Have Oil Immersed Winding Having Vector Group Dy11, Ht Side Connected In Delta And Lt Side Connected In Star With Neutral Brought Out Connected To Provide Separate Earthing. The Transformer Shall Have Power Terminal Arrangement, Bushing/ Cable End Box On Ht Side And Cable End Box On Lt Side. 2 Nos Channels With Stoppers Shall Be Provided And Fixed On The Provided Plinth For Mounting The Transformer. The Transformer Should Have Following Standard Fittings. Transformer Shall Be Latest Manufacturing Standards As Per Amended Is Specifications And The Load & No Load Losses Shall Be Limited To The Values Given Below Or As Per Is Or Norms Issed By Seb Which Ever Are Lower- 1. Oil Conservator With Filling Hole With Cap And Plain Oil Level Gauge. 2. Silica Gel Dehydrating Breather Charged With Silica Gel. 3. Oil Drain Valve 4. Oil Filter Valve 5. Lifting Eyes/ Hooks 6. Two Earthing Terminals 7. Diagram And Rating Plate 8. Air Vent 9. Explosion Vent 10. 100Mm Dia Thermo Meter With Thermometer Pocket 11. Four arc-biannual rate contract Directional Plain Roller. , Power Transformer 11000/433 Volts With Off Load Tap Changer - 12.5% To +2.5% In Steps Of 2.5% As Per Bis Level-2. , 63 Kva , 100 Kva , 160 Kva , 200 Kva , 250 Kva , 315 Kva , 500 Kva , 630 Kva , 750/800 Kva , Power Transformer (With On Load Tap Changer) Supplying Outdoor Type Copper Wound Transformer Continuously Rated For 3Ph, 50 Hz, At Full Load And Temp. Rise Not Exceeding 45 Degree C By Thermometer In Oil And 50 Degree C By The Resistance In Winding After Continuous Run At Full Load Rating, The Transformer Should Have Oil Immersed Winding Having Vector Group Dy11, Ht Side Connected In Delta And Lt Side Connected In Star With Neutral Brought Out Connected To Provide Separate Earthing. The Transformer Shall Have Power Terminal Arrangement, Bushing/ Cable End Box On Ht Side And Cable End Box On Lt Side. 2Nos Channels With Stoppers Shall Be Provided And Fixed On The Provided Plinth For Mounting The Transformer. The Transformer Should Have Following Standard Fittings. The Oltc Should Be Suitable For Minimum 50 Operations Per Day. Transformer Shall Be Latest Manufacturing Standards As Per Amended Is Specifications And The Load & No Load Losses Shall Be Limited To The Values Given Below Or As Per Is Or Norms Issued By Seb Which Ever Are Lower- , 1. Oil Conservator With Filling Hole With Cap And Plain Oil Level Gauge. 2. Silica Gel Dehydrating Breather Charged With Silica Gel. 3. Oil Drain Valve 4. Oil Filter Valve 5. Lifting Eyes/ Hooks 6. Two Earthing Terminals 7. Diagram And Rating Plate 8. Air Vent 9. Explosion Vent 10. 100Mm Dia Thermo Meter With Thermometer Pocket 11. Four arc-biannual rate contract Directional Plain Roller. 12. Buchholz Relay 13. Resistance Temp. Detector 14. Marshalling Box 15. Automatic Voltage Regulator (Avr) 16. Remote Tap Changing Controller (Rtcc) , Transformer 11000/433 Volts With On Load Tap Changer - 15% To +5% In Steps Of 1.25% With Rtcc, Avr And Marshalling Box And Other Specification , 750/800 Kva , 1000 Kva , 1250 Kva , 1600 Kva , 2000 Kva , M 1060 - Motors Foot Mounted Motors Tefc 1500 Rpm Supplying Foot Mounted Tefc 1500 Rpm, Squirrel Cage Induction Motor, Conforming To Is 325 Having Continuous Rating Suitable For Operation At 415 Volts ± 10%, 3 Phase, 50 Hz ± 3% With F Class Insulation Temperature Rise Limited To Class B Insulation. Motors Conform To Is-12615 With Efficiency Level Ie3 And Provided With Enclosure Protection Class Ip-55. , 15 Kw (20 Hp) , 18.5 Kw ( 25 Hp) , 22 Kw ( 30 Hp) , 30 Kw ( 40 Hp) , 37 Kw ( 50 Hp) , 45 Kw ( 60 Hp) , 55 Kw ( 75 Hp) , 75 Kw ( 100 Hp) , 90 Kw ( 120 Hp) , 110 Kw ( 150 Hp) , 132 Kw ( 180Hp ) , 160 Kw ( 215 Hp ) , M 1061 - Aluminium Cable Cable - Aluminium Conductor Three Core, Xlpe / Pvc Insulated & Armoured Cable . Supplying Xlpe / Pvc Insulated, Armoured Cable 1100 V Grade With Isi Mark Three Core, Solid / Stranded Aluminium Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Complete In An Approved Manner. , 3 Core 2.5 Sq Mm , 3 Core 4 Sq Mm , 3 Core 6 Sq Mm , 3 Core 10 Sq Mm , 3 Core 16 Sq Mm , 3 Core 25 Sq Mm , 3 Core 35 Sq Mm , 3 Core 50 Sq Mm , 3 Core 70 Sq Mm , 3 Core 95 Sq Mm , 3 Core 120 Sq Mm , 3 Core 150 Sq Mm , 3 Core 185 Sq Mm , 3 Core 240 Sq Mm , 3 Core 300 Sq Mm , 3 Core 400 Sq Mm , Ht Aluminium Three Core 3.3 Kve Cable Xlpe Insulated Supplying Ht Aluminium Three Core Cable Xlpe Insulated ,Insulation Screened With Extruded Semi Conducting Compound In Combination With Copper Tape (0.3 Ka For 1 Sec.) Cores Laidup Inner Sheath Of Pvc Tape ,Galvanised Steel Flat Strip Armoured,And Overall Pvc Sheathed Cable Conforming To Is :7098 /Ii/85 With Latest Amendments , 3 Core 70 Sq Mm , 3 Core 95 Sq Mm , 3 Core 120 Sq Mm , 3 Core150sq Mm , 3 Core 185 Sq Mm , 3 Core 240Sq Mm , 3 Core 300 Sq Mm , 3 Core 400 Sq Mm , M 1062 - Copper Cable Cable , 3 Core Pvc Insulated, Pvc Sheathed Copper Conductor Flat Submersible Cable . Supplying , Flat Flexible Submersible Cable With, Copper Conductor, Pvc Insulated, And Pvc Sheathed . , 3 Core 1.5 Sq Mm , 3 Core 2.5 Sq Mm , 3 Core 4 Sq Mm , 3 Core 6 Sq Mm , 3 Core 10 Sq Mm , 3 Core 16 Sq Mm , 3 Core 25 Sq Mm , 3 Core 35 Sq Mm , Copper Conductor Three Core, Xlpe / Pvc Insulated & Unarmoured Cable Supplying Xlpe / Pvc Insulated, Unarmoured Cable 1100 V Grade With Isi Mark Three Core, Solid / Stranded Copper Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Complete In An Approved Manner. , 3 Core 1.5 Sq Mm , 3 Core 2.5 Sq Mm , 3 Core 4 Sq Mm , 3 Core 6 Sq Mm , 3 Core 10 Sq Mm , 3 Core 16 Sq Mm , 3 Core 25 Sq Mm , 3 Core 35 Sq Mm , 3 Core 50 Sq Mm , 3 Core 70 Sq Mm , 3 Core 95 Sq Mm , Copper Conductor 3.5 Core, Xlpe / Pvc Insulated & Armoured Cable . Supplying Xlpe / Pvc Insulated, Armoured Cable 1100 V Grade With Isi Mark 3.5 Core, Solid / Stranded Copper Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Complete In An Approved Manner , 3.5 Core 25 Sq Mm , 3.5 Core 35 Sq Mm , 3.5 Core 50 Sq Mm , 3 .5 Core 70 Sq Mm , 3.5 Core 95 Sq Mm , 3.5 Core 120 Sq Mm , 3 .5 Core150sq Mm , 3.5 Core 185 Sq Mm , 3.5 Core 240Sq Mm , 3.5 Core 300 Sq Mm , 3.5 Core 400 Sq Mm , Copper Conductor 3.5 Core Xlpe/Pvc Unarmoured Supplying Xlpe / Pvc Insulated, Unarmoured Cable 1100 V Grade With Isi Mark 3.5 Core, Solid / Stranded Copper Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Complete In An Approved Manner. , 3.5 Core 25 Sq Mm , 3.5 Core 35 Sq Mm , 3.5 Core 50 Sq Mm , 3.5 Core 70 Sq Mm , 3.5 Core 95 Sq Mm , 3.5 Core 120 Sq Mm , 3.5 Core150sq Mm , 3.5 Core 185 Sq Mm , 3.5 Core 240Sq Mm , 3.5 Core 300 Sq Mm , 3.5 Core 400 Sq Mm , Copper Conductor Three Core, Xlpe / Pvc Insulated & Armoured Cable . Supplying Xlpe / Pvc Insulated, Armoured Cable 1100 V Grade With Isi Mark Three Core, Solid / Stranded Copper Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Complete In An Approved Manner. , 3 Core 1.5 Sq Mm , 3 Core 2.5 Sq Mm , 3 Core 4 Sq Mm , 3 Core 6 Sq Mm , 3 Core 10 Sq Mm , 3 Core 16 Sq Mm , 3 Core 25 Sq Mm , 3 Core 35 Sq Mm , 3 Core 50 Sq Mm , 3 Core 70 Sq Mm , 3 Core 95 Sq Mm , 3 Core 120 Sq Mm , 3 Core 150Sq Mm , 3Core 185 Sq Mm , 3 Core 240 Sq Mm , 3 Core 300 Sq Mm , 3 Core 400 Sq Mm , M 1063 - Foot Valve Supplying C.I. Foot Valve Having Single Leather Flap And Gunmetal Seating. Valve Shall Be Fixed On Suction Side Of Pump As Per Requirement Including Jointing Material And Hardware. , Flanged Type , 50 Mm , 65 Mm , 80 Mm , 100 Mm , 125 Mm , 150 Mm , M 1064 - Air Circuit Breaker Acb Breaking Capacity 50Ka Thermal Magnetic Manual Draw Out Type 3 Pole , 1000A , 1250A , 1600A , 2000A , M 1065 - Starter D.O.L. Starter With Ss Enclosure With 380/415 Volt Coil , 5 To 10 Hp , Supplying Fully Automatic Star Delta Starter To Operate Induction Motor Working On 415V,3Phase,50 Hz With No Volt Coil, Over Load Element, On-Off Push Buttons, With Necessary Materials And Connected To Supply, Etc Complete Starter With Original Sheet Steel Encloser F.A.S.D Starter , 10 Hp , 20 Hp , 25 Hp , 40 Hp , 50 Hp , 75 Hp , 100 Hp , 125 Hp , 150 Hp , 250 Hp , M 1066 - Servo Controlled Automatic Voltage Stabilizer Providing, Erecting Servo Controlled Automatic Voltage Stabiliser Suitable For Out Put Voltage Of 415 Volt ± 1%, 3 Ph, 50 Hz, With Copper Wound Transformer (Air/Oil Cooled) As Mentioned Below. The Stabilizer Shall Function Satisfactorily Even If Incoming Supply Is Unbalanced Between Phases Within Range Of 10%. The Stabilizer Should Be Constructed In Cubical Box, With Bidirectional Wheels For Easy Handling, Necessary Monitors And Users Controls On Front Panel Such As Indication, Alarm, Volt Meter And Selector Switch For Measuring Input And Out Put Voltage, Auto/Manual Selector Switch, Raise/Low Push Buttons Etc. Suitable Capacity Termination Strips And Bus Bars For Incoming And Out Going Cable Should Be Provided. All Three Phases Shall Be Independently Monitored And Corrected. Following Protections And Indications Shall Be Incorporated 􀂌 Over Voltage / Under Voltage 􀂌 Single Phasing 􀂌 Cut Off Contactor With Electronic Output Sensing Unit , Servo Controlled Automatic Voltage Stabiliser(Out Put 415 ± 1%) Input 150 / 220 To 450 / 460 Volt , 30 Kva Air Cooled , 40 Kva Air Cooled , 50 Kva Oil Cooled , 60 Kva Oil Cooled , 75 Kva Oil Cooled , 100 Kva Oil Cooled , 125 Kva Oil Cooled , Servo Controlled Automatic Voltage Stabiliser (Out Put 415 ± 1%) Input 280 To 450/460 Volt , 15 Kva Air Cooled , 20 Kva Air Cooled , 30 Kva Air Cooled , 40 Kva Air Cooled , 50Kva Air Cooled , 60 Kva Oil Cooled , 75Kva Oil Cooled , 100 Kva Oil Cooled , 125 Kva Oil Cooled , 150 Kva Oil Cooled , 200Kva Oil Cooled , M 1067 - Termination Kit Providing And Errecting In-Door Type Termination Kit, For 3.3Kv/ 6.6 Kv / 11Kv/ 22Kv/33Kv Xlpe Screened 3 Core Cable , In-Door Termination Kit For 3.3Kv(E/Ue) / 6.6 Kv(E) Xlpe 3 Core Cable , 25-50 Mm² , 70-120 Mm² , 150-185 Mm² , 240-400 Mm² , Out-Door Termination Kit For 3.3(E/Ue)/6.6 Kv(E) Xlpe 3 Core Cable , 25-50 Mm² , 70-120 Mm² , 150-185 Mm² , 240-400 Mm² , Straight Through Joint For 3.3Kv(E/Ue)/ 6.6 Kv(E) Xlpe 3 Core Cable , 25-50 Mm² , 70-120 Mm² , 150-185 Mm² , 240-300 Mm² , In Door Termination Kit For 11Kv(E) Xlpe Screened 3 Core Cable , 25-50 Mm² , 70-120 Mm² , 150-185 Mm² , 240-400 Mm² , Out Door Termination Kit For 11Kv(E) Xlpe Screened 3 Core Cable , 25-50 Mm² , 70-120 Mm² , 150-185 Mm² , 240-400 Mm² , Straight Through Joint For 11 Kv(E) Xlpe Screened 3 Core Cable , 25-50 Mm² , 70-120 Mm² , 150-185 Mm² , 240-300 Mm² , In Door Termination Kit For 22Kv(E) Xlpe Screened 3 Core Cable , 25-50 Mm² , 70-120 Mm² , 150-185 Mm² , 240-400 Mm² , Out Door Termination Kit For 22Kv(E) Xlpe Screened 3 Core Cable , 25-50 Mm² , 70-120 Mm² , 150-185 Mm² , 240-400 Mm² , Straight Through Joint For 22 Kv(E) Xlpe Screened 3 Core Cable , 25-50 Mm² , 70-95 Mm² , 120-150 Mm² , 185-240 Mm² , 300-400 Mm² , In Door Termination Kit For 33Kv(E) Xlpe Screened 3 Core Cable , 25-50 Mm² , 70-95 Mm² , 120-185 Mm² , 240-400 Mm² , Out Door Termination Kit For 33 Kv(E) Xlpe Screened 3 Core Cable , 25-50 Mm² , 70-95 Mm² , 120-185 Mm² , 240-400 Mm² , Straight Through Joint For 33 Kv(E) Xlpe Screened 3 Core Cable , 35-70 Mm² , 95-150 Mm² , 185-240 Mm² , 240-300 Mm²
Contract Date : Ref. Documents   |   Contract Value : Ref. Documents
BRR : 10148185 K2 Agreement Running Works Contract for Erection, Maintenance and Dismantling of Electrical Networks including Capital and Improvement, DCW worksand Maintenance of 110 KV, 33 KV Sub Stations ( OH lines and UG Cables includingSub-Station Maintenance ) AEE / O&M / Oragadam Sub-Division in Sriperumbudur Division in Kanchipuram EDC for a period of ONE YEAR Under E- Open Tender system. ; 1 Excavation of Pole pit of size 2x2x1/6 of the height of thepole upto 8 mtr pole by using JCBor Manual 2 Excavation of Pole pit of size 2x2x1/6 of the height of the pole above 8mtr by using JCBor Manual 3 Excavation of pit in Hard soil (common to all size of poles) 4 Excavation of pit in Rocky area (common to all size of poles) by blasting /Manual 5 Excavation of Staypit2x2x5depthby using JCB or manual 6 Excavation of Staypit2x2x5depthin hard rock soil 7 Erection of RCCpoles/PSC poles/Metalpoles up to8.00 M (27 ) by using JCB or manual 8 Erection of RCCpoles/PSC poles/Metalpolesabove 8.00 M by using JCB or maual 9 Erection of metal supports above 9m/RSJ/Rail pole/Tubular poles 10 Erectionofstaysetcomplete with fixing up stay wire EYE, bow, Guy shackle, Binding etc., 11 Erectionofadditional stay in the same rod, excluding excavation of stay pit and burial of stay rod 12 Erectionofstay set complete in the rock area by blasting 13 Fixing of HTV crossarms(all types) / channelcrossarms/guardingCrossarms 14 Fixing of LT 3 phasecrossarms 15 Fixing of LT Single phase cross arms 16 Fixing of HT/LTTIFittings 17 FixingofHTpinInsulators 11 KV/ 22 KV/ 33 KV 18 FixingofHT11 KVstraindisc. 19 FixingofHT22 KV/33 KVstraindisc. 20 FixingofLTpinInsulator 21 FixingofLTshackle 22 FixingofAluminium Knob 23 Earthing of pole with pin including looping binding and burying 24 EarthingofadditionalCrossarm 25 Fixingoftopchannel 10 centre/15 centre 26 Fixing of bed channel 27 Fixing of centre support for bed channel 28 Fixing of belting angle 29 Erection of 11 KV AB Switch 30 Erection of 11 KV Vertical type AB Switch for single pole DT 31 Erection of 11 KV HG Fuse set 32 Erection of 11 KV Solid core HG Fuse set 33 Feeder arrangements with open type fuse units 34 Fixing of HT LAS 35 Fixing of LT LAS 36 HT Jumpering complete for Transformer DT Structure 37 HT Jumpering complete for DP Structure 38 Fixingofcrossbracing(4 nos angles) 10 Centre/15 centre 39 Fixing of danger board 40 Erection of Transformer centre set arrangments 41 FixingofDistributionTransformerName Board (Nameofthe22/11KV #, Name of theSS and Capacity) including Supply of board (1 x 1.5 x 3 mm thickness) including the cost of paint and labour charges 42 Fixing of LT Cable arrangements while erectingsingle pole DT 43 Fixing of Earth coller for earth pits 44 Erection of Aluminium bus bar pipe complete for HT bus bar arrangements for DP structure 45 Erection of Aluminium bus bar pipe complete for HT bus bar arrangements for Triple pole and four pole structure 46 Fixing of 2 Tapping cross arm per cut point upto 33 KV line including fixing of discs insulators and jumpering etc., 47 Fixing of support insulator angle and erection of 3 nos Pin insulator 48 Fixing of MCD box 49 Paving and stringing of conductors of sizes upto 7/2.59 mm ACSR or other equivalent conductor 50 Paving and stringing of conductors ofsizes upto 7/3.35mm ACSR or other equivalent conductor 51 Paving and stringing of conductors of7/4.09mm ACSR or other equivalent conductor 52 Paving and stringing of conductors of7/4.72 mm Dog Conductor or other equivalent conductor 53 Releasing and reerection (resagging) of one run of conductors of sizes upto 7/2.59 mm ACSR or other equivalent conductor 54 Releasing and reerection (resagging) of one run of conductors of sizes upto 7/3.35 mm ACSR or other equivalent conductor 55 Releasing and reerection (resagging) of one run of conductors of size7/4.09 mm ACSR or other equivalent conductor 56 Releasing and reerection (resagging) of one run of conductors of size7/4.72 mm ACSR DOG or other equivalent conductor 57 Numbering of pole by using Enamel paint including cost of paint and painting charges (Numbering in black letters with yellow base by using stencils/skilled painters. The height of lettering shall be 40 mm for numbers and 50 mm for alphabets) 58 Painting of Cement Poles by Distemper coating including cost of distemper 59 Painting of iron Poles upto 36 ft length with double coats including cost of paint 60 Painting of iron Poles upto 40 ft 200/100 length with double coats including cost of paint 61 Paintingoftopchannel 62 PaintingofABswitch 63 Paintingcross Bracing(4 Nos. Angles) both 10 & 15 centre 64 PaintingofDistribution Transformer of all capacities (paint supplied by the Board) including clening of DT 65 PaintingofHGfuse. 66 PaintingofHTmeteringsetand Box 67 Painting of structure materials distribution transformer with aluminium paint of structure poles and writing of transformer details (Items 1 to 6 brush to be owned by the contractor) (Paint to be supplied by Board) 68 Painting of poles and all other metal parts while erecting D.P. Structure 69 Painting of pole and all other metal parts while erecting new single pole distribution transformer Structure 70 Service connection details painting 71 Structure Concreting ,Concreting of poles with size (2x2x5) including cost of Cement ,20 mm jelly and Sandwith a mixture of 1:2:4and plastering of concrete with ratio 1:2 72 Sleeveconcreting with size (2x2x3) including cost of excavation Cement ,40 mm jelly and Sandwith a mixture of 1:3:6and plastering of concrete with ratio 1:2 including materials 73 Stay concreting of Stay with Size 1.5 X 1.5 X 3.0 including cost of Cement, 40mm Jelly and sand (with supply) with mixture 1:3:6 along sleeve concreting and plastering of concrete portion above the ground level with ratio 1:2. 74 Erection of DP structure with stay as per TNEB Standard including fixing of top channel, cross bracing concreting, painting, colour washing etc., With 11 KV/22 KV/33 KV AB switch using all types of poles of size 9.14m and above length 75 Erection ofDouble Pole Transformer Structure complete as per TNEB standard including painting, feeders arrangement, colour washing of RCC poles etc., Fixing of poles type to be unit HT/LT LAS and jumpering 3 nos earth pits with earth trough except erection of DT 76 (i) Erection of 11 KV Single pole Transformer Structure including erection of DT complete with centre support 77 (ii) Erection of 11 KV Single pole Transformer Structure including erection of DT complete without centre support 78 (iii) Erection of 11 KV Single pole DP structure with stay as per TNEB Standard including fixing of top channel, cross bracing concreting, painting, colour washing etc., with single earth 79 Erection of Distribution Transformer including loading of Distribution Transformer at stores and erection at structure or Upto 100 KVA Distribution transformer / Metering set. 80 Erection of Distribution Transformer including loading of Distribution Transformer at stores and erection at structure Above 100 KVA to 250 KVA 81 Erection of Distribution Transformer including loading of Distribution Transformer at stores and erection at structure 500 KVA and above 82 Failed DT replacement below 100 KVA & 100 KVA and above 83 LTsplitneutralguarding 84 Flatguardingincludingfixingof2 Nos. crossarms HTLT 85 D.O.T. Crossing 86 RailwayCrossing ( cradle guarding). 87 Earthing of poles with GI wires 4 or 6 SWG by coil earthing 88 Provision of spike including earthing arrangement 89 Pipe earthing including excavation of earth pit and fixing earth pipe 3m length 90 Replacing the corroded earth pipes of transformer structure and replacing the earth wire completely with aluminium lugs for termination 91 Replacement of corroded earth pipe 92 EarthingofD.P.complete 93 Earthing of new single pole distribution transformer structure complete 94 Loading or unloading of Distribution Transformer Upto 100 KVA 95 Loading or unloading of Distribution Transformer above 100 KVA and upto 500 KVA 96 Loading or unloading of Metering set of all ratios 97 Loading or unloading of various sizes of poles REC, RCC, PSC pole upto 8.00 m length 98 Loading or unloading of various sizes of poles All REC, RCC pole above 8.00 m length 99 Loading or unloading of various sizes of poles Metal poles all sizes 100 Loading of Conductor 101 Unloading of Conductor 102 Loading / Unloading of Iron & Steel 103 Loading / Unloading of Oil 104 Loading / Unloading of line materials 105 Loading / Unloading of 11 KV strain disc 106 Loading / Unloading of LT Pin insulator shackle, guy shackle, LT Pin, Metal parts, HT pin etc., 107 Loading / Unloading of single phase meters 108 Loading / Unloading of three phase meters 109 Loading and unloading of cementbagof50Kg. 110 Loading and Stacking of Materials 111 Transportation of all types and sizes of poles and other associated materials from Road side to pole pit and vice versa upto 0.50 KM 112 Transportation of all type of poles by bullock cart or other vehicle (for all sizes of poles including loading and unloading) For a lead upto 5 KM 113 Transportation of all type of poles by bullock cart or other vehicle (for all sizes of poles including loading and unloading) For a lead Above 5 KM of lead of every KM 114 Transport of Metal pole of all sizes by head loads in hill areas from road side to pole pit location Upto 1 KM 115 Transport of Metal pole of all sizes by head loads in hill areas from road side to pole pit location Above 1 KM per each KM 116 Transporting of conductors of all sizes from road side to pit locations upto one KM of Conductor 117 (i) Transporting of Distribution Transformer / Line materials from stores to office / site upto 10 KM distance by engaging 1 Ton capacity Minidor (Lorry) 118 (i) Transporting of Distribution Transformer / Line materials from stores to office / site ABOVE 10 KM distance by engaging 1 Ton capacity Minidor (Lorry) 119 Erectionofstreetlightservice including fixure fitting 120 Erectionofstreetlightservice 121 FixingofnewSV/MV/LEDlampfittings 122 AssistingforsurveyofHT/LT 123 Hutservicefixing 124 Agriculturalservicefixing / service 125 Breaking and ReleasingofgrillsfromRCCPSC poles 126 Releasingofsingle phaseservicewire and re-fixing. 127 Releasingof3 phaseservice wire and(upto 50 HP)re-fixing. 128 Releasingof3 phaseservice wireand(above 50 HP)re-fixing. 129 Labourchargesforalterationof Back clamps tosuitfortheworks 130 Labourchargesforalterationof Stay clamps tosuitfortheworks 131 ProvidingLTbusbararrangementin distn. Trs. Structurelocation 132 FixingofmeteronLVsideofDT 133 Erectionofconcreteearthtubto DistributionTransformerearthpipe 134 Dismantlingofdetoriatedcables/Replacementof varioussize(95,120,185 Sq.mm) from Distribution TransformerLTbushingtoLT opentypeclampandprovisionof suitable lugsatboththeends. 135 DismantlingandErectionofLTopen typefuseunitAluminium clamps 136 DismantlingofDistn. Transformerfrom structure TransportingtospecialMaintenance assistingthespecialmaintenance crewinoverhaulingandreerectionatthe structure up to 8Kms 137 DismantlingofDistn. Transformerfrom structure TransportingtospecialMaintenance assistingthespecialmaintenance crewinoverhaulingandreerectionatthe structure above 8 Kms per km 138 ReleasingofACSR/AAACconductors fromconductordrumandcoiling ACSR 7/3.35, 7/2.59, AAAC7/2.50, 7/3.15 MM (Per/Km.) 139 Tidingofserviceconnectionwitherection ofclampjumperinLow tensionsingle phase SC/line,Aerial Board, Fuse unit and looping. 140 Tidingofserviceconnectionwitherection ofclamp jumperinLowtension three phase line, Aerial Board, Fuse unit and looping. 141 Renewalofjumperfrom22/11 KVline toAB switchtoHG Fuse, HG Fuse to Distn. TransformerwithPG clamps. 142 Cutting of coconut leaves /tree branches 143 Drilling of hole in channel only 3/4 & 1 per hole 144 Cutting of flat 145 Cutting of channel 146 Cutting of Angle 147 Cutting of pipe 148 RSJ polecutting 149 RSJ polewelding 150 Providing of line spacers for single phase line 151 Providing of line spacers for three phase line 152 Hiring Charges for JCB 153 Clearing ofJungle 154 Clearing of scrup in Yard (DT/SS) 155 Set right of all sizes of leaning of poles 156 Erection of LT Shunt Capacitor 157 Ground patrolling of HT lines during Breakdown 158 Rectification of snapped HT line during Break down 159 Rectification of snapped LT line during Break down 160 Erection of Single phase meters 161 Erection of Three phase meters 162 Monthly Maintenance of Distribution TransformerMaintaining Transformer yard and earth pits neat and tidy, Cleaning the entire transformer including the bushings,Checking the earth connections and watering the earth pits,Checking the oil leaks and reporting if any noticed,Reconditioning the breather (by reactivating Silicagel or replacing it if necessary), Checking the LT fuses and renewing them if necessary. 163 Quarterly Maintenance - Renewing the HG fuses 164 Quarterly Maintenance - Measuring the insulation resistance and Load currents 165 Annual Maintenance of Distribution TransformerLubricating the AB switches and checking their operation, Checking the lines and earth connections of AB switch, Checking the lines and earth connections of HT and LT lightning arresters, Checking the HV and LV bushing connections 166 SS Maintenance - Complete maintenance of Power Transformer of all capacities 167 SS Maintenance - Complete maintenance ofBreaker,CT/PT for 110 KV and above 168 SS Maintenance - Complete maintenance of Breaker,CT/PT for capacity less than 110 KV 169 SS Maintenance - Complete maintenance of Centre Rotating Switch 110 KV and above 170 SS Maintenance - Complete maintenance of Centre Rotating Switch below 110 KV 171 SS Maintenance - Replacement of Clamps of all sizes 172 SS Maintenance - Complete maintenance of LAS 110 KV and above 173 SS Maintenance - Complete maintenance of LAS below 110 KV 174 SS Maintenance - Replacement of Jumpers less than 1 metre 175 SS Maintenance - Replacement of Jumpers more than 1 metre 176 SS Maintenance - Maintenance of earth pits and watering 177 SS Maintenance - Cleaning of control and relay panels (Front,Back and inside) 178 SS Maintenance - Mainenance of Capacitor Bank cell 179 SS Maintenance - Replacement of capacitor bank cell 180 SS Maintenance - Replacement of PT Insulator 181 SS Maintenance - Replacement of Female/Male contact for 110 KV 182 SS Maintenance - Replacement of Female/Male contact for less than 110 KV 183 SS Maintenance - Maintenance of Battery 184 Dismantling of RCC, REC, PSC & metal poles upto 8 mt including the closing of the pit 185 Dismantling of RCC, REC, PSC & metal pole above 8 mt including the closing of the pit 186 For breaking the mass concrete of all supports 187 Dismantling of stay set complete including stay rod 188 Dismantling of stay set complete Without stay rod 189 Dismantling of conductors of sizes upto 7/2.59 mm ACSR or other equivalent conductor 190 Dismantling of conductor ofupto 7/3.35 including transporting the conductors to the nearest road side and stocking in coils 191 Dismantling of conductors of7/4.09mm ACSR or other equivalent conductor 192 Dismantling of conductors of7/4.72 mm Dog Conductor or other equivalent conductor 193 Dismantling of Transformer structure materials complete set and transporting the same from the location to the road side 194 Dismantling of V-Cross arm / Channel Cross Arm / Guarding cross Arm 195 Dismantling of 3 Phase Cross arm 196 Dismantling of Single Phase Cross arm 197 Dismantling of HT/LT Fitting 198 Dismantling of 11KV / 22KV / 33KV Pin insulator & 11KVStrain Disc 199 Dismantling of 22KV / 33KV Strain disc 200 Dismantling of LT Pin insulator 201 Dismantling of LT Shackle with hardware 202 Dismantling of Aluminium Knob 203 Loading and unloading of HT Cable including coiling and recoiling 204 Transport of 11 KV HT cable from departmental stores to work spot by engaging private vehicle upto 5 km 205 Transport of 11 KV HT cable from departmental stores to work spot by engaging private vehicle above 5 km 206 Excavation of cable trench 0.6 meters width and 1.2 meters depth including cost of providing sign boards, danger lights indication arrangements wherever necessary all lead,lift, labour and tools and plants etc., complete. Normal Road (earth) 207 Excavation of cable trench 0.6 meters width and 1.2 meters depth including cost of providing sign boards, danger lights indication arrangements wherever necessary all lead,lift, labour and tools and plants etc., complete. Tar road 208 Excavation of cable trench 0.6 meters width and 1.2 meters depth including cost of providing sign boards, danger lights indication arrangements wherever necessary all lead,lift, labour and tools and plants etc., complete. Concrete road 209 Laying of 11 KV 3X300 sq mm XLPE cable 210 Laying of 11 KV 3X120 sq mm XLPE cable 211 Covering HT cable by cement V trough after covering the cable with good loose earth including loading, unloading and transport from stores to site and letter painting of feeding details & Cable size onthe trough 212 Refilling with excavated earth layers well consolidated as per std specification including all materials, lead, lift etc., complete. 213 Transport back any balance cable, empty drums and other materials if any by engaging private vehicle including recoiling, coiling and loading and unloading at both sides from workspot to departmental stores (minimum 2 drums) upto 5 km 214 Transport back any balance cable, empty drums and other materials if any by engaging private vehicle including recoiling, coiling and loading and unloading at both sides from workspot to departmental stores (minimum 2 drums) above 5 km 215 Loading and unloading of LT Cable including coiling and recoiling 216 Transport of LT cable from departmental stores to work spot by engaging private vehicle upto 5 km 217 Transport of LT cable from departmental stores to work spot by engaging private vehicle above 5 km 218 Excavation of cable trench 45 cm width and 75 cm depth including cost of providing sign boards, danger lights, indication arrangements wherever necessary, lead, lift, labour and tools and plants etc., complete.Normal Road (earth) 219 Excavation of cable trench 45 cm width and 75 cm depth including cost of providing sign boards, danger lights, indication arrangements wherever necessary, lead, lift, labour and tools and plants etc., complete.Tar road 220 Excavation of cable trench 45 cm width and 75 cm depth including cost of providing sign boards, danger lights, indication arrangements wherever necessary, lead, lift, labour and tools and plants etc., complete.Concrete road 221 Laying of 4 X 240 sq.mm cable 222 Laying of 4 X 120 sq.mm XPLE cable 223 Laying of 4 X 25 sq.mm cable 224 Laying of 2 X 16 sq.mm cable 225 Refilling with excavated earth layers well consolidated as per std specification including all materials, lead, lift etc., complete. 226 Laying of HT UG Cable using Trenchless technique without pipes 227 Erection of pillar box including excavation of foundation pits as per standard specification 2 Nos pillar concrete walls, coping and earthing the pillars below ground level 1 feet and above 2 feet/3 feetfrom ground level including cost of all materials, cost of labours including electrical works, transportion, lead, lift complete etc.,Mini pillar boxes for 3 feet 228 Erection of pillar box including excavation of foundation pits as per standard specification 2 Nos pillar concrete walls, coping and earthing the pillars below ground level 1 feet and above 2 feet/3 feetfrom ground level including cost of all materials, cost of labours including electrical works, transportion, lead, lift complete etc.,4/6/8 way pillar box 3 feet 229 Erection of pillar box including excavation of foundation pits as per standard specification 2 Nos pillar concrete walls, coping and earthing the pillars below ground level 1 feet and above 2 feet/3 feetfrom ground level including cost of all materials, cost of labours including electrical works, transportion, lead, lift complete etc., 4/6/8 way pillar box 4 feet 230 Cleaning, painting with Aluminium paint 2 coats & numbering pillar box with feeder details.(Estimate sanction, mandatory) including cost of all materials. 8 way pillar box 231 Cleaning, painting with Aluminium paint 2 coats & numbering pillar box with feeder details.(Estimate sanction, mandatory) including cost of all materials.6 way pillar box 232 Cleaning, painting with Aluminium paint 2 coats & numbering pillar box with feeder details.(Estimate sanction, mandatory) including cost of all materials.4 way pillar box 233 Cleaning, painting with Aluminium paint 2 coats & numbering pillar box with feeder details.(Estimate sanction, mandatory) including cost of all materials.Mini way pillar box 234 Cleaning, painting with Aluminium paint 2 coats & numbering pillar box with feeder details.(Estimate sanction, mandatory) without materials. 8 way pillar box 235 Cleaning, painting with Aluminium paint 2 coats & numbering pillar box with feeder details.(Estimate sanction, mandatory) without materials. 6 way pillar box 236 Cleaning, painting with Aluminium paint 2 coats & numbering pillar box with feeder details.(Estimate sanction, mandatory) without materials.4 way pillar box 237 Cleaning, painting with Aluminium paint 2 coats & numbering pillar box with feeder details.(Estimate sanction, mandatory) without materials. Mini way pillar box 238 Dismantling of old 5/6/8 way pillar box including associated accessories, loading on the vehicle, transporting, unloading at stores and stacking. 239 Dismantling of old mini pillar box including associated accessories, loading on the vehicle, transporting, unloading at stores and stacking. 240 Maintenance of pillars works such as replacement of damaged insulators worn out stembolts, lugs, termination of cables and dressing. 8 way pillar box 241 Maintenance of pillars works such as replacement of damaged insulators worn out stembolts, lugs, termination of cables and dressing. 6 way pillar box 242 Maintenance of pillars works such as replacement of damaged insulators worn out stembolts, lugs, termination of cables and dressing. 4 way pillar box 243 Maintenance of pillars works such as replacement of damaged insulators worn out stembolts, lugs, termination of cables and dressing. Mini pillar box 244 Earthing of Pillar boxes 8/6/4 and mini pillar boxes 245 Earth Work Exacavation to the (Cable Route) required depth, width Normal 246 Earth Work Exacavation to the (Cable Route) required depth, width Tar 247 Earth Work Exacavation to the (Cable Route) required depth, width Concrete 248 [LT Cable fault rectification works] Laying of 4 X 240 sq.mm cable 249 [LT Cable fault rectification works] Laying of 4 X 120 sq.mm XPLE cable 250 [LT Cable fault rectification works] Laying of 4 X 25 sq.mm cable 251 [LT Cable fault rectification works] Laying of 2 X 16 sq.mm cable 252 Refilling the trench cable 253 Transport of all materials to attending the fault from office to site and site to office vice versa 254 Provision of joint 240/120 Sq mm 255 Provision of joint 25/16 Sq mm 256 Earth work Excavation to the required depth, width(cable route)is 1.2m x 0.6m respectively(As per prevailingPWLC Rates)Normal 257 Earth work Excavation to the required depth, width(cable route)is 1.2m x 0.6m respectively(As per prevailingPWLC Rates)Tar 258 Earth work Excavation to the required depth, width(cable route)is 1.2m x 0.6m respectively(As per prevailingPWLC Rates)Concrete 259 Laying of HT Cable /M (As per prevailing PWLC Rate)11 KV 260 Laying of HT Cable /M (As per prevailing PWLC Rate)33 KV 1 X 630 sqmm 261 Laying of HT Cable /M (As per prevailing PWLC Rate) 33 KV 3 X 630 sqmm & 3X 400 sqmm 262 Installation of terminations by employing private jointer in the absence of company jointer (intimation to be given to company through mail/company phone Nos and record to be maintained)11 KV 120/300 sqmm Indoor/Outdoor terminations 263 Installation of terminations by employing private jointer in the absence of company jointer (intimation to be given to company through mail/company phone Nos and record to be maintained)33 KV 1x630 sqmm Indoor/Outdoor terminations 264 Installation of terminations by employing private jointer in the absence of company jointer (intimation to be given to company through mail/company phone Nos and record to be maintained) 33 KV 3x400/3x630 sqmm Indoor/Outdoor terminations 265 Installation of joint by employing private jointer in the absence of company jointer (intimation to be given to company through mail/company phone Nos and record to be maintained) LT 266 Installation of joint by employing private jointer in the absence of company jointer (intimation to be given to company through mail/company phone Nos and record to be maintained) 11 KV 267 Installation of joint by employing private jointer in the absence of company jointer (intimation to be given to company through mail/company phone Nos and record to be maintained) 33 KV(1X630Sqmm) 268 Installation of joint by employing private jointer in the absence of company jointer (intimation to be given to company through mail/company phone Nos and record to be maintained)33 KV(3x400Sqmm) 269 Refilling with M- sand over the cable and joints cost ofM- sand PWD Schedule of Rate) 11 KV 270 Refilling with M- sand over the cable and joints cost ofM- sand PWD Schedule of Rate) 33 KV 271 Refilling labour charges /mtr (As per PWLC Rate) 11 KV 272 Refilling labour charges /mtr (As per PWLC Rate) 33 KV 273 Transporting of cables and joint kits from stores to site (whichever is applicable)11 KV 274 Transporting of cables and joint kits from stores to site (whichever is applicable)33 KV 275 Transporting of cables and joint kits from office to site (whichever is applicable)11 KV 276 Transporting of cables and joint kits from office to site (whichever is applicable) 33 KV 277 Engaging JCB For Excavation of Earth and Back filling the earth after rectification of fault11 kv 278 Engaging JCB For Excavation of Earth and Back filling the earth after rectification of fault 33 kv 279 Engaging Hydraulic compressor (Tractor) for Breaking concrete/Tar Roads (Wherever Necessary) 11 kv 280 Engaging Hydraulic compressor (Tractor) for Breaking concrete/Tar Roads (Wherever Necessary) 33 kv 281 Rental for de-watering pump as per PWD schedule of Rate (Wherever necessary) 11 kv 282 Rental for de-watering pump as per PWD schedule of Rate (Wherever necessary) 33 kv 283 Engaging Labour for Manual excavation and cleaning the trench, joint pit excavation and identify the cable in addition to engaging JCB 11 kv (Rs.562/-x 2 person) 284 Engaging Labour for Manual excavation and cleaning the trench, joint pit excavation and identify the cable in addition to engaging JCB 33 kv (Rs.562/-x 3 person) 285 Concreting after rectification of fault by using PCC 1:3:6 ( If applicable, with necessary justification & certification by concern Executive Engineer For reqd length,width and depth as per site condition) 11 KV/33 KV 286 Releasing the service connection cable from OH line, cutting the service cable of required length for terminating in the newly erected pillar boxesand handing over of released cable in section storesduring OH line to UG cable conversion works / LTUG 2x16 sqmm cable 287 Releasing the service connection cable from OH line, cutting the service cable of required length for terminating in the newly erected pillar boxesand handing over of released cable in section storesduring OH line to UG cable conversion works/LTUG 4x25 sqmm cable 288 Releasing the service connection cable from OH line, cutting the service cable of required length for terminating in the newly erected pillar boxesand handing over of released cable in section storesduring OH line to UG cable conversion works/LTUG 4x120 sqmm cable
Contract Date : Ref. Documents   |   Contract Value : Ref. Documents
Disclaimer

We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.

Tender Detail
Website https://tender.nprocure.com/
Quantity
MSME Exemption No
Tender Type Open Tender
Startup Exemption Click Here
Competitive Bidding NCB
Similar Tenders
TENDER INSIGHTS

858

Electric Tenders
Live
CLICK TO KNOW MAXIMUM WIN

Tell us about your Product / Services,

We will Find Tenders for you

🇮🇳 +91
TenderDetail
Loading tenders