TDR : 56488651
Central Public Works Department

Tender Brief :

Ghaziabad, Uttar Pradesh

RMO Various E&M Services At EPFO, Sector-24, Noida (UP) (SH- AMC Of Kirloskar Make 1X125 KVA DG Sets, 1X52 HP Fire Diesel Engine)

Published: 15 Jul 2026
Opening: 18 Jul 2026
Closing: 18 Jul 2026
Amount: 1.56 Lakhs
EMD: 3125
Tender Fee: Ref. Documents


Works Accounting Services Acoustical Work Active Harmonic Filter Actuator Advertising Agency
0
Days Left
Tender Summary / Eligibility Criteria
RMO Various E&M Services At EPFO, Sector-24, Noida (UP) (SH- AMC Of Kirloskar Make 1X125 KVA DG Sets, 1X52 HP Fire Diesel Engine)
Documents Download All
9e7e33db-9aa1-47fd-baa9-042e955d6f91
9e7e33db-9aa1-47fd-baa9-042e955d6f91.html
DocumentsList
DocumentsList.zip
No Boq
No Corrigendum
Probable Bidders

AI engine predicts probable bidders to help you bid strategically.

MSME Exception
Explore More →
Technical
Tender involves procurement of high capacity electrical equipment including diaphragm coupling of pump & motor with 90kW capacity at 2900 RPM. The project scope includes installation, testing, commissioning and operational handover.
Previous / Similar Result
BRR : 1645095 Job Contract For Operation And Maintenance Of E And M Installations And Various Capacity Of Dg Sets At Katihar Acs For The Year 2020-21 , Providing Maintenance Services Of Electrical & Mechanical Installations Viz 11 Kv Power Supply System Of Substation / Power House , Transformers , 11 Kv Vcbs , Avrs & Lt Panels , Fire Alarm System , Dg Sets . Covering The Scope Of Operation , Repairs & Maintenance , Attending Faults / Breakdowns Rectifications , Ensuring Serviceability / Satifactory Working Condition Of The Systems , Preventive Maintenance On Daily / Weekly / Monthly / Quarterly / Halfyearly / Yearly Basis , Maintenance Of Records / Documentation Etc . As Per Scope Of Work Given In Special Conditions Of Contract Shall Be Ensured Round The Clock By The Aduquate Manpower ( Ie . In Three Shifts Basis , Each Shift Of 8 Hours ) On All Days Including Sundays & Holidays At Mssr And Dvor Site At Katihar & As Per Direction Of Eic . , Annual Maintenance Contract Of Following Make Dg Sets ( Engine+Panel ) Including Amf Panel With Other Accessories From Oem / Authorised Service Agencies . Job Includes Monthly Visit For Carrying Out Preventive Maintenance & Attending Any Number Of Breakdown Calls As & When Required , Minor Repairs Etc . As Per ManufacturerS Recomondations / Standard Practice And As Per The Scope Of Work , Complete As Required . , 25 Kva Soundproof Kirloskar Green Dg Set- 03 Nos . ( One At Mssr & Two Nos . At Dvor ) . , 160Kva Dg Set { Engine- Cummins Model No 6Bta5 . 9 G5 , Alternator -Stampford } At Mssr Katihar . -01 No . , 250 Kva Dg Set { Engine-Cummins Model No 6Cta8 . 3 G4 , Alternator - Crompton } At Mssr Katihar . - 01 No . , Supply Of B-Checks Kit & Carried Out Of B-Check Of Following Dg Sets As Given Specification & Terms & Condition Etc As Required . , 25 Kva Soundproof Kirloskar Green Dg Set- 03 Nos . ( One At Mssr & Two Nos . At Dvor ) . B Check Kit Consist Of Following Materials As Per Under Given Below . ( I ) Air Filter-01 ( Ii ) Fuel Filter-01 ( Iii ) Diesel Filter-01 ( Iv ) Lube Oil- 7 . 5 Ltr ( V ) Coolent-01 . , 160Kva Dg Set { Engine- Cummins Model No 6Bta 5 . 9G5 , Alternator -Stampford } At Mssr Katihar . ( I ) Air Filter-01 ( Ii ) Fuel Filter-01 ( Iii ) Diesel Filter-01 ( Iv ) Lube Oil- 40 . 0 Ltr ( V ) Coolent-01 . , 250 Kva Dg Set { Engine-Cummins Model No 6Cta8 . 3G4 , Alternator - Crompton } At Mssr Katihar . ( I ) Air Filter-01 ( Ii ) Fuel Filter-01 ( Iii ) Diesel Filter-01 ( Iv ) Lube Oil- 40 . 0 Ltr ( V ) Coolent-01 . , Supply Of 12Volts 150 Ah Lead Maintenance Free Battery Make - Exide Ep150 Or Equivalent . , Providing Maintenance Services Of Fire Alarm Systems Installed At Mssr & Auto Dialer At Dvor , Attending Faults / Breakdowns Rectifications , Ensuring Serviceability / Satifactory Working Condition Of The Systems , Preventive Maintenance As Per Oem , Maintenance Of Records / Documentation Etc . As Per Scope Of Work Given In Special Conditions Of Contract As Per Direction Of Eic . ( Note:- Materials Shall Be Provided By Aai ) .
Contract Date : 02 Jul, 2020   |   Contract Value : 24.44 Lakhs
BRR : 6822020 Annual Rates Contract For Material Purchase Under Jmc For City Water Supply Annual Rates Contract For Material Purchase Under Jmc For City Water Supply , Items : , Main Switch Tpnmake Ssk-16 Amp , Main Switch Tpnmake Ssk-32 Amp , Main Switch Tpnmake Ssk-63 Amp , Main Switch Tpnmake Ssk-100 Amp , Main Switch Tpnmake Ssk-200 Amp , Main Switch Tpn Make Ssk-400 Amp , Automatic Push Button Starter Pannel L&T -3 Hp To 7.5 Hp , Automatic Push Button Starter Pannel L&T-10 Hp , Automatic Push Button Starter Pannel L&T-15 Hp , Automatic Push Button Starter Pannel L&T-20 Hp , Automatic Push Button Starter Pannel Cutler Hammer 3Hp To 7.5Hp , Automatic Push Button Starter Pannel Cutler Hammer 10 Hp , Automatic Push Button Starter Pannel Cutler Hammer 15 Hp , Automatic Push Button Starter Pannel Cutler Hammer 20 Hp , Cut Out With Basemake Ssk-16 Amp , Cut Out With Basemake Ssk-32 Amp , Cut Out With Basemakessk-63 Amp , Cut Out With Basemake Ssk-100 Amp , Cut Out With Basemake Ssk-200 Amp , Cut Out With Basemake Ssk-400 Amp , Pvc Wire-Copper Anchor/Havvels-.3/20 , Pvc Wire Coppe Anchor/Havvels 7/16 , Pvc Wire-Copper Anchor/Havvels.7/20 , Pvc Wire-Copper Anchor/Havvels.19/16 , Main Switch Tphavvels Make 16 Amp , Main Switch Tphavvels Make 32 Amp , Main Switch Tphavvels Make63 Amp , Main Switch Tphavvels Make 100 Amp , Main Switch Tphavvels Make 200 Amp , Main Switch Tphavvels Make 400 Amp , Gi Wire All Guage Galvanized Hotdrip , Submersible Cable Flat 3Core Finolex-1.5 Sqmm , Submersible Cable Flat 3Core Finolex-2.5 Sqmm , Submersible Cable Flat 3Core Finolex-4 Sqmm , Submersible Cable Flat 3Core Finolex-6 Sqmm , Capacitor 415 Volt Isi Mark(Crompton/Siemens) Make, Mpp Type , Pvc Armoured Cable Aluminium 3Core National-4 Sqmm , Pvc Armoured Cable Aluminium 3Core National-6 Sqmm , Pvc Armoured Cable Aluminium 3Core National-8 Sqmm , Pvc Armoured Cable Aluminium 3Core National-10 Sqmm , Pvc Armoured Cable Aluminium 3Core National-16 Sqmm , Pvc Armoured Cable Aluminium 3Core National-25 Sqmm , Pvc Armoured Cable Aluminium 3Core National-60 Sqmm , Pvc Armoured Cable Aluminium 3Core National-100 Sqmm , Pvc Armoured Cable Aluminium 3Core National-120 Sqmm , Pvc Armoured Cable Aluminium 3Core National-200 Sqmm , Pvc Armoured Cable Aluminium 3Core National-300 Sqmm , Pvc Armoured Cable Aluminium 3Core National-400 Sqmm , Pvc Armoured Cable Aluminium 3Core National-500 Sqmm , Capacitor 415Volt L&T Make Isi ,Mpp Type , Steel Bush Heavy For Tube Well Forged-1¼X1½ , Steel Bush Heavy For Tube Well Forged-1½X2 , Steel Bush Heavy For Tube Well Forged-2X2½ , Steel Bush Heavy For Tube Well Forged-2½X3 , Steel Bush Heavy For Tube Well Forged-2X3 , Steel Grip Tape Anchor Make -15Mm (½) , Steel Grip Tape Anchor Make -20Mm (¾) , Nut Bolt All Sizes Full & Half Thread WMake- , Gi Long Socket Heavy For Submersible Pump Bharat Make- 32Mm (1¼) , Gi Long Socket Heavy For Submersible Pump Bharat Make- 40Mm (1½) , Gi Long Socket Heavy For Submersible Pump Bharat Make- 50Mm (2) , Gi Long Socket Heavy For Submersible Pump Bharat Make- 65Mm (2½) , Gi Long Socket Heavy For Submersible Pump Bharat Make- 80Mm (3) , Well Cap For Tube Well Mildsteel-125Mm (5) , Well Cap For Tube Well Mildsteel-150Mm (6) , Well Cap For Tube Well Mildsteel-180Mm (7) , Well Cap For Tube Well Mildsteel-200Mm (8) , M S Clamp For Tube Well Mildsteel-32Mm (1¼) , M S Clamp For Tube Well Mildsteel-40Mm (1½) , M S Clamp For Tube Well Mildsteel-50Mm (2) , M S Clamp For Tube Well Mildsteel-65Mm (2½) , M S Clamp For Tube Well Mildsteel-80Mm (3) , Cable Joint Rubber Role Dunlop- , Pvc Flexible Pipe Shrinath-40Mm (1¼) , Pvc Flexible Pipe Shrinath-50Mm (1½) , Earth Plate Heavycopper-1X1 Ft , Earth Plate Heavygalvanized-1X1 Ft , No Volt Coil For Starter L&T/Hammer Cuttler-3 To 7-5 Hp , No Volt Coil For Starter L&T/Hammer Cuttler-10 To 20 Hp , Soldring Alkapy Ambika/Khosla-60/40 , Soldring Wire Ambika/Khosla-60/40 , Flux Bottel 181 Isi , Spare Point Kit For Starter L&T/Hammer Cuttler -3 To 7-5 Hp , Spare Point Kit For Starter L&T/Hammer Cuttler-10 To 20 Hp , Copper Patti/Rod Superier Quality- , Bekalite Sheet All Size Heavy Pressed- , Ms Steel Sheet Box 20Gage Incl Plyboard, Angle Stand & With Lock Fabricated- Size 4X 4 X 2 , Ms Steel Sheet Box 20Gage Incl Plyboard, Angle Stand & With Lock Fabricated-Size2x2 , Gland Packing All Size Turner / Champion Make- , Over Load Relay For Starter L&T Make 9 - 14 Amp , Over Load Relay For Starter L&T Make14 - 21 Amp , Over Load Relay For Starter Cuttler Hammer Make 9 - 14 Amp , Over Load Relay For Starter Cuttler Hammer Make 14- 21Amp , Contactor For Automatic Starter L&T Make-25 Amp , Contactor For Automatic Starter L&T Make-40 Amp , Contactor For Automatic Starter Cuttler Hammer Make-25 Amp , Contactor For Automatic Starter Cuttler Hammer Make-40 Amp , Service Line Single Phase Aluminium Wire National-6 Sqmm , Suction Pipe Heavy Duty Pvc Make Premier/Equilent-40Mm (1¼) , Suction Pipe Heavy Duty Pvc Make Premier/Equilent-50Mm (1½) , Suction Pipe Heavy Duty Pvc Make Premier/Equilent-63Mm (2) , Suction Pipe Heavy Duty Pvc Make Premier/Equilent-75Mm (2½) , Suction Pipe Heavy Duty Pvc Make Premier/Equilent-80Mm (3) , Suction Pipe Heavy Duty Pvc Make Premier/Equilent-110Mm (4) , Steel Flange Table-D-50Mm (2) , Steel Flange Table-D-65Mm (2½) , Steel Flange Table-D-80Mm (3) , Steel Flange Table-D-100Mm (4) , Steel Flange Table-D-150Mm (6) , Rubber Sheet All Thickness Oxford/Orient-White , Rubber Sheet All Thickness Oxford/Orient-Black , Ampere Meter All Amp Essma-150Mm (6) , Ampere Meter All Amp Essma-100Mm (4) , Ampere Meter All Amp Essma-65Mm (2½) , Volt Meter 0.500 Volt Essma-150Mm (6) , Volt Meter 0.500 Volt Essma-100Mm (4) , Volt Meter 0.500 Volt Essma-65Mm (2½) , Starter For Single Phase Paramount/Equilent-1 H.P. , Starter For Single Phase Paramount/Equilent-1½ H.P. , Starter For Single Phase Paramount/Equilent -2 H.P. , Auxilary Switch - For All Starter , Button For Starter-5 H.P.To 20 H.P. , Button For Starter Above 20 H P , Hose Clamp -25Mm (1) , Hose Clamp -32Mm (1¼) , Hose Clamp -40Mm (1½) , Hose Clamp -50Mm (2) , Hose Clamp -65Mm (2½) , Hose Clamp-80Mm (3) , Hose Nipple Heavy Long -25Mm (1) , Hose Nipple Heavy Long -32Mm (1¼) , Hose Nipple Heavy Long -40Mm (1½) , Hose Nipple Heavy Long -50Mm (2) , Hose Nipple Heavy Long -65Mm (2½) , Hose Nipple Heavy Long -80Mm (3) , Plastic Coated Wire 6 Mm Rope For Hdpe Pipe- , Converson Head Complete With Handle,Axel,Bearing, Chain Complete For India Mark Ll Hand Pump , India Mark Ll Unicef Heavy Design Hand Pump Machine Complete Assembly Isi- Galvnized , Handle Complete With Bearing, Axel, Chain, Complete For India Mark 2Hand Pump Galvnized , Water Chamber Heavy For India Mark 2.-Hand Pump Galvnized , Pedistal Heavy For India Mark 2.-Hand Pump Galvnized , Cylinder Complete For India Mark 2.-Hand Pump Complete Heavy , Plunjer Rod Stainless Steel Heavy-For Cylinder , Reducer Cap- For Cylinder , Upper Valve Assembly Gm With Upper Valve Guide, Spacergun Metel Heavy-For Cylinder , Lower Valve Assembly With Rubber Sheetgun Metal For Cylinder , Handle Axle Stainless Steel India Mark Ll- Hand Pump , Ball Bearing 6204 Mark Ll Double Sealed Nbc/Equilent- , Front Cover Galvanized Heavy- , High-Tension Bolt Galvanized- , Pipe Socket 1 1/4 Isi Gi Heavy- , Upper Valve Guide Mark Ll Gm , Rubber Washer Mark Ll Superior-Quality , Conversion Head Center Plate Galvanized- , Hex Nut Bolt Galvanized-10Mmx40mm , Connecting Rod Galvanized 12 Mmx3mtr Heavy- , Leather Washer Bucket Shakti Make-Mark Ll , Chain With Coupler Mark Ll Heavy , Rod Socket 12 Mm Galvanized- , Motor Varnish- , Bearing Grease Ap3 Or Imi , Squarebush For Pump Coupling 200Hp , Squarebush For Pump Coupling 150Hp , Square Bush For Pump Coupling 120Hp , Square Bush For Pump Coupling 100Hp , Square Bush For Pump Coupling 60Hp , Square Bush For Pump Coupling 50Hp , Square Bush For Pump Coupling 40Hp , Square Bush For Pump Coupling 25Hp, 20Hp 30Hp , Square Bush For Pump Coupling 15Hp , Square Bush For Pump Coupling 10Hp , Square Bush For Pump Coupling 5Hp , Square Bush For Pump Coupling 3Hp , Starter Panel For Single Phase Motor Pump With Ampmeter & Volt Meter- 1Hp , Starter Panel For Single Phase Motor Pump With Ampmeter & Volt Meter- 1.50Hp , Starter Panel For Single Phase Motor Pump With Ampmeter & Volt Motor- 2Hp , Contactor Point Set For Starter 150 Hp , Transformer Oil B Grade Super Quality- Isi , Nailsall Sizes- , Alluminium Lugs Heavy Dowells-30 Sqmm , Alluminium Lugs Heavy Dowells-40 Sqmm , Alluminium Lugs Heavy Dowells-50 Sqmm , Alluminium Lugs Heavy Dowells-60 Sqmm , Alluminium Lugs Heavy Dowells-70 Sqmm , Alluminium Lugs Heavy Dowells-80 Sqmm , Alluminium Lugs Heavy Dowells-90 Sqmm , Alluminium Lugs Heavy Dowells-100 Sqmm , Alluminium Lugs Heavy Dowells-200 Sqmm , Alluminium Lugs Heavy Dowells-300 Sqmm , Alluminium Lugs Heavy Dowells-400 Sqmm , Alluminium Lugs Heavy Dowells-500 Sqmm , Alluminium Lugs Heavy Dowells-800 Sqmm , Copper Lugs Heavy Dowells-15Sqmm , Copper Lugs Heavy Dowells-30Sqmm , Copper Lugs Heavy Dowells-40 Sqmm , Copper Lugs Heavy Dowells-50 Sqmm , Copper Lugs Heavy Dowells-60 Sqmm , Copper Lugs Heavy Dowells-70 Sqmm , Copper Lugs Heavy Dowells-80 Sqmm , Copper Lugs Heavy Dowells-90 Sqmm , Copper Lugs Heavy Dowells-100 Sqmm , Copper Lugs Heavy Dowells-200 Sqmm , Copper Lugs Heavy Dowells-300 Sqmm , Copper Lugs Heavy Dowells-400 Sqmm , Copper Lugs Heavy Dowells-500 Sqmm , Copper Lugs Heavy Dowells-800 Sqmm , Araldite , Wire Brush Heavy Duty- Iron , Wire Brush Heavy Duty-Plastic , Wire Brush Heavy Duty- Brass , Plastic Tokni- , Flower Broom , Stick Broom , Exhaust Fan Gec / Crompton Make 450Mm , Exhaust Fan Gec / Crompton-600Mm (24) , Exhaust Fan Gec / Crompton-900Mm (36) , Foot Valve Heavy Isi Mark-50Mm (2) , Foot Valve Heavy Isi Mark-80Mm (3) , Foot Valve Heavy Isi Mark-100Mm (4) , Foot Valve Heavy Isi Mark-150Mm (6) , Foot Valve Heavy Isi Mark-200Mm (8) , Foot Valve Heavy Isi Mark-250Mm (10) , Foot Valve Heavy Isi Mark-300Mm (12) , Mobile Oil-20 No. Castrol /Servo , Mobile Oil-40 No.Castrol /Servo , Mobile Oil-60 No.Castrol / Servo , Mobile Oil-80 No.Castrol/Servo , Mobile Oil-90 No.Castrol/Servo , Mobile Oil-100 No. Castrol /Servo , Mobile Oil-150 No. Castrol /Servo , Mobile Oil-320 No. Castrol /Servo , Cleaning Powder , Cement Fencing Pole- , Barbed Wire , Shockproof Rubber Mating For 11000 Volt 1M.X 2M- , Die Set-1 To ½ Complete Hira Make , Die Set-1¼ To 2 Complete Hira Make , Tap-50Mm (2) , Tap-40Mm (1½) , Tap-32Mm (1¼) , Tap-25Mm (1) , Tap-20Mm (¾) , Tap-15Mm (½) , Pipe Wrench-900Mm (36) Make Taparia , Pipe Wrench-600Mm (24) Make Taparia , Pipe Wrench-450Mm (18) Make Taparia , Pipe Wrench-350Mm (14) Make Taparia , Pipe Wrench-300Mm (12) Make Taparia , Chain Wrench-150Mm (6) Make Hira , Chain Wrench-100Mm (4) Make Hira , Chain Wrench-80Mm (3) Make Hira , Fix Spanner Set-6 No.- To 32 No- Taparia , Ring Spanner Set-6 No.- To 32 No-Taparia , Hexa Frame Hira Make , Hexa Blade Single , Crowbar (Sabbal) Tata Make , Hammer 2 Lbs , Hammer 4 Lbs , Hammer 6 Lbs , Hammer 8 Lbs , Hammer 10 Lbs , Gainti Heavy Duty , Tasla (Ghamela) Heavy Guage , Gi Pipe A Classisi Mark Without Socket - Jadia Or Equilent -15Mm (½) , Gi Pipe A Class Isi Mark Without Socket - Jadia Or Equilent -20Mm (¾) , Gi Pipe A Class Isi Mark Without Socket - Jadia Or Equilent -25Mm (1) , Gi Pipe A Class Isi Mark Without Socket - Jadia Or Equilent -32Mm (1¼) , Gi Pipe A Class Isi Mark Without Socket- Jadia Or Equilent -40Mm (1½) , Gi Pipe A Class Isi Mark Without Socket - Jadia Or Equilent -50Mm (2) , Gi Pipe A Classisi Mark Without Socket - Jadia Or Equilent -65Mm (2½) , Gi Pipe A Class Isi Mark Without Socket - Jadia Or Equilent -80Mm (3) , Gi Pipe A Class Isi Mark Without Socket - Jadia Or Equilent -100Mm (4) , Gi Pipe B Class Isi Mark Without Socket - Jadia Or Equilent -15Mm (½) , Gi Pipe B Class Isi Mark Without Socket - Jadia Or Equilent -20Mm (¾) , Gi Pipe B Class Isi Mark Without Socket - Jadia Or Equilent -25Mm (1) , Gi Pipe B Class Isi Mark Without Socket - Jadia Or Equilent -32Mm (1¼) , Gi Pipe B Class Isi Mark Without Socket - Jadia Or Equilent -40Mm (1½) , Gi Pipe B Class Isi Mark Without Socket - Jadia Or Equilent -50Mm (2) , Gi Pipe B Class Isi Mark Without Socket - Jadia Or Equilent -65Mm (2½) , Gi Pipe B Class Isi Mark Without Socket - Jadia Or Equilent -80Mm (3) , Gi Pipe B Class Isi Mark Without Socket - Jadia Or Equilent -100Mm (4) , Gi Pipe B Class Isi Mark Without Socket - Jadia Or Equilent -150Mm (6) , Gi Elbow Isi Mark Kirti, Vimco Or Equilent -15Mm (½) , Gi Elbow Isi Mark Kirti, Vimco Or Equilent -20Mm (¾) , Gi Elbow Isi Mark Kirti, Vimco Or Equilent -25Mm (1) , Gi Elbow Isi Mark Kirti, Vimco Or Equilent -32Mm (1¼) , Gi Elbow Isi Mark Kirti, Vimco Or Equilent -40Mm (1½) , Gi Elbow Isi Mark Kirti, Vimco Or Equilent -50Mm (2) , Gi Elbow Isi Mark Kirti, Vimco Or Equilent -65Mm (2½) , Gi Elbow Isi Mark Kirti, Vimco-80Mm (3) , Gi Elbow Isi Mark Kirti, Vimco-100Mm (4) , Gi Elbow Isi Mark Kirti, Vimco-150Mm(6) , Gi Socket Isi Mark-15Mm (½) , Gi Socket Isi Mark-20Mm (¾) , Gi Socket Isi Mark-25 (1) , Gi Socket Isi Mark-32Mm (1¼) , Gi Socket Isi Mark-40Mm (1½) , Gi Socket Isi Mark-50Mm (2) , Gi Socket Isi Mark-65Mm (2½) , Gi Socket Isi Mark-80Mm (3) , Gi Socket Isi Mark-100Mm (4) , Gi Socket Isi Mark-150Mm (6) , Gi Union Kirti, Vimco-15Mm (½) , Gi Union Kirti, Vimco-20Mm (¾) , Gi Union Kirti, Vimco-25Mm (1) , Gi Union Kirti, Vimco-32Mm (1¼) , Gi Union Kirti, Vimco-40Mm (1½) , Gi Union Kirti, Vimco-50Mm (2) , Gi Union Kirti, Vimco-65Mm (2½) , Gi Union Kirti, Vimco-80Mm (3) , Gi Union Kirti, Vimco-100Mm (4) , Gi Union Kirti, Vimco-150Mm (6) , Gi Tee Kirti, Vimco-15Mm (½) , Gi Tee Kirti, Vimco-20Mm (¾) , Gi Tee Kirti, Vimco-25Mm Mm (1) , Gi Tee Kirti, Vimco-32Mm (1¼) , Gi Tee Kirti, Vimco-40Mm (1½) , Gi Tee Kirti, Vimco-50Mm (2) , Gi Tee Kirti, Vimco-65Mm (2½) , Gi Tee Kirti, Vimco-80Mm (3) , Gi Tee Kirti, Vimco-100Mm (4) , Gi Tee Kirti, Vimco-150Mm (6) , Gi Tank Nipple-15Mm (½) , Gi Tank Nipple-20Mm (¾) , Gi Tank Nipple-25Mm Mm (1) , Gi Tank Nipple-32Mm (1¼) , Gi Tank Nipple-40Mm (1½) , Gi Tank Nipple-50Mm (2) , Steel Hex Nipple-15Mm (½) , Steel Hex Nipple-20Mm (¾) , Steel Hex Nipple-25Mm (1) , Steel Hex Nipple-32Mm (1¼) , Steel Hex Nipple-40Mm (1½) , Steel Hex Nipple-50Mm (2) , Steel Hex Nipple-65Mm (2½) , Steel Hex Nipple-80Mm (3) , Steel Hex Nipple-100Mm (4) , Steel Hex Nipple-150Mm (6) , Gm Gate Valveheavy Isi Mark-15Mm (½) , Gm Gate Valveheavy Isi Mark-20Mm (¾) , Gm Gate Valveheavy Isi Mark-25Mm (1) , Gm Gate Valveheavy Isi Mark-32Mm (1¼) , Gm Gate Valveheavy Isi Mark-40Mm (1½) , Gm Gate Valveheavy Isi Mark-50Mm (2) , Gm Gate Valveheavy Isi Mark-65Mm (2½) , Gm Gate Valveheavy Isi Mark-80Mm (3) , Gm Gate Valveheavy Isi Mark-100Mm (4) , Gm Gate Valveheavy Isi Mark-150Mm (6) , Gi Nipple 12 Long Isi Mark Pipe-15Mm (½) , Gi Nipple 12 Long Isi Mark Pipe-20Mm (¾) , Gi Nipple 12 Long Isi Mark Pipe-25Mm (1) , Gi Nipple 12 Long Isi Mark Pipe-32Mm (1¼) , Gi Nipple 12 Long Isi Mark Pipe-40Mm (1½) , Gi Nipple 12 Long Isi Mark Pipe-50Mm (2) , Gi Nipple 12 Long Isi Mark Pipe-65Mm (2½) , Gi Nipple 12 Long Isi Mark Pipe-80Mm (3) , Gi Nipple 12 Long Isi Mark Pipe-100Mm (4) , Gi Nipple 12 Long Isi Mark Pipe-150Mm (6) , Steel Plug Heavy Quality-15Mm (½) , Steel Plug Heavy Quality-20Mm (¾) , Steel Plug Heavy Quality-25Mm (1) , Steel Plug Heavy Quality-32Mm (1¼) , Steel Plug Heavy Quality-40Mm (1½) , Steel Plug Heavy Quality-50Mm (2) , Steel Plug Heavy Quality-65Mm (2½) , Steel Plug Heavy Quality-80Mm (3) , Steel Plug Heavy Quality-100Mm (4) , Steel Plug Heavy Quality-150Mm (6) , Gi Bend Heavy Duty-15Mm (½) , Gi Bend Heavy Duty-20Mm (¾) , Gi Bend Heavy Duty-25Mm (1) , Gi Bend Heavy Duty-32Mm (1¼) , Gi Bend Heavy Duty-40Mm (1½) , Gi Bend Heavy Duty-50Mm (2) , Gi Bend Heavy Duty-65Mm (2½) , Gi Bend Heavy Duty-80Mm (3) , Gi Bend Heavy Duty-100Mm (4) , Gi Bend Heavy Duty-150Mm (6) , Steel Bush-15Mm (½) , Steel Bush-20Mm (¾) , Steel Bush-25Mm (1) , Steel Bush-32Mm (1¼) , Steel Bush-40Mm (1½) , Steel Bush-50Mm (2) , Steel Bush-65Mm (2½) , Steel Bush-80Mm (3) , Steel Bush-100Mm (4) , Steel Bush-150Mm (6) , Gi Reducer Socket-15Mm (½) , Gi Reducer Socket-20Mm (¾) , Gi Reducer Socket-25Mm (1) , Gi Reducer Socket-32Mm (1¼) , Gi Reducer Socket-40Mm (1½) , Gi Reducer Socket-50Mm (2) , Gi Reducer Socket-65Mm (2½) , Gi Reducer Socket-80Mm (3) , Gi Reducer Socket-100Mm (4) , Gi Reducer Socket-150Mm (6) , Gi Reducer Tee - Kirti, Vimco Isi-15Mm (½) , Gi Reducer Tee - Kirti, Vimco Isi-20Mm (¾) , Gi Reducer Tee - Kirti, Vimco Isi-25Mm (1) , Gi Reducer Tee - Kirti, Vimco Isi-32Mm (1¼) , Gi Reducer Tee - Kirti, Vimco Isi-40Mm (1½) , Gi Reducer Tee - Kirti, Vimco Isi-50Mm (2) , Gi Reducer Tee - Kirti, Vimco Isi-65Mm (2½) , Gi Reducer Tee - Kirti, Vimco Isi-80Mm (3) , Gi Reducer Tee - Kirti, Vimco Isi-100Mm (4) , Gi Reducer Tee - Kirti, Vimco Isi-150Mm (6) , Gi Reducer Elbow-15Mm (½) , Gi Reducer Elbow-20Mm (¾) , Gi Reducer Elbow-25Mm (1) , Gi Reducer Elbow-32Mm (1¼) , Gi Reducer Elbow-40Mm (1½) , Gi Reducer Elbow-50Mm (2) , Gi Reducer Elbow-65Mm (2½) , Gi Reducer Elbow-80Mm (3) , Gi Reducer Elbow-100Mm (4) , Gi Reducer Elbow-150Mm (6) , Chisel Heavy-100Mm (4) , Chisel Heavy-150Mm (6) , Chisel Heavy-225Mm (9) , Chisel Heavy-300Mm (12) , Lead Cocking Tool , Rope Cocking Tool , Gaiti Handle , Fawda Handle , Non Return Valve Normex Or Equilent-150Mm (6) , Non Return Valve Normex Or Equilent-200Mm (8) , Non Return Valve Normex Or Equilent-250Mm (10) , Non Return Valve Normex Or Equilent-300Mm (12) , Non Return Valve Normex Or Equilent-80Mm (3) , Non Return Valve Normex Or Equilent-100Mm (4) , Non Return Valve Normex Or Equilent-50Mm (2) , Non Return Valve Normex Or Equilent-350Mm (14) , Non Return Valve Normex Or Equilent-400Mm (16) , Non Return Valve Normex Or Equilent-450Mm (18) , Non Return Valve Normex Or Equilent-500Mm (20) , Non Return Valve Normex Or Equilent-600Mm (24) , Non Return Valve Normex Or Equilent-700Mm (28) , Non Return Valve Normex Or Equilent-750Mm (30) , Non Return Valve Normex Or Equilent-900Mm (36) , Butter Fly Valve Isi Mark-150Mm(6) , Butter Fly Valve Isi Mark-200Mm (8) , Butter Fly Valve Isi Mark-250Mm (10) , Butter Fly Valve Isi Mark-300Mm (12) , Butter Fly Valve Isi Mark-350Mm (14) , Butter Fly Valve Isi Mark-400Mm (16) , Butter Fly Valve Isi Mark-450Mm (18) , Butter Fly Valve Isi Mark-500Mm (20) , Butter Fly Valve Isi Mark-600Mm (24) , Foot Valve Normex Or Equilent -150Mm (6) , Foot Valve Normex Or Equilent-200Mm (8) , Foot Valve Normex Or Equilent-250Mm (10) , Foot Valve Normex Or Equilent-300Mm (12) , Upvc Pipe Ashirwad/Birla -2 , Upvc Adopter 2 , Tublarpipe20ft Length For Cable Support , Security Chain (For Well Pump) , Hdpe Water Storage Tank Plasto,Dhara Or Equilent Make , Ms Pipe Heavy All Sizes- , Open Well Submersible Pump High Head Isi Mark-3 H.P. , Open Well Submersible Pump High Head Isi Mark-5 H.P. , Open Well Submersible Pump High Head Isi Mark-10 H.P. , Hand Gloves Super Quality-33 Kv Load , Hand Gloves Super Quality-11 Kv Load , Chlorinator Monitar Manual Control Specification Clorine Dose 5 Kg Per Hour Completetrail & Testing For Filter Plant , Cp Steel Bib Cock (Chavi) 1/2 Heavy- , Pipe Vice Heavy-2 No. Hira Or Equilent , Pipe Vice Heavy-3 No. Hira Or Equilent , Pipe Lifter 1 1/4- , Pllier Everest / Tapariya -200Mm (8) , Pllier Everest / Tapariya -250Mm (10) , Hamp Rope , Sun- , White Putty -(Safeda) , Ferule Gun Metal H.D , Screw Driver Everest / Tapariya- -150Mm (6) , Screw Driver Everest / Tapariya- -200Mm (8) , Screw Driver Everest / Tapariya- -300Mm (12) , Wash Basin Tap Heavy-15Mm (½) , Ci Tapper Cock-15Mm ½ Long Handle , Brass Bib Cock Heavy-15Mm (½) , Connection Clamp With Nut Bolt-2X1/2 , Connection Clamp With Nut Bolt-3X1/2 , Connection Clamp With Nut Bolt-4X1/2 , Connection Clamp With Nut Bolt-6X1/2 , Connection Clamp With Nut Bolt-8X2/3 , Connection Clamp With Nut Bolt-10X2/3 , Connection Clamp With Nut Bolt-12X2/3/4 , Connection Clamp With Nut Bolt-16X2/3/4/6 , Connection Clamp With Nut Bolt-18X2/3/4/6 , Connection Clamp With Nut Bolt-20X2/3/4/6 , Connection Clamp With Nut Bolt-24X2/3/4/6 , Connection Clamp With Nut Bolt-14X2/3/4/6 , Tyton Rubber-80Mm (3) , Tyton Rubber-100Mm (4) , Tyton Rubber-150Mm (6) , Tyton Rubber-200Mm (8) , Tyton Rubber-250Mm (10) , Tyton Rubber-300Mm (12) , Tyton Rubber-350Mm (14) , Tyton Rubber-400Mm (16) , Tyton Rubber-450Mm(18) , Tyton Rubber-500Mm (20) , Tyton Rubber-600Mm (24) , Tyton Rubber-700Mm (28) , Tyton Rubber-750Mm (30) , C.I. Flexible Coller Coupling, Giffy Joint Heavy-150Mm (6) , C.I. Flexible Coller Coupling, Giffy Joint Heavy-200Mm (8) , C.I. Flexible Coller Coupling, Giffy Joint Heavy-250Mm (10) , C.I. Flexible Coller Coupling, Giffy Joint Heavy-300Mm (12) , C.I. Flexible Coller Coupling, Giffy Joint Heavy-350Mm (14) , C.I. Flexible Coller Coupling, Giffy Joint Heavy-400Mm (16) , C.I. Flexible Coller Coupling, Giffy Joint Heavy-450Mm (18) , C.I. Flexible Coller Coupling, Giffy Joint Heavy-500Mm (20) , C.I. Flexible Coller Coupling, Giffy Joint Heavy-600Mm (24) , C.I. Flexible Coller Coupling, Giffy Joint Heavy-700Mm (28) , C.I. Flexible Coller Coupling, Giffy Joint Heavy-750Mm (30) , C.I. Flexible Coller Coupling, Giffy Joint Heavy-80Mm (3) , C.I. Flexible Coller Coupling, Giffy Joint Heavy-100Mm (4) , C.I. Flexible Coller Coupling, Giffy Joint Heavy-50Mm (2) , Sluice Valve Heavy With Gun Metal Rod Completee Isi Mark- Deepak, Arko, Maya Or Equilent -50Mm (2) , Sluice Valve Heavy With Gun Metal Rod Completee Isi Mark- Deepak, Arko, Maya Or Equilent-80Mm (3) , Sluice Valve Heavy With Gun Metal Rod Completee Isi Mark- Deepak, Arko, Maya Or Equilent-100Mm (4) , Sluice Valve Heavy With Gun Metal Rod Completee Isi Mark- Deepak, Arko, Maya Or Equilent-150Mm (6) , Sluice Valve Heavy With Gun Metal Rod Completee Isi Mark- Deepak, Arko, Maya Or Equilent -200Mm (8) , Sluice Valve Heavy With Gun Metal Rod Completee Isi Mark- Deepak, Arko, Maya Or Equilent -250Mm (10) , Sluice Valve Heavy With Gun Metal Rod Completee Isi Mark- Deepak, Arko, Maya Or Equilent-300Mm (12) , Sluice Valve Heavy With Gun Metal Rod Completee Isi Mark- Deepak, Arko, Maya Or Equilent-400Mm (16) , Sluice Valve Heavy With Gun Metal Rod Completee Isi Mark- Deepak, Arko, Maya Or Equilent-450Mm (18) , Sluice Valve Heavy With Gun Metal Rod Completee Isi Mark- Deepak, Arko, Maya Or Equilent-500Mm (20) , Sluice Valve Heavy With Gun Metal Rod Completee Isi Mark- Deepak, Agro, Maya Or Equilent-600Mm (24) , Sluice Valve Heavy With Gun Metal Rod Completee Isi Mark- Deepak, Agro, Maya Or Equilent-350Mm (14) , C.I. D Joint Complete-80Mm (3) , C.I. D Joint Complete-100Mm (4) , C.I. D Joint Complete-150Mm (6) , C.I. D Joint Complete-200Mm (8) , C.I. D Joint Complete-250Mm (10) , C.I. D Joint Complete-300Mm (12) , C.I. Tail Piece-80Mm (3) , C.I. Tail Piece-100Mm (4) , C.I. Tail Piece-150Mm (6) , C.I. Tail Piece-200Mm (8) , C.I. Tail Piece-250Mm (10) , C.I. Tail Piece-300Mm (12) , C.I. Tail Piece-350Mm (14) , C.I. Tail Piece-400Mm (16) , C.I. Tail Piece-450Mm (18) , C.I. Tail Piece-500Mm (20) , C.I. Tail Piece-600Mm (24) , C.I. Tail Piece-700Mm (28) , C.I. Tail Piece-750Mm (30) , C.I. Tail Piece-900Mm (36) , Road Boring At Site-80Mm (3) , Road Boring At Site-100Mm (4) , Road Boring At Site-150Mm (6) , C.I. Coller-80Mm (3) , C.I. Coller-100Mm (4) , C.I. Coller-150Mm (6) , C.I. Coller-200Mm (8) , C.I. Coller-250Mm (10) , C.I. Coller-300Mm (12) , C.I. Coller-350Mm (14) , C.I. Coller-400Mm (16) , C.I. Coller-450Mm (18) , C.I. Coller-500Mm (20) , C.I. Coller-600Mm (24) , C.I. Coller-700Mm (28) , C.I. Coller-750Mm (30) , C.I. Coller-900Mm (36) , C.I. Bend Isi Mark-80Mm (3) , C.I. Bend Isi Mark-100Mm (4) , C.I. Bend Isi Mark-150Mm (6) , C.I. Bend Isi Mark-200Mm (8) , C.I. Bend Isi Mark-250Mm (10) , C.I. Bend Isi Mark-300Mm (12) , C.I. Bend Isi Mark-350Mm (14) , C.I. Bend Isi Mark-400Mm (16) , C.I. Bend Isi Mark-450Mm (18) , C.I. Bend Isi Mark-500Mm (20) , C.I. Bend Isi Mark-600Mm (24) , C.I. Bend Isi Mark-700Mm (28) , C.I. Bend Isi Mark-750Mm (30) , C.I. Bend Isi Mark-900Mm (36) , C.I. Pipe Isi Class La Mark-150Mm (6) , C.I. Pipe Isi Class La Mark-200Mm (8) , C.I. Pipe Isi Class La Mark-250Mm (10) , C.I. Pipe Isi Class La Mark-300Mm (12) , C.I. Pipe Isi Class La Mark-350Mm (14) , C.I. Pipe Isi Class La Mark-400Mm (16) , C.I. Pipe Isi Class La Mark-450Mm (18) , C.I. Pipe Isi Class La Mark-500Mm (20) , C.I. Pipe Isi Class La Mark-600Mm (24) , C.I. Pipe Isi Class La Mark-700Mm (28) , C.I. Pipe Isi Class La Mark-750Mm (30) , C.I. Tee Isi Mark-150Mm (6) , C.I. Tee Isi Mark-200Mm (8) , C.I. Tee Isi Mark-250Mm (10) , C.I. Tee Isi Mark-300Mm (12) , C.I. Tee Isi Mark-350Mm (14) , C.I. Tee Isi Mark-400Mm (16) , C.I. Tee Isi Mark-450Mm (18) , C.I. Tee Isi Mark-500Mm (20) , C.I. Tee Isi Mark-600Mm (24) , C.I. Tee Isi Mark-80Mm (3) , C.I. Tee Isi Mark-100Mm (4) , C.I. Tee Isi Mark-700Mm (28) , C.I. Tee Isi Mark-750Mm (30) , Fawda Tata- , 25 Hp Centrifugal Pump Set Split Casing Type 50 Meter Head Delivery 5 Suction 6- Kirloskar / Euilent Isi Mark. , Mono Block Pump Set Head 40 Meter Discharge 2000 Gph 5 Hp Kirloskar Or Equilent Isi Mark- , Mono Block Pump Set Head 60 Meter Discharge 3500 Gph 10 Hp Kirloskar Or Equilent Isi Mark , Mono Block Pump Set Head 80 Meter Discharge 5000 Gph 15 Hp Kirloskar Or Equilent Isi Mark , Mono Block Pump Set Head 80 Meter Discharge 7500 Gph 30 Hp Kirloskar Or Equilent Isi Mark , Diesel Engine Pump Set Complete Kirloskar / Equilent Isi Mark-5 H.P. , Diesel Engine Pump Set Complete Kirloskar / Equilentisi Mark-10H.P , Diesel Engine Pump Set Complete Kirloskar / Equilentisi Mark-15 H.P. , Diesel Engine Pump Set Complete Kirloskar / Equilent Isi Mark-20 H.P. , Contactor 3 Phase 415 Volt L&T Starter- Ml-12 , Contactor 3 Phase 415 Volt L&T Starter- Ml-10 , Contactor 3 Phase 415 Volt L&T Starter- Ml-4 , Contactor 3 Phase 415 Volt L&T Starter- Ml-3 , Contactor 3 Phase 415 Volt L&T Starter- Ml-2 , Contactor 3 Phase 415 Volt L&T Starter- Ml-1.5 , Chain Pully Block Spur Gear 6 Meter Chain Heavy-2 Tonn Isi Mark , Chain Pully Block Spur Gear 6 Meter Chain Heavy-3Tonn Isi Mark , Chain Pully Block Spur Gear 6 Meter Chain Heavy-5 Tonn Isi Mark , Power Control Switch 3 Phase L&T 415 Volt-Fn-32 , Power Control Switch 3 Phase L&T 415 Volt-Fn-63 , Power Control Switch 3 Phase L&T 415 Volt-Fn-100 , Power Control Switch 3 Phase L&T 415 Volt- Fn 250 , Power Control Switch 3 Phase L&T 415 Volt-Fn 400 , Timer 3 Phase 415 Volt L&T-Electronic Timer 3-10 Sec. , Timer 3 Phase 415 Volt L&T-Thermal Timer3-10 Sec. , Over Load Relay 3 Phase L&T-45-75 Amp , Over Load Relay 3 Phase L&T- Mn12 180-300 Amp , Over Load Relay 3 Phase L&T- 2-5-4.0 Amp , Spare For Starter 415 Volt L&T-Moving Contact 2500 Amp , Spare For Starter 415 Volt L&T-Fix Contact 2500 Amp , Spare For Starter 415 Volt L&T-Moving Contact 1250 Amp , Spare For Starter 415 Volt L&T-Fix Contact 1250 Amp , Spare For Starter 415 Volt L&T-Moving Contact1000 Amp , Spare For Starter 415 Volt L&T-Fix Contact 1000 Amp , Spare For Starter 415 Volt L&T-Moving Contact 800 Amp , Spare For Starter 415 Volt L&T-Fix Contact 800 Amp , Pump Moter Set 80 Meter High Head Kirloskar / Equilent Make Or Other Isi Mark-5Hp , Pump Moter Set 80 Meter High Head Kirloskar / Equilent Make Or Other Isi Mark-10Hp , Pump Moter Set 80 Meter High Head Kirloskar / Equilent Make Or Other Isi Mark-15 Hp , Pump Moter Set 80 Meter High Head Kirloskar / Equilent Make Or Other Isi Mark-20 Hp , Pump Moter Set 80 Meter High Head Kirloskar / Equilent Make Or Other Isi Mark-30 Hp , Current Transformer-Amp 2500/2000/5 , Current Transformer-Amp 1250/1000/5 , Current Transformer-Amp1000/800/5 , Current Transformer-Amp 1200/5 , Current Transformer-Amp 1000/5 , Current Transformer-Amp 800/5 , Current Transformer-Amp 600/5 , Current Transformer-Amp 500/5 , Current Transformer-Amp 400/5 , Current Transformer-Amp 200/5 , Spare Point Kit For 3 Phase Starter-Ml 12 L&T , Spare Point Kit For 3 Phase Starter-Ml 10 L&T , Spare Point Kit For 3 Phase Starter-Ml 4 L&T , Spare Point Kit For 3 Phase Starter-Ml 3 L&T , Spare Point Kit For 3 Phase Starter-Ml 2 L&T , Hrc Fuse 415 Volt L&T & Isi Mark-630 Amp , Hrc Fuse 415 Volt L&T & Isi Mark-400 Amp , Hrc Fuse 415 Volt L&T & Isi Mark-250 Amp , Hrc Fuse 415 Volt L&T & Isi Mark-200 Amp , Hrc Fuse 415 Volt L&T & Isi Mark-100 Amp , Hrc Fuse 415 Volt L&T & Isi Mark-80 Amp , Hrc Fuse 415 Volt L&T & Isi Mark-63 Amp , Hrc Fuse 415 Volt L&T & Isi Mark-50 Amp , Hrc Fuse 415 Volt L&T & Isi Mark-25 Amp , Hrc Fuse 415 Volt L&T & Isi Mark-20 Amp , Hrc Fuse 415 Volt L&T & Isi Mark-10 Amp , Hrc Fuse 415 Volt L&T & Isi Mark-6 Amp , Painting Brush-50Mm (2) , Painting Brush-80Mm (3) , Painting Brush-100Mm (4) , Painting Brush-125Mm (5) , Painting Brush-150Mm (6) , Synthetic Enamel Paint All Colour Asian/Berger Or Equilent , Alluminium Paint Asian / Berger Or Equilent , Red Oxide Paint- , Tarpine Oil- , Rubber Paint-Superior Quality Isi , White Cement 50 Kg Packing- Birla Or Equilent , Snowcem 25 Kg Packing-Asian, Berger Or Equilent , Oil Bound Distemper-Asian,Berger Or Equilent , Ball Bearing Skf/Nbc Or Equilent 6323 , Ball Bearing Skf/Nbc Or Equilent 6322 , Ball Bearing Skf/Nbc Or Equilent 6321 , Ball Bearing Skf/Nbc Or Equilent 6320 , Ball Bearing Skf/Nbc Or Equilent 6318 , Ball Bearing Skf/Nbc Or Equilent 6316 , Ball Bearing Skf/Nbc Or Equilent 6315 , Ball Bearing Skf/Nbc Or Equilent 6314 , Ball Bearing Skf/Nbc Or Equilent 6312 , Ball Bearing Skf/Nbc Or Equilent 6311 , Ball Bearing Skf/Nbc Or Equilent 6310 , Ball Bearing Skf/ Nbc Or Equilent 6309 , Ball Bearing Skf/ Nbc Or Equilent 6308 , Ball Bearing Skf/Nbc Or Equilent 6307 , Ball Bearing Skf/Nbc Or Equilent 6306 , Ball Bearing Skf/Nbc Or Equilent 6305 , Double Ball Bearing Skf/Nbc Or Equilent-3310 , Double Ball Bearing Nbc Or Equilent 3307 , Thrust Ball Bearing Nbc Or Equilent 51313 , Angular Ball Bearing Nbc Or Equilent 7222 , Angular Ball Bearing Nbc Or Equilent 7220 , Angular Ball Bearing Nbc Or Equilent 7215 , Angular Ball Bearing Nbc Or Equilent 7210 , Angular Ball Bearing Nbc Or Equilent 7309 , Angular Ball Bearing Nbc Or Equilent 7308 , Ball Bearing Skf / Nbc Or Equilent Ball Bearing-6406 , Ball Bearing Skf / Nbc Or Equilent Ball Bearing-6407 , Spherical Roller Bearing 30212 Nbc Or Equilent , Spherical Roller Thrust Bearing-29330 E Nbc Or Equilent , Spherical Roller Thrust Bearing-29326 B Nbc Or Equilent , Spherical Roller Thrust Bearing-29328 B Nbc Or Equilent , Single Roller Bearing Imported / Skf- Or Equilent Crm 36 , Single Roller Bearing Imported/ Skfor Equilent Crm 34 , Roller Bearing Skf / Nbc Or Equilent-3310 , Roller Bearing Skf/ Nbc Or Equilent 3309 , Ball Bearingskf/Nbc Or Equilent -Ms 12½ , Single Roller Bearing Skf Or Equilent -N. 313 , Double Roller Bearing Skf Or Equilent-22311-K , Double Roller Bearing Skf Or Equilent-22313-K , Double Roller Bearing Skf Or Equilent-2309 , Double Roller Bearing Skf Or Equilent2309 K , Roller Bearing-6322 Skf/Nbc Or Equilent , Roller Bearing-6321 Skf/Nbc Or Equilent , Roller Bearing-6323 Skf/Nbc Or Equilent , Roller Bearing Skf-C.R.M. 18Skf/Nbc Or Equilent , Roller Bearing Skf-13½V3 Skf/Nbc Or Equilent , Ball Bearing Skf/Nbc Or Equilent -6411 , Double Roller Bearing Nbc/ Skf Or Equilent -22315 , Double Roller Bearing Nbc/ Skf Or Equilent -Nu 315 , Galvanized Sheet-3 X12 Ft. , Galvanized Sheet-2½ X 10 Ft. , Galvanized Sheet-3X6 Ft. , Galvanized Sheet-3X8 Ft. , Cement Sheet-3X12 , Cement Sheet-2½ X 10 Ft. , Cement Sheet-3X6 Ft. , Cement Sheet-3X8 Ft. , J Hook- , Angle Iron Fencing Pole2 Meter- , Cementfencing Pole 2 Meter- , Air Circuit Breaker 3 Ph Ac 415V, 50 Hz Draw Out With Cradlemanual Operated Protection Over Load. Earth Fault Short Circuit Over Current Protection With Solid State Analog Release - S R15 Mark L&T/Cromption- Or Equilent 2500Amp , Air Circuit Breaker 3 Ph Ac 415V, 50 Hz Draw Out With Cradlemanual Operated Protection Over Load. Earth Fault Short Circuit Over Current Protection With Solid State Analog Release - Sr15 Mark L&T/Crompton-Or Equilent 1250Amp , Air Circuit Breaker 3 Ph Ac 415V, 50 Hz Draw Out With Cradlemanual Operated Protection Over Load. Earth Fault Short Circuit Over Current Protection With Solid State Analog Release - Sr15 Mark L&T/Crompton-Or Equilent 1000Amp , Air Circuit Breaker 3 Ph Ac 415V, 50 Hz Draw Out With Cradlemanual Operated Protection Over Load. Earthfault Short Circuit Over Current Protection With Solid State Analog Release - Sr15 Mark L&T/Crompton-Or Equilent 800Amp , Acb 3 Ph Ac 415 V 50Hz Fixed Manual Operated Protection Over Load Earth Short Circuit Make L&T /Crompton Or Equilent -Amp 1250 , Acb 3 Ph Ac 415 V 50Hz Fixed Manual Operated Protection Over Load Earth Short Circuit Make L&T /Crompton Or Equilent -Amp 630 , Moulded Case Circuit Breaker 3 Ph Ac 415V Hz Make L&T/Crompton Or Equilent -400A , Moulded Case Circuit Breaker 3 Ph Ac 415V Hz Make L&T/Crompton Or Equilent -630A , Crimpling Tool Complete For Pressing Lugs Of All Size With Die Set-Dowells Or Equilent. , Switch Fuse Unit (Sfu) 3 Ph. Ac-415 V, 50 Hz. Rating- 800 Amps, F.N.800 L&T , Switch Fuse Unit (Sfu) 3 Ph. Ac-415 V, 50 Hz. Rating- 630 Amps, Fn-630 L&T , Switch Fuse Unit (Sfu) 3 Ph. Ac-415 V, 50 Hz. Rating- 400 Amps, Fn-400 L&T , Switch Fuse Unit (Sfu) 3 Ph. Ac-415 V, 50 Hz. Rating- 250 Amps, Fn-250L&T , Switch Fuse Unit (Sfu) 3 Ph. Ac-415 V, 50 Hz. Rating-200 Amps, Fn-200L&T , Switch Fuse Unit (Sfu) 3 Ph. Ac-415 V, 50 Hz. Rating-100 Amps, Fn-100 L&T , Submersible Motor Pump Set Complete Isifor 4 Tube Well Single Phase Discharge 1000 Gph - Usha, Amul, Anchor, Amber Or Equilent-1 Hp , Submersible Motor Pump Set Complete Isi For 4 Tube Well Head 80 To 100 Meter Single Phase Discharge 1000 Gph - Usha, Amul, Anchor, Amber Or Equilent-2 Hp , Submersible Pump Motor Set Complete Isifor 4/5 Tube Well Head 80 To 100 Meter Single Phase Discharge Approx 1000 To 1200 Gph - Usha, Amul, Anchor, Amber Or Equilent-3 Hp , Submersible Pump Motor Set Complete Isifor 4/5 Tube Well Head 80 To 100 Meterdischarge Approx 1500 To 1600 Gph - Usha, Amul, Anchor, Amber Or Equilent-5 Hp , Submersible Pump Motor Set Complete Isi For 4/5 Tube Well Head 80 To 100 Meter Discharge Approx 1800 To 2000 Gph - Usha, Amul, Anchor, Amber Or Equilent -6 Hp , Submersible Pump Motor Set Complete Isi For 4 Tube Well Head 150 Meter Single Phase Discharge Approx 800Gph- Usha, Amul, Anchor, Amber Or Equilent-1 Hp , Submersible Pump Motor Set Complete Isi For 4 Tube Well Head 150 Meter Single Phase Discharge Approx 1000 Gph - Usha, Amul, Anchor, Amber Or Equilent-3 Hp , Submersible Pump Motor Set Complete Isifor 6 Tube Well Head 80 To 100 Meter Discharge Approx 1600 To 1800 Gph - Usha,Amul, Anchor, Amber Or Equilent-6 Hp , Submersible Pump Motor Set Complete Isifor 6 Tube Well Head80 To100 Meter Discharge Approx 2000 Gph - Usha, Amul, Anchor, Amber Or Equilent -7-5 Hp , Submersible Pump Motor Set Complete Isifor 6 Tube Well Head 80 To 100 Meter Discharge Approx 2200 Gph - Usha, Amul, Anchor, Amber Or Equilent-10 Hp , Submersible Pump Motor Set Complete Isifor 6 Tube Well Head 80 To 100 Meter Discharge Approx 2500 Gph - Usha, Amul, Anchor, Amber Or Equilent-12-5 Hp , Submersible Pump Motor Set Complete Isi For 6 Tube Well Head 80 To 100 Meter Discharge Approx 4000 Gph - Usha, Amul, Anchor, Amber Or Equilent-15 Hp , Submersible Pump Motor Set Complete Isi For 6 Tube Well Head 150 Meter Discharge Approx 1800 Gph - Usha, Amul, Anchor, Amber Or Equilent-6 Hp , Submersible Pump Motor Set Complete Isi For 6 Tube Well Head 150 Meter Discharge Approx 2000 Gph - Usha, Amul, Anchor, Amber Or Equilent -7-5 Hp , Power Contactor 3 Ph, Ac-415V, 50 Hz, Coil Volt- 415/230 V,Make L&T Rating550 Amps, Mnx-550 , Power Contactor 3 Ph, Ac-415V, 50 Hz Coil Volt- 415/230 V,Make L&T Rating325 Amps, Mnx-325 , Power Contactor 3 Ph, Ac-415V, 50 Hz Coil Volt- 415/230 V,Make L&T Rating110 Amps, Mnx-110 , Lt Capacitor Type App Leisure Paper And Be Axially, Poly Propylene Film And Um Foil Impregnated With Non Io-Degradable Impregmant As 2834/1986/13585 1994. Make L&T. Crompton, Shakti Or Equilent Ratings-(I) 100 Kvar (25X4) , Lt Capacitor Type App Leisure Paper And Be Axially, Poly Propylene Film And Um Foil Impregnated With Non Io-Degradable Impregmant As 2834/1986/13585 1994. Make L&T. Crompton, Shakti Or Equilentratings-(Ii) 80 Kvar (20X4) , Lt Capacitor Type App Leisure Paper And Be Axially, Poly Propylene Film And Um Foil Impregnated With Non Io-Degradable Impregnate As 2834/1986/13585 1994. Make L&T. Crompton, Shakti Or Equilent Ratings-(Iii) 60 Kvar (20X3) , Lt Capacitor Type App Leisure Paper And Be Axially, Poly Propylene Film And Um Foil Impregnated With Non Io-Degradable Impregnate As 2834/1986/13585 1994. Make L&T. Crompton, Shakti Or Equilentratings-(Iv) 40 Kvar (20X2) , Lt Capacital Type App Lissure Papper And Be Axiallyd, Poly Propyline Film And Um Foil Impregnatrd With Non Io-Degradable Impregmant As 2834/1986/13585 1994. Make L&T. Cromption, Shakti Or Equilentratings-(V) 30 Kvar (15X2) , Bi Metallic Over Load Relay Ct Operated 3 Ph, Ac-415 V, 50 Hz Make L&T Rating- 270-450 Amps, Mn-12 Type , Bi Metallic Over Load Relay Ct Operated 3 Ph, Ac-415 V, 50 Hz Make L&T Rating- 180-300 Amps , Bi Metallic Over Load Relay Ct Operated 3 Ph, Ac-415 V, 50 Hz Make L&T Rating- 135-225 Amps , Phase Failure Relay Vspd-2Minilec- , Pump Guard Relay Minilec 2000- , Electronic Timer, Minilec-(I) Etad - 1 , Electronic Timer, Minilec-(Ii) Ets - D1 , Hrc Fuse Ac - 415 V, 50 Hz Make L&T Rating (I) 630 Amps, - Hn - 3- , No Volt Coil 415/230 V Mark L&T, Rating- 550 Amps, Mnx 550 , No Volt Coil 415/230 V Mark L&T, Rating-325 Amps, Mnx 325 , No Volt Coil 415/230 V Mark L&T, Rating-110 Amps, Mnx 110 , No Volt Coil 415/230 V Mark L&T, Rating-Ml-12, 300 Amps, , No Volt Coil 415/230 V Mark L&T, Rating-200 Amps, Ml-10 , No Volt Coil 415/230 V Mark L&T, Rating- 70 Amps, Ml-4 , Flexible Copper Cable Pvc Insulated-50 Sq Mmisi , Flexible Copper Cable Pvc Insulated-35 Sq Mmisi , Flexible Copper Cable Pvc Insulated-25 Sq Mmisi , Flexible Copper Cable Pvc Insulated-16 Sq Mmisi , Lighting Arrestor 30 Kv 10 Ka Thyrite Magne Valve Station Class Arrester Class Ii-Is: 3070/1993. Iec 99-4/1991 Make - Elpro 33Kv Electrical Station- , Post Insulator 33 Kv-400 Amps, , Post Insulator 22 Kv-200 Amps, , Pin Insulator 33 Kv,- , Disc Insulator 33 Kv- , Spare Contact Point Kit Without No-Volt Coil Of Contactor 3 Ph.Ac, 415 V, Mark L&T, Rating.- 550 Amps, Mnx 550 , Spare Contact Point Kit Without No-Volt Coil Of Contactor 3 Ph Ac, 415 V, Mark L&T, Rating.- 325 Amps, Mnx 325 , Spare Contact Point Kit Without No-Volt Coil Of Contactor 3 Ph.Ac, 415 V, Mark L&T, Rating.-110 Amps, Mnx 110 , Spare Contact Point Kit Without No-Volt Coil Of Contactor 3 Ph.Ac, 415 V, Mark L&T, Rating.- 300 Amps, Ml-12 , Spare Contact Point Kit Without No-Volt Coil Of Contactor 3 Ph.Ac, 415 V, Mark L&T, Rating.- 200 Amps, Ml-10 , Spare Contact Point Kit Without No-Volt Coil Of Contactor 3 Ph.Ac, 415 V, Mark L&T, Rating.- 70 Amps, Ml-4 , Air Break Isolating Switch 33 Kv Dobule Stack Type - (A) Vertical Type -(I) 400 Amps, , Air Break Isolating Switch 33 Kv Dobule Stack Type - (A) Vertical Type -(Ii) 200 Amps, , (B) Rotating Type, 3 Insulator Type -(I) 400 Amps, , (B) Rotating Type, 3 Insulator Type -(Ii) 200 Amps, , Drop Out Fuses Complete Set Of 3 Ph 200 Amps 33 Kva Double Stack Type- , Spares Of Air Break Switch (Horizontal Moving Type)- (I) Moving Contact Blade- , Spares Of Air Break Switch (Horizontal Moving Type)- (Ii) Fix Contact Jaw- , Spares Of Air Break Switch (Horizontal Moving Type)-(Iii) Tinned Copper Jumpher 400 Amps, - , Spares Of Air Break Switch (Horizontal Moving Type)-(Iv) Jumpher Carrier - , Spares Of Air Break Switch (Horizontal Moving Type)-(V) Back Connector Plate. - , Spares Of Air Break Switch (Horizontal Moving Type)-(Vi) E.C.Copper Blade1 1/2X1/4X 40 1/2- , Spares Of Air Break Switch (Horizontal Moving Type)-(Vii) E.C.Copper Contact Element 1 1/4 X 1/8- , Spares Of Air Break Switch (Horizontal Moving Type)-(Viii) E.C.Copper Contact Element 1 1/4 X 1/4- , Spares Of D.O. Fuses. 200 Amps- , (I) Srbp Tube With Metalfitting On Both Ends. - , (Ii) Fiber Glass Tube.- , (Iii) Fix Bottom Contact.- , (Iv) Fix Bottom Contact.- , D.O. Operating Rod Fibre Glass 20 Ft Long In Three Section Complete.- , Drop Out Fuses 33 Kv -25 Amps, , Drop Out Fuses 33 Kv -20 Amps, , Drop Out Fuses 33 Kv -15 Amps, , Drop Out Fuses 33 Kv -10 Amps, , Drop Out Fuses 33 Kv -7.5 Amps, , Drop Out Fuses 33 Kv -5 Amps, , Fiber Glass Discharge Rod 33 Kv-1. 7 Mtr Complete With Pvc Insulated Copper Conductor And Fitting.- , Lighting Arrestor 10 Kv 10 Ka Thyrite Magne Valve Station Class Arrester Class Ii-Is: 3070/1993. Iec 99-4/1991 Make Elpro , Post Insulator 11 Kv-400 Amps, , Post Insulator 11 Kv-200 Amps, , Pin Insulator 11 Kv,- , Disc Insulator 11 Kv- , Air Break Isolating Switch11kv Double Stack Type -(I) 400 Amps, , Vertical Type -(Ii) 200 Amps, , Drop Out Fuses Complete Set Of 11 Kv Single Stack Type- , Drop Out Fuses 11 Kv -25 Amps, , Drop Out Fuses 11 Kv -20 Amps, , Drop Out Fuses 11 Kv -15 Amps, , Drop Out Fuses 11 Kv -10 Amps, , Drop Out Fuses 11 Kv -7.5 Amps, , Drop Out Fuses 11 Kv -5 Amps, , Spares Of Air Break Swich -(I) Moving Contact Blade- , Spares Of Air Break Swich -(Ii) Fix Contact Jaw- , Spares Of Air Break Swich -(Iii) Tinned Copper Flexible Jumpher 400 Amps, - , Spares Of Air Break Swich -(Iv) Jumpher Carrier - , Spares Of Air Break Swich -(V) Back Connector Plate. - , Spares Of Air Break Swich -(Vi) E.C.Copper Blade1 1/2X1/4X 40 1/2- , Spares Of Air Break Swich -(Vii) E.C.Copper Contact Element 1 1/4 X 1/8- , Spares Of Air Break Swich -(Viii) E.C.Copper Contact Element 1 1/4 X 1/4- , Spares Of D.O. Fuses.-(I) Srbp Tube With Metalfitting On Both Ends. - , Spares Of D.O. Fuses.-(Ii) Fiber Glass Tube.- , Spares Of D.O. Fuses.-(Iii) Fix Bottom Contact.- , Spares Of D.O. Fuses.-(Iv) Fix Bottom Contact.- , 11 Kv Porcelains Transformer Bushing 155-3347-1000 Amps , 11 Kv Porcelains Transformer Bushing 155-3347-500 Amps , H.V Brass Metal Part 11 Kv-1000 Amps , H.V Brass Metal Part 11 Kv-500 Amps , Selector Switch 10 Amp-For Ammeter , Selector Switch 10 Amp-For Voltmeter , Copper Lugs Ring Type-95 Mm2 , Copper Lugs Ring Type-120 Mm2 , H.T. Tape , Fiber Bushing 1000 Amp For Supporting Bus Bar- , T.C. Auxiliary Contact 4 Way- , T.C. On-Off Switch 4 Way- , L.T.Phase Seprator-5 Wire L.T. Line , L.T.Phase Seprator-4 Wire L.T. Line , File 12-Flat , File 12-Triangular , File 12-Round , File 12-Half Round , Ringspanner 34-36 Tapria- Or Equilent , Ellen Key (Complete Set)-All Size , Fuse Grip Bakelite 16 Amp- , Power Contact For Switch Fuse Unit- , Moving Contactfor Switch Fuse Unit-F.N. 400 Amp , Moving Contactfor Switch Fuse Unit-F.N. 800 Amp , Fixcontactfor Switch Fuse Unit-F.N. 400 Amp , Fixcontactfor Switch Fuse Unit-F.N. 800 Amp , Auxilary Contact For Contactor-Ml 72/10 , Auxilary Contact For Contactor-550/325 Mhx , Top Housing For Contactor-Ml 4 , Top Housing For Contactor-Ml 10 , Top Housing For Contactor-Ml 12 , Moving Backalite For Contactor-Ml 4 , Moving Backalite For Contactor-Ml 10 , Moving Backalite For Contactor-Ml 12 , H.R.C. Fuse Bolted Type -630 Amp , H.R.C. Fuse Bolted Type -400 Amps, , H.R.C. Fuse Bolted Type -200 Amp , Silica Gel Breather 1 Kg- , Pannel/Starter Indicator Lamp & Holder- , Acsr Dog Conductor 65Mm2 Alluminium- , Carbonsteel Bolt With Two Nut-12X100mm , Carbonsteel Bolt With Two Nut-16X125 Mm , M.C.C.B.-32 Amp , M.C.C.B.-63 Amp , Copper Strip 32X5mm- , Copper Round Bar 8Mm- , Fire Extinguishers (Complete)-Dry Power Chemical Type 5 Kg , Fire Extinguishers (Complete)-A.B. Chemical Type 10 Kg , Main Isolating Contact A.C.B-1000 Amp , Main Isolating Contact A.C.B-1250 Amp , Main Isolating Contact A.C.B-2500 Amp , Secondaryisolating Contact (Fixed)-1000 Amp , Secondaryisolating Contact (Fixed)-1250 Amp , Secondarylsolasting Contact (Fixed)-2500 Amp , 33 Kv Air Breaker Switch (Horizontal Moving Type)-Fix Contact , 33 Kv Air Breaker Switch (Horizontal Moving Type)-Moving Contact Bar , 33 Kv Air Breaker Switch (Link Rod)-Fix Contact , 33 Kv Air Breaker Switch (Link Rod)-Moving Contact Bar , 33 Kv Line-U Clamp , 33 Kv Line-Jumpher Clamp , Window Cooler 18 Usha/Crompton- , Impeller Brass For 150 Hp Kirloskar Pump -Brass , Impeller For 150 Hp Kirloskar Pump -Stainless Steel , Kirloskarsteel Shaft 120 Hp Pump , Squar Bush C-295 For 150 Hp Pump Cupling Joyfiex / Love Toy- , Empty Jute / Hdpe Bags (Empty Cement Bags) , Air Valve Double3 Gmdc Arko- , Air Valve Double4 Gmdc Arko- , Star Coupling Set For 150 Hp Pump Love Joy- , Star Coupling Set For 120 Hp Pump Love Joy- , Starter Point Set For 150 Hp Auto Transformer Starter , Starter Point Set For 120 Hp Auto Transformar Starter L & T- , Star Coupling For 150 Hp Pump Love Joy- , Bench Vice For 8 Mtc- , Bearing Puller 10 Mtc- , Pulli Puller 12 Mtc- , Brass Bolt- 4/8X4 , Brass Bolt- 3/8X4 , Brass Nut-3/8 , Washer Brass-3/8 , Brass Stud-3/4X6 F.T. , Brass Nut-3/4 , Centrifugal Pump Split Type With Suitable Motor Heavy Duty Discharge 1 Lac Gallon Per Hour, Head 80 Meter Impeller Brass Shaft Stainless Steel Bearing Heavy Duty Body Heavy Base Plate Coupling With Foundation Bolt Nut Heavy Duty , Finger Contact Point Big-Mei/Meco , Finger Contact Point Small-Mei/Meco , Finger Contact U Type Patti-Mei/Meco , Ampere Tape- , Oil Paper- , Cotton Tape- , Emery Cloth- , Insulation Tape- , Bakelite Sheet Size 1- , M Seal , Main Switch Hrc Type 200 Amp , Pressed Leather Sheet- , Rubber Bush For Coupling 15 Mm-4X5/8 , Coupling Bolt All Sizes-3X1/2 , Hexa Blade Double As 1 , Hexa Frame , Nut Bolt Tata All Size- , Nut Bolt-All Size , Ms Washer-All Size , Wire Jali All Sizes-Steel , Rubber Sheet White All Sizes Kranti/Orient- , Rubber Sheet Black All Sizes Kranti/Orient- , Ring Spanner Set 6 To 12 -Make Jhalani, Everest , Fix Spanner Set 6 To 12 -Make Jhalani, Everest , Plier 8-Make Jhalani, Everest , 60 Hp Centrifugal Pump 1470Rpm50 Meter Head Complete Set 8X6 Suction Delivery Complete Delivery Item & Starter Kirloskar Or Equilent , 99 % Pig Lead- , Petroleum Jelly- , Transformer Oil Ehv Grade-1 R Power-For Transformer , Bucket Tata 12 Big Size- , Hemp Rope Tool , Lead Wool , 60 Hp Auto Starter 415 Volt 3 Phase Induction Motor Star Delta 1440 Ram-L&T Isi Emi , 50 Hp Auto Starter 415 Volt 3 Phase Induction Motor Star Delta 1440 Ram-L&T Isi Emi , 40 Hp Auto Starter 415 Volt 3 Phase Induction Motor Star Delta 1440 Ram-L&T Isi Emi , 30 Hp Auto Starter 415 Volt 3 Phase Induction Motor Star Delta 1440 Ram-L&T Isi Emi , 20 Hp Auto Starter 415 Volt 3 Phase Induction Motor Star Delta 1440 Ram-L&T Isi Emi , 15 Hp Auto Starter 415 Volt 3 Phase Induction Motor Star Delta 1440 Ram-L&T Isi Emi , Tourch, 3 Cell, Jeep Make With Cell- , Amp Meter 0-100 4- , Amp Meter 0-500 6- , Amp Meter 0-1000 6- , Amp Meter 0-2000 6- , Bench Vice- 10No. , Drill Machine With Stand Size 3 Mm - 15 Mm With Drill With Set Complete-Isi , New Column Pipe Dia 300Mm, Erw Steel, Flange Thickness-25Mm (Min) Bolt Hole Dia - 20 Mm -Length 3.0 Mtr. , New Column Pipe Dia 300Mm, Erw Steel, Flange Thickness-25Mm (Min) Bolt Hole Dia - 20 Mm -Length 2.0 Mtr. , New Column Pipe Dia 300Mm, Erw Steel, Flange Thickness-25Mm (Min) Bolt Hole Dia - 20 Mm -Length 1.50 Mtr. , New Column Pipe Dia 300Mm, Erw Steel, Flange Thickness-25Mm (Min) Bolt Hole Dia - 20 Mm -Length 1.25 Mtr. , New Column Pipe Dia 300Mm, Erw Steel, Flange Thickness-25Mm (Min) Bolt Hole Dia - 20 Mm -Length 1. Mtr. , Steel Reinforced Rubber Ball Of Normex Reflux Valve Dia-250 Mm , Steel Reinforced Rubber Ball Of Normex Reflux Valve Dia-300 Mm , T.V.S. Bolt & Nut Dia. 12 Mm L-65- , T.V.S.Stud Dia. 15 Mm L-75- , Pipe Wrench 36 Rigid Type Make Everest/Tapariya- , Wire Rope Forged U Clamp-Rope Dia 10Mm , Wire Rope Forged U Clamp-Rope Dia 20Mm , Wire Rope Forged U Clamp-Rope Dia 25Mm , Wire Rope Forged U Clamp-Rope Dia 32Mm , Digital Ac/Dc Clamp Meter Make Meco/Kyoritsu Or Equilent-Range Current 20/200/1000/Amps,Voltage 0-230/750V , Digital Ac/Dc Multimeter Model 225 Make Meco Or Equilent -Ac- 750V Ac Current :20Ac: 20 Uf R20m Ohms , High Voltage Insulation Tester Make Meco/Nippen Or Equilent -2000V, 2500M Ohms , High Voltage Insulation Tester Make Meco/Nippen Or Equilent -2500V, 5000M Ohms , High Voltage Insulation Tester Make Meco/Nippen Or Equilent -1000V, 1000M Ohms , 33 Kv Current Transformer For Highest System Voltage 36 Kv Is: 2705/1992-Current Ratio 100/5Amps , 33 Kv Current Transformer For Highest System Voltage 36 Kv Is: 2705/1992-Current Ratio 200/5Amps , Automatic Dc 30 Volt Battery Charger Current Rating 30 Amps (Max) Input 230Vac, 50 Hz Including Battery Box Size 4X3x1.5 & Sheet Gauge 18 And Battery Connector Tb 56 Series 8 Position- 1) Input Cable 3 Core With 15A 3 Pin Plug.- 2) Battery Charger On/Off Rocker Switch 20 Amp With Neon Indication Lamp- 3) Battery Charging Voltage : (1) Auto Mode :I) Boost & Ii) Absorption Mode :Fine Adjustment Range 25.5V To 30V Through Preset On Front Panel Iii) Float Mode : Fine Adjustment Range 28.5V To 30V Through Preset On Front Pane (2) Manual Mode Continuously Adjustable From 26-5V To 30V Through Multiturn Pot- 4)Battery Charging Current : Adjustable From 10% To 100% Of Current Rating With Multitier Pot- 5) Protection : Against Over Load Short Circuit Over Voltage Over Temperature & Reverse Input- 6) Display : (I) Voltmeter: 31/2 Disit Dpm For Displaying Battery/Charger Voltage (Ii) Current Meter: 31/2 Disit Dpm For Displaying Battery/Charger- 7) Indication :Red Forboost Yellow For Absorption Green For Float (Indicating Battery Fully Charged) Red To Indicate Reverse Battery Fully Charged) Red To Indicate Reverse Battery Connection Green For Manual & Auto Mode- , Lead Acid Rechargeable Sub Station Battery Bank 2.1 Volt 20 Ah Make Exide/ Amco Or Equilent , Gas Mask Respirator Canister Type Housed In Body Honessed Canvas Bag And Loaded With Appropriate Chemicals To Neutralize Chlorine Up To 2% Concentration Purified Air Supply Through Air Tight D Or N Type Soft Face Mask With Full Unbreakable Visor And Quick Operatable Head Harness.- , Radicon Gear Box Make Greaves Ltd Or Equilent-V 500 Ratio 50:1 , Radicon Gear Box Make Greaves Ltd Or Equilent-V 400 Ratio 50:1 , Radicon Fear Box Make Greaves Ltd Or Equilent -V 337 Ratio 70:1 , 40 Hp Submersible Pump Motor Set 4 Stage Head:50 Mtr. Discharge -2100 L.P.M. Confirming To Is: 8034-89/ Iso9001-2008-Isi , Ats Pannel Fully Automatic With All Parts Like Relay, Timer, Contactor All L&T For 40 Hp Motor- , Submersible Flat Cable 3X25 Sq. Mm. Is -694-Isi Finolex Or Equilent , 11 Kv Sub Station 4 Pipe Sub Station Structure Guarder Channels Of Sec. (Ishc 200X100&Is Mb 100X10)- , Transformer - 500 Kva, 11/0.44 Kv 3 Phase, Double Wound With Off Dyn 11 Onan Cooled With Off Load Top Changer As Per (Bis 1026 1981 As Per Ie Rules)-Makes Preferred Crompton/Alstom/Bhel/ Kirloskar/Tesla Or Equilent,Rating-500Kv,No Load Voltage Rering (Hv/Lv)-11 Kv/0.44 Kv,Winding Material-Cooper,No, Of Phases-3,Vector-Dy1,Connection On (Hv/Lv)-Delta Star,Frequency-50Hz,Installation-Out Door,Type Of Cooling-Onan,Temp. Rise In Oil By Thermometer-45O,In Winding Of Resistance-55O,Terminal Arrangement-,Primary-Bare,Secondary-Whether Proop Bare Bushing,Type Of Tap Changer Of Load-Off Load Tap Changer,Taps/Step On H.V.-+5%,-15% In Steps Of 1.25%,Fitting & Accessories-Shall Be Provided As Per Bis 2026:1981,Bis 2026 (Part 1 To Iv)-Power Transformer,Bis 3639-Acces & Fitting For Power Transformer,Bis 335-Transformer Oil,Bis 1271-Insulating Material,Bis 2099/Bis3347-Bushings,Bis 1011/Bis 1180-Testing Of Transformers , Vcb 11 Kv 800A 16Ka Out Door Type With Base Structure Along With 6 Nos Terminal Connections- , Acb 11 Kv 250 Amps Triple With Earth Blades Operated Double Break Isolators Horizontal Pose Insulator- , Pennel Board 440 V 3 Phase 50 Hz Indoor Type 1250 Amp Acb, Cts Relay. Timer, Power Control Switch,- , Cable Alluminium Armoure 3X400 Sq. Mmx3½ Core- , Acb Panel Unit 3 Pole 415 V, 1250 Amp,50 Hz, Manually Operated, Draw Out With Cradle, C- Power Make L&T-5 Nos, Fitted With Various Accessories For Control, Signaling & Inter Locking L.E. Shunt Release, Under Voltage Release, Sr-15G, Micro Switch For Fault Signaling Volt & Amp Meters With Selector Switches, Reqd Alluminim Bus Bar & Cable Glands Mounted In 2.1Mx1mx1.05 Fabricated Angle Iron Frame & 16 Saw Cr Sheet Complete Fitting & Trial Testing At Site.- , Supply Errecting & Commissioning Of 750 Kva, 33/43Kv Oil Cooled Transformer Dyn 11 Winding Material Copper, Star Deltaoff Circuit Tap Changer Paint Epoxy Completee With Trial & Testing- , Supply Erecting & Commissioning Of Vacuum Circuit Breaker 36Kv, 1250 Amp 3 Phase Outdoor Type Make Crompton Or Equilent With Indoor Control Pannel Complete Fitting With Trial & Testing- , Mechanical Joints With Rubber Gland Suitable For Ci/Dipipes Dia -150 Mm (6) , Mechanical Joints With Rubber Gland Suitable For Ci/Di Pipes Dia -200 Mm (8) , Mechanical Joints With Rubber Gland Suitable For Ci/Di Pipes Dia -250 Mm(10) , Mechanical Joints With Rubber Gland Suitable For Ci/Di Pipes Dia -300 Mm(12) , Mechanical Joints With Rubber Gland Suitable For Ci/Di Pipes Dia -350 Mm(14) , Mechanical Joints With Rubber Gland Suitable For Ci/Di Pipes Dia -400 Mm(16) , Mechanical Joints With Rubber Gland Suitable For Ci/Di Pipes Dia -450 Mm(18) , Mechanical Joints With Rubber Gland Suitable For Ci/Di Pipes Dia -500 Mm(20) , Mechanical Joints With Rubber Gland Suitable For Ci/Di Pipes Dia -600 Mm(24) , Mechanical Joints With Rubber Gland Suitable For Ci/Di Pipes Dia -700 Mm(28) , Mechanical Joints With Rubber Gland Suitable For Ci/Di Pipes Dia -750 Mm(30) , Mechanical Joints With Rubber Gland Suitable For Ci/Di Pipes Dia -900 Mm(36) , Mechanical Joints With Rubber Gland Suitable For Ci/Di Pipes Dia -1000 Mm(40) , Hdpe Pipe 20Mm - 6Kg/Sqcm- , Hdpe Pipe 25Mm - 6Kg/Sqcm- , Hdpe Pipe 32Mm6kg/Sqcm , Hdpe Pipe 40Mm 6Kg/Sqcm , Hdpe Pipe 50Mm 6Kg/Sqcm , Pe Service Saddle Clamp With Nut Bolts Fitting & Outlet Of 20Mm Dia For Service Connection-90Mm (3) , Pe Service Saddle Clamp With Nut Bolts Fitting & Outlet Of 20Mm Dia For Service Connection-110Mm (4) , Pe Service Saddle Clamp With Nut Bolts Fitting & Outlet Of 20Mm Dia For Service Connection-125Mm (5) , Pe Service Saddle Clamp With Nut Bolts Fitting & Outlet Of 20Mm Dia For Service Connection-160 Mm (6) , Compression Male Threaded Adaptor With Elbow-15Mm (½) , Compression Female Threaded Adaptor -15Mm (½) , Hdpe Detachable Joints-63Mm , Hdpe Detachable Joints-75Mm , Hdpe Detachable Joints-90Mm , Hdpe Detachable Joints-110Mm , Hdpe Detachable Joints-125Mm , Hdpe Detachable Joints-140Mm , Hdpe Detachable Joints-160Mm , Hdpe Detachable Joints-180Mm , Hdpe Detachable Joints-200Mm , Hdpe Detachable Joints-225Mm , Hdpe Detachable Joints-250Mm , Hdpe Pipe Pe 100 6Kg Pressure Is 4984 . 1995-110Mm (4) , Hdpe Pipe Pe 100 6Kg Pressure Is 4984 . 1995-160Mm (6) , Hdpe Pipe Pe 80 6Kg Pressure Is 4984 . 1995-63Mm (2) , Hdpe Pipe Pe 80 6Kg Pressure Is 4984 . 1995-75Mm (2½) , Hdpe Pipe Pe 80 6Kg Pressure Is 4984 . 1995-90Mm (3) , Hdpe Pipe Pe 80 6Kg Pressure Is 4984 . 1995-110Mm (4) , Hdpe Pipe Pe 80 6Kg Pressure Is 4984 . 1995-125Mm , Hdpe Pipe Pe 80 6Kg Pressure Is 4984 . 1995-140Mm , Hdpe Pipe Pe 80 6Kg Pressure Is 4984 . 1995-160Mm , Hdpe Pipe Pe 80 6Kg Pressure Is 4984 . 1995-180Mm , Hdpe Pipe Pe 80 6Kg Pressure Is 4984 . 1995-200Mm , Hdpe Pipe Pe 80 6Kg Pressure Is 4984 . 1995-225Mm , Hdpe Pipe Pe 80 6Kg Pressure Is 4984 . 1995-250Mm , Hdpe Pipe End With Fiange-110Mm , Hdpe Pipe End With Fiange-125Mm , Hdpe Pipe End With Fiange-140Mm , Hdpe Pipe End With Fiange-160Mm , Hdpe Pipe End With Fiange-180Mm , Hdpe Pipe End With Fiange-200Mm , Repair Slip Coupler For Hdpe Pipe-63Mm , Repair Slip Coupler For Hdpe Pipe-75Mm , Repair Slip Coupler For Hdpe Pipe-90Mm , Repair Slip Coupler For Hdpe Pipe-110Mm , Repair Slip Coupler For Hdpe Pipe-125Mm , Repair Slip Coupler For Hdpe Pipe-140Mm , Repair Slip Coupler For Hdpe Pipe-160Mm , Repair Slip Coupler For Hdpe Pipe-180Mm , Repair Slip Coupler For Hdpe Pipe-200Mm , Repair Slip Coupler For Hdpe Pipe-225Mm , Repair Slip Coupler For Hdpe Pipe-250Mm , Cast Iron Leak Repair Clamps With Rubber Insertion & Nut Bolts Lead/Socket Joints-80Mm (3) , Cast Iron Leak Repair Clamps With Rubber Insertion & Nut Bolts Lead/Socket Joints-100Mm (4) , Cast Iron Leak Repair Clamps With Rubber Insertion & Nut Bolts Lead/Socket Joints-125Mm (5) , Cast Iron Leak Repair Clamps With Rubber Insertion & Nut Bolts Lead/Socket Joints-150Mm (6) , Cast Iron Leak Repair Clamps With Rubber Insertion & Nut Bolts Lead/Socket Joints-200Mm (8) , Cast Iron Leak Repair Clamps With Rubber Insertion & Nut Bolts Lead/Socket Joints-250Mm (10) , Cast Iron Leak Repair Clamps With Rubber Insertion & Nut Bolts Lead/Socket Joints-300Mm (12) , Cast Iron Leak Repair Clamps With Rubber Insertion & Nut Bolts Lead/Socket Joints-350Mm (14) , Cast Iron Leak Repair Clamps With Rubber Insertion & Nut Bolts Lead/Socket Joints-400Mm (16) , Cast Iron Leak Repair Clamps With Rubber Insertion & Nut Bolts Lead/Socket Joints-450Mm (18) , Cast Iron Leak Repair Clamps With Rubber Insertion & Nut Bolts Lead/Socket Joints-500Mm (20) , Cast Iron Leak Repair Clamps With Rubber Insertion & Nut Bolts Lead/Socket Joints-600Mm (24) , Cast Iron Leak Repair Clamps With Rubber Insertion & Nut Bolts Lead/Socket Joints-700Mm (28) , Cast Iron Leak Repair Clamps With Rubber Insertion & Nut Bolts Lead/Socket Joints-750Mm (30) , Cast Iron Leak Repair Clamps With Rubber Insertion & Nut Bolts Lead/Socket Joints-900Mm (36) , Cast Iron Leak Repair Clamps With Rubber Insertion & Nut Bolts Lead/Socket Joints-1000Mm , Cast Iron Dismantling Joints With Rubber Insertion & Nut Bilts-80Mm (3) , Cast Iron Dismantling Joints With Rubber Insertion & Nut Bilts-100Mm (4) , Cast Iron Dismantling Joints With Rubber Insertion & Nut Bilts-125Mm (5) , Cast Iron Dismantling Joints With Rubber Insertion & Nut Bilts-150Mm (6) , Cast Iron Dismantling Joints With Rubber Insertion & Nut Bilts-200Mm (8) , Cast Iron Dismantling Joints With Rubber Insertion & Nut Bilts-250Mm (10) , Cast Iron Dismantling Joints With Rubber Insertion & Nut Bilts-300Mm (12) , Cast Iron Dismantling Joints With Rubber Insertion & Nut Bilts-350Mm (14) , Cast Iron Dismantling Joints With Rubber Insertion & Nut Bilts-400Mm (16) , Cast Iron Dismantling Joints With Rubber Insertion & Nut Bilts-450Mm (18) , Cast Iron Dismantling Joints With Rubber Insertion & Nut Bilts-500Mm (20) , Cast Iron Dismantling Joints With Rubber Insertion & Nut Bilts-600Mm (24) , Cast Iron Dismantling Joints With Rubber Insertion & Nut Bilts-700Mm (28) , Cast Iron Dismantling Joints With Rubber Insertion & Nut Bilts-750Mm (30) , Cast Iron Dismantling Joints With Rubber Insertion & Nut Bilts-900Mm (36) , Cast Iron Dismantling Joints With Rubber Insertion & Nut Bilts-1000Mm , Cast Iron Cut-N-Repair Coupling (Long Barrel) With Rubber Insertion & Nut Bolts-80Mm (3) , Cast Iron Cut-N-Repair Coupling (Long Barrel) With Rubber Insertion & Nut Bolts-100Mm (4) , Cast Iron Cut-N-Repair Coupling (Long Barrel) With Rubber Insertion & Nut Bolts-125Mm (5) , Cast Iron Cut-N-Repair Coupling (Long Barrel) With Rubber Insertion & Nut Bolts-150Mm (6) , Cast Iron Cut-N-Repair Coupling (Long Barrel) With Rubber Insertion & Nut Bolts-200Mm (8) , Cast Iron Cut-N-Repair Coupling (Long Barrel) With Rubber Insertion & Nut Bolts-250Mm (10) , Cast Iron Cut-N-Repair Coupling (Long Barrel) With Rubber Insertion & Nut Bolts-300Mm (12) , Cast Iron Cut-N-Repair Coupling (Long Barrel) With Rubber Insertion & Nut Bolts-350Mm (14) , Cast Iron Cut-N-Repair Coupling (Long Barrel) With Rubber Insertion & Nut Bolts-400Mm (16) , Cast Iron Cut-N-Repair Coupling (Long Barrel) With Rubber Insertion & Nut Bolts-450Mm (18) , Cast Iron Cut-N-Repair Coupling (Long Barrel) With Rubber Insertion & Nut Bolts-500Mm (20) , Cast Iron Cut-N-Repair Coupling (Long Barrel) With Rubber Insertion & Nut Bolts-600Mm (24) , Cast Iron Cut-N-Repair Coupling (Long Barrel) With Rubber Insertion & Nut Bolts-700Mm (28) , Cast Iron Cut-N-Repair Coupling (Long Barrel) With Rubber Insertion & Nut Bolts-750Mm (30) , Cast Iron Mechanical Joint Bend Is:13382/9211¼°-80Mm (3) , Cast Iron Mechanical Joint Bend Is:13382/9211¼°-100Mm (4) , Cast Iron Mechanical Joint Bend Is:13382/9211¼°-150Mm (6) , Cast Iron Mechanical Joint Bend Is:13382/9211¼°-200Mm (8) , Cast Iron Mechanical Joint Bend Is:13382/9211¼°-250Mm (10) , Cast Iron Mechanical Joint Bend Is:13382/9211¼°-300Mm (12) , Cast Iron Mechanical Joint Bend Is:13382/9211¼°-350Mm (14) , Cast Iron Mechanical Joint Bend Is:13382/9211¼°-400Mm (16) , Cast Iron Mechanical Joint Bend Is:13382/9211¼°-450Mm (18) , Cast Iron Mechanical Joint Bend Is:13382/9211¼°-500Mm (20) , Cast Iron Mechanical Joint Bend Is:13382/9211¼°-600Mm (24) , Cast Iron Mechanical Joint Bend Is:13382/9211¼°-700Mm (28) , Cast Iron Mechanical Joint Bend Is:13382/9211¼°-750Mm (30) , Cast Iron Mechanical Joint Bend Is:13382/9211¼°-900Mm (36) , Cast Iron Mechanical Joint Bend Is:13382/9211¼°-1000Mm , Cast Iron Mechanical Joint Bend Is:13382/9222½°-80Mm (3) , Cast Iron Mechanical Joint Bend Is:13382/9222½°-100Mm (4) , Cast Iron Mechanical Joint Bend Is:13382/9222½°-150Mm (6) , Cast Iron Mechanical Joint Bend Is:13382/9222½°-200Mm (8) , Cast Iron Mechanical Joint Bend Is:13382/9222½°-250Mm (10) , Cast Iron Mechanical Joint Bend Is:13382/9222½°-300Mm (12) , Cast Iron Mechanical Joint Bend Is:13382/9222½°-350Mm (14) , Cast Iron Mechanical Joint Bend Is:13382/9222½°-400Mm (16) , Cast Iron Mechanical Joint Bend Is:13382/9222½°-450Mm (18) , Cast Iron Mechanical Joint Bend Is:13382/9222½°-500Mm (20) , Cast Iron Mechanical Joint Bend Is:13382/9222½°-600Mm (24) , Cast Iron Mechanical Joint Bend Is:13382/9222½°-700Mm (28) , Cast Iron Mechanical Joint Bend Is:13382/9222½°-750Mm (30) , Cast Iron Mechanical Joint Bend Is:13382/9222½°-900Mm (36) , Cast Iron Mechanical Joint Bend Is:13382/9222½°-1000Mm , Cast Iron Mechanical Joint Bend Is:13382/9245°-80Mm (3) , Cast Iron Mechanical Joint Bend Is:13382/9245°-100Mm (4) , Cast Iron Mechanical Joint Bend Is:13382/9245°-150Mm (6) , Cast Iron Mechanical Joint Bend Is:13382/9245°-200Mm (8) , Cast Iron Mechanical Joint Bend Is:13382/9245°-250Mm (10) , Cast Iron Mechanical Joint Bend Is:13382/9245°-300Mm (12) , Cast Iron Mechanical Joint Bend Is:13382/9245°-350Mm (14) , Cast Iron Mechanical Joint Bend Is:13382/9245°-400Mm (16) , Cast Iron Mechanical Joint Bend Is:13382/9245°-450Mm (18) , Cast Iron Mechanical Joint Bend Is:13382/9245°-500Mm (20) , Cast Iron Mechanical Joint Bend Is:13382/9245°-600Mm (24) , Cast Iron Mechanical Joint Bend Is:13382/9245°-700Mm (28) , Cast Iron Mechanical Joint Bend Is:13382/9245°-750Mm (30) , Cast Iron Mechanical Joint Bend Is:13382/9245°-900Mm (36) , Cast Iron Mechanical Joint Bend Is:13382/9245°-1000Mm , Cast Iron Mechanical Joint Bend Is:13382/9290°-80Mm (3) , Cast Iron Mechanical Joint Bend Is:13382/9290°-100Mm (4) , Cast Iron Mechanical Joint Bend Is:13382/9290°-150Mm (6) , Cast Iron Mechanical Joint Bend Is:13382/9290°-200Mm (8) , Cast Iron Mechanical Joint Bend Is:13382/9290°-250Mm (10) , Cast Iron Mechanical Joint Bend Is:13382/9290°-300Mm (12) , Cast Iron Mechanical Joint Bend Is:13382/9290°-350Mm (14) , Cast Iron Mechanical Joint Bend Is:13382/9290°-400Mm (16) , Cast Iron Mechanical Joint Bend Is:13382/9290°-450Mm (18) , Cast Iron Mechanical Joint Bend Is:13382/9290°-500Mm (20) , Cast Iron Mechanical Joint Bend Is:13382/9290°-600Mm (24) , Cast Iron Mechanical Joint Bend Is:13382/9290°-700Mm (28) , Cast Iron Mechanical Joint Bend Is:13382/9290°-750Mm (30) , Cast Iron Mechanical Joint Bend Is:13382/9290°-900Mm (36) , Cast Iron Mechanical Joint Bend Is:13382/9290°-1000Mm , Cast Iron Mechanical Joint Flange Spigot Is:13382/92 -80Mm (3) , Cast Iron Mechanical Joint Flange Spigot Is:13382/92 -100Mm (4) , Cast Iron Mechanical Joint Flange Spigot Is:13382/92 -150Mm (6) , Cast Iron Mechanical Joint Flange Spigot Is:13382/92 -200Mm (8) , Cast Iron Mechanical Joint Flange Spigot Is:13382/92 -250Mm (10) , Cast Iron Mechanical Joint Flange Spigot Is:13382/92 -300Mm (12) , Cast Iron Mechanical Joint Flange Spigot Is:13382/92 -350Mm (14) , Cast Iron Mechanical Joint Flange Spigot Is:13382/92 -400Mm (16) , Cast Iron Mechanical Joint Flange Spigot Is:13382/92 -450Mm (18) , Cast Iron Mechanical Joint Flange Spigot Is:13382/92 -500Mm (20) , Cast Iron Mechanical Joint Flange Spigot Is:13382/92 -600Mm (24) , Cast Iron Mechanical Joint Flange Spigot Is:13382/92 -700Mm (28) , Cast Iron Mechanical Joint Flange Spigot Is:13382/92 -750Mm (30) , Cast Iron Mechanical Joint Flange Spigot Is:13382/92 -900Mm (36) , Cast Iron Mechanical Joint Flange Spigot Is:13382/92 -1000Mm , Cast Iron Mechanical Joint Reducer Is:13382/92 -200X150mm (8X6) , Cast Iron Mechanical Joint Reducer Is:13382/92 -250X200mm (10X8) , Cast Iron Mechanical Joint Reducer Is:13382/92 -300X250mm (12X10) , Cast Iron Mechanical Joint Reducer Is:13382/92 -350X250mm (14X10) , Cast Iron Mechanical Joint Reducer Is:13382/92 -400X300mm (16X12) , Cast Iron Mechanical Joint Reducer Is:13382/92 -450X300mm (18X12) , Cast Iron Mechanical Joint Reducer Is:13382/92 -500X400mm (20X16) , Cast Iron Mechanical Joint Reducer Is:13382/92 -600X300mm (24X12) , Cast Iron Mechanical Joint Reducer Is:13382/92 -700X300mm (28X12) , Cast Iron Mechanical Joint Reducer Is:13382/92 -750X300mm (30X12) , Cast Iron Mechanical Joint Equal Tee Is:13382/92 -80Mm (3) , Cast Iron Mechanical Joint Equal Tee Is:13382/92 -100Mm (4) , Cast Iron Mechanical Joint Equal Tee Is:13382/92 -150Mm (6) , Cast Iron Mechanical Joint Equal Tee Is:13382/92 -200Mm (8) , Cast Iron Mechanical Joint Equal Tee Is:13382/92 -250Mm (10) , Cast Iron Mechanical Joint Equal Tee Is:13382/92 -300Mm (12) , Cast Iron Mechanical Joint Equal Tee Is:13382/92 -350Mm (14) , Cast Iron Mechanical Joint Equal Tee Is:13382/92 -400Mm (16) , Cast Iron Mechanical Joint Equal Tee Is:13382/92 -450Mm (18) , Cast Iron Mechanical Joint Equal Tee Is:13382/92 -500Mm (20) , Cast Iron Mechanical Joint Equal Tee Is:13382/92 -600Mm (24) , Cast Iron Mechanical Joint Equal Tee Is:13382/92 -700Mm (28) , Cast Iron Mechanical Joint Equal Tee Is:13382/92 -750Mm (30) , Cast Iron Mechanical Joint Equal Tee Is:13382/92 -900Mm (36) , Cast Iron Mechanical Joint Equal Tee Is:13382/92 -1000Mm , Cast Iron Sluice Valve As Per Is 14846/2000 Kirloskar Or Upadhaya-50Mm (2) , Cast Iron Sluice Valve As Per Is 14846/2000 Kirloskar Or Upadhaya-80Mm (3) , Cast Iron Sluice Valve As Per Is 14846/2000 Kirloskar Or Upadhaya-100Mm (4) , Cast Iron Sluice Valve As Per Is 14846/2000 Kirloskar Or Upadhaya-150Mm (6) , Cast Iron Sluice Valve As Per Is 14846/2000 Kirloskar Or Upadhaya-200Mm (8) , Cast Iron Sluice Valve As Per Is 14846/2000 Kirloskar Or Upadhaya-250Mm (10) , Cast Iron Sluice Valve As Per Is 14846/2000 Kirloskar Or Upadhaya-300Mm (12) , Cast Iron Sluice Valve As Per Is 14846/2000 Kirloskar Or Upadhaya-350Mm (14) , Cast Iron Sluice Valve As Per Is 14846/2000 Kirloskar Or Upadhaya-400Mm (16) , Cast Iron Sluice Valve As Per Is 14846/2000 Kirloskar Or Upadhaya-450Mm (18) , Cast Iron Sluice Valve As Per Is 14846/2000 Kirloskar Or Upadhaya-500Mm (20) , Cast Iron Sluice Valve As Per Is 14846/2000 Kirloskar Or Upadhaya-600Mm (24) , Cast Iron Sluice Valve As Per Is 14846/2000 Kirloskar Or Upadhaya-700Mm (28) , Cast Iron Sluice Valve As Per Is 14846/2000 Kirloskar Or Upadhaya-750Mm (30) , Cast Iron Sluice Valve As Per Is 14846/2000 Kirloskar Or Upadhaya-900Mm (36) , Cast Iron Sluice Valve As Per Is 14846/2000 Kirloskar Or Upadhaya-1000Mm , Double Action Air Valve Cast Iron Is. 14845/2000-50Mm (2) , Double Action Air Valve Cast Iron Is. 14845/2000-80Mm (3) , Double Action Air Valve Cast Iron Is. 14845/2000-110Mm (4) , Double Action Air Valve Cast Iron Is. 14845/2000-150Mm (6) , Double Action Air Valve Cast Iron Is. 14845/2000-200Mm (8) , Castic Soda- , Cotton Waste- , Wire Rope 3 Mm For Level Gauge- , Wire Rope Pulley For Leval Guage- , Weight For Level Gauge- , Float Valve With Ball-1/2 , Float Valve With Ball-1 , Water Meter Flange Type Industrial C.I. Body Class B Removable Mechanism Type Iso Certified MakeChambal Or Dashmesh-2 , Water Meter Flange Type Industrial C.I. Body Class B Removable Mechanism Type Iso Certified MakeChambal Or Dashmesh-3 , Water Meter Flange Type Industrial C.I. Body Class B Removable Mechanism Type Iso Certified MakeChambal Or Dashmesh-4 , Water Meter Flange Type Industrial C.I. Body Class B Removable Mechanism Type Iso Certified MakeChambal Or Dashmesh-6 , Water Meter Flange Type Industrial C.I. Body Class B Removable Mechanism Type Iso Certified MakeChambal Or Dashmesh-8 , Water Meter Flange Type Industrial C.I. Body Class B Removable Mechanism Type Iso Certified MakeChambal Or Dashmesh-10 , Water Meter Flange Type Industrial C.I. Body Class B Removable Mechanism Type Iso Certified MakeChambal Or Dashmesh-12 , Water Meter Single Jet Type Magnetic Drive With Plastic Gear Is 779 -Class B Powder Conating Make Chambal-1/2 , Water Meter Multi Jet Magnetic Drive Is 779 -Class B Powder Conating Make Chambal-1/2 , Water Meter Multi Jet Magnetic Drive Is 779 -Class B Powder Conating Make Chambal-3/4 , Water Meter Multi Jet Magnetic Drive Is 779 -Class B Powder Conating Make Chambal-1 , Water Meter Multi Jet Magnetic Drive Is 779 -Class B Powder Conating Make Chambal-1-1/2 , Water Meter Multi Jet Magnetic Drive Is 779 -Class B Powder Conating Make Chambal-2 , Open Well Submersible Pump Set Isi Texmo, Kirloskar Or Equilent-0.5 Hp , Open Well Submersible Pump Set Isi Texmo, Kirloskar Or Equilent-1.0 Hp , Open Well Submersible Pump Set Isi Texmo, Kirloskar Or Equilent-1.5 Hp , Open Well Submersible Pump Set Isi Texmo, Kirloskar Or Equilent-2.0 Hp , Centrifugal Monoblock Pump Sets Isi Sharp Texmo, Kirloskar-0.5 Hp , Centrifugal Monoblock Pump Sets Isi Sharp Texmo, Kirloskar-1.0 Hp , Centrifugal Monoblock Pump Sets Isi Sharp Texmo, Kirloskar-1.5 Hp , Centrifugal Monoblock Pump Sets Isi Sharp Texmo, Kirloskar-2.0 Hp , Centrifugal Monoblock Pump Sets Isi Sharp Texmo, Kirloskar-3.0 Hp , Ball Valves Cast Iron H/D-1/2 , Ball Valves Cast Iron H/D-1 , Ball Valves Cast Iron H/D-1-1/2 , Ball Valves Cast Iron H/D-2 , Ball Valves Cast Iron H/D-3 , Spare Ball For Air Valve-80 Mm (3) , Spare Ball For Air Valve-100 Mm (4) , Spare Ball For Air Valve-150 Mm (6) , Spare Ball For Air Valve-200 Mm (8) , Fire Hose Pipe 2½-15 Mtr Roll Isi Or Equilent , Fire Hose Pipe 2½-30 Mtr Roll Isi Or Equilent , Allsize Elenkey (Set)- , L.T. Copper Bus Bar Of 33/0.43 Kv Transformer 17X65mm X10 Mm- , 10Mm Heavy Duty Drill 550W 1250Rpm1.8 Kg- , Z Clamp For 33 Kv Bus Bar & A.B. Switch- , 180Mm Speed Angle Grinder 2000W 5800 Rpm 6.9 Kg- , Pressure Gauge (0 To 10 Kg)- , Pressure Gauge Glycerin Filled (0 To 10 Kg)- , Hand Wheels For Various Valve- , Grp Material Mekp - , Ortho Resin - , Cobalt- , Contactor Siemens 3Tf-50- , Mccb 100 Amps L&T- , Pump Shaftfor 300Hp Pump- , Phase Failure Relay Vspd-3,- , Phase Failure Relay Vspd-2- , Hexagonal/Bihexagonal Square Drive Set.- , Chain Wrench 300Mm- , Stud With Nut-16X80 , Stud With Nut-21X80 , Cir Clip(Big)80Mm- , Tvs Nut Bolt-15X80 , Tvs Nut Bolt-12X80 , Ball Bearing 7322 Skf- , Contactor Mnx-32 L&T- , Et-100 Timer- , Ball Bearing 319-M (Fag)- , Auto Transformer Motor Oil Ep-90 Servo- , Cable Flat Submersible25sq Mm- , Switch Type Ffo, 415V-63Amp , Switch Type Ffo, 415V-32Amp , Rechargeable Torch 12 Volts, Dry Battery Supper Quality- , Compressor Oil- , Grear Oil- , Putti Gloves - , Chlorine Copper Pipe With Holder - , Shoes /Long Boot- , Helmet- , Factor Meter 415 Volt- , Teflon Tap- , Motor Pump Set 3Hp - , Motor 3Hp (Kirloskar Make)- , Submersible Motor Pump Set 25Hp Isi - , Fiber Bush With Stud And Four Nut & Washer - , Fix (Goti) Spanner Complete Set - 8 To 32 No- , Bakelite Fuse Holders L&T, 415 V-20Amp , Bakelite Fuse Holders L&T, 415 V-32Amp , Bakelite Fuse Holders L&T, 415 V-63Amp , Bakelite Fuse Holders L&T, 415 V-100Amp , Mcb -10 Amp , Mcb -16 Amp , Mcb -32 Amp , Mcb -40 Amp , Mcb -63 Amp , Mcb ( Two Pole Way) -32 Amp , Mcb ( Two Pole Way) -63 Amp , Mcb (Four Pole Way)-32 Amp , Mcb (Four Pole Way)-63 Amp , Sfu Unit-400Amps , Sfu Unit-200Amps , Sfu Unit-32Amps , Hrc Fuse-400Amps , Hrc Fuse-200Amps , Hrc Fuse-32Amps , Distribution Board ( Bus Bar ) T.P.N. Single Door Steel 4 Way Rating 200Amp- , Contactor Abb -A145-30 , Contactor Abb -A260-30 , Contactor Abb -A75-30 , Contactor Abb -A95-30 , Contactor Abb -A110-30 , Contactor Abb -A16-30-10 , Copper Cable -50 Sq.Mm , Copper Cable -35 Sq.Mm , Control Wiring 1.5 Sq.Mm- , Conductor 2.5 Sq.Mm- , Mpr D2 240 Vac (Motor Protection Relay)- , Current Converter 2-5 Amps (Range)- , Timer Ct-Yde 240 V Ac- , Overload Relay Ta 110 Du 60-90A- , Ct-Yde Time 240 Vac For (Vacuum Pump)- , 250A Tpn Mcb - , Tpn Mcb 250A- , Acetic Acid Glacial 100% (Aldehyde Free) Gr- , Acetone For Analysis Emparta® Acs- , Ammonium Carbonate Gr- , Ammonium Hydrogen Difluoride Purified (Ammonium Difluoride)- , Ammonium Monovanadate Gr- , Barium Carbonate Gr- , Buffer Solution Ph -Ph 2.00 , Buffer Solution Ph -Ph 4.00 , Buffer Solution Ph -Ph 7.00 , Buffer Solution Ph -Ph 9.00 , Calcium Hydroxide Gr- , Chloramine T Trihydrate Gr- , Chloroform Emplura®- , Erichrome Black T (C.I. No. 14645, S.No. 241) Indicator- , Ethyl Chloroformate For Synthesis- , Ferroin Indicator Solution- , Hydrazinium Sulfate Gr- , Hydroxylammonium Chloriede Gr- , Lactic Acid Min. 88% Gr- , Magnesium Carbonate Light Pure - , Methyl Acetate For Synthesis- , Methyl Orange ( C.I. No. 13025 S.No. 176) Indicator- , Methyl Red ( C.I. No. 13020 S. No. 250) Indicator- , 1- Naphthol Gr- , 1,10-Phenanthroline ( Monohydrate) Gr And Redox Indicator- , Phenol Red Indicatorph 6.8 - 8.4- , Potassium Acetate Gr- , Potassium Dichromate Emplura® - , Potassium Fluoride For Analysis Emparta® Acs - , Di- Potassium Hydrogen Phosphate Anhydrous For Analysis Emparta®Acs- , Potassium Iodide For Analysis Emparta® Acs- , Pyridine For Analysis Emparta®Acs- , Pyridine For Analysis Emsure® Acs Reag. Ph.Eur.- , Silver Diethyldithiocarbamate Extra Pure- , Silver Sulfate Emplura®- , Sodium Azide- , Sodium Azide For Analysis Emparta® Acs- , Sodium Chloride Gr For Analysis Acs, Iso Reag.Ph Eur.- , Sodium Dichromate Dihydrate Emplura®- , Sodium Dihydrogen Phosphate Dihydrate For Analysis Emsure®Reag. Ph Eur- , Sodium Fluoride For Analylsis Emparta® Acs- , Sodium Molybdate Pure Emplura®- , Di- Sodium Tatrate Dihydrate Gr- , Sulfanilic Acid For Analysis Emparta® Acs- , Sulfanilic Acid Gr For Analysis Acs, Reag. Ph. Eur- , 5-Sulfosalicylic Acid Exra Pure- , Thymol Blue Indicator- , Zinc Powder Pure- , Ammonium Dichromate Cryst. Pure.- , Pvc.Float Valve ½ , Pvc.Float Valve 1 , Pvc.Red.Bush ¾ X ½ , Pvc.Red.Bush 1 ¼ X ½ , Pvc.Red.Bush 1 ¼ X 1 , Pvc.Red.Bush 1 ½ X ½ , Pvc.Red.Bush 1 ½ X ¾ , Pvc.Red.Bush 1 ½ X 1 , Pvc.Red.Bush 1 X ½ , Pvc.Red.Bush 1 X ¾ , Pvc.Red.Elbow 1 X ½ , Pvc.Red.Elbow 1 X ¾ , Pvc.Red.Socket ¾ X ½ , Pvc.Red.Tee ¾ X ½ , Pvc.Red.Tee 1 X ¾ , Pvc.Plumb Pipe ½ Wh S/80 , Pvc.Plumb Pipe ¾ Wh S/80 , Pvc.Plumb Pipe 1 Wh S/80 , Pvc.Plumb Pipe 1¼ Wh S/80 , Pvc.Plumb Pipe 1½ Wh S/80 , Pvc.Plumb Pipe 2 Wh S/80 , Pvc.Sh80 Compact B-Valve ½ , Pvc.Sh80 Compact B-Valve ¾ , Pvc.Sh80 Compact B-Valve 1 , Pvc.Sh80 Compact B-Valve 1¼ , Pvc.Sh80 Compact B-Valve 1½ , Pvc.Sh80 Compact B-Valve 2 , Pvc.Sh80 R.Bush 1¼X1 , Pvc.Sh80 R.Bush 1½X1 , Pvc.Sh80 R.Socket ¾X½ , Pvc.Sh80 R.Socket 1 ¼X½ , Pvc.Sh80 R.Socket 1 ¼X¾ , Pvc.Sh80 R.Socket 1 ¼X1 , Pvc.Sh80 R.Socket 1 ½X½ , Pvc.Sh80 R.Socket 1 ½X¾ , Pvc.Sh80 R.Socket 1 ½X1 , Pvc.Sh80 R.Socket 1 ½X1¼ , Pvc.Sh80 R.Socket 1X½ , Pvc.Sh80 R.Socket 1X¾ , Pvc.Sh80 R.Socket 2X½ , Pvc.Sh80 R.Socket 2X¾ , Pvc.Sh80 R.Socket 2X1 ¼ , Pvc.Sh80 R.Socket 2X1 ½ , Pvc.Sh80 R.Socket 2X1 , Pvc.Sh80 R.Elbow ¾X½ , Pvc.Sh80 R.Elbow 1X½ , Pvc.Sh80 R.Elbow 1X¾ , Pvc.Sh80 R.Elbow 1¼ X 1 , Pvc.Sh80 R.Tee ¾X½ , Pvc.Sh80 R.Tee 1X½ , Pvc.Sh80 R.Tee 1X¾ , Pvc.Sh80 Tank Nipple ½ , Pvc.Sh80 Tank Nipple ¾ , Pvc.Sh80 Tank Nipple 1 , Pvc.Sh80 Tank Nipple 1¼ , Pvc.Sh80 Tank Nipple 1½ , Pvc.Sh80 Union Assy ½ , Pvc.Sh80 Union Assy ¾ , Pvc.Sh80 Union Assy 1 , Pvc.Sh80 Union Assy 1 ¼ , Pvc.Sh80 Union Assy 1 ½ , Pvc.Sh80 Union Assy 2 , Pvc.Sh80 S/Union B-Valve ½ , Pvc.Sh80 S/Union B-Valve ¾ , Pvc.Sh80 S/Union B-Valve 1 , Pvc.Sh80 S/Union B-Valve 1¼ , Pvc.Sh80 S/Union B-Valve 1½ , Pvc.Sh80 S/Union B-Valve 2 , Pvc.Sh80 Wh.Coupler ½ , Pvc.Sh80 Wh.Coupler ¾ , Pvc.Sh80 Wh.Coupler 1 , Pvc.Sh80 Wh.Coupler 1 ¼ , Pvc.Sh80 Wh.Coupler 1 ½ , Pvc.Sh80 Wh.Coupler 2 , Pvc.Sh80 Wh.Elbow ½ , Pvc.Sh80 Wh.Elbow ¾ , Pvc.Sh80 Wh.Elbow 1 , Pvc.Sh80 Wh.Elbow 1 ¼ , Pvc.Sh80 Wh.Elbow 1 ½ , Pvc.Sh80 Wh.Elbow 2 , Pvc.Sh80 Wh.Elbow Br.Ft. ½ , Pvc.Sh80 Wh.Elbow Br.Ft. ¾ , Pvc.Sh80 Wh.Elbow Br.Ft. 1 , Pvc.Sh80 Wh.End Cap ½ , Pvc.Sh80 Wh.End Cap ¾ , Pvc.Sh80 Wh.End Cap 1 , Pvc.Sh80 Wh.End Cap 1 ¼ , Pvc.Sh80 Wh.End Cap 1 ½ , Pvc.Sh80 Wh.End Cap 2 , Pvc.Sh80 Wh.Fta 1 ¼ , Pvc.Sh80 Wh.Fta 1 ½ , Pvc.Sh80 Wh.Fta 2 , Pvc.Sh80 Wh.Fta Br.Ft. ½ , Pvc.Sh80 Wh.Fta Br.Ft. ¾ , Pvc.Sh80 Wh.Fta Br.Ft. 1 , Pvc.Sh80 Wh.Mta 1 ¼ , Pvc.Sh80 Wh.Mta 1 ½ , Pvc.Sh80 Wh.Mta 2 , Pvc.Sh80 Wh.Mta Br.Ft. ½ , Pvc.Sh80 Wh.Mta Br.Ft. ¾ , Pvc.Sh80 Wh.Mta Br.Ft. 1 , Pvc.Sh80 Wh.Tee ½ , Pvc.Sh80 Wh.Tee ¾ , Pvc.Sh80 Wh.Tee 1 , Pvc.Sh80 Wh.Tee 1 ¼ , Pvc.Sh80 Wh.Tee 1 ½ , Pvc.Sh80 Wh.Tee 2 , Pvc.Sh80 Wh.Tee Br.Ft. ½ , Pvc.Sh80 Wh.Tee Br.Ft. ¾ , Pvc.Sh80 Wh.Tee Br.Ft. 1 , Pvc.Solvent 1 Ltr , Level /Pressure Indicatormeter -Commander 150/240V A/Cabb , (Draw Out) Lt Panal-10A Tpn , (Draw Out) Lt Panal-125 A /Mcb , (Draw Out) Lt Panal-165 A /Mcb , (Draw Out) Lt Panal-20 A/Tpn , (Draw Out) Lt Panal-200 A /Mcb , (Draw Out) Lt Panal-32 A /Mcb , (Draw Out) Lt Panal-32 A/Tpn , (Draw Out) Lt Panal-400 A /Mcb , (Draw Out) Lt Panal-63 4 A /Mcb , (Draw Out) Lt Panal-63 A /Elcb , (Draw Out) Lt Panal-Amp Meter , (Draw Out) Lt Panal-Aux.Condectore 16 A /Ac Voltc , (Draw Out) Lt Panal-Aux.Condectore 32 A /Ac Voltc&S , (Draw Out) Lt Panal-Aux.Condectore 63 A /Ac Voltc&S , (Draw Out) Lt Panal-Over Current Relaac Volt C&S , (Draw Out) Lt Panal-Relay /0.1-1.0Minillec , (Draw Out) Lt Panal-Volt Metre , 1300 Mm Dia Grp Bends - , 1300 Mm Dia Grp Coupling - , 33 Kv Current Transformer-Is 2705 150 A Kalpa , 33 Kv Current Transformer Is 2705 75 A-Primary Therminalkalpa , 33 Kv Potential Transformer -36Opt ,33Kv/Rt3kalpa , 34 Kv Current Transformer Is 2705 75 A-Primary Connection Chamber , 35 Kv Current Transformer Is 2705 75 A-Flange Type Insulator , 36 Kv Current Transformer Is 2705 75 A-Matalic Expension Below , 37 Kv Current Transformer Is 2705 75 A-Secondary Therminal Box , 38 Kv Current Transformer Is 2705 75 A-Dome Cover , Air Blowercap.220 Ltr.120 Hn-Pressure Guage Equavellent , Air Blowercap.220 Ltr.120 Hn-Pully Newelgi , Air Blowercap.220 Ltr.120 Hn-Safety Valve Equavellent , Air Blowercap.220 Ltr.120 Hn-V-Belt Equavellent , Air Blowercap.3450M3/Hr Head 3.5 Mwc -Pully Newkayinternational , Air Blowercap.3450M3/Hr Head 3.5 Mwc -V-Belt (Spc2800) , Air Blowercap.3450M3/Hr Head 3.5 Mwc -Pressure Guage , Air Blowercap.3450M3/Hrhead 3.5 Mwc -Safety Valve , Area Lighting(Sodium Vapour Lamp) Complete Fitting) -100 W , Area Lighting(Sodium Vapour Lamp) Complete Fitting) -50 W Chowk , Area Lighting(Sodium Vapour Lamp) Complete Fitting) -50 W Ignitor , Area Lighting(Sodium Vapour Lamp) Complete Fitting) -50 W Lamp , Area Lighting(Sodium Vapour Lamp) Complete Fitting) -150 W , A.C.B. 415 Volt-1250 A C&S , A.C.B. 415 Volt-800 A , Air Valve 150 Mm-Newsarker , Air Valve 200 Mm-Newsarker , Annunciator-Audio Visual Micro Processerkrypton , Ball Bearing 22214 Fag - , Ball Bearing 22214 Fag -15 Hp , Ball Bearing 22214 Fag -25 Hp , Ball Bearing 22214 Fag -Ball Bearing For 225 Hp , Capacitor -3.3 Kv 150 Kvarepcose/Equavellent , Capacitor -3.3 Kv 156 Kvarmadhav , Capacitor -415 V 100 Kvarepcose/Equavellent , Capacitor -415 V 68 Kvarepcose/Equavellent , Capacitor -60 Amp Hrc Fuse (3.3 Kva) , Capacitor -Bus Bar Support Insulator , Chemicals-1,10- Phenanthroline , Chemicals-1-10 Phenopthlene , Chemicals-42 No. Filter Paper , Chemicals-43 Whatstman Filter Paper , Chemicals-5-Sulfosalicylic Acid , Chemicals-Acetic Acid Glacial , Chemicals-Alizarine Red 5 , Chemicals-Aluminium Ammonium , Chemicals-Amino Solution , Chemicals-Ammnium Buffer Solution , Chemicals-Ammonia Solution , Chemicals-Ammonium Acetate , Chemicals-Ammonium Acetete , Chemicals-Ammonium Buffer Solution , Chemicals-Ammonium Chloride , Chemicals-Ammonium Hydoxide , Chemicals-Ammonium Molibdate , Chemicals-Arochrome Black (T) , Chemicals-Barium Chloride , Chemicals-Barrium Chloride , Chemicals-Calcium Chloride , Chemicals-Ebt (Eriochrome Black-T) , Chemicals-Edta Powder , Chemicals-Ethanol , Chemicals-Methenol , Chemicals-Ethylenediaminetetraacetic , Chemicals-Glycerol , Chemicals-Haxamine Gr , Chemicals-Hexamethylene Tetramine , Chemicals-Hydrochloric Acid Concentrated , Chemicals-Hydroxyl Amine Hydrochloride , Chemicals-M. Stepro Cocus Agar , Chemicals-M/7 Fc Agar , Chemicals-Methanol , Chemicals-Methyl Red , Chemicals-Mnso4 , Chemicals-Nitric Acid , Chemicals-Nitric Acid Concentrated , Chemicals-Nuturine Ped , Chemicals-Petridish , Chemicals-Phenol Di Sulphonic Acid , Chemicals-Phenopthlene Indicator , Chemicals-Potassium Chromate , Chemicals-Potassium Sodium Tartrate , Chemicals-Silver Nitrate , Chemicals-Sodium Acetate , Chemicals-Sodium Borohydride , Chemicals-Sodium Hydroxide , Chemicals-Sodium Thiosulphate , Chemicals-Stanous Chloride , Chemicals-Starch , Chemicals-Starch Soluble Extra Pure , Chemicals-Sulfanilic Acid Gr , Chemicals-Sulphuric Acid 98% , Chemicals-Tarsan Membrane , Chemicals-Toluene , Chemicals-Unabsorbant Cotton , Chemicals-Zinc Sulphate , Chemicals-Zirconil Oxy Chliride , Chlorine System- Gas Regulator Equavellent , Chlorine System- Tonner Roller Equavellent , Chlorine System-Caustic Pump Mod.160Ctequavellent , Chlorine System-Cl2 Gas Filter Equavellent , Chlorine System-Cl2 Leakage Detector Equavellent , Chlorine System-Copper Tube Equavellent , Chlorine System-Glass Froroted Steel Cabnet Equavellent , Chlorine System-Measuring Glass(10 Kg)Equavellent , Chlorine System-Measuring Glass(15 Kg)Equavellent , Chlorine System-Pp Diaphram Valve 40 Mm Equavellent , Chlorine System-Pp Diaphram Valve50 Mm Equavellent , Chlorine System-Vacum Cl2 Cvr 10Ejector Typ Equavellent , Chlorine System-Valve With Actuator Equavellent , Chlorine System -Centrifugal Booster Pump 4 Mq At 40 Mwc Head , Chlorine System -Chlorine Filter , Chlorine System -Chlorine Pressure Guage , Chlorine System -Copper Tube - 3 Mt , Chlorine System -First Aid Box , Chlorine System -First Aid Chart , Chlorine System -Headerline Valve , Chlorine System -Headerline With Holding , Chlorine System -Leakage Detector , Chlorine System -Load Indicator Of 2 Ton Capacity , Chlorine System -Oxygen Kit , Chlorine System -Tonner Isolation Valve , Chlorine System -Tonner Rollers , Chlorine System -Vaccum Feed Chlorinator Of Capacity 10 Kg , Chlorine System -Y-Stainer , Clairifloculator-Bridge Drive Bearing Metal Fabricator , Clairifloculator-Bridge Padal Bearing , Clairifloculator-Current Collecter , Clairifloculator-Flocolator Gear Box (Readycon) , Clairifloculator-Scraper Blade &Rubber , Clear Water Chlorine Meter - , Clear Water Ph Meter - , Clear Water Turbidity Meter - , Cobalt - , Conductivity Type Levelswitch-Active Electrodelevcon , Conductivity Type Levelswitch-Probe Head Incloser , Conductivity Type Levelswitch-Refrense Electrode , Conductor Cable 12 Mm- , Control Panal-Add On Block No,Nc,L&T , Control Panal-Annuncitore 21 240V A/C Procon , Control Panal-Auxiliary Contectore 2No,2Ncl&T , Control Panal-Closing Coil 110V D/C , Control Panal-Hooter 96X96 Sqmm. 240V A/Cvaishno , Control Panal-Miniture Circuit Breaker Legard , Control Panal-Selectore Swith 2 Pole ,2Waykaycee , D Sludge Motor Pump 40 Kw -Cable Grommetneoprine , D Sludge Motor Pump 40 Kw -Impeller , D Sludge Motor Pump 40 Kw -Lower Ball Bearing , D Sludge Motor Pump 40 Kw -Rotor Shaft , D Sludge Motor Pump 40 Kw -Upper Ball Bearing , D Sludge Motor Pump 40 Kw -Upper Bearing Cover , Dc Battery Charger-110V Dcdb , Dc Battery Charger-Aux. Card , Dc Battery Charger-Batteryhbl , Dc Battery Charger-Boost Relays , Dc Battery Charger-Charger & Battery Shunt , Dc Battery Charger-Choke , Dc Battery Charger-Control Card , Dc Battery Charger-Control Ckt & V. Meters Fuses/Terminals , Dc Battery Charger-Control Transformer , Dc Battery Charger-Diode , Dc Battery Charger-F.W. Blocking Diodes , Dc Battery Charger-Filter Capacitor , Dc Battery Charger-Hardware , Dc Battery Charger-I/P Volt Meter Select Switch , Dc Battery Charger-Mother Board , Dc Battery Charger-Pcb , Dc Battery Charger-Power Supply Card , Dc Battery Charger-R C Card , Dc Battery Charger-Terminal Strip , Dc Battery Charger-Time Delay Card , Distance Piece 1000 Mm Dia -Joint Rubber Gaskit , Distance Piece 1000 Mm Dia -New Precise Engg. , Distance Piece 500 Mm Dia -Joint Rubber Gaskit , Distance Piece 500 Mm Dia -New Nandamanuf , Distance Piece 600 Mm Dia -Joint Rubber Gaskit , Distance Piece 600 Mm Dia -New Precise Engg. , Distance Piece 700 Mm Dia -Joint Rubber Gaskit Nandamanuf , Distance Piece 700 Mm Dia -New , Filter Media-A)Effective Size Filter Sand , Filter Media-B)Uniformity Coefficient Sand , Flow Meter-600 Ma Diasiemens , Forced Water Lubrication System-Bearing , Forced Water Lubrication System-Bearing Bracket , Forced Water Lubrication System-Bearing Cover Packing , Forced Water Lubrication System-Casing , Forced Water Lubrication System-Gasket For Casing , Forced Water Lubrication System-Impeller , Forced Water Lubrication System-Mediadelta Project , Forced Water Lubrication System-Sealing , Forced Water Lubrication System-Shaft Sleve , Forced Water Lubrication System-Stuffing Box , Forced Water Lubrication System-Turbidity Inlet , Gi Cable Tray-150 Mm , Gi Cable Tray-200 Mm , Gi Cable Tray-300 Mm , Gi Cable Tray-450 Mm , Gi Cable Tray-50 Mm , Glass Fibre Met - , H.T. Panal-Amp Metr. Meco , H.T. Panal-B24/110V /125 V Dcessun Relay , H.T. Panal-Current Tranformer 3.6/10Kvinsutech Industries , H.T. Panal-Earth Rela /0.10.5 Essun Relay , H.T. Panal-Kwh 10-120 Cohzerv , H.T. Panal-Lo Volt/ Hi Volt Essun Relay , H.T. Panal-Rho3 1A/5A 110 V Dcessun Relay , H.T. Panal-Volt Metrdip , H.T. Panal-Xr315 112V Dc Essun Relay , Hand Wheels For Various Valves - , Horizontal Centrifugal Pump(3.7 Kw) -Impeller Becon Or Equavellent , Horizontal Centrifugal Pump(3.7 Kw) -Shaft Bearing Becon Or Equavellent , Horizontal Centrifugal Pump (1.1 Kw) -Impeller Becon Or Equavellent , Horizontal Centrifugal Pump (1.1 Kw) -Shaft Bearing Becon Or Equavellent , Horizontal Centrifugal Pump (1.5 Kw) -Impeller Becon Or Equavellent , Horizontal Centrifugal Pump (1.5 Kw) -Shaft Bearing Becon Or Equavellent , Horizontal Centrifugal Pump (2.2 Kw) -Impeller Becon Or Equavellent , Horizontal Centrifugal Pump (2.2 Kw) -Shaft Bearing Becon Or Equavellent , Horizontal Centrifugal Pump (5.5 Kw) -Impeller Becon Or Equavellent , Horizontal Centrifugal Pump (5.5 Kw) -Shaft Bearing Becon Or Equavellent , Horizontal Centrifugal Pump 15 Mt Head 270 M3/Hr ( 22 Kw) -Impeller S.S./Equavellent , Horizontal Centrifugal Pump 15 Mt Head 270 M3/Hr ( 22 Kw) -Shaft Bearing Kirlosker Or Equavellent , Horizontal Centrifugal Pump 40Mt Head (7.5 Kw) -Impeller Becon Or Equavellent , Horizontal Centrifugal Pump 40Mt Head (7.5 Kw) -Shaft Bearing Becon Or Equavellent , Horizontal Centrifugal Pump 45 Mt Head 15 Kw) -Impeller Becon Or Equavellent , Horizontal Centrifugal Pump 45 Mt Head 15 Kw) -Shaft Bearing Becon Or Equavellent , Hrcfuse 415 V L&T -10 Amp , Hrcfuse 415 V L&T -100 Amp , Hrcfuse 415 V L&T -12 Amp , Hrcfuse 415 V L&T -150 Amp , Hrcfuse 415 V L&T -16 Amp , Hrcfuse 415 V L&T -20 Amp , Hrcfuse 415 V L&T -200 Amp , Hrcfuse 415 V L&T -25 Amp , Hrcfuse 415 V L&T -250 Amp , Hrcfuse 415 V L&T -32 Amp , Hrcfuse 415 V L&T -400 Amp , Hrcfuse 415 V L&T -50 Amp , Hrcfuse 415 V L&T -6 Amp , Hrcfuse 415 V L&T -63 Amp , Hrcfuse 415 V L&T -70 Amp , Hrcfuse 415 V L&T -8 Amp , Hrcfuse 415 V L&T -80 Amp , Impellers For - 215 Hp Centrifugal Pump -15 Hp , Impellers For - 215 Hp Centrifugal Pump -25 Hp , Indoor V.C.B. 3.6 Kva 800 A -Counter , Indoor V.C.B. 3.6 Kva 800 A -Coupling , Indoor V.C.B. 3.6 Kva 800 A -Diving Roller For Shutter , Indoor V.C.B. 3.6 Kva 800 A -Insulating Barrier , Indoor V.C.B. 3.6 Kva 800 A -Insulating Stud Assy , Indoor V.C.B. 3.6 Kva 800 A -Interlock Lever , Indoor V.C.B. 3.6 Kva 800 A -Lower Bush Conductor , Indoor V.C.B. 3.6 Kva 800 A -Primary Disconnects , Indoor V.C.B. 3.6 Kva 800 A -Socket For Multipin Plug , Indoor V.C.B. 3.6 Kva 800 A -Upper Bush Conductor , Indoor V.C.B. 3.6 Kva 800 A -Vaccum Interupters , Indoor V.C.B. 3.6 Kva 800 A -Vk 10J13jyoti , Instruments -Conductivity & Tds Meter , Instruments -Distillation Apparatus 4 Lt Capacity , Instruments -Hot Plate , Instruments -Nutrine Pad , Instruments -Petridishes50/17 Mm , Instruments -Ph Meter , Instruments -Spectophotometer , Instruments -Tarsan Membrane Assembly , Instruments -Tubidity Meter , Instruments -Vaccume Pump , Isoliating Switchhorizental Upright Solidcore Insulator Double Break Rotating Type -100 Amp, 33000 Volttopline Switchgear Pvt.Ltd , Lifting Crane10 Ton -Brake Liningrewa Or Equavellent , Lifting Crane10 Ton -Coil Breack Solenoid Rewa Or Equavellent , Lifting Crane10 Ton -Level Switch Rewa Or Equavellent , Lifting Crane10 Ton -Wire Rope Rewa Or Equavellent , Lifting Crane2 Ton -Brake Liningrewa Or Equavellent , Lifting Crane2 Ton -Coil Breack Solenoid Rewa Or Equavellent , Lifting Crane2 Ton -Level Switch Rewa Or Equavellent , Lifting Crane2 Ton -Wire Rope Rewa Or Equavellent , Lifting Crane3 Ton -Brake Liningrewa Or Equavellent , Lifting Crane3 Ton -Coil Breack Solenoid Rewa Or Equavellent , Lifting Crane3 Ton -Level Switch Rewa Or Equavellent , Lifting Crane3 Ton -Wire Rope Rewa Or Equavellent , Mainhole Earthing Cover (C I) -450X450 , Metal Helide -50 W Chowk , Metal Helide -50 W Ignitor , Metal Helide -50 W Lamp , Metal Helide -Battery Only , Metal Helide -Choke 100 W , Metal Helide -Choke 150 W , Metal Helide -Choke 50 W , Metal Helide -100 W , Metal Helide -150 W , Metal Helide -Solor Light12 V Complete , Motor5.5 Kw 1454 Rpm -Bearing , Motor5.5 Kw 1454 Rpm -Coupling Pulley , Motor5.5 Kw 1454 Rpm -Terminal Plate , Motor & Air Compressor Spares 55 Kw -Cable Grommet , Motor & Air Compressor Spares 55 Kw -Compressor , Motor & Air Compressor Spares 55 Kw -Lower Ball Bearing , Motor & Air Compressor Spares 55 Kw -Moisture Sensor Provideneoprine , Motor & Air Compressor Spares 55 Kw -Rotor Shaft , Motor & Air Compressor Spares 55 Kw -Upper Ball Bearing , Motor 1.1 Kw-Bearing , Motor 1.1 Kw-Coupling Pulley , Motor 1.1 Kw-Terminal Plate , Motor 1.5Kw 1400 Rpm -Bearing , Motor 1.5Kw 1400 Rpm -Coupling Pulley , Motor 1.5Kw 1400 Rpm -Terminal Plate , Motor 15 Kw-Bearing , Motor 15 Kw-Pulley , Motor 2.2 Kw 2830 Rpm -Bearing , Motor 2.2 Kw 2830 Rpm -Coupling Pulley , Motor 2.2 Kw 2830 Rpm -Terminal Platekirlosker/Upadhyay , Motor 22 Kw 1470 Rpm-Bearing , Motor 3.7 Kw2830rpm -Bearing , Motor 3.7 Kw2830rpm -Coupling Pulley , Motor 3.7 Kw2830rpm -Terminal Plate , Motor 450 Kw Rpm 1000 -Cable Gland , Motor 450 Kw Rpm 991 -Terminal Boxjyoti , Motor 450 Kw Rpm 992 -1.Spherical Bearing De Nu324mc3skf/Equallent , Motor 450 Kw Rpm 993 -2.Rollerbearing Nde,7322Cbem , Motor 450 Kw Rpm 994 -Gasket , Motor 450 Kw Rpm 995 -Bush , Motor 450 Kw Rpm 996 -Moisture Protector , Motor 450 Kw Rpm 997 -Bottom Clamp , Motor 450 Kw Rpm 999 -Cable Box , Motor 500 Kw Rpm 985 -Gland Bushneoprine , Motor 500 Kw Rpm 986 -1.Spherical Bearing De Nu226skf/Equallent , Motor 500 Kw Rpm 987 -2.Rollerbearing Nde,Qj320 , Motor 500 Kw Rpm 988 -Gland Bodynylon , Motor 500 Kw Rpm 989 -Terminal Sealing Plate , Motor 500 Kw Rpm 990 -Temperature Rtd , Motor 7.5 Kw-Bearing , Motor 7.5 Kw-Terminal Plate , Non Return Valve 1000 Mm-Newindian/Equvellent , Non Return Valve 1300 Mm-Newindian/Equvellent , Non Return Valve 600 Mm-Newindian/Equvellent , Outdoor V.C.B. Breaker-3.6 Kv 630 A Jyoti , Outdoor V.C.B. Breaker-Closing Coil 110 V , Outdoor V.C.B. Breaker-Opening Coil 110 V , Outdoor V.C.B. Breaker-Spring Charging Handle , Outdoor V.C.B. Breaker-Test Therminal Box , Plc Panal -16 Ch.24 V D/C Siemens , Plc Panal -32 Ch.24 V D/C Siemens , Plc Panal -8 Ch. 4-20 Masiemens , Plc Panal -Auxiliary Contectore Siemens , Plc Panal -Cpusiemens , Plc Panal -Desktop Coumputor Siemens , Plc Panal -Indication Lamp Siemens , Plc Panal -Interface Card Siemens , Plc Panal -Power Supply Siemens , Plc Panal -Printerhp , Plc Panal -Push Button Siemens , Plc Panal -Ups 2Kvamicromax , Pp Valve 40 Mm-Newhi-Tech Polymer , Pp Valve 50 Mm-Newhi-Tech Polymer , Pressure Gauge(Bourden Type) -0-1 Kg /Cm2a.N.Intrumation , Pressure Gauge(Bourden Type) -0-10 Kg /Cm2 , Pressure Gauge(Bourden Type) -0-4 Kg/Cm2 , Pvc Armoured Allum. Cable-3.5Cx25 Sq.Mmpolycap , Pvc Armoured Allum. Cable-3.5Cx300 Sq.Mmpolycap , Pvc Armoured Allum. Cable-3.5Cx50 Sq.Mmpolycap , Pvc Armoured Allum. Cable-3.5Cx95 Sq.Mmpolycap , Pvc Armoured Allum. Cable-3Cx120 Sq.Mmpolycap , Pvc Armoured Allum. Cable-3Cx150 Sq.Mmpolycap , Pvc Armoured Allum. Cable-3Cx185 Sq.Mmpolycap , Pvc Armoured Allum. Cable-3Cx4 Sq.Mmpolycap , Pvc Armoured Allum. Cable-3Cx70 Sq.Mmpolycap , Pvc Armoured Allum. Cable-4Cx10 Sq.Mmpolycap , Pvc Armoured Allum. Cable-4Cx4 Sq.Mm , Pvc Armoured Copper Cable-14Cx1.5 Sq.Mmpolycap , Pvc Armoured Copper Cable-14Cx2.5 Sq.Mmpolycap , Pvc Armoured Copper Cable-2Cx2.5 Sq.Mmpolycap , Pvc Armoured Copper Cable-30Cx2.5 Sq.Mmpolycap , Pvc Armoured Copper Cable-7Cx2.5 Sq.Mmpolycap , Raw Water Ph Meter - , Raw Water Turbidity Meter - , Sluice Gate 1200X1200 ( C I ) -Newjash Engg Ltd. , Sluice Gate 1350X1350 ( C I ) -Newjash Engg Ltd. , Sluice Gate 400X400 ( C I ) -Newjash Engg Ltd. , Sluice Gate 700X700( C I ) -Newjash Engg Ltd. , Sluice Gate 800X800( C I ) -Newjash Engg Ltd. , Sluice Valve Bross 50 Nb-Newisi , Soft Starter 450 Kw-Bridge Rectrifier , Soft Starter 450 Kw-Contactor (Mx 022E/220,110 V) , Soft Starter 450 Kw-Control Card , Soft Starter 450 Kw-Fcm Thermistore Relay Kanha , Soft Starter 450 Kw-Filter Capacetor , Soft Starter 450 Kw-Free Wheeling Diod , Soft Starter 450 Kw-Interpoing Contector L&T , Soft Starter 450 Kw-Supervisore Timer , Soft Starter 450 Kw-Vaccum By Pass Devace 6.6 Kv Cgl , Soft Starter 500 Kw-Bridge Rectrifier , Soft Starter 500 Kw-Contactor (Mx 022E/220,110 V) , Soft Starter 500 Kw-Control Card , Soft Starter 500 Kw-Fcm Thermistore Relay Kanha , Soft Starter 500 Kw-Filter Capacetor , Soft Starter 500 Kw-Free Wheeling Diod , Soft Starter 500 Kw-Interpoing Contector L&T , Soft Starter 500 Kw-Supervisore Timer , Soft Starter 500 Kw-Vaccum By Pass Devace 6.6 Kv Cgl , Solar Invertor With Battery -1 Kw , Solar Invertor With Battery -2 Kw , Transformer 1250 Kva 33/3.6 Kv -Cable Joint Kit ,Lugs , Transformer 1250 Kva 33/3.6 Kv -Jacking Pad , Transformer 1250 Kva 33/3.6 Kv -Oil Tank Filling Indicatore-Mco , Transformer 1250 Kva 33/3.6 Kv -Oil Temprature Indicator , Transformer 1250 Kva 33/3.6 Kv -Prismatic Oil Level Indicator , Transformer 1250 Kva 33/3.6 Kv -Silicagel Breather , Transformer 1250 Kva 33/3.6 Kv -Winding Tepreture Indicator , Transformer 2000 Kva 33/3.6 Kv -Buckhol Relay , Transformer 2000 Kva 33/3.6 Kv -Cable Jointer, Lugs , Transformer 2000 Kva 33/3.6 Kv -Jacking Pad , Transformer 2000 Kva 33/3.6 Kv -Oil Tank Filling Indicatore-Mco , Transformer 2000 Kva 33/3.6 Kv -Oil Tempreture Indicator , Transformer 2000 Kva 33/3.6 Kv -Prismatic Oil Level Indicator , Transformer 2000 Kva 33/3.6 Kv -Silicagel Breather , Transformer 2000 Kva 33/3.6 Kv -Winding Temprature Indicator , Transformer 315 Kva 33/0.433 Kv -Cable Joint Kit ,Lugs , Transformer 315 Kva 33/0.433 Kv -Jacking Pad , Transformer 315 Kva 33/0.433 Kv -Oil Tank Filling Indicatorknoher , Transformer 315 Kva 33/0.433 Kv -Oil Temprature Indicator , Transformer 315 Kva 33/0.433 Kv -Prismatic Oil Level Indicator , Transformer 315 Kva 33/0.433 Kv -Silicagel Breather , Transformer 315 Kva 33/0.433 Kv -Winding Tepreture Indicator , Ultrasonic Transmeter -3100 Serise Rosmount , Valve Actuators0.18 Kw-Contactor 24 V Dc Rotork/Auma , Valve Actuators0.18 Kw-Electronic Kitrotork/Auma , Valve Actuators0.18 Kw-Limit Switchrotork/Auma , Valve Actuators0.18 Kw-Newrotork/Auma , Valve Actuators0.36 Kw-Contactor 24 V Dc Rotork/Auma , Valve Actuators0.36 Kw-Electronic Kitrotork/Auma , Valve Actuators0.36 Kw-Limit Switchrotork/Auma , Valve Actuators0.36 Kw-Newrotork/Auma , Valve Actuators1.20 Kw-Contactor 24 V Dc Rotork/Auma , Valve Actuators1.20 Kw-Electronic Kitrotork/Auma , Valve Actuators1.20 Kw-Limit Switchrotork/Auma , Valve Actuators1.20 Kw-Newrotork/Auma , Valve Butter Fly(F631 Disc Di) 200 Mm-Newtyco Or Equavellent , Valve Butter Fly(F631 Disc Di) 200 Mm-Rubber Tyco Or Equavellent , Valve Butter Fly (F631 Disc Di) 100 Mm-Newtyco Or Equavellent , Valve Butter Fly (F631 Disc Di) 100 Mm-Rubbertyco Or Equavellent , Valve Butter Fly (F631 Disc Di) 1000 Mm-Newindian , Valve Butter Fly (F631 Disc Di) 1000 Mm-Rubber Tyco Or Equavellent , Valve Butter Fly (F631 Disc Di) 1200 Mm-Newindian , Valve Butter Fly (F631 Disc Di) 1200 Mm-Rubber , Valve Butter Fly (F631 Disc Di) 150 Mm-Newtyco Or Equavellent , Valve Butter Fly (F631 Disc Di) 150 Mm-Rubber Tyco Or Equavellent , Valve Butter Fly (F631 Disc Di) 300 Mm-Newtyco Or Equavellent , Valve Butter Fly (F631 Disc Di) 300 Mm-Rubber Tyco Or Equavellent , Valve Butter Fly (F631 Disc Di) 500 Mm-Newtyco Or Equavellent , Valve Butter Fly (F631 Disc Di) 500 Mm-Rubber Tyco Or Equavellent , Valve Butter Fly (F631 Disc Di) 600 Mm-Newtyco Or Equavellent , Valve Butter Fly (F631 Disc Di) 600 Mm-Rubber Tyco Or Equavellent , Valve Butter Fly (F631 Disc Di) 700 Mm-Newtyco Or Equavellent , Valve Butter Fly (F631 Disc Di) 700 Mm-Rubber Tyco Or Equavellent , Valve Butter Fly (F631 Disc Di) 800 Mm-Newtyco Or Equavellent , Valve Butter Fly (F631 Disc Di) 800 Mm-Rubber Tyco Or Equavellent , Vertical Turbine Pump 1818 M3/Hr 65.34 Metr Headmodel 30 30 M/2 Stg -80 Mm Head Shaft3 Mtr Long Flowmore , Vertical Turbine Pump 1818 M3/Hr 65.34 Metr Headmodel 30 30 M/2 Stg -Bearing Skf/Equallent , Vertical Turbine Pump 1818 M3/Hr 65.34 Metr Headmodel 30 30 M/2 Stg -Bearing For Discharge Caseflowmore , Vertical Turbine Pump 1818 M3/Hr 65.34 Metr Headmodel 30 30 M/2 Stg -Bearing Retainerci , Vertical Turbine Pump 1818 M3/Hr 65.34 Metr Headmodel 30 30 M/2 Stg -Bowl Bushflowmore , Vertical Turbine Pump 1818 M3/Hr 65.34 Metr Headmodel 30 30 M/2 Stg -Dischare Caseflowmore , Vertical Turbine Pump 1818 M3/Hr 65.34 Metr Headmodel 30 30 M/2 Stg -Flange Couplingm.S. , Vertical Turbine Pump 1818 M3/Hr 65.34 Metr Headmodel 30 30 M/2 Stg -Gasketflowmore , Vertical Turbine Pump 1818 M3/Hr 65.34 Metr Headmodel 30 30 M/2 Stg -Impellerflowmore , Vertical Turbine Pump 1818 M3/Hr 65.34 Metr Headmodel 30 30 M/2 Stg -Impeller Keyflowmore , Vertical Turbine Pump 1818 M3/Hr 65.34 Metr Headmodel 30 30 M/2 Stg -Line Shafts.S. , Vertical Turbine Pump 1818 M3/Hr 65.34 Metr Headmodel 30 30 M/2 Stg -Line Shaft Bearing , Vertical Turbine Pump 1818 M3/Hr 65.34 Metr Headmodel 30 30 M/2 Stg -Line Shaft Sleve , Vertical Turbine Pump 1818 M3/Hr 65.34 Metr Headmodel 30 30 M/2 Stg -Shaft Coupling En-1A , Vertical Turbine Pump 1818 M3/Hr 65.34 Metr Headmodel 30 30 M/2 Stg -Thrust Stand Assy , Vertical Turbine Pump 1818 M3/Hr 65.34 Metr Headmodel 30 30 M/2 Stg -Top Shaft , Vertical Turbine Pump 1818 M3/Hr 65.34 Metr Headmodel 30 30 M/2 Stg -Water Seal Ringbronze , Vertical Turbine Pump 2955 M3/Hr42.64Head Model 1P 129 -80 Mm Head Shaft3 Mtr Long Jyoti/Equavellent , Vertical Turbine Pump 2955 M3/Hr42.64Head Model 1P 130 -Strainnerjyoti/Equavellent , Vertical Turbine Pump 2955 M3/Hr42.64Head Model 1P 131 -Bottom Bearingjyoti/Equavellent , Vertical Turbine Pump 2955 M3/Hr42.64Head Model 1P 132 -Impeller Shaftjyoti/Equavellent , Vertical Turbine Pump 2955 M3/Hr42.64Head Model 1P 133 -Impellerjyoti/Equavellent , Vertical Turbine Pump 2955 M3/Hr42.64Head Model 1P 134 -Impeller Bearing Ringjyoti/Equavellent , Vertical Turbine Pump 2955 M3/Hr42.64Head Model 1P 135 -Bowl Bearing Ringjyoti/Equavellent , Vertical Turbine Pump 2955 M3/Hr42.64Head Model 1P 136 -Bowl Jyoti/Equavellent , Vertical Turbine Pump 2955 M3/Hr42.64Head Model 1P 137 -Bowl Bearing Jyoti/Equavellent , Vertical Turbine Pump 2955 M3/Hr42.64Head Model 1P 138 -Impeller Shaft Slevejyoti/Equavellent , Vertical Turbine Pump 2955 M3/Hr42.64Head Model 1P 139 -Taper Column Pipejyoti/Equavellent , Vertical Turbine Pump 2955 M3/Hr42.64Head Model 1P 140 -Line Shafts.S./Equavellent , Vertical Turbine Pump 2955 M3/Hr42.64Head Model 1P 141 -Line Shaft Sleves.S./Equavellent , Vertical Turbine Pump 2955 M3/Hr42.64Head Model 1P 142 -Line Shaft Bearings.S./Equavellent , Vertical Turbine Pump 2955 M3/Hr42.64Head Model 1P 143 -Column Pipes.S./Equavellent , Vertical Turbine Pump 2955 M3/Hr42.64Head Model 1P 144 -Discharge Pipes.S./Equavellent , Vertical Turbine Pump 2955 M3/Hr42.64Head Model 1P 145 -Top Column Pipes.S./Equavellent , Vertical Turbine Pump 2955 M3/Hr42.64Head Model 1P 146 -Top Shafts.S./Equavellent , Vertical Turbine Pump 2955 M3/Hr42.64Head Model 1P 147 -Pump Bases.S./Equavellent , Vertical Turbine Pump 2955 M3/Hr42.64Head Model 1P 148 -Stuffing Box Bearings.S./Equavellent , Vertical Turbine Pump 2955 M3/Hr42.64Head Model 1P 150 -Motor Skirts.S./Equavellent , Vertical Turbine Pump 2955 M3/Hr42.64Head Model 1P 151 -Ratchets.S./Equavellent , Vertical Turbine Pump 2955 M3/Hr42.64Head Model 1P 152 -Vertical Solid Shaft Motors.S./Equavellent , Woolen Met -
Contract Date : 12 Feb, 2025   |   Contract Value : 7.71 Crore
BRR : 1429651 Annual Rates Contract For Material Purchase Under Jmc Forcity Water Supply - Automatic Push Button Starter Pannel L&T -3 Hp To 7.5 Hp 3 Automatic Push Button Starter Pannel L&T-10 Hp 4 Automatic Push Button Starter Pannel L&T-15 Hp 5 Automatic Push Button Starter Pannel L&T-20 Hp 6 Automatic Push Button Starter Pannel Cutler Hammer 3Hp To 7.5Hp 7 Automatic Push Button Starter Pannel Cutler Hammer 10 Hp 8 Automatic Push Button Starter Pannel Cutler Hammer 15 Hp 9 Automatic Push Button Starter Pannel Cutler Hammer 20 Hp 10 Main Switch Tpnmake Ssk-16 Amp 11 Main Switch Tpnmake Ssk-32 Amp 12 Main Switch Tpnmake Ssk-63 Amp 13 Main Switch Tpnmake Ssk-100 Amp 14 Main Switch Tpnmake Ssk-200 Amp 15 Main Switch Tpn Make Ssk-400 Amp 16 Cut Out With Basemake Ssk-16 Amp 17 Cut Out With Basemake Ssk-32 Amp 18 Cut Out With Basemakessk-63 Amp 19 Cut Out With Basemake Ssk-100 Amp 20 Cut Out With Basemake Ssk-200 Amp 21 Cut Out With Basemake Ssk-400 Amp 22 Main Switch Tphavvels Make 16 Amp 23 Main Switch Tphavvels Make 32 Amp 24 Main Switch Tphavvels Make63 Amp 25 Main Switch Tphavvels Make 100 Amp 26 Main Switch Tphavvels Make 200 Amp 27 Main Switch Tphavvels Make 400 Amp 28 Pvc Wire-Copper Anchor / Havvels-.3 / 20 29 Pvc Wire Coppe Anchor / Havvels 7 / 16 30 Pvc Wire-Copper Anchor / Havvels.7 / 20 31 Pvc Wire-Copper Anchor / Havvels.19 / 16 32 Gi Wire All Guage Galvanized Hotdrip 33 Pvc Armoured Cable Aluminium 3Core National-4 Sqmm 34 Pvc Armoured Cable Aluminium 3Core National-6 Sqmm 35 Pvc Armoured Cable Aluminium 3Core National-8 Sqmm 36 Pvc Armoured Cable Aluminium 3Core National-10 Sqmm 37 Pvc Armoured Cable Aluminium 3Core National-16 Sqmm 38 Pvc Armoured Cable Aluminium 3Core National-25 Sqmm 39 Pvc Armoured Cable Aluminium 3Core National-60 Sqmm 40 Pvc Armoured Cable Aluminium 3Core National-100 Sqmm 41 Pvc Armoured Cable Aluminium 3Core National-120 Sqmm 42 Pvc Armoured Cable Aluminium 3Core National-200 Sqmm 43 Pvc Armoured Cable Aluminium 3Core National-300 Sqmm 44 Pvc Armoured Cable Aluminium 3Core National-400 Sqmm 45 Pvc Armoured Cable Aluminium 3Core National-500 Sqmm 46 Submersible Cable Flat 3Core Finolex-1.5 Sqmm 47 Submersible Cable Flat 3Core Finolex-2.5 Sqmm 48 Submersible Cable Flat 3Core Finolex-4 Sqmm 49 Submersible Cable Flat 3Core Finolex-6 Sqmm 50 Capacitor 415 Volt Isi Mark ( Crompton / Siemens ) Make, Mpp Type 51 Capacitor 415Volt L&T Make Isi , Mpp Type 52 Steel Grip Tape Anchor Make -15Mm ( ½ ) 53 Steel Grip Tape Anchor Make -20Mm ( ¾ ) 54 Nut Bolt All Sizes Full & Half Thread WMake- 55 Gi Long Socket Heavy For Submersible Pump Bharat Make- 32Mm ( 1¼ ) 56 Gi Long Socket Heavy For Submersible Pump Bharat Make- 40Mm ( 1½ ) 57 Gi Long Socket Heavy For Submersible Pump Bharat Make- 50Mm ( 2 ) 58 Gi Long Socket Heavy For Submersible Pump Bharat Make- 65Mm ( 2½ ) 59 Gi Long Socket Heavy For Submersible Pump Bharat Make- 80Mm ( 3 ) 60 Steel Bush Heavy For Tube Well Forged-1¼X1½ 61 Steel Bush Heavy For Tube Well Forged-1½X2 62 Steel Bush Heavy For Tube Well Forged-2X2½ 63 Steel Bush Heavy For Tube Well Forged-2½X3 64 Steel Bush Heavy For Tube Well Forged-2X3 65 Well Cap For Tube Well Mildsteel-125Mm ( 5 ) 66 Well Cap For Tube Well Mildsteel-150Mm ( 6 ) 67 Well Cap For Tube Well Mildsteel-180Mm ( 7 ) 68 Well Cap For Tube Well Mildsteel-200Mm ( 8 ) 69 M S Clamp For Tube Well Mildsteel-32Mm ( 1¼ ) 70 M S Clamp For Tube Well Mildsteel-40Mm ( 1½ ) 71 M S Clamp For Tube Well Mildsteel-50Mm ( 2 ) 72 M S Clamp For Tube Well Mildsteel-65Mm ( 2½ ) 73 M S Clamp For Tube Well Mildsteel-80Mm ( 3 ) 74 Cable Joint Rubber Role Dunlop- 75 Pvc Flexible Pipe Shrinath-40Mm ( 1¼ ) 76 Pvc Flexible Pipe Shrinath-50Mm ( 1½ ) 77 Earth Plate Heavycopper-1X1 Ft 78 Earth Plate Heavygalvanized-1X1 Ft 79 Spare Point Kit For Starter L&T / Hammer Cuttler -3 To 7-5 Hp 80 Spare Point Kit For Starter L&T / Hammer Cuttler-10 To 20 Hp 81 No Volt Coil For Starter L&T / Hammer Cuttler-3 To 7-5 Hp 82 No Volt Coil For Starter L&T / Hammer Cuttler-10 To 20 Hp 83 Soldring Alkapy Ambika / Khosla-60 / 40 84 Soldring Wire Ambika / Khosla-60 / 40 85 Flux Bottel 181 Isi 86 Copper Patti / Rod Superier Quality- 87 Bekalite Sheet All Size Heavy Pressed- 88 Ms Steel Sheet Box 20Gage Incl Plyboard, Angle Stand & With Lock Fabricated- Size 4X 4 X 2 89 Ms Steel Sheet Box 20Gage Incl Plyboard, Angle Stand & With Lock Fabricated-Size2X2 90 Steel Flange Table-D-50Mm ( 2 ) 91 Steel Flange Table-D-65Mm ( 2½ ) 92 Steel Flange Table-D-80Mm ( 3 ) 93 Steel Flange Table-D-100Mm ( 4 ) 94 Steel Flange Table-D-150Mm ( 6 ) 95 Gland Packing All Size Turner / Champion Make- 96 Over Load Relay For Starter L&T Make 9 - 14 Amp 97 Over Load Relay For Starter L&T Make14 - 21 Amp 98 Over Load Relay For Starter Cuttler Hammer Make 9 - 14 Amp 99 Over Load Relay For Starter Cuttler Hammer Make 14- 21Amp 100 Contactor For Automatic Starter L&T Make-25 Amp 101 Contactor For Automatic Starter L&T Make-40 Amp 102 Contactor For Automatic Starter Cuttler Hammer Make-25 Amp 103 Contactor For Automatic Starter Cuttler Hammer Make-40 Amp 104 Service Line Single Phase Aluminium Wire National-6 Sqmm 105 Service Line Single Phase Aluminium Wire National-8 Sqmm 106 Service Line Single Phase Aluminium Wire National-10 Sqmm 107 Service Line Single Phase Aluminium Wire National-12 Sqmm 108 Suction Pipe Heavy Duty Pvc Make Premier / Equilent-40Mm ( 1¼ ) 109 Suction Pipe Heavy Duty Pvc Make Premier / Equilent-50Mm ( 1½ ) 110 Suction Pipe Heavy Duty Pvc Make Premier / Equilent-63Mm ( 2 ) 111 Suction Pipe Heavy Duty Pvc Make Premier / Equilent-75Mm ( 2½ ) 112 Suction Pipe Heavy Duty Pvc Make Premier / Equilent-80Mm ( 3 ) 113 Suction Pipe Heavy Duty Pvc Make Premier / Equilent-110Mm ( 4 ) 114 Rubber Sheet All Thickness Oxford / Orient-White 115 Rubber Sheet All Thickness Oxford / Orient-Black 116 Volt Meter 0.500 Volt Essma-150Mm ( 6 ) 117 Volt Meter 0.500 Volt Essma-100Mm ( 4 ) 118 Volt Meter 0.500 Volt Essma-65Mm ( 2½ ) 119 Ampere Meter All Amp Essma-150Mm ( 6 ) 120 Ampere Meter All Amp Essma-100Mm ( 4 ) 121 Ampere Meter All Amp Essma-65Mm ( 2½ ) 122 Starter For Single Phase Paramount / Equilent-1 H.P. 123 Starter For Single Phase Paramount / Equilent-1½ H.P. 124 Starter For Single Phase Paramount / Equilent -2 H.P. 125 Auxilary Switch - For All Starter 126 Button For Starter-5 H.P.To 20 H.P. 127 Button For Starter Above 20 H P 128 Hose Nipple Heavy Long -25Mm ( 1 ) 129 Hose Nipple Heavy Long -32Mm ( 1¼ ) 130 Hose Nipple Heavy Long -40Mm ( 1½ ) 131 Hose Nipple Heavy Long -50Mm ( 2 ) 132 Hose Nipple Heavy Long -65Mm ( 2½ ) 133 Hose Nipple Heavy Long -80Mm ( 3 ) 134 Hose Clamp -25Mm ( 1 ) 135 Hose Clamp -32Mm ( 1¼ ) 136 Hose Clamp -40Mm ( 1½ ) 137 Hose Clamp -50Mm ( 2 ) 138 Hose Clamp -65Mm ( 2½ ) 139 Hose Clamp-80Mm ( 3 ) 140 Plastic Coated Wire 6 Mm Rope For Hdpe Pipe- 141 India Mark Ll Unicef Heavy Design Hand Pump Machine Complete Assembly Isi- Galvnized 142 Handle Complete With Bearing, Axel, Chain, Complete For India Mark 2Hand Pump Galvnized 143 Water Chamber Heavy For India Mark 2.-Hand Pump Galvnized 144 Pedistal Heavy For India Mark 2.-Hand Pump Galvnized 145 Cylinder Complete For India Mark 2.-Hand Pump Complete Heavy 146 Plunjer Rod Stainless Steel Heavy-For Cylinder 147 Reducer Cap- For Cylinder 148 Upper Valve Assembly Gm With Upper Valve Guide, Spacergun Metel Heavy-For Cylinder 149 Lower Valve Assembly With Rubber Sheetgun Metal For Cylinder 150 Handle Axle Stainless Steel India Mark Ll- Hand Pump 151 Ball Bearing 6204 Mark Ll Double Sealed Nbc / Equilent- 152 Chain With Coupler Mark Ll Heavy 153 Front Cover Galvanized Heavy- 154 High-Tension Bolt Galvanized- 155 Conversion Head Center Plate Galvanized- 156 Hex Nut Bolt Galvanized-10Mmx40mm 157 Connecting Rod Galvanized 12 Mmx3mtr Heavy- 158 Rubber Washer Mark Ll Superior-Quality 159 Leather Washer Bucket Shakti Make-Mark Ll 160 Rod Socket 12 Mm Galvanized- 161 Pipe Socket 1 1 / 4 Isi Gi Heavy- 162 Upper Valve Guide Mark Ll Gm 163 Motor Varnish- 164 Bearing Grease Ap3 Or Imi 165 Starter Panel For Single Phase Motor Pump With Ampmeter & Volt Meter- 1Hp 166 Starter Panel For Single Phase Motor Pump With Ampmeter & Volt Meter- 1.50Hp 167 Starter Panel For Single Phase Motor Pump With Ampmeter & Volt Motor- 2Hp 168 Squarebush For Pump Coupling 200Hp 169 Squarebush For Pump Coupling 150Hp 170 Square Bush For Pump Coupling 120Hp 171 Square Bush For Pump Coupling 100Hp 172 Square Bush For Pump Coupling 60Hp 173 Square Bush For Pump Coupling 50Hp 174 Square Bush For Pump Coupling 40Hp 175 Square Bush For Pump Coupling 25Hp, 20Hp 30Hp 176 Square Bush For Pump Coupling 15Hp 177 Square Bush For Pump Coupling 10Hp 178 Square Bush For Pump Coupling 5Hp 179 Square Bush For Pump Coupling 3Hp 180 Contactor Point Set For Starter 150 Hp 181 Transformer Oil B Grade Super Quality- Isi 182 Nailsall Sizes- 183 Copper Lugs Heavy Dowells-15Sqmm 184 Copper Lugs Heavy Dowells-30Sqmm 185 Copper Lugs Heavy Dowells-40 Sqmm 186 Copper Lugs Heavy Dowells-50 Sqmm 187 Copper Lugs Heavy Dowells-60 Sqmm 188 Copper Lugs Heavy Dowells-70 Sqmm 189 Copper Lugs Heavy Dowells-80 Sqmm 190 Copper Lugs Heavy Dowells-90 Sqmm 191 Copper Lugs Heavy Dowells-100 Sqmm 192 Copper Lugs Heavy Dowells-200 Sqmm 193 Copper Lugs Heavy Dowells-300 Sqmm 194 Copper Lugs Heavy Dowells-400 Sqmm 195 Copper Lugs Heavy Dowells-500 Sqmm 196 Copper Lugs Heavy Dowells-800 Sqmm 197 Alluminium Lugs Heavy Dowells-30 Sqmm 198 Alluminium Lugs Heavy Dowells-40 Sqmm 199 Alluminium Lugs Heavy Dowells-50 Sqmm 200 Alluminium Lugs Heavy Dowells-60 Sqmm 201 Alluminium Lugs Heavy Dowells-70 Sqmm 202 Alluminium Lugs Heavy Dowells-80 Sqmm 203 Alluminium Lugs Heavy Dowells-90 Sqmm 204 Alluminium Lugs Heavy Dowells-100 Sqmm 205 Alluminium Lugs Heavy Dowells-200 Sqmm 206 Alluminium Lugs Heavy Dowells-300 Sqmm 207 Alluminium Lugs Heavy Dowells-400 Sqmm 208 Alluminium Lugs Heavy Dowells-500 Sqmm 209 Alluminium Lugs Heavy Dowells-800 Sqmm 210 Araldite 211 Exhaust Fan Gec / Crompton Make 450Mm 212 Exhaust Fan Gec / Crompton-600Mm ( 24 ) 213 Exhaust Fan Gec / Crompton-900Mm ( 36 ) 214 Wire Brush Heavy Duty- Iron 215 Wire Brush Heavy Duty-Plastic 216 Wire Brush Heavy Duty- Brass 217 Plastic Tokni- 218 Flower Broom 219 Stick Broom 220 Foot Valve Heavy Isi Mark-50Mm ( 2 ) 221 Foot Valve Heavy Isi Mark-80Mm ( 3 ) 222 Foot Valve Heavy Isi Mark-100Mm ( 4 ) 223 Foot Valve Heavy Isi Mark-150Mm ( 6 ) 224 Foot Valve Heavy Isi Mark-200Mm ( 8 ) 225 Foot Valve Heavy Isi Mark-250Mm ( 10 ) 226 Foot Valve Heavy Isi Mark-300Mm ( 12 ) 227 Cleaning Powder 228 Cement Fencing Pole- 229 Barbed Wire 230 Mobile Oil-20 No. Castrol / Servo 231 Mobile Oil-40 No.Castrol / Servo 232 Mobile Oil-60 No.Castrol / Servo 233 Mobile Oil-80 No.Castrol / Servo 234 Mobile Oil-90 No.Castrol / Servo 235 Mobile Oil-100 No. Castrol / Servo 236 Mobile Oil-150 No. Castrol / Servo 237 Mobile Oil-320 No. Castrol / Servo 238 Shockproof Rubber Mating For 11000 Volt 1M.X 2M- 239 Die Set-1 To ½ Complete Hira Make 240 Die Set-1¼ To 2 Complete Hira Make 241 Pipe Wrench-900Mm ( 36 ) Make Taparia 242 Pipe Wrench-600Mm ( 24 ) Make Taparia 243 Pipe Wrench-450Mm ( 18 ) Make Taparia 244 Pipe Wrench-350Mm ( 14 ) Make Taparia 245 Pipe Wrench-300Mm ( 12 ) Make Taparia 246 Chain Wrench-150Mm ( 6 ) Make Hira 247 Chain Wrench-100Mm ( 4 ) Make Hira 248 Chain Wrench-80Mm ( 3 ) Make Hira 249 Tap-50Mm ( 2 ) 250 Tap-40Mm ( 1½ ) 251 Tap-32Mm ( 1¼ ) 252 Tap-25Mm ( 1 ) 253 Tap-20Mm ( ¾ ) 254 Tap-15Mm ( ½ ) 255 Fix Spanner Set-6 No.- To 32 No- Taparia 256 Ring Spanner Set-6 No.- To 32 No-Taparia 257 Hexa Frame Hira Make 258 Hexa Blade Single 259 Hexa Blade Double Tata Make 260 Hammer 8 Lbs 261 Hammer 10 Lbs 262 Hammer 4 Lbs 263 Hammer 6 Lbs 264 Hammer 2 Lbs 265 Gainti Heavy Duty 266 Tasla ( Ghamela ) Heavy Guage 267 Gi Pipe A Classisi Mark Without Socket - Jadia, Jindal, Surya, Swasthik Or Equilent -15Mm ( ½ ) 268 Gi Pipe A Class Isi Mark Without Socket - Jadia, Jindal, Surya, Swasthik Or Equilent -20Mm ( ¾ ) 269 Gi Pipe A Class Isi Mark Without Socket - Jadia, Jindal, Surya, Swasthik Or Equilent -25Mm ( 1 ) 270 Gi Pipe A Class Isi Mark Without Socket - Jadia, Jindal, Surya, Swasthik Or Equilent -32Mm ( 1¼ ) 271 Gi Pipe A Class Isi Mark Without Socket- Jadia, Jindal, Surya, Swasthik Or Equilent -40Mm ( 1½ ) 272 Gi Pipe A Class Isi Mark Without Socket - Jadia, Jindal, Surya, Swasthik Or Equilent -50Mm ( 2 ) 273 Gi Pipe A Classisi Mark Without Socket - Jadia, Jindal, Surya, Swasthik Or Equilent -65Mm ( 2½ ) 274 Gi Pipe A Class Isi Mark Without Socket - Jadia, Jindal, Surya, Swasthik Or Equilent -80Mm ( 3 ) 275 Gi Pipe A Class Isi Mark Without Socket - Jadia, Jindal, Surya, Swasthik Or Equilent -100Mm ( 4 ) 276 Gi Pipe B Class Isi Mark Without Socket - Jadia, Jindal, Surya, Swasthik Or Equilent -15Mm ( ½ ) 277 Gi Pipe B Class Isi Mark Without Socket - Jadia, Jindal, Surya, Swasthik Or Equilent -20Mm ( ¾ ) 278 Gi Pipe B Class Isi Mark Without Socket - Jadia, Jindal, Surya, Swasthik Or Equilent -25Mm ( 1 ) 279 Gi Pipe B Class Isi Mark Without Socket - Jadia, Jindal, Surya, Swasthik Or Equilent -32Mm ( 1¼ ) 280 Gi Pipe B Class Isi Mark Without Socket - Jadia, Jindal, Surya, Swasthik Or Equilent -40Mm ( 1½ ) 281 Gi Pipe B Class Isi Mark Without Socket - Jadia, Jindal, Surya, Swasthik Or Equilent -50Mm ( 2 ) 282 Gi Pipe B Class Isi Mark Without Socket - Jadia, Jindal, Surya, Swasthik Or Equilent -65Mm ( 2½ ) 283 Gi Pipe B Class Isi Mark Without Socket - Jadia, Jindal, Surya, Swasthik Or Equilent -80Mm ( 3 ) 284 Gi Pipe B Class Isi Mark Without Socket - Jadia, Jindal, Surya, Swasthik Or Equilent -100Mm ( 4 ) 285 Gi Pipe B Class Isi Mark Without Socket - Jadia, Jindal, Surya, Swasthik Or Equilent -150Mm ( 6 ) 286 Gi Socket Isi Mark-15Mm ( ½ ) 287 Gi Socket Isi Mark-20Mm ( ¾ ) 288 Gi Socket Isi Mark-25 ( 1 ) 289 Gi Socket Isi Mark-32Mm ( 1¼ ) 290 Gi Socket Isi Mark-40Mm ( 1½ ) 291 Gi Socket Isi Mark-50Mm ( 2 ) 292 Gi Socket Isi Mark-65Mm ( 2½ ) 293 Gi Socket Isi Mark-80Mm ( 3 ) 294 Gi Socket Isi Mark-100Mm ( 4 ) 295 Gi Socket Isi Mark-150Mm ( 6 ) 296 Gi Elbow Isi Mark Kirti, Vimco-15Mm ( ½ ) 297 Gi Elbow Isi Mark Kirti, Vimco-20Mm ( ¾ ) 298 Gi Elbow Isi Mark Kirti, Vimco-25Mm ( 1 ) 299 Gi Elbow Isi Mark Kirti, Vimco-32Mm ( 1¼ ) 300 Gi Elbow Isi Mark Kirti, Vimco-40Mm ( 1½ ) 301 Gi Elbow Isi Mark Kirti, Vimco-50Mm ( 2 ) 302 Gi Elbow Isi Mark Kirti, Vimco-65Mm ( 2½ ) 303 Gi Elbow Isi Mark Kirti, Vimco-80Mm ( 3 ) 304 Gi Elbow Isi Mark Kirti, Vimco-100Mm ( 4 ) 305 Gi Elbow Isi Mark Kirti, Vimco-150Mm ( 6 ) 306 Gi Tee Kirti, Vimco-15Mm ( ½ ) 307 Gi Tee Kirti, Vimco-20Mm ( ¾ ) 308 Gi Tee Kirti, Vimco-25Mm Mm ( 1 ) 309 Gi Tee Kirti, Vimco-32Mm ( 1¼ ) 310 Gi Tee Kirti, Vimco-40Mm ( 1½ ) 311 Gi Tee Kirti, Vimco-50Mm ( 2 ) 312 Gi Tee Kirti, Vimco-65Mm ( 2½ ) 313 Gi Tee Kirti, Vimco-80Mm ( 3 ) 314 Gi Tee Kirti, Vimco-100Mm ( 4 ) 315 Gi Tee Kirti, Vimco-150Mm ( 6 ) 316 Gi Union Kirti, Vimco-15Mm ( ½ ) 317 Gi Union Kirti, Vimco-20Mm ( ¾ ) 318 Gi Union Kirti, Vimco-25Mm ( 1 ) 319 Gi Union Kirti, Vimco-32Mm ( 1¼ ) 320 Gi Union Kirti, Vimco-40Mm ( 1½ ) 321 Gi Union Kirti, Vimco-50Mm ( 2 ) 322 Gi Union Kirti, Vimco-65Mm ( 2½ ) 323 Gi Union Kirti, Vimco-80Mm ( 3 ) 324 Gi Union Kirti, Vimco-100Mm ( 4 ) 325 Gi Union Kirti, Vimco-150Mm ( 6 ) 326 Steel Hex Nipple-15Mm ( ½ ) 327 Steel Hex Nipple-20Mm ( ¾ ) 328 Steel Hex Nipple-25Mm ( 1 ) 329 Steel Hex Nipple-32Mm ( 1¼ ) 330 Steel Hex Nipple-40Mm ( 1½ ) 331 Steel Hex Nipple-50Mm ( 2 ) 332 Steel Hex Nipple-65Mm ( 2½ ) 333 Steel Hex Nipple-80Mm ( 3 ) 334 Steel Hex Nipple-100Mm ( 4 ) 335 Steel Hex Nipple-150Mm ( 6 ) 336 Gi Nipple 12 Long Isi Mark Pipe-15Mm ( ½ ) 337 Gi Nipple 12 Long Isi Mark Pipe-20Mm ( ¾ ) 338 Gi Nipple 12 Long Isi Mark Pipe-25Mm ( 1 ) 339 Gi Nipple 12 Long Isi Mark Pipe-32Mm ( 1¼ ) 340 Gi Nipple 12 Long Isi Mark Pipe-40Mm ( 1½ ) 341 Gi Nipple 12 Long Isi Mark Pipe-50Mm ( 2 ) 342 Gi Nipple 12 Long Isi Mark Pipe-65Mm ( 2½ ) 343 Gi Nipple 12 Long Isi Mark Pipe-80Mm ( 3 ) 344 Gi Nipple 12 Long Isi Mark Pipe-100Mm ( 4 ) 345 Gi Nipple 12 Long Isi Mark Pipe-150Mm ( 6 ) 346 Gm Gate Valveheavy Isi Mark-15Mm ( ½ ) 347 Gm Gate Valveheavy Isi Mark-20Mm ( ¾ ) 348 Gm Gate Valveheavy Isi Mark-25Mm ( 1 ) 349 Gm Gate Valveheavy Isi Mark-32Mm ( 1¼ ) 350 Gm Gate Valveheavy Isi Mark-40Mm ( 1½ ) 351 Gm Gate Valveheavy Isi Mark-50Mm ( 2 ) 352 Gm Gate Valveheavy Isi Mark-65Mm ( 2½ ) 353 Gm Gate Valveheavy Isi Mark-80Mm ( 3 ) 354 Gm Gate Valveheavy Isi Mark-100Mm ( 4 ) 355 Gm Gate Valveheavy Isi Mark-150Mm ( 6 ) 356 Gi Bend Heavy Duty-15Mm ( ½ ) 357 Gi Bend Heavy Duty-20Mm ( ¾ ) 358 Gi Bend Heavy Duty-25Mm ( 1 ) 359 Gi Bend Heavy Duty-32Mm ( 1¼ ) 360 Gi Bend Heavy Duty-40Mm ( 1½ ) 361 Gi Bend Heavy Duty-50Mm ( 2 ) 362 Gi Bend Heavy Duty-65Mm ( 2½ ) 363 Gi Bend Heavy Duty-80Mm ( 3 ) 364 Gi Bend Heavy Duty-100Mm ( 4 ) 365 Gi Bend Heavy Duty-150Mm ( 6 ) 366 Steel Plug Heavy Quality-15Mm ( ½ ) 367 Steel Plug Heavy Quality-20Mm ( ¾ ) 368 Steel Plug Heavy Quality-25Mm ( 1 ) 369 Steel Plug Heavy Quality-32Mm ( 1¼ ) 370 Steel Plug Heavy Quality-40Mm ( 1½ ) 371 Steel Plug Heavy Quality-50Mm ( 2 ) 372 Steel Plug Heavy Quality-65Mm ( 2½ ) 373 Steel Plug Heavy Quality-80Mm ( 3 ) 374 Steel Plug Heavy Quality-100Mm ( 4 ) 375 Steel Plug Heavy Quality-150Mm ( 6 ) 376 Steel Bush-15Mm ( ½ ) 377 Steel Bush-20Mm ( ¾ ) 378 Steel Bush-25Mm ( 1 ) 379 Steel Bush-32Mm ( 1¼ ) 380 Steel Bush-40Mm ( 1½ ) 381 Steel Bush-50Mm ( 2 ) 382 Steel Bush-65Mm ( 2½ ) 383 Steel Bush-80Mm ( 3 ) 384 Steel Bush-100Mm ( 4 ) 385 Steel Bush-150Mm ( 6 ) 386 Gi Reducer Tee - Kirti, Vimco Isi-15Mm ( ½ ) 387 Gi Reducer Tee - Kirti, Vimco Isi-20Mm ( ¾ ) 388 Gi Reducer Tee - Kirti, Vimco Isi-25Mm ( 1 ) 389 Gi Reducer Tee - Kirti, Vimco Isi-32Mm ( 1¼ ) 390 Gi Reducer Tee - Kirti, Vimco Isi-40Mm ( 1½ ) 391 Gi Reducer Tee - Kirti, Vimco Isi-50Mm ( 2 ) 392 Gi Reducer Tee - Kirti, Vimco Isi-65Mm ( 2½ ) 393 Gi Reducer Tee - Kirti, Vimco Isi-80Mm ( 3 ) 394 Gi Reducer Tee - Kirti, Vimco Isi-100Mm ( 4 ) 395 Gi Reducer Tee - Kirti, Vimco Isi-150Mm ( 6 ) 396 Gi Reducer Socket-15Mm ( ½ ) 397 Gi Reducer Socket-20Mm ( ¾ ) 398 Gi Reducer Socket-25Mm ( 1 ) 399 Gi Reducer Socket-32Mm ( 1¼ ) 400 Gi Reducer Socket-40Mm ( 1½ ) 401 Gi Reducer Socket-50Mm ( 2 ) 402 Gi Reducer Socket-65Mm ( 2½ ) 403 Gi Reducer Socket-80Mm ( 3 ) 404 Gi Reducer Socket-100Mm ( 4 ) 405 Gi Reducer Socket-150Mm ( 6 ) 406 Gi Reducer Elbow-15Mm ( ½ ) 407 Gi Reducer Elbow-20Mm ( ¾ ) 408 Gi Reducer Elbow-25Mm ( 1 ) 409 Gi Reducer Elbow-32Mm ( 1¼ ) 410 Gi Reducer Elbow-40Mm ( 1½ ) 411 Gi Reducer Elbow-50Mm ( 2 ) 412 Gi Reducer Elbow-65Mm ( 2½ ) 413 Gi Reducer Elbow-80Mm ( 3 ) 414 Gi Reducer Elbow-100Mm ( 4 ) 415 Gi Reducer Elbow-150Mm ( 6 ) 416 Converson Head Complete With Handle, Axel, Bearing, Chain Complete For India Mark Ll Hand Pump 417 Chisel Heavy-100Mm ( 4 ) 418 Chisel Heavy-150Mm ( 6 ) 419 Chisel Heavy-225Mm ( 9 ) 420 Chisel Heavy-300Mm ( 12 ) 421 Rope Cocking Tool 422 Lead Cocking Tool 423 Gaiti Handle 424 Fawda Handle 425 Butter Fly Valve Isi Mark-150Mm ( 6 ) 426 Butter Fly Valve Isi Mark-200Mm ( 8 ) 427 Butter Fly Valve Isi Mark-250Mm ( 10 ) 428 Butter Fly Valve Isi Mark-300Mm ( 12 ) 429 Butter Fly Valve Isi Mark-350Mm ( 14 ) 430 Butter Fly Valve Isi Mark-400Mm ( 16 ) 431 Butter Fly Valve Isi Mark-450Mm ( 18 ) 432 Butter Fly Valve Isi Mark-500Mm ( 20 ) 433 Butter Fly Valve Isi Mark-600Mm ( 24 ) 434 Non Return Valve Normex Or Equilent-150Mm ( 6 ) 435 Non Return Valve Normex Or Equilent-200Mm ( 8 ) 436 Non Return Valve Normex Or Equilent-250Mm ( 10 ) 437 Non Return Valve Normex Or Equilent-300Mm ( 12 ) 438 Non Return Valve Normex Or Equilent-80Mm ( 3 ) 439 Non Return Valve Normex Or Equilent-100Mm ( 4 ) 440 Non Return Valve Normex Or Equilent-50Mm ( 2 ) 441 Non Return Valve Normex Or Equilent-350Mm ( 14 ) 442 Non Return Valve Normex Or Equilent-400Mm ( 16 ) 443 Non Return Valve Normex Or Equilent-450Mm ( 18 ) 444 Non Return Valve Normex Or Equilent-500Mm ( 20 ) 445 Non Return Valve Normex Or Equilent-600Mm ( 24 ) 446 Non Return Valve Normex Or Equilent-700Mm ( 28 ) 447 Non Return Valve Normex Or Equilent-750Mm ( 30 ) 448 Non Return Valve Normex Or Equilent-900Mm ( 36 ) 449 Foot Valve Normex Or Equilent -150Mm ( 6 ) 450 Foot Valve Normex Or Equilent-200Mm ( 8 ) 451 Foot Valve Normex Or Equilent-250Mm ( 10 ) 452 Foot Valve Normex Or Equilent-300Mm ( 12 ) 453 Open Well Submersible Pump High Head Isi Mark-3 H.P. 454 Open Well Submersible Pump High Head Isi Mark-5 H.P. 455 Open Well Submersible Pump High Head Isi Mark-10 H.P. 456 Upvc Pipe Ashirwad / Birla -2 457 Upvc Adopter 2 458 Tublarpipe20ft Length For Cable Support 459 Security Chain ( For Well Pump ) 460 Hdpe Water Storage Tank Plasto, Dhara Or Equilent Make 461 Ms Pipe Heavy All Sizes- 462 Hand Gloves Super Quality-11 Kv Load 463 Hand Gloves Super Quality-33 Kv Load 464 Chlorinator Monitar Manual Control Specification Clorine Dose 5 Kg Per Hour Completetrail & Testing For Filter Plant 465 Cp Steel Bib Cock ( Chavi ) 1 / 2 Heavy- 466 Pipe Vice Heavy-2 No. Hira Or Equilent 467 Pipe Vice Heavy-3 No. Hira Or Equilent 468 Pipe Lifter 1 1 / 4- 469 Screw Driver Everest / Tapariya- -150Mm ( 6 ) 470 Screw Driver Everest / Tapariya- -200Mm ( 8 ) 471 Screw Driver Everest / Tapariya- -300Mm ( 12 ) 472 Pllier Everest / Tapariya -200Mm ( 8 ) 473 Pllier Everest / Tapariya -250Mm ( 10 ) 474 Hamp Rope 475 Sun- 476 White Putty - ( Safeda ) 477 Ferule Gun Metal H.D 478 Wash Basin Tap Heavy-15Mm ( ½ ) 479 Ci Tapper Cock-15Mm ½ Long Handle 480 Brass Bib Cock Heavy-15Mm ( ½ ) 481 Tyton Rubber-80Mm ( 3 ) 482 Tyton Rubber-100Mm ( 4 ) 483 Tyton Rubber-150Mm ( 6 ) 484 Tyton Rubber-200Mm ( 8 ) 485 Tyton Rubber-300Mm ( 12 ) 486 Tyton Rubber-450Mm ( 18 ) 487 Tyton Rubber-600Mm ( 24 ) 488 Tyton Rubber-250Mm ( 10 ) 489 Tyton Rubber-350Mm ( 14 ) 490 Tyton Rubber-400Mm ( 16 ) 491 Tyton Rubber-500Mm ( 20 ) 492 Tyton Rubber-700Mm ( 28 ) 493 Tyton Rubber-750Mm ( 30 ) 494 Connection Clamp With Nut Bolt-2X1 / 2 495 Connection Clamp With Nut Bolt-3X1 / 2 496 Connection Clamp With Nut Bolt-4X1 / 2 497 Connection Clamp With Nut Bolt-6X1 / 2 498 Connection Clamp With Nut Bolt-8X2 / 3 499 Connection Clamp With Nut Bolt-10X2 / 3 500 Connection Clamp With Nut Bolt-12X2 / 3 / 4 501 Connection Clamp With Nut Bolt-16X2 / 3 / 4 / 6 502 Connection Clamp With Nut Bolt-18X2 / 3 / 4 / 6 503 Connection Clamp With Nut Bolt-20X2 / 3 / 4 / 6 504 Connection Clamp With Nut Bolt-24X2 / 3 / 4 / 6 505 Connection Clamp With Nut Bolt-14X2 / 3 / 4 / 6 506 Sluice Valve Heavy With Gun Metal Rod Completee Isi Mark- Deepak, Arko, Maya Or Equilent -50Mm ( 2 ) 507 Sluice Valve Heavy With Gun Metal Rod Completee Isi Mark- Deepak, Arko, Maya Or Equilent-80Mm ( 3 ) 508 Sluice Valve Heavy With Gun Metal Rod Completee Isi Mark- Deepak, Arko, Maya Or Equilent-100Mm ( 4 ) 509 Sluice Valve Heavy With Gun Metal Rod Completee Isi Mark- Deepak, Arko, Maya Or Equilent-150Mm ( 6 ) 510 Sluice Valve Heavy With Gun Metal Rod Completee Isi Mark- Deepak, Arko, Maya Or Equilent -200Mm ( 8 ) 511 Sluice Valve Heavy With Gun Metal Rod Completee Isi Mark- Deepak, Arko, Maya Or Equilent -250Mm ( 10 ) 512 Sluice Valve Heavy With Gun Metal Rod Completee Isi Mark- Deepak, Arko, Maya Or Equilent-300Mm ( 12 ) 513 Sluice Valve Heavy With Gun Metal Rod Completee Isi Mark- Deepak, Arko, Maya Or Equilent-400Mm ( 16 ) 514 Sluice Valve Heavy With Gun Metal Rod Completee Isi Mark- Deepak, Arko, Maya Or Equilent-450Mm ( 18 ) 515 Sluice Valve Heavy With Gun Metal Rod Completee Isi Mark- Deepak, Arko, Maya Or Equilent-500Mm ( 20 ) 516 Sluice Valve Heavy With Gun Metal Rod Completee Isi Mark- Deepak, Agro, Maya Or Equilent-600Mm ( 24 ) 517 Sluice Valve Heavy With Gun Metal Rod Completee Isi Mark- Deepak, Agro, Maya Or Equilent-350Mm ( 14 ) 518 C.I. Flexible Coller Coupling, Giffy Joint Heavy-150Mm ( 6 ) 519 C.I. Flexible Coller Coupling, Giffy Joint Heavy-200Mm ( 8 ) 520 C.I. Flexible Coller Coupling, Giffy Joint Heavy-250Mm ( 10 ) 521 C.I. Flexible Coller Coupling, Giffy Joint Heavy-300Mm ( 12 ) 522 C.I. Flexible Coller Coupling, Giffy Joint Heavy-350Mm ( 14 ) 523 C.I. Flexible Coller Coupling, Giffy Joint Heavy-400Mm ( 16 ) 524 C.I. Flexible Coller Coupling, Giffy Joint Heavy-450Mm ( 18 ) 525 C.I. Flexible Coller Coupling, Giffy Joint Heavy-500Mm ( 20 ) 526 C.I. Flexible Coller Coupling, Giffy Joint Heavy-600Mm ( 24 ) 527 C.I. Flexible Coller Coupling, Giffy Joint Heavy-700Mm ( 28 ) 528 C.I. Flexible Coller Coupling, Giffy Joint Heavy-750Mm ( 30 ) 529 C.I. Flexible Coller Coupling, Giffy Joint Heavy-80Mm ( 3 ) 530 C.I. Flexible Coller Coupling, Giffy Joint Heavy-100Mm ( 4 ) 531 C.I. Flexible Coller Coupling, Giffy Joint Heavy-50Mm ( 2 ) 532 C.I. D Joint Complete-80Mm ( 3 ) 533 C.I. D Joint Complete-100Mm ( 4 ) 534 C.I. D Joint Complete-150Mm ( 6 ) 535 C.I. D Joint Complete-200Mm ( 8 ) 536 C.I. D Joint Complete-250Mm ( 10 ) 537 C.I. D Joint Complete-300Mm ( 12 ) 538 Road Boring At Site-80Mm ( 3 ) 539 Road Boring At Site-100Mm ( 4 ) 540 Road Boring At Site-150Mm ( 6 ) 541 C.I. Tail Piece-80Mm ( 3 ) 542 C.I. Tail Piece-100Mm ( 4 ) 543 C.I. Tail Piece-150Mm ( 6 ) 544 C.I. Tail Piece-200Mm ( 8 ) 545 C.I. Tail Piece-250Mm ( 10 ) 546 C.I. Tail Piece-300Mm ( 12 ) 547 C.I. Tail Piece-350Mm ( 14 ) 548 C.I. Tail Piece-400Mm ( 16 ) 549 C.I. Tail Piece-450Mm ( 18 ) 550 C.I. Tail Piece-500Mm ( 20 ) 551 C.I. Tail Piece-600Mm ( 24 ) 552 C.I. Tail Piece-700Mm ( 28 ) 553 C.I. Tail Piece-750Mm ( 30 ) 554 C.I. Tail Piece-900Mm ( 36 ) 555 C.I. Coller-80Mm ( 3 ) 556 C.I. Coller-100Mm ( 4 ) 557 C.I. Coller-150Mm ( 6 ) 558 C.I. Coller-200Mm ( 8 ) 559 C.I. Coller-250Mm ( 10 ) 560 C.I. Coller-300Mm ( 12 ) 561 C.I. Coller-350Mm ( 14 ) 562 C.I. Coller-400Mm ( 16 ) 563 C.I. Coller-450Mm ( 18 ) 564 C.I. Coller-500Mm ( 20 ) 565 C.I. Coller-600Mm ( 24 ) 566 C.I. Coller-700Mm ( 28 ) 567 C.I. Coller-750Mm ( 30 ) 568 C.I. Coller-900Mm ( 36 ) 569 C.I. Bend Isi Mark-150Mm ( 6 ) 570 C.I. Bend Isi Mark-200Mm ( 8 ) 571 C.I. Bend Isi Mark-250Mm ( 10 ) 572 C.I. Bend Isi Mark-300Mm ( 12 ) 573 C.I. Bend Isi Mark-350Mm ( 14 ) 574 C.I. Bend Isi Mark-400Mm ( 16 ) 575 C.I. Bend Isi Mark-450Mm ( 18 ) 576 C.I. Bend Isi Mark-500Mm ( 20 ) 577 C.I. Bend Isi Mark-600Mm ( 24 ) 578 C.I. Bend Isi Mark-80Mm ( 3 ) 579 C.I. Bend Isi Mark-100Mm ( 4 ) 580 C.I. Bend Isi Mark-700Mm ( 28 ) 581 C.I. Bend Isi Mark-750Mm ( 30 ) 582 C.I. Bend Isi Mark-900Mm ( 36 ) 583 C.I. Tee Isi Mark-150Mm ( 6 ) 584 C.I. Tee Isi Mark-200Mm ( 8 ) 585 C.I. Tee Isi Mark-250Mm ( 10 ) 586 C.I. Tee Isi Mark-300Mm ( 12 ) 587 C.I. Tee Isi Mark-350Mm ( 14 ) 588 C.I. Tee Isi Mark-400Mm ( 16 ) 589 C.I. Tee Isi Mark-450Mm ( 18 ) 590 C.I. Tee Isi Mark-500Mm ( 20 ) 591 C.I. Tee Isi Mark-600Mm ( 24 ) 592 C.I. Tee Isi Mark-80Mm ( 3 ) 593 C.I. Tee Isi Mark-100Mm ( 4 ) 594 C.I. Tee Isi Mark-700Mm ( 28 ) 595 C.I. Tee Isi Mark-750Mm ( 30 ) 596 C.I. Pipe Isi Class La Mark-150Mm ( 6 ) 597 C.I. Pipe Isi Class La Mark-200Mm ( 8 ) 598 C.I. Pipe Isi Class La Mark-250Mm ( 10 ) 599 C.I. Pipe Isi Class La Mark-300Mm ( 12 ) 600 C.I. Pipe Isi Class La Mark-350Mm ( 14 ) 601 C.I. Pipe Isi Class La Mark-400Mm ( 16 ) 602 C.I. Pipe Isi Class La Mark-450Mm ( 18 ) 603 C.I. Pipe Isi Class La Mark-500Mm ( 20 ) 604 C.I. Pipe Isi Class La Mark-600Mm ( 24 ) 605 C.I. Pipe Isi Class La Mark-700Mm ( 28 ) 606 C.I. Pipe Isi Class La Mark-750Mm ( 30 ) 607 Fawda Tata- 608 25 Hp Centrifugal Pump Set Split Casing Type 50 Meter Head Delivery 5 Suction 6- Kirloskar / Euilent Isi Mark. 609 Diesel Engine Pump Set Complete Kirloskar / Equilent Isi Mark-5 H.P. 610 Diesel Engine Pump Set Complete Kirloskar / Equilentisi Mark-10H.P 611 Diesel Engine Pump Set Complete Kirloskar / Equilentisi Mark-15 H.P. 612 Diesel Engine Pump Set Complete Kirloskar / Equilent Isi Mark-20 H.P. 613 Mono Block Pump Set Head 40 Meter Discharge 2000 Gph 5 Hp Kirloskar Or Equilent Isi Mark- 614 Mono Block Pump Set Head 60 Meter Discharge 3500 Gph 10 Hp Kirloskar Or Equilent Isi Mark 615 Mono Block Pump Set Head 80 Meter Discharge 5000 Gph 15 Hp Kirloskar Or Equilent Isi Mark 616 Mono Block Pump Set Head 80 Meter Discharge 7500 Gph 30 Hp Kirloskar Or Equilent Isi Mark 617 Chain Pully Block Spur Gear 6 Meter Chain Heavy-2 Tonn Isi Mark 618 Chain Pully Block Spur Gear 6 Meter Chain Heavy-3Tonn Isi Mark 619 Chain Pully Block Spur Gear 6 Meter Chain Heavy-5 Tonn Isi Mark 620 Contactor 3 Phase 415 Volt L&T Starter- Ml-12 621 Contactor 3 Phase 415 Volt L&T Starter- Ml-10 622 Contactor 3 Phase 415 Volt L&T Starter- Ml-4 623 Contactor 3 Phase 415 Volt L&T Starter- Ml-3 624 Contactor 3 Phase 415 Volt L&T Starter- Ml-2 625 Contactor 3 Phase 415 Volt L&T Starter- Ml-1.5 626 Power Control Switch 3 Phase L&T 415 Volt-Fn-32 627 Power Control Switch 3 Phase L&T 415 Volt-Fn-63 628 Power Control Switch 3 Phase L&T 415 Volt-Fn-100 629 Power Control Switch 3 Phase L&T 415 Volt- Fn 250 630 Power Control Switch 3 Phase L&T 415 Volt-Fn 400 631 Over Load Relay 3 Phase L&T-45-75 Amp 632 Over Load Relay 3 Phase L&T- Mn12 180-300 Amp 633 Over Load Relay 3 Phase L&T- 2-5-4.0 Amp 634 Timer 3 Phase 415 Volt L&T-Electronic Timer 3-10 Sec. 635 Timer 3 Phase 415 Volt L&T-Thermal Timer3-10 Sec. 636 Pump Moter Set 80 Meter High Head Kirloskar / Equilent Make Or Other Isi Mark-5Hp 637 Pump Moter Set 80 Meter High Head Kirloskar / Equilent Make Or Other Isi Mark-10Hp 638 Pump Moter Set 80 Meter High Head Kirloskar / Equilent Make Or Other Isi Mark-15 Hp 639 Pump Moter Set 80 Meter High Head Kirloskar / Equilent Make Or Other Isi Mark-20 Hp 640 Pump Moter Set 80 Meter High Head Kirloskar / Equilent Make Or Other Isi Mark-30 Hp 641 Spare For Starter 415 Volt L&T-Moving Contact 2500 Amp 642 Spare For Starter 415 Volt L&T-Fix Contact 2500 Amp 643 Spare For Starter 415 Volt L&T-Moving Contact 1250 Amp 644 Spare For Starter 415 Volt L&T-Fix Contact 1250 Amp 645 Spare For Starter 415 Volt L&T-Moving Contact1000 Amp 646 Spare For Starter 415 Volt L&T-Fix Contact 1000 Amp 647 Spare For Starter 415 Volt L&T-Moving Contact 800 Amp 648 Spare For Starter 415 Volt L&T-Fix Contact 800 Amp 649 Current Transformer-Amp 2500 / 2000 / 5 650 Current Transformer-Amp 1250 / 1000 / 5 651 Current Transformer-Amp1000 / 800 / 5 652 Current Transformer-Amp 1200 / 5 653 Current Transformer-Amp 1000 / 5 654 Current Transformer-Amp 800 / 5 655 Current Transformer-Amp 600 / 5 656 Current Transformer-Amp 500 / 5 657 Current Transformer-Amp 400 / 5 658 Current Transformer-Amp 200 / 5 659 Hrc Fuse 415 Volt L&T & Isi Mark-630 Amp 660 Hrc Fuse 415 Volt L&T & Isi Mark-400 Amp 661 Hrc Fuse 415 Volt L&T & Isi Mark-250 Amp 662 Hrc Fuse 415 Volt L&T & Isi Mark-200 Amp 663 Hrc Fuse 415 Volt L&T & Isi Mark-100 Amp 664 Hrc Fuse 415 Volt L&T & Isi Mark-80 Amp 665 Hrc Fuse 415 Volt L&T & Isi Mark-63 Amp 666 Hrc Fuse 415 Volt L&T & Isi Mark-50 Amp 667 Hrc Fuse 415 Volt L&T & Isi Mark-25 Amp 668 Hrc Fuse 415 Volt L&T & Isi Mark-20 Amp 669 Hrc Fuse 415 Volt L&T & Isi Mark-10 Amp 670 Hrc Fuse 415 Volt L&T & Isi Mark-6 Amp 671 Spare Point Kit For 3 Phase Starter-Ml 12 L&T 672 Spare Point Kit For 3 Phase Starter-Ml 10 L&T 673 Spare Point Kit For 3 Phase Starter-Ml 4 L&T 674 Spare Point Kit For 3 Phase Starter-Ml 3 L&T 675 Spare Point Kit For 3 Phase Starter-Ml 2 L&T 676 Synthetic Enamel Paint All Colour Asian / Berger Or Equilent 677 Alluminium Paint Asian / Berger Or Equilent 678 Snowcem 25 Kg Packing-Asian, Berger Or Equilent 679 Oil Bound Distemper-Asian, Berger Or Equilent 680 Tarpine Oil- 681 Rubber Paint-Superior Quality Isi 682 Red Oxide Paint- 683 White Cement 50 Kg Packing- Birla Or Equilent 684 Painting Brush-150Mm ( 6 ) 685 Painting Brush-125Mm ( 5 ) 686 Painting Brush-100Mm ( 4 ) 687 Painting Brush-80Mm ( 3 ) 688 Painting Brush-50Mm ( 2 ) 689 Ball Bearing Skf / Nbc Or Equilent 6323 690 Ball Bearing Skf / Nbc Or Equilent 6322 691 Ball Bearing Skf / Nbc Or Equilent 6321 692 Ball Bearing Skf / Nbc Or Equilent 6320 693 Ball Bearing Skf / Nbc Or Equilent 6318 694 Ball Bearing Skf / Nbc Or Equilent 6316 695 Ball Bearing Skf / Nbc Or Equilent 6315 696 Ball Bearing Skf / Nbc Or Equilent 6314 697 Ball Bearing Skf / Nbc Or Equilent 6312 698 Ball Bearing Skf / Nbc Or Equilent 6311 699 Ball Bearing Skf / Nbc Or Equilent 6310 700 Ball Bearing Skf / Nbc Or Equilent 6309 701 Ball Bearing Skf / Nbc Or Equilent 6308 702 Ball Bearing Skf / Nbc Or Equilent 6307 703 Ball Bearing Skf / Nbc Or Equilent 6306 704 Ball Bearing Skf / Nbc Or Equilent 6305 705 Double Ball Bearing Nbc Or Equilent 3307 706 Angular Ball Bearing Nbc Or Equilent 7222 707 Angular Ball Bearing Nbc Or Equilent 7220 708 Angular Ball Bearing Nbc Or Equilent 7215 709 Angular Ball Bearing Nbc Or Equilent 7210 710 Angular Ball Bearing Nbc Or Equilent 7309 711 Angular Ball Bearing Nbc Or Equilent 7308 712 Thrust Ball Bearing Nbc Or Equilent 51313 713 Spherical Roller Bearing 30212 Nbc Or Equilent 714 Spherical Roller Thrust Bearing-29330 E Nbc Or Equilent 715 Spherical Roller Thrust Bearing-29326 B Nbc Or Equilent 716 Spherical Roller Thrust Bearing-29328 B Nbc Or Equilent 717 Single Roller Bearing Imported / Skf- Or Equilent Crm 36 718 Single Roller Bearing Imported / Skfor Equilent Crm 34 719 Ball Bearing Skf / Nbc Or Equilent Ball Bearing-6406 720 Ball Bearing Skf / Nbc Or Equilent Ball Bearing-6407 721 Roller Bearing Skf / Nbc Or Equilent-3310 722 Roller Bearing Skf / Nbc Or Equilent 3309 723 Ball Bearingskf / Nbc Or Equilent -Ms 12½ 724 Double Roller Bearing Skf Or Equilent-22311-K 725 Single Roller Bearing Skf Or Equilent -N. 313 726 Double Roller Bearing Skf Or Equilent-22313-K 727 Double Roller Bearing Skf Or Equilent-2309 728 Double Roller Bearing Skf Or Equilent2309 K 729 Roller Bearing-6322 Skf / Nbc Or Equilent 730 Roller Bearing-6321 Skf / Nbc Or Equilent 731 Roller Bearing-6323 Skf / Nbc Or Equilent 732 Roller Bearing Skf-C.R.M. 18Skf / Nbc Or Equilent 733 Roller Bearing Skf-13½V3 Skf / Nbc Or Equilent 734 Double Ball Bearing Skf / Nbc Or Equilent-3310 735 Ball Bearing Skf / Nbc Or Equilent -6411 736 Double Roller Bearing Nbc / Skf Or Equilent -22315 737 Double Roller Bearing Nbc / Skf Or Equilent -Nu 315 738 Galvanized Sheet-3 X12 Ft. 739 Galvanized Sheet-2½ X 10 Ft. 740 Galvanized Sheet-3X6 Ft. 741 Galvanized Sheet-3X8 Ft. 742 Cement Sheet-3X12 743 Cement Sheet-2½ X 10 Ft. 744 Cement Sheet-3X6 Ft. 745 Cement Sheet-3X8 Ft. 746 J Hook- 747 Angle Iron Fencing Pole2 Meter- 748 Cementfencing Pole 2 Meter- 749 Air Circuit Breaker 3 Ph Ac 415V, 50 Hz Draw Out With Cradlemanual Operated Protection Over Load. Earth Fault Short Circuit Over Current Protection With Solid State Analog Release - S R15 Mark L&T / Cromption- Or Equilent 2500Amp 750 Air Circuit Breaker 3 Ph Ac 415V, 50 Hz Draw Out With Cradlemanual Operated Protection Over Load. Earth Fault Short Circuit Over Current Protection With Solid State Analog Release - Sr15 Mark L&T / Crompton-Or Equilent 1250Amp 751 Air Circuit Breaker 3 Ph Ac 415V, 50 Hz Draw Out With Cradlemanual Operated Protection Over Load. Earth Fault Short Circuit Over Current Protection With Solid State Analog Release - Sr15 Mark L&T / Crompton-Or Equilent 1000Amp 752 Air Circuit Breaker 3 Ph Ac 415V, 50 Hz Draw Out With Cradlemanual Operated Protection Over Load. Earthfault Short Circuit Over Current Protection With Solid State Analog Release - Sr15 Mark L&T / Crompton-Or Equilent 800Amp 753 Acb 3 Ph Ac 415 V 50Hz Fixed Manual Operated Protection Over Load Earth Short Circuit Make L&T / Crompton Or Equilent -Amp 1250 754 Acb 3 Ph Ac 415 V 50Hz Fixed Manual Operated Protection Over Load Earth Short Circuit Make L&T / Crompton Or Equilent -Amp 630 755 Moulded Case Circuit Breaker 3 Ph Ac 415V Hz Make L&T / Crompton Or Equilent -400A 756 Moulded Case Circuit Breaker 3 Ph Ac 415V Hz Make L&T / Crompton Or Equilent -630A 757 Crimpling Tool Complete For Pressing Lugs Of All Size With Die Set-Dowells Or Equilent. 758 Submersible Motor Pump Set Complete Isifor 4 Tube Well Single Phase Discharge 1000 Gph - Usha, Amul, Anchor, Amber Or Equilent-1 Hp 759 Submersible Motor Pump Set Complete Isi For 4 Tube Well Head 80 To 100 Meter Single Phase Discharge 1000 Gph - Usha, Amul, Anchor, Amber Or Equilent-2 Hp 760 Submersible Pump Motor Set Complete Isifor 4 / 5 Tube Well Head 80 To 100 Meter Single Phase Discharge Approx 1000 To 1200 Gph - Usha, Amul, Anchor, Amber Or Equilent-3 Hp 761 Submersible Pump Motor Set Complete Isifor 4 / 5 Tube Well Head 80 To 100 Meterdischarge Approx 1500 To 1600 Gph - Usha, Amul, Anchor, Amber Or Equilent-5 Hp 762 Submersible Pump Motor Set Complete Isi For 4 / 5 Tube Well Head 80 To 100 Meter Discharge Approx 1800 To 2000 Gph - Usha, Amul, Anchor, Amber Or Equilent -6 Hp 763 Submersible Pump Motor Set Complete Isi For 4 Tube Well Head 150 Meter Single Phase Discharge Approx 800Gph- Usha, Amul, Anchor, Amber Or Equilent-1 Hp 764 Submersible Pump Motor Set Complete Isi For 4 Tube Well Head 150 Meter Single Phase Discharge Approx 1000 Gph - Usha, Amul, Anchor, Amber Or Equilent-3 Hp 765 Submersible Pump Motor Set Complete Isifor 6 Tube Well Head 80 To 100 Meter Discharge Approx 1600 To 1800 Gph - Usha, Amul, Anchor, Amber Or Equilent-6 Hp 766 Submersible Pump Motor Set Complete Isifor 6 Tube Well Head80 To100 Meter Discharge Approx 2000 Gph - Usha, Amul, Anchor, Amber Or Equilent -7-5 Hp 767 Submersible Pump Motor Set Complete Isifor 6 Tube Well Head 80 To 100 Meter Discharge Approx 2200 Gph - Usha, Amul, Anchor, Amber Or Equilent-10 Hp 768 Submersible Pump Motor Set Complete Isifor 6 Tube Well Head 80 To 100 Meter Discharge Approx 2500 Gph - Usha, Amul, Anchor, Amber Or Equilent-12-5 Hp 769 Submersible Pump Motor Set Complete Isi For 6 Tube Well Head 80 To 100 Meter Discharge Approx 4000 Gph - Usha, Amul, Anchor, Amber Or Equilent-15 Hp 770 Submersible Pump Motor Set Complete Isi For 6 Tube Well Head 150 Meter Discharge Approx 1800 Gph - Usha, Amul, Anchor, Amber Or Equilent-6 Hp 771 Submersible Pump Motor Set Complete Isi For 6 Tube Well Head 150 Meter Discharge Approx 2000 Gph - Usha, Amul, Anchor, Amber Or Equilent -7-5 Hp 772 Switch Fuse Unit ( Sfu ) 3 Ph. Ac-415 V, 50 Hz. Rating- 800 Amps, F.N.800 L&T 773 Switch Fuse Unit ( Sfu ) 3 Ph. Ac-415 V, 50 Hz. Rating- 630 Amps, Fn-630 L&T 774 Switch Fuse Unit ( Sfu ) 3 Ph. Ac-415 V, 50 Hz. Rating- 400 Amps, Fn-400 L&T 775 Switch Fuse Unit ( Sfu ) 3 Ph. Ac-415 V, 50 Hz. Rating- 250 Amps, Fn-250L&T 776 Switch Fuse Unit ( Sfu ) 3 Ph. Ac-415 V, 50 Hz. Rating-200 Amps, Fn-200L&T 777 Switch Fuse Unit ( Sfu ) 3 Ph. Ac-415 V, 50 Hz. Rating-100 Amps, Fn-100 L&T 778 Power Contactor 3 Ph, Ac-415V, 50 Hz, Coil Volt- 415 / 230 V, Make L&T Rating550 Amps, Mnx-550 779 Power Contactor 3 Ph, Ac-415V, 50 Hz Coil Volt- 415 / 230 V, Make L&T Rating325 Amps, Mnx-325 780 Power Contactor 3 Ph, Ac-415V, 50 Hz Coil Volt- 415 / 230 V, Make L&T Rating110 Amps, Mnx-110 781 Bi Metallic Over Load Relay Ct Operated 3 Ph, Ac-415 V, 50 Hz Make L&T Rating- 270-450 Amps, Mn-12 Type 782 Bi Metallic Over Load Relay Ct Operated 3 Ph, Ac-415 V, 50 Hz Make L&T Rating- 180-300 Amps 783 Bi Metallic Over Load Relay Ct Operated 3 Ph, Ac-415 V, 50 Hz Make L&T Rating- 135-225 Amps 784 Phase Failure Relay Vspd-2Minilec- 785 Pump Guard Relay Minilec 2000- 786 Electronic Timer, Minilec- ( I ) Etad - 1 787 Electronic Timer, Minilec- ( Ii ) Ets - D1 788 Hrc Fuse Ac - 415 V, 50 Hz Make L&T Rating ( I ) 630 Amps, - Hn - 3- 789 Lt Capacitor Type App Leisure Paper And Be Axially, Poly Propylene Film And Um Foil Impregnated With Non Io-Degradable Impregmant As 2834 / 1986 / 13585 1994. Make L&T. Crompton, Shakti Or Equilent Ratings- ( I ) 100 Kvar ( 25X4 ) 790 Lt Capacitor Type App Leisure Paper And Be Axially, Poly Propylene Film And Um Foil Impregnated With Non Io-Degradable Impregmant As 2834 / 1986 / 13585 1994. Make L&T. Crompton, Shakti Or Equilentratings- ( Ii ) 80 Kvar ( 20X4 ) 791 Lt Capacitor Type App Leisure Paper And Be Axially, Poly Propylene Film And Um Foil Impregnated With Non Io-Degradable Impregnate As 2834 / 1986 / 13585 1994. Make L&T. Crompton, Shakti Or Equilent Ratings- ( Iii ) 60 Kvar ( 20X3 ) 792 Lt Capacitor Type App Leisure Paper And Be Axially, Poly Propylene Film And Um Foil Impregnated With Non Io-Degradable Impregnate As 2834 / 1986 / 13585 1994. Make L&T. Crompton, Shakti Or Equilentratings- ( Iv ) 40 Kvar ( 20X2 ) 793 Lt Capacital Type App Lissure Papper And Be Axiallyd, Poly Propyline Film And Um Foil Impregnatrd With Non Io-Degradable Impregmant As 2834 / 1986 / 13585 1994. Make L&T. Cromption, Shakti Or Equilentratings- ( V ) 30 Kvar ( 15X2 ) 794 Flexible Copper Cable Pvc Insulated-50 Sq Mmisi 795 Flexible Copper Cable Pvc Insulated-35 Sq Mmisi 796 Flexible Copper Cable Pvc Insulated-25 Sq Mmisi 797 Flexible Copper Cable Pvc Insulated-16 Sq Mmisi 798 No Volt Coil 415 / 230 V Mark L&T, Rating- 550 Amps, Mnx 550 799 No Volt Coil 415 / 230 V Mark L&T, Rating-325 Amps, Mnx 325 800 No Volt Coil 415 / 230 V Mark L&T, Rating-110 Amps, Mnx 110 801 No Volt Coil 415 / 230 V Mark L&T, Rating-Ml-12, 300 Amps, 802 No Volt Coil 415 / 230 V Mark L&T, Rating-200 Amps, Ml-10 803 No Volt Coil 415 / 230 V Mark L&T, Rating- 70 Amps, Ml-4 804 Spare Contact Point Kit Without No-Volt Coil Of Contactor 3 Ph.Ac, 415 V, Mark L&T, Rating.- 550 Amps, Mnx 550 805 Spare Contact Point Kit Without No-Volt Coil Of Contactor 3 Ph Ac, 415 V, Mark L&T, Rating.- 325 Amps, Mnx 325 806 Spare Contact Point Kit Without No-Volt Coil Of Contactor 3 Ph.Ac, 415 V, Mark L&T, Rating.-110 Amps, Mnx 110 807 Spare Contact Point Kit Without No-Volt Coil Of Contactor 3 Ph.Ac, 415 V, Mark L&T, Rating.- 300 Amps, Ml-12 808 Spare Contact Point Kit Without No-Volt Coil Of Contactor 3 Ph.Ac, 415 V, Mark L&T, Rating.- 200 Amps, Ml-10 809 Spare Contact Point Kit Without No-Volt Coil Of Contactor 3 Ph.Ac, 415 V, Mark L&T, Rating.- 70 Amps, Ml-4 810 Lighting Arrestor 30 Kv 10 Ka Thyrite Magne Valve Station Class Arrester Class Ii-Is: 3070 / 1993. Iec 99-4 / 1991 Make - Elpro 33Kv Electrical Station- 811 Post Insulator 33 Kv-400 Amps, 812 Post Insulator 22 Kv-200 Amps, 813 Pin Insulator 33 Kv, - 814 Disc Insulator 33 Kv- 815 Air Break Isolating Switch 33 Kv Dobule Stack Type - ( A ) Vertical Type - ( I ) 400 Amps, 816 Air Break Isolating Switch 33 Kv Dobule Stack Type - ( A ) Vertical Type - ( Ii ) 200 Amps, 817 ( B ) Rotating Type, 3 Insulator Type - ( I ) 400 Amps, 818 ( B ) Rotating Type, 3 Insulator Type - ( Ii ) 200 Amps, 819 Drop Out Fuses Complete Set Of 3 Ph 200 Amps 33 Kva Double Stack Type- 820 Drop Out Fuses 33 Kv -25 Amps, 821 Drop Out Fuses 33 Kv -20 Amps, 822 Drop Out Fuses 33 Kv -15 Amps, 823 Drop Out Fuses 33 Kv -10 Amps, 824 Drop Out Fuses 33 Kv -7.5 Amps, 825 Drop Out Fuses 33 Kv -5 Amps, 826 Spares Of Air Break Switch ( Horizontal Moving Type ) - ( I ) Moving Contact Blade- 827 Spares Of Air Break Switch ( Horizontal Moving Type ) - ( Ii ) Fix Contact Jaw- 828 Spares Of Air Break Switch ( Horizontal Moving Type ) - ( Iii ) Tinned Copper Jumpher 400 Amps, - 829 Spares Of Air Break Switch ( Horizontal Moving Type ) - ( Iv ) Jumpher Carrier - 830 Spares Of Air Break Switch ( Horizontal Moving Type ) - ( V ) Back Connector Plate. - 831 Spares Of Air Break Switch ( Horizontal Moving Type ) - ( Vi ) E.C.Copper Blade1 1 / 2X1 / 4X 40 1 / 2- 832 Spares Of Air Break Switch ( Horizontal Moving Type ) - ( Vii ) E.C.Copper Contact Element 1 1 / 4 X 1 / 8- 833 Spares Of Air Break Switch ( Horizontal Moving Type ) - ( Viii ) E.C.Copper Contact Element 1 1 / 4 X 1 / 4- 834 Spares Of D.O. Fuses. 200 Amps- 835 ( I ) Srbp Tube With Metalfitting On Both Ends. - 836 ( Ii ) Fiber Glass Tube.- 837 ( Iii ) Fix Bottom Contact.- 838 ( Iv ) Fix Bottom Contact.- 839 D.O. Operating Rod Fibre Glass 20 Ft Long In Three Section Complete.- 840 Fiber Glass Discharge Rod 33 Kv-1. 7 Mtr Complete With Pvc Insulated Copper Conductor And Fitting.- 841 Lighting Arrestor 10 Kv 10 Ka Thyrite Magne Valve Station Class Arrester Class Ii-Is: 3070 / 1993. Iec 99-4 / 1991 Make Elpro 842 Post Insulator 11 Kv-400 Amps, 843 Post Insulator 11 Kv-200 Amps, 844 Pin Insulator 11 Kv, - 845 Disc Insulator 11 Kv- 846 Air Break Isolating Switch11kv Double Stack Type - ( I ) 400 Amps, 847 Vertical Type - ( Ii ) 200 Amps, 848 Drop Out Fuses Complete Set Of 11 Kv Single Stack Type- 849 Drop Out Fuses 11 Kv -25 Amps, 850 Drop Out Fuses 11 Kv -20 Amps, 851 Drop Out Fuses 11 Kv -15 Amps, 852 Drop Out Fuses 11 Kv -10 Amps, 853 Drop Out Fuses 11 Kv -7.5 Amps, 854 Drop Out Fuses 11 Kv -5 Amps, 855 Spares Of Air Break Swich - ( I ) Moving Contact Blade- 856 Spares Of Air Break Swich - ( Ii ) Fix Contact Jaw- 857 Spares Of Air Break Swich - ( Iii ) Tinned Copper Flexible Jumpher 400 Amps, - 858 Spares Of Air Break Swich - ( Iv ) Jumpher Carrier - 859 Spares Of Air Break Swich - ( V ) Back Connector Plate. - 860 Spares Of Air Break Swich - ( Vi ) E.C.Copper Blade1 1 / 2X1 / 4X 40 1 / 2- 861 Spares Of Air Break Swich - ( Vii ) E.C.Copper Contact Element 1 1 / 4 X 1 / 8- 862 Spares Of Air Break Swich - ( Viii ) E.C.Copper Contact Element 1 1 / 4 X 1 / 4- 863 Spares Of D.O. Fuses.- ( I ) Srbp Tube With Metalfitting On Both Ends. - 864 Spares Of D.O. Fuses.- ( Ii ) Fiber Glass Tube.- 865 Spares Of D.O. Fuses.- ( Iii ) Fix Bottom Contact.- 866 Spares Of D.O. Fuses.- ( Iv ) Fix Bottom Contact.- 867 11 Kv Porcelains Transformer Bushing 155-3347-1000 Amps 868 11 Kv Porcelains Transformer Bushing 155-3347-500 Amps 869 H.V Brass Metal Part 11 Kv-1000 Amps 870 H.V Brass Metal Part 11 Kv-500 Amps 871 Selector Switch 10 Amp-For Ammeter 872 Selector Switch 10 Amp-For Voltmeter 873 Copper Lugs Ring Type-95 Mm2 874 Copper Lugs Ring Type-120 Mm2 875 H.T. Tape 876 Fiber Bushing 1000 Amp For Supporting Bus Bar- 877 T.C. Auxiliary Contact 4 Way- 878 T.C. On-Off Switch 4 Way- 879 L.T.Phase Seprator-5 Wire L.T. Line 880 L.T.Phase Seprator-4 Wire L.T. Line 881 File 12-Flat 882 File 12-Triangular 883 File 12-Round 884 File 12-Half Round 885 Ringspanner 34-36 Tapria- Or Equilent 886 Ellen Key ( Complete Set ) -All Size 887 Fuse Grip Bakelite 16 Amp- 888 Power Contact For Switch Fuse Unit- 889 Moving Contactfor Switch Fuse Unit-F.N. 800 Amp 890 Moving Contactfor Switch Fuse Unit-F.N. 400 Amp 891 Fixcontactfor Switch Fuse Unit-F.N. 800 Amp 892 Fixcontactfor Switch Fuse Unit-F.N. 400 Amp 893 Auxilary Contact For Contactor-Ml 72 / 10 894 Auxilary Contact For Contactor-550 / 325 Mhx 895 Moving Backalite For Contactor-Ml 4 896 Moving Backalite For Contactor-Ml 10 897 Moving Backalite For Contactor-Ml 12 898 Top Housing For Contactor-Ml 4 899 Top Housing For Contactor-Ml 10 900 Top Housing For Contactor-Ml 12 901 H.R.C. Fuse Bolted Type -630 Amp 902 H.R.C. Fuse Bolted Type -400 Amps, 903 H.R.C. Fuse Bolted Type -200 Amp 904 Silica Gel Breather 1 Kg- 905 Pannel / Starter Indicator Lamp & Holder- 906 Acsr Dog Conductor 65Mm2 Alluminium- 907 M.C.C.B.-32 Amp 908 M.C.C.B.-63 Amp 909 Carbonsteel Bolt With Two Nut-12X100mm 910 Carbonsteel Bolt With Two Nut-16X125 Mm 911 Copper Strip 32X5mm- 912 Copper Round Bar 8Mm- 913 33 Kv Air Breaker Switch ( Horizontal Moving Type ) -Fix Contact 914 33 Kv Air Breaker Switch ( Horizontal Moving Type ) -Moving Contact Bar 915 33 Kv Air Breaker Switch ( Link Rod ) -Fix Contact 916 33 Kv Air Breaker Switch ( Link Rod ) -Moving Contact Bar 917 33 Kv Line-U Clamp 918 33 Kv Line-Jumpher Clamp 919 Fire Extinguishers ( Complete ) -Dry Power Chemical Type 5 Kg 920 Fire Extinguishers ( Complete ) -A.B. Chemical Type 10 Kg 921 Main Isolating Contact A.C.B-1000 Amp 922 Main Isolating Contact A.C.B-1250 Amp 923 Main Isolating Contact A.C.B-2500 Amp 924 Secondaryisolating Contact ( Fixed ) -1000 Amp 925 Secondaryisolating Contact ( Fixed ) -1250 Amp 926 Secondarylsolasting Contact ( Fixed ) -2500 Amp 927 Window Cooler 18 Usha / Crompton- 928 Impeller Brass For 150 Hp Kirloskar Pump -Brass 929 Impeller For 150 Hp Kirloskar Pump -Stainless Steel 930 Kirloskarsteel Shaft 120 Hp Pump 931 Star Coupling Set For 150 Hp Pump Love Joy- 932 Star Coupling Set For 120 Hp Pump Love Joy- 933 Starter Point Set For 150 Hp Auto Transformer Starter 934 Starter Point Set For 120 Hp Auto Transformar Starter L & T- 935 Star Coupling For 150 Hp Pump Love Joy- 936 Squar Bush C-295 For 150 Hp Pump Cupling Joyfiex / Love Toy- 937 Empty Jute / Hdpe Bags ( Empty Cement Bags ) 938 Air Valve Double3 Gmdc Arko- 939 Air Valve Double4 Gmdc Arko- 940 Bench Vice For 8 Mtc- 941 Bearing Puller 10 Mtc- 942 Pulli Puller 12 Mtc- 943 Brass Bolt-5 / 8X4 944 Brass Bolt- 4 / 8X4 945 Brass Bolt- 3 / 8X4 946 Brass Nut-5 / 8 947 Brass Nut- 1 / 2 948 Brass Nut-3 / 8 949 Washer Brass-5 / 8 950 Washer Brass-1 / 2 951 Washer Brass-3 / 8 952 Brass Stud-3 / 4X6 F.T. 953 Brass Nut-3 / 4 954 Brass Washer-3 / 4 955 Centrifugal Pump Split Type With Suitable Motor Heavy Duty Discharge 1 Lac Gallon Per Hour, Head 80 Meter Impeller Brass Shaft Stainless Steel Bearing Heavy Duty Body Heavy Base Plate Coupling With Foundation Bolt Nut Heavy Duty 956 Finger Contact Point Big-Mei / Meco 957 Finger Contact Point Small-Mei / Meco 958 Finger Contact U Type Patti-Mei / Meco 959 Cotton Tape- 960 Ampere Tape- 961 Insulation Tape- 962 Oil Paper- 963 Emery Cloth- 964 Bakelite Sheet Size 1- 965 M Seal 966 Main Switch Hrc Type 200 Amp 967 Pressed Leather Sheet- 968 Rubber Bush For Coupling 15 Mm-4X5 / 8 969 Coupling Bolt All Sizes-3X1 / 2 970 Hexa Blade Double As 1 971 Hexa Frame 972 Nut Bolt Tata All Size- 973 Nut Bolt-All Size 974 Ms Washer-All Size 975 Wire Jali All Sizes-Steel 976 Rubber Sheet White All Sizes Kranti / Orient- 977 Rubber Sheet Black All Sizes Kranti / Orient- 978 Ring Spanner Set 6 To 12 -Make Jhalani, Everest 979 Fix Spanner Set 6 To 12 -Make Jhalani, Everest 980 Plier 8-Make Jhalani, Everest 981 Amp Meter 0-100 4- 982 Amp Meter 0-500 6- 983 Amp Meter 0-1000 6- 984 Amp Meter 0-2000 6- 985 60 Hp Centrifugal Pump 1470Rpm50 Meter Head Complete Set 8X6 Suction Delivery Complete Delivery Item & Starter Kirloskar Or Equilent 986 99 % Pig Lead- 987 Petroleum Jelly- 988 Transformer Oil Ehv Grade-1 R Power-For Transformer 989 Bucket Tata 12 Big Size- 990 Hemp Rope Tool 991 Lead Wool 992 60 Hp Auto Starter 415 Volt 3 Phase Induction Motor Star Delta 1440 Ram-L&T Isi Emi 993 50 Hp Auto Starter 415 Volt 3 Phase Induction Motor Star Delta 1440 Ram-L&T Isi Emi 994 40 Hp Auto Starter 415 Volt 3 Phase Induction Motor Star Delta 1440 Ram-L&T Isi Emi 995 30 Hp Auto Starter 415 Volt 3 Phase Induction Motor Star Delta 1440 Ram-L&T Isi Emi 996 20 Hp Auto Starter 415 Volt 3 Phase Induction Motor Star Delta 1440 Ram-L&T Isi Emi 997 15 Hp Auto Starter 415 Volt 3 Phase Induction Motor Star Delta 1440 Ram-L&T Isi Emi 998 Tourch, 3 Cell, Jeep Make With Cell- 999 Bench Vice- 10No. 1000 Drill Machine With Stand Size 3 Mm - 15 Mm With Drill With Set Complete-Isi 1001 New Column Pipe Dia 300Mm, Erw Steel, Flange Thickness-25Mm ( Min ) Bolt Hole Dia - 20 Mm -Length 3.0 Mtr. 1002 New Column Pipe Dia 300Mm, Erw Steel, Flange Thickness-25Mm ( Min ) Bolt Hole Dia - 20 Mm -Length 2.0 Mtr. 1003 New Column Pipe Dia 300Mm, Erw Steel, Flange Thickness-25Mm ( Min ) Bolt Hole Dia - 20 Mm -Length 1.50 Mtr. 1004 New Column Pipe Dia 300Mm, Erw Steel, Flange Thickness-25Mm ( Min ) Bolt Hole Dia - 20 Mm -Length 1.25 Mtr. 1005 New Column Pipe Dia 300Mm, Erw Steel, Flange Thickness-25Mm ( Min ) Bolt Hole Dia - 20 Mm -Length 1. Mtr. 1006 Steel Reinforced Rubber Ball Of Normex Reflux Valve Dia-250 Mm 1007 Steel Reinforced Rubber Ball Of Normex Reflux Valve Dia-300 Mm 1008 T.V.S. Bolt & Nut Dia. 12 Mm L-65- 1009 T.V.S.Stud Dia. 15 Mm L-75- 1010 Pipe Wrench 36 Rigid Type Make Everest / Tapariya- 1011 Wire Rope Forged U Clamp-Rope Dia 10Mm 1012 Wire Rope Forged U Clamp-Rope Dia 20Mm 1013 Wire Rope Forged U Clamp-Rope Dia 25Mm 1014 Wire Rope Forged U Clamp-Rope Dia 32Mm 1015 Digital Ac / Dc Clamp Meter Make Meco / Kyoritsu Or Equilent-Range Current 20 / 200 / 1000 / Amps, Voltage 0-230 / 750V 1016 Digital Ac / Dc Multimeter Model 225 Make Meco Or Equilent -Ac- 750V Ac Current :20Ac: 20 Uf R20m Ohms 1017 High Voltage Insulation Tester Make Meco / Nippen Or Equilent -2000V, 2500M Ohms 1018 High Voltage Insulation Tester Make Meco / Nippen Or Equilent -2500V, 5000M Ohms 1019 High Voltage Insulation Tester Make Meco / Nippen Or Equilent -1000V, 1000M Ohms 1020 33 Kv Current Transformer For Highest System Voltage 36 Kv Is: 2705 / 1992-Current Ratio 100 / 5Amps 1021 33 Kv Current Transformer For Highest System Voltage 36 Kv Is: 2705 / 1992-Current Ratio 200 / 5Amps 1022 Automatic Dc 30 Volt Battery Charger Current Rating 30 Amps ( Max ) Input 230Vac, 50 Hz Including Battery Box Size 4X3X1.5 & Sheet Gauge 18 And Battery Connector Tb 56 Series 8 Position- 1 ) Input Cable 3 Core With 15A 3 Pin Plug.- 2 ) Battery Charger On / Off Rocker Switch 20 Amp With Neon Indication Lamp- 3 ) Battery Charging Voltage : ( 1 ) Auto Mode :I ) Boost & Ii ) Absorption Mode :Fine Adjustment Range 25.5V To 30V Through Preset On Front Panel Iii ) Float Mode : Fine Adjustment Range 28.5V To 30V Through Preset On Front Pane ( 2 ) Manual Mode Continuously Adjustable From 26-5V To 30V Through Multiturn Pot- 4 ) Battery Charging Current : Adjustable From 10% To 100% Of Current Rating With Multitier Pot- 5 ) Protection : Against Over Load Short Circuit Over Voltage Over Temperature & Reverse Input- 6 ) Display : ( I ) Voltmeter: 31 / 2 Disit Dpm For Displaying Battery / Charger Voltage ( Ii ) Current Meter: 31 / 2 Disit Dpm For Displaying Battery / Charger- 7 ) Indication :Red Forboost Yellow For Absorption Green For Float ( Indicating Battery Fully Charged ) Red To Indicate Reverse Battery Fully Charged ) Red To Indicate Reverse Battery Connection Green For Manual & Auto Mode- 1023 Lead Acid Rechargeable Sub Station Battery Bank 2.1 Volt 20 Ah Make Exide / Amco Or Equilent 1024 Gas Mask Respirator Canister Type Housed In Body Honessed Canvas Bag And Loaded With Appropriate Chemicals To Neutralize Chlorine Up To 2% Concentration Purified Air Supply Through Air Tight D Or N Type Soft Face Mask With Full Unbreakable Visor And Quick Operatable Head Harness.- 1025 Radicon Gear Box Make Greaves Ltd Or Equilent-V 500 Ratio 50:1 1026 Radicon Gear Box Make Greaves Ltd Or Equilent-V 400 Ratio 50:1 1027 Radicon Fear Box Make Greaves Ltd Or Equilent -V 337 Ratio 70:1 1028 Mechanical Joints With Rubber Gland Suitable For Ci / Dipipes Dia -150 Mm ( 6 ) 1029 Mechanical Joints With Rubber Gland Suitable For Ci / Di Pipes Dia -200 Mm ( 8 ) 1030 Mechanical Joints With Rubber Gland Suitable For Ci / Di Pipes Dia -250 Mm ( 10 ) 1031 Mechanical Joints With Rubber Gland Suitable For Ci / Di Pipes Dia -300 Mm ( 12 ) 1032 Mechanical Joints With Rubber Gland Suitable For Ci / Di Pipes Dia -350 Mm ( 14 ) 1033 Mechanical Joints With Rubber Gland Suitable For Ci / Di Pipes Dia -400 Mm ( 16 ) 1034 Mechanical Joints With Rubber Gland Suitable For Ci / Di Pipes Dia -450 Mm ( 18 ) 1035 Mechanical Joints With Rubber Gland Suitable For Ci / Di Pipes Dia -500 Mm ( 20 ) 1036 Mechanical Joints With Rubber Gland Suitable For Ci / Di Pipes Dia -600 Mm ( 24 ) 1037 Mechanical Joints With Rubber Gland Suitable For Ci / Di Pipes Dia -700 Mm ( 28 ) 1038 Mechanical Joints With Rubber Gland Suitable For Ci / Di Pipes Dia -750 Mm ( 30 ) 1039 Mechanical Joints With Rubber Gland Suitable For Ci / Di Pipes Dia -900 Mm ( 36 ) 1040 Mechanical Joints With Rubber Gland Suitable For Ci / Di Pipes Dia -1000 Mm ( 40 ) 1041 40 Hp Submersible Pump Motor Set 4 Stage Head:50 Mtr. Discharge -2100 L.P.M. Confirming To Is: 8034-89 / Iso9001-2008-Isi 1042 Ats Pannel Fully Automatic With All Parts Like Relay, Timer, Contactor All L&T For 40 Hp Motor- 1043 Submersible Flat Cable 3X25 Sq. Mm. Is -694-Isi Finolex Or Equilent 1044 11 Kv Sub Station 4 Pipe Sub Station Structure Guarder Channels Of Sec. ( Ishc 200X100&Is Mb 100X10 ) - 1045 Transformer - 500 Kva, 11 / 0.44 Kv 3 Phase, Double Wound With Off Dyn 11 Onan Cooled With Off Load Top Changer As Per ( Bis 1026 1981 As Per Ie Rules ) -Makes Preferred Crompton / Alstom / Bhel / Kirloskar / Tesla Or Equilent, Rating-500Kv, No Load Voltage Rering ( Hv / Lv ) -11 Kv / 0.44 Kv, Winding Material-Cooper, No, Of Phases-3, Vector-Dy1, Connection On ( Hv / Lv ) -Delta Star, Frequency-50Hz, Installation-Out Door, Type Of Cooling-Onan, Temp. Rise In Oil By Thermometer-45O, In Winding Of Resistance-55O, Terminal Arrangement-, Primary-Bare, Secondary-Whether Proop Bare Bushing, Type Of Tap Changer Of Load-Off Load Tap Changer, Taps / Step On H.V.-+5%, -15% In Steps Of 1.25%, Fitting & Accessories-Shall Be Provided As Per Bis 2026:1981, Bis 2026 ( Part 1 To Iv ) -Power Transformer, Bis 3639-Acces & Fitting For Power Transformer, Bis 335-Transformer Oil, Bis 1271-Insulating Material, Bis 2099 / Bis3347-Bushings, Bis 1011 / Bis 1180-Testing Of TransformerS 1046 Vcb 11 Kv 800A 16Ka Out Door Type With Base Structure Along With 6 Nos Terminal Connections- 1047 Acb 11 Kv 250 Amps Triple With Earth Blades Operated Double Break Isolators Horizontal Pose Insulator- 1048 Pennel Board 440 V 3 Phase 50 Hz Indoor Type 1250 Amp Acb, CtS Relay. Timer, Power Control Switch, - 1049 Cable Alluminium Armoure 3X400 Sq. Mmx3½ Core- 1050 Acb Panel Unit 3 Pole 415 V, 1250 Amp, 50 Hz, Manually Operated, Draw Out With Cradle, C- Power Make L&T-5 Nos, Fitted With Various Accessories For Control, Signaling & Inter Locking L.E. Shunt Release, Under Voltage Release, Sr-15G, Micro Switch For Fault Signaling Volt & Amp Meters With Selector Switches, Reqd Alluminim Bus Bar & Cable Glands Mounted In 2.1Mx1mx1.05 Fabricated Angle Iron Frame & 16 Saw Cr Sheet Complete Fitting & Trial Testing At Site.- 1051 Supply Errecting & Commissioning Of 750 Kva, 33 / 43Kv Oil Cooled Transformer Dyn 11 Winding Material Copper, Star Deltaoff Circuit Tap Changer Paint Epoxy Completee With Trial & Testing- 1052 Supply Erecting & Commissioning Of Vacuum Circuit Breaker 36Kv, 1250 Amp 3 Phase Outdoor Type Make Crompton Or Equilent With Indoor Control Pannel Complete Fitting With Trial & Testing- 1053 Hdpe Pipe 20Mm - 6Kg / Sqcm- 1054 Hdpe Pipe 25Mm - 6Kg / Sqcm- 1055 Hdpe Pipe 32Mm6kg / Sqcm 1056 Hdpe Pipe 40Mm 6Kg / Sqcm 1057 Hdpe Pipe 50Mm 6Kg / Sqcm 1058 Pe Service Saddle Clamp With Nut Bolts Fitting & Outlet Of 20Mm Dia For Service Connection-90Mm ( 3 ) 1059 Pe Service Saddle Clamp With Nut Bolts Fitting & Outlet Of 20Mm Dia For Service Connection-110Mm ( 4 ) 1060 Pe Service Saddle Clamp With Nut Bolts Fitting & Outlet Of 20Mm Dia For Service Connection-125Mm ( 5 ) 1061 Pe Service Saddle Clamp With Nut Bolts Fitting & Outlet Of 20Mm Dia For Service Connection-160 Mm ( 6 ) 1062 Compression Male Threaded Adaptor With Elbow-15Mm ( ½ ) 1063 Compression Female Threaded Adaptor -15Mm ( ½ ) 1064 Hdpe Pipe Pe 100 6Kg Pressure Is 4984 . 1995-110Mm ( 4 ) 1065 Hdpe Pipe Pe 100 6Kg Pressure Is 4984 . 1995-160Mm ( 6 ) 1066 Hdpe Pipe Pe 80 6Kg Pressure Is 4984 . 1995-63Mm ( 2 ) 1067 Hdpe Pipe Pe 80 6Kg Pressure Is 4984 . 1995-75Mm ( 2½ ) 1068 Hdpe Pipe Pe 80 6Kg Pressure Is 4984 . 1995-90Mm ( 3 ) 1069 Hdpe Pipe Pe 80 6Kg Pressure Is 4984 . 1995-110Mm ( 4 ) 1070 Hdpe Pipe Pe 80 6Kg Pressure Is 4984 . 1995-125Mm 1071 Hdpe Pipe Pe 80 6Kg Pressure Is 4984 . 1995-140Mm 1072 Hdpe Pipe Pe 80 6Kg Pressure Is 4984 . 1995-160Mm 1073 Hdpe Pipe Pe 80 6Kg Pressure Is 4984 . 1995-180Mm 1074 Hdpe Pipe Pe 80 6Kg Pressure Is 4984 . 1995-200Mm 1075 Hdpe Pipe Pe 80 6Kg Pressure Is 4984 . 1995-225Mm 1076 Hdpe Pipe Pe 80 6Kg Pressure Is 4984 . 1995-250Mm 1077 Hdpe Detachable Joints-63Mm 1078 Hdpe Detachable Joints-75Mm 1079 Hdpe Detachable Joints-90Mm 1080 Hdpe Detachable Joints-110Mm 1081 Hdpe Detachable Joints-125Mm 1082 Hdpe Detachable Joints-140Mm 1083 Hdpe Detachable Joints-160Mm 1084 Hdpe Detachable Joints-180Mm 1085 Hdpe Detachable Joints-200Mm 1086 Hdpe Detachable Joints-225Mm 1087 Hdpe Detachable Joints-250Mm 1088 Repair Slip Coupler For Hdpe Pipe-63Mm 1089 Repair Slip Coupler For Hdpe Pipe-75Mm 1090 Repair Slip Coupler For Hdpe Pipe-90Mm 1091 Repair Slip Coupler For Hdpe Pipe-110Mm 1092 Repair Slip Coupler For Hdpe Pipe-125Mm 1093 Repair Slip Coupler For Hdpe Pipe-140Mm 1094 Repair Slip Coupler For Hdpe Pipe-160Mm 1095 Repair Slip Coupler For Hdpe Pipe-180Mm 1096 Repair Slip Coupler For Hdpe Pipe-200Mm 1097 Repair Slip Coupler For Hdpe Pipe-225Mm 1098 Repair Slip Coupler For Hdpe Pipe-250Mm 1099 Hdpe Pipe End With Fiange-110Mm 1100 Hdpe Pipe End With Fiange-125Mm 1101 Hdpe Pipe End With Fiange-140Mm 1102 Hdpe Pipe End With Fiange-160Mm 1103 Hdpe Pipe End With Fiange-180Mm 1104 Hdpe Pipe End With Fiange-200Mm 1105 Cast Iron Leak Repair Clamps With Rubber Insertion & Nut Bolts Lead / Socket Joints-80Mm ( 3 ) 1106 Cast Iron Leak Repair Clamps With Rubber Insertion & Nut Bolts Lead / Socket Joints-100Mm ( 4 ) 1107 Cast Iron Leak Repair Clamps With Rubber Insertion & Nut Bolts Lead / Socket Joints-125Mm ( 5 ) 1108 Cast Iron Leak Repair Clamps With Rubber Insertion & Nut Bolts Lead / Socket Joints-150Mm ( 6 ) 1109 Cast Iron Leak Repair Clamps With Rubber Insertion & Nut Bolts Lead / Socket Joints-200Mm ( 8 ) 1110 Cast Iron Leak Repair Clamps With Rubber Insertion & Nut Bolts Lead / Socket Joints-250Mm ( 10 ) 1111 Cast Iron Leak Repair Clamps With Rubber Insertion & Nut Bolts Lead / Socket Joints-300Mm ( 12 ) 1112 Cast Iron Leak Repair Clamps With Rubber Insertion & Nut Bolts Lead / Socket Joints-350Mm ( 14 ) 1113 Cast Iron Leak Repair Clamps With Rubber Insertion & Nut Bolts Lead / Socket Joints-400Mm ( 16 ) 1114 Cast Iron Leak Repair Clamps With Rubber Insertion & Nut Bolts Lead / Socket Joints-450Mm ( 18 ) 1115 Cast Iron Leak Repair Clamps With Rubber Insertion & Nut Bolts Lead / Socket Joints-500Mm ( 20 ) 1116 Cast Iron Leak Repair Clamps With Rubber Insertion & Nut Bolts Lead / Socket Joints-600Mm ( 24 ) 1117 Cast Iron Leak Repair Clamps With Rubber Insertion & Nut Bolts Lead / Socket Joints-700Mm ( 28 ) 1118 Cast Iron Leak Repair Clamps With Rubber Insertion & Nut Bolts Lead / Socket Joints-750Mm ( 30 ) 1119 Cast Iron Leak Repair Clamps With Rubber Insertion & Nut Bolts Lead / Socket Joints-900Mm ( 36 ) 1120 Cast Iron Leak Repair Clamps With Rubber Insertion & Nut Bolts Lead / Socket Joints-1000Mm 1121 Cast Iron Cut-N-Repair Coupling ( Long Barrel ) With Rubber Insertion & Nut Bolts-80Mm ( 3 ) 1122 Cast Iron Cut-N-Repair Coupling ( Long Barrel ) With Rubber Insertion & Nut Bolts-100Mm ( 4 ) 1123 Cast Iron Cut-N-Repair Coupling ( Long Barrel ) With Rubber Insertion & Nut Bolts-125Mm ( 5 ) 1124 Cast Iron Cut-N-Repair Coupling ( Long Barrel ) With Rubber Insertion & Nut Bolts-150Mm ( 6 ) 1125 Cast Iron Cut-N-Repair Coupling ( Long Barrel ) With Rubber Insertion & Nut Bolts-200Mm ( 8 ) 1126 Cast Iron Cut-N-Repair Coupling ( Long Barrel ) With Rubber Insertion & Nut Bolts-250Mm ( 10 ) 1127 Cast Iron Cut-N-Repair Coupling ( Long Barrel ) With Rubber Insertion & Nut Bolts-300Mm ( 12 ) 1128 Cast Iron Cut-N-Repair Coupling ( Long Barrel ) With Rubber Insertion & Nut Bolts-350Mm ( 14 ) 1129 Cast Iron Cut-N-Repair Coupling ( Long Barrel ) With Rubber Insertion & Nut Bolts-400Mm ( 16 ) 1130 Cast Iron Cut-N-Repair Coupling ( Long Barrel ) With Rubber Insertion & Nut Bolts-450Mm ( 18 ) 1131 Cast Iron Cut-N-Repair Coupling ( Long Barrel ) With Rubber Insertion & Nut Bolts-500Mm ( 20 ) 1132 Cast Iron Cut-N-Repair Coupling ( Long Barrel ) With Rubber Insertion & Nut Bolts-600Mm ( 24 ) 1133 Cast Iron Cut-N-Repair Coupling ( Long Barrel ) With Rubber Insertion & Nut Bolts-700Mm ( 28 ) 1134 Cast Iron Cut-N-Repair Coupling ( Long Barrel ) With Rubber Insertion & Nut Bolts-750Mm ( 30 ) 1135 Cast Iron Dismantling Joints With Rubber Insertion & Nut Bilts-80Mm ( 3 ) 1136 Cast Iron Dismantling Joints With Rubber Insertion & Nut Bilts-100Mm ( 4 ) 1137 Cast Iron Dismantling Joints With Rubber Insertion & Nut Bilts-125Mm ( 5 ) 1138 Cast Iron Dismantling Joints With Rubber Insertion & Nut Bilts-150Mm ( 6 ) 1139 Cast Iron Dismantling Joints With Rubber Insertion & Nut Bilts-200Mm ( 8 ) 1140 Cast Iron Dismantling Joints With Rubber Insertion & Nut Bilts-250Mm ( 10 ) 1141 Cast Iron Dismantling Joints With Rubber Insertion & Nut Bilts-300Mm ( 12 ) 1142 Cast Iron Dismantling Joints With Rubber Insertion & Nut Bilts-350Mm ( 14 ) 1143 Cast Iron Dismantling Joints With Rubber Insertion & Nut Bilts-400Mm ( 16 ) 1144 Cast Iron Dismantling Joints With Rubber Insertion & Nut Bilts-450Mm ( 18 ) 1145 Cast Iron Dismantling Joints With Rubber Insertion & Nut Bilts-500Mm ( 20 ) 1146 Cast Iron Dismantling Joints With Rubber Insertion & Nut Bilts-600Mm ( 24 ) 1147 Cast Iron Dismantling Joints With Rubber Insertion & Nut Bilts-700Mm ( 28 ) 1148 Cast Iron Dismantling Joints With Rubber Insertion & Nut Bilts-750Mm ( 30 ) 1149 Cast Iron Dismantling Joints With Rubber Insertion & Nut Bilts-900Mm ( 36 ) 1150 Cast Iron Dismantling Joints With Rubber Insertion & Nut Bilts-1000Mm 1151 Cast Iron Mechanical Joint Bend Is:13382 / 9290°-80Mm ( 3 ) 1152 Cast Iron Mechanical Joint Bend Is:13382 / 9290°-100Mm ( 4 ) 1153 Cast Iron Mechanical Joint Bend Is:13382 / 9290°-150Mm ( 6 ) 1154 Cast Iron Mechanical Joint Bend Is:13382 / 9290°-200Mm ( 8 ) 1155 Cast Iron Mechanical Joint Bend Is:13382 / 9290°-250Mm ( 10 ) 1156 Cast Iron Mechanical Joint Bend Is:13382 / 9290°-300Mm ( 12 ) 1157 Cast Iron Mechanical Joint Bend Is:13382 / 9290°-350Mm ( 14 ) 1158 Cast Iron Mechanical Joint Bend Is:13382 / 9290°-400Mm ( 16 ) 1159 Cast Iron Mechanical Joint Bend Is:13382 / 9290°-450Mm ( 18 ) 1160 Cast Iron Mechanical Joint Bend Is:13382 / 9290°-500Mm ( 20 ) 1161 Cast Iron Mechanical Joint Bend Is:13382 / 9290°-600Mm ( 24 ) 1162 Cast Iron Mechanical Joint Bend Is:13382 / 9290°-700Mm ( 28 ) 1163 Cast Iron Mechanical Joint Bend Is:13382 / 9290°-750Mm ( 30 ) 1164 Cast Iron Mechanical Joint Bend Is:13382 / 9290°-900Mm ( 36 ) 1165 Cast Iron Mechanical Joint Bend Is:13382 / 9290°-1000Mm 1166 Cast Iron Mechanical Joint Bend Is:13382 / 9245°-80Mm ( 3 ) 1167 Cast Iron Mechanical Joint Bend Is:13382 / 9245°-100Mm ( 4 ) 1168 Cast Iron Mechanical Joint Bend Is:13382 / 9245°-150Mm ( 6 ) 1169 Cast Iron Mechanical Joint Bend Is:13382 / 9245°-200Mm ( 8 ) 1170 Cast Iron Mechanical Joint Bend Is:13382 / 9245°-250Mm ( 10 ) 1171 Cast Iron Mechanical Joint Bend Is:13382 / 9245°-300Mm ( 12 ) 1172 Cast Iron Mechanical Joint Bend Is:13382 / 9245°-350Mm ( 14 ) 1173 Cast Iron Mechanical Joint Bend Is:13382 / 9245°-400Mm ( 16 ) 1174 Cast Iron Mechanical Joint Bend Is:13382 / 9245°-450Mm ( 18 ) 1175 Cast Iron Mechanical Joint Bend Is:13382 / 9245°-500Mm ( 20 ) 1176 Cast Iron Mechanical Joint Bend Is:13382 / 9245°-600Mm ( 24 ) 1177 Cast Iron Mechanical Joint Bend Is:13382 / 9245°-700Mm ( 28 ) 1178 Cast Iron Mechanical Joint Bend Is:13382 / 9245°-750Mm ( 30 ) 1179 Cast Iron Mechanical Joint Bend Is:13382 / 9245°-900Mm ( 36 ) 1180 Cast Iron Mechanical Joint Bend Is:13382 / 9245°-1000Mm 1181 Cast Iron Mechanical Joint Bend Is:13382 / 9222½°-80Mm ( 3 ) 1182 Cast Iron Mechanical Joint Bend Is:13382 / 9222½°-100Mm ( 4 ) 1183 Cast Iron Mechanical Joint Bend Is:13382 / 9222½°-150Mm ( 6 ) 1184 Cast Iron Mechanical Joint Bend Is:13382 / 9222½°-200Mm ( 8 ) 1185 Cast Iron Mechanical Joint Bend Is:13382 / 9222½°-250Mm ( 10 ) 1186 Cast Iron Mechanical Joint Bend Is:13382 / 9222½°-300Mm ( 12 ) 1187 Cast Iron Mechanical Joint Bend Is:13382 / 9222½°-350Mm ( 14 ) 1188 Cast Iron Mechanical Joint Bend Is:13382 / 9222½°-400Mm ( 16 ) 1189 Cast Iron Mechanical Joint Bend Is:13382 / 9222½°-450Mm ( 18 ) 1190 Cast Iron Mechanical Joint Bend Is:13382 / 9222½°-500Mm ( 20 ) 1191 Cast Iron Mechanical Joint Bend Is:13382 / 9222½°-600Mm ( 24 ) 1192 Cast Iron Mechanical Joint Bend Is:13382 / 9222½°-700Mm ( 28 ) 1193 Cast Iron Mechanical Joint Bend Is:13382 / 9222½°-750Mm ( 30 ) 1194 Cast Iron Mechanical Joint Bend Is:13382 / 9222½°-900Mm ( 36 ) 1195 Cast Iron Mechanical Joint Bend Is:13382 / 9222½°-1000Mm 1196 Cast Iron Mechanical Joint Bend Is:13382 / 9211¼°-80Mm ( 3 ) 1197 Cast Iron Mechanical Joint Bend Is:13382 / 9211¼°-100Mm ( 4 ) 1198 Cast Iron Mechanical Joint Bend Is:13382 / 9211¼°-150Mm ( 6 ) 1199 Cast Iron Mechanical Joint Bend Is:13382 / 9211¼°-200Mm ( 8 ) 1200 Cast Iron Mechanical Joint Bend Is:13382 / 9211¼°-250Mm ( 10 ) 1201 Cast Iron Mechanical Joint Bend Is:13382 / 9211¼°-300Mm ( 12 ) 1202 Cast Iron Mechanical Joint Bend Is:13382 / 9211¼°-350Mm ( 14 ) 1203 Cast Iron Mechanical Joint Bend Is:13382 / 9211¼°-400Mm ( 16 ) 1204 Cast Iron Mechanical Joint Bend Is:13382 / 9211¼°-450Mm ( 18 ) 1205 Cast Iron Mechanical Joint Bend Is:13382 / 9211¼°-500Mm ( 20 ) 1206 Cast Iron Mechanical Joint Bend Is:13382 / 9211¼°-600Mm ( 24 ) 1207 Cast Iron Mechanical Joint Bend Is:13382 / 9211¼°-700Mm ( 28 ) 1208 Cast Iron Mechanical Joint Bend Is:13382 / 9211¼°-750Mm ( 30 ) 1209 Cast Iron Mechanical Joint Bend Is:13382 / 9211¼°-900Mm ( 36 ) 1210 Cast Iron Mechanical Joint Bend Is:13382 / 9211¼°-1000Mm 1211 Cast Iron Mechanical Joint Flange Spigot Is:13382 / 92 -80Mm ( 3 ) 1212 Cast Iron Mechanical Joint Flange Spigot Is:13382 / 92 -100Mm ( 4 ) 1213 Cast Iron Mechanical Joint Flange Spigot Is:13382 / 92 -150Mm ( 6 ) 1214 Cast Iron Mechanical Joint Flange Spigot Is:13382 / 92 -200Mm ( 8 ) 1215 Cast Iron Mechanical Joint Flange Spigot Is:13382 / 92 -250Mm ( 10 ) 1216 Cast Iron Mechanical Joint Flange Spigot Is:13382 / 92 -300Mm ( 12 ) 1217 Cast Iron Mechanical Joint Flange Spigot Is:13382 / 92 -350Mm ( 14 ) 1218 Cast Iron Mechanical Joint Flange Spigot Is:13382 / 92 -400Mm ( 16 ) 1219 Cast Iron Mechanical Joint Flange Spigot Is:13382 / 92 -450Mm ( 18 ) 1220 Cast Iron Mechanical Joint Flange Spigot Is:13382 / 92 -500Mm ( 20 ) 1221 Cast Iron Mechanical Joint Flange Spigot Is:13382 / 92 -600Mm ( 24 ) 1222 Cast Iron Mechanical Joint Flange Spigot Is:13382 / 92 -700Mm ( 28 ) 1223 Cast Iron Mechanical Joint Flange Spigot Is:13382 / 92 -750Mm ( 30 ) 1224 Cast Iron Mechanical Joint Flange Spigot Is:13382 / 92 -900Mm ( 36 ) 1225 Cast Iron Mechanical Joint Flange Spigot Is:13382 / 92 -1000Mm 1226 Cast Iron Mechanical Joint Equal Tee Is:13382 / 92 -80Mm ( 3 ) 1227 Cast Iron Mechanical Joint Equal Tee Is:13382 / 92 -100Mm ( 4 ) 1228 Cast Iron Mechanical Joint Equal Tee Is:13382 / 92 -150Mm ( 6 ) 1229 Cast Iron Mechanical Joint Equal Tee Is:13382 / 92 -200Mm ( 8 ) 1230 Cast Iron Mechanical Joint Equal Tee Is:13382 / 92 -250Mm ( 10 ) 1231 Cast Iron Mechanical Joint Equal Tee Is:13382 / 92 -300Mm ( 12 ) 1232 Cast Iron Mechanical Joint Equal Tee Is:13382 / 92 -350Mm ( 14 ) 1233 Cast Iron Mechanical Joint Equal Tee Is:13382 / 92 -400Mm ( 16 ) 1234 Cast Iron Mechanical Joint Equal Tee Is:13382 / 92 -450Mm ( 18 ) 1235 Cast Iron Mechanical Joint Equal Tee Is:13382 / 92 -500Mm ( 20 ) 1236 Cast Iron Mechanical Joint Equal Tee Is:13382 / 92 -600Mm ( 24 ) 1237 Cast Iron Mechanical Joint Equal Tee Is:13382 / 92 -700Mm ( 28 ) 1238 Cast Iron Mechanical Joint Equal Tee Is:13382 / 92 -750Mm ( 30 ) 1239 Cast Iron Mechanical Joint Equal Tee Is:13382 / 92 -900Mm ( 36 ) 1240 Cast Iron Mechanical Joint Equal Tee Is:13382 / 92 -1000Mm 1241 Cast Iron Mechanical Joint Reducer Is:13382 / 92 -200X150mm ( 8X6 ) 1242 Cast Iron Mechanical Joint Reducer Is:13382 / 92 -250X200mm ( 10X8 ) 1243 Cast Iron Mechanical Joint Reducer Is:13382 / 92 -300X250mm ( 12X10 ) 1244 Cast Iron Mechanical Joint Reducer Is:13382 / 92 -350X250mm ( 14X10 ) 1245 Cast Iron Mechanical Joint Reducer Is:13382 / 92 -400X300mm ( 16X12 ) 1246 Cast Iron Mechanical Joint Reducer Is:13382 / 92 -450X300mm ( 18X12 ) 1247 Cast Iron Mechanical Joint Reducer Is:13382 / 92 -500X400mm ( 20X16 ) 1248 Cast Iron Mechanical Joint Reducer Is:13382 / 92 -600X300mm ( 24X12 ) 1249 Cast Iron Mechanical Joint Reducer Is:13382 / 92 -700X300mm ( 28X12 ) 1250 Cast Iron Mechanical Joint Reducer Is:13382 / 92 -750X300mm ( 30X12 ) 1251 Double Action Air Valve Cast Iron Is. 14845 / 2000-50Mm ( 2 ) 1252 Double Action Air Valve Cast Iron Is. 14845 / 2000-80Mm ( 3 ) 1253 Double Action Air Valve Cast Iron Is. 14845 / 2000-110Mm ( 4 ) 1254 Double Action Air Valve Cast Iron Is. 14845 / 2000-150Mm ( 6 ) 1255 Double Action Air Valve Cast Iron Is. 14845 / 2000-200Mm ( 8 ) 1256 Cast Iron Sluice Valve As Per Is 14846 / 2000 Kirloskar Or Upadhaya-50Mm ( 2 ) 1257 Cast Iron Sluice Valve As Per Is 14846 / 2000 Kirloskar Or Upadhaya-80Mm ( 3 ) 1258 Cast Iron Sluice Valve As Per Is 14846 / 2000 Kirloskar Or Upadhaya-100Mm ( 4 ) 1259 Cast Iron Sluice Valve As Per Is 14846 / 2000 Kirloskar Or Upadhaya-150Mm ( 6 ) 1260 Cast Iron Sluice Valve As Per Is 14846 / 2000 Kirloskar Or Upadhaya-200Mm ( 8 ) 1261 Cast Iron Sluice Valve As Per Is 14846 / 2000 Kirloskar Or Upadhaya-250Mm ( 10 ) 1262 Cast Iron Sluice Valve As Per Is 14846 / 2000 Kirloskar Or Upadhaya-300Mm ( 12 ) 1263 Cast Iron Sluice Valve As Per Is 14846 / 2000 Kirloskar Or Upadhaya-350Mm ( 14 ) 1264 Cast Iron Sluice Valve As Per Is 14846 / 2000 Kirloskar Or Upadhaya-400Mm ( 16 ) 1265 Cast Iron Sluice Valve As Per Is 14846 / 2000 Kirloskar Or Upadhaya-450Mm ( 18 ) 1266 Cast Iron Sluice Valve As Per Is 14846 / 2000 Kirloskar Or Upadhaya-500Mm ( 20 ) 1267 Cast Iron Sluice Valve As Per Is 14846 / 2000 Kirloskar Or Upadhaya-600Mm ( 24 ) 1268 Cast Iron Sluice Valve As Per Is 14846 / 2000 Kirloskar Or Upadhaya-700Mm ( 28 ) 1269 Cast Iron Sluice Valve As Per Is 14846 / 2000 Kirloskar Or Upadhaya-750Mm ( 30 ) 1270 Cast Iron Sluice Valve As Per Is 14846 / 2000 Kirloskar Or Upadhaya-900Mm ( 36 ) 1271 Cast Iron Sluice Valve As Per Is 14846 / 2000 Kirloskar Or Upadhaya-1000Mm 1272 Castic Soda- 1273 Cotton Waste- 1274 Wire Rope 3 Mm For Level Gauge- 1275 Wire Rope Pulley For Leval Guage- 1276 Weight For Level Gauge- 1277 Float Valve With Ball-1 / 2 1278 Float Valve With Ball-1 1279 Water Meter Single Jet Type Magnetic Drive With Plastic Gear Is 779 -Class B Powder Conating Make Chambal-1 / 2 1280 Water Meter Multi Jet Magnetic Drive Is 779 -Class B Powder Conating Make Chambal-1 / 2 1281 Water Meter Multi Jet Magnetic Drive Is 779 -Class B Powder Conating Make Chambal-3 / 4 1282 Water Meter Multi Jet Magnetic Drive Is 779 -Class B Powder Conating Make Chambal-1 1283 Water Meter Multi Jet Magnetic Drive Is 779 -Class B Powder Conating Make Chambal-1-1 / 2 1284 Water Meter Multi Jet Magnetic Drive Is 779 -Class B Powder Conating Make Chambal-2 1285 Water Meter Flange Type Industrial C.I. Body Class B Removable Mechanism Type Iso Certified MakeChambal Or Dashmesh-2 1286 Water Meter Flange Type Industrial C.I. Body Class B Removable Mechanism Type Iso Certified MakeChambal Or Dashmesh-3 1287 Water Meter Flange Type Industrial C.I. Body Class B Removable Mechanism Type Iso Certified MakeChambal Or Dashmesh-4 1288 Water Meter Flange Type Industrial C.I. Body Class B Removable Mechanism Type Iso Certified MakeChambal Or Dashmesh-6 1289 Water Meter Flange Type Industrial C.I. Body Class B Removable Mechanism Type Iso Certified MakeChambal Or Dashmesh-8 1290 Water Meter Flange Type Industrial C.I. Body Class B Removable Mechanism Type Iso Certified MakeChambal Or Dashmesh-10 1291 Water Meter Flange Type Industrial C.I. Body Class B Removable Mechanism Type Iso Certified MakeChambal Or Dashmesh-12 1292 Centrifugal Monoblock Pump Sets Isi Sharp Texmo, Kirloskar-0.5 Hp 1293 Centrifugal Monoblock Pump Sets Isi Sharp Texmo, Kirloskar-1.0 Hp 1294 Centrifugal Monoblock Pump Sets Isi Sharp Texmo, Kirloskar-1.5 Hp 1295 Centrifugal Monoblock Pump Sets Isi Sharp Texmo, Kirloskar-2.0 Hp 1296 Centrifugal Monoblock Pump Sets Isi Sharp Texmo, Kirloskar-3.0 Hp 1297 Open Well Submersible Pump Set Isi Texmo, Kirloskar Or Equilent-0.5 Hp 1298 Open Well Submersible Pump Set Isi Texmo, Kirloskar Or Equilent-1.0 Hp 1299 Open Well Submersible Pump Set Isi Texmo, Kirloskar Or Equilent-1.5 Hp 1300 Open Well Submersible Pump Set Isi Texmo, Kirloskar Or Equilent-2.0 Hp 1301 Spare Ball For Air Valve-80 Mm ( 3 ) 1302 Spare Ball For Air Valve-100 Mm ( 4 ) 1303 Spare Ball For Air Valve-150 Mm ( 6 ) 1304 Spare Ball For Air Valve-200 Mm ( 8 ) 1305 Ball Valves Cast Iron H / D-1 / 2 1306 Ball Valves Cast Iron H / D-1 1307 Ball Valves Cast Iron H / D-1-1 / 2 1308 Ball Valves Cast Iron H / D-2 1309 Ball Valves Cast Iron H / D-3 1310 Fire Hose Pipe 2½-15 Mtr Roll Isi Or Equilent 1311 Fire Hose Pipe 2½-30 Mtr Roll Isi Or Equilent 1312 Allsize Elenkey ( Set ) - 1313 L.T. Copper Bus Bar Of 33 / 0.43 Kv Transformer 17X65mm X10 Mm- 1314 10Mm Heavy Duty Drill 550W 1250Rpm1.8 Kg- 1315 Z Clamp For 33 Kv Bus Bar & A.B. Switch- 1316 180Mm Speed Angle Grinder 2000W 5800 Rpm 6.9 Kg- 1317 Pressure Gauge ( 0 To 10 Kg ) - 1318 Pressure Gauge Glycerin Filled ( 0 To 10 Kg ) - 1319 1300Mm Dia Grp Coupling- 1320 1300Mm Dia Grp Bends- 1321 Hand Wheels For Various Valve- 1322 Grp Material Mekp - 1323 Ortho Resin - 1324 Cobalt- 1325 Contactor SiemenS 3Tf-50- 1326 Mccb 100 Amps L&T- 1327 Pump Shaftfor 300Hp Pump- 1328 Phase Failure Relay Vspd-3, - 1329 Phase Failure Relay Vspd-2- 1330 Hexagonal / Bihexagonal Square Drive Set.- 1331 Chain Wrench 300Mm- 1332 Tvs Nut Bolt-15X80 1333 Tvs Nut Bolt-12X80 1334 Stud With Nut-16X80 1335 Stud With Nut-21X80 1336 Cir Clip ( Big ) 80Mm- 1337 Ball Bearing 7322 Skf- 1338 Contactor Mnx-32 L&T- 1339 Et-100 Timer- 1340 Ball Bearing 319-M ( Fag ) - 1341 Auto Transformer Motor Oil Ep-90 Servo- 1342 Cable Flat Submersible25sq Mm- 1343 Bakelite Fuse Holders L&T, 415 V-20Amp 1344 Bakelite Fuse Holders L&T, 415 V-32Amp 1345 Bakelite Fuse Holders L&T, 415 V-63Amp 1346 Bakelite Fuse Holders L&T, 415 V-100Amp 1347 Switch Type Ffo, 415V-63Amp 1348 Switch Type Ffo, 415V-32Amp 1349 Rechargeable Torch 12 Volts, Dry Battery Supper Quality- 1350 Compressor Oil- 1351 Grear Oil- 1352 Putti Gloves - 1353 Chlorine Copper Pipe With Holder - 1354 Shoes / Long Boot- 1355 Helmet- 1356 Factor Meter 415 Volt- 1357 Teflon Tap- 1358 Motor Pump Set 3Hp - 1359 Motor 3Hp ( Kirloskar Make ) - 1360 Submersible Motor Pump Set 25Hp Isi - 1361 Fiber Bush With Stud And Four Nut & Washer - 1362 Fix ( Goti ) Spanner Complete Set - 8 To 32 No- 1363 Mcb -10 Amp 1364 Mcb -16 Amp 1365 Mcb -32 Amp 1366 Mcb -40 Amp 1367 Mcb -63 Amp 1368 Mcb ( Two Pole Way ) -32 Amp 1369 Mcb ( Two Pole Way ) -63 Amp 1370 Mcb ( Four Pole Way ) -32 Amp 1371 Mcb ( Four Pole Way ) -63 Amp 1372 Distribution Board ( Bus Bar ) T.P.N. Single Door Steel 4 Way Rating 200Amp- 1373 Sfu Unit-400Amps 1374 Sfu Unit-200Amps 1375 Sfu Unit-32Amps 1376 Hrc Fuse-400Amps 1377 Hrc Fuse-200Amps 1378 Hrc Fuse-32Amps 1379 Contactor Abb -A145-30 1380 Contactor Abb -A260-30 1381 Contactor Abb -A75-30 1382 Contactor Abb -A95-30 1383 Contactor Abb -A110-30 1384 Contactor Abb -A16-30-10 1385 Copper Cable -50 Sq.Mm 1386 Copper Cable -35 Sq.Mm 1387 Control Wiring 1.5 Sq.Mm- 1388 Conductor 2.5 Sq.Mm- 1389 Mpr D2 240 Vac ( Motor Protection Relay ) - 1390 Current Converter 2-5 Amps ( Range ) - 1391 Timer Ct-Yde 240 V Ac- 1392 Overload Relay Ta 110 Du 60-90A- 1393 Ct-Yde Time 240 Vac For ( Vacuum Pump ) - 1394 250A Tpn Mcb - 1395 Tpn Mcb 250A- 1396 Acetic Acid Glacial 100% ( Aldehyde Free ) Gr- 1397 Acetone For Analysis Emparta® Acs- 1398 Ammonium Carbonate Gr- 1399 Ammonium Hydrogen Difluoride Purified ( Ammonium Difluoride ) - 1400 Ammonium Monovanadate Gr- 1401 Barium Carbonate Gr- 1402 Buffer Solution Ph -Ph 2.00 1403 Buffer Solution Ph -Ph 4.00 1404 Buffer Solution Ph -Ph 7.00 1405 Buffer Solution Ph -Ph 9.00 1406 Calcium Hydroxide Gr- 1407 Chloramine T Trihydrate Gr- 1408 Chloroform Emplura®- 1409 Erichrome Black T ( C.I. No. 14645, S.No. 241 ) Indicator- 1410 Ethyl Chloroformate For Synthesis- 1411 Ferroin Indicator Solution- 1412 Hydrazinium Sulfate Gr- 1413 Hydroxylammonium Chloriede Gr- 1414 Lactic Acid Min. 88% Gr- 1415 Magnesium Carbonate Light Pure - 1416 Methyl Acetate For Synthesis- 1417 Methyl Orange ( C.I. No. 13025 S.No. 176 ) Indicator- 1418 Methyl Red ( C.I. No. 13020 S. No. 250 ) Indicator- 1419 1- Naphthol Gr- 1420 1, 10-Phenanthroline ( Monohydrate ) Gr And Redox Indicator- 1421 Phenol Red Indicatorph 6.8 - 8.4- 1422 Potassium Acetate Gr- 1423 Potassium Dichromate Emplura® - 1424 Potassium Fluoride For Analysis Emparta® Acs - 1425 Di- Potassium Hydrogen Phosphate Anhydrous For Analysis Emparta®Acs- 1426 Potassium Iodide For Analysis Emparta® Acs- 1427 Pyridine For Analysis Emparta®Acs- 1428 Pyridine For Analysis Emsure® Acs Reag. Ph.Eur.- 1429 Silver Diethyldithiocarbamate Extra Pure- 1430 Silver Sulfate Emplura®- 1431 Sodium Azide- 1432 Sodium Azide For Analysis Emparta® Acs- 1433 Sodium Chloride Gr For Analysis Acs, Iso Reag.Ph Eur.- 1434 Sodium Dichromate Dihydrate Emplura®- 1435 Sodium Dihydrogen Phosphate Dihydrate For Analysis Emsure®Reag. Ph Eur- 1436 Sodium Fluoride For Analylsis Emparta® Acs- 1437 Sodium Molybdate Pure Emplura®- 1438 Di- Sodium Tatrate Dihydrate Gr- 1439 Sulfanilic Acid For Analysis Emparta® Acs- 1440 Sulfanilic Acid Gr For Analysis Acs, Reag. Ph. Eur- 1441 5-Sulfosalicylic Acid Exra Pure- 1442 Thymol Blue Indicator- 1443 Zinc Powder Pure- 1444 Ammonium Dichromate Cryst. Pure.- 1445 Pvc.Float Valve ½ 1446 Pvc.Float Valve 1 1447 Pvc.Plumb Pipe ½ Wh S / 80 1448 Pvc.Plumb Pipe ¾ Wh S / 80 1449 Pvc.Plumb Pipe 1 Wh S / 80 1450 Pvc.Plumb Pipe 1¼ Wh S / 80 1451 Pvc.Plumb Pipe 1½ Wh S / 80 1452 Pvc.Plumb Pipe 2 Wh S / 80 1453 Pvc.Red.Bush ¾ X ½ 1454 Pvc.Red.Bush 1 ¼ X ½ 1455 Pvc.Red.Bush 1 ¼ X 1 1456 Pvc.Red.Bush 1 ½ X ½ 1457 Pvc.Red.Bush 1 ½ X ¾ 1458 Pvc.Red.Bush 1 ½ X 1 1459 Pvc.Red.Bush 1 X ½ 1460 Pvc.Red.Bush 1 X ¾ 1461 Pvc.Red.Elbow 1 X ½ 1462 Pvc.Red.Elbow 1 X ¾ 1463 Pvc.Red.Socket ¾ X ½ 1464 Pvc.Red.Tee ¾ X ½ 1465 Pvc.Red.Tee 1 X ¾ 1466 Pvc.Sh80 Compact B-Valve ½ 1467 Pvc.Sh80 Compact B-Valve ¾ 1468 Pvc.Sh80 Compact B-Valve 1 1469 Pvc.Sh80 Compact B-Valve 1¼ 1470 Pvc.Sh80 Compact B-Valve 1½ 1471 Pvc.Sh80 Compact B-Valve 2 1472 Pvc.Sh80 R.Bush 1¼X1 1473 Pvc.Sh80 R.Bush 1½X1 1474 Pvc.Sh80 R.Elbow ¾X½ 1475 Pvc.Sh80 R.Elbow 1X½ 1476 Pvc.Sh80 R.Elbow 1X¾ 1477 Pvc.Sh80 R.Elbow 1¼ X 1 1478 Pvc.Sh80 R.Socket ¾X½ 1479 Pvc.Sh80 R.Socket 1 ¼X½ 1480 Pvc.Sh80 R.Socket 1 ¼X¾ 1481 Pvc.Sh80 R.Socket 1 ¼X1 1482 Pvc.Sh80 R.Socket 1 ½X½ 1483 Pvc.Sh80 R.Socket 1 ½X¾ 1484 Pvc.Sh80 R.Socket 1 ½X1 1485 Pvc.Sh80 R.Socket 1 ½X1¼ 1486 Pvc.Sh80 R.Socket 1X½ 1487 Pvc.Sh80 R.Socket 1X¾ 1488 Pvc.Sh80 R.Socket 2X½ 1489 Pvc.Sh80 R.Socket 2X¾ 1490 Pvc.Sh80 R.Socket 2X1 ¼ 1491 Pvc.Sh80 R.Socket 2X1 ½ 1492 Pvc.Sh80 R.Socket 2X1 1493 Pvc.Sh80 R.Tee ¾X½ 1494 Pvc.Sh80 R.Tee 1X½ 1495 Pvc.Sh80 R.Tee 1X¾ 1496 Pvc.Sh80 S / Union B-Valve ½ 1497 Pvc.Sh80 S / Union B-Valve ¾ 1498 Pvc.Sh80 S / Union B-Valve 1 1499 Pvc.Sh80 S / Union B-Valve 1¼ 1500 Pvc.Sh80 S / Union B-Valve 1½ 1501 Pvc.Sh80 S / Union B-Valve 2 1502 Pvc.Sh80 Tank Nipple ½ 1503 Pvc.Sh80 Tank Nipple ¾ 1504 Pvc.Sh80 Tank Nipple 1¼ 1505 Pvc.Sh80 Tank Nipple 1½ 1506 Pvc.Sh80 Union Assy ½ 1507 Pvc.Sh80 Union Assy ¾ 1508 Pvc.Sh80 Union Assy 1 ¼ 1509 Pvc.Sh80 Union Assy 1 ½ 1510 Pvc.Sh80 Union Assy 1 1511 Pvc.Sh80 Union Assy 2 1512 Pvc.Sh80 Wh.Coupler ½ 1513 Pvc.Sh80 Wh.Coupler ¾ 1514 Pvc.Sh80 Wh.Coupler 1 ¼ 1515 Pvc.Sh80 Wh.Coupler 1 ½ 1516 Pvc.Sh80 Wh.Coupler 1 1517 Pvc.Sh80 Wh.Coupler 2 1518 Pvc.Sh80 Wh.Elbow ½ 1519 Pvc.Sh80 Wh.Elbow ¾ 1520 Pvc.Sh80 Wh.Elbow 1 ¼ 1521 Pvc.Sh80 Wh.Elbow 1 ½ 1522 Pvc.Sh80 Wh.Elbow 1 1523 Pvc.Sh80 Wh.Elbow 2 1524 Pvc.Sh80 Wh.Elbow Br.Ft. ½ 1525 Pvc.Sh80 Wh.Elbow Br.Ft. ¾ 1526 Pvc.Sh80 Wh.Elbow Br.Ft. 1 1527 Pvc.Sh80 Wh.End Cap ½ 1528 Pvc.Sh80 Wh.End Cap ¾ 1529 Pvc.Sh80 Wh.End Cap 1 ¼ 1530 Pvc.Sh80 Wh.End Cap 1 ½ 1531 Pvc.Sh80 Wh.End Cap 1 1532 Pvc.Sh80 Wh.End Cap 2 1533 Pvc.Sh80 Wh.Fta 1 ¼ 1534 Pvc.Sh80 Wh.Fta 1 ½ 1535 Pvc.Sh80 Wh.Fta 2 1536 Pvc.Sh80 Wh.Fta Br.Ft. ½ 1537 Pvc.Sh80 Wh.Fta Br.Ft. ¾ 1538 Pvc.Sh80 Wh.Fta Br.Ft. 1 1539 Pvc.Sh80 Wh.Mta 1 ¼ 1540 Pvc.Sh80 Wh.Mta 1 ½ 1541 Pvc.Sh80 Wh.Mta 2 1542 Pvc.Sh80 Wh.Mta Br.Ft. ½ 1543 Pvc.Sh80 Wh.Mta Br.Ft. ¾ 1544 Pvc.Sh80 Wh.Mta Br.Ft. 1 1545 Pvc.Sh80 Wh.Tee ½ 1546 Pvc.Sh80 Wh.Tee ¾ 1547 Pvc.Sh80 Wh.Tee 1 ¼ 1548 Pvc.Sh80 Wh.Tee 1 ½ 1549 Pvc.Sh80 Wh.Tee 1 1550 Pvc.Sh80 Wh.Tee 2 1551 Pvc.Sh80 Wh.Tee Br.Ft. ½ 1552 Pvc.Sh80 Wh.Tee Br.Ft. ¾ 1553 Pvc.Sh80 Wh.Tee Br.Ft. 1 1554 Pvc.Solvent 1 Ltr 1555 Level / Pressure Indicatormeter -Commander 150 / 240V A / Cabb 1556 ( Draw Out ) Lt Panal-10A Tpn 1557 ( Draw Out ) Lt Panal-125 A / Mcb 1558 ( Draw Out ) Lt Panal-165 A / Mcb 1559 ( Draw Out ) Lt Panal-20 A / Tpn 1560 ( Draw Out ) Lt Panal-200 A / Mcb 1561 ( Draw Out ) Lt Panal-32 A / Mcb 1562 ( Draw Out ) Lt Panal-32 A / Tpn 1563 ( Draw Out ) Lt Panal-400 A / Mcb 1564 ( Draw Out ) Lt Panal-63 4 A / Mcb 1565 ( Draw Out ) Lt Panal-63 A / Elcb 1566 ( Draw Out ) Lt Panal-Amp Meter 1567 ( Draw Out ) Lt Panal-Aux.Condectore 16 A / Ac Voltc&S 1568 ( Draw Out ) Lt Panal-Aux.Condectore 32 A / Ac Voltc&S 1569 ( Draw Out ) Lt Panal-Aux.Condectore 63 A / Ac Voltc&S 1570 ( Draw Out ) Lt Panal-Over Current Relaac Volt C&S 1571 ( Draw Out ) Lt Panal-Relay / 0.1-1.0Minillec 1572 ( Draw Out ) Lt Panal-Volt Metre 1573 1300 Mm Dia Grp Bends - 1574 1300 Mm Dia Grp Coupling - 1575 33 Kv Current Transformer-Is 2705 150 A Kalpa 1576 33 Kv Current Transformer Is 2705 75 A-Primary Therminalkalpa 1577 33 Kv Potential Transformer -36Opt , 33Kv / Rt3kalpa 1578 34 Kv Current Transformer Is 2705 75 A-Primary Connection Chamber 1579 35 Kv Current Transformer Is 2705 75 A-Flange Type Insulator 1580 36 Kv Current Transformer Is 2705 75 A-Matalic Expension Below 1581 37 Kv Current Transformer Is 2705 75 A-Secondary Therminal Box 1582 38 Kv Current Transformer Is 2705 75 A-Dome Cover 1583 A.C.B. 415 Volt-1250 A C&S 1584 A.C.B. 415 Volt-800 A 1585 Air Blowercap.220 Ltr.120 Hn-Pressure Guage Equavellent 1586 Air Blowercap.220 Ltr.120 Hn-Pully Newelgi 1587 Air Blowercap.220 Ltr.120 Hn-Safety Valve Equavellent 1588 Air Blowercap.220 Ltr.120 Hn-V-Belt Equavellent 1589 Air Blowercap.3450M3 / Hr Head 3.5 Mwc -Pully Newkayinternational 1590 Air Blowercap.3450M3 / Hr Head 3.5 Mwc -V-Belt ( Spc2800 ) 1591 Air Blowercap.3450M3 / Hrhead 3.5 Mwc -Pressure Guage 1592 Air Blowercap.3450M3 / Hrhead 3.5 Mwc -Safety Valve 1593 Air Valve 150 Mm-Newsarker 1594 Air Valve 200 Mm-Newsarker 1595 Annunciator-Audio Visual Micro Processerkrypton 1596 Area Lighting ( Sodium Vapour Lamp ) Complete Fitting ) -100 W 1597 Area Lighting ( Sodium Vapour Lamp ) Complete Fitting ) -150 W 1598 Area Lighting ( Sodium Vapour Lamp ) Complete Fitting ) -50 W Chowk 1599 Area Lighting ( Sodium Vapour Lamp ) Complete Fitting ) -50 W Ignitor 1600 Area Lighting ( Sodium Vapour Lamp ) Complete Fitting ) -50 W Lamp 1601 Ball Bearing 22214 Fag - 1602 Ball Bearing 22214 Fag -15 Hp 1603 Ball Bearing 22214 Fag -25 Hp 1604 Ball Bearing 22214 Fag -Ball Bearing For 225 Hp 1605 Capacitor -3.3 Kv 150 Kvarepcose / Equavellent 1606 Capacitor -3.3 Kv 156 Kvarmadhav 1607 Capacitor -415 V 100 Kvarepcose / Equavellent 1608 Capacitor -415 V 68 Kvarepcose / Equavellent 1609 Capacitor -60 Amp Hrc Fuse ( 3.3 Kva ) 1610 Capacitor -Bus Bar Support Insulator 1611 Chemicals-1, 10- Phenanthroline 1612 Chemicals-1-10 Phenopthlene 1613 Chemicals-42 No. Filter Paper 1614 Chemicals-43 Whatstman Filter Paper 1615 Chemicals-5-Sulfosalicylic Acid 1616 Chemicals-Acetic Acid Glacial 1617 Chemicals-Alizarine Red 5 1618 Chemicals-Aluminium Ammonium 1619 Chemicals-Amino Solution 1620 Chemicals-Ammnium Buffer Solution 1621 Chemicals-Ammonia Solution 1622 Chemicals-Ammonium Acetate 1623 Chemicals-Ammonium Acetete 1624 Chemicals-Ammonium Buffer Solution 1625 Chemicals-Ammonium Chloride 1626 Chemicals-Ammonium Hydoxide 1627 Chemicals-Ammonium Molibdate 1628 Chemicals-Arochrome Black ( T ) 1629 Chemicals-Barium Chloride 1630 Chemicals-Barrium Chloride 1631 Chemicals-Calcium Chloride 1632 Chemicals-Ebt ( Eriochrome Black-T ) 1633 Chemicals-Edta Powder 1634 Chemicals-Ethanol 1635 Chemicals-Methenol 1636 Chemicals-Ethylenediaminetetraacetic 1637 Chemicals-Glycerol 1638 Chemicals-Haxamine Gr 1639 Chemicals-Hexamethylene Tetramine 1640 Chemicals-Hydrochloric Acid Concentrated 1641 Chemicals-Hydroxyl Amine Hydrochloride 1642 Chemicals-M. Stepro Cocus Agar 1643 Chemicals-M / 7 Fc Agar 1644 Chemicals-Methanol 1645 Chemicals-Methyl Red 1646 Chemicals-Mnso4 1647 Chemicals-Nitric Acid 1648 Chemicals-Nitric Acid Concentrated 1649 Chemicals-Nuturine Ped 1650 Chemicals-Petridish 1651 Chemicals-Phenol Di Sulphonic Acid 1652 Chemicals-Phenopthlene Indicator 1653 Chemicals-Potassium Chromate 1654 Chemicals-Potassium Sodium Tartrate 1655 Chemicals-Silver Nitrate 1656 Chemicals-Sodium Acetate 1657 Chemicals-Sodium Borohydride 1658 Chemicals-Sodium Hydroxide 1659 Chemicals-Sodium Thiosulphate 1660 Chemicals-Stanous Chloride 1661 Chemicals-Starch 1662 Chemicals-Starch Soluble Extra Pure 1663 Chemicals-Sulfanilic Acid Gr 1664 Chemicals-Sulphuric Acid 98% 1665 Chemicals-Tarsan Membrane 1666 Chemicals-Toluene 1667 Chemicals-Unabsorbant Cotton 1668 Chemicals-Zinc Sulphate 1669 Chemicals-Zirconil Oxy Chliride 1670 Chlorine System- Gas Regulator Equavellent 1671 Chlorine System- Tonner Roller Equavellent 1672 Chlorine System-Caustic Pump Mod.160Ctequavellent 1673 Chlorine System-Cl2 Gas Filter Equavellent 1674 Chlorine System-Cl2 Leakage Detector Equavellent 1675 Chlorine System-Copper Tube Equavellent 1676 Chlorine System-Glass Froroted Steel Cabnet Equavellent 1677 Chlorine System-Measuring Glass ( 10 Kg ) Equavellent 1678 Chlorine System-Measuring Glass ( 15 Kg ) Equavellent 1679 Chlorine System-Pp Diaphram Valve 40 Mm Equavellent 1680 Chlorine System-Pp Diaphram Valve50 Mm Equavellent 1681 Chlorine System-Vacum Cl2 Cvr 10Ejector Typ Equavellent 1682 Chlorine System-Valve With Actuator Equavellent 1683 Chlorine System -Centrifugal Booster Pump 4 Mq At 40 Mwc Head 1684 Chlorine System -Chlorine Filter 1685 Chlorine System -Chlorine Pressure Guage 1686 Chlorine System -Copper Tube - 3 Mt 1687 Chlorine System -First Aid Box 1688 Chlorine System -First Aid Chart 1689 Chlorine System -Headerline Valve 1690 Chlorine System -Headerline With Holding 1691 Chlorine System -Leakage Detector 1692 Chlorine System -Load Indicator Of 2 Ton Capacity 1693 Chlorine System -Oxygen Kit 1694 Chlorine System -Tonner Isolation Valve 1695 Chlorine System -Tonner Rollers 1696 Chlorine System -Vaccum Feed Chlorinator Of Capacity 10 Kg 1697 Chlorine System -Y-Stainer 1698 Clairifloculator-Bridge Drive Bearing Metal Fabricator 1699 Clairifloculator-Bridge Padal Bearing 1700 Clairifloculator-Current Collecter 1701 Clairifloculator-Flocolator Gear Box ( Readycon ) 1702 Clairifloculator-Scraper Blade &Rubber 1703 Clear Water Chlorine Meter - 1704 Clear Water Ph Meter - 1705 Clear Water Turbidity Meter - 1706 Cobalt - 1707 Conductivity Type Levelswitch-Active Electrodelevcon 1708 Conductivity Type Levelswitch-Probe Head Incloser 1709 Conductivity Type Levelswitch-Refrense Electrode 1710 Conductor Cable 12 Mm- 1711 Control Panal-Add On Block No, Nc, L&T 1712 Control Panal-Annuncitore 21 240V A / C Procon 1713 Control Panal-Auxiliary Contectore 2No, 2Ncl&T 1714 Control Panal-Closing Coil 110V D / C 1715 Control Panal-Hooter 96X96 Sqmm. 240V A / Cvaishno 1716 Control Panal-Miniture Circuit Breaker Legard 1717 Control Panal-Selectore Swith 2 Pole , 2Waykaycee 1718 D Sludge Motor Pump 40 Kw -Cable Grommetneoprine 1719 D Sludge Motor Pump 40 Kw -Impeller 1720 D Sludge Motor Pump 40 Kw -Lower Ball Bearing 1721 D Sludge Motor Pump 40 Kw -Rotor Shaft 1722 D Sludge Motor Pump 40 Kw -Upper Ball Bearing 1723 D Sludge Motor Pump 40 Kw -Upper Bearing Cover 1724 Dc Battery Charger-110V Dcdb 1725 Dc Battery Charger-Aux. Card 1726 Dc Battery Charger-Batteryhbl 1727 Dc Battery Charger-Boost Relays 1728 Dc Battery Charger-Charger & Battery Shunt 1729 Dc Battery Charger-Choke 1730 Dc Battery Charger-Control Card 1731 Dc Battery Charger-Control Ckt & V. Meters Fuses / Terminals 1732 Dc Battery Charger-Control Transformer 1733 Dc Battery Charger-Diode 1734 Dc Battery Charger-F.W. Blocking Diodes 1735 Dc Battery Charger-Filter Capacitor 1736 Dc Battery Charger-Hardware 1737 Dc Battery Charger-I / P Volt Meterselect Switch 1738 Dc Battery Charger-Mother Board 1739 Dc Battery Charger-Pcb 1740 Dc Battery Charger-Power Supply Card 1741 Dc Battery Charger-R C Card 1742 Dc Battery Charger-Terminal Strip 1743 Dc Battery Charger-Time Delay Card 1744 Distance Piece 1000 Mm Dia -Joint Rubber Gaskit 1745 Distance Piece 1000 Mm Dia -New Precise Engg. 1746 Distance Piece 500 Mm Dia -Joint Rubber Gaskit 1747 Distance Piece 500 Mm Dia -New Nandamanuf 1748 Distance Piece 600 Mm Dia -Joint Rubber Gaskit 1749 Distance Piece 600 Mm Dia -New Precise Engg. 1750 Distance Piece 700 Mm Dia -Joint Rubber Gaskit Nandamanuf 1751 Distance Piece 700 Mm Dia -New 1752 Filter Media-A ) Effective Size Filter Sand 1753 Filter Media-B ) Uniformity Coefficient Sand 1754 Flow Meter-600 Ma Diasiemens 1755 Forced Water Lubrication System-Bearing 1756 Forced Water Lubrication System-Bearing Bracket 1757 Forced Water Lubrication System-Bearing Cover Packing 1758 Forced Water Lubrication System-Casing 1759 Forced Water Lubrication System-Gasket For Casing 1760 Forced Water Lubrication System-Impeller 1761 Forced Water Lubrication System-Mediadelta Project 1762 Forced Water Lubrication System-Sealing 1763 Forced Water Lubrication System-Shaft Sleve 1764 Forced Water Lubrication System-Stuffing Box 1765 Forced Water Lubrication System-Turbidity Inlet 1766 Gi Cable Tray-150 Mm 1767 Gi Cable Tray-200 Mm 1768 Gi Cable Tray-300 Mm 1769 Gi Cable Tray-450 Mm 1770 Gi Cable Tray-50 Mm 1771 Glass Fibre Met - 1772 H.T. Panal-Amp Metr. Meco 1773 H.T. Panal-B24 / 110V / 125 V Dcessun Relay 1774 H.T. Panal-Current Tranformer 3.6 / 10Kvinsutech Industries 1775 H.T. Panal-Earth Rela / 0.10.5 Essun Relay 1776 H.T. Panal-Kwh 10-120 Cohzerv 1777 H.T. Panal-Lo Volt / Hi Volt Essun Relay 1778 H.T. Panal-Rho3 1A / 5A 110 V Dcessun Relay 1779 H.T. Panal-Volt Metrdip 1780 H.T. Panal-Xr315 112V Dc Essun Relay 1781 Hand Wheels For Various Valves - 1782 Horizontal Centrifugal Pump ( 3.7 Kw ) -Impeller Becon Or Equavellent 1783 Horizontal Centrifugal Pump ( 3.7 Kw ) -Shaft Bearing Becon Or Equavellent 1784 Horizontal Centrifugal Pump ( 1.1 Kw ) -Impeller Becon Or Equavellent 1785 Horizontal Centrifugal Pump ( 1.1 Kw ) -Shaft Bearing Becon Or Equavellent 1786 Horizontal Centrifugal Pump ( 1.5 Kw ) -Impeller Becon Or Equavellent 1787 Horizontal Centrifugal Pump ( 1.5 Kw ) -Shaft Bearing Becon Or Equavellent 1788 Horizontal Centrifugal Pump ( 2.2 Kw ) -Impeller Becon Or Equavellent 1789 Horizontal Centrifugal Pump ( 2.2 Kw ) -Shaft Bearing Becon Or Equavellent 1790 Horizontal Centrifugal Pump ( 5.5 Kw ) -Impeller Becon Or Equavellent 1791 Horizontal Centrifugal Pump ( 5.5 Kw ) -Shaft Bearing Becon Or Equavellent 1792 Horizontal Centrifugal Pump 15 Mt Head 270 M3 / Hr ( 22 Kw ) -Impeller S.S. / Equavellent 1793 Horizontal Centrifugal Pump 15 Mt Head 270 M3 / Hr ( 22 Kw ) -Shaft Bearing Kirlosker Or Equavellent 1794 Horizontal Centrifugal Pump 40Mt Head ( 7.5 Kw ) -Impeller Becon Or Equavellent 1795 Horizontal Centrifugal Pump 40Mt Head ( 7.5 Kw ) -Shaft Bearing Becon Or Equavellent 1796 Horizontal Centrifugal Pump 45 Mt Head 15 Kw ) -Impeller Becon Or Equavellent 1797 Horizontal Centrifugal Pump 45 Mt Head 15 Kw ) -Shaft Bearing Becon Or Equavellent 1798 Hrcfuse 415 V L&T -10 Amp 1799 Hrcfuse 415 V L&T -100 Amp 1800 Hrcfuse 415 V L&T -12 Amp 1801 Hrcfuse 415 V L&T -150 Amp 1802 Hrcfuse 415 V L&T -16 Amp 1803 Hrcfuse 415 V L&T -20 Amp 1804 Hrcfuse 415 V L&T -200 Amp 1805 Hrcfuse 415 V L&T -25 Amp 1806 Hrcfuse 415 V L&T -250 Amp 1807 Hrcfuse 415 V L&T -32 Amp 1808 Hrcfuse 415 V L&T -400 Amp 1809 Hrcfuse 415 V L&T -50 Amp 1810 Hrcfuse 415 V L&T -6 Amp 1811 Hrcfuse 415 V L&T -63 Amp 1812 Hrcfuse 415 V L&T -70 Amp 1813 Hrcfuse 415 V L&T -8 Amp 1814 Hrcfuse 415 V L&T -80 Amp 1815 Impellers For - 215 Hp Centrifugal Pump -15 Hp 1816 Impellers For - 215 Hp Centrifugal Pump -25 Hp 1817 Indoor V.C.B. 3.6 Kva 800 A -Counter 1818 Indoor V.C.B. 3.6 Kva 800 A -Coupling 1819 Indoor V.C.B. 3.6 Kva 800 A -Diving Roller For Shutter 1820 Indoor V.C.B. 3.6 Kva 800 A -Insulating Barrier 1821 Indoor V.C.B. 3.6 Kva 800 A -Insulating Stud Assy 1822 Indoor V.C.B. 3.6 Kva 800 A -Interlock Lever 1823 Indoor V.C.B. 3.6 Kva 800 A -Lower Bush Conductor 1824 Indoor V.C.B. 3.6 Kva 800 A -Primary Disconnects 1825 Indoor V.C.B. 3.6 Kva 800 A -Socket For Multipin Plug 1826 Indoor V.C.B. 3.6 Kva 800 A -Upper Bush Conductor 1827 Indoor V.C.B. 3.6 Kva 800 A -Vaccum Interupters 1828 Indoor V.C.B. 3.6 Kva 800 A -Vk 10J13jyoti 1829 Instruments -Conductivity & Tds Meter 1830 Instruments -Distillation Apparatus 4 Lt Capacity 1831 Instruments -Hot Plate 1832 Instruments -Nutrine Pad 1833 Instruments -Petridishes50 / 17 Mm 1834 Instruments -Ph Meter 1835 Instruments -Spectophotometer 1836 Instruments -Tarsan Membrane Assembly 1837 Instruments -Tubidity Meter 1838 Instruments -Vaccume Pump 1839 Isoliating Switchhorizental Upright Solidcore Insulator Double Break Rotating Type -100 Amp, 33000 Volttopline Switchgear Pvt.Ltd 1840 Lifting Crane10 Ton -Brake Liningrewa Or Equavellent 1841 Lifting Crane10 Ton -Coil Breack Solenoid Rewa Or Equavellent 1842 Lifting Crane10 Ton -Level Switch Rewa Or Equavellent 1843 Lifting Crane10 Ton -Wire Rope Rewa Or Equavellent 1844 Lifting Crane2 Ton -Brake Liningrewa Or Equavellent 1845 Lifting Crane2 Ton -Coil Breack Solenoid Rewa Or Equavellent 1846 Lifting Crane2 Ton -Level Switch Rewa Or Equavellent 1847 Lifting Crane2 Ton -Wire Rope Rewa Or Equavellent 1848 Lifting Crane3 Ton -Brake Liningrewa Or Equavellent 1849 Lifting Crane3 Ton -Coil Breack Solenoid Rewa Or Equavellent 1850 Lifting Crane3 Ton -Level Switch Rewa Or Equavellent 1851 Lifting Crane3 Ton -Wire Rope Rewa Or Equavellent 1852 Mainhole Earthing Cover ( C I ) -450X450 1853 Metal Helide -100 W 1854 Metal Helide -150 W 1855 Metal Helide -50 W Chowk 1856 Metal Helide -50 W Ignitor 1857 Metal Helide -50 W Lamp 1858 Metal Helide -Battery Only 1859 Metal Helide -Choke 100 W 1860 Metal Helide -Choke 150 W 1861 Metal Helide -Choke 50 W 1862 Metal Helide -Solor Light12 V Complete 1863 Motor5.5 Kw 1454 Rpm -Bearing 1864 Motor5.5 Kw 1454 Rpm -Coupling Pulley 1865 Motor5.5 Kw 1454 Rpm -Terminal Plate 1866 Motor & Air Compressor Spares 55 Kw -Cable Grommet 1867 Motor & Air Compressor Spares 55 Kw -Compressor 1868 Motor & Air Compressor Spares 55 Kw -Lower Ball Bearing 1869 Motor & Air Compressor Spares 55 Kw -Moisture Sensor Provideneoprine 1870 Motor & Air Compressor Spares 55 Kw -Rotor Shaft 1871 Motor & Air Compressor Spares 55 Kw -Upper Ball Bearing 1872 Motor 1.1 Kw-Bearing 1873 Motor 1.1 Kw-Coupling Pulley 1874 Motor 1.1 Kw-Terminal Plate 1875 Motor 1.5Kw 1400 Rpm -Bearing 1876 Motor 1.5Kw 1400 Rpm -Coupling Pulley 1877 Motor 1.5Kw 1400 Rpm -Terminal Plate 1878 Motor 15 Kw-Bearing 1879 Motor 15 Kw-Pulley 1880 Motor 2.2 Kw 2830 Rpm -Bearing 1881 Motor 2.2 Kw 2830 Rpm -Coupling Pulley 1882 Motor 2.2 Kw 2830 Rpm -Terminal Platekirlosker / Upadhyay 1883 Motor 22 Kw 1470 Rpm-Bearing 1884 Motor 3.7 Kw2830rpm -Bearing 1885 Motor 3.7 Kw2830rpm -Coupling Pulley 1886 Motor 3.7 Kw2830rpm -Terminal Plate 1887 Motor 450 Kw Rpm 1000 -Cable Gland 1888 Motor 450 Kw Rpm 991 -Terminal Boxjyoti 1889 Motor 450 Kw Rpm 992 -1.Spherical Bearing De Nu324mc3skf / Equallent 1890 Motor 450 Kw Rpm 993 -2.Rollerbearing Nde, 7322Cbem 1891 Motor 450 Kw Rpm 994 -Gasket 1892 Motor 450 Kw Rpm 995 -Bush 1893 Motor 450 Kw Rpm 996 -Moisture Protector 1894 Motor 450 Kw Rpm 997 -Bottom Clamp 1895 Motor 450 Kw Rpm 999 -Cable Box 1896 Motor 500 Kw Rpm 985 -Gland Bushneoprine 1897 Motor 500 Kw Rpm 986 -1.Spherical Bearing De Nu226skf / Equallent 1898 Motor 500 Kw Rpm 987 -2.Rollerbearing Nde, Qj320 1899 Motor 500 Kw Rpm 988 -Gland Bodynylon 1900 Motor 500 Kw Rpm 989 -Terminal Sealing Plate 1901 Motor 500 Kw Rpm 990 -Temperature Rtd 1902 Motor 7.5 Kw-Bearing 1903 Motor 7.5 Kw-Terminal Plate 1904 Non Return Valve 1000 Mm-Newindian / Equvellent 1905 Non Return Valve 1300 Mm-Newindian / Equvellent 1906 Non Return Valve 600 Mm-Newindian / Equvellent 1907 Outdoor V.C.B. Breaker-3.6 Kv 630 A Jyoti 1908 Outdoor V.C.B. Breaker-Closing Coil 110 V 1909 Outdoor V.C.B. Breaker-Opening Coil 110 V 1910 Outdoor V.C.B. Breaker-Spring Charging Handle 1911 Outdoor V.C.B. Breaker-Test Therminal Box 1912 Plc Panal -16 Ch.24 V D / C Siemens 1913 Plc Panal -32 Ch.24 V D / C Siemens 1914 Plc Panal -8 Ch. 4-20 Masiemens 1915 Plc Panal -Auxiliary Contectore Siemens 1916 Plc Panal -Cpusiemens 1917 Plc Panal -Desktop Coumputor Siemens 1918 Plc Panal -Indication Lamp Siemens 1919 Plc Panal -Interface Card Siemens 1920 Plc Panal -Power Supply Siemens 1921 Plc Panal -Printerhp 1922 Plc Panal -Push Button Siemens 1923 Plc Panal -Ups 2Kvamicromax 1924 Pp Valve 40 Mm-Newhi-Tech Polymer 1925 Pp Valve 50 Mm-Newhi-Tech Polymer 1926 Pressure Gauge ( Bourden Type ) -0-1 Kg / Cm2a.N.Intrumation 1927 Pressure Gauge ( Bourden Type ) -0-10 Kg / Cm2 1928 Pressure Gauge ( Bourden Type ) -0-4 Kg / Cm2 1929 Pvc Armoured Allum. Cable-3.5Cx25 Sq.Mmpolycap 1930 Pvc Armoured Allum. Cable-3.5Cx300 Sq.Mmpolycap 1931 Pvc Armoured Allum. Cable-3.5Cx50 Sq.Mmpolycap 1932 Pvc Armoured Allum. Cable-3.5Cx95 Sq.Mmpolycap 1933 Pvc Armoured Allum. Cable-3Cx120 Sq.Mmpolycap 1934 Pvc Armoured Allum. Cable-3Cx150 Sq.Mmpolycap 1935 Pvc Armoured Allum. Cable-3Cx185 Sq.Mmpolycap 1936 Pvc Armoured Allum. Cable-3Cx4 Sq.Mmpolycap 1937 Pvc Armoured Allum. Cable-3Cx70 Sq.Mmpolycap 1938 Pvc Armoured Allum. Cable-4Cx10 Sq.Mmpolycap 1939 Pvc Armoured Allum. Cable-4Cx4 Sq.Mm 1940 Pvc Armoured Copper Cable-14Cx1.5 Sq.Mmpolycap 1941 Pvc Armoured Copper Cable-14Cx2.5 Sq.Mmpolycap 1942 Pvc Armoured Copper Cable-2Cx2.5 Sq.Mmpolycap 1943 Pvc Armoured Copper Cable-30Cx2.5 Sq.Mmpolycap 1944 Pvc Armoured Copper Cable-7Cx2.5 Sq.Mmpolycap 1945 Raw Water Ph Meter - 1946 Raw Water Turbidity Meter - 1947 Sluice Gate 1200X1200 ( C I ) -Newjash Engg Ltd. 1948 Sluice Gate 1350X1350 ( C I ) -Newjash Engg Ltd. 1949 Sluice Gate 400X400 ( C I ) -Newjash Engg Ltd. 1950 Sluice Gate 700X700 ( C I ) -Newjash Engg Ltd. 1951 Sluice Gate 800X800 ( C I ) -Newjash Engg Ltd. 1952 Sluice Valve Bross 50 Nb-Newisi 1953 Soft Starter 450 Kw-Bridge Rectrifier 1954 Soft Starter 450 Kw-Contactor ( Mx 022E / 220, 110 V ) 1955 Soft Starter 450 Kw-Control Card 1956 Soft Starter 450 Kw-Fcm Thermistore Relay Kanha 1957 Soft Starter 450 Kw-Filter Capacetor 1958 Soft Starter 450 Kw-Free Wheeling Diod 1959 Soft Starter 450 Kw-Interpoing Contector L&T 1960 Soft Starter 450 Kw-Supervisore Timer 1961 Soft Starter 450 Kw-Vaccum By Pass Devace 6.6 Kv Cgl 1962 Soft Starter 500 Kw-Bridge Rectrifier 1963 Soft Starter 500 Kw-Contactor ( Mx 022E / 220, 110 V ) 1964 Soft Starter 500 Kw-Control Card 1965 Soft Starter 500 Kw-Fcm Thermistore Relay Kanha 1966 Soft Starter 500 Kw-Filter Capacetor 1967 Soft Starter 500 Kw-Free Wheeling Diod 1968 Soft Starter 500 Kw-Interpoing Contector L&T 1969 Soft Starter 500 Kw-Supervisore Timer 1970 Soft Starter 500 Kw-Vaccum By Pass Devace 6.6 Kv Cgl 1971 Solar Invertor With Battery -1 Kw 1972 Solar Invertor With Battery -2 Kw 1973 Transformer 1250 Kva 33 / 3.6 Kv -Cable Joint Kit , Lugs 1974 Transformer 1250 Kva 33 / 3.6 Kv -Jacking Pad 1975 Transformer 1250 Kva 33 / 3.6 Kv -Oil Tank Filling Indicatore-Mco 1976 Transformer 1250 Kva 33 / 3.6 Kv -Oil Temprature Indicator 1977 Transformer 1250 Kva 33 / 3.6 Kv -Prismatic Oil Level Indicator 1978 Transformer 1250 Kva 33 / 3.6 Kv -Silicagel Breather 1979 Transformer 1250 Kva 33 / 3.6 Kv -Winding Tepreture Indicator 1980 Transformer 2000 Kva 33 / 3.6 Kv -Buckhol Relay 1981 Transformer 2000 Kva 33 / 3.6 Kv -Cable Jointer, Lugs 1982 Transformer 2000 Kva 33 / 3.6 Kv -Jacking Pad 1983 Transformer 2000 Kva 33 / 3.6 Kv -Oil Tank Filling Indicatore-Mco 1984 Transformer 2000 Kva 33 / 3.6 Kv -Oil Tempreture Indicator 1985 Transformer 2000 Kva 33 / 3.6 Kv -Prismatic Oil Level Indicator 1986 Transformer 2000 Kva 33 / 3.6 Kv -Silicagel Breather 1987 Transformer 2000 Kva 33 / 3.6 Kv -Winding Temprature Indicator 1988 Transformer 315 Kva 33 / 0.433 Kv -Cable Joint Kit , Lugs 1989 Transformer 315 Kva 33 / 0.433 Kv -Jacking Pad 1990 Transformer 315 Kva 33 / 0.433 Kv -Oil Tank Filling Indicatorknoher 1991 Transformer 315 Kva 33 / 0.433 Kv -Oil Temprature Indicator 1992 Transformer 315 Kva 33 / 0.433 Kv -Prismatic Oil Level Indicator 1993 Transformer 315 Kva 33 / 0.433 Kv -Silicagel Breather 1994 Transformer 315 Kva 33 / 0.433 Kv -Winding Tepreture Indicator 1995 Ultrasonic Transmeter -3100 Serise Rosmount 1996 Valve Actuators0.18 Kw-Contactor 24 V Dc Rotork / Auma 1997 Valve Actuators0.18 Kw-Electronic Kitrotork / Auma 1998 Valve Actuators0.18 Kw-Limit Switchrotork / Auma 1999 Valve Actuators0.18 Kw-Newrotork / Auma 2000 Valve Actuators0.36 Kw-Contactor 24 V Dc Rotork / Auma 2001 Valve Actuators0.36 Kw-Electronic Kitrotork / Auma 2002 Valve Actuators0.36 Kw-Limit Switchrotork / Auma 2003 Valve Actuators0.36 Kw-Newrotork / Auma 2004 Valve Actuators1.20 Kw-Contactor 24 V Dc Rotork / Auma 2005 Valve Actuators1.20 Kw-Electronic Kitrotork / Auma 2006 Valve Actuators1.20 Kw-Limit Switchrotork / Auma 2007 Valve Actuators1.20 Kw-Newrotork / Auma 2008 Valve Butter Fly ( F631 Disc Di ) 200 Mm-Newtyco Or Equavellent 2009 Valve Butter Fly ( F631 Disc Di ) 200 Mm-Rubber Tyco Or Equavellent 2010 Valve Butter Fly ( F631 Disc Di ) 100 Mm-Newtyco Or Equavellent 2011 Valve Butter Fly ( F631 Disc Di ) 100 Mm-Rubbertyco Or Equavellent 2012 Valve Butter Fly ( F631 Disc Di ) 1000 Mm-Newindian 2013 Valve Butter Fly ( F631 Disc Di ) 1000 Mm-Rubber Tyco Or Equavellent 2014 Valve Butter Fly ( F631 Disc Di ) 1200 Mm-Newindian 2015 Valve Butter Fly ( F631 Disc Di ) 1200 Mm-Rubber 2016 Valve Butter Fly ( F631 Disc Di ) 150 Mm-Newtyco Or Equavellent 2017 Valve Butter Fly ( F631 Disc Di ) 150 Mm-Rubber Tyco Or Equavellent 2018 Valve Butter Fly ( F631 Disc Di ) 300 Mm-Newtyco Or Equavellent 2019 Valve Butter Fly ( F631 Disc Di ) 300 Mm-Rubber Tyco Or Equavellent 2020 Valve Butter Fly ( F631 Disc Di ) 500 Mm-Newtyco Or Equavellent 2021 Valve Butter Fly ( F631 Disc Di ) 500 Mm-Rubber Tyco Or Equavellent 2022 Valve Butter Fly ( F631 Disc Di ) 600 Mm-Newtyco Or Equavellent 2023 Valve Butter Fly ( F631 Disc Di ) 600 Mm-Rubber Tyco Or Equavellent 2024 Valve Butter Fly ( F631 Disc Di ) 700 Mm-Newtyco Or Equavellent 2025 Valve Butter Fly ( F631 Disc Di ) 700 Mm-Rubber Tyco Or Equavellent 2026 Valve Butter Fly ( F631 Disc Di ) 800 Mm-Newtyco Or Equavellent 2027 Valve Butter Fly ( F631 Disc Di ) 800 Mm-Rubber Tyco Or Equavellent 2028 Vertical Turbine Pump 1818 M3 / Hr 65.34 Metr Headmodel 30 30 M / 2 Stg -80 Mm Head Shaft3 Mtr Long Flowmore 2029 Vertical Turbine Pump 1818 M3 / Hr 65.34 Metr Headmodel 30 30 M / 2 Stg -Bearing Skf / Equallent 2030 Vertical Turbine Pump 1818 M3 / Hr 65.34 Metr Headmodel 30 30 M / 2 Stg -Bearing For Discharge Caseflowmore 2031 Vertical Turbine Pump 1818 M3 / Hr 65.34 Metr Headmodel 30 30 M / 2 Stg -Bearing Retainerci 2032 Vertical Turbine Pump 1818 M3 / Hr 65.34 Metr Headmodel 30 30 M / 2 Stg -Bowl Bushflowmore 2033 Vertical Turbine Pump 1818 M3 / Hr 65.34 Metr Headmodel 30 30 M / 2 Stg -Dischare Caseflowmore 2034 Vertical Turbine Pump 1818 M3 / Hr 65.34 Metr Headmodel 30 30 M / 2 Stg -Flange Couplingm.S. 2035 Vertical Turbine Pump 1818 M3 / Hr 65.34 Metr Headmodel 30 30 M / 2 Stg -Gasketflowmore 2036 Vertical Turbine Pump 1818 M3 / Hr 65.34 Metr Headmodel 30 30 M / 2 Stg -Impellerflowmore 2037 Vertical Turbine Pump 1818 M3 / Hr 65.34 Metr Headmodel 30 30 M / 2 Stg -Impeller Keyflowmore 2038 Vertical Turbine Pump 1818 M3 / Hr 65.34 Metr Headmodel 30 30 M / 2 Stg -Line Shafts.S. 2039 Vertical Turbine Pump 1818 M3 / Hr 65.34 Metr Headmodel 30 30 M / 2 Stg -Line Shaft Bearing 2040 Vertical Turbine Pump 1818 M3 / Hr 65.34 Metr Headmodel 30 30 M / 2 Stg -Line Shaft Sleve 2041 Vertical Turbine Pump 1818 M3 / Hr 65.34 Metr Headmodel 30 30 M / 2 Stg -Shaft Coupling En-1A 2042 Vertical Turbine Pump 1818 M3 / Hr 65.34 Metr Headmodel 30 30 M / 2 Stg -Thrust Stand Assy 2043 Vertical Turbine Pump 1818 M3 / Hr 65.34 Metr Headmodel 30 30 M / 2 Stg -Top Shaft 2044 Vertical Turbine Pump 1818 M3 / Hr 65.34 Metr Headmodel 30 30 M / 2 Stg -Water Seal Ringbronze 2045 Vertical Turbine Pump 2955 M3 / Hr42.64Head Model 1P 129 -80 Mm Head Shaft3 Mtr Long Jyoti / Equavellent 2046 Vertical Turbine Pump 2955 M3 / Hr42.64Head Model 1P 130 -Strainnerjyoti / Equavellent 2047 Vertical Turbine Pump 2955 M3 / Hr42.64Head Model 1P 131 -Bottom Bearingjyoti / Equavellent 2048 Vertical Turbine Pump 2955 M3 / Hr42.64Head Model 1P 132 -Impeller Shaftjyoti / Equavellent 2049 Vertical Turbine Pump 2955 M3 / Hr42.64Head Model 1P 133 -Impellerjyoti / Equavellent 2050 Vertical Turbine Pump 2955 M3 / Hr42.64Head Model 1P 134 -Impeller Bearing Ringjyoti / Equavellent 2051 Vertical Turbine Pump 2955 M3 / Hr42.64Head Model 1P 135 -Bowl Bearing Ringjyoti / Equavellent 2052 Vertical Turbine Pump 2955 M3 / Hr42.64Head Model 1P 136 -Bowl Jyoti / Equavellent 2053 Vertical Turbine Pump 2955 M3 / Hr42.64Head Model 1P 137 -Bowl Bearing Jyoti / Equavellent 2054 Vertical Turbine Pump 2955 M3 / Hr42.64Head Model 1P 138 -Impeller Shaft Slevejyoti / Equavellent 2055 Vertical Turbine Pump 2955 M3 / Hr42.64Head Model 1P 139 -Taper Column Pipejyoti / Equavellent 2056 Vertical Turbine Pump 2955 M3 / Hr42.64Head Model 1P 140 -Line Shafts.S. / Equavellent 2057 Vertical Turbine Pump 2955 M3 / Hr42.64Head Model 1P 141 -Line Shaft Sleves.S. / Equavellent 2058 Vertical Turbine Pump 2955 M3 / Hr42.64Head Model 1P 142 -Line Shaft Bearings.S. / Equavellent 2059 Vertical Turbine Pump 2955 M3 / Hr42.64Head Model 1P 143 -Column Pipes.S. / Equavellent 2060 Vertical Turbine Pump 2955 M3 / Hr42.64Head Model 1P 144 -Discharge Pipes.S. / Equavellent 2061 Vertical Turbine Pump 2955 M3 / Hr42.64Head Model 1P 145 -Top Column Pipes.S. / Equavellent 2062 Vertical Turbine Pump 2955 M3 / Hr42.64Head Model 1P 146 -Top Shafts.S. / Equavellent 2063 Vertical Turbine Pump 2955 M3 / Hr42.64Head Model 1P 147 -Pump Bases.S. / Equavellent 2064 Vertical Turbine Pump 2955 M3 / Hr42.64Head Model 1P 148 -Stuffing Box Bearings.S. / Equavellent 2065 Vertical Turbine Pump 2955 M3 / Hr42.64Head Model 1P 150 -Motor Skirts.S. / Equavellent 2066 Vertical Turbine Pump 2955 M3 / Hr42.64Head Model 1P 151 -Ratchets.S. / Equavellent 2067 Vertical Turbine Pump 2955 M3 / Hr42.64Head Model 1P 152 -Vertical Solid Shaft Motors.S. / Equavellent 2068 Woolen Met
Contract Date : 13 Jul, 2023   |   Contract Value : 1 Crore
BRR : 9749510 Tender For Construction Of Offer Md Accommodation At Island Ground Offers Enclave Chennai; 1 Lumpsum price worked out by the tenderer for BUILDINGS AND STRUCTURES as listed in Schedule ‘A’ Part-I 2 Lumpsum price worked out by the tenderer for SITE CLEARANCE/ AREA DEVELOPMENT as listed in Schedule ‘A’ Part-II 3 Lumpsum price worked out by the tenderer for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-III 4 Lumpsum price worked out by the tenderer for INTERNAL ELECTRICSUPPLY & PVC CONDUIT as listed in Schedule ‘A’ Part-IV 5 Lumpsum price worked out by the tenderer forROAD/ PATH/ HARDSTANDING /CULVERTas listed in Schedule ‘A’ Part-V 6 Lumpsum price worked out by the tenderer for SEWAGE DISPOSAL as listed in Schedule ‘A’ Part-VI 7 Lumpsum price worked out by the tenderer for AREA DRAINAGE as listed in Schedule ‘A’ Part-VII 8 Lumpsum price worked out by the tenderer for EXTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-VIII 9 Lumpsum price worked out by the tenderer forEXTERNAL ELECTRIC SUPPLY as listed inSchedule ‘A’ Part-IX 10 Lumpsum price worked out by the tenderer forLIGHTNING PROTECTIONas listed in Schedule ‘A’ Part-X 11 Lumpsum price worked out by the tenderer for FIRE FIGHTING/ FIRE ALARM AND DETECTION as listed in Schedule ‘A’ Part-XI 12 Lumpsum price worked out by the tenderer for LIFT as listed in Schedule ‘A’ Part-XII 13 SCHEDULE A PART XIII (MISCELLANEOUS ITEMS)Note: This schedule is not pre-priced by MES 14 INTERNAL WATER SUPPLY 15 S&F for 15mm dia bore 2 way bib tap/cock fancy type, cast copper alloy chromium plated, with crutch or butterfly handle one way suitable for fixing health faucet and other for bip tap, screwed for iorn pipe or ferrule complete all as specified and directed. 16 S&F for 15mm dia bore, brass CP mixer valve 2 in 1 hot and cold water including connected with shower rose, screwed for iorn pipe or ferrule, complete all as specified and directed. 17 INTERNAL ELECTRIC SUPPLY /PVC CONDUIT 18 M&L for Point wiring complete with 1.5 sq mm single core PVC insulated FRLS unsheathed cable 1100 volts grade with multi stranded copper conductor confirming to IS-694 1990 wih ISI marked (for phase, neutral and earth) in and including stove enamelled Steel conduit with ISI Mark of minimum 20mm dia and all conduit accessories concealed including cutting/ chases in wall/ceiling/fixed to roof/truss/columns etc and including factory made branded make embossed glvanised steel pressed terminal boxes alongwith suitable size modular cover plates with frames for fixing modular switches and sockets, fan regulators etc. of suiable size modules and the earth wire to be connected to common earth dolly complete all as specified and directed for the following :- Note: Location of light points, 6 Amp socket points and light fittings may be decided by Engr-in-charge as per site/user requirment 19 One light point controlled by one modular switch 6A one way 20 One Ceiling/Exhaust fan point controlled by one modular switch 6A 21 One 3 pin socket out let6 Amps on independent board 22 One 3 pin socket out let 6 A on same board 23 One light point controlled by two 2-way switch 24 One bell/buzzer point controlled by one bell push 25 M&L for Point wiring complete all a specified with 1100 Volts grade 4 sq mm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor conforming to IS 694 1990 with ISI marked (for phase, neutral and earth)in and includingstove enamelled Steel conduit ISI Mark of minimum size 20mm dia all accessories concealed including cutting/ chases in wall/ceiling/fixed to roof/truss/columns etc and including factory made branded make embossed galvanised steel pressed terminal boxes for fixing modular sockets of suitable sizemodules and the earth wire to be connected to common earty dolly all as specified and as directed.all as specified and as directed for One three pin modular switch socket 16 amps outlet on independent board 26 S&F modular bell switch suitable type AC 240V, 6 Amps complete all as specified and directed by Engineer-in-charge. 27 Supply and Fix Modular switches suitable for type AC 240V ,6 amps 1 Module 2 way complete all as specified and directed by Engineer-in-charge. 28 Supply and Fix call bell of multi music type AC 230 volts completeall as specified and directed by Engineer-in-charge. 29 Supply and Fix wall mounted fan of double string, steel body AC single phase, 230v of size 400mm sweep with, blades frame, louvers, oscillation control knob, tilting control white colour (body and blades) complete all as specified and directed 30 Supply and Fix decorative wall light fitiing made up of polycarbonate suitable for 9 Watts Retrofit LED LampB22 Base complete all as specified and directed 31 S&F reading light (Bed Side) wall mounting5/7 W Cool day light CCT of 3000K 400Lumen output complete all as specified and directed make PhilipsCat No 31437 or equivalent in Havells or Wipro 32 ROAD/PATH /HARDSTANDING/ CULVERT 33 M & L for preparing bituminous surfaces of road and marking 2.5mm thick centre lines,edge lines ,stop lines, dashes, arrows etc. and the like n. exc 10cm wide on roads pavements with hot applied thermo plastic road marking paint of approved colour confirming to BS 3262-1989 with special applicator machine all as per manufacturers instruction complete all as specified and directed. 34 EXTERNAL WATER SUPPLY 35 Supply ,install , test and commission of Centrifugal electrically driven self priming monoblock pump set with cast iron impeller capable of pumping 350 LPM at 36 Mtr head, squirrel cage TEFC induction motor3 phase, 415V AC,50 Hz suitable for delivery 350 LPM at 36 Mtr head coupled on common base chanel including necessary PCC foundation works, nuts and bolts, copper cable from starter to motor through PVC rigid pipe ,suitable size of suction pipe not less than 20 feet or as reqd at site, Air release valve complete all as directed and specified 36 Supply and Fix Foot Valve normax type including fixingas per IS4038 all as specified and directed 65 mm DiaMake :Kirloskar,Zoloto,L&T 37 Supply, install, test and commission LT feeder piller box/ Panel board IEC -614391 , CPRI approved,indoor type IP-43 , vermin proof, dust proof , fabricated with 2 mm CRCA sheet mounted on 40x40x4mm MS angle, 3 phase 4 wire , 440 volts , AC , 50hz with TPN aluminiumbusbar of capacity100 amps with pvc insulator heat shrink colour code sleeves , mounted on procelin insulators duly prewiredcomplete volt and amp meter , selector switch with all accessories and consists of the following switch gears :-(a) Bus bar chamber with electrolytic aluminium bus bar 100 Amp capacity for 3 phase - 01 set(b) MCCB 4 pole adjustable thermal/magnetic setting ,63A, 415 V ,25 KA- 01 Nos (c) MCCB 4 pole ,32A, 415 V ,10 KA- 02 Nos (Lift & Fire Pumps)(d) MCBTP ,32A, 415 V ,10 KA- 02 Nos (Pump Sets)(f) Supply and fixing DOL starter suitable for pumping set- 02 Nos 5 HP(g) MCB SPN 6-32 Amp 10 KA -01 Nos(Pump House)(h) Digital voltmeter, Ammeter,LED phase indicator lamp, selectror switch(i) Single phase preventer- 02 Nos (j) MCB SP 32 Amps 16 KA- 1 No, Street Light Timer digital type-01 No. 38 M&L for construction of valve chamber 450x450x450 mm depth with PCC foundation in the ration 1:4:8 brick work cement mortar in the ratio 1:6 using of class B bricks , PCC coaping at the top of the ratio 1:3:6 , plastering 15 mm thick in the ratio 1:4 including MSsheet cover 3mm thick with angle iron frame 50x50x6mm locking arrengement complete with painting on steel surface with one coat of red oxide paint over two coats of synthetic enameeled paint all as specified and directed . (Earthwork shall be measured and paid seperetely in the respective items) 39 Supply and Fix Stainer Y type made of cast iron body flanged type completely fixed to line including all necessary bolts Nuts washers Etc of size 50 mm Dia Make :Kirloskar,Zoloto,L&T 40 Supply only chlorine test kitof reputed Make for testing water chlorine with all fittments and OT solution complete 41 Supply only synthetic rubber insulatedmat 2 mm thickfor voltage upto3.3 KV as per IS 15652-2006 of Size 1 meter x 2 meter x 19 mm 42 Supply testing and installation of Bleaching Dozer Bucket Type capacity 145 Litres FRP type with all fittings and fioxtures Orifice plate Drain Valve,solution dozing line (PVC) dose cantrol Valve ,Water inlet valve, air Valve any other accessories or pipe line of size upto 25 mm are included in the quoted rates all as specified and directed and supplyCHLORINE TEST KIT 43 EXTERNAL ELECTRIC SUPPLY 44 Earthing with galvanised steel earth plate electrode 60 cm x 60 cm x6 mm thick, buried directly in ground (earth pit not less than 2.25 metre below normal ground level) with top edge of earth plate not less than 1.5 metre below normal ground level connected to main earth lead GI wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of MES Schedule Part I 1991, GI earth lead protected by GI pipe 15 mm dia light grade, providing and connected to earth test point with & including necessary excavation & earth works in any type of soil, returning filling, disposal of surplus soil to 50 metre, filing with mixture of charcoal and common salt up to 15 cm above top edge of earth plate, pit of PCC 1:2:4 with precast cover of RCC 1:2:4, watering arrangement with GI funnel, 20 mm dia GI light grade watering pipe, earth test point terminal block, commissioning & testing complete. ( Note :Main earth lead beyond 7.5 metre measured and paid for separately.) 45 M/L for LT cable route indicators Oval Shaped 200x150x6 mm cast Iron precastwith engraving LT MES CABLE embedded with PCC in mix 1:3:6 type C1 incl necessary exc, returning filling & removal of soil complete as directed. 46 .Supply and fix FRP pole box of size 168X253x115mm ,thermoplastic,polycabonate,IP-66 complete with 4 pole 32 A connector, Double compression glands-2 Nos, MCB SP 6 Amps mounted with GI clamps of suitable size with nuts and bolts on street light pole all as specified 47 Material and labour for street light bracket made of 40mm GI pipe light grade 1.5 m length bent in shape for mounting street light on one end, fixing the bracket on pole with suitable GI clamps, Nus and bolts all as specified and as directed.. 48 Fabricate, supply , install, test and commission LT feeder pilar box/panle board, outdoor type, fabricated with 3.15mm CRCA sheet mounted on 50x50x6mm MS angle, 3 phase 4 wire, 440v, AC, 50 Hz, with TPN aluminium bus bar of capacity 400 Amps with pvc heat shrink colour code sleeves, mounted on porcelin insulators complete volt and amp meter , selectro switch with all accessories and consist of the following switch gear: -( Main LTpanelatPGEPT & TA ) (i) Aluminium bus bar 3 phase & neutral of capacity 300 Amps(ii) MCCB 4 Pole 200 Amps 36 KA-01 No ( Incoming) (iii) MCCB 4 Pole 160 Amps 25 KA-02 No(iv) LED phase indication lamp for 3 phase-01 No 49 Fabricate, supply , install, test and commission LT feeder pilar box/panle board, outdoor type, fabricate with 3.15mm CRCA sheet mounted on 50x50x6mm MS angle, 3 phase 4 wire, 440v, AC, 50 Hz, with TPN aluminium bus bar of capacity 400 Amps with pvc heat shrink colour code sleeves, mounted on porcelin insulators complete volt and amp meter , selectro switch with all accessories and consist of the following switch gear: -( Main LTpanel at Tower 1 ) (i) Aluminium bus bar 3 phase & neutral of capacity 300 Amps(ii) MCCB 4 Pole 160 Amps 36 KA-01 No ( Incoming) (iii) MCCB 4 Pole 100 Amps 25 KA-05 No (FF,SF,TF,FF& Pump House) (iv) MCCB 4 Pole32 Amps 16 KA- 2 No ( Ground Floor & Spare)(ix) LED phase indication lamp for 3 phase-01 No 50 Supply only synthetic rubber insulatedmat 2mm thickfor voltage upto 3.3 KV asper IS 15652-2006 of Size 1 meter x 2 meter x 19 mm 51 Provision of trenchless bore using mechanical pneumatic drilling equipment for passing electric cables through HDPE pipe of 100mm dia under the existing bituminous/WBM road/PCC hard standings, depth range not less than 1.0 mtr and upto 1.5mtr and making good to the distrubed surfaces of road to match with its existing specifications all as specified and directed by engr-in-charge at site. Note : 1. Quoted rates deems to be inclusing of necessary earth work, transportation charges of Drilling machine, and cost of HDPE pipe and passing pipe through bore complete.2. Any damage to MES/Civil assets caused during trenchless bore shall be recitfied by the contractor at his own cost.Note:The rates are inclusive for obtaining necessary permission from state/Highway authorities and any other clearances as required before starting the work 52 FIRE FIGHTING SYSTEM/ FIRE ALARAM AND DETECTION 53 Supply, installation, testing, and commissioning of Fully automatic Star Delta Starter starter, suitable for the booster pump, complete with contactors, push button, LED type indicators, auto/manual selector switch, overload protection, current sensing type single phase preventer complete with all accessories and wiring etc.with ncomplete all as specified and directed 54 M & L for fire survival cable of size 3 core 16 sq mm with strandedannaealed bare copper conductor, mica tape wrapped for heat resistance up to 950deg centigrade, GI strip wire armouredand zero halaogen outersheathed XLPE insulation cable all as directed. Make: Havells/ KEI/ RR Kabel 55 M & L for PN 1.6 rated 100 mm NB polypropelene vortex inhibitor suction lift, conforming to BS 4504 with stainless wire mesh, bolts, nuts and washers, etc. complete all as specified and directed 56 M & L for PN 1.6 rated 100 mm NB CI Y -type strainer for suction conforming to IS 907: 1984 & (Reaffirmed 2020) with SS filter screen and flange drilling standard end connection conforming to IS 1538: 2018 and necessary accessories for suction side of fire pumps complete all as specified and directed.(at pump suciton header). 57 M & L for earthing complete with galvanized steel earth plate electrode of 60 cm X 60 cm X 6 mm size, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized strip of size 32 mm X 6 mm as earth lead by means of bolts, nuts, checknuts and washers of galvanized iron or steel, galvanized iron pipe of 40 mm diameter connected to earthing test point, all as shown in electrical plate No. 5, connected to earthing test point including testing on completion, excavation, earthwork, PCC earth pit of dimensions 550 mm X 550 mm (outer) and 300 mm X 300 mm (inner) and 250 mm deep with a 10 mm deep CI cover hinged to CI frame on ground level, GI watering pipe, funnel, etc. complete all as specified and directed by the engineer-in-charge 58 M & L for Two wire addressable speaker with LED light flash/Beacon suitable for targeted announcements and equipped with a LED light flash ( to cater to hearing-impaired occupants). The unit shall be equipped with an LED that blinks in normal conditions and glows steadily upon activation. Both the control panel and speaker unit shall continuously scan for healthiness and cable connectivity to ensure integrity compliance. the speaker must have a minimum capacity of 5 watts with max voice current of 100mA. It shall have ABS housing along with Back box. it shall be able to produce 90 dB sound at 1 Mtr distance 59 M & L for remote repeater panel similar to main control panel capable of full supervision of all inputs an network integrity, having colour touch screen display, environmental adjustment control to maximise LCD legibility, LED status indicator. ( For power supply and OFF normal conditions) 60 M & L for low smoke zero halogen(LSOH) flame retardant fire alarm cable 2C x 1.5 Sqmm conforming to BS-7629-1, BS-6387 and BS EN 50200 and rated for 500V drawn through and including concealed PVC conduit and accessories of min 20mm dia NB and having plain annealed stranded copper conductor with primary insulation of glass mica fire resistant tape and secondary insulation of high performance silicon rubber, earth/drain wire of annealed tinned copper, electrostatic screen of aluminium fire barrier and type LTS3 outer sheathed conforming to BS 7655, suitable for operating temp -30 deg centigrade to +70 deg centigrade and min bending radius being six time the overall cable diameter, red in colour, including laying termination and ferruling complete all as specified and as directed 61 M&L for Firemans switch and Interconnecting with LV Switch The cost of any balance item to make MOEFA system installed under Sch A part XI above is deemed to be included in the quoted rates so as to make the system complete and fully functional ass per the prevailing engineering. 62 Supply and fixingof Mechanical foam type fire extinguishers, 9 Ltr capacity, IS:15683 : 2006, complete. 63 Supply and fixingof Dry powder ABCstoredpressuresqueezegriptypefire extinguishers, 9 kg capacity, IS:15683 : 2006, filled with ABC Mono AmmoniumPhosphatebasepowder-90completewithdischarge hose and wall mounting bracket, 2mm Mild Steel, EPDM Rubbers, Pressure Guage, which work effectively on allclass of fires (A, B, C & Electrical fires)complete. 64 Supply & fixing of 4 Nos of 9 lts capacityround bottom sand /water buckets along with round bottom type , enamel painted white inside and red outside& letter fire in black outside & handle with mounting bracket along with suitable MS stand to install the buckets as per the local fire standards 65 LIFT 66 Earthing with galvanised steel earth plate electrode 60 cm x 60 cm x3.15 mm thick, buried directly in ground (earth pit not less than 2.25 metre below normal ground level) with top edge of earth plate not less than 1.5 metre below normal ground level connected to main earth lead Copper strip 20 mmx3mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 5 of MES Schedule Part I 1991, GI earth lead protected by GI pipe 40 mm dia light grade, providing and connected to earth test point with & including necessary excavation & earth works in any type of soil, returning filling, disposal of surplus soil to 50 metre, filing with mixture of charcoal and common salt upto 15 cm above top edge of earth plate, pit of PCC 1:2:4 with precast cover of RCC 1:2:4, watering arrangement with GI funnel, 20 mm dia GI light grade watering pipe, earth test point terminal block, commissioning & testing complete. Note :Main earth lead beyond 7.5 metre measured and paid for separately.) 67 ELECTRIC CHIMNEY 68 Supply Install Testing and comissioning of Electric Chimney of size, Filterless Wall Mounted type,Operating Voltage 220 Volts 50 Hz with ,Auto Clean 3 speed cantrol gesture with 2X 1,5 LED and all other necessary fittingsand fixtures required complete all as specified and directed.Supply, erection & testing of electricalchimney with the following specificationsSize: 90 cmShape / mounting: Box / wall mountingSuction capacity : 1500-1800 cum/hrAir outlet size: 150 mmDuct size : 150 mm Duct :MOC- Stainless Steel,Duct pipe/baffle filter: inclusive as required.Motor type: BLDC motor, 240W.Blower type: MetallicLamp: 2 x 1.5 WFinish: Stainless SteelFeatures: Low Noise (less than 62 dB) steam auto cleanControls: Dual touch, multi speed option, motion sensor”.Make: Faber/ Hindware/Glen /Kaff/Cropmton 69 DG SET 70 Supply, installation, testing and commissioning of 40 KVA / 32 KW,(The capacity of Generator set shall be net after all due derating factors as per relevant lSI standard), silent Diesel engine Generating Set, 415 volts, 3 phase, 0.8 Power factor, 50 Hz, 4 wire system as per IS 10001/10002 comprising of40 KVA or equivalent, developing 1500 RPM, Water Cooled, electric start coupled toEquivalentalternator as per IS 13364 mounted on a common base frame with standard control panel for automatic starting on main control panel having meters,with emission control device as per CPCB IV + Norms and updated till date on procurement and CPCB approved acoustic enclosure suitable for ambient condition atChennai with integral fuel tank with battery and leads and accessories complete including required PCC foundation as per manufacturers instruction and confirming to conditions as per IS provisions:- 71 (A) Alternator :- Standard design alternator rated at 40 KVA net output at site after considering derating as per site conditions at 0.8 (lag) power factor AC, 3 - phase 4 - wire 415 volts 50 Hz, 1500 RPM, self excited self regulated screen protected drip proof IP 23 enclosure brushless design with winding in pole faces, insulating class H and voltage regulation of ± 1 % at rated voltage from no load to full load. The alternator shall be confirming to BS 2613/5000 and shall be imposition to generate supply with frequency regulation with in ± 1% tolerance. The alternator will be suitable for tropical climate and shall generally confirm to BS/IS – 4722 and as per the following provisions:- Make:- KIRLOSKAR/JYOTI / STAMFORD/CATERPILLAR(a) Insulation class - H(b) Temperature rise Class - H(c) Excitation: Self Excited(d) Regulation performance: The voltage is kept constant with ± 1 %, manual voltage adjustment within ± 5%(e) Frequency regulation ± 1 %(f) 2 runs of UG cable of suitable size from Alternator to AMP is deemed to be include in quoted rate. 72 (B) Diesel Engine: - Adequate capacity Diesel engine suitable for 40 KVA coupled drive independently above alternator and after considering derating as per site conditions after generating and reducing power consumed by accessories, directly coupled through flexible coupling, multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant ISI/BS - 5514 with an overload capacity of 10% for one hour in 12 hours continuous running complete with standard accessories all asspecified and required for safe handling and operation salient features of accessories shall be as under Make :- KIRLOSKAR/CUMMINS / CATERPILLAR (GEMCO) 73 (a) Fly wheel with housing (b) Cooling system :- Mounted radiator with fan & belts.(c) Cooling pump: - Centrifugal type belt driven. (d) Exhaust System :- Exhaust System complete with exhaust piping of suitable dia as per manufacture standard with MS pipe light grade up to and away two meters height from top of enclosure including necessary angle iron frame supports from floor to the bottom of exhaust pipe from the enclosure covered with mineral wool of thickness 50mm rapped with chicken wire mesh of size 2.25mm and aluminum sheet of 24 SWG to be complete with in the enclosure for safe exhaust without transforming vibration to the wall of the enclosure. Exhaust gas turbo charger type Exhaust manifold Silencer: Residential type Belows 74 (C) Fuel System :- Fuel injection system with fuel injectors, fuel injectionsolenoid switch/nozzles/ governor mechanical type capable for 1 % speed/frequency regulation.(i) Fuel filters(ii) Fuel hoses(iii) Lub oil System :-(iv)Lubricating oil filter(v) Lubricating oil pump(vi) Air Intake System :-(a) Air intake Manifold(b) Air cleaner dry type(a) Starting System :- Electric Self starter with maintenance free batteries including battery charging alternator.(b) Batteries:- 1 No. Maintenance free Battery of suitable AH capacity complete with copper conductor multistranded leads of suitable length from self starter to the battery terminals complete with initial charge and initial fill of electrolite all as specified.Make:- EXIDE / AMRON / Produced by original DG set manufacturers 75 (i) Starter gear ring(ii) Start and stop push button(iii) Ignition key / Switch(iv) Handling and operation: Salient features of accessories shall be asunder:(a) Radiator with blower fan(b) Corrosion inhibitor coolant(c) Paper element filters for fuel, lub oil and by pass.(d) Governor controlled direct fuel injection system(e) Fly wheel housing and fly wheel. 76 (D) Generator Monitoring Panel: Comprising of following:-(a) Microprocessor based integrator generator set monitories, metering,protection and control system with built torque matched volts/H3 over load control.(b) Engine protection for low lub oil pressure, high coolant temperature (alarm & shutdown)(c) Alternator protection parameters like under voltage, over current, under frequency, over frequency ( alarm & shut down)(d) Relay drivers for remote annunciations(e) Cyclic cranking(f) Auto/manual start stop(g) Alternator trim adjustment from the front key pad(h) Operates within a temperature range 0- 50°C and humidity up to 95%(J) Remote monitoring capability through separate interface modulesk) Genset metering parameters like lube oil pressure, coolant temperature, engine speed(rpm), run hours, DC voltage, 3 phase volts and 3 phase amperes, frequency, KW, KVA, power factor 77 (l) Safety Controls : - Engine low lube oil pressure, high water temperature and over speeding of engine.(m) Coupling arrangement : - Flexible coupling, fly wheel to suit flexible coupling fly wheel housing.(n) Accessories :-A VM Pads built or separately mounted to manufacturer base frames.(o) Base Frame: - Made out of ISMC 200 of sturdy design made of MS channel with necessary reinforcement and predetermined holes. (p) Fuel Tank :- Daily service fuel tank of capacity minimum 08 hrs running storage (Inbuilt) made out of 3mm thick (Heat Retardant) sheet top and bottom with calibrated level indicating arrangement, stop cock, drain plug, fuel pump of suitable capacity and connected pipe line should be installed with in built inside the acoustic enclosure is inclusive of the cost of DG Set and is as per manufacturer design.(q) Deliverables:- Confirms the norms established by CPCB. 78 (E) AMF PANEL:-(a) Auto Main Failure (AMF) panel made out of 2 mm thick CRCA sheet, powder coated of conforming to IS 8623 totally enclosed dust and vermin proof with front and rear openings of 415 Volts, 3 Phase,4 Wire, AC 50 Hz having aluminum bus bar capacity required to carry current at 100% load of 40 KVA DG set with three phase and half neutral color coded, prewired with copper flexible cable, be all as specified with the following accessories, control cable from Gen set to AMF panel: (i) 63 Amps, 4 pole contactor - 2 Nos.(ii) MCCB, 4 Pole 63 Amps, 25 KA-2 Nos for both supplies suitable fuse links.(iv) CTs 50/5A for both the supplies.(v) DC Ammeter.(vi) DC Voltmeter.(vii) Push buttons.(viii) Indication Lamps.(ix) 2 over load+ earth leakage relay. 79 (x) Multi functional digital meter for KWH,KVA,KW,Amps,volts, frequency,power factor etc.(xi) SMPS Battery charger 12V, with trickle & Boost charging(xii) On/ Off switch.(xiii) Automatic/manual switch.(xiv) Hooter.(xv) Voltage sensing relay.(xvi) Six window enunciator for fault indications.(xvii) Electro magnetic relays.(xviii) Metering required in DG set :- A, V, Hz, KVA, KW, PF & KWH Metering required in mains :- A, V, Hz. 80 (F) Acoustic enclosure: CPCB approved enclosure is free standing floor mounted factory built and modular in construction to facilitate easy assembly at work site and will be drop over housing type. It will consist of acoustically treated panel housed in sheet steel will provide easy access for maintenance, repairs and operation. The enclosure is custom built to suit conditions, with the following features:-(a) Custom built product for various equipments, with ensure the optimum performance without duration. 81 (b) Rugged in construction maintenance free and modular designs which facilitate easy at site.(c) 16 SWG (1.6 mm) thick CRCA sheets to be used for enclosure panel to ensure longer life against weathering action. High quality acoustic insulation materials to be used as per IS 8183 for maximum sound absorption. Acoustic layers are supported by perforated sheets.(d) Sheet metal components of the enclosure should undergo various stages of surface treatment prior to painting which leads to be better life of the enclosure against eathering action.(e) Special paint treatment with pure polyester 82 powder/epoxy to be provided for better weather resistance.(f) Well designed ventilation system to be provided to pump up the heat in the chamber efficiently.(g) For effective acoustic / weather sealing a special type weather sealing gaskets, new frame rubber gaskets to be used.(h) Working space is to be provided around tube equipment for easy maintenance / repairs.(j) Necessary cut out provision for entry and exist of fuel lines cable to be incorporated in the enclosure as per the requirement.(k) A see through transparent window (glass or acrylic) in front of engine panel to be provided for monitoring the operation.(l) Ducting if required, bellows, mechanical hardware like locks, hinges fasteners etc to be provided.(m) Deliverables. 75 dBA @ 1 mtr at 75% load under free field conditions. The temp inside tee enclosure will be within as per manufacturers recommendations above ambient temp. 83 (n)The enclosure should be provided with bulk head light fitting for inside illumination(o) The batteries should be placed inside the enclosure beside the DG Set on a suitable insulated platform.(p) The DG Set should be provided with external Emergency stop push button.(q) The acoustic enclosure parts shall be of powder coated after pre treatment process.(r) The powder coating shade should be Genset Green. The base frame should be painted with epoxy based black shade. 84 Make for AMF PANEL: DG SET OEMMake for ACCOUSTIC PANEL: DG SET OEMThe following provisions are deemed to be included in the rate quoted forDG set:-(a) The quoted rate shall be deemed to be inclusive of first fill of lubricant oil and final successful acceptance test.(b) DHPP for testing purpose shall be supplied by the contractor without any extra cost to department.(c) The contractor shall arrange for artificial load for testing for final testing of DG Set at site and the cost is deemed to be including in above offer. 85 (c) The quoted rate shall be deemed to be inclusive of 12 hours test run at site including of one hour on 10% overload in presence of representative detailed by accepting Officer, all arrangements are to be made by thecontractor for tests.(d) Rate quoted shall be deemed to be included in making necessary holes to walls and making good the disturbed surfaces to match to original specification and connecting up all as specified and directed . 86 (G) Civil Works :- All civil works with PCC plat form and related tofoundations including of panel and equipments and making good theexisting structure of disturbed during installation and commissioning ofGenset. The depth of the foundation shall be minimum 300 mm with ant vibration pads or as recommended by the manufacturer. 87 M & L earthing complete with galvanised steel earth plate electrode 60cmx 60cmx 6mm thick buried directly in ground earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5m below ground level, connecting to the Galvanised iron earth strip 32 x 6mm dia, by means of nuts, bolts,check nuts and washer etc. of galvanised iron and earth lead protected by provision of GI pipe medium grade 40mm bore from earth electrode to test pointincl provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4)and frame of angle iron 25 x 25 x 6mm with lugs 2 Nos and with 8mm dia MS bar handle made to shape, GI pipe medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling test point with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning in and removal of surplus soil to a distance not exceeding 50mtr, complete all as specified in electrical plate No 3 of SSR Part I and connection to earth test point including testing on completion all as directed. 88 Note :- The cost of 7.5m long galvanised iron earth strip of 32 x 6mm size and protection pipe of 40mm bore GI light grade is deemed to be included in quoted unit rate. 89 PILE FOUNDATION,PILE CAP AND GRADE BEAM 90 450mm diaBoring for Bored cast in situ piles 16 metres in soil and getting out and disposal ofspoil to a distance out side MD Land using DMC method (Direct mud circulation) through rig mechine complete all as specified and directed. 91 500mm diaBoring for Bored cast in situ piles 16 metres in soil and getting out and disposal ofspoil to a distance out side MD Land using DMC method (Direct mud circulation) through rig mechine complete all as specified and directed. 92 Add/Deduct to above item No -58 450mm bore caste in situ piles for each metrecomplete all as specified and directed. 93 Add/Deduct to above item No -59500mm bore caste in situ piles for each metre complete all as specified and directed. 94 450mm diaBoring for Bored cast in situ pilesin Chiselling / cutting through for boring for cast in situ piles through rig mechine in soft rock and getting out and disposal of spoil to a distance out side MD Landcomplete all as specified and directed. 95 500mm diaBoring for Bored cast in situ pilesin Chiselling / cutting through for boring for cast in situ piles through rig mechine in soft rock and getting out and disposal of spoil to a distance out side MD Landcomplete all as specified and directed. 96 450mm diaBoring for Bored cast in situ pilesin Chiselling / diamond cutting through for boring for cast in situ piles through rig mechine in hard rock and getting out and disposal of spoil to a distance out side MD Land complete all as specified and directed. 97 500mm diaBoring for Bored cast in situ pilesin Chiselling / diamond cutting through for boring for cast in situ piles through rig mechine in hard rock and getting out and disposal of spoil to a distance out side MD Land complete all as specified and directed. 98 S&F TMT 10 mm and over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with MS wire (annealed)not less than 0.9 mm dia conformig to Fe 500D CRS. and guide ring will be welded with main barscomplete all as specified and directed. 99 All as per item no above herein before but 6 mm dia and over upto including 10 mm dia in stirrups, spacersand binders. 100 M & L for design Mix RMC M-30 RCC inpile foundations as per derived depth complete all as specified and directed. 101 Complete Chiseling M-30 design mix concrete pile of dia 450mm of depth as required at site and removal complete all as specified and directed. 102 Chiseling M-30 design mix concrete pile of dia 500mm of depth as required at site and removal complete all as specified and directed. 103 The following Carrying out Initial Load Test on 450/500/600 mm dia. bored cast-in-situ piles as per IS-2911 (Part-IV) complete all as specified and as directed. 104 Vertical load test (compression), as per IS IS-2911 (Part-IV) for 450mm dia pile. complete all as specified and directed 105 Vertical load test (compression), as per IS IS-2911 (Part-IV) for 500mm dia pile.complete all as specified and directed 106 Lateral load test,as per IS-2911 (Part-IV) for 450mm dia pile .complete all as specified and directed 107 Lateral load test,as per IS-2911 (Part-IV) for 500mm dia pile.complete all as specified and directed 108 Carrying out Routine Load Test on 450/500/600mm dia. bored cast-in-situ piles as per IS-2911 (Part-IV) complete all as specified and as directed. 109 Vertical load test (compression), as per IS IS-2911 (Part-IV) for 450mm dia pile.complete all as specified and directed 110 Vertical load test (compression), as per IS IS-2911 (Part-IV) for 500mm dia pile.complete all as specified and directed 111 Lateral load test,as per IS-2911 (Part-IV) for 450mm dia pile.complete all as specified and directed 112 Lateral load test,as per IS-2911 (Part-IV) for 500mm dia pile.complete all as specified and directed 113 Integrate Test for all Routine piles .complete all as specified and directed 114 Excavating over areas in soft /loose soil, n exc 1.5 m deep and getting out complete all as specified and directed. 115 Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m indepth; for foundation, etc. or for shafts, wells, cesspits,manholes, pier holes, etc. n exc 10 sq m on plan and n exc1.5 m in depth and getting out in soft/loose soil complete all as specified and directed. 116 M&L for Plain Cement concrete Type B2 1:2:4 (40mm graded aggregate) as in foundations, filling and mass concrete complete all as specified and directed. 117 M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. 118 M & L for design Mix RMC M-30 RCCas inpile cap complete all as specified and directed. 119 S & F MS liner for piles of any size using MS sheet of any thickness all as directed by Engineer in charge. 120 M&L for Formwork to sides of concrete foundations, footings, Pile cap, grade beams bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter
Contract Date : 06 Mar, 2026   |   Contract Value : 10.17 Crore
BRR : 8149783 Tender For Repair/ Maintenance Of Geysers, Solar Water Heater, Summer Appliances, Dg Set, Amf Panel, Electrical Infrastructure, Periodical Servicing/ Inspection Of Various Earthing System & Certain Misc E/M Works At Aftc, 2 Dc Area, Cqae (We) & Afs East West Jalahalli; 1 Inspection, checking adjustments and minor repairs of storage water heater 25/50 ltr capacity of any type any make vertical/ horizontal type which includes the following :-(a) Inspection, taking out of drain plug & dewatering and re-fixing the same complete all as directed .(b) Checking water tightness of storage tank . (c) Checking stop cocks with outlet/inlet pipe of geysers, pressure reducing valves etc to ensure free movement of water and easy functioning of parts.(d) Inspecting over flow vent pipe connections to ensure water-tightness and proper flow.(e) Checking and correct earth continuity of electrical items.(f)Checking functioning of heating elementand correct setting adjustment of thermostat.(g) Adjustment of reducing valves, checking of dead weight type high pressure release valve and visual check of fusible plug for its intactness.(h) Replacement of defective spares shall be measured and paid under relevant items mentioned below separately as supply and fix. 2 Note : The following deemed to be inclusive in quoted rate :- 3 The above job shall be carried out by a trained electrician having ITI in electrical, documentary proof of the education of tradesman shall be produced to the Engr-in-Charge before commencement of work. 4 In case of major defects, entire job shall be completed within 15 days from the date of registration of complaint, failing which penalty charges @100/- per day shall be recovered. 5 In case of minor defects, entire job shall be completed with in 12 hrs from the time of registration of complaint, failing which penalty charges @ 50/- per job shall be recovered. 6 The entire job will be carried out in entire area of Air Force stn Jalahalli 7 All types of T&P, PVC insulation tape, minor nuts, bolts, washers etc required for maintaining the services shall be provided by contractor without any extra cost to the department. 8 Supply and fixingHeating element1.5 KW 230 volts (ISI marked) suitable for 25/50 ltrs geysers any type and any make including taking down old one including washer/ packing suitable complete all as specified and as directed. 9 Supply and fixingPVC connection for hot/ cold water made of double layer nylon braided and fabric at a pressure of 6kg/sq cm at both ends, 450 mm long, heavy duty with CP brass adopters, washers, suitable for 15 mm bore pipe including taking down existing one complete all as specified and as directed. 10 Supply and fixingin replacement pressure relieving valve CP brass confirming to relevant IS with washer suitable for 15mm bore GI pipe suitable for 25/50 ltrs geysers complete all as specified and as directed. 11 Material and labour forCutting and screwing existing steel water tubing 15/20/25 mm bore for addition /alteration required for connections to geysers etc including taking down existing one complete all as specified and directed. 12 Supply and fixingin replacement thermostat switch range of 30-80 degree celsiussuitablefor geysers of 25/50 ltrs capacity (ISI marked) complete all as specified and as directed. 13 Supply and fixingin replacement brass non return valves, screwed down, high pressure, screwed both ends for 15mm bore iron pipe or for union, ISI marked, complete all as specified and as directed. 14 Supply and fixingOuter body of MS sheet not less than 20 gauge suitable for 25 ltr geyser with white synthetic enamelled paint including taking down existing one complete all as specified and as directed. 15 Material and labour for Grouting 4 Nos of M12 X100mm bolt in stone /brick masonry wall with 1:4 CM suitable for hanging geysers complete all as specified and as directed. 16 Supply and fixing Indicator lamp for geyser 25/50 ltr capacity ofcolour green & red complete all as specified and as directed. 17 Supply and fixingHeating element2.0 KW 230 volts, ISI marked suitable for 25/50 ltrs geysers of any capacity ,any type and any make including taking down old one including washer/ packing suitable complete all as specified and as directed. 18 Supply and fixingin replacement bottom cover of MS sheet 20 gauge suitable for 25 ltrs capacity geysers and providing a coat of red oxide to inner surface and applying one coat of synthetic enamel paint by spray painting to outer surface complete all as specified and as directed. 19 Material and labourfor painting of outer surface of 50 ltrs storage type water geysers after cleaning of dust & other organic/inorganic materials if any and applying one coat of synthetic enamel white paint by spray painting and writing MES No. on the geyser complete all as specified and as directed. 20 Taking down carefully storage water heater (geyser) 25 ltr capacity of any type, any make from the location by removing the electric & water supply connection and shifted to work shop/MES store yard for repair and re-installation at any location including Supply and fixingin repair of heavy duty pin type fastener 4 long and making necessary inlet/outlet electric & water supply connection from existing source to geyser complete all as specified and as directed.Note :- Adjustment of reducing valves, checking of dead weight type high pressure release valve and visual check of fusible plug for its intactness. 21 Supply and installwater heater storage type (Geyser) vertical of capacity 25 Ltr, suitable for high pressure up to 8 barpowder coated metal body, temperature indicating dial , glass line coated tank, magnesium anode,efficient long life copper heating element, wattage 2 KW electrically operated, AC 230 Volt, BEE5 Star Rated with complete fittings/partsand accessories for fixing on wall/surfaceall as per site requirement andspecified anddirected Make:- Bajaj / Racold / Havells 22 Material and labourfor painting of outer surface of 25 ltrs storage type water geysers after cleaning of dust & other organic/inorganic materials if any and applying one coat of synthetic enamel white paint by spray painting and writing MES No on the geyser complete all as specified and as directed. 23 Taking down carefully storage water heater (geyser) 50 ltr capacity of any type, any make from the location by removing the electric & water supply connection and shifted to work shop/MES store yard for repair and re-installation at any location including Supply and fixingin repair of heavy duty pin type fastener 4 long and making necessary inlet/outlet electric & water supply connection from existing source to geyser complete all as specified and as directed.Note :- Adjustment of reducing valves, checking of dead weight type high pressure release valve and visual check of fusible plug for its intactness. 24 Dismantling carefully solar storage water heating system of 100/200/300 Ltr capacity any type for following works withtestingand refixing the same in original position making all water/ electric connection to entire satisfaction of Engineer-in-charge after repair as under :-(a) Inspection, opening, of all parts,descaling, washing of inner tankwith chemical solution and cleaning ofouter cover storage tank.(b) Checking water tightness of storage tank after cleaning.(c) Checking and correcting earth continuity of electrical items.(d) Adjustment of reducing valves, checking of dead weight type high pressure release valve and visual check of fusible plug for its intactness. (e) Replacement of damaged solar cells(f)Necessary T&P such as ladder, helper shall be contractor responsibility. 25 Note : The following deemed to be inclusive in quoted rate :- 26 The above job shall be carried out by a trained electrician having ITI in electrical, documentary proof of the education of tradesman shall be produced to the Engr-in-Charge, before commencement of work. 27 In case of major defects, entire job shall be completed within 15 days from the date of registration of complaint, failing which penalty charges @ Rs. 500/- per day shall be recovered. 28 In case of minor defects, entire job shall be completed with 12 hrs from the time of registration of complaint, failing which penalty charges @ Rs. 100/- per job shall be recovered. 29 The entire job will be carried out in entire area of Air Force stn Jalahalli 30 Necessary T&P such as ladder, helper shall be contractor responsibility. 31 All types of T&P, PVC insulation tape, minor nuts, bolts, washers etc required for maintaining the services shall be provided by contractor without any cost to the department. 32 Supply and replacement of solar tube as per existing type complete all as specified and directed. 33 Supply and fixingin replacement thermostat switch suitable for solar water heater of any make and size complete all as specified and as directed. 34 Supply only solar cells to replace the damaged cells in thesolar panel for solar water heater 200 Ltr capacitycomplete all as specified and directed. 35 Gasket setfor solar water heater panel suitable for 100Ltr capacity complete all as specified and directed. 36 Supply and fixingin replacement bib taps, cast copper alloy, with crutch or butterfly handle, chromium plated, fancy type, screwed down, screwed for 15mm bore iron pipe, ISI marked, complete all as specified and as directed. 37 Supply and Fix in replacement of solar water heater tank 100 ltr capacity tank should be 1.60 mm thickness low carbon steel with porcelain coating, outer tank should be 0.4 mm thickness stainless steel 202 grade Non Magnetic grade, insulation in PUF 50mm including provn for suitable solar tubes complete all as specified and directed.Note :- Solar tubes shall be measured and paid separately 38 Supply and replace solar panel glass suitable for 100 ltrs capacity solar water heater with gasket complete all as specified and directed. 39 Supply and fixing Stop valves, 15 mm bore of pipe fancy type, chromium plated , high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed. 40 Supply only solar cells to replace the damaged cells in thesolar panel for solar water heater 100 Ltr capacity complete all as specified and directed. 41 Supply and fix in replacementrotational moulded polyethylene water storage tank of 300 litres capacity three layered HDPE water storage tanks cylindrical vertical with closed top as per IS 12701-1996 hoisted and fixed in position, including provn of inlet pipe, over flow pipe, washout pipe etc complete all as specified and directed. 42 Material and labourforStaging / steel frame work for Solar water tanks using standard mild steel sections like angle iron / MS pipe / flat iron / sheets etc using steel of Fe 410-W (Gde E-250) quality - A including necessary welding suitable to keep 300 ltrs PVC water tank in repairs complete all as specified and directed. 43 M&L for Preparing new steel surfaces of any description over 10cm in width or girth , not otherwise described and applying two coats of Synthetic enamel Paint over a coat of red oxideprimer complete all as specified and directed. 44 Supply and fixing 15mm bore galvanized steel water tubing, medium grade with all fittings and fixed complete to walls and ceiling or laid in floors including taking up or down old steel tubing and connection complete all as specified and directed.. 45 Supply and fixingin repair 20 mm dia Chlorinated PVC (CPVC) Pipes of pressure rating 10kgf/cm2including fittings like socket / union / Tee / Reducer / Nipple etc complete fixed to wall/ceilings/ in floors etc, complete all as specified and directed. 46 Supply and fixingin repair Chlorinated PVC (CPVC) Gate Valve of size 20 mm dia, (ISI marked) complete all as specified and as directed. 47 Supply and fixingin repair 25 mm dia Chlorinated PVC (CPVC) Pipes of pressure rating 10kgf/cm2including fittings like socket / union / Tee / Reducer / Nipple etc complete fixed to wall/ceilings/ in floors etc, complete all as specified and directed. 48 Supply and fixingin repair Chlorinated PVC (CPVC) Gate Valve of size 25 mm dia,( ISI marked) complete all as specified and as directed. 49 Supply and fixingin repair 32 mm dia Chlorinated PVC (CPVC) Pipes of pressure rating 10kgf/cm2including fittings like socket / union / Tee / Reducer / Nipple etc complete fixed to wall/ceilings/ in floors etc, complete all as specified and directed. 50 Supply and fixingin repair Chlorinated PVC (CPVC) Gate Valve of size 32 mm dia,( ISI marked) complete all as specified and as directed. 51 Supply and fixingin repair 40 mm dia Chlorinated PVC (CPVC) Pipes of pressure rating 10kgf/cm2including fittings like socket / union / Tee / Reducer / Nipple etc complete fixed to wall/ceilings/ in floors etc, complete all as specified and directed. 52 Supply and fixingin repair Chlorinated PVC (CPVC) Gate Valve of size 40 mm dia,( ISI marked) complete all as specified and as directed. 53 S&F in repair PVC insulated and FRLS PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, 2.5 Sqmm 3 core,complete all as spcified and directed. Make : Havells/ Polycab/ Plaza 54 Taking down ofexhaust fan any size/capacity after disconnecting cable connection, and refixing same in original position after necessary repair/over hauling including replacement of parts of minor nature such as screws, lugs, insulation tape, nuts, bolts, washers etc after cleaning the metal surface, greasing/lubricant etc to make it functional andmaking connection by replacing PVC insulated unsheathed cable of copper conductor of size 1.5 Sqmm from ceiling rose/ connector fan (minimum 0.50 Mtr length) aredeemed to be inclusive in quoted rate all as specified and as directed. Note:- (a)Rewinding, and materials to be replaced are measured separately.) 55 (b)The above job shall be carried out by a trained electrician having qualified in ITI ( electrician Trade), documentary proof of the education of tradesman shall be produced to Engr-in-Charge before commencement of work. 56 (c)Defective unserviceable part like fan bush,bearing etc. will be paid under respective item here-in-after as supply only through proper documentation. 57 (d)The entire job will be carried out inAir Force stn Jalahalli 58 (e) Necessary T&P such as ladder, helper shall be contractor responsibility. 59 (f)All types of T&P, PVC insulation tape, minor nuts, bolts, washers etc required for maintaining the services shall be provided by contractor without any extra cost to the department. 60 (g)Any fan found defective/not working shall be brought to AGE E/M store yard & re-fixed after repairing. 61 (j)In case of major defects, entire job shall be completed within 10 days from the date of registration of complaint, failing which penalty charges @100/- per day shall be recovered. 62 (k) In case of minor defects, entire job shall be completed with 12 hrs from the time of registration of complaint, failing which penalty charges @ 50/- per job shall be recovered. 63 Supply only 3.15 mfd capacity exhaust fan condenser complete all as specified and directed. 64 Supply only fan bush of suitable size for exhaust fan of the any sweep complete all as specified and directed. 65 Supply only fan bearing of suitable size for exhaust fan of 250mmsweepincluding greasing complete all as specified and directed. 66 Supply only metal louvers of suitable size for exhaust fan of the 250mmsweep complete all as specified and directed. 67 Supply only 2.5 mfd capacity ceiling /exhaust fan condensers complete all as specified and directed. 68 Supply only fan bearing of suitable size for exhaust fan of 300mmsweepincluding greasing complete all as specified and directed. 69 Supply only metal louvers of suitable size for exhaust fan of the 300 mmsweep complete all as specified and directed. 70 Supply only 4 mfd capacity ceiling /exhaust fan condensers complete all as specified and directed complete all as specified and directed. 71 Supply only fan bearing of suitable size for exhaust fan of 450mmsweepincluding greasing complete all as specified and directed. 72 Supply only metal louvers of suitable size for exhaust fan of the 450 mmsweep complete all as specified and directed. 73 M&L for cutting of hole through stone wall with the help of Core cutting machineincluding providing, fixing and removing shoring,cleaning,internal plastering and removing surplus hard core,rubbish not exceeding 50 mtrs including fixing of exhaust fan of size 250-450 mm all as specified and as directed. 74 Supply and fixingExhaust fan250 mm sweep 230/ 240 volt AC single phase PVC body1400 RPM including necessary nut, bolts / screws including taking down existing one writing MES No with synthetic enamel paint all specified and directed. Make-Havells /bajaj/ Crompton Greaves.Note:-Old Unserviceable Exhaust fan shall be deposited to MES store yard. 75 Material and labour for winding of Exhaust fan 250mm sweep of any make with super enamelled copper winding wire of existing gauge (wt of copper winding wire per fan 250 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size not less than0.75 mm of length not more than one meter with each fan complete all as specified and directed. Note :- (i)Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit schedule. 76 M&L in repairfor stainless steel wire cloth 0.63 mm dia of wire and average width of aperture 1:40 mm for covering of exhaust fan hole in wall of size 450 mm X450 mm with PVC/woodenbeading fixed on wall including necessary fixing arrangement up to hight 11 mtrcomplete all as specified and directed.Note : All safety measures is the responsible of the contractor 77 Supply and fixingExhaust fan 300 mm sweep 230/ 240 volt AC single phase PVC body 1400 RPM including necessary nut, bolts / screws including taking down existing one writing MES No with synthetic enamel paint all specified and directed. Make-Havells /bajaj/ Crompton Greaves.Note:-Old Unserviceable Exhaust fan shall be deposited to MES store yard. 78 Material and labour for winding of Exhaust fan 300mm sweep of any make with super enamelled copper winding wire of existing gauge (wt of copper winding wire per fan 250 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size not less than0.75 mm of length not more than one meter with each fan complete all as specified and directed. Note :- (i)Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit schedule. 79 M&L for cutting of hole through brick wall with the help of Core cutting machineincluding providing, fixing and removing shoring,cleaning,internal plastering and removing surplus hard core,rubbish not exceeding 50 mtrs including fixing of exhaust fan of size 250-450 mm all as specified and as directed. 80 Supply and fixingExhaust Fan 300 mm sweep, 230/240 volt AC single phase, heavy duty,1400 RPM, corrosion less mild steel body of motor, suitable hold fast with necessary nut, bolts / screws with louver including taking down existing one,writing MES No. with synthetic enamel paint all specified and directed. Make- Havells /Bajaj/ Almonard.Note:-Old Unserviceable domestic exhaust fan shall be deposited to MES store yard. 81 M&L for repair louver made of galvanised steel suitable for 300 mm size exhaust fan, fixed on wall including necessary fixing arrengement up to height 11 mtrcomplete all as specified and directed.Note : All safety measures shall be the responsible of the contractor. 82 Supply and fixingExhaust Fan 450 mm sweep, 230/240 volt AC single phase, heavy duty,1400 RPM, corrosion less mild steel body of motor, suitable hold fast with necessary nut, bolts / screws with louver including taking down existing one,writing MES No. with synthetic enamel paint all specified and directed. Make- Havells /Bajaj/ Almonard.Note:-Old Unserviceable domestic exhaust fan shall be deposited to MES store yard. 83 Material and labour for winding of Exhaust fan 450mm sweep of any make with super enamelled copper winding wire of existing gauge (wt of copper winding wire per fan 250 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size 0.0076mm of length not more than one meter with each fan complete all as specified and directed. Note :- (i)Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit schedule. 84 Taking down ofwall mounted/Pedastal fanof size 400/450mm after disconnecting cable connection, and refixing same in original position after necessary repair/over hauling .(Note:- Repair, rewinding, over hauling and materials to be replaced are measured separately.) 85 Supply only fan bush of suitable size for wall mounted/Pedastalfan of the any sweep complete all as specified and directed. 86 Supply only fan bearing of suitable size for wall mounted/Pedastal fan of 400 mmsweep complete all as specified and directed. 87 Material and labour for winding of wall mounted fan400mm sweep of any make with super enamelled copper winding wire of existing gauge (wt of copper winding wire per fan 350 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of sizenot less than0.75 mm of length not more than one meter with each fan complete all as specified and directed. Note :- (i) Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit schedule. 88 Material and labour for winding of wall mounted/Pedastal fan450mm sweep of any make with super enamelled copper winding wire of existing gauge (wt of copper winding wire per fan 350 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size not less than0.75 mm of length not more than one meter with each fan complete all as specified and directed. Note :- (i) Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit schedule. 89 Removing the window/ split type AC of 1.5/ 2 ton capacity of any make from any location for carrying out servicing complete as and when directed and installing back at original location, testing and commissioning complete all as specified and directed.Note :- The rate of following deemed to be included in quoted rate :-a) Cleaning the body, evaporator and condenser with detergent, combing the pins and flushing with air blowerb) Checking electrical connection, cleaning, Greasing, oiling, fan/blower motor, cleaning of air filter with blowerc) Wrapping suction and discharge pipe with foam insulation and white roll ,changing drainage pipe when necessary d)The unit rate quoted by the tenderer inclusive for Removing, servicing,installation, commissioning and testing of all equipment’s,tools and plants, and back in on final position complete (e) The work shall be done by a specialized team of Engineer/Technicians of OEM.(f) Spares will be measured and paid separately.(g) Refrigerant gas will be measured & paid separately. 90 Supply and fixing Blower of indoor unit suitable for 1.5 Ton / 2 Ton splitAC including taking down existing unserviceable one at any location complete all as specified and directed. 91 Supply and fixing Filter (in replacement) suitable for split type Air Conditioner of any make upto 2 TR capacity, including taking down existing one complete all as specified and directed. 92 Supply and fix Over load relay (in replacement) suitable for split type Air Conditioner of any make up to 2.0 TR capacity, including taking down existing one complete all as specified and directed. 93 Supply and fixingHermetic sealed/Rotory new compressor for 1.5 TR split type AC capacity including disconnecting the electrical and refrigerant connection of defective sealed unit ofsplit type ACof capacity 1.5 Ton and connection of all pipe line & charging of refrigerant and testing complete including taking down existing one complete all as specified and directed. 94 Supply and fix polyurethane foam insulation indoor to outdoor unit suitable for 1.5 Ton to 2 Ton split type A/C of any type and at any locationincluding taking down existing one complete all as specified and directed. 95 Supply and fix discharge valve suitable for 1.5 Ton/2 Ton of split type AC including taking down existing one complete all as specified and directed. 96 Supply and fixing Condenser Fan motor (in replacement) suitable for window type Air Conditioner of any make up to and including 1.5/2.0 TR capacity,including taking down existing one and complete all as specified and directed. 97 Supply and fix Suction valve suitable for 1.5 Ton/2 Ton of split type AC of existing make complete all as specified and directed. 98 Supply and fixing Blower motor (in replacement) suitable for split type Air Conditioner of any make up to 2 TR capacity including taking down existing unserviceable one, complete all as specified and directed. 99 Supply and fixing as in repair offlexible PVC pipe of suitable size for indoor unit drain water of split AC suitable for any type and any capacity complete all as specified and directed. 100 Supply and fixas in repair dummy nut of dia 3/8 suitable for 1.5 Ton/2 Ton of split type AC complete all as specified and directed. 101 Supply and fix dummynut of dia 1/4 suitable for 1.5 Ton/2 Ton of split type AC complete all as specified and directed. 102 Supply and fix as in repair dummy nut of dia 5/8 suitable for 1.5 Ton/2 Ton of split type AC complete all as specified and directed. 103 Supply and fix as in repair dummy nut of dia 1/2 suitable for 1.5 Ton/2 Ton of split type AC complete all as specified and directed. 104 Supply and fixing Remote assembly corded/cordless (in replacement) for any type and size of split type ACs, upto 2.0 TRincluding taking down existing one complete all as specified and directed. 105 Supply and fixingCondenser coil (in replacement) after disconnecting the refrigerant connection of defective condenser coil unit of split type ACupto 2.0 TRand replacing the condenser coil unit connectingthe same unit withrefrigerant connections complete including taking down existing one complete all as specified and directed. 106 Supply and fixing Front grill (in replacement) suitable for split type Air Conditioner of any make up to 2 TR capacity, including taking down existing one all as specified and directed. 107 Supply and fix MS wall bracketsuitable for fixing of out door unit of split type Air Conditioner with necessary nuts, bolts & washers and removing old unserviceable items and making good disturbed surfaces to match with the existing complete all as specified and directed. 108 Supply and fixingHermetic sealed/Rotory new compressor for 2 TR split type AC capacity including disconnecting the electrical and refrigerant connection of defective sealed unit ofsplit type ACof capacity 2 Ton and connection of all pipe line & charging of refrigerant and testing complete including taking down existing one complete all as specified and directed. 109 Supply and fix Condenser coil (in replacement) after disconnecting the refrigerant connection of defective condenser coil unit of split type ACupto 1.5 TRand replacing the condenser coil unit connectingthe same unit withrefrigerant connections complete including taking down existing one all as specified and directed. 110 Supply and fix as in repair PVCinsulated multi stranded copper conductor 3 core 2.5 sq.mm, including connecting up and taking down existing unserviceable cable of any description and size complete all as specified and directed. 111 Supply and fixing Remote sensing unit (in replacement) for upto 2.0 TR split type AC including taking down existing unserviceable one complete all as specified and directed. 112 Supply and fixindoor unit including blower fan , PCB board and all accessories capacity 1.5/2.0 Ton split type A/C including taking down existing unserviceable one any type complete all as specified and directed. 113 Material and labourfor shifting of Air Conditioner, Split type capacity up to 2 TR from existing location to new location as per user requirement and installing, toping up of gas, replacement of copper tubing connecting up, commissioning and testing complete all as specified and as directed.Note :- The rate for following works deemed to be included in quoted rate :-(a)Transportation of air conditioner any type any capacity from one to other location. (b) Fixing only base plate with necessary fixing material on stone / brick walls and as directed (c) Fixing only outdoor and indoor units as required and directed (d) Connecting indoor / outdoors units of split ACs with copper tubes, flairs nuts, warping suction and discharge lines with inclucating materials with necessary fixing arrangements such as bolts, nuts washers and clamps etc. on walls (e) fixing PVC pipes 50mm dia for outlet of outdoor units to drain out dew water with necessary clamps. (f) Fixing of wall mounting voltage stabilizer of 3 KVA to 5 KVA capacity on the wall with necessary fixing arrangements such as bolts, nuts washers and clamps etc on wall. (g) Fixing PVC hose/ PVC pipes of 15mm sizes as reqd at site with necessary junction boxes, PVC bends etc. including two length of PVC copper cables of 4 sqmm size for electrical connection of ACs. (h) No additional payment shall be made for leakage of gas occurring during shifting of Air Conditioner and topping up of required gas.(j)Fixing of copper tubing of qty of required size. 114 Supply and fixing as in repair ofCopper tubing of size 1/2 flare size conforming to relevant IScomplete all as specified and directed. 115 Supply and fixing as in repair ofCopper tubing of size 1/4 flare size conforming to relevant IS complete all as specified and directed. 116 Supply and fixing as in repairof Copper tubing of size 5/8 flare size conforming to relevant IS complete all as specified and directed. 117 Supply and fixing as in repair of Copper tubing of size 3/8 flare size conforming to relevant IScomplete all as specified and directed. 118 Supply and fix PCB board of any make for indoor unit of split AC 1.5 Ton/ 2 Tonincluding taking down existing one complete all as specified and directed. 119 Removing old unserviceablesplit type air conditioner outdoor unit frameand Supply and fixoutdoor unit frame ofthesplit type air conditioner 1.5/2 TR capacity, complete with refixing with all accessories such as hermetically sealedcompressor andcondenser unit, capacitors, relays, fan motor, duly prewired and including connecting of existing refrigerant gas piping, electrical connections and testing etccomplete all as specified and directed. 120 Supply and fix 3 pin metal clad plug top 20 Amps, AC 230 volts for any type of AC including taking down existing unserviceable one complete all as specified and as directed. 121 Supply and fix single phase single pole contactor suitable for 1.5/ 2.0 split type AC complete all as specified and as directed. 122 Supply & fix metal clad switch socket single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20A concealed in walls complete all as specified and as directed.Make : Havells/ Indo asian/ Legrand 123 Supply and fix flair nut of dia 5/8 suitable for 1.5 Ton/2 Ton of split type AC complete all as specified and as directed. 124 Supply and fix flair nut of dia 1/2 suitable for 1.5 Ton/2 Ton of split type AC complete all as specified and as directed. 125 Supply and fix flair nut of dia 3/8 suitable for 1.5 Ton/2 Ton of split type AC complete all as specified and as directed. 126 Supply and fix flair nut of dia 1/4 suitable for 1.5 Ton/2 Ton of split type AC complete all as specified and as directed. 127 Supply and fix flair nut of dia 1/16 suitable for 1.5 Ton/2 Ton of split type AC complete all as specified and as directed. 128 M&L core cutting ofof size 50 mm dia in stonewall with the help of machineand preparing surface to make goodmatching with existing surface coloured complete all as specified and directed. 129 Supply and fix overload protector forsplit AC 1.5/2 Ton TR capacity including taking down existing unserviceable one complete all as specified anddirected. 130 M&L core cutting ofof size 50 mm dia in bricks wall with the help of machineand preparing surface to make goodmatching with existing surface coloured complete all as specified and directed. 131 Material and labour for pressure testing and rectifying the leakages found in the system of window/ split type ACs up to 2 Ton capacity including vacumizing, charging and checking the gas pressure to desire level complete for satisfactory functioning complete all as specified and directed.Note: Toping up of gas shall be measured and paid separately 132 Repair and maintenance of inverter type splitAC of any capacity / any Make from any location including attending breakdown calls, routine maintenance and servicing ,testing and commissioning all as specified and directed here under :-a) Cleaning the body, evaporator and condenser with detergent, combing the pins and flushing with air blower.b) Checking electrical connection, cleaning, Greasing, oiling, fan motor, cleaning of air filter with blower.(c) Testing all copper tube ,joints, leads for any leaking and Top up with the refrigerant gas if necessary.(d)The work shall be done by a specialized team of Engineer/Technicians of OEM. 133 Supply and fix DC blower fan motor for inverter split AC of 1.5 Ton to 2 Ton capacity and including taking down existing unserviceable one of any capacity and at any location complete all as specified and directed. 134 Supply and fixingPCB board of inverter type split type ACfor 1.5 Ton/2 Ton capacity including taking down existing unserviceable one at any location complete all as specified and directed. 135 Taking out, inspection, checking adjustment and minor repair of unserviceable refrigerator 165/175/180/185/190/260/277/286/290/308/310/315/350/360/375 ltr capacity of any type any make for repair/ replacement of defective parts such as condenser, PVC pipe, loose electrical connection etc., cleaning, condenser unit of foreign particle and descaling with carbon di oxide gas to ensure smooth flow of refrigerating gas, reassembling the appliance, testing and placing in original position complete all as specified and as directed .Note :- Repair/ replacement of unserviceable parts shall be measured and paid separately complete all as specified and as directed . 136 Supply and fixingEvaporator coil, suitable for refrigerator of 260 to 308 ltrs any make size and type (in replacement)complete all as specified and as directed. 137 Supply and fixingChiller tray (in replacement) suitable for Refrigerator of any make, 260 to 308 litres capacity,complete all as specified anddirected. 138 Material and labour for Freezer compartment including door and accessories suitable for refrigerator 260, 286,308, 315 and 350 ltrs capacity refrigerator and including taking existing unserviceable one complete all as specified and as directed. 139 Supply and fixinghermetically sealed new compressor (in replacement) for 260 to 308 Ltrcapacity of refrigeratorincluding filling of refrigerant suitable and testing complete by disconnecting the electrical and refrigerant connection of defective sealed unit of Refrigerator compressor of capacity 260 to 308 litres complete all as specified and directed. 140 Supply and fixingVegetable tray (in replacement) suitable for Refrigerator of any make, 260 to 308 litres capacity,complete all as specified and as directed. 141 Supply and fixingin replacement condensing coil for refrigerator of capacity 260 to 308 Ltr complete all as specified and directed. 142 Material and labourfor pressure testing and rectifying the leakage found in the system of refrigerator of capacity 260 to 308 litres including vacuuming and charging the refrigerant gas to the desired pressure and filling new compressor oil etc. complete for satisfactory functioning complete all as specified and as directed.Note:Topping up of gas shall be measured and paid separately 143 Supply and fixingPVC shelf transparent type of tough plastic suitable for refrigerator of capacity 260 to 308 ltrs complete including taking down existing unserviceable one complete all as specified and directed. 144 Supply and fixing superior quality plastic/PVC Ice cube tray for refrigerator of capacity 260 Ltrs to 308 ltrs complete all as specified and directed. 145 Supply and fix in repair electric bulb 20 watt 230v threaded type for refrigerator of Capacity 260 ltrs to 308 ltrs complete all as specified and directed. 146 Material and labourfor pressure testing and rectifying the leakage found in the system of refrigerator of capacity 165 to 260 litres including vacuuming and charging the refrigerantgas to the desired pressure and filling new compressor oil etc. complete for satisfactory functioning complete all as specified and directed.Note:Topping up of gas shall be measured and paid separately 147 Supply and fix in repair magnetic beading for refrigerator of cap 165 ltrs to 335 ltrs complete all as specified and directed. 148 Supply and fixingEvaporator coil, suitable for refrigerator of 165 to 260 ltrs any make size and type (in replacement) complete all as specified and directed. 149 Material and labour for preparing the old painted surface of refrigeratorof capacity 165 litres to 350 litres and spray painting with synthetic enamel paint of approved colour complete all as specified and directed. 150 Supply and fixinghermetically sealed new compressor (in replacement) for 165to 260 Ltrcapacity of refrigeratorincluding filling of refrigerant suitable and testing complete by disconnecting the electrical and refrigerant connection of defective sealed unit of Refrigerator compressor of capacity 165 to 260 litres complete all as specified and directed. 151 Supply and fixingRelay, box type, suitable for refrigerator of any make 165 to 335 litres capacity (in replacement) fixed in repairs, complete all as specified and directed. 152 Supply and fixingChiller tray (in replacement) suitable for Refrigerator of any make, 165 to 260 litres capacity,all as specified and directed. 153 Supply and fixing Freezer compartment including door and accessories suitable for refrigerator 165/175 ltrs capacity refrigerator and including taking down existing one complete all as specified anddirected. 154 Supply and fixingin replacement condensing coil for refrigerator of capacity 165 to 260 Ltr complete all as specified and directed. 155 Supply and fixingin replacement Gasket, suitable for door of Refrigerator of any make, 165 to 350 litres capacity, fixed in repairs all as specified and directed. 156 Supply and fixingMulti capacitors 2 µfd for cooling appliances including taking down existing unserviceable one complete all as specified and as directed. 157 Supply and fixingVegetable tray (in replacement) suitable for Refrigerator of any make, 165 to 260 litres capacity,complete all as specified and directed. 158 Supply and fixingTimer and sensor of Refrigerator including taking down existing unserviceable one complete all as specified and as directed . 159 Supply and fixingCopper capillary tubesuitable forrefrigeratorincluding taking down existing unserviceable one, any description complete all as specified and directed. 160 Supply and fixingFilter of refrigerator including taking down existing unserviceable one complete all as specified and as directed. 161 Supply and fixingThermostat, suitable for refrigerator of any make 165 to 350 litres capacity (in replacement) all as specified and directed. 162 Supply and fixingin replacement condensing coil for refrigerator of capacity 308 to 350 Ltr complete all as specified and directed. 163 Supply and fixinghermetically sealed new compressor (in replacement) for 308 to 350 Ltrcapacity of refrigeratorincluding filling of refrigerant suitable and testing complete by disconnecting the electrical and refrigerant connection of defective sealed unit of Refrigerator compressor of capacity 308 to 350 litres complete all as specified and as directed. 164 Supply and fixingEvaporator coil, suitable for refrigerator of 308 to 350 ltrs any make size and type (in replacement)complete all as specified anddirected. 165 Servicing theVoltage Stabilizer 0.5 KVA to 2 KVA single phaseafter replacing transformer, PCB,u/s electronic parts, setting/testing of buck/boost relay, assembleback & fixing in its original position including testing for proper functioningcomplete all as specified and as directed. 166 Supply and fixingOver load protector for refrigerator including taking down existing unserviceable one any description complete all as specified and as directed.. 167 Supply and fixingStarting relay suitable for refrigerator including taking down existing unserviceable one complete all as specified and as directed 168 Supply and fixingMulti capacitors 2.5 µfd for cooling appliances including taking down existing unserviceable one complete all as specified and as directed. 169 Material and labourfor pressure testing and rectifying the leakage found in the system of refrigerator of capacity 308 to 350 litres including vacuuming and charging the refrigerantgas to the desired pressure and filling new compressor oil etc. complete for satisfactory functioning complete all as specified and directed.Note: Topping up of gas shall be measured and paid separately 170 Servicing theVoltage Stabilizer 4 KVA to 5 KVA single phaseafter replacing transformer, PCB,u/s electronic parts, setting/testing of buck/boost relay, assembleback & fixing in its original position including testing for proper functioningcomplete all as specified and as directed. 171 Supply and fixingMulti capacitors 4 µfd for cooling appliances including taking down existing unserviceable one all as specified and as directed. 172 Taking out, inspection, checking adjustment and minor repair of unserviceable water cooler 40/80/60/120/150/180 ltr capacity of any type any make for repair/ replacement of defective parts such as condenser, PVC pipe, loose water tap, float valve, loose electrical connection etc., cleaning condenser unit of foreign particle and descaling with carbon di oxide gas to ensure smooth flow of water cooler gas, reassembling the appliance, testing and placing in original position complete all as specified and as directed .Note :- Repair/ replacement of unserviceable parts shall be measured and paid separately complete all as specified and as directed . 173 Supply and fixingElectric condenser Fan motor, AC 230 volt, single phase with recommended RPM etc. (in replacement) suitable for water coolerof any make of 150/180 litres capacity, complete all as specified and directed. 174 Taking down corroded bottom portion of water cooler of 150 litres capacity and provision of 14 gauge MS sheet with suitable size angle iron frame work duly welded to the body of the water coolerincluding two coats of synthetic enamel painting over a coat of red oxide primer to match the existing colour all as specified and directed. 175 Supply and fix Stainless steel tray (in replacement) suitable for water cooler of160 to 180 Litres capacity complete all as specified and directed. 176 Supply and fixingDoor gasket (in replacement) suitable for lid of water cooler up to 150 litres capacity, complete all as specified and directed. 177 Supply and fixinghermetic sealed new compressor (in replacement) for water cooler 150 litre/Hr cooling capacityincluding disconnecting the electrical and refrigerant connection of defective sealed unit of storage type water cooler of capacity 150 litres and connection of all pipe line & charging of refrigerant and testing complete including taking down existing one all as specified and directed. 178 Supply and fixingPVC drain out pipe 32 mm dia bore (in replacement) as per existing including providing necessary GI clamps, nut bolt etc.all as specified and directed 179 Supply and fixingSelf closing push type Bib tap 15mm diamade out of cast copper alloy chromium plated (in replacement) suitable for water cooler conforming to ISI mark, including testing and leak proof etc. complete all as specified and directed. 180 Supply and fixingball brass valve high pressure 15mm dia complete fitting such as PVC polythene ball, layer check nut washer etc for water cooler of any capacity including taking down existing one all directed. 181 Supply and fix in replacement of gun metal gate valve 15mm dia including GI nipple including taking down existing one all as specified and as directed 182 Material and labourfor preparing the old painted surface of the water coolers of capacity cap 150 Litres and spray painting with synthetic enamel paint over one coat of red oxide primer including replacement of worn out nut, bolt, washer, screw and writing MES No and capacity all as specified and directed. 183 Material and labourfor pressure testing and rectifying the leakages found in the system of water cooler of capacity 150 litres and vacuuming and charging refrigerant gas and filling new compressor oil etc. complete for satisfactory functioning all as specified and directed.Note:Topping up of gas shall be measured and paid separately 184 Supply and fixingElectric condenser Fan motor, AC 230 volt, single phase with recommended RPM etc. (in replacement) suitable for water coolerof any make of 60/120 litres capacity, including taking down existing one all as specified and directed. 185 Supply and fixinghermetic sealed new compressor (in replacement) for water cooler 60/120 ltr/Hr cooling capacityincluding disconnecting the electrical and refrigerant connection of defective sealed unit of storage type water cooler of capacity 60/120 litres and connection of all pipe line & charging of refrigerant and testing complete all as specified and directed. 186 Material and labourfor pressure testing and rectifying the leakages found in the system of water cooler of capacity 60/120 litres and vacuuming and charging refrigerant gasand filling new compressor oil etc. complete for satisfactory functioning all as specified and directed.Note: Topping up of gas shall be measured and paid separately 187 Taking down corroded bottom portion of water cooler of 40/80 litres capacity and provision of 14 gauge MS sheet with suitable size angle iron frame work duly welded to the body of the water coolerincluding two coats of synthetic enamel painting over a coat of red oxide primer to match the existing colour all as specified and directed. 188 Supply and fixingElectric condenser Fan motor, AC 230 volt, single phase with recommended RPM etc (in replacement) suitable for water coolerof any make of 40/80 litres capacity, complete all as specified and as directed. 189 Supply and fix Stainless steel tray (in replacement) suitable for water cooler of 40/ 80 litres capacity all as specified and directed. 190 Supply and fixingCondensing coil suitable for water cooler of capacity 40/80 ltr/hr cooling capacity (in replacement) complete all as specified and as directed. 191 Supply and fixingEvaporator coil suitable for water cooler of capacity 40/80 ltr/hr cooling capacity (in replacement) complete all as specified directed. 192 Supply and fixinghermetic sealed new compressor (in replacement) for water cooler 40/80 ltr/Hr cooling capacityincluding disconnecting the electrical and refrigerant connection of defective sealed unit of storage type water cooler of capacity 40/80 litres and connection of all pipe line & charging of refrigerant and testing complete all as specified and directed. 193 Material and labourfor preparing the old painted surface of the water coolers of capacity of 40/80 Litres and spray painting with synthetic enamel paint over one coat of red oxide primer including replacement of worn out nut, bolt, washer, screw and writing MES No and capacity complete all as specified and as directed. 194 Material and labourfor pressure testing and rectifying the leakages found in the system of water cooler of capacity 40/ 80 litres and vacuuming and charging refrigerant gasand filling new compressor oil etc. complete for satisfactory functioning all as specified and directed.Note: Topping up of gas shall be measured and paid separately 195 Supply and fixingCarbon (filter) 12” size incl taking down old unsv complete all as specified and as directed. 196 Supply and fix in replacement of filter for water cooler of any size any make complete all as specified and as directed. 197 Supply and fixingMulti capacitors 4.5 µfd for cooling appliances including taking down existing unserviceable one complete all as specified and as directed. 198 Supply and charging of refrigerant gas R-134a to water cooler,refrigerator and deep freezer air conditioner of any type, make and capacity all as specified and directed.(i) Empty cylinder shall be returned to contractor.(ii) Payment shall be made for net weight of gas filled. 199 Material and labourfor repairing the leakage in the steel water tank of water cooler of any capacity by welding brazing/ soldering complete all as specified and directed. 200 Supply and fixingMulti capacitors 6 µfd for cooling appliances including taking down existing unserviceable one complete all as specified and as directed. 201 Material and labourfor taking down of ceiling fan of size 1200/1400mmsweep for safety checking by replacingdefective parts/painting/rewinding and re-fixing the ceiling fan after repairs, all as specified and as directed by Engr-in-charge. (Note:- The replacement of unserviceable items like capacitor, Bearings, Bush, Canopy, down rod etc. shall be made as directed which will be measured and paid separately under respective items as Supply only. However,parts of minor nature such as screws, lugs, insulation tape, nuts, bolts, washers etc after cleaning the metal surface, greasing/lubricant etc to make it functional andmaking connection by replacing PVC insulated unsheathed cable of copper conductor of size 1.5 Sqmm from ceiling rose/ connector fan (minimum 0.50 Mtr length) including cost of labour for above replacement aredeemed to be inclusive in quoted rate all as directed. 202 Note:- The following items shall be deemed to be inclusive in the unit rate quoted against Sl Item No 201(a) In each job, checking the functioning of fan including its connections, cleaning of fan, greasing of fan and mechanical check i.e. tightening of loose screw, nuts, bolts, etc are inclusive in unit quoted rate. 203 (b)The above job shall be carried out by a trained electrician having qualified in ITI ( electrician Trade), documentary proof of the education of tradesman shall be produced to the Engr-in- Charge, before commencement of work. 204 (c)Replacement of unserviceable parts like rubber bush, clamps, bolts, nuts, washers, safety pin, bearing etc shall be paid under respective item here-in-after as supply only through proper documentation. 205 (d)The entire job shall be carried out inAir Force stn Jalahalli 206 (e)Necessary T&P such as ladder, required manpower for taking down and refixing after repair shall be of contractors responsibility. 207 (f)All types of T&P, PVC insulation tape, minor nuts, bolts, washers etc required for maintaining the services shall be provided by contractor without any extra cost to the department. 208 (g)Any fan found defective/not working shall be brought to AGE E/M store yard & re-fixed after repairing. 209 (j)In case of major defects, entire job shall be completed within 10 days from the date of registration of complaint, failing which penalty charges @100/- per day shall be recovered. 210 (k) In case of minor defects, entire job shall be completed within12 hrs from the time of registration of complaint, failing which penalty charges @ 50/- per job shall be recovered. 211 Supply onlyfan bearing suitable forceiling fan 1200mm /1400 mm sweep (bearing with 8 balls shall be used ) Make:- NBC/TATA/SKF 212 Supply only rotor of ceiling fan of any size complete all as specified and directed. 213 Supply onlygun metalbush of suitable size for ceiling fan 1200mm /1400 mm sweep complete all as specified and directed. 214 Supply only fan canopies for ceiling fan size of 1200mm/1400mm sweep complete all as specified and directed. 215 Supply onlydown rod for ceiling fan with 15mm dia (of length not less than 45cm and not more than 60cm) with hanging clamps for ceiling fan complete all as specified and directed. 216 Supply only Rubber reel bushes for ceiling fan of size 1200/1400mm sweep complete all as specified and directed. 217 Supply only steel screw (for fixing of fan blade) as per site requirement for any make of ceiling fan complete all as specified and directed. 218 Supply onlyouter body of ceiling fan of any size complete all as specified and directed. 219 Supply onlydown rod for ceiling fan with 15mm dia (of length not less than 180cm and not more than 210cm) with hanging clamps for ceiling fan complete all as specified and directed. 220 Supply only U clamp for hanging ceiling fan with all nuts, bolts and washers complete all as specified and directed. 221 Supply onlydown rod for ceiling fan with 15mm dia (of length not less than 90cm and not more than 120cm) with hanging clamps for ceiling fan complete all as specified and directed. 222 Supply onlyblades (made of aluminium) suitable for 1200mm sweep ceiling fan of any make with set of screws complete all as specifiedand directed . 223 Supply only safety cotter pins 40mm to 50mm longwith nuts and bolt with washers for ceiling fan of size 1200/1400mm sweep complete all as specified and directed. 224 Supply onlyblades (made of aluminium) suitable for 1400mm sweep ceiling fan of any make with set of screws complete all as specifiedand directed. 225 Supply and fixing in replacement of unserviceableceiling fan 1200mm sweep, energy efficient BLDCISI mark withstar rating 230 Volts AC 50 Hz, single phase including provision of fixing arrangement, nut and bolt andflexible copper cable 3 core of size 1.5 sqmm not less than 0.5 m long complete including taking down existing one, writing MES No with synthetic enamel paint all as specified and as directed. Make : Havells/Bajaj/ Orient.Note:-(a)Old Unserviceable ceiling fan shall be deposited to MES store yard. 226 Material and labour for winding of ceiling fan motor 1200 mm sweep of any make with super enamelled copper winding wire of existing gauge (wt of copper winding wire per fan 350 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size not less than0.75 m of length not more than one meter with each fan complete all as specified and directed. (i) Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit schedule. (ii) taking down of fan, and re hanging measured under item No. 201 separately. 227 Material and labour for winding of ceiling fan motor 1400 mm sweep of any make with super enamelled copper winding wire of existing gauge (wt of copper winding wire per fan 350 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size not less than0.75 m of length not more than one meter with each fan complete all as specified and directed. (i) Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit schedule. (ii) taking down of fan, and re hanging measured under item No. 201separately. 228 Taking down aluminium/copper point wiring & including hard wood battens, surface conduit and board/ blocks etc or through conduits for light, socket or power point, fan point complete and making good the disturbed plaster surfaces of wall, floor, ceilingand painting 2 coat of white wash/distamber to match the existing surface, complete all as specified and directed. 229 M & L for Point wiring with PVC insulated FRLS 1.5 sq mm multi stranded copper conductor cable 1100 Volts grade drawn through and including surface PVC conduit/existing concealed conduit/PVC casing-caping etc as per site requirement onwalls / roofs / floors / ceiling etc and including provision of 1.5 sqmm copper cable as earth continuity conductor and connected to common earth dolly with all fitting and fixing accessories including sunk in cast iron / pressed steel terminal boxes (duly painted with two coats of anti corrosive paint out side and two coats of aluminium paint inside ) with 3.0 mm thick hylum brand laminated white bakelite sheet cover for mounting switches, sockets, fans regulators etccomplete for the following :-Make of wire: Polycab/Plaza/HavellsNote: (a) Switches, sockets outlets, Light fittngs, fans, bells & regulators shall be measured and paid for separetely). 230 All as per item No. 229here in before but forOne light point/fan point controlled by one way 5 Amp switch. 231 All as per item No. 229here in before but forOne light point controlled by two way 5 Amp switch. 232 All as per item No. 229here in before but for one bell point controlled by one way bell push. 233 All as per item No. 229here in before but forOne 3 pin socket out let 5 Ampon the same board 234 All as per item No. 229 here in before but for one switch socket outlet 3 pin 5 Amps on independent board 235 All as per item No. 229here in before but for Wiring with 2.5 Sqmm copper multistranded unsheathed cable and2.5 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently complete all as specified and directed. 236 All as per item No. 229here in before but for Wiring with 4 Sqmm copper multistranded unsheathed cable and4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently complete all as specified and directed. 237 Supply and Fix switch piano flush type 5 Amps240 volts single pole one way, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian 238 Supply and Fix switch piano flush type 5 Amps240 volts single pole two way, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian 239 Supply and Fix switch piano flush type 5 Amps240 volts bell push, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian 240 Supply and Fix shuttered socket outlet 3 pin 5 Amps, flush type, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian 241 Supply and Fix shuttered switch socket outlet 3 pin 5 Amps, flush type, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian 242 Supply and Fix shuttered switch socket outlet 2 in 1, 3 pin, 5 and15 Amps, complete all as specified and directed.Make : Anchor/Havells/L&T/Indoasian 243 S & F ceiling rose surface bakelight two to three terminal complete all as specified and directedMake : Anchor/Havells/L&T/Indoasian 244 S & F in repairfan regulator 120W,for ceiling fan complete all as specified and directed Make : Anchor/Havells/L&T/Indoasian 245 S & F2.5 mfd condensor for ceiling fan, complete all as specified and directed. Make : Epcos/ Asian/ Tyton 246 S & Felectric bell, AC 230 volt, single pole Ding Dong type complete all as specified and directed. Make :Anchor/Havells/L&T 247 M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 Sqmm drawn through in and incl suitable size surface PVC casing caping/PVC Conduit and all accessories fixed to wall/floors along with 4 Sqmm surface PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size.Note: (a)2 runs of 4 Sqmm cable along with one run of 4 Sqmm cable for earth conductor shall be measured as one lengthMake:- Havells/ Polycab/ Plaza. 248 S&F in replacementfactory madepowder coated distribution board VTPN, 4 way double doorMCCB DB includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DBcomplete all as directedMake : Indoasian/ Havells/ Legrand. 249 S&F in replacement distribution board MCCB four pole, 100 Amp ultimate breaking capacity 16 KAconforming to IEC -61439-1, complete all as specified and directed. Make : Legrand/ L&T/ Indo Asian 250 Supply and Fixing in repairs of 4 feet surface mounted batten type luminaire , lumen output of 2000 lumens, high efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle not less than 120° to ensure better uniformity with an operating voltage range from 140V-270V. The luminaire shall have a white extrusion housing with a poly carbonate diffuser to provide uniform light and sleek design with width not more than 22 mm. The luminaire shall have a CRI >80, Color temperature 6500K, THD <10% and PF >0.95,SDCM<5, IP20, IK02, Operating Temperature: -10 TO + 45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-55 HZ. The luminaire shall have flicker content<5% and shall have high and low cut off with auto restart feature.Driver Safety requirement stds: IS 15885-2-13. The luminaire shall be EMI/ EMC compliant and shall have a internal surge protection of 4 KV. The luminaire shall have Class-1 Electrical insulation, Class-B serviceability .The luminaire and driver shall be BIS approved, complete all as specified and directed.Make : Philips/ Bajaj / CG/Havells. 251 Supply and Fixin replacement ofsurface mounted Square/Roundfor LED 18W Watt downlights made of extruded Aluminium housing and high power LED light source withDriver clear diffuser with separate electronic driver with complete accessories all as specified and directed.Make : Philips/ Bajaj/ CG/Havells. 252 S&F in replacement factory madepowder coated distribution board SPN 12 way double door,includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DB conforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian 253 S&F in replacement distribution board MCCB four pole, 63 Amp ultimate breaking capacity 16 KAconforming to IEC -61439-1, complete all as specified and directed. Make : Legrand/ L&T/ Indo Asian 254 S&F in repairs 35/36 W (WH) LED Surface type2x2 ft luminaire with classic design & glare free soft illumination. housing with white high reflection powder coated (RAL9016) CRCA sheet. Glare free, Opal diffuser for symmetrical light distribution fixed in separate CRCA sheet frame held in with housing by screws for easy maintenance. High efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle of 100° to ensure better uniformity. Powered by an independent Isolated, SELF Output electronic LED driver (SMPS based constant current supply) efficiency of 85% with built-in Surge protection 3Kv. System Lumen Output of 3000 lumens.Make : Philips/ Bajaj/CG/Havells. 255 S&F in repairs LED bed side light /wall light/study lightenvironmentel friendly energy effcient of capacity3 W warm whiteetc,inbuilt drivercomplete with all accessories internally pre-wired swing type and including connecting up towith twin core twisted flexible copper conductor cable with suitable size complete all as directed . Make : Bajaj/ Philips / Wipro/CG 256 Supply & Fixing in replacement of electronic LED driver 2/3 W suitable for bed side light fitting as per site requirement complete all as specified and directed . 257 M & L for Point wiring with PVC insulated FRLS 1.5 sq mm multi stranded copper conductor cable 1100 Volts grade drawn into and including concealedrigid non mettalic PVC conduit/casing caping medium grade not less than 19/20 mm ( ISI marked ) with all fitting and fixing accessories including sunk in pressed steel chromium plated terminal boxes, concealed in wall/surface/roofs/floor/ceiling etc as per site requirement and making & matching the existing surface) white bakelite sheet cover for mounting switches, Sockets, Fan regulators etc or modular cover plate with frame including sunken boxes suitableto fix modular cover plate with frame, concealed in wall or 1.5 sq mm multi stranded copper conductor cable as continuous earth wire drawn with wiring and connected to common earth dolly complete all as specified and directed for the following :- Make of wire: Polycab/Plaza/HavellsNote:Blanking plate,Modular cover plate ,Switches, sockets outlets, Light fittngs, fans, bells & regulators shall be measured and paid for separetely). 258 All as per item No. 257 here in before but for one light point/fan/bell point controlled by one wayswitch. 259 All as per item No. 257here in before but for one light point controlled by twowayswitch. 260 All as per item No. 257here in before but for one bell point controlled by one bell push. 261 All as per item No. 257 here in before but for one 3 pin socket out 5 Ampon the same board 262 All as per item No. 257 here in before but for one switch socket outlet 3 pin 5 Amps on independent board 263 All as per Sl No 257 above but Wiring with 2.5 Sqmm copper multistranded unsheathed cable and 2.5 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently etc complete all as specified and directed. 264 All as per Sl No. 257 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently complete all as specified and directed. 265 Supply and Fixmodular switch1 way 6 Amp.1 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor/Indoasian 266 Supply and Fixmodular switch2 way 6 Amp.1 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor /Indoasian 267 Supply and Fixmodular switchbell push .1 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor /Indoasian 268 Supply and Fixmodular Socket, 6A - 2/3 pin combined 2 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor/Indoasian 269 Supply and Fixmodular switch1 way 16 Amp.1 module, complete all as specified and directed. Make :Legrand/ Crabtree/ Anchor /Indoasian 270 Supply and Fix modular Socket, 16A - 2/3 pin combined 2 module, complete all as specified and directed. Make : Legrand/ Crabtree/ Anchor/Indoasian 271 Supply and fix White cover plate with frame,2/3 module 272 Supply and fix White cover plate with frame,4 module 273 Supply and fix White cover plate with frame,8 module 274 Supply and fix White cover plate with frame,6 module 275 Supply and fix White cover plate with frame,12 module 276 S & F Modular fan regulator 120W, 2 Module for ceiling fan complete all as specified and directedMake : Legrand/ Crabtree/ Anchor 277 M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 Sqmm drawn through in and incl suitable size surface PVC casing caping/PVC Conduit and all accessories fixed to wall/floors along with 6 Sqmm surface PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size.Note: (a)2 runs of 6 Sqmm cable along with one run of 6 Sqmm cable for earth conductor shall be measured as one lengthMake:- Havells/ Polycab/ Plaza. 278 S&F in replacement factory madepowder coated distribution board SPN 8 way double door,includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DBconforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian 279 S & F MCB in replacement ofSPN 240 volts 40 to 63 Amps complete including taking down unserviceable fitting complete all as specified and as directed .Make : Legrand/ L&T/ Indo Asian. 280 S&F in replacementfactory madepowder coated distribution board TPN, 4 way double doorMCBDB includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DBcomplete all as directedMake : Indoasian/ Havells/ Legrand. 281 S & F in replacement TPN, MCB 40 to 63 Amp, 240 v, 50 Hz ACsuitable for ‘C’ curve, 10 KA breaking capacitycomplete conforming to IS 8828 of 1996, all as specified Make : Legrand/ L&T/ Indo Asian 282 S&F in repairs 35/36 W( WH) LED recessed type 2x2 ft luminaire with classic design & glare free soft illumination. housing with white high reflection powder coated (RAL9016) CRCA sheet. Glare free, Opal diffuser for symmetrical light distribution fixed in separate CRCA sheet frame held in with housing by screws for easy maintenance. High efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle of 100° to ensure better uniformity. Powered by an independent Isolated, SELF Output electronic LED driver (SMPS based constant current supply) efficiency of 85% with built-in Surge protection 3Kv. System Lumen Output of 3000 lumens.Make : Philips/ Bajaj/CG/Havells. 283 Supply & Fixing in replacement of electronic LED driver 35/36 W suitable for round ceiling light indoor fitting of make Philips/ crompton/ Bajaj, complete all as specified and directed . 284 Supply & Fixing in replacement of electronic LED driver 9/10 W suitable for round ceiling light indoor fitting of make Philips/ crompton/ Bajaj, complete all as specified and directed . 285 S & Fin replacement 7/9 watt LED lamp, complete all as specified and directed. Make : Philips/ Bajaj/ Crompton 286 S&F in replacement factory madepowder coated distribution board SPN 6 way double door,includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DBconforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian 287 S & F in replacement of MCB single pole 240 volts 6 to 32 Amps complete including taking down unserviceable fitting complete all as specified and as directed.Make : Legrand/ L&T/ Indo Asian. 288 S & F in replacement TP, MCB 40 to 63 Amp, 240 v, 50 Hz ACsuitable for ‘C’ curve, 10 KA breaking capacitycomplete conforming to IS 8828 of 1996, all as specified Make : Legrand/ L&T/ Indo Asian 289 Supply and Fixing in repairs of 2 feet surface mounted batten type luminaire , lumen output of 1000 lumens, high efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle not less than 120° to ensure better uniformity with an operating voltage range from 140V-270V. The luminaire shall have a white extrusion housing with a poly carbonate diffuser to provide uniform light and sleek design with width not more than 22 mm. The luminaire shall have a CRI >80, Color temperature 6500K, THD <10% and PF >0.95,SDCM<5, IP20, IK02, Operating Temperature: -10 TO + 45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-55 HZ. The luminaire shall have flicker content<5% and shall have high and low cut off with auto restart feature.Driver Safety requirement stds: IS 15885-2-13. The luminaire shall be EMI/ EMC compliant and shall have a internal surge protection of 4 KV. The luminaire shall have Class-1 Electrical insulation, Class-B serviceability .The luminaire and driver shall be BIS approved, complete all as specified and directed.Make : Philips/ Bajaj / CG/Havells. 290 Refixingexisting serviceable LED light fitting fixture any capacity and of any type complete with all accessories internally pre-wired and including connecting up to ceiling rose with twin core twisted flexible copper conductor cable of suitable size after cleaning all dust etc. completeall as specified and as directed . 291 S&F in repairs 35/36 W (WH) LED recessed type1X4 ftluminaire with classic design & glare free soft illumination. housing with white high reflection powder coated (RAL9016) CRCA sheet. Glare free, Opal diffuser for symmetrical light distribution fixed in separate CRCA sheet frame held in with housing by screws for easy maintenance. High efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle of 100° to ensure better uniformity. Powered by an independent Isolated, SELF Output electronic LED driver (SMPS based constant current supply) efficiency of 85% with built-in Surge protection 3Kv. System Lumen Output of 3000 lumens.Make : Philips/ Bajaj/CG/Havells. 292 S&F in replacement factory madepowder coated distribution board SPN 4 way double door,includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DB conforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian 293 S & F MCB in replacement ofSPN 240 volts 32 Amps complete including taking down unserviceable fitting complete all as specified and as directed .Make : Legrand/ L&T/ Indo Asian. 294 S & F in replacement of MCB single pole 240 volts 40 to 63 Amps complete including taking down unserviceable fitting complete all as specified and as directed .Make : Legrand/ L&T/ Indo Asian 295 Excavation in trenches not exceeding 1.5 mtr in width and not exceeding 1.5 mtr in depth and getting out for laying of cables up to proper level and laying of pipelines etcinsoft/loose soil, complete all as specified and directed. 296 Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick, complete all as specified and directed. 297 Removing surplus excavated material (soil) not exc 50 meter and depositing where directed at a level not exc 1.5 meter above the starting point, complete all as specified and directed. 298 Material and labour for Spreading ribbed soil in trenches as in cable cushioning all as per IS 1255-1983, complete all as specified and directed.Note :- (i)Excavated approved soil shall be ribbed by using sieve to separate composite particles etc. as per IS and refilling in trenches before laying of cable 8 CM and 15 CM after laying of cable. This is then gently punned down to a depth of 10 cm above the top of upper most cable (ii) For the purpose of measurement only punned thickness shall be considered for payment. 299 Material and labour for well burnt bricks ‘B’ class as mechanicalprotection to under ground cables laying with length of the bricks equal to the width of the trench, complete all as specified and directed. 300 Material and labour for Cutting existing road/PCC/Drain for laying of GI or any type of pipe including necessary earthwork, excavation exc 600mm depth but not exc 1mtr depth, 800 mm wide including making good existing surface with 150 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate, complete all as specified and directed. Note :-The tenderer shall take into consideration for following points while quoting rate for this item andthe unit rate is deemed to be inclusive for :-(i) Earth work and excavation in any type of soil(ii) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick ,complete all as specified and as directed.(iii) Removing excavated material out side MD land.(iv)Laying of any type/any bore of pipe in trenches including taking down existing unserviceable pipe. Supply of pipe shall be measured and paid separately(v)150 mm thickPCC 1:2:4 type B1 using 20mm graded stone aggregate as inroad to make good existing disturbed surfaces. 301 Material and labour in repair for 4 core 10 Sqmm XLPE insulated heavy duty electric cable with aluminium single stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells, Polycab, RPG Asian 302 Material and labour in repair for 4 core 16 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells/Polycab/RPG Asian 303 Material and labour in repair formaking straight through joint with suitablejointing kit consisting of water proof adhesivesfor UG cable of size 4 core 10 Sqmm to 16 Sqmm, complete all as specified and directed. 304 Supply only of GI pipe light grade for cable protection of size 50mm bore with fittings, complete all as specified and directed. 305 Disconnecting of burnt/ damaged cables from panels/ junction boxes etc, cutting out the burnt out ends, making new end joints by supply and fixing new aluminium lugs/ insulation tape etc and reconnecting using new nuts/ bolts/ washer etc and restoring three phase and neutral in the junction box, complete all as specified and as directed for thecable sizefrom 10Sqmmto 16 Sqmm 3.5 core of underground LT armoured cables.Note :- Earth work required for extending the incoming/ outgoing cable in junction box/ panel board etc shall deemed to be included in the unit rate quoted. 306 Supply, installation, testing and commissioning LTFeeder pillar box double door CPRI Testedof Size 400X250X350mmsuitable for 3 phase 415 Volts of suitable size out door made out 3.15mm thick CRCA sheet of outdoor of panel with angle iron frame of size 32x32x5mm cubical type complete with aluminium bus bar 100 Amp and including PCC foundation as per site requairment to accomodated to the following.INCOMING(a)MCB TPN32 Amp 10 KA - 01 No. (b)LEDindicating lampR-Y-B - 03 Nos. OUTGOING(a) Weather Proof panelPlug and shocket angled type IP 67three Phase 3P+N +E, 20 Amp - 01 No(b) Weather Proof plug and shocket angled type IP 67 Single Phase 2P+E , 20 Amp- 01 No.(a)MCB TPN20 Amp 10 KA - 01 No. (a)MCB SPN20 Amp 10 KA - 01 No. 307 M &L for PCC (1:3:6) type C1 (using 20mm graded stone aggregate) as in copping to poleincluding necessary form work slightly rounding or squaring, complete all as specifiedand as directed. 308 M & L for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundation and mass concrete for poles and filling around fencing posts etc, complete all as specified and as directed 309 Supply & Erecting Mild steel tubular swaged pole 9 meter long 410, SP-31 complete with cast iron base plate, bracket, finial taper plug, bolt, nuts & screws and painted on both side (internally & externally), external surface painted with two coat of aluminum paint over coat of primer and painting with blackup to 1.5 meter from top of PCC 1:3:6 using 20 mm graded stone aggregate coping white colour paint as in strips of equal width with marking pole numbers by using one coat of synthetic enamel paint including necessary PCC 1:4:8 with 40 mm graded stone aggregate as in foundation and coping as per TD drawing including dismantling of old damaged pole complete all as specified and as directed.Note (i)Excavation, earth work and PCC work for embedding pole shall be measured and paid seperately.(ii) Pole upto 1.5 m top of copping shall be painted with 2 coats of black and white strips alternate 30cm each over one coat of red oxide primer (iii) Steel tubular pole above 1.5 m shall be painted with 2 coats of aluminium paint over a coat of red oxide primer. The rate for above items shall be deemed to be inclusive in the quoted rate. 310 Supply and fix in repair weather proof PVC junction box approved by CPRI for street light control box made out of not less than 2mm thick and size 250mm x 200 mm x 105mm (approx) complete with hinged door locking arrangement and consisting of 2 Nos of suitable size cable glands consisting of 01 No. panel mounted connector 4 pole 32A-1 No, MCB SP 6A 10KA-01No, including connecting up with the electrical connections and fixing with clamps etc complete and all as specified anddirected. 311 Supply and fix 1100 Volts grade heavy duty flat weather proof twin core cable of size 4 Sqmm with multistrand aluminium conductor including taking down of old one complete all as specified and directed. Make: Plaza/Polycab/ Finolex/Havells 312 Supply and fixing in repair LED flood light 150 watt made up of die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP 66 protection and system efficiency ≥ 125 LPW with option for 3000K 10 KV SPD corrosion resistant complete with driver and lampProtection including street light fitting bracket nuts, bolts, washers complete, all as specified and directed. Make:Halonix/Philips/CG/Bajaj 313 Supply and fix in repair bracket for street light fitting made out of40 mm dia light grade GI tubing bent to required shape 1.5m long including necessary GI clamps, nuts bolts and washers and fixing to the pole etc complete all as specified and directed. 314 Supply and fixing in repair Round spherical garden lighting, post top lantern having B22 holder suitable for LED bulb10 watt, 220 volt,50HZ,IP65 including suitable of GI tubing ,length as per site requirement on gate pillars/ garden lights for fixing the lamp, wiring with 1.5 Sqmm PVC insulated strandedcopper conductor includingPCC work for fixing, of light fitting complete all as specified and directed.Make: Philips/ Havells/Bajaj/CG. 315 Suply and fix in repairs LED decorative post top lantern fitting 40W, 230V AC with IP 65 protection and resistant to impact and corrosion with necessary electrical connection completeall as specified as directed. Make: Bajaj / Philips/Halonix/ CG 316 Supply and fix in repair weather proof PVC junction box approved by CPRI for street light control box made out of not less than 2mm thick and size 140x140x100mm (approx) complete with hinged door locking arrangement and consisting of 2 Nos of suitable size cable glands consisting of 01 No. panel mounted connector 4 pole 32 Noincluding connecting up with the electrical connections and fixing with clamps etc complete and all as specified anddirected. 317 Supply and fix 1100 Volts grade heavy duty flat weather proof twin core cable of size 6 Sqmm with multistrand aluminium conductor including taking down of old one complete all as directed and specified. Make: Plaza/Polycab/ Finolex/Havells 318 Supply and fixing LED flood light 100 watt 230 V AC outdoor type including necessary bracket with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp including taking down of old unserviceable fitting of any capacity.Make :Bajaj/Philips/CG/Halonix. 319 Supply and fixing in repair IP65 rated LED Bollard with robust design and efficient light distribution 10 watt on existing pipe of any size and height with all accessories prewired fixed with FI clamps nuts bolts etc., including taking down existing fittings all as specified and directed Make : Crompton/ Halonix/Bajaj/ Philips 320 Suply and fix in repairs LED decorative post top lantern fitting 25 W, 230V AC with IP 65 protection and resistant to impact and corrosion with necessary electrical connection completeall as specified as directed. Make: Bajaj / Philips/Halonix/ CG 321 Supply and fix 1100 Volts grade heavy duty flat weather proof twin core cable of size 10 Sqmm with multistrand aluminium conductor including taking down of old one complete all as directed and specified. Make: Plaza/Polycab/ Finolex/ Havells 322 Material and labour in repair for 3 ½ core 25 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells/ Polycab/ RPG Asian 323 Material and labour in repair formaking straight through joint with suitablejointing kit consisting of water proof adhesivesfor UG cable of size 3.50 core 16 Sqmm to 25 Sqmm, complete all as specified and directed. 324 Servicing/ Periodical maintenance of following capacity DG Set of any make consisting of complete servicing and checking entire system as per manufacturers catalogue including testing complete with replacing of minorconsumables itemslike grease, nut bolts etc during conducting periodic servicing as per the manufacturers recommendation at the time of routine monthly checks. Capacity 20KVA DG Set - Location:-street lights CQAE Area - 01 No Maintenance Schedule of DG Sets :- The contractor shall carried out following activity during ofthe period of contract :- 325 (a)Daily maintenance of DG Sets to be carried out :- 326 (i) Clean the external surface of the DG set. 327 (ii)Check engine oil level. 328 (iii) Check engine coolant level. 329 (iv) Check fuel in the tank. 330 (v)Check all nuts and bolts. 331 (vi) Check tension of fan belts. 332 (vii) Check batteries and battery connections. 333 (viii)Check fuel lines and fuel tank. 334 (b)Weekly maintenance of AMF Panels :- 335 (i) Checking all electrical connections. 336 (ii)Checking all contact points/ Bus bars. 337 (iii) Checking timers (AC/ DC). 338 (iv) Checking all selector switches (voltmeter and Ammeter). 339 (v)Check RPM, Voltage, Amps and Hz. 340 (vi) Checking indicator lamps. 341 (vii) Checking main auxiliary contacts and relays. 342 (viii)Checking contact coils. 343 (ix)Checking, volt/ amps/ energy/ PF/ KWH meters/ CTs. 344 (x) Checking auto/ manual functions. 345 (xi)Check and tight screws and bolts. 346 (xii)Check battery charger output voltage. 347 (xiii) Cleaning the panel. 348 (xiv) Checking all MCCBs and fuses. 349 (xv) Checking alarms and hooter. 350 (c) Monthly maintenance of DG Sets to be carried out :- 351 (i)Check oil bath cleaner oil level. 352 (ii) Check for proper tension in the belts. 353 (iii) Check starting battery electrolyte level and specific gravity. 354 (iv) Check the fuel lines from the tank for leakages. 355 (v) Check the end cover of the alternator and tighten the bolts. 356 (vi) Check physically the exhaust silencer for rigidness. 357 (vii) Check the water hoses for leakages if any. 358 (viii) Drain sediment from fuel filter & fuel tank. 359 (ix) Check dry type air filter element and clean. 360 (x) Check engine alternator coupling and mounting bolts. 361 (xi) Tight all bolts and nuts in alternator terminal box. 362 (xii)Check for any unusual sound during cranking of the engine. 363 (xiii)Check for any fuel/ water leakages. 364 (xiv)Check for any unusual vibrations. 365 (xv)Check proper charging of battery. 366 (xvi)Check exhaust system for any leakages. 367 (xvii) Check for proper circulation of coolant/ cooling of engine. 368 (xviii) Check physically the exhaust silencer for rigidness. 369 (xix) Check throttles linkage. 370 (xx) Checking to electric control panel throttle linkage. 371 (xxi) Supply and greasing to all bearing & movable parts. 372 (d)Quaterly Schedule to be carried out :- 373 (i)Checking of hydraulic governor oil level and toping up level. 374 (ii) Clean the crank case breather. 375 (iii)Check battery charging system & topping up electrolyte and maintenance of specific gravity. 376 (iv) Checking electric connection & generator control panel. 377 (v) Greasing to all bearing and movable parts. 378 Note :- The unitrate quoted is deemed to be inclusive of the followings :- 379 (a)DG Sets are placed at various locations of CQAE (WE). Therefore,the bidders areadvised to visit the location of DG Sets before quoting the tender. 380 (b)Servicing/ repair of DG Set shall be carried out by authorised dealer/ agency of manufacturer as approved by Engineer-in-Charge and where service/ repair is being carried out at site shall be under the expert supervision of authorised service agent. 381 (c) The make of DG sets are Kirloskar/ Greaves Cotton 382 (d)Filling of DHPP (N) in all mentioned DG Sets at various locations will be the responsibility of the contractor. However, DHPP (N) will be issued by MES. The amount for filling of DHPP (N) in DG sets is deemed to be inclusive in unit quoted rate. 383 (e) DHPP (N) required at the time of maintenance/ testing will be issued by MES. 384 (f)Representative of contractor shall maintain & update the maintenance/ breakdown register regularly and same will be checked by Engineer-in-Charge periodically. 385 (g)The monthly check shall be done once in a month but whenever breakdown occurs in DG set, the contractor has to attend all complaint unlimitedly through authorised service agent of the equipment/ machinery. 386 (h)The unit rate is deemed to be included for Cleaning of the surrounding area of DG set 5 mtr from plinth protection ofE/M installations includingremoving of accumulated earthof any width and depth upto 15cm cleaning / Cutting the grass with hand operated petrol/ kerosene driven grass cutting machine andremoving thegrass waste to outside MD land. 387 (j)In case of minor defect, entire Job shall be completed within 06 hrs from the time of registration of complaint, failing which penalty charges @ Rs. 500/- per hours shall be recovered. 388 (k)In case of major defect, the period for attending of complaint shall be decided by the GE/EIC by accessing extent of repair required through joint inspectionby Engineer-in-Charge and authorised service agent of the equipment at the site. If complaint is not rectified within the stipulated period and the GE is not satisfied with the reason for delay, then penalty at the rate of Rs. 600/- per hours shall be deducted from the dues of the contractor. 389 (l)Please note that above penalty is exclusively other than the condition 67 of IAFW - 2249 and shall be treated as interim condition of the contract and shall be enforce above as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt. 390 (m) The decision of the Accepting Officer in this regard shall be final and binding. 391 (n)The contractor shall be responsible to maintain the DG set in serviceable condition for entire contract period. 392 Description all as per Sl Item No 324 here in before but for Capacity 40KVA DG Set- Location:-Pump House-1 No 393 Description all as per Sl Item No 324 here in before but for capacity125 KVA DG set Location:-Tech building :- 1 No 394 Description all as per Sl Item No 324 here in before but for capacity 250 KVA DG set Location:-Tech building :- 1 No 395 Dismantling/ taking down complete radiator assembly of 20 KVA to 40 KVA DG Set and transportation to authorised workshop for following repairs :-(a) Opening the radiator assembly with brazing/ welding for repair/ service.(b)Cleaning of all water tube with diluted solution of HCL and cleaning with water pressure and removing the sludge and dust from inside the tank by flushing out.(c)Determining the leak/ puncher in radiator tubes.(d)Repair of fins by soldering/ brazing.(e)Repair of bottom brass water tank by soldering/ brazing.(f) Repair of radiator hose assembly.(g)Fixing the complete radiator assembly to its original position and testing complete all as specified and directed by Engineer-in-Charge. 396 Dismantling/ taking down complete radiator assembly of 125 KVADG Set and transportation to authorised workshop for following repairs :-(a) Opening the radiator assembly with brazing/ welding for repair/ service.(b)Cleaning of all water tube with diluted solution of HCL and cleaning with water pressure and removing the sludge and dust from inside the tank by flushing out.(c)Determining the leak/ puncher in radiator tubes.(d)Repair of fins by soldering/ brazing.(e)Repair of bottom brass water tank by soldering/ brazing.(f) Repair of radiator hose assembly.(g)Fixing the complete radiator assembly to its original position and testing complete all as specified and directed by Engineer-in-Charge. 397 Taking down old unserviceable self motorof capacity 20 KVA to 40 KVAand carrying to authorised work shop for servicing includingreplacment of unserviceable spare parts Brush, holder, solonoid switch, armature bush, filed coil complete and refixing, testing complete all as specified and directed. 398 Taking down old unserviceable self motorof capacity 125 KVAand carrying to authorised work shop for servicing includingreplacment of unserviceable spare parts Brush, holder, solonoid switch, armature bush, filed coil complete and refixing, Testingcomplete all as specified and directed. 399 Removing and replacing the old unserviceable one with new AVR (Automatic Voltage Regulator) suitable for Kirloskar curve of capacity 20 to 40KVA having input voltage 2 phase + neutral sensing voltage 415 output voltage 95V DC, output current 4A DC voltage regulation +/- 1 % average volts, over excitation current tripping, fuse protection 4A, fast acting and frequency 50 Hzcomplete all as specified and directed. 400 Removing and replacing the old unserviceable AVR (Automatic Voltage Regulator) suitable for capacity 125KVA having input voltage 2 phase + neutral sensing voltage 415 output voltage 95V DC, output current 4A DC voltage regulation +/- 1 % average volts, over excitation current tripping, fuse protection 4A, fast acting and frequency 50 Hzcomplete all as specified and directed. 401 Taking down 12/ 24 volts self starter assembly from DG set and transporting to its authorised workshop for repair/ servicing by replacement of defective spare parts such as carbon brush, carbon ring, bearing, bush, defectine wiring, winding and soldering after repair including testing after repair/ service and re-installation in original position for satisfactory functioncomplete all as specified and directed. 402 Supply and fixingin replacement self starter 12 Volts of DG Sets complete all as specified and directed. 403 Supply and fixingin replacement battery cable assembly (-ve & +ve) complete all as specified and directed.Note :- Items like clamp, lugs, nut, bolts and copper cable of size 25 sqmm upto 1 mtr required for connection is deemed to be inclusive in unit rate quoted. 404 Supply and fixingin replacement maintenance free lead acid sealed battery (SMF) 12 volts 90 AH complete all as specified and as directed.Make : EXIDE. / Amaron/ Amar RajaNote :-Old battery shall be deposited in MES store yard. 405 Supply and fixingin replacement maintenance free lead acid sealed battery (SMF) 12 volts 180 AH complete all as specified and as directed.Make : EXIDE. / Amaron/ Amar RajaNote :-Old battery shall be deposited in MES store yard. 406 Material and labourOpening disconnecting LT Cable connections with care from Auto-Main Failure Panel and checking throughly with Fault Detector Instrument at Site and replacement of Minor Defective Parts as required at Site suitable for 20 KVA to 40 KVA DG Setcomplete all as specified and as directed. 407 Material and labourOpening disconnecting LT Cable connections with care from Auto-Main Failure Panel and checking throughly with Fault Detector Instrument at Site and replacement of Minor Defective Parts as required at Site suitable for 125 KVA DG Setcomplete all as specified and as directed. 408 Supply and fix in replacement of selectorswitch 16 A 2 pole 2 way complete all as specified and as directed. 409 Supply and fix in replacement of selectorswitch 16 A 3 pole 3 way complete all as specified and as directed. 410 Supply and fix in replacement of RPM meter assembly complete set including rubber gasket, wire as per sample complete all as specified and as directed. 411 Supply and fix in replacement of add-on auxilury contactorblock 2No-2NC complete all as specified and as directed. 412 Supply and fix in replacement of electronictimer delay of range12 sec to 120 sec operational in 240V AC supply complete all as specified and directed. Make:- Selectron or equivalent 413 Supply and fixingin replacement of Relay for control contactor AC control std. Coil Voltage - 24, 110, 240, 415V 50HZ (2 NO + 2 NC) complete all as specified and directed. Make L& T / BCH/ ABB 414 Supply and fixing in replacement indicator lamp RYB complete all as specified and as directed. 415 Supply and fix in replacement of push button for Start/Stop switch allas per sample complete all as specified and as directed. 416 Supply and fix in replacement of Relay for single phase preventor 6 wire suitable for all mode operation all as directed. 417 Supply and fix in replacement ofelectronic Oil pressure sensor complete with wiring, connectors, bottle thimble all as directed 418 Supply and fix in replacement of 12V/24V 11 pin PLA relay with base all as specified and as directed. 419 Supply and fix in replacement of radiator hose of any capacity complete all as specified and directed. 420 Supply and fix in replacement of oil drain hose set complete all as specified and as directed. 421 Supply and fix in replacement of fuelhose set nylon type of any capacity complete all as specified and directed. 422 Material and labourfor replacement of door hinges of Acoustic enclosureheavy duty metal type for Left/Right side complete all as specified and directed. 423 Supply and fixingMCCB 200A, 36 KA, 4 Pole, 415V including taking down unserviceable one, complete all as specified and as directed. Make - L &T/Havells/Indoasian 424 Supply andfix in replacement of water pump assembly of water cooling system of DG set any capacity complete all as specified and directed. 425 Supply and fix in replacement of electronic water temp gauge sensor double pin in byepass complete with wiring, connectors, bottle thimble complete all as specified and directed. 426 Supply and fix in replacement of radiatorfan belt suitable for any capacity DG set complete all as specified and as directed. 427 Material and labourfor distilled water in 5 ltr/ 2 ltr capacity sealed cane to be filled in batteries complete all as specified and directed. 428 Material and labourof electrolyte for battarycomplete all as specified and directed. 429 Supply and fixingMCCB 63A, 16 KA, 4 Pole, 415V including taking down unserviceable one, complete all as specified and as directed. Make - L &T/Havells/Indoasian 430 Supply and fixingin replacement stop solenoid assembly 12V/ 24V DC for micro pump (two coil) heavy duty electrical control make energise to stop of DG Setscomplete all as specified and directed.Make :- Kirloskar or existingbrand of defective components or any reputed suitable make as approved by GE 431 Disconnecting the existing battery of capacity 12V 90 to 180 AH from the DG set, taking it to battery workshop, draining out the complete unserviceable electrolyte acid from the battery, filling up with new Electrolyte acid to the required level, charging the battery, testing the battery for correct specific gravity, bringing back to the location, connecting to DG set, start the engine for satisfactory function all as directed by Engineer-in-charge. 432 Supply and fixing in replacement of brass terminal suitable for 12 Volts, 90/180 AHbattery complete all as specified & directed. 433 Supply and fixingBattery charging alternator assembly 12 Volts of DG Sets complete including taking down existing one complete all as specified & directed. 434 Material and labourRepairs to 12V battery charging alternator assembly by removing, dismantling, replacing the unserviceable burnt rotor and stator assembly completly including insulation sleeves and refixing to the engine and testing to the satisfaction of DC volts & Ampsby charging of battery complete all as specified & directed. 435 Supply and fix in replacement of lubrication oil filter element with O ring of Make MICO / Kirloskar / Mahle/ Cummins as required at site for 20KVA capacities of DG Sets complete all as specified and as directed. 436 Supply and fix in replacement of lubrication oil filter element with O ring of Make MICO / Kirloskar / Mahle/ Cummins as required at site for 40KVA capacities of DG Sets complete all as specified and as directed. 437 Supply and fix in replacement of lubrication oil filter element with O ring of Make MICO / Kirloskar / Mahle/ Cummins as required at site for 125KVA capacities of DG Sets complete all as specified and as directed. 438 Supply and fix in replacement of lubrication oil filter element with O ring of Make MICO / Kirloskar / Mahle/ Cummins as required at site for 250 KVA capacities of DG Sets complete all as specified and as directed. 439 Supply and fixingin repairs earth Fault relay complete all as specified and directed. 440 Supply and fix in replacement of turbo cooler rubber hose of any capacity complete all as specified and as directed. 441 Material and labourfor lubrication oil SAE 15 W - 40grade API CI 4 plustype in sealed container for DG set Top up and change the oil in the sump after completely flushing the old oil from the tank/sump and cleaning of the same complete all as specified and as directed. (Make :Castrol/Valvoline/Servo) 442 Supply and fix in replacement of oil seal assembly of any capacity as per sample complete all as specified and directed. 443 Material and labour for 3 ½ core 70 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole complete including taking down unserviceable one all as specified and directed. Make : Havells/Polycab/ RPG Asian 444 Material and labour for 3 ½ core 95 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole complete including taking down unserviceable one all as specified and directed. Make : Havells, Polycab, RPG Asian 445 Material and labour in repair formaking straight through joint with suitablejointing kit consisting of water proof adhesivesfor UG cable of size 3.50 core 70 Sqmm to 95 Sqmm, complete all as specified and directed. 446 Material and labour forBoring of holes under road, pavement hard standings by trenchless technology using ultra sound technique and necessary machine including HDPE pipes upto 100 mm dia suitable for 0.4 Mpa working pressure, complete all as specified and directed. 447 Disconnecting of burnt/ damaged cables from panels/ junction boxes etc, cutting out the burnt out ends, making new end joints by supply and fixing new aluminium lugs/ insulation tape etc and reconnecting using new nuts/ bolts/ washer etc and restoring three phase and neutral in the junction box, complete all as specified and as directed for thecable sizefrom 70 Sqmmto 95 Sqmm 3.5 core of underground LT armoured cables.Note :- Earth work required for extending the incoming/ outgoing cable in junction box/ panel board etc shall deemed to be included in the unit rate quoted. 448 Supply, installation, commissioning and testing of factory assembled, floor mounted, free standing type tested LT Feeder pillar panels, with canopy, as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accordance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS compliant & Halogen free. The manufacturer of boards/panels shall submit a copy oftype test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thremoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be minimum 200mm for air circulation & to minimize temp rise. Panel should be fitted with one No.polycarbonate IP 65, 9 W LED translucent bulk head luminaire color temp not less than 6500K, PF >0.95 under canopy for easy maintenance. Panel should be fitted outside with one No. of 16 A 3 Pole IP65 industrial socket and 01 No. of 32A 5P IP 65 industrial socket. 3 Phase and neutral 400 Amp current carrying capacity of Aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20 mm graded crushed stone aggregate for bedding upto a height of 45 CM above ground level, including dismanting and taking out U/s LT panel board and reconnecting existing LT UG Cable with new panel board all as directed :- 449 (a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 250 Amp, 36 KA- 01 No (Incomer). (b) MCCB with thermal magnetic release 4 Pole, 415 V of capacity100 Amp,16 KA- 02 Nos.(c) MCCB with thermal magnetic release 4 Pole, 415 V of capacity63 Amp,16 KA- 02 Nos.(d) Multifunction Meter (V,I,PF) with suitable capacity of CTs- 01 No(e) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set.(f) Space for spare feeder - 01 No. Note :-(i) The Contractor shall submit the drawing for approval of GE before executing the work.(ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S.(iv) MCCB should be ICu =100% ICs.(v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS). 450 Supply, installation, commissioning and testing of factory assembled, floor mounted, free standing type tested LT Feeder pillar panels, with canopy, as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accordance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS compliant & Halogen free. The manufacturer of boards/panels shall submit a copy oftype test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thremoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be minimum 200mm for air circulation & to minimize temp rise. Panel should be fitted with one No.polycarbonate IP 65, 9 W LED translucent bulk head luminaire color temp not less than 6500K, PF >0.95 under canopy for easy maintenance. Panel should be fitted outside with one No. of 16 A 3 Pole IP65 industrial socket and 01 No. of 32A 5P IP 65 industrial socket. 3 Phase and neutral 400 Amp current carrying capacity of Aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20 mm graded crushed stone aggregate for bedding upto a height of 45 CM above ground level, including dismanting and taking out U/s LT panel board and reconnecting existing LT UG Cable with new panel board all as directed :- 451 (a) MCCB with thermal magnetic release 4 Pole ,415 V of capacity 250 Amps ,36 KA- 01 No (Incomer).(b) MCCB with thermal magnetic release 4 Pole ,415 V of capacity 63 Amps ,10 KA- 04 Nos.(c ) Multifunction Meter (V,I,PF) with suitable capacity of CTs- 01 No.(d) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set.(e) Space for spare feeder -01 No.Note :-(i) The Contractor shall submit the drawing for approval of GE before executing the work.(ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S.(iv) MCCB should be ICu =100% ICs.(v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS). 452 Material and labourreplacement of existing unserviceable door lock arrangement to DG set canopywith new door lock & key etc as per existing size & type complete all as specified & directed. 453 Supply and fix in replacement of electronic water temp gauge sensor single pin for engine block complete with wiring, connectors, bottle thimble complete all as specified and directed. 454 Supply and fixing in repairs door glass and beading for DG Set of any capacity complete all as specified and directed. 455 Supply and fixing in repairs 24V DC solenoid switch complete all as specified and directed. 456 Material and labourfor Urea which contain 32.5% urea and 67.5 % deionized water complete all as directed . 457 Supply and providing coolant concentrate in sealed container for top up complete all as specified and directed.Make : Valvoline/ Fleet guard/ Mahle 458 Supply and fix in replacement of electronic Fuel Level sensor complete with wiring, connectors, bottle thimble complete all as specified and directed. 459 Supply and fix in replacement of radiator mounting pad set of any size complete all as specified and directed. 460 Supply and Fix in replacement of temeprature guage of any capacity complete all as specified and as directed. 461 Supplyand Replacement of fuel filter element with O ring of Make MICO / Kirloskar / Mahle/ Ashok Leyland/ Cummins as required at site for 20 KVA capacities of DG Setsall as directed by Engineer-in-Charge. 462 Supplyand Replacement of fuel filter element with O ring of Make MICO / Kirloskar / Mahle/ Ashok Leyland/ Cummins as required at site for 40 KVA capacities of DG Setsall as directed by Engineer-in-Charge. 463 Supplyand Replacement of fuel filter element with O ring of Make MICO / Kirloskar / Mahle/ Ashok Leyland/ Cummins as required at site for 125 KVA capacities of DG Setsall as directed by Engineer-in-Charge. 464 Supplyand Replacement of fuel filter element with O ring of Make MICO / Kirloskar / Mahle/ Ashok Leyland/ Cummins as required at site for 250 KVA capacities of DG Setsall as directed by Engineer-in-Charge. 465 Supply and fixing in repairs mechanical type diesel float switch assembly complete all as specified and directed. 466 Supply and fixingin replacement Cooling Fansuitable for DG Set 125 KVA capacity, complete all as specified and as directed. 467 Supply and fixingin replacement Cooling Fansuitable for DG Set 20 to 40 KVA capacity, complete all as specified and as directed. 468 Supply and fix in replacement of flush type LED Digital multi functional meter withparameter (V,I,PF) suitable for DG set AMF panelcompleteof Model A class 1 complete all as specified & directed. 469 Supply and fixingin replacementcontactor 4 pole,with 1 NO + 1 NC aux contacts and coil voltage 240 V/415 volt suitable for AMF Panels of 125 KVADG Set complete all as specified and as directed. MAKE : L&T/BCH/Schneider 470 Supply and fixingin replacementcontactor 4 pole,with 1 NO + 1 NC aux contacts and coil voltage 240 V/415 volt suitable for AMF Panels of 40 KVADG Set complete all as specified and as directed. MAKE : L&T/BCH/Schneider 471 Supply and fixingin replacementcontactor 4 pole,with 1 NO + 1 NC aux contacts and coil voltage 240 V/415 volt suitable for AMF Panels of 20 KVADG Set complete all as specified and as directed. MAKE : L&T/BCH/Schneider 472 Disconnecting the electrical connection from AMF Panel, taking down DG set of cap 20 to 40KVA for major overhauling of engine and transportationto authorised workshop forreplacement of piston assembly complete-4 sets, exhaust valve, cyilinder liner, inlet and out let valves, sealing cap, copper washers,thermostat elements, spin of filter for lubrication oil, oil seal, valve tappet, gasket for cylinder head, bush for injector, gasket for exhuast manifold,joint for bearing housing, joint for delivery volute, turbo repair kit complete all as specified & directed. 473 Supply and fixing in repairs electronic type diesel float switch assembly complete all as specified and directed. 474 Supply and fix in replacment of valve door packing of any capacity complete all as specified and directed. 475 Supply and fix in replacement of Auto source transfer controller unitsuitable for DG set AMF panel of any capacity and as per existing Make complete all as specified and directed. 476 Supply and fixingin repairs change over switch 125 Amps capacity 4 pole 3 phase with enclosure complete all as specified and directed. Make-Legrand/ L&T / Indoasian 477 Supply and fixingin replacement microprocessor based AMF controller unit for AMF Panel flush mounting type suitable for DG Set 20 to 40 KVA capacity as per existing make complete all as specified and directed. 478 Supply and fixingin replacement microprocessor based AMF controller unit for AMF Panel flush mounting type suitable for DG Set 125 KVA capacity as per existing make complete all as specified and directed. 479 Supply and fix in replacement of Air filter elementinner and outer as required at site with O ring of Make MICO / Kirloskar / Mahle/ Cummins as required at site for 20 KVA capacities of DG Sets complete all as specified & directed. 480 Supply and fix in replacement of Air filter elementinner and outer as required at site with O ring of Make MICO / Kirloskar / Mahle/ Cummins as required at site for 40 KVA capacities of DG Sets complete all as specified & directed. 481 Supply and fix in replacement of Air filter elementinner and outer as required at site with O ring of Make MICO / Kirloskar / Mahle/ Cummins as required at site for 125 KVA capacities of DG Sets complete all as specified & directed. 482 Supply and fix in replacement of Air filter elementinner and outer as required at site with O ring of Make MICO / Kirloskar / Mahle/ Cummins as required at site for 250 KVA capacities of DG Sets complete all as specified & directed. 483 Supply and fixingin repairs change over switch 63 Amps capacity 4 pole 3 phase with enclosure complete all as specified and directed. Make-Legrand/ L&T / Indoasian 484 Supply and fixingin replacement ofwiring of AMF panel of capacity DG set including copper wire ,PVCwire holder and other connected items suitable for DG Set 20 to 40 KVA capacity as per existing make complete all as specified and directed. 485 Supply and fixingin replacement of Fly wheel ringincluding nuts and bolt suitable for DG Set 20 to 40 KVA capacity as per existing make complete all as specified and directed. 486 Supply and fixingin replacement of Fly wheel ringincluding nuts and bolt suitable for DG Set125 KVA capacity as per existing make complete all as specified and directed. 487 Surface dressing in hard / dense soilnot exceeding 15 cm deepand clearing all the grass weeds etc in the sub station yards after removing stone aggregate asideall as directed at site including setting / spreading back the aggregate complete all as specified and directed at site.Note:- (i)Additional stone aggregate required shall be measured and paid separately under relevant items of this schedule.(ii)The rate also deemed to be included for labour (iii) The sub station yards shall be kept cleanthrough out the contract period by removing the grass/weeds as many as times required depending on the growth of the grass. (iv)The rates shall be deemed to includesthe cost of removing two time the grass,weeds,debris,excess soil etc to a distance not less than 50 M and keeping the excavated surface clean and levelled all as directed. 488 Supply and laying of GI pipe light grade for cable protection of size 80 mm bore complete with fitting completeincluding taking down unserviceable one all as inspecified and directed. 489 Material and labour for 3 ½ core 185 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheather laying in trenches/cable ducts, fixed to wall/pole complete including taking down unserviceable one all as specified and directed. Make : Havells/ Polycab/ RPG Asian 490 Disconnecting of burnt/ damaged cables from panels/ junction boxes etc, cutting out the burnt out ends, making new end joints by supply and fixing new aluminium lugs/ insulation tape etc and reconnecting using new nuts/ bolts/ washer etc and restoring three phase and neutral in the junction box, complete all as specified and as directed for thecable sizefrom 150 Sqmmto 185 Sqmm 3.5 core of underground LT armoured cables.Note :- Earth work required for extending the incoming/ outgoing cable in junction box/ panel board etc shall deemed to be included in the unit rate quoted. 491 Supply, installation,commissioning and testing of factory assembled ,floor mounted ,free standing type tested LT Feeder pillar panels,with canopy ,as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycrabonate,should be weather vermin proof, anti -acid,anti-corrossive,UV resistance in accordance with IEC 61439-1,fire retardant and self extingushing in accordance with IEC 60695-2-11 ,UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accordance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties ,RoHS compliants & Halogen free. The manufacturer of boards/panels shall submit a copy oftype test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tight to base with thermoplastic screw having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosuser should be above 200mm for air circulation & to minimize temp rise. Panel shallbe fitted with one No. ofpolycarbonate IP 65 9 W LED transperent bulk head luminaire 6500K,PF >0.95 under canopy for easy maintenance . Panel should be fitted outside with one No. of 16 Amp 3 Pole IP65 industrial socket and 01 No. of 32 Amp 5P IP 65 industrial socket. 3 Phase and neutral 300 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20mm graded stone aggregate for bedding upto a height of 45 CM above ground level ,including dismanting and taking out old U/s LT panel board and reconnecting existing LT UG Cable with new panel board, complete all as specified and directed :- 492 (a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 200 Amp, 36 KA- 01 No (Incomer).(b) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 100 Amp, 10 KA- 01 No.(c) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 63 Amp, 25 KA- 01 No.(d) Multifunction Meter (V,I,PF) with suitable capacity of CTs- 01 No.(e) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set.(f) Space for spare feeder - 01 No. Note :-(i) The Contractor shall submit the drawing for approval of GE before executing the work.(ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S.(iv) MCCB should be ICu =100% ICs.(v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS). 493 Supply, installation,commissioning and testing of factory assembled ,floor mounted ,free standing type tested LT Feeder pillar panels,with canopy ,as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycrabonate,should be weather vermin proof, anti -acid,anti-corrossive,UV resistance in accordance with IEC 61439-1,fire retardant and self extingushing in accordance with IEC 60695-2-11 ,UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accordance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties ,RoHS compliants & Halogen free. The manufacturer of boards/panels shall submit a copy oftype test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tight to base with thermoplastic screw having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosuser should be above 200mm for air circulation & to minimize temp rise. Panel shallbe fitted with one No. ofpolycarbonate IP 65 9 W LED transperent bulk head luminaire 6500K,PF >0.95 under canopy for easy maintenance . Panel should be fitted outside with one No. of 16 Amp 3 Pole IP65 industrial socket and 01 No. of 32 Amp 5P IP 65 industrial socket. 3 Phase and neutral 600 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20mm graded stone aggregate for bedding upto a height of 45 CM above ground level ,including dismanting and taking out old U/s LT panel board and reconnecting existing LT UG Cable with new panel board, complete all as specified and directed :- 494 (a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 400 Amps, 36 KA- 01 No (Incomer).(b) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 200 Amps, 25 KA- 03 Nos.(c) MCCB with thermal magnetic release 4 Pole ,415 V of capacity 100 Amps, 10 KA- 02 Nos.(d) Multifunction Meter (V,I,PF) with suitable capacity of CTs- 01 No.(e) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set.(f) Space for spare feeder - 01 No. Note :-(i) The Contractor shall submit the drawing for approval of GE before executing the work.(ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S.(iv) MCCB should be ICu =100% ICs.(v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS). 495 Material andlabour forTesting of earth resistancevalue from earthing pit test terminal pointand write in/ on existingidentification board complete all as specified and as directed.Around upto 1.50 Metre Area of existing Earth Pit with tightening of Strip comprising of the following process :- 496 The following items are deemed to be inclusive of quoted rate :-(i)The above job shall be carried out by a trained technician having ITI in electrical and well known regarding earthing test. Documantary proof of the education of tradesman shall be produced by the contractor to the Engr-in-charge, before commencement of work. 497 (ii)The aforsesaid test shall be carried out in presence of user and MES represnetative. 498 (iii) Two Party (consisting 2 x 1 No. Technician with 1 No. Helper) shallreport every Morningat 9 AM to JE E/M for Daily earth testing. 499 (iv) Earth Resistance Tester will be provided by the Contractor. (Tester should be caliberated from Authorised Company/ Lab). 500 (v) Contractor shall be responsible for pouring of water in the Earth Pits Weekly at their own arrangement with Water Tanker, etc. (water will be provided by the contractor at his own arrangement and nothing extra will be admissible). 501 (vi) Contractor shall be responsible for marking of Earth check date and due date on existing Plate with synthetic enamel paint as specified by Engineer-in-Charge. 502 (vii)Contractor shall be responsible for cleaning of bushes and grass all around upto 1.50 Metre Area of existing Earth Pit with tightening of Strip. 503 Supply only charcoal dust/Breeze in trenches to improve the ER value of existing earth pits, complete all as specified and as directed. 504 Supply only common salt commercial in trenches to improve the ER value of existing earth pits, complete all as specified and as directed. 505 Material and labour for magnesium sulphate (MgSO4) for improvement of earthing resistivity, complete all as specified and directed. 506 Material and labour for Powder Earthing Backfill Compound, Grade Standard for improvement of earthing resistivity and to increase the absorption of moisture around the earthing electrode, complete all as specified and directed. 507 Supply and fixing in repair 20 mm bore galvanised steel water tubing medium grade with all fitting fixed to wall and ceiling or laid in floors etc, complete all as specified and directed. 508 Supply and fixing in repair 40 mm bore galvanised steel water tubing medium grade with all fitting laid in trenches/or laid in floor etc, complete all as specified and directed . 509 Supply and Fix in repairs Bib Tap of 15 mm dia standard of PTMT any colour high pressure screwed for iron pipe(Minimum weight 90 gms ), complete all as specifed and directed. 510 Taking downn unsv funnel of any type and size Supply and fixing in repair GI funnels for earthing, complete all as specified and as directed. 511 Taking down existing GI earthstrip 25x3mm thick as earthing lead with its accessories and re fixing to wall/roofs etc. drawn in conduit/GI pipe etccomplete all as specified and as directed.Note:- Unit rate is deemed to be included for old broken insulators/ clamps to replace with new insulators of existing size as per site and making good disturbed surfaces of floors/walls/ceiling etc complete all as directed. 512 Supply and fixing in replacement of aluminium strip 25x3mm fixed with epoxy based insulator for down conductor air terminal network including drilling two Nos holes at each joint, one set of lead washers between strips, two sets GI nut andbolt, gutties, screws etc,.on wall /roof including necessary fixing arrangement up to height 20mtrcomplete all as specified and directed.Note:- Unit rate is deemed to be included for old broken insulators/ clamps to replace with new insulators of existing size as per site and making good disturbed surfaces of floors/walls/ceiling etc complete all as directed.(ii) All safety measures shall be the responsibility of the contractor 513 Taking down of serviceable aluminium strip 25x3mm and refixing the same with epoxy based insulator/post insulator/spacerfor down/ lightening conductor air terminal network including drilling two Nos holes at each joint, one set of lead washers between strips, two sets GI nut andbolt, gutties, screws etc.on wall /roof including necessary fixing arrangement up to height 20mtrcomplete all as specified and directed.Note:- Unit rate is deemed to be included for old broken insulators/ clamps to replace with new insulators of existing size as per site and making good disturbed surfaces of floors/walls/ceiling etc complete all as directed.(ii) All safety measures shall be the responsibility of the contractor 514 Supply and fixing in repair test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos. 8mm dia 25mm long hexagonal. head screw, complete all as specified and directed. 515 Material and labourin repairs Galvanised iron Earth strip of size 32 x 6 mm fixed on proper post insulator at the instrument end complete all as per specified and as directed. 516 Repairing and maintenance of old existing earth pit by taking out carefully earth plate, watering pipe, earth lead protection pipe and re-buried the same after removing sludge from the plate & pipes including re-connection/brazing the plate and strip, wherever is required at site (Earth pit not less than 2.25 mtr deep below normal ground level ) with top edge of earth plate not less than 1.5 metres below normal ground level,complete all as specified and directed includingPCC 1:3:6 type C1 using 20mm graded stone aggregate for pit with cover of RCC 1:2:4 type B1 using 20mm graded aggregate, reinforced with welded steel wire fabric not less than 4 kg per Sqmtr with handle and angle iron frame,watering arrangment with 20 mm bore GI medium grade pipe ISI marked, GI funnel with GI mesh,filling with mixture of common salt and charcoal,necessary excavation, refilling, removing away soil and earth work in any type of soil including test point, testing and commissioning, complete all as specifed and as directed.Note : GI Funnel, brazing, mixture of salt/char coal/MgSO4 shall be measured and paid separately under releavant items. 517 S&F in repair copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc including taking down existing old unserviceable copper strip etc, complete all as specified anddirected. Note : - All Joints should be joined by Exothermic Welding or Brazing. 518 Material and labour for Brazing of copper/Aluminium for continuity, complete all as specified and as directed. 519 Supply and fix in repair of wall mounted fans PVC body 230 Voltssingle phase oscillating 400mm sweep suitable for wall mounting all as specified and directed. Make : Havells/Bajaj/ Orient.Note:-(a)Old Unserviceable ceiling fan shall be deposited to MES store yard. 520 Material and labour for fixing earth indicators made out of 3 mm thick MS sheet of size 200mm x 300mm duly fixed in MS angle iron 25mmx25mmx3mm of 450 mm long to be fixed to ground by means withnecessarycement concrete andpainting with two coats of synthetic enamel paint over a coat of red oxide primer, writing earth reading and connected items like painting of panel etc, and necessary excavation and earth work including taking down old, complete all as specified and as directed. 521 Supply, installation, testing & commissioning of maintenance free chemicalearthing system comprising of 17mm dia copper bondedrod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducingliquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 A by any NABL accredited lab. The above mentioned rod shall be installed in 4-6 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation including taking down existing one, complete all as specified and directed..Make : Model HTSP 317 of safeTrode or equivalent in Snaga/ Cubes 6 Global 522 The quoted rate shall also deemed to be included the following :- (i)Prior toinstallation of maintenance free chemicalearthing, soil resistivity test to be carried out at the location where earthingwork to be donein presence of Engr-in- Charge/JE (E/M),user and the report has tosubmitto Garrison Engineer with recommendation of manufacturer, if required additional interconnection ofearthing (not more than 08 number of earthing) to achive earth result less then 1 Ohms. The arrangement done for soil resistivity testingandsubmission of report with recommendationdeemed to be included in the quoted rate. 523 (ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors. 524 (iii) Rateofearth energizer compound of 25 Kg of 02 bags and earthresistance reducingliquid 10 litre per cane for each pit deemed to be included in the quoted rate. 525 (iv)Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor along with the sample approval 526 (v) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH value should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete. 527 (vi) Copper strip of size 20 x 3 mm shallbe fixed on proper post insulator at the instrument end (copper strip upto 7.5 RM shall be considered in unit quoted rate and extra will be measured and paid separately). 528 (vii)Testing of earth shall be carriedout in presence ofdepartmental and user representativeand report shall be submitted to Garrison Engineer duly signed by all concerned. 529 (viii)Earth resistance tester will be provided by the contractor.Tester should be calibrated from authorised company/ lab. 530 (ix)Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintained duly signed by all concerned.After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained. 531 (x) The contractor shall give a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion. 532 (xi) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including soft/ disintegrated or hard rock. 533 (xii) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is maintained. 534 (xiii) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing for each earthing shall be retained from payment due to the contractor from final bill for the guarantee period. 535 (xiv) The electrode shallcarry manufacturers name . 536 (xv) The connection clamp shall be permanentlly welded to the copper boundedrodto avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination. 537 (xvi) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm. 538 (xvii)Earth work such as auguring andmaking good the surrounding area shall carried out in any type of soil. 539 (xviii)The contractor shall submit CPRI India certified document for copper bounded rod to ensure genuineness of material. 540 (xix) Sign boardof mild steel sheet 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxideZinc chrome primer showing result of earthing shall be fixed near the earth pit after completion as directed by engr -in- charge. 541 Material and labour for Earth pit cover madeof heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 7.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mm for each electrode pit complete including taking down old one complete all as specified and directed.Make : Model SEPC 250 of SAFE TRODE or equivalent in Snaga/ Cubes 6 Global 542 Supply, installation, commissioning and testing of factory assembled, floor mounted, free standing type tested LT Feeder pillar panel, with canopy, as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accordance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS compliants & Halogen free. The manufacturer of boards/panels shall submit a copy oftype test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be minimum 200mm for air circulation & to minimize temp rise. Panel should be fitted with one No.polycarbonate IP 65, 9 W LED translucent bulk head luminaire color lamp not less than 6500K, PF >0.95 under canopy for easy maintenance. Panel shall be fitted outside with one No of 16 Amp 3 Pole IP65 industrial socket and 01 No. of 32Amp 5P IP 65 industrial socket. 3 Phase and neutral 630 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20mm graded aggregate forbedding upto a height of 45 CM above ground level, including dismanting and taking out old U/s LT panel board and reconnecting existing LT UG Cable with new panel board amplete all as specified and all as directed and comprising of the following:- 543 (a) ON load change over switch 4 Pole, 415 V of capacity 400 Amp, 36 KA - 01 No . (b) MCCB with thermal magnetic release 4 Pole, 415 V of capacity400 Amp,36 KA- 02 Nos.(c) Multifunction Meter (V,I,PF) with suitable capacity of CTs- 01 No(d) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set. (e) Space for spare feeder - 01 No. Note :-(i) The Contractor shall submit the drawing for approval of GE before executing the work.(ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S.(vi) MCCB should be ICu =100% ICs.(v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS). 544 Supply, installation, commissioning and testing of factory assembled, floor mounted, free standing type tested LT Feeder pillar panels, with canopy, as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accordance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS compliant & Halogen free. The manufacturer of boards/panels shall submit a copy oftype test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thremoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be minimum 200mm for air circulation & to minimize temp rise. Panel should be fitted with one No.polycarbonate IP 65, 9 W LED translucent bulk head luminaire color temp not less than 6500K, PF >0.95 under canopy for easy maintenance. Panel should be fitted outside with one No. of 16 A 3 Pole IP65 industrial socket and 01 No. of 32A 5P IP 65 industrial socket. 3 Phase and neutral 600 Amp current carrying capacity of Aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20 mm graded crushed stone aggregate for bedding upto a height of 45 CM above ground level, including dismanting and taking out U/s LT panel board and reconnecting existing LT UG Cable with new panel board all as directed :- 545 (a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 400 Amps36 KA- 01 No.(Incomer).(b) Change over switch 400A, 4P front operated - 01 No.(c) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 160 Amps25 KA- 02 Nos (O/G).(d) MCCB with thermal magnetic release 4 Pole, 415 V of capacity125 Amps 25 KA- 02 Nos (O/G).(e) MCCB with thermal magnetic release 4 Pole, 415 V of capacity100 Amps 10 KA- 01 No (O/G)(f) MCCB with thermal magnetic release 4 Pole, 415 V of capacity63 Amps 10 KA- 01 No (O/G)(g) MCB SPNof 240 V of capacity 40 Amps 10 KA- 01 No.(h) Multifunction Meter (V,I,PF) with suitable capacity of CTs- 01 No.(j) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set.(k) Space for spare feeder - 01 No. Note :-(i) The Contractor shall submit the drawing for approval of GE before executing the work.(ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S.(iv) MCCB should be ICu =100% ICs.(v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS). 546 Note :- An amount of Rs 2,49,138.00 on account of credit schedule for schedule A part II shall be deducted from the total amount of BOQ to arrive at the contract sum.
Contract Date : 16 Oct, 2025   |   Contract Value : 1.43 Crore
Disclaimer

We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.

Tender Detail
Website https://etender.cpwd.gov.in/login.html
Quantity
MSME Exemption No
Tender Type Open Tender
Startup Exemption Click Here
Competitive Bidding NCB
Similar Tenders