Tender Summary / Eligibility Criteria
Providing 1 No. Additional 250Kva Transformer And Ht Panel Along With Augmentation Of Lt Distribution At Cr Building Guntur
Documents
Download All
No Boq
No Corrigendum
Probable Bidders
AI engine predicts probable bidders to help you bid strategically.
MSME Exception
Technical
Tender involves procurement of high capacity electrical equipment including diaphragm coupling of pump &
motor with 90kW capacity at 2900 RPM. The project scope includes installation, testing, commissioning and
operational handover.
Previous / Similar Result
BRR : 9228991
Imp. Estimatefor replacement of1No.corroded structure 9.14mtr RCC pole along with AB swich materialsby new 9mtr PSC Pole at Kovankadu SS VIII, 250KVA/11KV Distn. Transformer in 11KV Kovankadu feeder of110/11KVManjalneerkayal SS in PalayakayalSection.. .Name of the work:2.Imp. Estimatefor replacement of1No. corroded structure 9.14mtr RCC pole along with AB swich materialsby new9mtr PSC Pole at Kovankadu SS V, 100KVA/11KV Distn.Transformer in 11KV Kovankadu feeder of110/11KV Manjalneerkayal SS in PalayakayalSection..Name of the work:3.Imp. Estimatefor replacement of1No. corroded structure 9.14mtr RCC pole along with AB swich materials by new 9mtr PSC Pole at Kovankadu SS XXVIII,100KVA/11KV Distn.Transformer in 11KV Kovankadu feederof 110/11KV Manjalneerkayal SS in PalayakayalSection. Name of the work:4. Imp. Estimatefor replacement of1No. corroded structure 9.14mtr RCC pole along with AB swich materials by new 9mtr PSC Pole at Kovankadu SS XI, 100KVA/11KV Distn.Transformer in 11KV Kovankadu feeder of110/11KVManjalneerkayal SS in PalayakayalSectionName of the work:5. Imp. Estimatefor replacement of1No. corroded structure 9.14mtr RCC pole along with AB swich materialsby new 9mtr PSC Pole at Kovankadu SS XII, 100KVA/11KV Distn.Transformer in 11KV Kovankadu feeder of110/11KV Manjalneerkayal SS in Palayakayal sectionName of the work:6. Imp-estimate is prepared to bifurcation of load at Existing Kovankadu SS-16/100KVA /11KV distribution transformer area by providing additional 100KVA/11KVTransformerinpalayakayal section
BRR : 10293125
Design, Site Preparation, Supply, Installation, Testing, Commissioning, And Amc Services Of Basic Infrastructure For The Establishment Of A Data Center At Centre For Computational And Data Sciences (Ccds), Iit Kharagpur , A. Particulars(Supply) (Price Per Unit In Rs. To Be Entered In The Sl No. 5 And Gst Amount (Per Unit) To Be Entered In Rs. In Sl No. 6) , Civil Works For All Partitions, Fire Rated Glass Works, Doors, False Floor, Road Cutting And Making Good, Building Front Tile Removing Excavation And Filling Up Any Support System, External Wall, Wire Mesh Boundary, Paver Blocks, Wall Breaking And Finishing, External Panel Room. , False Flooring Works (Dc & Electrical Room), Steps & Ramps, Civil And Gypsum Partition, Glass Wall Partitions, Fire Doors, Ante Room, Battery Room Civil Works (Breaking And Finishing Walls), Painting, Finishing, Signages, Branding Works. Grilles/ Tiles Etc. As Required. , Adiabatic Dry Cooler System Along With Pump, Tank, Piping, Controls Panel, Vfd, Pid Controller, Instrumentation As Per P & Id, Adiabatic Tank Etc., Make Up Water , Air Cooled Chiller Plant With Control Panel, Chiller Plant Manager, Auto Restart Feature For Chillers On Restoration Of Power/ Failure Mode, Associated Sensors, Controllers Control Cablings Etc. Pumps, Vfds, Piping Buffer Tanks, Pressurization System, Chemical Dozing System , Chilled Water Pahu With Control Panel, Auto Changeovers, Auto Restart Feature , Chilled Water Rdhx For Data Center Area Along With Flexible Pipes & Controls , Self-Contained Floor Mounted Refrigeration Dehumidifier Derated For 22Oc Operations With Associated Sensors, Controllers Etc. , Ups System With Isolation Transformers For 500Kva And With Incoming And Outgoing Panels As Per Sld. , Ups System With In Built Isolation Transformers For 50Kva With Outgoing Panels As Per Sld. , Li Ion Battery Pack With 10 Minutes Back Up At End Of Life For 500Kva It Loads With 5 Years Warranty , Smf Vrla Battery For Non-It Loads With 15 Minute Back Up , Modification Of Existing Electrical Panels, And Sitc Of Panels And Rest Of Electrical Works As Per Sld. 2 Incoming Panels, 4 Outgoing Panels And Additional Non It Distribution Panel As Required. , End Feed Systems, Bus Ways, Hot Swappable Tap Off Boxes/ Plug In Boxes With 3 X 32A & 1 X16a Iec 60309 Female Receptacles In Each Of 9 Tap Off (2 Spare) Boxes. (Alternative Design May Be Considered To Suit Site/ Bus Ways), 5 Tap Off Boxes (1 Spare) Each With 2 X 40A Plug Ins With Isolators. , Electrical Work As Lighting System Emergency And External Raw Power Lighting, Pump & Dry Cooler Panel Along With Cabling Etc. Earthing Systems With Earth Pits Cable Trays/ Racks/ Etc. Smoke Exhaust System. , I Bms System With Sensors, Cabling, Racks, Computers, Etc. , 800 X 1400Mm/ 1300Mm Racks With Intelligent Pdus With Leveling Etc. Suitable Of 2 Source Power Connections From Top And Provision For Rdhx Installation, Including 2 Sets Of Power Cabling With Connectors To Connect From Tap Off Boxes To Pdu. , Diesel Generator Sets With Day Tanks And Self Standing & Supported Chimneys, Earthing, Fuel Management System, Cabling, Synchronizing Panel, Battery With Chargers, Self Starting, Ats Panel, Fuel Flow Meters And Run Hours With Bms Compatibility For Data Logging. , 2 Years Warrantee For Performance And Workmanship Along With Consumables. , O&M: Deployment Of Onsite Bms, Mep Operators And Supervisor As Per Annexure-K , B. Particulars (Installation) (Price Per Unit In Rs. To Be Entered In The Sl No. 5 And Gst Amount (Per Unit) To Be Entered In Rs. In Sl No. 6) , Civil Works For All Partitions, Fire Rated Glass Works, Doors, False Floor, Road Cutting And Making Good, Building Front Tile Removing Excavation And Filling Up Any Support System, External Wall, Wire Mesh Boundary, Paver Blocks, Wall Breaking And Finishing, External Panel Room. , False Flooring Works (Dc & Electrical Room), Steps & Ramps, Civil And Gypsum Partition, Glass Wall Partitions, Fire Doors, Ante Room, Battery Room Civil Works (Breaking And Finishing Walls), Painting, Finishing, Signages, Branding Works. Grilles/ Tiles Etc. As Required. , Adiabatic Dry Cooler System Along With Pump, Tank, Piping, Controls Panel, Vfd, Pid Controller, Instrumentation As Per P & Id, Adiabatic Tank Etc., Make Up Water , Air Cooled Chiller Plant With Control Panel, Chiller Plant Manager, Auto Restart Feature For Chillers On Restoration Of Power/ Failure Mode, Associated Sensors, Controllers Control Cablings Etc. Pumps, Vfds, Piping Buffer Tanks, Pressurization System, Chemical Dozing System , Chilled Water Pahu With Control Panel, Auto Changeovers, Auto Restart Feature , Chilled Water Rdhx For Data Center Area Along With Flexible Pipes & Controls , Self-Contained Floor Mounted Refrigeration Dehumidifier Derated For 22Oc Operations With Associated Sensors, Controllers Etc. , Ups System With Isolation Transformers For 500Kva And With Incoming And Outgoing Panels As Per Sld. , Ups System With In Built Isolation Transformers For 50Kva With Outgoing Panels As Per Sld. , Li Ion Battery Pack With 10 Minutes Back Up At End Of Life For 500Kva It Loads With 5 Years Warranty , Smf Vrla Battery For Non-It Loads With 15 Minute Back Up , Modification Of Existing Electrical Panels, And Sitc Of Panels And Rest Of Electrical Works As Per Sld. 2 Incoming Panels, 4 Outgoing Panels And Additional Non It Distribution Panel As Required. , End Feed Systems, Bus Ways, Hot Swappable Tap Off Boxes/ Plug In Boxes With 3 X 32A & 1 X16a Iec 60309 Female Receptacles In Each Of 9 Tap Off (2 Spare) Boxes. (Alternative Design May Be Considered To Suit Site/ Bus Ways), 5 Tap Off Boxes (1 Spare) Each With 2 X 40A Plug Ins With Isolators. , Electrical Work As Lighting System Emergency And External Raw Power Lighting, Pump & Dry Cooler Panel Along With Cabling Etc. Earthing Systems With Earth Pits Cable Trays/ Racks/ Etc. Smoke Exhaust System. , I Bms System With Sensors, Cabling, Racks, Computers, Etc. , 800 X 1400Mm/ 1300Mm Racks With Intelligent Pdus With Leveling Etc. Suitable Of 2 Source Power Connections From Top And Provision For Rdhx Installation, Including 2 Sets Of Power Cabling With Connectors To Connect From Tap Off Boxes To Pdu. , Diesel Generator Sets With Day Tanks And Self Standing & Supported Chimneys, Earthing, Fuel Management System, Cabling, Synchronizing Panel, Battery With Chargers, Self Starting, Ats Panel, Fuel Flow Meters And Run Hours With Bms Compatibility For Data Logging. , 2 Years Warrantee For Performance And Workmanship Along With Consumables. , O&M: Deployment Of Onsite Bms, Mep Operators And Supervisor As Per Annexure-K , C. Additional Items (Price Per Unit In Rs. To Be Entered In The Sl No. 5 And Gst Amount (Per Unit) To Be Entered In Rs. In Sl No. 6. These Items Will Also Be Considered For Computing L1) , Comprehensive Annual Maintenance Contract -Year-3 , Comprehensive Annual Maintenance Contract -Year-4 , Comprehensive Annual Maintenance Contract -Year-5 , Operation And Maintenance –Year-3 , Operation And Maintenance –Year-4 , Operation And Maintenance –Year-5
BRR : 1518389
Tender For Supply Of Equipment / Material, Design, Erection, Testing, Commissioning, For Providing Sop To Paragliding Centre At Bir Uesd Baijanth-11 / 0.4Kv 250Kva Sub Station 2 1 Distribution Transformer ( Ordinary ) , 11 / 0.4 Kv, 250Kva 3 Steel Tubular Poles ( 9 M, Working Load > 200 Kgf / M² ) 4 3 Muffs With Concerete Filling 5 X-Arm: [ Channel Iron ( 100X50x5 Mm ) , Length : 2800 Mm X 4 Nos ] 6 X-Arm: [ Channel Iron ( 75X40x5 Mm ) , Length : 2800 Mm X 4 Nos ] For Supporting Do Fuse Unit & Go Switch+ 2 No. For Dist Panel Box ) 7 Ms Angle Iron ( 50X50x5 Mm ) , Length: 2800 Mm X ( 1 Nos For LaS 8 X-Arm ( Channel Iron 100X50x6mm ) 2800Mmx2no. For Transformer Bed 9 X-Arm ( Channel Iron 100X50x6mm ) 460Mmx2no. For Suprting Main Channel Of Transformer 10 M.S Angle Iron ( 50X50x6mm ) 2800Mmx2no. 11 M.S Angle Iron ( 35X35x5mm ) 460Mmx2no. 12 M.S Angle Iron ( 50X50x6mm ) 950Mmx2no. For Bed Knee Bracing 13 M.S Angle Iron ( 50X50x6mm ) Length 2800Mmx2no. 14 M.S Angle Iron ( 50X50x6mm ) 460Mmx1no. 15 Go Switchhandel Supporting Channel Iron ( 75X40x5mm ) Length 460Mm 16 Go Ab Switch Unit ( 11Kv, 400A, 25Ka ) Od Type 17 Do Fuse Unit 18 Surge Arrester 9Kv Station Class ( Porcelain Type ) 19 Discs Insulator Sets ( Comprising 1 No. Disc: ^^ ( Porcelain, Bs, 12 Kv, 90 Kn ) Including Dead End Clamps Etc. ) 20 Stay Set Complete Provide By Hpsebl 21 Stay Wire ( 7 / 3.15 Mm ) ( 6.0 Kg Per Stay Set ) Provide By Hpsebl 22 Pipe Earthing Set 23 Lt Distribution Panel Box With Acb ( 400A, 25 Ka, 4P ) , 1No. With Sfu 24 Half Clamp ( M.S. Flat 50X6 Mm ) 25 Full Clamp ( M.S. Flat 50X6 Mm ) 26 Nuts And Bolts Of Various Sizes ( Galvanised / Coated ) [ Preferably 16 Mm F Or More ( With Flat And Spring Washers ) ] 27 Aluminium Thimble 28 Aluminium Thimble 29 Lead-Tin Solder ( 60:40 ) 30 Solder Flux 31 Danger Plate 32 Barbed Wire 33 Lt Cable ( 3.5 Core 400 Mm2 ) Provide By Hpsebl 34 Lt Cable ( 3.5 Core 300 Mm2 Armoured Cable ) 35 Lt Cable Abc 3X120+16+70Mm² 36 Energy Meter ( 3-Phase, 4-Wire ) Dlms Compliant 400 A Ct Type Provide By Hpsebl 37 Ct-Pt Unit For 250Kva Dtrprovide By Hpsebl 38 Energy Meter Ht 39 Aluminium Paint. 40 Lt Switched Capacitors 9- Kva 41 Prov. Plinth & Fencing ( Civil Work ) As Per Hpsebl Standard 42 Erection Charges Complete In All Respect 43 11Kv Ht Line 44 Aaac 7 / 3.15 ( 50Mm² ) { Includes 3 Conductor Lengths For 3F And Additional 1% ( Sag, Jumpering And Wastage } 45 Steel Tubular Poles 9Mtr Long 46 3 Muffs With Concerete Filling 47 Cross Arm: [ Channel Iron ( 100X50x5 Mm ) , Length ( 2340 ) Mm X 8 Structure 48 Dead End Structures: ( Adopt Three ( 3 ) No. Per Km ) On Double Pole ( Prefer Along Road Side ) 49 X-Bracing Set - Ms Angle Iron: 50X50x5, Length [ 2125 Mm X 2 No. ] 50 Discs Insulator Sets On Dead End Structures ( Comprising 1 No.Disc: ^^ ( Porcelain, Bs, 12 Kv, 90 Kn ) Including Dead End Clamps Etc. ) X ( 3 No. Conductors ) X ( 2 No. Sides ) 51 11 Kv Pin Insulators ( Porcelain, 12 Kv, 10 Kn ) : 3 No Per Doublepole Structure Provide By Hpsebl 52 D.O Fuse Unit 53 Ht Stay / Guy Arrangement 54 Stay Set Complete In All Respect ( 1No. / Single Pole , 4 No. / Double Pole Structures ) Provide By Hpsebl 55 Stay Wire ( 7 / 3.15 Mm ) Provide By Hpsebl 56 Earthing Set Ht Complete 57 Single Continous Earth Wire ( Gi, 8 Swg ) { Alongwith 1 Wire Lengths For Avg. One Road Crossing @ 20 M And Additional 1% ( Sag And Wastage ) } @ 0.102 Kg / M 58 Eye Hook For Earth Wire 59 Earth Wire Clamp 60 Danger Plate ( 250X200x1.6 Mm ) Provide By Hpsebl 61 Nuts And Bolts Of Various Sizes ( Galvanised / Coated ) [ Preferably 16 Mm F Or More ( With Flat And Spring Washers ) ] 62 Barbed Wire 63 Aluminium Paint 64 Go Ab Switch Unit ( 11Kv, 400A, 25 Ka ) 65 Pole Clamps ( M.S. Flat50x8 Mm ) 66 Fixing Of Jumpers 67 Erection Charges For Sagging Of Conductor 68 Erection Charges For Stay Set Complete 69 Erection Charges For St Pole 9 Mtr Long ( Single Str. ) 70 Erection Charges For St Pole 9 Mtr Long ( Double Str. ) 71 Quantities Are Mentioned Above Are Tentative And Actual Quantity Shall Be Worked Out After Check Survey To Be Carried Out By The Successful Tender And Detailed Engineering And Finalization Of Tower Location Chart.Payment Shall Be Made As Per Approved Bill Of Material / Actual Quantities Measured At Site.
BRR : 1864168
Tender For Ht / Lt / Sub Station Works In Batote Circle Under Pmdp-U-Rural Electrification Works Of Batote Circle In Jammu Province Under Pmdp ( Urban ) - 1 66 / 11 Kv, 10 Mva, 3 Phase Power Transformer, Copper Winding, On-Load Tap Changer With Ht And Lt Connectors 2 66 / 11 Kv, 6.3 Mva, 3 Phase Power Transformer, Copper Winding, On-Load Tap Changer With Ht And Lt Connectors 3 66 / 11 Kv, 8 Mva, 3 Phase Power Transformer, Copper Winding, On-Load Tap Changer With Ht And Lt Connectors 4 33 / 11 Kv, 8 Mva, 3 Phase Power Transformer, Copper Winding, On-Load Tap Changer With Ht And Lt Connectors 5 33 / 11 Kv, 10 Mva, 3 Phase Power Transformer, Copper Winding, On-Load Tap Changer With Ht And Lt Connectors 6 33 / 11 Kv, 3.15 Mva, 3 Phase Power Transformer, Copper Winding, Off-Load Tap Changer With Ht And Lt Connectors 7 33 / 11 Kv, 6.3 Mva, 3 Phase Power Transformer, Copper Winding, On-Load Tap Changer With Ht And Lt Connectors 8 66 Kv, 1250Amp, 31.5 Ka Sf6 Circuit Breaker 9 Control & Relay Panel For Protection Of 66 / 11 Kv Power Transformerwith Differential Relay ( Scada Compatible ) 10 Control & Relay Panel For Protection Of 66 / 11 Kv Power Transformer Without Differentialrelay ( Scada Compatible ) 11 Control & Relay Panel For 66 Kv Feeder Vcb ( Scada Compatible ) 12 66 Kv, Multi Ratio , Multi Core , Single Phase Current Transformer 13 66 Kv, Multi Ratio , Multi Core , Voltage Transformer 14 66 Kv Lightening Arrestors 15 66 Kv, 800 A Isolator With Earthing Blade 16 66 Kv, 800 A, Isolator Without Earthing Blade 17 66 Kv Post Insulator 18 Disc Insulators For 66 Kv Line Bay 19 33 Kv Disc Insulators Complete With Fitting 20 Control & Relay Panel For Protection Of 33 / 11 Kv Power Transformerwith Differential Relay ( Scada Compatible ) 21 Control & Relay Panel For Protection Of 33 / 11 Kv Power Transformerwithout Differential Relay ( Scada Compatible ) 22 33 Kv, 1250 Amp, 25 Ka For 3 Sec, Outdoor Vacuum Circuit Breaker 23 33 Kv, 25 Ka For 3 Sec, Voltage Transformer, 33 / 0.11 Kv 24 33 Kv, 25 Ka For 3 Sec, Single Phase Current Transformer 25 Control & Relay Panel For 33 Kv Feeder Vcb ( Scada Compatible ) 26 33 Kv, 800 A, Isolator With Earthing Blade 27 33 Kv, 800 A, Isolator Without Earthing Blade 28 30 Kv Lightening Arrestors 29 2 Core 2.5Sqmm Frls Type Cu. Control Cable, Pvc Insulated Armoured Including Lugs, Ferrules Etc. 30 4 Core2.5Sqmm Frls Type Cu. Control Cable, Pvc Insulated Armoured Including Lugs, Ferrules Etc. 31 6 Core2.5Sqmm Frls Type Cu. Control Cable, Pvc Insulated Armoured Including Lugs, Ferrules Etc. 32 12 Core2.5Sqmm Frls Type Cu. Control Cable, Pvc Insulated Armoured Including Lugs, Ferrules Etc. 33 30 V Battery Bank , 100 Ah, Of 15 No. Cells Of 2V Each, Sealed Maintaince Free Vrla Type , High Impact Polyprophelene Coplymer Conatiner , Flame Retardant 34 30V, 100 Ah, Float-Cum Booster Charger , With Full Wave Rectification For 220 V, 1 Phase , 50Hz Ac Input Supply. 35 Construction Of Rcc Foundation For Power Transformersincuding Guide Rail, Considering Original Equipment Manufacturer Recommendations Includingshuttering And By Providing Reinforcement, Cement Concreting In 1:1.5:3, Painting Etc As Per Technical Specification, Approved Drawings & Scope Of Works. 36 66 Kv / 33Kv Yard Concreting / Metalling For New Substation ) Providing, Supplying And Laying 100Mm Thick Pcc ( 1:4:8 ) Using 20Mm Nominal Coarse Aggregates And Spreading 100Mm Thick Layer Of 20Mm Single Size Uncrushed / Crushed / Broken Stone Pebbles Over The Pcc Including Construction Of Toe Wall ( Exposed Wall Plastered With Cement Mortar 1:5 ) To Hold 20Mm Single Size Uncrushed / Crushed / Broken Stone Pebbles Wherever Required In The Bays Covered Under The Present Scope As Detailed In The Gelo As Per Technical Specification, Approved Drawing & Scope Of Works. & Instructions Of Engineer-In Charge. 37 66 Kv / 33Kv Yard Concreting / Metalling For Addl Transformer Substation ) Providing, Supplying And Laying 100Mm Thick Pcc ( 1:4:8 ) Using 20Mm Nominal Coarse Aggregates And Spreading 100Mm Thick Layer Of 20Mm Single Size Uncrushed / Crushed / Broken Stone Pebbles Over The Pcc Including Construction Of Toe Wall ( Exposed Wall Plastered With Cement Mortar 1:5 ) To Hold 20Mm Single Size Uncrushed / Crushed / Broken Stone Pebbles Wherever Required In The Bays Covered Under The Present Scope As Detailed In The Gelo As Per Technical Specification, Approved Drawing & Scope Of Works. & Instructions Of Engineer-In Charge. 38 Construction Of Rcc Foundation For Outdoor Mounted 66 Kv Gantry Structures & Other Equipments Considering Original Equipment Manufacturer Recommendations Including Excavation Of Pit, Shuttering And By Providing Reinforcement, Cement Concreting, Painting Etc As Per Technical Specification, Approved Drawings & Scope Of Works. Works Also Includes Providing Working Platform For Operation Of Breakers And Painting. 39 Construction Of Rcc Foundation For 33 Kv Gantry Structures & Other Equipments Considering Original Equipment Manufacturer Recommendations Including Excavation Of Pit, Shuttering And By Providing Reinforcement, Cement Concreting, Painting Etc As Per Technical Specification, Approved Drawings & Scope Of Works. Works Also Includes Providing Working Platform For Operation Of Breakers And Painting. 40 Construction Of Rcc Foundation For 33Kv Gantry Structures & Other Equipments Considering Original Equipment Manufacturer Recommendations Including Excavation Of Pit, Shuttering And By Providing Reinforcement, Cement Concreting, Painting Etc As Per Technical Specification, Approved Drawings & Scope Of Works. Works Also Includes Providing Working Platform For Operation Of Breakers And Painting. ( For Additional X-Mer ) 41 Chainlink Fencing Of 66 Kv / 33Kv Yard Of Substation By Way Of Mass Concrete In Foundationsandchainlink Fencing Of 6 Ft Height ( For New 66 / 11 Kv Or 33 / 11 Kv Substation ) 42 Cable Trench For Laying Of 11 Kv Xlpe Cables, Control Cables From Switchyard To Control Room ( For New 66 / 11 Kv Or 33 / 11 Kv Substation ) ( Inner Width 820 Mm ) 43 Cable Trench For Laying Of 11 Kv Xlpe Cables, Control Cables From Switchyard To Control Room ( For New 66 / 11 Kv Or 33 / 11 Kv Substation ) ( Inner Width 750 Mm ) 44 Cable Trench For Laying Of 11 Kv Xlpe Cables, Control Cables From Switchyard To Control Room ( For New 66 / 11 Kv Or 33 / 11 Kv Substation ) ( Inner Width 500 Mm ) 45 Compound Walling Of Identified Landby Way Of Mass Concrete In Foundationsand228 Mm Brick Wall Of 2 M Height ( For New 66 / 11 Kv Or 33 / 11 Kv Substation ) With Provision Of Double Beam. 46 Design, Engineering & Construction Of Control Room Building For New 33 / 11 & 66 / 11 Kv Receiving Substation ( 13Mx8.5M C / C ) Consisting Of Rcc Slab Including Indoor Trenches, Comprising Of Battery Room, Panel Room, Store Room, Administration Room, Toilet Etc As Required Of Overall Building Sizeas Per Electrical Requirement / Approved Drawing , Single Story Including All Internal Services Like Water Supply, Sewerage System, Finishing, Plinth Protection, Including Supply Of Construction Materials, Labour, Cement, Reinforcement Steel, Frame Work, Excavation Etc, Complete In All Resect Including , Internal Wiring, Water Proofing And Roof Projections Of 600X600mm As Per Detailed Technical Specification, Approved Drawings & Scope Of Works. 47 Development Of Land By Removing Weeds, Wild Grass, Levelling And Endulation If Any, Ornamental Land Scaping And Growing Of Ornamental Trees In Unbuilt Areas And Road Sides And Development Of Roads Along With Surface Drains And Station Fgl. 48 Borewell With Submersible Pump ( At New Receiving Substation ) 49 Earthing Mat With Gi Flat 50X8 ( For New Receiving Substation ) With 50X6 Risers. 50 Design, Engineering & Construction Ofshift Quarters For Je And Sba At New 66 / 11 & 33 / 11 Kv Substation As Per Instruction Of Engineer-In-Charge Complete In All Resect As Per Detailed Technical Specification, Approved Drawings & Scope Of Works 51 Retaining Wall ( Rcc Type ) 52 Retaining Wall ( Stone Masonry Type ) 53 Soil Filling For New / Additional Substations 54 Earthing Electrode ( 3M Long 40Mm Dia Gi Pipe ) For Receiving Substation Earth Mat ( New / Addl Transformers ) 55 Yard Lighting Of The New Receiving Sub Station Using 4 No , 12 Meter Long, Gi High Mast Poles , Continuously Tapered Of Octagonal Ofcross-Section ; Including Suitable Shallow Raft Foundation Using8 Nos 250 Watt Non Integral Flood Light Luminaire With Single Piece Die Cast Aluminum Housing And Pot Optic Reflector And Toughened Glass Cover, Conforming To Ip-66 Complete With All Accessories And Suitable Control Feeder Panel. 56 Earth Mat With Gi Flat 50X8 & 50X6 Risers For Additional Power Transformer 57 Earthing Of Augmented Power Transformer 58 D.C Distribution Board With Distributional Panel ( 30V, Dc ) With 1 No. Amp Ckt. Breaker ( For Newsubstations ) 59 A.C Distribution Boardwith Distribution Panel ( 415 V, Ac ) Complete With Ckt .Breaker , Including Lamp Etc ( For New Substations ) 60 Fire Fighting Equipment ( For Newsubstations ) A ) . Dry Chemical Powder Type ( 6Kg ) Forcontrol Room -3No. B. ) Co2 Type Of 4.5 Kg Capacity For Control Room- 4No. C ) .Co2 Type Trolly Mounted Of 22.5Kg Capacity For Switch Yard 2No. 61 11 Kv, 1250 Amp, 25 Ka For 3 Sec, Vcb Switchgear Panel Board ( 1 Incomer Panel + 3 Outgoing Panel ) ( Scada Compatible ) 62 11 Kv, 1250 Amp, 25 Ka For 3 Sec, Vcb Switchgear Panel Board ( 1 Incomer Panel + 4 Outgoing Panel ) ( Scada Compatible ) 63 11 Kv, 1250 Amp, 25 Ka For 3 Sec, Vcb Switchgear Panel Board ( 1 Incomer Panel + 5 Outgoing Panel ) ( Scada Compatible ) 64 11 Kv Isolator Double Break 3 Pole , 600 A With Earth Switch 65 11 Kv L.Afor ( 66 / 11 Kv S / S, 33 / 11 Kv S / S & For Dtr Structure ) ( 10 Ka Stn Type. ) 66 100 Kva, 11 / 0.4 Kv Stn. Transformer, Aluminium Winding, With Bimetallic Terminal Connectors, Energy Efficiency Level-Ii As Per Is: 1180 ( Part-I ) : 2014 For ( New 33 / 11 Kv & 66 / 11 Kv S / S ) 67 11 Kv Xple Power Cables- 3C 120 Mm² 68 11 Kv Xple Power Cables- 3C 185 Mm² 69 11 Kv Xple Power Cables- 3C 300 Mm² 70 11 Kv Xple Power Cables- 3C 400 Mm² 71 11 Kv Xple Power Cables- Single Core 630 Sq Mm ( With One Spare Length ) 72 Indoor Type Cable Termination Kit For 11 Kv 3C 120 Mm² Xlpe Cable 73 Indoor Type Cable Termination Kit For 11 Kv 3C 185 Mm² Xlpe Cable 74 Indoor Type Cable Termination Kit For 11 Kv 3C 300 Mm² Xlpe Cable 75 Indoor Type Cable Termination Kit For 11 Kv 3C 400 Mm² Xlpe Cable 76 Indoor Type Cable Termination Kit For Single Core 630 Sq Mm Cable 77 0Utdoor Type Cable Termination Kit For 11 Kv 3C 120 Mm² Xlpe Cable 78 Outdoor Type Cable Termination Kit For 11 Kv 3C 185 Mm² Xlpe Cable 79 Outdoor Type Cable Termination Kit For 11 Kv 3C 300 Mm² Xlpe Cable 80 Outdoor Type Cable Termination Kit For 11 Kv 3C 400 Mm² Xlpe Cable 81 Outdoor Type Cable Termination Kit For Single Core 630 Sq Mm Cable 82 Disc Insulators For 33 Kv Line Bay 83 Single Tension Fittings For Panther Conductor 84 50 Mm² Lt Ab Cable ( 3X50+1X16+1X35 Mm² ) 85 70 Mm² Lt Ab Cable ( 3X70+1X16+1X50 Mm² ) 86 120 Mm² Lt Ab Cable ( 3X120+1X16+1X95 Mm² ) 87 35 Mm² Ht Ab Cable ( 3X35+1X70 Mm² ) 88 50 Mm² Ht Ab Cable ( 3X50+1X70 Mm² ) 89 70 Mm² Ht Ab Cable ( 3X70+1X95 Mm² ) 90 120 Mm² Ht Ab Cable ( 3X120+1X95 Mm² ) 91 Insulating Piercing Connetors 92 200 Sqmm Acsr Panther Conductor 93 150 Sqmm Acsrwolf Conductor 94 100 Sqmm Acsrdog Conductor 95 50 Sqmm Acsrrabbit Conductor 96 30 Sqmm Acsr Weasel Conductor 97 11 / 0.433 Kv, 630 Kva, 3-Phase Distribution Transformerswith Bimetallic Terminal Connectors Energy Level-2, ( Aluminium Wound Upto 200Kva, Copper Woundfor 250Kva Or Higher Kva Ratings ) 98 11 / 0.433 Kv, 400 Kva, 3-Phase Distribution Transformerswith Bimetallic Terminal Connectors Energy Level-2, ( Aluminium Wound Upto 200Kva, Copper Woundfor 250Kva Or Higher Kva Ratings ) 99 11 / 0.433 Kv, 250 Kva, 3-Phase Distribution Transformerswith Bimetallic Terminal Connectors Energy Level-2, ( Aluminium Wound Upto 200Kva, Copper Woundfor 250Kva Or Higher Kva Ratings ) 100 11 / 0.433 Kv, 63 Kva, 3-Phase Distribution Transformerswith Bimetallic Terminal Connectors Energy Level-2, ( Aluminium Wound Upto 200Kva, Copper Woundfor 250Kva Or Higher Kva Ratings ) 101 11 / 0.433 Kv, 100 Kva, 3-Phase Distribution Transformerswith Bimetallic Terminal Connectors Energy Level-2, ( Aluminium Wound Upto 200Kva, Copper Woundfor 250Kva Or Higher Kva Ratings ) 102 11 / 0.433 Kv, 25 Kva, 3-Phase Distribution Transformerswith Bimetallic Terminal Connectors Energy Level-2, ( Aluminium Wound Upto 200Kva, Copper Woundfor 250Kva Or Higher Kva Ratings ) 103 120 Mm² Lt4core Pvc Cable 104 400 Mm² Single Core Xlpe Cable ( 1100 V ) 105 240 Mm² Single Core Xlpe Cable ( 1100 V ) 106 185 Mm² Single Core Xlpe Cable ( 1100 V ) 107 150 Mm² Single Core Xlpe Cable ( 1100 V ) 108 120 Mm² Single Core Xlpe Cable ( 1100 V ) 109 95 Mm² Single Core Xlpe Cable ( 1100 V ) 110 70 Mm² Single Core Xlpe Cable ( 1100 V ) 111 50 Mm² Single Core Xlpe Cable ( 1100 V ) 112 25 Mm² Single Core Xlpe Cable ( 1100 V ) 113 33 Kv Pin Insulators With Pin 114 11Kv Pin Insulators With Pin 115 11Kv Go, Ab Switch 200 Amp 116 11Kv Disc Insulators Complete With Fitting 117 11 Kv Do Fuse 100 A 118 33 Kv Post Insulator 119 20 Mm Dia Stay Set Complete With Stay Wire 7 / 4 Mm, Turn Buckle, Bow, Tightner, Guy Clamps, Anchor Plates, Guy Insulators, Guy Grip, Thimbles Etc 120 16 Mm Dia Stay Set Complete With Stay Wire 7 / 3.15 Mm, Turn Buckle, Bow, Tightner, Guy Clamps, Anchor Plates, Guy Insulators, Guy Grip, Thimbles Etc. 121 Grouting Of Stay Set As Per Td / Approved Drawings 122 66 Kv Disc Insulators Complete With Fitting ( 11 Kv * 6Nos. = 01 No. ( 66 Kv ) ) 123 Suspension Fitting For Wolf Conductor ( 66 Kv Line ) 124 Earthing Of Poles & Fittings By Gi Earthing Rod 20X2500 Mm & 6 Swg Gi Wire 125 Tension Fitting For Wolf Conductor 126 8 Mtr.Long Pccpolewl-250 Kg 127 11 Mtr. Long Pcc Pole Wl- 360 Kg 128 9 Mtr. Long Pccpolewl-300 Kg 129 16 Mtr. Long Steel Tubular Polewith Welded Steel Base Plate Of Designation 410 Sp -80 ( Is 2713, Pt I, Ii, Iii 1980. ) 130 13 Mtr. Long Steel Tubular Polewith Welded Steel Base Plate Of Designation 410 Sp -69 ( Is 2713, Pt I, Ii, Iii 1980. ) 131 11 Mtr. Long Steel Tubular Polewith Welded Steel Base Plate Of Designation 410 Sp -56 ( Is 2713, Pt I, Ii, Iii 1980. ) 132 8 Mtr. Long Steel Tubular Polewith Welded Steel Base Plate Of Designation 410 Sp -15 ( Is 2713, Pt I, Ii, Iii 1980. ) 133 9 Mtr. Long Steel Tubular Polewith Welded Steel Base Plate Of Designation 410 Sp -33 ( Is 2713, Pt I, Ii, Iii 1980. ) 134 Stone Pad For Pcc Poles ( 400X400x75 ) 135 Aluminium Jointing Sleeves 136 Aluminium Paint 137 Red Oxide 138 Anti-Climbing Device With Clamps 139 Cement Concrete Foundation Of St Poles Using Cement Concreting , 1 Part Cement, 2 Part Sand, 4 Part 40 Mm Size Stone Aggregate Chips ( 1:2:4 ) As Per Approved Drawings ( Tentative 0.45 Cum / Pole ) 140 66 Kv Danger Plates With Clamps 141 33 Kv Danger Plates With Clamps 142 11Kv Danger Plates With Clamps 143 440 V Danger Plates With Clamps 144 Dlms Type Meter For Dt Metering With Modem 145 Meter Box With Resin Cast Ring Type Cts For Dt Metering 146 Earthing Lt Pole ( Gi Earthing Spike Made Of 20Mm Solid Rod Or 8 Swg Earthing Coil ) 147 Earthing Of Distribution Transformer - Pipe Earthing. 148 11 Kv Outgoing Feeders- Pipe Earthing.With Gi Strip 149 25Mm Dia Gi Rod 3 M Long For Earth Mat 150 Earth Wire ( 7 / 4.00 Sqmm ) 151 Eye Bolts For Guard Netting 152 Gi Wire 6 Swg, 8 Swg As Per Requirement For Guard Netting 153 Galvanised Steel Structures / Gi Channel X-Arm And Gi V-Cross Armincluding Clamps And Braces / Gi Channels / Angle / Flats Of Sizes. 154 Galvanized Nuts & Bolts 155 Gi Barbed Wire For Anti Climbing With Clamps ( 35 Turns / Pole ) 156 Gi Flat For Earthing 50X6 Mm ( For Earthing Risers For 33 Kv Bay ) 157 Gi Strip 25X3 Mm For Earthing Of Dtr, 158 Gi U-Clamps For Shackle Insulators 159 Lt Distribution Box With Mounting Clamps For 25 Kva Dtr With Mccbs With Suitable Incoming And Outgoing Ckts 160 Lt Distribution Box With Mounting Clamps For 63 Kva Dtr With Mccbs With Suitable Incoming And Outgoing Ckts 161 Lt Distribution Box With Mounting Clamps For 100 Kva Dtr With Mccbs With Suitable Incoming And Outgoing Ckts 162 Lt Distribution Box With Mounting Clamps For 250 Kva Dtr With Mccbs With Suitable Incoming And Outgoing Ckts 163 Lt Distribution Box With Mounting Clamps For 400 Kva Dtr With Mccbs With Suitable Incoming And Outgoing Ckts 164 Lt Distribution Box With Mounting Clamps For 630 Kva Dtr With Mccbs With Suitable Incoming And Outgoing Ckts 165 Transformer Pad ( For 400 Kva & 630 Kva Dtrs ) 166 Lt Line Spacers 167 Mccb - 200 Amps ( With Enclosure And Pole Mounting Arrangement ) For 100 Kva, 11 / 0.4 Kv Station Transformer 168 Pg Clamps For 200 Mm² Acsr Conductor 169 Pg Clamps For 150 Mm² Acsr Conductor 170 Pg Clamps For 100 Mm² Acsr Conductor 171 Pg Clamps For 30 Mm² Acsr Conductor 172 Pg Clamps For 50 Mm² Acsr Conductor 173 Pg For Lt Ab Cable 174 Shackle Insulators With Pin 175 Sundry Items Like Aluminium Lugs, Jumpers, Binding Tape, Droppers Etc. 176 Suspension / Tension Clamp With Eye Hook 177 T Clamps For Panther Conductor 178 Wedge Connectors / Pg Clamps 179 Straight Through For Lt Ab Cable Joining Kit 180 Soil Cutting 181 Approach Road To The Substation Land If Required 182 Lt 3 Phase Pole Distribution Box With Busbar Lt Service Connection 183 35 Sqmm 4C Pvc Cable 184 Safety And Operation Instrument 185 Provision For Bus- Bar & 11 Kv Supporting Structures ( For Aug Transformers ) 186 Heat Shrinkable Outdoor Cable Termination Kit 187 Mid Span Straight Throgh Jointing Kit For 11 Kv Abc 188 Acdbfor R&M33 / 11 Kv S / S 189 Dcdbfor R&M33 / 11 Kv S / S 190 New / Replacement 33Kv Vcbs For R&M33 / 11 Kv S / S 191 New 33Kv C& R Panels For R&M33 / 11 Kv S / S ( Scada Compatible ) 192 New / Replacement Of 33 Kv Lasfor R&M33 / 11 Kv S / S 193 New / Replacement Of 33 Kv Ctsfor R&M33 / 11 Kv S / S 194 New / Replacement Of 33 Kvptsfor R&M33 / 11 Kv S / S 195 New / Replacement Of 33 Kv Isolatorwith Earthing Bladefor R&M33 / 11 Kv S / S 196 New / Replacement Of 33 Kv Isolatorwithout Earthing Blade For R&M33 / 11 Kv S / S 197 11 Kv Vcb Switchgear Panel Board ( Scada Compatible ) ( 1 Incomer Panel + 4 Outgoing Panel ) For R&M 33 / 11 Kv S / S 198 Indoor Type Cable Termination Kit For 11 Kv 3C 400 Mm² Xlpe Cable For R&M 33 / 11 Kv S / S 199 Outdoor Type Cable Termination Kit For 11 Kv 3C 400 Mm² Xlpe Cable For R&M 33 / 11 Kv S / S 200 11Kvgo Switich For R&M33 / 11 Kv S / S 201 11Kv La Setsfor R&M33 / 11 Kv S / S 202 Battery Bankfor R&M33 / 11 Kv S / S 203 Battery Chargerfor R&M33 / 11 Kv S / S 204 Fire Extinguisher Systemfor R&M33 / 11 Kv S / S 205 Powercable 11Kv 400Sqmm For R&M33 / 11 Kv S / S
BRR : 1861577
Tender For Supply Of Equipment Material , Design, Erection, Testing Commissioning For Sop To Lwss Batran, Padher And Sakoh By Prov. 11 / .4 Kv 250 Kva S / Stn. At Baruila Nallah A / W 11 Kv Ht Section Kher Under Esd Rehan Edfatehpur--- 1 Supply part of 11/.4 KV 250 KVA DISTRIBUTION SUB STATION 2 11/.4 KV 250KVA DTR (REC Sep. ord 11/1976 3 Prov. ST PolePole 9 Mtr. Long W/L 200 Kgs 4 Muff for steel tubular pole with concrete filling 5 X-Arm: [Channel Iron (100x50x5 mm), Length : 2800 mm X 2 Nos] for incomer line 6 MS A.I.(50X50x6 mm), Length: 2800 mm x(1 Nos for LAs ) 7 X-Arm: [Channel Iron (75x40x5 mm), Length : 2800 mm X 4 Nos] for supporting DO fuse unit & GO switch 8 X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for transformer bed 9 X-Arm [Channel Iron (100x50x6 mm), Length : 460 mm x 2 Nos for supporting Main Channel of Transformer] 10 MS A.I.(50X50x6 mm), Length: (2800 mm) x 2 No. 11 MS Angle Iron (35X35x5 mm), Length : 460 mm x 2 Nos 12 MS A.I.(50X50x6 mm), Length: (950 mm) x 2 Nos. of bed knee bracing 13 MS Angle Iron (50X50x6 mm), Length : (2800 mm) x2 Nos for Transformer LT Distribution Box and G.O switch fixing assembly 14 MS Angle Iron (50X50x6 mm), Length : (450 mm)x1 Nos for Transformer LT Distribution Box and G.O switch fixing assembly 15 G.O. Switch handle supporting: [C.I. (75x40x6mm), length: 460mm for Transformer LT Distribution Box and G.O switch fixing assembly 16 G.O AB switch unit (11KV,400,663KA) Tripple pole O/D type 17 D.O Fuse unit 18 Surge Arrester, 9 kV Station Class 19 Discs insulator sets (comp. 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) i/c Dead End Clamps etc.) 20 Stay set complete 21 Staywire (7/3.15mm)( 10 Kg per stay set) 22 Pipe earthing with GI,Charcoal & Salt 23 Prov. LT distribution panel with MCCB (400 A, 36 KA, 4P,1 No.) & SFU (100 A 4 No. rewireble) for 250KVA Trf. as per specification 24 Half clamp (M.S. Flat 50x6) 25 Full clamps (M.S. Flat 50x6) 26 M. S. Nuts & Bolts off sizes (Galvanised coated) [prefarably 16mm Ø or more (with flat and spring washer) 27 Aluminium Thimbles 28 Copper Thimble 29 Danger Plate 30 Barbed wire (REC Sp F 3/1981) 31 LT Cable 3-1/2 core-185mm sq. 32 Alluminium Paint 33 Prov.ACSR, 6/1/3.35 mm 34 Prov. Transformer Bed plinth for 250KVA S/Stn structure complete with CC 1:6:12 R.R. massonery & plastering etc. a/w Chain link fencing, Angle iron Gate etc. for DTR Fencing. 35 Erection part of 11/.4 KV 250 KVA DISTRIBUTION SUB STATION 36 11/.4 KV 250KVA DTR (REC Sep. ord 11/1976 37 Prov. ST PolePole 9 Mtr. Long W/L 200 Kgs 38 Muff for steel tubular pole with concrete filling 39 X-Arm: [Channel Iron (100x50x5 mm), Length : 2800 mm X 2 Nos] for incomer line 40 MS A.I.(50X50x6 mm), Length: 2800 mm x(1 Nos for LAs ) 41 X-Arm: [Channel Iron (75x40x5 mm), Length : 2800 mm X 4 Nos] for supporting DO fuse unit & GO switch 42 X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for transformer bed 43 X-Arm [Channel Iron (100x50x6 mm), Length : 460 mm x 2 Nos for supporting Main Channel of Transformer] 44 MS A.I.(50X50x6 mm), Length: (2800 mm) x 2 No. 45 MS Angle Iron (35X35x5 mm), Length : 460 mm x 2 Nos 46 MS A.I.(50X50x6 mm), Length: (950 mm) x 2 Nos. of bed knee bracing 47 MS Angle Iron (50X50x6 mm), Length : (2800 mm) x2 Nos for Transformer LT Distribution Box and G.O switch fixing assembly 48 MS Angle Iron (50X50x6 mm), Length : (450 mm)x1 Nos for Transformer LT Distribution Box and G.O switch fixing assembly 49 G.O. Switch handle supporting: [C.I. (75x40x6mm), length: 460mm for Transformer LT Distribution Box and G.O switch fixing assembly 50 G.O AB switch unit (11KV,400,663KA) Tripple pole O/D type 51 D.O Fuse unit 52 Surge Arrester, 9 kV Station Class 53 Discs insulator sets (comp. 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) i/c Dead End Clamps etc.) 54 Stay set complete 55 Staywire (7/3.15mm)( 10 Kg per stay set) 56 Pipe earthing with GI,Charcoal & Salt 57 Prov. LT distribution panel with MCCB (400 A, 36 KA, 4P,1 No.) & SFU (100 A 4 No. rewireble) for 250KVA Trf. as per specification 58 Half clamp (M.S. Flat 50x6) 59 Full clamps (M.S. Flat 50x6) 60 M. S. Nuts & Bolts off sizes (Galvanised coated) [prefarably 16mm Ø or more (with flat and spring washer) 61 Aluminium Thimbles 62 Copper Thimble 63 Danger Plate 64 Barbed wire (REC Sp F 3/1981) 65 LT Cable 3-1/2 core-185mm sq. 66 Alluminium Paint 67 Prov.ACSR, 6/1/3.35 mm 68 Prov. Transformer Bed plinth for 250KVA S/Stn structure complete with CC 1:6:12 R.R. massonery & plastering etc. a/w Chain link fencing, Angle iron Gate etc. for DTR Fencing. 69 Supply Part of HT LINE WITH ACSR 6/1/3.35 mm sq. ON STEEL POLES (0.780KM) 70 ACSR 6/1/3.35 (55mm²) {Includes 3 conductor lengths for 3F and Additional 1% (Sag, Jumpering and wastage} 71 Prov. Steel tubular poles. 9mtrs 72 Muff for steel tubular pole (2000mm long) with concrete filling 73 Cross Arm: [Channel Iron (100x50x6 mm), Length 1270 mm (i/c tolerence of 100mm either side) x2 structure( Run Through structure (Formation Tringle) 74 Angle Iron (50x50x5 mm), Length (2x750) mm x 1 structures (Run Through structure (Formation Tringle) 75 Pole Top Bracket [MSCI:100x50x6mm-100mm] 76 11 kV Pin Insulators (Porcelain, 12 kV, 10 KN): 3 No per pole structure (Run Through structure (Formation Tringle) 77 Belt Set - MS Angle Iron: 50x50x6, Length [1800 mm x 2 No.]for Dead End Structures 78 X-Bracing Set - MS Angle Iron: 50x50x6, Length [2125 mm x2 No.] for Dead End Structures 79 X-Arm(Horizental) - MS C. Iron: 50x50x6, Length [2340 mm x2 No.]for Dead End Structures 80 Discs insulator sets on Dead End structures (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides)for Dead End Structures 81 11 kV Pin Insulators (Porcelain, 12 kV, 10 KN): 3 No per pole structure for Dead End Structures 82 Stay set complete in all respect ( Single Pole-1No. , /D. Pole Structures-4Nos.) 83 Stay Wire (7/3.15 mm) (8.0 kg Per Stay Set) 84 HT earthing set complete (REC Constr. Standared J-1) 85 Single Continous Earth wire (GI, 8 SWG) {alongwith 1 wire lengths for avg. one road crossing @ 20 m and Additional 1% (Sag and wastage)} @ 0.102 kg/m 86 Eye Hook for earth wire 87 Earth Wire Clamp 88 MS Chanel Iron 75x40x6mm, length: 2400mm for road crossing/G.O Switch 89 Half clamp (on D/P dead end str:4Nos; on Run Through Str. 2Nos.) 90 Full clamp (on D/P dead end str:4Nos; on Run Through Str. 2Nos.) 91 Danger Plate (250X200X1.6 mm) 92 M. S. Nuts & Bolts off sizes (Galvanised coated) [prefarably 16mm Ø or more (with flat and spring washer) 93 Barbed wire (REC Sp F 3/1981) 94 G.O AB switch unit (11KV,400,663KA) Tripple pole O/D type 95 Alluminium Paint 96 Erection Part of HT LINE WITH ACSR 6/1/3.35 mm sq. ON STEEL POLES (0.780 KM) 97 ACSR 6/1/3.35 (55mm²) {Includes 3 conductor lengths for 3F and Additional 1% (Sag, Jumpering and wastage} 98 Prov. Steel tubular poles. 9mtrs 99 Muff for steel tubular pole (2000mm long) with concrete filling 100 Cross Arm: [Channel Iron (100x50x6 mm), Length 1270 mm (i/c tolerence of 100mm either side) x2 structure( Run Through structure (Formation Tringle) 101 Angle Iron (50x50x5 mm), Length (2x750) mm x 1 structures (Run Through structure (Formation Tringle) 102 Pole Top Bracket [MSCI:100x50x6mm-100mm] 103 11 kV Pin Insulators (Porcelain, 12 kV, 10 KN): 3 No per pole structure (Run Through structure (Formation Tringle) 104 Belt Set - MS Angle Iron: 50x50x6, Length [1800 mm x 2 No.]for Dead End Structures 105 X-Bracing Set - MS Angle Iron: 50x50x6, Length [2125 mm x2 No.] for Dead End Structures 106 X-Arm(Horizental) - MS C. Iron: 50x50x6, Length [2340 mm x2 No.]for Dead End Structures 107 Discs insulator sets on Dead End structures (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides)for Dead End Structures 108 11 kV Pin Insulators (Porcelain, 12 kV, 10 KN): 3 No per pole structure for Dead End Structures 109 Stay set complete in all respect ( Single Pole-1No. , /D. Pole Structures-4Nos.) 110 Stay Wire (7/3.15 mm) (8.0 kg Per Stay Set) 111 HT earthing set complete (REC Constr. Standared J-1) 112 Single Continous Earth wire (GI, 8 SWG) {alongwith 1 wire lengths for avg. one road crossing @ 20 m and Additional 1% (Sag and wastage)} @ 0.102 kg/m 113 Eye Hook for earth wire 114 Earth Wire Clamp 115 MS Chanel Iron 75x40x6mm, length: 2400mm for road crossing/G.O Switch 116 Half clamp (on D/P dead end str:4Nos; on Run Through Str. 2Nos.) 117 Full clamp (on D/P dead end str:4Nos; on Run Through Str. 2Nos.) 118 Danger Plate (250X200X1.6 mm) 119 M. S. Nuts & Bolts off sizes (Galvanised coated) [prefarably 16mm Ø or more (with flat and spring washer) 120 Barbed wire (REC Sp F 3/1981) 121 G.O AB switch unit (11KV,400,663KA) Tripple pole O/D type 122 Alluminium Paint 123 Supply Part of CT/PT Unit 124 Prov. 11KV CT-PT unit i.e. PT (1 unit, 11KV/110V):CT (3No.10-400/500A) accuracy class 0.5S. 125 Prov, Energy meter (3 phase, 4 wire) HT CT type for Above 126 Pvc Multistrand 4 mm Sq. copper wire with 1 inch GI pipe fir concealing 127 X-Arm: [Channel Iron (100x50x6 mm), Length : 460 mm X 2 Nos] for supporting main channel for CT-PT unit 128 CT-PT Unit Belting and Knee Bracing 129 MS Angle Iron (50x50x5 mm), Length : 2800mmx 4 Nos. 130 MS Angle Iron (35x35x5 mm), Length : 2800mmx 2 Nos. 131 Half clamp (MS Flat 50x6 mm) 132 Full clamp (MS Flat 50x6 mm) 133 Nut & Bolts off size 134 Aluminium Thimble 135 copper Thimble 136 Erection Part of CT/PT Unit 137 Prov. 11KV CT-PT unit i.e. PT (1 unit, 11KV/110V):CT (3No.10-400/500A) accuracy class 0.5S. 138 Prov, Energy meter (3 phase, 4 wire) HT CT type for Above 139 Pvc Multistrand 4 mm Sq. copper wire with 1 inch GI pipe fir concealing 140 X-Arm: [Channel Iron (100x50x6 mm), Length : 460 mm X 2 Nos] for supporting main channel for CT-PT unit 141 CT-PT Unit Belting and Knee Bracing 142 MS Angle Iron (50x50x5 mm), Length : 2800mmx 4 Nos. 143 MS Angle Iron (35x35x5 mm), Length : 2800mmx 2 Nos. 144 Half clamp (MS Flat 50x6 mm) 145 Full clamp (MS Flat 50x6 mm) 146 Nut & Bolts off size 147 Aluminium Thimble 148 copper Thimble
Disclaimer
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tender Detail
| Website | https://etender.cpwd.gov.in/login.html |
| Quantity | 0 |
| MSME Exemption | No |
| Tender Type | Open Tender |
| Startup Exemption | Click Here |
| Competitive Bidding | NCB |
TENDER INSIGHTS
858
Electric TendersLive
Tell us about your Product / Services,
We will Find Tenders for you