TDR : 56393708
Central Public Works Department

Tender Brief :

Tirupati, Andhra Pradesh

Additional Facilities For 300 KLD WTP And 300 KLD STP, Open Stairs To Research Block Rear Side And Canteen In Research Block. SH: Renovation Work Including Canteen In 2Nd Floor Of Research Block & Open Staircase To Research Block.

Published: 09 Jul 2026
Opening: 16 Jul 2026
Closing: 16 Jul 2026
Amount: 65.10 Lakhs
EMD: 1.30 Lakhs
Tender Fee: Ref. Documents


Works Acid Storage Tank Aerobridge Aircraft Hanger Airport Development Angle
1
Days Left
Tender Summary / Eligibility Criteria
Additional Facilities For 300 KLD WTP And 300 KLD STP, Open Stairs To Research Block Rear Side And Canteen In Research Block. SH: Renovation Work Including Canteen In 2Nd Floor Of Research Block & Open Staircase To Research Block.
Documents Download All
a2d746fe-58a1-4be5-ae42-30c39605a70d
a2d746fe-58a1-4be5-ae42-30c39605a70d.html
DocumentsList
DocumentsList.zip
No Boq
No Corrigendum
Probable Bidders

AI engine predicts probable bidders to help you bid strategically.

MSME Exception
Explore More →
Technical
Tender involves procurement of high capacity electrical equipment including diaphragm coupling of pump & motor with 90kW capacity at 2900 RPM. The project scope includes installation, testing, commissioning and operational handover.
Previous / Similar Result
BRR : 10363312 Tender For Construction Of New Office Building Of Municipal Board Nawa - CIVIL WORKSClearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. 2 Earth work in excavation by mechanical means (Hydraulic Excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sum on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter.All kinds of soils 3 Add extra for foundation/trenches/drains for every additional lift of 1.5 Mtr. or part thereof inAll kinds of soil 4 Supplying and Filling in plinth with blown sand under floors including watering ramming consolidating and dressing complete including cost of sand. 5 Supplying chemical emulsionin sealed containers including delivery as specified. Chlorpyriphos/Lindane emulsifiable concentrate of 20% 6 Diluting and injection Chloropyrifos Emulsifiable concentrate 20% with 1% concentration for PRE-CONSTRUCTIONAL Anti termite treatment as per IS 6313 part III as amended from time to time and creating a continuous chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of wall and floor along the external perimeter of building expansion joints, over the top surface of consolidated earth of which aproch is to be laid surrounding of pipes and conduits etc. complete as per specification (Plinth floor area only shall be measured for payment and excluding the cost of chemical emulsion) . 7 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size). (UNDER FLOOR) 8 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). (FLOOR UNDER FOOTING AND FOUNDATIONS 9 Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M25 grade Design Mix by usingmin 410 kg of cement per Cum . 10 Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcementfor Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. M25 grade Design Mix by usingmin 410 kg of cement per Cum . 11 Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcementfor Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc. M20 grade Nominal Mix / Design Mix 12 Providing and laying in position Ready mix concrete manufactured in fullyautomatic Batching Plant andtransported to site intransit mixer for having continous agitated mixer, manufactured as per approved mix design of specified grade of RCC work including pumping of R.M.C. from transit mixer to site of laying , exculding the cost of centering, shuttering and reinforcement with all lead and lift including cost of admixtures in recommended portion as per IS 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in charge.All works upto floor V floor. Design Mix by usingM-25 grade concrete by using min 410 kg of cement per Cum 13 Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. 14 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for : Walls (any thickness) including attached pilasters,buttressesplinthandstring course. 15 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for :Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc. 16 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for :Columns, pillars, posts and struts etc. 17 Add extra for additional height in centring, shutteringwhere ever required with adequate bracing, propping etc. including cost of de-shuttering and decentring at alllevels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan are is to be measured) 18 Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level.(Original producers who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786) Thermo-mechanically Treated bars (Conforming of relevent IS code) 19 Providing and fixing stainless steel railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). Grade 304 20 Steel work in built up tubular trusses including cutting, hoisting ( height upto 10 m) fixing in position and applying a priming coat of approved steel primer, welded and bolted including special shaped washers etc. complete.Hot finished welded type tubes. 21 Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in: Cement Mortar 1:6 ( 1-Cement : 6-Sand). 22 Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in : Cement mortar 1 : 6 (1 cement : 6 coarse sand) 23 Half Brick work with mechanised autoclaved flyash lime bricks conforming to IS: 12894 :2002 of class designation 75 in superstructure above plinth level upto floor V level in. Cement mortar 1 : 6 (1 cement : 6 coarse sand) 24 Add extra providingand placing in position 2 Nos. ,6mm Ø M.S. barat every thirdcourse of half brick masonry 25 Providing and fixing Stone jali 40mm thick Red/Pink sand stone throughoutin cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali patterns to be cut square to jali slab without any chamfers etc: 26 Plaster on new surface on walls in cement sand mortar 1:4 including rackingofjointsetc. complete fine finish : 20mm thick . 27 6 mm thick cement plaster to ceiling of mix1:3 (1cement : 3-fine sand) 28 Providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth completeNew Plastered Surface (three or more coats) 29 Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding:Two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect 30 Finishing walls with textured exterior paint of required shade as per approved colour complete as per manufacturers specificationsincluding primer coat and protecting coat including scaffolding and safety provisionTrowel Finish av. thickness 1500 to 2000 microns. 31 Painting with synthetic enamel paint of approved brand and manufacture togive an even shade :Two or more coats on new work 32 Making of drip course (Tapka) in cement sand mortar 1:6 width upto 40 mmand 10 mm thick as per approved design 33 Making grooves as per design in plaster 10mm to 20mm wide. 34 P & F 1st quality Heavy Duty Vitrified Double Charged tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1: 4 including grounting the joints with white cement and matching pigment etc complete.Size 600X600mm 35 size600 mm X 1200mm 36 P & F 1st quality Heavy Duty Vitrified glazed MAT tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1: 4 including grounting the joints with white cement and matching pigment etc complete. size600 mm X 600 mm 37 Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). 38 Extraforusingsize above 200x300mm in glazed tiles and for using 400mm x 400mm MAT finishedtiles in place of 300mm x 300mm size. 39 Kota stone slab flooring 25 mm thick over 20 mm (average) thickbase laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing completewith base of cement mortar 1 : 4 (1 cement : 4 coarse sand) For area of each slab from 2001 to 5000 Sq.Cm 40 Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete For area of each slab upto 2001Sqcm 41 Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab. 42 Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles includingrubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand) Medium shade using approximately 50% white cement and 50% ordinary cement. 43 Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete.South Red1501 Cm2 to 3600 Cm2 Tiles 44 Extra for providing edge moulding to 15-18mm thick marble/ Granite/Kota stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.Granite/Kota Stone Work Full Edge moulding 45 Extra for fixing marble /granite stone over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete 46 Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete 47 Providing and fixing 1st quality standard Marble printed/ Granite Shade or Light/dark shad glazed tiles confirming to IS : 13753 & IS :15622 of size 300mm x 600mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). 48 Providing and fixing wall panelling using soft wood frame of size 50x25mm @600 mm c/c in both directions duly treated with anti-termite treatment making grooves painting of grooves specification and drawing using : ISI 9 mm teak ply one side BWR 49 Providing and fixing pressed steel door frames confirming to IS 4351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applyinga coat of approved steel primer after pre-treatment of the surface including filling with CC 1:2:4(M15 grade) complete as directed by Engineer-in-charge : Profile E 50 Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesinin glue both sides with approved steel fittings complete as per annexure A: 35 mm thick . Commercial Veneer both side 51 Extra for providing external lipping with 2ndclass teak wood battens 6 mm minimum depth on all edges of shutters (over all area of door shutter to be measured) Over item no. 8.13. 52 Providing & Fixing mica of approved make for inner/outer side of shutters with fevicol & nails completeas per approved by engineer in charge. 0.8mm thick mica 53 Providing and fixing M.S. sheet 1mm thicksingle leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint 54 Providing and fixing fully panelled /partly panelleddouble leaf shutters frame for windows and ventilators as per approved design and drawings with approved steel fittings as per Annexure ‘A’ and width of styles, bottom and top rails 75mm including intermediate rails 50mm wide, beading of 25mm x 15mm size on both faces : 35 mm thickGhana wood grade I 55 Providing and fixing bright finished Mortice lock of approved make Godrej or equivalent withpair ofCP handles for doors with necessary screws etc complete (Best make of approved quality) as per direction of Engineer-in-charge. 56 Providing and fixing of uPVC casement fixed windows or ventilators manufactured in ISO 9001:2000 & 14001:2004 certified company. Frame : Made from the Extruded uPVC Window Profile Section of size 60 x 60mm having outer wall thickness of 2.25mm (+/- 0.2mm) and 3 box multi-chamber construction, White in finish, duly reinforced with 1.2mm thick G/J/U/O TYPE GI section. All the four corners shall be mitered cut & thermal welded so as to form window frame. Frame shall be milled with drain and air equalizer hole in order to be water tight and for drainage of acCumulated water, if any, to outer side. Fix Mullion made of 76 x 60mm uPVC Profile Section with steel reinforcement shall be provided in windows as per the requirement. Frame shall have ‘O’ type EPDM gasket fitted in in-built groove of frame profile for proper air & sound insulation of the shutter. Glazing bead of size 34 x 20mm with ‘K’ & ‘O’ type inner and outer EPDM weather seal gaskets alongwith 5mm thick ISI make plain float glass.All welding joints of frame and shutter shall be cleaned and milled with the CNC mechanism to provide uniform grooved finish on all visible joints. Hardware : Installation at Site : Complete window is to be installed on site with 10 x 100mm fastners with white cap in existing pre-finished wall cut-out cemented to glass level plane at all height & width and silicon glue is applied to fill up the crevices between wall and window frame. Complete in all respect as per the drawing and specifications and direction of engineer-in-charge. (Insert 6mm tougend glass) 57 Providing and fixing of uPVC Sliding windows: Frame Made from the Extruded uPVC Window Profile Section of size 106w x 50h mm having outer wall thickness of 2.5mm (+/- 0.2mm) and 3 box multi-chamber construction, White in finish, duly reinforced with 1.2 mm thick GI section. Frame shall have three track configuration, two for sliding of window shutter and one for mosquito mesh shutter. Vertical member of frame which bears the sliding shutter load shall have aluminium rail/track for smooth sliding of shutter rollers. All the four corners shall be mitered cut & thermal welded so as to form window frame. Frame shall be milled with drain and air equalizer hole in order to be water tight and for drainage of accumulated water, if any, to outer side.Shutter : The shutter of sliding window shall be made of 39w x 69h mm Extruded 3 box multi- chamber uPVC Window Profile Section of white colour having outer wall thickness of 2.5mm (+/- 0.2mm) provided with reinforcement of 1.5mm thick GI section duly mitered cut & thermal welded at all corners and fitted with uPVC glazing bead of size 22 x 20 mm with inner and outer co-extruded EPDM/TPE-Eweather seal gaskets alongwith 6mm thick ISI make plain float glass. Mesh shuttershall be made of 39w x 69h mm Extruded 3 box multi-chamberUPVC Window profile section of white colour having outer wall thickness of 2.5mm (+/- 0.2mm) provided with reinforcement of 1.5 mm thick GI section duly mitered cut & thermal welded at all corners and fitted with nylon/polymer mesh and rollers/pully. (Insert 6mm tougend glass) 58 Providing and fixingaluminum workfor doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285,fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and thedirections of Engineer- in – charge .(Glazing and paneling to be paid for separately). For fixed portionPowder coating aluminum( minimum thickness of powder coating 50 micron) 59 Providing and fixing glazing in aluminium door, window ,ventilator shutters and partitions etc. with PVS / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basicitem.)With float glass panes of 8 mm thickness 60 Providing and fixing 12 mm thick prelaminated three layer medium density (exterior grade ) particle board Grade I, Type II conforming to IS : 12823 bonded formaldehyde synthetic resin ,of approved brand and manufacture in paneling fixed in aluminium doors ,windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and direction of engineer-in-charge.Pre-laminatedparticleboardwithdecorativelaminationononesideandbalancinglaminationonotherside. 61 Grading roof for water proofing treatment withwater proffing compoundCement mortar 1:3 (1 cement : 3 coarse sand) 62 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 63 Making khurras 450 x 450mm with average minimum thickness 50mm cement concrete 1 : 2:4 over P.V.C. Sheet 1 Mtr. x 1 Mtr. x 40micron finished with 12mm cement plaster 1 : 3 and one coat of neat cement, rounding edges and making and finishing the out let complete. 64 Providing & laying broken glazed titles on roof ( broken glazed tilesnot less than 9 Kg/Sqm) on top of hot bitumen @ 1.7 Kg/Sqm. (1.40 Kg ofVG-40 (30/40 )grade and 0.30 Kg/Sqm. OfVG-10 (80/100) grade) and joints filled with cement mortar 1 :2 (1 cement:2 marble dust mixed with water proofing compund all complete as per direction of Engineer-in-charge. 65 Providing and fixing glass strips in joints of terrazo/ cement concrete floors. 40mm wide and 4mm thick 66 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :a) first layer of slurry of cement @ 0.488 kg/sqm mixed with water proffing cement compound @0.253 kg//sqm .This layer will be allowed to air cure for 4 hours. b) Second layer of slurryof cement @ 0.242 kg/sqm mixed with water proffing cement compound @ 0.126 kg/sqm This layer will be allowed to air cure for4 hours followed by water curing for 48 hours. The rates includes preparation of surface treatment & sealing of all joints ,corners,junction with polymer mixed slurry. 67 Providing&fixingprecastcementconcretecoping1:2:4mix50mmthickcompleteas per specification : 68 Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing upto any pitch including fixing with polymer coated ‘J’ or ‘L’ hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% Ultra-voilet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall confoim to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 5.0mm thick (Wt. 8.4 Kg./Mtr. Sq.) 69 Providing & fixing 12 mm thick tegular edge Glass Fibre Reinforced Gypsum False ceiling tiles of size 595 x 595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanised steel sections ( galvanized @ 170 gsm/Sqm.) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet spaced at 1200mm center to center and cross “T” of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main “T” at 600mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 21x21x0.30 mm and laying false ceiling tiles of approved texture in the grid including, wherever, required, cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats fixed to ceiling with 6 mm dia and 50mm long dash fasteners, 4mm GI adjustable rods with galvanised level clips spaced at 1200mm center to center along main T, bottom exposed width of 24mm of all T-sections shall be pre-painted with polyester paint, all complete at all heights as per 70 Providing and fixing 12.5 mm thick tapered edge gypsum board conforming to IS 2095- Part I at all height false ceiling including providing and fixing of frame work made of special sections power pressed from M.S. sheet and galvanised in accordance with zinc coating of grade 350 as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 22mm and 37mm at 1200mm centre to centre one flange fixed to the ceiling with dash fastener 12.5mm diax40mm long with 6mm dia bolts to the angle hangers of 25x25x0.55mm of required length, and other end of angle hanger being fixed with nut and bolts to G.I. channels 45x15x0.9mm running at the rate of 1200mm centre to centre to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre shall be fixed in a direction perpendicular to G.I. channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction including fixing the gypsum board with ceiling section and perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre to centre with 25mm long drive-all screws @ 230mm interval including jointing and fixing to a flush finish of tapered and square edges of the board with recommended filler, jointing tapes, finisher and two coats of primer suitable for board as per manufactures specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawing and specification and direction of the Engineer in Charge but excluding the cost of painting. 71 P & F European type white glazed vitreous china 1st quality W.C pan (IS : 2556 Mark) with P or S trap including cutting and making good the wall and floor 72 P & F water closet Seat Covers with brass hinges complete :Solid PVC (ISI marked) grade-I White for EWC. 73 P & F White Vitreous China Double Syphonic European W.C. (I.S:2556Mark) with mounted W.V.C. flushing cistern of (IS : 2556 Mark) of 10 litre capacity complete with all necessary internal fittings including cutting and making good the wall and floor. 74 P & F Indian type white glazed vitreous china 1st quality W.C. orissa pan (IS :2556 Mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor: (Size 580x440 mm.) 75 P & F Low level Flushing Cistern of 10 litres capacity (IS : 2556 mark) of approved make with complete fittings C.I. brackets duly painted, brass ball cock with ball (IS: 1703 mark) complete including cutting and making good the wall: :PVC with PVCbend as per IS : 7231 . 76 P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make, P.V.C Waste pipe with PVC nut 32 mm complete including cutting & making good the wall : Size 630 mm x 500 mm dia for counter top 77 P & F Bevelled edge Mirror/mirror with teak wood lipping around of special glass of approved make as per direction of Engineer-in-charge complete with 6mm thick commercial ply base fixed to wooden screws & washers. Size 600 x 450mm x 4 mm thick 78 Stainless Steel Sheet size 125mm dia. Heavy Quality of approved make 79 P & F Liquid Soap Container with brackets complete of approved make: C.P. brass 80 P & F Jet spray for water closet with C.P. Copper Tube flange of approved make. 81 P & F G.I. pipes (Internal Work) with G.I. Fittings excluding union (IS:1239 Mark) & MS clamps including cutting and making good the walls and floors:15 mm dia nominal boreB Class 82 25 mm dia nominal boreB Class 83 P & F G.I. Pipes (External Work) with G.I. fittings excluding union (IS : 1239 Mark) including trenching & refilling earth etc.15 mm dia nominal boreA Class 84 25 mm dia nominal boreA Class 85 50 mm dia nominal boreA Class 86 Concealed pipe in wall including painting with anticorrosive bitumen paint 15 mm dia nominal boreB Class 87 P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make: C.P. Brass bib cock,15mm nominal bore. 88 P & F Stop Cock(IS :8931 Mark),superior quality & ofapproved make: Brass 400 gm. 15mm nominal bore. 89 P & F Ball Cock (IS :1703 Mark) with Rod& P.V.C. Ball complete : Brass wt.Not less than 400 gm, 20mm. 90 P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Gyser etc.C.P. Inlet connection 15mm.Brass (IS : 8931 marked) 91 P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make :Gun-metal 15mm nominal bore. 92 Gun-metal 25mm nominal bore. 93 Gun-metal 50mm nominal bore. 94 P & F Gun-metal Non-return Valve or Check Valve (IS :Make) of approved make, superior quality:50mm nominal bore. Horizontal 95 P & F PVC Storage Tank ISI Marked (IS : 12701) indicating theBIS license No),of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved desig1000 Lt. Capacity 96 500Lt Capacity 97 Hoisting Charges for each floor :For ITEMS 2.26.1 TO 2.26.4 98 For ITEMS 2.26.5 TO 2.26.8 99 P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /makeincluding joining the pipe with solvent cement rubber ring and lubricant110mm dia 100 160mm dia 101 P&FrigidPVCpipefittings(IS:4985mark)ofapprovedquality/makeincludingjoining the pipe with solvent cement rubber ring and lubricantCoupler (socket)75mm dia 102 110mm dia 103 160 mm dia 104 Reducer 110 X 75 mm110mm dia 105 160 mm dia 106 Plain Tee75mm dia 107 110mm dia 108 160 mm dia 109 Door Y110mm dia 110 160 mm dia 111 Bend 45110mm dia 112 160 mm dia 113 Bend 87 .5110mm dia 114 160 mm dia 115 Door Bend (Top Side110mm dia 116 Vent Cowel110mm dia 117 P- Trap110mm dia 118 Gully trap110mm dia 119 Construction of manhole in all type of soil inner size 90 X 60 Cm. 300 mm thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5:10 in foundation, 20 mm thick inside plaster in CM 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring, making channels, 80mm thick stone slab covering with 40mm thick M-15 grade C.C. flooring, Cement cover with frame of 450mm dia, earthwork etc. complete as per design including disposal of surplus earth within 50 mtr. lead.Depth up to 0.5 M 120 Construction of Man hole, in all types of soil, inner size 1.5 x 1.2 M, with 450mm thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5:10 in foundation, 20mm thick inside plaster in CM 1:6, finished with floating neat cement, 50 mm thick M-15 grade C.C. flooring making channels, 80 mm thick stone slab covering with 40 mm thick M-15 grade C.C.flooring, Ferro Cement cover with frame of 450mm dia, earthwork etc. complete including disposal of surplus earth within 50 mtr. lead as per design :Depth up to 1.5 M 121 Construction of chamber in all type of soil with 300 mm thick masonry in CM 1:6 m 10 cm thick C.C. 1:5:10 in foundation, 20mm thick insider plaster in Cm 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring , earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtr. Inside size 450 x 450mm depth upto0.5 M Cement cover with frame 122 Construction of septic Tank in all types of soil with 40 Cm .thick masonry in CM 1:6, 15 Cm thick C.C bed of 1:5:10, M-15 grade C.C flooring & over stone slab covering ,80 mm thick slab ,jointing of slab in CM 1:3. Ralthal, Kharanja,50 mm thick stone partition walls, 20 mm thick plaster in CM 1:6 finished with neat floating cement, 4 Nos C.I foot rests of approved design ,two No. 450 mm dia each Ferro cementcover with frame, earth work etc. complete as per approved drawing including disposal of surplus earth within a lead of 50 mtr:- Size 400 x140x150 cm.(for 50 users) 123 Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes Type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make75 mm dia 124 110 mm dia 125 Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /makeCoupler75mm dia 126 110mm dia 127 Bend 87.5 Dg.75mm dia 128 110mm dia 129 Bend 45 Dg.75mm dia 130 110mm dia 131 Door Bend 87.5 Dg.75mm dia 132 110mm dia 133 Single Y75mm dia 134 110mm dia 135 Socket Plug75mm dia 136 110mm dia 137 Pipe Clip75mm dia 138 110mm dia 139 Nahani trap with jali 4110mm dia 140 Vent Cowel 110mm dia 141 P & F W.V.C. (IS: 2556 Mark) Squatting Urinal of standard make complete. Including cutting & making good the floor:Size 450x350mm 142 P & F lst quality WVC Urinal (IS:2556 mark) with 25mm dia G.I. waste pipe, dome waste couplings, concealed iron brackets or screws etc complete.Flat Back (small) size 456x355x265mm. 143 Construction of soakage well in all type of soil with 300 mm thick dry masonry, top and bottom 300 mm course in CM 1:6, 80mm thick stone slab, jointing of slab in CM 1 : 3, Ralthal, Kharanja, 40 mm thick M-15 grade C.C flooring , earthwork complete as per approved drawing including disposal of earth within a lead of 50 mtr.:Size 240 Cm. dia outside & 240 Cm. depth 144 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. 145 Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 Sqm on plan) including disposal ofexcavated earth, lead upto 50m andlift upto 1.5 m , disposed earth to be levelled and neatly dressed : All kinds of soil 146 Supplying and Filling in plinth with blown sand under floors including watering ramming consolidating and dressing complete including cost of sand. 147 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. :M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 40mm nominal size). 148 Providing laying, spreading and compacting specified graded crushed stone in sub-base course including premixing the material at OMC in wet mix plant, carriage of mixed material, laying in uniform layers with motor grader, F.E.loader on a prepared surface and compacting with vibratory compactorto achieve the desired density including all material, labour, mach-nery, lighting barricading and maintenance of diversion complete.[MoRTH specification Clause 401] includiong with all lead 149 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement in position to the required line, level and curvature jointed with cement mortar 1:3 (1 cement : 3 coarse sand ) including making joints with without grooves (thickness of joints except at sharp curve shall not to more than 5mm) including making drainage opening wherever required complete including painting etc. as per direction of Engineer-incharge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineerin- charge). 150 M-40,80mm thick to be used in medium- traffic ( Medium traffic is defined as a daily traffic of 150-450 commercial vehicles exceeding 30 KN laden weight, or an equivalent of 0.5 to 2.0 MSA for a design life of 20 years.) like city streets, small and medium market roads, low volume roads, utility cuts on arterial roads, etc Category A Denated units to key into each other on four faces zigzagshape as per IRC SP 63:2004 151 Construction oftubewell up to 100m depth and above to accomodate housing and assembly pipe in all types of alluvium strata by rotay drilling method with code of practice for construction and testing of tubewells (IS:2800 (Part-II) : 1991 and IS:2800 (Part-II) :1979 both amended up to date) with supply of bail plug if necessary.The work will not include cost of housing pipe and strainer pipe assembly cost, gravel and development work. Work would be deemedcompleted only after obtaining sound free water during pumping.200 mm nominal bore 152 Diameter 900 mm+C159Construction of Recharge Shaft in filter pit including Earth work Excavation , lifting excavted earth with all lift and 50 m lead and centering & shuttering evenever required. 153 Supply & fixing Pre-cast RCC Rinngs at the mouth of recharge shaft of M20 mix with40 mm thicknessDiameter 900 mm 154 Supply & lowering air line of 25mm dia, G.I. pipe B class having perforation 3 to 5mm size all arrow of G.I. pipe in Zig-Zag fashion & making air vent at top including the cost of Tee-Nipples, Elbow, Socket etc. 155 Supply and lowering vent air pipe 63mm dia rigid PVC pipe(IS 4985) mark class II (4kg per cm2 ) with required all necessary fittings including perforation of 3 to 5 mm size all around the pipe at a distance of 180 to 220mm in zig zag fashion and making air vent at top complete as per direction of Engineer incharge. 156 Supply & lying River-gravels of following sizes in recharge shaft, filter pit after screening & washing from kachha shift without deduction of voids Size 9 to 12 mm 157 Size 3 to 5 mm 158 Supply & laying of clean, clear sharp river sand of size 1 to 2mm coarse, without deduction of voids. 159 Supply of strainer pipes made of ERW M.S. black pipe ISI mark of following sizes at the site of work including required size of slotting as per IS:8110-1985. 200 mm Nominal Bore. 160 Supply and Fixing of Big steel Almirah overall size of916mm (W )x486mm (D )x1980 mm(H) with weldedconstruction. It should have the shelf thickness of 0.7mm, Back thickness of 0.8mm, Door thickness of 0.8mm (high y eld strength) and all other components shall have a thickness of 0.9mm. The Almirah should have a Mazak handle and Three way locking mechanism with Shooting Bolts.It should have a height wise adjustable shelf mounting .Itshould also have a M10 Screw type Leveller with Hex plastic base. The finishing shall include Epoxy powder coated. Plenty of colour options and shelving options shall be available ISimarka brand (Godrej or equivalent) as per approved colour, shape,design,type by engineer in charge. 161 Supply and Fixing of small steelAlmirah overall size of 760mm (W )x455mm (D )x1325 mm(H)with welded construction. It should have the shelf thickness of 0.7 mm, Back thickness of 0.8mm, Door thickness of 0.8mm (high yield strength) and all other components shall have a thickness of 0.9mm. The Almirah should have a 2 Mazak handle and Three way locking mechanism with Shooting Bolts.It should have a height wise adjustable shelf mounting.It should also have a M10 Screw type Leveller with Hex plastic base. The finishing shall include Epoxy powder coated.Plenty of colour options and shelving options shall be available ISimarka brand (Godrej or equivalent) as per approved colour, shape, 162 Providing and supplying Canning Chair of size 455mm X 580mm X880mm. IIshould have wooden canning support at back and bottom supported by steel frame 3 2mm thick,powder coated round pipe with full armwooden handles onsides and other fittings as per direction of enaineer in charae. 163 Providing and supplying Canning Chair of size 455mm X 580mm X880mm. IIshould have wooden canning 4 support at back and bottom supported by steel frame2mm thick,powder coated round pipe without woodenhandles as per approved colour, shape,design,type by 164 Providing and supplying Officer high back Chair, The seat and back are made up of 1.2 cm thick hot pressed plywood, upholstered with fabric and moulded Polyurethane foam with PVC lipping all around.The back foam is designed with contoured lumbar support for extra comfort. BACK SIZE:65.0cm.(W) X 71.0cm.(H) SEAT SIZE:65.0cm. (W) X 65.0cm.(D) andreinforced with M.S. insert. The armrests are scratch and weather resistant. The armrests are fitted to the seat with seaUarmrest connecting strip assembly made of steel.The center pivot mechanism Is designed with the followingfeatures:360 revolving type.Tilt tension 5 adjustment. Upright locking.The pneumatic height adjustment has an adjustment stroke of 12.5 cm..The pedestal Is made of HR steel and fitted with 5 nos.twin wheel castors (castor wheeldia. 5.0cm.). The pedestal is covered with a P.P moulded cladding for modem and aesthetic looks.The pedestal is 65.0 cm. pitch-centre dla.(75.0 cm with castors). The twin wheelcastors are injection moulded In 30% Glass Filled black Nylon, as per approved colour, shape,design,type by engineer In charge. 165 Providing & Supplying table or size 1500mmx900mmx750mm, Top should be nnished with 18mm MDF Bos:d post formed Both side with 0.6mm laminate of approved make & design & with appropriate balancer on the bottom or the top. All verticals supportsincluding Modestypanel should be of 18mm prelaminated MDF Board with 2drawers & 16 Swing door per approved design.The drawers to beprovided with ai:proved handles and fixed on Telescope channels.AppropriateEdge Bendings to be provided where necessary with PVC beading 2mm thick to be provided. Footrest to be provided with 1Bmm MDF prelaminated board of the same color code.P&F PVC wire managers capslo be provided on the table top, as approved colour,shape, design,type by engineer In Charge 166 Providing & Supplying side table of size 900mmx450mmx750mm. Top should be finished with 18mm MDF Bos:d post formed with 0.6mmlaminate oras same as the Table,approved make & design & with appropriate balancer on the bottom or the topAllvert icals supportspanel should be of 1Bmm prelaminated MDF Board. Having 2Drawers & 1Swing7 door CPU unit. Keyboard tray, with mouse rest to beprovided.Appropriate Edge Bendings to be provided where necessary with PVC beading 2mm thick to be provided as per design.The drawers to be provided with approved handles and fixed on Telescope channels.P&F PVC wire managers caps to be provided on the table top, as per approved colour, shape,design, 167 Providing and $Upplylng table of size 1200mmX 750mmX750mm high as per design. The table top should be finished with 0.6mm thick laminated postrorming on 18mm thick MDF board.The 3 drawer unit (provided withlocking mechanlsm)and all other8 exposed vertical supports should be finished with steel members or approvedshade,colour and make.Appropriate moulding/edge bindingto be provided where necessary with PVC beading 2mm thick lo be provided as per approved colour, shape,design, 168 Providing & Supplying Computer table of size 900mmx450mmx750mm.Top should be finished with 18mm MDF Bos:d post formed with 0.6mmlaminate or as same as the Table,approved make & design & withappropriate balancer on the bottom or the topAllverticals supports panel should be of 1Smm 16.00 Each 12100.00 1g3500.oo prelaminated MDF Board. CPU uni Keyboard tray,with mouse restlo be provided.Appropriate EdgeBendlngs to be provided where necessary with PVC beading 2mm thck to be provided as per approved 169 Providing & Supplying depository/cashcabinet made up of CRCA steel with external size or 5g1 x 460 x 460 mm,2 nos of lockable drawers and single door cabinet fitted 3.00 Each 22848.00 68544.00with 6 leverlock system 1vith completein all respect. (approx weight 160 kg to 180 kg) as per approved 170 Book Case - 4 Door Book Case shall have the configuration or 914mm(W)x320mm(D)x1742mm(H). The unique design provides the right rigidity to the Top hinged doors ,which shall faci itate easy use.The Book Case shall be made fromprime quality steel. It shall have a Rigid Knock Down Conslructlon.The TopPannel, Back Pannel and Side Pannel are made from 0.7mm high yield CRCA andother components from O.Smm CRCA. Each door shall have a 6 Lever Cam Lock with Comrron Key. 3mm thick glass should beused in each door for clear inside vision whih shall besecured Ina metalframe through a rubber gasket.11 Scissor Mechanism should be providedin each door for 20.00 Each 17248.00 344960.00receding Inside the top or every compartment andItshall ensure parallel and smooth movement. Each door should be provided with plastic side end caps as handle which Is easy to grip.Each compartment shall have a storage shelf with good capacity. The 4 Door Book Case shall have 18mm PLB Top straight edge with PVC lipping.The Hn shlngshall Include Epoxy powder coated.Complete work as per the as per approved colour,shape,design,type by engineer in charge. 171 150 cm high fencing of precast R.C. posts of 15cmx15cm tapered to 10x10cm at top placed at every 3m apart 30cm in ground embedded in cement concrete 1:3:6 (30x30x45cm) corner and every tenth posts to be strutted with same R.C. posts provided with 6 horizontal lines and two diagonals of black barbed wire between the two posts fitted and fixed with G.I. staples including earth work in excavation etc. complete 172 FIRE FIGTHING WORKProviding, Fixing, Jointing, Testing & Commissioning of Heavy duty MS C class (Heavy) pipes conforming to IS 3589 / 1239 part-I for hydrant and sprinkler applicationsincluding cutting, screwing, welding etc. & forged steel fittings like elbows, tees, tapers, reducer, gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps, hanger and nuts bolts including cutting hole and chase in brick or RCC walls/ slab and making good the same. complete with painting of one coats of Red Oxide and two or more coats of synthetic enamel paint of requiredshade complete as required. (Pipe to be tested @ 10Kgf/Sqcm for 2 Hrs.). All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 150 mm dia 173 100mm dia 174 80mm dia 175 50mm dia 176 40mm dia 177 32mm dia 178 25mm dia 179 Supplying and fixing first -Aid Fire hose reel Drum wall mounted swinging type with MS construction powder painted in post office Red, conforming to IS 884-1985 with upto date amendments, complete with the following as required.(A) Thermoplastic / Rubber Hose(B)20 mmdia UL, FM Bronze / SS nozzle with 5mm orifice (C)Drum and brackets for fixing the equipments on wall.(D) Connections from riser with 20/25 mm dia Brass/GM gate valves with screwed end and conforming to IS:778 Class-1through Forged steel Screwed Union & M.S. pipe. Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . With 30 m x 20 mm High Pressure Braided Rubber Hose as per IS:5132 - 1969and Bursting pressure 42 Kg/sqcm 180 Supplying and fixing of SS 304 Single / Double headed oblique pattern hydrant landing valve (internal/external) with 75 / 100 mm dia flanged inlet & 63 mm dia instantaneous type female outlet coupling with cast iron wheel complete with ABS cap and chain and all accessories as per IS:5290-93 (Type-A) in cluding matching flange (14 mm thick),nuts, bolts, washers, gaskets,etc as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Single Headed with 75 mm Dia. Flanged Inlet 181 Supplying and fixing of flexible hose made with 100% polyester, black EPDM internal rubber lining with External coat of synthetic elastomer (IS:636, type-A)63 mm dia, 15 mtr. Long RRL hose pipe with instanteneous type 63 mm dia SS-304male and female couplings(IS:903) duly bound and riveted to hose pipes with copper rivets and SS wire etc. as required.Appropriate Test Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. 182 Supplying & fixing SS-304 Short Branch Pipeconforming to IS: 903:93 fitted with 20mm (nominal internal diameter)bore nozzle, for projecting water in form of solid jet. The Branch shall have 63mm Male Instantaneous Inlet, suitable for use with 63 mm size Fire fighting hoses. H.P. tested to 21 kgf/cm² for 2.5 minutes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 183 Supplying and fixing of 750 mm x 600 mm x 250 mm Outdoor application Fire Hose Cabinet made of 1.6 mm thick MS sheetDuly powder coated in red color externally and white internally with 6 mm thick glazeddoors with Expanded Metal 2 mm thick Jali including necessary locking arrangement suitable to accommodate 2 Nos 15 Mtr. Long RRL Hose and 1 No. branch pipe on Existing Wall / Angle Iron Frame as required. (Cost of MS structure for mounting Frame is to be Paid Extra) All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 184 Providing and fixing of Fire / Electrical Shaft Door made frompowder coated (50 Micron) aluminiumpartialy glazed with 6 mm thick glass and Partialy/ Fully Louvered with Outer frame of AluminiumSection of Size 100 mm x 45 mm x 1.5 mmand Shutters Top, Middle & sideSection of Size 82 mm x 45 mm x 1.5 mm, Bottom Section of Size 110 mm x 45 mm x 1.5 mmComplete with Hinges, Tower bolt, Handle, Aldrop, Locking Arrangement including dash fasteners of required dia and size, necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. as per drawings and the directions of Engineer-in-charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 185 Supplying, Installation, Testing & Commissioning ofElectrical Driven fire fighting duty Terrace pump as per TAC andIS 12469-1988., Factory assembledin Pump make OEMsuitable for automatic operation and consisting of following details given asA, B, C, D, E, F, G and H.(A) Horizontal End suction Centrifugal Back pull type pump complete for delivery of below mentioned discharge and Head(B) Material of construction : Pump Casing - Cast Iron, Impellor- Bronze, Shaft - SS 410, Packing - Mechanical Seal(C) Squirrel cage induction motor (IE-3 Class) suitable for 3 phase, 415 V, 50 HZ, Ac supply , Class -F Insulation, Synchronous speed not Exceeding 3000 RPM, T.E.F.C confirming to IP:55 , of required HP suitable for the above pump ,along with flexible (Love Joy type) coupling , coupling guard complete in all respect .(D)Common bed plate fabricated frommild steel channel for installation of pump and Motor including anti vibration pads.(E) The Hydrostatic tests (2 times of design operating head or 1.5 times the shut off head whichever is higher) and performance tests (to determine developed head, Pump BHP and efficiency v/s Flow) of pumps along with trip test shall be carried out at manufacturer’s works in Virtual / Physical presence of Department’s representatives.(F) Physical & Chemical Test reports of i) Pump casing (ii) Impeller (iii) Shaft (iv) Shaft sleeveand Dynamic Balance certificate is to be submitted by OEM(G) Suitable size Reinforced cementconcreat (M-30) foundation with foundation bolt, Nozing Angle of size 40mm x40mm x5 mm ( Cost of RCC Foundation to be paid Extra )(H) Weather proof hood fabricated from 5mm thick UV stablised FRP sheet supported by 50 mm x 50 mm x 5 mm Angle Iron fram above pumpset to protect it from weather All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR 450 LPM with 35 mtr head 186 Supplying and fixing Inlet Breeching Connection of CI body with Gun Metal male instantaneous inlet couplings with Inbuilt NRV, Drainage Connection with 50 mm Brass gate valvecomplete with PVC blank cap and chain as required for 150mm dia Outlet with 1 no. Matching Flange (Minimum 16 mm thick), nuts, bolts, washers, gaskets,etc as required of following Ways. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 4 Way 187 SITC of installation control valve of cast iron body and brass/bronze working parts comprising of water motor alarm, bronze seat clapper, and clapper arm, hydraulically driven mechanical gong bell to sound continous alarm when the wet riser/Sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, with 2 no. Matching Flanges (Minimum 16 mm thick), nuts, bolts, washers, gaskets,etc as required of following sizes.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 150mm dia 188 Supplying and Fixing of PN 16 Cast Iron Dual Plate Wafer Type Check Valve / Non return valve with SS / Bronze flap complete with 2 no. Matching Flanges (Minimum 16 mm thick), nuts, bolts, washers, gaskets,etc as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 80 mm dia 189 100 mm dia 190 150 mm dia 191 200 mm dia 192 Supplying and Fixing of PN 1.6Butterfly Valve (Wafer Type) with S.G Iron Disc and confirming to IS:13095 complete with 2 no. Matching Flanges (Minimum 16 mm thick), nuts, bolts, washers, gaskets,etc as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 150 mm dia 193 100 mm dia 194 80 mm dia 195 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 6 kg 196 Supply & Fixing of CO2 type Fire Extinguisher conforming to IS:15683:2018, charged with CO2 gas (purity 99.7% conforming to IS 15222), Powder coated Internal & External Surface Manganese steel ISI marked as per IS 7285 cylinder body , Wheel type Forged brass release valve ISI Marked as per IS 3224 with Inbuilt safety release device ((Fusible plug and Rupture Disc Type), 1.0 Mtr. Metal wire braided hose having minimum bursting pressure of 140 Kgf/cm2, Horn with metallic thread connection, QR code for Product Traceability,including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSRCapacity 4.5 Kg. 197 Supplying and Fixing ofGalvanized Mild Steel fire bucket Confirming to IS: 2546 : 1974 with one coat of primer and two coat of enamel paint of approved shade on Angle Iron ( 50 x 50 x 5 mm) Stand of Size 800 x 1240 x 400 mm with MS 22 SWG Galvanized Canopy, 4 Hooks for Bucketsincludingassociated civil works etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 198 SITC of UL 10th edition / EN54 / VDS certified Addessable Manual Call point (MCP) with LED/ FIRE Indication Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 199 SITC of UL 10th edition / EN54 / VDS certified Addressable sounder with strobe light,Loop Powered / Direct powered from FACP with sound level 90 dB and programmablefrom the panel etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 200 SITC ofResponse Indicatorfor indicating the activation of the Remotely located Detector for Conventional type detectors as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 201 SITC of EN / LPCB/ UL listed / approved conventional automatic fire Alarm Rate of Rise cum fixed temperature thermister typeHeat Detectors , 12 / 24 volt D.C., visual alarm indicator (LEDs) Blink - green in stand by and Steady - red in alarm complete in all respectswith baseas required.including the cost of all accessories Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 202 SITC of EN / LPCB/ UL listed / approved conventional automatic fire Alarm Optical/Photoelectric type smoke detectorsof photo-optic sensing chamber, 12 / 24 volt D.C., visual alarm indicator (LEDs) Blink - green in stand by and Steady - red in alarm complete in all respectswith baseas required.including the cost of all accessories Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 203 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR2 x 1.5 sq.mm 204 3x 1.5 sq.mm 205 Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specification GR / WIR/06-03 March 2002in existingsurface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR4 Pair 206 2 Pair 207 Supplying and fixingof CE certified and UL listed GI wire mesh cable tray made from spot welded steel wirehot dipped galvanised between 60 and 80 microns of zinc as per BS 729including horizontal and vertical bends, reducers, tees, cross members and other OEM made accessories like wall clamp, hold down clamps, Earthing terminal, brackets as required, and duly suspended from the ceiling with electro-zinc coated TF rods,etc. as required of following sizesAll as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .500 mm x 100 mm x 6 mm 208 300 mm x 100 mm x 6 mm 209 SITC of UL 10th edition / EN54 / VDS certifiedActive Repeater Panel for Fire Alarm System with inbuilt networking port (both RS485 & Ethernet),Serial port for printer,two supervisory inputs,two position key switch and USB port for programming. The Repeater Panel shall allow users to acknowledge, reset,silence, program, view hisory events.etc (All functions similar to main panel)The user interface of the repeater panel shall be same as the Main Controller with menu driven user interface with smart search.including the cost of all accessories Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 210 SITC of PA system Operator Console of following wattage to be installed withConventionalfire alarm systemcomplete with following capacity , channel mixing amplifier , 1 no cardioids goose neck microphone , 1 no professional grade cassette deck/ CD Player , 16 zone floor selector console ,equipment rack complete in all respects. PA system shall be coupled to the Fire Alarm System. Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 1x 240 Watt 211 SITC 6 watt Speakermounted in M S sheet box with perforated front mesh for PA and Emergency System. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 212 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSRMedium point (up to 6 mtr.) 213 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSRLong point (up to 10 mtr.) 214 Long point(up to 10 mtr.) 215 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSRMedium point (up to 6 mtr.) 216 Long point(up to 10 mtr..) 217 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR3x 1.5 sq.mm 218 3x 2.5 sq.mm 219 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 220 2 x 6.0 sq. mm. + 1 x 4.0 sq. mm. 221 2 x 6.0 sq. mm. 222 4 x 10.0 sq.mm 223 4 x 16.0 sq.mm 224 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 225 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) 226 Providing & Fixing ofof BLDC Technologyventilating fans , single phase with PVC impeller, ABS body, Double Ball bearing, automatic back lower shutterincluding making connection, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .250 mm sweep with Min. Air delivery 1150 cmh, 1300 RPM 227 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRSingle pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating 228 Double pole MCB(With B/C curve tripping Characteristics) 6 A to 32 A rating 229 Three pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating 230 50/63 A rating 231 100 A rating 232 Four pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating 233 50/63 A rating 234 Providing & Fixing of 240/415 V Residual current circuit breaker (RCCB) conforming to (IS:12640-1)/ IEC 61008 -1 , rated 4 KV impulse withstand voltage truly current operated and shall operate on CBCT mechanisum, provision for pad lock,min. operation 10,000 upto 63 A rating and5000 for 100 Aratingand minimum phase termination capacity of 35 sq.mm. rigid wire, IP 20 contact protection with existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRTwo pole 30 mA sensitivity6A-32 A rating 235 40 A rating 236 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRGlazed door (single phase) IK-09 and IP-43 with Metal end box8 Way (8+2) 237 Metal door (Three phase) Per phase isolation, Horizontal IK-09 and IP-43 with Metal end box6Way(Incomer 8,Sub Incomer2+2+2) 238 Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box withprovision of incomer suitable for MCB / RCCB and SP / TP MCB as outgoing ,made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted with reversible door (for double door DB only ) complete with insulated 100 A rating copper bus bar, neutral bars with shrouds, earth bar , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR6 Way(8+18) 239 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure A attached with this BSR 240 Providing & Fixing of modular type switch/ bell push duly ISI marked (IS :3854) with CM/L no. printed and made out of unbreakable and fire retardant vergin UV Stabilized Polycarbonatewith brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,minimum width ofswitch toggle( PUSH PART ) should not less then 20mm,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 25 Amp.2 Moduleswitch With LedIndicator 241 Providing & Fixing of modular type lockable feature socket dulymade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR25 Amp. 2 Module Socket 242 Providing & Fixing of following modular accessories as per PWD specification for electrical Works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSRRJ-11 telephone jack Double line 243 RJ-45, Cat 6 computer jack with shutter 244 Providing & Fixing offollowing size mounting grid plates with cover plates made from fire retardent UV established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .1 Module 245 4 Module 246 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR5 step fan regulator 2 Module 360 dgree rotating 247 Plate Earthingas per IS:3043 with Hot dipped G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying3 to 4 mtr. below the ground level with 20mm dia. G.I. B class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. and embodying the pipecomplete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 248 Supply & Laying following size earth stripin horizontal or vertical run in surface by means of Earth strip DMC Insulatorincluding riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 25mm x 6mm G.I. ( Hot Dipped) Strip 249 Supply & Laying following size B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with accessories like bend, socket etc.for laying earth conductor/ strip / cable in ground/ surface/ recess as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 40 mm dia. 250 Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminiumhousing with in built driver, System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .1170mm(+/-10%) LED batten with min. lumen output 2200 lm 251 570mm (+/-10%) batten with min. lumen output 1000 lm 252 Providing & Fixing of IP20, 2x2 LED Surface/ Recessedmounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 ,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Minimum lumen output 3600 lm 253 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing.OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Minimumlumen output 650 lm 254 Minimum lumen output 1950 lm 255 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 256 Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specification GR / WIR/06-03 March 2002in existingsurface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR2 pair 257 Supply and Laying of PE Insulated, PVC Inner Sheathed, armoured & PVC Sheathed Telephone Cable. with 0.5 mm thick Solid Annealed Bare Copper Conductor as per IS: 8130/84 telephone cable confirming to TEC specificationsGR/WIR 06/03, Mar.-2002 in existing pipe / open trench / Cable tray / on surface including making necessary connection, testing etc. as required of size. For additional technical parameters of product / work refer Annexure A attached with this BSR50 pair 258 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR25 mm 259 Supplying and fixing of ISO Certified company made Krone module with base frameas per PWD specification for electrical Works, in the recess / surface made out of 16 SWG sheet steel box, front openable, having locking arrangements duly powder painted., including dressing, ferrulingandpunchingof telephone cable with krone tool etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .50 Pairs 260 CCTV SURVEILLANCE WORKSupply, Installation, Testing and Comissioning of Rack mounted 19 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panelswith Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Modular Patch Panel Loaded with Cat -6A I/O 261 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 262 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Cat 6A, Sheilded Information Outlet 263 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Single Aperture 264 Supply, Installation, Testing and Comissioning of Rack mounted 19 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panelswith Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Modular Patch Panel Loaded with Cat -6A I/O 265 Supply & Installation of IP-20 & IK-08 , UL ListedWall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with UMarking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. Accessories like: 1 No of 19 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastneretc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 9 U Rackwith Width 600 mm & Depth 400 mm + 100 mm 266 Supply , Installation, Testing and Comissioning of Managed Layer-2 Intelligent PoE Giga Ethernet Switch providing 24 x 10/100/1000 MBPSPoE Giga Ethernet ports and with min 4 SFP Giga Ports (provision for Fiber Giga connectivity) with provision of minimum Stacking of 06 Switches with minimum 370 Watt PoE Power Budget with related LAN Base Software including making connections etc as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 267 SITC of 2 MP IR Fixed Dome Network Camera -1/2.7″ Progressive Scan CMOS, 1920 × 1080 at 25fps, 2.8 mm Fixed lens, 0.002Lux at F1.4, 0 Lux with IR on, ICR, ONVIF (PROFILE S, PROFILE G, PROFILE T), support H.265, H.264, MJPEG, 120db WDR, 3D Digital Noise Reduction, Three individually configurable stream, 12 VDC & PoE, IR range: 40m, Support on-board storage up to 256 GB (SD card not included), IP67, Edge Analytics- Line crossing detection, Intrusion detection, Motion detection, Video tampering, UL, CE, FCC certified. 268 Supply Installation testing and commissioning of 32 Ch Network Video Recorder- Connect Up to 64 IP Cameras, Up to 12 Megapixels Resolution, HDMI1/VGA1 and HDMI2/VGA2 outputs provided, atleast one HDMI output with 4K (3840 × 2160), atleast one VGA output with 2K (2560 × 1440) resolution, Support H.265/MJPEG, Supports N+1 hot spare system, Supports RAID0, RAID1, RAID5, RAID6 and RAID10, Supports HDD hot swap, Incoming Bandwidth 320 Mbps, 8 SATA Hard Disks, 1 × eSATA interface, ANR Technology, 8 SATA interfaces for 8 HDDs and capacity of each HDD upto 10 TB, Front panel: 2 × USB 2.0; Rear panel: 1 × USB 3.0, Alarm I/O 16/4, RS-232, RS-485, 2 RJ-45 10 /100/1000 Mbps self-adaptive Ethernet interface,Multiple network monitoring: Web viewer, CE, FCC, UL certified. with 30 days backup capacity asrequired. 269 SITC of professional PC alongwith printer and other accessories as required having minimum i7 processor, 8 GB graphic card 1 Tb SSD as per requirement. 270 SITC of 42 inch full HD professional LED display for CCTV monitoring. 271 External Electrical WorkS I T C of star ratedAluminium wound distribution Transformerof following rating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11,ONAN Cooled & as per BEE star - 1 & BIS approved as per IS 2026- 1977 & lossesas defined as per 2014 (Fourth Revision) Level-1 . including standardaccessories like conservator, silica gel breather, radiator, fins, HT cable box & LT cable boxes, temperature rise in winding/oil 35-40 degree C upto 200 KVA & 40-45 degree C for above 200 KVA, ISI marked drain valve, Dial type Temperature gauge, first filling of transformer oil as per IS :335-1953, Epoxy based paint,including carrying of pre-commission Testing & Charging of Transformer complete in all respect .The Transformer shall be subjected to routine factory tests (as per IS:2026 and IS:1180) including testing from CTLof discombefore charging of transformer & complete installaion must be certified from Electrical Inspectorate office as per Indian Electricity rule, (CTL testing charges and Electrical Inspection charges shall be reimbursed by the department to the contractor). All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 100 KVA 272 SITC of PLC Based Auto main failure (AMF) Panel fabricated from CRCA sheet steel 2 mmThick , Powder coated finish , Engine Start & Stopcommands, control Relays , Ammeter & Voltmeterwith selector switches, Control & 2 nos 4 pole Power Contactors with 2 no. of required size 4 pole MCCB, Timers, Electronic Hooter ,Visual & Alarm indication for faults, UPS, operator interface panel complete in all respect suitable for following capacity DG sets: Appropriate Test Certificate/ report of product/accessories from OEM/Panel Manufecturer shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .20 to 40 KVA 273 Supply & fabrication steel structure with MS channel / angle / joist / ISMB / sheet etc. including welding, rivetting, cutting, nut & bolt , one coat of primer & two coat of enamel paint etc. as requiredcomplete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 274 Providing & Laying XLPE insulated three core ArmouredAluminiumcable for working voltage 11 K.V.(E) confirming IS :7098 P - 2withH4- Grade electrolyticaluminium conductor confirming to IS: 8130 class-2 of purity >99.6 %, Insulation Screening: Extruded Semiconducting Compound followed by helically wrapped Copper Tape, round / flat strip armouring of cables , Inner / outer sheath PVC type ST-2 confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810 All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .3 core 150.0 Sq.mm 275 MAIN LT PANELSITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andOther parameters requiredas per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-(a)Thickness of CRCA sheet shallbe 2.0 mm,cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided(b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.[c)Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only.All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar/ Flexible wire for Interconnection between Main busbar and Switchgearis to be Paid Extra )(d)Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging.(f)Floor mounted panel shall be mounted on Base frame of ISMCchannel size 100 x 50 x 5 mm( to be paid Extra )(g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out.(h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 276 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR4 pole MCCB With Thermal Magnetic release160 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 277 up to 100 Amp , 10 kA, fixed O/L & fixed S/C setting 278 Supply and fixing of following accessories for Moulded case circuit breaker (MCCB)compatible to main MCCB OEM as per PWD specification for electrical Works, conforming to IS/IEC 60947 P - 2 :2003 including making connection etc complete in all respect. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Shunt Trip Release 279 Under Voltage Release 280 Extended Rotary Handle 281 Auxiliary contact 282 Spreaders for 250A, 4 Pole MCCB 283 Spreaders upto 125A, 3 Pole MCCB 284 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRSingle pole MCB (With B/C curve tripping Characteristics) 0.5 A to 5 A rating 285 Providing & Fixing of ISO certified company made Four Pole By pass Change Over Switch conforming to IS:13947(Part 3) : IEC:60947-3-1 and IEC:60947-6-1, Open execution type in the following ratings.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .100 A 286 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRSingle pole MCB (With B/C curve tripping Characteristics) 0.5 A to 5 A rating 287 Double pole MCB(With B/C curve tripping Characteristics) 6 A to 32 A rating 288 Four pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating 289 50/63 A rating
Contract Date : Ref. Documents   |   Contract Value : Ref. Documents
BRR : 9189203 Renovation And Improvement Work At 33 Kv S/S Katcheri. - 1 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils(B-44/1.8) 2 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level.1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40mm nominal size). (B-54/3.1.2) 3 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level.1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size). (B-54/3.1.6) 4 M-40,80mm thick to be used in medium- traffic ( Medium traffic is defined as a daily traffic of 150-450 commercial vehicles exceeding 30 KN laden weight, or an equivalent of 0.5 to 2.0 MSA for a design life of 20 years.) like city streets, small and medium market roads, low volume roads, utility cuts on arterial roads, etcCategory‘B’ Denated only two side like I,Z,T shape etc. as per IRC SP63:2004B-11.38.3B 5 Steel work in built up tubular trusses including cutting, hoisting ( height upto 10 m)fixing in position and applying a priming coat of approved steel primer, welded and bolted including special shaped washers etc. complete.Hot finished welded type tubes.B-9.3.1 6 Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/ vertical or curved surfaces)excluding the cost of purlins, rafters and trusses and including cutting to size and shape whenever required.0.63 mm thick with zinc coating not less than 275 gm/m2B-10.1.3 7 Random Rubble stone masonry with hard stone in superstructure aboveplinth level and upto five levelabove 30cm. thick walls in : Cement Mortar 1:6 ( 1-Cement : 6-Sand). Add extra for Wall upto 30cm. and less thickness. (B-69/6.2.6+6.3.4) 8 Add extra for facing as per design and detailed specifications including additional cost of stonesCourse rubble facing First Sort. (B-40/6.4.1) 9 Add extra for facing as per design and detailed specifications including additional cost of stones Course rubble facing Second sort. (B-70/6.4.2) 10 Add extra for rock facing with proper projection and chisal dressing of edges of stone 2 line dressing for building corners,jambs including uniform joints.(B-41/6.4.8) 11 Pointingonstonemasonryincementsandmortar 1:3 (1 cement : 3 sand) : Deep groove pointing(B-143/12.31.3) 12 Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix(B-59/4.1) 13 Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcementfor Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.M20 grade Nominal Mix / Design Mix(B-59/4.3) 14 Half brick masonry in Superstructure , above plinth level upto floor Vlevelusing bricks of designation 75Cement mortar 1 : 6 (1 cement : 6 coarse sand) (B-66/5.8.3) 15 Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc.(B-61/4.9) 16 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for : Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc. (B-61/4.10.2) 17 Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. (Original producers who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786) Cold twisted deformed bars (IS : 1786). (B-62/4.13.1) 18 Providing and laying cement concrete including curing, compaction etc. complete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, levelling course etc up to floor five level excluding the cost of centering and shuttering. M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size). (B-55/3.2.4) 19 P & F 1st qualityVitrified Porcelain Polished tiles on floor, skirting and steps etc.in different sizes (thickness to be specified by manufactuer) with water absortion less than 0.08% and conforming to IS 15622 of approved make in all colour and shade,laid with 20 mm thick CM 1 : 4 including grounting the joints with white cement and matching pigment etc complete.size 600 mm X 600 mmB7.18.2 20 Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish : 25mm thick (B-139/12.3.1) 21 Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish : 20mm thick (B-139/12.3.2) 22 Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirmingto IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4). (B-86/ 7.13) 23 Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). (B-86/ 7.12) 24 Providing and fixing pressed steel door frames confirming to IS 4351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applyinga coat of approved steel primer after pre-treatment of the surface including filling with CC 1:2:4(M15 grade) complete as directed by Engineer-in-charge : Profile C(B-99/9.6.2) 25 Providing and fixing steel glazed window frame made out of 80x40 mm hollow sheet section of 16 gauge thickness, joint mitred weldedand grinded including hold fast of steel lugs 13mm x 3mm and 15 Cm long embedded in C Cblock 15 x 10 x 10 Cm of 1:3:6 nominal concrete and including fixing of pivoted hinges of superior quality, window shutters made out of 50 x 25.0 mm hollow steel section 15 mm paitam of 18 gauge thickness, joint mitred and grinded including 10mm x 10mm square bars welded to framefor paitam fixing float glass 4mm thickpanes with glazing clips and metal sash putty andfixing of shutters frames peg stay, U shape handle 100 mm long, tower bolts 100 mm long of steel powder coated superior quality including fixing and jointing with frame hinges priming coat with steel primer complete in all respect as per direction of Engineer-in –charge Window openable. (B-102/9.28.1) 26 Supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150mm distance. (B-102/9.26) 27 Providing and fixing Square bars or other flat welded to window, ventilatiors etc. (B-102/9.27) 28 6 mm thick cement plaster to ceiling of mix1:3 (1cement : 3-fine sand) (B-139/12.5) 29 Supply and fixing chittar or equivalent stone slab perchits with making edges and top surface level in cement mortar 1:3 complete finishedAdd extra for span more than 2.15m span Soorsagar or eqvt. White AshlarB-6.51.2 30 Providing and fixing of double leaf steel shutterfor cupboard, the frame is made of pressed steelISI section 80x25 mmx1.25 mm thickwith 1.00 mm MS sheet to spot welded including holdfasts of 15x3mm, MS oxidized fittings such as butt hinges, sliding doors bolts, handles, tower bolts and twin peg etc completeincluding applying priming coat of approved steel primer of red oxide zinc chromate andspray painting in approved shade with decopaint of approved quality complete as per direction of Engineer In Charge (B-104/ 9.39) 31 Supplying and fixing in walls machine cut and polished stone shelves, tands andin CM 1:3 with machine cut edges : Kota stone minimum 30mm thick. (B-72/6.17.3) 32 Providing and fixing welded mesh/expanded metal mesh in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. complete (excluding frame work) of size.Welded mesh 25 mmx 25 mm x 2.1 mmB-9.38.3 33 Providing & laying broken glazed titles on roof ( broken glazed tilesnot less than 9 Kg/Sqm) on top of hot bitumen @ 1.7 Kg/Sqm. (1.40 Kg ofVG-40 (30/40 )grade and 0.30 Kg/Sqm. OfVG-10 (80/100) grade) and joints filled with cement mortar 1 :2 (1 cement:2 marble dust mixed with water proofing compund all complete as per direction of Engineer-in-charge. (B-109/10.24) 34 Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesinin glue both sides with approved steel fittings complete as per annexure A: 30 mm thick . Commercial Veneer both side (B-93/8.13.2.1) 35 Painting with synthetic enamel paint of approved brand and manufacture togive an even shade : Two or more coats on new work (B-146/ 12.46.1) 36 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding:Newwork(twoormorecoats)overandincludingscrappingandprimingcoatwithcement primer.B-144/12.37.1 37 Supply and fixing Jodhpur sand stone Machine cut Dash, Coping,sill,lintel fixed in cement sand mortar 1:4. 9 cm (3.5) thick(B-82/6.88 (ii)) 38 Providing and fixing of Un-perforated Metal Tile Ceiling Systemcomprisingof Tile of 600mm wideand 600mm longmanufactured out of 0.7mm thick aluminiumalloy 3105with bevelededge of 4.15mm width height of 32mm. The Tilewillbe manufactured on advanced equipment that includes severalleveling stages in the manufacturing process by approved manufacturers . Tile ends will be raisedwith pips and slops to ensure positive engagementinto the spring to enable for de-mounting of individualpanels. The Tile sides will be sufficientlyhigh to ensurea minimum deflection across the length of Tile. All Tileswill be bevel edged. The Tile shallbe epoxy polyester powder coating with in white colour. The Tile shallbe cllppedinto clip in rail of 0.5mm thick GI. inform of a grid system using a cross connector. The clipin rail shallbe supported from slab by means of rigidSuspension of 4mm G .I rod, Hold on Clamp with Clip. POWDER COATING SPECIFICATION: Aluminium PANELS, cleaned through eco friendly cleaning ,process and powder applied through electrostatic charged Automatic Carona technology spray guns and cured in combination of Infrared & hot air oven in a certified plant as Akzo International approved applicator . B-10.40 39 P & F UPVC SWR. pipes grade B for sciland wast discharge system (IS :13592-1992 marked) of approved make110 mm dia (S-257/3.44.2) 40 Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge:In cement mortar.B-12.9.2 41 P & F Indian type white glazed vitreous china 1st quality W.C. orissa pan (I.S. : 2556 Mark) with 100mm vitreous china P or S trap including cutting and making good the wall and floor:Size 580x440mm. (S-217/1.2.2) 42 P & F WVC wsh basin (Ist quality, I.S. : 2556 Mark) of approved make with C.I. brackets duly painted, 1 No. 15 mm C.P. Pillar cock (I.S. : 8934 Mark) & 32 mm C.P. brass waste coupling of approved make. 25 mm G.I. waste pipe complete including cutting & making good the wall. : Size 510 mm x 400mm (S-/1.36.2) 43 P&F looking mirror of PVC frame ofappd make ( Atul or eq ) size 500x400 mm(S-223/1.45.1 ) 44 Const of CC chamber 125 mm diafloor with stainless steel grating( S-255/ 3.39.4) 45 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.,) 15 mm nominal size (B-240/2.38.1) 46 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.,) 25 mm nominal size (B-240/2.38.3) 47 P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make.Brass 400 grm. 15 mm nominal bore (S-232/2.7.1) 48 P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make.-do- Long body, 15 mm nominal bore weight not less than 690 gm.B628(S-232/2.7.4) 49 P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Gyser etc. C.P. Inlet connection 15 mm Brass (IS:8931 marked).(S-233/2.12.1) 50 P & F Ball Cock ( IS : 1703 Mark) with Rod & P.V.C. Ball complete: Brass wt. 400 gm., 15mm.(S-232/2.11.1) 51 P & F Full-way Value (IS: 778 Mark) or wheet valve of approved make.Gun - metal 15 mm nominal bore.(S-233/2.15.1) 52 P & F Full-way Value (IS: 778 Mark) or wheet valve of approved make.Gun - metal 25 mm nominal bore.(S-233/2.15.3) 53 P & F PVC Storege Tank (IS : 12701 marked indicating the BIS license No.), of approved make with cover, 25 mm dia 1 M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design:500 ltr. capacity (S-236/2.26.3) 54 P&F towel rail or ring of appd quality or make Cp brass towel rail with bracket 600X20 mm heavy duty. (S-223/ 1.47.4) 55 P & F UPVC SWR. pipes grade B for sciland wast discharge system (IS :13592-1992 marked) of approved make75 mm dia (S-257/3.44.1) 56 P & F UPVC SWR. pipes grade B for sciland wast discharge system (IS :13592-1992 marked) of approved make 110 mm dia coupler (S-257/3.45.1(ii) ) 57 P & F UPVC SWR. pipes grade B for sciland wast discharge system (IS :13592-1992 marked) of approved make 110 mm dia bend (S-257/3.45.4 ) 87.5 degree 58 P & F UPVC SWR. pipes grade B for sciland wast discharge system (IS :13592-1992 marked) of approved make110 mm dia cowel (S-259/ 3.45.30) 59 P & F UPVC SWR. pipes grade B for sciland wast discharge system (IS :13592-1992 marked) of approved make110 mm dia Tee with door( S-258/3.45.17) 60 P & F Flush Cock/Flush Valve (IS: 9758 Mark) for WC of approved quality make: Brass / Gun metel Half-turn wt. 1 kg. of approved quality/ make, 25 mm nominal bore (S-233/2.14.9) 61 P & F 15 mm. Dia Connection Pipe of approved quality/make:PVC pipe with C.P. Brass nuts upto length. 450 mm.(S-233/2.13.3) 62 P & F Ist quality WVC Urinal (IS:2556 mark) with 25 mm dia G.I. waste pipe, dome couplings, concealed iron brackets or screws etc. complete.Flat Back (small) size 440x265x315 mm.(S-227/1.69.1) 63 P & F European type white glazed vitreous china Ist quality W.C. pan (IS:2556 Mark) with P or S trap including cutting and making good the wall and floor.(S-217/1.3) 64 P&F water closet seat covers with brass hinges complete Solid PVC [ISI marked] grade-1 white for EWC (S-232/1.7.1) 65 P & F Marble Urinal Partition slab both sides polished of approved design cut from marble size 900x600mm.Makrana Adanga or Raj Nagar IStQuality White or Andhi Indi-Italian marble.(S-234/1.16.3) 66 P&F Jet spray for water closet with C.P. copper tube flange of approved make(S-226/1.59) 67 Construction of septic Tank in all types of soil with 40 Cm .thick masonry in CM 1:6, 15 Cm thick C.C bed of 1:5:10, M-15 gradeC.C floor &RCC slab covering with M15 grade c.c. floor,50 mm thick stone slab partition walls, 20 mm thick plaster in CM 1:6 finished with neat floating cement, 4 Nos stone foot rests of approved design ,two No. 450 mm dia each Ferro cementcover with frame, earth work etc. complete as per approved drawing including disposal of surplus earth within a lead of 50 mtr:- Size 200x100x130 cm.(for 10 users) with 115 mm thick RCC (M-20) slab with Tor steel reinforcement 8mm ϕ @15 cm c/c bothways including shuttering complete in all respectS3.27.1 68 Construction of soakage well in all type of soil 300mm thick dry masonry, top and bottom 300mm course in CM 1:6, 80mm thick stone slab, jointing of slab in CM 1:3, Ralthal, Kharanja, 40mm thick M-15 grade C.C. flooring, earthwork complete as per approved drawing including disposal of earth within a lead of 50 mtr. : Size 240 cm. dia outside & 240 Cm. Depth. (S-252/3.22.3) 69 Construction of manhole in all type of soil inner size 90x60 cm. thick masonary in CM 1:6, 10 Cm. thick cement concrete 1:5 10 in foundation, 20mm thick inside plaster in CM 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring making channels, 80mm thick stone slab covering with 40 mm thick M-15 grade C.C. flooring, RCC cover with frame of 450mm dia, earthwork etc. complete as per design including disposal of surplus earth within 50mtr. lead. Depth up to 0.5 M (S-250/3.19.1) 70 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR E-1.1 (A) short poing (upt 3 mtr.) (1.1.1) 71 (B) Medium point (Upto 6.0 Mtr.)(1.1.2) 72 (C) Long point (Upto to 10.0 Mtr.)(1.1.3) 73 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR On board E- 1.3.1 74 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR2 x 2.5 sq. mm. + 1x1.5sqmm E- 4.1.7 75 (B) 2x4.0 sq. mm + 1x 2.5 sq mm ( E-4.1.14) 76 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure A attached with this BSR E-7.37 77 P & F paper phenolic resin bondedlaminates confirming to IS : 2036 -1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc platednut and bolts as required. For additional technical parameters of product / work refer Annexure A attached with this BSR4.8 mm thick E- 5.5.2 78 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR E- 5.9 79 Providing & Fixing of IP65 IK08 rated Integrated SMD Mid power LED bulk head type light fixture made from Pressure Die Cast AL housing suitable with integral driver, system lumen efficacy ≥100 lm/Watt output , THD < 10% ,p.f.≥0.95,CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. surge protection 4 KV. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Minimum lumen output 1000 lm (E- 89/17.6.1) 80 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR Single pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating (E-17/6.1.1.2) 81 Providing & Fixing of 240/415 V isolatorISI marked IS:13947-III/conforming to IEC 60947-3, suitable for AC22A utilization category, 4KV impulse withstand voltage,true contact indication,Red colour dolly / lever shall have single mould covering over all poles for operation , two position din rail mounting,minimum phase termination capacity of 35sq.mm.IP 20 contact protection and fitted in existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR Double pole isolator 30 A / 40 A rating (E-18/6.2.1.1) 82 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRMetal door (single phase) IK-09 and IP-43 with Metal end box8 Way (8+2)E-6.10.1.3 83 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR5 step fan regulator 2 Module 360 dgree rotating E- 7.29.1 84 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .1200 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5 ) E- 15.7.3 85 Providing & Fixing ofof BLDC Technologyventilating fans , single phase with PVC impeller, ABS body, Double Ball bearing, automatic back lower shutterincluding making connection, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 250 MM sweep (E 15.5.3) 86 Providing & Fixing of energy efficient direct fit (Retrofit)Polycarbonate/ GlasshousingSMD Mid Power LED tube rod(with integral driver & alumn. heat sink ), on existing fixture.system lumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.≥0.95,CRI >80 , life time of minimum35000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .1200mm , Min. Lumens output 2000 lmLED Tube rod with Polycarbonate Housing E- 17.2.2 87 Providing & Fixing of IP20, 2x2 LED Surface/ Recessedmounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 ,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Surface MoutningMinimum lumen output 3000 lmE17.4.2.1 88 Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete.Rajasthan BlackAbove 3601 Cm2 SlabsB-84/7.5.6(iii) 89 Earth work in excavation, including stacking / disposal of surpulus material with all lifts and lead upto 50mtr exclusive of compensation of earth [MoRTH specifications :clause 301 to 305]in ordibnary soil Kassi work undressed , involving an average horizontal through upto 2 mtr and an average vertical lift upto 0.5mtr including breaking of clods .(R 8/3.1.1.1) 90 Providing and Laying cement concrete Kerb Stones of different sizes in M-30 grade (Manufactured with fully mechanised dry cast process with forced action mixer whose arms revolve along the main axis and rotate about its own axis also, having humidity sensor for moisture control of w/c ratio in concrete mix. Manufactured with steel moulds (Milled and manufactured in CSI diamond or CSI Nitro process for accuracy) on steel base plate of min 16 mm thick;Having Vibration and pressing action both together withthe help of multiple synchronised vibrators.Power of hydraulic station should be minimum 50KW for compaction and cured in controlled chambers having humidity control and automated air circulation system) in position to the required line, level and curvature jointed with cement mortar 1:3 (1 Cement : 3 Coarse sand) including making of joints, drainage opening wherever required.Size1000x450x150.B17.21 91 Carraige of Earth, sand, lime, morrum manure or sludge Upto 15 KmG-4.1 92 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR E- 1.4.2 93 Finishing wall with water proofing cement paint of approved brand and manufacture and or required shadetogive an even shade including all scaffolding:New work (Two or more coats applied @ 3.84 kg/10 sqm).(B-145/12.41.1)
Contract Date : Ref. Documents   |   Contract Value : Ref. Documents
BRR : 6702934 Providing Modern Kitchen With Equipments, Girls Room With Toilet Facilities And Painting Works In Dormitories For Government Observation Home At Salem In Salem District-Earth work excavation for foundation (for narrow excavation) in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by thedepartmental officers with an initial lead of 10 mts and initial lift of 2 mts. and clearing and levelling the site, etc., complete complying with standard specification. 2 Cement Concrete 1:5:10 (One Cement, Five crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundationincluding dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification 3 Supplying and filling in foundation, basement, etc with filling crushed stone sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. 4 Supplying andFILLING GRAVEL Supplying and filling in foundation andbasement with filling crushed stone sand in layers of not more than 15cm.thick well rammed watered and compacted -1m3 etc., complete complying with standard specification. 5 Refilling with excavated earth other than crushed stone sand with an initial head load of 100 mts. and depositing the earth as shown by the departmental officersin layers of not more than 15 cm thick well rammed, watered and consolidated etc. complete complying with standard specification 6 Cement Concrete 1:5:10 (One Cement, Five crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for flooring including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification 7 Brickwork using Fly Ash bricks of size 230mmx110mmx70mm virtually the bricks shall be sound compact and uniform in shape free from visible cracks, warpage flaws and organic matter. The bricks shall be solid with frog on one of its bearing side. Class designationnot less than 35 kg/sq. cm an average compressive strength in Cement Mortar 1:3 - (One Cement and three crushed stone sand) including neat finishing, curing etc., complete complying with standard specifications.-For Foundation and basement 8 Brickwork using Fly Ash bricks of size 230mmx110mmx70mm virtually the bricks shall be sound compact and uniform in shape free from visible cracks, warpage flaws and organic matter. The bricks shall be solid with frog on one of its bearing side. Class designationnot less than 35 kg/sq. cm an average compressive strength in Cement Mortar 1:5 - (One Cement and five crushed stone sand) including neat finishing, curing etc., complete complying with standard specifications.-For Foundation and basement 9 Brickwork using Fly Ash bricks of size 230mmx110mmx70mm virtually the bricks shall be sound compact and uniform in shape free from visible cracks warpage flaws and organic matter. The bricks shall be solid with frog on one of its bearing side. Class designationnot less than 35 kg/sq. cm an average compressive strength in Cement Mortar 1:6 - One Cement and six crushed stone sand - including neat finishing, curing etc., complete complying with standard specifications. 10 For Super structure in Ground Floor 11 For Super structure in First Floor 12 For Super structure in Second Floor 13 Brick partition walls of 11.50cm thickness using best quality Fly ash bricks of size 23x11x7cm in Cement Mortar 1:3 (One Cement and Three crushed stone Sand) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately) 14 For Super structure in Ground Floor 15 For Super structure in First Floor 16 Damp proof course with Cement Mortar 1:4 (One Cement and Four crushed stone sand) 12mm thick mixed with best approved quality water proofing compound conforming to Indian Standard specification as specified by the departmental officers at 2% by weight of cement used, finishing and curing etc. complete complying with standard specification. 17 Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oakjoists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid) 18 Supplying and Erecting, Steel Centering for sides and soffits including supports and strutting upto 3.29m height for plane surfaces as detailed below in all floors with all cross bracings using mild steel sheets of size 90cmX60cm andBG 10 gauge stiffened with welded mild steel angles of size 25mmX25mmX3mm for boarding laidover silver oak joists of size 10cmX6.50cm spaced at about 90cm centre to centre and supported by Casurinaprops of 10cm to 13cm dia spaced at not less than 75cm centre to centre at sutiable intervals etc., complete in all floors as directed by the departmental officers complying with standard specifications.The payment for centering shall be made only after the concrete laid.The retrieved materials should be taken back by the contractor.- 19 Plane surfaces such as RCC floor slab, roof slab, rectangular, square, Tee or Ell beam, lintels, bed blocks staircase waist slab, landing slab, landing beams, portico beams, portico slab etc., 20 For plane surfaces such asrectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc. 21 Providing additional strutting to centering of RCC slabs of plain surface for every additional 1.0 metre height or part thereof but not less than 30 cm, over the initial 3.00 metre height from floor level using casurina props of 10cm to 13cm dia including cross bracing etc., complete complying with standard specification and as directed by the department officers. 22 Providing and laying in position, standardised concrete Mix M.20 Grade in accordance with IS:456-2000, using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m.) 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials). 23 For Foundation and Basement 24 For Super structure in Ground Floor 25 For Super structure in First Floor 26 For Super structure in Second Floor 27 Cement Concrete 1:3:6 (One Cement, Three crushed stone sand and Six broken stone jelly) using 40mm size hard broken stone jelly for dummy columns, excluding cost of centering shuttering reinforcement grills and fabrication charges but including curing etc. complete. (Reinforced Cement Concrete 1:2:4 for slab to be extended upto top of splashing with pressed tiles and future extension rods to be embedded in CC 1:3:6 (One Cement, Three crushed stone sandand Six hard broken stone jelly).Dummy columns should be at least 1 metre height) 28 Manufacturing, supplying and fixing Precast Reinforced Cement Concrete slabs of following thickness in RCC 1:2:4 (one cement, two crushed stone sand and four aggregates), using following HBGS jelly excluding cost of reinforcement steel in position but including cost of moulding charges, casting of slab, finishing, curing and fixing in position in all floors etc., complete complying with standard specification and as directed. 50mm thick slab (using 20mm HBGS Jelly) 29 Supplying, fabricating and placing in position Mild steel or Ribbed tor steel in all size for all RCC works as per the design given including cost of steel and binding wire in all floors etc., complete complying with standard specifications.(The contratctor will have to make his own arrangements for the supply of MS plain rod / RTS rod and binding wire) 30 Plain Cement Concrete 1:2:4 (one cement, two crushed stone sand and four hard broken stone jelly) using 20mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the departmental officers 31 Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no crushed stone sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers. 32 For Superstructure in First floor 33 For Superstructure in second floor 34 For Superstructure in third floor 35 Finishing the top of roof with one course of machine pressed tiles of size230mm x 230mm x 20mmapproved quality set in Cement Mortar 1:3 (One Cement and Three crushed stone Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers 36 Paving the floor with best quality Double charged Vertified Tiles of size 800 x 800 x 10mmof approved colour, shade and quality laid in cement mortar 1:3 (one cement and three crushed stone sand) 20mm thick in all floors and the top pointed with the white cement mixed same colour pigments etc., complete complying with standard specification.(The make and brand of the tiles should be got approved by Executive Engineer before use on works) 37 Paving the floor with best approved quality fine polished Kota stone slabs of size below 600 x 600 of 18 / 20mm with machine cut edges and matching marble slab not less than 100mm width other than Adanga Marbles as border laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and threecrushed stonesand) fixing the slabs in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments and polishing with floor polisher to a high degree of finish etc., The kota stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification. 38 Flooring with following ceramic tiles of size 305 x 305 x 6 mm laid over 20 mm thick cement mortar 1:3 (One Cement and Three Sand)base mortar over the existing slab / floor including cutting the tiles to the required size with special cutter wherever necessary, laying in position with 4mm Spacer, Pointing and filling the tile joint with epoxy grout with following specification. Surface preparation including cleaning the joint to be free from dust and loose particles. Providing masking tape on either side of the tile joint edges and providing sealing the tile gap with epoxy tile joint grout and finishing neatly and as directed by the departmental officers. The rate inclusive of cost of materials and labour, etc., complete.complying with standard specification.(The make and brand of the tiles should be got approved by Executive Engineer before use on works) 39 Dadooing ceramic tiles of size 300x600x10mm best approved quality, white / colour glazed tiles of following sizes set in Cement Mortar 1:2 (One Cement and Two crushed stone sand) 10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. neatly in all floors, curing, etc., complying with standard specification and as directed by the departmental officers. 40 Paving the floor with pre-polished concrete anti-skid tiles (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three crushed stone sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by Executive Engineer before use on works) 41 Providing Polymer Coating (Water Proof Coating) for sunken Portion of toilet with following specification and the surface shall be cleaned to remove all dust, foreign, matters lose materials or any other deposits of contamination by rubbing with wire brush. Slurry: Dry blend and polymer liquid blend shall be mixed into the desired ratio as per recommendation of the supplier. The mix shall be stirred throughly until no bubbles remain in the mix. Any lumps found in mix shall be removed. Apply first coat of polymer modified cementitious slurry by brush on wet cleaned surface. After drying, second coat shall be applied on the first coat as directed by the departmental officers etc. The rate inclusive of cost of materials and labour, etc., complete. 42 Supplying and fixing in position best approved BIS quality PVC Rainwater Downfall pipes of 160mm dia having working pressure of 4kg/cm2 including cost of PVC pipe, with necessary shoes, bends, nails, teakwood plugs, screws etc, and fixing of cast iron gratings of required dia metre and special clamps at junction of parapet and the RCC roof slab including finshing neatly etc., complete.The rate shall be inclusive of costof removable cast iron gratings. The size of teak wood plugs to be used shall be 150mm x 25mmin front and200mm x 75mm in rear and all other sides to a depth of 100mm.The PVC pipe shall be fixed with teakwoodplugs by means of U Clamps using brass screws. Special types of U clamp at the centre of the pipeline shall be fixed in addition to those for more than 3 metre pipe length complying with standard specifications.-One Floors 43 Solid PVC door shutters using 19 Gauge 19mm MS square tubes for styles and outer frames.15mm MS square tubes for top, lock and bottom rails.The steel tubes shall be covered with 5mm thick solid PVC sheets.Shutter using 5mm thick solid PVC sheets for panelling shall rigidly fixed in position including necessary furniture and fittings. The over all size of styles shall be 50mm x 30mm.The over all size of top rail,Lock rail and bottom rail shall be 75mm x 30mm. The over all size of frames shall be 50mm x 45mm, with suitable rabate for housing the shutter. (Solid Panel PVC Door with frame) 44 Fabricating, Supplying and fixing in position of steel sheeted windows (Two Leaves) with the following specifications. Outer frames of windows made of Z section F7D of size 33 x 25 x 3mm at 1.419 kg/ m and mullion J section (F4B) of size 46x25x3mm at 2.28kg/m and shutter section of made ofF7D of 33x25x3mm at 1.419 kg/m as specified in IS 7452/1990. Each openable shutter should not exceed a width of 600mm to enable separate operations and easy maintenance. The panel of the shutters to be covered with 18 gauge cold rolled sheet of superior quality and welded intact with shutter frames. Horizontal stiffeners using 18x5mm MS Flat at 0.70kg/m at 3 Nos. for each shutter and additional diagonal stiffners of the same MS flats at all the four corners of each shutters to the suitable length welded to the shutters, for holding the CR Sheets in position firmly. 2 numbers of sturdy hinges and one number of handle-cum-latch of special type made with 18x5mm MS flats are revetted to the shutters at an appropriate height in window. suitable opening is left for its easy operation. a stopper square rod for handle is provided in the mullion section at suitable place to catch the window handle. each window shutter having an adjustable stay made out of 18 x 5mm at 0.70 kg/ m MS flat of lengt320mm with three adjustable position. A matching peg is provided in the outer frame of the window at suitable place. 4 Nos. of hold fasts of 120mm length spliced at the ends are welded to the outer frame of the window by using MS flat of 18x5mm at 0.70kg/m, welded to the shutter at two place equivalent from each from top and bottom of the shutter. An MS square bar of 12mm size is welded to the inner face of the window at an equal interval not exceeding 100mm edge between them. All members are painted with one coat of anti-corrosive red oxide primer as directed by the departmental officers. All sections should be in confirmed with IS 7452/1990.The cost includes cost of all materials, labour charges and other incidental charges, etc., complete 45 Fabricating, Supplying and fixing in position of steel sheeted windows (Three Leaves)with the following specifications. Outer frames of windows made of Z section F7D of size 33 x 25 x 3mm at 1.419 kg/ m and mullion J section (F4B) of size 46x25x3mm at 2.28kg/m and shutter section of made ofF7D of 33x25x3mm at 1.419 kg/m as specified in IS 7452/1990. Each openable shutter should not exceed a width of 600mm to enable separate operations and easy maintenance. The panel of the shutters to be covered with 18 gauge cold rolled sheet of superior quality and welded intact with shutter frames. Horizontal stiffeners using 18x5mm MS Flat at 0.70kg/m at 3 Nos. for each shutter and additional diagonal stiffners of the same MS flats at all the four corners of each shutters to the suitable length welded to the shutters, for holding the CR Sheets in position firmly.2 numbers of sturdy hinges and one number of handle-cum-latch of special type made with 18x5mm MS flats are revetted to the shutters at an appropriate height in window. suitable opening is left for its easy operation. a stopper square rod for handle is provided in the mullion section at suitable place to catch the window handle. each window shutter having an adjustable stay made out of 18 x 5mm at 0.70 kg/ m MS flat of length 320mm with three adjustable position. A matching peg is provided in the outer frame of the window at suitable place. 4 Nos. of hold fasts of 120mm length spliced at the ends are welded to the outer frame of the window by using MS flat of 18x5mm at 0.70kg/m, welded to the shutter at two place equivalent from each from top and bottom of the shutter. An MS square bar of 12mm size is welded to the inner face of the window at an equal interval not exceeding 100mm edge between them. All members are painted with one coat of anti-corrosive red oxide primer as directed by the departmental officers. All sections should be in confirmed with IS 7452/1990.The cost includes cost of all materials, labour charges and other incidental charges, etc., complete 46 Supplying and fixing in position Glazed steel ventilator with Side/Central hung shutters( Two Leaves) frames and made shutter frame made out of steel section conforming to IS 7452 /1990.The outer frame made out of z section (F7D) of size 33 x22 x3 mm conforming to IS 7452/1990.The mullions are made out of (F4B) section of size 46x25x3 mm and conforming to IS7452/1990.The shutters are individual and each of them can be operated separately. Sash bars are made of T section (T2) of size 25 x 22 x 3mm 2 nos of sturdy hinges and one number of handle cum latch of special type are fixed are each openable shutter withsuitable opening in left for its easy operation, one member ofadjustable strings with fixing brackets of sufficient length are provided for each shutter 4 nos of40 x 40 x 3 mmangle hold fast 230mm length are welded with the frame at appropriate point M.S Square bars of 12 mm dia is weldedto the inner face of the ventilator at equal intervals not exceeding 10 cm spacing 3mm pin headed glass is used for Glazing with good quality and fixed with 15 x 12 mm teak wood beadings with screws for fixing .The shutters are to open outside. All the section are given with one coat of red oxide primer etc. complete complying with standard specification. The sample of materials and fittings shall be got approved by the departmental officers before use on work. ( The rate shall inclusive of cost all materials labour charges one coat of primer, weld charges, including cost of welding electrodes, transportation to site work, loading, unloading and incidental charges etc., complete complying with standard specification. 47 Manufacturing supplying and fixing of steel door with the following specification MS angels of size 40x40x6mm are used for the outer frames and M.S. angles of size 35x35x5mm for the shutter frames stiffeners with 32 x 6mm M.S flat is provided at required intervals in the shutter frame. 18-gauge C.R. sheet laid as panel in the shutter and welded intact. M.S. flat 18x5mm is welded over the 32 x 6mm M.S. flat sandwitching the C.R. sheet in between additional stiffeners with 18x5mm M.S. flat is provided diagonally at the rear side of the shutter, 3nos. of hinges in case of single leaf and 6nos. of hinges in double leaves shutter to be provided 6nos. of holdfasts 120 mm in length made of angle section spliced at the ends are welded to the outer frames of the door. Tower bolts 2nos. one at the top and the other at the bottom are provided 1no. Aldrop is provided incase of double leaf door at lock rail section in the door in single leaf door, one more aldrop is provided in the inner lock rail section of the door One rotaing locking arrangements for the inner side of the door and additional provision for locking arrangements for lock is provided on the rear side of the door at an appropriate place.Incase of double leaf door M.S.Flat 32 x 3mm at 1.1Kg/m is provided on the one shutter t conceal the gap between the two shutters.at an appropriate place in the door. A tie bar is provided at the bottom of the frame to prevent twisting of frame during transportation and fixing. All members are given a coat of red oxide primer as directed by the departmental officers. The rate includes cost of all materials, labour charges, transportation to site of work, loading, un loading and all other incidental charges etc., complete. 48 Single leaf 49 Double leaves 50 Supplying and fixing in position steel balustrades using 20mm square rods spaced at 150mm centre to centre so that the two balustrades in each step shall be placed centrally and the top of balustrades connected with the hand rails (cost of hand rail shall be measured and paid separately) by means of MS flats of size 40mm x 6mm in the groove 40mm x 6mm provided at the bottom of hand rail; the bottom of balustrades shall be fixed on to the top of step concrete.An additional MS flat of size 50mm x 6mm shall be provided at the centre of balustrades connecting all square rods to the entire length including cost of square rods, flat and applying one coat of red oxide primer to the iron surfaces, etc., complete complying with standard specification and as directed by the departmental officers. 51 Supplying and fixing 40mm dia GI pipe for staircase hand rail including labour charges for cutting, welding and fixing with MS flats (excluding cost of flat), etc., as directed by the departmental officers 52 Supplying, and fixing M.S. GRILLS for open courtyard grill, grill work to doors, windows and ventilators etc, using necessary flats for inner and outer members which should be fixed or welded to masonry or column including necessary dismantling or making holes and redoing the same to original condition as directed by the departmenta officers inclusive of cost of providing one coat of best quality red oxide primer completre complying with standard specifications. 53 Supplying and fixing fine polished cuddapah slab of 38/40mm thickness for cup-board arrangements including laying to correct alignment with necessary cement mortar and black powder etc, complete complying with standard specification and as direct.25mm thick 54 Providing Cup-board Shutter with frame using termite / water proof plywood of 19mm thick over which laminated sheet of 0.8mm thick fixed inside the shutter and 1mm thick fixed in the outside of the shutter using fevicol along with necessary furniture fittings, such as, hydralic hinges, tower bolt, handles, multi purpose locks etc., as directed by the Departmental Officers. The design pattern, water proof plywood, laminate sheet and other materials should be got approved from the Executive Engineer befoe use on work. 55 Plastering with Cement Mortar 1:5 (One cement and Five P.sand), 12mm thick mixed with Bonding agent Cebex112, Zydex -Zycrete 2X or other Equalent compound conforming to BIS at 200ml of One cement bag (50kg) for increased workability and air entrainment used finishing in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers. 56 Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three P.Sand) 10mm thick mixed with Bonding agent Cebex112, Zydex -Zycrete 2X or other Equalent compound conforming to BIS at 200ml of One cement bag (50kg) for increased workability and air entrainment used finishing including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the departmental officers 57 Plastering the surface of walls with Cement Mortar 1:3 (One cement and Three P.sand), 12mm thick mixed with water proofing compound conforming to BIS at 2% by weight of cement and with Bonding agent Cebex112, Zydex -Zycrete 2X or other Equalent compound conforming to BIS at 200ml of One cement bag (50kg) for increased workability and air entrainment used finishing in all floors including curing etc., complete complying with standard specification and as directed by the departmental officers. 58 Supplying and applying of two coats of putty of 3mm thick over the exposed RCC surface of ceiling including finishing the joints smoothly with grinding machine and the surface shall be thoroughly cleaned out of dust and scrubbing. The surface shall then be allowed to dry for atleast 48 hours. It shall then bel sand papered (waterproof abrasive sheet) to give a smooth and even surface. Any unevenness shall be made good by applying 1st coat of putty mixed with water on the entire surface including filling up the undulations and applying 2nd coat of putty after 6 hours of 1st coat of putty and then sand papering (waterproof abrasive sheet) the same after it is dry and finishing the surface smoothly, etc., complete complying with standard specifications and as directed by the Departmental Officers. [The rates are inclusive of hire charges for grinding machine with wheel, cost of sand paper (waterproof abrasive sheet), cost of putty blade, labour charges for grinding the joints and sand papering, two coats of putty, scrapping the putty area to level the surface smooth, etc., complete]. The putty should be got approved by the Executive Engineer before use on work. 59 Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification. 60 Painting the wall two coats with approved weather proof Exterior Emulsion paint over one primer coat of over cement plastered wall surface ect., completecomplying with standard specification. 61 Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) 62 Supplying, laying and jointing 25mm dia CPVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing CPVC specials using CPVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, CPVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications.The CPVC pipes shall be got approved by Executive Engineer before use on works. 63 Supplying CPVC Specials (with working pressure 10 kg. / sq.cm.) in water supply arrangements , Since the labour for cutting, threading / pasting, sundries have already been included under pipe line item of works, no separate provision for fixing CPVC specials needs to be allowed(both in internal and external water supply arrangements 64 25 mm dia CPVC Elbow 65 25 mm dia CPVC TEE 66 25 mm dia CPVC Union 67 25 mm dia UPVC Nipple 68 Supplying, laying and jointing UPVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing UPVC specials using UPVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications.The PVC pipes shall be got approved by Executive Engineer before use on works.Internal Water Supply Arrangements using UPVC pipes and UPVC specials 69 25 mm dia UPVC Pipe 70 32 mm dia UPVC Pipe 71 40 mm dia UPVC Pipe 72 50 mm dia UPVC Pipe 73 Supplying UPVC Specials (with working pressure 10 kg. / sq.cm.) in water supply arrangements (both in internal and external water supply arrangements 74 25 mm dia union 75 32 mm dia union 76 40 mm dia union 77 50 mm dia union 78 25 mm dia Elbow 79 32 mm dia Elbow 80 40 mm diaElbow 81 50 mm diaElbow 82 25 mm diaTee 83 32 mm diaTee 84 40 mm dia Tee 85 50 mm dia Tee 86 32 x 25 mm dia Reducer 87 25 x 20 mm dia Reducer 88 20 x 15 mm dia Reducer 89 Supplying and fixing in position first quality and approved variety of Gun metal Gate Valve with BIS make of the following dia including cost of shellac, thread balls, etc., complete complying with standard specifications (for both internal and external water supply arrangements).The valves to be used on work shall be got approved by the Executive Engineer before use on work. 90 25 mm dia G.M. Gate Valve 91 32 mm dia G.M. Gate Valve 92 40 mm dia G.M. Gate Valve 93 50 mm dia G.M. Gate Valve 94 Supplying and fixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm colour glazed earthern ware of approved quality and brand with P or S trap conforming to BIS with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two sand and Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to PVC pipes (including the cost of 110mm dia PVC pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers.(The water closet should be got approved by the Executive Engineer before use on works). 95 Supplying and fixing in position white / colour glazed European Water Closet of best quality and approved make with 100 mm P or S trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC flushing tank with a pair of CI brackets, etc., complete with all fittings such as 15mm brass ball valve with polythene float with brass handle, union, coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittings.....such as 15mm brass connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe including cost of 600mm length of 110mm dia PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition etc. complete complying with standard specifications.(The EWC and flushing tank wiht all accessories should be got approved by the Executive Enginer before use on works) 96 Supply and fixing in position of best Indian make white / colour glazed earthernware lipped mouth flat back urinal of best quality and approved make of size 430mm x 260mm x 350mm with GI pipe, 32mm dia bell mouth PVC connection and waste pipe, 15mm dia GI pipe of required length, 15mm dia GM wheel valve, 15mm dia brass nipple 2 Nos., and fixing the urinals in position with necessary TW plugs, clamps, screws, etc., including dismantling masnory and re-doing the same to the original condition, etc., including painting the pipe with two coats of best quality approved synthetic enamel paint over one coat of red oxide primer and checked without any leakage etc. complete complying with standard specifications and as directed by the departmental officers.(The urinal should be got approved by the Executive Engineer before use on works.) 97 Supplying and fixing in position best quality and approved make Indian made white / colour glazed earthernware wash hand basin of size 550 x 400mm (without pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia B class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. 98 Supplying and fixing of Granite Sink of size 600 x 600 x 250mm including cost of 32mm dia CP waste coupling, 32mm dia PVC waste pipe with rubber plug and chain, 15mm dia brass nipple including fixing the sink in position and testing for leakages etc., complete complying with standard specifications excluding CI brackets.[The sink and specials should be got approved by the Executive Engineer before use on works] 99 Supplying and fixing in position Indian make bevelled edge mirror of approved quality and brand PVC / Fibre Glass framed 600 x 450 x 5.5mm thick mirror, shelf type with hard board backing of approved colour fixed with brass screws, rawl plug, etc., complete complying with standard specification 100 Supplying and fixing best approved best quality brass CP soap tray of size 150 x 150mm including cost of teak wood plugs, brass screws, etc., complete complying with standard specifications. 101 Supplying and fixing approved best quality brass CP towel rail 600mm long and 20mm dia with brackets of same materials including cost of teak wood plugs and CP screws, etc., complete complying with standard specifications. 102 Supplying and fixing in position CP shower rose with CP stop cock arrangement of size 15mm dia inlet and 100mm outlet to the pipe line with necessary cutting, threading and jointing using shellac etc., complete complying with standard specification and as directed by the departmental officers 103 Supplying and fixing in position 15mm dia brass CP screw down tap / Pillar tap (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary.(Taps should be got approved by the Executive Engineer before use on the works) 104 Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications.(The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level 105 75mm dia PVC soil / waste pipe 106 110mm dia PVC soil / waste pipe 107 160mm dia PVC soil / waste pipe 108 Supplying and fixing in position PVC specials of the following dia and types of approved quality confirming to BIS and providing leak proof joints including fixing to the walls and giving connection to the PVC soil stacks, dismantling the masonry or RCC works and re-doing the dismantled portion to original condition etc., complete complying with standard specifications. (The PVC specials should be got approved by the Executive Engineer before use on works). 109 75mm dia PVC Elbow 110 75mm dia PVC Tee 111 75mm dia PVC Tee with single door 112 75mm dia PVC Bend 113 110mm dia PVC Elbow 114 110mm dia PVC Tee 115 110mm dia PVC Tee with single door 116 110mm dia PVC Bend 117 Supplying and fixing position PVC Nahani Trap / Floor Trap of the 100 x 75mm with PVC gratings sizes with best stainless steel gratings of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (One part of lime, two part of sand and five part of 40mm gauge brick jelly) and finished with Cement Mortar 1:3 (One Cement, Three sand) including dismantling masonry works wherever found necessary and making good the dismantled portions to the original condition and giving connection to thePVC pipes, etc., complete complying with standard specification. 118 Supplying and erecting 1 H.P monoblock with ISI mark with necessary accessories (motor should be got approved by Executive Engineer before use onworks) complete complying with standard specification. 119 Supplying and erecting 1000lit PVC tank with ISI mark with necessary accessories (motor should be got approved by Executive Engineer before use on works) complete complying with standard specification. 120 Supply and fixing of windows Screens using superior quality of cloth as Specified by the departmental officers including cost of cloth, labour charges for stitching charges to the required size and shape with necessary hooks, cutting and top Stainless steel rods of ornamental design, fixing with necessary plugs and screws etc., complete complying with standard specification. 121 Preconstruction Antitermite treatment for the Construction of building all chemicals as per standard specification including labour charges for preparing the area for treatment spraying chemicals and other incidental charges et., complete. The rate follwing four stages including breaking the termite mounds making holes with cowbras and pouring chemicals etc., complete as per IS 6313 - 1981 and as directed by the depatrmental officers etc., complete including cost of chemicals labour transport storing etc., The termite chemicals should have 0.5% concentration for entire operation 122 White washing two coats wth freshly burnt white shell lime in all floors including cost of lime, blue powder fevicol type gum, brushes, scaffolding charges, etc., complete complying with standard specification and as directed. 123 Painting the old wall Surface two coats with approved weather proof Exterior Emulsion paint over one primer coat of over cement plastered wall surface ect., completecomplying with standard specification. 124 Painting old wood work with two finishing coats of synthetic enamel ready mixed paint of approved quality and colour over one coat priming coat in all floors including the cost of primer etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) 125 Painting Old iron works Two Coatssuch as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over one coat of red oxide priming coat in all floors including cost of priming coat etc., complete complying with standard specification. 126 GST
Contract Date : 23 Jan, 2025   |   Contract Value : 65.87 Lakhs
BRR : 9250947 Creation Of Manned Submersible Experience Centre At National Institute Of Ocean Technology, Niot Campus, Pallikaranai, Chennai , Pre Construction Works Dismantling Of All Paver Blocks Including Stacking Of Serviceable Material As Directed By The Engineer In Charge,And Disposal Of Unserviceable Materialsoutside Site Premises , Earthwork Excavation By Mechanical Means Using Jcb, Poclain,Etc., For Foundations, Footing, Rafts, Plinths, Pools, Under Ground Structures, Etc. In All Types Of Soil Including Dense, Wet Or Dry (Such As Yellow, Murrum, Hard Murrum/Gravel Or Mixture Of Any Kind), In Loose And Slushy Condition, Including Leveling, All Leads And Lifts, Rate To Include Stacking Within The Site Adjacent Plot Wherever Specified And Spreading In Layers To The Required Levels And Disposing The Excess Earth By Carting Away Out Side The Site To The Designated Areas Identified By The Local Authorities. Rate Is Inclusive Of Making Temporary Stepping/ Sloping, Shoring With Planking, Strutting, Sectioning, Trimming, Dressing Of Sides, Leveling Or Grading, Cleaning, Removing And Excavating Loose Pockets And Consolidating Them By Backfilling As Directed, Dewatering Of Surface Water Including Rain Water, Removal Of Slurry Generated While Excavation And Keeping The Area Free Of Water, Excavating Loose Pockets And Compacting The Same. Note: Authorised Working Space If Required Shall Be Considered As Per Is 1200. (Provision Of Slopes If Required For Execution).Excavation Upto 1.50M , Back Filling Available Excavated Earth To Excavated Areas In Layers Of 150Mm With Watering And Compaction. Rate Is Inclusive Of Making Temporary Stepping/ Sloping, Shoring With Planking, Strutting, Dressing Up Embankments: If Required, Bailing/ Pumping Out Of Water To Keep Site Dry While Back Filling; Costs Includes Conveyance Of All Materials, Labour, Machinery Etc. Complete Directed. Note: Authorised Working Space If Required Shall Be Considered As Per Is 1200. , Filling And Banking Approved With Good Quality Earth In Plinths, Basement, Areas Development Etc. Other Than The Back Filling Of Excavated Areas In Layers Not Exceeding 200Mm In Depth, Breaking Clods, Watering, Rolling Each Layer With Vibratory Compactor And At Inaccessible Places With Wooden/ Steel Rammers To Achieve 90 To 95% Proctor Density At Optimum Moisture Content; Dressing Up Embankments; If Required, Bailing/ Pumping Out Of Water To Keep Site Dry While Back Filling; Costs Includes Conveyance Of All Materials, Labour, Machinery Etc. Complete. Proctor Compaction Test To Done After Filling. , Supplying, Filling, Levelling, Watering And Consolidating With Approved Good Quality M-Sand In Layers Of Thickness 150Mm In Foundation & Flooring Of Any Depth Sides Of Foundation Etc., Including Loading, Transporting, Unloading , All Leads And Lifts, Labour, Ramming With Iron Or Wooden Rammers, The Surface Shall Be Flooded With Water For Minimum 24 Hours And Etc., All Complete As Directed. , Anti-Termite Treatment - Providingand Injecting Chemical Emulsion Chlorophyriphos 20 % Emulsifiable With Concentrates 1 % @ 5 Ltr. /Sqmof The Surface Or As Directed By Project Manager,For Pre-Constructional Anti -Termite Treatment And Creating A Continuous Chemical Barrier Under And Around The Column Pits, Wall Trenches, Basements Excavation, Top Surface Of Plinth Filling, Junction Of Wall And Floor Along The External Perimeter Of The Of The Building, Expansion Joints Over The Top Surface Of Consolidated Earth On Which Apron Is To Be Laid, Surroundings Of Pipes And Conduits Etc. Complete As Per Specifications. (Plinth Area Of Building At Ground Floor Only Shall Be Measured For Payment) , Piling Works Boringinallkindsofsoils(Asmetatsite)Gravelshingleetc. Includingwaterbearingstrata,Disposalofearthetc.Takenout Fromboresoutsidethesiteorasdirectedbysiteincharge, Excludingthecostofsteel Reinforcement Butincludingthecostofbentonitesolutionfor Bore Stabilisation Etc. By Using Pumps ( Capacity Minimum35 - 40 Hp) Prior To Placing Concrete, Disposal Of Bentnite Solution Etc As Directed All Complete (Length Of The Pile Shall Be Considered For Payment).Therateshallincludecostofalignmentoftwonos.Ofbarof Required Diameter Which Is To Be Used To Hold The Reinforcement Cage Vertical During Concreting, Making Slurry Vats At Pre Approvedlocationofsite,Usingbentonite,Removal&Shiftingof Bentonite Slurry, Solid, Semisolid Liquid Muck From Vat/Drain, Dry/Wet Soil Mixed With Bentonite And The Surplus Earth Excavated Fromvattooutsideofthesitepremisesbytanker&Other Transport. Piles Shall Be Cast As Per The Schedule Of Cut Off - Level Given In The Execution Drawing.Pile Driving 450 Mm Dia, 18 M Long. , Providing Andinstallingcastinsitureinforcedcementconcrete Pile Of Specified Dia Meter And Length Below The Pile Cap,In M-35 Cement Concrete - Ready Mixed Concrete, Design Mix With Minimumcement400kg/Cum(Useofflyashprohibited) Including Admixture As Approved By Engineer-In-Charge To Carry A Safeworkingloadnotlessthan40t. , R.Cc/P.C.C Works Providing And Laying Required Thickness Of Controlled Plain Cement Concrete Of Pcc 1:4:8 Grade Using Over 20Mm And Down Size Coarse Graded Hard Stone Aggregate For Levelling Course In Pile Cap And Flooring At Any Mass Concrete And Other Similar Works At All Levels And Heights, Elevations, Mechanical Mixing, Transporting And Placing At All Lifts, Ramming With Iron Rammer, Compacting, Levelling, Curing For 7 Days, Shuttering, Dewatering Wherever Necessary, The Cost Of All Materials, Labour, Leads And Lifts, Tools And Plant, Machineries Etc., Complete As Per Specification. (100Mm Thick) (I) Pcc 1:4:8 , (Ii) Pcc 1:2:4 , Providing And Laying Cast-In-Situ Controlled Reinforced Cement Concrete Of The Following Grades Using 20Mm And Down Size Coarse Graded Machine Crushed Hard Stone Aggregate Including Designing The Mix, Weigh Batching, Mechanical Mixing, Transporting And Placing At All Lifts, Vibrating, Consolidating, Curing And Finishing Smooth As Required All Exposed Faces, Complete For The Following Rc Structural And Other Elements Including Formwork Either Straight, Curved, Plain, Tapered Or Sloped, Supplying And Mixing Admixtures, Dewatering Wherever Necessary, The Cost Of All Complete Materials Labour, All Leads And Lifts, Tools, Plant And Machineries, Hire And Fuel Charges And All Other Incidential Charges Etc., All As Per Specifications, Drawings And As Directed, But Excluding Steel Reinforcement, Irc Mesh, Insert Plates Which Will Be Paid For Separately Under Relevant Items. The Rates Quoted Shall Hold Good For All Foundations At Any Depth, Flooring, All Floors, Heights, Levels, Elevation, Below Ground Level, Basement, Trenches, Pits And Etc Complete. Grade: M35. (I) Pile Cap 750Mm Thk , (Ii) Plinth Beams 230 X 450 , (Iii) Grade Slab 175Mm Thk , (Iv) Floor Deck Slab - 75Mm Thk , (V) Pedestal , Providing And Supplying Of Reinforcement Inclusive Oflabour Charges For Cutting, Straitening, Fabricating And Fixing In Position Ms Bars Conforming To Is-432 / High Yield Strength Deformed Bars (Tor Steel) Conforming To Is-1786 Of Fe 415 Grade / For Pro Steel Confirming To Is-1786 Of Fe550 Of All Dia For Reinforcement In All Rcc In Situ Works Including Flooring And Precast Works At All Levels And Heights Above Finished Floor Level For Plinth Beam, Columns, Roof Beam, Roof Slab, Lintel, Sunshade, Loft, Drops, Sill Level Slab And Etc., And For Foundations, Trenches, Pits, Lift Pits Etc., Below Finished Floor Level Including Cost Of Straightening, Cutting, Bending To Shape Fabricating And Tying With 18 Guage Gi Binding Wire, Providing And Fixing Cement Cover Blocks, Dewatering Wherever Necessary Etc., All Complete As Per Drawings And Specifications And As Directed By The Engineer. The Rate To Include Cost Of Steel,Binding Wire, Cement Cover Blocks, All Cuts And Wastes Which Will Not Be Measured. Only Laid Weight Will Be Measured Including Authorised Laps. Cuts And Wastes Will Not Be Measured For Payment. Reinforcement , Approved Plywood Or Steel Plate Shuttering & Centering For Structural Concrete Work In Locations Called For Including Strutting, Propping, Bracing, Bolting, Wedging, Casing, Striking, Removal, Etc. Complete For Any Size, Section, Or Thickness. Props Shall Consist Of Well-Designed Steel Pipes Adequately Braced( Wooden Ballis As Props Shall Not Be Permitted). The Item To Include Centering & Shuttering At All Heights And Levels. Allow For Forming Grooves, Drip Courses, Chamfers, Cut-Outs, Openings, Etc. Were Called For And For Dressing With Approved Shuttering Oil To Prevent Adhesion. Unexposed Concrete Surfaces, Subsequently Left Untreated (In The Condition Obtained On The Removal Of Formwork) Shall Not Constitute Exposed Concrete Work And Shall Be Measured Under This Item Only. Irregular Shapes With Sides That May Not Be Perpendicular To Each Other Or Shapes Not Confirming Rectangular Or Square Shall Not Be Paid Separately. (Quoted Rate To Include All Staging Up To Any Height) (I) Pile Cap 750Mm Thk , (Ii) Plinth Beams 230 X 450 , (Iii) Grade Slab 175Mm Thk , (Iv) Floor Deck Slab - 75Mm Thk , (V) Pedestal , R.C.C/P.C.C Works Providing And Layingbrick Work Using Bricks Of Class Designation75in Foundations And Upto Plinthlevel In Cementmortar1:6( 1 Cement :6 Coarse Sand ) Including,Joints Finished Flush/Raked To 12 Mm Depth, Etc. Complete As Directed By The Engineer In Charge, (Cleaning Andsoaking The Bricks At Leastfor 24 Hours Before Use , Curing Etc. All Complete At All Heights / Depth). Rate To Include Plastering, Waterpoofing As Per Architect. , Fabrication Works Providing, Fabricating,Transporting, Assembling & Erection In Position Of Steel Members For Steel Columns,Built Up Beams Using Structural Tubular Sections (Round, Square Or Rectangular Hollow Tubes Etc. Confirming To Is 4923 / Is 1161, Yield Strength 310 Mpa As Per Latest Is Code) To The Required Profile & Shape As Called For As Per The Drawing & Specifications. This Item Also Includes The Shear Connectors /Studs & Fusion Weld To Top Of Horizontal Member. This Item Also Includes Preparation Of Shop Drawings & Their Approval, Necessary Templates, Adequate Temporary Supports, Scaffolding & Staging, All Cutting, Grinding, Sliding & All Labour, Tools, Plants& Equipments & Operations Etc. Required To Complete The Job As Per Drawing & Specification. Every Precaution To Be Taken To Prevent Rusting Of Sections. This Item Also Includes All Test On Materials & Welded Fabricated Parts As Per Specification & Direction Of Engineer - In - Charge. Temporary Bolts & Nuts (Grade En 8) To Be Used During Assembling & Shall Be Removed Before Site Erection. All Site Erection Bolts Shall Be Hsfg Type Only. The Item To Include Cost Of Sand Blasting On Materials, Application Of Primer & Various Coats Of Internal & External Painting In Fabrication Shop &Final Painting On Site Including All Touch Up Works After Erection As Per Technical Specification. (I)The Scope Of Work For This Item Includes : A) Design & Fabrication Of Any Additional Temporary Structure Including All Type Of Lifting Brackets, Supporting Brackets, Which Will Be Required For Transportation & Erection In Position / Launching Of Fabrication Part Or Completeelement In Position.B) Making Provision & Arrangement For Required Opening / Inserts For Fixing Lights Fixtures & Funning Cable Conduits . C) All Incidentals .Labour, Equipment & Plants Required To Execute & Complete The Job From Fabrication To Erection At Final Position As Per Drawing, Specification & Direction Of Engineer - In -Charge. D) Cleaning & Removing Of All Spoil, Temporary Arrangement For Casting Of Deck Slab.E) All Safety Measures Required To Execute & Complete The Work.F) Procurement Of All Materials From Approved Manufactures & Fabrication. Complete Methodology For Structural Steel Work . Name Of Workshop For Fabrication Works. Testing Facilities & Erection Procedures Etc.To Be Intimated For Approval Of Engineer - In - Charge. G) The Provision Of Temporary Bearing / Sand Jacks For Supporting Steel Members During Erection. H) Provision Of Stability Duringerection Against Wind Load Or Any Other Type Of Loading On Structural Steel Members During Erection. , (Ii) Measurement Shall Be Only For Structural Steel Which Is Erected & Is Part Of Permanent Structure & Paid As Per Approved Shop Drawings. All Wastages,Temporary Works,Jigs, Temporary Assembly Bolts Etc. Are Deemed To Be Included In Quoted Rates . No Allowance Or Increase In Weight For Welding,Nuts & Bolts Etc Will Be Applicable. , Providing And Fixing Bare Galvalume Sheets Of 0.475 Mm Thk With Self Drilling Screws, Ridge Cap And Rainwater Downtake Pipes Including Fixing Skylight Panels With Butyle Sealant Beads. Brand: Jsw. , Flooring & Cladding False Flooring: The System Should Be Of Nominal 600Mm X 600Mm (35Mm Thick) Modular Panels With Heavy-Duty Pedestals. The Total System Weight Shall Not Exceed 40 Kg/Sq.M. The System Shall Be Able To Withstand A Udl Of 2000 Kg/M2 (1117Kg/Sq.Mt) And A Point Load Of 450 Kg/In2 .Panels Shall Be Made Of Steel With An Infill Of Lightweight, Non-Combustible Having Fireresistance, Thermal Insulation, And Flame Resistance Properties At 60 Min Cementitious Material.The Bottom Of The Panel Shall Be Embossed In Hemispherical Shape To Give Strength And Flexural Rigidity.The Infill Material Shall Not Become Loose When The Panels Are Cut. Panel Should Be Able Towithstand An Ultimate Load Of At Least 2.5 (3.00) Times The Designed Point Load.The Entire Panel Shall Be Coated With Epoxy Powder Coating Of 75-100 Microns On The Exposed Surface.The Panel Top & Bottom Sheet Shall Be 0.9/0.7Mm (0.7/0.6Mm) Resp. Flatness Should Be 0.2Mm.The Panels Shall Have A Top Covering Of Anti-Static High Pressure Laminate With Resistance Of 2X105 –5X108 Ohms. The Hpl Thickness Shall Not Be Less Than 1.5Mm.(1.6Mm).Pedestal Base Shall Be Square Of 100Mm X 100Mm X 2Mm Bearing Area And Assemble To A Tube Of 22Mm Dia With 2Mm Wall Thickness. The Pedestal Head Should Not Be Less Than 3Mm Thick.The Pedestals Should Be Able To Accept An Axial Load Of 22,500N And An Ultimate Load Not Lessthan 45,000N. Pedestal Head Shall Be Galvanized Die-Cut Steel Welded To A Counter Locking Leveling Nut.The Pedestal Head Shall Be Provided With Pvc Cap For Acoustic Dampening. Height Of Pedestal Shall Be Approximate 300 Mm For Floor /150Mm For Steps. , Providing And Fixing Aluminium Composite Panel Of Eurobond/Aludecor Make, Cladding In Combination Of Metallic / Solid Colours, Including All Necessary Frames Work And All Complete. Panel Should Consist Core Of Anti-Toxic Low Density Polyethylene (Ldpe) 3.5Mm Sandwiched Between 2 Skins Of Thick Aluminium Coil Of 0.25Mm. The System Shall Be Installedusing50mm X 50Mm X 50Mm Long 3Mm Thickness G.I L Brackets / 75Mmx50mmx50mm Long 3Mmthicknessg.I.L Brackets @ Min 1.5 Metre Interval Vertically Fastened By 8Mm Dia X 75Mm Long Double Ring/Single Ring Wedge Anchors And 6Mm X 60Mmlong Rawal P/T Type Anchor Fastener Of Uip Brand(Germany Make). 38Mm X 38Mm Thick And 38Mm X25mm L-Angle And 50Mm X 25Mm Box Section Will Be Used For Mullions And Transom With Necessary Accessories, Such As Screws, Rivets, Bolts, Nuts And Washers Shall Be In Zinc Coated/Galvanized Steel.The Bracket Support Shall Be Designed As Per Manufacturers Specification. Sealing Shall Be Done, Using Weather Sealant Of Dowsil Or Equivalent. , Providing And Fixing Corrugated Sheet Cladding In Exterior Elevation In Area / Color As Specified By The Architect To Be Done With Required Channels As Per Manufacterers Specifications. , Providing Andfixing Of 12Mm Thick Bison Board False Ceiling: Metal Framed Suspended Ceiling (Seamless Finish) - Single Layer.False Ceiling Erection To Be With Required Perimeter Channels, Intemediates & Cross Channels As Per Manufacterers Specifications. 6 X 4 Bison Board Fixed With 25Mm Long Self Drilling Screwws With Philips Head. Surface To Be Finished With Jointing Compound And Fibre Taped , Ready To Take Paint Finish.Fixing Channel Size: , Providing Andfixing Of 12Mm Thick Bison Board Partition Walls: To Be Done With Required Channels As Per Manufacterers Specifications On Both Sides Of The Walls/ Partitions. Fixing Channel Size: 65 X 30 Mm / As Per Vendor. , Providing Andfixing Of 9Mm Thick Laminate Cladding On Interior Walls: To Be Done With Required Channels As Per Manufacterers Specifications On Both Sides Of The Walls/ Partitions. 1350 X 295 Panel , Brand : Vox , Providing Andfixing Of Parametric Mdf Panel With Laminate Finish-Fire Rated To Be Done With Required Channels As Per Manufacterers Specifications On Specified Walls/ Partitions, Panel Size 8 X 4 , Base Board 25Mm= 1 Sheet & Parametric Panel 11Mm (Vertical)= 45 Strip, Brand: Glopanel, Fixing Channel Size: 65 X 30 Mm / As Per Vendor. , Providing And Laying Groundcover - Pebbles - Size 50-75Mm Below Staircase. , Providing And Laying Carpet Flooring Over False Flooring, Color And Pattern As Specified By The Architect. , Providing Andfixing Of Vinyl Printed Display Boards On Interior Walls: To Be Done With Required Channels As Per Manufacterers Specifications On Both Sides Of The Walls/ Partitions. , Providing And Laying Machine Cut, Leather Polished Granite Slab Flooring Of Approved Sample, 18Mm Thick And Size As Per Drawings, In Approved Pattern, As Per The Drawings Provided By The Architect, By Applying Mortar To The Substrate With The Flat Side Of The Trowel, Pressing Firmly To Work It Into The Surface; Combing On Additional Mortar With The Notched Side Ue The Proper Sized Notched Trowel For The Stone To Ensure Full Bedding Of The Stone On Checkered Plate Etc. Complete. , Door / Window / Glass Work Providing And Fixing Steel Door Of Size As Mentioned Below With Tata Pravesh Brand -Constructed From 0.0008M Swg Gi Sheet. 0.046M Thk, Frame Of 0.1 X 0.058 Galvanized Iron Profile Dimension, Powder Coated, Ss Ball Bearing Butt Hinges, Mortise Sash Lock With Handles,Mortise Dead Bolt,Latch, Panic Device Provided. -Main Door / Server Room Door , Fire Rated Door Providing And Fixing Steel Door Of Size As Mentioned Below With Tata Pravesh Brand -Constructed From 0.0012M Swg Gi Sheet. 0.046M Thk, Frame Of 0.1 X 0.058 Galvanized Iron Profile Dimension, Powder Coated, Ss Ball Bearing Butt Hinges, Mortise Sash Lock With Handles,Mortise Dead Bolt,Latch, Panic Device Provided. -Service Door , Providing And Fixing Of Toughened Glass Floor Over The Digital Diaply Flooring Using Ms Structure (80Mm X 80Mm X 4Mm Thick As Outer Section And 80Mm X 40Mm X 4Mm Thick As Inner Section) And Glass (8Mm St 167 Toughened Glass + 1.52Mm Clear Pvb + 8Mm St 167 Toughened Glass) Using Spacer Tape With All Other Necessary Accessories. And Need To Arrest 8Mm Fiber Cement Panel With Painting. The Cost Including Of Glass Loading, Fixing And Transport Charges. , Providing And Fixing Anodized/Powder Coated Aluminum Worksliding Doors With Extruded Built Up Standard Tubular And Other Sections Of Approved Made Confirming To Is 733 And Is 1285, Anodic Or Transparent Or Dyed To Required Shade According To Is:1868 (Minimum Anodic Coating Of Grade Ac 15), Fixed With Rawl Plugs And Screws, Or With Fixing Clips, Or With Expansion Hold Fasteners Including Necessary Filling Up The Gaps At Junctions, Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitered And Jointed Mechanically, Wherever Required Including Cleat Angle, All Necessary Hardware Fittings All Complete As Per Architectural Drawings And As Directed The Glass Should Be 5/6Mm Thick Toughened Glass Of Modi/ Saint Gobain Or Equivalent.Ss Mosquito Mesh Mesh Gap: 1.3Mm Opening Aperture, Wire Dia: 30 Swg Material As Per Ss: 2245 Material Grade: Aisi 304. The Cost Includes All Material Machinery Andlabour Including Scaffolding And Any Other Preparatory Work To Install And Complete And Clean As Directed By Engineer In Charge , Miscellaneous Providing And Fixing Of Glass Canopy Using Ms Structure (80Mm X 80Mm X 4Mm Thick As Outer Section And 80Mm X 40Mm X 4Mm Thick As Inner Section) And Glass (8Mm St 167 Toughened Glass + 1.52Mm Clear Pvb + 8Mm St 167 Toughened Glass) Using Spacer Tape With All Other Necessary Accessories. And Need To Arrest 8Mm Fiber Cement Panel With Painting. The Cost Including Of Glass Loading, Fixing And Transport Charges. - Over Main & Service Doors , Monkey Ladder Height: 3.5M / Width: 0.6M , Invisible Grill: 3Mm Dia : @250Mm C/C- Staircase And Parapet , Sub Head B - Electrical Works Part-A Wiring Supply, Installation, Testing And Commissioning Of Surface/Concealed Type Of Point Wiring With Modular Type Switches, Sockets And All Materials As Per The Point Wiring Chart. The Item Including Cost Of Supply And Installation Of 25Mm Pvc Conduits, Couplers, Junction Boxes, Bends, Ceiling/Wall Plates, Metal Boxes, Switches, Sockets, Draw Boxes & Top Cover Plate (3Mm Hylam Sheet), 3 Run Of 1.5Sq.Mm Frls Copper Wires, Bakelite Connectors, Crimping Type Ferrules, Copper Lugs, Brass Cup Washers & Brass Screws, Clamps & Screws And Bolt & Nuts Etc. All The Points Shall Be Terminated With 300Mm Length Of Additional Wires Along With Connector Terminal Blocks. The Item Including Necessary Chipping/Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. (I) One Light / Exhaust Fan / Wall Mounting Fan Point Controlled By One No. 1-Way 6 Amps Switch. (Upto 4M) , (Ii) One Light / Exhaust Fan / Wall Mounting Fan Point Controlled By One No. 1-Way 6 Amps Switch. (Upto 6M) , (Iii) One Light / Exhaust Fan / Wall Mounting Fan Point Controlled By One No. 1-Way 6 Amps Switch. (Upto 9M) , (Iv) One Light / Exhaust Fan / Wall Mounting Fan Point Controlled By One No. 1-Way 6 Amps Switch. (Upto 12M) , (V) Six Light Points Controlled By One No. Mcb (Upto 12M) , (Vi) Seven Light Points Controlled By One No. Mcb (Upto 12M) , (Vii) One Light / Exhaust Fan / Wall Mounting Point Controlled By Two Nos. 2-Way 6 Amps Switch. (Upto 12M) , (Viii) One Additional Light Point Extended From The Existing Light Point And Controlled By Existing Switch. (All Items Are As Similar To {A1.A} But Excluding Of Switch Boxes, Switches And Sockets) (Upto 3M Length) , (Ix) One Additional Light Point Extended From The Existing Light Point And Controlled By Existing Switch. (All Items Are As Similar To {A1.A} But Excluding Of Switch Boxes, Switches And Sockets) (Upto 4M Length) , (X) One Additional Light Point Extended From The Existing Light Point And Controlled By Existing Switch. (All Items Are As Similar To {A1.A} But Excluding Of Switch Boxes, Switches And Sockets) (Upto 6M Length) , (Xi) One Additional Light Point Extended From The Existing Light Point And Controlled By Existing Switch. (All Items Are As Similar To {A1.A} But Excluding Of Switch Boxes, Switches And Sockets) (Upto 9M Length) , (Xii) One Additional Light Point Extended From The Existing Light Point And Controlled By Existing Switch. (All Items Are As Similar To {A1.A} But Excluding Of Switch Boxes, Switches And Sockets) (Upto 12M Length) , Supply, Installation, Testing And Commissioning Of Surface/Concealed Type Of Point Wiring With Modular Type Switches, Sockets And All Materials As Per The Point Wiring Chart. The Item Including Cost Of Supply And Installation Ofmetal Boxes, Switches, Sockets, Draw Boxes & Top Cover Plate (3Mm Hylam Sheet), 3 Run Of 1.5Sq.Mm Frls Copper Wires, Bakelite Connectors, Crimping Type Ferrules, Copper Lugs, Brass Cup Washers & Brass Screws, Clamps & Screws And Bolt & Nuts Etc. All The Points Shall Be Terminated With 300Mm Length Of Additional Wires Along With Connector Terminal Blocks. The Item Including Necessary Chipping/Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. (The Item Excluding Cost Of 19Mm/25Mm Dia Pvci.E, Point Wiring In The Existing Conduits) (I) One Light / Exhaust Fan / Wall Mounting Fan Point Controlled By One No. 1-Way 6 Amps Switch. (Upto 4M) , (Ii) One Light / Exhaust Fan / Wall Mounting Fan Point Controlled By One No. 1-Way 6 Amps Switch. (Upto 6M) , (Iii) One Light / Exhaust Fan / Wall Mounting Fan Point Controlled By One No. 1-Way 6 Amps Switch. (Upto 9M) , (Iv) One Light / Exhaust Fan / Wall Mounting Fan Point Controlled By One No. 1-Way 6 Amps Switch. (Upto 12M) , (V) Six Light Points Controlled By One No. Mcb (Upto 12M) , (Vi) Seven Light Points Controlled By One No. Mcb (Upto 12M) , (Vii) One Light / Exhaust Fan / Wall Mounting Point Controlled By Two Nos. 2-Way 6 Amps Switch. (Upto 12M) , (Viii) One Additional Light Point Extended From The Existing Light Point And Controlled By Existing Switch. (All Items Are As Similar To {A1.A} But Excluding Of Switch Boxes, Switches And Sockets) (Upto 3M Length) , (Ix) One Additional Light Point Extended From The Existing Light Point And Controlled By Existing Switch. (All Items Are As Similar To {A1.A} But Excluding Of Switch Boxes, Switches And Sockets) (Upto 4M Length) , (X) One Additional Light Point Extended From The Existing Light Point And Controlled By Existing Switch. (All Items Are As Similar To {A1.A} But Excluding Of Switch Boxes, Switches And Sockets) (Upto 6M Length) , (Xi) One Additional Light Point Extended From The Existing Light Point And Controlled By Existing Switch. (All Items Are As Similar To {A1.A} But Excluding Of Switch Boxes, Switches And Sockets) (Upto 9M Length) , (Xii) One Additional Light Point Extended From The Existing Light Point And Controlled By Existing Switch. (All Items Are As Similar To {A1.A} But Excluding Of Switch Boxes, Switches And Sockets) (Upto 12M Length) , Supply, Installation, Testing And Commissioning Of Surface/Concealed Type Of Point Wiring With Modular Type Switches, Sockets And All Materials As Per The Point Wiring Chart. The Item Including Cost Of Supply And Installation Of 25Mm Frls Conduits, Couplers, Junction Boxes, Bends, Ceiling/Wall Plates, Metal Boxes, Switches, Sockets, Draw Boxes & Top Cover Plate (3Mm Hylam Sheet), 3 Run Of 1.5Sq.Mm Frls Copper Wires, Bakelite Connectors, Crimping Type Ferrules, Copper Lugs, Brass Cup Washers & Brass Screws, Clamps & Screws And Bolt & Nuts Etc. All The Points Shall Be Terminated With 300Mm Length Of Additional Wires Along With Connector Terminal Blocks. The Item Including Necessary Chipping/Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. (I) One Light / Exhaust Fan / Wall Mounting Fan Point Controlled By One No. 1-Way 6 Amps Switch. (Upto 4M) , (Ii) One Light / Exhaust Fan / Wall Mounting Fan Point Controlled By One No. 1-Way 6 Amps Switch. (Upto 6M) , (Iii) One Light / Exhaust Fan / Wall Mounting Fan Point Controlled By One No. 1-Way 6 Amps Switch. (Upto 9M) , (Iv) One Light / Exhaust Fan / Wall Mounting Fan Point Controlled By One No. 1-Way 6 Amps Switch. (Upto 12M) , (V) Six Light Points Controlled By One No. Mcb (Upto 12M) , (Vi) Seven Light Points Controlled By One No. Mcb (Upto 12M) , (Vii) One Light / Exhaust Fan / Wall Mounting Point Controlled By Two Nos. 2-Way 6 Amps Switch. (Upto 12M) , (Viii) One Additional Light Point Extended From The Existing Light Point And Controlled By Existing Switch. (All Items Are As Similar To {A1.A} But Excluding Of Switch Boxes, Switches And Sockets) (Upto 3M Length) , (Ix) One Additional Light Point Extended From The Existing Light Point And Controlled By Existing Switch. (All Items Are As Similar To {A1.A} But Excluding Of Switch Boxes, Switches And Sockets) (Upto 4M Length) , (X) One Additional Light Point Extended From The Existing Light Point And Controlled By Existing Switch. (All Items Are As Similar To {A1.A} But Excluding Of Switch Boxes, Switches And Sockets) (Upto 6M Length) , (Xi) One Additional Light Point Extended From The Existing Light Point And Controlled By Existing Switch. (All Items Are As Similar To {A1.A} But Excluding Of Switch Boxes, Switches And Sockets) (Upto 9M Length) , Supply, Installation, Testing And Commissioning Of Surface/Concealed Type Of Point Wiring With Modular Type Switches, Sockets And All Materials As Per The Point Wiring Chart. The Item Including Cost Of Supply And Installation Of 25Mm Ms Conduits, Couplers, Junction Boxes, Bends, Ceiling/Wall Plates, Metal Boxes, Switches, Sockets, Draw Boxes & Top Cover Plate (3Mm Hylam Sheet), 3 Run Of 1.5Sq.Mm Frls Copper Wires, Bakelite Connectors, Crimping Type Ferrules, Copper Lugs, Brass Cup Washers & Brass Screws, Clamps & Screws And Bolt & Nuts Etc. All The Points Shall Be Terminated With 300Mm Length Of Additional Wires Along With Connector Terminal Blocks. The Item Including Necessary Chipping/Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. (I) One Light / Exhaust Fan / Wall Mounting Fan Point Controlled By One No. 1-Way 6 Amps Switch. (Upto 4M) , (Ii) One Light / Exhaust Fan / Wall Mounting Fan Point Controlled By One No. 1-Way 6 Amps Switch. (Upto 6M) , (Iii) One Light / Exhaust Fan / Wall Mounting Fan Point Controlled By One No. 1-Way 6 Amps Switch. (Upto 9M) , (Iv) One Light / Exhaust Fan / Wall Mounting Fan Point Controlled By One No. 1-Way 6 Amps Switch. (Upto 12M) , (V) Six Light Points Controlled By One No. Mcb (Upto 12M) , (Vi) Seven Light Points Controlled By One No. Mcb (Upto 12M) , (Vii) One Light / Exhaust Fan / Wall Mounting Point Controlled By Two Nos. 2-Way 6 Amps Switch. (Upto 12M) , (Viii) One Additional Light Point Extended From The Existing Light Point And Controlled By Existing Switch. (All Items Are As Similar To {A1.A} But Excluding Of Switch Boxes, Switches And Sockets) (Upto 3M Length) , (Ix) One Additional Light Point Extended From The Existing Light Point And Controlled By Existing Switch. (All Items Are As Similar To {A1.A} But Excluding Of Switch Boxes, Switches And Sockets) (Upto 4M Length) , (X) One Additional Light Point Extended From The Existing Light Point And Controlled By Existing Switch. (All Items Are As Similar To {A1.A} But Excluding Of Switch Boxes, Switches And Sockets) (Upto 6M Length) , (Xi) One Additional Light Point Extended From The Existing Light Point And Controlled By Existing Switch. (All Items Are As Similar To {A1.A} But Excluding Of Switch Boxes, Switches And Sockets) (Upto 9M Length) , (Xii) One Additional Light Point Extended From The Existing Light Point And Controlled By Existing Switch. (All Items Are As Similar To {A1.A} But Excluding Of Switch Boxes, Switches And Sockets) (Upto 12M Length) , Power Receptacles Supply, Installation, Testing And Commissioning Of Power Points By Providing Following Switches/Sockets, Mounted Flush To The Walls Usingms Boxes, Inner Plates, Front Plate, Modular Switches And Sockets With All Wiring Accessories. (I) One 6A Dependent 5-Pin Socket Point Controlled By One No Of 6A Switch. (Switch & Socket Are Mounted In A Dependent Switch Box) , (Ii) One 6A Independent 5-Pin Socket Point Controlled By One No Of 6A Switch. (Switch & Socket Are Mounted In An Independent Switch Box White Colour) , (Iii) One 6A Independent 5-Pin Socket Point Controlled By One No Of 6A Switch. (Switch & Socket Are Mounted In An Independent Switch Box Black Colour) , (Iv) One 6A One Way Independent 5-Pin Socket With Terminations , (V) One 6A One Way Dependent/Independent Switch With Terminations , (Vi) One 6A/16A 5-Pin Socket Point Controlled By One 16A Switch With Indicator. (Switch & Socket Are Mounted In An Independent Switch Box) , (Vii) Two Nos 6A/16A 5-Pin Socket Point Controlled By Two Nos 16A Switch With Indicator. (Switch & Socket Are Mounted In An Independent Switch Box White Colour) , (Viii) Two Nos 6A/16A 5-Pin Socket Point Controlled By Two Nos 16A Switch With Indicator. (Switch & Socket Are Mounted In An Independent Switch Box Black Colour) , (Ix) Two Nos Of 6A Independent 5-Pin Socket Points Controlled By Two Nos Of 6A Switches. (White Colour) , Supply, Installation, Testing And Commissioning Of Power Points By Providing Following Switches/Sockets, Mounted Flush To The Walls Usingms Boxes, Inner Plates, Front Plate, Modular Switches And Sockets With All Wiring Accessories. (I) 2 Module , (Ii) 3 Module , (Iii) 4 Module , (Iv) 6 Module , (V) 8 Module , (Vi) 12 Module , (Vii) 16 Module , Supply, Installation, Testing And Commissioning Of Surface/Concealed Type Of Main Circuit Wiring From Panel/Db To Dbs, Db To Switch Boxes And Switch Box To Other Switch Boxes Using 1100V Grade Pvc Insulated Multistranded Frls Copper Wires, To Be Drawn Through Existing Laid Conduits. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. (The Item Excluding Cost Of 25Mm Dia Frls Pvc/Ms Conduit-Circuit Wiring In The Existing Conduits) (I) 3 Runs Of 1.5 Sq.Mm. Frls Copper Wiring In The Existing Laid Frls Pvc/Ms Conduits. (This Item Will Be Considered Only Where The Point Wiring Exceeds The Mentioned Length) , (Ii) 2 Runs Of 2.5 Sq.Mm. & 1 Run Of 1.5 Sq.Mm. Frls Copper Wiringin The Existing Laid Frls Pvc/Ms Conduits. , (Iii) 2 Runs Of 4 Sq.Mm. & 1 Run Of 2.5 Sq.Mm. Frls Copper Wiringin The Existing Laid Frls Pvc/Ms Conduits. , (Iv) 2 Runs Of 6 Sq.Mm. & 1 Run Of 2.5 Sq.Mm. Frls Copper Wiringin The Existing Laid Frls Pvc/Ms Conduits. , (V) 4 Runs Of 4 Sq.Mm. & 2 Runs Of 2.5 Sq.Mm. Frls Copper Wiringin The Existing Laid Frls Pvc/Ms Conduits. , (Vi) 4 Runs Of 6 Sq.Mm. & 2 Runs Of 2.5 Sq.Mm. Frls Copper Wiringin The Existing Laid Frls Pvc/Ms Conduits. , (Vii) 4 Runs Of 10 Sq.Mm. & 2 Runs Of 4 Sq.Mm. Frls Copper Wiringin The Existing Laid Frls Pvc/Ms Conduits. , Supply And Installlation Of Surface/Recessed Type Frls Pvc, Rigid/Flexible, Conduits Of The Following Sizes With Required Couplers, Junction Boxes, Bends, Ceiling/Wall Plates, Metal Boxes, Draw Boxes & Top Cover Plate (3Mm Hylam Sheet), Clamps, Screws, Bolt & Nuts And Necessary Fixing Accessories Etc. The Item Including Necessary Chipping/Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer: (I) 20Mm Dia 2Mm Thick Rigid Pvc Conduits. , (Ii) 25Mm Dia 2Mm Thick Rigid Pvc Conduits. , (Iii) 20Mm Dia 1.6Mm Thick Rigid Pvc Conduits. , (Iv) 25Mm Dia 1.6Mm Thick Rigid Pvc Conduits. , (V) 20Mm Dia 2Mm Thick Rigid Frls Pvc Conduits. , (Vi) 25Mm Dia 2Mm Thick Rigid Frls Pvc Conduits. , (Vii) 20Mm Dia 1.6Mm Thick Rigid Frls Pvc Conduits. , (Viii) 25Mm Dia 1.6Mm Thick Rigid Frls Pvc Conduits. , (Ix) 20Mm Dia 1.6Mm Thick Rigid Ms Conduits. , (X) 25Mm Dia 1.6Mm Thick Rigid Ms Conduits. , Part-B- Distribution Board Supply, Installation, Testing And Commissioning Of Following Ways Of Surface/Flush Mounting, Double Door Phase Segregation Seven Segment Type Tpn Mcb Dbs Of Sheet Steel, Powder Coated, Ip42 Protection, Metal Door And Cable End Box Etc. The Item Including Terminal Connectors For All Incoming And Outgoing Circuits, Duly Pre-Wired With Suitable Size Of Frls Pvc Copper Wires Upto Terminal Blocks, Tinned Copper Bus Bar Of Suitable Rating, Neutral Links, Earth Bars, Detachable Gland Plate, Interconnections By Using Crimping Type Ferrules & Copper Lugs, And Engraving Of Laminated As-Built Circuit Drawings In The Door Inside Etc. The Item Including Necessary Chipping/Cutting The Wall And Making Good The Same In Case Of Flush Mounting As Required. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer: (I) 4Way , (Ii) 6Way , Supply, Installation, Testing And Commissioning Of Following Ways Of Surface/Flush Mounting, Vtpn Mcb Dbs Of Sheet Steel, Powder Coated, Ip43 Protection, Metal Door And Cable End Box Etc. The Item Including Terminal Connectors For All Incoming And Outgoing Circuits, Duly Pre-Wired With Suitable Size Of Frls Pvc Copper Wires Upto Terminal Blocks, Tinned Copper Bus Bar Of Suitable Rating, Neutral Links, Earth Bars, Detachable Gland Plate, Interconnections By Using Crimping Type Ferrules & Copper Lugs, And Engraving Of Laminated As-Built Circuit Drawings In The Door Inside Etc. The Item Including Necessary Chipping/Cutting The Wall And Making Good The Same In Case Of Flush Mounting As Required. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer: 12 Way , Supply, Installation, Testing And Commissioning Of Following Ways Of Surface/Flush Mounting, Spn Mcb Dbs Of Sheet Steel, Powder Coated, Ip43 Protection, Metal Door And Cable End Box Etc. The Item Including Terminal Connectors For All Incoming And Outgoing Circuits, Duly Pre-Wired With Suitable Size Of Frls Pvc Copper Wires Upto Terminal Blocks, Tinned Copper Bus Bar Of Suitable Rating, Neutral Links, Earth Bars, Detachable Gland Plate, Interconnections By Using Crimping Type Ferrules & Copper Lugs, And Engraving Of Laminated As-Built Circuit Drawings In The Door Inside Etc. The Item Including Necessary Chipping/Cutting The Wall And Making Good The Same In Case Of Flush Mounting As Required. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer: (I) 8Way , (Ii) 12Way , Supply, Installation, Testing And Commissioning Of Following Ratings & Poles Of Single Phase / Three Phase C Curve, 10Ka Mcbs To Be Fixed In The Existing Mccb/Mcb Dbs Or Enclosures Complete With Interconnections By Using Crimping Type Ferrules And Copper Lugs Etc. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer: (I) 6A To 32A Single Pole Mcb , (Ii) 40A To 63A Singl Pole Mcb , (Iii) 6A To 32A Singl Pole Neutral / Double Pole Mcb , (Iv) 40A To 63A Singl Pole Neutral / Double Pole Mcb , (V) 6A To 32A Triple Pole Mcb , (Vi) 40A To 63A Triple Pole Mcb , (Vii) 6A To 32A Four Pole Mcb , (Viii) 40A To 63A Four Pole Mcb , Supply, Installation, Testing And Commissioning Of Following Ratings & Poles Of Three Phase 18Ka Adjustable Thermal Magnetic Release Type Mccbs To Be Fixed In The Existing Mccb Dbs Or Panels Or Enclosures Complete With Interconnections By Using Crimping Type Ferrules And Copper Lugs Etc. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer:100A Four Pole Mccb , Supply, Installation, Testing And Commissioning Of Following Ratings & Poles Of Single Phase / Three Phase Rccbs To Be Fixed In The Existing Mccb/Mcb Dbs Or Enclosures Complete With Interconnections By Using Crimping Type Ferrules And Copper Lugs Etc. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer: (I) 25A Double Pole Rccb, 30Ma , (Ii) 63A Four Pole Rccb, 30Ma , (Iii) 40A Four Pole Rccbo, 30Ma , (Iv) 32A Four Pole Rccbo, 300Ma , (V) 63A Four Pole Rccb, 300Ma , Supply And Installation Of Blanking Plates In The Existing Mccb/Mcb Dbs Or Enclosures Etc. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer: , Supply, Installation, Testing And Commissioning Of Following Ratings & Poles Of Single Phase / Three Phase Rccbs To Be Fixed In The Existing Mccb/Mcb Dbs Or Enclosures Complete With Interconnections By Using Crimping Type Ferrules And Copper Lugs Etc. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer: (I) Double Pole Enclosure For Mcbs , (Ii) Four Pole Enclosure For Mcbs , Supply, Installation, Testing And Commissioning Of Following Weather Proof Boxsuitable For Independent Mounting Of Mcb/Mccb/Rccbs Complete With All Necessary Fixing Accessories Etc. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer: (I) Double Pole Enclosure For Mcbs , (Ii) Four Pole Enclosure For Mcbs , Supply, Installation, Testing And Commissioning Of Following Weather Proof Boxsuitable For Independent Mounting Of Mcb/Mccb/Rccbs Complete With All Necessary Fixing Accessories Etc. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer: (I) 100 X 100 X 50 Mm , (Ii) 150 X 150 X 50 Mm , (Iii) 300 X 300 X 50 Mm , Part-C Luminaires And Fixtures Installing, Testing And Commissioning Of The Following Luminairesincluding Driver, Connecting Wire,Clamps, Screws, Bolt & Nuts, Down Rods, Required Connector Block Terminals And Necessary Fixing Accessories Etc. (I) 230V, 18W Led Spot Light Luminarie. , (Ii) 230V, 15W Led Down Light Luminaire , (Iii) 230V, 15W Led 8 Profile Light Luminaire , (Iv) 230V,15-20W/Meter Led Strip Light Fittings. , Installing, Testing And Commissioning Of Wall Mounted Fan , With Mounting Frame, All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. , Part-D Lt Panels Supply,Installation, Testing And Commissioning Of 415V Cubical Type, Fully Compartmenalised, Floor Mounted Type Lt Switch Boards Fabricated With 14G Crca Sheet, Powder Coated With Siemens Grey (Ral 7032) After Seven Tank Process And Complete With Welded & Bolted Design And All Incoming & Outgoing Switch Gears As Per The Following.Suitable Aluminuim Busbars, Control Wiring, Control Fuses, Seperate Metering Compartment (Incoming) With Multi Function Meter, Phase Indications With Necessary Control Wiring. Safety Features And Items Including Necessary Earthing Throughout The Bottom Length, 6 Sq.Mm Frls Copper Wire Interconnections For Compartment Earthing, Complete Copper Control Wiring With Crimping Type Ferrules, Copper Lugs, Proper Engravation On Each Compartment Etc.The Switch Boards Shall Be Cpri Approved Of Factory Assembled And Tested. All The Mccbs With Micro Processor/Thermal Magnetic Releases And Have Rotary Handle Mechanism & Spreader Current Density Not More Than 0.7A/Sq.Mm For Aluminium Bus Bar. Neutral Current Rating Is Half The Phase Currentall Busbars Shall Be Fixed With Standard Space Clearance And With Colour Coated Heat Shrinkable Pvc Sleeves With Dmc/Smc Bus Bar Supports And Suitable Earth Bus (25 X 3Mm Cu).The Cable Entry Shall Be From The Bottom/Top As Per Site Requirement.The Item Including Cost Of Ms Base Frame Of 75Mm Height, 3.15Mm Sheet Steel Or 40X40x6mm Ms Angle For Load Bearing Members, Lifting Hooks, Steel Support Structure Required For Erection And Its Painting, Minor Civil Works, Vendor Drawings, Necessary Safety Clearance From Statutory Authorities, Panel Approval From Tneb Till Obtaining Final Power Supply, All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer.The Contractor Shall Submit General Arrangement & Control Wiring Drawings And Get Approval From Site Engineer/Consultant Before Commence The Fabrication Works. Sub Panelincomer: (I) 100A 4P On-Load Auto Change Over Switch With Control Mcbs, With Rotary Handle Mechanism & Spreader And Phase Indications Etc. - 1 No. (Ii) 100A, Tpn, 25Ka, Mccb With Adjustable Thermal Magnetic Releases And Rotary Handle Mechanism & Spreader- 1 No , Metering:(I)3 Nos-Ct Ratio 100/5A,Cl:1.0 Tape Insulated Type With Suitable Sorting Links..(Ii) 3 Nos-Ct Ratio 100/5A,Cl:1.0, 15Va Tape Insulated Type With Suitable Sorting Links Power Factor Sensingrelay1 Set – Indication Lamps For R,Y,B, Breaker On(Red), Breaker Off (Green), Breaker Trip (Amber) With Control Mcbs.Bus Bar:100A, Tpn, 25Ka, For 1 Sec Aluminium Bus Bar (I)Phase: Current Density Not More Than .7A/Sq.Mm(Ii)Neutral: Half Of The Phase Current (0.5 X Phase) (Iii) Earth: 25X3mm Copper Flatoutgoing:(I)63A Fp 10Ka Mcb C Curve- 3 Nos(Ii) 40A Fp 10Ka Mcb C Curve- 1 No(Iii)32A Fp 10Ka Mcb C Curve- 3 Nos (Iv) 16-32A Dp 10Ka Mcb C Curve- 1 Nonote:All Outgoing Feeders Should Be Provided In Individual Compartment , Supply, Installation, Testing And Commissioning Of 415V Cubical Type, Non Compartmenalised, Floor/Wall Mounted Type Automatic Power Factor Correction Panel Board Fabricated With 14G Crca Sheet, Powder Coated After Seven Tank Process And Complete With Bolted Design And The Provisions As Follows. Gas Filled Cylindricalheavy Duty Capacitors (App Type) Of 10Kvar . The Switch Boards Shall Be Cpri Approved Of Factory Assembled And Tested.The Cable Entry Shall Be From The Bottom/Top, Suitable Aluminuim Busbars, Control Wiring, Control Fuses, Seperate Metering Compartment, Phase Indications, Safety Features And Items Including Necessary Earthing Throughout The Bottom Length, 6 Sq.Mm Frls Copper Wire Interconnections For Compartment Earthing, Complete Copper Control Wiring With Crimping Type Ferrules, Copper Lugs, Proper Engravation On Each Compartment Etc. Also The Cost Inclusive Of Ms Base Frame, Steel Support Structure Required For Erection And Its Painting, Minor Civil Works, Vendor Drawings, Necessary Safety Clearance From Statutory Authorities, Panel Approval Fromceig/Tneb/Tangedco Till Obtaining Final Power Supply, All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. All The Mccbs With Micro Processor / Thermal Magnetic Releases And Have Rotary Handle Mechanism. Each Compartment/Section Shall Have Exhaust Fans The Incoming Shall Have Metering, Ammeter & Voltmeter With Selector Switches, Ryb Indication Lamp With Control Mcbs And 8 Stage Apfc Relay Etc. Each Outgoings Shall Have Set Of Capacitor Duty Contactors, Set Of On/Off Indication Lamps And Set Of On/Off Push Button Etc. Incomer:(I)32A 4P 10Ka Mcb C Curve- 1 No Bus Bar:100A, Tpn, 25Ka, For 1 Sec Aluminium Bus Bar(I) Phase: Current Density Not More Than 0.8A/Sq.Mm(Ii)Neutral: Half Of The Phase Current (0.5 X Phase) (Iii) Earth : 25 X 3 Mmcopper Flat Outgoing:(I)3 Kvar Feeder Fitted With 25A Tp 10Ka Mcb - 1 No. (Ii) 2 Kvar Feeder Fitted With 20A Tp 10Ka Mcb - 1 No.(Iii) 1 Kvar Feeder Fitted With 20A Tp 10Ka Mcb - 5 Nos , Lt 3 Phase Metering Panel Lt 3 Phase Metering Panel With Tpn Fuse And Metering Provisions For 1 No As Per Tneb Standard With Double Earthing.100A,Rwf Fuse (3Nos) + Neutral Link- 1 Set 100A, Fp, 25Ka, Mccb With Adjustable Thermal Magnetic Releases And Rotary Handle Mechanism & Spreader - 1 No. , Part-Elt Cabling Supply, Laying, Testing And Commissioning Of Following 1.1Kv Grade Multicore Aluminium Conductor Xlpe/Pvc Insulated Gi Round(Upto 10Sqmm) / Flat(16Sqmm And Above) Armoured Pvc Sheathed Cables (Without Any Cable Joint) Drawn Through Tray Or Steel Supports Or Clamping On The Ceiling/Wall Or Pre-Excavated / Pre-Formed Trenches Or Gi Pipe Sleeves / Hume Pipes With Suitable Clamping Arrangement And Fixing Accessories, Cable Routemarkers, Cable Ties, Identification Tags Etc. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. (I) 3.5C X 50 Sq.Mm Aluminium Xlpe Cable , (Ii) 3.5C X 35 Sq.Mm Aluminium Xlpe Cable , (Iii) 4C X 16 Sq.Mm Aluminium Xlpe Cable , (Iv) 4C X 10 Sq.Mm Aluminium Xlpe Cable , (V) 4C X 6 Sq.Mm Aluminium Xlpe Cable , Supply, Laying, Testing And Commissioning Of Following 1.1Kv Grade Multicore Copper Conductor Xlpe/Pvc Insulated Gi Round(Upto 10Sqmm) / Flat(16Sqmm And Above) Armoured Pvc Sheathed Cables (Without Any Cable Joint) Drawn Through Tray Or Steel Supports Or Clamping On The Ceiling/Wall Or Pre-Excavated / Pre-Formed Trenches Or Gi Pipe Sleeves / Hume Pipes With Suitable Clamping Arrangement And Fixing Accessories, Cable Routemarkers, Cable Ties, Identification Tags Etc. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. (I) 4C X 10 Sq.Mm Copper Xlpe Cable , (Ii) 4C X 6 Sq.Mm Copper Xlpe Cable , (Iii) 4C X 4 Sq.Mm Copper Xlpe Cable , Supply And Termination Of The Following Sizes Of 1.1Kv Xlpe/Pvc Insulated Al/Cu Conductor Cables With Single Compression Brass Cable Glands And Tinned Copper Lugs Including Gland Earth Clips, Adequate Size Of Bare Copper Wire Connecting To The Main Bus Bars Etc. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. (I) 3.5C X 50 Sq.Mm Aluminium Xlpe Cable , (Ii) 3.5C X 35 Sq.Mm Aluminium Xlpe Cable , (Iii) 4C X 16 Sq.Mm Aluminium Xlpe Cable , (Iv) 4C X 10 Sq.Mm Aluminium Xlpe Cable , (V) 4C X 6 Sq.Mm Aluminium Xlpe Cable , (Vi) 4C X 10 Sq.Mm Copper Xlpe Cable , (Vii) 4C X 6 Sq.Mm Copper Xlpe Cable , (Viii) 4C X 4 Sq.Mm Copper Xlpe Cable , Supply And Erection Of Following Size Of Hot Dip Gi Ladder Type Cable Trays Including Horizontal And Vertical Bends, Reducers, Tees, Right Angles, Cross Members And Other Accessories Etc. The Item Including Cost Of Steel Support Structures At Every 0.6M/1M Intervels As Required For Suspend From The Ceiling Or Supported From Walls With Ms Suspenders/Brackets And All Complete With Painting/Powder Coating Etc. All Complete As Per The Specifications / Drawings Ad Or As Directed By The Engineer. (I) 150 X 50 X 2Mm , (Ii) 200 X 50 X 2Mm , (Iii) 300 X 50 X 2Mm , Supply And Erection Of Following Size Of Perforated Gi Cable Trays Including Horizontal And Vertical Bends, Reducers, Tees, Right Angles, Cross Members And Other Accessoriess Etc. The Item Including Cost Of Steel Support Structures At Every 0.6M/1M Intervels As Required For Suspend From The Ceiling Or Supported From Walls With Ms Suspenders/Brackets And All Complete With Painting/Powder Coating Etc. All Complete As Per The Specifications / Drawings Ad Or As Directed By The Engineer. (I) 150 X 50 X 2Mm Without Cover , (Ii) 200 X 50 X 2Mm Without Cover , (Iii) 300 X50 X 2Mm Without Cover , (Iv) 450 X50 X 2Mm Without Cover , Laying Cables Buried Underground At 750Mm. From Fgl Including Necessary Excavation, Supply And Placingof Cable Markers And Backfilling In Compacted Layers, All Complete As Per Specifications, Drawings And /Or As Directed By The Engineer. , Supply, Installation Of Following Sizes Of Heavy Duty Pvc Pipe For Cable Crossing Of Basement Cable Entry & External Lights And The Like, All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. (I) 50Mm Dia , (Ii) 100Mm Dia , Supply, Installation Of Following Sizes Of Hume Pipes For Cable Crossing Of Drains, Roads, Sanitary And Water Supply Lines And The Like, All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. 150Mm Dia , Supply And Erection Of Following Size Of Pvc Trunking Channelincluding Horizontal And Vertical Bends, Joints,Tees, Angles, Cross Members And Other Accessoriess Etc. The Item Including Cost Of Support Clamping At Every 0.6M/1M Intervels As Required For Wall / Floor Mounting System And All Complete Etc. All Complete As Per The Specifications / Drawings Ad Or As Directed By The Engineer. (I) 50 X 80 Mm , (Ii) 50 X 105 Mm , Part-F Diesel Generator Supply, Unloading & Handling, Erection, Testing And Commissioning Of Following Ratings Of Dg Set With Standard Accessories Coupled To Alternator, 3 Phase, 4 Wire, 0.8 Pf (Lag), 415 V Mounted On A Channel Iron Base Frame With Foot Mounting Avm Pads, Fuel Tank (In Built), Charged Battery With Leads, Silencer Along With Exhaust Stack Raised Above Terrace Level(Avg 30M), Composite Type Acoustic Enclosure And Standard Control Panel. The Governor Shall Be Of Electronic & Mechanical Type And The Items Including Erection Of Amf Panel And Complete With Necessary Control Wiring/Cabling, Metering, Indication Lamps And Fixing Accessories Etc. 30Kva , Part-G Ups/Inverter Supply, Erection, Testing And Commissioning Of 1 Phase, 230 V, 1Kva 1P -In 1P Out Ups With Suitable Bcb (Battery Circuit Breaker), Filters, Suitable Tublers Batteries With 30Minutes Backup With Necessary Fixing Accessories Etc. , Supply, Erection, Testing And Commissioning Of 1 Phase, 230 V, 3Kva 1P -In 1P Out Ups With Suitable Bcb (Battery Circuit Breaker), Filters, Suitable Tublers Batteries With 30Minutes Backup With Necessary Fixing Accessories Etc. , Part-H Earthing Supply, Installation, Testing And Commissioning Of Earth Station Comprising Of 50Mm Outer Diameter And 3 Meter Length Of Copper Safe Earth Electrode, Including Approved Clamps, Bolts & Nuts, 450M X 450Mm Brick Masonary Chamber, Heavy Duty Ci Cover, Homogeneous Layers Of Earth Enhancing Backfilling Materials (Bentonite/Fly Ash) Are Placed Around The Earth Pipe As Per Standards (Is 3043), The Items Including Cost Of Excavation, Backfilling Of Earth Etc. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. , Supply, Installation, Testing And Commissioning Of Earth Station Comprising Of 50Mm Dia 3 Meter Long Galvanised Iron Pipe Earth Electrode And 25X3mm Copper Flat, Including Approved Clamps, Bolts, Nuts, Special Backfill Compound (Bentonite/Fly Ash), 450Mm X 450Mm Brick Masonary Chamber, Heavy Duty Rcc / Ci Cover, Drilling Into All Types Of Earth And Rock, Any Excavation And Backfilling, All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. , Supply, Laying, Testing And Commissioning Of Following Sizes Of The Earth Conductors For The Electrical System Which Including Cost Of Supply And Fixing Of Saddles, Insulators, Clamps, Screws, Bolt & Nuts And Providing Earth Work Of 2 Depth, Sleeves Wherever Required Etc., All Complete As Per Specifications, Drawings And/Or As Directed By The Engineer. (I) 25X6mm Hot Dip Gi Flat. , (Ii) 25X3mm Copper Flat. , (Iii) 300Mm Long 25X6mm Hot Dipped Cu Flat. , (Iv) 25X3mm Hot Dip Gi Flat. , (V) 8 Swg Copper Wire. , (Vi) 10 Swg Copper Wire. , Part-I Safety Accessories Supply And Installation Of The Following Safety Accessories To Be Installed In The Electrical Panel Room. First Aid Box. (Is Marked - As Per Standard Requirement) , Supply And Fixing Of 6 Kgs Co2 Type (Isi Marked) Fire Extinguisher Complete With All Clamps And Hardwares Etc. , Supply And Position Of 1.1 Kv Grade 2Mtr X 1Mtr Rubber Mat For Lt Switch Boards To Suit The Switch Board. (As Per Standard & Isi Marked) , Supply And Fixing Of Shock Treatment/First Aid Treatment Chart In Tamil, Hindi And English, Complete With Necessary Fixing Accessories Etc. , Part-J Telephone System Supply And Fixing Of Rj-11Modular Type Outlet Mounted On Suitable Zinc-Passivated Metal Box For Telephone Complete With Metal Box, Front Plate, Screws And Fixing Accessories Etc.,The Item Including Necessary Chipping/Cutting The Wall And Making Good The Same Incase Of Recessed Mounting And All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. , Supply And Fixing Of Rj-45 (Cat-6) Modular Type Outlet Mounted On Suitable Zinc-Passivated Metal Box For Telephone Complete With Metal Box, Front Plate, Screws And Fixing Accessories Etc.,The Item Including Necessary Chipping/Cutting The Wall And Making Good The Same Incase Of Recessed Mounting And All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. , Supply And Laying Of High Quality Cat-6 Ethernet Lan Cable Preferably With Fr Pvc Insulation To Be Laid In Existing Tray/Raceways/ Conduit From Individual Telephone To Network Jack/Switch/Patch Panel/Hub Located In The Communication Room. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. , Supply, Laying And Termination Of Following Sizes Of Telephone Cable Laid In Exitingconduit/Tray/Raceways From Krone Junction Box To Other Krone Junction Box/Epabx Etc.And All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. 2 - Pair Cable , 5 - Pair Cable , Supply And Fixing Of The Following Telephone Krone Type Junction Boxes Enclosed In Ms Box With Hinged Cover With Lock & Key Arrangements Etc.The Item Including Necessary Clamping And Making Good The Same In Case Of Recessed Mounting As Required. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. 5 - Pair Kjb , Part-Kdata Networking System Supply And Fixing Of Rj-45 Modular Type Data Outlet (Cat-6A) Mounted On Suitable Zinc-Passivated Box Complete With Metal Box, Front Plate, Screws And Fixing Accessories Etc.The Item Including Necessary Chipping/Cutting The Wall And Making Good The Same In Case Of Flush Mounting As Required. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. , Supply Andlaying Of High Quality Cat-6A Ethernet Lan Cable Preferably With Fr Pvc Insulation To Be Laid In Exisitng Tray/Conduit/Racewaysfrom Individual Data To Network Jack/Switch/Patch Panel/Hub Located In The Communication Room.All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. , Supply, Laying And Termination Of High Quality Armoured Optical Fiber (48 Fibers) Along With The All Accessories Connectors, Switches Etc , Fixing Of Modular Type Information Outlet (For Wi-Fi) With Necessary Fixing Accessories. The Item Including Necessary Chipping/Cutting The Wall And Making Good The Same In Case Of Flush Mounting As Required. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. , Supply, Laying And Termination Of 6 Pair Fibre Optic Cable Laid In Existing Conduit/Tray/Hume Pipe With The All Necessory Accessories As Required. , Supply, Laying And Termination Of Hdmi Cable Of 15 Meters In Length Laid In Existing Conduit/Tray/Hume Pipe With The All Necessory Accessories As Required. , Supply, Laying And Termination Of Hdmi Cable Of 15 Meters In Length Laid In 40Mm Pvc Pipe With The All Necessory Accessories As Required. , Supply, Fixing , Testing And Commissioning Of 24 Port Switch Patchpanelwith The All Necessory Accessories As Required. , Part-Lclosed Circuit Television System Supply, Laying And Termination Of High Quality Cat-6 Ethernet Lan Cable Preferably With Fr Pvc Insulation To Be Laid In Existing Pvc Pipe From Individual Cctv Camera Outlets To Network Jack/Switch/Patch Panel/Hub Located In The Communication Room. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. , Supplying And Installing Wall Or Ceiling Mounted Outdoor Type Fixed Dome Ip Camera With 1/3” 4Mp Ps Cmos Image Sensor 4Mp@25/30Fps (2560 × 1440), Ir Range Of 30 Mtrs,. The Items Inclluding Necessary Fixing Accessories. , Supplying And Installing Wall Or Ceiling Mounted Indoor Type Fixed Dome Ip Camera With 1/3” 4Mp Ps Cmos Image Sensor 4Mp@25/30Fps (2560 × 1440), Ir Range Of 30 Mtrs,. The Items Inclluding Necessary Fixing Accessories. , Supply, Fixing And Termination Of High Quality Rack Mounted Type Patch Panel With One Number Of 16 Port Poe Network Switch, Fixing Frames, Links And Interconnections, Necessary Accessories Etc., All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. , Supply, Fixing And Termination Of High Quality Floor Mounted Type 6U Floor Mountable Powder Coated Rack With 3X5a Power Manager, 1 Position Fan, Min 1 Nos Of Shelf, Front Glass Double Door With Lock & Key With Suitable Network Port Switch, Fixing Frames, Links And Interconnections, Necessary Accessories Etc., All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. , Supplying And Installing Of 16 Channel Network Video Recorder With Max 320Mbps Incoming Bandwidth Smart H.265+/H.265/ Smart H.264+/H.264/Mjpeg Up To 12Mp Resolution Preview And Playback Support 8 Sata Hdds Up To 10Tb Each, 4 Usb (2 Usb3.0, 2Usb2.0) 2 Hdmi / 2 Vga Simultaneous Video Output Support Multi-Brand Network Cameras Support Raid 0/1/5/10 Mobile Software: Icmob, Gcmob Cms Software: Kvms Pro. The Items Including Supply Of 4Tb Hard Disk, Connectors, Pins And Providing Complete Configuration Etc. , Supplying And Installing Of Power Supply Unit Along With Necessary Battery Backup, Suitable For 1 Nos. 16 Channel Network Video Recorder System. , Supplying And Installing Of 32 Led Colour Monitor. , Part-M-Miscellaneous Liasioning With Tneb Including Submission Of Application & Documents For Obtaining Required Additional Demand Power. (Appx. Cost) , Hvac System Supply, Installation,Gas Charging, Testing And Commissioning Of Modulating Outdoor Units, With Multi Scroll/Rotary Compressorswith One Capacity Controlling Compressor, Special Pre-Coated Fins, Panel, Corrosion Resistant (Suitable For Seaside Installation) Coated Condenser, Inverter Based Condenser Fan Mounted As Indicated In The Drawing, Electrical & Microprocessor Panel, Isolating Valves And All The Necessary Accessories For Proper Functioning Of The Units, Having Following Approximate Capacities. Indicate For All Port Charges, Port Handling Charges, Other Local Duties, Loading, Transportation /Insurance Up To Site, Octroi Charges And All Other Taxes And Incidentals Complete Till Delivered At Site. Customs Duty And Countervailing Dutyfor The Above Imported Equipment. Receiving At Site Above Imported Equipment, Unloading, Storing, Handling Hoisting, Installing In Position, Effecting Connections, Anchoring, Grouting Testing And Commissioning Above Equipment Including Supplying And Installing All Necessary Indigenous Accessories As Required To Complete The Installationnote : Fins And Copper Tubes Of Air Cooled Condenser Alongwith Copper Tubing / Piping With All Joints And U-Bends Exposed To Coastal Areas Corrosive Atmosphere / Aggressive Ambient, Shall Be Painted With Special Orrosion Prevention Coating Either In Factory Or At Site. 14 Hp Odu Units , Supply,Erection, Testing And Commissioning Of Vrf Based Ductable / Fcu Type Indoor Units Complete With Remote And All Accessories,Vibration Isolators & Supports. The Each Indoor Units Shall Be With Potentilal Free Contactor To Connect With Bms. (I) 5.0 Tr With Wired Remote- Ductable , (Ii) Ceiling Mounted Fan Coil Unit - 2.56 Tr With Wired Remote- Fcu , (Iii) Cassette Type Unit - 1.32 Tr With Wireless Remote , (Iv) Hiwall Type Unit - 1.0 Tr With Wireless Remote , Supply, Installation., Testing And Commissioningof Centralized Remote Controller , Supply,Erection , Testing And Commissioning Of All Refrigerant Joints ( Necessary Filling Of Refrigerant Gas In Circuits, Ref. Pipe Pressure Test Etc.). , Supply, Installation, Testing And Commissioning Of Hiwall Splitunit Air Conditioner Comprising Indoor And Out Door Unit Interconected At Field By Refrigerant Piping. The Refrigerant Shall Be Working Onnon Cfc Based R407c/R410 A/R134a Refrigerant. The Indoor Unit Shall Comprise Multirow Dx Cooling Coil, Nylon Pre-Filter, Centrifugal Blower With Drive Motor Mounted In An Aesthetically Pleasing High Quality Plastic Casing. The Out Door Unit Shall Comprise, Rotary / Scroll Compressor/S, Condenser Coil, Propeller Fan, Ip55 Motor All Housed In A Powder Coated Casing. The Fan Shall Be Selected For Low Noise And Shall Be Provided With Fan Guard. The Unit Set Shall Be Supplied With Apower Cum Control Panel Incorporating All Switchgear Required For The Machines Functioning Along With Over Load Relay Etc. The Price Shall Include Corded / Cordless Remote Controler, Installation Of The Units As Per Site Conditions And Charging Of Necessary Refrigerant & Oil If Required. Suitable Contactor To Enable Trip On Receiving Fire Alarm Signal To Be Provided. 1.0 Tr Hiwall Split (Server Room Standby Unit) , Supply, Installation, Testing And Commissioning Ofsoftron Refrigerant Copper Piping With Nitrile Rubber Tubular Insulationwith 13/19Mm Thicknesswith Glass Cloth And Poly Shield Coating Between Indoor To Outdoor Unitsand Supporting Arrangements Etc… Suitable Size For Above Mentioned Dx Hi-Wall Split Units . , Supply, Installation, Testing And Commissioning Of Hard/Soft Drawn Soft Refrigerant Piping Along With Insulation And Supports, Between Indoor & Outdoor Units Duly Insulated As Per Specifications.The Brazing To Be Carried Out With Bleeding Of Nitrogen. The Copper Pipe To Be Insulated With 19 Mm Thick / 13 Mm Thick Nitrile Rubber Sleeves Or Sheet Shall Be Properly Supported With Hanger And Exposed Piping Shall Be Properly Supported In Cable Tray. (I) 41.3 Mm , (Ii) 34.9 Mm , (Iii) 28.6 Mm , (Iv) 22.2 Mm , (V) 19.1 Mm , (Vi) 15.9 Mm , (Vii) 12.7 Mm , (Viii) 9.52 Mm , (Ix) 6.5 Mm , Supply And Laying Of 2C X 1.5 Sqmm. Control Cabling & Earthing As Per Specifications Between Out Door Unit & Indoor Units. The Cables Should Be Cross Linked Polythene Insulated, Armoured Copper Cabling With A Low Smoke And Flame Sheath . Power Supply (3 Phase 415 Volts Will Be Made Available Near Outdoor Units. Contractor To Provide Panel For Onward Power / Control Supply To Outdoor Units Andpower Supply Single Phase Will Be Made Availabe Near Indoor Units Contractor To Provide Power/Control Supply To Indoor Units, Supports, Trays Etc. , Supply And Erection Of 200(W) X 75(H) Size Of Flat Gi Cable Trays Including Horizontal And Vertical Bends, Reducers, Tees, Right Angles, Cross Members And Other Accessoriess Etc. The Item Including Cost Of Steel Support Structures At Every 0.6M/1M Intervels As Required For Suspend From The Ceiling Or Supported From Walls With Ms Suspenders/Brackets And All Complete With Painting/Powder Coating Etc. All Complete As Per The Specifications / Drawings Ad Or As Directed By The Engineer. , Machine Made Gss Ducting With Flanges, Neoprene Gaskets, Factory Made Supports, With Black Painting As Per Specifications (Factory Made With Ductmate Flanges) (I) 24 G Gi Ducts , (Ii) 22 G Gi Ducts , Supply And Installation Of Thermal Insulation 13Mm Thk Closed Cell Nitrile Rubber With Suitable Adhesive As Per Specification , Supply And Installation Of Accoustic Insulation 10Mm Thk Open Cell Nitrile Rubber With Suitable Adhesive As Per Specification , Supply And Installation Of 6 Ht Cont. Al. Powder Coated Grill For Supply And Return Air For Ductable Units , Supply And Installiion Of Gi Collar Damper 600 X150 Mm. , Supply And Installation Of Aluminium Powder Coated 3 Slot Diffuser With Hidden Mist Damper And Fixing Arrangements Etc… , Supply And Installation Of Aluminium Powder Coated Fresh Air Louver With Bird Screenanddamper And Fixing Arrangements Etc… 200 X 200 Mm , Supply And Installation Of Fire Retardant Canvass Connection , Providing And Fixing In Position The Followingupvc Drain Pipes Cut To Required Lengths And Installed With All Screwed Joints, And Providing And Fixing In Position The Necessary Elbows, Tees And Reducers As Per Specifications And Shall Be Insulated With 6Mm Thick Nitrile Rubber. (I) 25 Mm , (Ii) 32 Mm , Supply, Installation, Testing And Commissioning Of Poly Shield Coating With Glass Wool Packing For Weather Proof , Fire Fighting System Supply, Install, Test And Commission Of Boosterpump Terrace Pump Located At Terrace Level, Capacity: 450 Lpm At 35 Mtr. With Pressure Of 3.5Kg / Sq.Cm At The Top Most Hydrant, Complete Head, Horizontal Centrifugal Pump With Bronze Impeller, Ss Shaft, Mechanical Seal,Coupled To 10Hp,2900 Rpm, Tefc, Squirrel Cage Induction Motor Complete Withm.S. Base Frame, Anti Vibration Pad, Foundation Bolts, Pressure Gauge, Pressure Switchwith Drain Valve,And All Other Necessary Fixing Accessories. , Supply, Erection, Testing And Commissioning Ofc Class M.S Heavyfor Downcomer System As Per Is : 1239 For Pipes With Welable Fittings, Valves Necessary, All Structural Supports And Accessories.The Quoted Rate Shall Be Includes One Coat Of Primer And Two Coat Enamel Paint Of Approved Colour And Also Chasing / Chipping Walls Making Bore Hole In Walls / Floor And Making Them Good With Filler Material And Finished In Cement Mortar Etc. Complete In All Respect. (I) 100Mm Nb , (Ii) 80Mm Nb , (Iii) 25Mm Nb , Supply, Erection, Testing Andcommissioning Of `Fire Hose Cabinet (Fhc) In Size Of 750Mm X 900 Mm X 250 Mm.Hinged Door Shutter And Frame And Fabricated Out Of 14 Swg Sheet Steel, Fitted With 4Mm Thick Toughned Glass With Rubber Beeding In The Front Including Finishing With Powder Coat Painting Complete. The Rate Shall Be Inclusive Of Stand For Mounting, All Fasteners Etc, And Cabinet Shall Be Powder Coated Finish Of Red Colour Both Inside And Outside. , Single Headed Hydrant Valve As Per Is 5290, Made Of Gun Metal With 63 Mm Dia Instantaneous Outlet Of 80 Mm Dia Fanged Inelt ,Blank Caps , Chain And Hand Wheels Etc Complete. , 15 M Long, 63Mm Dia Rrl Hose With Instantaneous Couplings And Hoses Shall Be Stored Inside The Hose Cabinet. , 1 No. Gun Short Branch Pipe With Nozzle. , Fire Hose Reel Drum (As Per Isi)Wall Mounted, Swinging Type 18 Swg Ms Sheet, Fitted With 19 Mm Dia X 36 M Long, High Pressure Hose With 5 Mm Outletnozzle With Shut Off Valve (Is: 884-1969) , One No 25Mm Dia Ball Valve , Supply, Fixing, Testing And Commissioning Of Fire Brigade Inlet (Pumping In Breech) Connection, Having Gunmetal Body With 1 Nos. 63 Mm Size Gunmetal Male Instantaneous Inlets (With Nrv), And 100 Mm Size Flanged Outlet, Suitable For Connection To Dry Riser Piping. Fire Brigade Inlet Body Shall Be Provided With Drain Valve. Fire Brigade Inlet Connection Shall Be Isi Approved , Supply, Erection, Testing And Commissioning Of Slimseal Typebutterflyvalves Withshperoidalgraphite Irondisc(Sg Iron), With Nitrile Rubber Sealand Tested Topn 16 Including A Set Of Suitable Gi Flanges, As Per Bs 10 Table - 1, Bolts, Nuts Gi Washers, Neoprene Rubber Gaskets Etc., Complete. 100Mm Nb , Supply, Erection, Testing And Commissioning Of Dual Plate Non-Return Valves With Ci Body &Upto 125Nb Pn 16 Including A Set Of Suitable Ms Flanges, As Per Bs 10 Table - 1, Bolts, Nuts Gi Washers, Neoprene Rubber Gaskets Etc., Complete. 100Mm Nb , Supply, Erection Testing & Commissioning Of Pot Strainer / Y Strainer With Ci Bodytested Topn 16 Including A Set Of Suitable Gi Flanges Rate Shall Include For Rubber Insertion, Bolts, Nuts Msflanges.100Mm Nb , Supply, Erection, Testing And Commissioning Of 25Mm Dia Air Release Valve. The Rate Shall Be Inclusive Of Accessories.25Mm Dia Air Release Valve , Supply, Installation, Testing And Commissioning Of Terrace Fire Pump Panel Withtype-2 Co-Ordination Dol Starters For The Booster Pump And Complete With Auto/Manual Switch, Timers, Rotary Switches, Indication Lamps, Enclosure Being Vermin & Dust Proof (Ip65), Necessary Alarms, Push Buttons, Etc. The Panel Shall Also Be Provided With Industrial Hooter For Alarm And Necessary Suitable Relays Shall Be Provided - 450 Lpm Pump , Automatic Detection And Manual Fire Alarm System Main Control Panel: Supply, Installation, Testing & Commissioning Of Microprocessor Based Intelligent Analogue Addressable, Modular,Expandable, Networkable, 02- Loopfire Alarmcontrol Panel With Minimum 640 Character Lcd Display, Multiple Access Levels, Event History File In Nos.N-Volatile Memory (Eeprom). The Panel Shall Support Programmable Relay For Controlling Lifts, Staircase Pressurizations Fans, Lift Shaft & Lift Lobby Pressurization Fans, Toilets Exhaust Fans, Ventilation Fans At Fire Pump Room, Monitoring Of Fire Hydrant Pump Controlled By Powerful Boolean Logic Equation. The Panel Shall Have 240 Volts Ac Power Supply, Automatic Battery Charger, 24 Volts, Sealed Lead Acid Maintenance Free Batteries Sufficient For 24 Hours Nosrmal Working And Then Be Capable Of Operating The System For 60 Minutes During Emergency Condition. The Panel Shall Be Ul Listed/ Fm Approved. , Supplying, Installing, Testing And Commissioning Of Loop Card , Supplying, Installing, Testing And Commissioning Of Sounder With Strobe Light , Supplying, Installing, Testing And Commissioning Of Addressable Manual Call Point With Back Box. , Supplying, Installing, Testing And Commissioning Of 2C X 1.5 Mm², Armoured, Single Stand, Outer Sheathed, Frls, Pvc Insulated Copper Conductor Cable Confirming To Specified Is Standards . , Supply, Installation, Testing & Commissioning Of The Following: Sensors Confirming To The Description,And Standards. (All Floors& Common Area) Supplying, Installing, Testing And Commissioning Of Addressable Photo Electric Smoke Detector (Optical) With Base, Junction Box And Other Accessories (True Ceiling & Above False Ceiling) , Supplying, Installing, Testing And Commissioning Of Rate Of Rise Heat Detector With Base, Junction Box And Other Accessories. , Supplying, Installing, Testing And Commissioning Of Addressable Photo Electric Multi Sensor Detector (Optical) With Base, Junction Box And Other Accessories. , Analogue Addressable Fault Isolator Module Capable Of Monitoring Shorted Loop Circuit And Automatically Restore Communications When Shorted Conditions Are Corrected , Response Indicator For All Detectors Located Above False Ceiling For Visual Identificaion Of Detector , Supplying, Installing, Testing And Commissioning Of Analogue Addressable Monitor Module (Single Input Module) For Integrating Sprinkler Flow Switch In All Floors And Status Of Fire Pumps With Facp At Ground Floor. , Supplying, Installing, Testing And Commissioning Of Addressable Control Module For Activating The Notification Application Devices. Shall Have Supervisory Facility To Supervise The Auxillary Power Supply As Well As The Notifcation Appliance Circuits..Shall Have Binary Coding Setting Dp Switches, Shall Have An Led Indication Fornormal Working And Active Modes -Approval: Ul Listed , Supplying, Installing, Testing And Commissioning Of Power Supply Unit Which Provides 24V Dc Output For Connecting All Relay Control Modules And Other Modules. The Power Supply Unit Will Be Located In Fire Control Room At Ground Floor And In Designated Location Preferably Near To Fa/Pa Shaft In Typical Floors. , Fire Extinguishers Supplying, Installing And Commissioning Portable Fire Extinguishers Of Following Type & Capacity. (I) Carbon-Di- Oxide Type Fire Extinguisher Of 4.5 Kgs. Capacity, Co2 Gas As Per Is 15222 With Controll Discharge Mechanism Fitted With Hose & Horn Applicable On Class B Fire Rating 21Bconfirming To Is: 15683. , (Ii) Abc Powder Type Fire Extinguisher Of 4 Kgs. Capacity, With Initial Filling (Mono Ammonium Phospate Powder 90) In Brand New Cylinder With Powder Coated Finish, Stored Pressur Type, Pressure Gauge, Controllable Discharge Mechanism With Hose & Nozzle , Confirming To Is:15683. (Abc Dry Chemical Powder- Map 90%) , Signages Providing And Installing In Position The Following Tupe Of Sign Boards Made Out Of 3Mm Thick Opaque Pvc Foam Board With Computer Cut. Pvc Non-Reflective Self Adhesive Vinyle Painted Foam Board, Complete With Mirror Fasteners. Signages With Printed In Case Of Fire, Use Stairs Unless Instructed Otherwise Of 1.5Cm Height Letters In Red With White Back Ground. The Size Of The Board Shall Be 25Cm * 30Cm And Shall Be Fixed At The Height Of 2Mts, From Finished Floor Near Manual Call Points. , Providing And Fixing In Position The Signage Of Incase Of Fire Do Not Use Lift Size 8 X 8 , Providing And Fixing In Position The Signage Of Incase Of Fire Break The Glass To Be Pasted Immediately Above The Every Extinguisher.Size 6 X 6 , Providing And Fixing In Position The Signage Of Fire Extinguisher To Be Pasted Immediately Above The Every Extinguisher.Size 6 X 6 , Providing And Fixing In Position The Signage Of Fire Hydrant & Hose Reel To Be Pasted On Door Of The Every Fire Shaft At All Floors. . Size 6 X 8 , Providing And Fixing In Position The Sign Board Of Assembly Point Complete With 1 Mm Thick Rigid Plastic Board Size Of 600 Mm X 600 Mm To Be Fixed On Ground By Using A Steel Rod / Pipe At Designated. , Providing And Fixing In Position The Signage Of Fire Alarm Panel Size 6 X 6 , Providing And Fixing In Position The Signage Of Exit Signages Glow Type With Battery Backup Size 8 X 16 , Providing And Fixing In Position The Signages Fire Order It Should Contain The Following Matter On 3Mm Thick Opaque Pvc Foam Board Of Computerised Cut, Pvc Non-Reflective Self Adhesive Vinyle Painted Foam Board Of 3 * 4 , Type -I Comprising The Followinga) Alert The Security At Security Room By Actuating Manual Call Point Located At Strategic Locations.B) Evacuate The Occupants By Using Fire Exits And Emergency Exits Only And Assemble At Various Assembly Points.C) If Possible Try To Extinguish The Fire By Using Nearest / Suitable Portable Extinguisher Or Water From Nearest Wet Riser.D) Be Calm And Do Not Give Any Room From Panic, Walk, Do Not Run. E) If You Encounter Serious Difficulty In Evacution, Flat And Try To Attract Attention Of Rescue Team. , Type -Ii Comprising The Following Action By Security / Reception Upon Receipt Of Information Through Fire Alarm Or Fire Detectors Or By Using Public Address System. A) Alert The Occupants By Using Public Address System.B) Inform Fire Control Through Any One Of The Following Phone Numbers: 101, Xxxxxxxxxxxxxxxxxxxxc) Refer Evacution Plan From Evacuating Standard People.D)Guide The Fire Force, On Their Arrival To The Seat Of Fire E) In Case Of The Casualities, Call Ambulance By Dialling Number……………. , Laisoning Works: Laisoning Charges For Works Such As Filling Necessary Applications, Prepration Necessary Drawings And Submitting For Approval With Requestion Form Of Local Fire Force Department, Arranging For Inspection Of Fire Hydrant Installationsand Equipmentsbyfireforce Officers Authority Includiungnecessary Follow - Up Withconcerned Person Uptilloccupation Certifice (Oc) Is Obtained.The Scope Of Work Shall Also Include Depositing The Fees, Other Amounts As And When Required. All The Expense Incurred In Authorities Following - Up In This Regard Shall Be Borne By The Sub - Contrtactor Except For The Payments To Be Made For Only Security Deposit On Pro Rate Basis Etc., Which Will Be Reimbursed On Production Of Original Vouchers. , Lift Works: 2 Stops-Sound Proof 360° Panoramic Glass View Curved Designer Profile No Connector Holes On The Shaft Joints Cylinder Joint Cover - Matching Designer Profile Concealed Hinges With No Projected Visible Metal Cover Invisible Sensors On The Shaft Cabin Colour Matching To Lift Colour Panoramic Frameless Aluminium Door Door Handles Painted To Match Lift Colour Cabin Base Cover Plates Zero Visible Screws On Shaft / Cabin & Doors No Visible Springs On Cabin Basesafety Dual Hcc Brakes (Hardened Cross Compound) Electric Door Lock For Safety Triangle Emergency Alarm Cabin Phone With Gsm Child Safety Switch Cabin Internal Diameter= 1160Mm Height=1930Mm Clear Acess=805Mm Handle=No , Flodable Chair=No Alexa = No Capacity = 240Kg Colour = Cream White Flooring Carpet = Beigelanding Door Floor 0 =F0 Access=Side A Automatic Door Closing Right Hand Side Hinge Floor 1 - F1 Access - Side A Automatic Door Closing Right Hand Side Hinge Shaft External Diameter = 1365Mm Space Requried =1430Mm Color = Cream White Power Reuirementsingle Phase - 230V - 50/60Hz 32Amp With Circuit Breaker Stabilized Power Travel Height From F0 To F1 = 3500Mm Total Travel Height From F0 To F1 = 3500Mm Minimum Headroom Required = 2439Mm
Contract Date : Ref. Documents   |   Contract Value : Ref. Documents
BRR : 10168894 Tender For Construction Of Division Office Building And Misc. Civil Works For Newly Created Office Of Xen (Oandm) At Kathumar Alwar - 1 PART-A 2 1.34Supplying chemical emulsionin sealed containers including delivery as specified. Chlorpyriphos/Lindane emulsifiable concentrate of 20% 3 1.36Diluting and injection Chloropyrifos Emulsifiable concentrate 20% with 1% concentration for PRE-CONSTRUCTIONAL Anti termite treatment as per IS 6313 part III as amended from time to time and creating a continuous chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of wall and floor along the external perimeter of building expansion joints, over the top surface of consolidated earth of which aproch is to be laid surrounding of pipes and conduits etc. complete as per specification (Plinth floor area only shall be measured for payment and excluding the cost of chemical emulsion) . 4 1.8E/W in excavation by mechanical means (hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5m in whichor 10 sqm on plan) including dressingof sidesand ramming of bottoms, lift up to 1.5 m, including taking outthe excavated soil and depositing and refilling of jhiri with watering &ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils. 5 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. (A) 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). (3.1.6) 6 RR stone masonry for with hard stone in foundation and plinth in CSM above 30cm thick wall in CM 1:6 (1cement :6 Sand) (6.1.6) 7 Add extra for Random Rubble stone masonry with hard stone in(A) Wall upto 30cm. and less thickness. (6.3.4) 8 4.1Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix 9 4.9Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. 10 4.2Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcementfor Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.M20 grade Nominal Mix / Design Mix 11 4.3Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcementfor Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.M20 grade Nominal Mix / Design Mix 12 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for :(A) Columns, pillars, posts and struts etc. (4.10.3) 13 (B) Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc. (4.10.2) 14 5.2.2Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in :Cement mortar 1 : 6 (1 cement : 6 coarse sand) 15 Halfbrick masonry in superstructure, above plinth level upto floor V level using bricks of designation 75.Cement mortar 1 : 4 (1 cement : 4 coarse sand) (1cement:6 coarse sand). (5.8.2) 16 6.18.1Supplying and fixing stone lintels/bed plates of approvedquarryroughdressedincement mortar 1:4 :Upto 15 cm. thick. 17 4.13.2Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. (Original producers who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786)Hot rolled deformed bars (IS : 1139). 18 10.17.1Grading roof for water proofing treatment withwater proffing compound Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 19 12.7Finishing with neat cement (punning). 20 10.22Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2coarse sand : 4 stone aggregate 10mm and down gauge) includingfinishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 21 11.26Random rubble dry stone Kharanja under floor. 22 9.5/B-9Providing & fixing T-iron frames for doors, windows and ventilators of mild steel Tee - sections, joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand :6 graded stone aggregate 20mm nominal size ) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as required including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 23 S & F in walls machine cut and polished stone shelves,tands and in 1:3 with machine cut edges:(A) Kota stone minimum 30 mm thick (6.17.3) 24 (B) Sand or other approved stone 25mm thick. (6.17.1) 25 8.13.2.1/B-8Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehydration in glue both sides with approved steel fittings complete as per annexure ‘A’ 30mm thick. Commercial veneer both side. 26 8.14/B-8Extra for providing external lipping with 2ndclass teak wood battens 6 mm minimum depth on all edges of shutters (over all area of door shutter to be measured) Over item no. 8.13. 27 (16.1.1.1)P & F anodized aluminum work (Anodized to be got done from approved Anodiser) for doors, windows, ventilators and partition with extruded built up standard tubelar and other sections of approved make confirming to IS : 733 & IS : 1285 anodised transparent 81 dyed to required shade according to IS : 1868 (Minimum anodic coating of grade AC 15), fixed with rawl plugs and screws or with fixing clips or with expansion hold fasters i/c necessary filling up of gas at junctions, at top , bottom and sides with required PVC / Neoprene felt etc. aluminium section shall be smooth, rust free, straight, mitered and jointed mechanically wherever required i/c cleat angle Aluminium snap beading for glazing/paneling , C.P. brass/stainless steelscrews, Al. Tower bolt & Al. handle & Al. Aldrop etc. all complete as per architectural drawings and the directions of Engineer in charge.(Glazing and paneling to be paid for separately). (a) For fixed Portion.Anodised aluminum (anodised transparent 81 dyed to required shade according to IS : 1868. (Minimum anodic coating of grade AC 15, Anodizing to be got done from approved Anodizer) 28 (b) For shutters of doors, windows and ventilators including P&F hinges / rollers etc. and making provision for fixing of fittings wherever required( locks shall be paid for separately).Anodised aluminum (anodised transparent 81 dyed to required shade according to IS : 1868. (Minimum anodic coating of grade AC 15, Anodizing to be got done from approved Anodizer) (16.1.2.1) 29 16.2Extra for shutters of slidingaluminum windows 30 16.5.2/B-16 P&F glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/Neoprene gasket etc. complete as per the architectural drawings and the direction of Engineer in charge.(Cost of aluminium snap beading shall be paid in basic item.). With glass panes of 5.0mm thickness (weight not less than 13.75 kg/S.pm.) as per IS: 2835. 31 16.11S&f fixed wire gauge of stainless steel of 14 mesh x 24 gauge to the aluminium window by Aluminium beading 20x3mm with suitable screws not exceeding 150mm distance at all heights with all lead and lift with scafolding. 32 8.7 (a)Extra for providing frosted glass panes instead of ordinary float glass panes in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured). 33 16.15Providing and fixing sun control film, thickness of film 1 Mil Visible Light Transmittance 4-24% & Solar Energy Transmittance 42-51% & Total solar Energy rejection 37-43%of approved colour and shade , complete in all respect , at all level , as directed by engineer- in -charge. 34 (16.44.2)Providing and fixing expanded grill made of aluminum as per design and drawing having members section of size 7.5mm x 6.0mm and opening of size 50mmx48mm to aluminum window/vent with required screws, Y and H aluminium section (as per drawing) at the ends and middle joints respectively complete in all respect as per direction of engineer in charge.Powder coating aluminum ( minimum thickness of powdercoating 50 micron) 35 9.10Providing and fixing in position collapsible steel shutters with vertical M.S. Channels 20 x 10 x 2mm and bracket with flat iron diagonals 20 x 5mm. size with top and bottom rail of T-iron 40 x 40 x 6mm. with 40mm dia steel pulleys/ball bearing complete with bolts, nuts locking arrangements inside and outside stoppers, handles etc. as per specification including applying a priming coat of approved steel primer. (To be measured and paid as per outer dimension). 36 16.6.1/B-16P&F double action hydraulic floor spring of approved brand and manufacture to aluminium door shutter confirming to IS : 6315 including cost of cutting floors and cover plate with brass pivot and single piece M.S. With stainless steel cover plate. 37 16.8/B-16 P/F 100mm brass locks for Aluminium door including necessary cuttingand making good etc. complete. 38 16.9.2Providing and fixing aluminium U shape handle of size 100mm with SS screws etc. Complete as per direction of Engineer-in-charge. Powder coated minimum thickness 50 micron aluminium 39 8.26Providing and fixing IS : 3564 marked Aluminium die cast body tubular type universal hydraulic door closer with necessary accessories and screws etc. complete. 40 12.2.2Plaster on new surface on walls in cement sand mortar 1:4 including racking of joint etc. complete fine finished: (A) 20mm thick 41 12.3.2Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finished: (A) 20mm thick 42 (B) 12mm thick (12.3.3) 43 12.5/B-126mm thick cement plaster to celling of mix 1:3 (1 cement : 3 fine sand) 44 7.12Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). 45 7.13Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirmingto IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4). 46 7.5.6(ii)Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete.Rajasthan Black1501 Cm2 to 3600 Cm2 Tiles 47 7.6.2(i)Extra for providing edge moulding to 15-18mm thick marble/ Granite/Kota stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.Granite/Kota Stone WorkFull Edge moulding 48 7.23Providing non slip grooves to granite/ kota stone flooring, counters, vanities etc. using groove cutter V type including machine polishing to groove to give high gloss finish etc. complete as per design approved by engineer in charge 49 7.8Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone workincluding necessaryholesfor pillar taps etc. including rubbing and polishing of cut edges etc. complete 50 7.25.1P & F 1st quality Heavy Duty Vitrified Double Charged tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1: 4 including grounting the joints with white cement and matching pigment etc complete.size600 mm X 600mm 51 (B-11.17.4)Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles includingrubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand)Ordinary cement without any pigment. 52 P & F of double leaf steel shutter for cupboard, the frame is made of pressed steel ISI section 80X25 mm X 1.25mm thick with 1.00mm MS sheet to spot welded including holdfasts of 15X3mm, MS oxidized fittings such as butt hinges, sliding doors bolts, handles, tower bolts & twin peg etc complete including applying priming coat of approved steel primer of red oxide zinc chromate & spray painting in approved shade with deco paint of approved quality complete as per direction of Engineer in charge. (9.39) 53 9.8Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide. 54 9.8.1(A) Extra if square,rectangular hollow tubelarsections are used or grill made by flats only 55 16.56(a)Providing and fixing stainless steel railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).Grade 304 56 13.34.1Making of holein R.C.C. slab/wall/beams and masonary wall (width up to 450 mm) by core cutting machine complete as per direction of EIFromdiameter 100mm to 150mm 57 16.58/B-16 Supplying and fixing Rollor Blinds of good quality and approved make made out of Imported fabric including Roller Mechanism and lock with chain system with all necessary hooks etc. complete as per direction and sample approved by engineer-in-charge. 58 10.33.2Providing & fixing calcium silicate perforated ceiling tiles of size 595 x 595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanised steel sections ( galvanized @ 170 gsm/sqm.) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet spaced at 1200mm center to center and cross “T” of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main “T” at 600mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 21x21x0.30 mm and laying false ceiling tiles of approved texture in the grid including, wherever, required, cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats fixed to ceiling with 6 mm dia and 50mm long dash fasteners, 4mm GI adjustable rods with galvanised level clips spaced at 1200mm center to center along main T, bottom exposed width of 24mm of all T-sections shall be pre-painted with polyester paint, all complete at all heights as per specifications drawings and as directed by Engineer-in-Charge of thickness of tiles as mentioned below:-8 mm thick 59 12.45.1Applying priming coat :With ready mix pink or gray primer of approved brand and manufacture on wood work hard and soft wood. 60 12.46.1 /B-64Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: (A) Two or more coats on new work. 61 12.22.1Providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth complete.New Plastered Surface (three or more coats) 62 12.37.1 /B-12Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding: (A)New work (two or more coats) over and i/c scrapping and priming coat with cement primer. 63 12.42Finishing walls with Acrylic Smooth exterior paint of required shade including all scaffolding New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm ). 64 9.2Structural steel work riveted,bolted or welded in built up sections, trusses and framed work, including cutting, hoisting (height upto 10 m) , fixing in position and applying a priming coat of approved steel primer all complete: 65 12.19Making grooves as per design in plaster 10mm to 20mm wide. 66 (3.8)Providing & fixing precast cement concrete coping 1 : 2 : 4 mix 50mm thick complete as per specification . 67 1.2.2P & F Indian type white glazed vitreous china 1st quality W.C. orissa pan (IS :2556 Mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor: Size 580x440mm. 68 1.3P & F European type white glazed vitreous china 1st quality W.C pan (IS : 2556 Mark) with P or S trap including cutting and making good the wall and floor 69 17.48P/F wall mounted 600mm long grab bar as approveddesign, made of 35mm stainless stell pipe having anti-bacterial Nylon surface with contour finish for better grip. Grab bar should be mounted on wall at height of 800mm from the finish floor level complete in all respect as per Harmonized guidline & Satification of Engineer-in Charges. Make Cera (B2210106) 70 1.7.2P & F water closet Seat Covers with brass hinges complete :Solid PVC (ISI marked) grade-I white for EWC. 71 1.59P & F Jet spray for water closet with C.P. Copper Tube flange of approved make. 72 2.33.5 Providing and fixingSuperior quality CP Brassfittings of approved make as per direction of Engineer-in-charge Two way Bib Cock 15 mm nominal size 73 1.65 P & F C.P. Health Faucet with 1Mtr. Long Tube & Hook of approved make and heavy as per direction of Enginner-in-Charge 74 1.52.1P & F Soap Dish or Tray of approved quality/make C.P. brass 75 1.51.2P & F Toilet Paper Holder with rod of approved quality/make: C.P. brass heavy & Superior quality. 76 1.69.2Providing & Fixing premium qulaity WVC Urinal with PVC waste pipe, dome couplings, concealed iron brackets or screws etc. complete.Flat Back (large) or half stall size 590x375x390 mm. 77 1.16.3P&F Marble Urinal Partition slab both sides polished of approved design cut from marble size 900x600mm.Makrana `Adanga` or Raj Nagar 1St Quality White or Andhi Indo-Italian marble. 78 1.66P & F C.P. brass Urinal Spreader for Large Urinal of heavy duty of approved make as per direction of Enginner-in-Charge 79 1.36.4P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make, P.V.C Waste pipe with PVC nut 32 mm complete including cutting & making good the wall :Size 580 mm x 450 mm 80 1.40P & F 1st quality WVC pedestal for wash basin. 81 (1.38.9.1) P & F Kitchen & Lab. Sink of approved make with C.I. brackets duly painted, 40 mm C.P. waste coupling, C.P. Brass chain with rubber plug, 40 mm G.I. waste pipe up-to floor level complete including cutting and making good the wall & floor :1.0 mm thick stainless steel AISI -304 & IS 13983-1994kitchen sink of approved make as per Engineer-in-chargewith large waste coupling. Overall size 18 x 16 x 6(inches)Bowl size 16x14x6 (inches) 82 P & F Towel Rall or Ring of approved quality/make.C.P. brass Towel Rail with brackets 450x20mm. (1.47.3) 83 2.26.2/S-2P & F PVC Storage Tank ISI Marked (IS : 12701) indicating theBIS license No),of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design: 300 ltr capacity 84 P & F looking Mirrors with P.V.C. frame of approved (Atul, Modi Guard, Saint Gobin or equivalent).Size 500 x 400 mm.(1.45.1) 85 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.,)(A) 20mm nominal size. (2.38.2) 86 (B) 25 mm nominal size (2.38.3) 87 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, this included jointing of pipes & fittings with one step CPVC solvent cement , trenching refilling & testing of joints complete as per direction of Engineer in Charge.(External work).(A) 20mm nominal size (2.39.2) 88 (B) 25 mm nominal size (2.39.3) 89 2.7.3 /S-2P & F Bib cock (IS: 8931 Mark), Superior quality of approved make:(A) C.P. brass bib cock 15mm nominal bore. 90 2.11.1/S-2P & F Ball Cock (IS: 1703 Mark) with Rod & P.V.C. Ball complete: Brass wt. Not less than 300 gm,15mm. 91 P & F Full - way Valve (IS: 778 Mark) or wheel valve of approved make:(A) Gun metal 15 mm nominal bore. (2.15.1) 92 (B) Gun metal 25 mm nominal bore. (2.15.3) 93 1.20.2P & F Low level Flushing Cistern of 10 litres capacity (IS : 2556mark). Of approved make with complete fittings C.I. brackets duly painted, brass ball cock with ball, (IS: 1703 mark) complete including cutting and making good the wall: PVC with PVCbend as per IS : 7231 . 94 2.12.1/S-2P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Gyser etc. C.P. inlet connection 15mm Brass(Is: 8931 marked) 95 P & F 15mm. Dia Connection pipe of approved quality/ make: (A) PVC Pipe with C.P. Brass nuts upto length 450mm.(2.13.3) 96 (3.19.1)Construction of manhole in all type of soil inner size 90 X 60 Cm. 300 mm thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5:10 in foundation, 20 mm thick inside plaster in CM 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring, making channels, 80mm thick stone slab covering with 40mm thick M-15 grade C.C. flooring, Cement cover with frame of 450mm dia, earthwork etc. complete as per design including disposal of surplus earth within 50 mtr. lead. Depth up to 0.5 M 97 3.22.3Construction of soakage well in all type of soil with 300 mm thick dry masonry, top and bottom 300 mm course in CM 1:6, 80mm thick stone slab, jointing of slab in CM 1 : 3, Ralthal, Kharanja, 40 mm thick M-15 grade C.C flooring , earthwork complete as per approved drawing including disposal of earth within a lead of 50 mtr.:Size 240 Cm. dia outside & 240 Cm. depth. 98 3.27.1Construction of septic Tank in all types of soil with 40 Cm .thick masonry in CM 1:6, 15 Cm thick C.C bed of 1:5:10, M-15 gradeC.C floor &RCC slab covering with M15 grade c.c. floor,50 mm thick stone slab partition walls, 20 mm thick plaster in CM 1:6 finished with neat floating cement, 4 Nos stone foot rests of approved design ,two No. 450 mm dia each Ferro cementcover with frame, earth work etc. complete as per approved drawing including disposal of surplus earth within a lead of 50 mtr:-Size 200x100x130 cm.(for 10 users) with 115 mm thick RCC (M-20) slab with Tor steel reinforcement 8mm ϕ @15 cm c/c bothways including shuttering complete in all respect. 99 P & L CC 1:5:10( stone aggregate 40mm nominal size) upto haunches of S.W. pipes including 150mm thick bed concrete ( Width W= Dia of pipe in Cm + 30Cm.) conrete width to be reduced from width W at centre of pipe to 0 at top of pipe(Excluding cost of pipe).100 mm diameter S.W. Pipe.(3.3.1) 100 Construction of chamberin all typeof soli with300 mm. thick masonry in CM 1:6 m 10Cmthick C.C1:5:10 infoundation, 20mm thick inside plaster in CM 1:6, finshed with floatinf neat cenent50 mm thickM-15 grade C.C flooring, Ferro work etc. complete as perdesing includingdisposal of surplus earth within a lead of50 mtr. Inside size 300 X 300 mm depth upto 0.5 M Cement cover with frame.(3.21.1) 101 P & F rigid PVC pipe ( IS: 4985 make) class II/(4 Kg./Cm2). Approved quality /make including jointing the pipe with solvent cement rubber ring and lubricant.(A) 75 mm dia. (3.16.2) 102 (B) 110mm dia. (3.16.3) 103 P & F rigid pvc pipe fittings (IS : 4985 mark) of approved quality / make including joining the pipe with solvent cement rubber ring and lubricant :110 mm dia.(A)Bend 45˚(3.17.8.ii) 104 (B) Bend 87.5˚.(3.17.9.ii) 105 (C) Vent Cowel (3.17.12.ii) 106 (D) Plain Tee (3.17.3 (ii)) 107 (E) Door Tee (3.17.4 (ii)) 108 (F) Gully trap (3.17.27) 109 Supply & Fixing G.I. Union ISI marked in G.I pipes line as required complete in all respect of size . (A)15 mm dia nominal bore B Class. (2.32.1) 110 (B)25 mm dia nominal bore B Class. (2.32.3) 111 P & F Grating of approved quality/ make Stainless steel sheet size 125 mm dia. (1.48.1) 112 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR. (A) Short point (up to 3 mtr.) (1.1.1) 113 (B) Medium point (up to 6 mtr.) (1.1.2) 114 © Long point(up to 10 mtr.) (1.1.3) 115 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR On board (1.3.1) 116 Providing and fixing of power plug point with non modular accessories as per PWD specification for electrical Works withGalvanized box of 1.2 mm thickwith earth terminal with suitable size phenolic laminated sheet (IS : 2036 -1995) cover including cost of 16 amp. Switch (IS :3854) and 3/6 pin 16 amp. socket outletmaking connection , testing , etc. as required. . For specification ofWiring accessories refer ChapterE - 07 related item &For additional technical parameters of product / work refer Annexure A attached with this BSR (7.36) 117 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR(A) 2 x 2.5 sq. mm. + 1x1.5sqmm (4.1.7) 118 (B) 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. (4.1.14) 119 Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles,making connection with GI/Cu purity purity >95%thimble etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 8 SWG G.I. ( Hot Dipped) Wire. (14.6.8) 120 14.2Plate Earthingas per IS:3043 with Hot dipped G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying3 to 4 mtr. below the ground level with 20mm dia. G.I. B class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. and embodying the pipecomplete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 121 Providing & Fixing of energy efficient direct fit (Retrofit)Polycarbonate/ GlasshousingSMD Mid Power LED tube rod(with integral driver & alumn. heat sink ), on existing fixture.system lumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.≥0.95,CRI >80 , life time of minimum35000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 1200mm , Min. Lumens output 2000 lmLED Tube rod with Polycarbonate Housing. (17.2.2) 122 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .20 mm Dia. (18.18.1) 123 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR. (5.9) 124 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR. Single pole MCB (With B/C curve tripping Characteristics). 6 A to 32 A rating. (6.1.1.2) 125 Providing & Fixing of 240/415 V isolatorISI marked IS:13947-III/conforming to IEC 60947-3, suitable for AC22A utilization category, 4KV impulse withstand voltage,true contact indication,Red colour dolly / lever shall have single mould covering over all poles for operation , two position din rail mounting,minimum phase termination capacity of 35sq.mm.IP 20 contact protection and fitted in existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR. Four pole Isolator. 63 A rating. (6.2.3.2) 126 6.10.3.4Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR.Metal door (Three phase) IK-09 and IP-43with Metal end box.12 Way 127 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR(A) 6.0 Sq. mm 2 core. (11.2.2.1) 128 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .(A)LED Street Light fixture with Minimum lumen output 11225 lm. (18.12.6) 129 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 6 kg. (24.67.3) 130 Providing & Fixing ofISI marked (IS:371) 6 amp surface type 3 pin ceiling rose with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screws including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .(7.12) 131 Providing & Fixing of ISI marked (IS:1258) batten/angle lampholder with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screwsincluding making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .(7.13) 132 Providing & Fixing of IS 11037:1984marked non modular socket size flush type 120 watt rotary minimum 5 step fan regulator with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .(7.20) 133 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) (15.7.1) 134 15.11.2Providing & Fixing ofof Double ball bearing, copper wounded capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 300 mm sweep 135 Providing & Fixing of IP20, 2x2 LED Surface/ Recessedmounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 ,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .(A) Recessed MountingMinimum lumen output 4200 lm. (17.4.1.3) 136 (B) Surface MoutningMinimum lumen output 4200 lm. (17.4.2.3) 137 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing.OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Surface Mounting (with extruded alumn. Housing )(A) Minimumlumen output 650 lm. (17.3.2.1) 138 (B) Minimum lumen output 1300 lm. (17.3.2.2) 139 7.26Providing & Fixing of ding dong/musical chime bell as per PWD specification for electrical Works, including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 140 7.27.3Providing & Fixing of modular type switch/ bell push duly ISI marked (IS :3854) with CM/L no. printed and made out of unbreakable and fire retardant vergin UV Stabilized Polycarbonatewith brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,minimum width ofswitch toggle( PUSH PART ) should not less then 20mm,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR. 10 A bell push 141 20.1Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 142 20.5.1Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Single Aperture 143 20.4.1Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Cat 6, Un-sheilded Information Outlet 144 20.6.2Supply, Installation, Testing and Comissioning of Rack mounted 19 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panelswith Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Modular Patch Panel Loaded with Cat -6A I/O 145 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord(A) 2 Mtr . (20.7.1.3) 146 (B) 3 Mtr (20.7.1.4) 147 20.16.4Supply & Installation of IP-20 & IK-08 , UL ListedWall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with UMarking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. Accessories like: 1 No of 19 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastneretc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .15 U Rack with Width 600 mm & Depth 400 mm + 100 mm 148 20.18.2Supply , Installation, Testing and Comissioning ofUnmanaged Switch Plug-and-play - easy setup with no configuration or no software needed, following Port fast ethernet - 8 port 10/100 MBPS auto-negotiation RJ45 ports,IEEE 802.3x flow control ,supports auto-MDI/MDIX, eliminating the need for crossover cables including making connection etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .24 Port 149 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR.(A) 32 mm. (1.4.3) 150 (B) 20 mm. (1.4.1) 151 (2.2.1) Construction of Tube Well from ground level and upto 100 mtr. depthto accommodate housing and assembly pipe in all type of alluvium strata, unconsolidated formation such as pebbles, boulders etc. by percussion/ rotary drilling methodas per IS:2800 Part 1: 1991 andIS:2800 Part II: 1979 (both amended upto date) and technical specifications for removal of overburden. The work includes the cost oflowering of casing pipe, but excludes the cost of casingpipe. Nominal bore 200 mm dia. 152 Construction of tube well after completion of drilling by rotary /percussion method & upto 100 mtr. depthin all type of rocks by DTH systemas per IS:2800 Part 1: 1991 andIS:2800 Part II: 1979 (both amended upto date) and technical specifications. The workshall be deemed completed only after obtaining sand free water. The bore well should have a throughout nominal size bore beyond casing pipe.Nominal bore 150 mm dia. (P 2.3.1) 153 (B) Add 15% extra on above item (Item No 2.3.1 to 2.3.3) for drilling depth beyond 100 mtr and up to 200 mtr from ground level, rate shall be applicable for only extra depth beyond 100 mtr and up to 200 mtr. (P 2.3.4) 154 (E-112/21.2.2.1)Supply & fixing of PVC threaded casing pipes for Tube well (IS 12818:1992) of3mtr. Each for depth up to 1200 ft. Plain and strainer Casing CS for Depth upto 400ft. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . more than400 ft to 1200 ft. Depth 40mm dia 155 Supply & Fixing M S clamp set of 50x6 mm flat from iron with nuts and bolts etc for holding the riser pipe assembly of submersible pump set. (P 2.22) 156 (4.8.4)S & F tube well cover of M.S.sheet (6mm thick) with nuts and boltscomplete for casing size:200mm dia Nominal bore 157 Supply & Fixing of ISI marked three core PVC flat submersible cableas per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980including making connection etc. 3 core 6.0 Sq.mm (P 2.19.2) 158 (E-112/21.3.2)Providing & Laying of Polypropylene rope Confirming to IS:5175 for submersible pump of following sizes. complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .16mm (suitable above 50mm & up to 75mm OD pipe) 159 Supply of ERW M.S. black casing pipe ISI marked (IS: 4270/2001) or amended up to dateoffollowing sizes. 200 mm dia NB (Thickness of pipe 5.4mm & mass of tube 28.46 Kg/m) (P 2.11.2) 160 Labour charges for making slots on blank pipes made of ERW MS black pipe ISI marked of following sizes, the slotting should be as per IS:8110-1985. 200 mm dia nominal bore of 5.4mm thickness. (P 2.12.3) 161 21.6.1.4SITC of Radial / mixed flow ISI marked water and anti-corrosive liquid filled submersible motor pump setssuitable for 100/150mm dia borewell.The size of adopter fixed on top of the motor should exceed the top of coupler , for safegaurd the coupler. The construction material of motor and pump should match IS: 8034 : 2018 and IS: 9283 guideline. The radial flow pumpset should operate at 5 star energy efficiency level of BEE and mixed flow pump set should operate at 3 star energy level of BEE, accompained by valid BEE certificate. Motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008,& IS12615:2011with required accessories including making connection suitable for Bore well. The job includes labour part of lowering ofriser pipe G.I./H.D.P.E. with rope, cables & pump, installation of complete fitting and accessories, jointing of electrical cables up to Starter. All labour for testing of submersible pumps set and supply of water to water mains, complete in all respect. OEM shall have submitNABL / CPRI / ERDA accrediatedlab type test certificate before execution. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .100 mm diameter Submersible pump shall have following HP Rating, phase, Head range, Discharge range respectively. 3.0 HP, 1-Ø, (40 -170)Mtr, (60- 20) LPM Copper Wound 162 21.13.1.2SITC of ContactorOEM Fabricated DOL/Star-Delta Starter panel with switchgear selection as per Type-2 Cordinatiom Chart andmade out from 1.6 mm thick powder coated CRCA sheet, enclosure comprising of over load protection relay, short circuit & single phasing protection, Illuminated ON / OFFpush buttons,ammeter, voltmeter, indicating lamps etc.suitable for following rating motors complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . For single phase Submersible / Monoblockpump. 2.0 HP to 3.0 HP (DOL starter) 163 (R-34/7.16.2.5)Providing and erecting direction and place identification retro-reflectorised sign asper IRC:67 made of high intensity grade sheeting exclusive of lettering, border and signs fixed over aluminium sheeting, 2mm thick fixed on a mild steel angle iron frame 50mmx50mmx6mm supported on mild steel angle iron post 75x75x6mm upto the top of sign board, length of post from bottom of sign board is 2.85m upto foundation level post duly painted in black and white synthetic enamel alternate ship 30cm wide fixed to the ground by means properly designed foundation with M-15 grade cement concrete 45cmx45cmx60cm, 60cm below ground level as per approved drawing and as per MORTH specifications clause 801 Double angle post 120cm x 90cm
Contract Date : Ref. Documents   |   Contract Value : Ref. Documents
Disclaimer

We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.

Tender Detail
Website https://etender.cpwd.gov.in/login.html
Quantity
MSME Exemption No
Tender Type Open Tender
Startup Exemption Click Here
Competitive Bidding NCB
Similar Tenders
TENDER INSIGHTS

858

Electric Tenders
Live
CLICK TO KNOW MAXIMUM WIN

Tell us about your Product / Services,

We will Find Tenders for you

🇮🇳 +91
TenderDetail
Loading tenders