TDR : 56379228
Central Public Works Department

Tender Brief :

Delhi, Delhi

Annual Repair And Maintenance Of To South Block, New Delhi Dg.2026-27 (Sh: Shifting Of Office Furniture, Electrical / Electronic Items, Documents And Other Store Materials From / To South Block And Other Office Buildings In Lutyen Zone, New Delhi From / T

Published: 08 Jul 2026
Opening: 16 Jul 2026
Closing: 16 Jul 2026
Amount: 8.79 Lakhs
EMD: 17584
Tender Fee: Ref. Documents


Services Acid Storage Tank Active Harmonic Filter Actuator Aerial Cable Aerobridge
4
Days Left
Tender Summary / Eligibility Criteria
Annual Repair And Maintenance Of To South Block, New Delhi Dg.2026-27 (Sh: Shifting Of Office Furniture, Electrical / Electronic Items, Documents And Other Store Materials From / To South Block And Other Office Buildings In Lutyen Zone, New Delhi From / To New Seva Teerth Complex).
Documents Download All
6a82ddbd-b7c6-4903-89ad-89374ec497fb
6a82ddbd-b7c6-4903-89ad-89374ec497fb.html
DocumentsList
DocumentsList.zip
No Boq
No Corrigendum
Probable Bidders

AI engine predicts probable bidders to help you bid strategically.

MSME Exception
Explore More →
Technical
Tender involves procurement of high capacity electrical equipment including diaphragm coupling of pump & motor with 90kW capacity at 2900 RPM. The project scope includes installation, testing, commissioning and operational handover.
Previous / Similar Result
BRR : 1242497 Environment Protection And Resource Management ( Housekeeping ) Works At Lpg Bottling Plant , Sarpara , Section A: Environment Protection Jobs: A ) The Job Includes Sweeping , Cleaning , Washing , Dusting Of Floor , Roofs & Walls , Removal Of Cobwebs In Admn . Building , S&D Block , Canteen , Fire Pump House , Sub-Station Building , Workersamenity Block , Club Room , Stores , Security Room And The Toilet , Bathroom Attached With The Above Buildings On Daily Basis . The Job Includes Cleaning Of Floors Of All The Above Buildings By Wet Cloth & Phenyl , Dusting And Cleaning Of Glass Doors And Windows , Office Furniture , Table Chairs , Racks , Cup-Boardss , Almirah Dustbins , Fans , Switch-Boards , Name Boards Etc On Daily Basis . The Job Also Includes Cleaning And Washing Of All Urinals , Toilets/Bathrooms , Wash Basins Wherever Provided In The Plant On Daily Basis . All Required Cleaning Items Like Phenyl , Acids , Herpic , Naphthalene Balls Etc . & All Equiments/Materials Required For Such Cleaning Activities Such Brush , Brooms , Cloth Etc Will Be Provided By The Contractor . B ) Sweeping , Cleaning Of Drivers Rest Room , Home Guard Barrack & All The Toilets At Tt Parking Area On Daily Basis . All The Cleaning Materials/Equipments Described In Item No: 1 Are To Be Provided By The Contractor . , Cleaning Of Roads In Licenced , Un-Licenced And Buffer Zone Area Including Cleaning Of Truck Parking Area And Disposing Off Collected Sludge , Dirt Etc At Nominated Place Within Plant/Outside As Per Direction On Daily Basis . , A ) Removing Of Grass/Shrubs And Such Unwanted Vegetation By Cutting/Uprooting As Required , Trimming Of Trees As Per Direction Anywhere Within The Plant Premise , Buffer Zone Road And Tt Parking Area . Including Collecting /Carrying And Disposing Them As Directed On Daily Basis . All Equipments For The Job Will Be Provided By The Contractor . B ) Repair And Maintenance Including Cost Of Lubes . Oil For Grass Cutting Machine Of The Contractor , A ) To Carry Out Necessary Job For Maintaining All The Gardens In Plant Premise On Daily Basis And Plantation Of Tree/Flower Sapling Withing Plant Premise As & When Directed . All Equipments For The Job Will Be Provided By The Contractor . B ) Cleaning Of Drains Inside The Plant Premise And Tt Parking Area Except The Drain Around Filling Shed & Product Pump House . The Job Includes Removal Of Mud/Sludge/Muck Etc Collected In Drain And Disposing The Same At Nominatd Place As Directed . The Arrangement Of Lifting Ang Shifting The Sludge/Mud Will Be Provided By The Contractor . C ) Cleaning Of Service Water Tank Including Underground Tank Of Service Water Treatment Plant After Close Of Operation Or On Sunday /Holiday As And When Directed . The Job Includes Emptying Of Tank , Removal Of Green Moss , Scrapping Of Surface By Wire Brush , Washing By Fresh Water And Finally Filling It By Fresh Water . Brushes & Brooms Required For The Job Will Be Supplied By The Contractor . D ) Opening/Cleaning/Closing Of All The Soak Pits/Septic Tanks Of The Plant Including Disposal Of Mud As & When Required/Directed Within The Plant Premise & In The Tt Parking Area , Section B:Resource Management Job:A ) Collecting Documents/Courier From Plant , Depositing The Same At Sbi , Post Office , Courier Office And Other Offices Within Guwahati City As & When Required . The Job Includes Resource Management At Accounts Deptt . Offfice Of The Plant . All Expenditure Like Conveyance Etc . For The Job Will Have To Be Borne By The Contractor . B ) The Job Includes Arranging & Maintaining Office Files As Per Direction Of Plant Officials On Daily Baisis . , Resource Management At S&D Building ( To Be Performed In Two Shifts From 6 Am To 10 Pm ) A ) Sorting Of Challans , Removing Of Carbon , Arranging Them For Proper Distribution/Despatch And Filling The Letters/Documents/Challan/Crs Etc In Serial Order In The Office Premses , Maintaining Proper Records For Despatch To Different Places On Daily Basis As Per Direction . Also Including Work Done On Sundays In Both The Shifts .
Contract Date : 25 Oct, 2021   |   Contract Value : 36.51 Lakhs
BRR : 1801917 Tender For Haulage, Clearing, Cartage And Miscellaneous Work Satindanel Pg Bottling Plant , At Gidha For A Period Of One Year And Extendable To Another Two Years On Yearly Basis At Same Rate, Terms & Condition On Mutual Consent Basis -Segregation Of Cylinders Meant For Statutory Testing By Reading The Date On The Vertical Stay Plate / Hot Repairable / Irrepairable For Deshaping By Visual Inspection And Stacking The Cylinders Of Different Category That Is Due For St, Due For Hot Repair, Irrepairable, Omc, Spurious Etc. At Nominated Place In Vertical Stacksas Per Instructions For Both The Carousel Stream 2 De-Caping / Opening Of Safety Caps From The Cylinders Valve. Broken / Damaged / Safety Caps To Be Removed . Job Includes Collection Of Defective Safety Caps I.E. With Damaged Threads And R.S. Clips And Sound Safety Caps Which Are Not Tied With Vertical Stay.The Job Is For Both The Carousel Stream 3 Checking Cylinders Valves For Presence Of ‘O’ Ring Cylinders On Conveyor And Stacking Of The Same On Plant Floor As Directed And Fixing Of New ‘O’ Ring In The Valve With Coropration Supplied ‘O’ Ring Fixing Tool As Directed.The Job Is For Both The Carousel Stream. 4 Tying And Fixingof Safety Caps With Incoming Streams Of Cylinders By Looping The Threads With One Of The Vertical Stay. The Caps Are To Be Tied With The Cylinders, Which Are Not Having Safety Caps Tied With Vertical Stay. To Avoid The Damage, Safety Caps Are To Be Hanged Around Sc Valve Of The Cylinder.The Job Is For Both The Carousel Stream. 5 Replacement Of O-Ring In O-Ring Missing Cylinders Detected By O-Ring Detector In Both The Carousel Line In Correction Loop, Passing These Into Main Stream .Also Diverting Valve Defect Cylinders Detected By Vd Machines Towards Evacuation Unit Through Conveyor. 6 Replacement Of Defective Valve In Valve Defective Cylinders Detected By Eld M / C In Both The Carousel Line In Correction Loop / In Vcwe M / C, Passing These Into Main Stream .Also Diverting Valve Defect Cylinders Detected By Vd Machines Towards Vcwe M / C Through Conveyor. 7 Placing Of Pvc Seal On Cylinders In Motion On Conveyor. Seal Should Be Tight / Striaght Enough To Enable Sealing. 8 Sealing Of Those Filled Cylinders Which Are Not Sealed With Automatic Sealing Unit Or, Are Improperly Sealed On Moving Conveyor By Mechanical Crimper / Portable Hot Air Sealing System On The Output Conveyor Manually. Necessary Tool Shall Be Supplied By Corporation. The Job Includes Removal Of Seal Of Improperly Sealed Cylinders And Placement Of Safety Cap, Pvc Seal On To The Valve, If Not Available. 9 Replacement Of Defective Sc Valve After Evacuation Of Valve Defect Cylinders In Valve Change Machine With Proper Torque.The Job Includes Supervising Depressuring Of Cylinder, Putting Teflon Tap In Valve Thread Etc As Per Direction. 10 Repair Of Cylinders With Bend Vertical Stay By Straightening The Same With The Help Of Hydraulic ( Vp Ring / Foot Ring Straightening Mc ) / Mechanical Machines / Manual Jacks As Directed. The Job Includes All Handling Involved In The Operation, Such As Stacking, Desatcking, Offloading From Conveyor And Loading Onto The Conveyor. 11 Topping Up Of Soap Solution Trays For Various Chain Conveyors During Operation. The Job Includes Shifting Of Soap Drum From Stores To Plant At Nominated Place, Preparation Of Soap Solution In 1:10 Ratio Or As Directed, By Manual Stirring Or By Mechanical Strirrer And Carrying The Soap Solution Through Pipeline / In Contractor Supplied Buckets For Topping Up The Soap Solution Trays. It Should Be Ensured That All Trays Are Always Found In Topped Up Condition.Approximate No. Of Trays - 150.This Job Includes Return Back Of Empty Cain Kote Drums From Shed / Yard To Nominated Scrap Yard As Directed. 12 Handling Of Cylinder To Avoid Toppling / Jamming On Conveyor Due To Damage Footring Or Due To Any Other Reason Including Operation Of On / Off Switches Of Coveyor. 13 Retrieval Of Safety Caps From Various Places In And Around The Plant, Handing Over To Stores In 100 Caps Bunch After Removing Seal. Washing And Repairing Of Defective Caps By Replacing Threads And S.S. Clips As Directed. ( S.S. Clips And Nylon Threads Will Be Provided By Corporation. Payment Will Be Made For Fit Safety Caps Deposited To Stores / Plant ) . 1 Bunch Of 100 Caps Will Be Considered As 1 No. Unit. 14 Destacking Of Empty Cylinders From The Stacks On Plant Floor And Putting Them On Conveyor At Any Stage Including Shifting By Trollies Or, Mannually. No Belly Rolling Of Cylinders Is Permitted. 15 Cylinder Size 14.2 Kg / 19 Kg 16 Cylinder Size 5 Kg 17 Cylinder Size 47.5 Kg 18 Cylinder Size 425 / 450 Kg 19 Destacking Of Filled Cylinders From The Stacks On Plant Floor And Putting Them On Conveyor At Any Stage Including Shfting By Trollies Or, Mannually Irrespective Of Crossing Any Number Of Chain Conveyors. 20 Cylinder Size 5 Kg 21 Cylinder Size 14.2 Kg / 19 Kg 22 Cylinder Size 47.5 Kg 23 Cylinder Size 425 / 450 Kg 24 Stacking Of Empty Cylinders By Removing Them From Chain Conveyor At A Nominated Place In Stacks Including Shifting By Trollies, Or Manually Irrespective Of Crossing Any Number Of Chain Conveyors. 25 Cylinder Size 5 Kg 26 Cylinder Size 14.2 Kg / 19 Kg 27 Cylinder Size 47.5 Kg 28 Cylinder Size 425 / 450 Kg 29 Stacking Of Filled Cylinders By Removing Them From Chain Conveyor At A Nominated Place In Stacks Including Shifting By Trollies, Or Manually Irrespective Of Crossing Any Number Of Chain Conveyors. 30 Cylinder Size 5 Kg 31 Cylinder Size 14.2 Kg / 19 Kg 32 Cylinder Size 47.5 Kg 33 Cylinder Size 425 / 450 Kg 34 Shifting Of Empty Cylinders / New Cylinders / Hot Repaired / Retested Cylinders From Anywhere Within Plant Sheds, Including Stacking / Destacking Crossing Any Number Of Chain Conveyors By Using Trollies / Manually As Directed. 35 Cylinder Size 5 Kg 36 Cylinder Size 14.2 Kg / 19 Kg 37 Cylinder Size 47.5 Kg 38 Cylinder Size 425 / 450 Kg 39 Shifting Of Filled Cylinders From Anywhere Within Plant Sheds Including Stacking / Destacking Crossing Any Number Of Chain Conveyors. 40 Cylinder Size 5 Kg 41 Cylinder Size 14.2 Kg / 19 Kg 42 Cylinder Size 47.5 Kg 43 Cylinder Size 425 / 450 Kg 44 Fixing Of Corporation Supplied Stickers. Neck Lables Etc. On Cylinders At A Place As Directed After Cleaning The Surface With Wet Cloth Which Will Be Supplied By The Contractor. 45 Cleaning Of Water Bath On Daily Basis At The End Of The Day And As Directed. The Job Includes Emptying Of Water Bath, Cleaning Of Mud, Dirt Etc., Cleaning Of Inner Surface Of Water Bath By Using Wire Brush And Suitable Detergant And Cloth And Washing Of Water Bath By Fresh Water And Finally Topping Up With Fresh Water. Brush, Cloth And Pvc Pipe To Be Provided By Contractor. 46 Sweeping Floors Of Filling / Empty / Filled / Valve Change Sheds On Daily Basis During The Shift, Disposing Of Accumulated Dirt, Dust, Muck Etc In A Nominated Place As Directed On Shift Basis. The Item Also Include Cleaning Of Drinking Water Basins In Shed Area. 47 Cleaning Of One No. Of Washing Unit Tank / Pit Daily Including Removal Of Mud / Dirt Etc. 48 Opening Of Valve Slip Cylinders. The Job Includes Opening Of Round Off Valves By Special Hand Tools / Wrenches Etc. Provided By Contractor. The Item Also Includes Stacking / Destacking Shifting And Handling Of Cylinders. ( The Payment Will Be Made For Only Those Of Which Valve Is Opened ) . 49 Providing Assistance In At S&D In Each Of Working Shift For Storing , Collection, Arranging The Documents Which Includes Maintaining Co-Ordination With Filling Shed, Security Gates, For Collection / Despatch Of Documents 50 Providing Assistance At S&D In Each Of Working Shift For Preparation Of On-Line Way Bill For Packed Trucks, Bulk Trucks, Other Incoming Materials Like New Cyls, Dpr, Consumables Etc 51 Providing Assistance To Accounts And Pm Section Section For Different It Related / Clerical Jobs 52 Collecting Documentsfrom Location, Depositing The Relevent Documents At Sbi Or Any Other Bank As Well As Other Offices Like Factory Inspector Office , Dm Office, Etc. Against Acknowledgement As Specified.Submitting The Acknowledgement On The Same Day At The Location. This Includes The Collection / Delivery Of Any Documents From Plant To Local Ioc Offices Etc. 53 Collection Of Various Documents From Directed Places In The Plant ( S&D, Filling Shed & Admn. Bldg. Etc. ) & Arranging Them In Serial Order As Directed, Binding The Same & Placing In Record Room As Directed. 54 Serving Tea / Cofee / Snacks Etc For Guests At Plant ManagerS Section .Materials To Be Provided By Corporation. 55 Providing Assistance For Record Keeping In Maintenance Store For Proper Record Keeping Of Receipt / Issue Of Materials From / To Plant And Within Plant As Per Direction 56 Valve Retrieval – The Job Includes The Retrievalthroughvalve Retrival Machine As Per The Direction Of Plant In Charge.The Job Includes Bringing Of Old / Defective Valves From Stores And Segregation, Painting Of Colour Mark On Retrieved Valve And Depositing Both Retrieved And Defective Valves In The Stores, Compressed Air, Kerosene, Testing Equipments And Facilities Will Be Provided By Corporation. Payment Will Be Made For Actual No Of Valves Retrieved 57 Upkeep And Dusting Of Floor, Roofs And Walls, Removal Of Cob Webs Of The Building Blocks And Bath Room, Water Cooler Room Etc. The Job Includes Cleaning Of Floor By Wet Cloth And Phenyl / Dettol, Dusting And Cleaning Of Glass Doors, Office Furniture, Table, Chairs, Racks, Cupboards, Almirah, Dust Bins, Etc, On Daily Basis. . All Required Items Like Phenyle, Acids, Brooms, Natphalene Balls, Cloth Etc. Will Be Provided By Contractor.The Areas Include Administrative Block, S&D Block, Watchman Cabin, Canteen, Workers Amenity Block, Club Room, Stores, Main Gate, Drivers Rest Rooms, Security Rest Rooms, Frisking Gate Etc. 58 Cleaning / Maintaining DriverS Rest Room Incldg Toilets , Contract WorkerS Rest Room / Toilets . 59 Maintaining Of All Lawns & Flower Plants & Earthen Pots As Directed In Plant.The Job Includesregular Watering Of Lawn & Flower Pots, Plants And Earthen Pots, Changing Of Soil And Manuring. Trimming Of Unwanted Branches, Removal Of Weeds & Cutting Of Grass Pof Lawn On Day To Day Basis. Manure, Plant Sapplings, Seeds, Flowe Pots, Hose Pipes For Watering Witt Be Provided By The Corporation. 60 Cleaning Of All Soap Soultion Trays Every Week The Job Includes Removal Of Soap Trays From Conveyor, Removal Of Muck, Mud And Sludge From Trays, Cleaning With Non-Ferrous Brush And Washign With Fresh Water The Sludge, Muck, Mud Removed From Trays Is To Be Disposed Off At Designated Place As Directed.The Job Also Includes Preparation Of Soap Solution In 1:10 Ratio Or As Directed And Filling Of Trays With Fresh Soap Solution Prepared. Wire Brush And Other Materials Required For Cleaning Will Be Provided By Contractor. 61 Washing Of All Sheds With Water On Weekly Basis Including Removal Of All Mud, Dusts Etc 62 Cleaning Of All Chain Conveyor Channels With Jet Water Using Hose Pipes And Cleaning All Accumulated Dusts, Muds Etc In The Channel, Removal Of All Unwanted Materials . After Cleaning Chain Conveyor Will Be Run With Soap Sloution Carried To The Channel By Running The Drive Units 63 Upkeep Of All Roads In Licensed, Unlicensed And Buffer Zone Area Including Cleaning Of Truck Parking Area, Sweeping Of Roads, Paved Area, Unpaved Area On Weekly Basis And Disposing Of Collected Muck / Sludge, Dirt Etc. At Nominated Place Within The Plant / Outside, As Directed. 64 Upkeepingof Facilities With Removal Of Cob Webs From Roofs, Pillers, Structures, On Weekly Basis, Disposing Of Accumulated Dirt, Dust, Muck Etc In A Nominated Place As Directed. The Job Also Includes Cleaning Of All Machines, Equipments In All The Sheds 65 Spray Of Pesticides / Weedicides In Office Buildings, All Plant Sheds, Cr. Shed, Stores, Workers Amenity Block, S & D, Watchman Cabin, Dg & Pmcc And Fire Pump House And Surroundings Area In The Plant ( Raw Material, Spray Machine Will Be Provided By Corporation ) . 66 Shifting Of Cylinders From Ground To Plant Floor Or Vice Versa Through Truck / Tractor / Trolley / Manually As Suitable.It Includes Stacking / Destacking, Loading / Unloading And Handling. 67 Stencilling Of Cylinders With Appropriate Fix Letterings, After Properly Preparing The Surface By Cleaning With Non Ferrous Wire Brush, Removing Dirt Etc. With Quick Drying Synthetic Enamel Paint Of Appropriate Colour And Approved Make And Quality. The Paintbrush And Stencils ( Size Approved By Plant ) Will Be Provided By Contractor. The Item Also Includes Stacking / Destacking Shifting And Handling Of Cylinders Required For Stenciling. This Job Is For All Type Of Lpg Cylinders ( 14.2 Kg / 19.0 Kg / 5.0 Kg / 47.5 Kg ) .The Different Categories Are As Under : 68 Tareweight Letter Sizes 40 Mm With Black Paint At 3 Places On Cylinders. 69 Net Weight 14.2 Kgs. With Black Paint In One Place With 20 Mmx3 Mm Letter Size. 70 Stenciling Of Check Seal Before Delivery On Cylinders As Directed With White Paint. 71 Stenciling Of Tare Weight Of 40Mm Size In Two Places Inside Vertical Stay Of Cylinder With Black Paint 72 Stenciling Of “Switch Off Regulator After Use” As Directed With White Paint. 73 Stenciling Of Indane In English And Hindi In An Area Of 114 Mm X 268 Mm Each At Two Places On The Body Of The Cylinder As Per Direction. 74 Stenciling Of “Statutory Test Due Date And Background Painting On One Of The Vertical Staywith Appropriate Colour / Paint As Directed. 75 Cutting Of Grass. Vegitation, Tiger Grass And Unwanted Plants Etc In The Licensed Area / Buffer Zone / Unlicensed Area The Job Also Inludes The Disposal Of Cut Grass Etc At Nominated Place Inside / Outside Of The Plant Premises As Directed, . Using Trollies / Tractors As Directed. All Tools / Plants / Equipments Required For Cutting Grass Tiger Grass, Tractor Trolly For Lifting & Disposing The Same Will Be Provided By Contractor. 76 Upkeeking And Cleaning Of Drains Including Main And Branch Drains Within Plant Premises. The Job Includes Removal Of Mud / Slurge / Mick Etc. Collected In Drains And Disposing Thye Same At Nominated Place Inside / Outside Of Plant As Directed. Arrangement Of Lifting And Shifting The Slurge Etc. To Be Provided By The Contractor. 77 Spray Of Weedicides. The Job Include Spraying Of Weedicides As Supplied By The Corporation In Correct Proportion Using Manual Spray Machine As Supplied By The Corporation. The Dry Vegitations Are To Be Removed And Disposed Suitably As Directed. 78 Cleaning Of Service Water Tank On Holiday Or After Close Of Operation As And When Required The Job Includes Emptying Of Tank. Removal Of Green Moss, Scrapping Of Surface By Wire Brush. Washing By Fresh Water And Finally Filling Of Same With Fresh Water. Brushes And Brooms Will Be Provided By Contractor. 79 Cleaning Of Septic Tanks & Chambers With Suitable Device After Opening The Manhole Cover.The Job Includes The Disposal Of Waste At Nominated Place As Directed Within The Plant / Outside Plant Premises.This Also Includes Cleaning Of Drainage Pipe And Chambers As & When Required. 80 Degassing – Destacking Of Cylinders Of Any Size From Nominated Stack On The Plant Floor Shifting Of Cylinders, If Required. Opening Of Valve By Approved Tools, Filling Of Water Into The Cylinders Up To The Brim Removing The Water By Inverting The Cylinders And Shifting The Same On The Ground After Putting Corporation Supplied Bung Cap. The Item Includes All Handling Involved In The Operation. The Whole Job Will Be Considered As One Activity. All Tool Required For The Above Job Will Be Provided By Contractor. The Item Also Includes Depositing Of Valves Removed From Cylinders To Store In Proper Counting. 81 Deshaping Of Cylds By Using ( Hydraulic Press To Be Provided By Ioc ) On A Press Defacing Of All Marking On Cylds After Recording The Details In Proper Records As Directed Including Handling Of Cylds Within Plant Premises. The Requisite Press, Grinder And Electricity, Cabling And Maintenance Of The Press And Grinder Will Be Done By Corporation.This Job Includes All Type Of Lpg Cylinders ( 14.2 Kg / 19 Kg / 5.0 Kg / 47.5 Kg ) 82 Levelling Of Ground By Using Showels / Tractors / Jcbsprovided By Contractor In The Licensed / Unlicensed Area. . 83 Deshaping Of Defective Valves As Directed And Only At A Nominated Place In The Plant Premises. The Item Also Includes Shifting Of Valves After And Before Deshaping. The Job Also Includes The Packing Of Deshaped Valves In Wooden Crates Or Gunny Bags After Weightment, Painting Of Item Description And Weight Details Over The Package And Stacking Of Package At Nominated Place. Equipments For Deshaping Valves Will Be Provided By Contractor. Lot Of 100 Valves Will Be Considered As One Unit 84 Breaking Of Defective Pressure Regulators By Using Hammer As Directed. The Item Also Includes Shifting Of Prs After And Before Deshaping. The Job Also Includes The Packing Of Broken Pressure Regulators In Wooden Crates Or Gunny Bags After Weighment, Painting Of Item Description And Weight Details Over The Package And Stacking Of Package At Nominated Place. Equipments For Breaking Pressure Regulators And Paint Will Be Provided By Contractor. Lot Of 100 Prs Will Be Considered As 1 No. Unit 85 Checking Of Fire Extinguishers Of The Capacity ( 10 Kg & 75 Kg ) Mentioned Below As Per Is 3710 Once In A Quarter, Its Rectification And Maintaining A Record As Directed 86 Re-Painting Of Cylinders:The Job Include Application Of One Ccoat Of Synthetic Enamel Over One Coat Of Primer As Per The Specifications Mentioned In The Procedure Of Re-Painting Including Supply Of Paints. The Job Also Include Painting / Strencelling Of All Statutory As Well As Operating Markings And Instruction On The Cylinder Body As Mentioned In Procedure Including The Logo Of Indane. Necessary Consumables Like Screen For Printing Of Markings, Instuction Or Logo And The Required Ink Are To Be Supplied By The Contractir. The Job Also Include Shifting Of Cylinders After Due Certification To Empty Shed And Feeding Them To Conveyor For Filling. 87 For 14.2 Kg Cylinders 88 For 19 Kg Cylinders 89 Loading / Unloading Of Filled Cylinders Conveyor To Trucks & Vice Versawhere The Rates Is Being Obtained For Carrying Out Job In Case Of Exigency 90 For 14.2 Kg Cylinders 91 For 19 Kg Cylinders 92 For 5 Kg Cylinders 93 For 47.5 Kg Cylinders 94 Loading / Unloading Of Empty Cylinders Conveyor To Trucks & Vice Versawhere The Rates Is Being Obtained For Carrying Out Job In Case Of Exigency 95 For 14.2 Kg Cylinders 96 For 19 Kg Cylinders 97 For 5 Kg Cylinders 98 For 47.5 Kg Cylinders 99 Supervising And Mointoring Of Complete Work Of Loading / Unloading Of Cylinders, Haulage , Cartage , Clearing & Misc Workin Consultation With Location In Charge / Officer In Charge In Shift And Keeping Location In Charge Informed About Status 100 Sunday / Holiday Bottling As Per Job Required For Weekly Operating Dayper Carousal Per Shift. 101 Night Shift Bottling Single Carousel 102 Night Shift Bottling Doublecarousel 103 Extended Hour Bottling Whenever Required
Contract Date : 08 May, 2023   |   Contract Value : 2.27 Crore
BRR : 7251699 Tender For Katra Nagar Panchayat Water Supply Reorganisation Scheme Oht,Tube Well, Pump House,Rising Main ,Distribution Scada Automation Etc - Civil Works 2 Provide all materials, labour, T&P etc. complete and construct Pump house size (3.60x3.00x3.00)m cum Chlorinating room size (2.25 x2.25x3.0) m as per departmental type design , drawing and specif ications for civil work given in the bid document, including supply of all material, labour and T&P etc complete as per instructions of Engineer ‐in ‐ charge 3 Construction work for repairing of existing pump house cum chloronome (Repairing of damaged walls of pump house, apron & bypass chamber by patch work in 1:2:4 cement, coarse sand and ordinary sand mortar,Rubbing, washing, double coat Painting of all sides of walls of pump house and bypass chamber,Painting of windows and doors of pump house by cleaning and applying 2 coats of smoke grey enamel paint including supply of all labours, materials, T&P etc complete for zone-1 4 Construction of Pillar Platfrom and gravel feed chamberincluding supply of all labours, materials, T&P etc complete for rebore Tubewell of zone-1 (Site Clearence, excavation, concreting in foundation of pillar plat form & Gravel chamber etc. Supply of Steel, M-15 concrete & 1st class brick work in1:4 in pillar, Dismentling of girder form old T/W pillers and Fixing on Rebore T/W Pillers at the Top,Plaster,super snowcem 2 coat,1coat of white cement over pillar & platform,painting of girder etc complete work) 5 Rising Main 6 Supply of Following sizes pipes (D.I. K-9) for rising main conforming to latest relevent to I.S.83329/2000 specification with all jointing materials such as C.I. S/S or D.F. specials conforming to latest/relevant I.S. specification, suitable for D.I. pipes, as per IS-1239/2000 and IS 8329/2000 or their latest amendment including F.O.R. destination and all taxes and insurance etc. with loading, unloading and carting up to site of work.,complete. as per instructions of Engineer-in-charge. All pipes should be supplied from the firm enlisted by Material Manager UP Jal Nigam Lucknow and should be proper inspection, testing, certification & marking by M/s Crown Agents India Pvt. Ltd. New Delhi. 7 200mm dia 8 Carting laying and jointing of the following sizes of pipes into the trenches including cost of all jointing material, labour T&P and testing etc. complete of work and lowering them into the trenches and laying true to alignment and gradient and jointing etc. complete (including sectional pressure testing of pipes lines and cutting of pipes for making up the length but excluding the cost of trenches). 9 200mm dia 10 Excavation of earth in ordinary soil (loam, clay or sand) to give 1 mt. Cover from top of the pipe including lift upto 1.5 mt. and lead upto 50 mt. from centre of trenches and refilling of earth in 20 cm. layers with watering and raimming etc. complete 11 Supply and carting up to site of work of the following dia C.I./D.I. Talis/Hawale/Magwane/VAG/DOROT/Kiriloskar make butterfly/ sluice valves, Class I working pressure 10kg/cm2 confirming to IS: 780/1984 or latest amendments, F.O.R. destination, and lowering them into the already prepared trenches, fixing in position and jointing them with pipeline and testing etc. complete and also including supply of jointing materials etc. including all taxes and insurance 12 200 mm 13 Construction of masonary type Sluice valve chambers as per department type design and drawing including supply of Heavy duty M.S. Manhole Cover and all materials, labour T&P etc complete for proper completion of work as per the specification laid down in the bid document 14 Design and construct Thrust Block made in R.C.C. with cement. coarse sand & 20mm gauge stone ballast in proporation 1:1.5:3 for pipe line, including supply of MS reinforcment wrought to required shape as necessary, its bending, fixing & binding the same with 0.50mm thick binding wire in position & necessary centering & shuttering including curing and supply of all materials, labour, T&P etc. required for proper completion of the work and as per specification for RCC work given in the bid document as per instruction of Engineer-in-charge 15 Mild steel or iron work in RCC work wrought to required shape as necessary including bending for proper completion of work 16 Dismantling of Bituminous Road including sorting out and stacking of serviceable materials and disposal of unserviceable materials upto a distance of 50m required for proper completion of the work as per instruction of Engineer-in-charge. 17 Permanent re-instatement of the f ollowing ty pe of road surf ace (road shall be re-instate as specif ication found during cut) after laying of pipeline including supply of all materials, labour, T&P etc. required for completion of work. it also includes necessary excav ation required for preparation of trench for reinstatement of road, disposal of surplus unserviceable material, watering, ramming, cleaning surface for proper completion of the work as per directions of Engineer ‐in ‐charge 18 Construction of bituminious road as per dismantelled pre existingroad 19 Supply all materials labout tools and plant and Horizontal directional drilling machine laying and jointing by electric welding of following MS casing pipe by trenchless with water jetting system. 20 The successful bidder will be required to investigate the soil bearing capacity by only nationalised institute and If net safe allowable bearing capacity is found to be equivalent or more than 8 t/m2, the design of OHT will be based on 8 t/m2 capacity. However, in case the net safe allowable bearing capacity is found to be below 8 t/m2, then the design of OHT will be based on the actual bearing capacity. Design, Supply of all materials labour T&P etc. required for complete construction of R.C.C. Over Head Tank of followingcapacity and staging as specified in bid document as per direction of Engineer-in-charge. The key feature, but not limited to, pertaing to design and construction of OHT are as follows: 1. The finished floor level of OHT shall be min 0.3m above the finished ground level of the campus. 2. Soil investigation and bearing capacity.3. Structural design and drawing confirming to IS: 456, IS: 3370, IS: 1893, IS: 875 & Other relevant IS Code.4. Grade of concrete M30 for water retaining structure and concrete grade for other components shall not be less then M25.5. Saprete two column based RCC stair case of width minimum 1m.6. 1m wide R.C.C. M30 balcony, SS ladderinside the tank from top dome to bottom dome shall be made of 50x50x6 mm angle section with hand rails of 20mm SS pipes. The grade shall be SS 316.7. Railing with 20mm dia medium class G.I.pipe (in 3 rows) on both sides of stair case, supported on 50x50x6mm M.S. angle section, spaced at intervals not more than 1.5m.8. Proper ventilator at top dome in circular shape of 1.2 m dia.9. Food Grade epoxy coating of FOSROC / Ciba-Geigy or reputed brand on inside surface area of water container after testing of water tightness, two coat of apex painting over one coat of primer of approved colour after finishing of RCC surface with grinder.10. Repairs of pin holes, unevenness of all concrete surface. 11. Ultra Sonic Water level indicator fabricated with sensor connecting to automation12. Lightening conductor as per I.S.S.2309 or its latest amendments of latest electricity rules, consisting of proper elevation rod with 5 or more fork points as prescribed in ISS 2309‐1969 and ISS 3013‐1966.13. C.I. manhole of min 60x60cm size with locking arrangement.14. Supply, fixing, jointing of D.I.D/F Pipes of appropriate size with D.I.D/F specials conforming to IS 8329/2000 as vertical pipes for inlet, outlet, overflowand washoutwith Bell Mouth as per latest / relevant I.S. specifications withall jointing materials for proper completion of work.15. Construction of 120mm thick RCC floorin 1:1.5:3 with cement, coarse sand, approved stone gritand reinforcement t@8mm dia @250mm c/c both way over 100mm thick PCC 1:4:8. 16. Constructionof washout / overflow chamber and chambers for sluice / butter fly valves as per departmental type design and drawing.17. Supply of 200 mm dia PVC pipefor disposal of water from washout chamber to suitable point outside the water works compound. 18.MS steel box type enclosure ofat the entrance of the staircase having locking arrangements.19.The C.I (D/F)pipedimensions for inlet,outlet,washout,overflow will be decided as per site requirements. For bidding purpose, bearing capacity of soil shall be considered as 8t/sq.m. Working design shall be based on the SBC determined after soil investigation / 8 tonne/sqm.19Note :- The bid price of Over Head Tanks is to be submitted considering that the design of over head tank will be done by retired / working Associate proffessor of any IIT and it shall be vetted by a working professor also of IIT and The net safe allowable bearing capacity as 8 t/m2, keeping the minimum foundation depth to be 2.5 m below existing ground level at the site of work. 21 1750 KL / 22M (Zone-2) 22 RENOVATION OF EXISTINGOVER HEAD TANK of capicities 1500kl/20m staging WHICH INCLUDES FOLLOWING ITEMS:- 23 Providinganderectionofscaffoldingandshuttering materiallikechalli,gurra,nail,bans,ballia,patraetc. requiredforcompleteofworkonallsurgaceareaof OHTfromtopdometoG.L.soastogivestrongand safeplateformtoworkerstoworkon all part of OHT for repair and strengthning as per direction of engineer in-charge.Surface Preparation- The surface of structure to betreatedforstrengthningshallberoughened properly eitherby rakingjointsorby hachingthe cementconcretesurfacewithaspeciallymade hachingtoolorotherwisealternativelyto/make thesurfaceroughanddustfreebyproviding spatter key or wire brush as per direction of engineer in chargeInjectiongroutinginverticalsurface/wallplacing andfixingnozzlebydrillingmachineintankwall having minimum dia of nozzle 15mm and provide onaregularintervalnotexceeding1mincluding construction joints. Injection of pidicrete AM (Ploymer based on shrinkage high strength grout) admisxed with cement through nozle under pressure by sump @ 250gms per bag ofcement sealingthenozzleaftergroutingwithPloymer productmixedwithcement,makingtankbodyin working and seapage free condition includingsupply all materials, labour, T&P etc. for strengthning of columns, braces, stair case, balcony, vertical wall, dome etc. complete in all respect as per latest / relevant IS 3370 Part I to Part IV specificationChangeofsteelladderinsidethetank,repairof MHcoveroftopdome,changeofmosqeutojali with new one complete, repair/ change of water levei indicater, lightening conductor, vertical column pipe, valve etc. complete as per direction of engineer in charge.Supply andfixingof20mmdiaG.I.Piperailingin stair case and balcony. (Taking only 25% new and 75% old materials) as per direction of engineer in charge.Layingand fixing of 3mm thick MS wire mesh on roofofslabfornominalreinforcementincluding cost ofall labour, materials, T&P etc required for completion of workas per direction of engineer in charge.25 mm thick 1:2:4 plain cementconcrete flooring inapronwithcementcoarsesandand20mm gaugestoneballast,laidinpanelsFinishedwith 3mm floating coat of neat cement of cement including 75mm thick base concrete of 1:4:8 including supply of all material, repair of sluice valve chamber etc. as per direction of engineer in charge.Entire water proofing inside the tank water body with food grade epoxy of either FOSROC or any approved brand as per approval of Engineer in charge in order to make it complete water tight.PaintingofoutersurfaceofOHTwithwheather proofpaint(likeapexetc.)asperdirectionof engineer in-charge. 24 Construction of Local Control Station room of size 8.0m X5.0m X4.0mwith 1st class brick work(in proportion 1:3), RCC work M20 in Lintel, sunshade & Slab, Plaster, White wash & color wash, fixing 40 mm thick C.P. Teak wood all paneled door & window shutter, collapsible steel shutters with vertical channels 20x10x2mm and braced with that iron diagonal 20x5mm size with top and bottom rails of iron 40x40x6mm with 38mm dia steel pulley, rolling shutters of approved make of 80x125mm gauge, Sand filling in plinth, fixing of exhaust fan 6 nos, 150mm dia S.W. drain pipe and 100 mm dia AC pipe (As per type design & as per instruction of Engineer-in- charge) including supply of all labours, materials, T&P etc complete.(For zone-1, zone-2 & Zone-3) 25 Distribution System 26 Supply of High Density Polyethylene Pipes & electro-fusion specials (HDPE (PN-6)/PE-100), confirming to IS 4984 / 14151 / 12786 / 13488 (and other related I.S. codes) in coils / slandered lengths with necessary jointing material like electro-fusioncoupler for Joints/Junctions , flanged joint, inclusive of third party inspection charges, transit insurance, freight, transportation to store / site of work, unloading & stacking the same in covered shade duly protecting from sunrays & rains etc. complete as directed by Engineer-in-charge. All pipes should be supplied of makes mentioned in tender document and only after proper inspection, testing, certification & marking by M/s Crown Agents India Pvt. Ltd. New Delhi. 27 90mm dia H.D.P.E.6kg/cm2 28 110mm dia H.D.P.E.6kg/cm2 29 140mm dia H.D.P.E.6kg/cm2 30 160mm dia H.D.P.E.6kg/cm2 31 Supply of the following D.I. pipes (K-7) and specials conforming to I.S -8329/2000 or its latest amendment(s). Including F.O.R. destinations including cost of one Rubber Gasket per pipe length & inclusive of Third Party Inspection Charges, Packing & Forwarding Charges, Transit Insurance Charges, Road Transportation Charges etc. 32 200mm dia D .I K-7 pipe 33 250 mm dia D.I. K-7 pipe 34 300 mm dia D.I. K-7 pipe 35 350 mm dia D.I. K-7 pipe 36 Carting, lowering, laying of following dia of HDPE Pipe (PN-6)/PE-100 of following dia and requisite specials to site of work, lowering them into trenches, laying true to alignment and gradient, in proper position, cutting of pipes, making of joints including cost of jointing materials and rubber rings, labour, T&P, including hydraulic testing etc. complete as directed by Engineer-in-charge. It includes provision of making of alignment on city roads, making trial pits to investigates location of various under ground services like telephone cables, electric cable, existing pipe lines and sewer lines etc. arrangements for diversion of traffic and associated works etc. with supply of all necessary equipments, materials, labour and T&P etc. complete required for completion of work. The trenches shall be properly barricaded and fenced off wherever necessary. Red flags and caution boards during day and red lights during night shall be displayed so as to avoid any accidents. Note: Jointing between HDPE pipes and specials shall be done as per the latest IS: 7634 part II. Only Bar coded electro-fusion machine (Automatically Readable) that can read the bar code of the fittings automatically shall be used for jointing of HDPE pipe / fittings. 37 90mm dia H.D.P.E.6kg/cm2 38 110mm dia H.D.P.E.6kg/cm2 39 140mm dia H.D.P.E.6kg/cm2 40 160mm dia H.D.P.E.6kg/cm2 41 Carting, lowering, laying and jointing with SBR rubber gasket D.I. K-7 pipes of makes mentioned in tender document and of following dia & pressure including all specials to site of work, lowering them into trenches, laying true to alignment and gradient, in proper position, cutting of pipes, making of joints including cost of jointing materials and rubber rings, labour, T&P, including hydraulic testing etc. complete as directed by Engineer-in-charge. It includes provision of making of alignment on city roads, making trial pits to investigates location of various under ground services like telephone cables, electric cable, existing pipe lines and sewer lines etc. arrangements for diversion of traffic and associated works etc. with supply of all necessary equipments, materials, labour and T&P etc. complete required for completion of work. The trenches shall be properly barricaded and fenced off wherever necessary. Red flags and caution boards during day and red lights during night shall be displayed so as to avoid any accidents. Note: Only SBR rubber gaskets to be used as per IS-5382 and IS- 12820. 42 200mm dia D .I K-7 pipe 43 250 mm dia D.I. K-7 pipe 44 300 mm dia D.I. K-7 pipe 45 350 mm dia D.I. K-7 pipe 46 Excavation of earth in ordinary soil (loam, clay or sand) for pipe linemain trenches including lift upto 1.50 m and lead upto 50 m and refilling watering, ramming of the excavated earth into the trench and also disposal of surplus earth upto 50m from the center of the trenches including supply of all material labour, T&P etc complete as per instructions of Engineer ‐in ‐charge. Guide lines on envirmental of construction and demolition (C&D) wastes and GRAP circulated by Central Pollution Control Board in Year 2017 and its latest amendments shall be adhered to during excavation of trench for laying of pipe line.Surplus material after backfilling of trench shall immediately be removed from site and temporary restoration shall be done immediately to make the road motorable. 47 Supply and carting up to site of work of the following dia C.I./D.I. Talis/Hawale/Magwane/VAG/DOROT/Kiriloskar make butterfly/sluice valves, Class I working pressure 10kg/cm2 confirming to IS: 780/1984 or latest amendments, F.O.R. destination, and lowering them into the already prepared trenches, fixing in position and jointing them with pipeline and testing etc. complete and also including supply of jointing materials etc. including all taxes and insurance 48 Sluice Valve 80 mm dia 49 Sluice Valve 125 mm dia 50 Sluice Valve 150 mm dia 51 Sluice Valve 350mm dia 52 Scour Valve 80 mm dia 53 Supply of underground sluice valve type fire hydrant consisting of 80mm dia sluice valve, 100mm dia tail pieces, 100mm dia duck foot bend and 80mm dia standard makes iron coupling with cap and etc. complete conforming to latest/relevent I.S. specifications including all taxes and insurance up to site of work and lowering them into the trenches, fixing in position and jointing them with pipeline and testing etc. complete (including supply of jointing materials etc complete.) as per instructions of Engineer-in-charge. 54 Supply of screwed down type 80mm dia air valve with gun metal seat conforming to latest/relevent I.S. specifications including all taxes and insurance, carting up to site of work and lowering them into the trenches, fixing in position and jointing them with pipelines and testing etc. complete (including supply of jointing materials etc complete) as per instructions of Engineer-in-charge. 55 Construction of following type chambers as per department type design and drawing including supply of Heavy duty M.S. Manhole Cover and all materials, labour T&P etc complete for proper completion of work as per the specification laid down in the bid document 56 Sluice Valve/Scour Valve Chamber Masonary Type For Distribution Main 57 Sluice Valve/Scour Valve Chamber Surface Box Type For Distribution Main 58 Fire Hydrant Chamber For Distribution Main 59 Air Valve Chamber For Distribution Main 60 Dismantling of following type of surface including sorting out and stacking of serviceable materials and disposal of unserviceable materials upto a distance of 50m required for proper completion of the work as per instruction of Engineer-in-charge. 61 B.O.E. Surface 62 Tiles Road 63 Bituminous Road 64 C.C. Road 65 Permanent re-instatement of the f ollowing ty pe of road surf ace ( road shall be re-instate as specif ication found during cut ) after laying of pipeline including supply of all materials, labour, T&P etc. required for completion of work. it also includes necessary excav ation required f or preparation of trench for reinstatement of road, disposal of surplus unserviceable material, watering, ramming, cleaning surface for proper completion of the work as per directions of Engineer ‐in ‐charge 66 Laying of B.O.E. Surface (with new bricks upto 40% quantity) as per according to PWD specification of the respective roads and proper compaction. 67 construction ofC.C interlocking road as per dismantelled pre existing road 68 construction of bituminious road as per dismantelled pre existingroad 69 Laying of C.C. Road with concrete of 1:2:4 (1 Cement: 2 Coarse Sand: 20 mm Stone Aggregate) 10 cm thickness may be taken according to PWD specification of the respective roads with 7.5 cm thickness base concrete 1:4:8 (1 Cement: 4 Coarse Sand: 40 mm stone ballst) and proper compaction 70 Provision of crossing of Nalas & culvert (Square drain) complete i.e. total material (including supply of all materials including FOR Destinaion inclusive of all taxes and duties third party inspection charge, transit insurance, freight, loading, unloading and stacking in departmental store etc. complete) & labour cost per metre as per type design & as per instruction of Engineer-in- charge. 71 Supply all materials labout tools and plant and Horizontal directional drilling machine laying and jointing by electric welding of following MS casing pipe by trenchless with water jetting system 72 300mm dia under Zone-1 73 200mm dia under Zone-2 74 Provision of crossing of Nalas & culvert (above 3.5) complete i.e. total material (including supply of all materials including FOR Destinaion inclusive of all taxes and duties third party inspection charge, transit insurance, freight, loading, unloading and stacking in departmental store etc. complete) & labour cost per metre as per type design & as per instruction of Engineer-in- charge. 75 Provision of crossing of Road (3.5 m) complete i.e. total material (including supply of all materials including FOR Destinaion inclusive of all taxes and duties third party inspection charge, transit insurance, freight, loading, unloading and stacking in departmental store etc. complete) & labour cost per metre as per type design & as per instruction of Engineer-in- charge. 76 Shifting of Telephone line, Protection to electric cables, gas pipeline, optical fiber cable, existing water supply mains etc falling in the alignment of water line during excavation/laying water line and the restoring utilities/services to its original condition etc. 77 Supply of all material like HDPE/GI pipe (Use of combination ofboth pipes as per drawing provided by Engineer-in-charge)15 mm. dia, specials & fittings such as brass ferrule, clamp, service saddle,brass bib cock,20mm FTC,MTC etc. complete as per relevant I.S. specifications for making house connection including excavation, cutting of HDPE/GI pipe etc. complete in all respect. 78 90 to 110 mm Pipe line 79 125 to 160 mm Pipe line 80 160 to 200mm Pipe line 81 200 to 250 mm Pipe line 82 Supply of all material like HDPE/GI pipe (Use of combination ofboth pipes as per drawing provided by Engineer-in-charge)15 mm. dia, specials & fittings such as brass ferrule, clamp, service saddle,brass bib cock,20mm FTC,MTC etc. complete as per relevant I.S. specifications for Shifting of existing house connection to new pipe line including excavation, cutting of HDPE/GI pipe etc. complete in all respect. 83 90 to 110 mm Pipe line 84 125 to 160 mm Pipe line 85 160 to 200 mm Pipe line 86 Construction of Boundary Wall including excavation, PCC, DPC, 1st class brick work plaster, putty and white washing in three coat etc. complete work as per type design & as per instruction of Engineer-in- charge including supply of labours, materials T&P etc complete. 87 Construction of Damaged boundary wall including supply all materials, labour, T&P etc. complete &other appurtenant work as per estimated. 88 Painting work with weather coat approved quality of paints on wall both side. 89 Painting or varnishing of iron or wood with one coat of priming and two coats of approved paint & varnish including supply of all materials, labor, T & P etc; required for proper completion of the work 90 12mm thick plaster with cement and coarse sand mortar in 1:4 over brick work including supply of all materials, labour T&P etc. complete. 91 Construction of Interlocking type approach road including supply of all materials, labour, tools and plants etc. complete 92 Supply and fixing of 3.6m X 1.50m MS gate and 1.2 m X 1.50m MS wicket gate including construction of RCC pillars of Size 1.35m X 0.23m X 0.23m with ornamental brick work 115mm Thick around RCC with constuct gate pillars 1.2m wicket gate, as per departmental type design and drawing and as per specifications laid down in the bid document, including supply of all material, labour, varnishing,painting ,T&P etc. required for proper completion of work, as per instructions of engineer-in-charge. 93 Supply and fixing of 1.2 m X 1.50m MS wicket gate including construction of RCC pillars of Size 1.35m X 0.23m X 0.23m with ornamental brick work 115mm Thick around RCC with constuct gate pillars 1.2m wicket gate, as per departmental type design and drawing and as per specifications laid down in the bid document, including supply of all material, labour, varnishing,painting ,T&P etc. required for proper completion of work, as per instructions of engineer-in-charge. 94 Demolition of existing unserviceable 200 KL/18m Stagging over head tank and disposal of dismentalled material at a location as desired by nagar panchayat Katra including all necessary saftey arrangemetfor demolition works to avoid any accidents at site and alsore-construction of existing RCC Shed parkng if dismantelled at a location as desired by Nagar Panchat authorities. 95 Laying of Tiles Roadas per according to PWD specification of the respective roads and proper compaction. 96 Construction of Staff Quarter including excavation, PCC, DPC, 1st class brick work plaster, apron verified tile flooring over 40mm thick M15 concrete and 75 mm thick PCC, putty and Color washing in two coat over one primer coat, Painting and varnishing in two coat of new iron work, 250mm dia S.C. drain, electrification work, Sanitation work and water supply etc. complete work as per type design & as per instruction of Engineer-in- charge including supply of all materials, laboursT&P etc complete 97 Supply of all materials labour and construction of Ground Water Recharge as per department design & drawing required for proper completion of work, asper instructions of Engineer-in-charge. 98 E&M WORKS 99 Rebore Tubewell Zone-1 100 Transportation of T/W Construction T&P Units 101 Transportation, Erection, Dismantling of Rig Machine and its T&P 102 Transportation, Erection, Dismantling of Compressor 250/350 PSI 103 Transportation, Erection, Dismantling of 2 Cusec/ 3 Cusec O.P. Unit and Yield test 104 Supply of Tubewell AssemblyM.S.Tubewell assembly with all required parts like plain pipe, Slotted pipe as required upto 50% of plain pipes rings, well cap bail plug, clamp, reducer, central guide, suport structure etc. as required & as per typed design complete in all respect. Note- Axial Length of Reducer without Ring shall be measured with casing pipe 105 300 mm dia M.S. Pipe 106 200 mm dia M.S. Plain/slotted 107 PEA-GRAVEL As per IS:4097 108 1.65 mm to 4.50 mm size Pea gravel of Lalkuwan quarry duly screened, washed and properly stacked at sitefor Tubewell 109 Drilling of bore by rig machine As Per IS:2800 Part I & II: 110 Drilling of bore by 600 mm dia bit GL to 50 mt. BGL. 111 Drilling of bore by 500 mm dia bit from 50 mt GL to 100 mt. BGL. 112 Drilling of bore by 500 mm dia bit 100 m BGL to 165 m. BGL. 113 Lowering of tube well assembly With M.S. rings, Bail Plug, Reducer Including welding: 114 Lowering of 300 mm dia M.S. Housing pipe from GL to 42 m.BGL 115 Lowering of 200 mm dia M.S. Plain/slotted pipe 42 m. BGL to 100 m. BGL 116 Lowering of 200 mm dia M.S. Plain/slotted pipe 100 m. BGL to 150 m. BGL 117 Development of tube well by 250 PSI air compressor and 3 cusec O.P. Unit to yield sand free discharge. 118 Development and testing of tube well by Air Compressor. 119 Development and testing of tube Well O.P.Unit to yield sand free Discharge. 120 Chemical and Bacteriological test Analysis of water sample 121 Logging of borehole by departmental/approved electric logger 122 New Tubewell Zone 1 & 2 123 Transportation of T/W Construction T&P Units 124 Transportation, Erection, Dismantling of Rig Machine and its T&P 125 Transportation, Erection, Dismantling of Compressor 250/350 PSI 126 Transportation, Erection, Dismantling of 2 Cusec/ 3 Cusec O.P. Unit and Yield test 127 Supply of Tubewell AssemblyM.S.Tubewell assembly with all required parts like plain pipe, Slotted pipe (as required upto 50% of plain pipes) rings, well cap bail plug, clamp reducer, central guide, suport structure etc. as required & as per typed design complete in all respect. (Note- Axial Length of Reducer without Ring shall be measured with casing pipe) 128 300 mm dia M.S. Pipe 129 200 mm dia M.S. Plain/slotted 130 PEA-GRAVEL (As per IS:4097) 131 1.65 mm to 4.50 mm size Pea gravel of Lalkuwan quarry duly screened, washed and properly stacked at sitefor Tubewell 132 Drilling of bore by rig machine As Per IS:2800(Part I & II): 133 Drilling of bore by 600 mm dia bit GL to 60 mt. BGL. 134 Drilling of bore by 500 mm dia bit from 60 mt GL to 100 mt. BGL. 135 Drilling of bore by 500 mm dia bit 100 m BGL to 165 m. BGL. 136 Lowering of tube well assembly With M.S. rings, Bail Plug, Reducer Including welding: 137 Lowering of 300 mm dia M.S. Housing pipe from GL to 50 m.BGL 138 Lowering of 200 mm dia M.S. Plain/slotted pipe 50 m. BGL to 100 m. BGL 139 Lowering of 200 mm dia M.S. Plain/slotted pipe 100 m. BGL to 150 m. BGL 140 Development of tube well by 250 PSI air compressor and 3 cusec O.P. Unit to yield sand free discharge. 141 Development and testing of tube well by Air Compressor. 142 Development and testing of tube Well O.P.Unit to yield sand free Discharge. 143 Chemical and Bacteriological test (Analysis of water sample) 144 Logging of borehole by departmental/approved electric logger 145 Details of New Pumping Plant & Servo Voltage Stabilizer for Rebore Tubewell 146 SITC of Submersible pumpset having capacity 1500 LPM,50 mtr Head, 30 HP or as per requirement of site with 24 mtr Column Pipe Assembly, NRV, CIDF Bend 90°, CF A/F Tee, D/F Pipe1.5 m long 2 No.s and 1 m long 1 No., Earthing, Painting, Toolset, Power wiring of pump house internal & external, Chainpulley block and all Pumping Plant accessories with nut bolts and rubber packing etc. 147 SITC of automatic servo voltage Stabilizer-50 KVA Input Voltage 230V±500Vto Output Voltage415V± 1% As per IS 9815-1994 148 SITC of Soft Starter with RS485 Port-400V Class 22.5 kW, Rating. 149 Additional Coloumn Pipe 3 mtr long 150 Internal Electrification of Pump House 151 Details of New Pumping Plant & Servo Voltage Stabilizer for New Tubewell 152 SITC of Submersible pumpset having capacity 1500 LPM,50-55 mtr Head, 30 HP or as per requirement of sitewith 24 mtr Column Pipe Assembly, NRV, CIDF Bend 90°, CF A/F Tee, D/F Pipe 1.5 m long 2 No.s and 1 m long 1 No., Earthing, Painting, Toolset, Power wiring of pump house internal & external, Chainpulley block and all Pumping Plant accessories with nut bolts and rubber packing etc. 153 SITC of automatic servo voltage Stabilizer-50 KVA Input Voltage 230V±500V to Output Voltage 415V± 1% As per IS 9815-1994 154 SITC of Soft Starter with RS485 Port-400V Class 22.5 kW, Rating. 155 Additional Coloumn Pipe 3 mtr long 156 Internal Electrification of Pump House 157 Supply & Laying of Submersible Cable from Rebore T/w to OldPump House 158 Supply and Laying of Flat submersible Cable of 10 sq. mm from Rebore T/w to existing pump house with material and labour including PVC pipe . 159 Supply & Laying of LT Cable from Transformer to Meter and From Meter to Main Switch Incomer Panel for all Tubewell 160 Supply and Laying of LT Power Cable of 50 sq. mm. 3.5 Core for connetion from transformer to Meter and meter to main switch incomer panel/ kitkat switches withrequired Material and Labour for 6 Tubewell 161 SITC Of SCADA /AUTOMATION WORK OF PUMPING PLANT for all Zones 162 CE/UL certifeid Intelligent Smart Energy Meter 163 Moter Operated Actuater with inbuilt starter for Existing Valves 150 mm size having positioning card 164 Main Switch Incomer Panel 165 Actuator Panel 166 CE/UL Certifeid Electromagnetic Flow Meter 150 mm size with local display 167 Auto Phase reversal unit with inbuilt delay and enclosure control panel etc. 168 CE/UL Certifeid Hydrostatic type sub soil water level transmitter for tubewell 169 CE/UL certifeid 3 Phase Surge Protecter for complete control panel/ for all instruments 170 CE/UL certifeid Pressure Transmiter with local display 171 CE/UL Certifeid 7 hmi touch screen suitable to communication with PLC/RTU for display & control of process parameters 172 Complete cabling including power cables of all equipment. 173 Control panel with IP54 protection ,industrial grade for all equipments.separate for control (24V) and power equipment 174 Automatic Chlorination System compatible to SCADA system with scada compatiability and having level sensor in Dozing tank 175 SITC of Following Equipments For OHT Automation 176 CE/UL certifeid Radar Type level transmitter for OHT of zone -1,2&3. 177 Actuator (having inbuilt starter) with valve of 350 mm dia size forOHT ofZone -1 having positioning card 178 CE/UL certifeid Electromagnetic Flowmeters for OHT.size 350 mmfor Zone -1 with local display 179 Actuator (having inbuilt starter) with valve of 350 mm dia size forOHT of Zone -2 having positioning card 180 CE/UL certifeid Electromagnetic Flowmeters for OHT.size 350 mmfor Zone -2 with local display 181 Installation, commissioning & testing trial of Sluice Valve in distribution line of OLD existing OHT incluiding cutting and dismenting of old Sluice Valve and Arrangement for draing out the water of OHT linefor ZONE-1 182 Actuator Panel for OHT Actuated Valve with UPS for 8 hr backup 183 SITC of SCADA /AUTOMATION WORK OF PUMPING PLANT 184 CE & UL Certifeid PLC/RTU in IP 54 enclousure suitable to communicate with GSM based modem unit with CPU and power supply with analog and digital parameter and features as specifeid for tubewell to store and transmit data on GSM backbone RTU/PLC designed with logic to transfer data at multiple stations specifeid.Must be provided with battery backup of complete panel for minimum 5 Hours. with 1 kva UPS 185 GSM/GPRS based wireless communication with 4G modem for RTU/PLC capable to transfer & gather data from remote site to control station all accessoreis included with signal enhancer antenna made for pumping plant internet charges as specifeid 186 SITC of Following Equipments of LOCAL CONTROL STATION 187 CE/UL & BIS Certified industrial grade LED MONITOR with lates configuration as per specification. 188 Desktop/PC with i5/i7 processor for as per spec mentioned in tachnical bid documents. 189 CE/UL Certified 3 KVA UPS with batteries as perspec mentioned in tachnical bid documents. 190 Full development version of required TAGS SCADA Software with coustomization of software for LCS as per spec mentioned in tachnical bid documents. Of reputed make only 191 CE/UL certified local conrol room PLC with redundant CPU& power supply at LCS in IP 54 enclouser as per spec mentioned in tachnical bid documents. 192 GSM based wireless/Broadband/Equivalent communication system for PLC capable to transfer & receive data & gather data form remote sites to control station,All accessories include signal enhancer antenna along with running expences till DLP. 193 CE/UL certified Firewall for network protection. 194 Local video screen display size 56 195 Surge protector for Ethernet communication protection. 196 Industrial grade Ethernet Switch. 197 Canon/hp Laser printer1018 or equivalent 198 Installation,Commissioning ,testing including required furniture,internal wiring,PVC panelling of walls/false ceiling work etc. 199 Split AC suitable for the control room 1.5 tonnes 200 Security Survelliance IP Camera with required hard drive to store data of atleast 15 Days 201 Rehabiliation of JE Room in Divisional office (E&M) including repairing of flooring, repairing of roof to prevent leakage, internal electrification with required electrical equipment and replacement of inverter batteries with all labour material T&P etc complete. As per the direction of Engineer incharge 202 Charges for 3 MonthTrial and Run Period for all above istallation on all equipment of Tubewell, OHT, SCADA, LCS. 203 Charges for 3 month Trial and Run Period for expenditure of Sodium hypochloride Solution. 204 Skilled computer operater to operating pumping plant in LCS Room for 8 hours shift per day 3 shift. 205 Chowkidar for watch&ward for LCS Room 8 hours shift per day 3 shift .
Contract Date : 17 Apr, 2025   |   Contract Value : 20.44 Crore
BRR : 1825522 Annual Maintenance Contract ( For 33Kv / 6.6 Kv Ht Switchyard, Substation Equipment ) ( Arc Items ) For Electrical Works And General Cp / Psp / Mov Related Works At Erpl Patna Pump Station-2 Complete Quarterly Manintenance Of 33 Kv / 6.6 Kv Ht Switchyard Equipments, Substation Equipments, Pump Station Equipments / Area, Under Erpl Patna Station Jurisdiction As Defined In Scope Of Work & Technical Specifications. List Of Equipments Are As Follows:- ( A ) Transformer & Ngr ( B ) Circuit Breaker ( Vcb ) ( C ) Air Circuit Breaker ( Acb ) ( D ) Current Transformer ( E ) Potential Transformer ( F ) Isolatorswitch ( G ) Earth Switch ( H ) Lightning Arrestor ( I ) Post Insulator ( J ) Protection System Of Entire Electrical System ( K ) Capacitor Bank ( L ) Mov Actuatorrates Will Be Inclusive Of Boarding, Lodging, Local Conveyance, Mobilization & Demobilization, Manpower, Equipment, Tools & Tackles And All Other Incidental Cost. 3 Complete Half Yearly Manintenance Of 33 Kv / 6.6 Kv Ht Switchyard Equipments, Substation Equipments, Pump Station Equipments / Area, Under Erpl Patna Station Jurisdiction As Defined In Scope Of Work & Technical Specifications. List Of Equipments Are As Follows:- ( A ) Transformer & Ngr ( B ) Circuit Breaker ( Vcb ) ( C ) Air Circuit Breaker ( Acb ) ( D ) Current Transformer ( E ) Potential Transformer ( F ) Isolatorswitch ( G ) Earth Switch ( H ) Lightning Arrestor ( I ) Post Insulator ( J ) Protection System Of Entire Electrical System ( K ) Capacitor Bank ( L ) Mov Actuatorrates Will Be Inclusive Of Boarding, Lodging, Local Conveyance, Mobilization & Demobilization, Manpower, Equipment, Tools & Tackles And All Other Incidental Cost. 4 Complete Yearlymanintenance Of 33 Kv / 6.6 Kv Ht Switchyard Equipments, Substation Equipments, Pump Station Equipments / Area, Under Erpl Patna Station Jurisdiction As Defined In Scope Of Work & Technical Specifications. List Of Equipments Are As Follows:- ( A ) Transformer & Ngr ( B ) Circuit Breaker ( Vcb ) ( C ) Air Circuit Breaker ( Acb ) ( D ) Current Transformer ( E ) Potential Transformer ( F ) Isolatorswitch ( G ) Earth Switch ( H ) Lightning Arrestor ( I ) Post Insulator ( J ) Protection System Of Entire Electrical System ( K ) Capacitor Bank ( L ) Mov Actuatorrates Will Be Inclusive Of Boarding, Lodging, Local Conveyance, Mobilization & Demobilization, Manpower, Equipment, Tools & Tackles And All Other Incidental Cost. 5 Relay Coordination, Testing And Calibration ( Relay Calibrator Being Used For The Work Should Be Calibrated By An Nabl Authorized Agency ) Of All Relays As Defined In Scope Of Work & Technical Specifications To Be Done Once In A Year. ( 1 Unit Of This Item Constitutes 138 Relays Listed In Scope Of Work & Technical Specifications ) . These 138 Relays Constitute Of Numerical Relays And Electromagnetic Relays ( Mostly Contact Multiplier Like K86, Tc Supn, Transformer Aux, Etc ) Rates Will Be Inclusive Of Boarding, Lodging, Local Conveyance, Mobilization & Demobilization, Manpower, Equipment, Tools & Tackles And All Other Incidental Cost. Work Schedule Will Be As Per Instruction Of Site Engineer / Eic. 6 Testing And Calibration ( Meter Calibrator Being Used For The Work Should Be Calibrated By An Nabl Authorized Agency ) Of All Meters As Defined In Scope Of Work & Technical Specifications To Be Done Once In A Year. ( 1 Unit Of This Item Constitutes 165 Meters Listed In Scope Of Work & Technical Specifications ) .Rates Will Be Inclusive Of Boarding, Lodging, Local Conveyance, Mobilization & Demobilization, Manpower, Equipment, Tools & Tackles And All Other Incidental Cost. Work Schedule Will Be As Per Instruction Of Site Engineer / Eic. 7 Testing And Calibration ( Through Nabl Certified Laboratory ) Of All Electrical Measuring Instruments As Defined In Scope Of Work & Technical Specifications To Be Done Once In A Year. ( 1 Unit Of This Item Constitutes 10 Measuring Instruments Listed In Scope Of Work & Technical Specifications ) . Rates Will Be Inclusive Of Boarding, Lodging, Local Conveyance, Mobilization & Demobilization, Manpower, Equipment, Tools & Tackles And All Other Incidental Cost. Work Schedule Will Be As Per Instruction Of Site Engineer / Eic. 8 Routine Breakdown Visit As Defined In Scope Of Work & Technical Specifications.Routine Breakdown Maintenance Means Identifying Reason For Malfunction / Not Working / Not Running Of Electrical Equipment On S Witching ( As Per Instruction Of Eic ) , By A Team Of ( 1+1 ) Engineer + Assistants, In Time Schedule Given By Engineer In Charge ( Quantity Of Routine Breakdown Maintenance Will Be Number Of Days As Per Schedule By Eic, Considering 8 Working Hours Per Day ) Rates Will Be Inclusive Of Boarding, Lodging, Local Conveyance, Mobilization & Demobilization, Manpower, Equipment, Tools & Tackles And All Other Incidental Cost. 9 Minor Breakdown Manintenance As Defined In Scope Of Work & Technical Specifications. Minor Faults In The Installed Items Are Where No Major Breakdown Has Occurred. In Minor Breakdown Maintenance, System Is To Be Stabilized In Maximum Duration Of 12 Working Hours From The Time Of Instruction By Se / Eic And Shall Mean A Team Of ( 1+4 ) Engineer + Assistants. Rates Will Be Inclusive Of Boarding, Lodging, Local Conveyance, Mobilization & Demobilization, Manpower, Equipment, Tools & Tackles And All Other Incidental Cost. Work Schedule Will Be As Per Instruction Of Site Engineer / Eic. 10 Major Breakdown Manintenance As Defined In Scope Of Work & Technical Specifications.Work Shall Be Termed As Major Breakdown, If Items Such As Crane, Specialized Lifting Equipment, Highly Skilled Man-Power Deputation, Major Spares Replacements, Etc. Are Required. [ Spare Shall Be Given By Iocl Or Extra Payment Shall Be Made For This ] , In This, System Is To Be Stabilized In Time Schedule Given By Engineer In Charge. Rates Will Be Inclusive Of Boarding, Lodging, Local Conveyance, Mobilization & Demobilization, Manpower, Equipment, Tools & Tackles And All Other Incidental Cost. 11 Attending Power Failure To System In Cp / Rcp / Mov Station As Defined In Scope Of Work & Technical Specifications. Stations Have Lt Power Supply Controlled By Mcb / Contactor. Restoration After Power Failure / Supply Interruption To The Input Terminal Of Main System Installed, Is Only In Scope Of This Work. Power Failure Or Interruption Issue Is To Be Attended By ( Restoring Supply ) / ( Bypassing Inverter ) Within 6 Hours ( From The Time Of Instruction By Se / Eic ) . In Case Of Fault In Inverter / Battery / Battery Charger, It Must Be Repaired And Reinstalled In Station Within 72 Hours ( From The Time Of Instruction By Se / Eic ) [ Cost Of Any Part Replacement Will Be Paid Extra ] . Contractor Has To Arrange For Repairing Of Inverter / Battery / Battery Chargerrates Will Be Inclusive Of Boarding, Lodging, Local Conveyance, Mobilization & Demobilization, Manpower, Equipment, Tools & Tackles And All Other Incidental Cost. Work Schedule Will Be As Per Instruction Of Site Engineer / Eic. 12 Service Assistance For Psp Checking, Inspecting Proper Functioning Of Lights And Exhaust Fans, Refilling Distilled Water In Batteries, Cleaning Of Solar Panels, Checking Fence Energizer, Checking Earth Pit & Anode Bed Condition, Checking System Functionality, Upkeeping Of Jbs, Cleaning Trenches And Earth Pits, Greasing And Painting Of Rusted Parts In Cp Stations Complete In All Respectunder The Supervision Of Iocl Personnel As Per Direction Of E-I-C. Contractor Has To Arrange Distilled Water & Lodgingarrangement For The Worker On His Own Expense. One Personnel Of Contractor May Commute Withiocl Personnel In Office Vehicle During Cp / Rcp / Sv Station Visits, But He Has To Reach To Vehicle Start Point And Return From Vehicle End Point At His Own Expense. All Required Material, Tools & Tackles, Equipment Is To Be Arranged By Contractor.Rates Will Be Inclusive Of Boarding, Lodging, Local Conveyance, Mobilization & Demobilization, Manpower, Equipment, Tools & Tackles And All Other Incidental Cost. Work Schedule Will Be As Per Instruction Of Site Engineer / Eic. 1 Unit Is For 1 Cp Station. [ Maintenance Of 2 Cp Stations Shall Require 1 Semiskilled Manday ] 13 Service Assistance For Psp Survey ( During Day Period ) Including Greasing Of Psp Connection, Carrying Measuring Instruments To Tlp Site, Bolting Of Tlp Post Door, Cleaning Of Tlps And Clearing Nearby Vegetations Complete In All Respect Including All Tools & Tackles And Consumables Under The Supervision Of Iocl Personnel As Per Direction Of E-I-C. Contractor Has To Arrange Lodging Of His Worker On His Own Expense. One Personnel Of Contractor May Commute Withiocl Personnel In Office Vehicle During Psp In Row, But He Has To Reach To Vehicle Start Point And Return From Vehicle End Point At His Own Expense. All Required Material, Tools & Tackles, Equipment Is To Be Arranged By Contractor. For Psp Measurement, Iocl Meters Will Be Used. Rates Will Be Inclusive Of Boarding, Lodging, Local Conveyance, Mobilization & Demobilization, Manpower, Equipment, Tools & Tackles And All Other Incidental Cost. Work Schedule Will Be As Per Instruction Of Site Engineer / Eic.1 Unit Is For Psp Survey Of All Pipelines In 1 Km Of Row. [ Psp Survey Of All Pipelines In 10Km Shall Require 1 Semiskilled Manday ] 14 Service Assistance For Mov / Pcv Actuator Maintenance. Actuators Are Of Make Biffi, Rotork And Auma. Assistance In Mov Actuator Maintenance, Complete In All Respect Under The Supervision Of Iocl Personnel As Per Direction Of Eic. Rates Will Be Inclusive Of Boarding, Lodging, Local Conveyance, Mobilization & Demobilization, Manpower, Equipment, Tools & Tackles And All Other Incidental Cost. Work Schedule Will Be As Per Instruction Of Site Engineer / Eic.1 Unit Is For 1 Mov Actuator Maintenance. Maintenance Of 10 Mov Actuator Shall Require 1 Semiskilled Manday ] 15 Filtration Of Transformer Oil By Stream Line Filter Machine Provided By The Contractor For Improving The Insulation Strength Of Oil To The Required Strength As Per Specification Given Below ( Excluding The Supply Of Oil ) . A ) Filtration Of Transformer Oil Till Bdv As Per Instruction Of Eic Is Attained. B ) Topping Up Of Oil. C ) Releasing All The Air From Air Release Plug & Bucholz Relay. D ) To And Fro Transportation Of Filter Machine And Equipments. E ) Conducting Transformer Oil Tests As Mentioned In Scope Of Work. 16 Electrical Composite Items 17 Caution Board 18 Supply And Install Caution Boards For Switchyard Voltage System As Per Iss-2551-1963 Complete In English / Hindi / Local Language. 19 Earthing Plate 20 Supply & Installation Of G.I. Earthing Plate Outside The Buildings. The Item Also Includes Grouting Of The Plate. The Item Should Be Complete In All Respect Including All Materials, Tools, Tackels Etc. And As Per Direction Of Eic / Site Engineer. 21 Earth Strip / Wire / Rope / Cable - Supply, Installing And Testing Of Earthing Strip / Wire / Rope / Cable For Completely Making The Earthing Grid System By Supplying, Laying The Gi / Cu Strip And Making All The Necessary Welding Joints, Connecting To The Earthing Electrodes And Existing Earthing Grid Etc., Complete As Per Directions Of The Site Engineer / Engineer-In-Charge, Including The Cost Of All Labour, Tools, Materials, Etc. Complete In All Respect: 22 50 Mm X 6 Mm G.I. Earthing Strip 23 40 Mm X 5 Mm G.I. Earthing Strip 24 25Mm X 4 Mm Copper Flat 25 25Mm X 3 Mm Copper Flat 26 Gi Wire ( 8 Swg ) 27 Gi Wire / Rope 35 Sq. Mm 28 Gi Wire / Rope 10 Mm Diameter 29 Copper Cable As Per Specifications - 100 Sq.Mm 30 Copper Cable As Per Specifications - 10 Sq.Mm 31 Earthing Grid ( Gi Strip ) : Supply, Installation And Testing Of 75 Mm X 10 Mm Gi Earthing Strip For Completely Making The Earthing Grid System By Supplying, Laying The G.I. Strip And Making All The Necessary Welding Joints, Connecting To The Earthing Electrodes And Existing Earthing Grid Etc. Complete In All Respects Including Consumables, Tools / Equipments And Labour As Per Directions Of Engineer-In-Charge / Site Engineer. 32 Earthing Electrode 33 Supplying, Installation, Testing Of Gi Earthing Electrode Including The Supply And Installation Of The G.I. Cover, Charcoal Etc. Complete In All Respects Including Consummables, Tools / Equipments And Labour As Per Directions Of Engineer-In-Charge / Site Engineer. 34 Pvc Conduit Pipes - Supply, Installation, Fixing In Position, Pvc Conduit Pipes, Of Isi Marked , In Concrete, Brick Work Etc. During Or After Construction By Making Grooves In The Wall, Ceiling Etc. Cutting Threads And Jointing The Pipes With Pvc Couplers, Providing Necessary Tees, Bends, Junction Boxes Etc. With 12 Swg Gi Wire Inside Conduit Without Joint For Concealed Wiring, Including Making Good The Concrete, Brick Work, Surfaces Etc. Complete As Per Direction Of Site Engineer / Engineer-In-Charge Including Cost Of All Labour, Materials Etc.: 35 19 Mm 36 25 Mm 37 32 Mm 38 Supply & Fixing Of Pvc Conduit On Surface: Supply And Fixing Of Following Size Of Pvc Conduit Along With The Accessories In Surface Including Cutting The Wal Land Making Good The Same In Case Of Reessed, Conduit As Required: Note: Only Isi Marked Conduits Shall Be Used. 39 20 Mm 40 25 Mm 41 32 Mm 42 40 Mm 43 50 Mm 44 Supply & Fixing Of Pvc Casing / Caping: Providing And Fixing Following Size Of Pvc Casing And Capingon Surface As Required. Note: Only Isi Marked Caping And Casing Shall Be Used. 45 15 Mm X 10 Mm 46 20 Mm X 10 Mm 47 25 Mm X 10 Mm 48 30 Mm X 10 Mm 49 40 Mm X 20 Mm 50 50 Mm X 20 Mm 51 Supply & Fixing Chequered Plates 52 Supply, Installation And Fixing Of Ms Chequered Plates Of 5Mm Thickness. Job Includes Cutting To Size, Supply Of Hinges / Hooks For Lifting, Tag Welding With Support Wherever Required, Painting Including Supply Of Paint, Supply Of All Material And Labor Complete In All Respect 53 Hard Stone Laying ( Sw Yard ) : Providing And Spreading 40Mm Size Approved Hard Stone Chips Around Transformer Yard In One Layer Of 100Mm Thick. Job Includes Dressing Of Soil Surface And Laying The Aggregate In Uniform Laying And Density As Per Direction Of Site Engineer Aggregate Shall Be Measured In Boxes Of Size 1.1 / 2M X 1.1 / 2M X 1.1 / 2M Which Shall Be Taken As 1M3. The Boxes Will Be Supplied By Contractor Free Of Charge For Measuring Purpose. 54 Supply Of 40Mm Size Stone Chips Per M3 55 Spreading The Stone Chips Per M3 56 Putty Application 57 Application Of Pvc Putty / M-Seal Putty On Lighting Fixtures / Jn. Boxes / Glands / Switch Boards Etc. To Avoid Entering Water / Insects / Any Other Type Of Things As Per Direction Of The Engineer-In-Charge. Note: Putty Will Be Supplied By Owner Free Of Cost. 58 Supplying And Fixing Of Gi Route Marker 59 Suppplying Cable Route Marker With 10 Cm X 10 Cm X 5 Mm Thick Gi Plate With Inscription Thereon, Bolted / Welded To 35 Mm X 35 Mm X 6 Mm Angle Iron, 60Cm Long And Fixing The Same In Ground As Required. Job Includes Painting With One Coat Of Redoxide And Finishing Paint. 60 33Kv ( E ) / 22 Kv ( Ue ) Heat Shrinkable Straight Through Pvc / Xlpe Armoured Aluminium Cable Jointing ( Including Cost Of Jointing Kit ) : Making Straight Through Cable Joint For Power ( Pvc / Xlpe ) Armoured Cable And Following Sizes And Grade Including Cutting, Stripping Of Cable Insulation All Complete With Labour Including Travel, Transportation, Boarding And Lodging Of The Cable Jointer And Materials Excluding Cost Of Jointing Kit As Per Standard And Direction Of The Engineer-In-Charge. Note: Work To Be Done In Timeline As Mentioned In Tender Document. 61 3 X 400 Sqmm 62 Salt And Charcoal For Plate Earthing: Extra For Using Below Given Salt And Charcoal For Plate Earthelectrode As Required. 63 96 Kg Charcoal And 5 Kg Salt 64 240 Kg Coke And 5 Kg Salt 65 Salt And Charcoal For Pipe Earthing: Extra For Using Below Given Salt And Charcoal For Pipe Earth Electrode As Required. 66 64 Kg Charcoal And 5 Kg Salt 67 160 Kg Coke And 5 Kg Salt 68 Provide First-Aid Boxes 69 Supply And Fixing Of First-Aid Boxes As Per Ie Rules, 1956 Clause 43 ( 2 ) , Including Necessary Clamps, Bolts, Rawl Plugs, Etc. Breachking And Making Good The Walls If Required. All Complete With Labour And Materials As Per The Direction Of Engineer-In-Charg 70 Fire Buckets 71 Supply And Installation Of Set Of 3 Nos. Fire Buckets On A Suitable Stand Including Fabrication And Erection Of Iron Stand And Painting Of Stand And Buckets, All Complete With Labour And Materials As Per The Direction Of Engineer-In- Charge 72 Providing And Fixing Following Rating Metal Clad, Tp&N Switch Fuse Unit, 415 / 500 Volts, Without H.R.C. Fuses Including Drilling Holes On The Board, Connections, Earthing The Body Etc. As Required. 1.Isi Marked Hrc Fuses Shall Be Used. 2.Tpn Of English Electric / L&T / Crompton / Havells / Standard Make Shall Be Used. 73 16 A Tpn Hrc Sfu 74 32 A Tpn Hrc Sfu 75 63 A Tpn Hrc Sfu 76 100 A Tpn Hrc Sfu 77 L Series Mcb Suitable For Lighting And Other Domestic Loads: Supplying And Fixing Of Following Rating 240 Volts, 50Hz, 10Ka L Series, Miniature Circuit Breacker ( Suitable For Lighting And Other Domestic Loads And Conforming To Is 8828: 19 ) Of Single Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Note: Isi Marked Mcbs Of Havells / Loadster / Indo Kopp Make Shall Be Used. 78 5 To 32 Amp 79 40 Amp 80 5 A To 32 A G Series Mcb Suitable For Motorl And Other Inductive Loads: Supplying And Fixing 5 Amps. To 32 Amps. Rating, 240 / 415 Volts, 50Hz, 10Ka G Series, Miniature Circuit Breaker ( Suitable For Motor And Other Inductive Loads And Conforming To Is 8828: 1996, Iec 60898: 2002 ) Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Note: Isi Marked Mcbs Of Havells / Loadster / Indo Kopp Make Shall Be Used. 81 Single Pole 82 Single Pole And Neutral 83 Double Pole 84 Triple Pole 85 Triple Pole And Netural 86 Four Pole 87 40 A To 63 A G Series Mcb Suitable For Motorl And Other Inductive Loads: Supplying And Fixing 40 Amps. To 63 Amps. Rating, 240 / 415 Volts, 50Hz, 10Ka G Series, Miniature Circuit Breaker ( Suitable For Motor And Other Inductive Loads And Conforming To Is 8828: 1996, Iec 60898: 2002 ) Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Note: Isi Marked Mcbs Of Havells / Loadster / Indo Kopp Make Shall Be Used. 88 Single Pole And Neutral 89 Double Pole 90 Triple Pole And Netural / 4 Pole 91 Sp & Dp Mcb Isolator: Supplying And Fixing Following Rating, Single Pole & Double Pole Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Note: Isi Marked Isolators Shall Be Used. 92 40 Amps. Single Pole 93 63 Amps. Single Pole 94 40 Amps. Double Pole 95 63 Amps. Double Pole 96 80 Amps. Double Pole 97 100 Amps. Double Pole 98 125 Amps. Double Pole 99 Tp & Fp Mcb Isolator: Supplying And Fixing Following Rating, Three Pole And Four Pole, 415 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Note: Isi Marked Isolators Shall Be Used. 100 40 Amps. Triple Pole 101 63 Amps. Triple Pole 102 80 Amps. Triple Pole 103 100 Amps. Triple Pole 104 125 Amps. Triple Pole 105 40 Amps. Four Pole 106 63 Amps. Four Pole 107 80 Amps. Four Pole 108 100 Amps. Four Pole 109 125 Amps. Four Pole 110 Double Pole Rccb: Supplying And Fixing Following Rating, Double Pole, ( Single Phase Neutral ) , 240 Volts, Residual Current Circuit Breaker ( Rccb ) , Isi Marked, Having A Sensitivity Current Indicated Miliamperes In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Note: Isi Marked Rccb Shall Be Used. 111 16 Amps., 30 Ma 112 16 Amps., 100 Ma 113 16 Amps., 300 Ma 114 25 Amps., 30 Ma 115 25 Amps., 100 Ma 116 25 Amps., 300 Ma 117 32 Amps., 30 Ma 118 32 Amps., 100 Ma 119 32 Amps., 300 Ma 120 40 Amps., 30 Ma 121 40 Amps., 100 Ma 122 40 Amps., 300 Ma 123 63 Amps., 30 Ma 124 63 Amps., 100 Ma 125 63 Amps., 300 Ma 126 Four Pole Rccb: Supplying And Fixing Following Rating, Four Pole, ( Three Phase And Neutral ) 415 Volts, Residual Current Circuit Breaker ( Rccb ) , Isi Marked, Having A Sensitivity Current Upto Indicated Milliamperes In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Note: Isi Marked Rccb Shall Be Used 127 25 Amps., 30 Ma 128 25 Amps., 100 Ma 129 25 Amps., 300 Ma 130 40 Amps., 30 Ma 131 40 Amps., 100 Ma 132 40 Amps., 300 Ma 133 63 Amps., 30 Ma 134 63 Amps., 100 Ma 135 63 Amps., 300 Ma 136 Supply & Instln. Of Fuse Parts: Supply, Fixing And Connection Of Following Knife Type Hrc Fuse Link As Per Is:13703:1993 & Iec 269:1986 Of M / S Havell / L&T / G Ec Astholm / Standard / Mds Make Or Approved Equivalent In Distribution Board Etc.All Complete With Labour And Materials As Per Direction Of Engineer-InCharge. 137 Knife Type 6-100 Amp ( Fcd00 Series ) 138 Knife Type 125 Amp ( Hcd00 Series ) 139 Knife Type 32-125 Amp ( Hcd-1 Series ) 140 Bolted Type 2-32 Amp ( Hns Series ) 141 Boltedtype 6-32 Amp ( Htia Series ) 142 Boltedtype 80-125Amp ( Htsd Series ) 143 Supply And Fixing Of Equipment In Panels: Supply, Fixing And Connection Of Following Equipments In Panels Including Small Mechanical Works And Supply Of All Fixing Materials. All Complete With Labour And Materials As Per The Direction Of Engineer-In-Charge 144 Control Contactors- 4 Contacts For Ac Control Standard Coil Voltage - 25, 110, 240, 415, 50Hz Type Mm00 Of L&T Equivalent 145 Control Contactors- 8 Contacts For Ac Control Standard Coil Voltage - 25, 110, 240, 415, 50Hz Type Mm01 Of L&T Equivalent 146 Control Contactors- 4 Contacts For Dc Control Standard Coil Voltage - 24, 110, 220 Type Mm00 Of L&T Or Equivalent 147 Control Contactors- 4 Contacts For Dc Control Standard Coil Voltage - 24, 110, 220 Type Mm01 Of L&T Or Equivalent 148 Power Contactor ( With 1No + 1Nc ) - Upto 25 Amp ( Ac3 ) For Ac Standard Coil Voltage - 110, 220, 240, 415 V, 50Hz Type Mnx25 Of L&T Or Equivalent 149 Power Contactor ( Upto 2No + 2 Nc ) - Above 25 Amp But Upto 45 Amp ( Ac3 ) For Ac Standard Coil Voltage - 110, 220, 240, 415 V, 50Hz Type Mnx45 Of L&T Or Equivalent 150 Power Contactor ( Upto 2No + 2 Nc ) - Above 45 Amp But Upto 140 Amp ( Ac3 ) For Ac Standard Coil Voltage - 110, 220, 240, 415 V, 50Hz Type Mnx140 Of L&T Or Equivalent 151 Power Contactor ( Upto 2No + 2 Nc ) - Above 140 Amp But Upto 400 Amp ( Ac3 ) For Ac Standard Coil Voltage -110, 220, 240, 415 V, 50Hz Type Mnx400 Of L&T Or Equivalent 152 Thermal Relays Type Mnxr3 With Single Phasing Protection - 0.2 - 0.33 A To 14 -23A ( Direct Operated ) 153 Thermal Relays Type Mnxr4 With Single Phasing Protection - 20-33 To 30.0 - 50.0 A ( Direct Operated ) 154 Thermal Relays Type Mnxr4 With Single Phasing Protection -45-75 To 66-110 A ( Direct Operated ) With Separate Mounting 155 Thermal Relays Type Mnxr5l With Single Phasing Protection - 42 - 69 A To 180 - 300 A ( Ct Operated ) With Separate Mounting 156 Thermal Relays Type Ml0 / Ml1 / Ml1.5 - 0.15 - 0.25 A To 10.0 - 16.0 A ( Direct Operated ) Contractor 157 Thermal Relays Type Ml2 / Ml3 - 9.0 - 14.0 A To 28.0 - 42.0 A ( Direct Operated ) Contractor 158 Shrouded Push Button Actuator Of L&T Make Tk-3 ( Ss 91519 ) Or Approved Equivalent Of Any Color ( Green, Black, Red, Yellow, Grey Or Blue ) . 159 Automatic Ac Ammeter ( Automatic Electric Make Or Approved Equivalent ) 96 Mm X 96 Mm Square Type Block Backalite Case / Flush Mounting / Moving Iron / Spring Controlled Suppressed Scale, Ct Operated Ac Ammeter / Range 0-300- 1800 A, Ct Ratio 300 / Ia / Accuracy + / -2.5%. 160 Automatic Ac Volt Meter ( Automatic Electric Make Or Approved Equivalent ) 96 Mm X 96 Mm Square Type Block Backalite Case / Flush Mounting Ac Volt Meter / Range 0-600 Accuracy + / -2.5%. 161 Installation Of Current Transformer Of Any Rating 162 Timer For Auto Lux Switch 163 Supply And Installation Of Timer Of Approved Make For Autolux Switch As Per Secpfication And Direction Of The Engineer-In-Charge 164 Rcbo: Supply, Fixing And Connection Of Following 240 / 415V, 50Hz, With 10Ka Short Circuit Capacity Residual Current Circuit Breaker With Overload And Short Circuit Protection ( Confirming To Is 12640-2:2001 & Iec 61009-2-1 ) Of L&T / Gec Astholm / Standard / Mds / Datar / Havles Make Or Approved Equivalent In Distribution Board Etc. All Complete With Labour And Materials As Per Direction Of E-I- C 165 Double Pole ( Four Module - 25 A ( Sensitivity 30 Ma ) 166 Double Pole ( Four Module - 25 A ( Sensitivity 100 Ma ) 167 Double Pole ( Four Module - 25 A ( Sensitivity 300 Ma ) 168 Double Pole ( Four Module - 40 A ( Sensitivity 30 Ma ) 169 Double Pole ( Four Module - 40 A ( Sensitivity 100 Ma ) 170 Double Pole ( Four Module - 40 A ( Sensitivity 300 Ma ) 171 Supply & Installation Of Mccb: Supply & Installation Of M / S L&T / English Electric / Siemens Make T.P. Molded Case Circuit Breaker ( Mccb ) ( Confirming To Is 8828:1996, Iec 60898:2002 ) Of Following Current And Breaking Capacity Rating Suitable For 415V, 3Ph, 50 C / S Ac Supply Must Be Accompanied With Performance Test Certificates From Manufacturer. The Mccb Should Be Supplied With Thermal Overload Relay And Magnetic Release. 172 10 / 15 / 20 / 30 / 40 / 50 / 60 / 63 / 75 / 90 / 100 A With Icu = 10Ka 173 110 / 125 / 140 / 150 A With Icu = 10Ka 174 125 / 140 / 150 / 160 / 175 / 200 / 225 A With Icu = 25Ka 175 250 / 300 / 350 / 400 A With Icu = 35Ka 176 Supply & Installation Of Led Indication Lamps: Supply And Fixing Of Led Indication Lamp In The Panels. Leds Shall Be Provided With Leakage Voltage Protection Upto 40V. Operating Voltage Shall Be 110V / 220V / 230V / Ac / Dc, Panel Cutouts Shall Be 22.5 / 25.5 / 30.5 Mm. Terminals Shall Be Shrouded For Finger Proofing And Safety Are With Captivated Washers To Hold Two Lugged ( Fork / Pin ) Wires In One Terminal. Job Includes Supply Of Labor And Various Undry Materials Required And Finally Testing Of LedS For + Following EdS 177 Red / Yellow / Amber / Green / Milky White LedS 178 Blue Led 179 Supply & Instln. Of Industerial Type Plug And Sockets : Supply, Fixing And Connection Of Following Inusterial Type Plugs / Sockets ( Confirming To Is / Iec-309 ) Of M / S Havell / L&T / G Ec Astholm / Standard / Mds Make Or Approved Equivalent In Distribution Board Etc.All Complete With Labour And Materials As Per Direction Of Engineer-In-Charge 180 Plug- 2 Pole+ Earth, 250V- 20 Amp 181 Plug- 3 Pole+ Earth, 440V- 20 Amp 182 Socket- 2 Pole+ Earth, 250V- 20 Amp 183 Socket- 3 Pole+ Earth, 440V- 20 Amp 184 Supply And Fixing Of Recessedmetal Boxes With Phenolic Sheet: Supply And Fixing Of Metal Box Of Following Size ( Nominal ) In Recess With Suitable Size Of Phenolic Laminated Sheet Cover In The Front Including Painting Etc. As Required. 185 75 Mm X 75 Mm X 60 Mm Deep 186 100 Mm X 100 Mm X 60 Mm Deep 187 150 Mm X 75 Mm X 60 Mm Deep 188 150 Mm X 150 Mm X 60 Mm Deep 189 180 Mm X 100 Mm X 60 Mm Deep 190 200 Mm X 125 Mm X 60 Mm Deep 191 200 Mm X 150 Mm X 60 Mm Deep 192 200 Mm X 150 Mm X 75 Mm Deep 193 200 Mm X 250 Mm X 75 Mm Deep 194 200 Mm X 150 Mm X 100 Mm Deep 195 Gi Cable Tray 196 Supply, Installation & Fixing Of Prefabricated Perforated Gi Cable Trays With Tray Cover Of Width 150 Mm, 300 Mm, 450 Mm & 600 Mm As Per Site Requirement For Laying Of Cables With Standard Rung Spacings. Load For Support Span Of 2.5 Meter As 30, 60, 75 & 90 ( In Kg / Mtr ) Respectively With Concentric Static Load As 70 Kg At The Centre, With Materials, Labour, Tools And Tackles, Consumables Etc , As Per Directions Of Site Engineer / Engineer-In-Charge. 197 Aluminium Cable Tray 198 Supply, Installation & Fixing Of Prefabricated Perforated Aluminium Cable Trays With Tray Cover Of Width 150 Mm, 300 Mm, 450 Mm & 600 Mm As Per Site Requirement For Laying Of Cables With Standard Rung Spacings. Load For Support Span Of 2.5 Meter As 30, 60, 75 & 90 ( In Kg / Mtr ) Respectively With Concentric Static Load As 70 Kg At The Centre, With Materials, Labour, Tools And Tackles, Consumables Etc , As Per Directions Of Site Engineer / Engineer-In-Charge. 199 Supply Erection And Installation Of Cable Conduits Made Up Of Gi Pipes Of Medium Class, Subject To OwnerS Approval, In Already Made Trenches, On Walls, Concrete Structures Etc. Including Supply And Installation Of All The Necessary Pipe Fittings Such As Bends, Sockets, Elbows, Tees, Etc. The Job Also Includes Bending, Threading, Binding, Clamping, Providing Spacere, Plugs, Packings, Bushing Etc. As Required For Laying Of Cables, Complete In All Respects Including Consumables, Tools / Equipments And Labour A Per Directions Of Engieer-In-Charge / Site Engineer. 200 Gi Pipe With Diameter 20 Mm 201 Gi Pipe With Diameter 25 Mm 202 Gi Pipe With Diameter 37 Mm 203 Gi Pipe With Diameter 100 Mm 204 Ht Cable Termination ( 6.6 / 11 Kv ) - Supply, Termination And Connection Of Xlpe Cable Termination Kit ( Indoor Type ) , Heat Shrinkable Sleeve Type Of Raychem / M-Seal / Cci Make With All Accessories, Including Cutting ( Tools And Accessories For Termination Should Meet The Selected Standards ) , Stripping Of Cable Insulation Providing Copper Cable End Lugs And Cable Glands As Required, Restoration Of Insulation, Supplying And Providing The Cable Supporting Clamps, Straps, Cable Tags Connection To The Terminals Of Ht Panel, Vfds, Isolators, Transformer, Dg, Mlpu / Booster Pump Motors Etc., Earthing Of Armouring, Materials, Labour, Tools And Tackles, Consumables Etc , As Per Directions Of Site Engineer / Engineer-In-Charge: 205 Ht Cable Of Size Above 3Cx240 Sq. Mm 206 Ht Cable Of Size Upto 3Cx240 Sq. Mm 207 Lt Cable End Termination For Armoured Pvc Insulated Aluminium Cable With Doublecompression Flame Proof Type Brass Glanding ( Including Cost Of Glands & Lugs ) : Providing End Termination Of Power / Control Cable Including Cutting, Stripping, Providing & Fixing Lugs, Cable Insulation, Providing & Glanding Double Compression Heavy Duty Flame Proof Type Brass Cable Gland Conforming To Is-12943 ( DowellS Or Approved Equivalent ) , Wherever Specified, Providing Aluminium Lugs, Crimping / Soldering, As Necessary, Restoration Of Insulation / Clamping Of Cable, Tagging With Aluminium Tag, Earthing Of Armour, Connection To The Equipment Terminals Etc. All Complete With Labour And Materials As Per Standard And Direction Of The Engineer-Incharge 208 2 X 6 Sqmm 209 2 X10sqmm 210 2 X16sqmm 211 3 X 4 Sqmm 212 3 X 6 Sqmm 213 3 X 10 Sqmm 214 3 X 16 Sqmm 215 3 X 25 Sqmm 216 3 X 35 Sqmm 217 3 X 50 Sqmm 218 3 X 70 Sqmm 219 3 X 95 Sqmm 220 3 X 120 Sqmm 221 3 X 150 Sqmm 222 3 X 185 Sqmm 223 3 X 225 Sqmm 224 3 X 240 Sqmm 225 3 X 300 Sqmm 226 3-1 / 2 X 25 Sqmm 227 3-1 / 2 X 35 Sqmm 228 3-1 / 2 X 50 Sqmm 229 3-1 / 2 X 70 Sqmm 230 3-1 / 2 X 95 Sqmm 231 3-1 / 2 X 120 Sqmm 232 3-1 / 2 X 150 Sqmm 233 3-1 / 2 X 185 Sqmm 234 3-1 / 2 X 225 Sqmm 235 3-1 / 2 X 240 Sqmm 236 3-1 / 2 X 300 Sqmm 237 Lt Cable Heat Shrinkable Indoor / Outdoor Cable End Termination ( Including Cost Ofend Termination Kit ) : Providing End Termination Of Power Cable Including Cutting, Stripping, Providing Lugs, Cable Insulation, Providing And Glanding With Single / Double Compression Heavy Duty Brass Cable Gland Conforming To Is-12943 , Wherever Specified, Providing Aluminium Lugs, Crimping / Soldering, As Necessary, Restoration Of Insulation / Clamping Of Cable, Tagging With Aluminium Tag, Earthing Of Armour, Connection To The Equipment Terminals Etc. All Complete With Labour And Materials As Per Standard And Direction Of The Engineer-In-Charge. Make Of Kits Shall Be Of Raychem / Cci / Approved Equivalent Make 238 Upto 3 / 3.5 / 4 X 10 Sqmm 239 3 / 3.5 / 4 X 16 Sqmm 240 3 / 3.5 / 4 X 25 Sqmm 241 3 / 3.5 / 4 X 35 Sqmm 242 3 / 3.5 / 4 X 50 Sqmm 243 3 / 3.5 / 4 X 70 Sqmm 244 3 / 3.5 / 4 X 95 Sqmm 245 3 / 3.5 / 4 X 120 Sqmm 246 3 / 3.5 / 4 X 150 Sqmm 247 3 / 3.5 / 4 X 185 Sqmm 248 3 / 3.5 / 4 X 225 Sqmm 249 3 / 3.5 / 4 X 240 Sqmm 250 3 / 3.5 / 4 X 300 Sqmm 251 Ht Cable Joint 252 Making Straight-Through Joint On 6.6 / 11 Kv Aluminium / Copper Xlpe / Pvc Insulated Armoured Screened Cable, Including The Supply Of Required Materials Such As Cable Jointing Kit ( Of Heat Shrinkable Sleeve Type Of Raychem / M-Seal / 3M ) , Materials, Labour, Tools And Tackles, Consumables Etc , As Per Directions Of Site Engineer / Engineer-In-Charge: For Cables Of Size Upto 3 Core X 400 Sqmm 253 Lt Cable Joint ( 1.1 Kv ) - Making Straight Through Joints On Al / Cu Conductor Xlpe / Pvc Insulated Armoured Cable Including The Supply Of Required Materials Such As Cable Jointing Kit ( Of Heat Shrinkable Sleeve Type Of Raychem / Mseal / 3M ) , Materials, Labour, Tools And Tackles, Consumables Etc , As Per Directions Of Site Engineer / Engineer-In-Charge: 254 Power Cables Lt : Od Upto 20 Mm 255 Power Cables Lt : Od Above 20 Mm And Upto 40 Mm 256 Power Cables Lt : Od Above 40 Mm And Upto 60 Mm 257 Power Cables Lt : Od Above 60 Mm 258 Control Cables Lt : Od Upto 20 Mm 259 Earthing System Set ( 06 Pits ) 260 Supply, Installation, Testing Of Earthing System Consisting Of 6 Earth Pits Of Perforated Gi Pipes Earthing Electrodes And Copper Plate Terminal Block Including Construction Of Chamber Using Cement Concrete With Earthing Pit Cover And Frame, Supply Of Charcoal, Salt Etc Including Supply Of Interconnecting Cables / Strips Including Necessary Welding Etc Complete As Per Directions Of The Site Engineer, Including Cost Of Tools, Materials Etc Complete In All Respects. The Job Shall Also Include Testing Of Each Earth Pit And The Entire Earthing System On Whole. ( Note: Earthing For Field Instruments Shall Be Provided From Station Earth Grid Covered In Electrical Sor. ) 261 Earthing System Set ( 03 Pits ) 262 Supply, Installation, Testing Of Earthing System Consisting Of 3 Earth Pits Of Perforated Gi Pipes Earthing Electrodes And Copper Plate Terminal Block Including Construction Of Chamber Using Cement Concrete With Earthing Pit Cover And Frame, Supply Of Charcoal, Salt Etc Including Supply Of Interconnecting Cables / Strips Including Necessary Welding Etc Complete As Per Directions Of The Site Engineer, Including Cost Of Tools, Materials Etc Complete In All Respects. The Job Shall Also Include Testing Of Each Earth Pit And The Entire Earthing System On Whole. ( Note: Earthing For Field Instruments Shall Be Provided From Station Earth Grid Covered In Electrical Sor. ) 263 Chemical Earthpit 264 Supply, Installation, Testing And Commissioning Of Ace ( Artificial Concept Of Earthing With Chemical Rod ) Chemrod Earthing Electrode By Digging Earthing Item Includes The Supply And Installation Of The Ci / Rcc Cover In The Earth Pit, Backfilling Etc. And Construction Of Chamber; Complete Including Excavation, Backfilling And Supply Of All Materials Required For Making Earth Pit As Per Directions Of The Site Engineer, Including The Cost Of All Labour, Tools, Materials Etc. Complete In All Respects. 265 Lightining Arrestor 266 Supply, Installation And Testing Of Lightning Arrestor On Top Of The Mov Buiding Or Mov Cp Buiding For Diverting Lightning Surges To The Ground. The Work Shall Include Supply Of 1.2 Meter Long Copper Lightning Arrestor With 5 Spronged Phenyl Rod Base Plate Etc. Complete With Necessary Insulators Including Supply And Fixing Of 50 X 6 Mm Gi Earthing Strip Of Required Length And Connection To The Main Earthing Grid. 267 Rewiinding Of Fans: Rewinding Of Ceiling / Pedestal / Exhaust / Air Circulator Fans Of All Types / Sizes / Make Including 1-Phase And 3-Phase Type Exhaust Fans Max. Upto 2.2 Kw Capacity And Supply Of Super Enameled Winding Wire ( Devi Dayal Make, Isi Marked Insulation Materials Required ) . This Also Includes Replacement Of Single / Double Bearing Skf Make / Bushes ( As Per Original Make ) And Overhauling Of Fan And All Jobs Related To Complete This Work In Totality. This Also Includes Removal Of Fans From Site, Installation And Commissioning After Testing Of Rewound Fans And Replacement Of Condenser, If Required. This Also Includes Transportation From Site After Dismantling To Contractor’S Workshop And Back To Site. Note: Contractor Has To Give Guarantee For Rewinding Of Above Items For A Period Of Six Months And If Winding Is Burnt Again Within Six Months Of Working Of Fans, It Has To Be Rewound Again Free Of Cost Of Contractor. The Burnt Winding Shall Be Kept By Contractor. 268 Ceiling / Pedestal Fans 269 Exhaust / Air Circulators Fans. 270 Overhauling Of Exhaust / Air Circulator Fans : Overhauling Of Exhaust / Air Circulator Fans Of Various Types / Sizes Makes And Its Bearings Including Removal From Site, Cleaning, Greasing After Degreasing, Assembling And Fixing In Position, Testing And Commissioning Including Transportation From Site To Workplace And Back All Complete With Labour And Materials As Per Directions Of Engineer-InCharge. 271 Excluding The Cost Of Bearings ( Bearings If Necessary Will 272 Including Supply And Fixing Of Bearings Of Skf Make ( 2Nos. Bearings ) 273 Overhauling Of Ceiling / Pedestal Fans : Overhauling Of Ceiling / Pedestal Fans Of Various Types / Sizes / Make And Its Bearings Including Removal From Site, Cleaning, Greasing After Degreasing, Assembling And Fixing In Position, Testing And Commissioning Including Transportation From Site To Workplace And Back. All Complete With Labour And Materials As Per Directions Of Engineer-InCharge. 274 Excluding The Cost Of Bearings. ( Bearings If Necessary Will Be Supplied By Owner Free Of Cost. 275 Including Supply And Fixing Of Bearings Of Skf Make And Bushes ( As Per Original Make ) Of Both Sides By Contractor. 276 Erection Of Metallic Street Light: Erection Of Metallic Steet Light Standard Of Following Length In Cement Concrete 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 40 Mm Nominal Size ) Foundation With Cement Concrete Collar Of Size 0.4 M Dia X 0.5 M Height To Accommodate The Looping Type Cable End Box Including Excavation And Refilling Etc. As Required. 277 4.5 M But Upto 6.5 M 278 6.5 M But Upto 8 M 279 Supply, Erection And Installation Of Strain Insulators, Post Insulators, Acsr Dog Conductor, Connectors, Shield Wire, Etc For Outdoor Switchyard. The Job Also Includes Assembling As Required, Installation On Already Made Concrete Foundations Or Fixing To Walls Or Steel Structures Or Fixtures, Aligning, Levelling, Groutting Assembling And Fittings All Accessories Etc. Supplied Separately, Complete In All Respects Including Consumables Tools / Equipments And Labour As Per Directions Of Engieer-In-Charge / Site Engineer. 280 Strain Insulators For 33 Kv 281 Acsr Dog Conductors For 33 Kv 282 Connectors For 33 Kv 283 Shield Wire For 33 Kv 284 Post Insulators For 33 Kv 285 Supply And Fixing Of Street Light Bracket With Controlling Switch 286 Supplying And Fixing Of 20Mm Dia. G.I. Pipe For Street Light Water Tight Bracket Including Bending To Shape, 40Mm X 3Mm Flat Iron Clamps And Wiring With 1.5 Sq.Mm. W.P. / Pvc Wire Alongwith Water Proof Controlling Switch And Painting The Flat Iron With Primer And Finish Paint Etc. As Required. 287 33 Kv Stay Set 288 Supplying And Erection Of Galvanised Stay Set For 33 Kv Overhead Line Complete With 19 / 20Mm. Dia X 1.8 Metres Long Stay Road, Anchor Plate Of Size 45 Mm X 45 Cm X 7.5 Mm Thick Thimble, Stay Clamps, Turn Buckle ( 20Mm X 600Mm ) , 7 / 4.00Mm. Dia G.I. Stay Wire And 33 Kv Strain Insulator Etc. In Cement Concrete 136 ( 1 Cement 3 Coarse Sand 6 Graded Stone Aggregate 40Mm. Nominal Size ) Foundation Including Excavation And Refilling Etc. As Required. 289 Louvers / Shutters Of Exhaust Fan 290 Fixing Of Louvers / Shutters Complete With Frame For Exhaust Fan Of All Sizes 291 Supplying And Fixing Ceiling Fan: Supply, Installation, Testing & Commissioning Of Ceiling Fans Of Bajaj / Crompton Greaves / Khaitan / Usha Make Only Including Supply And Fixing Of The Electronic Regulators With All Necessary Supports. All Complete With Labour And Material, Specification And Direction Of Engineer In Charge 292 1200Mm Sweep ( White ) 293 1400Mm Sweep ( White ) 294 Supplying And Fixing Wall Mounted Fan: Supply, Installation, Testing And Commissioning Of Wall Mounted Fans Of Bajaj / Cromptonreaves / Khaitan / Usha Make Only Including Supply And Fixing Of The Electronic Regulators With All Necessary Supports. All Complete With Labour And Materials As Per Directions Of Engineer-In-Charge.. Note: Necessary Civil Works Required For Fixing The Exhaust Fans Shall Be In The Scope Of Contractor. 295 Osc. Wall & Cabin Fans Of 300Mm Sweep 296 Osc. Wall & Cabin Fans Of 450Mm Sweep 297 Steel Structural Works 298 Supply, Fabrication, Erection, Installation Of Steel Structural Works Of Any Type And Shape Such As Cable Raks, Cable Trays, Push Button Control Posts Etc., As Required Job Complete In All Respects Including The Cost Of All Labour, Tools, Material Etc., Complete.And As Per Specifications And Directions Of Site Engineer / Engineer-In-Charge. 299 Flp / Wp Push Button Station - Supply , Erection, Testing And Commissioning Of Flp / Wp Push Button ( On / Off ) Control Station Of Approved Make With / Without Ammeter For The Motor Off Control At Field Including Connection And Termination Of Copper Control Cable, Fabricating, Earthing The Supporting Structure, Painting The Same, Including Supply & Installation Of Double Compression Cable Glands & Flame Proof Plugs For Sealing All Spare Entries Including The Cost Of All Labour, Tools, Materials Etc. Complete In Every Respect As Per The Specification And Directions Of The Site Engineer / Engineer-In-Charge Including The Cost Of All Labour, Tools, Materials Etc. Complete In Every Respect As Per The Specification And Directions Of The Site Engineer / Engineer-In-Charge: 300 With Ammeter 301 Without Ammeter 302 Flame Proof Fittings - All Equipment Under This Category Shall Be Suitable ( Minimum Requirments ) For Location In Zone-I Gas Group Iia & Iib ( Temp. Class T3 ) Area With A Separate Terminal Box For Incoming Cable And A Separate Terminal Box For Out Going Cable ( Where Applicable ) , Apart From Separate Enclosure For Each Equipment Including Control Gear Etc. In Ip 65 Cast Aluminium Lm-6 Certified Enclosure: 303 Flameproof Tubelight, 2X22watt, Led, Suitable For Exd Gas Group Ii C, As Per Is / Iec 60079-2007 304 Flameproof Led Well Glass Fitting 90 W, Supply, Installation, Testing & Commissioning Of ExD ( Flameproof ) Well Glass Light Fixture With Provision Of Cable Entries: 2 Nos. X 3 / 4 Et, Cable Glands: 2 Nos. X 3 / 4 Et ( Max. Od 20Mm ) - ExD ( Iia / Iib ) , Double Compression Type, Brass Nickel Plated With Pvc Hood. Blanking Plug: 1 No. X 3 / 4 Et - ExD, Brass Nickel Plated. Gasket: Neoprene, Hardware: Ss 304, Earthing: External 2 Nos. ( M6 ) , Internal 1 No. ( M5 ) , And As Per Directions Of Eic. 305 Flameproof Led Flood Light Fitting 90 W, Supply, Installation, Testing & Commissioning Of ExD ( Flameproof ) Flood Light Fixture With Provision Of Cable Entries: 2 Nos. X 3 / 4 Et, Cable Glands: 2 Nos. X 3 / 4 Et ( Max. Od 20Mm ) - ExD ( Iia / Iib ) , Double Compression Type, Brass Nickel Plated With Pvc Hood. Blanking Plug: 1 No. X 3 / 4 Et - ExD, Brass Nickel Plated. Gasket: Neoprene, Hardware: Ss 304, Earthing: External 2 Nos. ( M6 ) , Internal 1 No. ( M5 ) , And As Per Directions Of Eic. 306 Flameproof Led Flood Light Fitting 45 W, Supply, Installation, Testing & Commissioning Of ExD ( Flameproof ) Flood Light Fixture With Provision Of Cable Entries: 2 Nos. X 3 / 4 Et, Cable Glands: 2 Nos. X 3 / 4 Et ( Max. Od 20Mm ) - ExD ( Iia / Iib ) , Double Compression Type, Brass Nickel Plated With Pvc Hood. Blanking Plug: 1 No. X 3 / 4 Et - ExD, Brass Nickel Plated. Gasket: Neoprene, Hardware: Ss 304, Earthing: External 2 Nos. ( M6 ) , Internal 1 No. ( M5 ) , And As Per Directions Of Eic. 307 Flameproof Led Well Glass Fitting 125 W, Supply, Installation, Testing & Commissioning Of ExD ( Flameproof ) Well Glass Light Fixture With Provision Of Cable Entries: 2 Nos. X 3 / 4 Et, Cable Glands: 2 Nos. X 3 / 4 Et ( Max. Od 20Mm ) - ExD ( Iia / Iib ) , Double Compression Type, Brass Nickel Plated With Pvc Hood. Blanking Plug: 1 No. X 3 / 4 Et - ExD, Brass Nickel Plated. Gasket: Neoprene, Hardware: Ss 304, Earthing: External 2 Nos. ( M6 ) , Internal 1 No. ( M5 ) , And As Per Directions Of Eic. 308 Critical Light: Flame Proof & Weather Proof Supply, Erection ( Fixing The Same On Roof Truss, Wall, Column Etc. As Required ) , Termination Of 240V, Flame Proof Light Fittings With Heat Resistant Glass Diffuser And Suitable For Led Lamp, Ip65, Of Model Pel 111 Prolite Make Or Equivalent Approved Makes As Per Eic. The Job Includes The Cost Of Fitting And Erection 1 No. Led Lamp 18W, Ni-Cd Battery Of Suitable Size For Minimum 01 Hour Back Up, Battery Charger, Earthing, Supply & Erection Of All Accessories, Suitable Ms Brackets Etc. Complete. 309 Flp & Wp Junction Box - Supply, Erection, Installation, Testing And Commissioning Of Flameproof & Weather Proof Junction Box For Providing Cable Termination Of Motor, Including Connection And Termination Of Earthing Wire And Conduits Etc., Including Supply & Installation Of Double Compression Cable Glands & Flame Proof Plugs For Sealing All Spare Entries Complete As Per Direction Of The Site Engineer, Including The Cost Of All Labour, Tools, Consumable Materials Etc., Complete In All Respect: 310 8 Way Junction Box With 8 Cable Entries ( 1 X 1 & 7 X 3 / 4 ) At Bottom & 20 Nos. Terminals. 311 6 Way Junction Box With 6 Cable Entries ( 6 X 3 / 4 ) At Bottom & 20 Nos. Terminals. 312 4 Way Junction Box With 4 Cable Entries ( 4 X 3 / 4 ) At Bottom & 20 Nos. Terminals. 313 Exhaust Fan - Supply, Installation, Testing Of Single Phase 230 V, Industrial Type Heavy Duty Exhaust Fan Of Gec / Usha / Crompton Greaves Or Of Approved Make Fitted / Provided With Louvres, Supports Etc. Including Making The Required Opening On Walls, Fixing And Connecting The Wires Etc. Including Earthing The Body Of The Fan, Making Good The Opening On The Wall Etc. Complete As Per Direction Of Site Engineer Including The Cost Of All Labour, Tools, Materials Etc. Complete. 314 18 Sweep 315 12 Sweep 316 Flp / Wp Exhaust Fans: 317 Flame Proof, Weather Proof, Single Phase, 12 Exhaust Fan, Ip65, Lm6 Type Ef1001 Of Fcg Or Equivalent Alongwith Supporting Frame, Bolts, Louvers, Flame Proof Motor, Including Supply & Installation Of Double Compression Cable Glands & Flame Proof Plugs For Sealing All Spare Entries, Complete In All Respects 318 Flame Proof, Weather Proof, Single Phase, 12 Exhaust Fan, Suitable For Exd Gas Group Ii C, As Per Is / Iec 60079-2007, Ip65, Lm6 Type Ef1001 Of Fcg Or Equivalent Alongwith Supporting Frame, Bolts, Louvers, Flame Proof Motor, Including Supply & Installation Of Double Compression Cable Glands & Flame Proof Plugs For Sealing All Spare Entries, Complete In All Respects 319 Flp / Wp Rotary Switch: 320 Supply, Installation, Testing & Commissioning Of Flame Proof Weather Proof On / Off Rotary Switch , Ip65, Lm6, Including Including Supply & Installation Of Double Compression Cable Glands & Flame Proof Plugs For Sealing All Spare Entries Etc., Complete In All Respects. 321 Flp / Wp Distribution Boards - Supply, Erection, Installation, Testing And Commissioning Of Flameproof / Weather Proof ( Ip-65 ) Distribution Board As Per Technical Specification Of Types As Per Eic For Lighting Purpose In Mlpu / Booster Shed Etc., Including Connection And Termination Of Power Cables, Earthing Wire And Conduits Etc. Including Including Supply & Installation Of Double Compression Cable Glands & Flame Proof Plugs For Sealing All Spare Entriescomplete As Per Direction Of The Site Engineer, Including The Cost Of All Labour, Tools, Consumable Materials Etc. Complete In All Respect: 322 Outdoor Type, Floor Mounted, Flameproof, Weatherproof ( Ip 65 ) Lighting Distribution Board Type-I Db With Bus Bar - 100 A Tpn, Incomer - 1 No. 63 A Tpn Mcb & Outgoing - 9 No. 10 A Spn, Mcb 323 Outdoor Type, Floor Mounted, Flameproof, Weatherproof ( Ip 65 ) Lighting Distribution Board Type-Ii Db Having Bus Bar - 100 A Tpn, Incomer - 1 No. 32 A Tpn Mcb & Outgoing - 3 No. 6 A Spn Mcb 324 Flp / Wp Switch Cum Socket - Supply, Erection, Installation, Testing And Commissioning Of Flameproof / Weatherproof Switch Cum Socket / Welding Receptacle Of Approved Makes To Be Installed On Walls, Coloumns, Structures, Including Supply & Installation Of Double Compression Cable Glands & Flame Proof Plugs For Sealing All Spare Entries Etc., Including Connection And Termination Of Earthing Wire And Conduits., Etc. Complete As Per Direction Of The Site Engineer, Including The Cost Of All Labour, Tools, Consumable Materials Etc. Complete In All Respect: 325 250V, 15 A Switch Cum Socket With Plug 326 250V, 63 A Plug & Welding Receptacle 327 415V, 63A, Switch & Socket With Plug ( No. Of Pins 3P +N+ E ) , Model Epss 1563-61 Of Baliga Or Equivalent Approved Make 328 Wp 6 Way Junction Box: 329 Supply, Erection, Installation, Testing And Commissioning Of Weather Proof 6 Way Junction Box Of Approved Make For Providing Cable Termination & Including Connection And Termination Of Earthing Wire And Conduits, Including Supply & Installation Of Cable Glands & Plugs For Sealing All Spare Entries Etc. Complete As Per Direction Of The Site Engineer, Including The Cost Of All Labour, Tools, Consumable Materials Etc. Complete In All Respect. 330 Wp Push Button Station: 331 Supply, Erection, Testing And Commissioning Of Weather Proof Push Button ( Off ) Control Station Of Approved Make For Emergency Transformer Tripping At Field Including Connection And Termination Of Copper Control Cable, Fabricating, Earthing The Supporting Structure, Painting The Same, Including Supply & Installation Of Cable Glands & Plugs For Sealing All Spare Entries Including The Cost Of All Labour , Tools, Materials Etc. Complete In Every Respect As Per The Specification And Directions Of The Engineer-In-Charge. 332 Stainless Steel Inscription Plate : 333 Supply And Installation Of Approved Quality Stainless Steel Name Inscription Plates Including Anodising, Engraving The Inscriptions, Providing Screws, Etc. For Equipments Viz. Motors, Motor Control Centres, Switchgears, Push Button Stations Etc. As Required, Providing Necessary Holes Tapping Etc. And Fixing The Same Complete In All Respect As Per The Direction Of Site Engineer / Engineer-In-Charge Including The Cost Of All Labour, Tools Etc. 334 Plastic Inscription Plate : 335 Supply And Installation Of Approved Quality Plastic Name Inscription Plates Including Engraving The Inscriptions, Providing Screws, Etc. For Equipments Viz. Motors, Motor Control Centres, Switchgears, Push Button Stations Etc. As Required, Providing Necessary Holes Tapping Etc. And Fixing The Same Complete In All Respect As Per The Direction Of Site Engineer / Engineer-In-Charge Including The Cost Of All Labour, Tools Etc. 336 Point Wiring - Supplying, Installation And Testing With 1.5 Sq.Mm Stranded Pvc Insulated Copper Conductor Wires For Phase & Neutral Of 650V Grade Including Earthing By Providing 1.5 Sq.Mm Earth Insulated Continutity Wire Of Copper In Pvc Conduit ( Supply & Installation Of Pvc Conduit Covered Elsewhere In Sor ) Recessed On Wall / Ceiling / False Celing Including Supply & Installation Of Switch Boxes, Junction Boxes, Pull Boxes, Bushes, Screws, Check Nuts, Bends, Modular Switches And Sockets . The Circuit Wiring With 4 Sq.Mm Pvc Copper Wire From D.B. To Switchboard As Required Is Also In The Scope Of The Contractor: 337 1 Light Point Controlled By 1 Switch 338 16 A Power Plug Point Wiring: 339 Wiring For 250 V Single Phase And Neutral 16 Amps Modular Power Plug Point With Pvc Insulated 4 Sq. Mm. Copper Conductor Wires For Phase & Neutral, 650 V Grade Including Earthing, The Third Pin With 2.5 Sq. Mm Copper Conductor Earthing Insulated Continuity Wire, Complete With Providing And Fixing Of 6 Pin 16 / 6A Modular Socket And 20 / 10 A Modular Switch ( 1 Plug Point Per Circuit ) As Per Directions Of Site Engineer. 340 6 A Plug Point Wiring: 341 Wiring For 250 V Single Phase And Neutral 6 Amps Modular Plug Point With Pvc Insulated 2.5 Sq. Mm. Copper Conductor Wires For Phase & Neutral, 650 V Grade Including Earthing, The Third Pin With 1.5 Sq. Mm Copper Conductor Earthing Insulated Continuity Wire, Complete With Providing And Fixing Of 5 Pin 6A Modular Socket And 10 A Modular Switch ( 1 Plug Point Per Circuit ) As Per Directions Of Site Engineer. 342 Ac Point Wiring: 343 Point Wiring For Power Plug Point With 4 Sq.Mm Stranded Pvc Insulated Copper Wire Including Earthing The Third Pin With 2.5 Sq. Mm Copper Insulated Earthing Wire Complete With Supply And Fixing Of Recessed Mounted Industrial Type 3 Pin 32 A Metal Clad Socket And Plug, 20A Mcb ( Motor Duty ) Housed In A 16 Gauge M.S. Box 344 Lighting Distribution Board / Ac Distribution Board - Supply , Installation, Testing And Commissioning Of Tpn Lighting / Ac Distribution Board Of Approved Make, With Rating And Feeders As Per Specification. The Db Shall Be Of Ip-42 Protection Class And Shall Conform To Is 8623. The Board Shall Be Fitted With An Acrylic Door As Per Directions Of Site Engineer: 345 Type Vi Light Db: Euro Db Dboxx Of Havells Or Equivalent Make Complete With Bus Bar, Neutral Links, Earth Links Along With 1 X 6 A Mcb Spn , 7X2 A Spn Mcb, Digital Time Switch , 110 - 240 Vac 1 Phase - 2W, 1 C / O, Base / Din Based Upon Lat / Long Setting Of Location Working According Sunrise And Sunset And Mnx 9-2P Power Contactors 9 A 2 Pole 1 No Or 1 Nc Of L&T Or Equivalent. 346 Critical Light Db: Euro Db Dboxx Of Havells Or Equivalent Make Complete With Bus Bar, Neutral Links, Earth Links And 1 X 6 A Mcb Spn & 7X2 A Spn Mcb 347 Decorative Light Fittings - Supply, Installation, Connection, Earthing And Testing Of The Following Fittings, Including Supply And Installation Of Drop Pipes, Hooks, Fittings, Fixtures, Nuts, Bolts, Supports, On Walls, Outlet Box For Regulators And All Other Required Materials Etc. As Per Directions Of The Site Engineer Including Cost Of All Labour, Tools, Materials Etc. Complete In All Respects.Make Of The Fittings Can Be The Make Mentioned In The Respective Sor Items Or Equivalent Model: 348 Tube Light Fitting Type Quadra 2 Bbs805 2 X Llm 1800 / 840 Psu-E 220V-240V Led Luminaire Of Phillips Or Approved Make, Complete With All Accessories Suitable For Mounting In False Ceiling As Per The Directions By Eic / Site Engineer. 349 Led Ceiling Point: Supply And Fixing Of Surface Mounted Led Ceiling Light Fitting Type Mainstream Spot Aura 15W Of Phillips Or Equivalent Approved Make Complete With All Accessories Such As Led Module, Driver, Optics, Thermal Sink, Connector Blocks Etc Including Installation. 350 Wp Endura Led: Supply And Fixing Of Surface Mounted Weather Proof Endura Led Wt 550 Light Fitting Of Phillips Or Equivalent Approved Make Complete With All Accessories Such As Led Module, Driver, Optics, Thermal Sink, Connector Blocks Etc Including Installation. 351 Supply And Fixing Of Led Wall Light Cat. No. 35022 9W Fitting Of Phillips Or Equivalent Approved Make Complete With All Accessories Such As Led Module, Driver, Optics, Thermal Sink, Connector Blocks Etc Including Installation. 352 Led Light Fittings, Recess Mounting Type, Sereno Led-Rc869b Led 30S-6500 Pse W30l120 D8 Or Equivalent Approved Make With Leds: Supply And Fixing Of Recess Mounted Weather Proof Light Sereno Led-Rc869b Led 30S-6500 Pse W30l120 D8 Or Equiavlent Approved Make With Leds, 42 W Or More, Having 2950 Lumens Or More Output. Led Fitting Of Phillips Or Equivalent Approved Make Complete With All Accessories Such As Led Module, Driver, Optics, Thermal Sink, Connector Blocks Etc Including Installation With Led Of Approved Make. 353 Led Light Fittings With Leds, Sereno Led-Suspended-Sp824 P Led 30S-5000 Gr Od Or Approved Equivalent:Supply And Fixing Of Surface Mounted Weather Proof Light Sp824 P Led 42 W Having 2950 Lumens Output Fitting Of Phillips Or Equivalent Approved Make Complete With All Accessories Such As Led Module, Driver, Optics, Thermal Sink, Connector Blocks Etc Including Installation With Led Of Approved Make. 354 Led Light Fittings, Batten With 2Xtled-Tmc501-2X Tled-36 W P3242 Or Equiavlent Approved Make With Leds: Supply And Fixing Of Wall Mounted / Suspended Type Weather Proof Light 2Xtled-Tmc501-2X Tled Or Equiavlent Approved Make With Leds, 36 W Or More. Led Fitting Of Phillips Or Equivalent Approved Make Complete With All Accessories Such As Led Module, Driver, Optics, Thermal Sink, Connector Blocks Etc Including Installation With Led Of Approved Make. 355 Wt550c Led35scwpsu S1 Pc: Supply And Fixing Of Surface Mounted Weather Proof Light Wt550c Led35scwpsu S1 Pc Led 42 W Having 3500 Lumens Output Fitting Of Phillips Or Equivalent Approved Make Complete With All Accessories Such As Led Module, Driver, Optics, Thermal Sink, Connector Blocks, Etc. Including Installation. 356 Dn170c Led10s-6500 Psu Wh: Supply And Fixing Of Surface Mounted Weather Proof Light Dn170c Led 15 W Having 1000 Lumens Output Fitting Of Phillips Or Equivalent Approved Make Complete With All Accessories Such As Led Module, Driver, Optics, Thermal Sink, Connector Blocks Etc Including Installation. 357 Critical Light: Non Flame Proof Type Pel 240 M / Sl Of Prolite Or Of Approved Make As Per Eic, With 2 X 18 W Led Tl / Lamp Including Sealed Lead Acid Battery Of Suitable Size For Minimum 01 Hour Back Up, Battery Charger, For Fire Fighting Pump Shed, Ht / Lt Room, Battery Room Etc.The Job Includes Connection Of The Fitting, 6A Switch Socket With 2C X 4 Sqmm Cable From Db / Switch Board And As Mentioned Above Including All Accessories Etc. Complete In All Respect As Per Direction Of Eic / Site Engineer. 358 All In One Solar Based Led Street Light: 359 Installation, Testing, Commissioning Charges Of All In One Solar Based Led Street Light Including Supply Of 5 M High Gi Pole ( With Suitable Panel Mounting Arrangement ) And Associated Civil Foundation Works Complete In All Respects. 360 Supplying And Laying Reinforced Cement Concrete Light Duty Hume Pipe, Non Pressure Type ( Np3 ) , Centrifugally Cast Conforming To I.S.458 With 1:3:6 Concrete Casing At Joints As Required With Necessary Slope Including Excavation, Backfilling, Supply Of Collars, Jointing Of Pipes With Stiff Mixture Of Cement Mortar In The Proportion Of 1:2 ( 1 Cement: 2 Fine Sand ) , Testing Of Joints, Complete In All Respects As Per Direction Of The Eic / Site Engineer: 361 300 Mm Dia 362 200 Mm Dia 363 Sand Filling 364 Supplying And Spreading Of Approved Quality Fine Dry River Sand In Cable Trenches Including The Cost Of All Material, Transport, Load And Lift Charges, Labour, Tools And Tackles, Consumables Etc , As Per Directions Of Site Engineer / Engineer-In-Charge 365 Supply Fixing And Erection Of Modular Cable Transit ( Mct ) For Cable Entry To Building In Proper Frame Including Supply Of Peelable Type, Spare Block, Stay Plates Compression Wedgs Etc. With All Accessories Considering 20 % Minimum Spare In Each Module To Be Installed As Per Instruction Of Engineer In Charge / Site Engineer: 366 Galvanised Mild Steel Frame With Packing Space Of Min.120X240 Mm With Multi Diameter Blocks And Accessories With Peeling Off Arrangement To Adjust Cable Size From 3.5Mm To 99Mm Outer Dia 367 Galvanised Mild Steel Frame With Packing Space Of Min.120X180 Mm With Multi Diameter Blocks And Accessories With Peeling Off Arrangement To Adjust Cable Size From 3.5Mm To 99Mm Outer Dia 368 Brick Soling 369 Supply And Laying Of Approved Quality 75 Mm. Thick Second Class Brick Flat Soling With Sand Filling In The Interestices, In Cable Trenches For Protection Of Laid Cables In All Respects Including Consumables, Tools / Equipments And Labour As Per Directions Of Engieer-In-Charge / Site Engineer. 370 Outgoing Mccb Feeder As Per Instructions Of Engineer In Charge 371 Feeder Rating 32A 372 Outgoing Sfu Feeder As Per Instructions Of Engineer In Charge 373 Feeder Rating 32 / 32A 374 Flood Light Luminaires With Separate C.G. Box Including Cost Of Lighting Fixtures: Supply, Installation, Connection And Testing Of Following Flood Light Luminaries Of Philips / Approved Equivalent Make With Suitable Lamps ( Lamps Cost Will Be Paid Separately ) And Seperate Control Gear Box ( Cg Box Cost Will Be Paid Separately ) On Flood Light Mast, Supply And Fixing Of Clamps, Supports, Nuts, Bolts Including Welding, Painting Etc. All Complete With Labour And Materials As Per Directions Of Engineer-In- Charge. 375 Type Qvf 135 / 500 W Halogen Halolite Floodlight Luminaire 376 Type Qvf 135 / 70 W Mhn-Td Halolite Floodlight Luminaire Including Separate Cg Box 377 Control Gear Box For Flood Lighting Including Cost Of C.G. Box: Supply, Installation, Connection, Testing And Commissioning Of Control Gear Box Of Philips / Approved Equivalent Make Suitable For Flood Light Mast Fittings Including Supply Of Steel Structures / Flat / Angles And Welding, Painting Etc. All Complete With Labour And Materials As Per Directions Of The Engineer-In-Charge. 378 Zvx X 300 / 250 / 240, 1X250 W Hpi-T Pressure Die Cast Aluminium Cg Boxrs With Open Construction Ballasts 379 Zvx X 310 / 400 / 240, 1X400 W Hpi-T Pressure Die Cast Aluminium Cg Boxrs With Open Construction Ballasts 380 Zvx 330 / 250 / 240, 1X250 W Son Pressure Die Cast Aluminium Cg Boxes With Open Construction Ballasts 381 Zvx X 410 / 1000 / 220, 1X1000 W Hpi-T Die Cast Aluminium Cg Box 382 Zvx X 260 / 70I / 240, 1 X 70 W Mhn-Td Pressure Die Cast Aluminium Cg Boxes With Open Construction Ballasts 383 Zvx X 340 / 250 / 240, 1X400 W Son Pressure Die Cast Aluminium Cg Boxes With Open Construction Ballasts 384 Supply And Inst. Of C.G. Box For Flame Proof Fittings : Supply, Installation, Connecting, Testing And Commisioning Below Given Flameproof Cg Box, Approved For Zone-1 And Gas Group Iia, Iib Including Supply Of Necessary Mounting Steel Structure / Flat / Angle And Welding, Painting Etc. All Complete With Labour And Materials As Per Directions Of Eic. 385 Type Flpw 927 ( Baliga ) / Type Cgf-1108 ( Crompton ) / 80 W Hpmv Flameproof Cg Box Approved For Zone-I To Gas Group Iia, Iib 386 Supply And Inst. Of Increased Safety Control Gear Box : Supply, Installation, Connecting, Testing And Commisioning Below Given Increase Safety Cg Box, Approved For Division 2 And Gas Group Iia, Iib & Iic Including Supply Of Necessary Mounting Steel Structure / Flat / Angle And Welding, Painting Etc. All Complete With Labour And Materials As Per Directions Of Eic. 387 Type Is 30660 ( Baliga ) / Type Cgi 1108M ( Crompton ) / 80 W Hpmv Increased Safety Cg Box Approved For Division_2 And Gas Group Iia, Iib, Iic 388 Supply Of Lamps : Supply Of Below Given M / S Philips Or Equivalent Make Lamps For Installation In Lighting Fittings / Fixtures As Per Directions Of Eic. 389 Led Bulb 5-6W 390 Led Bulb 9W 391 Led Tubelight 18W 392 Installation Of Lighting Fixtures ( Excluding Cost Of Fixtures ) : Fixing Of Following Light Fittings Attachments On Ms Hanger / Supports / Concrete Wall Structure / Steel Structure Completed With Lead In Wires And Other Accessories All Complete With Labour And Materials As Per Direction Of The Engineer-In-Charge. ( Cost Of Light Fittings / Lamp Control Gears And Other Fittings Shall Be Excluded ) . 393 Flp / Increased Safety Wellglass / Bulkhead / Tubelight / Floodlight 394 Flp / Increased Safety Control Gear Box / Junction Box / Switch / Socket 395 Recessed Tubelight Fitting 396 Ordinary Bulkhead / Pl Type Fitting 397 Street Light Fitting ( Upto 9 M Height ) 398 Street Light Fitting ( More Than 9 M Height ) 399 Floodlight Without Control Gear 400 Control Box For Floodlight 401 Floodlight Without Control Gear ( More Than 9 M Height Including On Fldm ) 402 Control Box For Floodlight ( More Than 9 M Height Including On Fldm ) 403 Overhauling Of Window Ac, Split Ac, Water Cooler Etc. 404 Overhauling And Painting Of Wac, Sac, Wc & Cold Storage Of Different Make & Different Capacities Located At Various Location Within The Iocl Premises. Job Includes Removal Of Machines From Location , Dismantling , Cleaning , Washing , Chemical Cleaning Of Condenser & Cooling Coil , Overhauling , Lubrication Of Blower Motor , Checking , Repair / Rectification / Replacement Of Effective Control Component. Painting Of All Metal Part And Chassis Cover Internal Painting With Primer & Outer Painting With Synthetic Enamel Paint. Cleaning Of Coil & Condenser To Be Done With Wire Brush. Defective / Damage Insulation To Be Replaced. All The Electrical Wires Must Be Dressed Properly. Defective Wires To Be Replaced Including Supply Of Wires. Defective / Damage Asbestos Sheet To Be Replaced. Asbestos Sheet Shall Be Provided By The Owner. Cleaning / Replacement Of Filter By Nylon Filter.Reassembly Of Machine, Shifting To Location & Testing Of Machine. Job Complete In All Respect Including Men & Material And As Per Direction And Instruction Of Site Engineer / Engineer-In-Charge. 405 Monthly Routine Maintenance Of Window Ac, Split Ac, Water Coolers Etc. 406 Routine, Regular And Breakdown Maintenance Of Wac, Sac, Wc And Cold Storage Of Different Make & Different Capacities Installed At Various Location Of Iocl Premises . Job Includes Attending The Complaints Of Machines As Per The Complaint Register And Instruction Of Site Engineer. Job Includes Checking Of Machines, Identification Of Defect, Repair / Replacement Of Defective Component. Rewinding Of Blower Motor. Replacement Of Thermostat, Blower, Fan Blade, Electrical Switches, Control Knob, Wires. Cleaning Of Air Filter, Removal Of Dust From Cooling Coil & Condenser By Removing The Machine From Location If Required. Attending The Minor / Major Leakage Of Refrigerant Gas R-22 / R-12 Arresting The Leak And Recharging The Gas. Repair / Replacement Of Defective Bush / Bearing Of Blower Motor Including Lubrication Of Blower Motor, Tightening Of All The Electrical Connection. Repair / Replacement ( By Repaired Compressor ) Of Defective Compressor. Job Includes Dismantling Of Defective Compressor Either At Site Or At Workshop After Transportation Of Machine To Workshop, Taking Necessary Gate Pass / Permission From Concerned 407 Installation Of Split Ac 408 Transportation, Installation, Testing & Commission Of 2.0 / 3.0 Tr Split Ac Of Any Indian Make. Job Includes Supply And Providing Copper Tube Upto 4.0 Meter, Insulation Of Copper Tube, Refrigerant Gas R-22 Charging, Supply & Fixing Required Electrical Wire. Job Complete In All Respect As Per Direction Of Site Engineer / Engineer-In- Charge. 409 Additional Copper Tube For Split Ac 410 Supply & Fixing Of Additional Length Of Copper Tube For Split A / C Commissioning Including All Accessories. 411 Replacement Of Burnt Uncut Compressor 412 Replacement Of Burnt Uncut Compressor Of 1.5-Ton Capacity From The Manufacturer Whenever Required As Per Direction Of Engineer-In-Charge. 413 Replacement Of Burnt Uncut Compressor Of 1.0 Ton Capacity From The Manufacturer Whenever Required As Per Direction Of Engineer-In-Charge. 414 Gas Charging Of Air Conditioner 415 Gas Charging Of Air Conditioner Upto 1.5 Ton Capacity With Job Involved Transportation Of Machine To Vendors Works. Checking Of All Components For Leak By Charging Co2 Gas & Finally Evacuating The Compressor Completely & Charges Of Refrigerant Gas - 22. A 416 Electrical Service Items 417 Cable Laying - Laying Of All Type Of Cables Lt ( Pvc / Xlpe / Armoured / Unarmoured / Power / Control / Signalling ) In Trenches, In Cable Racks, In Trays, In Protective Pipes, Poles, Columns, In Conduits, In Panels And On Structures Etc.; Including The Supply And Installation Of All Required Materials Such As Fixing Clamps, Screws, Cable Straps, Tags, Etc. As Required ( Other Than The Supply Of The Conduits, Cables, Pipes, Cable Racks, Trays, Poles, Structures And Panels ) Complete In All Respect, Including Cost Of All Labour, Tools, Consumable Materials, Etc. And Cutting The Cables In Required Lengths As Per Directions Of Site Engineer / Engineer-In-Charge: 418 Power Cables Lt : Od Upto 20 Mm 419 Power Cables Lt : Od Above 20 Mm And Upto 40 Mm 420 Power Cables Lt : Od Above 40 Mm And Upto 60 Mm 421 Power Cables Lt : Od Above 60 Mm 422 Power Control Cables Lt : Od Upto 20 Mm 423 Cable Laying - Laying Of All Type Of Cables Lt ( Pvc / Xlpe / Armoured / Unarmoured / Power / Control / Signalling ) In Trenches, In Cable Racks, In Trays, In Protective Pipes, Poles, Columns, In Conduits, In Panels And On Structures Etc.; Including The Supply And Installation Of All Required Materials Such As Fixing Clamps, Screws, Cable Straps, Tags, Etc. As Required ( Other Than The Supply Of The Conduits, Cables, Pipes, Cable Racks, Trays, Poles, Structures And Panels ) Complete In All Respect, Including Cost Of All Labour, Tools, Consumable Materials, Etc. And Cutting The Cables In Required Lengths As Per Directions Of Site Engineer / Engineer-In-Charge: 424 Power Cables Ht 425 Removal Of Rubbish / Debris / Brickbats 426 Removal Of Rubbish / Debris / Brickbats, Laterite Boulders, Earth, Plaster Flakes Etc. Including Carriage By Mechanical Transport Including Packing Stacking The Rubbish In Regular Stacks At Loading Points At Different Places Before Loading The Same In The Trucks And Unloading The Same At Directed Places Upto A Lead Of 2 Km, Including Local Carriage Of Rubbish At Loading And Unloading Point Etc. Complete As Per Direction Of The Engineer-In-Charge. ( Payment Will Be Made By Stack Measurement After Deducting 20% For Voids From Stack Measurement ) . 427 Painting Of Electrical Equipments 428 Cleaning Of Surface, Rust Removing Of Foreign Matter, Rubbing Down Thoroughly With Emery Paper, Wire Brush, Washing With Degreasing Solvent ( White Spirit ) To Remove Grease Etc. And Preparation Of Surface For Application Of Enamel Paint By Spray Painting On Bus Ducts, Transformers / Motors / Or Any Other Metallic Surface With One Coat Of Ready Mixed Primer And Two Coats Of Approved Quality / Apcolite Asian Synthetic Enamel Paint Including Supply Of Paint Suitable For A Temperature Of 100 Degree Celsius. All Complete With Labour And Materials As Per Directions Of The Engineer-Incharge. 429 Cleaning Of Surface, Rust Removing Of Foreign Matter, Rubbing Down Thoroughly With Emery Paper, Wire Brush, Washing With Degreasing Solvent ( White Spirit ) To Remove Grease Etc. And Preparation Of Surface For Application Of Paint By Spray Painting On Electrical Equipment / Structures / Poles Or Any Other Metallic Surface With Two Coats Of Approved Brand & Manufacturer Of Aluminium Paint Including Supply Of Paint Suitable For A Temperature Of 100 Degree Celsius. All Complete With Labour And Materials As Per Directions Of The Engineer-In-Charge. 430 Lettering 431 Lettering With Black Japan Paint Of Approved Brand And Manufacture Note : Unit Of Measurement Is Considered Each Which Is Equal To Per Cm Height Per Letter. 432 Ht Cable Disconnection: Disconnection Of Ht Cables Of Following Sizes At One End And Reconnecting It At Same Place Or Another Place After Dressing And Cleaning The Terminals All Complete With Labour And Materials As Per The Direction Of The The Engineer-Incharge 433 Overall Diameter Upto 35 Mm 434 Overall Diameter > 35 Mm But Upto 55 Mm 435 Overall Diameter >55 Mm But Upto 75 Mm 436 Overall Diameter > 75 Mm 437 Lt Cable Disconnection: Disconnection Of Lt Cables Of Following Sizes At One End And Reconnecting It At Same Place Or Another Place After Dressing And Cleaning The Terminals All Complete With Labour And Materials As Per The Direction Of The The Engineer-In-Charge. 438 Overall Diameter Upto 35 Mm 439 Overall Diameter > 35 Mm But Upto 55 Mm 440 Overall Diameter >55 Mm But Upto 75 Mm 441 Overall Diameter > 75 Mm 442 Temporary Laying And Dismantling Of Cables: Temporary Laying And Dismantling Of Following Cables ( Armoured / Unarmoured, Power / Control / Telecommunication / Computer ) Of Different Voltage Grades / Sizes / Types For Temoprary Connections During Shutdown Etc., Including Transportation Of Cable From Stores / Another Site And Returning The Same After Dismantling To Store, All Complete With Labour And Materials As Per Directions Of The Engineer-Incharge. 443 Overall Diameter Upto 35 Mm 444 Overall Diameter > 35 Mm But Upto 55 Mm 445 Overall Diameter >55 Mm But Upto 75 Mm 446 Overall Diameter > 75 Mm 447 Cleaning Of Light Fitting Fixtures: Cleaning Of Below Given Fitting Fixtures Alongwith Perfex Cover ( Wherever Applicable ) With The Help Of Surf Powder. It Includes The Removal Of Perfex Cover, Washing The Lighting Fixture With Powder, Cleaning With Fresh Water And Clothes And Refixing In The Same Position. It Also Includes Arranging Ladder As And Wherever Required, Providing Scaffolding At All Heights With Necessary Tools & Tackles. All Complete With Labour And Materials As Per Directions Of The Engineer-Incharge. 448 Tube Light Fitting / Ceiling / Exhaust Fan / Fan At Any Height Inside A Building. 449 Mll / Hpmv / Hpsv Lamp Of Flp / Increased Safety / Weather Proof Or Any Other Similar Fittings Upto 250 W 450 Lt Panel Cleaning 451 Cleaning Of Complete Pcc / Mcc Panels. It Includes Opening Of Side Top Covers, Removal Of Dust By Vacuum Cleaners / Blowers Etc., Checking And Tightening Of Screws, Nuts, Bolts, Washers & Connections, Application Of Petroleum Jelly And Boxing Up Of The Panels. All Complete With Labour And Materials As Per Directions Of The Engineer-In-Charge. 452 Earth Resistance Measurement 453 Measurement Of Earthing Resistance In Thepump Station / Rcp / Cp / ( Other Pipeline Installation ) Including Transportation Of Earthing Electrodes, Cables Etc. From Stores To Site, Drawing The Same Into The Ground At Different Points For Measuring The Earth Resistance. The Job Includes The Supply Of Connecting Leads, Clamps Etc. All Complete With Labour And Materials As Per Directions Of The Engineer-In-Charge. Note Measuring Instruments To Be Supplied By The Owner 454 Transformer Cleaning 455 Cleaning Of Transformer Includes Surface Cleaning I.E. Cleaning Of Accumulated Sticky Oil And Other Dust, Oil Fins. Job Includes Opening Of Lt Duct & Ht Terminal Box, Cleaning Of Duct And Terminal Box, Tightening Of Nuts & Bolts Wherever Is Required. Job To Be Completed With All Men, Materials And Equipments Like Tools & Tackles As Per Direction And Satisfaction Of The Engineer-In-Charge. All Cleaning Materials Such As Markin Cloth, Cotton Waste Etc. Shall Be Supplied By The Contractor. 456 Ht / Lt Motor Cleaning: Cleaning Of Ht / Lt Motors & Its Push Button Includes Cleaning Of Accumulated Oil / Spilage Oil & Other Particles On The Surface Of Motor & Connected Cable & Surrounding Area Of The Motor. All Cleaning Material Such As Cotton Waste, Markin Cloth Etc. Shall Be Supplied By The Contractor. Job To Be Completed With All Man & Material As Per Direction & Entire Satisfaction Of The Engineer-In- Charge. 457 Ht Motors 458 Lt Motors Less Than 45 Kw 459 Lt Motors 45 Kw & Above 460 Fixing Of Electrical Components 461 Fixing, Fitting, Commissioning, Assembly Of Loose Supplied Components, If Any, And Connecting Of One No. Switch Fuse Unit / Automate / Starter Of Rating Upto 400 A , 3 Phase, 415 V With On Without Relay In Normal / Explosion Proof Enclosure, Existing / New Distribution Panel Or In Control Panel, Mounted On Wall / Floor Etc. Transportation Of Automate / Starter / Switch Fuse Unit From The Store To The Site ( Maximum Distance Of 10 Km ) . Job Complete In All Respect With Labour And As Per Thedirection Of Engineer-In-Charge Excluding Supply Of Switch Fuse Unit / Automate / Starter. 462 Cable Trench: 463 Excavation In Unpaved Ares Of Earth In The Work Sites For Cables Trenches For A Depth Upto 1.5 Meters Including Shoring, Strutting Etc. ( If Necessary ) , Backfilling The Trench After Cable Laying With Excavated Earth Or Sand Within The Work Sites Complete In All Respects Including Consumables, Tools / Equipments And Labour. The Work Shall Be Performed As Per Directions Of Engineer-In-Charge / Site Engineer. 464 Lightning Arrestor : Erection, Installation, Testing & Commissioning Of Lightning Arrestors With Insulating Base, Discharge Counter, Fittings Etc. Including Assembling As Required, Installation On Already Made Steel Structures Or Fixtures, Aligning, Levelling, Grouting, Assembling And Fitting Of Accessories / Instruments Etc. Supplied Separately, If Any, Making Of The Conductor Connection, Cables Connections As Required, Earthing, Testing, Commissioning The Same, Complete In All Respects Including Consumables, Tools / Equipments And Labour As Per Directions Of Engineer-In-Charge / Site Engineer. The Supply Of Earthing Strip Is Not Covered In This Item. 465 For 60 Kv Rated Voltage ( Highest System Voltage 72.5 Kv ) , 10 Ka Lightening Arrestors 466 For 30 Kv Rated Voltage ( Highest System Voltage 36 Kv ) , 10 Ka Lightening Arrestors 467 Brick Work In Cable Trench: Removal Of Bricks From Cable Trench Without Any Damage To The Cable And Disposing It Within A Lead Of 50 Meteres Or Stacking It At The Edge Of The Trench And Putting It Back Into The Same Trench Or In A New Cable Trench Within A Lead Of 50 Meteres After The Work Is Completed Including Completing The Work In Allrespects With All Labour And Materials As Per The Direction Of The Engineerin-Charge. 468 Removal And Relaying 469 Removal And Stacking Only 470 Removal Of Sand From Cable Trench 471 Removal Of Sand From Cable Trench Without Any Damage To The Cable And Disposing It Within A Lead Of 50 Meteres Or Putting It Back Into The Same Trench Or In A New Cable Trench Within A Lead Of 50 Meteres All Complete With Labour And Materials As Per The Direction Of The Engineer-Incharge. 472 Removal Of Rcc Slab Upto 150 Mm Thick 473 Removal Of Rcc Slab Upto 150 Mm Thick And Of Any Size Placed Above The Cable Trench, Handling Carefully Without Any Damage Of The Slab And Cable Beneath It And Keeping It Back In Position After Laying / Removing The Cable And Sealing The Same Between Rcc Covers With Cement & Sand. Job Complete In All Respect With Labours And Materials And As Per Direction Of Engineer -In-Charge. 474 Cable Dismantling / Pull Out: Dismantling / Pulling Out The Lt / Ht, Pvc / Xlpe, Power / Control / Telephone / Computer, Armoured / Unarmoured Cables Of Various Voltage Grades / Types / Sizes / Makes From The Trench ( Upto 1.5 Metres Deep ) / Pipes / Structures / Racks Or Trays, Rolling It Into Empty Cable Drums, Returning The Filled Up Cable Drums To The Store / Another Site Including Transportation Of Empty Cable Drums From Stores To Site And Filled Up Cable Drums From Site To Stores / Another Site, Etc. Including Cutting Of Cables At Joints / Termination, Dismantling Of Clamps Etc. All Complete With Labour And Materials As Per Directions Of The Engineer-Incharge. 475 Overall Diameter Upto 35 Mm 476 Overall Diameter > 35 Mm But Upto 55 Mm 477 Overall Diameter >55 Mm But Upto 75 Mm 478 Overall Diameter > 75 Mm 479 Cable Dismantling / Pull Out And Relaying: Dismantling / Pulling Out The Lt / Ht, Pvc / Xlpe, Power / Control / Telephone / Computer, Armoured / Unarmoured Cables Of Various Voltage Grades / Types / Sizes / Makes From The Trench ( Upto 1.5 Metres Deep ) / Pipes / Structures / Racks Or Trays And Relaying As Per Direction Of Engineerin-Charge, All Complete With Labour And Materials. Job Includes Declamping, Rerouting And Relaying Of Cable For Reglanding Etc. 480 Overall Diameter Upto 35 Mm 481 Overall Diameter > 35 Mm But Upto 55 Mm 482 Overall Diameter >55 Mm But Upto 75 Mm 483 Overall Diameter > 75 Mm 484 Dismantling Of Power Distribution Equipments: Dismantling Of Following Power Distribution Equipments Without Any Damage To It And Returning It To Our Stores Or Reinstallation Of Same At A Place Within A Lead Of 3 Km ( Reinstallation Charges Not Includes ) All Complete With Labour And Materials As Per The Direction Of The Eic. 485 Small Equipment Requiring Tractor Trailer But Not Requiring Crane / Hydra Etc. ( Beyond 100 Kg. ) 486 Equipment Weighing Above 500 Kg And Requiring Hydra And Tractor Trolley Etc. 487 Equipment Weighing More Than 3 Mt And Requiring Crane And Tractor Trolley Etc 488 Attending Complaints : Attending And Rectification Of Complaint Of The Following Note: All Materials & Accessories Of Fittings Required For Attending The Complaint Shall Be Supplied By The Owner Free Of Cost. The Contractor Has To Take The Material From Central Store / Departmental Store / Site In-Charge. For Attending Above Complaints. The Defective Material Are To Be Returned To The Deptt. Stores. Consumables Items Like Pvc Tape, Cleaning Tape, Cleaning Cloth, Ctc Etc. Are In The Scope Of Contractor. Also Application Of Pvc / M-Seal On Above Fittings To Above Entering Of Water / Insects As Per Direction Of The Engineer-In_Charge. 489 Tube Light Fittings Including Replacement Of Chokes, Tubes, Down Rods, Starters, Starter Holder, Tube Rod And Holders And All Other Accessories If Needed Including Cleaning Of The Light Fittings If Required. All Complete With Labour And Materials As Per Direction Of The Engineer-In-Charge 490 Flp / Increased Safety And Weatherproof Upto 250 W Lamps Including Replacement Of Lamps, Lamp Holders, Connectors, Glass & Other Accessories Etc. Including External And Internal Cleaning Of Glass And Complete Fittings As Well As Other Related Job Involved. All Complete With Labour And Materials As Per Directions Of Engineer- In- Charge. 491 Control Gear Boxes Of Hpmv Lamp Fittings Upto 250W Including Replacement Of Chokes, Condensers, Fuses, Holders, Fuse Base, Wiring Or Any Other Accessories Of Control Gear Box. All Complete With Labour And Materials As Per Directions Of The Engineer-In-Charge. 492 Fldms / Highway Fittings / Street Light Fittings Including Replacement Of Lamps, Tubes, Ignitors, Chokes, Capacitors, Fuses, Fuse Holders, Gasket, Providing / Extension Rod On Lamp Holder Glass Including Cleaning Of Glass Or Any Other Accessories Required. All Complete With Labour And Materials As Per Directions Of The Engineer-In-Charge. 493 Circuit Fault Rectification 494 Rectification Of Circuit Fault In Flp / Non Flp Junction Boxes / Djbs / Dbs / Switchboards Etc. Other Than In Fldms Including Supply Of Minor Type Of Materials Costing Less Than Rs.6.00 In One Complaint. All Complete With Labour And Materials As Per Directions Of The Engineer-In-Charge. Note : Materials Used By Contractor Should Not Exceed Rs.6.00 Per Complaint. Balance Material Exceeding Rs. 6.00 Per Complaint Shall Be Supplied By Owner Free Of Cost. Also Application Of Pvc Putty / M-Seal Putty On Above Fittings, If Required, To Avoid Entering Of Water / Insects As Per Directions Of The Engineer-In Charge. Putty Will Be Supplied By Owner Free Of Cost. 495 Miscellaneous Complaints 496 Attending Complaint Of Installation E.G. Hand Lamps, Flood Lights, Exhaust Fans, Halogen Fittings, Smoking Booth & Other Elect. Complaints & Replacement Of Crocodile Clips On Earthing Leads With A Maximum Period Of One Hour From The Time Of Receipt Of Complaint. 497 Cleaning Of Cable Trenches 498 Cleaning Of Cable Trenches Of Depth Upto 3 Meter And Width 1.5 Meter Of Cable Galleries, Sub Stations And Other Locations Etc. The Job Includes Lifting Of Rcc Slabs / Chequerred Plates, Removing Of Paper Waste Jute, Mud, Or Any Other Unwanted Materials Lying In Trenches & Dumping These Waste Materials In The Nearest Dust Bin Or As Directed By The Engineer-In-Charge., Keeping Back Rcc Slabs / Chequerred Plates In Positions. All Complete With Men And Materials As Per Direction Of The Engineer-In Charge. 499 Horizontal Drilling 500 Making Horizontal Bore / Drill For Roads At Different Location. Job Includes Pipe Coupling & Cutting, Insert The Pipe Through Both Side Of The Road And Make It As Original ( Gi Pipe, Ms Pipe From 2 To 8 Meter Long ) ( Horizontal Drilling ) . Gi / Ms Pipe Supply Shall Be In The Scope Of Iocl. Transportation Of The Pipe From Stores / Site To Work Site Shall Be In The Scope Of The Contractor. 501 Replacement Of Old Transformer Oil 502 Replacement Of The Old Oil From The Transformer As Per The Specifications Given Below A ) Old Oil Heating By Hot Oil Circulator For 4 Hrs. B ) Draining Out Entire Quantity Of Oil. C ) Blanking Of All Opening For Vaccum Pulling. D ) Applying Vacuum Pulling For 4 Hrs Minimum 600 Hg Mercury Pressure. E ) Filtration Of New Transformer Oil For Filling. F ) Filling The Oil Under Vacuum & Filtration Of Oil Till Desired Bdv Is Attained As Per Is. G ) Releasing All The Air From Air Release Plug & Bucholz Relay H ) Topping Up Of Oil. I ) To And Fro Transportation Of Filter Machine And Equipments. J ) Transportation Of Old And New Oil. 503 Wbm Road / Concrete Breaking: 504 Wbm Road / Concrete Breaking For Cable Trenches Including Required Shoring Strutting Etc., And Repairing Of The Road / Dyke To Original Condition And Disposing Off Excess Materials ( Within The Work Site ) Job Complete In All Respects Including The Cost Of Labour, Tools, Materials, Load, Lift Hire Charges Of Equipments, If Any, Complete As Per Directions Of Site Engineer / Engineer-In-Charge. 505 Excavation In Hard Rock : 506 Excavations In Hard Rock Requiring Chiselling For Cable Trenches Upto Depth Of 1.5 Metres, Including Shoring, Strutting ( If Necessary ) , Excavated Earth Or Sand To Be Back Filled ( After Cable Laying ) To The Finished Level And Excess Earth To Be Disposed Off Within The Work Sites Complete In All Respects Including Comsumables, Tools / Equipments And Labour. The Work Shall Be Performed As Per Directions Of Engineer-In-Charge / Site Engineer. 507 Itc Of Ceiling Fan And Regulator With Aluminium Connecting Cable 508 Installation, Testing And Commissioning Of Ceiling Fan And Regulator Including Wiring The Down Rod Of Standard Length ( Upto 30 Cm ) With 1.5 Sqmm, Pvc Insulated, Aluminium Conductor, Single Core Cable Etc. As Required. 509 Installation Of Exhaust Fan:Fixing Of Exhaust Fans On Existing Opening, Complete With Lead In Wires And Other Accessories All Complete With Labour And Materials As Per Direction Of The Engineer-In Charge. ( Cost Of Fans Shall Be Excluded ) 510 With Louver Shutter / Mesh 511 Without Louver Shutter / Mesh 512 Flp / Is Exhaust Fan 513 Dismantling Of Split Ac 514 Dismantling , Shifting Of 2.0 / 3.0 Tr Split Ac Including Dismantling Of All The Copper Tube, Condensing Unit, Electrical Connection To New Location Or A / C Workshop As Per Direction Of Site Engineer / Engineer-In-Charge. 515 Electrical Supply Items 516 Shock Treatment Chart 517 Supply Of Shock Treatment Chart In Glass Frame Suitable For Wall Mounting 518 Safety Equipment - Supplying The Following Safety Equipment As Per Directions Of Site Engineer / Engineer-In-Charge Complete In All Respects Including Transportation Charges: 519 Supply And Installation Of 33 Kv Discharge Rod 520 Supply Of Hand Gloves 521 Suitable For 11 / 33 Kv Voltage Level With Isi Mark And With Test Certificate With Issue Date Within 1 Month 522 Supply Of Elastomer Mat 523 Supply Of 2000Mm X1000 Mm, 3 Mm Thick ( Class B ) Elastomer Mats Conforming To Is: 15652:2006 524 Insulating Elastomer Mats Conforming To Is 15652:2006 Of Thickness 2.5 Mm ( Class B ) 525 Extra For Providing Copper Lugs: Supply ( To Be Used Only When It Is Mentioned In Sor That Lug Supply Is Excluded ) Of Copper Tube Terminal Heavy Duty ( Crimping Cable Lug ) Of Kse / Dowells Make Or Equivalent Certified By Eic. Of The Following Sizes. 526 1.5 Sqm 527 2.5 Sqm 528 4.0 Sqm 529 6.0 Sqm 530 10.0 Sqm 531 16.0 Sqm 532 25 Sqmm 533 Extra For Providing Aluminium Lugs: Supply ( To Be Used Only When It Is Mentioned In Sor That Lug Supply Is Excluded ) Of Aluminium Tube Terminal Heavy Duty ( Crimping Cable Lug ) Of Kse / Dowells Make Or Equivalent Certified By Eic. Of The Following Sizes. 534 16.0 Sqm 535 25 Sqmm 536 35 Sqm 537 50 Sqm 538 70 Sqm 539 120 Sqm 540 150 Sqmm 541 240 Sqmm 542 300 Sqmm 543 Extra For Providing Flameproof Double Compression ( Brass ) Cable Glands: Supply ( To Be Used Only When It Is Mentioned In Sor That Gland Supply Is Excluded ) Of Cmrs / Cce Approved Flameproof Double Compression ( Brass ) Cable Gland For Following Overall Cable Sizes As Per Directions Of Engineer-In-Charge. 544 10.0 To 16.0 Mm 545 16.5 To 18.0 Mm 546 18.5 To 20.0 Mm 547 20.5 To 23.0 Mm 548 23.5 To 26.0 Mm 549 26.5 To 30.0 Mm 550 30.5 To 33.0 Mm 551 33.5 To 37.0 Mm 552 37.5 To 41.0 Mm 553 41.5 To 46.0 Mm 554 46.5 To 52.0 Mm 555 52.5 To 60.0 Mm 556 60.5 To 66.0 Mm 557 Lightning Arrestor : Supply Of Lightning Arrestors With Insulating Base Fittings Etc. As Per Specifications 558 For 60 Kv Rated Voltage ( Highest System Voltage 72.5 Kv ) , 10 Ka Lightening Arrestors 559 For 30 Kv Rated Voltage ( Highest System Voltage 36 Kv ) , 10 Ka Lightening Arrestors 560 Supply Of Materials / Equipments As Given Below Complete In All Respects, As Per The Instruction Of Eic Including Transportation To Site And Storing : 561 Supply Of Zn Grounding Cells ( With Prepackaged Backfill Material ) Including Required Length Of Cable ( Minimum 10 M ) Of Approved Make & As Per Instructions Of Eic. 562 Dcdb 563 Installation And Commissioning Of Wall Mounted Dcdb Including Supply Of All Cable End Lugs, Cable Glands, Fittings & Fixtures And All Other Required Accessories, Tools And Tackles Complete In All Respects As Per Directions Of Site Engineer / Engineer-In-Charge. Item Includes Supply And Termination Of 2 Runs Of 1Cx25 Sq. Mm Copper Cable For Battery Bank 564 Ht 33 Kv, 11 Kv & 6.6 Kv Cables - Screened, Xlpe Insulated, Extruded Pvc Type St-2 Inner Sheathed, Galvaznized Armoured, Pvc Type St-2 Overall Sheathed, Stranded, Frlsh, C2, Smoke Density<40% 565 Al 3Cx120 Mm² 6.6Kv 566 Al 3C X 150 Mm² 6.6 Kv 567 Al 3Cx185 Mm² 6.6Kv 568 Al 3Cx240 Mm² 6.6 Kv 569 Al 3Cx400 Mm² 6.6Kv 570 Al 3Cx400 Mm² 33Kv 571 Lt Cables Frlsh - Aluminium Cables-1.1 Kv, Xlpe Insulated, Extruded Pvc Type St-2 Inner Sheathed, Galvanized Armoured, Pvc Type St-2 Overall Sheathed, Stranded, Frlsh, C2, Smoke Density<40% 572 Al, 3Cx10 Mm², A2xfy 573 Al, 3Cx16 Mm² 574 Al, 4Cx16 Mm², A2xfy 575 Al, 3Cx25 Mm², A2xfy 576 Al, 3.5Cx25 Mm², A2xfy 577 Al, 4Cx25 Mm², A2xfy 578 Al 3C X 35 Mm² 579 Al, 3.5Cx35mm², A2xfy 580 Al, 3Cx50mm² 581 Al, 3.5Cx50 Mm², A2xfy 582 Al, 3½C X 95 Mm² 583 Al, 3½C X 120 Mm² 584 Al, 3.5Cx150 Mm², A2xfy 585 Al, 3C X 185 Mm² 586 Al, 3½C X 185 Mm² 587 Al, 3.5Cx240 Mm², A2xfy 588 Al, 3.5Cx400 Mm², A2xfy 589 Supply Of Xlpe Insulated , Pvc Sheathed Cable, 1100 V Grade Conforming To Is: 7098 ( P-1 ) As Per Specifications And Approved Make 590 Copper Cable Size 1Cx50 Sq. Mm Armoured 591 Copper Cable Size 1Cx35 Sq. Mm Armoured 592 Copper Cable Size 1Cx25 Sq.Mm Armoured 593 Copper Cable Size 2Cx6 Sq.Mm Armoured 594 Copper Cable Size 2Cx25 Sq.Mm Armoured 595 Copper Cable Size 2Cx70 Sq.Mm Armoured 596 Tinned Copper Cable Size 1Cx10 Sq.Mm Unarmoured For Distributed Anodes Of Station Cp System 597 Civil Items 598 Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level : 1:2:4 [ 1 Cement : 2 Coarse Sand Derived From Natural Sources : 4 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ] 599 Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level :Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More 600 Brick Work With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 In Foundation And Plinth In : Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) 601 Random Rubble Masonry With Hard Stone In Superstructure Above Plinth Level And Upto Floor Five Level, Including Leveling Up With Cement Concrete 1:6:12 ( 1 Cement : 6 Coarse Sand : 12 Graded Stone Aggregate 20 Mm Nominal Size ) At Window Sills, Ceiling Level And The Like. 602 12Mm Plaster ( In Coarse Sand ) :1:4 ( 1 Cement : 4 Coarse Sand ) 603 Casting, Supplying And Erecting In Position Precast Reinforced Cement Concrete Elements ( With Proper Lifting Lugs ) For Trench & Drain Covers, Shelves, Partitions, Post, Slabs Etc. For All Leads And Levels Including Making Necessary Moulds, Vibrating, Tamping, Curing, Finishing The Top Surface With Cement Mortar 1:3 ( 1 Cement : 3 Fine Sand ) To Give A Smooth And Even Surface, Transportation To Site, Aligning And Fixing In Position With Cement Mortar 1:3 ( 1 Cement: 3 Find Sand, ) Including Making Recess In Brick Wall For Placing The Precast Element In Position And Making Good The Same Etc. Complete In All Respects Inclusive Of Cost Of All Labour, Materials, Tools, Tackles Etc. As Per Directions Of The Engineer-In-Charge. [ Note: Payment For Reinforcement Shall Be Made As Per Relevant Item Of Sor. ] :With Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 10 Mm Nominal Size ) . 604 Motor Items 605 Rewinding Of Lt Motor Upto & Incl 11 Kw As Per Special Conditions Of Contract ( Technical ) Of Tender Document 606 Rewinding Of Lt Motor 12-18 Kw As Per Special Conditions Of Contract ( Technical ) Of Tender Document 607 Rewinding Of Lt Motor 132-150 Kw As Per Special Conditions Of Contract ( Technical ) Of Tender Document 608 Overhauling Of Lt Motor Upto & Incl 11 Kw As Per Special Conditions Of Contract ( Technical ) Of Tender Document 609 Overhauling Of Lt Motor 12-15 Kw As Per Special Conditions Of Contract ( Technical ) Of Tender Document 610 Overhauling Of Lt Motor 132-260 Kw As Per Special Conditions Of Contract ( Technical ) Of Tender Document 611 Shaft Metallizing / Repair Of Lt Motor Upto & Incl 11 Kw As Per Special Conditions Of Contract ( Technical ) Of Tender Document 612 Shaft Metallizing / Repair Of Lt Motor 12-15 Kw As Per Special Conditions Of Contract ( Technical ) Of Tender Document 613 Shaft Metallizing / Repair Of Lt Motor 16-21 Kw As Per Special Conditions Of Contract ( Technical ) Of Tender Document 614 Shaft Metallizing / Repair Of Lt Motor 111-150 Kw As Per Special Conditions Of Contract ( Technical ) Of Tender Document 615 Dynamic Balancing Of Lt Motor Upto & Incl 11 Kw As Per Special Conditions Of Contract ( Technical ) Of Tender Document 616 Dynamic Balancing Of Lt Motor 12-15 Kw As Per Special Conditions Of Contract ( Technical ) Of Tender Document 617 Dynamic Balancing Of Lt Motor 111-150 Kw As Per Special Conditions Of Contract ( Technical ) Of Tender Document 618 Supply Terminal Plate Of Lt Motor Upto & Incl 11 Kw As Per Special Conditions Of Contract ( Technical ) Of Tender Document 619 Supply Terminal Plate Of Lt Motor 12-18 Kw As Per Special Conditions Of Contract ( Technical ) Of Tender Document 620 Supply Terminal Plate Of Lt Motor 111-150 Kw As Per Special Conditions Of Contract ( Technical ) Of Tender Document 621 Supply Of Cooling Fan Lt Motor Upto & Incl 11 Kw As Per Special Conditions Of Contract ( Technical ) Of Tender Document 622 Supply Of Cooling Fan Lt Motor 12-18 Kw As Per Special Conditions Of Contract ( Technical ) Of Tender Document 623 Supply Of Cooling Fan Lt Motor 111-150 Kw As Per Special Conditions Of Contract ( Technical ) Of Tender Document 624 Supply Of Fan Cover Lt Motor Upto & Incl 11 Kw As Per Special Conditions Of Contract ( Technical ) Of Tender Document 625 Supply Of Fan Cover Lt Motor 12-18 Kw As Per Special Conditions Of Contract ( Technical ) Of Tender Document 626 Supply Of Fan Cover Lt Motor 111-150 Kw As Per Special Conditions Of Contract ( Technical ) Of Tender Document 627 Supply Of End Shield Lt Motor Upto & Incl 11 Kw As Per Special Conditions Of Contract ( Technical ) Of Tender Document 628 Supply Of End Shield Lt Motor 12-15 Kw As Per Special Conditions Of Contract ( Technical ) Of Tender Document 629 Supply Of End Shield Lt Motor 111-150 Kw As Per Special Conditions Of Contract ( Technical ) Of Tender Document 630 Suply Of Bearing Cover Lt Motor Upto & Incl 11 Kw As Per Special Conditions Of Contract ( Technical ) Of Tender Document 631 Suply Of Bearing Cover Lt Motor 12-18 Kw As Per Special Conditions Of Contract ( Technical ) Of Tender Document 632 Suply Of Bearing Cover Lt Motor 111-150 Kw As Per Special Conditions Of Contract ( Technical ) Of Tender Document 633 Erection, Testing And Commissioning Of Motor On Existing Foundation Including Carriage From Stores To The Site, Unpacking, Placing On Foundation, Levelling, Fixing And Fitting Of All Components, Making Necessary Connections, Phase Checking, Meggering As Necessary All Complete With Labour And Materials As Per The Direction Of Engineer-In-Charge.- Small Equipment Requiring Tractor Trailer But Not Requiring Crane / Hydra Etc. ( Beyond 100 Kg. ) 634 Erection, Testing And Commissioning Of Motor On Existing Foundation Including Carriage From Stores To The Site, Unpacking, Placing On Foundation, Levelling, Fixing And Fitting Of All Components, Making Necessary Connections, Phase Checking, Meggering As Necessary All Complete With Labour And Materials As Per The Direction Of Engineer-In-Charge.- Equipment, Panels, Motor Etc. Weighing Above 500 Kg And Requiring Hydra And Tractor Trolley Etc.But <3Mt 635 Erection, Testing And Commissioning Of Motor On Existing Foundation Including Carriage From Stores To The Site, Unpacking, Placing On Foundation, Levelling, Fixing And Fitting Of All Components, Making Necessary Connections, Phase Checking, Meggering As Necessary All Complete With Labour And Materials As Per The Direction Of Engineer-In-Charge.- Equipment, Panels, Motor Etc.Weighing More Than 3 Mt And Requiring Crane And Tractor Trolley But <25Mt 636 Supply And Installation Of L&T / Siemenas Or Equilent Make Dol Motor Starter ( With All Acessaries Including O / L Relay Etc. ) Confirming To Is:13947-4 On Walls / Steel Structure, Connection Of Cables All Complete With Labour And Materials As Per Direction Of The Engineer- In-Charge- Upto 5.5Kw 637 Supply And Installation Of L&T / Siemenas Or Equilent Make Dol Motor Starter ( With All Acessaries Including O / L Relay Etc. ) Confirming To Is:13947-4 On Walls / Steel Structure, Connection Of Cables All Complete With Labour And Materials As Per Direction Of The Engineer- In-Charge- 5.5 To 7.5 Kw 638 Supply And Installation Of L&T / Siemenas Or Equilent Make Dol Motor Starter ( With All Acessaries Including O / L Relay Etc. ) Confirming To Is:13947-4 On Walls / Steel Structure, Connection Of Cables All Complete With Labour And Materials As Per Direction Of The Engineer- In-Charge-7.5 To 11Kw 639 Supply And Installation Of L&T / Siemenas Or Equilent Make Dol Motor Starter ( With All Acessaries Including O / L Relay Etc. ) Confirming To Is:13947-4 On Walls / Steel Structure, Connection Of Cables All Complete With Labour And Materials As Per Direction Of The Engineer- In-Charge- 11 To 15Kw 640 Transportation Of Lt Induction Motor For Rewinding Frompump Station To ContractorS Works And Back To Pump Station. This Includes Arranging Suitable Vehicle For To & Fro Transportation, Unloading & Loading The Motor At Rewinding Works. All Complete With Labour, Materials, Tools And Tackles As Per The Direction Of Engineer-In-Charge.Note: Lifting Facility To Put The Motor In The Vehicle At Our End Will Be Provided By Iocl For The Motors Of Capacity More Than 15 Kw.- Motor Upto 1.5 Kw 641 Transportation Of Lt Induction Motor For Rewinding Frompump Station To ContractorS Works And Back To Pump Station. This Includes Arranging Suitable Vehicle For To & Fro Transportation, Unloading & Loading The Motor At Rewinding Works. All Complete With Labour, Materials, Tools And Tackles As Per The Direction Of Engineer-In-Charge.Note: Lifting Facility To Put The Motor In The Vehicle At Our End Will Be Provided By Iocl For The Motors Of Capacity More Than 15 Kw.- Motor Above 1.5 Kw To 18.5 Kw 642 Transportation Of Lt Induction Motor For Rewinding Frompump Station To ContractorS Works And Back To Pump Station. This Includes Arranging Suitable Vehicle For To & Fro Transportation, Unloading & Loading The Motor At Rewinding Works. All Complete With Labour, Materials, Tools And Tackles As Per The Direction Of Engineer-In-Charge.Note: Lifting Facility To Put The Motor In The Vehicle At Our End Will Be Provided By Iocl For The Motors Of Capacity More Than 15 Kw.- Motor Above 75 Kw To 160 Kw 643 Online Condition Monitoring And Diagnostic Testing Of 6.6 Kv Ht Motors As Per Tender Specifications 644 Offline Condition Monitoring And Diagnostic Testing Of 6.6 Kv Ht Motors As Per Tender Specifications 645 Offline Diagnostic Testing Of Ht Cables As Per Tender Specifications 646 Fixed Charges For Transportation Of Equipments, Mobilisation Of Engineers & Instruments, Accomodation Arrangement By Contractor Itself During Work At Site, Lodging And Boarding Etc. For Carrying Out Work At Erpl Patna Pump Station.
Contract Date : 12 Apr, 2023   |   Contract Value : 28.83 Lakhs
BRR : 7913749 Tender For Package 1 Of Nagar Nigam Ayodhya Sewerage Scheme District-1 Part-Ii And District-1 Part-I Zone-1 And 2 - Sewer Laying 2 Excavation in foundation in ordinary soil (loam, clay & sand) including lift upto 1.5m and lead upto 50m watering & rammin of excavated earth into the tranches or into the space between the building and the sidesw of the foundatio or into the plinth and disposal of surplus earth upto a distance of 50m from centre of trenches. 3 0.00 to 1.50 m 4 1.50 to 3.00 m 5 3.00 to 4.50 m 6 4.50 to 6.00 m 7 6.00 to 7.50 m 8 Providing and laying granual material (graded stone aggregate 40mm nominal size) including watering, ramming consolidating and dressing complete- All work up to plinth level : 9 In Granular Bedding 10 Providing lay in Plain Cement Concrete in following proportion in foundation and floor including supply of all materials, labour, T&P etc. complete required for the work 1:4:8 with coarse sand and 4cm gauge stone ballast. 11 Same as above but 1.5-3.0 m BGL 12 Same as above but 3.0-4.5 m BGL 13 Same as above but 4.5-6.0 m BGL 14 Same as above but 6.0-7.5 m BGL 15 Providing lay in Plain Cement Concrete in following proportion in foundation and floor including supply of all materials, labour, T&P etc. complete required for the work 1:2:4 with coarse sand and 4cm gauge stone ballast. 16 Same as above but 1.5-3.0 m BGL 17 Same as above but 3.0-4.5 m BGL 18 Same as above but 4.5-6.0 m BGL 19 RCC work with cement, coarse sand and graded stone aggregate 20mm nominal size in proportion of 1:1.5:3 excluding supply of the reinforcement and its bending but including its fixing and binding with 0.5mm thick binding wire (to be supplied by the contractor) & including necessary centering and shuttering, supply of all materials labour, T&P etc. required for proper completion of work. 20 In RCC Bedding 21 Same as above but 4.5-6.0 m BGL 22 Same as above but 6.0-7.5 m BGL 23 In Boxing of Joint 24 Mild steel or iron work in R.C.C. work wrought to required shape as necessaty including bending for proper completion of work including supply of steel & wastage etc. 25 Provide all material ,labour and T&P etc. fixing of open timbering in trenches with 50 mm thick country wood planks, 150 X 75 mmsize sal wood wallers and 125mm dia. sal wood ballies for struts 1.5 m c/c including removal of all timbering after aying of sewer etc. all complete. 26 A. Open Timbering(0.0 TO 3.00m) 27 Provide all material ,labour and T&P etc. fixing of Closed timbering in trenches with 50 mm thick country wood planks, 150 X 75 mmsize sal wood wallers and 125mm dia. sal wood ballies for struts 1.5 m c/c including removal of all timbering after aying of sewer etc. all complete. 28 A. Close Timbering(0.00 TO 3.00m) 29 B. Close Timbering(3.00 TO 6.00m) 30 i. Close timbering left in trenches Used(3.00 TO 6.00m) 31 ii. Close timbering left in trenches Unused(3.00 TO 6.00m) 32 C. Close Timbering(6.00 TO 9.00m) 33 Disposal of surplus earth with municipal limits upto a distance of 8 km as per direction of E/I. 34 Providing non-pressure AC Pipe Class-2 with 1 No. AC Coupling with a set of three rubber ringsincluding testing of joints etc. complete. 35 200mm dia 36 250mm dia 37 Supply of R.C.C NP-3 pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete. Cost includes supply of rubber ring/gasket etc. 38 250mm dia 39 300mm dia 40 350mm dia 41 Supply of R.C.C NP-4 pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 Coarse sand) including testing of joints etc. complete. 42 250mm dia 43 300mm dia 44 350mm dia 45 400mm dia 46 Carting laying jointing and fill testing from (upto 8km) the following sizes of R.C.C NP-3 pipes and specials to the site of work, lowering them in to trenches and laying true to alignment and gradient including testing of pipeline (but excluding cost of trenching and cuting of pipes etc. for making of lengths but including making joint. 47 0.00 to 1.50 m 48 200mm dia 49 1.50 to 3.00 m 50 200mm dia 51 250mm dia 52 3.00 to 4.50 m 53 200mm dia 54 250mm dia 55 200mm dia 56 300mm dia 57 4.50 to 6.00 m 58 250mm dia 59 300mm dia 60 350mm dia 61 6.00 to 7.50 m 62 300mm dia 63 350mm dia 64 40mm dia 65 Supply and Pushing of MS casing pipe of specified thickness by trenchless method adopting micro-tunnelling or any suitable mechanical technology or technology approved by Railway below ground at all depth under running traffic condition as per railway/department standard including carrying out survey work at the job site for determining underground cable trenches like telephone, cable, water & sanitary lines and resistivity test for finding the soil strata using necessary equipment’s for completion of works, mobilizing of machineries and specialized crew at the job site complete in all respect, including excavation of driven pit and exit pit (upto 3 metre depth) with proper protection at three sites with shoring sheets and ISMBs. Providing MS cutting edges for front shield and Constructing thrust bed at designated level. Necessary de-watering and providing concrete foundation at the base of the driven pit, PVC/Rubber saddle as per the requirement of Railway Authority, crane for handing of pipe and any other machinery, tools, and tackles required, construction of temporary works as per requirement and as per approved by railway authorities, specification and the direction of the Engineer. Note- 1. All pipe used for trenchless must have Protective coating/ lining as per suitable IS code 2. Length of pipe shall be measured in between the outer wall of two manholes / Inspection chambers. Pipe in the anhole /inspection chamber’s wall shall deemed to be included in the item of manhole/inspection chamber shall not be payable. 66 500mmMS pipe with thickness not less than 12 mm 67 4.5 - 6.0 BGL 68 6.0 - 7.5 BGL 69 600mm MS pipe with thickness not less than 12 mm 70 4.5 - 6.0 BGL 71 700mm MS pipe with thickness not less than 14 mm 72 6.0 - 7.5 BGL 73 Supply of all materials, labour, T & P etc. and constructing Brick circular M.H. of following sizes as type design and drawing including dewatering etc comp. (as per unit estimate) 74 Circular Type 0.00 to 1.65 m (900mm dia) 75 Circular Type 1.66 to 2.30 m (1200mm dia) 76 Circular Type 2.31 to 3.00 m (1500mm dia) 77 Circular Type 3.00 to 4.00 m (1500mm dia) 78 Circular Type 4.00 to 5.00 m (1500mm dia) 79 Circular Type 5.00 to 6.00 m (1500mm dia) 80 Circular Type 6.00 to 7.00 m (1500mm dia) 81 Supply of all materials, labour, T & P etc. and constructing RCC circular M.H. of following sizes as type design and drawing including dewatering. (as per unit estimate) 82 Circular Type 7.00 to 8.00 m (1500mm dia) 83 Circular Type 8.01 to 9.00 m (1500mm dia) 84 Supply of all material labour and T&P etc. and providing barricading of open trenche. 85 Cutting of Road in sewer laying 86 Bitumen Road 87 CC Road 88 BOE Road 89 Interlock Tile Road 90 Reinstatment of road in sewer laying as per PWD/Jal Nigam specification 91 Bitumen RoadFor Nagar Nigam 92 Bitumen RoadFor PWD 93 CC Road (230 mm thick) 94 CC Road (280 mm thick) 95 BOE Road 96 Tile Road 97 Local Sand Filling in Trenches on PWD roads and For sewer laid at depth more than 4 m Below ground Level 98 Shifting of 11 Kv underground electrictity cable including supply of all materials, labour, Charges to Electricity department and T&P all etc. 99 Shifting of 33Kv underground electrictity cable including supply of all materials, labour, Charges to Electricity department and T&P all etc. 100 Dewatering of Subsoil Water from 4.5 m to 6 mtr depth BGL 101 Dewatering of Subsoil Water from 6 m to 9 mtr depth BGL 102 Siffting of Following HDPE and DI K 7 pipe including supply of all material labour T&P with all jointing materials etc comp . 103 90 mm dia HDPE 104 110 mm dia HDPE 105 140 mm dia HDPE 106 160 mm dia HDPE 107 200 mm dia DI K-7 108 250 mm dia DI K-7 109 300 mm dia DI K-7 110 350 mm dia DI K-7 111 400 mm dia DI K-7 112 Dismentling of following type of road and stacking of useful materials including supply of all materials, labour, T&P etc. complete. 113 BOE Road 114 C.C. Road 115 Bitumen Road 116 Interlocking 117 Reinstatement of following type road As per PWD 118 BOE Road 119 C.C. Road 120 Bitumen Road 121 Interlocking 122 Supply of all materials, labour T&P and provide Inter connection of new pipe line with old existing pipe line. 123 SEWER HOUSE CONNECTION 124 Dismanting of different type of road surfaces:- 125 C.C. Roads 126 Bitumin road 127 Interlocking tiles 128 BOE roads 129 Reinstatement of Road Surface 130 C.C. Roads 131 Bitumin road 132 Interlocking tiles 133 BOE roads 134 Provision for following types of Culvert crossing along the alignment of pipe line complete as per instructions of Engineer ‐in ‐charge. (casing of pipe is done by concreting) 135 Construction of Sewer Connecting Chamber of size 60 x 60 x 75 cm 136 Construction of House Connecting Chamber of size 30 x 30 x 45 cm 137 Making Domestic Sewer connection using 120mm (OD) PN 6 HDPE Pipe from H.C.C to S.C.C 138 Laying of Sewer line from Sewer Inter connecting chamber to Manhole using 160mm dia PN 6HDPEpipe. 25 % houses in Narrow lanes. 139 Laying of Sewer line from Sewer Inter connecting chamber to Manhole using 150mm dia AC MAZZA Class IIpipe. 75 % Houses 140 Making Domestic Sewer connection using 120mm (OD) PN-6 HDPE Pipe from house collecting grey and black water to H.C.C (75 % of household) 141 Making Domestic Sewer connection using 120mm (OD) PN-6 HDPE Pipe from house collecting grey and black water to Manhole Direct without Connection to I.C.C. (25 % of house hold) 142 Construction ofscreen channel including excavation, P.C.C. with cement, coarse sand, stone ballast 40 mm (1:4:8), R.C.C. with cement, coarse sand, stone ballast 20 mm (1:1.5:3) and using HYSD 500 TMT bars as per type drawing and design etc. complete 143 Screen channel before IPS-1 144 Screen channel before IPS-2 145 Construction ofsumpwell at IPS including excavation R.C.C. work using cement, coarse sand and graded aggregate 20 mm (1:1.5:3), P.C.C. work with cement, coarse sand and stone ballest 40 mm (1:2:4) also using HYSD 500 TMT bars as per type drawing and design 146 Sump well at IPS-1, size 7.00 m dia x 10.55 m deep 147 Sump well at IPS-2, size 10.00 m dia x 11.06 deep 148 Excavatrion in foundation in ordinary soil (loam, clay & sand) including lift upto 1.5m and lead upto 50m watering & rammin of excavated earth into the tranches or into the space between the building and the sidesw of the foundatio or into the plinth and disposal of surplus earth upto a distance of 50m from centre of trenches. 149 Supply of DI Pipes, class K-9 with rubber gasket, conforming to IS:8329, FOR destination (store at Loni) including all taxes and insurance etc. complete. 150 400 mm dia pipe IPS-1 to STP 151 500 mm dia pipe IPS-2 to MH-2834 152 Supply of specials such as duck foot bends tail pieces, bends etc. @10% of item no. 2 153 Carting laying jointing and fill testing from store (upto 8km) the following sizes of D.I. Pipes (Class K-9) and specials to the site of work, lowering them in to trenches and laying true to alignment and gradient including testing of pipeline (but excluding cost of trenching and cuting of pipes etc. for making of lengths but including making joint. 154 400mm dia. 155 500mm dia. 156 RCC work with cement, coarse sand and graded stone aggregate 20mm nominal size in proportion of 1:1.5:3 excluding supply of the reinforcement and its bending but including its fixing and binding with 0.5mm thick binding wire (to be supplied by the contractor) & including necessary centering and shuttering, supply of all materials labour, T&P etc. required for proper completion of work. 157 Thrust Block 158 Mild steel or iron work in R.C.C. work wrought to required shape as necessaty including bending for proper completion of work including supply of steel & wastage etc. 159 Dismantling of roads for laying of pipe line including sorting out and stacking of serviceable materials,stacking and disposal of unserviceable materials upto a distance of 50 m. 160 BT Road 161 Reinstatement of following type of roads dismantled during laying of pipe line including supply of all materials, labour and T & P etc. required for proper completion of the work. 162 BT Road 163 Air / Vacuum relies valves specially for sewerage services and size as per OEM. Manually controlled isolation valve for rising main. 164 20mm dia 165 Providing & construction of Air Valve Chamberas per unit estimate. 166 size 350x350x500mm 167 Providing & construction of Flow Meter Chamberas per detailed estimate. 168 Size 1.5x1.00x2.00 m 169 Providing & construction of Combined Chamber for Sluice Valve, NRV & Air Valve size 2.50 x 1.50 x 2.00m as per detailed estimate. 170 Crossing Railway Line by trenchless technology with 500 MM DI K 9 Carrier , 700 MM & 900 MM dia MS pipe as Casing. Including supply of pipe and all material, labour and T&P. 171 Construction of Staff Quarter as per approved design and drawing from department 172 Construction of Meter Room Size (3.0mx 3.0m x 4.50m) as per detailed estimate. 173 Construction of L.T. Panel Room Size (5.0mx 4.0m x 4.50m) as per detailed estimate. 174 Construction of H.T. Panel Room Size (5.0mx 4.0m x 4.50m) as per detailed estimate. 175 Portable Bio Toilet 176 Construction of Pump House (6.0 m x 5.0 m) 177 Construction of D.G. Platform Size-8.00mx2.50m, 2Nos. 178 Site development including levelling, dressing & horticulture etc. complete. 179 Storm Water Drain at IPS Site 180 Providing & Construction of Boundary Wall as per unit estimate. Pile and RCC column foundation 181 Providing & Construction of Boundary Wall as per unit estimate. Brickwork 182 25mm th. PCC 1:2:4 floor with cement, coarse sand and 20mm gauge stone ballast with base concrete (75mm th.) 1:4:8 cement, local sand and brick ballast of 40mm gauge. 183 Supply and Fixing 3.6m wide iron gate and with pillars. As per Unit Estimate. 184 Providing & Construction of 4.0m wide C.C. Road 185 Internal Road & Approach Road 186 Rain Water Harvesting at IPS Site. 187 Administrative Building as per approved design and drawing from department with provision of furniture, AC and campus developement 188 Scada Control Room as per approved design and drawing from department with provision of furniture, AC and campus developement 189 E / M works 190 IPS -1 191 Pumping Plant 192 SITC of submersible non clog pump single stage having two vanes semi open shrouded impeller coupled with submersible motor of 4600 LPM, Rating 415 Volt ±10%,3 phase 50 Hz, solid handling capacity 100mm, suitable to pump sewage with an specific gravity =1.05 ( approx) having following construction of material.Casing-2% Ni Cl. IS.210 grade F.G.220 with hardness 275 BHN.Impeller-Stainless steel CF-8M shaft-stainless steel AISI-410 Discharge of Pump 4600 LPM Speed=1500 RPM along with all required accessories and mounting arrangeents e.gGuide Pipe, Lifting Chain, Clamps,Foundation, Required Sensors, Power and Control Cables upto 50 M distance complete in all respects. 193 Soft starter suitable for operation on 400 ± 10% volts,3 phase, 50 Hz,AC supply suitable for starting and running of Above electric motor and suitable for 8 to 12 starts and stops per Hr. 194 Motor Control Panel for Pumping Plant 195 MS sheet fabricated factory wired dust & vermin proof cubical and floor mounting type control panel Scada Compatible comprising of 1 nos. ACB incomer cubical panel incoming from LT Switchgear Panel and another 01 No. incomer from DG AMF Panel having electronic interlock arrangements along with 6 nos. outgoing for pumps with 200 Amp MCCB and 3 nos. outgoing for misc. loads (L&F etc.) with 100/63/32 Amp MCCB/MCB. The Panel Must consist of Inbuilt or Seperate Control Panel consisting of Features like. Auto Start and Stop of Motor Pumpset in accordance to Sump Level, Motor Protection Relays, Under Voltage, Over Voltage and Thermal Protection, Over Curret Protection, Earth Fault Protection, Short Circuit Protection etc complete in all Respect with touch Display. 196 Main Pipings and Valves 197 Sluice Valve 200mm with actuator for pumps 198 Sluice Valve 400mm dia with actuator for Common Header 199 Reflux valve 200mm dia N.B. 200 Reflux valve 400mm dia N.B. For Common Header 201 Dismantling joints.200mm 202 Dismantling joints.400mm 203 Level Sensor and Level switches 204 Column Pipe for Pumps with Common Header havng CI Pipes & Fitting with enlarger, distance piece of different size, 90 deg. Bend, all flange tee, DF pipe suitable Size 3 m, 2m & 1 M, Reducer/Enlarger, Blind Flange, Common Header etc complete in all respects for complete IPS. 205 Nut bolts & washer S.S. and M.S. with Required Rubber Packings 206 Pressure Transmitter 207 Provision for 400 mm dia electromagnetic flow meter complete with display unit including power cable installation testing & commissioning suitable to measure . 208 Auto phase reversal unit with inbuilt time delay & enclosure conforming to IEC: 60947-1 & IEC:60947-b-1) (630 Amps) or as per actual design for complete IPS load 209 Complete Cabling for IPS including all power & control cable of all equipments at IPS . 210 SITC of E.O.T. crane of 5 tonne capacity along with gantry girders, chain pulley, block and geared trolley suitable for 10 m span with SS chain, 15m clear lift complete in all respect for pump house. Detailed specifications are as below confirming to I.S. 3177 and I.S.3832 Indef make chain Pulley Block Capacity 5 Tone with 10 mts lift and hand chain of 6 meters along with indef make traveling trolley capacity 5 Tone with 6 m hand chain fitted on gantry Girders and transverse movement rail arrangement. 211 Toolbox of 30x18x11Fabricated from 18 Gauge MS sheet fuly black painted comprising of followings. Ring Spanner of 12 PCs-1Set, D/E Spanners of 12 PCs-1Set, Adjustable wrench12-1No., Pipe wrench 24size-12No., Pipe wrench 18 size-1No, Pipe wrench 12 Size-1No.,Bearing Puller-1No.,Crimpling Tools upto 400mm², Heavy duty sockets 20mm to 50mm-1Set, Chain wrench 36-2Nos.Omsi;ated plier-1No.L&Key set-1Set,Screwdriver-1Set,Insulation Resistance Tester upto 5000V, Continuity Tester-1 No, Multimeter-1 NO,Rotary oil pump-1 No. Plier Set-1 No Etc. as per Direction of Engineer in-Charge and to cater Operation and Maintenance Works of all Equipments installed. 212 Fire Extinguisher arrangements confirming to ISS and as per site requirements. 213 12.5/25mm thick Rubber Electric Resistance sheet as per ISS for LT&H.T Panels and Starters as Per Design and Requirements 214 Miscellaneous Items Such as First Aid Box, Steel Almirah of 6’x3’in 20 Gaugesheet, Required Furniture, Steel Tubular chair, Steel tubular table, Fire Stand with bucketsalong with Required Temporary Site Office Arrangement with desktop, computer, Printer, Computer/SCADA Opearator and Stationary, Vehicle for watch and Ward During Construction and Trail Run Upto Handover 215 Installation & Commissioning of all 6 Nos. Pump set, starters,Piping & Valves, Gauges as mentioned in above including proper Cabling, Termination and earthing, required chequered plate complete in all Respect 216 Testing of each pumps at manufacturer works and also at site. 217 Painting of all pumps piping and valves with two coat black enamel paint. 218 Internal and External internal wiring of pump house H.T. Room L.T. control room, Meter Room, D.G.Room, Store and staff quarters with Lights, Fan, Exhaust Fans and Accessories Complete in all Respect 219 Pole Mounted Solar based campus lighting with battery bank 220 Construction of trusses with the help of M.S. Channels, M.S. angle irons, nut bolts and rivets as required for supporting the out going and common header line in the pump house in single stream for the pumps to be installed. 221 SITC of water supply arrangements with Mini tubewell 100mm PVC pipe including submersible pump of suitable size for campus water requirement complete in all respect e.g water tank, piping arrangements. 222 Manual Bar Screen 223 SITC of suitable fixed type manual coarse bar screen for Peak Flow having 20mm bar spacing, 10mm bar thickness and angle of installation 60° ,MOC-SS-304. 224 Motor Control Panel for Pumping Plant 225 SITC of SCADA Compatible suitable multirake coarsebar screen having 20 mm bar spacing , 10 mm bar thickness, MOC- SS-304.and angle of installation 75° duly followed with diffrential level sensor arrangement conveyor system including electric motor, starter, cable etc of suitable size as per latest IS and direction of Engineer In Charge 226 Sluice Gate 227 SITC of SCADA Compatible Suitable C.I.Sluice gate as per actual design requirements confirming to IS13349/92 or AWWA AC-501 having F shaped wall thimble mounted , Actuator operated, upward opening, rising spindle type,flush bottom closure arrangement, open top frame gate with Positioning card 228 Electric Substation 229 SITC of 11/0.415 KV Electric Substation with 01 working + 01 Standby Electric Transformer as per actual Design Requirements along with 11 KV HT Switchgear Panel with 1 Incomer and 2 Outgoing VCB Panel with all required protections. The switchgear panel consists of Bus-Coupler along with electronic interlock, metering arrangements, DC power supply/ SMPS, Gravel Filling, Neutral Grounding, Fencing around substation, Fire fighting arrangements, required power and control cabling, route markup, cable trenches, cable tray arrangements, complete in all respects 230 SITC of SCAD compatible LT Switch gear Panel with 02 Nos. incomer from 02 Transformers and 01 No outgoing cubical with all required protections and smart energy metering arrangements. The job also includes required power and control cables, Cable trenches, cable trays, earthing arrangements etc complete in all respects 231 Floor mounting extensible type dust and vermin proof APFC Panel with auto power factor correction relay, LT contactors suitable size capacitor bank,TP switch fuse unit complete with internal wiring suitable for 315 KVA load. The capacity of power capacitor bank will be suitable to improve the power factor uo to 0.99 232 DG Sets 233 SITC of DG Sets with reuired foundation, anti vibration mounting arrangements, earthing, SCADA compatible AMF Panel, Synchronizing panel, power and control wiring, cable tray and trenches complete in all respects with exhaust piping arrangements as per UPPCB Norms. 234 Necessary approval from Electrical Safety Department for IPS Substation and Swithgears 235 Trial & Run of IPS 236 HSD Oil During Trail and Run Period 237 SCADA of IPS with all Required Hardware like RTU, Comunication Devices, firewall, Surge arrester etc along with required Software, Field Instruments and interconnection of differtent equipments e.g Motor, Pumpset, Energymeter, Switchgear, DG Set, Flowmeter, Valves, Gate, Screen etc complete job in all respects 238 Trial & Run upto handing over of IPS with required arrangements of operator, other consumables for maintenance, Required Labour, TnP, Vehicles Complete in all respects 239 IPS -2 240 Pumping Plant 241 SITC of submersible non clog pump single stage having two vanes semi open shrouded impeller coupled with submersible motor of 7400 LPM, Rating 415 Volt ±10%,3 phase 50 Hz, solid handling capacity 100mm, suitable to pump sewage with an specific gravity =1.05 ( approx) having following construction of material.Casing-2% Ni Cl. IS.210 grade F.G.220 with hardness 275 BHN.Impeller-Stainless steel CF-8M shaft-stainless steel AISI-410 Discharge of Pump 4600 LPM Total Head= 50 m Speed=1500 RPM along with all required accessories and mounting arrangeents e.gGuide Pipe, Lifting Chain, Clamps,Foundation, Required Sensors, Power and Control Cables upto 50 M distance complete in all respects. 242 Soft starter suitable for operation on 400 ± 10% volts,3 phase, 50 Hz,AC supply suitable for starting and running of above electric motor and suitable for 8 to 12 starts and stops per Hr. 243 Motor Control Panel for Pumping Plant 244 MS sheet fabricated factory wired dust & vermin proof cubical and floor mounting type control panel Scada Compatible comprising of 1 nos. ACB incomer cubical panel incoming from LT Switchgear Panel and another 01 No. incomer from DG AMF Panel having electronic interlock arrangements along with 6 nos. outgoing for pumps with 400 Amp MCCB and 6 nos. outgoing for misc. loads (L&F etc.) with 100/63/32 Amp MCCB/MCB. The Panel Must consist of Inbuilt or Seperate Control Panel consisting of Features like. Auto Start and Stop of Motor Pumpset in accordance to Sump Level, Motor Protection Relays, Under Voltage, Over Voltage and Thermal Protection, Over Curret Protection, Earth Fault Protection, Short Circuit Protection etc complete in all Respect with touch Display. 245 Main Pipings and Valves 246 Sluice Valve 250mm with actuator for pumps 247 Sluice Valve 500mm dia with actuator for Common Header 248 Reflux valve 250mm dia N.B. 249 Reflux valve 500mm dia N.B. For Common Header 250 Dismantling joints.250mm 251 Dismantling joints.500mm 252 Level Sensor and Level switches 253 Column Pipe for Pumps with Common Header havng CI Pipes & Fitting with enlarger, distance piece of different size, 90 deg. Bend, all flange tee, DF pipe suitable Size 3 m, 2m & 1 M, Reducer/Enlarger, Blind Flange, Common Header etc complete in all respects for complete IPS. 254 Nut bolts & washer S.S. and M.S. with Required Rubber Packings 255 Pressure Transmitter 256 Provision for 500 mm dia electromagnetic flow meter complete with display unit including power cable installation testing & commissioning suitable to measure . 257 Auto phase reversal unit with inbuilt time delay & enclosure conforming to IEC: 60947-1 & IEC:60947-b-1) (630 Amps) or as per actual design for complete IPS load 258 Complete Cabling for IPS including all power & control cable of all equipments at IPS . 259 SITC of E.O.T. crane of 5 tonne capacity along with gantry girders, chain pulley, block and geared trolley suitable for 10 m span with SS chain, 15m clear lift complete in all respect for pump house. Detailed specifications are as below confirming to I.S. 3177 and I.S.3832 Indef make chain Pulley Block Capacity 5 Tone with 10 mts lift and hand chain of 6 meters along with indef make traveling trolley capacity 5 Tone with 6 m hand chain fitted on gantry Girders and transverse movement rail arrangement. 260 Toolbox of 30x18x11Fabricated from 18 Gauge MS sheet fuly black painted comprising of followings. Ring Spanner of 12 PCs-1Set, D/E Spanners of 12 PCs-1Set, Adjustable wrench12-1No., Pipe wrench 24size-12No., Pipe wrench 18 size-1No, Pipe wrench 12 Size-1No.,Bearing Puller-1No.,Crimpling Tools upto 400mm², Heavy duty sockets 20mm to 50mm-1Set, Chain wrench 36-2Nos.Omsi;ated plier-1No.L&Key set-1Set,Screwdriver-1Set,Insulation Resistance Tester upto 5000V, Continuity Tester-1 No, Multimeter-1 NO,Rotary oil pump-1 No. Plier Set-1 No Etc. as per Direction of Engineer in-Charge and to cater Operation and Maintenance Works of all Equipments installed. 261 Fire Extinguisher arrangements confirming to ISS and as per site requirements. 262 12.5/25mm thick Rubber Electric Resistance sheet as per ISS for LT&H.T Panels and Starters as Per Design and Requirements 263 Miscellaneous Items Such as First Aid Box, Steel Almirah of 6’x3’in 20 Gaugesheet, Required Furniture, Steel Tubular chair, Steel tubular table, Fire Stand with bucketsalong with Required Temporary Site Office Arrangement with desktop, computer, Printer, Computer Opearator and Stationary, Vehicle for watch and Ward During Construction and Trail Run Upto Handover 264 Installation & Commissioning of all 6 Nos. Pump set, starters,Piping & Valves, Gauges as mentioned in above including proper Cabling, Termination and earthing, required chequered plate complete in all Respect 265 Testing of each pumps at manufacturer works and also at site. 266 Painting of all pumps piping and valves with two coat black enamel paint. 267 Internal and External internal wiring of pump house H.T. Room L.T. control room, Meter Room, D.G.Room, Store and staff quarters with Lights, Fan, Exhaust Fans and Accessories Complete in all Respect 268 Pole Mounted Solar based campus lighting with battery bank 269 Construction of trusses with the help of M.S. Channels, M.S. angle irons, nut bolts and rivets as required for supporting the out going and common header line in the pump house in single stream for the pumps to be installed. 270 SITC of water supply arrangements with Mini tubewell 100mm PVC pipe including submersible pump of suitable size for campus water requirement complete in all respect e.g water tank, piping arrangements. 271 Manual Bar Screen 272 SITC of suitable fixed type manual coarse bar screen for Peak Flow having 20mm bar spacing, 10mm bar thickness and angle of installation 60° ,MOC-SS-304. 273 Mechanical Bar screen 274 SITC of SCADA Compatible suitable multirake coarsebar screen having 20 mm bar spacing , 10 mm bar thickness, MOC- SS-304.and angle of installation 75° duly followed with diffrential level sensor arrangement conveyor system including electric motor, starter, cable etc of suitable size as per latest IS and direction of Engineer In Charge 275 Sluice Gate 276 SITC of SCADA Compatible Suitable C.I.Sluice gate as per actual design requirements confirming to IS13349/92 or AWWA AC-501 having F shaped wall thimble mounted , Actuator operated, upward opening, rising spindle type,flush bottom closure arrangement, open top frame gate with Positioning card 277 Electric Substation 278 SITC of 11/0.415 KV Electric Substation with 01 working + 01 Standby Electric Transformer as per actual Design Requirements along with 11 KV HT Switchgear Panel with 1 Incomer and 2 Outgoing VCB Panel with all required protections. The switchgear panel consists of Bus-Coupler along with electronic interlock, metering arrangements, DC power supply/ SMPS, Gravel Filling, Neutral Grounding, Fencing around substation, Fire fighting arrangements, required power and control cabling, route markup, cable trenches, cable tray arrangements, complete in all respects 279 SITC of SCAD compatible LT Switch gear Panel with 02 Nos. incomer from 02 Transformers and 01 No outgoing cubical with all required protections and smart energy metering arrangements. The job also includes required power and control cables, Cable trenches, cable trays, earthing arrangements etc complete in all respects 280 Floor mounting extensible type dust and vermin proof APFC Panel with auto power factor correction relay, LT contactors suitable size capacitor bank,TP switch fuse unit complete with internal wiring suitable for 315 KVA load. The capacity of power capacitor bank will be suitable to improve the power factor uo to 0.99 281 DG Sets 282 SITC of DG Sets with reuired foundation, anti vibration mounting arrangements, earthing, SCADA compatible AMF Panel, Synchronizing panel, power and control wiring, cable tray and trenches complete in all respects with exhaust piping arrangements as per UPPCB Norms. 283 Necessary approval from Electrical Safety Department for IPS Substation and Swithgears 284 Trial & Run of IPS 285 HSD Oil During Trail and Run Period 286 SCADA of IPS with all Required Hardware like RTU, Comunication Devices, firewall, Surge arrester etc along with required Software, Field Instruments and interconnection of differtent equipments e.g Motor, Pumpset, Energymeter, Switchgear, DG Set, Flowmeter, Valves, Gate, Screen etc complete job in all respects 287 Trial & Run upto handing over of IPS with required arrangements of operator, other consumables for maintenance, Required Labour, TnP, Vehicles Complete in all respects 288 SCADA MCS (MASTER CONROL STATION) with Interactive Display for control room including required accessories, workstation, Desktop PC, Printers and Furniture as per Direction of Engineer Incharge Complete in all respect. The MCS should be interconnectedto all IPS (Package 1, Package 2) and STP Scadasystem along with Central Server at Ayodhya.
Contract Date : 12 Aug, 2025   |   Contract Value : 92.47 Crore
Disclaimer

We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.

Tender Detail
Website https://etender.cpwd.gov.in/login.html
Quantity 0
MSME Exemption No
Tender Type Open Tender
Startup Exemption Click Here
Competitive Bidding NCB
Similar Tenders
TENDER INSIGHTS

858

Electric Tenders
Live
CLICK TO KNOW MAXIMUM WIN

Tell us about your Product / Services,

We will Find Tenders for you

🇮🇳 +91
TenderDetail
Loading tenders