TDR : 56368769
Central Public Works Department

Tender Brief :

Kolkata, West Bengal

Servicing & Overhauling Of 25 HP & 40 HP Centrifugal Pump Motor Unit I/C. Replacement Of Non-Functional Accessories I.E. Butterfly Valves, Gate Valves, Pipes & Fittings I/C. Painting In Pump House, 2Nd MSO Building At Nizam Palace Campus, Kolkata.

Published: 08 Jul 2026
Opening: 15 Jul 2026
Closing: 15 Jul 2026
Amount: 3.59 Lakhs
EMD: 7182
Tender Fee: Ref. Documents


Works AC Pipes Accounting Services Acoustical Work Advertising Agency Aerial Advertisement
3
Days Left
Tender Summary / Eligibility Criteria
Servicing & Overhauling Of 25 HP & 40 HP Centrifugal Pump Motor Unit I/C. Replacement Of Non-Functional Accessories I.E. Butterfly Valves, Gate Valves, Pipes & Fittings I/C. Painting In Pump House, 2Nd MSO Building At Nizam Palace Campus, Kolkata.
Documents Download All
871c7e94-9a56-4f17-b973-e9f4de192323
871c7e94-9a56-4f17-b973-e9f4de192323.html
DocumentsList
DocumentsList.zip
No Boq
No Corrigendum
Probable Bidders

AI engine predicts probable bidders to help you bid strategically.

MSME Exception
Explore More →
Technical
Tender involves procurement of high capacity electrical equipment including diaphragm coupling of pump & motor with 90kW capacity at 2900 RPM. The project scope includes installation, testing, commissioning and operational handover.
Previous / Similar Result
BRR : 9262505 Tender For Maintenance And Repairs To Submersible Pumps, Centrifugal Pumps, Star Delta Starters, Mccbs, Power Contactors, Control Panels Along With Connected Items At Afs Bidar; 2 Disconnecting and removing unserviceable MCCB, 4 pole, 200 Amps and S&F MCCB, 4 pole, 200 Amps, 50 Hz, 415 volts, rupturing capacity 50 KA including connecting the cables complete all as specified and as directed. 3 Disconnecting and removing unserviceable MCCB, 4 pole, 160 Amps and S&F MCCB, 4 pole, 160 Amps, 50 Hz, 415 volts,rupturing capacity 36 KA including connecting the cables complete all as specified and as directed. 4 Disconnecting and removing unserviceable MCCB, 3 pole, 160 Amps and S&F MCCB, 3 pole, 160 Amps, 50 Hz, 415 volts,rupturing capacity 36 KA including connecting the cables complete all as specified and as directed. 5 Disconnecting and removing unserviceable Automatic star/delta starter and S & F Automatic star/delta starterinSS enclosure with relay max range 13 to 21 Amps, 415V/440V and 3 Nos of Power Contactors of capacity 32 Amps, Prewired with ON/OFF Buttons complete including connecting the cable all as specified and as directed. 6 Disconnecting and removing unserviceable Automatic star/delta starter and S & F Automatic star/delta starterinSS enclosure with relay max range 20 to 32 Amps, 415V/440V and 3 Nos of Power Contactors of capacity 40 Amps, Prewired with ON/OFF Buttons complete including connecting the cable all as specified and as directed. 7 Disconnecting and removing unserviceable Automatic star/delta starter and S & F Automatic star/delta starterinSS enclosure with relay max range 28 to 42 Amps, 415V/440V and 3 Nos of Power Contactors of capacity 42 Amps, Prewired with ON/OFF Buttons complete including connecting the cable all as specified and as directed. 8 Disconnecting and removing unserviceable DOL starter and S & F DOL starterType - MK1, 15A, 3 Phase, 50 Cycles, Relay Range up to 9-14A, 415V/440V including connecting the cable complete all as specified and as directed. 9 Disconnecting and removing unserviceable 3Pole Contactor and S & F 3 Pole Contactor 32 Amps, Coil Voltage : 415V, 50 Hz including connecting the cable complete all as specified and as directed. 10 All as per Serial Item No 8 here-in-before, but of Contactor of 3 Pole 18 Amps 11 Disconnecting and removing unserviceable submersible cable 10 Sqmm 3 core and S&F submersible cable 10 Sqmm 3 core 1100 volts PVC sheathed & PVC insulated copper conductor ISI marked complete all as specified and as directed. 12 All as per Serial Item No 10 here-in-before, but cable of 3 core 6 Sq mm 13 Disconnecting and removing unserviceable Submersible pump set from the Bore well along withGI Lowering pipe, submersible cable, and pump sets, carrying out Servicing/ overhauling, finding out the faults, lowering the pump set back into bore well in its original position including testing and commissioning complete of submersible Pump set of capacity 5/6 HPNotes for Sl Item Nos12 to 14 :-(i) Cost of rewinding and replacement of spares such asBearings, Bushes, Shaft, Submersible Cable, lowering Pipes, Heavy Duty GI Sockets will be measured and paid as supply only under respective items.(ii)All consumable items required for satisfactory completion of job shall be deemed to be included in the quoted rate.(iii) The labour element required for fixing all the spares except rewinding is deemed to be included in the unit rate quoted 14 All as per Serial Item No 12 here-in-before, but for submersible pump of 7.5 / 10 HP capacity 15 All as per Serial Item No 12 here-in-before, but for in open well of 30 m deep and submersible pump of 25 to 30 HP capacity 16 Disconnecting and removing Serviceable cable connection of Centrifugal pump set along with Suction and Delivery GI Pipe connections, Valves etc, carrying out servicing / overhauling including finding out faults if any, re-fixing back the pumpset after carrying out repairs in its original position re-connecting the cables, suction and delivery pipelines & Valves testing and commissioning complete for Centrifugal Pump set of Capacity 3/ 5 /6 HP.Notes for Serial Item Nos 15 to 19 :-(i) Cost of rewinding and spares such as Impellers, Bearings, Bushes, Shaft,Cables, Pipes, medium grade GI Sockets will be measured and paid as supply only under respective items.(ii) Any spares not specified here-in-after in the BOQ, but are essentially required for the proper functioning of pump, shall be deemed to be included in the unit rate quoted,(iii) The labour element required for fixing all the spares except rewinding shall be deemed to be included in the quoted rate. 17 All as per item No 15 above but Centrifugal Pump set of Capacity 7.5/10 HP 18 All as per item No 15 above but Centrifugal Pump set of Capacity 12.5/15 HP 19 All as per item No15 above but Centrifugal Pump set of Capacity 20 HP 20 All as per item No 15 above but Centrifugal Pump set of Capacity 25/30 HP 21 Supply only GI Pipe 80mm dia/bore medium grade (Column pipe) with both sides threadingISI Marked complete. Note :-Labour cost for lowering & threading etc shall be included in unit rate quoted for Sl Item No 12 to 19 here-in-above. 22 Supply only GI Pipe 100mm dia/bore medium grade (Colum pipe 3 m length each) with both sides threadingISI Marked complete. Note :-Labour cost for lowering & threading etc shall be included in unit rate quoted for Sl Item No 12 to 19 here-in-above. 23 Disconnecting, removing unserviceable / burnt out windings of submersible motors carefully, rewinding with fine enamelled bare copper conductor of same gauge weight, turns, and keeping the core and windings into the hot air oven till the moisture evaporates etc and refixing/assembling the same in its original position complete for Submersible Motor of Capacity 5 to 6 HP. 24 All as per item No 22 here in above but for Submersible motor for Capacity 7.5/10 HP 25 All as per item No 22here in above but for Submersible motor for Capacity 25/30 HP 26 All as per item No 22here in above but for Centrifugal Motor for Capacity 3 to 6 HP 27 All as per item No 22here in above but for Centrifugal Motor for Capacity 7.5/10 HP 28 All as per item No22here in above but for Centrifugal Motor for Capacity 12.5/15 HP 29 All as per item No 22here in above but for Centrifugal Motor for Capacity 20 HP 30 All as per item No 22here in above but for Centrifugal Motor for Capacity 25/30HP 31 Supply only Stainless Steel Shaft including Polishing, Machining, threading, Metalling and necessary lathe work to match the shaft for Submersible Pump set of Capacity 5 to 6 HP 32 All as per item No 30here in above but for Submersible Pump set for Capacity 7.5/10HP 33 All as per item No 30here in above but for Submersible Pump set for Capacity 25 to 30 HP 34 All as per item No 30here in above but for Centrifugal Pump set for Capacity 3 to 6 HP 35 All as per item No 30here in above but for Centrifugal Pump set for Capacity 7.5 /10HP 36 All as per item No 30here in above but for Centrifugal Pump set for Capacity 12.5/15 HP 37 All as per item No 30here in above but for Centrifugal Pump set for Capacity 20 HP 38 All as per item No 30here in above but for Centrifugal Pump set for Capacity 25/30HP 39 Supply only new bearing of existing size and capacity to suit with existing centrifugal Pump set for Capacity 5HP. 40 All as per item No 38here in above but forCentrifugal Pump set for Capacity 7.5 HP 41 All as per item No 38 here in above but forCentrifugal Pump set for Capacity 10 HP 42 All as per item No 38here in above but for Centrifugal Pump set for Capacity 12.5 HP 43 All as per item No 38here in above but forCentrifugal Pump set for Capacity 20 HP 44 All as per item No 38here in above but for Centrifugal Pump set for Capacity 25 HP 45 All as per item No 38here in above but for Centrifugal Pump set for Capacity 30 HP 46 Disconnecting and removing unserviceable Gate Valve (ISI marked) 50mm dia and supply and fix, new Gun metal gate valve, 50mm dia, globe with iron wheel head, screwed both ends for GI Pipe 50 mm dia complete all as specified and directed. 47 Disconnecting and removing unserviceable CI Non Return valve (ISI marked) 50mm dia and Supply and fix, Cast iron non-return valve 50 mm dia, PN 1.6 rating, with flanged ends on both sides, complete fitted with GI pipe, including connected accessories and joining materials complete all as specified and as directed. 48 All as per Item No 46here in before but of 80 mm dia 49 All as per Item No 46here in before but of 100 mm dia 50 All as per Item No 46here in before but of 150 mm dia 51 Disconnecting and removing unserviceable Sluice Valve (ISI marked) of 80mm dia, and Supply and fix, Sluice Valve 80mm diaPN 1.6, Non raising type, brass spindle with hand wheel head, screwed both ends for GI Pipe 80 mm dia, including jointing material, complete all as specified and directed. 52 All as per Item No 50here in before but of 100mm dia 53 All as per Item No 50here in before but of 150mm dia 54 Disconnecting and removing unserviceable/ broken Spindle Brass along with the check nuts & gate from Sluice valve of 80mm dia, supply and fixing new Spindle with Brass Check nuts including polishing, machining, threading & necessary lathe work complete all as specified and as directed 55 All as per Item No 53here in before but for 100mm dia 56 All as per Item No 53here in before but for 150mm dia 57 Disconnecting and removing unserviceable CI Foot valve 50 mm dia of centrifugal pump sets, fixing CI Foot valve of 80mm dia with all fittings including flanges, leather washer, fasteners for fitting, necessary nut & bolts, washer, rubber packing / joining materials, complete all as specified and as directed. Note: Cast iron foot valves will be issued under Schedule B free for fixing. 58 All as per Item No 56 here in before but for 80 mm dia 59 All as per Item No 56 here in before but for 100 mm dia 60 Disconnecting and removing unserviceable Air Release valve of 80 mm dia andfixing Air Release valve double chamber of size 80 mm dia with all fittings, including jointing material completeall as specified and as directed.Note: Air release valves will be issued under Schedule B free for fixing. 61 Disconnecting and removing unserviceable butterfly valve of 100mm dia and fixing butterfly valve 100 mm diaPN 1.6 including jointing material complete all as specified and directed. Note: Butterfly valves will be issued under Schedule B free for fixing. 62 All as per Item No 60here in before butfor 150 mm dia 63 Disconnecting and removing unserviceable column pipe from open well / bore well of size 50mm medium grade and providing material and labour for column pipe GI 50mm dia medium grade of length 3 RM complete with both ends screwed and all as directed and specified. 64 All as per item No 62 here-in-above but of 150 mm dia pipe 65 Taking down unserviceable LT cable 35 Sqmm/70/95 Sqmm all as directed.Note : Excavation and earthwork where required will be measured and paid for separately. 66 Excavation in trenches not exceeding1.5mwideand notexceeding 1.5m in depth for taking out/for layingunder ground pipes etc and getting out in soft/loose soil complete all as specified and as directed. 67 Returning, filling in soils, including spreading, levelling, watering and well ramming in layers not exceeding 25 cms complete all as specified and as directed. 68 Removing excavated surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed. 69 Supply & Laying unreinforced precast concrete cable cover class LV type 1 plat size 250x150x40 mm laid in trenches as protection to cables all as directed 70 Material and labour for cable cushioning using riddled earth by sieving excavated soil as per IS-1255-1983 complete all as specified and as directed by Engineer-in-Charge.Note: Punned thickness will be considered for measurement and payment. 71 Supply & lay, connect, test and commissioning ofXLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (Heavy duty)1100 Volts grade with multi-stranded Aluminium conductor of following sizes 3.5 core 35 sqmm along with necessary endtermination complete.Note:Excavation, earthwork and cable protection works will be measured and paid for separately. 72 All as per item No 70here in above but cable of size 3.5 core 70 sqmm 73 All as per item No 70 here in above but cable of size 3.5 core 95 sqmm 74 Demolition of stone masonry / brick work / PCC block masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars etc., complete all as specified and as directed. 75 Material and labour for providing Pre-cast cement concrete block masonry with Grade C solid block, exceeding 10 cm in width, having minimum compressive strength of 40 Kg / Sq cm as per IS 2185 (Part-I) 2005 and set in CM 1:6 complete all as specified and as directed. 76 Material and labour for rendering 15mm thick on fair faces of brick work or concrete surface in CM 1:4 surface finished even and faircomplete all as specified and as directed.. 77 Material and labour for preparation of old painted steel and iron surfaces of GI/CI/DI pipe of any dia by applying one coat of synthetic enamel paint (first quality) matching with existing colours complete all as specified and as directed. 78 Supply and Fix in replacement of MS sheet cover of size 1 mtr x 1 mtr fabricated out of 3mm thick sheet with angle iron frame made out of 40mm x 40mm x 5mm and locking arrangement incl painting with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed . 79 Supply and Fix in replacement of MS sheet cover of size 90 cm x 90 cm fabricated out of 3mm thick sheet with angle iron frame made out of 40mm x 40mm x 5mm and locking arrangement incl painting with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed . 80 Supply and Fix in replacement Mild steel plates, plain or chequered, 5mm thick cut to shape and size to match with the existing duct of pump houses and painting the same with two coats of synthetic enamel paint over one coat of red oxide primer all as specified and directed by Engineer in charge 81 Supply and Fix DI specials such as bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch, Y junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs upto 150mm bore complete all as specified and as directed. 82 Supply and Fix in replacement 100 Watt LED flood light fittings integral type, with die cast housing with lens IP 66 protection complete all as specified. 83 Supply and Fix in replacement high efficient LED street light fitting of 45 W 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistantcomplete all as specified. 84 Disconnection & taking down unserviceable GI bracket of size 25 mm dia from buildings/poles and Material and labour for street light bracket made out of25 mm dia GI tubing medium gradeupto 1.5 mtr long including bending, welding ,drilling holes as required and fixing with flat iron clamps 50x 6 mm thick (02 Nos) with suitable nut, bolts and washers to steel tubular /concrete poles/buildings complete, including preparation of steel and iron surface and applying two coats of aluminium paint, first quality, over a coat of primer, etc complete, all as specified and as directed. 85 Disconnecting and removing the existing unserviceable starter panel and its connections and supply, install, testing and commissioning of new indoor starter panel for centrifugal pump set of capacity 20 HP- 02 Nos & 10 HP- 02 Nos, factory fabricated, CPRI approved, cubicle type, 2.00 mm thick CRCA sheet vermin proof with 3 phase and neutral Aluminium bus bar of current capacity 200A of suitable size, phase and neutral colour coded with heat shrinkable PVC sleeves, with necessary supports, angle iron frame work and stand, locking arrangements and painting with one coat of red oxide primer and two coats of powder coated paint, suitable size of panel control copper wiring, accessories fitted on suitable insulator all housed in suitable bus bar chamber and fixing of digital Voltmeter, Ammeter with built in selector switch, CTs of suitable ratio, and pilot indication lamps along with provision of necessary cable entry/exit boxes for all incoming and out going cables with suitable cable glands etc on existing PCC foundation complete all as specified and directed.The panel shall comprise of following :- (a) MCCB 4 Pole, TM Release, 415V AC, 50Hz, 60A, BREAKING CAPACITY of 30kA- 01 No(b)R,Y,B LED indication lamps - 03 Nos(c) Multi function meter LED display - 01 Nos(d) Suitable TP MCBs - 04 Nos(e) Suitable CTs - Set of 3(f) Star Delta starters - for 20 HP(02 Nos) & for 10 HP(02 Nos) (g) Thermal over load relay of suitable capacity - 04 Nos(h) Suitable power contactors(j) Red, Amber LED indication lamps - 04 Set(k) Suitable timers - 04 Nos Note :-The quoted rate shall be deemed to include for breaking of floors/walls etc including digging of trenches for removing of cables of loops and connecting to the new panel boards and making good the disturbed surfaces to match with the existing surfaces. 86 Disconnecting and removing the existing starter panel and its connections and supply, install, testing and commissioning of new indoor starter panel for centrifugal pump set of capacity 15 HP- 03 Nos, factory fabricated, CPRI approved, cubicle type, 2.00 mm thick CRCA sheet vermin proof with 3 phase and neutral Aluminium bus bar of current capacity 200A of suitable size, phase and neutral colour coded with heat shrinkable PVC sleeves, with necessary supports, angle iron frame work and stand, locking arrangements and painting with one coat of red oxide primer and two coats of powder coated paint, suitable size of panel control copper wiring, accessories fitted on suitable insulator all housed in suitable bus bar chamber and fixing of digital Voltmeter, Ammeter with built in selector switch, CTs of suitable ratio, and pilot indication lamps along with provision of necessary cable entry/exit boxes for all incoming and out going cables with suitable cable glands etc on existing PCC foundation complete all as specified and directed.The panel comprises with following :- (a) MCCB 4 Pole, TM Release, 415V AC, 50Hz, 125 A, breaking capacity of of 25 kA- 01 No(b)R,Y,B LED indication lamps - 03 Nos(c) Multi function meter LED display - 01 Nos(d) Suitable TP MCBs - 03 Nos(e) Suitable CTs - Set of 3(f) Star Delta starters - for 15 HP(03 Nos) (g) Thermal over load relay of suitable capacity - 03 Nos(h) Suitable power contactors(j) Red, Amber LED indication lamps - 03 Set(k) Suitable timers - 03 Nos Note :-(a)The quoted rate shall deemed to include for breaking of floors/walls etc including digging of trenches for removing of cables of loops and connecting to the new panel boards and making good the disturbed surfaces to match with the existing surfaces. 87 Disconnecting and removing the existing starter panel and its connections and supply, install, testing and commissioning of new indoor starter panel for centrifugal pump set of capacity 10 HP- 02 Nos, factory fabricated, CPRI approved, cubicle type, 2.00 mm thick CRCA sheet vermin proof with 3 phase and neutral Aluminium bus bar of current capacity 200A of suitable size, phase and neutral colour coded with heat shrinkable PVC sleeves, with necessary supports, angle iron frame work and stand, locking arrangements and painting with one coat of red oxide primer and two coats of powder coated paint, suitable size of panel control copper wiring, accessories fitted on suitable insulator all housed in suitable bus bar chamber and fixing of digital Voltmeter, Ammeter with built in selector switch, CTs of suitable ratio, and pilot indication lamps along with provision of necessary cable entry/exit boxes for all incoming and out going cables with suitable cable glands etc on existing PCC foundation complete all as specified and directed.The panel comprises with following :- (a) 100A 4P 25kA MCCB TM Release,415V AC, 50Hz - 01 No(b)R,Y,B LED indication lamps - 03 Nos(c) Multi function meter LED display - 01 Nos(d) Suitable TP MCBs - 02 Nos(e) Suitable CTs - Set of 3(f) Star Delta starters - for 10 HP(02 Nos) (g) Thermal over load relay of suitable capacity - 02 Nos(h) Suitable power contactors(j) Red, Amber LED indication lamps - 02 Set(k) Suitable timers - 02 Nos Note :-(a)The quoted rate shall deemed to include for breaking of floors/walls etc including digging of trenches for removing of cables of loops and connecting to the new panel boards and making good the disturbed surfaces to match with the existing surfaces. 88 Material and labour for disconnecting and de-coupling the centrifugal pump of 20-30 HP capacity from foundation after opening /cutting the rustednuts, bolts etc including transporting the pump to workshop for repair and opening the centrifugal pump, replacing unserviceable spare parts such as gland plate, gasket packing set, DE bearing, NDE bearing, impeller key, coupling key, CI Casing wearing (Neckring), CI interstage ring, CI stuffing box bush, coupling nut including remetling of pump shaft,turning, balancing and machining work and re-assembling the same in original position and re-installing at existing position after repair and providing new MS nuts, bolts, packing flange etcincluding testing complete all as specified and as directed. 89 Supply and Fix in replacement of CI Impeller suitable for existing model & size complete all as specified and as directed. 90 Supply and Fix in repair off load change over switch, 200 Amps,4 pole, 415 V, 50 Hz, fully compacted in 1.6mm thick CRCA sheet enclosure of suitable size and direct mounted & side operated type, manually operated, consisting of two sets of terminals for connecting two incoming supply sources alongwith all necessary accessories complete all as specified and as directed. 91 Dismantling the earth chamber including Excavation and removing unserviceable earthing materials alongwith earth electrodes from the existing unserviceable earth pits pertains to installations/ buildings and Material and labour for Earthing complete with copper plate electrode 600 x 600 x 3.15 mm thick buried directly in ground ( earth pit not less than 2.25 m deep below ground level with top edge of the plate not less than 1.5 m below the normal ground level connected with copper strip 20 x 3 mm thick by means of bolts, nuts, check nuts and excavation & earth work in any type of soil, removing surplus soil to a distance not exc 50 m, with and including PCC chamber in PCC (1:2:4), type B using (20 mm graded stone aggregate ), mild steel frame made out angel iron of size 40 mm x 40mm x 3mm thick duly painted with two coats of synthetic enamel paint with two coats of synthetic enamel paints over one coat of red oxide zinc chrome primer hinged with and including 6mm thicks CI cover with handle, watering arrangement with funnel internally secured with wire mesh with 20mm dia medium grade pipe for watering, 40mm dia light grade GI pipe for lead protection in and including alternate layer of charcoal dust and common salt complete all as shown in electrical plat no. 3 connected to earthing test point all as specified and indicated including testing on completion as directed Note:- The earth resistance shall be not less than 5Ω, in case of resistance beyond the specified limit, the contractor shall provide additional earthing in parallel with the existing without any additional cost. 92 Material and labour for earth continuity conductor of size 20x3 mm copper strip or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation complete all specified and directed.
Contract Date : 04 Feb, 2026   |   Contract Value : 19.28 Lakhs
BRR : 8672737 REPAIR/MAINT OF PUMP SETS, MOTORS, WATER FILTERATION PLANT, CHLORINE DOZING SYSTEM, RO PLANT, AND ITS ALLIED WORKS AT PROTHRAPUR FILTERATION PLANT, RWH, CHOULDHARI DAM,NTS, NAD MARCOS, PORT MOUNT UNDER AGE EM-II OF GE MINNIEBAY, SRI VIJAYA PURAM; 1 Supply, layig, testing and commissioning in replacement of ERW NB MS pipes of size 150mm dia, ISI marked grade 8 mm thick as per IS : 3589 grade 330 suitable for welded joints and flanged joints including fabricating tailor made as per site requirement including painting with two coats of anticorrosive paint complete all as specified ad as directed.Make : Jindal, Allied Pipes, after bailingout water from existing semi UG sump of Cap.150000 Gallons with Appx. 7 Mtr.depth at porthrapur filtration Plant and other places as directed by Engr-in-charge. 2 M&L in replacement for tyton joints of 200/350/400 mm dia using rubber gasket ISI marked suitable for spigot and socket pipes and fittings for CI / DI all as specified and directed. 3 Supply & fixing in replacement of Mechanical joint of size 250/350mm borewithbolts, nuts, washers for pipe line leakages complete all as specified and as directed by Engineer-in-Charge. 4 Supply & fixing in replacement of Mechanical joint of size 400mm borewithbolts, nuts, washers for pipe line leakages complete all as specified and as directed by Engineer-in-Charge. 5 M& L for spray painting with synthetic enamel paint on old painted surfaces of pumps,motors, sluice valve ,NRV & other machineries including necessary preparation of surfacesfor each job at Chouldari dam pump house, Porthrapur filteration plant, NTS Pump house including using white paint for letter writing of existing SM/MES No complete all as specified and as directed by Engineer-in-Charge. 6 M&L for attending repairing of pipeline of size 200 to 400 mm bore through caulking / welding execavation and earthwork in mud/soil by using labour to a length of 1 m approx (from chouldari to minniebay pump house) and depth upto 1 Mtr and forming bund with excavated Hard / soft soil to avoid sea/raw water entering into the working area including pumping/ bailing out water by using portable diesel engine driven pumpset complete all as directed and including the following:- (i) Cutting of CI/DI pipe of sixe upto 400/350/300/250/200 mm dia after through inspection for the damage incl bailing out water using portable pumpset. 7 Supply and laying in replacement submersible flat cable PVC insulated and screened PVC beddedgalvanised steel strip or wire armoured electric power cable (Heavy duty) LT UG cable with stranded copper conductor for 1100 volts grade of 10 sqmm 3 corein trenches or passing through pipe complete in all respects to the entire satisfaction of Engineer-in-Charge. 8 Supply and fixing in replacement of reducer eccentric type 200 x 150 mm heavy duty, pressure rating2A PN 16 bar, including nut bolts, washer andgaskete for suitable size complete all as specified and directed by Engineer-in-Charge. 9 Material and labour in repair, Composition, Supply & Installation of 4 inch thick ACP Box of size 10 feet x 3 feet with MS pipe structure fix inside with 3 mm Acrylic sheet with digitally printed 3m backlite Vinyl on HP Latex Printer, Display both side, LED modules complete upto 100 letters as specified size directed by Engineer-in-Charge with Andaman & Nicobar command and MES logo fixed with four nos of MS pipe Heavy duty 50 mm bore up to 6m height by nuts/bolts and welding as required at site, spray painting with two coat synthetic enamel paint comlete Mild Steel pipe including necessary excavation and PCC work for foundation complete all as specified and direced by Engineer-in-Charge 10 M&L for attending break down, execavation and earthwork in mud/soil by using earthmoving machinery (Hitachi)/labour to a length of 10 m approx (from chouldhari to Minniebay Pump House) and depth upto 3 Mtr and forming bund with excavated Hard/soft soil to avoid sea/raw water entering into the working area including pumping/bailing out water by using portable diesel engine driven pumpset complete all as directed and including the following :-(i) Cutting of CI/DI pipe of size upto 500/400/350/300 mm dia after thorough inspection for the damage incl bailing out water using portable pumpset.(ii) Taking out CI/DI pipe after removing from tyton joints at both ends with the help of Hitachi and keeping aside for further disposal.(iii) Transporting CI/DI pipe of size upto 500/400/350/300 mm dia to the site from Chouldhari dam or any area as directed by Engr-in-Charge, cutting the pipe into two pieces as per requirement and laying into the trenches using machinery.(iv) Jointing by using rubber tyton rings upto 500/400/350/300mm dia pipe to the corresponding socket and spigot ends of the existing pipeline after aligning the pipe line as per site condition, inserting the CI collar of size 500/400/350/300 mm dia complete all as directed.(v) CI/DI special will be measure separately in respective item 11 Note :- (i) The contractor shall provide team comprising of pipe fitter and an assistant for cutting and re-jointing with existing pipe line all as per direction of Engineer-in-charge. The cost for the above items including all type of tools and plants / any type of vehicle / earth moving plant / hitchi / JCB as required at site is deemed to be included in unit rate quoted for above items. (ii) The contractor shall take due care while executing the work (i.e non damage of electrical cable, telephone cable, water supply pipe line etc) during execution of work if any fault / cutting occurred shall carry out repair immediately and cost of the same shall deemed to be included in quoted rates. (iii) During execution of work if any liaison required for laying of pipe at site, from civil Administative department, local people gram panchayat, police station etc are the sole responsiblity for contractor. The contractor shall not claim and financial liabilities on this matter on bills. (iv) The cost of necessary encasing of pipe in culvert shall deemed to be included in this quoted rate all as specified and directed by Engr-in-Charge. 12 All as per Item No.10.00 above but depth above 3 Mtr all as directed by Engineer in ChargeNote : (i) The rate is deemed to include cost towards tools and plants and transportation required for attending the repair work. (ii) The rate deemed to inclusives of soil additional required to refilling/ making bunds to prevent sea water entering into the work place complete.(iii) The cost of pipes, specials, Tyton/lead joints shall be measured and paid seperatelyunder relevent item of this schedule. 13 M&L for detecting and repairing leakage in CI/DI pipe lines of size 250/200 mmbore, taking up unserviceable /serviceable CI/DI water main with spigot and socket ends (including fittings) of any type/grade and joints from trenches and layingnew CI/DI pipe lines of size 300 mm bore in trenches or placing on existion pillers /supports as directed to perform the following activities :-(a) Execution and earth work in soil / mud by using machinery/labour to suitable length (Appx 10 mtrs) and forming bund with excavated soil to avoid sea / row water entering into the working area including pumping/bailing out water by using portable desal engine driven pump set. (b) Cutting of CI / DI pipe of size 200 mm bore after through inspetion for the damaged pipe line including disconnecting / dismentling.(c ) Taking out CI/DI pipewith CI/DI specials after removing from joints/burning out joints and removing lead at both ends with the help of hydrolic crane other machinery and keeping aside fr further disposal.(d) Cutting of new pipe into pieces as per rquirement and laying using machinery.( e) Alinging the pipe line as per sie condition, in setting theCollar suitable for 200 mm CI/DI pipe.(f) Attending repair work within the minimum time frame/period as specified by Engr - in - charge. 14 Notes for the Itemsi) The unit rate is deemed to include cost of tools and plants and transprtation required for attending the repair work.ii)Supply only CI/DI pipe shall be measured & paid for seperately under relevant item of this schedule.iii) Extra soil required for refilling /making bunds to prevent water entering into the work place shall be deemed to include in the unit rate.iv) Specials / rubber or fiber/ lead joints shal be measured and paid for seperately under relevent items of this schedule.v) Old unsv CI/DI pipes, fittings, lead, nuts, bolts, washer, gaskets etc. shall become contractors property and necessary recovery as per schedule of credit shall be deducted from contractor.(vi) The contractor shall take due care while executing the work (i.e non damage of electrical cable, telephone cable, water supply pipe line etc) during execution of work if any fault / cutting occurred shall carry out repair immediately and cost of the same shall deemed to be included in quoted rates. (vii) During execution of work if any liaison required for laying of pipe at site, from civil Administative department, local people gram panchayat, police station etc are the sole responsiblity for contractor. The contractor shall not claim and financial liabilities on this matter on bills. 15 All as per item No:12.00 here-in - before but for CI/DI pipe line of size 80/100/150mm 16 M&L for attending of water supply complaints for any leakage/blockage in GI /CPVC/PPR pipe lines of size 20mm/25mm bore taking up serviceable / unserviceable GI water pipe lines all fitings/fixtures from trench including supply and laying GI / CPVC/PPR tubing 20mm/25mm bore up to 1 mtr length (max) including necessary cutting, threading and replacement of unserviceable GI/CPVC/PPR fittings such as GI/CPVC/PPR socket /Nipple/union socket, Tee, Tee reducer etc. of size 20mm/25mm including necessary excavation and earth work upto 1 mtr length to repair the leakage/clearing the blockage in the pipe line and testing on completion. (Replacement of unserviceable GI fittingssuch as GI socket /Nipple/union socket/Tee/Tee reducer etc. shall be measured and paid for separately under relevant items of this schedule here-in-after) 17 All as per item No 14.00 here-in- before but of size 40/50/80/100mm bore GI pipe line and -do- 18 All as per item No 14.00 here-in-before but in GI /CPVC pipe lines on wall/floor/roof of the bldg (20/25/40/50mm) 19 All as per item No 14.00 here-in-before but in GI /CPVC pipe lines on wall/floor/roof of the bldg. (80/100m) 20 Taking up or down old/chocked water tubing of CPVC pipes of size 20/25/50/80/100 mm bore with fittings from trenchs/walls cleaning for refixing in new or old position or credit to contractor all as specified and as directed. 21 Supply and fix in replacement of 20mm dia CPVC pipes SDR 11 including fittings on walls/ceilings/laying in trenches complete all as specified and as directed. 22 Supply and fix in replacement of 25mm dia CPVC pipes SDR 11 including fittings on walls/ceilings/laying in trenches complete all as specified and as directed. 23 Supply and fix in replacement of 50mm dia CPVC pipes SDR 11 including fittings on walls/ceilings/laying in trenches complete all as specified and as directed. 24 Supply and Fix in replacemet of CPVC Union suitable for 25 mm CPVC pipe complete all as specified and directed 25 Supply and Fix in replacement of CPVC Union suitable for 50 mm CPVC pipe complete all as specified and directed 26 Supply and Fix in replacement of CPVC ball valve suitable for 25 mm CPVC pipe complete all as specified and directed 27 Supply and Fixin replacement of CPVC ball valvesuitable for 50 mm CPVC pipe complete all as specified and directed 28 S&F in replacement tubes medium grade galvanized iron pipes of following size with all fittings laid in trenches/fixed on wall/on roof etc including taking down of old rusted pipe of as under:- 29 (a)20mm dia 30 (b)25mm dia 31 (c)40mm dia 32 (d)50mm dia 33 (e)80mm dia 34 (f)100mm dia 35 S&F 3- layer PP-R Polypropylene random copolymer) concea end pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches in following sizes:- 36 (a) 32 mm dia 37 (b) 40mm dia 38 (c) 50mm dia 39 (d) 90 mm dia 40 M&L for DI pipes with spigot and socket ends/flange type as required on site, Taking up unserviceable CI/DI Water Mains ( including fittings) with spigot and socket ends and lead joints from trench of any type/grade including burning out of joints and recovering lead complete all as specified and as directed by Engineer-in-Charge of the following sizes :-:-(i) The contractor shall take due care while executing the work (i.e non damage of electrical cable, telephone cable, water supply pipe line etc) during execution of work if any fault / cutting occurred shall carry out repair immediately and cost of the same shall deemed to be included in quoted rates. (ii) During execution of work if any liaison required for laying of pipe at site, from civil Administative department, local people gram panchayat, police station etc are the sole responsiblity for contractor. The contractor shall not claim and financial liabilities on this matter on bills. 41 (a) 100mm bore 42 (b) 150 mm bore 43 (c) 200mm bore 44 (d) 250 mm bore 45 (e) 350 mm bore 46 (f) 400 mm bore 47 M&L for Painting to GI / CI/DI water pipe line including Sluice Valves,valve chambers, NRV etcwith two coat of synthetic enamel paint of black colour/shade or approved colour duly preparing the existing painted surfacesto the entire satisfaction of Engineer in charge of following dia of pipes :- 48 (a) 80/100/150 mm Dia 49 (b) 200/250 mm Dia 50 (c) 350/400 mm Dia 51 S&F in repairs safety instruction/pump motor details display notice board for water supply installation made out of acrylic board in rectangle shape with heavy duty aluminium frame of size 0.5mtr x.75 mtr with details of pump/motor using letters as given and directed by Engineer-in-Charge and screwing the same on the wall properly complete all as specified and as directed by Engineer-in-Charge. 52 Material and labour for heavy duty rubberised Hose pipe dia of 350 mm with MS flange type in black colour, high quality synthetic rubber bend resistant to abrasion,high tensile synthetic textile cord, working pressure 25 bar all as per IS 13070-1991 specification including taking up unserviceable old existing pipe all as specified and directed by Engineer-in-charge. 53 Supply and fixing in replacement Gun Metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe fixed of the following sizes :- 54 (a) 20 mm bore 55 (b) 25 mm bore 56 (c) 40 mm bore 57 (d) 50 mm bore 58 (e) 80 mm bore 59 Supply and fix in replacement cast iron sluice valve ISI marked class PN 1.6 heavy duty ISI marked both ends flanged, suitable for following bore conforming to IS 14846 of 2000 duly with wheel operated handle with high tensile stainless steel spindle including nuts, bolts, washers etc of required size including taking out old existing unserviceable sluice valve and making arrangement for safe working complete all as specified and as directed by Engineer-in-Charge. 60 (a) 100mm bore 61 (b) 150mm bore 62 (c) 200/250 mm bore 63 (d) 350/400 mm dia bore 64 (e) 500mm dia bore 65 M&L for repairing and Servicing of Sluice valve by removing the nut and taking out spindle for turning in Lathe workshop replacement of necessary spare parts and refix at original position after service complete all as specified and directed for the following sizes:- 66 (a) 100/150/200/250 mm dia bore 67 (b) 350/400 mm dia bore 68 Supply and fix in replacement flangedNon return valve flap type, cast iron body, PN1.6,confirming with IS provision of 3mm thick rubber gasket on both sides of the flanges, bolts and nuts complete including dismantling of unserviceable valve all as directed of following sizes:- 69 (a) 100/150 mm dia bore 70 (b) 200/250 mm dia bore 71 Repairs to existing 100/150 mm bore Air release valve by remvoing the valve and repairing the same by replacing gaskes,nut,bolts, top cover and ball refixing the same, cast iron body, on both sides of the flanges, bolts and nuts complete all as specified and directed. 72 Supply and fix in replacement of air release valve suitable for 80/100 mm dia pipe all as specified and directed. 73 S&F in replacement, Cast Iron foot valve ball type of size 150mm, heavy duty confirming to relevant ISfixing with provision of new rubber flange gasket, nut, bolt, double washer, etc., complete including dismantling of unserviceable valve from UG sump all as specified and as directed. Make : Normax,Kirlosker or equivqlent. 74 S&F in replacement, Cast Iron foot valve ball type of size 200mm, heavy duty confirming to relevant ISfixing with provision of new rubber flange gasket, nut, bolt, double washer, etc., complete including dismantling of unserviceable valve from UG sump all as specified and as directed. Make : Normax,Kirlosker or equivqlent. 75 S&F in replacement, Cast Iron foot valve ball type of size 250mm, heavy duty confirming to relevant ISfixing with provision of new rubber flange gasket, nut, bolt, double washer, etc., complete including dismantling of unserviceable valve from UG sump all as specified and as directed. Make : Normax,Kirlosker or equivqlent. 76 S&F in replacement of Gun Metal Foot valve 50/80 mm bore complete all as specified and as directed by Engr-in-Charge. 77 S&F in replacement of Butter fly valve Flange type suitable for 200/250mm bore with rubber gaskets, nut and bolts of suitable size, ISI marked conforming to IS-13095 complete including dismantling of unserviceable valve all as directed. 78 S&F in replacement of Butter fly valve Flange type suitable for 150mm bore with rubber gaskets, nut and bolts of suitable size, ISI marked conforming to IS-13095 complete including dismantling of unserviceable valve all as directed. 79 S&F in replacement of CI/DI Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.)Tee pieces single branch.Y junction, double branch, cross (all sockets or socket and spigot or flanged) collars, caps and plugs upto 400 mm boreISI Marked all as specified and directed by Engr-in-Charge 80 S&F in replacement joint with rubber or fiber board gasket (flange joints) suitable for flanged pipes and fittingsof thefollowing sizes :- 81 (a)80mm bore 82 (b) 100mm bore 83 (c ) 150mm bore 84 S&F Gland packing 12.5mm/10mm dia / thickMake Champion / equivalent for sluice valve / pumps, leakage rectification. 85 Supply and fix nuts,bolts, washers for valves and pump sets of various grade as required. 86 Supply only TDS/chlorine test for pump house to check TDS valve as per directed. 87 Supply only Orthotodiline chemicalsolution for Chlorine checking as per directed. 88 S&F in replacement rubber (star) coupling of existing size for suitable 40HP/50HP/60/125/165/170HP pump set all as specified and directed at site by engr-in-charge. 89 M & L in replacement of MS coupling with rubber( spider type) L-276 or required on site of existingpump suitable for 60/165 /125/100 Hp pump sets complete all as specified and as directed. 90 S & F in replacement insulation rubber mat of size 1x2 mtr in black colour, 19 mm thick confirming to IS 15652/IE 61111 of suitable size all as specified and directed to the entire satisfaction of Engr-in-charge. 91 Repair/ Maint of masonry pit of existing size (internal) for sluice valves with sub PCC block wallstraight or curvedradius built in CM 1:6 PCC 1:3:6 in foundation, 15 mm thick plaster in CM 1:4 on internal faces of walls, 40 mm thick, PCC 1:2:4 in floors including valve pit cover made out of MS sheet 3 mm thick with angle iron 40x40x6 mm frame with fixing hinges, locking arrangements, hold fasts and handle etc duly painted with two coats of synthetic enamel paint over a coat of red oxide primer including necessary excavation & earth work complete all asincluding demolition of existing broken valve pit chamber complete in all respects to the entire satisfaction of Engr-in-Charge Note : MS sheet will be measured and paid seperately under relevant item of the schedule. 92 Material and labour for construction of block masonry valve pit of size 60 cm x 60 cm x 60 cm (internal dimensions) with one brick thick wall in cement mortar (1:4) on 100 mm thick PCC (1:4:8) type D2 (using 40 mm graded agrregate) as in foundation, 15 mm thick rendering in cement mortar (1:4) internally and externally upto 15 cm below ground level including, provision of valve pit cover made out of 3 mm thick MS sheet welded with 40 x 5 mm thick flat iron all round, on ISA 40 x 40 x 6 mm frame, fixed with hold fast 150 mm long, emebedded in PCC (1:2:4) type B1 (Block size 230 x 200 x 100 mm) with necessary hinges, handles, locking arrangement, including applying two coats of white wash on plastered surfaces and two coats of dituminious paint over a coat of red oxide primer on steel surfaces and necessary earth work in soft/ loose soil & demolition of old unserviceable valve chamber complete all as specified and as directed by Engineer-in-Charge. 93 Material and labour for construction of block masonry valve pit of size 90 cm x 90 cm x 90 cm (internal dimensions) with one brick thick wall in cement mortar (1:4) on 100 mm thick PCC (1:4:8) type D2 (using 40 mm graded agrregate) as in foundation, 15 mm thick rendering in cement mortar (1:4) internally and externally upto 15 cm below ground level including, provision of valve pit cover made out of 3 mm thick MS sheet welded with 40 x 5 mm thick flat iron all round, on ISA 40 x 40 x 6 mm frame, fixed with hold fast 150 mm long, emebedded in PCC (1:2:4) type B1 (Block size 230 x 200 x 100 mm) with necessary hinges, handles, locking arrangement, including applying two coats of white wash on plastered surfaces and two coats of dituminious paint over a coat of red oxide primer on steel surfaces and necessary earth work in soft/ loose soil & demolition of old unserviceable valve chamber complete all as specified and as directed by Engineer-in-Charge. 94 Excavating in trenches in soft / loose soil, n.exc 1.5m wide and n.exc 1.5m in depth: for foundation, etc. Or for shafts, wells, cessapits, manholes, pier holes, etc. n.exc10 Sq.m on plan and in.exc 1.5m in depth and getting out all as specified and directed by Engr-in-Charge 95 Excavating in trenches in hard / dense soil, n.exc 1.5m wide and n.exc 1.5m in depth: for foundation, etc. Or for shafts, wells, cessapits, manholes, pier holes, etc. n.exc10 Sq.m on plan and in.exc 1.5m in depth and getting out all as specified and directed by Engr-in-Charge 96 Returning, filling in, including spreading, levelling watering and well ramming in layers n.exc.25cm in any type of soil all as specified and as directed. 97 Removing excavated material to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above starting point in any type of soil getting out all as specified and as directed by engr-in-charge. 98 M & L for precast cement concrete 1:2:4 type B2 using 40 mm graded stone aggregates as in mass concrete/foundation/for supporting (encasing) of DI pipes of any size and in any position including plastering of surfaces complete all as specified and directed. 99 M & L for precast cement concrete1:3:6 type B1 using 20 mm graded stone aggregates as in mass concrete/foundation/for supporting (encasing) of DI pipes of any size and in any position including plastering of surfaces complete all as specified and directed. 100 M&L for testing of water samples and obtain the test result for the parametrsas per IS 10500 like TDS,Colour,odour,TSS,PH,coliform turbidity,etc by carrying physical,chemical,microbiology examiniationfrom any govt authoarised /NABL approved laboratary complete all as specified and as directed by Engr-in-Charge. Note :(i) Source/location of water samples shall be decided by the Engineer-In-Charge. (ii) Test test report shall be submitted by the contractor along with RAR/FB for payment of this item 101 M&L in replacement for MS sheet (3.15)mm thick) for valve chamber cover/cable duct cover with plates of Fe 410W, Gde E-250, quality -A(Plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment with riveted, bolted or welded attachment for locking arrangements complete including painting with two coat of synthetic enamel paint black colour/shade over a coat of red oxide primer complete all as specified and directed by Engineer - in - Charge. 102 S & F in replacement Fe410 W (Gde E-250) quality A for chamber ,RCC tank and heavy bracket framing ( Beam,tee, angle channel or flat section) including distance pieces, clests etc. complete including painting with two coat of synthetic enamel paint black colour/shade over a coat of red oxide primer complete all as specified and directed by Engineer - in - Charge. 103 M&L for fabrication of MS channel baseof existing size and grade made out of Steel channel MC75,MC100 &MC125 (As per existing dimensions) for pump and motor capacity 100 HP / 125 HP as mentioned against item including necessary cutting, welding, grinding etc., and fixing the same on newly provided PCC foundation, foundation bolt etc., as per manufacturer recommendations to ensure proper alingment of both pump and motor complete, carry out painting the complete base plate with two coat of synthetic enamel paint Black shade / colour over a coat of Red oxide primer complete all as specified and as directed by Engineer-in-charge. 104 Takng down old unservicable cable and Supply and Laying in replacement ofXLPE insulated, screened, PVC bedded, galvanised steel strip or wire unarmoured, electric power cables (heavyduty) with Copper conductor, 1100 volts Earthed, 3 Core, grade cross sectional area 25 sqmm as specified and directed. 105 S&F in replacement Fully automatic star-Delta starter suitable for 30/40/50/60HP Motor of centrifugal pump including voltmeter, Ammeter, Indicator, OL protector, SP preventer, relay if required on site complete with suitable factory made sheet enclosure of complete all as specified and as directed by engineer-in-charge. 106 S&F in replacement Fully automatic star-Delta starter suitable for 125/170HP Motor of centrifugal pump including voltmeter, Ammeter, Indicator, OL protector, SP preventer, relay if required on site complete with suitable factory made sheet enclosure of complete all as specified and as directed by engineer-in-charge. 107 S & F in repair for DOL startor of capacity upto 10 HP motor fully automatic type complete all as specified and as directed. 108 S & F in repair for DOL startor of capacity upto 20 HP motor fully automatic type complete all as specified and as directed. 109 Supply and fix in repalcement of Contactor 3 pole 415 volts upto 95 Ampsadjustable type(control voltage 415 as per existing model.) all as specified and directed. 110 Supply and fix in repalcement of Contactor 3 pole 415 volts for motor upto capacity 170 Amps (control voltage 415 as per existing model.) all as specified and directed. 111 Supply and fix in repalcement of over load relay for 30/40/50/60/125/170 Hp motor (control voltage 415 as per existing model.) all as specified and directed. 112 Supply and fix in repalcement of connector for motor of capacity upto 170 HP (control voltage 415 as per existing model.) all as specified and directed. 113 M & L for repair/maintenance ofback side cover of motor of capacity 30/40/50/ 60/125/170 HPas per existing model. all as specified and directed. 114 M & L for replacement of ball bearings of reduction gear box of lime/flash mixture and alum dosing unit at Prothrapur filteration plant complete all as specified and as directed. Make: SKF or as per site requirement as approved by GE 115 M & L for replacement of ball bearings of reduction gear box of clarifloculator bridge motor at Prothrapur filteration plant complete all as specified and as directed.Make: SKF or as per site requirement as approved by GE 116 M & L in replacement lugs upto 35 sqmm, copper conductor suitable for all 40HP/50HP/60HP as specified and directed by Engr in charger at site. 117 M&L for repair / maintenance to Decrin dozing pump including replacement of UNSV spare parts Rotor assy with bearings bracket, Pump tube,Injection check valve 3/8,Weighted suction line strainer 3/8,Connecting nut 3/8 with adopter,Ferrule 1/4 etc which will required on site and testing on completion for its smooth functioning to the entire satisfaction of Engr-in-Charge. 118 Supply, install, test and commissioning Altoch Gp Chlorine dosing system made up of non metallic thermoplastic with solution tank of capacity 100 Ltr to be fixed in 150/250/200mm bore CI/DI pipe line with following accessories:-(i) Dosing pump 230V, 50 Hz(ii) Agitator(iii) Water Intet / outlet regulator(iv) Overflow vent(v) Drain valve(vi) Fluid level controllerNote : The quoted rate includes all other accessories for operation of dosing system. 119 M&L Repair/Maint / Disconnecting electrical connection of pump set of capacity 1 HP to 7.5 HP and taking out complete assembly with electric motor and testing the complete and refixing with new, nuts, bolts & washers and fitting the sameafter the following repairs as mentioned here in after all as directed by Engr- in Charge. 120 Attending breakdown for pump/motor i.e minor repair (Changing of gand,nut bolt,connector etc) ,Panels/MCCB/Changeover Switch to check and locate / detect fault related to breakdown complete all as directed by Engineer-in-charge.Note:- (a) Spares will be measured and paid separately under relavant items. (b)The break down complaint should be attended within 2 hours with the intimation of Engr-in-charge or concern JE E/M by telephonically / verbally. 121 M&L Repair/Maint/servicing to Twin lobe Compressor unit single Phase,240 Volts 50 Hz, Type- SP-IH, Head 9 to 18 Meter,2800 RPM, used for back washing of filteration plant including oiling/greasing & provn of gland packing etc. and replacement of unserviceable parts for its smooth functioning to the entire satisfaction of Engr-in-Charge. 122 M&L Repair/Maint /Disconnecting electrical connection of Centrifugal pump set of capacity 50HP/60/125/165/170 HP and taking out complete assembly with electric motor, testing the complete and refixing with new, nuts, bolts,bearings, & washers and fitting the sameafter therepairs as mentioned here in after all as directed by Engr- in Charge. 123 S&F ,testing and commisioning in replacement of Alum/lime dosing pump reciprocating , mechanicaly actuated diaphragm type for dosing of liquid products.Pump capacity upto 1.5 HP, 440 Volts AC 1440 RPM motor/existing capacity as required on site of filteration plant complete with 100 ltrs per hour capacity or existing capacity of site inluding indicator and agitaor (1280 rpm) all as per direction of Engr-in-Charge 124 Dismantling and taking out the existing mono block / centrifugal/ Submersible type pump set, by disconnecting suction and delivery pipe lines of pump set, separate the motor from the pump, removing the burnt out winding from the slot cleaning the stator and rotor with CTC and smooth sand paper and rewinding the motor with suitable gauge of size with super enameled copper conductor and insulating by using class B insulation keeping for drying, connecting electricconnection, testing and commissioning to itssatisfactory of Engr-in-Charge complete all as directed for the following capacity :- 125 (a) 100/125 HP pump set. 126 (b) 165/170HP pump set. 127 Disconnecting and taking out Monoblock/Centrifugal/submersible motor pump capacity upto 7.5 HP capacity, pump set overhauling, greasing, cleaning and after completion aligning the motor in proper position and painting with one coat of anti corrosive paintincluding preparation of old surface including testing and commissioning for smooth running condition upto the satisfaction of Engr-in-Charge complete all as specified and as directed by Engr-in-Charge 128 Disconnecting and taking out Monoblock/Centrifugal/submersible motor pump capacity upto 10/15/20 HP capacity, pump set overhauling, greasing, cleaning and after completion aligning the motor in proper position and painting with one coat of anti corrosive paintincluding preparation of old surface including testing and commissioning for smooth running condition upto the satisfaction of Engr-in-Charge complete all as specified and as directed by Engr-in-Charge 129 Disconnecting and taking out Monoblock/Centrifugal/submersible motor pump capacity upto 30/40 HP capacity, pump set overhauling, greasing, cleaning and after completion aligning the motor in proper position and painting with one coat of anti corrosive paintincluding preparation of old surface including testing and commissioning for smooth running condition upto the satisfaction of Engr-in-Charge complete all as specified and as directed by Engr-in-Charge 130 Disconnecting and taking out Monoblock/Centrifugal/submersible motor pump capacity upto 50/60 HP capacity, pump set overhauling, greasing, cleaning and after completion aligning the motor in proper position and painting with one coat of anti corrosive paintincluding preparation of old surface including testing and commissioning for smooth running condition upto the satisfaction of Engr-in-Charge complete all as specified and as directed by Engr-in-Charge 131 Dismantling and taking out the existing mono block / centrifugal/ submersible type pump set of Capacity Upto 7.5 HP Pump set, by disconnecting suction and delivery pipe linesof pump set , separatethe motor from the pump, removing the burnt out winding from the slot cleaning the stator and rotor with CTC and smooth sand paper and rewinding the motor with suitable gauge of size with super enameled copper conductor and insulating by using class B insulation keeping for drying, connecting electricconnection, testing and commissioning upto the satisfaction of Engr-in-Charge complete all as directed. 132 Dismantling and taking out the existing mono block / centrifugal/ submersible type pump set of Capacity 1015/20 HP Pump set, by disconnecting suction and delivery pipe linesof pump set , separatethe motor from the pump, removing the burnt out winding from the slot cleaning the stator and rotor with CTC and smooth sand paper and rewinding the motor with suitable gauge of size with super enameled copper conductor and insulating by using class B insulation keeping for drying, connecting electricconnection, testing and commissioning upto the satisfaction of Engr-in-Charge complete all as directed. 133 Dismantling and taking out the existing mono block / centrifugal/ submersible type pump set of Capacity 30/40 HP Pump set, by disconnecting suction and delivery pipe linesof pump set , separatethe motor from the pump, removing the burnt out winding from the slot cleaning the stator and rotor with CTC and smooth sand paper and rewinding the motor with suitable gauge of size with super enameled copper conductor and insulating by using class B insulation keeping for drying, connecting electricconnection, testing and commissioning upto the satisfaction of Engr-in-Charge complete all as directed. 134 Dismantling and taking out the existing mono block / centrifugal/ submersible type pump set of Capacity 50/60 HP Pump set, by disconnecting suction and delivery pipe linesof pump set , separatethe motor from the pump, removing the burnt out winding from the slot cleaning the stator and rotor with CTC and smooth sand paper and rewinding the motor with suitable gauge of size with super enameled copper conductor and insulating by using class B insulation keeping for drying, connecting electricconnection, testing and commissioning upto the satisfaction of Engr-in-Charge complete all as directed. 135 M&L Graphite gland packing, suitable for sluice valves or pump sets, fixed in position including taking down unserviceable gland packing as per site requirement etc complete all as specified and as directed by Engineer-in-Charge. 136 Supply and fix in replacement of pressure gauge suitable for 125HP/100HP pump of pressure 0-150 Kg/Sq CM rating for suction pipe/ Discharge pipe complete with connected pipe and stop cock of suitable size complete all as specified and as directed by Engineer-in-Charge. 137 Supply and fix in replacement ofpressure gauge suitable for 165HP/170HP pump of pressure 0-250 Kg/Sq CM rating for suction pipe/ Discharge pipe complete with connected pipe and stop cock of suitable size complete all as specified and as directed by Engineer-in-Charge. 138 Supply only 125HP/165HP/132KWpump impellor Gun metal model No. UP 150/45- 29 part , impellor part code No. 15900 complete all as specified and as directed by Engineer-in-Charge. 139 M&L for taking out existing centrifugal pump of capacity 170/ 165 Hp for servicing ( as per manufacturer instructions) by disconnecting motor and pump set, pipe line and removing of all parts like bearing, bushes, impeller, shaft etc cleaning all rusted surfaces and scales formed inside/out side pumpset etc cleaning, oiling, greasing at proper places and re-fixing with oil paper packingin position, duly aligned with motor with all serviceable partsincluding painting with one coat of anti corrosive paint over red oxide primer and writing MES /SM No and testing and commissioningcomplete all as specified and as directed by Engineer-in-Charge.Notes: i) Item requires replacement if found unserviceable then the same be replaced & measured and paid separately.ii) Spares will be measured and paid seperately. 140 M&L for taking out existing centrifugal pump of capacity 125/ 100 Hp for servicing ( as per manufacturer instructions) by disconnecting motor and pump set, pipe line and removing of all parts like bearing, bushes, impeller, shaft etc cleaning all rusted surfaces and scales formed inside/out side pumpset etc cleaning, oiling, greasing at proper places and re-fixing with oil paper packingin position, duly aligned with motor with all serviceable partsincluding painting with one coat of anti corrosive paint over red oxide primer and writing MES /SM No and testing and commissioningcomplete all as specified and as directed by Engineer-in-Charge.Notes: i) Item requires replacement if found unserviceable then the same be replaced & measured and paid separately.ii) Spares will be measured and paid seperately. 141 M&L for Cleaning of RCC Semi underground drainage sump of appx size 50MtrX40Mtr and depth appx 6 Mtr situated by emptying the reservoirs, taking down the scale / sludge /mud / algae formed by JCB or manually including and other foreign materials got deposited on side of walls and bottom of the tanks by scrapping and brushing with wire brush, cleaning with pressure pump, washing with bleaching powder slurry and allowing to dry and then washing and cleaning the tank with fresh water including applying two coat of white wash on internal surface of reservoirs/sumps and written details on tanks like date of cleaning, capacity of tanks etc on the out side of the tankwith synthetic enamel paint with letter size 20cm high, 10cm width in white colour, over a black background of size 120 x 80cm all as specified and directed by Engr-in-Charge. 142 Suppy, installing, testing and commissioning 10 HP horizontal submersible Pump set at rated voltage 415V, 3 Phase 50Hz AC suppy , discharge @ 32 LPS at 30 mtr head,size 100x100mm, supply and installation complete including 60 Metre long submersible water proof 10 Sqmm 3 core cable,submersible pump shall be protected with metal cageing complete all as specified and directed by Engineer-in Charge.Make : Kirloskar/Crompton Greaves or equivalent.Model:- KOS-1030+ equivalent model in Greaves or equivalent. 143 Supply only stainless steel shaft as per sample for pumpset of capacity 170/165 HP complete all as specified and as directed by Engineer-in-Charge. 144 Supply only stainless steel shaft as per samplefor pumpset of capacity 125/100 HP complete all as specified and as directed by Engineer-in-Charge. 145 Supply only in replacement shaft sleeves of model No-UP150/45 with check nuts (Br) for 170/ 165 HP pump set complete all as specified and as directed by Engineer-in-Charge. 146 Supply only in replacement shaft shaft sleeves of with check nuts (Br) for 125/100 HP pump setModel DSM 125/40 complete all as specified and as directed by Engineer-in-Charge. 147 M & L inreplacement of old connection of Alum/ Lime dosing and providing new connection with CPVC pipe of dia 25mm /50mm and CPVC ball vale,SS bucket for lime doser as required on site,painting of old lime doser iron part , with cutting of wall/PCC which is required,plastering of broken part if required and two coatpaint with distemper of alum/lime dosing plant of existing colour all as specified and directed by Engineer-in-Charge. 148 Supply only ball bearingfor centrifugal pump of capacity 100/125/165/170 HP complete all as specified and as directed by Engineer-in-Charge. 149 S&F in repair MCCB 4 Pole, 415 V,250 Amps with breaking capacity 36 KA.Adjustable type. complete all as directed. 150 M&L to carry out periodical repair / maint of RO filtration plant of capacity 1000 ltrs per hour for its smooth functioning comprising the following equipments / plants including replacement of filter media, carbon media, membrane and micro filter etc including cleaning of 04 Nos PVC service tanks of 5000 ltr capacity each, and testing on completion for leakage to the entire satisfaction of Engr-in-Charge all as specified and directed Note:- The cost of parts / items to be replaced shall be measured and paid for separately under relevant items of this schedule here-in-after as supply only and cost of fixing charges including replacement of small parts such as screws, nut bolt and washers etc., are deemed to be included in this item 151 M& Lfor repair and topup different size offilter mediafor capacity 1000 LPH RO plant operating pressure 3.0 Kg/cm2 or suitable for site requirement complete all as specified and as directed by Engr-in-Charge 152 Supply & fixing,testing in replacement for different size of filters suitable for site requirement of capacity 1000 LPHcomplete all as specified and as directed by Engr-in-Charge 153 Supply and fixing replacement Membraneof size 2x500 of capacity 1000 ltrs/hr as per existing filter in RO Plant along with rubber ring complete complete all as specified and as directed by Engr-in-Charge
Contract Date : 19 Jan, 2026   |   Contract Value : 47.63 Lakhs
BRR : 6656599 Tender For Repair And Maintenance To Central Ac Plant Under Ge (Af) Jamnagar No 01. ; 1 Comprehensive maintenance including servicing of 9.01 KW capacity VRF based air conditioning system with connected indoor and outdoor units detail as under installed under GE(AF) Jamnagar for complete contract period detail as under all as specified and directed by Engr-in-charge.Out door unit 12 TR capacity VRF unit of Make -Daikin, Model No - RXYQ12TRY69Indoor unit :- Make-Daikina) Model no - FXAQ40PVE6, Sr No- E000894b) Model no - FXAQ40PVE6, Sr No- E000895c) Model no - FXAQ40PVE6, Sr No- E000891d) Model no - FXAQ40PVE6, Sr No- E000900e) Model no - FXAQ40PVE6, Sr No- E000828f) Model no - FXAQ40PVE6, Sr No- E000835g) Model no - FXAQ40PVE6, Sr No- E000888h) Model no - FXAQ40PVE6, Sr No- E000893j) Model no - FXAQ40PVE6, Sr No- E000538k) Model no - FXAQ32PVE6, Sr No- E000887 2 All as per item No 1 butOut door unit9.01 KW capacity VRF unit with 05 No Indoor unit of Make -Daikin, Model No - RXYQ12TRY69 Indoor unit :- Make-Daikina) Model no - FXAQ50PVE6, Sr No - E001464b) Model no - FXAQ50PVE6, Sr No - E001486c) Model no - FXAQ32PVE6, Sr No - E000541d) Model no - FXAQ32PVE6, Sr No - E000492e) Model no - FXAQ32PVE6, Sr No - E000537 3 All as per item No 1 butOut door unit9.01 KW capacity VRF unit with 04 No Indoor unit of Make -Daikin, Model No - RXYQ12TRY69. Indoor unit :- Make Daikin a) Model no - FXAQ40PVE6, Sr No - E000829b) Model no - FXAQ40PVE6, Sr No - E006896c) Model no - FXAQ63PVE6, Sr No - E001874d) Model no - FXAQ32PVE6, Sr No - E000544 4 All as per Item No 1 above but 7.29 KW capacity VRF unit of Make Daikin, Model No - RXYQ10TRY69,with 04 Nosindoor unit.(1) Indoor unit :- Make Daikina) Model no - FXAQ50PVE6, Sr No - E001606b) Model no - FXAQ50PVE6, Sr No - E001601c) Model no - FXAQ50PVE6, Sr No - E001873d) Model no - FXAQ63PVE6, Sr No - E001491(2) Indoor unit :- Make Daikin(a) Model no - FXAQ63PVE6, Sr No - E001875 (b) Model no - FXAQ50PVE6, Sr No - E001482(c) Model no - FXAQ50PVE6, Sr No - E001607(d) Model no - FXAQ50PVE6, Sr No - E001466 5 All as per Item No 1 above but 7.29 KW capacity VRF unit of Make Daikin, Model No - RXYQ10TRY69,with 05 Nosindoor unit.(1) Indoor unit :- Make Daikina) Model no - FXAQ40PVE6, Sr No - E000899b) Model no - FXAQ40PVE6, Sr No - E004325c) Model no - FXAQ40PVE6, Sr No - E004343d) Model no - FXAQ63PVE6, Sr No - E001785e) Model no - FXAQ63PVE6, Sr No - E001904(2)Indoor unit :- Make Daikina) Model no - FXAQ50PVE6, Sr No - E001599b) Model no - FXAQ50PVE6, Sr No - E001603c) Model no - FXAQ63PVE6, Sr No - E001779d) Model no - FXAQ63PVE6, Sr No - E001756e) Model no - FXAQ63PVE6, Sr No - E001764 6 All as per Item No 1 hereinbefore but 50 KW capacity VRV unitof Make Hitachi, Model no - RAS18FSXNK, Sr. No. 190G06595 -02 Nos with following indoor unit.(1) Indoor unit :- Cap-4.1 TR, Make Hitachia) Model no - RCL-5.0 FSKDNQ, Sr No - QCK7PT251015 b) Model no - RCL-5.0 FSKDNQ, Sr No - QCK7PT291016c) Model no - RCL-5.0 FSKDNQ, Sr No - QCK7PT25100Wd) Model no - RCL-5.0 FSKDNQ, Sr No - QCK7PT25100V (2)Indoor unit :- Cap-4.1 TR, Make Hitachia) Model no - RCL-5.0 FSKDNQ, Sr No - QCK7PT391054b) Model no - RCL-5.0 FSKDNQ, Sr No - QCK7PT391057c) Model no - RCL-5.0 FSKDNQ, Sr No - QCK7PT291014d) Model no - RCL-5.0 FSKDNQ, Sr No - QCK7PT391056 7 Note for Sr No 1 to 6: - Comprehensive / Preventive maintenance of VRF based air conditioning shall be carried out as per manufacturer standard check listand not less then six months interval from last maintenance and carried out onetimes during contract period and shall be measured one times, Contractor shall also be responsible to rectify any defect during break down without any extra cost during contract period complete all as directed by Engineer-in-Charge.(a) Testing / Checking of compressor for its proper functioning and rectification of minor defect if any.(b) Testing / Checking of control switch such as pressure cut outs, water flow switch, temperature sensor for proper function.(c) Testing / Checking of PCBs of the Indoor unit & Outdoor unit for its proper functioning and rectification of minor defects if any.(e) Testing / Checking of Cooling coil for leakage and Rectification of leakage by brazing including cleaning of Cooling coil. 8 (f) Testing / Checking & servicing of blower fan motor and rectification of minor defect if any.(g) Testing / Checking of all electrical connection and control wiring tighting of electrical connection and rectification of minor defect if any complete.(h) Testing / Checking & servicing of condenser fan motor and rectification of minor defect if any.(j) Testing / Checking of condenser coil for leakage and Rectification of leakage by brezing including cleaning of condenser coil.(k) Testing / Checking of refrigerant pipe for leakage and Rectification of leakage by brezing including cleaning of refrigerant pipe.(l) Cleaning of entire indoor & outdoor unit for removing all dirt dust, grease etc.(m) Contractor shall also be responsible to rectify any defect and maintain plant in running condition within 24 hours during break down, without any extra cost to govt during contract period. Failure to repair will attract penalty of @1000/per day, decision of GE in this regard final and binding 9 (n) (i) All defective spare parts & compressor etc if found unserviceable will be measured & paid separately as supply only under respective items of This BOQ, any other item not mentioned in BOQ if required will be provided and quoted rates for the same is included in rates of comprehensive maintenance .(ii) Topping of refrigerant gas will be measured & paid separately.(iii) The rates quoted by the tenderer shall be deemed to include for any minor repair, which are obviously and fairly, intended which may not have been included in these documents, but which are essential for the execution and entire completion of works.The decision of the Engr-in-charge as to what constitutes Minor details of the construction’ shall be final and binding.(iv) Comprehensive / Preventive maintenance including servicing of VRF unit, & repairing the VRF unit during breakdown / emergency shall be carried out. 10 Note for Item No 1 to 9 :- (i) Labour charges for, taking out old and supply new spares,T&P and Misc charges, items to be deemed to be included in the quoted rate for Comprehensive maintenance i.e. item No 1 to 6. (ii) Make of spare part shall be as recommended by the OEM and the same shall be used only after approval by the GE.(iii) Unserviceable parts shall be property of contractor as per credit schedule 11 Supply onlyinverter compressor suitable for 9.01 KW capacity VRF type AC unit (Make Daikin, Model no - RXYQ12TRY69) with base frame & electrical Phase reversal protection comprising following JOB:-(i) Charging of nitrogen Gas inunit & complete system at 300 psi pressure and checking of any dropping of pressure / leakage up to 72 Hrs after replacement of compressor & rectification of leakage if any.(ii) Vaccumisation of complete system for minimum 2 days for dropping of vacuum pressure& rectification of leakage if any. (iii) Charging of complete system with R410 / R407 gas for maintaining the system pressure up to HP - 175 psi & LP - 65 psi.(iv) Measure the inlet and outdoor temperature of package unit. (v) Testing & commissioning of compressor after completion. 12 Supply only of inverter compressor suitable for 7.29 KW capacity VRF type AC unit (Make Daikin, Model no - RXYQ10TRY69) with base frame & electrical Phase reversal protection comprising following JOB:-(i) Charging of nitrogen Gas inunit & complete system at 300 psi pressure and checking of any dropping of pressure / leakage up to 72 Hrs after replacement of compressor & rectification of leakage if any.(ii) Vaccumisation of complete system for minimum 2 days for dropping of vacuum pressure& rectification of leakage if any. (iii) Charging of complete system with R410 / R407 gas for maintaining the system pressure up to HP - 175 psi & LP - 65 psi.(iv) Measure the inlet and outdoor temperature of package unit. (v) Testing & commissioning of compressor and system to satisfactorycompletion. 13 Material and labour for maintenance of VRF air conditioner of 9.01/ 7.29/50 KW capacity, VRF type unit with replacement of old/unsv spare parts mentionedas under or as per manufacturer instructions including testing on load complete all as specified and as directed by Engr-in-chargeNote:- Make of VRF unit is Blue star, Hitachi & Daikin therefore spare part provided in the work shall be of of authorised spares as approved by the OEM. 14 Supply only main control PCBof indoor Unit of VRF type AC unitcomplete all as specified and as directed. 15 Supply only power PCB for indoor unit of VRF AC complete all as specified and as directed. 16 Supply only pump to indoor unit of VRF AC unit complete all as specified and as directed. 17 Supply only hiwall controller to indoor unit of VRF AC complete all as specified and as directed. 18 Supply only HP/LP sensor to indoor unit of VRF AC complete all as specified and as directed. 19 Supply only sensors(Liquid, gas temp, room temp,supply temp) to indoor unit of VRF AC complete all as specified and as directed. 20 Supply only SMPS Board to indoor unit of VRF AC complete all as specified and as directed. 21 Supply only Over Voltage PCB to outdoor unit of VRF AC complete all as specified and as directed. 22 Supply only HP Switch to outdoor unit of VRF AC complete all as specified and as directed. 23 Supply only motor to outdoor unit of VRF AC of any capacitycomplete all as specified and as directed. 24 Supply only main power PCB of outdoor unit of VRF AC of any capacity complete all as specified and as directed. 25 Supply only master controller PCB of outdoor unit VRF AC of any capacity complete all as specified and as directed. 26 Supply only capacitor board of outdoor unit VRF AC of any capacity complete all as specified and as directed. 27 Supply only noise filter board of outdoor unit VRF AC of any capacity complete all as specified and as directed. 28 Supply only sensors (Liquid temp HeX 1&2, Gas temp HeX1&2) of outdoor unit VRF AC of any capacity complete all as specified and as directed. 29 Supply only Solenoid valve of outdoor unit of VRF AC of any capacity complete all as specified and as directed. 30 Supply only Fan Blade of outdoor unit of VRF AC of any capacity complete all as specified and as directed. 31 Supply onlyPCB (master controller card) suitable for cassette type AC forof outdoor & indoor (set) unit of any capacity (upto 6 TR) complete all as specified and as directed. 32 M&L for descaling of complete copper condenser pipe of centralAC Plant Air condenser unit, (34 TR) Make : Bluestar.circulating suitable descaling compound / solution in--to the tube with pump, and running the pump continuously till all the scale from tube are removed including removing side covers of condenser and cleaning thecopper tubes by means of nylon brushes till the complete scaling is removed and refixing of covers including replacement of rubber gasket and refixing pipe connection etc. all as specified and directed to complete satisfaction of Engineer-in-charge. 33 M&L for descaling of complete copper condenser pipe of water cooled central type AC plants (30 TR ) capacities by circulating suitable descaling compound / solution into the tube with pump, and running the pump continuously till all the scale from tube are removed including removing side covers of condenser and cleaning the copper tubes by means of nylon brushes till the complete scaling is removed and refixing of covers including replacement of rubber gasket and refixing pipe connection etc. all as specified and directed to complete satisfaction of Engineer-in-charge. 34 M&L for descaling of complete copper condenser pipe of centralAC Plant Air condenser unit, (22 TR) Make : Bluestar.circulating suitable descaling compound / solution in--to the tube with pump, and running the pump continuously till all the scale from tube are removed including removing side covers of condenser and cleaning thecopper tubes by means of nylon brushes till the complete scaling is removed and refixing of covers including replacement of rubber gasket and refixing pipe connection etc. all as specified and directed to complete satisfaction of Engineer-in-charge. 35 Comprehensive maintenanceincluding servicing of AHU shall be carried out as per manufacturer standard check list and detailed as under all as directed by Engineer-in-Charge.(a) Testing / Checking & servicing of blower fan motor and rectification of minor defect if any.(b) Testing / Checking of blower fan blade for proper functioning.(c) Cleaning of cooling coil of AHU unit with pressurised water and then testing/ checking of Cooling coil for leakage and rectification of leakage by brazing including.(d) Testing / Checking of all electrical connection and control wiring tighting of electrical connection and rectification of minor defect if any complete.(e) Testing / Checking and Cleaning the moisture drain pipe.(f) Cleaning of entire AHU unit for removing all dirt dust, grease etc Contractor shall also be responsible to rectify any defect and maintain plant in running condition within 24 hours during break down, without any extra cost to govt during contract period. Failure to repair will attract penalty of @1000/per day, decision of GE in this regard final and bindingNote: Comprehensive / Preventive maintenance of AHU shall be carried out as per manufacturer standard check listand not less then six months interval from last maintenance and carried out onetimes during contract period and shall be measured one times, Contractor shall also be responsible to rectify any defect during break down without any extra cost during contract period complete all as directed by Engineer-in-Charge. 36 AHU unit 51 TR, 14500 CFM capacity, Make -Zeco Aircon Ltd 37 AHU unit 12 TR, 4500 CFM capacity, Make -Zeco Aircon Ltd 38 AHU unit 13 TR, 5500 CFM capacity, Make -Zeco Aircon Ltd 39 AHU unit 60 TR, 27700 CFM capacity, Make -Zeco Aircon Ltd 40 Supply, installation, testing and commissioning of hot water generator heating coil of capacity 25KW, fixed in repair complete all as specified and as directed. 41 Supply, installation, testing and commissioning of hot water generator heating coil of capacity05 KW, fixed in repair complete all as specified and as directed. 42 Comprehensive maintenanceincluding servicing of industrial dehumidifier shall be carried out as per manufacturer standard check list and detailed as under all as directed by Engineer-in-Charge.(a) Testing / Checking of Ecordy desicant honeycomb rotor/bed mounted on a horizontal fixed shaft arrangement and rectification of minor defect if any.(b) Testing / Checking of all electrical connection and control wiring tighting of electrical connection and rectification of minor defect if any complete.(c) Cleaning of inlet pre filter EU-4 synthetic non woven media filter with pressurised water. (d) Testing / checking of serviceability of Thermostat and rectification of minor defect if any.(f) Testing / Checking of Electrical heater bank or steam coil with electric heater for steam reactivation and rectification of minor defect if any complete.(g) Testing / Checking of Regeneration fan ang regeneration fan motor and rectification of minor defect if any complete.(e) Cleaning of entire unit for removing all dirt dust, grease etc Note :- Comprehensive / Preventive maintenance of industrial dehumidifier shall be carried out as per manufacturer standard check listand not less then six months interval from last maintenance and carried out onetimes during contract period and shall be measured one times, Contractor shall also be responsible to rectify any defect during break down without any extra cost during contract period complete all as directed by Engineer-in-Charge. 43 Dehumifier unit 3000 CMH capacity, Make- Bry Air 44 Dehumifier unit 2500 CMH capacity, Make- Bry Air 45 Supply only master controller card (PCB) suitable for outdoor unit Dehumidifier of capacity upto 3000 CMH, Model F113000 complete all as specified and as directed. 46 Supply only master controller card (PCB) suitable for outdoor unit Dehumidifier of capacity 1500 CMH, SOP 330 complete all as specified and as directed. 47 Supply only display unit suitable for Dehumidifier of capacity 3000CMH, Model No F113000 complete all as specified and as directed by Engr in Charge 48 Supply only V belts of size A-24 of blower motorof AC plant any type all as directed by the Engineer-in-Charge.Make : Fenner / Dunlop / JK. 49 Supply only V belts of size A-34/38 of AHU motorof AC plant any type all as directed by the Engineer-in-Charge.Make : Fenner / Dunlop / JK. 50 Supply only V belts of size B-56 of AHU motorof AC plant any type all as directed by the Engineer-in-Charge.Make : Fenner / Dunlop / JK. 51 Supply only V belts of size B-100/112 of AHU motorof AC plant any type all as directed by the Engineer-in-Charge.Make : Fenner / Dunlop / JK. 52 supply onlyOil/HP/LPpressure sensor Probe suitable for reciprocating Chiller unit of 30 TR central AC plant all as directed by the Engineer-in-Charge.Make:- Voltas Model : 09066 or equivalent make approved by The GE. 53 Supply only water differential pressure cut out switch MP-55 for compressor of central type AC plant of any capacity all as directed by the Engineer-in-Charge.Make : INDFOSS / DANFOSS/ HONEYWELL. 54 Supply only Single phase preventer relay for precision Air condition unit Make :- Minilec , Model No :- S2 VMR 6 or equivalent of make L&T / BHARATIA CUTTLER HAMMER / C&S 55 Supply only compressor over load protection type 3RP15761NP30 , starting time range 3-60 sec rated voltage :- 200-240V, 50HZ including connecting complete.Make:- SIEMENS / L&T / BHARATIA CUTTLER HAMMER / C&S 56 Supply only Blower timer type Micron Electronic Timer , including connecting complete.Make:- SIEMENS - Cat No :- 20SDTO or L&T / BHARATIA CUTTLER HAMMER / C&S 57 Supply onlyBlower over load protection type MN-2 SS01212 , rated voltage :- 200-500V, 50HZ, 2A ,AC-15, Maximum fuse 6A including connecting complete.Make:- SIEMENS / L&T / BHARATIA CUTTLER HAMMER / C&S 58 Supply only2 pole front mounted add on Auxiliary contact block type MNX -A2 for power contactor, 1 NO & 1 NC contactincluding connecting complete, all as specified & directed by Engg-in-charge.Make:- SIEMENS / L&T / BHARATIA CUTTLER HAMMER / C&S 59 Supply only 4 pole front mounted add on Auxiliary contact block type MNX -A1 for power contactor, 10 Amp capacity, 415 Vincluding connecting complete all as specified & directed by Engg-in-charge.Make:- SIEMENS / L&T / BHARATIA CUTTLER HAMMER / C&S 60 Supply only 3 pole power contactor 25 A, 415 V, coil voltage 230 V including connecting complete all as specified & directed by Engg-in-charge.Make:- L&T type MNX 25 or equivalent of make SIEMENS // BHARATIA CUTTLER HAMMER / C&S 61 Supply only 4 pole power contactor 18 A, 415 V, coil voltage 230 V including connecting complete all as specified & directed by Engg-in-charge.Make:- L&T type MCX 01 or equivalent of make SIEMENS // BHARATIA CUTTLER HAMMER / C&S 62 Supply only 3 pole power contactor 12 A, 415 V, coil voltage 230 V including connecting complete all as specified & directed by Engg-in-charge.Make:- L&T type MNX 12 or equivalent of make SIEMENS // BHARATIA CUTTLER HAMMER / C&S 63 Supply only 3 pole power contactor 32 A, 415 V, coil voltage 230 V including connecting complete.Make:- L&T type MNX 32 or equivalent of make SIEMENS // BHARATIA CUTTLER HAMMER / C&S 64 Supply only 3 pole power contactor 45 A, 415 V, coil voltage 230 V with including connecting complete.Make SIEMENS type 3TF4602-0A or equivalent of make L&T / BHARATIA CUTTLER HAMMER / C&S 65 Supply only 4 pole power contactor 175 Amp AC 1 and 140 Amp AC 3, suitable for 75 KW/100HP compressor , 415 V, coil voltage 230 V with including connecting complete.Make SIEMENS / L&T / BHARATIA CUTTLER HAMMER / C&S 66 Supply only (PCB Card ) suitable for 01 x 26 TR Capacity AC Plant of Make Blue Star Model No XAC 25024 MAR 2 67 Supply & fixing in repair Bty 12 V 1.2 AH suitale for Package type AC Plant of capacity 3 TR 68 Supply and fixing in repair AC variable voltage & variable frequency (VVVF drive) drive with sheet metal enclosure including electrical connection with suitable size of cable complete with all standard accessories conforming to IS: 14665, simple collective selective automatic and manual dual controlledoperation with/without attendant,automatic speed control ofmotor capacity 25 HP for AHU 28000CFM complete all as specified and as directed by Engr in Charge, 69 Supply & fixing in repair MCCB 40 Amp, Three Pole, breaking capacity 25 KA, 415 V - 50 Hz, fixed in existing panel & connecting complete all as specified & directedby Engr in charge. 70 Supply & fixing in repair MCCB 125 Amp, Four Pole, breaking capacity 36 KA, 415 V - 50 Hz, fixed in existing panel & connecting complete all as specified & directedby Engr in charge. 71 Supply & fixingin repair MCCB 160 Amp, Four Pole, breaking capacity 36 KA, 415 V - 50 Hz, fixed in existing panel & connecting complete all as specified & directedby Engr in charge. 72 Supply & fixingin repair MCCB 400 Amp, Four Pole, breaking capacity 36 KA, 415 V - 50 Hz, fixed in existing panel & connecting complete all as specified & directedby Engr in charge. 73 Supply and fixing in repair MCB 32 Amp 3 Pole , 415 Volt 10 KA C Curve complete all as specified and as directed 74 Supply and fixing in repair HRC Fuse unit of capacity 250 Amp complete all as specified and as directed by Engr-in- charge 75 M&L for taking out Pump along with motor of capacity 11 KW from central type AC plant, opening the motor, cutting & removing old and burnt winding wire, rewinding the motor with new super enameled copper winding wire of suitable size including insulating materials, varnishing, drying, replacement of both driven end non driven end bearings and base plate, reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & directed. 76 M&L for taking outMotor & pump of 7.5 KW/ 10 HP cap , Dismantling the motor with disconnecting the same from the compressor and remove rubber coupling and its connected accessories and transporting to reputed work shop for rewinding . opening themotor, cutting & removing old and burnt windingwire, rewinding the motor with new super enameled copper winding of suitable size including insulating materials, varnishing, drying, replacement of both driven end non driven end bearings and base plate,reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & directed 77 M&L for taking out AHU blower Motor 13 KW/17HP cap , Dismantling the motor with disconnecting the same from the compressor and remove rubber coupling and its connected accessories and transporting to reputed work shop for rewinding . opening themotor, cutting & removing old and burnt windingwire, rewinding the motor with new super enameled copper winding of suitable size including insulating materials, varnishing, drying, replacement of both driven end non driven end bearings and base plate,reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & directed 78 M&L for taking out AHU blower Motor 5 HP cap , Dismantling the motor with disconnecting the same from the compressor and remove rubber coupling and its connected accessories and transporting to reputed work shop for rewinding . opening themotor, cutting & removing old and burnt windingwire, rewinding the motor with new super enameled copper winding of suitable size including insulating materials, varnishing, drying, replacement of both driven end non driven end bearings and base plate,reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & directed 79 M&L for taking out Pump along with motor of capacity 11 KW (406 USGPM & 486 USGPM) fromBMS central type AC plant, opening the pump, removing old mechanical seal and replaced with new mechanical seal of same size including impeller shaft, replacement of both end bearings and base plate, reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & directed 80 Comprehensive / Preventive maintenanceincluding servicing of Package Air conditioning of fallowing capacities, maintenece shall be carried out as per manufacturer standard check list and detailed as under all as directed by Engineer-in-Charge.(a) Cleaning the evaporator coil of indoor unit with pressureized water then apply one coat of descaling solution and clean with nylon brush and then testing/ checking of evaporator coil for leakage and rectification of leakage by brazing including.. (b) Cleaning of condensing coil of outdoor unit with pressurised water and then testing/ checking of Cooling coil for leakage and rectification of leakage by brazing including.(c) Testing / Checking and Cleaning of Air filter.(d) Testing / Checking of compressor for its proper functioning and rectification of minor defect if any.(e) Testing / Checking & servicing of blower fan motor and rectification of minor defect if any.(f) Testing / Checking & servicing of condenser fan motor and rectification of minor defect if any.(g) Testing / Checking of control switch such as pressure cut outs, refrigerent flow switch, temprature sensore for proper functioning.(h) Testing / Checking of refrigerant pipe for leakage and Rectification of leakage by brazing including cleaning of refrigerant pipe.(j) Testing / Checking of all electrical connection and control wiring tighting of electrical connection and rectification of minor defect if any complete. 81 NOTE :-(i) Comprehensive / Preventive maintenance including servicing of Package AC unit shall be carried out as per manufacturer standard check listand not less then six months interval from last maintenance and carried out onetimes during contract period and shall be measured one times, Contractor shall also be responsible to rectify any defect during break down without any extra cost during contract period complete all as directed by Engineer-in-Charge. (ii) Charging of gas, if required, shall be measured and paid for separately under appropriate item. However, vacuum and pressure leakage testing with nitrogen (N2), if any required, is deemed to be included under the unit rate quoted by the contractor for this item.(iii)After completion of Comprehensive / Preventive maintenance including servicing of Precision type Package AC unit shall be tested by the contractor all as directed by the Engineer-in-Charge. 82 Package Air conditioning unit (Make: Emerson, Model: PEX-135 EC I-COM) of Capacity 10 TR 83 Package Air conditioning unit (Make: Bluestar, Model: DPA2163R3-I) of Capacity 33000K/cal/Hr 84 Precision type Package Air conditioning unit (Make: Emersion, Model: PEC113 RA/DA withI Com) of Capacity 3.0 TR 85 Precision type Package Air conditioning unit (Make: Emersion, Model: PEC120 RA/DA withI Com) of Capacity 5.0 TR 86 Precision type Package Air conditioning unit (Make: Emersion, Model: PEC130 RA/DA withI Com) of Capacity 7.5 TR 87 Material and labourfor maintenance of Precision type Package Air conditioning along with cost of replacement of old/unsv spare parts as underincluding testing on load complete all as specified and as directed by Engr-in-charge 88 Supply only Evaporator centrifugal blower motor with rotor of same size and capacity of Precision type Package Air conditioning. 89 Supply only condenser fan motor with blade of same size and capacity of Precision type Package Air conditioning. 90 Supply only LP cutout for compressor of Precision type Package Air conditioning. 91 Supply only HP cutout for compressor of Precision type Package Air conditioning. 92 Supply only microwave filter for compressor of Precision type Package Air conditioning. 93 Supply only filter liquid drier for compressor of Precision type Package Air conditioning. 94 Supply only Micro-processing Controller (I Com)(PCB Card )of Precision type Package Air conditioning. Upto 10 TR Capacity all as specified and as directed by Engr-in-charge 95 Supply only Infrared Humidifier of Precision type Package Air conditioning. 96 Supply only Expansion Valve for compressor of precision Air conditioning unit complete all as specified and directed by Engg -in-charge Make Emersion 97 Supply only Air sensor for compressor of precision Air conditioning unit all as specified and directed by Engg -in-charge MakeEmersion 98 Supply only Printed Circuit Board of Precision type Package Air conditioning of capacity 33000 kcal/Hr unit all as specified and directed by Engg -in-charge Make: Blue Star 99 Supply only Condenser fan motor with blade of Precision type Package Air conditioning of capacity 33000 kcal/Hr unit all as specified and directed by Engg -in-charge Make: Blue Star 100 Supply only Pre Filter box type suitable for Precision type package Air conditioning of capacity upto 10 TR all as specified and directed by Engg in charge . Note : Filter size be vary as per the capacity of the package AC Plant. No extra cost will be paid to the contactor to provide different size of filter as per site requirement. 101 Supply, filling & testing in repair of Water softener filter (Cation Exchange) with all necessary equipment of capacity 3 cum/hr complete all as specified and directed by Engr-in-charge. 102 Supply, filling & testing in repair of 40x40 RO membrane of capacity 1 Micron, Max operating pressure at 300 PSI complete all as specified and directed by Engr-in-charge.Make : PENTAIR, Model No 40L30N 103 Supply, filling & testing in repair of multi plot valve mounted at polyglass pressure vessel to control the direction of flow complete all as specified and directed by Engr-in-charge. 104 Receiving and attendingcomplaints fromconcern Incharge ofAC sectionlodged by the occupants/user of Central/Package/VRF/VRV air conditioningnature and making plant/unit in serviceable condition in including followingrectification of error showing in display, electrical fault if any , repair/replacement of minor parts andrectifingthe fault ,complete all as directed at site to the entire satisfaction of Engr-in-charge/users.Note - (i) spare partsrequired for repairing will be paid under relavent supply only items of this schedule.2. fixing cost of replacement of any part are deemed to be included in the quoted rate 105 supply & fix in repair hermetically sealed Scroll Compressor with base frame & electric phase reversal protection of capacity 7.5 TR of Precision type Package Air conditioning (Make: Emersion, Model: PEC130 RA/DA with I Com) comprising fallowing job:-(i) Charging of nitrogen gas in unit & complete system at 300 psi pressure and checking of any dropping of pressure/ leakage upto 72 Hrs after replacement of compressor & rectification of leakage if any.(ii) Vaccumisation of complete system for minimum 2 days for dropping of vaccume pressure & rectification of leakage if any.(iii) Charging of complete system with R-407 gas for maitaining the system pressure upto HP-175 psi & LP-65 psi(iv) Measure the inlet and outlet temperature of package unit.(v) Testing and commisioning of compressor after completion.Make: Godrej/Teccumesh /Emerson copland 106 supply & fix in repair hermetically sealed Scroll Compressor with base frame & electric phase reversal protection of capacity 03 TR of Precision type Package Air conditioning (Make: Emersion, Model: PEC113 RA/DA with I Com) comprising fallowing job:-(i) Charging of nitrogen gas in unit & complete system at 300 psi pressure and checking of any dropping of pressure/ leakage upto 72 Hrs after replacement of compressor & rectification of leakage if any.(ii) Vaccumisation of complete system for minimum 2 days for dropping of vaccume pressure & rectification of leakage if any.(iii) Charging of complete system with suitable gas for maitaining the system pressure upto HP-175 psi & LP-65 psi(iv) Measure the inlet and outlet temperature of package unit.(v) Testing and commisioning of compressor after completion.Make: Godrej/Teccumesh /Emerson copland 107 Supply and toping up refrigerant gas R-22 to the central / package AC plant of any capacity system all as directed by the Engineer in charge. 108 Supply and toping up refrigerant gas R-410 A to the central / package AC plant of any capacity system all as directed by the Engineer in charge. 109 Supply and toping up refrigerant gas R-407 C to the central / package AC plant of any capacity system all as directed by the Engineer in charge. 110 Supply and toping up refrigerant gas R-134 A to the central / package AC plant of any capacity system all as directed by the Engineer in charge. 111 Note for Item Ser No 1 to 6, 9, 13, 16, 49 &50 : Cost of necessary tools and plant/technician for toping up of refrigerant are deemed to be included in the quoted rate. 112 Supply and Charging Lubricating Oil for scroll type compressor (Mineral oil SUILE BSE 170) complete all as specified and directed by Engineer-in-Charge.Make: Bitzer/Synthetic refrigeration compressor oil 113 Supply , Installation , testing , commissioning of fan assembly unit suitable for 180 TR chiller of size 800mm dia fixed in repairs all as specified and directed by Engr-in-charge . Make Voltas, ZAHIL , ABEGG 114 supply and fixing in repair filter liquid drier suitable for 90 TR compressor of air cooled central AC Plant complete all as specified and as directed by Engr-in-charge Make Danfoss or any other make approved by GE 115 Supply and fixing in repair Solonide valve suitable for 90 TR compressor of air cooled central AC Plant complete all as specified and as directed by Engr-in-chargeMake Danfoss or any other make approved by GE 116 Supply and fixing in repair expensionvalve controllersuitable for 180 TR chiller unitof air cooled central AC Plant complete all as specified and as directed by Engr-in-charge , Model EXV Driver , supply voltage 110V-240 V AC Make Danfoss or any other make approved by GE 117 Supply and fixing in repairmainelectroniccircuit control board of Central type AC plant (MAKE : BLUE STAR Model No :XAC5S060MAR2) of capacity 50 TR including connecting complete.Make as per manufacturer recommendation after written approval by The GE 118 Supply and fixing VRF cassett AC indoor unit of capacity 4.1 TR complete all as specified and as directed by Engr-in-charge 119 Supply and fixing in repair EC fan motor assembly (including fan) complete of I Com Package AC for Indoor unit all as specified and as directed by Engr-in-Charge 120 Supply and fixing in repair scroll type compressor suitable forPrecision type Package Air conditioning of capacity 33000 kcal/Hr unit all as specified and directed by Engg -in-charge Make: Blue Star Model No DPA2163R3-I 121 Supply and fixing in repair blower motorsuitable for indoor unit ofPrecision type Package Air conditioning of capacity 33000 kcal/Hr unit all as specified and directed by Engg -in-charge Make: Blue Star Model No DPA2163R3-I 122 Supply and fixing in repairMVPD 30 - 220 Amp , Model - EC Aux Supply - 230VAC complete all as specified and as directed by Engr in Charge 123 Supply and fix in repair Display Controller unit of Industrial type Air conditioning of capacity 2.0 TR.Model:- MCH2EP1031, Make-CARELor any other make as per recommendation of OEM and approved by the GE. 124 M&L for Painting of complete water cooled central AC Plant(comprising 3 Nos chiller unitof capacity193536 K Cal/Hr, pipe lines, valves, pump sets (04 Nos), steel surface, AHU pipe lines and chiller pipes etc) by preparation of old painted surface removing of dirt / dust / oil grease etc and applying two coat of synthetic enamel paint all as specified and directed by Engg-in-Charge. 125 M&L for Painting of complete Air cooled central AC Plant of capacity 102 TR (comprising 4 Nos chiller unitof capacity 34 TR, pipe lines, valves, pump sets (04 Nos), steel surface, AHU pipe lines and chiller pipes etc) by preparation of old painted surface removing of dirt / dust / oil grease etc and applying two coat of synthetic enamel paint all as specified and directed by Engg-in-Charge. 126 M&L for Painting of complete Air cooled central AC Plant of capacity 52 TR (comprising 3 Nos chiller unitof capacity 26 TR, pipe lines, valves, pump sets (03 Nos),steel surface, AHU pipe lines and chiller pipes etc) by preparation of old painted surface removing of dirt / dust / oil grease etc and applying two coat of synthetic enamel paint all as specified and directed by Engg-in-Charge. 127 M&L for Painting of complete water cooled central AC Plant of capacity 60 TR (comprising 3 Nos compressor of capacity 30 TR, pipe lines, valves, pump sets, cooling tower steel surface, AHU pipe lines and chiller pipes etc) by preparation of old painted surface removing of dirt / dust / oil grease etc and applying two coat of synthetic enamel paint all as specified and directed by Engg-in-Charge. 128 S&F in repair gate valve 20mm dia with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed by Engr-in-charge 129 Supply , installation, testing and commissioning in repalcementof PN 16 Butterfly valves of 150mm dia (MS Pipe) duly insulated with companion flanges, nuts, bolts, gaskets etc as specified , Butterfly valves with cast iron body, seat of black nitrite rubber, nylon coated SG iron disc PTFE coated SS (AISI 410) shaft etc as required . These valve shall conforming to BS 5155, MSS SP 67 & API 609 and shall be desiged to fit without gasket between mating flanges. The valves shall be suitable for flow in either direction and seal in both direction . 130 Supply, inastallation, testing and commissioing in repalcement of mild steel chilled water piping of class C heavy duty conforming to IS : 1239 (part I) 1991 and IS : 3589 to 1991 grade 330 of size 150 mm dia thickness 5.40mm, cut to reqd length, and installed with welded joints, including all necessary fittings such as elbows, tees, bends, reducers, flanged, supports, Air purge, valves, drain valve etc. duly insulated and as per specification 50mm thick TF quality EPS pipe section insulation of 18 Kg/ cum density and covered with 28 gauge aluminium sheet caleding and as per specification. Make : TATA/Jindal/Zenith / Surya Prakash 131 Supply, inastallation, testing and commissioing in repalcement of mild steel chilled water piping of class C heavy duty conforming to IS : 1239 (part I) 1991 and IS : 3589 to 1991 grade 330 of size 125 mm dia thickness 5.40mm, cut to reqd length, and installed with welded joints, including all necessary fittings such as elbows, tees, bends, reducers, flanged, supports, Air purge, valves, drain valve etc. duly insulated and as per specification 50mm thick TF quality EPS pipe section insulation of 18 Kg/ cum density and covered with 28 gauge aluminium sheet caleding and as per specification. Make : TATA/Jindal/Zenith / Surya Prakash 132 Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5mtr in depth for foundation and laying of under ground cables / pipes in soft/loose/muddy soil and getting out all as directed. 133 Excavation in trenches n.exc 1.5 mtr wide and not exc 3mtr depth and getting out in soft/loose/muddy soil all as directed. 134 Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm complete all specified and as directed. 135 Removal of surplus excavated soil to a distance not exceeding50metre and depositing where as directed at a level not exceeding1.5metre above the starting point, complete all as specified and as directed. 136 Note for item No 13 to 85:- (a) Comprehensive / Preventive maintenance shall be carried out as per manufacturer standard check listand not less then six months interval from last maintenance andall as directed by Engineer-in-Charge.(b) Testing / Checking for its proper functioning and rectification of defect replacement of unserviceable parts consumable as required , cleaning and testing.(c) Contractor shall also be responsible to rectify any defect and maintain plant in running condition within 24 hours during break down, without any extra cost to govt during contract period. Failure to repair will attract penalty of @1000/per day, decision of GE in this regard final and binding(d) All defective speare parts & compressor etc if found unserviceable will be measured & paid separately as supply only under respective items of This BOQ, any other item not mentioned in BOQ if required will be provided and quoted rates for the same is included in rates of comprehensive maintenance .(e)The rates quoted by the tenderer shall be deemed to include for any minor repair, which are obviously and fairly, intended which may not have been included in these documents, but which are essential for the execution and entire completion of works.The decision of the engr-in-charge as to what constitutes Minor details shall be final and binding.(f) Labour charges for, taking out old and supply new spares, T&P and Misc charges, items to be deemed to be included in the quoted rate for Comprehensive maintenance i.e. (g) Make of sapre part shall be as recommended by the OEM and the same shall be used only after approval by the GE.(h) Unserviceable parts shall be property of contractor as per credit schedule
Contract Date : 20 Jan, 2025   |   Contract Value : 56.81 Lakhs
BRR : 9619171 Tender For Repair/ Maintenance Of All Types Of Pumps And Motors ,Fountains,Cleaning Of Oht/Ug Sumps And Other Misc Items At Wac Area Under Ge (Af) Subroto Park; 1 Excavation in trenches in any type soil /rock (soft/loose/hard/dense soil/rock) n.exe 1.5 mtr wide and n.exe 1.5 mtr in depth for foundation laying of pipe etc n.exe 10 sqmm on plan and n.exe 1.5 mtr in depth and getting out complete all as specified and as directed by Engineer-in-charge. NOTE : while removing the pipe line. Contractor shall refixed the oldtiles as per existing . The quoted rates including for all the materials / t&p / machinery used in this item no material can paid / measured seperately 2 Returning filling in including spreading levelling watering and well ramming hard / dense soil in layers not.exe 25cm Each layers complete all as specified and as directed by Engineer-in-charge 3 Removal of excavated material & surplus spoil to a distance n.exe 50 mtr and depositing where directed at a level not exe 1.5 mtr above the starting point complete all as specified and as directed by Engineer-in-charge 4 Supply and fixingin replacement of unserviceable sluice valve cast iron with brass spindle PN-1.6 long body type and fly nut flanged both ends and drilled for jointing wheel head type confoRMing to IS 14846 including two flanged joints with nuts bolts and washers rubber insertion packing etc for 250mm bore pipe as in repairs and ISI marked complete all as specified and as directed. 5 All as per above item No 4 here-in-before but 200mm bore 6 All as per above item No 4 here-in-before but 150mm bore 7 All as per above item No 4 here-in-before but 100mm bore 8 All as per above item No 4 here-in-before but 80mm bore 9 Supply and fixingin replacement cast iron non return valve flanged end confoRMing to IS 5312 of size 80mm dia complete with rubber flange, MS nuts & bolts complete all as specified and as directed by Engineer-in-charge. 10 All as per above item No 9.00 here-in-before but 100mm dia 11 All as per above item No 9.00 here-in-before but 150mm dia 12 All as per above item No 9.00 here-in-before but 200mm dia 13 Supply and fixingin replacement of unserviceable jointing to cast iron pipe of size 250mm bore spigot and socket by run lead joints including spun yarn and caulking of lead joints complete all as specified and as directed by Engineer-in-charge 14 All as per above item No 13 here-in-before but 200mm bore 15 All as per above item No 13 here-in-before but 150mm bore 16 All as per above item No 13 here-in-before but 100mm bore 17 All as per above item No 13 here-in-before but 80mm bore 18 Taking out existing GI pipe 100mm dia from trenches / walls / roof / floor etc including connection and making good to distrubed area (surface of walls / floor etc) complete all as specified and as directed by Engineer-in-charge 19 All as per above item No18.00 here-in-before but size 80mm bore 20 All as per above item No18.00 here-in-before but size 50mm bore 21 All as per above item No18.00 here-in-before but size 40mm bore 22 All as per above item No18.00 here-in-before but size 25mm bore 23 All as per above item No18.00 here-in-before but size 20mm bore 24 All as per above item No18.00 here-in-before but size 15mm bore 25 Supply and fixingGI tubing medium grade 100mm dia with all fittings complete laid in trenches / on walls / on ceiling / roof etc incl necessary suitable size of MS clamps / saddling on walls / ceiling etc complete all as specified and as directed by Engineer-in-charge. 26 All as per above item No 25.00 here-in-before but size 80mm dia bore 27 All as per above item No 25.00 here-in-before but size 50mm dia bore 28 All as per above item No 25.00 here-in-before but size 40mm dia bore 29 All as per above item No 25.00 here-in-before but size 25mm dia bore 30 All as per above item No 25.00 here-in-before but size 20mm dia bore 31 All as per above item No 25.00 here-in-before but size 15mm dia bore 32 Cutting and screwing to existing MS / GI steel tubing for alteration or addition to pipe line of 40 to 50mm bore with new fittings and fixtures complete all as directed by Engineer-in-charge 33 All as per above item No 32.00 here-in-before but size 80 to 100 mm dia bore 34 Supply and fixingin replacement of unserviceable gun metal globe or gate valve with iron wheel head screwed both ends for iron pipe 50mm dia complete all as specified and as directed by Engineer-in-charge. 35 All as per above item No 34.00 here-in-before but size 32 /40mm dia bore 36 All as per above item No 34.00 here-in-before but size 25mm dia bore 37 All as per above item No 34.00 here-in-before but size 20mm dia bore 38 All as per above item No 34.00 here-in-before but size 15mm dia bore 39 Supply and fixing in replacementbrass butterfly valve class PN-1.0 of size 50mm diacompleteall as specified and directed . 40 Supply and fixing in replacementbrass butterfly valve class PN-1.0 of size 40 mm dia complete 41 Supply and fixing in replacementbrass butterfly valve class PN-1.0 of size 25mm diacomplete 42 Supply and fixing in replacementbrass butterfly valve class PN-1.0 of size 20mm diacomplete 43 S&F in replacement gun metal non return valve of size 15mm bore 44 S&F in replacement gun metal non return valve of size 20mm bore 45 S&F in replacement gun metal non return valve of size 25mm bore 46 S&F in replacement gun metal non return valve of size 40mm bore 47 S&F in replacement gun metal non return valve of size 50mm bore 48 Supply and fixingin replacement of unserviceable PVC bib tape 15mm dia complete all as specified and directed. 49 Supply and fixingin replacement of unserviceable PVC PTMT float valve 20/25 mm dia complete with PVC ball and connecting rod complete all as specified and directed. 50 Supply & Fixing In Replacement Of Water Meter 150mm Bore Including Rubber Packing Sheets, Nuts, Bolts Etc complete all as specified and directed. 51 M&L Brick work with sub-class B bricks straight on plan built in CM 1:4 for pipe line supports including demolition of old brick work complete all as specified and directed. 52 M&L for PCC 1:2:4 type B-1 using 20mm graded aggregate built in CM for copping pipe liner support 53 M&L for PCC foundation 1:2:4 type B-2 (using 40mm graded stone aggregate)complete all as specified and directed. 54 M&L for plastering work 15mm thick on fair faces of brick work on concrete surfaces in 1:4 cement mortar for pillar supports 55 Making good for road to existing surfaces with using of patch premix bitumenous 25mm thick polymer based material over WBM 75mm thick including rolling etc all as specified and as directed by Engineer-in-charge 56 M & L for earthing in rocky area by usingBurnished metal copper earthing electrode 50mm dia 3 Mtr long with strip teRMinal 40x5mm, 90mm length with 2 holes of10mm with the pipe thickness of 1.2 mm non exotheRMic welding, inner electrode 16mm solid rod, filled with highly conductive compound non corrosive non hydroxylation Inclusive of 2 bag of Chemical earthing electrode 50 kgs, 25kg bag Each with the chemical composition Carbon as graphite 80%, AI203 18-32%, FE203 4-11%, CALCIUM,CARCBON, COPPER 10 to 15 %. Moisture Content 1.06%, chloride 300ppm, cadmium not detected, antimony 100pm to ensure resistance value less than 5 ohm all as specified and directed. Note: (i) The rate quoted for above includes all necessary materials, T& P for excavation etc for achieving the desire result of less than 5 ohm.(ii) Earth pit chamber, cover and marking also included in the unit quoted rate of item.(iii) Earthing shall be carried out through OEM only. 57 M&L for earth continuity conductor of size 25mmX4 mm galvanised strip strip fixed on walls / burried in ground with and including fixing arrangments on walls like porcelain insulators screws washers etc complete all as specified and as directed by Engineer-in-charge 58 M&L for Construction of brick masonary valve pit of size 100cmx100cmx100cm (internal dimensions of chamber) depth to be reconed from the top of PCC in foundation to top of MS cover with MS sheet cover 3.15mm thick including frame of angle iron 40x40x6mm with locking arrangement including painting two coats of black synthetic enamel paint over a coat of red oxide primer etc including brick work in CM 1:6 15mm thick plastering in CM 1:4 (internal & external) and necessary excavation and earth work in any type of soil, returning, filling in disposal of surplus spoil to a distance not exe 50 mtrs 150mm thick PCC 1:4:8 type D-2 for base and PCC copying 15mm thick 1:2:4 using 12mm graded aggregate all as specified and as directed by Engineer-in-charge) for upto 250mm dia valve) 59 Supply & fixing in replacement of 100mm CI foot valve complete all as specified and as directed by Engineer-in-charge. 60 Supply & fixingCI air release valve of dia 150mm bore dia complete with all accssories incl taking down old unsv air release valveall as specified and directed by engr in charge. 61 Disconnecting and taking out of existing submersible pump set from borewell capacity 3 to 7.5 HP alongwith their column pipe and submersible cable from bore well from any depth complete all as specified and directed by Engineer-in-charge 62 Lowering the submersible pump set complete with motor and pump capacity 3 to 7.5 HP in bore well and connecting to existing system complete all as specified and as directed by Engineer-in-charge 63 Development of borewell by means of high capacity compressor, compressor capacity not less than 620 CFM at 8 Kg/cmsquare to its optimum yeild till clear water of potable quality free from sand/silt is obtained including draw down performance and yeild test of the tubewells complete all as specified and directed by Engr- In- Charge. 64 Dismantling and strip opening of submersible pump multistage coupled with 3 HP to 7.5 HP submersible motor of any make, segregating of serviceable/unserviceable parts, cleaning of serviceable parts, assemblingpump carefully including replacement of worn-out parts, nut and bolts etc., grinding and polishing of shaft for fixing of bushes neckering bushes, making proper size of keysfor fixing of impeller etc, getting coupled to the pump with motor, testing for rated dischargeof water including transportation to the site for lowering complete all asspecified and directed. Note:- (i) The unit quoted rate included the items required like guide bush,distance sleeves,impeller key , cable guard SS distance sleeves ,guide bush,GM neck ring ,stage ball or any other such itemsrequiredfor pump to make fully functional.(ii) Only item considerd in supply only of this schedule will be paid separetely. 65 Shifting to local work shop and Rewinding of submersible motor after cutting the burnt winding including cleaning slots and rewinding with equivilent gauge (as retrieved) ofinsulated copper winding wire and insulating material I.e PVC sleeves insulation paper , wooden sticks, O ring for 3.0 HP to 7.5 HP complete all as specified and as directed by Engineer-in-charge.Note:-(i) The unit quoted rate included the items required like stamping,rotor sleeves,T-bolt,sand guard,coupling ,bearing base plate,bearing ,bush,water cable seal, seal bush& sleeves ,revolving disc etc for motor to make fully functional.(ii) Only item considerd in supply only this schedule will be paid separetely. 66 Supply only impeller of existing material suitable for 3 HP to 7.5 HP submersible pump set complete all as specified and as directed by Engineer-in-charge. 67 Supply only thrust plate suitable forfor 3 HP to 7.5 HP submersible motor 68 Supply only thrust bearing suitable for 3 HP to 7.5 HP submersible motor 69 Supply only Gun metal bearing suitable for 3 HP to 7.5 HP submersible motor 70 Supply only SS rotor sleeves infor 3 HP to 7.5 HP submersible motor 71 Supply only coupling suitablefor 3 HP to 7.5 HP motor 72 Supply only SS pump Shaftfor 3 HP to 7.5 HP submersible pump 73 Supply only housing upper and lower for 3 HP to 7.5 HPsubmersible 74 S&F in replacement GI column pipe 50mm dia heavy duty class C with GI flanged and drilled at both ends duly threaded and welded of 3 mtr long including bolts, nuts, washers and rubber insertions packing complete all as specified and directed by Engineer-in-charge. 75 Dismantling & taking out open well submersible pump sets installed at water storage tank of fountains, pumphouse and booster pump sumps of capacity 2 to 4 HP after disconnecting all electrical connections and refixing the same in its original position after carrying out repairs / rewinding over hauling cleaning of impellers strainers including reconnection of all electrical connections etc complete all as specified and as directed by Engineer-in-charge. Note:- (i) The unit quoted rate included the items required likeguide bush,distance sleeves,impeller,impeller key , cable guard SS distance sleeves ,guide bush,GM neck ring ,stage ball,DOL piece,DOL bush etc for open well pump to make fully functional.(ii) Only impeller and rewinding will be paid separetely . 76 All as per above item No 75.00 here-in-before butof capacity 5 to 7.5 HP 77 All as per above item No 75.00 here-in-before butof capacity 10 to 15 HP 78 All as per above item No 75.00 here-in-before butof capacity 30 HP 79 M&L for transportation of open well centrifugal type submersible pump set of capacity 2.0 HP to 4.0 HP to local work shop and rewinding the motor with equivalent gauge of insulated copper winding wire & insulating materials i.e. PVC sleeves insulation papers wooden stick O ring complete all as specified and as directed by Engineer-in-charge.Note:-(i) The unit quoted rate included the items required like stamping,rotor sleeves,T-bolt,sand guard,coupling ,bearing base plate,bearing bush,upper and lower housing,thrust plate and thrust bearing,water cable seal, seal bush& sleeves ,revolving disc etc for motor to make fully functional. 80 All as per above item No 79.00 here-in-before butof capacity 5.0 to 7.5 HP 81 All as per above item No 79.00 here-in-before butof capacity 10 to 15 HP 82 All as per above item No 79.00 here-in-before butof capacity 30 HP 83 Supply only impeller for existing material suitablefor 2 HP to 4 HP open well submersible 84 Supply only impeller for existing material suitablefor 5 HP to 7.5 HP open well submersible 85 Supply only impeller of existing material suitablefor 10 HP to 15 HP open well submersible 86 Supply only impeller of existing material suitablefor 30 HP open well submersible 87 Dismantling & taking out defective parts of monoblock pump set of capacity 0.5 HP to 1.5 HP and refixed after repairs / making complete serviceable by repairing / replacement of defective parts including tranportation to local work shop etc complete all as specified and directed by Engineer-in-charge. Note : -(i)Replacement of defective parts also included in the unit quoted rate.No extra payment shall be given for parts. (ii) Rewinding of motor shall be given seperately. 88 All as per item no 87.00 above but for 2.0 HP to 4.0 HP 89 M&L for rewinding of Booster Pump set of capacity 0.5 Hp to 1.5 HP with same gauge of super enamelled copper winding wireafter cutting the burnt windings cleaning slots including insulating materials PVC sleeves insulation paper wooden stick etc complete all as specified and as directed by Engineer-in-charge 90 All as per item no 89.00 above but for 2.0 HP to 4.0 HP 91 Supply only cooling fan for 0.5 to 4.0 HPmotor 92 M&L Dismantling of unserviceable monoblock / Centifugal pump set, with motor for 5 HP to 7.5 HP, strip opening and taking out or rotor carefully, cleaning of rotor and stator, checking the rotor bearings, pump bearings, gaskets, impeller keys, teRMinal plate, gun metal bushes, cooling fan blades, windings etc., re-assembling the motor including replacement of studs with nuts, retesting of motor winding and motor for full RPMand full discharge water after coupling with pump set complete all as specified and directed.Note : -(i)The unit quoted rate included the items required like bearings ,bearing housing ,shaft sleeve ,suction delivery piece,gland plate,gland packing,mechanical seal ,stuffing bush,gasket,nut stud,eye bolt,seal packing etc for Monoblock/centrifugal pump to make fully functional.No extra payment shall be given for parts. (ii)Only cooling fan, shaft,impeller and rewinding will be paid separetely. 93 All as per item no 92.00 above but for 10.0 HP to 15 HP motor 94 M & L for centrifugal type induction motor of capacity5.0 HP to 7.5 HP to local work shop and rewinding the motor with equivalent gauge of insulated copper winding wire & insulating materials i.e. PVC sleeves insulation papers wooden stick O ringincluding refixing in its original position and testing completeall as specified and as directed by Engineer-in-charge. Note : -(i)The unit quoted rate included the items required like bearings ,bearing plate ,coupling key,connectionplate,teRMinal box,fan cover,stamping etc for motor to make fully functional.No extra payment shall be given for parts. 95 All as per item no 94.00 above but for 10.0 HP to 15 HP motor 96 Supply only cooling fan for 5.0 to 7.5 HPmotor 97 Supply only shaft of existing material suitable for 5 HP to 7.5 HP 98 Supply only impeller of existing material suitable for 5 HP to 7.5 HP 99 Supply only cooling fan for 10.0 to 15.0 HPmotor 100 Supply only shaft of existing material suitable for 10.0 to 15.0 HPmotor 101 Supply only impeller of existing material suitable for 10.0 to 15.0 HPmotor 102 M&L Dismantling of unserviceable monoblock / Centrifugal pump set, with motor for 30 HP to 50 HP, strip opening and taking out or rotor carefully, cleaning of rotor and stator, checking the rotor bearings, pump bearings, gaskets, impeller keys, teRMinal plate, gun metal bushes, cooling fan blades, windings etc., re-assembling the motor including replacement of studs with nuts, retesting of motor winding and motor for full RPMand full discharge water after coupling with pump set complete all as specified and directed.NOTE- (i).The unit rate quoted by the contractor shall also include the cost of removing the motor and pump set to perfoRM the works mentioned in this item. (ii) Any parts / spares required to make it fully functional shall be measured and paid for separately under relevant item as supply only. 103 All as per item no 102.00 but for monoblock/centrifugal pump set60 HP to 75 HP 104 M & L for centrifugal type induction motor of capacity30 HP to 50 HP to local work shop and rewinding the motor with equivalent gauge of insulated copper winding wire & insulating materials i.e. PVC sleeves insulation papers wooden stick O ringincluding refixing in its original position and testing complete ( other spares required for motor will be measuerd and paid under relevant item ) all as specified and as directed by Engineer-in-charge. 105 All as per item no 104.00 but for induction motor of 60 HP to 75 HP 106 Supply only shaft of existing material suitable for 30 to 50 HP motor 107 Supply only impeller of existing material suitable for 30 to 50 HP motor 108 Supply only shaft sleeve of existing material suitable for30 to 50 HP 109 Supply only Cast iron bearing housing for 30 to 50 HP motor 110 Supply only Gland assembly suitable for 30 to 50 HP motor 111 Supply only throatbush suitable for 30 to 50 HP motor 112 Supply only mechanical seal suitable for 30 to 50 HP motor 113 Supply onlyshaft coupling suitable for 30 to 50 HP pump set 114 Supply only ball bearing suitable for 30 to 50 HP pump set 115 Supply only roller bearing suitable for 30 to 50 HP 116 Supply only cooling fan for 30 to 50 HP induction motor 117 Supply only shaft of existing material suitable for 60 HP to 75 HP 118 Supply only impeller of existing material suitable for 60 HP to 75 HP 119 Supply only shaft sleeve of existing material suitable for 60 HP to 75 HP 120 Supply only Cast iron bearing housing for 60 HP to 75 HP 121 Supply only Gland assembly suitable for 60 HP to 75 HP 122 Supply only throatbush suitable for 60 HP to 75 HP 123 Supply only mechanical seal suitable for 60 HP to 75 HP 124 Supply onlyshaft coupling suitable for 60 HP to 75 HP pump set 125 Supply only ball bearing suitable for 60 HP to 75 HP 126 Supply only roller bearing suitable for 60 HP to 75 HP 127 Supply only cooling fanfor 60 HP to 75 HP induction motor 128 Dismantling of pressure pump set of Cap 0.5 HP to 1.0 HP from the existing site after disconnecting all electrical connections and refixing the same after carrying out repairs /overhauling of pump including transportation to local work shop & back complete all as specified and as directed by Engineer-in-charge.Note : -(i)Replacement of defective parts also included in the unit quoted rate.No extra payment shall be given for parts.(ii) only Rewinding of motor shall be paid seperately. 129 M&L for rewinding of pressure Pump set of capacity 0.5 Hp to 1.0 HP with same gauge of super enamelled copper winding wireafter cutting the burnt windings cleaning slots including insulating materials PVC sleeves insulation paper wooden stick etc complete all as specified and as directed by Engineer-in-charge.Note : -(i)Replacement of defective parts to made motor functional also included in the unit quoted rate.No extra payment shall be given for parts. 130 S&F in replacement of Air Tank for pressure pump set of capacity 0.5 HP 1.0 HP 131 S&F in replacement of Pressure gauge 0-10 Kg / SqCM 132 S&F pressure control switch suitable for 0.5 HP/1.0 HP pressure pump set 133 S&F in replacement Running Capacitor 10.0 MFD 134 S&F in replacement Running Capacitor 25.0 MFD 135 S&F in replacement Running Capacitor 36.0 MFD 136 S&F in replacement Running Capacitor 50.0 MFD 137 S&F in replacement Running Capacitor 72.0 MFD 138 S&F in replacement Running Capacitor 125.0 MFD 139 S&F In Replacement CIImpeller Assy of Centrifugal mono block Pump set of capacity 0.5 HP to 1.5 HP as per sample (size varies depend upon the make and cap) 140 Supply & Fixing pressure booster pump 1 HP capacity single phase, 50 Hz mounted on roof for boosting water supply to high pressure and connected with existing water supply pipe line including necessary electrical wire and plug top , NRV socket alll as specified and directed by Engr -in-Charge. 141 Supply and fix in replacement Motor Guard( weather protection cover) made out of 18 gauge GI Sheet suitable upto 5 HP centrifugal/ mono block /Pressure pump setwith lifting handle and provision of suction /discharge pipeline Holes complete all as directed. 142 Dismantling & taking out defective parts of self priming recirculationpump set of capacity 3.5 HP and refixed after repairs / making complete serviceable by repairing / replacement of defective parts including tranportation to local work shop etc complete all as specified and directed by Engineer-in-charge. Note : -(i)Replacement of defective parts also included in the unit quoted rate.No extra payment shall be given for parts.(ii) only Rewinding of motor shall be given seperately. 143 M&L for rewinding of self priming recirculation pump of capacity 3.5 HP with same gauge of super enamelled copper winding wireafter cutting the burnt windings cleaning slots including insulating materials PVC sleeves insulation paper wooden stick etc complete all as specified and as directed by Engineer-in-charge 144 S&F in replacement of Phase sequence corrector suitable for 5 HP to 7.5 HP pump complete all as specified and as directed by Engineer-in-charge. 145 S&F in replacement of Phase sequence corrector suitable for 10 HP to 15 HP pump complete all as specified and as directed by Engineer-in-charge. 146 S&F in replacement of DOL startersuitable for 5 HP to 7.5 HP with relay 13-22 Amp complete all as specified and as directed by Engineer-in-charge. 147 S&F in replacement of starterfor submersible pump of capacity5 HP to 7.5 HP complete all as specified and as directed by Engineer-in-charge. 148 S&F in replacement of starterfor submersible pump of capacityupto 4 HP complete all as specified and as directed by Engineer-in-charge. 149 Disconnecting & dismantling of pump set from the foundation breaking the existing defective PCC foundation in any size, shape M&L for PCC 1:2:4 type B-2 using 12.5 mm graded aggregate for foundation of any size of motor pump set from 50 HP to 75 HP capacity pump set and fitting pumping set in position with base frame painted with synthetic enamel black paint complete all as specified and as directed by Engineer-in-charge 150 Material and labour for scrubbing out the rust deposited on the surface of centrifugal/Monoblock pump set of capacity 50 to 75 HP including its base frame and preparing for applying paint and apply one coat of redoxide primer and two coat of synthetic enamel paint and marking SM /MES Number complete all as specified and directed. 151 Material and labour for scrubbing out the rust deposited on the surface of centrifugal /Monoblock pump set of capacity 5 to 20 HP pump set including its base frame and preparing for applying paint and apply one coat of redoxide primer and two coat of synthetic enamel paint and marking SM /MES Numbercomplete all as specified and directed. 152 M&L in replacement of Ladder for OHT/ UG sump with square bar,angle iron,channel, Flat Iron and etc welding, drilling, cutting with one primer coat, one under coat and one finishing coat of paint complete all as specified and directed by Engineer in charge. 153 Material and labour for scrubbing out the rust deposited on the surface of water header 12 mtr long including all connecterd inlet and outlet pipesand preparing for applying paint and apply one coat of redoxide primer and two coat of synthetic enamel paint complete all as specified and directed . 154 S&F in replacement of MCCB 400 Amps 4 pole 415 volts 3 phase 50 Hz,Ics=100%Icu , breaking capacity 36 KAcomplete all as specified and directed. 155 S&F in replacement of MCCB 200 Amps 3 pole 415 volts 3 phase 50 Hz ,Ics=100%Icu, breaking capacity35 KA complete all as specified and directed. 156 S&F in replacement of MCCB 160 Amps3 pole 415 volts 3 phase 50 Hz ,Ics=100%Icu, breaking capacity 35 KA complete all as specified and directed. 157 Supply & fix in replacement of MCCB 100 amps 3 pole 25 KA 415 volts 50 Hz,,Ics=100%Icu complete all as specified and as directed by Engineer-in-charge. 158 Supply & fix in replacement of MCCB 125 amps 3 pole 16 KA 415 volts 50 Hz ,Ics=100%Icu complete all as specified and as directed by Engineer-in-charge. 159 Supply & fix in replacement of MCCB 63 amps 3 pole 16 KA 415 volts 50 Hz, Ics=100%Icu complete all as specified and as directed by Engineer-in-charge. 160 Supply & fix MCB TP 415 volt AC of capacity 63 amps complete all as specified and as directed by Engineer-in-charge. 161 Supply & fix MCB SPN of capacity 32 amps complete all as specified and as directed by Engineer-in-charge. 162 S&F in replacement of 3 pole power contactorMNX 50 to 110 or ML-4 with NO/NC block as required at site complete all as specified and directed. 163 S&F in replacement of 3 pole power contactor MNX 40 to 45/ML-3with NO/NC block as required at site complete all as specified and directed. 164 S&F in replacement of 3 pole power contactorMNX 25 to 32 /ML-2 with NO/NC block as required at site complete all as specified and directed. 165 S&F in replacement of 3 pole power contactorMNX upto 18/ML-1.5 with NO/NC block as required at site complete all as specified and directed. 166 Supply & fix Electronic overload relay (Manual reset) relayrange 9-15 amp suitable for direct mounting complete all as specified and as directed by Engineer-in-charge. 167 All as per item no 166.00 but for relay range 28-42 amp 168 All as per item no 166.00 but for relay range 45-75amp 169 All as per item no 166.00 but for relay range 66-110 amp 170 Supply and fix in replacement electronic timer ET-100 240V/415V complete all as specified and as directed by Engineer-in-charge. 171 Supply and fix in replacement amp meter 96 Sqmm digital type 0-100 amps complete all as specified and directed. 172 Supply and fix in replacement volt meter 0-500 volts 96 sqmm digital type complete all as specified and directed. 173 S&F in replacement of dial type FM-1 / QT daily timer one day 24 hrs 240 volt AC complete all as specified and directed. 174 S&F in repair CT 30/5 to 200/5 complete all as specified and directed. 175 S&F in repair indicating light with bulb set of three complete all as specified and directed. 176 S&F in repair PVC copper stranded conductor cable size 16 Sqmm multi stranded single core(3 runs with color coding) 1100 volt grade including copper thimble connecting from panel and motor complete all as specified and directed by Engineer-in-charge. 177 S&F in repair PVC copper stranded conductor cable size 25 Sqmm multi stranded single core(3 runs with color coding) 1100 volt grade including copper thimble connecting from panel and motor complete all as specified and directed by Engineer-in-charge. 178 S&F single phase preventor type VSP-D2 415 volts AC complete all as specified and directed. 179 Supply & fix of monoblock pump single phase 3 HP capacity 240Volts, 50 Hz AC including fitting in given location with GI fittings and electrical connections with control wire complete all as specified and directed by Engineer -in- Charge. 180 Supply & fix of monoblock pump single phase 1 HP capacity 240Volts, 50 Hz AC including fitting in given location with GI fittings and electrical connections with control wire complete all as specified and directed by Engineer -in- Charge. 181 M&L for attending of water supply complaints for any leakage/blockage in GI pipe lines of size 20mm/25mm bore taking up serviceable/unserviceable GI water pipe lines all fittings/fixtures from trench including supply and laying GI tubing 20mm/25mm bore up to 1 mtr length (max) including necesssary cutting, threading and replacement of unserviceable GI fittings such as GI socket /Nipple/union socket / Tee /reducer etc.of size 20mm/25mm including necessary excavation and earth work up to 1 mtr length to repair the leakage / clearing the blockage in the pipe line and testing on completion on ground/wall/floor/roof of the bldg .Note:- GI fittings ,upto 1 mtr length pipe,excavation,returning filling and removalrequired at site also included in the unit quoted rate . 182 All as per item No 181.00 here-in before but of size 40mm /50mm bore GI pipe line 183 All as per item No 181.00 here-in before but of size 80mm /100mm bore GI/CI pipe line 184 Supply and fix in replacementDecrin dozing pump 100 PSI40 GPD Capacity complete all as specified and directed. 185 Supply and fixin replacement FRP TANK suitable for Chlorine dozing system of Capacity 100 LTR with level gauge with agitator Motor ,connection shaft and mixing blade complete 186 Supply in replacement connection pipe suitable for connecting to decrin dosing pump to Header(8 mm internal dia) 187 Supplyand fix in replacement of injector Nozzle of Decrin dozing pump 188 Supply and fix in replacement of PVC pipe 25mm dia 189 S&F in replacement of constant voltage driver of capacity 10 amps 12 Volt complete all as specified and as directed by Engineer-in-charge 190 S&F in replacement of constant voltage driver of capacity 15 amps 24 Voltcomplete all as specified and as directed by Engineer-in-charge 191 S&F in replacement under water light 12 volt LED type 3 watt IP 67 for fountain including angle adjustable stand required for fixing complete allas specified and directed. 192 S&F in replacement under water light 12 volt LED type 5 watt IP 67 for fountain including angle adjustable stand required for fixing complete allas specified and directed. 193 S&F in replacement under water light 24 volt LED type 6 watt multicolour (7 colour) IP 67 for fountain including angle adjustable stand required for fixing complete allas specified and directed. 194 Dismantling of water fountain ring made out of MS / GI pipe of 40 to 80mm dia and refixing the same in its original position after cleaning / repairing like welding work etc complete all as specified and directed by Engineer-in-charge 195 Dismantling of Blocked nozzles fixed on various fountain and refixing after cleaning / servicing and setting by trial and error complete all as specified and as directed by Engineer-in-charge 196 S&F in replacement fountain nozzle (adjustable) of size 12mm /15mm/20mm/25mm complete all as specified and directed. 197 S&F in replacement of Rubber packing ring suitable for under water light fittings complete all as specified and as directed by Engineer-in-charge 198 Supply & fixing in replacement wire netting of stainless steel wire 1.4mm dia size of mesh 12mm fixed to bend pipe dia 100mm to 200mm fixed with GI clamp including nuts and bolts etc complete all as specified and directed by Engineer-in-charge 199 S&F in replacement of angle adjustable stand for luminaries made of SS-304 materials as per Sample for fountains complete all as specified and directed. 200 Scrapping of old painting from complete fountain assembly made of MS / GI / Steel pipe and applying two coats of approved synthetic enamelled paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-charge 201 M&L for cleaning of fountain, water body complete with cleaning solutions removing all the sludge /foreign particles from the sump of fountain complete all as specified and as directed by Engineer-in-charge 202 M&L for GI clamps of 32mmx5mm complete with screw 50mm long x 6mm dia complete with drilling the hole with drilling machine with rawl plugs / wooden gutties for fixing / clamping the GI pipes suitable for 50/40mm dia at a interval 01 mtr Each complete by providing necessary scafolding upto the height of 15 mtrs complete all as specified and directed by Engineer-in-charge 203 Supply and fix in replacement PVC water tank cylendrical shape3 layer of capacity 5000 Ltrs complete all as specified and directed. 204 Supply and fix in replacement PVC water tank cylendrical shape 3 layer of capacity 2000 Ltrs complete all as specified and directed. 205 Supply and fix in replacement PVC water tank cylendrical shape 3 layer of capacity 1000 Ltrs complete all as specified and directed. 206 M&L for chemical and bacteriological analysis and potability of water obtained from Delhi Jal Board & various bore wells fromApproved Micro Engineering and Testing Lab and submitting the report in duplicate complete all as specified and as directed by Engineer-in-charge 207 Cleaning of under ground / semi under ground water storage sump of capacity 100000 gallons by tank clean process which is folowing :- (a) Mechanised removal of all remaining dirty water by high capacity submersible pump set (b) Removal of sludge by vacuum operated GeRMan pump (c) Cleaning of walls, ceiling and bottom of tank by GeRMan made high pressure rotary jet 120 bars pressure (d) Removal of all dirty particle by industrial wet vacuum cleaner leaving the tank 99.9% physically cleaned (e) Sterlization of tank by Eco-Friendly biodegradable and highly effective against all pathogens (f) Sterlization of tank atmosphere by industrial UV radiator leaving the tank complete sterlite by Spealized Method. 208 All as per above item No 207.00 here-in-before but underground water storage sump of capacity 2x50000 gallons having two compartments 209 All as per above item No 207.00 here-in-before butsemi-underground water storage sump of capacity 50000 gallons having two compartments 210 All as per above item No 207.00 here-in-before but underground water storage sump of capacity 20000 gallons complete 211 All as per above item No 207.00 here-in-before but underground water storage sump of capacity 35000 gallonscomplete 212 All as per above item No 207.00 here-in-before but underground water storage sump of capacity 10000 gallons complete 213 All as per above item No 207.00 here-in-before but over head water tank of upto 45 mtr staging (Height of OH Tank) of capacity 100000 gallonscomplete all as specified and directed by Engr-in-Charge.NOTE:- All the sluge materials / fungs removed from the underground sump / semi underground sump and over head tanks will be removed from the site to a distance not exceeding 50 mtr and all underground sump / semi underground sump and overhead tanks will be cleaned in all respect upto 3 mtr around the water tanks. The cost of the same shall be deemed included in the respective items. All T&P required for the cleaning of tanks / sumps will be arranged by the contractor. 214 Supply only TCCA-90 (Trichloro cynuric acid) 215 Supply only Soda Ash 216 Supply only Alum 217 Supply only Copper Sulphate (CuSO4) 218 Supply only HCL (Acid) 219 Supply and fixing in replacement of under water light fitting LED 20 watt ,IP 67, 12 Volt round type as per shifting for swimming poolcomplete including water proofing joint complete all asspecified and directed. 220 Supply and fix in replacementmulti fuction valve size 100 / 80 / 63 mm (Filter, Rinse, Waste, Close, Backwash, & Recirculate option in built) including necessary fittings required at site to match with the existing andconnected to as per exisiting sizeand Make for swimming pool complete all as directed . 221 Supply and replacement of suction sweeper PVC pipe 50mm dia complete all as specified and directed. 222 Supply only Test kit for residual chlorine & Ph including necessary chemicals of 200 ml Each complete all as specified and directed. 223 S&F in replacement & jointing in position of unserviceable UPVC pipe confoRMing, to IS: 4985:2000 and suitable for the respective working pressures with all fittings and accessories e.g coupling, tees, bends, reducers, screwed adapters, flanged tails pieces etc. jointing as per manufacturers insturctions , including excavation, earth work (45cm width and 30 cm depth) in any type of soil / rock complete all as directed . (a)UPVC pipe 90 mm OD-6 Kg/cm² 224 All as per item No 223 here in before but UPVC pipe 75 mm OD-6 Kg/cm² 225 All as per item No 223 here in before butUPVC pipe 63 mm OD-6 Kg/cm² 226 All as per item No 223 here in before but UPVC pipe 50 mm OD-6 Kg/cm² 227 Supply & fixing in replacement of unserviceable Sprinkler gear driven 1 pop upSprinkler with heavy duty plastic rubber cover with triple nozzle configuration-ensure even distribution of water.2NI adjustable or continuous rotation -provide a full range of adjustment from 40 to 360 degree vandal resistant clutch with auto reset . It has tranjectory angle of 26 degree and part circle adjustment from 40 degree -345 degree.It is capable of delivering 19.3 LPM-110.5 LPM with dia of coverage from 12.5-2.5m at 2.0-4 bar. 228 S&F in replacement of unserviceable 1 Swing Joint. 229 S&F in replacement of unserviceable Metallic services saddle 3/4 230 S&F in replacement of unserviceable Valves box 12 Rectangular Valve box with cover.The valve boxes shall be high strength , high density polyethelene constructed material.It should be UV stablizer with anti oxidants, resistant to moisture. 231 Supply and fixing in replacement of complete inner filter assembly suitable for 57 m3/hr flow rate, working pressure 2.5 Kg/Sqcm and filtering velocity 50m3/hr/m2 of the 1200mm dia pressure filterincluding opening the pressure filter 1200mm dia Make-Pentair installed at swimming pool equipment room completeand testing for leakage for proper functioningcomplete all as directed 232 Opening the pressure filter 1200mm dia Make-Pentair installed at swimming pool equipment room removing the old filter media, removing all the scaling deposited on the surface area of filter assembly by using wire brush and cleaning the filter with HCL, refilling new filter media of various silica grade as required at site, re-assembling the filter assembly and testing for leakage for proper functioning and testing complete all as directed 233 Taking up cast iron water mains of 250mm bore including all fittings with spigot and socket end and lead joints including burning out joints and recovering lead complete all as specified and as directed by Engineer-in-charge 234 All as per item No 233 here-in-before but 200mm bore 235 All as per item No 233 here-in-before but 150 mm bore 236 All as per item no 233 here in before but 100mm dia bore 237 All as per item no 233 here in before but 80mm dia bore 238 Supply and laying of DI pipes of grade K-9 with spigot and socketted ends centrifugally cast in any length sizeof 250mm dia bore complete laid in trenches all as specified and as directed by Engineer-in-charge 239 All as per item no 238 as above but DI Pipeof 200mm dia bore 240 All as per item no 238 as above but DI Pipeof 150mm dia bore 241 All as per item no 238 as above but DI Pipeof 100mm dia bore 242 All as per item no 238 as above but DI Pipeof 80mm dia bore 243 Cutting to DI pipes of 250mm bore before laying in position for insertion of new tees, branches, bend and new connection etc complete all as specified and as directed by Engineer-in-charge. 244 All as per item no 243 as above but DI Pipe of size 200mm dia bore 245 All as per item no 243 as above but DI Pipe of size upto 150mm dia bore 246 Supply and fixingand testing of DI fittings for spigot and socket pipes such as bends (any type radius and angle) tapers any type (straight, bend, increasing, descreasing or double socket etc), Tee piece single branch, Y junction, double branch cross (all sockets or socket and spigot) collors, caps and plugs including dewatering suitable for pipes upto 250 mm bore complete all as specified and as directed by engr in charge. NOTE : Excavation earth work in any type of soil/Rockand jointing of pipes shall be measured and paid seperately. 247 Supply and fixing250mm dia tyton rubber gasket ,packing and rings complete all as specified and directed 248 Supply and fixing200mm dia tyton rubber gasket ,packing and rings complete all as specified and directed 249 Supply and fixing150mm dia tyton rubber gasket ,packing and rings complete all as specified and directed 250 Supply and fixing100mm dia tyton rubber gasket ,packing and rings complete all as specified and directed 251 Supply and fixing80mm dia tyton rubber gasket ,packing and rings complete all as specified and directed 252 Supplying, laying, jointing, welding & testing MS Pipe of size 100mm dia bore (Heavy duty classC),as per IS 3589 (1981) thickness 5.4 mm suitable for welded joints and flanged joints as per site requirement including painting with two coats of anti corrosive paint ,laid in trenches/bore or laying on floors for connections to centrifugal pump sets for suction/delivery and to connected outgoing water main pipe line complete including welding works and taking down old unserviceable MS pipe complete all as specified and directed. 253 All as per above item No 252.00 here-in-before but 150mm dia 254 Supply and fixingand testing ofMS Pipe bend of size 150mm dia bore (Heavy duty classC),as per IS 3589 (1981) thickness 5.4 mm complete all as specified and as directed by engr in charge. 255 All as per above item No 254.00 here-in-before but 100mm bore 256 All as per above item No 254.00 here-in-before but 80mm bore 257 Supply and fixingand testing ofMS Pipe Tee of size 150mm dia bore (Heavy duty classC),as per IS 3589 (1981) thickness 5.4 mm complete all as specified and as directed by engr in charge.
Contract Date : 04 Feb, 2026   |   Contract Value : 26.75 Lakhs
BRR : 7822844 REPAIR/ MAINT OF PUMP, MOTOR, STARTER, DOZING SYSTEM, SWIMMING POOL COMPRESSOR, RAISING MAIN, GATE VALVE, PERIODICAL CLEANING OF TANKS & OTHER MISC WORKS AT AFTC, 2 DC AREA & AFS JALAHALLI EAST WEST AREA; M&L for taking down defective centrifugal pump set 100 HP capacity by disconnecting the pump from motor after unscrewing nuts/ bolts of coupling, foundation, suction pipe delivery pipes and shifting of pump to workshop for repair/ servicing, comprising strip opening of pump, replacement of any defective parts, carrying out necessary lath work, re-assembling and shifting from workshop to site, re-installation at same location as directed by Engr-in-Charge, testing on full load capacity at least for 8 hrs, complete all as specified and as directed. Note :-(a)The spares shall be measured and paid seperately in the relevent items given below.(b) Cost of labour for replacement of spares and transportation are deemed to be included in the quoted rate. (c)The pumpset shall be spared for one week for repair from the date of complaint given by AGE/ JE E/M regarding breakdown. Thecontactor is responsible for making alternate arrangement of pump set in case of time required more than one week.(d)In case services affected due to delay in repair of pump set, a penalty @ Rs 1000 per day will be levied from the contactor.(e)Please note that this penalty is exclusively other than the condition 67 of IAFW-2249 and shall be treated as interim condition of the contract.(f)The decision of the Accepting Officer in this regard shall be final and binding. 2 Supply only Ball bearing suitable for 100 HP capacity motor pump as per manufacturers design complete all as specified and as directed.Make : Tata/SKF/NBC 3 Supply only coupling Rubber Bush suitable for 100 HP capacity motor pump as per manufacturers design complete all as specified and as directed. 4 Supply only split casing gaskets suitable for 100 HP capacity motor pump as per manufacturers design complete all as specified and as directed. 5 Supply only shaft sleeves suitable for 100 HP capacity motor pump as per manufacturers design complete all as specified and as directed. 6 Supply only coupling bolt with nuts suitable for 100 HP capacity motor pump as per manufacturers design complete all as specified and as directed. 7 Supply only water seal suitable for 100 HP capacity motor pump as per manufacturers design complete all as specified and as directed. 8 Supply only Air cock grease nipple suitable for 100 HP capacity motor pump as per manufacturers design complete all as specified and as directed. 9 Remetaling of shaft, turning, grinding as per the required size and polishing including provision of neck rings of impellers suitable for 100 HP capacity motor pump as per manufacturers design complete all as specified and as directed. 10 Supply only bronze impeller suitable for 100 HPcapacity motor pump as per manufacturers design complete all as specified and as directed. 11 M&Lfor suitable size of gland packing for 100 HP pump set as per manufacturers design complete all as specified and as directed. 12 Supply & fix in replacement of 3 Pole power contactor AC 415 V 160 Amps ,AC3 ( inductive load ) type with Aux contact 2 NO + 2 NC50 Hz Model No. as per existing framesuitable for 100 HP Pump sets complete all as specified and as directed.Make : L & T / Indo Asian /Schneider 13 M & L for servicing of starter by checking and servicing the contactor coil , over load relay coiland any other parts and replacement the burnt out wiring including any modification to pump starter panel by welding,cutting , grinding ,drillingtesting the panel complete all as specified and directedfor the100 HP capacity pump setsNotes :-(i) Minor spare parts such as nuts,bolts ,washers ,indicator lamps , start,stop push button and suitable size of copper wire are deemed to be include in quoted rate. 14 Supply & fix in replacement adjustable CT/Direct operated thermal over load relay 105 to 156 A for 100 HP motor 3 phase 415v , 3 pole , with single phase protection including CTs complete all as specified and as directed.Make : L & T / Indo Asian /Schneider 15 M&L for rewinding ofsquirrel cage induction electrical motor , 3 phase, 415 volts with suitable size of copper enameled winding wire and insulating materials incl disconnecting all electrical connections ,decoupling from pump,taking down the motor from foundation , cleaning and varnishing the stator & rotor winding, heating and drying, replacement of burnt terminals, greasing to bearings, re-assembling the motor and refixing of motor on the foundation by using new nut, bolts and washers, coupling with pump,checking alignment connecting all electrical connections,checking the vibrations, RPM and testing on full load complete all as specified and directed for 100HPmotor capacity. 16 M&L for taking down defective centrifugal pump set 60 HP capacity by disconnecting the pump from motor after unscrewing nuts/ bolts of coupling, foundation, suction pipe delivery pipes and shifting of pump to workshop for repair/ servicing, comprising strip opening of pump, replacement of any defective parts, carrying out necessary lath work, re-assembling and shifting from workshop to site, re-installation at same location as directed by Engr-in-Charge, testing on full load capacity at least for 8 hrs, complete all as specified and as directed. Note :-(a)The spares shall be measured and paid seperately in the relevent items given below.(b) Cost of labour for replacement of spares and transportation are deemed to be included in the quoted rate. (c)The pumpset shall be spared for one week for repair from the date of complaint given by AGE/ JE E/M regarding breakdown. Thecontactor is responsible for making alternate arrangement of pump set in case of time required more than one week.(d)In case services affected due to delay in repair of pump set, a penalty @ Rs 1000 per day will be levied from the contactor.(e)Please note that this penalty is exclusively other than the condition 67 of IAFW-2249 and shall be treated as interim condition of the contract.(f)The decision of the Accepting Officer in this regard shall be final and binding. 17 Supply only Ball bearing suitable for 60 HP capacity motor pump as per manufacturers design complete all as specified and as directed.Make : Tata/SKF/NBC 18 Supply only coupling Rubber Bush suitable for 60 HP capacity motor pump as per manufacturers design complete all as specified and as directed. 19 Supply only coupling bolt with nuts suitable for 60 HP capacity motor pump as per manufacturers design complete all as specified and as directed. 20 Supply only shaft sleeves suitable for 60 HP capacity motor pump as per manufacturers design complete all as specified and as directed. 21 Supply only split casing gaskets suitable for 60 HP capacity motor pump as per manufacturers design complete all as specified and as directed. 22 Supply only water seal suitable for 60 HP capacity motor pump as per manufacturers design complete all as specified and as directed. 23 Supply only Air cock grease nipple suitable for 60 HP capacity motor pump as per manufacturers design complete all as specified and as directed. 24 Remetaling of shaft, turning, grinding as per the required size and polishing including provision of neck rings of impellers suitable for 60 HP capacity motor pump as per manufacturers design complete all as specified and as directed. 25 Supply only bronze impeller suitable for 60 HPcapacity motor pump as per manufacturers design complete all as specified and as directed. 26 Supply and fix in replacement of mechanical flexible UT tyre rubber coupling suitable for 60 HP centrifugal pump set with cast iron flange, natural rubber coupler, mild steel clamping ring, high tensile strength Grade suitable size of Hex bolts, including aligning motor - centrifugal pump with a tolerance of +- 4mm, testing complete all as specified and directed. 27 M&Lfor suitable size of gland packing for 60 HP pump set as per manufacturers design complete all as specified and as directed. 28 M & L for servicing of starter by checking and servicing the contactor coil , over load relay coiland any other parts and replacement the burnt out wiring including any modification to pump starter panel by welding,cutting , grinding ,drillingtesting the panel complete all as specified and directedfor the60 HP capacity pump setsNotes :-(i) Minor spare parts such as nuts,bolts ,washers ,indicator lamps , start,stop push button and suitable size of copper wire are deemed to be included in quoted rate. 29 Supply & fix in replacement of 3 Pole power contactor AC 415 V AC3 ( inductive load ) type 100 Amps, AC3 type 2 NO + 2 NC50 Hz Model No. as per existing frame suitable for 60 HP Pump sets complete all as specified and as directed.Make : L & T / Indo Asian /Schneider 30 Supply & fix in replacement adjustable CT/Direct operated thermal over load relay75 to 110 A for 60 HP motor 3 phase 415v , 3 pole , with single phase protection including CTs complete all as specified and as directed.Make : L & T / Indo Asian /Schneider 31 Supply & fix in replacementSingle phase preventer for motor in the existing panel board with new one at water supply installations complete all as specified and as directed. 32 Supply & fix in replacement Star Delta timer 0-30/60 sec complete all as specified and as directed. 33 M&L for rewinding ofsquirrel cage induction electrical motor , 3 phase, 415 volts with suitable size of copper enameled winding wire and insulating materials incl disconnecting all electrical connections ,decoupling from pump,taking down the motor from foundation , cleaning and varnishing the stator & rotor winding, heating and drying, replacement of burnt terminals, greasing to bearings, re-assembling the motor and refixing of motor on the foundation by using new nut, bolts and washers, coupling with pump,checking alignment connecting all electrical connections,checking the vibrations, RPM and testing on full load complete all as specified and directed for 60 HPmotor capacity. 34 Taking down defective centrifugal pump set 25 HP by disconnecting the pump from motor after unscrewing nuts/ bolts of coupling, foundation, suction pipe delivery pipes and shifting of pump to workshop for repair/ servicing, comprising strip opening of pump, replacement of any defective parts, carrying out necessary lathe work, re-assembling and shifting from workshop to site, re-installation at location as directed by Engr-in-Charge, testing on full load capacity at least for 8 hrs, complete all as specified and as directed. Note :- (a)The spares shall be measured and paid seperately in the relevent items given below.(b) Cost of labour for replacement of spares and transportation are deemed to be incl in the quoted rate. (c)The pumpset shall be spared for one week for repair from the date of complaint given by AGE/ JE E/M regarding breakdown. Thecontactor is responsible for making alternate arrangement of pump set in case of time required more than one week.(d)In case services affected due to delay in repair of pump set, a penalty @ Rs 500 per day will be levied from the contactor.(e)Please note that this penalty is exclusively other then the condition 67 of IAFW-2249 and shall be treated as interim condition of the contract.(f)The decision of the Accepting Officer in this regard shall be final and binding. 35 Supply only Ball bearing suitable for 25 HP motor pump as per manufacturers design complete all as specified and as directed.Make : Tata/SKF/NBC 36 Supply only split casing gaskets suitable for 25 HP motor pump as per manufacturers design complete all as specified and as directed. 37 Supply only Air cock grease nipple suitable for 25 HP motor pump as per manufacturers design complete all as specified and as directed. 38 Supply only water seal suitable for 25 HP motor pump as per manufacturers design complete all as specified and as directed. 39 Supply only coupling bolt with nuts suitable for 25 HP motor pump as per manufacturers design complete all as specified and as directed. 40 Supply only coupling Rubber Bush suitable for 25HP motor pump as per manufacturers design complete all as specified and as directed. 41 Supply only shaft sleeves suitable for 25 HP motor pump as per manufacturers design complete all as specified and as directed. 42 Supply only bronze impeller suitable for 25 HP motor pump as per manufacturers design complete all as specified and as directed. 43 Remetaling of shaft, turning, grinding as per the required size and polishing including provision of neck rings of impellers suitable for 25 HP motor pump as per manufacturers design complete all as specified and as directed. 44 M&Lfor suitable size of gland packing for 25 HP pump set as per manufacturers design complete all as specified and as directed. 45 Supply & fix in replacement adjustable CT/Direct operated thermal over load relay30 to 43 A for 25 HP motor 3 phase 415v , 3 pole , with single phase protection including CTs complete all as specified and as directed.Make : L & T / Indo Asian /Schneider 46 Supply & fix in replacement of3 Pole power contactor AC 415 V AC3 ( inductive load ) type 40 Amps with add on aux contact 2 NO + 2 NC50 Hz Model No. as per existing framesuitable for 25 HP Pump set complete all as specified and as directed.Make : L & T / Indo Asian /Schneider 47 M & L for servicing of starter by checking and servicing the contactor coil , over load relay coiland any other parts and replacement the burnt out wiring including any modification to pump starter panel by welding,cutting , grinding ,drillingtesting the panel complete all as specified and directedthe25 HP capacity pump setsNotes :-(i) Minor spare parts such as nuts,bolts ,washers ,indicator lamps , start,stop push button and suitable size of copper wire are deemed to be included in quoted rate. 48 M&L for rewinding ofsquirrel cage induction electrical motor , 3 phase, 415 volts with suitable size of copper enameled winding wire and insulating materials incl disconnecting all electrical connections ,decoupling from pump,taking down the motor from foundation , cleaning and varnishing the stator & rotor winding, heating and drying, replacement of burnt terminals, greasing to bearings, re-assembling the motor and refixing of motor on the foundation by using new nut, bolts and washers, coupling with pump,checking alignment connecting all electrical connections,checking the vibrations, RPM and testing on full load complete all as specified and directed for 25 HPmotor capacity. 49 Supply and fixing in repair of3 phase star delta pump starter suitable for 25 HP centrifugal pump with over load relay of suitable current rating,timer relay ,single phase preventor fixing in existing enclosure including all connected accessories complete all as specified and directed Make : L&T/Indoasian/Schenider/Havells 50 Supply and fix as in repair 4 Pole MCCB ,415 volts,fixed type ,160 Amp, 50 Hz, with rupturing capacity 25 KA in theexisting pump starter panel including connecting up incoming/out going cables with suitable lugs and testing complete all as specified and as directed. Make: Indoasian/L&T/ Legrand 51 Taking down and relaying of existingDI water pipe lines of size 300 mm bore but of any type including all fittings after removal of scaling, cleaning and flushing etc complete all as specified and directed.Note:Excavation & earthwork shall be measured & paid seperately 52 Taking down and relaying of existingDI water pipe lines of size 200 mm bore but of any type includings all fittings after removal of scaling, cleaning and flushing etc complete all as specified and directed.Note:Excavation & earthwork shall be measured & paid seperately 53 M&L as in replacement for Ductile Iron Pipe (DI Pipes), ISI marked, Class K-7, 300 mm dia laid in trenches including jointing material such as EPDM Rubber Gasket and suitable type of grease etc complete all as specified and directed.Note :- DI fitting/special shall be measured and paid separately.Note:Excavation & earthwork shall be measured & paid seperately 54 Supply and fixing in replacement Sluice valve of size 300 mm dia Cl body, both ends flanged duly drilled, ISI marked with IS-14846-2000, PN-1.6 having Stainless Steel spindle and check nut including operating wheel, fixing with new nuts, bolts, washers and rubber insertion/packing complete all specified and directed 55 Material and Labour for dismantling the brassspindle from 300 mm dia bore sluice valves in various locations and reconditioning the sluice valve by replacing SS/bronze spindle, spindle nuts with brass ring, gland nuts complete all as specified and as directed. 56 Material and Labour for gland packing in leaking Sluice Valves of 300 mm dia size Complete including replacing/tightening the existing bolts and nuts etc. complete all as directed . 57 Cutting the existing broken / cracked CI/DI/GI/Asbestos Cement Pipe line of size upto 300mm dia, by dewatering the leakage water from site and removing the old pipe line and addition / alteration to pipe by providing new pipe,welding,bending,grinding,including all accessories such as tee,elbow,collar etc , and ensure no leakage with pressure test complete all as specified and directed , Note : Pipes and mechanical collar shall be measured and paid seperately 58 M&L for specials fittings suitable for Cast iron / ductile iron /Asbestos cement pipe made out of MS Plate of 12 mm thick complete with mechanical/detachable type arrangement as per site requirementwith MS bolts and nuts of suitable size and MS sheet fabricated to required dia of pipe for prepration of collar/flange, on any pipe leak or cracks of pipe for arresting the leakage complete including rubber ring, packing rubber sheet,set of two collar rings of size 300 mm borecomplete all as specified and as directed. 59 M&L as in replacement for Ductile Iron Pipe (DI Pipes), ISI marked, Class K-7, 200 mm dia laid in trenches including jointing material such as EPDM Rubber Gasket and suitable type of grease etc complete all as specified and directed.Note :- (i)DI fitting/special shall be measured and paid separately. (ii)Excavation & earthwork shall be measured & paid seperately 60 S&F in replacementfoot valve (confirming to IS-4038) cast iron of size 200 mm bore including rubber insertion, packing material, nuts, bolts, and washer with suitable new one all as specified and directed. 61 Supply and fixing in replacement Non return valve (confirming to IS-5312) (NRV) of size 200 mm ISI marked, CIbody suitable for 200 mm dia pipe line complete all specified and directed 62 Supply and fix replacement of U/S leather packing suitable for foot valve 150 to 200 mm dia, suction pipe flanged connected to pumpsets including replacement ofnuts and bolts etc all as specified and directed 63 Supply and fixing in replacement Sluice valve of size 200 mm dia Cl body, both ends flanged duly drilled, ISI marked with IS-14846-2000, PN-1.6 having Stainless Steel spindle and check nut including operating wheel, fixing with new nuts, bolts, washers and rubber insertion/packing complete all specified and directed 64 Material and Labour for dismantling the brassspindle from 200 mm dia bore sluice valves in various locations and reconditioning the sluice valve by replacing SS/bronze spindle, spindle nuts with brass ring, gland nuts complete all as specified and as directed. 65 Material and Labour for gland packing in leaking Sluice Valves of 200 mm dia size Complete including replacing/tightening the existing bolts and nuts etc. complete all as directed . 66 Material & Labour as in repair for Construction ofValve pit having inner dimensions 1200 mm x 1200 mm x 1200 mm with foundation PCC 1:4:8 type D2 using 40mm grade stone aggregate, brick work with sub class B old size bricks built in Cement mortar 1:6, PCC 1:2:4 type B1 using 20mm stone aggregate for Coping, 15 mm thick rendering plaster in CM 1:4 inluding MS cover with locking arrangement all as specified and as directed.Note :- MS work as in chamber cover shall be measured and paid separately under relevant item of this schedule. 67 Cutting the existing broken / cracked CI/DI/GI/Asbestos Cement Pipe line of size upto 200mm dia, by dewatering the lekage water from site and removing the old pipe line and addition / alteration to pipe by providing new pipe,welding,bending,grinding,including all accessories such as tee,elbow,collar etc , and ensure no leakage with pressure test complete all as specified and as directed. Note : Pipes and mechanical collar shall be measured and paid seperately 68 M&L for specials fittings suitable for Cast iron / ductile iron /Asbestos cement pipe made out of MS Plate of 12 mm thick complete with mechanical/detachable type arrangement as per site requirementwith MS bolts and nuts of suitable size and MS sheet fabricated to required dia of pipe for prepration of collar/flange, on any pipe leak or cracks of pipe for arresting the leakage complete including rubber ring, packing rubber sheet,set of two collar rings of size 200 mm borecomplete all as specified and as directed. 69 Clearing the bushes trunk girth not exceeding 10 .00 cm and area around valve chambers upto 1.0 mtrs and depositing at a distance not exceeding 50 mtrs from starting point complete all as specified and directed 70 Demolition of Brickwork or precast concrete block walling including wall quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone work and concrete articles built in cement mortar complete all as specified or directed. 71 M&L for Pre-cast cement concrete block masonry in PCC (1:3:6) type C-1 using 20mm grade stone aggregate with solid blocks, exc.10 cm in width and setting in cement mortor 1 : 4, complete, in walls all as specified and directed. 72 Over hauling and repair to Chemical Dosing Pump Granual based chloronome plants at Range pump houseby cleaning the FRP 150 Ltrs Tank, and cleaning of filters and NRV , checking and cleaning the delivery pipe line for chocking , cleaning of chlorination plant and maintainig properly including checking the level of oil in the gauge and topping up as and when required, checking the glands and maintain the plant in all respect and replacement of minor spare for smooth functioning of Chlorination Plant all as directed by Engineer in charge. Note:- The unit rate quoted shall be deemed to include for the cost of replacement of minor spares such as O rings , nut/screws,washers,bolt, cleaning waste , toolsfor routine day to day maintenance and necessary servicing to keep the plants in running condition on all days includingSunday and holidays, Replacement of other major spares shall be measured and paid for separately under respective item of BOQ 73 All as per item No 72 but at E & ITI OH Tank complete all as specified and directed. 74 All as per item No 72 but at Double Tank complete all as specified and directed. 75 All as per item No 72 but at ETI OH Tank complete all as specified and directed. 76 Supply onlyO-tolodine chlorine solution in packing of 200ml bottle for testing of chlorine content in water 77 Supply onlyChlorine dosing pistonpump unit complete 78 Supply only Rubber ring for mixing chamber 79 Supply onlyPVC NRV set with glass ball for suction and delivery adopter 20 mm dia 80 Supply onlyTeflon gland square type 3 mm for smooth functioning of Chlorination plant 81 Supply only PVCdiaphram valve 25 mm dia heavy duty 82 Supply only Agitator mixing assembly with motor 83 Supply only Chlorine test kit with coloured sample Complete with all testing fitments and OT - solution in Rexene finished box Complete all as specified and as directed 84 Supply of calcium based high strength chlorination chemical for water in granular form chlorine concentration level having 65%-70% chlorine content packed in 45 Kg capacity in factory sealed HDPE Container superior quality suitable for treatment of drinking water complete all as specified and directed.Note:The material shall be delivered at watersupply installation as per direction of AGE E/M as & when required during the contract period. 85 Material and labourfor Attending day to day water supply service related complaintslike choking of rising main pipes of buildings, blockage in control valves/ float valves/ pipe fittings, etc, applying necessaryengineering efforts like dismantle of pipes and fittings to clean and remove blocking objects, descaling of pipes, re-fixing of pipes on wall, etc to restore the proper flow of water to service tanks all as specified and directed. 86 Note :- (a) The contractor has to attend above mentioned job in any location of AFTC, 2 DC and entire AFS jalahalli East and West area 87 (b)The service tanks are positioned on roof top of multi storied buildings upto three storey. Contractor is responsible to ensure that the labour employed should be equipped with safety items like industrial helmet, safety belt, extensible ladder of 40 feet length, plumbing and cuttings tools, etc. 88 (c) The cost of rethreading of GI pipes of 25mm dia and adding of new GI nipple of suitable length after rethreading is deemed to be included in the quoted rate. 89 (d) Due to shortage of water in the station, the repair work and testing required under this item need to be carried out during water supply distribution hours i.e. 5:30 AM to 7:30 AM. Nothing extra shall be permitted in this regard. 90 (e) The cost of repair to the damages of cemented surfaces/ external finishes/ metal clamps of rising pipes are also deemed to be included in the quoted rate. 91 (f)In case of any delay in attending the complaint more than 6 hrs after handing over routine/urgent complaints, the contractor shall be liable to pay the penalty as described in penalty clause given here as under. 92 (g)If the delay is more then 06 hrs period and the GE is not satisfied with the reason for delay then penalty at the rate of Rs 100/- per job shall be deducted from the dues of the contractor. Please note that this penalty is exclusively other then the condition 67 of IAFW - 2249 and shall be treated as interim condition of the contract and shall be enforce above as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt. 93 (h) The decision of the Accepting Officer in this regard shall be final and binding. 94 Supply and fix Nipple suitable for HDPE water tankof size 20 mm complete all as specified and as directed. 95 Supply and fix Nipple suitable for HDPE water tankof size 25 mm complete all as specified and as directed. 96 Supply and fix in repairs lids for polyethylene water storage tanks, threaded or hinged type as per existing incl PTMT nuts/binding wire suitable up to 1000Ltrs cap of tanks complete all as specified and directed by Engineer-in Charge 97 Supply and fix in replacement PVC Ball valve ISI marked high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed of size 20 mm complete all as specified and directed 98 Supply and fix of PVC water tank 500 ltrs capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I ,complete all as directed incl disconnecting existing tank of any description and any capacity complete. 99 Supply and fixingin repair 25 mm dia Unplasticiced PVC Pipes of pressure rating 10kgf/cm2including fittings like socket / union / Tee / Reducer / Nipple etc complete fixed to wall/ceilings/ in floors etc, complete all as specified and directed. 100 Supply and fixing in repair20 mm dia Unplasticiced PVC Pipes of pressure rating 10kgf/cm2including fittings like socket / union / Tee / Reducer / Nipple etc complete fixed to wall/ceilings/ in floors etc, complete all as specified and directed. 101 Supply and fixingin repair UPVC Gate Valve of size 25 mm dia , ISI marked complete all as specified and as directed. 102 Supply and fixingin repair UPVC Gate Valve of size 20 mm dia, ISI marked complete all as specified and as directed. 103 Supply and fixingin repair 20 mm dia Chlorinated PVC (CPVC) Pipes of pressure rating 10kgf/cm2including fittings like socket / union / Tee / Reducer / Nipple etc complete fixed to wall/ceilings/ in floors etc, complete all as specified and directed. 104 Supply and fixingin repair 25 mm dia Chlorinated PVC (CPVC) Pipes of pressure rating 10kgf/cm2including fittings like socket / union / Tee / Reducer / Nipple etc complete fixed to wall/ceilings/ in floors etc, complete all as specified and directed. 105 Supply and fixingin repair Chlorinated PVC Gate Valve of size 20 mm dia, ISI marked complete all as specified and as directed. 106 Supply and fixingin repair Chlorinated PVC Gate Valve of size 25 mm dia, ISI marked complete all as specified and as directed. 107 Supply and fix in repairs lids for polyethylene water storage tanks, threaded or hinged type as per existing incl PTMT nuts/binding wire suitable for1001 to 5000 Ltrs cap of tanks complete all as specified and directed by Engineer-in Charge 108 Supply and fix in replacement PVC Ball valve ISI marked high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed of size 25 mm complete all as specified and directed 109 Supply and fix of PVC water tank 1000 ltrs capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I ,complete all as directed incl disconnecting existing tank of any description and any capacity complete. 110 Taking down and relaying of existingserviceable GI tubing / connection in new or old positions including cleaning, cutting, threding all as directed, along with new GI fittings where ever replaced and required at site of size 40 to 50 mm bore complete all as specified directed. Note:Excavation & earthwork shall be measured & paid seperately 111 Taking down and relaying of existing serviceable GI tubing / connection in new or old positions including cleaning, cutting, threding all as directed, along with new GI fittings where ever replaced and required at site of size 25 mm bore complete all as specified directed. Note:Excavation & earthwork shall be measured & paid seperately 112 Taking down and relaying of existingserviceable GI tubing / connection in new or old positions including cleaning, cutting, threding all as directed, along with new GI fittings where ever replaced and required at site of size 20 mm bore complete all as specified directed. Note:Excavation & earthwork shall be measured & paid seperately 113 Taking down and relaying of existingserviceable GI tubing / connection in new or old positions including cleaning, cutting, threading all as directed, along with new GI fittings where ever replaced and required at site of site of size 15 mm borecomplete all as specified directed. 114 Supply & Fix as in replacement of GI tubing medium grade of size 50 mm bore with all fittings on wall/ trenches complete including cutting and thereading all as required at site complete all as specified directed.Note:Excavation & earthwork shall be measured & paid seperately 115 S&F in replacement Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of size 50mm complete all as specified and directed. 116 Supply & Fix as in replacement of GI tubing medium grade of size 40 mm bore with all fittings on wall/ trenches complete including cutting and thereading all as required at site complete all as specified directed.Note:Excavation & earthwork shall be measured & paid seperately 117 S&F in repair Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of size 40 mm complete all as specified and directed. 118 Supply & Fix as in replacement of GI tubing medium grade of size 25 mm bore with all fittings on wall/ trenches complete including cutting and thereading all as required at site complete all as specified directed. Note:Excavation & earthwork shall be measured & paid seperately 119 S&F in repair Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of size 25 mm complete all as specified and directed. 120 Supply & Fix as in replacement of GI tubing medium grade of size 20 mm bore with all fittings on wall/ trenches complete including cutting and thereading all as required at site complete all as specified directed. Note:Excavation & earthwork shall be measured & paid seperately 121 S&F in repair Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of size 20 mm complete all as specified and directed. 122 Supply & Fix as in replacement of GI tubing medium grade of size 15 mm bore with all fittings on wall/ trenches complete including cutting and thereading all as required at site complete all as specified directed. Note:Excavation & earthwork shall be measured & paid seperately 123 S&F in repair Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of size 15 mm complete all as specified and directed. 124 S & F in replacement Bib taps, cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe fixed of size 15 mmfor brass ferrule fancy type and fixed complete all as specified and directed. 125 Supply and fix Nipple suitable for HDPE water tankof size 40 mm complete all as specified and as directed. 126 Supply and fix in replacement PVC Ball valve ISI marked high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed of size 40mm complete all as specified and directed 127 Supply and fix PVC water tank 2000 Ltrs Capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I, complete all as directed incl disconnecting existing tank of any description and capacity complete. 128 Supply and fixingFramed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, hinges and handles etc. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 for valve pit chamber, raising main support and motor foundation supports etc.complete all specified and directed. 129 M & L for Over hauling and repair/replacement of unserviceable items ofPortable RO unit of capacity 80 LPD by disconnecting all pipe lines, filters catridges, RO Membrane , motor, float valveand water storage tank,all filter catridges(Pre Activated carbon ,Post Activated carbon, inline sedimant , pre particle filter), motor carbon brushes, pressure pump diaphram, float valve,solenoid valve,12/24v SMPS power supply unit , damaged piles lines , bends ,tee , elbow, water flow restrictor including cleaning of water storage tanks and testing (TDS ), fixing of pre filtersall respect and replacement of minor spare such as carbon brush ,tee ,elbow,pipe line,teflon tape,screws,nuts etc include in this quoted rate for smooth functioning of RO Plant complete all as specified and as directed.Note : Major spare parts shall be measured and paid seperately as supply only under relevant items of BOQ. 130 Supply only Reverse Osmosis membrane with clamps suitable for RO unit all as specified 131 Supply only Inline sediment filter with clamps suitable for RO unit all as specified 132 Supply only pre particle filter with food grade housing arrangement and with clamps suitable for RO unit all as specified 133 Supply only pre-activated carbon filter with clamps suitable for RO unit all as specified 134 Supply only Pressure pump 12/24vsuitable for RO unit all as specified 135 Supply only float switch suitable for RO unit all as specified 136 Supply only Post-activated carbon filter with clamps suitable for RO unit all as specified 137 Supply only RO pressure Pump Diaphram Head unitsuitable for RO unit all as specified 138 Supply only TDS,PH,Chlorine mesauring digital device all as specified 139 Supply only solenoid 12/24vsuitable for RO unit all as specified 140 Supply only 12/24v SMPS suitable for RO unit all as specified 141 Supply and fixing as in repair pre filter housingelementwithsuitable size of filter to protect RO includingPVC pipe of required length and all connected items complete all as specified and directed. 142 Supply, install, testing and commissioning ofChemical Dosing system havingtop dia 540mm x bottom dia 480mm x height 575 mm, net capacity 95 - 100 Ltr consisting of (i) water inlet line (ii) Dosing pump inlet arrangement (iii) Drain (iv) Overflow (v) Level Gauge (vi) inspection port (vii) Agitator 120 watt 800 - 900 RPM Single Phase flange mounted motor with plastic shaft and impeller (ix) provision of mounting Pump on Lid/wall along with dosing Injector of the following specification. Adjustble dosing pump max pressure 5kg/cm square& max flow rate 0 - 50 ltr / hr including all accessories such asLead tubing, Connecting Ferrules, check valves, non return valve all as directed. Power input 230V, 50 Hz, 40 SPM 1/30 fractional Horsepower, etc complete all as specified and directed. Make: - Model No. VST 1011 of Ravi Enterprise or equivalent as per E-in-Cs approved make.Note: Unit quoted rate shall be inclusive of taking down of old unserviceableplant and depositing same to MES store yard . 143 M&L for dewateringof Swimming Pool of size 50m x 25m (Olympic size pool ),Cleaning of Swimming pool bed,vertical walls complete with high pressure water jet to remove all masses, algae and dirt and removal of dirty waterwith sludge using non clog sludge machine and disposal of the same to a safe distance & applying of anti bacterial sterlization spray to walls, floors and applying muriatic acid, caustic soda or any other cleaning agent without damaging the existing tiles. Finally washing total surfaces with fresh water and make ready for fill up and ceilings all as directed.Note: (a) The Rate quoted by the contactor is deemed to include labours,tools and acessories andprovision of stickering of date of cleaning on the existing boardletter / figures White or Black colour and size as per existing font. (Date of Cleaned in format of (DD/MM/YY) Note : chemicals used for cleaning/PH level stablizer/anti Baterial/anti algae controller shall be supplied under relevant items 144 All as per Sl Item No. 143 here-in-before but Diving Pool of size 20 x 20 Meter complete all as specified and as directed. 145 All as per Sl Item No. 143 here-in-before but Balancing Tank of capacity 1,00,000 Gallon complete all as specified and as directed. 146 Supply only swimming pool grade Copper Sulphate crystal of superior qualityincluding stocking/ Handling and shifting complete all as specified and directed. 147 Supply only Swimming pool grade Hydro Chloric Acid (HCL) for regulating PH value of the pool complete all as specified and as directed. 148 Supplyonly swimming pool grade calcium based(Sodium Hypochloride) for water disinfectant as liquid form insealedcontainerhaving, chlorine concentration level not less than 12% and adding/mixing complete all as specified and as directed. 149 Supply only non ferrous Alum powder/crystal free from impurityclass Isuitable for swimming pools and adding/mixing as per direction of Engr-in-Charge to maintain water qualityincluding stocking/ Handling and shifting complete all as specified and directed. 150 Supply only Soda ash free from impurityclass Isuitable for swimming pools and adding/mixing as per direction of Engr-in-Charge to maintain water qualityincluding stocking/ Handling and shifting complete all as specified and directed. 151 Supply only Algae control gel/liquidfree from impurityclass Isuitable for swimming pools and adding/mixing as per direction of Engr-in-Charge to maintain water qualityincluding stocking/ Handling and shifting complete all as specified and directed. 152 Supply only chemically non reactive/lab quality Plastic mug 1 ltrs capacity complete all as specified and as directed. 153 Supply and fix in replacement ofchemically non reactive/Lab qualityPlastic bucket 35 ltrs capacity complete all as specified and as directed. 154 Supply and fix in replacement of nylon brush (soft quality) with wooden/HDPEbase of size 3 feet long, 2.5 (Inch) wide localy available best quality, suitable for fix with suction sweeper.complete all as specified and as directed. 155 Supply and fix in replacement ofnylon brushwithHDPEbase of size >18 Inch wide and handle > 20 feet long wide localy available best quality for cleaning walls of swimming pool complete all as specified and as directed. 156 Supply and fix in replacement offlexible pipe from suction sweeper pumps and Supply & fix PVC flexble hose pipe50mm OD including necessary jubilee clamps complete all as specified and as directed. 157 Supply and fix in replacement of nylon rope 25mm dia for suctionsweeper ( as per sample) complete all as specified and as directed. 158 Material and labour for opening the pressure filter vessel located in swimming pool of dia 2.8 Meter and height 2.6 meter for the following works:-(a)Opening the man hole cover and taking out entire filter media ie, existing stone aggregate , sand, quartz , slugde, algae etc(b)Cleaning of entire surfaces of sides , top and bottom of vessel by applying hydrochloric acidand thorough rinsing and make the vessel fit for re-filling the filter media.(c)Applying one coat of approved anti corrosive paint to entire internal surfaces of pressure filter including preparation of surfaces.(d) Re-fill the filter media with approved material of stone aggregate, river sand and white quartz in layers and properly packed upto existing level.All the material shall be rinsed thoroughly by using hydochloric solution and maintain the PH value at the range of 3 to 5.(e)Applying two coat of synthetic enamel paint to external surface of pressure filter vessel including preparation of surface etc and all as directed. 159 M&L for carrying out repair to trolley of suction sweeper pump set, including removing the pump and motor assembly carefully, dismantling rusted, bent or damaged MS frame members, cleaning entire surface, cutting and replacing corroded angle/channel sections with new mild steel of suitable size, welding, grinding and aligning to restore structural integrity. Work includes replacement of defective or jammed trolley wheels with new heavy-duty rubber/PU wheels of suitable load capacity, including fabrication of axle if required, welding, fitting and alignment. Entire metal frame surface shall be cleaned of rust and old paint using wire brush/scraper, then applied with one coat of red oxide primer and two coats of synthetic enamel paint of approved shade. Pump and motor set shall be re-mounted securely on trolley after repairs, reconnecting all mounting hardware as directed by Engineer-in-Charge, complete all as specified and directed. 160 M&L for carrying out repairs to 900mm wide suction sweeper head including dismantling the existing head assembly, cleaning and removing rust, replacing damaged or worn-out wheels with new nylon/plastic rollers of suitable size, fabricating and welding broken or bent brackets, repairing or replacing the metal body plate with mild steel sheet of suitable gauge, grinding sharp edges, tightening or replacing fasteners, restoring proper alignment of brush head and roller arms. Work includes thoroughly cleaning the base frame and applying one coat of red oxide primer and two coats of synthetic enamel paint for corrosion protection. The nylon bristle brush shall be checked for wear and refixed/replaced if found loose or damaged, ensuring smooth and uniform contact during sweeping operation. Complete all as specified and as directed by the Engineer-in-Charge 161 M&L for rewinding of 3-phase squirrel cage induction motor of capacity up to 3 HP, including removing the motor from its base, opening the end covers, dismantling the rotor, cleaning the stator core, removing burnt winding, preparing slots, rewinding the stator coils with super enamelled copper wire of same gauge and turns as per manufacturers specification, insulating with Class F insulation material, inserting wedges, varnishing with high-grade insulating varnish, oven drying, reassembling all components, aligning bearings, replacing terminal leads, testing for insulation resistance and load performance. Work includes cost of copper wire, insulating materials, varnish, labour, and testing equipment. Motor shall be tested under full load conditions for a minimum of 2 hours to ensure proper functioning. Complete all as specified and directed by the Engineer-in-Charge 162 M&L for carrying out repair to 3-phase DOL (Direct-On-Line) starter up to 5 HP capacity, including opening of enclosure, cleaning of all internal components, checking and tightening of loose terminals, replacing defective parts such as contactor coil, contacts, NO/NC auxiliary blocks, push buttons, overload relay, or indicator lamps with suitable rated spares as per original design, servicing of moving parts, reassembly, insulation testing, and functional testing under load conditions. The job includes cost of consumables like contact cleaner, terminal tags, and minor hardware. All replaced parts shall be measured and paid separately under relevant items. Complete all as specified and as directed by the Engineer-in-Charge 163 Taking down defective centrifugal/Monoblock pump set 10 HP to 15 HPby disconnecting the pump from motor after unscrewing nuts/ bolts of coupling, foundation, suction pipe delivery pipes and shifting of pump to workshop for repair/ servicing, comprising strip opening of pump, replacement of any defective parts, carrying out necessary lathe work, re-assembling and shifting from workshop to site, re-installation at location as directed by Engr-in-Charge, testing on full load capacity at least for 8 hrs, complete all as specified and as directed. Note :- (a)The spares shall be measured and paid seperately in the relevent items given below.(b) Cost of labour for replacement of spares and transportation are deemed to be incl in the quoted rate. (c)The pumpset shall be spared for one week for repair from the date of complaint given by AGE/ JE E/M regarding breakdown. Thecontactor is responsible for making alternate arrangement of pump set in case of time required more than one week.(d)In case services affected due to delay in repair of pump set, a penalty of Rs 500 per day will be levied from the contactor.(e)Please note that this penalty is exclusively other then the condition 67 of IAFW-2249 and shall be treated as interim condition of the contract.(f)The decision of the Accepting Officer in this regard shall be final and binding. 164 Supply only Ball bearing suitable for 10 HP to 15 HPmotor pump as per manufacturers design complete all as specified and as directed.Make : Tata/SKF/NBC 165 Supply only coupling bolt with nuts suitable for 10 HP to 15 HPmotor pump as per manufacturers design complete all as specified and as directed. 166 Supply only coupling Rubber Bush suitable for 10 HP to 15 HP motor pump as per manufacturers design complete all as specified and as directed. 167 Supply only split casing gaskets suitable for 10 HP to 15 HP motor pump as per manufacturers design complete all as specified and as directed. 168 Supply only Air cock grease nipple suitable for 10 HP to 15 HP motor pump as per manufacturers design complete all as specified and as directed. 169 Supply only shaft sleeves suitable for 10 HP to 15 HP motor pump as per manufacturers design complete all as specified and as directed. 170 Supply only water seal suitable for 10 HP to 15 HP motor pump as per manufacturers design complete all as specified and as directed. 171 Remetaling of shaft, turning, grinding as per the required size and polishing including provision of neck rings of impellers suitable for 10 HP to15 HP motor pump as per manufacturers design complete all as specified and as directed. 172 Supply only bronze impeller suitable for 10 HP to 15 HP motor pump as per manufacturers design complete all as specified and as directed. 173 M&Lfor suitable size of gland packing for 10 HPto 15 HP pump set as per manufacturers design complete all as specified and as directed. 174 Supply & fix in replacement adjustable CT/Direct operated thermal over load relay15 to 21 A for 10 HP to 15 HP motor3 phase 415v , 3 pole , with single phase protection including CTs complete all as specified and as directed. Make : L & T / Indo Asian /Schneider 175 M & L for servicing of starter by checking and servicing the contactor coil , over load relay coiland any other parts and replacement the burnt out wiring including any modification to pump starter panel by welding,cutting , grinding ,drillingtesting the panel complete all as specified and directedfor the10 HP to 15 HP capacity pump setsNotes :-(i) Minor spare parts such as nuts,bolts ,washers ,indicator lamps , start,stop push button and suitable size of copper wire are deemed to be included in quoted rate. 176 Supply & fix in replacement of3 Pole power contactor AC 415 V AC3 ( inductive load ) type 25 Amps with add on aux contact 2 NO + 2 NC50 Hz Model No. as per existing framesuitable for 10 HP to 15 HP Pump sets complete all as specified and as directed.Make : L & T / Indo Asian /Schneider 177 M&L for rewinding ofinduction electrical motor , 3 phase, 415 volts with suitable size of copper enameled winding wire and insulating materials incl disconnecting all electrical connections ,decoupling from pump,taking down the motor from foundation , cleaning and varnishing the stator & rotor winding, heating and drying, replacement of burnt terminals, greasing to bearings, re-assembling the motor and refixing of motor on the foundation by using new nut, bolts and washers, coupling with pump,checking alignment connecting all electrical connections,checking the vibrations, RPM and testing on full load complete all as specified and directed for 10 HP to 15 HPmotor capacity. 178 Taking down defective centrifugal /Monoblock pump set upto 5 HP by disconnecting the pump from motor after unscrewing nuts/ bolts of coupling, foundation, suction pipe delivery pipes and shifting of pump to workshop for repair/ servicing, comprising strip opening of pump, replacement of any defective parts, carrying out necessary lathe work, re-assembling and shifting from workshop to site, re-installation at location as directed by Engr-in-Charge, testing on full load capacity at least for 8 hrs, complete all as specified and as directed. Note :- (a)The spares shall be measured and paid seperately in the relevent items given below.(b) Cost of labour for replacement of spares and transportation are deemed to be incl in the quoted rate. (c)The pumpset shall be spared for one week for repair from the date of complaint given by AGE/ JE E/M regarding breakdown. Thecontactor is responsible for making alternate arrangement of pump set in case of time required more than one week.(d)In case services affected due to delay in repair of pump set, a penalty of Rs 500 per day will be levied from the contactor.(e)Please note that this penalty is exclusively other then the condition 67 of IAFW-2249 and shall be treated as interim condition of the contract.(f)The decision of the Accepting Officer in this regard shall be final and binding. 179 Supply only coupling bolt with nuts suitable for upto 5 HPmotor pump as per manufacturers design complete all as specified and as directed. 180 Supply only Ball bearing suitable for upto 5 HP motor pump as per manufacturers design complete all as specified and as directed.Make : Tata/SKF/NBC 181 Supply only split casing gaskets suitable for upto 5 HPmotor pump as per manufacturers design complete all as specified and as directed. 182 Supply only coupling Rubber Bush suitable for upto 5 HPmotor pump as per manufacturers design complete all as specified and as directed. 183 Supply only Air cock grease nipple suitable for upto 5 HPmotor pump as per manufacturers design complete all as specified and as directed. 184 Supply only shaft sleeves suitable for upto 5 HPmotor pump as per manufacturers design complete all as specified and as directed. 185 Supply only water seal suitable for upto 5 HPmotor pump as per manufacturers design complete all as specified and as directed. 186 Remetaling of shaft, turning, grinding as per the required size and polishing including provision of neck rings of impellers suitable for upto 5 HP motor pump as per manufacturers design complete all as specified and as directed. 187 Supply only bronze impeller suitable for upto 5 HPmotor pump as per manufacturers design complete all as specified and as directed. 188 Supply and fix as in repair 4 Pole MCCB ,415 volts,fixed type ,125 Amp, 50 Hz, with rupturing capacity 25 KA in theexisting pump starter panel including connecting up incoming/out going cables with suitable lugs and testing complete all as specified and as directed. Make: Indoasian/L&T/ Legrand 189 M&L for rewinding ofelectrical motor , 3 phase, 415 volts with suitable size of copper enameled winding wire and insulating materials incl disconnecting all electrical connections ,decoupling from pump,taking down the motor from foundation /base, cleaning and varnishing the stator & rotor winding, heating and drying, replacement of burnt terminals, greasing to bearings, re-assembling the motor and refixing of motor on the foundation/ base of sunction sweeperby using new nut, bolts and washers, coupling with pump,checking alignment connecting all electrical connections,checking the vibrations, RPM and testing on full load complete all as specified and directed upto 5 HPmotor capacity. 190 M & L for servicing of starter by checking and servicing the contactor coil , over load relay coiland any other parts and replacement the burnt out wiring including any modification to pump starter panel by welding,cutting , grinding ,drillingtesting the panel complete all as specified and directedfor theupto 5 HPcapacity pump setsNotes :-(i) Minor spare parts such as nuts,bolts ,washers ,indicator lamps , start,stop push button and suitable size of copper wire are deemed to be included in quoted rate. 191 Supply and fix in replacement single phase 240V50HzDOL starter with OLR relay suitable for upto 4 HP monoblock pump sets inculding proper termination,testing and all connected acessories all as are specified and directed. 192 Cleaning of service tanks of the capacity as mentioned below on roof top of bldgs upto three storey after disconnection from inlet and outlet pipe, removing of float valve of service tank and keep aside safely for reuse drain out water through drain plug, cleaning thoroughly to remove all scales and dirt by brushing internal surface, cleaning properlyinside with soda wash, flushing out with fresh water, re-positioning of tank at same place, re-connecting inlet and outlet pipes, closing of drain plug, re-installation of float valve duly cleaned, writing/ labelling the record of cleaning carried out with white bold letter such asTANK CLEANED ON--------- (month and year), including removing creepers, vegitation and roots of plants, trees branches on or surrounding of service tank complete all as directed.Note:-(i) Unit rate quoted is deemed to be included for testing of water supply in tank both inlet and outlet flow during next supply hours early in the morning or late in evening.(ii) Contractor shall maintain a pucca bound register for cleaning carried out with date and obtain users signature and remarks if any and this register to be submitted alongwith RAR.(iii)Contractor is liable to rectify any damages to the external finishes of the bldg occured during the cleaning process, i.e. scrubbing and touch up with external paints as existing specifications. Unit rate quoted is deemed too be included the cost of the same.(iv)All sort of petty T&P items such as ladder, safety equipment, nuts, bolts, washers etc. required to accomplish the job shall be provided by the contractor with out any extra cost to dept. 193 (a)For RCC /PVC tank exceeding 200 litters and not exceeding 500 ltrs 194 (b)For RCC /PVC tank exceeding 501 litters and not exceeding 1000 ltrs 195 (c)For RCC /PVC tank exceeding 1001 litters and not exceeding 2000 ltrs 196 (d)For RCC /PVC tank exceeding 2001 litters and not exceeding 5000 ltrs 197 (e)For RCC /PVC tank exceeding 5001 litters and not exceeding 25000 ltrs 198 Material and labour for preparation of old painted external surface by brooming down scrubbing with steel wire brush, scraping old distempered and painted surface and applying two coat of cement base paint to service tanks in building and under ground sump/ RCC Tanks all specified for tanks capacity of 200 to 500 Ltrs. 199 Material and labour for preparation of old painted external surface by brooming down scrubbing with steel wire brush, scraping old distempered and painted surface and applying two coat of cement base paint to service tanks in building and under ground sump/ RCC Tanks all specified for tanks capacity 501-1000 Ltrs. 200 Material and labour for preparation of old painted external surface by brooming down scrubbing with steel wire brush, scraping old distempered and painted surface and applying two coat of cement base paint to service tanks in building and under ground sump/ RCC Tanks all specified for tanks capacity 1001-2000 Ltrs. 201 Material and labour for preparation of old painted external surface by brooming down scrubbing with steel wire brush, scraping old distempered and painted surface and applying two coat of cement base paint to service tanks in building and under ground sump/ RCC Tanks all specified for tanks capacity 2001-5000 Ltrs. 202 Taking down and relaying of existingDI water pipe lines of size 150 mm bore but of any type includings all fittings after removal of scaling, cleaning and flushing etc complete all as specified and directed.Note:Excavation & earthwork shall be measured & paid seperately 203 Taking down and relaying of existingDI water pipe lines of size 100/80 mm bore but of any type includings all fittings after removal of scaling, cleaning and flushing etc complete all as specified and directed.Note:Excavation & earthwork shall be measured & paid seperately 204 M&L as in replacement for Ductile Iron Pipe (DI Pipes), ISI marked, Class K-7, 150 mm dia laid in trenches including jointing material such as EPDM Rubber Gasket and suitable type of grease etc complete all as specified and directed.Note :- (i)DI fitting/special shall be measured and paid separately.(ii)Excavation & earthwork shall be measured & paid seperately 205 Supply and fixing in replacement Non return valve (confirming to IS-5312) (NRV) of size 150 mm ISI marked, CI body suitable for 150 mm dia pipe line complete all specified and directed 206 S&F in replacementfoot valve (confirming to IS-4038) cast iron of size 150 mm bore including rubber insertion, packing material, nuts, bolts, and washer with suitable new one all as specified and directed. 207 Supply and fixing in replacement Sluice valve of size 150 mm dia Cl body, both ends flanged duly drilled, ISI marked with IS-14846-2000, PN-1.6 having Stainless Steel spindle and check nut including operating wheel, fixing with new nuts, bolts, washers and rubber insertion/packing complete all specified and directed. 208 Material and Labour for dismantling the brassspindle from 150 mm dia bore sluice valves in various locations and reconditioning the sluice valve by replacing SS/bronze spindle, spindle nuts with brass ring, gland nuts complete all as specified and as directed. 209 Material and Labour for gland packing in leaking Sluice Valves of 150 mm dia size Complete including replacing/tightening the existing bolts and nuts etc. complete all as directed . 210 Material and Labour for Cutting DI pipes in position for insertion of new tees and socket of size 150 mm dia Complete all as specified and as directed. 211 Supply and fixing in replacement butterfly valve(confirming to IS-13095) of size 150 mm dia Cl body, ISI marked with IS-13095 having double door convex shape to prevent eddies and reaches head loss, neoprene rubber sealing and fitted complete all specified and directed 212 Cutting the existing broken / cracked CI/DI/GI/Asbestos Cement Pipe line of size upto 150mm dia, by dewatering the lekage water from site and removing the old pipe line and addition / alteration to pipe by providing new pipe,welding,bending,grinding,including all accessories such as tee,elbow,collar etc , and ensure any leakage with pressure test complete all as specified and as directed.Note : Pipes and mechanical collar shall be measured and paid seperately 213 M&L for specials fittings suitable for Cast iron / ductile iron /Asbestos cement pipe made out of MS Plate of 12 mm thick complete with mechanical/detachable type arrangement as per site requirementwith MS bolts and nuts of suitable size and MS sheet fabricated to required dia of pipe for prepration of collar/flange, on any pipe leak or cracks of pipe for arresting the leakage complete including rubber ring, packing rubber sheet,set of two collar rings of size 150 mm borecomplete all as specified and as directed. 214 M&L as in replacement for Ductile Iron Pipe (DI Pipes), ISI marked, Class K-7, 100 mm dia laid in trenches including jointing material such as EPDM Rubber Gasket and suitable type of grease etc complete all as specified and directed.Note :- (i)DI fitting/special shall be measured and paid separately. (ii)Excavation & earthwork shall be measured & paid seperately 215 Supply and fixing in replacement Non return valve (confirming to IS-5312) (NRV) of size 100 mm ISI marked, CI body suitable for 100 mm dia pipe line complete all specified and directed 216 S&F in replacementfoot valve (confirming to IS-4038) cast iron of size 100 mm bore including rubber insertion, packing material, nuts, bolts, and washer with suitable new one all as specified and directed. 217 Supply and fixing in replacement Sluice valve of size 100 mm dia Cl body, both ends flanged duly drilled, ISI marked with IS-14846-2000, PN-1.6 having Stainless Steel spindle and check nut including operating wheel, fixing with new nuts, bolts, washers and rubber insertion/packing complete all specified and directed. 218 Material and Labour for dismantling the brass spindle from 100 mm dia bore sluice valves in various locations and reconditioning the sluice valve by replacing SS/bronze spindle, spindle nuts with brass ring, gland nuts complete all as specified and as directed. 219 Supply and fix replacement ofleather packing suitable for foot valve 80 to 100 mm dia, suction pipe flanged connected to pumpsets including replacement ofnuts and bolts etc all as specified and directed 220 Material and Labour for gland packing in leaking Sluice Valves of 100 mm dia size Complete including replacing/tightening the existing bolts and nuts etc. complete all as directed . 221 Material & Labour as in repair for Construction ofValve pit having inner dimensions 900 mm x 900 mm x 900 mm with foundation PCC 1:4:8 type D2 using 40mm grade stone aggregate, brick work with sub class B old size built in Cement mortar 1:6, PCC 1:2:4 type B1 using 20mm stone aggregate for Coping, 15 mm thick rendering plaster in CM 1:4 inluding MS cover with locking arrangement all as specified and as directed.Note :- MS work as in Chamber Covers shall be measured and paid separately under relevant item of this schedule. 222 Material and labour for Fabricate supply and fix valve chamber coversmade out of suitable size MS angle/MS plate/flat/rod, hinges, locking arrangement including painting with two coats of synthetic enamel paint over one coat of red oxide primer including removimg existing unserviceable rusted cover all as directed. 223 Material and labourfor Painting with two coats of synthetic enamel paint over a coat of zinc chrome on surfaces of any description, over 10cm in width or girth,not otherwise described complete all specified and directed. 224 Material and labourCleaning of valve pit chamber for sluice/gate valve of 50/80/100/150/200/ size by removing mud/ grass/ sludge/ other waste materialsfrom the chamber and from surroundings upto 1mtr distance, carryout petty cement repairs with cement mortar 1:4, apply one coat of white wash on cemented surfaces and one coat of synthetic paint on steel surfaces complete to make an operator friendly valve chamber complete as specified and directedNote :- Periodicity and locations of valve chambers shall be given as per requirement by the Engineer-in-Charge. 225 Cutting the existing broken / cracked CI/DI/GI/Asbestos Cement Pipe line of size upto 100mm dia, by dewatering the leakage water from site and removing the old pipe line and addition / alteration to pipe by providing new pipe,welding,bending,grinding,including all accessories such as tee,elbow,collar etc , and ensure any leakage with pressure test complete all as specified and as directed.Note : Pipes and mechanical collar shall be measured and paid seperately 226 M&L for specials fittings suitable for Cast iron / ductile iron /Asbestos cement pipe made out of MS Plate of 12 mm thick complete with mechanical/detachable type arrangement as per site requirementwith MS bolts and nuts of suitable size and MS sheet fabricated to required dia of pipe for prepration of collar/flange, on any pipe leak or cracks of pipe for arresting the leakage complete including rubber ring, packing rubber sheet,set of two collar rings of size 100 mm borecomplete all as specified and as directed. 227 Supply and Fixing as in replacement MCCB, 4 poles 415 Volts, 100 Amps, 16 KA, 50 Hz, AC, adjustable thermal and magnetictype in the existing pump starter panel including connecting up incoming/out going cable with suitable lugs and testing complete all as specified and as directed.Make : Legrand/Indo asian/L&T 228 M&L as in replacement for Ductile Iron Pipe (DI Pipes), ISI marked, Class K-7, 80 mm dia laid in trenches including jointing material such as EPDM Rubber Gasket and suitable type of grease etc complete all as specified and directed.Note :- (ii) DI fitting/special shall be measured and paid separately. (i)Excavation & earthwork shall be measured & paid seperately 229 M & L for DI specials and fittings as per IS for spigot and socketed pipes or flanged pipe for water mains branch lines such as bends(any type radious and angle ) tapers any type (straight, bend,increasing,decresing,or double socket etc) tee pices,single branch,Y juntion, double branch, cross, including connecting pieces one end flanged and other socket or spigot and bell mouth pices suitable for rubber joint,tyton joint up to 150 mm bore and conforming to IS-9523: 2000 complete all as specified and directed. 230 Note :-(a) In case of laying of CI/GI/DI pipe line is to be executed in civil area, it will be the responsibility of the contractor to obtain necessary permission for cutting of road & berm from BWSSB. 231 (b) For this purpose amount to be paid online to BWSSB, same is deemed to be included in unit quoted rate. 232 (c) The T&P like JCB, Drill Machine, Moveable Generator etc required for cutting of road shall be arranged by the contractor & no extra cost shall be paid for the same. 233 (d) After execution of work, the contractor will make good disturbed portion of road with bitumen or PCC complete as directed by Engineer-in-Charge. Cost of the same is deemed to be included in unit quoted rate. 234 Supply and fixing in replacement Sluice valve of size 80mm dia Cl body, both ends flanged duly drilled, ISI marked with IS-14846-2000, PN-1.6 having Stainless Steel spindle and check nut including operating wheel, fixing with new nuts, bolts, washers and rubber insertion/packing complete all specified and directed. 235 Material and Labour for dismantling the brass spindle from 80 mm dia bore sluice valves in various locations and reconditioning the sluice valve by replacing SS/bronze, spindle nuts with brass ring, gland nuts complete all as specified and as directed. 236 Material and Labour for gland packing in leaking Sluice Valves of 80 mm dia size Complete including replacing/tightening the existing bolts and nuts etc. complete all as directed . 237 S&F in replacementfoot valve (confirming to IS-4038) cast iron of size 80 mm bore including rubber insertion, packing material, nuts, bolts, and washer with suitable new one all as specified and directed. 238 Supply and fixing in replacement Non return valve (confirming to IS-5312) (NRV) of size 80 mm ISI marked, CI body suitable for 80 mm dia pipe line complete all specified and directed 239 Supply and fixing in replacement Non return valve (confirming to IS-5312) (NRV) of size 65 mm ISI marked, CI body suitable for 65 mm dia pipe line complete all specified and directed 240 Material and Labour for Cutting DI pipes of size 200/150/100/80 in position for insertion of new tees and socket of size15/20 mm dia Complete all as specified and as directed. 241 Material and Labour for Plain Cement Concrete (1:2:4), type B1 (using 20 mm graded crushed stone aggregate) as in Coping, bands benching etc including finishing the concrete surfaces even and smooth without using extra cement including necessary form work Complete all as specified and directed. 242 Supply and fixing in replacement of Air Release Valve of size 40 mm dia Cl body, ISI marked of IS 14845 of 1.6 PNincluding fixing arrangement of existing 150 mm dia DI pipe line with new nuts, bolts, washers and rubber insertion/packing complete all specified and directed. 243 Making arrangement to flush out the existing pipe line of any type upto 50mm bore and upto 100m length, applying 4.5 N/sqmm pressure to remove scalings/ sludges/ other blocking materials to make smooth flow of water including testing all as specified and directed. 244 Making arrangement to flush out the existing pipe line of any type 63 to 100 mm bore and upto 100m length, applying 4.5 N/sqmm pressure kg/sq cm pressure to remove scalings/ sludges/ other blocking materials to make smooth flow of water including testing all as specified and directed. 245 Material and labour for Making arrangement to flush out the existing pipe line of any type 110 to 150mm bore and upto 100m length, applying 4.5 N/sqmm pressure to remove scalings/ sludges/ other blocking materials to make smooth flow of water including testing all as specified and directed. 246 Material and labour for Making arrangement to flush out the existing pipe line of any type 160 to 200 mm bore and upto 100m length, applying 4.5 N/sqmm pressure to remove scalings/ sludges/ other blocking materials to make smooth flow of water including testing all as specified and directed. 247 Note for item 243 to 246 :-(i)The Contractor is deemed toarrange necessary tools and equipments, removing or alteration of fittings from existing pipe lines, arragement of plugging devices, etc to build up specified pressure required to wash out the pipes. This will be inclusive in quoted rate. (ii)Excavation and earth work required shall be measured and paid seperately. (iii)The flushing out shall be carried out with fresh filled water of well only duly chlorinated with specified sodium hypochlorite solution to disinfect the pipe lines from all pathogens and Coliform organisms.This will be inclusive in quoted rate. 248 Material and labour for dewatering & Cleaning ofRCC Over Head Tanks of the followingcapacities by comprisingof the followings 09 (NINE) stage of cleaning process complete all as specified and directed:-(i)De-watering by high pressure submersible pump all complete (Notes for item No 249 to 261) :- The Bidder shall take into consideration for following points while quoting his rate for this item andthe unit rate is deemed to be included for :-(i) The contractor shall provide dewatering pump of suitable capacity and mobile generatorfor operation of dewatering by high pressure submersible pump (or) Diesel driven high pressure pump and the rate quoted is inclusive of rent/hiring charges complete. (ii) Cuttingand filling, cleared of shrubs, vegetation, grass bush, weed, trees and sapling not exceeding 30 cm in girth, measured at a height of two metre above ground level. Useful material shall be stacked.(iii) Material removed from the tank shall be disposed off to out side MD land.(iv) Tank shall be made available for cleaning for a period of 8 hours only and contractor has to arrange sufficient labour/ T&P to complete the job with the given period only. or otherwise penalty shall be imposed @ Rs 500/- per day.(v) All safety gadgets like safety Belts, special safety ladder, Helmets, Heavy Duty Gum Boots,Gloves, Safety Goggles, Masks, Aprons, etc. for complete security safe operations, Storage and Cleaning equipment’s like Scrubbers/Wipers, Storage drums, Sludge Collectors and Cisterns, etc. must be integral part of system. (vi) Removal of sludge fromRCC Over Head Tanks(vii)Cleaning of walls, floors, ceiling etc by high pressure jet pump 80-180 bar pressure all complete(viii)Removing dirt and sludge by vacuum pump(ix) Anti- Bacterial Treatment of inside of tank effective againstall pathogens all complete.(x) Sterilization of the tank atomosphere by UV radiation inside of the tank.(xi) Applying one coat of white wash to internal surfaces.(xii)Replace nylon net for vent pipes &man hole cover(xiii)Writing letter in bold with white paint on black colour back ground such as sump number, capacity, cleaned on Date & Due on Date etc 249 250000 gallon capacity22 Mt heightat ETI Tank 250 150000 gallon capacity22 Mt heightat Bhatiya tank 251 150000 gallon capacity15 Mtr height at GLR 1 and GLR 2 Double tank 252 150000 gallon capacity12.5 Mtr height at IMH Area 253 150000 gallon capacity22 Mt height at E&ITI Tank 254 100000 gallon capacity 18 Mtr height at Bhatia tank,West 255 75000 gallon capacity 18 Mtr height at Umbrella tank 256 50000 gallon capacity18 Mtr height at Domestic Area 257 30000 gallon capacity25 Mtr height at CE Complex 258 25000 gallon capacity16 Mtr height at MAP, 54 Civ. 259 25000 gallon capacity18 Mtr height at Double tank168 WO 260 20000 gallon capacity12 Mtr height at Height at KV School 261 20000 gallon capacity12 Mtrheight at 90 CIV Pump House 262 M & L for Fixing in repairs Water Level Indicator consisting of float ball, nylon rope, Scale for water level indication made out of MS frame with pulley and indicating pointer for OHT at different places all as specified and directed . 263 Supply and fixing as in repair for aluminium earth continuity conductor or main earthing lead fixed to wall /roof top for lightning arresterfixed to OHT or other indicated situation for loop earthing etc. as required for 25 mm x 3 mm thick, aluminium using porcelain clit/post insulators with screw / selfdril GIscrew with rubber washer , complete all as specified and directed. 264 Supply and fix as in repair TPN MCB ,415 volts,fixed type ,40 Amp, 50 Hz, with rupturing capacity 10 KA in theexisting pump starter panel including connecting up incoming/out going cables with suitable lugs and testing complete all as specified and as directed. Make: Indoasian/L&T/ Legrand 265 S&F as in repair single core multistrand flexible copper cable of size 35 Sqmm x 1 core , includinglugs , connecting up with nuts and bolts, insulation tape wrappingetc , the selection of cable as per colour code all as specified and directed Make : Havells /Polycab/RPGAsian 266 Excavation in trenches not exceeding 1.5 mtr in width and not exceeding 1.5 mtr in depth for laying of cables up to proper level and laying of pipelines etcinany type of soil, complete all as specified and directed. 267 Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick, complete all as specified and directed. 268 Removing surplus excavated material (soil) not exc 50 meter and depositing where directed at a level not exc 1.5 meter above the starting point, complete all as specified and directed. 269 Material and labour for Spreading ribbed soil in trenches as in cable cushioning all as per IS 1255-1983, complete all as specified and directed.Note :- (i)Excavated approved soil shall be ribbed by using sieve to separate composite particles etc. as per IS and refilling in trenches before laying of cable 8 CM and 15 CM after laying of cable. This is then gently punned down to a depth of 10 cm above the top of upper most cable (ii) For the purpose of measurement only punned thickness shall be considered for payment. 270 Material and labour for well burnt bricks ‘B’ class as mechanicalprotection to under ground cables laying with length of the bricks equal to the width of the trench, complete all as specified and directed. 271 Material and labour for Cutting existing road/PCC/Drain for laying of GI or any type of pipe including necessary earthwork, excavation exc 600mm depth but not exc 1mtr depth, 800 mm wide including making good existing surface with 150 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate, complete all as specified and directed. Note :-The tenderer shall take into consideration for following points while quoting rate for this item andthe unit rate is deemed to be inclusive for :-(i) Earth work and excavation in any type of soil(ii) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick complete all as specified and as directed.(iii) Removing excavated material to out side MD.(iv)Laying of any type/any bore of pipe in trenches including taking down. Supply of pipe shall be measured and paid separately(v)150 mm thickPCC 1:2:4 type B1 using 20mm graded stone aggregate as inroad to make good existing disturbed surfaces. 272 Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 100 mm dia suitable for 0.4 mpa working pressure. 273 Material and labour in repair for 3 ½ core 70 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make:- Havells/ Polycab/ RPG Asian Note - Earthwork and bricks to be paid separately in respective items. 274 Material and labour in repair for 3 ½ core 50 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make:- Havells/ Polycab/ RPG Asian Note - Earthwork and bricks to be paid separately in respective items. 275 Supply, installation, commissioning and testing of factory assembled, floor mounted, free standing type tested LT Feeder pillar panel, with canopy, as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS compliants & Halogen free. The manufacturer of boards/panels shall submit a copy oftype test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be minimum 200mm for air circulation & to minimize temp rise. Panel should be fitted with one No.polycarbonate IP 65, 9 W LED translucent bulk head luminaire color lamp not less than 6500K, PF >0.95 under canopy for easy maintenance. Panel shall be fitted outside with one No of 16 Amp 3 Pole IP65 industrial socket and 01 No. of 32Amp 5P IP 65 industrial socket. 3 Phase and neutral 630 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20mm graded aggregate forbedding upto a height of 45 CM above ground level, including dismanting and taking out old U/s LT panel board and reconnecting existing LT UG Cable with new panel board amplete all as specified and all as directed and comprising of the following:- 276 (a) ON load change over switch 4 Pole, 415 V of capacity 400 Amp, 36 KA - 01 No. (b) MCCB with thermal magnetic release 4 Pole, 415 V of capacity400 Amp,36 KA- 02 Nos.(c) Multifunction Meter (V,I,PF) with suitable capacity of CTs- 01 No(d) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set. (e) Space for spare feeder - 01 No. Note :-(i) The Contractor shall submit the drawing for approval of GE before executing the work.(ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S.(vi) MCCB should be ICu =100% ICs.(v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS). 277 Supply, installation, commissioning and testing of factory assembled, floor mounted, free standing type tested LT Feeder pillar panel, with canopy, as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS compliants & Halogen free. The manufacturer of boards/panels shall submit a copy oftype test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be minimum 200mm for air circulation & to minimize temp rise. Panel should be fitted with one No.polycarbonate IP 65, 9 W LED translucent bulk head luminaire colour lamp not less than 6500K, PF >0.95 under canopy for easy maintenance. Panel shall be fitted outside with one No of 16 Amp 3 Pole IP65 industrial socket and 01 No. of 3 2Amp 5P IP 65 industrial socket. 3 Phase and neutral 400 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20mm graded aggregate forbedding upto a height of 45 CM above ground level, including dismanting and taking out old unserviceable LT panel board and reconnecting existing LT UG Cable with new panel board complete all as specified and all as directed. This comprising of the following:- 278 (a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 200 Amp, 25 KA - 01 No (Incomer). (b) MCCB with thermal magnetic release 4 Pole, 415 V of capacity63 Amp,10 KA- 05 Nos (OG).(c) Multifunction Meter (V,I,PF) with suitable capacity of CTs- 01 No(d) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set. (e) Space for spare feeder - 01 No. Note :-(i) The Contractor shall submit the drawing for approval of GE before executing the work.(ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S.(vi) MCCB should be ICu =100% ICs.(v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS). 279 Supply, installation, testing & commissioning of maintenance free chemicalearthing system comprising of 17mm dia copper bondedrod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducingliquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 A by any NABL accredited lab. The above mentioned rod shall be installed in 4-6 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation including taking down existing one, complete all as specified and directed..Make : Model HTSP 317 of safeTrode or equivalent in Snaga/ Cubes 6 Global 280 The quoted rate shall also deemed to be included the following :- (i)Prior toinstallation of maintenance free chemicalearthing, soil resistivity test to be carried out at the location where earthingwork to be donein presence of Engr-in- Charge/JE (E/M),user and the report has tosubmitto Garrison Engineer with recommendation of manufacturer, if required additional interconnection ofearthing (not more than 08 number of earthing) to achive earth result less then 1 Ohms. The arrangement done for soil resistivity testingandsubmission of report with recommendationdeemed to be included in the quoted rate. 281 (ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors. 282 (iii) Rateofearth energizer compound of 25 Kg of 02 bags and earthresistance reducingliquid 10 litre per cane for each pit deemed to be included in the quoted rate. 283 (iv)Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor along with the sample approval 284 (v) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH value should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete. 285 (vi) Copper strip of size 20 x 3 mm shallbe fixed on proper post insulator at the instrument end (copper strip upto 7.5 RM shall be considered in unit quoted rate and extra will be measured and paid separately). 286 (vii)Testing of earth shall be carriedout in presence ofdepartmental and user representativeand report shall be submitted to Garrison Engineer duly signed by all concerned. 287 (viii)Earth resistance tester will be provided by the contractor.Tester should be calibrated from authorised company/ lab. 288 (ix)Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintained duly signed by all concerned.After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained. 289 (x) The contractor shall give a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion. 290 (xi) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including soft/ disintegrated or hard rock. 291 (xii) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is maintained. 292 (xiii) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing for each earthing shall be retained from payment due to the contractor from final bill for the guarantee period. 293 (xiv) The electrode shallcarry manufacturers name . 294 (xv) The connection clamp shall be permanentlly welded to the copper boundedrodto avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination. 295 (xvi) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm. 296 (xvii)Earth work such as auguring andmaking good the surrounding area shall carried out in any type of soil. 297 (xviii)The contractor shall submit CPRI India certified document for copper bounded rod to ensure genuineness of material. 298 (xix) Sign boardof mild steel sheet 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxideZinc chrome primer showing result of earthing shall be fixed near the earth pit after completion as directed by engr -in- charge. 299 Material and labour for Earth pit cover madeof heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 7.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mm for each electrode pit complete including taking down old unserviceable pit cover of any decription all as specified and directed.Make : Model SEPC 250 of SAFE TRODE or equivalent in Snaga/ Cubes 6 Global 300 S&F in repair copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc including taking down existing old unserviceable copper strip etc, complete all as specified anddirected. Note : - All Joints should be joined by Exothermic Welding or Brazing. 301 Supply and fix for GI pipe light grade 50 mm dia for cable protection on road crossings /plinth protection with fixed to the pole wall etc along withsuitable fittings for cable protection etc complete all as specified and directed. 302 Material and labour in repair for3 ½ core 25 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make:- Havells/ Polycab/ RPG Asian Note - Earthwork and bricks to be paid separately in respective items. 303 Material and labour in repair for 4 core 10 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make:- Havells/ Polycab/ RPG Asian Note - Earthwork and bricks to be paid separately in respective items. 304 Supply, installation, commissioning and testing of factory assembled, floor mounted, free standing type tested LT Feeder pillar panel, with canopy, as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS compliants & Halogen free. The manufacturer of boards/panels shall submit a copy oftype test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be minimum 200mm for air circulation & to minimize temp rise. Panel should be fitted with one No.polycarbonate IP 65, 9 W LED translucent bulk head luminaire color lamp not less than 6500K, PF >0.95 under canopy for easy maintenance. Panel shall be fitted outside with one No of 16 Amp 3 Pole IP65 industrial socket and 01 No. of 32Amp 5P IP 65 industrial socket. 3 Phase and neutral 400 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20mm graded aggregate forbedding upto a height of 45 CM above ground level, including dismanting and taking out old U/s LT panel board and reconnecting existing LT UG Cable with new panel board amplete all as specified and all as directed and comprising of the following:- 305 (a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 250 Amps, 25 KA- 01 No (Incomer).(b) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 160Amps, 25 KA- 01 Nos.(c) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 63Amps, 10 KA- 01 Nos.(d) Multifunction Meter (V,I,PF) with suitable capacity of CTs- 01 No.(e) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set.(f) Space for spare feeder - 01 No. Note :-(i) The Contractor shall submit the drawing for approval of GE before executing the work.(ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S.(vi) MCCB should be ICu =100% ICs.(v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS). 306 Supply, installation, commissioning and testing of factory assembled, floor mounted, free standing type tested LT Feeder pillar panel, with canopy, as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS compliants & Halogen free. The manufacturer of boards/panels shall submit a copy oftype test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be minimum 200mm for air circulation & to minimize temp rise. Panel should be fitted with one No.polycarbonate IP 65, 9 W LED translucent bulk head luminaire color lamp not less than 6500K, PF >0.95 under canopy for easy maintenance. Panel shall be fitted outside with one No of 16 Amp 3 Pole IP65 industrial socket and 01 No. of 32Amp 5P IP 65 industrial socket. 3 Phase and neutral 600 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20mm graded aggregate forbedding upto a height of 45 CM above ground level, including dismanting and taking out old U/s LT panel board and reconnecting existing LT UG Cable with new panel board amplete all as specified and all as directed and comprising of the following:- 307 (a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 400 Amps, 36 KA- 01 No (Incomer).(b) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 200Amps, 25 KA- 01 No.(b) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 160Amps, 25 KA- 03 Nos.(b) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 63 Amps, 10 KA- 02 No(c) Multifunction Meter (V,I,PF) with suitable capacity of CTs- 01 No.(d) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set.(e) Space for spare feeder - 01 No. Note :-(i) The Contractor shall submit the drawing for approval of GE before executing the work.(ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S.(vi) MCCB should be ICu =100% ICs.(v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS). 308 Material and labour for dewatering & Cleaning of RCC UG sumps of the followingcapacities by comprisingof the followings 09 (Nine) stage of cleaning process complete all as specified and directed(i)De-watering by high pressure submersible pump complete (Note for item No 309 to 316 :-The Bidder shall take into consideration for following points while quoting his rate for these items andthe unit rate is deemed to be included for :-(i) The contractor shall provide dewatering pump of suitable capacity and mobile generatorfor operation of dewatering by high pressure submersible pump (or) Diesel driven high pressure pump and the rate quoted is inclusive of rent/hiring charges complete. (ii) Cuttingand filling cleared of shrubs, vegetation, grass bush, weed, trees and sapling not exceeding 30 cm in girth, measured at a height of two metre above ground level. Useful material shall be stacked.(iii) Material removed from the tank shall be disposed off out side MD land.(iv) Tank shall be made available for cleaning for a period of 8 hours only and contractor has to arrange sufficient labour/ T&P to complete the job with the given period only. or otherwise penality shall be imposed @ Rs 500/- per day.(v) Removal of sludge from sump(vi)Cleaning of walls, floors, ceiling etc by high pressure jet pump 80-180 bar pressure all complete(vii)Removing dirt and sludge by vaccum pump(viii) Anti- Bacterial Treatment of inside of tank is effective againstall pathogens all complete.(ix) Sterilization of the tank atomosphere by UV radiation inside of the tank.(x) Applying one coat of white wash internal surfaces.(xi)Replace nylon net for vent pipes &man hole cover(xii)Writing letter in bold with white paint on black colour back ground such as sump number, capacity, cleaned on Date & Due on Date etc 309 Underground sump of capacity 200000 gallon at Range pump house. 310 Semi underground sump of capacity 200000 gallon at Ayyappa Temple/ pump house. 311 Semi underground sump of capacity 120000 gallon at Service tank Pump house 312 Underground sump of capacity 50000 gallon at Gurukul 313 Semi underground sump capacity of 50000 at AFTC Pump House 314 Underground sump of capacity50000 gallon at AFTC Pump House, range pump house 315 Underground sump of capacity 20000 gallon at 91 CIV Pump house 316 Underground sump of capacity 10000 gallon at CE Complex/ pump house 317 M & L for Fixing in repairs Water Level Indicator consisting of float ball, nylon rope, Scale for water level indication made out of MS frame with pulley and indicating pointer for UG sumpat different places all as specified and directed . 318 Cleaning of UGopen static Water Tank (SWT) of the followingcapacities by comprisingof the followings 07 (Seven) stage of cleaning process for the undermentioned capcities complete all as specified and directed:-(i)De-watering by high pressure submersible pump all complete (ii) Removal of sludge/mud/silt/sand from sump and disposal out side MD land(iii)Cleaning of walls, floors, ceiling etc by high pressure jet pump 80-180 bar pressure all complete(iv)Removing dirt and sludge by vacuum pump(v) Applying one coat of white wash internal surfaces.(vi)Replace nylon net for vent pipes &man hole cover(vii)Writing letter in bold with white paint on black colour back ground such as sump number, capacity, cleaned on Date & Due on Date etc Note : The contractor shall arrange mobile generatorfor operation of dewatering by high pressure submersible pump (or) Diesel driven high pressure pump and the unit quoted rate is inclusive of rent/hiring charges complete. 319 20000 Gallons capacity at ETI. 320 15000 Gallons capacity at E & ITI. 321 10000 Gallons capacity near SSC. 322 S&F as in repair single core multistrand flexible copper cable of size 25 Sqmm x 1 core , includingof lugs , connecting up with nuts and bolts, insulation tape wrappingetc , the selection of cable as per colour code all as specified and directed Make : Havells /Polycab/RPGAsian 323 Material and labour for removing the submersible pump set of capacity for 7.5 to 15 HP including pipes and submersible cables complete from the exisiting bore well of depth up to 200 mtr by any suitable method i.e either manual.vehicle mounted motorized system and disconnecting the pump motor to locate the faults in presence of Engr-in-Charge, transporting to Wksp and carry out repairs, reassembling, lowering to bore well after repairs, testing and commissioning complete all as specified and directed 324 M&L for taking out, dismantling pump and motor of submersible pump set of capacity for 7.5 to 15 HP to carry out repairs and replacements , duly rewinding and replacing worn out parts, applying one coat of spray painting with synthetic enamel paint of existing colour and testing and inserting in borewell after repair complete all as specified and directed.Note :- (a)The spares shall be measured and paid seperately in the relevent items given below as supply only.(b) Cost of labour for replacement of spares and transportation are deemed to be included in the quoted rate. (c)The pumpset shall be spared for one week for repair from the date of complaint given by AGE/ JE E/M regarding breakdown. Thecontactor is responsible for making alternate arrangement of pump set in case of time required more than one week.(d)In case services affected due to delay in repair of pump set, a penalty of Rs 500 per day will be levied from the contactor.(e)Please note that this penalty is exclusively other then the condition 67 of IAFW-2249 and shall be treated as interim condition of the contract.(f)The decision of the Accepting Officer in this regard shall be final and binding. 325 Supply only GM Bush suitable for 7.5 HP to 15 HP submersible pumpset as per manufacturers design complete all as specified and as directed. 326 Supply only SS coupling bearing suitable for 7.5 HP to 15 HP submersible pumpset as per manufacturers design complete all as specified and as directed. 327 Supply only sleeve MS key for impeller suitable for 7.5 HP to 15 HP submersible pumpset as per manufacturers design complete all as specified and as directed. 328 Supply onlySand Guard suitable for 7.5 HP to 15 HP submersible pumpset as per manufacturers design complete all as specified and as directed. 329 Supply only oil seal thrust bearing suitable for 7.5 HP to 15 HP submersible pumpset as per manufacturers design complete all as specified and as directed. 330 M&L flat three core PVC Insulated & PVC Sheathed Industrial Cable for Submersible Pump Motors 1100 Volt, conforming to IS 694, 6 Sqmm nominal area complete including taking out old unserviceable cable complete all as specified and directed. Make :- Havells/Polycab/Finolex/KEI 331 S & F in repair Over load Relay range of (1.6 -2.5 Amps ) , max-10A (as per sample) for 1.5 HP starter (Dol/Star delta) complete all as directed. 332 S & F as in replacementONload change over switch 4 pole 250Amps in sheet metal enclosure complete all as specified and as directed. make :-Havells /L&T/Indo Asian 333 M & L for servicing of submersible starter by checking and servicing the contactor coil , over load relay coiland any other parts and replacement the burnt out wiring including any modification to pump starter panel by welding,cutting , grinding ,drillingtesting the panel complete all as specified and directedfor the7.5 HP to 15 HP capacity pump setsNotes :-(i) Minor spare parts such as nuts,bolts ,washers ,indicator lamps , start,stop push button and suitable size of copper wire are deemed to be included in quoted rate. 334 Supply and fix as in repair TPNMCB ,415 volts,fixed type ,63 Amp, 50 Hz, with rupturing capacity 10 KA in theexisting pump starter panel including connecting up incoming/out going cables with suitable lugs and testing complete all as specified and as directed. Make: Indoasian/L&T/ Legrand 335 S&F as in repair single core multistrand flexible copper cable of size 16 Sqmm x 1 core , including of lugs , connecting up with nuts and bolts, insulation tape wrappingetc , the selection of cable as per colour code all as specified and directed Make : Havells /Polycab/RPGAsian 336 S & F in repair Over load Relay range of (0.1 -1.5 Amps ) , max- 5A (as per sample) for 0.5 HP starter (Dol/Star delta) complete all as directed . 337 Note :- An amount of Rs 1,91,800.00 on account of credit schedule for schedule A part II shall be deducted from the total amount of BOQ to arrive at the contract sum.
Contract Date : 12 Aug, 2025   |   Contract Value : 99.67 Lakhs
Disclaimer

We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.

Tender Detail
Website https://etender.cpwd.gov.in/login.html
Quantity
MSME Exemption No
Tender Type Open Tender
Startup Exemption Click Here
Competitive Bidding NCB
Similar Tenders
TENDER INSIGHTS

858

Electric Tenders
Live
CLICK TO KNOW MAXIMUM WIN

Tell us about your Product / Services,

We will Find Tenders for you

🇮🇳 +91
TenderDetail
Loading tenders