TDR : 56348462
Central Public Works Department

Tender Brief :

new delhi, Delhi

Maintenance Of Electrical Installation & Fans Maintenance Of Electrical Appliances Hmps Bungalows Under North Avenue New Delhi Sh Replacement Of Post Top Fittings At Various Bungalows

Published: 07 Jul 2026
Opening: 14 Jul 2026
Closing: 14 Jul 2026
Amount: 71214
EMD: 1424
Tender Fee: Ref. Documents


Works Active Harmonic Filter Actuator Aerial Cable Aerodrome Beacon Air Circuit Breaker
2
Days Left
Tender Summary / Eligibility Criteria
Maintenance Of Electrical Installation & Fans Maintenance Of Electrical Appliances Hmps Bungalows Under North Avenue New Delhi Sh Replacement Of Post Top Fittings At Various Bungalows
Documents Download All
d98a14d1-a33c-4d44-814a-d4df6e836cc5
d98a14d1-a33c-4d44-814a-d4df6e836cc5.html
DocumentsList
DocumentsList.zip
No Boq
No Corrigendum
Probable Bidders

AI engine predicts probable bidders to help you bid strategically.

MSME Exception
Explore More →
Technical
Tender involves procurement of high capacity electrical equipment including diaphragm coupling of pump & motor with 90kW capacity at 2900 RPM. The project scope includes installation, testing, commissioning and operational handover.
Previous / Similar Result
BRR : 9629534 Tender For Repair/ Maintenance Of Internal Electrification And External Water Supply At Parundu, External Electric Supply At 4N Det And External Water Supply At 7N Detunder Ge Tirunelveli.; 1 Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc., removing materials to store for keeping in safe custody for taking creditand making good disturbed surfaces of walls, floors etc. 2 Point wiring with 1.5 sqmm (Nominal area) unsheathed multi-stranded copper conductor PVC insulated cable 1100 volts grade single core drawn into and including non-metallic rigid PVC conduit of 20 mm dia/ PVC Casing cappingalong with 1.5 sqmm unsheathed multi stranded copper conductor cable PVC insulated 1100 volts grade as earth continuity conductor connected to common earth dolly fixed to wall/ ceiling roof with and including 1.6 mm thick MS sheet fabricated terminal boxes flush mounted for mounting the switches, sockets, fan regulator etc as required with 3mm thick laminated hylum sheet top cover all as specified and directed for :- 3 One light point controlled by one switch 4 One fan point controlled by one regulator / switch 5 One 3 pin socket outlet 5 amps socket onindependent board 6 One 3 pin socket outlet 5 amps socket on Same Board 7 One light point controlled by two Nosof two way switches 8 One bell/buzzer point controlled by one push button 9 All description as per item No. 2 here-in-before but with 2.5 sqmm cable for one 3 pin socket outlet 15 Amps on independent board with 2.5 sqmm cable as earthing conductor complete all as specified and as directed. 10 Supply and fix in replacement switch flush type single pole two way 5 A 240 Volts complete all as specified and as directed. 11 Supply and fixing in replacement Socket outlet 2 in 1, 3 pin, 5A complete all as specified and as directed. 12 Supply and fix in replacement switch piano flush type single pole one way 5 A 240 Volts complete all as specified and as directed. 13 Supply and fix in replacement switch Socketcombination 2 in 1,5 Amps Flush type 240 Voltscomplete all as specified and as directed. 14 Supply and fix in replacement switch Socketcombination 5 Amps / 16 amps, 5 in 1 flush type 240 Voltscomplete all as specified and as directed. 15 Supply and fix in replacementceiling rose3 ways PVC / Polycarbonate, isolated body complete all as specified and as directed. 16 Supply and fix in replacement Call bell, ding-dong, suitable for working on 230 volts AC supply, single pole, complete all as specified and as directed. 17 Supply and fix in replacementStepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc completeall as specified and as directed. 18 Supply and fix in replacement Bell push flush type5 A 240 Volts complete all as specified and as directed. 19 Supply and fix inreplacement Modular switch 1 way 5A, 1 Module complete all as specified and as directed. 20 Supply and fix inreplacement Modular switch 1 way 16A, 1 Module complete all as specified and as directed. 21 Supply and fix inreplacement Modular bell push ,5 A, 1 Module complete all as specified and as directed. 22 Supply and fix inreplacement Modular Socket 5A-2/3 pin combined 2 Module complete all as specified and as directed. 23 Supply and fix inreplacement Modular Socket5A / 15A - 2 / 3 pin combined 2 Module complete all as specified anddirected 24 Supply and fix in replacement Modular fan regulator step type , 2 Module complete all as specified and as directed. 25 Supply and fix inreplacement Modular switch 2 way 5A, 1 Module, flush type complete all as specified and as directed. 26 Taking down carefully old unserviceable sub main wiring with aluminum /copper conductor cable 4/6 Sqmm in PVC conduit complete removing the materials and taken as credit and making good the disturbed surface of wall / floor etc. 27 Material and labour for sub main wiring with two run single core4 sqmm multi stranded copper conductor FRLS-H PVC insulated unsheathed cable 1100 volts grade and one run of 4 sq mm multi stranded copper conductor FRLS-H cable as earth continuity conductor drawn into and including non-metallic rigid PVC conduit 20 mm dia/PVC casing capping 20 mm including conduit accessories all as specified and directed.Note: Three runs of 4 Sqmm cable and one run of 20mmconduit / casing capping will be measured as one unit length. 28 Material and labour for sub main wiring with two run single core 6 sqmm multi stranded copper conductor FRLS-H PVC insulated unsheathed cable 1100 volts grade and one run of 6 sq mm multi stranded copper conductor FRLS-H cableas earth continuity conductor drawn into and including non-metallic rigid PVC conduit 32 mm dia/PVC casing capping 25 mm including conduit accessories all as specified and directed.Note: Three runs of 6 Sqmm cable and one run of 25 mm conduit / casing capping will be measured as one unit length. 29 Material and labour for sub main wiring with four runs single core 6 sqmm multi stranded copper conductor FRLS-H PVC insulated unsheathed cable 1100 volts grade and one run of 6 sq mm multi stranded copper conductor FRLS-H cableas earth continuity conductor drawn into and including non-metallic rigid PVC conduit 32 mm dia/PVC casing capping 25 mm including conduit accessories all as specified and directed.Note: Five runs of 6 Sqmm cable and one run of 25 mm conduit / casing capping will be measured as one unit length. 30 Supply and fix in replacement Sheet metal enclosures with socket plug top and MCB SPN 20A, 240 volts, with a two pin and earth plug socket complete with one single MCB 20 Amps, 240 volts (for AC )complete all as specified and directed. 31 Supply and fix in replacement sheet metal enclosure powder coated double doorfor Distribution Board, SPN 4 way DB,240 V with detachable Gland Plate, Box Insertion Marks ,Circuit Identification Label ,Neutral Link ,Earth Link , Tin Plated Copper Bus Bar including , Disconnecting electric connections,complete all as specified and as directed. 32 Supply and fix in replacement sheet metal enclosure powder coated double doorfor Distribution Board, SPN 8 way DBwith 200 A bus bar ,240 V with detachable Gland Plate, Box Insertion Marks ,Circuit Identification Label ,Neutral Link ,Earth Link , Tin Plated Copper Bus Bar including , Disconnecting electric connections, complete all as specified and as directed. 33 Supply and fix in replacement sheet metal enclosure powder coated double door forDistribution Board,SPN 12 wayDB ,415 V with detachable Gland Plate, Box Insertion Marks ,Circuit Identification Label ,Neutral Link ,Earth Link , Tin Plated Copper Bus Bar including , Disconnecting electric connections, complete all as specified and as directed. 34 Supply and fix in replacement sheet metal enclosure powder coated double door forDistribution Board,TPN 4 wayDB ,415 V with detachable Gland Plate, Box Insertion Marks ,Circuit Identification Label ,Neutral Link ,Earth Link , Tin Plated Copper Bus Bar including , Disconnecting electric connections, complete all as specified and as directed. 35 Supply and fix in replacement sheet metal enclosure powder coated double door forDistribution Board,VTPN 4 wayDB with IP 43-IK 09 ,disconnecting electric connections, complete all as specified and as directed. 36 Supply and fix in replacementMCB SP 5 A to 32 A, B curve, 10 kA including , Disconnecting electric connections,completeall as specified and as directed. 37 Supply and fix in replacementMCB SPN 32 Amps, C curve 10 kAincluding , Disconnecting electric connections,completeall as specified and as directed. 38 Supply and fix in replacementMCB TP25A - 63 A, C curve 10 kA including , Disconnecting electric connections,completeall as specified and as directed. 39 Supply and fix in replacementMCB TPN 16 A- 32 Amps, C curve 10 kAincluding , Disconnecting electric connections,completeall as specified and as directed. 40 Supply and fix in replacementMCB TPN40A- 100 A, C curve 10 kA including , Disconnecting electric connections,completeall as specified and as directed. 41 Supply and lay earth continuity conductor or main earthing lead fixed to wall on batten or recess or buried in ground or drawn in conduit / conduit pipe or fixed to poles or any other indicted situation for loop earthing etc of galvanised steel earth stripof size 32 X 6mm including taking down old unserviceable earth strip complete for taking into credit complete all as specified and as directed by the Engineer-in-Charge 42 Supply and fix in replacement Lightning Protection Single point air termination aluminum rod 12mm dia 300mm long with base plate complete all as specified and as directed by the Engineer-in-Charge . 43 Supply and fix in replacement Test point terminal box made out of Gun metal or Phosphorous bronze of size 75x75x25mm drilled and screwed including 3 Nos. 8mm dia 25mm long hex head screwscomplete all as specified and as directed by the Engineer-in-Charge . 44 Supply and fix in replacement Aluminium strip of 25x 3.15mm fixed with screws/ clamps / insulators for roof conductors and down conductors above ground level complete all as specified and as directed by the Engineer-in-Charge. 45 Supply and fix in replacement MCCB3 pole 415 volts25 to100 Amps, with rupturing capacity 16 KA complete all as specified and as directed 46 Supply and fix in replacement MCCB3 pole 415 volts125 Amps, with rupturing capacity 16 KA complete all as specified and as directed 47 Taking down geyser of any make/ type and any capacity after disconnecting the water and electric line connections from any height, bringing down to floor, dismantling the Geyser and overhauling by means of repair/replacement of the defective spares, cleaning externally and internally re-assembling the geyser, fixing in same position and testingfor satisfactory working etc complete.Note:Replacement of defective spares shall be measured and paid under relevant item separately. 48 Supply only Neon lamp indicator (Green and Red) 49 Supply only Bottom flange with inlet and outlet pipe (Apparatus plate) 50 Supply only Thermostat conforming to IS 3017 51 Supply only Flexible connection pipe set of two for cold and hot water 52 Supply only Heating element 2.0 KW 53 Supply Siphon assembly 54 Supply and fix Modular switch SP 1 way 16 Amp with indicator complete all as specified and as directed 55 Taking down ceiling fan 1200mm/1400mm sweep from any height and bringing down to floor, dismantling the ceiling fan and overhauling by means of replacing defective ball bearing, bushes, split pins, grease, packing, winding and cleaning externally, re-assembling the ceiling fan and checking, refixing in its position complete all as specified and directed.Note: (i) Rewinding, replacement of bearing and capacitors shall be measured and paid separately.(ii) All other petty repairs used for this work shall be included in the quoted rate. 56 All as per item No.55 but for exhaust fan 300mm including replacing of rusted nut and bolts complete all as specified and directed. 57 All as per item No.55 but for exhaust fan 450 mm including replacing of rusted nut and bolts complete all as specified and directed. 58 Supply and fix ball bearing suitable for any sweep ceiling fan complete all as specified and directed. 59 Material and labour for rewinding with super enameled copper wire including varnishing, drying and connection complete all as specified and directed. 60 Material and labour for painting of ceiling fans at site with synthetic enamel paint by spray painting including filing cavities with filler in one coat after cleaning dust complete all as specified and directed. 61 Supply and fixing exhaust fan heavy duty 250mm sweep plastic body 900RP, 230V, 50 Hz with louvers, cutting the wall and fixing all as specified and directed.(Note Old exhaust fan to be deposited after taking down to MES store) 62 Supply and fix in replacement louvers for exhaust fan of any sizeincluding taking down old unserviceable louvers and removing the material for taking credit complete all as specified and directed. 63 Supply and fix in replacement Condensor 2.5 to 4 mfd for Ceiling/exhaust fan, including taking down old unserviceable material for taking credit complete all as specified and directed. 64 Supply and fixin replacementFlame proof switch socket &plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earthcomplete all as specified and directed. 65 Supply and fixin replacement Switch flame proof rotary type with termination box in LM6, 16A, single pole 250Vcomplete all as specified and directed. 66 Supply and fix in replacement LED lights fitting 1x 20 W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose completeall as specified and directed 67 Supply and fixing LED light fitting in replacement 1x9W/1X10W bulkhead luminaries including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed 68 Supply and fix in replacementLED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed 69 Supply and fix in replacement LED luminaries 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed 70 Supply and fix in replacement round shape 6 watt (6 inch) 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed 71 Supply and fix in replacement round shape 12 watt (8 inch) 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed 72 Supply and fix in replacement square shape 300x30mm size 15 watt220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed 73 Supply and fix LED1x4 feet, 40Watt, recess mounted light fitting environment friendly, new generation, aesthetically designed ultra modern with high transmitive diffuser suitable for indoor spaces complete all as specified and directed 74 Supply and fix LED in replacement vertical mounting integral highbay/medium bay in hangar ceiling at 10 metre height LED IP65lumnnaire,luminous flux 15000 luminous efficacy 150 lmW, IK 08 surge protection luminaries surge protection level until 4kV along with necessary chain, hooks to hold the bolt and hang the light fitting complete all as specified and directed 75 Supply and fix in repairs LED Security light fitting 35 W LEDcomplete with all accessories internally pre wired and connecting up with twin / three core flexible copper conductor cable of suitable size from ceiling rose to fitting etc, including necessary bracket complete all as specified and as directed. 76 Supply and fix in replacement LED light fitting 2x 16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size including all accessoriescomplete all as specified and as directed. 77 Providing comprehensive annual maintenance periodical/preventive maintenanceincluding annual maintenance of cooling appliances ( Split type Air Conditioners, Water coolers, Refrigerators and Deep Freezers) as per manufacturer specificationby providing one AC/Refrigeration mechanic including replacement ofcomponents as listed in subsequent items here in after. The maintenance of cooling appliances includes the following:-(a) Cleaning of coil unit with dust blower, lubricate the indoor and outdoor fan motor with oil.(b) Cleaning of air filters, indoor unit grillSupply and fixingilters through air blower.(c) Checking and cleaning the drain connection and air filter periodically, washing of coil with ventiklean solution once in a contract period.(d) Check and replace the refrigerant pipe once in a contract period or as and when required.(e) Check and repair the minor electrical fault in incoming supply.(f) Check and replace the water PVC pipe.(g)Replacementof faulty spares/components(h) Carry out the monthly, quarterly and annual maintenance of all cooling appliances of any make & capacity with job card and making the Cooling Appliances functional(Each Job contains 3 Complaints) 78 Supply only the following new items for 1.5 / 2.00 Ton CapacitySplit type AC including testing and commissioning etc complete all as directed. 79 Capacitor 36/45/50 MFD. 80 Air filters. 81 Outdoor fan motor 82 Indoor fan motor 83 Indoor blower 84 Copper condenser coil unit (for A/C) 85 Indoor motor capacitor 2.5 MFD. 86 Outdoor fan motor capacitor 3 to 6 MFD 87 Non return valve (For gas top up charging) 88 Remote control suitable forinverter model Split AC. 89 Electronic components for repairs to PCB 90 PCB board suitable for indoor unit of Inverter model split AC 1.5/2.0 TR . 91 PCB board suitable for outdoor unit of Inverter model split AC 1.5/2.0 TR . 92 Copper pipe of size 1/2 for suction line with foam insulation 93 Copper pipe of size 1/4 for discharge line with foam insulation 94 Swing Motor for indoor unit 95 Supply and fixPVC insulated unsheathed cables of size 2.5 sqmm 3 core multi-stranded Copper conductor wire suitable for AC complete all as specified and as directed. 96 Supply and fixMetal plug top for AC 97 Supply and fixing compressor including pumping out oil, cleaning the refrigeration system with CO2 and charging refrigerant gas (M-22/F-22) providing NRV for further topping up of gas and re-fixing in the position including complete testing and commissioning all as directed for the following appliances :- 98 Split type AC 1.5 Ton capacity. 99 Material and labour for SPN enclosure with two pin and earth plug and socket with 240 volts 20 Amp SPMCB, complete all as specified and directed by Engr-in charge. 100 Supply and fix in repairs LED Security light fitting 25 W LEDcomplete with all accessories internally pre wired and connecting up with twin / three core flexible copper conductor cable of suitable size from ceiling rose to fitting etc, including necessary bracket complete all as specified and as directed. 101 Supply and fix in replacement flat panel 36 watt 2x2 feet 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed 102 Excavating in trenches, not exc 1.5m wide and not exc 1.5m in depth; for laying pipes and getting out in any type ofsoil, complete all as specified 103 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil, complete all as specified 104 Removing excavated soils n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and as directed by the Engineer-in-Charge. 105 Spreading of riddled earth obtained from trenchesfor cable cushioning on top and bottom of cable as specified for cable protection complete all as specified and directed. (Note: Only punned thickness of riddled earth shall be measured) 106 Supply and laybricks in trenches , common burnt clay building bricks, subclass `B’ designation 75, old size ,with width equal to thelength of the brick; complete all as specified and directed. 107 Supply and fix in replacement MCCB4 pole 415 volts63 Amps, with rupturing capacity 16 KA complete all as specified and as directed 108 Supply and fix in replacement MCCB4 pole 415 volts100 Amps, with rupturing capacity 16 KA complete all as specified and as directed 109 Material and labour in replacement of GI pipe light grade of size 80mm diafor protection of UG cable on walls/under floors/road crossings/in trenches complete all as specified and as directed by the Engineer-in-Charge . 110 Servicing of high mast light control gear suspension system with stainless steel wire rope guage and double drum winch with luminaries mounting arm pulley assembly complete all as specified and directed by Engr-in-charge. 111 Supply and fixing in replacement LED flood light 150Watt 230V AC outdoor type with thermal management in multiple optics and equipped with IP6 protectionwith impact and corrosion resistant complete with driver and lamp complete all as specified and directed by Engr-in-charge. 112 Supply and lay LT under ground cable 1100 volts grade Cross linked Polyethylene (XLPE) insulated PVC Sheathed Cables 3.5 core 70 sqmm, armoured multistranded heavy duty electric cable with aluminium conductor laid in trenches/ duct / walls including cable gland and lugs on both end termination including laying, connecting to various switches inpanel board, testing and commissioning complete all as directed & as specified. 113 Supply and fixing L bus bar box outdoor type made up of MS sheet 3mm thk of size 600x500x300mm CPRI approved with supporting angle of size 50x5xmm, 800mm long with nut, bolts and washers of suitable size for fixing on ground with PCC 1:3:6 mix, 20mm aggregate for foundation providing Aluminum bus bar 400m long and 40x5mm thick, 04 nos with supporting insulators and colour coded PVC sleeves including necessary bottom plat whole for entry o cables complete all as specified and directed. 114 Supply and fix in replacementGI tubingmedium gradeincluding provision of necessary fittings like Tee,Bend,Socket,Elbow, Short pieces connectors, plugs, unions, etc and accessories laid in trenchesall as specified and directed by Engineer-in-Charge of following bore sizes:- 115 (a) 20 mm bore steel tubing 116 (b) 25 mm bore steel tubing 117 (d) 40 mm bore steel tubing 118 (e) 50 mm bore steel tubing 119 (f) 80 mm bore steel tubing 120 Supply and FixingGI tubingmedium grade including provision of fittings like Tee,Bend,Socket,Elbow, Short pieces connectors, plugs, unions, etc and accessories on walls/roofs all as specified and directed by Engineer-in-Charge of following bore sizes:- 121 (a) 20 mm bore steel tubing 122 (b) 25 mmbore steel tubing 123 (d) 40 mm bore steel tubing 124 (e) 50 mm bore steel tubing 125 Monthly testing of potable water samples for checking fitness for drinking purposeat the district water testing lab complete all as specified and directed. 126 Monthly testing of raw water/potable water samples for checking fitness for domestic consumption at the district water testing lab complete all as specified and directed. 127 Supply and fixing of gun metal gate valve, painted finish, with forged brass spindle and iron wheel head, screwed both ends internally IS-778 marked, Class-2,for iron pipe of following sizes complete all as specified and directed. 128 (a) 20 mm bore 129 (b) 25 mmbore 130 (c) 32 mmbore 131 (d) 40 mm bore 132 (e) 50 mm bore 133 Supply and fix in repairbrass float valve, ISI marked high pressure with polythene float and fly nut complete, screwed of following size / bore including necessary GI fittings such as elbow, reducer, nipple complete all as specified and directed. 134 (a) 20 mm dia 135 (b) 25 mm dia 136 (c) 40 mm dia 137 (d) 50 mm dia 138 Supply and fix Pressure gauge 5 dia, 0 to 14 Kg/cm2 range fixing on delivery pipe of pump set and removing existing defective pressure gauge and taken as credit complete all as specified and as directed. 139 Supply and fixsluice valves flanged end, cast iron body, flanged and drilled and non rising type stainless steel spindlewith nut, long body, class P N 1.6, conforming to IS 14846 of 2000 for following sizesincluding all flange joint with rubber or fiber board, bolts, nuts and washers complete including pumping out accumulated water all as specified and directed by Eng-in-Charge of following sizes. 140 (a) Sluice Valve, Class PN 1.6, 63mm dia 141 (b) Sluice Valve, Class PN 1.6, 80mm dia 142 (c) Non Return Sluice Valve, 80mm dia 143 Supply and fixFoot Valve screwed / flanged including necessary fittings like connectingflanges of following sizes. 144 (a) Foot Valve 50 mm dia 145 (b) Foot Valve63 mm dia 146 Replacement of GI flange having holes(ISI marked) suitable for 40mm bore pipe including jointing material such as rubber gasket bolt units and washers etc in place of unserviceable all as directed. 147 All as per item No.106 above but Suitable for 50 mm bore pipe 148 All as per item No.106 above but Suitable for 80 mm bore pipe 149 Replacement of GI union of both end lock nut screwed with leak proof washer connected to existing GI tubing of 20mm bore completeall as directed. 150 All as per item No.109 above but Suitable for 25 mm bore pipe 151 All as per item No.109 above but Suitable for 40 mm bore pipe 152 All as per item No.109 above but Suitable for 50 mm bore pipe 153 Material and labour forby scraping / cleaning with wire brushes to remove the old painting from pump, motor, coupling guard, MS common base frame and painting with two coats of synthetic enamel paint of approved quality over a coat of red oxide primer as specified below here in after for pump sets:-(a)Motor and pump - Smoke Grey colour (b) Coupling guard and motor air grill - Post office Red colour.(c)Common base frame - Black colour (d)Suction line and delivery line in side pump house - Navy blue colour for fresh water pipe lines. 154 Taking down defective mono block / Centrifugal pump setfrom foundation by opening of coupling and foundation bolts and transporting to workshop for repairing and reassembling after servicing and overhauling complete with oiling/greasing, lubricating the parts including repair / replacement of worn out parts and replacement of base foundation nuts and bolts and re-installing ,necessary electrical connection and testing for satisfactory performance complete all as specified and directed by Engineer - in - Charge.for electric driven pump set of 1 / 2 HP capacity Note:- (i) The rate quoted for this item shall includes labour charge only for main repair and replacement of defective/UNSV spares/accessories. Spares are to measured and paid separately under subsequent items.(ii) Cost of other minor items/spares such as nut, bolts washers, gaskets,etc which are not covered under Sch A but required for effective functioning of the plant shall be deemed to included in this item. (ii) The cost of spares shall be paid under relevant items given below(iii)In case of any damage to thepipes during the time of removal of the pump set ,contractor shall be responsible for repairing the same without any extra cost to the government. 155 Rewinding of motorcoil complete as per IS-396 of 1953 using super enamelled copper wire ofadequate gauge and weight including replacement of all insulation material and terminal lead for power supply and other petty items required for making motor functional. 156 Supply onlyBall bearings (drive and non drive end)Make 157 Supply onlyElectro dynamically balanced bronze impeller 158 Supply onlyImpeller Key 159 Supply onlyWater Seal 160 Supply only Terminal connection with terminal box 161 Supply only Condensor suitable capacity / MFD 162 All as per item No 114 herein before but pump set of capacity 3 HP Note: The cost of spares shall be paid under relevant items given below as Supply only. 163 Rewinding of motorcoil complete as per IS-396 of 1953 using super enamelled copper wire ofadequate gauge and weight including replacement of all insulation material and terminal lead for power supply and other petty items required for making motor functional. 164 Supply only Ball bearing (Drive and Non drive end) 165 Supply only Cooling fan blade 166 Supply only Cooling fan cover with suitable screws 167 Supply only Terminal box with terminal connection 168 Supply only Electric dynamically balanced bronze impeller 169 Supply only Shaft mild steel 170 Supply only Gun Metal bush 171 Supply only Gland cup with bolts and nuts 172 Supply only Flange drilled suitable size with bolts, nuts and washersincluding rubber gasket 173 Supply only Air cock nozzle brass 174 Supply only Shaft coupling 175 Supply only chlorine test kit. 176 Supply only impeller key 177 Supply only water seal 178 Supply only Condensor of suitable capacity/MFD 179 Supply only Calcium Hypochlorite 65% to 70% Chlorine content in granular form (Calcium based Granular disinfectant for water treatmentof drinking water ). Packed in 45 Kgs each Drum. Make:- Sree Rayalaseema Hi Strength Hypo Ltd.(Brand :- PURI CHLOR)or approved by NMPT Committee of E-in-Cs Branch.Note:- The contractormust submit the NSF Certificate of the product, FSSAI Registration and COC (Certificate of Compliance) in original from manufactures by All India Authorized MES Distributor for each batch of product delivered indicating. Including chemical analysis report by all India authorized MES Distributor. Product must have min. 65% Chlorine Contents suitable for Human Consumption. 180 Material and Labour Cleaning valve chamber of any size by removing all unwanted particles such as mud, sand, dust, dirt, decayed leaves etc. and applying two coats of white wash to all internal and external surfaces of valve chamber all as directed by Engineer-in-charge. 181 Material and labour for disconnectany size/ model of pump set from the foundation bed to carry out minor repair work such as greasing, gland rope packing, nut & bolts, washers and flanged and complete the correctrotational alignment for smooth functioning all as directed by the Engr-in- charge. 182 Supply and fix Gland rope (graphite rope ) (size 1/2,1/4,3/4) suitable for pump size 1 HP-5 HPincluding taking out old unserviceable all as directed. 183 Supply and fix Gland rope (graphite rope ) (size 1/2,1/4,3/4) suitable for pump size 2HP-5 HPincluding taking out old unserviceable all as directed. 184 Supply and fix Gland rope (graphite rope ) (size 1/2,1/4,3/4) suitable for sluice valve 63/80mm diaincluding taking out old unserviceable all as directed. 185 Removal of dust and cleaning the Earth pitand washingthe same, applying one coat of white wash , writing the letters such as for Pump set Numberas required at sitewith enamel paint of black colour on pit cover complete all as specified and as directed. 186 Material and labour for Sub main wiring with four runs single core 4sqmm multi stranded copper conductor PVC insulated unsheathed cable 1100 volts grade and two runs of 4 sqmm multi stranded copper conductor cable as earth continuity conductor drawn into and including non-metallic rigid PVC conduit, 25mm dia/PVC casing capping 32 mmand conduit accessories concealed/surface of wall/roof/ceiling etc complete all as specified and directed.Note: Four runs of 4sqmm and two runs of 4 sqmm cable and one run of 25mm dia conduit/casing capping shall be measured as one unit length. 187 Cutting existing bituminous road and excavating in trenches, not exc 1.5m wide and not exc 1.5m in depth by cutting existing bituminous road not exc 10 sq. m on plan and not exc 1.5m in depth and getting out in any type ofsoil, complete all as specified 188 Demolition of cement concrete (unreinforced) in ground floors and pavings n exe 15 cm thickness (below or above ground level) complete all as specified and as directed by the Engineer-in-Charge. 189 Material and labour for 100 mm thick cement concrete 1:2:4 type B-1, using 20mm graded aggregate for making good the disturbed road surface after laying of pipe line over returned filled and compacted earth surface to match with existing road level complete all as specified and as directed. 190 Material and labour for preparation of new steel surface and applying two coats of approved colour synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. 191 Material and labour for attending breakdown complaints like no water supply in service tank, pipe line leakages etc and also removing air lock in OTM/Single living accommodations with help of required tools and man power with items like GI fittings of any size/dia, union, elbow, tee, bend, nipple, socket etc including excavation upto 1.0 cum if required for rectification of leakage of GI pipe all as specified and directed.Note:-(i) Rate of items like union, elbow, nipple ,coupler, bend socket shall be included in the unit quoted rate.(ii) Rate of excavation upto 1 cum shall be included in the unit quoted rate. 192 Taking down defective mono block / Centrifugal pump setfrom foundation by opening of coupling and foundation bolts and transporting to workshop for repairing and reassembling after servicing and overhauling complete with oiling/greasing, lubricating the parts including repair / replacement of worn out parts and replacement of base foundation nuts and bolts and re-installing ,necessary electrical connection and testing for satisfactory performance complete all as specified and directed by Engineer - in - Charge.for electric driven pump set of 5 HP capacity Note:- (i) The rate quoted for this item shall includes labour charge only for main repair and replacement of defective/UNSV spares/accessories. Spares are to measured and paid separately under subsequent items.(ii) Cost of other minor items/spares such as nut, bolts washers, gaskets,etc which are not covered under Sch A but required for effective functioning of the plant shall be deemed to included in this item. (ii) The cost of spares shall be paid under relevant items given below(iii)In case of any damage to thepipes during the time of removal of the pump set ,contractor shall be responsible for repairing the same without any extra cost to the government. Note: The cost of spares shall be paid under relevant items given below as Supply only. 193 Rewinding of motorcoil complete as per IS-396 of 1953 using super enamelled copper wire ofadequate gauge and weight including replacement of all insulation material and terminal lead for power supply and other petty items required for making motor functional. 194 Supply only Ball bearing (Drive and Non drive end) 195 Supply only Cooling fan blade 196 Supply only Cooling fan cover with suitable screws 197 Supply onlyTerminal box with terminal connection 198 Supply only Electric dynamically balanced bronze impeller 199 Supply only Flange drilled suitable size with bolts, nuts and washers including rubber gasket 200 Supply only Air cock nozzle brass 201 Supply only Shaft coupling 202 All as per Slitem No : 152herein before but defective open well submersible pump set of capacity1 HP/2 HP1 Ph, 240 Voltsincluding taking up the pump set fromopen well/UG sump after disconnecting the electrical and pipeline connection, completewithout any damage to the pump set or thepipes and transporting to workshop including repair/replacement of worn out parts, servicing and overhauling complete with oiling/greasing, lubricating the parts and reassembling and painting of submersible pump set with motor with two coat of synthetic enamel paint over a coat of red oxide after clearing and scrubbing and shifting back to bore well, lowering commissioning and testing on full load complete all as specified and directed by Engineer-in-charge.Note: In case of any damage to thepipes during the time of removal of the pump set ,contractor shall be responsible for repairing the same without any extra cost to the government. 203 Rewinding of motorcoil complete as per IS-396 of 1953 using super enamelled copper wire ofadequate gauge and weight including replacement of all insulation material and terminal lead for power supply and other petty items required for making motor functional. 204 Supply only Thrust bearing 205 Supply only Electro dynamically balanced bronze impeller 206 Supply only Gun Metal bush 207 Supply only Gland Cup with bolts and nuts 208 Supply only GI Flange drilled suitable size bolts, nuts, washers and rubber gasket 209 Supply only Shaft Mild steel 210 Supply only Rotor sleeve 211 All as per Slitem No 152 herein before but pump set capacity 5 HP . Note: The cost of spares shall be paid under relevant items given below as Supply only. 212 Rewinding of motorcoil complete as per IS-396 of 1953 using super enamelled copper wire ofadequate gauge and weight including replacement of all insulation material and terminal lead for power supply and other petty items required for making motor functional. 213 Supply only Thrust bearing 214 Supply only Electro dynamically balanced bronze impeller 215 Supply only Gun Metal bush 216 Supply only Gland Cup with bolts and nuts 217 Supply only GI Flange drilled suitable size bolts, nuts, washers and rubber gasket 218 Supply only Shaft Mild steel 219 Supply only Rotor sleeve 220 All as per Slitem No 152 herein before but Non- clogging submersible pump set capacity 7.5 HP . Note: The cost of spares shall be paid under relevant items given below as Supply only. 221 Rewinding of motorcoil complete as per IS-396 of 1953 using super enamelled copper wire ofadequate gauge and weight including replacement of all insulation material and terminal lead for power supply and other petty items required for making motor functional. 222 Supply only Thrust/ball bearing 223 Supply only Electro dynamically balanced bronze impeller 224 Supply only Cooling fan blade 225 Supply only terminal box with terminal connectors 226 Supply only Shaft Mild steel 227 Supply only Gun Metal bush 228 Cleaning the internal and external surface of UG sump / Static water tankof capacity up to 10000 gallons and well by scrapping/brushing and removing all silt dust etc from walls, floors, clean with water and bleaching powder and applying one coat of lime wash to all internal surfaces and complete removal of sand,dust.dirt and other unwanted coatings from the exterior wall surfaces by suitable means and painting with weather proof oil bound distemper to complete side wall and top surface of sump including writing particulars such as capacity of sump, date of cleaning and due date of cleaning etc using white paint on black back ground with height of letter to match with the existing size including painting to incoming and outgoing pipe lines and valves/valve chambers with approved colour (Pipe line exposed above surface) of any size complete all as directed 229 Cleaning the internal and external surface of Shallow well of size 4.50 mtr dia. and 6 mtr depth by scrapping/brushing and removing all silt dust etc from walls, floors, clean with water and bleaching powder and applying one coat of lime wash to all internal surfaces and complete removal of sand,dust.dirt and other unwanted coatings from the exterior wall surfaces by suitable means and painting with weather proof oil bound distemper to complete side wall of shallow well including writing particulars such as depth of shallow well, date of cleaning and due date of cleaning etc using white paint on black back ground with height of letter to match with the existing size including painting topipe lines and valves with approved colour (Pipe line exposed above surface) of any size complete all as directed 230 Cleaning the internal and external surface of deep Open well of size 7-10 mtr dia. and 10-15 mtr depth by scrapping/brushing and removing all silt dust etc from walls, floors, clean with water and bleaching powder and applying one coat of lime wash to all internal surfaces and complete removal of sand,dust.dirt and other unwanted coatings from the exterior wall surfaces by suitable means and painting with weather proof oil bound distemper to complete side wall of shallow well including writing particulars such as depth of shallow well, date of cleaning and due date of cleaning etc using white paint on black back ground with height of letter to match with the existing size including painting topipe lines and valves with approved colour (Pipe line exposed above surface) of any size complete all as directed 231 Cleaning the internal surfaces of Over Head Tank at 45 m height / staging by scrapping down/brushing and removing all silt dirt, algae etc from walls, floors, washing/ cleaning with water and applying one coat of white wash to all internal surfaces of walls and ceilings complete including writing particulars such as capacity of OH tank, date of cleaning and due date of cleaning etc using white paint on black back ground with height of letter to match with the existing size including painting to incoming and outgoing pipe lines and valves/valve chambers with approved colour (Pipe line exposed above surface) of any size complete all as directed all as directed by Engineer-in-charge for 100000 Litres capacity 232 Cleaning the internal surfaces of Over Head Tank at 15 m height / staging by scrapping down/brushing and removing all silt dirt, algae etc from walls, floors, washing/ cleaning with water and applying one coat of white wash to all internal surfaces of walls and ceilings complete including writing particulars such as capacity of OH tank, date of cleaning and due date of cleaning etc using white paint on black back ground with height of letter to match with the existing size including painting to incoming and outgoing pipe lines and valves/valve chambers with approved colour (Pipe line exposed above surface) of any size complete all as directed all as directed by Engineer-in-charge for 15000 Ltr capacity. 233 NOTE FOR SL ITEM NO 188 TO 192 -1. T & P for dewatering UG Sump / Static Tank has to be arranged by the contractor. Rate quoted is inclusive of material and labour required for dewatering. Nothing extra shall be paid separately. 2. All the operations should be executed by trained workers and technicians, properly dressed along with gum boots, safety harness to work as per the direction of Engineer in charge. Contractor shall bring suitable fittings to connect cleanout pipe and suitable length pipe using cleanout facility if available and operational without damaging water tank. Nothing extra shall be paid separately. Contractor shall be responsible for complete cleaning, suction, disposal activity and thereafter. Any damages to water tank during cleaning operation shall be repaired by the Contractor with no cost to MES. Contractor shall ensure and implement safe working conditions for his laborers during execution , all necessary safety measures and harness shall be used before taking-up work. Suitable lighting and ventilation should be provided by the contractor before cleaning of covered tanks. Agency shall be solitary responsible for the lapses in the safety during the work and allied compensations. Nothing extra shall be paid separately, etc. complete as per direction of Engineer In-charge. 234 Supply and fix Three phase direct online starter, suitable for 1 HP - 5 HP Pump/motor including necessary electrical connections and taking down old unserviceable all as directed. 235 Supply and fix Three phase direct online starter , suitable for7.5 HP Pump/motor. including necessary electrical connections and taking down old unserviceable all as directed. 236 Supply and fixSingle phase direct online starter, suitable for0.5 - 2 HP Pump/motor including necessary electrical connections and taking out old unserviceable all as directed. 237 Supply and fix single phase preventer 3 phase 415 voltsincluding taking out old unserviceable all as directed.. 238 Material and Labour Cleaning rain water collection well (depth 3 mtr: meant for collection of rain water and pumping away the collected water by submersible pumps of 7.5 HP during rainy season) by removing all unwanted particles such as mud, sand, dust, dirt, decayed leaves etc. and applying two coats of white wash to all internal and external surfaces of collection well including painting of submersible pumps 7.5 HP and connected pipe lines ( 2 Pump sets in each rain water collection chamber) with synthetic enamel paint of approved colour all as directed by Engineer-in-charge. 239 Supply and fix Gland rope (graphite rope ) (size 1/2,1/4,3/4) suitable for pump size 2HP-5 HPincluding taking out old unserviceable all as directed. 240 Supply and fix Gland rope (graphite rope ) (size 1/2,1/4,3/4) suitable for Sluice valves 63/80mm dia including taking out old unserviceable all as directed. 241 Supply and connecting flat three core, PVC insulated industrial Flat cable for submersible motor, 4 sqmm (Nominal area) with multi stranded copper conductor, 1100 volts grade connected from starter to submersible pump motor complete all as specified and directed. 242 Supply and connecting flat three core, PVC insulated industrial flat cable for submersible motor, 6 sqmm (Nominal area) with multi stranded copper conductor, 1100 volts grade connected from starter to submersible pump motor complete all as specified and directed. 243 Cutting existing bituminous road and excavating in trenches, not exc 1.5m wide and not exc 1.5m in depth by cutting existing bituminous road not exc 10 sq. m on plan and not exc 1.5m in depth and getting out in any type ofsoil, complete all as specified 244 Material and labour for rendering 10mm thickin cement mortar 1:6 on fair faces of brick work or concrete surfaces complete all as specified and as directed by the Engineer-in-Charge. 245 Material and labour for providing cement concrete 1:2:4 Type B0 using 12.5mm graded aggregate as in copings, complete all as specified and as directed by the Engineer-in-Charge. 246 Material and labour for fixing valve chamber cover in replacement, fabricated from MS sheet 3mm thickness, fixing Angle at all sides, with two Nos of hinges and one No. handle made out of MS round bar 10mm dia with necessary locking arrangement complete all as specified and as directed by the Engineer-in-Charge.
Contract Date : 07 Feb, 2026   |   Contract Value : 32.56 Lakhs
BRR : 10822275 Repair Maintenance Of Various E&M Services In Delhi Consumer Forum, Sheikh Sarai , Pay & Account Office Sriniwaspuri, Mla Office , Aam Aadmi Mohalla Clinic And Various Vrec Offices In South Delhi, Under Sub Division Emsd-Ii ( South East ) Giri Nagar, Kalkaji, New Delhi ( Sh:- Replacement Of Various Defective / Outdated Electrical Items - 1 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. ( Make Of Wire :- Havells / Finolex / Rr Kabel / Kei, Make Of Conduit:- Akg / Bec / Nic / Make Of Switch & Modular Box :- Northwest / Legrand / Mk ) 2 Group C 3 Rewiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable And 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable As Earth Wire In Existing Surface / Recessed Steel / Pvc Conduit Including Dismantling As Required. ( Make Of Wire :- Havells / Finolex / Rr Kabel / Kei ) 4 Group C 5 Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. 6 25 Mm 7 Supplying And Fixing Of Following Sizes Of Steel Conduit Along With Accessories In Surface / Recess Including Painting In Case Of Surface Conduit, Or Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. ( Make:- Akg / Nic / Bec ) 8 20 Mm 9 25 Mm 10 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. ( Make:- Kei / Havells / Finolex / Rr Kabel ) 11 3 X 1.5 Sq. Mm 12 6 X 1.5 Sq. Mm 13 3 X 4 Sq. Mm 14 6 X 4 Sq. Mm 15 Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Rcc / Hume / Metal Pipe As Required. 16 Upto 35 Sq. Mm 17 Supplying And Laying Of Following Size Dwc Hdpe Pipe Isi Marked Along With All Accessories Like Socket, Bend, Couplers Etc. Conforming To Is 14930, Part Ii Complete With Fitting And Cutting, Jointing Etc..Direct In Ground ( 75 Cm Below Ground Level ) Including Excavation And Refilling The Trench But Excluding Sand Cushioning And Protective Covering Etc., Complete As Required. 18 63 Mm Dia ( Od-63 Mm & Id-51 Mm Nominal ) 19 Installation Of Exhaust Fan In The Existing Opening, Including Making Good The Damage, Connection, Testing, Commissioning Etc. As Required. 20 Upto 450 Mm Sweep 21 Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. ( Make:- Northwest / Legrand / Mk ) 22 5 / 6 Amps Switch 23 3 Pin 5 / 6 A Socket Outlet 24 15 / 16 Amp Switch 25 6 Pin 15 / 16 Amp Socket Outlet 26 Bell Push 27 Supplying And Fixing Following Modular Base & Cover Plate On Existing Modular Metal Boxes Etc. As Required. ( Make:- Northwest / Legrand / Mk ) 28 1 Or 2 Module 29 3 Module 30 4 Module 31 6 Module 32 8 Module 33 12 Module 34 Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required ( Make:- Northwest / Legrand / Mk ) 35 Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required. ( Make:- Northwest / Legrand / Mk ) 36 1 Or 2 Module ( 75 Mmx75 Mm ) 37 3 Module ( 100 Mmx75 Mm ) 38 4 Module ( 125 Mmx75 Mm ) 39 6 Module ( 200 Mmx75 Mm ) 40 8 Module ( 125 Mmx125 Mm ) 41 12 Module ( 200 Mmx150 Mm ) 42 Supplying & Fixing Suitable Size Gi Box Wih Modular Plate And Cover In Front On Surface Or In Recess Including Providing And Fixing 25 A Modular Socket Outlet And 25 A Modular Sp Mcb, “C” Curve Including Connections, Painting Etc. As Required. 43 Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. ( Make :- Hager / Legrand / Abb / L&T ) 44 Single Pole 45 Single Pole And Neutral 46 Supplying And Fixing Following Rating, Four Pole, 415 V, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 47 63 A 48 Providing And Fixing Following Rating And Breaking Capacity And Pole Mccb With Thermomagnetic Release And Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required. ( Make:- L&T / Legrand / Hager / Abb ) 49 100 A, 16 Ka, Tpmccb 50 200 A, 25 Ka, Tpmccb 51 Supplying And Fixing Call Bell / Buzzer Suitable For Single Phase, 230 V, Complete As Required. 52 Fixing Of Following Ways Surface / Recess Mounting, Vertical Type, 415 V, Tpn Mcb Distribution Board Of Sheet Steel, Dust Protected, Duly Powder Painted, Inclusive Of 200 A, Tinned Copper Bus Bar, Common Neutral Link, Earth Bar, Din Bar For Mounting Mcbs ( But Without Mcbs And Incomer ) As Required ( Note : Vertical Type Mcb Tpdb Is Normally Used Where 3 Phase Outlets Are Required. 53 4 Way ( 4 + 12 ) , Double Door 54 8 Way ( 4 + 24 ) , Double Door 55 Fixing Of 8 / 16 Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 56 Supplying , Installation & Testing & Commissioning Of Surface Mounted Type Led Batten Luminarie Having Power Consumption Not More Than 20 W & Having Efficacy >100 Lumens Per Watt With Integrated Led Driver With High Transitivity Opal Diffuser For Direct Lighting With Providing Flexible Steel Conduit I / C Wiring And Making Connections With 1.5Sq.Mm. Pvc Insulated Frls, Copper Conductor, Single Core Cable Including Loop Earthing With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor, Single Core Cable Complete Etc. As Required. ( Make:- Phillips / Crompton / Halonix ) 57 Supplying. Installation, Testing And Commisstioning Of 900 Rpm 300 Mm Sweep Heavy Duty Exhaust Fan Complete With Louvers / Shutters In The Existing Opening Including Making The Hole To Suit The Size Of The Above Fan Making Good The Damage And Connections Etc. As Reqd. ( Make:- Orient / Havells / Crompton ) 58 Supplying, Installation, Testing And Commissioning Of Isi Marked Ceiling Fan Ultra High Energy Efficient, ( 1200 Mm ) Including Wiring The Down Rods Of Standard Length ( Upto 30 Cm ) With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable Etc. As Required. ( Make:- Orient / Havells / Crompton ) 59 Supplying And Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Rcc / Hume / Metal Pipe As Required. ( Make:- Kei / Havells / Finolex ) 60 3X 10 Sq Mm Xlpe Al.Conductor Armoured Cable 61 Sitc Of 60-70W Led Energy Saving Environmentally Friendly , Long Life, Die Cast, Aluminium Ip65 / Ip66 Street Light Fitting Should Have Power Factor >0.95, Cct-5700-6000K Efficacy >100 Lumen Per Watt With Integrated Led Drivers Including Connection With Suitable Size 3X1.5Sq Mm Frls Pvc Insulated Copper Conductor Cable Etc. Complete As Reqd . ( Make:- Phillips / Crompton / Halonix ) 62 Supplying , Installation & Testing & Commissioning Of Led Post Top Lantern Fittings Not More Than 40W & Having Minimum Lumens 4000 With Ip 65 Protection, Rated Voltage Of 220-240V Ac, Cct - 5700K To 6500K On Existing Pole As Light Source Including Complete With Mounting Arrangement & Including Connection With Suitable Size 3X1.5Sq Mm Frls Pvc Insulated Copper Conductor Cable Etc. Complete As Reqd. ( Make:- Crompton / Trilux / Halonix ) 63 Sitc Of 70-80W Led Energy Saving Environmentally Friendly , Long Life, Die Cast, Aluminium / Toughened Glass Ip65 / Ip66 Flood Light Fitting Should Have Power Factor >0.95, Cct-5700-6000K Efficacy >100 Lumens Per Watt With Integrated Led Drivers Including Connection With Suitable Size 3X1.5Sq Mm Frls Pvc Insulated Copper Conductor Cable Etc. Complete As Reqd. ( Make:- Phillips / Crompton / Halonix ) 64 Sitc Of 34-36 Watt 2X2 Recess / Surface Type Led Fittings Size Suitable For Existing Opening In False Ceiling Having System Efficacy > 100 Lumens / Watt And Colour Temperture Of 5500-6500 Kelvin And Cri >80 And Having Power Factor >0.95, Thd <10% I / C Fixing On The Surface With The Help Of Suitble Size Of Screw And Fastners I / C Connections With 3X1.5 Sq Mm Frls Pvc Insulated Copper Conductor Cable Etc. Complete As Reqd. ( Make:- Phillips / Crompton / Halonix ) 65 Supplying , Installation & Testing & Commissioning Of Surface / Recess Mounted Type Downlighter Luminarie Having Power Consumption Not More Than 15-18 W & Having Efficacy >90 Lumens Per Watt, Having Powder Coated Crca Housing & Crca Front Frame With High Transitivity Opal Diffuser For Direct Lighting I / C Connections With 3X1.5 Sq Mm Frls Pvc Insulated Copper Conductor Cable Etc. Complete As Reqd. ( Make:- Phillips / Crompton / Halonix ) 66 Supplying, Installation, Testing & Commissioning Of Wall Fan Of Sweep Size 400 Mm Suitable To Work On Single Phase 230 Volts 50 Hz. Complete With All Accessories Incuding Connection With 1.5Sqmm Frls Pvc Insulated Copper Conductor Cable Etc. Complete As Reqd. 67 Credit For Dismantle Material 68 Assorted Switch Sockets 69 Assorted Downlighters 70 Conventional Type Tube Light Fittings 71 Defective Ceiling Fans 72 Assorted Exhaust Fans 73 Conventional Type Assorted Flood Lights ( 70 To 125W ) / Gate Light / Street Light 74 Assorted / Worn Out Mcb Alongwith Db Spn 75 Assorted / Worn Out Mcb Alongwith Db Tpn 76 Assorted Mccb 77 Assorted Ms Conduit
Contract Date : Ref. Documents   |   Contract Value : Ref. Documents
BRR : 8149783 Tender For Repair/ Maintenance Of Geysers, Solar Water Heater, Summer Appliances, Dg Set, Amf Panel, Electrical Infrastructure, Periodical Servicing/ Inspection Of Various Earthing System & Certain Misc E/M Works At Aftc, 2 Dc Area, Cqae (We) & Afs East West Jalahalli; 1 Inspection, checking adjustments and minor repairs of storage water heater 25/50 ltr capacity of any type any make vertical/ horizontal type which includes the following :-(a) Inspection, taking out of drain plug & dewatering and re-fixing the same complete all as directed .(b) Checking water tightness of storage tank . (c) Checking stop cocks with outlet/inlet pipe of geysers, pressure reducing valves etc to ensure free movement of water and easy functioning of parts.(d) Inspecting over flow vent pipe connections to ensure water-tightness and proper flow.(e) Checking and correct earth continuity of electrical items.(f)Checking functioning of heating elementand correct setting adjustment of thermostat.(g) Adjustment of reducing valves, checking of dead weight type high pressure release valve and visual check of fusible plug for its intactness.(h) Replacement of defective spares shall be measured and paid under relevant items mentioned below separately as supply and fix. 2 Note : The following deemed to be inclusive in quoted rate :- 3 The above job shall be carried out by a trained electrician having ITI in electrical, documentary proof of the education of tradesman shall be produced to the Engr-in-Charge before commencement of work. 4 In case of major defects, entire job shall be completed within 15 days from the date of registration of complaint, failing which penalty charges @100/- per day shall be recovered. 5 In case of minor defects, entire job shall be completed with in 12 hrs from the time of registration of complaint, failing which penalty charges @ 50/- per job shall be recovered. 6 The entire job will be carried out in entire area of Air Force stn Jalahalli 7 All types of T&P, PVC insulation tape, minor nuts, bolts, washers etc required for maintaining the services shall be provided by contractor without any extra cost to the department. 8 Supply and fixingHeating element1.5 KW 230 volts (ISI marked) suitable for 25/50 ltrs geysers any type and any make including taking down old one including washer/ packing suitable complete all as specified and as directed. 9 Supply and fixingPVC connection for hot/ cold water made of double layer nylon braided and fabric at a pressure of 6kg/sq cm at both ends, 450 mm long, heavy duty with CP brass adopters, washers, suitable for 15 mm bore pipe including taking down existing one complete all as specified and as directed. 10 Supply and fixingin replacement pressure relieving valve CP brass confirming to relevant IS with washer suitable for 15mm bore GI pipe suitable for 25/50 ltrs geysers complete all as specified and as directed. 11 Material and labour forCutting and screwing existing steel water tubing 15/20/25 mm bore for addition /alteration required for connections to geysers etc including taking down existing one complete all as specified and directed. 12 Supply and fixingin replacement thermostat switch range of 30-80 degree celsiussuitablefor geysers of 25/50 ltrs capacity (ISI marked) complete all as specified and as directed. 13 Supply and fixingin replacement brass non return valves, screwed down, high pressure, screwed both ends for 15mm bore iron pipe or for union, ISI marked, complete all as specified and as directed. 14 Supply and fixingOuter body of MS sheet not less than 20 gauge suitable for 25 ltr geyser with white synthetic enamelled paint including taking down existing one complete all as specified and as directed. 15 Material and labour for Grouting 4 Nos of M12 X100mm bolt in stone /brick masonry wall with 1:4 CM suitable for hanging geysers complete all as specified and as directed. 16 Supply and fixing Indicator lamp for geyser 25/50 ltr capacity ofcolour green & red complete all as specified and as directed. 17 Supply and fixingHeating element2.0 KW 230 volts, ISI marked suitable for 25/50 ltrs geysers of any capacity ,any type and any make including taking down old one including washer/ packing suitable complete all as specified and as directed. 18 Supply and fixingin replacement bottom cover of MS sheet 20 gauge suitable for 25 ltrs capacity geysers and providing a coat of red oxide to inner surface and applying one coat of synthetic enamel paint by spray painting to outer surface complete all as specified and as directed. 19 Material and labourfor painting of outer surface of 50 ltrs storage type water geysers after cleaning of dust & other organic/inorganic materials if any and applying one coat of synthetic enamel white paint by spray painting and writing MES No. on the geyser complete all as specified and as directed. 20 Taking down carefully storage water heater (geyser) 25 ltr capacity of any type, any make from the location by removing the electric & water supply connection and shifted to work shop/MES store yard for repair and re-installation at any location including Supply and fixingin repair of heavy duty pin type fastener 4 long and making necessary inlet/outlet electric & water supply connection from existing source to geyser complete all as specified and as directed.Note :- Adjustment of reducing valves, checking of dead weight type high pressure release valve and visual check of fusible plug for its intactness. 21 Supply and installwater heater storage type (Geyser) vertical of capacity 25 Ltr, suitable for high pressure up to 8 barpowder coated metal body, temperature indicating dial , glass line coated tank, magnesium anode,efficient long life copper heating element, wattage 2 KW electrically operated, AC 230 Volt, BEE5 Star Rated with complete fittings/partsand accessories for fixing on wall/surfaceall as per site requirement andspecified anddirected Make:- Bajaj / Racold / Havells 22 Material and labourfor painting of outer surface of 25 ltrs storage type water geysers after cleaning of dust & other organic/inorganic materials if any and applying one coat of synthetic enamel white paint by spray painting and writing MES No on the geyser complete all as specified and as directed. 23 Taking down carefully storage water heater (geyser) 50 ltr capacity of any type, any make from the location by removing the electric & water supply connection and shifted to work shop/MES store yard for repair and re-installation at any location including Supply and fixingin repair of heavy duty pin type fastener 4 long and making necessary inlet/outlet electric & water supply connection from existing source to geyser complete all as specified and as directed.Note :- Adjustment of reducing valves, checking of dead weight type high pressure release valve and visual check of fusible plug for its intactness. 24 Dismantling carefully solar storage water heating system of 100/200/300 Ltr capacity any type for following works withtestingand refixing the same in original position making all water/ electric connection to entire satisfaction of Engineer-in-charge after repair as under :-(a) Inspection, opening, of all parts,descaling, washing of inner tankwith chemical solution and cleaning ofouter cover storage tank.(b) Checking water tightness of storage tank after cleaning.(c) Checking and correcting earth continuity of electrical items.(d) Adjustment of reducing valves, checking of dead weight type high pressure release valve and visual check of fusible plug for its intactness. (e) Replacement of damaged solar cells(f)Necessary T&P such as ladder, helper shall be contractor responsibility. 25 Note : The following deemed to be inclusive in quoted rate :- 26 The above job shall be carried out by a trained electrician having ITI in electrical, documentary proof of the education of tradesman shall be produced to the Engr-in-Charge, before commencement of work. 27 In case of major defects, entire job shall be completed within 15 days from the date of registration of complaint, failing which penalty charges @ Rs. 500/- per day shall be recovered. 28 In case of minor defects, entire job shall be completed with 12 hrs from the time of registration of complaint, failing which penalty charges @ Rs. 100/- per job shall be recovered. 29 The entire job will be carried out in entire area of Air Force stn Jalahalli 30 Necessary T&P such as ladder, helper shall be contractor responsibility. 31 All types of T&P, PVC insulation tape, minor nuts, bolts, washers etc required for maintaining the services shall be provided by contractor without any cost to the department. 32 Supply and replacement of solar tube as per existing type complete all as specified and directed. 33 Supply and fixingin replacement thermostat switch suitable for solar water heater of any make and size complete all as specified and as directed. 34 Supply only solar cells to replace the damaged cells in thesolar panel for solar water heater 200 Ltr capacitycomplete all as specified and directed. 35 Gasket setfor solar water heater panel suitable for 100Ltr capacity complete all as specified and directed. 36 Supply and fixingin replacement bib taps, cast copper alloy, with crutch or butterfly handle, chromium plated, fancy type, screwed down, screwed for 15mm bore iron pipe, ISI marked, complete all as specified and as directed. 37 Supply and Fix in replacement of solar water heater tank 100 ltr capacity tank should be 1.60 mm thickness low carbon steel with porcelain coating, outer tank should be 0.4 mm thickness stainless steel 202 grade Non Magnetic grade, insulation in PUF 50mm including provn for suitable solar tubes complete all as specified and directed.Note :- Solar tubes shall be measured and paid separately 38 Supply and replace solar panel glass suitable for 100 ltrs capacity solar water heater with gasket complete all as specified and directed. 39 Supply and fixing Stop valves, 15 mm bore of pipe fancy type, chromium plated , high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed. 40 Supply only solar cells to replace the damaged cells in thesolar panel for solar water heater 100 Ltr capacity complete all as specified and directed. 41 Supply and fix in replacementrotational moulded polyethylene water storage tank of 300 litres capacity three layered HDPE water storage tanks cylindrical vertical with closed top as per IS 12701-1996 hoisted and fixed in position, including provn of inlet pipe, over flow pipe, washout pipe etc complete all as specified and directed. 42 Material and labourforStaging / steel frame work for Solar water tanks using standard mild steel sections like angle iron / MS pipe / flat iron / sheets etc using steel of Fe 410-W (Gde E-250) quality - A including necessary welding suitable to keep 300 ltrs PVC water tank in repairs complete all as specified and directed. 43 M&L for Preparing new steel surfaces of any description over 10cm in width or girth , not otherwise described and applying two coats of Synthetic enamel Paint over a coat of red oxideprimer complete all as specified and directed. 44 Supply and fixing 15mm bore galvanized steel water tubing, medium grade with all fittings and fixed complete to walls and ceiling or laid in floors including taking up or down old steel tubing and connection complete all as specified and directed.. 45 Supply and fixingin repair 20 mm dia Chlorinated PVC (CPVC) Pipes of pressure rating 10kgf/cm2including fittings like socket / union / Tee / Reducer / Nipple etc complete fixed to wall/ceilings/ in floors etc, complete all as specified and directed. 46 Supply and fixingin repair Chlorinated PVC (CPVC) Gate Valve of size 20 mm dia, (ISI marked) complete all as specified and as directed. 47 Supply and fixingin repair 25 mm dia Chlorinated PVC (CPVC) Pipes of pressure rating 10kgf/cm2including fittings like socket / union / Tee / Reducer / Nipple etc complete fixed to wall/ceilings/ in floors etc, complete all as specified and directed. 48 Supply and fixingin repair Chlorinated PVC (CPVC) Gate Valve of size 25 mm dia,( ISI marked) complete all as specified and as directed. 49 Supply and fixingin repair 32 mm dia Chlorinated PVC (CPVC) Pipes of pressure rating 10kgf/cm2including fittings like socket / union / Tee / Reducer / Nipple etc complete fixed to wall/ceilings/ in floors etc, complete all as specified and directed. 50 Supply and fixingin repair Chlorinated PVC (CPVC) Gate Valve of size 32 mm dia,( ISI marked) complete all as specified and as directed. 51 Supply and fixingin repair 40 mm dia Chlorinated PVC (CPVC) Pipes of pressure rating 10kgf/cm2including fittings like socket / union / Tee / Reducer / Nipple etc complete fixed to wall/ceilings/ in floors etc, complete all as specified and directed. 52 Supply and fixingin repair Chlorinated PVC (CPVC) Gate Valve of size 40 mm dia,( ISI marked) complete all as specified and as directed. 53 S&F in repair PVC insulated and FRLS PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, 2.5 Sqmm 3 core,complete all as spcified and directed. Make : Havells/ Polycab/ Plaza 54 Taking down ofexhaust fan any size/capacity after disconnecting cable connection, and refixing same in original position after necessary repair/over hauling including replacement of parts of minor nature such as screws, lugs, insulation tape, nuts, bolts, washers etc after cleaning the metal surface, greasing/lubricant etc to make it functional andmaking connection by replacing PVC insulated unsheathed cable of copper conductor of size 1.5 Sqmm from ceiling rose/ connector fan (minimum 0.50 Mtr length) aredeemed to be inclusive in quoted rate all as specified and as directed. Note:- (a)Rewinding, and materials to be replaced are measured separately.) 55 (b)The above job shall be carried out by a trained electrician having qualified in ITI ( electrician Trade), documentary proof of the education of tradesman shall be produced to Engr-in-Charge before commencement of work. 56 (c)Defective unserviceable part like fan bush,bearing etc. will be paid under respective item here-in-after as supply only through proper documentation. 57 (d)The entire job will be carried out inAir Force stn Jalahalli 58 (e) Necessary T&P such as ladder, helper shall be contractor responsibility. 59 (f)All types of T&P, PVC insulation tape, minor nuts, bolts, washers etc required for maintaining the services shall be provided by contractor without any extra cost to the department. 60 (g)Any fan found defective/not working shall be brought to AGE E/M store yard & re-fixed after repairing. 61 (j)In case of major defects, entire job shall be completed within 10 days from the date of registration of complaint, failing which penalty charges @100/- per day shall be recovered. 62 (k) In case of minor defects, entire job shall be completed with 12 hrs from the time of registration of complaint, failing which penalty charges @ 50/- per job shall be recovered. 63 Supply only 3.15 mfd capacity exhaust fan condenser complete all as specified and directed. 64 Supply only fan bush of suitable size for exhaust fan of the any sweep complete all as specified and directed. 65 Supply only fan bearing of suitable size for exhaust fan of 250mmsweepincluding greasing complete all as specified and directed. 66 Supply only metal louvers of suitable size for exhaust fan of the 250mmsweep complete all as specified and directed. 67 Supply only 2.5 mfd capacity ceiling /exhaust fan condensers complete all as specified and directed. 68 Supply only fan bearing of suitable size for exhaust fan of 300mmsweepincluding greasing complete all as specified and directed. 69 Supply only metal louvers of suitable size for exhaust fan of the 300 mmsweep complete all as specified and directed. 70 Supply only 4 mfd capacity ceiling /exhaust fan condensers complete all as specified and directed complete all as specified and directed. 71 Supply only fan bearing of suitable size for exhaust fan of 450mmsweepincluding greasing complete all as specified and directed. 72 Supply only metal louvers of suitable size for exhaust fan of the 450 mmsweep complete all as specified and directed. 73 M&L for cutting of hole through stone wall with the help of Core cutting machineincluding providing, fixing and removing shoring,cleaning,internal plastering and removing surplus hard core,rubbish not exceeding 50 mtrs including fixing of exhaust fan of size 250-450 mm all as specified and as directed. 74 Supply and fixingExhaust fan250 mm sweep 230/ 240 volt AC single phase PVC body1400 RPM including necessary nut, bolts / screws including taking down existing one writing MES No with synthetic enamel paint all specified and directed. Make-Havells /bajaj/ Crompton Greaves.Note:-Old Unserviceable Exhaust fan shall be deposited to MES store yard. 75 Material and labour for winding of Exhaust fan 250mm sweep of any make with super enamelled copper winding wire of existing gauge (wt of copper winding wire per fan 250 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size not less than0.75 mm of length not more than one meter with each fan complete all as specified and directed. Note :- (i)Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit schedule. 76 M&L in repairfor stainless steel wire cloth 0.63 mm dia of wire and average width of aperture 1:40 mm for covering of exhaust fan hole in wall of size 450 mm X450 mm with PVC/woodenbeading fixed on wall including necessary fixing arrangement up to hight 11 mtrcomplete all as specified and directed.Note : All safety measures is the responsible of the contractor 77 Supply and fixingExhaust fan 300 mm sweep 230/ 240 volt AC single phase PVC body 1400 RPM including necessary nut, bolts / screws including taking down existing one writing MES No with synthetic enamel paint all specified and directed. Make-Havells /bajaj/ Crompton Greaves.Note:-Old Unserviceable Exhaust fan shall be deposited to MES store yard. 78 Material and labour for winding of Exhaust fan 300mm sweep of any make with super enamelled copper winding wire of existing gauge (wt of copper winding wire per fan 250 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size not less than0.75 mm of length not more than one meter with each fan complete all as specified and directed. Note :- (i)Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit schedule. 79 M&L for cutting of hole through brick wall with the help of Core cutting machineincluding providing, fixing and removing shoring,cleaning,internal plastering and removing surplus hard core,rubbish not exceeding 50 mtrs including fixing of exhaust fan of size 250-450 mm all as specified and as directed. 80 Supply and fixingExhaust Fan 300 mm sweep, 230/240 volt AC single phase, heavy duty,1400 RPM, corrosion less mild steel body of motor, suitable hold fast with necessary nut, bolts / screws with louver including taking down existing one,writing MES No. with synthetic enamel paint all specified and directed. Make- Havells /Bajaj/ Almonard.Note:-Old Unserviceable domestic exhaust fan shall be deposited to MES store yard. 81 M&L for repair louver made of galvanised steel suitable for 300 mm size exhaust fan, fixed on wall including necessary fixing arrengement up to height 11 mtrcomplete all as specified and directed.Note : All safety measures shall be the responsible of the contractor. 82 Supply and fixingExhaust Fan 450 mm sweep, 230/240 volt AC single phase, heavy duty,1400 RPM, corrosion less mild steel body of motor, suitable hold fast with necessary nut, bolts / screws with louver including taking down existing one,writing MES No. with synthetic enamel paint all specified and directed. Make- Havells /Bajaj/ Almonard.Note:-Old Unserviceable domestic exhaust fan shall be deposited to MES store yard. 83 Material and labour for winding of Exhaust fan 450mm sweep of any make with super enamelled copper winding wire of existing gauge (wt of copper winding wire per fan 250 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size 0.0076mm of length not more than one meter with each fan complete all as specified and directed. Note :- (i)Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit schedule. 84 Taking down ofwall mounted/Pedastal fanof size 400/450mm after disconnecting cable connection, and refixing same in original position after necessary repair/over hauling .(Note:- Repair, rewinding, over hauling and materials to be replaced are measured separately.) 85 Supply only fan bush of suitable size for wall mounted/Pedastalfan of the any sweep complete all as specified and directed. 86 Supply only fan bearing of suitable size for wall mounted/Pedastal fan of 400 mmsweep complete all as specified and directed. 87 Material and labour for winding of wall mounted fan400mm sweep of any make with super enamelled copper winding wire of existing gauge (wt of copper winding wire per fan 350 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of sizenot less than0.75 mm of length not more than one meter with each fan complete all as specified and directed. Note :- (i) Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit schedule. 88 Material and labour for winding of wall mounted/Pedastal fan450mm sweep of any make with super enamelled copper winding wire of existing gauge (wt of copper winding wire per fan 350 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size not less than0.75 mm of length not more than one meter with each fan complete all as specified and directed. Note :- (i) Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit schedule. 89 Removing the window/ split type AC of 1.5/ 2 ton capacity of any make from any location for carrying out servicing complete as and when directed and installing back at original location, testing and commissioning complete all as specified and directed.Note :- The rate of following deemed to be included in quoted rate :-a) Cleaning the body, evaporator and condenser with detergent, combing the pins and flushing with air blowerb) Checking electrical connection, cleaning, Greasing, oiling, fan/blower motor, cleaning of air filter with blowerc) Wrapping suction and discharge pipe with foam insulation and white roll ,changing drainage pipe when necessary d)The unit rate quoted by the tenderer inclusive for Removing, servicing,installation, commissioning and testing of all equipment’s,tools and plants, and back in on final position complete (e) The work shall be done by a specialized team of Engineer/Technicians of OEM.(f) Spares will be measured and paid separately.(g) Refrigerant gas will be measured & paid separately. 90 Supply and fixing Blower of indoor unit suitable for 1.5 Ton / 2 Ton splitAC including taking down existing unserviceable one at any location complete all as specified and directed. 91 Supply and fixing Filter (in replacement) suitable for split type Air Conditioner of any make upto 2 TR capacity, including taking down existing one complete all as specified and directed. 92 Supply and fix Over load relay (in replacement) suitable for split type Air Conditioner of any make up to 2.0 TR capacity, including taking down existing one complete all as specified and directed. 93 Supply and fixingHermetic sealed/Rotory new compressor for 1.5 TR split type AC capacity including disconnecting the electrical and refrigerant connection of defective sealed unit ofsplit type ACof capacity 1.5 Ton and connection of all pipe line & charging of refrigerant and testing complete including taking down existing one complete all as specified and directed. 94 Supply and fix polyurethane foam insulation indoor to outdoor unit suitable for 1.5 Ton to 2 Ton split type A/C of any type and at any locationincluding taking down existing one complete all as specified and directed. 95 Supply and fix discharge valve suitable for 1.5 Ton/2 Ton of split type AC including taking down existing one complete all as specified and directed. 96 Supply and fixing Condenser Fan motor (in replacement) suitable for window type Air Conditioner of any make up to and including 1.5/2.0 TR capacity,including taking down existing one and complete all as specified and directed. 97 Supply and fix Suction valve suitable for 1.5 Ton/2 Ton of split type AC of existing make complete all as specified and directed. 98 Supply and fixing Blower motor (in replacement) suitable for split type Air Conditioner of any make up to 2 TR capacity including taking down existing unserviceable one, complete all as specified and directed. 99 Supply and fixing as in repair offlexible PVC pipe of suitable size for indoor unit drain water of split AC suitable for any type and any capacity complete all as specified and directed. 100 Supply and fixas in repair dummy nut of dia 3/8 suitable for 1.5 Ton/2 Ton of split type AC complete all as specified and directed. 101 Supply and fix dummynut of dia 1/4 suitable for 1.5 Ton/2 Ton of split type AC complete all as specified and directed. 102 Supply and fix as in repair dummy nut of dia 5/8 suitable for 1.5 Ton/2 Ton of split type AC complete all as specified and directed. 103 Supply and fix as in repair dummy nut of dia 1/2 suitable for 1.5 Ton/2 Ton of split type AC complete all as specified and directed. 104 Supply and fixing Remote assembly corded/cordless (in replacement) for any type and size of split type ACs, upto 2.0 TRincluding taking down existing one complete all as specified and directed. 105 Supply and fixingCondenser coil (in replacement) after disconnecting the refrigerant connection of defective condenser coil unit of split type ACupto 2.0 TRand replacing the condenser coil unit connectingthe same unit withrefrigerant connections complete including taking down existing one complete all as specified and directed. 106 Supply and fixing Front grill (in replacement) suitable for split type Air Conditioner of any make up to 2 TR capacity, including taking down existing one all as specified and directed. 107 Supply and fix MS wall bracketsuitable for fixing of out door unit of split type Air Conditioner with necessary nuts, bolts & washers and removing old unserviceable items and making good disturbed surfaces to match with the existing complete all as specified and directed. 108 Supply and fixingHermetic sealed/Rotory new compressor for 2 TR split type AC capacity including disconnecting the electrical and refrigerant connection of defective sealed unit ofsplit type ACof capacity 2 Ton and connection of all pipe line & charging of refrigerant and testing complete including taking down existing one complete all as specified and directed. 109 Supply and fix Condenser coil (in replacement) after disconnecting the refrigerant connection of defective condenser coil unit of split type ACupto 1.5 TRand replacing the condenser coil unit connectingthe same unit withrefrigerant connections complete including taking down existing one all as specified and directed. 110 Supply and fix as in repair PVCinsulated multi stranded copper conductor 3 core 2.5 sq.mm, including connecting up and taking down existing unserviceable cable of any description and size complete all as specified and directed. 111 Supply and fixing Remote sensing unit (in replacement) for upto 2.0 TR split type AC including taking down existing unserviceable one complete all as specified and directed. 112 Supply and fixindoor unit including blower fan , PCB board and all accessories capacity 1.5/2.0 Ton split type A/C including taking down existing unserviceable one any type complete all as specified and directed. 113 Material and labourfor shifting of Air Conditioner, Split type capacity up to 2 TR from existing location to new location as per user requirement and installing, toping up of gas, replacement of copper tubing connecting up, commissioning and testing complete all as specified and as directed.Note :- The rate for following works deemed to be included in quoted rate :-(a)Transportation of air conditioner any type any capacity from one to other location. (b) Fixing only base plate with necessary fixing material on stone / brick walls and as directed (c) Fixing only outdoor and indoor units as required and directed (d) Connecting indoor / outdoors units of split ACs with copper tubes, flairs nuts, warping suction and discharge lines with inclucating materials with necessary fixing arrangements such as bolts, nuts washers and clamps etc. on walls (e) fixing PVC pipes 50mm dia for outlet of outdoor units to drain out dew water with necessary clamps. (f) Fixing of wall mounting voltage stabilizer of 3 KVA to 5 KVA capacity on the wall with necessary fixing arrangements such as bolts, nuts washers and clamps etc on wall. (g) Fixing PVC hose/ PVC pipes of 15mm sizes as reqd at site with necessary junction boxes, PVC bends etc. including two length of PVC copper cables of 4 sqmm size for electrical connection of ACs. (h) No additional payment shall be made for leakage of gas occurring during shifting of Air Conditioner and topping up of required gas.(j)Fixing of copper tubing of qty of required size. 114 Supply and fixing as in repair ofCopper tubing of size 1/2 flare size conforming to relevant IScomplete all as specified and directed. 115 Supply and fixing as in repair ofCopper tubing of size 1/4 flare size conforming to relevant IS complete all as specified and directed. 116 Supply and fixing as in repairof Copper tubing of size 5/8 flare size conforming to relevant IS complete all as specified and directed. 117 Supply and fixing as in repair of Copper tubing of size 3/8 flare size conforming to relevant IScomplete all as specified and directed. 118 Supply and fix PCB board of any make for indoor unit of split AC 1.5 Ton/ 2 Tonincluding taking down existing one complete all as specified and directed. 119 Removing old unserviceablesplit type air conditioner outdoor unit frameand Supply and fixoutdoor unit frame ofthesplit type air conditioner 1.5/2 TR capacity, complete with refixing with all accessories such as hermetically sealedcompressor andcondenser unit, capacitors, relays, fan motor, duly prewired and including connecting of existing refrigerant gas piping, electrical connections and testing etccomplete all as specified and directed. 120 Supply and fix 3 pin metal clad plug top 20 Amps, AC 230 volts for any type of AC including taking down existing unserviceable one complete all as specified and as directed. 121 Supply and fix single phase single pole contactor suitable for 1.5/ 2.0 split type AC complete all as specified and as directed. 122 Supply & fix metal clad switch socket single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20A concealed in walls complete all as specified and as directed.Make : Havells/ Indo asian/ Legrand 123 Supply and fix flair nut of dia 5/8 suitable for 1.5 Ton/2 Ton of split type AC complete all as specified and as directed. 124 Supply and fix flair nut of dia 1/2 suitable for 1.5 Ton/2 Ton of split type AC complete all as specified and as directed. 125 Supply and fix flair nut of dia 3/8 suitable for 1.5 Ton/2 Ton of split type AC complete all as specified and as directed. 126 Supply and fix flair nut of dia 1/4 suitable for 1.5 Ton/2 Ton of split type AC complete all as specified and as directed. 127 Supply and fix flair nut of dia 1/16 suitable for 1.5 Ton/2 Ton of split type AC complete all as specified and as directed. 128 M&L core cutting ofof size 50 mm dia in stonewall with the help of machineand preparing surface to make goodmatching with existing surface coloured complete all as specified and directed. 129 Supply and fix overload protector forsplit AC 1.5/2 Ton TR capacity including taking down existing unserviceable one complete all as specified anddirected. 130 M&L core cutting ofof size 50 mm dia in bricks wall with the help of machineand preparing surface to make goodmatching with existing surface coloured complete all as specified and directed. 131 Material and labour for pressure testing and rectifying the leakages found in the system of window/ split type ACs up to 2 Ton capacity including vacumizing, charging and checking the gas pressure to desire level complete for satisfactory functioning complete all as specified and directed.Note: Toping up of gas shall be measured and paid separately 132 Repair and maintenance of inverter type splitAC of any capacity / any Make from any location including attending breakdown calls, routine maintenance and servicing ,testing and commissioning all as specified and directed here under :-a) Cleaning the body, evaporator and condenser with detergent, combing the pins and flushing with air blower.b) Checking electrical connection, cleaning, Greasing, oiling, fan motor, cleaning of air filter with blower.(c) Testing all copper tube ,joints, leads for any leaking and Top up with the refrigerant gas if necessary.(d)The work shall be done by a specialized team of Engineer/Technicians of OEM. 133 Supply and fix DC blower fan motor for inverter split AC of 1.5 Ton to 2 Ton capacity and including taking down existing unserviceable one of any capacity and at any location complete all as specified and directed. 134 Supply and fixingPCB board of inverter type split type ACfor 1.5 Ton/2 Ton capacity including taking down existing unserviceable one at any location complete all as specified and directed. 135 Taking out, inspection, checking adjustment and minor repair of unserviceable refrigerator 165/175/180/185/190/260/277/286/290/308/310/315/350/360/375 ltr capacity of any type any make for repair/ replacement of defective parts such as condenser, PVC pipe, loose electrical connection etc., cleaning, condenser unit of foreign particle and descaling with carbon di oxide gas to ensure smooth flow of refrigerating gas, reassembling the appliance, testing and placing in original position complete all as specified and as directed .Note :- Repair/ replacement of unserviceable parts shall be measured and paid separately complete all as specified and as directed . 136 Supply and fixingEvaporator coil, suitable for refrigerator of 260 to 308 ltrs any make size and type (in replacement)complete all as specified and as directed. 137 Supply and fixingChiller tray (in replacement) suitable for Refrigerator of any make, 260 to 308 litres capacity,complete all as specified anddirected. 138 Material and labour for Freezer compartment including door and accessories suitable for refrigerator 260, 286,308, 315 and 350 ltrs capacity refrigerator and including taking existing unserviceable one complete all as specified and as directed. 139 Supply and fixinghermetically sealed new compressor (in replacement) for 260 to 308 Ltrcapacity of refrigeratorincluding filling of refrigerant suitable and testing complete by disconnecting the electrical and refrigerant connection of defective sealed unit of Refrigerator compressor of capacity 260 to 308 litres complete all as specified and directed. 140 Supply and fixingVegetable tray (in replacement) suitable for Refrigerator of any make, 260 to 308 litres capacity,complete all as specified and as directed. 141 Supply and fixingin replacement condensing coil for refrigerator of capacity 260 to 308 Ltr complete all as specified and directed. 142 Material and labourfor pressure testing and rectifying the leakage found in the system of refrigerator of capacity 260 to 308 litres including vacuuming and charging the refrigerant gas to the desired pressure and filling new compressor oil etc. complete for satisfactory functioning complete all as specified and as directed.Note:Topping up of gas shall be measured and paid separately 143 Supply and fixingPVC shelf transparent type of tough plastic suitable for refrigerator of capacity 260 to 308 ltrs complete including taking down existing unserviceable one complete all as specified and directed. 144 Supply and fixing superior quality plastic/PVC Ice cube tray for refrigerator of capacity 260 Ltrs to 308 ltrs complete all as specified and directed. 145 Supply and fix in repair electric bulb 20 watt 230v threaded type for refrigerator of Capacity 260 ltrs to 308 ltrs complete all as specified and directed. 146 Material and labourfor pressure testing and rectifying the leakage found in the system of refrigerator of capacity 165 to 260 litres including vacuuming and charging the refrigerantgas to the desired pressure and filling new compressor oil etc. complete for satisfactory functioning complete all as specified and directed.Note:Topping up of gas shall be measured and paid separately 147 Supply and fix in repair magnetic beading for refrigerator of cap 165 ltrs to 335 ltrs complete all as specified and directed. 148 Supply and fixingEvaporator coil, suitable for refrigerator of 165 to 260 ltrs any make size and type (in replacement) complete all as specified and directed. 149 Material and labour for preparing the old painted surface of refrigeratorof capacity 165 litres to 350 litres and spray painting with synthetic enamel paint of approved colour complete all as specified and directed. 150 Supply and fixinghermetically sealed new compressor (in replacement) for 165to 260 Ltrcapacity of refrigeratorincluding filling of refrigerant suitable and testing complete by disconnecting the electrical and refrigerant connection of defective sealed unit of Refrigerator compressor of capacity 165 to 260 litres complete all as specified and directed. 151 Supply and fixingRelay, box type, suitable for refrigerator of any make 165 to 335 litres capacity (in replacement) fixed in repairs, complete all as specified and directed. 152 Supply and fixingChiller tray (in replacement) suitable for Refrigerator of any make, 165 to 260 litres capacity,all as specified and directed. 153 Supply and fixing Freezer compartment including door and accessories suitable for refrigerator 165/175 ltrs capacity refrigerator and including taking down existing one complete all as specified anddirected. 154 Supply and fixingin replacement condensing coil for refrigerator of capacity 165 to 260 Ltr complete all as specified and directed. 155 Supply and fixingin replacement Gasket, suitable for door of Refrigerator of any make, 165 to 350 litres capacity, fixed in repairs all as specified and directed. 156 Supply and fixingMulti capacitors 2 µfd for cooling appliances including taking down existing unserviceable one complete all as specified and as directed. 157 Supply and fixingVegetable tray (in replacement) suitable for Refrigerator of any make, 165 to 260 litres capacity,complete all as specified and directed. 158 Supply and fixingTimer and sensor of Refrigerator including taking down existing unserviceable one complete all as specified and as directed . 159 Supply and fixingCopper capillary tubesuitable forrefrigeratorincluding taking down existing unserviceable one, any description complete all as specified and directed. 160 Supply and fixingFilter of refrigerator including taking down existing unserviceable one complete all as specified and as directed. 161 Supply and fixingThermostat, suitable for refrigerator of any make 165 to 350 litres capacity (in replacement) all as specified and directed. 162 Supply and fixingin replacement condensing coil for refrigerator of capacity 308 to 350 Ltr complete all as specified and directed. 163 Supply and fixinghermetically sealed new compressor (in replacement) for 308 to 350 Ltrcapacity of refrigeratorincluding filling of refrigerant suitable and testing complete by disconnecting the electrical and refrigerant connection of defective sealed unit of Refrigerator compressor of capacity 308 to 350 litres complete all as specified and as directed. 164 Supply and fixingEvaporator coil, suitable for refrigerator of 308 to 350 ltrs any make size and type (in replacement)complete all as specified anddirected. 165 Servicing theVoltage Stabilizer 0.5 KVA to 2 KVA single phaseafter replacing transformer, PCB,u/s electronic parts, setting/testing of buck/boost relay, assembleback & fixing in its original position including testing for proper functioningcomplete all as specified and as directed. 166 Supply and fixingOver load protector for refrigerator including taking down existing unserviceable one any description complete all as specified and as directed.. 167 Supply and fixingStarting relay suitable for refrigerator including taking down existing unserviceable one complete all as specified and as directed 168 Supply and fixingMulti capacitors 2.5 µfd for cooling appliances including taking down existing unserviceable one complete all as specified and as directed. 169 Material and labourfor pressure testing and rectifying the leakage found in the system of refrigerator of capacity 308 to 350 litres including vacuuming and charging the refrigerantgas to the desired pressure and filling new compressor oil etc. complete for satisfactory functioning complete all as specified and directed.Note: Topping up of gas shall be measured and paid separately 170 Servicing theVoltage Stabilizer 4 KVA to 5 KVA single phaseafter replacing transformer, PCB,u/s electronic parts, setting/testing of buck/boost relay, assembleback & fixing in its original position including testing for proper functioningcomplete all as specified and as directed. 171 Supply and fixingMulti capacitors 4 µfd for cooling appliances including taking down existing unserviceable one all as specified and as directed. 172 Taking out, inspection, checking adjustment and minor repair of unserviceable water cooler 40/80/60/120/150/180 ltr capacity of any type any make for repair/ replacement of defective parts such as condenser, PVC pipe, loose water tap, float valve, loose electrical connection etc., cleaning condenser unit of foreign particle and descaling with carbon di oxide gas to ensure smooth flow of water cooler gas, reassembling the appliance, testing and placing in original position complete all as specified and as directed .Note :- Repair/ replacement of unserviceable parts shall be measured and paid separately complete all as specified and as directed . 173 Supply and fixingElectric condenser Fan motor, AC 230 volt, single phase with recommended RPM etc. (in replacement) suitable for water coolerof any make of 150/180 litres capacity, complete all as specified and directed. 174 Taking down corroded bottom portion of water cooler of 150 litres capacity and provision of 14 gauge MS sheet with suitable size angle iron frame work duly welded to the body of the water coolerincluding two coats of synthetic enamel painting over a coat of red oxide primer to match the existing colour all as specified and directed. 175 Supply and fix Stainless steel tray (in replacement) suitable for water cooler of160 to 180 Litres capacity complete all as specified and directed. 176 Supply and fixingDoor gasket (in replacement) suitable for lid of water cooler up to 150 litres capacity, complete all as specified and directed. 177 Supply and fixinghermetic sealed new compressor (in replacement) for water cooler 150 litre/Hr cooling capacityincluding disconnecting the electrical and refrigerant connection of defective sealed unit of storage type water cooler of capacity 150 litres and connection of all pipe line & charging of refrigerant and testing complete including taking down existing one all as specified and directed. 178 Supply and fixingPVC drain out pipe 32 mm dia bore (in replacement) as per existing including providing necessary GI clamps, nut bolt etc.all as specified and directed 179 Supply and fixingSelf closing push type Bib tap 15mm diamade out of cast copper alloy chromium plated (in replacement) suitable for water cooler conforming to ISI mark, including testing and leak proof etc. complete all as specified and directed. 180 Supply and fixingball brass valve high pressure 15mm dia complete fitting such as PVC polythene ball, layer check nut washer etc for water cooler of any capacity including taking down existing one all directed. 181 Supply and fix in replacement of gun metal gate valve 15mm dia including GI nipple including taking down existing one all as specified and as directed 182 Material and labourfor preparing the old painted surface of the water coolers of capacity cap 150 Litres and spray painting with synthetic enamel paint over one coat of red oxide primer including replacement of worn out nut, bolt, washer, screw and writing MES No and capacity all as specified and directed. 183 Material and labourfor pressure testing and rectifying the leakages found in the system of water cooler of capacity 150 litres and vacuuming and charging refrigerant gas and filling new compressor oil etc. complete for satisfactory functioning all as specified and directed.Note:Topping up of gas shall be measured and paid separately 184 Supply and fixingElectric condenser Fan motor, AC 230 volt, single phase with recommended RPM etc. (in replacement) suitable for water coolerof any make of 60/120 litres capacity, including taking down existing one all as specified and directed. 185 Supply and fixinghermetic sealed new compressor (in replacement) for water cooler 60/120 ltr/Hr cooling capacityincluding disconnecting the electrical and refrigerant connection of defective sealed unit of storage type water cooler of capacity 60/120 litres and connection of all pipe line & charging of refrigerant and testing complete all as specified and directed. 186 Material and labourfor pressure testing and rectifying the leakages found in the system of water cooler of capacity 60/120 litres and vacuuming and charging refrigerant gasand filling new compressor oil etc. complete for satisfactory functioning all as specified and directed.Note: Topping up of gas shall be measured and paid separately 187 Taking down corroded bottom portion of water cooler of 40/80 litres capacity and provision of 14 gauge MS sheet with suitable size angle iron frame work duly welded to the body of the water coolerincluding two coats of synthetic enamel painting over a coat of red oxide primer to match the existing colour all as specified and directed. 188 Supply and fixingElectric condenser Fan motor, AC 230 volt, single phase with recommended RPM etc (in replacement) suitable for water coolerof any make of 40/80 litres capacity, complete all as specified and as directed. 189 Supply and fix Stainless steel tray (in replacement) suitable for water cooler of 40/ 80 litres capacity all as specified and directed. 190 Supply and fixingCondensing coil suitable for water cooler of capacity 40/80 ltr/hr cooling capacity (in replacement) complete all as specified and as directed. 191 Supply and fixingEvaporator coil suitable for water cooler of capacity 40/80 ltr/hr cooling capacity (in replacement) complete all as specified directed. 192 Supply and fixinghermetic sealed new compressor (in replacement) for water cooler 40/80 ltr/Hr cooling capacityincluding disconnecting the electrical and refrigerant connection of defective sealed unit of storage type water cooler of capacity 40/80 litres and connection of all pipe line & charging of refrigerant and testing complete all as specified and directed. 193 Material and labourfor preparing the old painted surface of the water coolers of capacity of 40/80 Litres and spray painting with synthetic enamel paint over one coat of red oxide primer including replacement of worn out nut, bolt, washer, screw and writing MES No and capacity complete all as specified and as directed. 194 Material and labourfor pressure testing and rectifying the leakages found in the system of water cooler of capacity 40/ 80 litres and vacuuming and charging refrigerant gasand filling new compressor oil etc. complete for satisfactory functioning all as specified and directed.Note: Topping up of gas shall be measured and paid separately 195 Supply and fixingCarbon (filter) 12” size incl taking down old unsv complete all as specified and as directed. 196 Supply and fix in replacement of filter for water cooler of any size any make complete all as specified and as directed. 197 Supply and fixingMulti capacitors 4.5 µfd for cooling appliances including taking down existing unserviceable one complete all as specified and as directed. 198 Supply and charging of refrigerant gas R-134a to water cooler,refrigerator and deep freezer air conditioner of any type, make and capacity all as specified and directed.(i) Empty cylinder shall be returned to contractor.(ii) Payment shall be made for net weight of gas filled. 199 Material and labourfor repairing the leakage in the steel water tank of water cooler of any capacity by welding brazing/ soldering complete all as specified and directed. 200 Supply and fixingMulti capacitors 6 µfd for cooling appliances including taking down existing unserviceable one complete all as specified and as directed. 201 Material and labourfor taking down of ceiling fan of size 1200/1400mmsweep for safety checking by replacingdefective parts/painting/rewinding and re-fixing the ceiling fan after repairs, all as specified and as directed by Engr-in-charge. (Note:- The replacement of unserviceable items like capacitor, Bearings, Bush, Canopy, down rod etc. shall be made as directed which will be measured and paid separately under respective items as Supply only. However,parts of minor nature such as screws, lugs, insulation tape, nuts, bolts, washers etc after cleaning the metal surface, greasing/lubricant etc to make it functional andmaking connection by replacing PVC insulated unsheathed cable of copper conductor of size 1.5 Sqmm from ceiling rose/ connector fan (minimum 0.50 Mtr length) including cost of labour for above replacement aredeemed to be inclusive in quoted rate all as directed. 202 Note:- The following items shall be deemed to be inclusive in the unit rate quoted against Sl Item No 201(a) In each job, checking the functioning of fan including its connections, cleaning of fan, greasing of fan and mechanical check i.e. tightening of loose screw, nuts, bolts, etc are inclusive in unit quoted rate. 203 (b)The above job shall be carried out by a trained electrician having qualified in ITI ( electrician Trade), documentary proof of the education of tradesman shall be produced to the Engr-in- Charge, before commencement of work. 204 (c)Replacement of unserviceable parts like rubber bush, clamps, bolts, nuts, washers, safety pin, bearing etc shall be paid under respective item here-in-after as supply only through proper documentation. 205 (d)The entire job shall be carried out inAir Force stn Jalahalli 206 (e)Necessary T&P such as ladder, required manpower for taking down and refixing after repair shall be of contractors responsibility. 207 (f)All types of T&P, PVC insulation tape, minor nuts, bolts, washers etc required for maintaining the services shall be provided by contractor without any extra cost to the department. 208 (g)Any fan found defective/not working shall be brought to AGE E/M store yard & re-fixed after repairing. 209 (j)In case of major defects, entire job shall be completed within 10 days from the date of registration of complaint, failing which penalty charges @100/- per day shall be recovered. 210 (k) In case of minor defects, entire job shall be completed within12 hrs from the time of registration of complaint, failing which penalty charges @ 50/- per job shall be recovered. 211 Supply onlyfan bearing suitable forceiling fan 1200mm /1400 mm sweep (bearing with 8 balls shall be used ) Make:- NBC/TATA/SKF 212 Supply only rotor of ceiling fan of any size complete all as specified and directed. 213 Supply onlygun metalbush of suitable size for ceiling fan 1200mm /1400 mm sweep complete all as specified and directed. 214 Supply only fan canopies for ceiling fan size of 1200mm/1400mm sweep complete all as specified and directed. 215 Supply onlydown rod for ceiling fan with 15mm dia (of length not less than 45cm and not more than 60cm) with hanging clamps for ceiling fan complete all as specified and directed. 216 Supply only Rubber reel bushes for ceiling fan of size 1200/1400mm sweep complete all as specified and directed. 217 Supply only steel screw (for fixing of fan blade) as per site requirement for any make of ceiling fan complete all as specified and directed. 218 Supply onlyouter body of ceiling fan of any size complete all as specified and directed. 219 Supply onlydown rod for ceiling fan with 15mm dia (of length not less than 180cm and not more than 210cm) with hanging clamps for ceiling fan complete all as specified and directed. 220 Supply only U clamp for hanging ceiling fan with all nuts, bolts and washers complete all as specified and directed. 221 Supply onlydown rod for ceiling fan with 15mm dia (of length not less than 90cm and not more than 120cm) with hanging clamps for ceiling fan complete all as specified and directed. 222 Supply onlyblades (made of aluminium) suitable for 1200mm sweep ceiling fan of any make with set of screws complete all as specifiedand directed . 223 Supply only safety cotter pins 40mm to 50mm longwith nuts and bolt with washers for ceiling fan of size 1200/1400mm sweep complete all as specified and directed. 224 Supply onlyblades (made of aluminium) suitable for 1400mm sweep ceiling fan of any make with set of screws complete all as specifiedand directed. 225 Supply and fixing in replacement of unserviceableceiling fan 1200mm sweep, energy efficient BLDCISI mark withstar rating 230 Volts AC 50 Hz, single phase including provision of fixing arrangement, nut and bolt andflexible copper cable 3 core of size 1.5 sqmm not less than 0.5 m long complete including taking down existing one, writing MES No with synthetic enamel paint all as specified and as directed. Make : Havells/Bajaj/ Orient.Note:-(a)Old Unserviceable ceiling fan shall be deposited to MES store yard. 226 Material and labour for winding of ceiling fan motor 1200 mm sweep of any make with super enamelled copper winding wire of existing gauge (wt of copper winding wire per fan 350 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size not less than0.75 m of length not more than one meter with each fan complete all as specified and directed. (i) Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit schedule. (ii) taking down of fan, and re hanging measured under item No. 201 separately. 227 Material and labour for winding of ceiling fan motor 1400 mm sweep of any make with super enamelled copper winding wire of existing gauge (wt of copper winding wire per fan 350 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size not less than0.75 m of length not more than one meter with each fan complete all as specified and directed. (i) Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit schedule. (ii) taking down of fan, and re hanging measured under item No. 201separately. 228 Taking down aluminium/copper point wiring & including hard wood battens, surface conduit and board/ blocks etc or through conduits for light, socket or power point, fan point complete and making good the disturbed plaster surfaces of wall, floor, ceilingand painting 2 coat of white wash/distamber to match the existing surface, complete all as specified and directed. 229 M & L for Point wiring with PVC insulated FRLS 1.5 sq mm multi stranded copper conductor cable 1100 Volts grade drawn through and including surface PVC conduit/existing concealed conduit/PVC casing-caping etc as per site requirement onwalls / roofs / floors / ceiling etc and including provision of 1.5 sqmm copper cable as earth continuity conductor and connected to common earth dolly with all fitting and fixing accessories including sunk in cast iron / pressed steel terminal boxes (duly painted with two coats of anti corrosive paint out side and two coats of aluminium paint inside ) with 3.0 mm thick hylum brand laminated white bakelite sheet cover for mounting switches, sockets, fans regulators etccomplete for the following :-Make of wire: Polycab/Plaza/HavellsNote: (a) Switches, sockets outlets, Light fittngs, fans, bells & regulators shall be measured and paid for separetely). 230 All as per item No. 229here in before but forOne light point/fan point controlled by one way 5 Amp switch. 231 All as per item No. 229here in before but forOne light point controlled by two way 5 Amp switch. 232 All as per item No. 229here in before but for one bell point controlled by one way bell push. 233 All as per item No. 229here in before but forOne 3 pin socket out let 5 Ampon the same board 234 All as per item No. 229 here in before but for one switch socket outlet 3 pin 5 Amps on independent board 235 All as per item No. 229here in before but for Wiring with 2.5 Sqmm copper multistranded unsheathed cable and2.5 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently complete all as specified and directed. 236 All as per item No. 229here in before but for Wiring with 4 Sqmm copper multistranded unsheathed cable and4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently complete all as specified and directed. 237 Supply and Fix switch piano flush type 5 Amps240 volts single pole one way, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian 238 Supply and Fix switch piano flush type 5 Amps240 volts single pole two way, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian 239 Supply and Fix switch piano flush type 5 Amps240 volts bell push, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian 240 Supply and Fix shuttered socket outlet 3 pin 5 Amps, flush type, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian 241 Supply and Fix shuttered switch socket outlet 3 pin 5 Amps, flush type, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian 242 Supply and Fix shuttered switch socket outlet 2 in 1, 3 pin, 5 and15 Amps, complete all as specified and directed.Make : Anchor/Havells/L&T/Indoasian 243 S & F ceiling rose surface bakelight two to three terminal complete all as specified and directedMake : Anchor/Havells/L&T/Indoasian 244 S & F in repairfan regulator 120W,for ceiling fan complete all as specified and directed Make : Anchor/Havells/L&T/Indoasian 245 S & F2.5 mfd condensor for ceiling fan, complete all as specified and directed. Make : Epcos/ Asian/ Tyton 246 S & Felectric bell, AC 230 volt, single pole Ding Dong type complete all as specified and directed. Make :Anchor/Havells/L&T 247 M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 Sqmm drawn through in and incl suitable size surface PVC casing caping/PVC Conduit and all accessories fixed to wall/floors along with 4 Sqmm surface PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size.Note: (a)2 runs of 4 Sqmm cable along with one run of 4 Sqmm cable for earth conductor shall be measured as one lengthMake:- Havells/ Polycab/ Plaza. 248 S&F in replacementfactory madepowder coated distribution board VTPN, 4 way double doorMCCB DB includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DBcomplete all as directedMake : Indoasian/ Havells/ Legrand. 249 S&F in replacement distribution board MCCB four pole, 100 Amp ultimate breaking capacity 16 KAconforming to IEC -61439-1, complete all as specified and directed. Make : Legrand/ L&T/ Indo Asian 250 Supply and Fixing in repairs of 4 feet surface mounted batten type luminaire , lumen output of 2000 lumens, high efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle not less than 120° to ensure better uniformity with an operating voltage range from 140V-270V. The luminaire shall have a white extrusion housing with a poly carbonate diffuser to provide uniform light and sleek design with width not more than 22 mm. The luminaire shall have a CRI >80, Color temperature 6500K, THD <10% and PF >0.95,SDCM<5, IP20, IK02, Operating Temperature: -10 TO + 45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-55 HZ. The luminaire shall have flicker content<5% and shall have high and low cut off with auto restart feature.Driver Safety requirement stds: IS 15885-2-13. The luminaire shall be EMI/ EMC compliant and shall have a internal surge protection of 4 KV. The luminaire shall have Class-1 Electrical insulation, Class-B serviceability .The luminaire and driver shall be BIS approved, complete all as specified and directed.Make : Philips/ Bajaj / CG/Havells. 251 Supply and Fixin replacement ofsurface mounted Square/Roundfor LED 18W Watt downlights made of extruded Aluminium housing and high power LED light source withDriver clear diffuser with separate electronic driver with complete accessories all as specified and directed.Make : Philips/ Bajaj/ CG/Havells. 252 S&F in replacement factory madepowder coated distribution board SPN 12 way double door,includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DB conforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian 253 S&F in replacement distribution board MCCB four pole, 63 Amp ultimate breaking capacity 16 KAconforming to IEC -61439-1, complete all as specified and directed. Make : Legrand/ L&T/ Indo Asian 254 S&F in repairs 35/36 W (WH) LED Surface type2x2 ft luminaire with classic design & glare free soft illumination. housing with white high reflection powder coated (RAL9016) CRCA sheet. Glare free, Opal diffuser for symmetrical light distribution fixed in separate CRCA sheet frame held in with housing by screws for easy maintenance. High efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle of 100° to ensure better uniformity. Powered by an independent Isolated, SELF Output electronic LED driver (SMPS based constant current supply) efficiency of 85% with built-in Surge protection 3Kv. System Lumen Output of 3000 lumens.Make : Philips/ Bajaj/CG/Havells. 255 S&F in repairs LED bed side light /wall light/study lightenvironmentel friendly energy effcient of capacity3 W warm whiteetc,inbuilt drivercomplete with all accessories internally pre-wired swing type and including connecting up towith twin core twisted flexible copper conductor cable with suitable size complete all as directed . Make : Bajaj/ Philips / Wipro/CG 256 Supply & Fixing in replacement of electronic LED driver 2/3 W suitable for bed side light fitting as per site requirement complete all as specified and directed . 257 M & L for Point wiring with PVC insulated FRLS 1.5 sq mm multi stranded copper conductor cable 1100 Volts grade drawn into and including concealedrigid non mettalic PVC conduit/casing caping medium grade not less than 19/20 mm ( ISI marked ) with all fitting and fixing accessories including sunk in pressed steel chromium plated terminal boxes, concealed in wall/surface/roofs/floor/ceiling etc as per site requirement and making & matching the existing surface) white bakelite sheet cover for mounting switches, Sockets, Fan regulators etc or modular cover plate with frame including sunken boxes suitableto fix modular cover plate with frame, concealed in wall or 1.5 sq mm multi stranded copper conductor cable as continuous earth wire drawn with wiring and connected to common earth dolly complete all as specified and directed for the following :- Make of wire: Polycab/Plaza/HavellsNote:Blanking plate,Modular cover plate ,Switches, sockets outlets, Light fittngs, fans, bells & regulators shall be measured and paid for separetely). 258 All as per item No. 257 here in before but for one light point/fan/bell point controlled by one wayswitch. 259 All as per item No. 257here in before but for one light point controlled by twowayswitch. 260 All as per item No. 257here in before but for one bell point controlled by one bell push. 261 All as per item No. 257 here in before but for one 3 pin socket out 5 Ampon the same board 262 All as per item No. 257 here in before but for one switch socket outlet 3 pin 5 Amps on independent board 263 All as per Sl No 257 above but Wiring with 2.5 Sqmm copper multistranded unsheathed cable and 2.5 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently etc complete all as specified and directed. 264 All as per Sl No. 257 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently complete all as specified and directed. 265 Supply and Fixmodular switch1 way 6 Amp.1 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor/Indoasian 266 Supply and Fixmodular switch2 way 6 Amp.1 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor /Indoasian 267 Supply and Fixmodular switchbell push .1 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor /Indoasian 268 Supply and Fixmodular Socket, 6A - 2/3 pin combined 2 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor/Indoasian 269 Supply and Fixmodular switch1 way 16 Amp.1 module, complete all as specified and directed. Make :Legrand/ Crabtree/ Anchor /Indoasian 270 Supply and Fix modular Socket, 16A - 2/3 pin combined 2 module, complete all as specified and directed. Make : Legrand/ Crabtree/ Anchor/Indoasian 271 Supply and fix White cover plate with frame,2/3 module 272 Supply and fix White cover plate with frame,4 module 273 Supply and fix White cover plate with frame,8 module 274 Supply and fix White cover plate with frame,6 module 275 Supply and fix White cover plate with frame,12 module 276 S & F Modular fan regulator 120W, 2 Module for ceiling fan complete all as specified and directedMake : Legrand/ Crabtree/ Anchor 277 M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 Sqmm drawn through in and incl suitable size surface PVC casing caping/PVC Conduit and all accessories fixed to wall/floors along with 6 Sqmm surface PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size.Note: (a)2 runs of 6 Sqmm cable along with one run of 6 Sqmm cable for earth conductor shall be measured as one lengthMake:- Havells/ Polycab/ Plaza. 278 S&F in replacement factory madepowder coated distribution board SPN 8 way double door,includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DBconforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian 279 S & F MCB in replacement ofSPN 240 volts 40 to 63 Amps complete including taking down unserviceable fitting complete all as specified and as directed .Make : Legrand/ L&T/ Indo Asian. 280 S&F in replacementfactory madepowder coated distribution board TPN, 4 way double doorMCBDB includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DBcomplete all as directedMake : Indoasian/ Havells/ Legrand. 281 S & F in replacement TPN, MCB 40 to 63 Amp, 240 v, 50 Hz ACsuitable for ‘C’ curve, 10 KA breaking capacitycomplete conforming to IS 8828 of 1996, all as specified Make : Legrand/ L&T/ Indo Asian 282 S&F in repairs 35/36 W( WH) LED recessed type 2x2 ft luminaire with classic design & glare free soft illumination. housing with white high reflection powder coated (RAL9016) CRCA sheet. Glare free, Opal diffuser for symmetrical light distribution fixed in separate CRCA sheet frame held in with housing by screws for easy maintenance. High efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle of 100° to ensure better uniformity. Powered by an independent Isolated, SELF Output electronic LED driver (SMPS based constant current supply) efficiency of 85% with built-in Surge protection 3Kv. System Lumen Output of 3000 lumens.Make : Philips/ Bajaj/CG/Havells. 283 Supply & Fixing in replacement of electronic LED driver 35/36 W suitable for round ceiling light indoor fitting of make Philips/ crompton/ Bajaj, complete all as specified and directed . 284 Supply & Fixing in replacement of electronic LED driver 9/10 W suitable for round ceiling light indoor fitting of make Philips/ crompton/ Bajaj, complete all as specified and directed . 285 S & Fin replacement 7/9 watt LED lamp, complete all as specified and directed. Make : Philips/ Bajaj/ Crompton 286 S&F in replacement factory madepowder coated distribution board SPN 6 way double door,includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DBconforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian 287 S & F in replacement of MCB single pole 240 volts 6 to 32 Amps complete including taking down unserviceable fitting complete all as specified and as directed.Make : Legrand/ L&T/ Indo Asian. 288 S & F in replacement TP, MCB 40 to 63 Amp, 240 v, 50 Hz ACsuitable for ‘C’ curve, 10 KA breaking capacitycomplete conforming to IS 8828 of 1996, all as specified Make : Legrand/ L&T/ Indo Asian 289 Supply and Fixing in repairs of 2 feet surface mounted batten type luminaire , lumen output of 1000 lumens, high efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle not less than 120° to ensure better uniformity with an operating voltage range from 140V-270V. The luminaire shall have a white extrusion housing with a poly carbonate diffuser to provide uniform light and sleek design with width not more than 22 mm. The luminaire shall have a CRI >80, Color temperature 6500K, THD <10% and PF >0.95,SDCM<5, IP20, IK02, Operating Temperature: -10 TO + 45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-55 HZ. The luminaire shall have flicker content<5% and shall have high and low cut off with auto restart feature.Driver Safety requirement stds: IS 15885-2-13. The luminaire shall be EMI/ EMC compliant and shall have a internal surge protection of 4 KV. The luminaire shall have Class-1 Electrical insulation, Class-B serviceability .The luminaire and driver shall be BIS approved, complete all as specified and directed.Make : Philips/ Bajaj / CG/Havells. 290 Refixingexisting serviceable LED light fitting fixture any capacity and of any type complete with all accessories internally pre-wired and including connecting up to ceiling rose with twin core twisted flexible copper conductor cable of suitable size after cleaning all dust etc. completeall as specified and as directed . 291 S&F in repairs 35/36 W (WH) LED recessed type1X4 ftluminaire with classic design & glare free soft illumination. housing with white high reflection powder coated (RAL9016) CRCA sheet. Glare free, Opal diffuser for symmetrical light distribution fixed in separate CRCA sheet frame held in with housing by screws for easy maintenance. High efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle of 100° to ensure better uniformity. Powered by an independent Isolated, SELF Output electronic LED driver (SMPS based constant current supply) efficiency of 85% with built-in Surge protection 3Kv. System Lumen Output of 3000 lumens.Make : Philips/ Bajaj/CG/Havells. 292 S&F in replacement factory madepowder coated distribution board SPN 4 way double door,includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DB conforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian 293 S & F MCB in replacement ofSPN 240 volts 32 Amps complete including taking down unserviceable fitting complete all as specified and as directed .Make : Legrand/ L&T/ Indo Asian. 294 S & F in replacement of MCB single pole 240 volts 40 to 63 Amps complete including taking down unserviceable fitting complete all as specified and as directed .Make : Legrand/ L&T/ Indo Asian 295 Excavation in trenches not exceeding 1.5 mtr in width and not exceeding 1.5 mtr in depth and getting out for laying of cables up to proper level and laying of pipelines etcinsoft/loose soil, complete all as specified and directed. 296 Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick, complete all as specified and directed. 297 Removing surplus excavated material (soil) not exc 50 meter and depositing where directed at a level not exc 1.5 meter above the starting point, complete all as specified and directed. 298 Material and labour for Spreading ribbed soil in trenches as in cable cushioning all as per IS 1255-1983, complete all as specified and directed.Note :- (i)Excavated approved soil shall be ribbed by using sieve to separate composite particles etc. as per IS and refilling in trenches before laying of cable 8 CM and 15 CM after laying of cable. This is then gently punned down to a depth of 10 cm above the top of upper most cable (ii) For the purpose of measurement only punned thickness shall be considered for payment. 299 Material and labour for well burnt bricks ‘B’ class as mechanicalprotection to under ground cables laying with length of the bricks equal to the width of the trench, complete all as specified and directed. 300 Material and labour for Cutting existing road/PCC/Drain for laying of GI or any type of pipe including necessary earthwork, excavation exc 600mm depth but not exc 1mtr depth, 800 mm wide including making good existing surface with 150 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate, complete all as specified and directed. Note :-The tenderer shall take into consideration for following points while quoting rate for this item andthe unit rate is deemed to be inclusive for :-(i) Earth work and excavation in any type of soil(ii) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick ,complete all as specified and as directed.(iii) Removing excavated material out side MD land.(iv)Laying of any type/any bore of pipe in trenches including taking down existing unserviceable pipe. Supply of pipe shall be measured and paid separately(v)150 mm thickPCC 1:2:4 type B1 using 20mm graded stone aggregate as inroad to make good existing disturbed surfaces. 301 Material and labour in repair for 4 core 10 Sqmm XLPE insulated heavy duty electric cable with aluminium single stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells, Polycab, RPG Asian 302 Material and labour in repair for 4 core 16 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells/Polycab/RPG Asian 303 Material and labour in repair formaking straight through joint with suitablejointing kit consisting of water proof adhesivesfor UG cable of size 4 core 10 Sqmm to 16 Sqmm, complete all as specified and directed. 304 Supply only of GI pipe light grade for cable protection of size 50mm bore with fittings, complete all as specified and directed. 305 Disconnecting of burnt/ damaged cables from panels/ junction boxes etc, cutting out the burnt out ends, making new end joints by supply and fixing new aluminium lugs/ insulation tape etc and reconnecting using new nuts/ bolts/ washer etc and restoring three phase and neutral in the junction box, complete all as specified and as directed for thecable sizefrom 10Sqmmto 16 Sqmm 3.5 core of underground LT armoured cables.Note :- Earth work required for extending the incoming/ outgoing cable in junction box/ panel board etc shall deemed to be included in the unit rate quoted. 306 Supply, installation, testing and commissioning LTFeeder pillar box double door CPRI Testedof Size 400X250X350mmsuitable for 3 phase 415 Volts of suitable size out door made out 3.15mm thick CRCA sheet of outdoor of panel with angle iron frame of size 32x32x5mm cubical type complete with aluminium bus bar 100 Amp and including PCC foundation as per site requairment to accomodated to the following.INCOMING(a)MCB TPN32 Amp 10 KA - 01 No. (b)LEDindicating lampR-Y-B - 03 Nos. OUTGOING(a) Weather Proof panelPlug and shocket angled type IP 67three Phase 3P+N +E, 20 Amp - 01 No(b) Weather Proof plug and shocket angled type IP 67 Single Phase 2P+E , 20 Amp- 01 No.(a)MCB TPN20 Amp 10 KA - 01 No. (a)MCB SPN20 Amp 10 KA - 01 No. 307 M &L for PCC (1:3:6) type C1 (using 20mm graded stone aggregate) as in copping to poleincluding necessary form work slightly rounding or squaring, complete all as specifiedand as directed. 308 M & L for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundation and mass concrete for poles and filling around fencing posts etc, complete all as specified and as directed 309 Supply & Erecting Mild steel tubular swaged pole 9 meter long 410, SP-31 complete with cast iron base plate, bracket, finial taper plug, bolt, nuts & screws and painted on both side (internally & externally), external surface painted with two coat of aluminum paint over coat of primer and painting with blackup to 1.5 meter from top of PCC 1:3:6 using 20 mm graded stone aggregate coping white colour paint as in strips of equal width with marking pole numbers by using one coat of synthetic enamel paint including necessary PCC 1:4:8 with 40 mm graded stone aggregate as in foundation and coping as per TD drawing including dismantling of old damaged pole complete all as specified and as directed.Note (i)Excavation, earth work and PCC work for embedding pole shall be measured and paid seperately.(ii) Pole upto 1.5 m top of copping shall be painted with 2 coats of black and white strips alternate 30cm each over one coat of red oxide primer (iii) Steel tubular pole above 1.5 m shall be painted with 2 coats of aluminium paint over a coat of red oxide primer. The rate for above items shall be deemed to be inclusive in the quoted rate. 310 Supply and fix in repair weather proof PVC junction box approved by CPRI for street light control box made out of not less than 2mm thick and size 250mm x 200 mm x 105mm (approx) complete with hinged door locking arrangement and consisting of 2 Nos of suitable size cable glands consisting of 01 No. panel mounted connector 4 pole 32A-1 No, MCB SP 6A 10KA-01No, including connecting up with the electrical connections and fixing with clamps etc complete and all as specified anddirected. 311 Supply and fix 1100 Volts grade heavy duty flat weather proof twin core cable of size 4 Sqmm with multistrand aluminium conductor including taking down of old one complete all as specified and directed. Make: Plaza/Polycab/ Finolex/Havells 312 Supply and fixing in repair LED flood light 150 watt made up of die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP 66 protection and system efficiency ≥ 125 LPW with option for 3000K 10 KV SPD corrosion resistant complete with driver and lampProtection including street light fitting bracket nuts, bolts, washers complete, all as specified and directed. Make:Halonix/Philips/CG/Bajaj 313 Supply and fix in repair bracket for street light fitting made out of40 mm dia light grade GI tubing bent to required shape 1.5m long including necessary GI clamps, nuts bolts and washers and fixing to the pole etc complete all as specified and directed. 314 Supply and fixing in repair Round spherical garden lighting, post top lantern having B22 holder suitable for LED bulb10 watt, 220 volt,50HZ,IP65 including suitable of GI tubing ,length as per site requirement on gate pillars/ garden lights for fixing the lamp, wiring with 1.5 Sqmm PVC insulated strandedcopper conductor includingPCC work for fixing, of light fitting complete all as specified and directed.Make: Philips/ Havells/Bajaj/CG. 315 Suply and fix in repairs LED decorative post top lantern fitting 40W, 230V AC with IP 65 protection and resistant to impact and corrosion with necessary electrical connection completeall as specified as directed. Make: Bajaj / Philips/Halonix/ CG 316 Supply and fix in repair weather proof PVC junction box approved by CPRI for street light control box made out of not less than 2mm thick and size 140x140x100mm (approx) complete with hinged door locking arrangement and consisting of 2 Nos of suitable size cable glands consisting of 01 No. panel mounted connector 4 pole 32 Noincluding connecting up with the electrical connections and fixing with clamps etc complete and all as specified anddirected. 317 Supply and fix 1100 Volts grade heavy duty flat weather proof twin core cable of size 6 Sqmm with multistrand aluminium conductor including taking down of old one complete all as directed and specified. Make: Plaza/Polycab/ Finolex/Havells 318 Supply and fixing LED flood light 100 watt 230 V AC outdoor type including necessary bracket with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp including taking down of old unserviceable fitting of any capacity.Make :Bajaj/Philips/CG/Halonix. 319 Supply and fixing in repair IP65 rated LED Bollard with robust design and efficient light distribution 10 watt on existing pipe of any size and height with all accessories prewired fixed with FI clamps nuts bolts etc., including taking down existing fittings all as specified and directed Make : Crompton/ Halonix/Bajaj/ Philips 320 Suply and fix in repairs LED decorative post top lantern fitting 25 W, 230V AC with IP 65 protection and resistant to impact and corrosion with necessary electrical connection completeall as specified as directed. Make: Bajaj / Philips/Halonix/ CG 321 Supply and fix 1100 Volts grade heavy duty flat weather proof twin core cable of size 10 Sqmm with multistrand aluminium conductor including taking down of old one complete all as directed and specified. Make: Plaza/Polycab/ Finolex/ Havells 322 Material and labour in repair for 3 ½ core 25 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells/ Polycab/ RPG Asian 323 Material and labour in repair formaking straight through joint with suitablejointing kit consisting of water proof adhesivesfor UG cable of size 3.50 core 16 Sqmm to 25 Sqmm, complete all as specified and directed. 324 Servicing/ Periodical maintenance of following capacity DG Set of any make consisting of complete servicing and checking entire system as per manufacturers catalogue including testing complete with replacing of minorconsumables itemslike grease, nut bolts etc during conducting periodic servicing as per the manufacturers recommendation at the time of routine monthly checks. Capacity 20KVA DG Set - Location:-street lights CQAE Area - 01 No Maintenance Schedule of DG Sets :- The contractor shall carried out following activity during ofthe period of contract :- 325 (a)Daily maintenance of DG Sets to be carried out :- 326 (i) Clean the external surface of the DG set. 327 (ii)Check engine oil level. 328 (iii) Check engine coolant level. 329 (iv) Check fuel in the tank. 330 (v)Check all nuts and bolts. 331 (vi) Check tension of fan belts. 332 (vii) Check batteries and battery connections. 333 (viii)Check fuel lines and fuel tank. 334 (b)Weekly maintenance of AMF Panels :- 335 (i) Checking all electrical connections. 336 (ii)Checking all contact points/ Bus bars. 337 (iii) Checking timers (AC/ DC). 338 (iv) Checking all selector switches (voltmeter and Ammeter). 339 (v)Check RPM, Voltage, Amps and Hz. 340 (vi) Checking indicator lamps. 341 (vii) Checking main auxiliary contacts and relays. 342 (viii)Checking contact coils. 343 (ix)Checking, volt/ amps/ energy/ PF/ KWH meters/ CTs. 344 (x) Checking auto/ manual functions. 345 (xi)Check and tight screws and bolts. 346 (xii)Check battery charger output voltage. 347 (xiii) Cleaning the panel. 348 (xiv) Checking all MCCBs and fuses. 349 (xv) Checking alarms and hooter. 350 (c) Monthly maintenance of DG Sets to be carried out :- 351 (i)Check oil bath cleaner oil level. 352 (ii) Check for proper tension in the belts. 353 (iii) Check starting battery electrolyte level and specific gravity. 354 (iv) Check the fuel lines from the tank for leakages. 355 (v) Check the end cover of the alternator and tighten the bolts. 356 (vi) Check physically the exhaust silencer for rigidness. 357 (vii) Check the water hoses for leakages if any. 358 (viii) Drain sediment from fuel filter & fuel tank. 359 (ix) Check dry type air filter element and clean. 360 (x) Check engine alternator coupling and mounting bolts. 361 (xi) Tight all bolts and nuts in alternator terminal box. 362 (xii)Check for any unusual sound during cranking of the engine. 363 (xiii)Check for any fuel/ water leakages. 364 (xiv)Check for any unusual vibrations. 365 (xv)Check proper charging of battery. 366 (xvi)Check exhaust system for any leakages. 367 (xvii) Check for proper circulation of coolant/ cooling of engine. 368 (xviii) Check physically the exhaust silencer for rigidness. 369 (xix) Check throttles linkage. 370 (xx) Checking to electric control panel throttle linkage. 371 (xxi) Supply and greasing to all bearing & movable parts. 372 (d)Quaterly Schedule to be carried out :- 373 (i)Checking of hydraulic governor oil level and toping up level. 374 (ii) Clean the crank case breather. 375 (iii)Check battery charging system & topping up electrolyte and maintenance of specific gravity. 376 (iv) Checking electric connection & generator control panel. 377 (v) Greasing to all bearing and movable parts. 378 Note :- The unitrate quoted is deemed to be inclusive of the followings :- 379 (a)DG Sets are placed at various locations of CQAE (WE). Therefore,the bidders areadvised to visit the location of DG Sets before quoting the tender. 380 (b)Servicing/ repair of DG Set shall be carried out by authorised dealer/ agency of manufacturer as approved by Engineer-in-Charge and where service/ repair is being carried out at site shall be under the expert supervision of authorised service agent. 381 (c) The make of DG sets are Kirloskar/ Greaves Cotton 382 (d)Filling of DHPP (N) in all mentioned DG Sets at various locations will be the responsibility of the contractor. However, DHPP (N) will be issued by MES. The amount for filling of DHPP (N) in DG sets is deemed to be inclusive in unit quoted rate. 383 (e) DHPP (N) required at the time of maintenance/ testing will be issued by MES. 384 (f)Representative of contractor shall maintain & update the maintenance/ breakdown register regularly and same will be checked by Engineer-in-Charge periodically. 385 (g)The monthly check shall be done once in a month but whenever breakdown occurs in DG set, the contractor has to attend all complaint unlimitedly through authorised service agent of the equipment/ machinery. 386 (h)The unit rate is deemed to be included for Cleaning of the surrounding area of DG set 5 mtr from plinth protection ofE/M installations includingremoving of accumulated earthof any width and depth upto 15cm cleaning / Cutting the grass with hand operated petrol/ kerosene driven grass cutting machine andremoving thegrass waste to outside MD land. 387 (j)In case of minor defect, entire Job shall be completed within 06 hrs from the time of registration of complaint, failing which penalty charges @ Rs. 500/- per hours shall be recovered. 388 (k)In case of major defect, the period for attending of complaint shall be decided by the GE/EIC by accessing extent of repair required through joint inspectionby Engineer-in-Charge and authorised service agent of the equipment at the site. If complaint is not rectified within the stipulated period and the GE is not satisfied with the reason for delay, then penalty at the rate of Rs. 600/- per hours shall be deducted from the dues of the contractor. 389 (l)Please note that above penalty is exclusively other than the condition 67 of IAFW - 2249 and shall be treated as interim condition of the contract and shall be enforce above as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt. 390 (m) The decision of the Accepting Officer in this regard shall be final and binding. 391 (n)The contractor shall be responsible to maintain the DG set in serviceable condition for entire contract period. 392 Description all as per Sl Item No 324 here in before but for Capacity 40KVA DG Set- Location:-Pump House-1 No 393 Description all as per Sl Item No 324 here in before but for capacity125 KVA DG set Location:-Tech building :- 1 No 394 Description all as per Sl Item No 324 here in before but for capacity 250 KVA DG set Location:-Tech building :- 1 No 395 Dismantling/ taking down complete radiator assembly of 20 KVA to 40 KVA DG Set and transportation to authorised workshop for following repairs :-(a) Opening the radiator assembly with brazing/ welding for repair/ service.(b)Cleaning of all water tube with diluted solution of HCL and cleaning with water pressure and removing the sludge and dust from inside the tank by flushing out.(c)Determining the leak/ puncher in radiator tubes.(d)Repair of fins by soldering/ brazing.(e)Repair of bottom brass water tank by soldering/ brazing.(f) Repair of radiator hose assembly.(g)Fixing the complete radiator assembly to its original position and testing complete all as specified and directed by Engineer-in-Charge. 396 Dismantling/ taking down complete radiator assembly of 125 KVADG Set and transportation to authorised workshop for following repairs :-(a) Opening the radiator assembly with brazing/ welding for repair/ service.(b)Cleaning of all water tube with diluted solution of HCL and cleaning with water pressure and removing the sludge and dust from inside the tank by flushing out.(c)Determining the leak/ puncher in radiator tubes.(d)Repair of fins by soldering/ brazing.(e)Repair of bottom brass water tank by soldering/ brazing.(f) Repair of radiator hose assembly.(g)Fixing the complete radiator assembly to its original position and testing complete all as specified and directed by Engineer-in-Charge. 397 Taking down old unserviceable self motorof capacity 20 KVA to 40 KVAand carrying to authorised work shop for servicing includingreplacment of unserviceable spare parts Brush, holder, solonoid switch, armature bush, filed coil complete and refixing, testing complete all as specified and directed. 398 Taking down old unserviceable self motorof capacity 125 KVAand carrying to authorised work shop for servicing includingreplacment of unserviceable spare parts Brush, holder, solonoid switch, armature bush, filed coil complete and refixing, Testingcomplete all as specified and directed. 399 Removing and replacing the old unserviceable one with new AVR (Automatic Voltage Regulator) suitable for Kirloskar curve of capacity 20 to 40KVA having input voltage 2 phase + neutral sensing voltage 415 output voltage 95V DC, output current 4A DC voltage regulation +/- 1 % average volts, over excitation current tripping, fuse protection 4A, fast acting and frequency 50 Hzcomplete all as specified and directed. 400 Removing and replacing the old unserviceable AVR (Automatic Voltage Regulator) suitable for capacity 125KVA having input voltage 2 phase + neutral sensing voltage 415 output voltage 95V DC, output current 4A DC voltage regulation +/- 1 % average volts, over excitation current tripping, fuse protection 4A, fast acting and frequency 50 Hzcomplete all as specified and directed. 401 Taking down 12/ 24 volts self starter assembly from DG set and transporting to its authorised workshop for repair/ servicing by replacement of defective spare parts such as carbon brush, carbon ring, bearing, bush, defectine wiring, winding and soldering after repair including testing after repair/ service and re-installation in original position for satisfactory functioncomplete all as specified and directed. 402 Supply and fixingin replacement self starter 12 Volts of DG Sets complete all as specified and directed. 403 Supply and fixingin replacement battery cable assembly (-ve & +ve) complete all as specified and directed.Note :- Items like clamp, lugs, nut, bolts and copper cable of size 25 sqmm upto 1 mtr required for connection is deemed to be inclusive in unit rate quoted. 404 Supply and fixingin replacement maintenance free lead acid sealed battery (SMF) 12 volts 90 AH complete all as specified and as directed.Make : EXIDE. / Amaron/ Amar RajaNote :-Old battery shall be deposited in MES store yard. 405 Supply and fixingin replacement maintenance free lead acid sealed battery (SMF) 12 volts 180 AH complete all as specified and as directed.Make : EXIDE. / Amaron/ Amar RajaNote :-Old battery shall be deposited in MES store yard. 406 Material and labourOpening disconnecting LT Cable connections with care from Auto-Main Failure Panel and checking throughly with Fault Detector Instrument at Site and replacement of Minor Defective Parts as required at Site suitable for 20 KVA to 40 KVA DG Setcomplete all as specified and as directed. 407 Material and labourOpening disconnecting LT Cable connections with care from Auto-Main Failure Panel and checking throughly with Fault Detector Instrument at Site and replacement of Minor Defective Parts as required at Site suitable for 125 KVA DG Setcomplete all as specified and as directed. 408 Supply and fix in replacement of selectorswitch 16 A 2 pole 2 way complete all as specified and as directed. 409 Supply and fix in replacement of selectorswitch 16 A 3 pole 3 way complete all as specified and as directed. 410 Supply and fix in replacement of RPM meter assembly complete set including rubber gasket, wire as per sample complete all as specified and as directed. 411 Supply and fix in replacement of add-on auxilury contactorblock 2No-2NC complete all as specified and as directed. 412 Supply and fix in replacement of electronictimer delay of range12 sec to 120 sec operational in 240V AC supply complete all as specified and directed. Make:- Selectron or equivalent 413 Supply and fixingin replacement of Relay for control contactor AC control std. Coil Voltage - 24, 110, 240, 415V 50HZ (2 NO + 2 NC) complete all as specified and directed. Make L& T / BCH/ ABB 414 Supply and fixing in replacement indicator lamp RYB complete all as specified and as directed. 415 Supply and fix in replacement of push button for Start/Stop switch allas per sample complete all as specified and as directed. 416 Supply and fix in replacement of Relay for single phase preventor 6 wire suitable for all mode operation all as directed. 417 Supply and fix in replacement ofelectronic Oil pressure sensor complete with wiring, connectors, bottle thimble all as directed 418 Supply and fix in replacement of 12V/24V 11 pin PLA relay with base all as specified and as directed. 419 Supply and fix in replacement of radiator hose of any capacity complete all as specified and directed. 420 Supply and fix in replacement of oil drain hose set complete all as specified and as directed. 421 Supply and fix in replacement of fuelhose set nylon type of any capacity complete all as specified and directed. 422 Material and labourfor replacement of door hinges of Acoustic enclosureheavy duty metal type for Left/Right side complete all as specified and directed. 423 Supply and fixingMCCB 200A, 36 KA, 4 Pole, 415V including taking down unserviceable one, complete all as specified and as directed. Make - L &T/Havells/Indoasian 424 Supply andfix in replacement of water pump assembly of water cooling system of DG set any capacity complete all as specified and directed. 425 Supply and fix in replacement of electronic water temp gauge sensor double pin in byepass complete with wiring, connectors, bottle thimble complete all as specified and directed. 426 Supply and fix in replacement of radiatorfan belt suitable for any capacity DG set complete all as specified and as directed. 427 Material and labourfor distilled water in 5 ltr/ 2 ltr capacity sealed cane to be filled in batteries complete all as specified and directed. 428 Material and labourof electrolyte for battarycomplete all as specified and directed. 429 Supply and fixingMCCB 63A, 16 KA, 4 Pole, 415V including taking down unserviceable one, complete all as specified and as directed. Make - L &T/Havells/Indoasian 430 Supply and fixingin replacement stop solenoid assembly 12V/ 24V DC for micro pump (two coil) heavy duty electrical control make energise to stop of DG Setscomplete all as specified and directed.Make :- Kirloskar or existingbrand of defective components or any reputed suitable make as approved by GE 431 Disconnecting the existing battery of capacity 12V 90 to 180 AH from the DG set, taking it to battery workshop, draining out the complete unserviceable electrolyte acid from the battery, filling up with new Electrolyte acid to the required level, charging the battery, testing the battery for correct specific gravity, bringing back to the location, connecting to DG set, start the engine for satisfactory function all as directed by Engineer-in-charge. 432 Supply and fixing in replacement of brass terminal suitable for 12 Volts, 90/180 AHbattery complete all as specified & directed. 433 Supply and fixingBattery charging alternator assembly 12 Volts of DG Sets complete including taking down existing one complete all as specified & directed. 434 Material and labourRepairs to 12V battery charging alternator assembly by removing, dismantling, replacing the unserviceable burnt rotor and stator assembly completly including insulation sleeves and refixing to the engine and testing to the satisfaction of DC volts & Ampsby charging of battery complete all as specified & directed. 435 Supply and fix in replacement of lubrication oil filter element with O ring of Make MICO / Kirloskar / Mahle/ Cummins as required at site for 20KVA capacities of DG Sets complete all as specified and as directed. 436 Supply and fix in replacement of lubrication oil filter element with O ring of Make MICO / Kirloskar / Mahle/ Cummins as required at site for 40KVA capacities of DG Sets complete all as specified and as directed. 437 Supply and fix in replacement of lubrication oil filter element with O ring of Make MICO / Kirloskar / Mahle/ Cummins as required at site for 125KVA capacities of DG Sets complete all as specified and as directed. 438 Supply and fix in replacement of lubrication oil filter element with O ring of Make MICO / Kirloskar / Mahle/ Cummins as required at site for 250 KVA capacities of DG Sets complete all as specified and as directed. 439 Supply and fixingin repairs earth Fault relay complete all as specified and directed. 440 Supply and fix in replacement of turbo cooler rubber hose of any capacity complete all as specified and as directed. 441 Material and labourfor lubrication oil SAE 15 W - 40grade API CI 4 plustype in sealed container for DG set Top up and change the oil in the sump after completely flushing the old oil from the tank/sump and cleaning of the same complete all as specified and as directed. (Make :Castrol/Valvoline/Servo) 442 Supply and fix in replacement of oil seal assembly of any capacity as per sample complete all as specified and directed. 443 Material and labour for 3 ½ core 70 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole complete including taking down unserviceable one all as specified and directed. Make : Havells/Polycab/ RPG Asian 444 Material and labour for 3 ½ core 95 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole complete including taking down unserviceable one all as specified and directed. Make : Havells, Polycab, RPG Asian 445 Material and labour in repair formaking straight through joint with suitablejointing kit consisting of water proof adhesivesfor UG cable of size 3.50 core 70 Sqmm to 95 Sqmm, complete all as specified and directed. 446 Material and labour forBoring of holes under road, pavement hard standings by trenchless technology using ultra sound technique and necessary machine including HDPE pipes upto 100 mm dia suitable for 0.4 Mpa working pressure, complete all as specified and directed. 447 Disconnecting of burnt/ damaged cables from panels/ junction boxes etc, cutting out the burnt out ends, making new end joints by supply and fixing new aluminium lugs/ insulation tape etc and reconnecting using new nuts/ bolts/ washer etc and restoring three phase and neutral in the junction box, complete all as specified and as directed for thecable sizefrom 70 Sqmmto 95 Sqmm 3.5 core of underground LT armoured cables.Note :- Earth work required for extending the incoming/ outgoing cable in junction box/ panel board etc shall deemed to be included in the unit rate quoted. 448 Supply, installation, commissioning and testing of factory assembled, floor mounted, free standing type tested LT Feeder pillar panels, with canopy, as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accordance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS compliant & Halogen free. The manufacturer of boards/panels shall submit a copy oftype test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thremoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be minimum 200mm for air circulation & to minimize temp rise. Panel should be fitted with one No.polycarbonate IP 65, 9 W LED translucent bulk head luminaire color temp not less than 6500K, PF >0.95 under canopy for easy maintenance. Panel should be fitted outside with one No. of 16 A 3 Pole IP65 industrial socket and 01 No. of 32A 5P IP 65 industrial socket. 3 Phase and neutral 400 Amp current carrying capacity of Aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20 mm graded crushed stone aggregate for bedding upto a height of 45 CM above ground level, including dismanting and taking out U/s LT panel board and reconnecting existing LT UG Cable with new panel board all as directed :- 449 (a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 250 Amp, 36 KA- 01 No (Incomer). (b) MCCB with thermal magnetic release 4 Pole, 415 V of capacity100 Amp,16 KA- 02 Nos.(c) MCCB with thermal magnetic release 4 Pole, 415 V of capacity63 Amp,16 KA- 02 Nos.(d) Multifunction Meter (V,I,PF) with suitable capacity of CTs- 01 No(e) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set.(f) Space for spare feeder - 01 No. Note :-(i) The Contractor shall submit the drawing for approval of GE before executing the work.(ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S.(iv) MCCB should be ICu =100% ICs.(v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS). 450 Supply, installation, commissioning and testing of factory assembled, floor mounted, free standing type tested LT Feeder pillar panels, with canopy, as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accordance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS compliant & Halogen free. The manufacturer of boards/panels shall submit a copy oftype test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thremoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be minimum 200mm for air circulation & to minimize temp rise. Panel should be fitted with one No.polycarbonate IP 65, 9 W LED translucent bulk head luminaire color temp not less than 6500K, PF >0.95 under canopy for easy maintenance. Panel should be fitted outside with one No. of 16 A 3 Pole IP65 industrial socket and 01 No. of 32A 5P IP 65 industrial socket. 3 Phase and neutral 400 Amp current carrying capacity of Aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20 mm graded crushed stone aggregate for bedding upto a height of 45 CM above ground level, including dismanting and taking out U/s LT panel board and reconnecting existing LT UG Cable with new panel board all as directed :- 451 (a) MCCB with thermal magnetic release 4 Pole ,415 V of capacity 250 Amps ,36 KA- 01 No (Incomer).(b) MCCB with thermal magnetic release 4 Pole ,415 V of capacity 63 Amps ,10 KA- 04 Nos.(c ) Multifunction Meter (V,I,PF) with suitable capacity of CTs- 01 No.(d) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set.(e) Space for spare feeder -01 No.Note :-(i) The Contractor shall submit the drawing for approval of GE before executing the work.(ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S.(iv) MCCB should be ICu =100% ICs.(v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS). 452 Material and labourreplacement of existing unserviceable door lock arrangement to DG set canopywith new door lock & key etc as per existing size & type complete all as specified & directed. 453 Supply and fix in replacement of electronic water temp gauge sensor single pin for engine block complete with wiring, connectors, bottle thimble complete all as specified and directed. 454 Supply and fixing in repairs door glass and beading for DG Set of any capacity complete all as specified and directed. 455 Supply and fixing in repairs 24V DC solenoid switch complete all as specified and directed. 456 Material and labourfor Urea which contain 32.5% urea and 67.5 % deionized water complete all as directed . 457 Supply and providing coolant concentrate in sealed container for top up complete all as specified and directed.Make : Valvoline/ Fleet guard/ Mahle 458 Supply and fix in replacement of electronic Fuel Level sensor complete with wiring, connectors, bottle thimble complete all as specified and directed. 459 Supply and fix in replacement of radiator mounting pad set of any size complete all as specified and directed. 460 Supply and Fix in replacement of temeprature guage of any capacity complete all as specified and as directed. 461 Supplyand Replacement of fuel filter element with O ring of Make MICO / Kirloskar / Mahle/ Ashok Leyland/ Cummins as required at site for 20 KVA capacities of DG Setsall as directed by Engineer-in-Charge. 462 Supplyand Replacement of fuel filter element with O ring of Make MICO / Kirloskar / Mahle/ Ashok Leyland/ Cummins as required at site for 40 KVA capacities of DG Setsall as directed by Engineer-in-Charge. 463 Supplyand Replacement of fuel filter element with O ring of Make MICO / Kirloskar / Mahle/ Ashok Leyland/ Cummins as required at site for 125 KVA capacities of DG Setsall as directed by Engineer-in-Charge. 464 Supplyand Replacement of fuel filter element with O ring of Make MICO / Kirloskar / Mahle/ Ashok Leyland/ Cummins as required at site for 250 KVA capacities of DG Setsall as directed by Engineer-in-Charge. 465 Supply and fixing in repairs mechanical type diesel float switch assembly complete all as specified and directed. 466 Supply and fixingin replacement Cooling Fansuitable for DG Set 125 KVA capacity, complete all as specified and as directed. 467 Supply and fixingin replacement Cooling Fansuitable for DG Set 20 to 40 KVA capacity, complete all as specified and as directed. 468 Supply and fix in replacement of flush type LED Digital multi functional meter withparameter (V,I,PF) suitable for DG set AMF panelcompleteof Model A class 1 complete all as specified & directed. 469 Supply and fixingin replacementcontactor 4 pole,with 1 NO + 1 NC aux contacts and coil voltage 240 V/415 volt suitable for AMF Panels of 125 KVADG Set complete all as specified and as directed. MAKE : L&T/BCH/Schneider 470 Supply and fixingin replacementcontactor 4 pole,with 1 NO + 1 NC aux contacts and coil voltage 240 V/415 volt suitable for AMF Panels of 40 KVADG Set complete all as specified and as directed. MAKE : L&T/BCH/Schneider 471 Supply and fixingin replacementcontactor 4 pole,with 1 NO + 1 NC aux contacts and coil voltage 240 V/415 volt suitable for AMF Panels of 20 KVADG Set complete all as specified and as directed. MAKE : L&T/BCH/Schneider 472 Disconnecting the electrical connection from AMF Panel, taking down DG set of cap 20 to 40KVA for major overhauling of engine and transportationto authorised workshop forreplacement of piston assembly complete-4 sets, exhaust valve, cyilinder liner, inlet and out let valves, sealing cap, copper washers,thermostat elements, spin of filter for lubrication oil, oil seal, valve tappet, gasket for cylinder head, bush for injector, gasket for exhuast manifold,joint for bearing housing, joint for delivery volute, turbo repair kit complete all as specified & directed. 473 Supply and fixing in repairs electronic type diesel float switch assembly complete all as specified and directed. 474 Supply and fix in replacment of valve door packing of any capacity complete all as specified and directed. 475 Supply and fix in replacement of Auto source transfer controller unitsuitable for DG set AMF panel of any capacity and as per existing Make complete all as specified and directed. 476 Supply and fixingin repairs change over switch 125 Amps capacity 4 pole 3 phase with enclosure complete all as specified and directed. Make-Legrand/ L&T / Indoasian 477 Supply and fixingin replacement microprocessor based AMF controller unit for AMF Panel flush mounting type suitable for DG Set 20 to 40 KVA capacity as per existing make complete all as specified and directed. 478 Supply and fixingin replacement microprocessor based AMF controller unit for AMF Panel flush mounting type suitable for DG Set 125 KVA capacity as per existing make complete all as specified and directed. 479 Supply and fix in replacement of Air filter elementinner and outer as required at site with O ring of Make MICO / Kirloskar / Mahle/ Cummins as required at site for 20 KVA capacities of DG Sets complete all as specified & directed. 480 Supply and fix in replacement of Air filter elementinner and outer as required at site with O ring of Make MICO / Kirloskar / Mahle/ Cummins as required at site for 40 KVA capacities of DG Sets complete all as specified & directed. 481 Supply and fix in replacement of Air filter elementinner and outer as required at site with O ring of Make MICO / Kirloskar / Mahle/ Cummins as required at site for 125 KVA capacities of DG Sets complete all as specified & directed. 482 Supply and fix in replacement of Air filter elementinner and outer as required at site with O ring of Make MICO / Kirloskar / Mahle/ Cummins as required at site for 250 KVA capacities of DG Sets complete all as specified & directed. 483 Supply and fixingin repairs change over switch 63 Amps capacity 4 pole 3 phase with enclosure complete all as specified and directed. Make-Legrand/ L&T / Indoasian 484 Supply and fixingin replacement ofwiring of AMF panel of capacity DG set including copper wire ,PVCwire holder and other connected items suitable for DG Set 20 to 40 KVA capacity as per existing make complete all as specified and directed. 485 Supply and fixingin replacement of Fly wheel ringincluding nuts and bolt suitable for DG Set 20 to 40 KVA capacity as per existing make complete all as specified and directed. 486 Supply and fixingin replacement of Fly wheel ringincluding nuts and bolt suitable for DG Set125 KVA capacity as per existing make complete all as specified and directed. 487 Surface dressing in hard / dense soilnot exceeding 15 cm deepand clearing all the grass weeds etc in the sub station yards after removing stone aggregate asideall as directed at site including setting / spreading back the aggregate complete all as specified and directed at site.Note:- (i)Additional stone aggregate required shall be measured and paid separately under relevant items of this schedule.(ii)The rate also deemed to be included for labour (iii) The sub station yards shall be kept cleanthrough out the contract period by removing the grass/weeds as many as times required depending on the growth of the grass. (iv)The rates shall be deemed to includesthe cost of removing two time the grass,weeds,debris,excess soil etc to a distance not less than 50 M and keeping the excavated surface clean and levelled all as directed. 488 Supply and laying of GI pipe light grade for cable protection of size 80 mm bore complete with fitting completeincluding taking down unserviceable one all as inspecified and directed. 489 Material and labour for 3 ½ core 185 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheather laying in trenches/cable ducts, fixed to wall/pole complete including taking down unserviceable one all as specified and directed. Make : Havells/ Polycab/ RPG Asian 490 Disconnecting of burnt/ damaged cables from panels/ junction boxes etc, cutting out the burnt out ends, making new end joints by supply and fixing new aluminium lugs/ insulation tape etc and reconnecting using new nuts/ bolts/ washer etc and restoring three phase and neutral in the junction box, complete all as specified and as directed for thecable sizefrom 150 Sqmmto 185 Sqmm 3.5 core of underground LT armoured cables.Note :- Earth work required for extending the incoming/ outgoing cable in junction box/ panel board etc shall deemed to be included in the unit rate quoted. 491 Supply, installation,commissioning and testing of factory assembled ,floor mounted ,free standing type tested LT Feeder pillar panels,with canopy ,as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycrabonate,should be weather vermin proof, anti -acid,anti-corrossive,UV resistance in accordance with IEC 61439-1,fire retardant and self extingushing in accordance with IEC 60695-2-11 ,UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accordance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties ,RoHS compliants & Halogen free. The manufacturer of boards/panels shall submit a copy oftype test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tight to base with thermoplastic screw having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosuser should be above 200mm for air circulation & to minimize temp rise. Panel shallbe fitted with one No. ofpolycarbonate IP 65 9 W LED transperent bulk head luminaire 6500K,PF >0.95 under canopy for easy maintenance . Panel should be fitted outside with one No. of 16 Amp 3 Pole IP65 industrial socket and 01 No. of 32 Amp 5P IP 65 industrial socket. 3 Phase and neutral 300 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20mm graded stone aggregate for bedding upto a height of 45 CM above ground level ,including dismanting and taking out old U/s LT panel board and reconnecting existing LT UG Cable with new panel board, complete all as specified and directed :- 492 (a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 200 Amp, 36 KA- 01 No (Incomer).(b) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 100 Amp, 10 KA- 01 No.(c) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 63 Amp, 25 KA- 01 No.(d) Multifunction Meter (V,I,PF) with suitable capacity of CTs- 01 No.(e) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set.(f) Space for spare feeder - 01 No. Note :-(i) The Contractor shall submit the drawing for approval of GE before executing the work.(ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S.(iv) MCCB should be ICu =100% ICs.(v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS). 493 Supply, installation,commissioning and testing of factory assembled ,floor mounted ,free standing type tested LT Feeder pillar panels,with canopy ,as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycrabonate,should be weather vermin proof, anti -acid,anti-corrossive,UV resistance in accordance with IEC 61439-1,fire retardant and self extingushing in accordance with IEC 60695-2-11 ,UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accordance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties ,RoHS compliants & Halogen free. The manufacturer of boards/panels shall submit a copy oftype test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tight to base with thermoplastic screw having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosuser should be above 200mm for air circulation & to minimize temp rise. Panel shallbe fitted with one No. ofpolycarbonate IP 65 9 W LED transperent bulk head luminaire 6500K,PF >0.95 under canopy for easy maintenance . Panel should be fitted outside with one No. of 16 Amp 3 Pole IP65 industrial socket and 01 No. of 32 Amp 5P IP 65 industrial socket. 3 Phase and neutral 600 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20mm graded stone aggregate for bedding upto a height of 45 CM above ground level ,including dismanting and taking out old U/s LT panel board and reconnecting existing LT UG Cable with new panel board, complete all as specified and directed :- 494 (a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 400 Amps, 36 KA- 01 No (Incomer).(b) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 200 Amps, 25 KA- 03 Nos.(c) MCCB with thermal magnetic release 4 Pole ,415 V of capacity 100 Amps, 10 KA- 02 Nos.(d) Multifunction Meter (V,I,PF) with suitable capacity of CTs- 01 No.(e) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set.(f) Space for spare feeder - 01 No. Note :-(i) The Contractor shall submit the drawing for approval of GE before executing the work.(ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S.(iv) MCCB should be ICu =100% ICs.(v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS). 495 Material andlabour forTesting of earth resistancevalue from earthing pit test terminal pointand write in/ on existingidentification board complete all as specified and as directed.Around upto 1.50 Metre Area of existing Earth Pit with tightening of Strip comprising of the following process :- 496 The following items are deemed to be inclusive of quoted rate :-(i)The above job shall be carried out by a trained technician having ITI in electrical and well known regarding earthing test. Documantary proof of the education of tradesman shall be produced by the contractor to the Engr-in-charge, before commencement of work. 497 (ii)The aforsesaid test shall be carried out in presence of user and MES represnetative. 498 (iii) Two Party (consisting 2 x 1 No. Technician with 1 No. Helper) shallreport every Morningat 9 AM to JE E/M for Daily earth testing. 499 (iv) Earth Resistance Tester will be provided by the Contractor. (Tester should be caliberated from Authorised Company/ Lab). 500 (v) Contractor shall be responsible for pouring of water in the Earth Pits Weekly at their own arrangement with Water Tanker, etc. (water will be provided by the contractor at his own arrangement and nothing extra will be admissible). 501 (vi) Contractor shall be responsible for marking of Earth check date and due date on existing Plate with synthetic enamel paint as specified by Engineer-in-Charge. 502 (vii)Contractor shall be responsible for cleaning of bushes and grass all around upto 1.50 Metre Area of existing Earth Pit with tightening of Strip. 503 Supply only charcoal dust/Breeze in trenches to improve the ER value of existing earth pits, complete all as specified and as directed. 504 Supply only common salt commercial in trenches to improve the ER value of existing earth pits, complete all as specified and as directed. 505 Material and labour for magnesium sulphate (MgSO4) for improvement of earthing resistivity, complete all as specified and directed. 506 Material and labour for Powder Earthing Backfill Compound, Grade Standard for improvement of earthing resistivity and to increase the absorption of moisture around the earthing electrode, complete all as specified and directed. 507 Supply and fixing in repair 20 mm bore galvanised steel water tubing medium grade with all fitting fixed to wall and ceiling or laid in floors etc, complete all as specified and directed. 508 Supply and fixing in repair 40 mm bore galvanised steel water tubing medium grade with all fitting laid in trenches/or laid in floor etc, complete all as specified and directed . 509 Supply and Fix in repairs Bib Tap of 15 mm dia standard of PTMT any colour high pressure screwed for iron pipe(Minimum weight 90 gms ), complete all as specifed and directed. 510 Taking downn unsv funnel of any type and size Supply and fixing in repair GI funnels for earthing, complete all as specified and as directed. 511 Taking down existing GI earthstrip 25x3mm thick as earthing lead with its accessories and re fixing to wall/roofs etc. drawn in conduit/GI pipe etccomplete all as specified and as directed.Note:- Unit rate is deemed to be included for old broken insulators/ clamps to replace with new insulators of existing size as per site and making good disturbed surfaces of floors/walls/ceiling etc complete all as directed. 512 Supply and fixing in replacement of aluminium strip 25x3mm fixed with epoxy based insulator for down conductor air terminal network including drilling two Nos holes at each joint, one set of lead washers between strips, two sets GI nut andbolt, gutties, screws etc,.on wall /roof including necessary fixing arrangement up to height 20mtrcomplete all as specified and directed.Note:- Unit rate is deemed to be included for old broken insulators/ clamps to replace with new insulators of existing size as per site and making good disturbed surfaces of floors/walls/ceiling etc complete all as directed.(ii) All safety measures shall be the responsibility of the contractor 513 Taking down of serviceable aluminium strip 25x3mm and refixing the same with epoxy based insulator/post insulator/spacerfor down/ lightening conductor air terminal network including drilling two Nos holes at each joint, one set of lead washers between strips, two sets GI nut andbolt, gutties, screws etc.on wall /roof including necessary fixing arrangement up to height 20mtrcomplete all as specified and directed.Note:- Unit rate is deemed to be included for old broken insulators/ clamps to replace with new insulators of existing size as per site and making good disturbed surfaces of floors/walls/ceiling etc complete all as directed.(ii) All safety measures shall be the responsibility of the contractor 514 Supply and fixing in repair test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos. 8mm dia 25mm long hexagonal. head screw, complete all as specified and directed. 515 Material and labourin repairs Galvanised iron Earth strip of size 32 x 6 mm fixed on proper post insulator at the instrument end complete all as per specified and as directed. 516 Repairing and maintenance of old existing earth pit by taking out carefully earth plate, watering pipe, earth lead protection pipe and re-buried the same after removing sludge from the plate & pipes including re-connection/brazing the plate and strip, wherever is required at site (Earth pit not less than 2.25 mtr deep below normal ground level ) with top edge of earth plate not less than 1.5 metres below normal ground level,complete all as specified and directed includingPCC 1:3:6 type C1 using 20mm graded stone aggregate for pit with cover of RCC 1:2:4 type B1 using 20mm graded aggregate, reinforced with welded steel wire fabric not less than 4 kg per Sqmtr with handle and angle iron frame,watering arrangment with 20 mm bore GI medium grade pipe ISI marked, GI funnel with GI mesh,filling with mixture of common salt and charcoal,necessary excavation, refilling, removing away soil and earth work in any type of soil including test point, testing and commissioning, complete all as specifed and as directed.Note : GI Funnel, brazing, mixture of salt/char coal/MgSO4 shall be measured and paid separately under releavant items. 517 S&F in repair copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc including taking down existing old unserviceable copper strip etc, complete all as specified anddirected. Note : - All Joints should be joined by Exothermic Welding or Brazing. 518 Material and labour for Brazing of copper/Aluminium for continuity, complete all as specified and as directed. 519 Supply and fix in repair of wall mounted fans PVC body 230 Voltssingle phase oscillating 400mm sweep suitable for wall mounting all as specified and directed. Make : Havells/Bajaj/ Orient.Note:-(a)Old Unserviceable ceiling fan shall be deposited to MES store yard. 520 Material and labour for fixing earth indicators made out of 3 mm thick MS sheet of size 200mm x 300mm duly fixed in MS angle iron 25mmx25mmx3mm of 450 mm long to be fixed to ground by means withnecessarycement concrete andpainting with two coats of synthetic enamel paint over a coat of red oxide primer, writing earth reading and connected items like painting of panel etc, and necessary excavation and earth work including taking down old, complete all as specified and as directed. 521 Supply, installation, testing & commissioning of maintenance free chemicalearthing system comprising of 17mm dia copper bondedrod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducingliquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 A by any NABL accredited lab. The above mentioned rod shall be installed in 4-6 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation including taking down existing one, complete all as specified and directed..Make : Model HTSP 317 of safeTrode or equivalent in Snaga/ Cubes 6 Global 522 The quoted rate shall also deemed to be included the following :- (i)Prior toinstallation of maintenance free chemicalearthing, soil resistivity test to be carried out at the location where earthingwork to be donein presence of Engr-in- Charge/JE (E/M),user and the report has tosubmitto Garrison Engineer with recommendation of manufacturer, if required additional interconnection ofearthing (not more than 08 number of earthing) to achive earth result less then 1 Ohms. The arrangement done for soil resistivity testingandsubmission of report with recommendationdeemed to be included in the quoted rate. 523 (ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors. 524 (iii) Rateofearth energizer compound of 25 Kg of 02 bags and earthresistance reducingliquid 10 litre per cane for each pit deemed to be included in the quoted rate. 525 (iv)Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor along with the sample approval 526 (v) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH value should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete. 527 (vi) Copper strip of size 20 x 3 mm shallbe fixed on proper post insulator at the instrument end (copper strip upto 7.5 RM shall be considered in unit quoted rate and extra will be measured and paid separately). 528 (vii)Testing of earth shall be carriedout in presence ofdepartmental and user representativeand report shall be submitted to Garrison Engineer duly signed by all concerned. 529 (viii)Earth resistance tester will be provided by the contractor.Tester should be calibrated from authorised company/ lab. 530 (ix)Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintained duly signed by all concerned.After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained. 531 (x) The contractor shall give a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion. 532 (xi) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including soft/ disintegrated or hard rock. 533 (xii) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is maintained. 534 (xiii) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing for each earthing shall be retained from payment due to the contractor from final bill for the guarantee period. 535 (xiv) The electrode shallcarry manufacturers name . 536 (xv) The connection clamp shall be permanentlly welded to the copper boundedrodto avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination. 537 (xvi) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm. 538 (xvii)Earth work such as auguring andmaking good the surrounding area shall carried out in any type of soil. 539 (xviii)The contractor shall submit CPRI India certified document for copper bounded rod to ensure genuineness of material. 540 (xix) Sign boardof mild steel sheet 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxideZinc chrome primer showing result of earthing shall be fixed near the earth pit after completion as directed by engr -in- charge. 541 Material and labour for Earth pit cover madeof heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 7.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mm for each electrode pit complete including taking down old one complete all as specified and directed.Make : Model SEPC 250 of SAFE TRODE or equivalent in Snaga/ Cubes 6 Global 542 Supply, installation, commissioning and testing of factory assembled, floor mounted, free standing type tested LT Feeder pillar panel, with canopy, as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accordance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS compliants & Halogen free. The manufacturer of boards/panels shall submit a copy oftype test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be minimum 200mm for air circulation & to minimize temp rise. Panel should be fitted with one No.polycarbonate IP 65, 9 W LED translucent bulk head luminaire color lamp not less than 6500K, PF >0.95 under canopy for easy maintenance. Panel shall be fitted outside with one No of 16 Amp 3 Pole IP65 industrial socket and 01 No. of 32Amp 5P IP 65 industrial socket. 3 Phase and neutral 630 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20mm graded aggregate forbedding upto a height of 45 CM above ground level, including dismanting and taking out old U/s LT panel board and reconnecting existing LT UG Cable with new panel board amplete all as specified and all as directed and comprising of the following:- 543 (a) ON load change over switch 4 Pole, 415 V of capacity 400 Amp, 36 KA - 01 No . (b) MCCB with thermal magnetic release 4 Pole, 415 V of capacity400 Amp,36 KA- 02 Nos.(c) Multifunction Meter (V,I,PF) with suitable capacity of CTs- 01 No(d) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set. (e) Space for spare feeder - 01 No. Note :-(i) The Contractor shall submit the drawing for approval of GE before executing the work.(ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S.(vi) MCCB should be ICu =100% ICs.(v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS). 544 Supply, installation, commissioning and testing of factory assembled, floor mounted, free standing type tested LT Feeder pillar panels, with canopy, as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accordance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS compliant & Halogen free. The manufacturer of boards/panels shall submit a copy oftype test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thremoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be minimum 200mm for air circulation & to minimize temp rise. Panel should be fitted with one No.polycarbonate IP 65, 9 W LED translucent bulk head luminaire color temp not less than 6500K, PF >0.95 under canopy for easy maintenance. Panel should be fitted outside with one No. of 16 A 3 Pole IP65 industrial socket and 01 No. of 32A 5P IP 65 industrial socket. 3 Phase and neutral 600 Amp current carrying capacity of Aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20 mm graded crushed stone aggregate for bedding upto a height of 45 CM above ground level, including dismanting and taking out U/s LT panel board and reconnecting existing LT UG Cable with new panel board all as directed :- 545 (a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 400 Amps36 KA- 01 No.(Incomer).(b) Change over switch 400A, 4P front operated - 01 No.(c) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 160 Amps25 KA- 02 Nos (O/G).(d) MCCB with thermal magnetic release 4 Pole, 415 V of capacity125 Amps 25 KA- 02 Nos (O/G).(e) MCCB with thermal magnetic release 4 Pole, 415 V of capacity100 Amps 10 KA- 01 No (O/G)(f) MCCB with thermal magnetic release 4 Pole, 415 V of capacity63 Amps 10 KA- 01 No (O/G)(g) MCB SPNof 240 V of capacity 40 Amps 10 KA- 01 No.(h) Multifunction Meter (V,I,PF) with suitable capacity of CTs- 01 No.(j) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set.(k) Space for spare feeder - 01 No. Note :-(i) The Contractor shall submit the drawing for approval of GE before executing the work.(ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S.(iv) MCCB should be ICu =100% ICs.(v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS). 546 Note :- An amount of Rs 2,49,138.00 on account of credit schedule for schedule A part II shall be deducted from the total amount of BOQ to arrive at the contract sum.
Contract Date : 16 Oct, 2025   |   Contract Value : 1.43 Crore
BRR : 214091 Maintenance Of Electronic Installation & Fans, Repair Maintenance Of A / C Equipment, Pump Set At Bungalow Of Senior Officers & Ministers Residences, Tilak Marg, Rouse Avenue, Darya Ganj, Chanakya Puri & Nearby Areas New Delhi ( Sh:- Miscellaneous Electrical Works ) .- Item Description 1 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required ( A ) Group B 2 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. ( A ) Group B 3 Supplying And Fixing Of Following Sizes Of Pvc Conduit Along With Accessories In Surface / Recess Including Painting In Case Of Surface Conduit, Or Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. ( A ) 20 Mm 4 ( B ) 25 Mm 5 Supplying And Fixing Of Following Sizes Of Steel Conduit Along With Accessories In Surface / Recess Including Painting In Case Of Surface Conduit, Or Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required ( A ) 20 Mm 6 ( B ) 25 Mm 7 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required ( A ) 3 X 1.5 Sq. Mm 8 ( B ) 6 X 1.5 Sq. Mm 9 ( C ) 3 X 4 Sq. Mm 10 ( D ) 6 X 4 Sq. Mm 11 ( E ) 3 X 6 Sq. Mm 12 Supplying And Fixing Following Modular Base & Cover Plate On Existing Modular Metal Boxes Etc. As Required. ( A ) 1 Or 2 Module 13 ( B ) 3 Module 14 ( C ) 6 Module 15 ( D ) 8 Module 16 ( E ) 12 Module 17 Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. ( A ) 5 / 6 A Switch 18 ( B ) 3 Pin 5 / 6 A Socket Outlet 19 ( C ) Telephone Socket Outlet 20 ( D ) Tv Antenna Socket Outlet 21 ( E ) 15 / 16 A Switch 22 ( F ) 6 Pin 15 / 16 A Socket Outlet 23 Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 24 Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate & Switch Box Excluding Modular Plate As Required. 25 Supplying And Drawing Of Utp 4 Pair Cat 6 Lan Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. ( A ) 1 Run Of Cable 26 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) ( A ) 8 Way, Double Door 27 ( B ) 12 Way, Double Door 28 Supplying And Fixing Following Way, Horizontal Type Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) ( A ) 6 Way ( 4 + 18 ) , Double Door 29 ( B ) 8 Way ( 4 + 24 ) , Double Door 30 Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, “C” Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. ( A ) Single Pole 31 ( B ) Single Pole And Neutral 32 Supplying And Fixing Following Rating, Four Pole, 415 V, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. ( A ) 40 A 33 ( B ) 63 A 34 ( C ) 100 A 35 Supplying And Fixing 20 A, 240 V, Spn Industrial Type Socket Outlet, With 2 Pole And Earth, Metal Enclosed Plug Top Alongwith 20 A, “C” Curve, Sp, Mcb, In Sheet Steel Enclosure, On Surface Or In Recess, With Chained Metal Cover For The Socket Out Let And Complete With Connections, Testing And Commissioning Etc. As Required. 36 Earthing With G.I. Earth Pipe 4.5 Meter Long, 40 Mm Dia Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. With Charcoal / Coke And Salt As Required. 37 Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Meter Long Etc. With Charcoal / Coke And Salt As Required. 38 Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing As Required. 39 Supplying And Fixing Fancy / Decorative Following Modular Base & Cover Plate On Existing Modular Metal Boxes Etc. As Required. ( A ) 1 Or 2 Module 40 ( B ) 3 Module 41 ( C ) 6 Module 42 ( D ) 8 Module 43 ( E ) 12 Module 44 Supplying And Fixing Following Modular Fancy / Decorative Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. ( A ) 5 / 6 Amps Switch 45 ( B ) 3 Pin 5 / 6 Amp Socket Outlet 46 ( C ) Telephone Socket Outlet 47 ( D ) Tv Antenna Socket Outlet 48 ( E ) 15 / 16 Amp. Switch 49 ( F ) 6 Pin 15 / 16 A Socket Outlet 50 ( G ) Step Type Regulator 51 ( H ) Blanking Plate 52 ( I ) Rj-45 Modular Type Computer Sockets 53 Supplying, Laying And Fixing Of Following Size Dlp U-Pvc Trunking System For Cable Management System I / C Separation Portion For Trunking, Plastic Clip On Partition, Body Joints For Aligning Bases During Installation, End Caps And All Other Accessories Necessary For Installationsin Surface / Recess I / C Connections Etc. As Reqd. ( A ) 80 Mm X 50 Mm Height 54 Supplying, Laying And Fixing Of Following Size Dlp U-Pvc Trunking Systemfor Cable Management System I / C Separation Portion For Trunking, Plastic Clip On Partition, Body Joints For Aligning Bases During Installation, End Caps And All Other Accessories Necessary For Installationsin Surface / Recess I / C Connections Etc. As Reqd. ( A ) 100 To 105 Mm X 50 Mm Height 55 Supplying, Installation, Testing & Commissioning Of Recess Type Upto 12 Watt Led Tunable Downlighter ( 2700-5700 K ) With Smart Led Module Having Facility Of Dimming & Switch On & Off Through App With Reflector Based Fixed Optics Powder Coated Aluminium Cast Housing & Driver In Abs Housing With Matt White Finish & Radiator Heat Sink Body Having High Efficiency Optical System With Reflectors & High Transmittance Lens, Including Connection With 3 X 1.5 Sq.Mm. Pvc Insulated Frls Pvc Sheathed Copper Conductor Etc. As Reqd. 56 Supplying, Installation, Testing & Commissioning Of 8 Watt Per Mtr Flexi Strip Lights Having Color Temperature 2200 K-6000K In Single Strip With 16 Million Color Change Facility And 120 Led / Mtr- Cw 740 Lumen / Mtrs With Integrated Power Supply & Controller Having Facility To Connect With Mobile Based Application Complete With Pasting In Cove Etc. As Reqd. 57 Supplying, Installation, Testing & Commissioning Of 5 Watt Per Mtr Flexi Strip Lights Having Color Temperature 3000 K-6000K With Controller Driver With Pasting In Cove Etc As Reqd. 58 Supplying, Installation, Testing & Commissioning Of 3 To 5 Watt Led Worm White Spot / Spike Light Embeded To Earth With Ip 67 Protectioni / C Making Suitable Mounting / Installation Arrangements Etc. A Reqd. 59 Supplying, Installation, Testing & Commissioning Of 3 To 5 Watt Led Warm White Step Led Light Embeded To Earth With Ip 67 Protectioni / C Making Suitable Mounting / Installation Arrangements Etc. A Reqd. 60 Supplying, Installation, Testing & Commissioning Of Decorative Brass Antique Picture Light 10 Watt Led Directly On Ceiling I / C Connection With 1.5 Sq.Mm Fr Pvc Insulated Copper Conductor Single Corecable And Earthing Etc As Required. 61 Supplying, Installation, Testing & Commissioning Of Round Fancy & Decorative Ceiling Light With Golden Color Diffuser Color With 01 Nos Of Led Lamp I / C Connection With 1.5 Sq.Mm Fr Pvc Insulated Copper Conductor Single Corecable And Earthing Etc As Required. 62 Supplying, Installation, Testing & Commissioning Of Led Post Top Fitting Of System Wattage 25 Watt Post-Top, Energy Saving, Environmental Friendly, Long Life Aesthetically Designed With Symmetrical Light Distribution, Spun Aluminium Landscape Luminaire With High Power Leds As Light Source. I / C Connection, Testing Etc. Complete As Reqd. 63 Supplying, Installation, Testing & Commissioning Of Led Bollard Fitting Of System Wattage 10 Watt Of Multiple Led With Lens Optics And Ip65 Pressure Die-Cast Aluminium Housing For Effective Thermal Management. Total System Lumen Of 10 W, Cct-6500K, Power Factor>0.90, Cri>70, 670Mm Height, Suitable For Working On 240V, 50Hz, Single Phase Ac Supply Complete With Making Suitable Foundation Including Connections Etc. As Reqd. 64 Supplying, Installation, Testing & Commissioning Of Energy Efficient Led Flood Light Luminaries Of System Wattages 120 Watt Complete With Mounting Brackets And Accessories On The Street Light Pole With Help Of Tower Wagon Including Connections Complete As Required. The Led Luminaries Should Confirm The Following Technical Specifications:-A ) Type Of Led: High Power Leds Nichia / Osram / Cree / Philipsb ) Driver Efficiency >85%C ) System Efficacy >110Lm / Wd ) Color Index ( Cri ) Ra>70E ) Color Temperature ( Cct ) Cool White: 4000°Kf ) Input Voltage. 140-270V Acg ) Frequency Range 50-60Hzh ) Power Factor ( Pf ) > 0.95I ) Surge Protection = 10Kvj ) Total Harmonic Distortion ( Thd ) < 10%K ) Working Environment 0°C To 50°C;10%-90%Rh L ) Working Lifetime: >50000 Hrs.M ) Ip Rating :- Ip66n ) Housing And Finish:-Epoxy Powder Coated Die Cast Aluminum Housing With Elegantly Designed Heat Sink For Efficient Thermal Management And To Excellent Corrosion Resistant, Cable Gland P49 Is Provided At Cable Entry Cover & High Quality Toughned Glass. 65 Supplying, Installation, Testing & Commissioning Of Innovative Desktop Led Lumanaire With Direct Light Components For Individual Work Station Illumination And Indirect Light Component For General Room Lighting Madeup Of Triple Glare Control System, ( Tgcs ) For Glare-Reduced, Symmetric Distribution Indirect Component With Limited Beam Angle With Clear, Highly Sratch-Resistance Acrylic Glass Cover With Following Technical Specifications:-Ip:- Ip20luminous Efficient:-99 Lm / Watt, 107 Lm / Watt, 103 Lm / Wattconnected Load:- 56W / 52W / 54Wlife :- 5000Hrscolor Tolerance:- 3 Sdcmcolor Temp:- 2700 K, 6000K, 4350Ksuitable To Operate On Single Phase 240 Volts 50 Hz Ac Supply I / C Connection Complete Etc As Reqd. 66 Supplying, Installation, Testing & Commissioning Of Decorative Suspended Led Luminaire, With Ring-Shaped Light Element. With Indirect Light Intensity Distribution. For Suspended Mounting As Single Luminaire. Suspension Length Consists Of 2000 Mm. The Suspension Length Can Be Individually Set At The Mounting Location. With Indirect Light Intensity Distribution, Shielding Via Primary Shield. Glare Evaluation ( En 12464-1 ) According To Ugr < 22. Luminaire Luminous Flux 1800 Lm, Luminaire Efficiency 17 W, Luminous Efficiency Of Luminaire 106 Lm / W. Light Colour Neutral White, Correlated Colour Temperature ( Cct ) 4000 K, General Colour Rendering Index ( Cri ) R A > 80. Mean Rated Service Life L 80 ( T Q 25 °C ) = 70, 000 H, Mean Rated Service Life L 85 ( T Q 25 °C ) = 50, 000 H. Luminaire Body Of Sheet Steel, Powder-Coated White. Luminaire Diameter Ø 403 Mm, Luminaire Height 50 Mm. Permissible Ambient Temperature ( At ) : -20 °C - +25 °C. Safety Class ( En 61140 ) : I, Protection Rating ( Din En 60529 ) : Ip40, Impact Resistance Level In Accordance With Iec 62262: Ik02 / 0, 2 J, Testing Temperature Of Wire Glow Test In Accordance With Iec 60695-2-11: 650 °C. With Electronic Transformer, Digitally Dimmable ( Dali ) . Weight 3, 4 Kg I / C C Connection Etc As Reqd. 67 Supplying & Fixing Of 600 Mm Sweep Wall Fans With Control Buttons Suitable To Operate On Single Phase 240 Volts 50 Hz Ac Supply I / C Connection Etc As Reqd. 68 Supplying & Fixing Of 600 Mm Sweep Mist / Fog Air Standing Fans With Control Buttons & Portable Trolley And Water Tank & Suitable To Operate On Single Phase 240 Volts 50 Hz Ac Supply I / C Connection Etc As Reqd. 69 Supplying, Installation, Testing & Commissioning Of 900 Mm Sweep Fancy Or Decorative Ceiling Fan With Advanced Technology Less Motor Noise, Complete Including Wiring The Down Rod Of 40 Cm With 1.5 Sq. Mm. Frls Pvc Insulated, Copper Conductor, Single Core Cable, Including Providing And Fixing Phenolic Laminated Sheet Cover On The Fan Box Etc. Complete As Required. 70 Supplying, Installation, Testing & Commissioning Of 1200 Mm Sweep Fancy Or Decorative Ceiling Fan With Advanced Technology Less Motor Noise, Complete Including Wiring The Down Rod Of 40 Cm With 1.5 Sq. Mm. Frls Pvc Insulated, Copper Conductor, Single Core Cable, Including Providing And Fixing Phenolic Laminated Sheet Cover On The Fan Box Etc. Complete As Required. 71 Supplying, Installation, Testing & Commissioning Of 1200 Mm Sweep Ceiling Fancomplete Including Wiring The Down Rod Of 40 Cm With 1.5 Sq. Mm. Frls Pvc Insulated, Copper Conductor, Single Core Cable, Including Providing And Fixing Phenolic Laminated Sheet Cover On The Fan Box Etc. Complete As Required. 72 Supplying & Fixing Of 150 Mm Sweep Fresh Air Fan Complete With Shutter I / C Making Hole Of Suitable Size I / C Connections, Interconnections Etc. Complete As Reqd. 73 Supplying & Fixing Of Metal Finish Standing Candle Stand / Cabdle Holder With 5 Nos Of Additional Candlesi / C Connections, Interconnections Etc. Complete As Reqd. 74 Supplying, Installation, Testing & Commissioning Of 25 Ltrs Capacity 5 Star Rating Vertical Type Water Heating Type Geyser, Having Heating Element Of Titanium Enamelled, Suitable To Operate Of Single Phase 240 Volts 50 Hz Complete With All Connection With Flexible Pipe Etc Complete As Reqd. 75 Supplying, Installation, Testing & Commissioning Of 35 Ltrs Capacity 5 Star Rating Vertical Type Water Heating Type Geyser, Having Heating Element Of Titanium Enamelled, Suitable To Operate Of Single Phase 240 Volts 50 Hz Complete With All Connection With Flexible Pipe Etc Complete As Reqd. 76 Supplying, Installation, Testing & Commissioning Of Following Sizes ( Screen Size ) Uhd Led Tv, Full Hd 3840 X 2160 Pixels With Inbuilt Speaker Of 20 Watt ( Record, Pause, Rewinding, Live Shows ) , Connectivity 2 Hdmi Port & 2 Usb Port, Wifi, Bluetooth With Complete All Accessories Etc. As Reqd. ( A ) 55” Uhd Led Tv 77 ( B ) 43” Uhd Led Tv 78 Supplying, Installation, Testing & Commissioning Of Energy Efficient Following 2.0 Tr Capacity Hot & Cold One Way Cassette Type Air Conditioner Unit Suitable For 230Volts, Single Phase, Ac Supply, Capable Of Performing Cooling, Air Circulating & Filtering Complete Connection Including Repairing Of Wall With Minor Civil Work I / C Making Hole By Core Cutting Machine At Site Etc. As Required. 79 Supplying & Replacement Of High Wall Split Air Conditioner Of Inverter Type Of Capacity Not Less Than 2.0Tr Complete With Outdoor Condensing Unit & Wall Mounted Evaporating Unit Having Cordless Remote Control And Copper Refrigerant Pipe ( Upto 4 Meters Length ) , Capable Of Filtering, Cooling, Dehumidifying And Suitable For Operation On Eco-Friendly Gas ( R407 / R410 / R32 ) , Single Phase, 230Volts, Ac Supply ( 5 Star Rating Model, As Certified By Bee ) Including Mounting / Fitting Of Indoor / Outdoor Units, Insulation The Suction & Discharge Pipe With Epf Tubing, Charging Of Refrigerant, Providing Of Electrical Connections, Interconnections With Suitable Size Cable And Providing Of Drain Pipe Etc. Complete With Testing & Commissioning As Required At Site. 80 Supplying, Installation, Testing & Commissioning Of High Wall Split Air Conditioner Of Invertor Type Of Capacity Not Less Than 1.5Tr Complete With Outdoor Condensing Unit & Wall Mounted Evaporating Unit Having Cordless Remote Control And Copper Refrigerant Pipe ( Upto 4 Meters Length ) , Capable Of Filtering, Cooling, Dehumidifying And Suitable For Operation On Eco-Friendly Gas ( R407 / R410 / R32 ) , Single Phase, 230Volts, Ac Supply ( 5 Star Rating Model, As Certified By Bee ) Including Mounting / Fitting Of Indoor / Outdoor Units, Insulation The Suction & Discharge Pipe With Epf Tubing, Charging Of Refrigerant, Providing Of Electrical Connections, Interconnections With Suitable Size Cable And Providing Of Drain Pipe Etc. Complete As Required At Site. 81 Supplying, Installation, Testing And Commissioning Of 5 Kva, Copper Wounded, Wall Mounted Voltage Stabilizer With Led Display, Surge Indicator, Automatic Reset Suitable For 1.5 / 2.0 Tr Ac Unit Complete Etc. As Required. 82 Providing & Laying Of Refrigerant Suitable Size Copper Piping ( 3 / 8 / 5 / 8 & 1 / 4 Dia ) From Indoor Unit To Outdoor Unit Of Split Type Ac Duly Insulated Along With 9Mm Thick Nitrile Sleeve Of Ac Units To Drain Pipe Etc. As Reqd. 83 Providing & Fixing Rigid Pvc Piping Of Following Sizes Complete With Fittings, Supports Etc. Duly Insulated With 6Mm Thickness Of Closed Cell Nitrile Rubber Complete As Required And As Per Specifications ( A ) 25 Mm Dia 84 Providing Control Cum Transmission Screened Cable Wiring With 2.5 Sqmm 3 Core Interconnecting Sheilded Wire Running From Indoor Unit To Outdoor Unit In Existing Conduit / Surface For Indoor & Outdoor Units Complete Etc. As Required. 85 Supplying, Installation, Testing & Commissioning Of Air Purifier Technology Based Having 3 Stage Filteration I.E Pre-Filter:Traps Larger Particles Such As Hair And Dust, Particulate Filter: Captures Smaller Particles Such As Pm2.5, Bacteria, Virus & Carbon Filter: Reduces Gases And Odors Which Restrict The 99.99% Air Pollutant Particles, 3 Times In An Hour In A 325 Square Feet Room, Power Consumption Of 10-12 Wattsuitable To Operate On Single Phase 240 Volts 50 Hz Ac Supply Etc. Complete As Required. 86 Supplying, Installation, Testing & Commissioning Of Stains Steel Panel Pedestal Type With G.I. Cabinet Storage Type Water Cooler 150 / 150 Ltr. Capacity, Fully Stainless Steel Suitable For Operation On 230V + 10% 50 Hz Single Phase Ac Supply Including Making Water Line & Electrical Connection Etc. As Reqd. 87 Supplying, Installation, Testing & Commissioning Of Reverse Osmosis Purifier 50Lph Basic On Line Complete I / C Plumbing Work As Per Following Specification Etc. As Reqd. ( A ) Dimension ( Wxdxh ) : 460X250x790 ( B ) Input Power Rating : 230V Ac, 50Hz ( C ) Production Capacity : 50Lph ( D ) Ro Membrane : 80Gpd X 4 Nos. ( E ) Power Consumption : 120W ( F ) Weight In Kg : 45 ( G ) % Of Rejection In Tds : 90% ( Approx ) 88 Supplying, Installation, Testing & Commissioning Of 1 Hp 0.75 Kw Single Phase Self Priming Fresh Water Pump Set Complete With Tefc Motor Class B Insulation Suitable To Operate On Single Phase 240 Volts Ac Supply Complete With All Plumbing And Related Accessories Etc. As Reqd. 89 Supplying, Installation, Testing & Commissioning Of 1 Hp Capacity Of Pressure Booster Pump Set Suitable For Maintaining Water Pressure For 4-5 Nos Of Bathrooms With 24 Ltrs Capacity Of Pressure Tank Suitable For Operation On 1-Phase 240 Volts 50 Hz Ac Supply I / C All Connection With Existing Pipe Lines Complete As Reqd. 90 Supplying, Installation, Testing & Commissioning Of 0.5-0.6 Hp Capacity Of Pressure Booster Pump Set Suitable For Maintaining Water Pressure For 4-5 Nos Of Bathrooms With 24 Ltrs Capacity Of Pressure Tank Suitable For Operation On 1-Phase 240 Volts 50 Hz Ac Supply I / C All Connection With Existing Pipe Lines Complete As Reqd. 91 Supplying, Laying And Fixing Of Following Size Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Armoured Power Cable Of 1.1 Kv Grade In Following Manner Etc. As Reqd. ( A ) 3 X 10 Sq.Mm On Wall Surface 92 ( B ) 3 X 10 Sq.Mm In Ground Including Excavation And Refilling The Trench Etc As Required, But Excluding Sand Cushioning And Protective Covering 93 ( C ) 4 X 25 Sq.Mm On Wall Surface 94 ( D ) 4 X 25 Sq.Mm In Ground Including Excavation And Refilling The Trench Etc As Required, But Excluding Sand Cushioning And Protective Covering 95 Less For Credit Of Following Old Dismantle Mateial Etc. Complete As Required. ( A ) Assorted Pvc Copper Wire / Pipe 96 ( B ) Scrap Iron / Conduit / Box 97 ( C ) Assorted Xlpe Aluminium Cable 98 ( D ) Various Type Light Fittings 99 ( E ) 1200 / 1400Mm Ceiling Fan 100 ( F ) Fresh Air Fan 101 ( G ) Geyser ( Assorted ) 102 ( H ) 1.5 / 2.0Tr Split Ac Units 103 ( I ) Tv 32 / 43 / 55 Inch 104 ( J ) Water Cooler 105 ( K ) R.O. 106 ( L ) 0.5 / 1Hp Pump Sets 107 ( M ) Assorted Electrical Material Such As Dbs, Mcbs, Isolator, Switch-Socket, Plate, Plug Top, Ceiling Rose Etc.
Contract Date : 30 Aug, 2022   |   Contract Value : 54.83 Lakhs
BRR : 8762559 Tender For Maintenance And Repair To External Water Supply And External Electric Supply, External Street Lights And Connected Work At Ebs Babugarh Under Ge (North) Meerut Cantt.; 1 M&L for laying andtesting 20 mm bore GI tubing medium grade with all required fittings and fixtures laid in trenches, on the ground or on supports or fixed to walls incl taking up or down old unsv pipe making good of disturbed surfaces of roads, path ways etc. complete all as specified and directed. 2 All as per Srl item No 1 but 25mm bore complete all as specified and directed. 3 All as per Srl item No 1 but 40mm bore complete all as specified and directed. 4 All as per Srl item No 1but 50mm bore complete all as specified and directed. 5 M&L for laying andtesting 150 mm bore DI pipes with spigot and socket ends centrifugally cast class K7 in any length suitable for and including tyton joints laid in trenches including necessary cut to length to match the existing fitting / pipes incl taking up or down old unsv pipe making good of disturbed surfaces of roads, path ways etc. complete all as specified and directed. 6 All as per Srl item No. 6 but 100mm bore complete all as specified and directed. 7 All as per Srl item No. 6 but 80mm bore complete all as specified and directed. 8 M&L for taking up or down 80 to 150 mm bore Cast Iron water mains (including all fittings), with spigot and socket ends and lead joints cleaning the pipes free from sedimentation / scaling etc. and re-laying the same in trenches, on the ground or on supports or fixed to walls incl testing complete all as specified and directed. 9 Note for item No 1 to 9 :- Earth work shall be measured and paid separately. 10 Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for laying of Cable or Pipe, electric pole, stay assembly etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/ losse soil complete all as specified and as directed. 11 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. in soft/ losse soil complete all as specified and as directed. 12 Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting pointin soft/ losse soil complete all as specified and as directed. 13 M&L forhorizontal boring for road crossing for laying upto 200 mm bore water supply pipe lines across under roads, foot path etc. and making good disturbed areas as beforecomplete all as specified and directed. 14 M&L for lead joint and testing for 80 to 100 mm bore CI/DI pipe including spun yarn etc. for spigot & socket pipes and fittings complete all as specified and directed. 15 All as per Srlitem No. 14 but 150mm bore complete all as specified and directed. 16 M&L for CI or DI fittings for spigot and socket pipes such as bends (any type, radius and angle), tapers any type (straight, bend, increasing, decreasing or double socket etc), tee pieces, D clamps, angle branch, cross (all sockets or socket & spigot collars, caps and plugs for joining up to 200 mm bore CI pipe in repairs complete all as specified and directed. 17 S&F and testing, 80mm dia CI non rising type sluice valve both ends flanged with CI body, ISI marked, IS 14846, pressure PN 1.6 with brass spindle with clamps and check nuts, operating hand wheel including dismantle and remove the unserviceable sluice valve complete all as specified and directed. 18 All as per Srlitem No. 17 but 100mm bore complete all as specified and directed. 19 All as per Srlitem No. 17 but 150mm bore complete all as specified and directed. 20 Supply and fix Dual plates CI wafer type Non Return / Check Butterfly valve, 100 mm bore tested to pressure of 15Kg/Sqcm flanged type including necessary heavy duty gasket, G I Bolts, G I Nuts, G I Washers etc. incl taking down old u/s complete all as specified and directed. 21 All as per Srlitem No. 20 but 150mm bore complete all as specified and directed. 22 M&L for dismantling of defective 80 mm dia sluice valve for repairssuch as repacking stuffing box of sluice valve spindle, refacing, grinding, stuffing and threading of spindle, replacement of worn out check nut, repairs to gate assembly replacement of jointing materials such as rubber sheets, nuts, bolts & washers, gland rope and refixing in its original position, testing on completion etc. complete all as specified and directed. 23 All as per Srlitem No. 22 but 100mm bore complete all as specified and directed. 24 All as per Srlitem No. 22 but 150mm bore complete all as specified and directed. 25 S&F and testing, 20 mm bore, gun metal gate valve / ball valve, ISI marked, hand lever / iron wheel head operated, screwedat both ends for iron pipes and fixed including taking down of old unsv gate valve complete all as specified and directed. 26 All as per Srlitem No. 25 but 25mm bore complete all as specified and directed. 27 All as per Srlitem No.25 but 40mm bore complete all as specified and directed. 28 All as per Srlitem No.25 but 50mm bore complete all as specified and directed. 29 S&F CPVC Ball valve 50mm OD alongwith necessary leak proof CPVC paste / gum incl taking down old u/s complete all as specified and directed. Make Astral / Supreme / Finolex 30 All as per Srlitem No.29 but 40mm bore complete all as specified and directed. 31 All as per Srlitem No.29 but 32mm bore complete all as specified and directed. 32 All as per Srlitem No.29 but 25mm bore complete all as specified and directed. 33 Supply & laying in trenches / floor or fixed to wall / roof using suitable size MS Clamps duly painted, CPVC pipes SDR 11 and incl plain CPVC SDR 11 fittings of size 50mm OD alongwith necessary leak proof CPVC paste / gum incl taking down old u/s complete all as specified and directed. 34 All as per Srlitem No.33 but 40mm bore complete all as specified and directed. 35 All as per Srlitem No.33 but 25mm bore complete all as specified and directed. 36 M&L for repair / rectification of leakages in water supply distribution GI lines of 20 to 25 mm dia incl necessary excavation, returning filling as per site requirement, tightening of loose joints of GI unions, elbows, sockets, tees etc. cutting / threading if required all as directed.Note:The complaints for the above work are to be collected by the contractor rep from MES maint incharge of EBS Babugarh on daily basis and trades men are to be detailed immediately. Required stationery such as complaint register, Job cards etc shall be arranged and maintained by the contractor. Transport and Tools required for attending the complaints are to be arranged by the contractor. 37 All as per Srlitem No.36 but GI tubing 40 to 50 mm dia complete all as specified and directed. 38 M&L for attending break down of water supply pipe line and repair to CI / DI water mains of size 80 mm to 150 mm dia at a given notice including necessary excavation, earth work by manual or using special T&P such as JCB etc. dewatering from the trenches by using pumps or any other mode, rectification of leakages, fixing of CI specials such as collars bends / tail peaces / D-clamp joints etc. and arresting the leakage, testing all as directed. Note: Specials, joint materials only measured and paid separately. 39 M & L for Construction of brick masonry valve chamber of size 1000 x 1000 x 1000 mm (Internal dimenssions) with PCC foundation 1:4:8 type D2 using 40 mm graded stone aggregate 150 mm thick, 150 mm wide off sets allround over 100 mm thick hard core, brick masonry walls built in CM 1:6, 50 mm thick PCC 1:2:4 Type B1 coping finished even and smooth, rendering 10 mm thick in cement mortar (1:6) finished even and smooth, with out using extra cement internally and 150mm below GL externally and top of floor including excavation, earth work in soft / loose soil, 5 mm thick MS sheet cover fixed on 50 mm x 50 mm x 6 mm thick angle iron frame with hold fasts embedded in PCC coping with locking arrangement, mild steel handle and painting to steel surfaces with two coats of synthetic enamel paint over one coat of red oxide primer including disposal of surplus soil to a distance not exceeding 50 m etc. complete all as specified and directed. 40 All as per Item No. 39 but of size 600x600x600 complete all as specified and directed. 41 M&L for cleaning of 100000 Gallon RCC over head reservoir of any type, any height using construction of staging or by mechanical means for carrying out the inner surface of the walls and ceilings of the tank shall be cleaned with high pressure jet pump after emptying the water in the tank. After thorough cleaning of the tank, the cleaning water and sludge is to be removed by using pump and the sludge has to be disposed off at a place as directed. After removing thesludge from tank, the tank shall be cleaned thoroughly by using high pressure water pump first and again cleaned the tank by using high pressure vaccume pump and after removing the sludge / dirt completely from the tank the floor and inner surfaces of the tank shall be cleaned by using a industrial vaccum cleaner and the tank shall be made fully dust free. After made the tank dirt free the inner surfaces of walls and ceiling of the tank shall be treated with anti bacterial agents. After the treatment as mentioned above, the inner surface of walls and ceiling shall be treated with UV Radiator. After complete treatment is carried out, the all pipes inlet, over flow, delivery, wash out, ladder and doors shall be painted with two coats of synthetic enamel black paint after thorough cleaning the surfaces and also the surfaces of sluice valves shall be painted with PO red paint and writing Capacity of tank, date of cleaning and due date of cleaning on wall as specified and as directed. Incl replacing of u/s wire mesh of ventilations of the tank with new mesh complete all as directed BY Engineer-in-Charge.Notes for item No : (1) The unit rate quoted deemed to be including draining of water with mechanical equipment and working in water and mud etc. (2) The unit rate quoted deemed to be include all safety precautions which shall be taken while working on RCC over head tank / under ground sump and contractor or his engineer shall be available during execution of the job. (3) Lightning arrangements if required to be provided by the contractor temporarily at his own arrangements and the amount quoted for that is deemed to be inclusive in the unit rate and electricity/ diesel shall not be provided by MES. 42 Disconnecting the suction and delivery pipe line and electric connections of submersible pump set 25 / 30 HP and removing it from its original position alongwith pipes and fittings carefully by using chain pulley and tripod, transporting the same to the authorised work shop for necessary maint / repairs and refixing the same in its original position after repairs by lowering along with pipes including connecting up of water and electric connections including testing andcommissioning complete all as specified. (Depth of bore welll is upto 50 Mtr). Note: Expendable stores like cotton waste / cleaning materials, lubricants, gland packing, metal filling, machining and transportation to and from site to work shop and labour element are deemed to be included in rate quoted. 43 M&L for rewinding ofthesubmersible motor with super enamelled Copper conductor of good quality, same gauge and same No. of turns as that of existing including tying the winding and connecting the coils and bringing the connections as that of existing complete all as specified including applying insulating varnish, heating and backing the windings thoroughly for submersible motor 25 / 30 HP capacity. 44 M&L for Opening theSubmersible pumpset up to 30 HP pump sets for inspection, repairs and reassembling the pump and motor as per the original assembly after repairs / replacing the worn out unserviceable parts with new parts as ordered, including cleaning replacing the minor items like packing bolts, nuts washers and MS clamps etc and applying one coat of approved hammertene spray paint on exposed steel surface, making the pump and motor fully serviceable and testing after refixing and commissioning all as directed for satisfactory operation on its full load. Note: Spare parts will be measured and paid under relevant item separately. All minor consumables / Eqpt / Tpt required shall be deemed as included in the rates quoted. 45 Supply only Motor bearing, bush complete set inlet/outlet side suitable for submersible pump set up to 30 HP capacity complete all as specified and directed. 46 All as per Srlitem No.45 but Impeller complete all as specified and directed. 47 All as per Srlitem No.45 but Pump NRV complete all as specified and directed. 48 All as per Srlitem No.45 but SS sleeves complete all as specified and directed. 49 All as per Srlitem No. 45 but Neck ring stage casing complete all as specified and directed. 50 All as per Srlitem No.45 but Sand guard complete all as specified and directed. 51 All as per Srlitem No.45 but Oil seal complete all as specified and directed. 52 All as per Srlitem No.45 but Bowel case complete all as specified and directed. 53 All as per Srlitem No.45 but stainless steel shaft of standard size complete all as specified and directed. 54 S&F in repairs, flexible submersible cable 3 core 10 Sqmm with stranded Copper conductor, 1100 volts grade,PVC insulated, PVC sheathed, connecting with necessary end ferrules / water proof joints complete all as specified and directed. 55 S&F in repairs, fully automatic star delta motor starter suitable for 25 / 30 HP submersible pumpset, 3 phase, 415 V with relay range of 45 to 75 Amps incl enclosure complete all as specified and directed. . Make - Havells/Schneider/L&T 56 Supplying, installing, erecting, testing and commissioning, factory made and tested, pump panel board outdoor type, dimensions not less than 1.0 m (L) X 0.5 m (W) X 1.2 m (H), suitable for 3 phase, 415 Volts, 50 Hz system with 200 Amps capacity aluminium bus bar. The panle should be dust and vermin proof, IP 56 class protection and made of 3.15 mm thick CRCA MS sheet with doble door, both sides openable inclusive of locking arrangement, suitable opening for vent and cable entry consisting of Electronic fully automatic star delta starter-01 No. having automatic phase sequence corrector, programmable time with input supply by MCCB of 100 Amps rating, digital type Ammeter and Voltmeter, selector switch, CTS, RYB including indication lampsetc, suitable for submersible pump-motor set of size 25/30 HP, erected on 50X50X6mm thick angle iron frame work, bottom channel of size: 70X40X5 mm powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside , grouted in floor including complete earth work such as excavation, removing and returning filling and required PCC work for the erection of the panel board, complete all as specified and as directed. 57 S&F in repairs, Pressure Gauge, 100mm dia, 0 - 14 Kgs rating complete all as specified and directed. 58 Supply of Calcium hypochlorite having 65% to 70% strength chlorine for disinfection purpose in white coloured powder form for water treatment in sealed non returnable containers in the store yard of EBS Babugarh complete all as specified and directed. Make- RENSA/Purichlor 59 M&L for repairs of dosing system consisting of Syntex make 100Ltr capacity poly Ethelene (PE) tank, Fibre reinforced plastic (FRP) lid have port hole for pouring calcium based granual disinfectant chemical and water when necessary and operatedwith 1 phase motor , 240V complete to the satisfactory operation of the system complete all as specified and directed. 60 M&L for the existing Microprocessor based circuit type water level device consist of seven segment 2 LED display fitted in the control panel operated the pump to automatic switch off when the water level in OH tank reaches the maximum level, visual display with audio alarm on low water level in tank complete to the satisfactory operation of the system complete all as specified and directed. 61 M&L for Structural Steel Work, made out ofFe 410-W (Gde-E-250) quality-A Rolled Mild Steel Channel, Angle or Tee Sections, MS sheet with hinges & locking arrangementsetc. cut to shape / ordinary length, drilled and countersunk for Screws / Bolts, including bending and welding duly painted with 2 coats of Anti Corrossive Synthetic enamel paint over a coat of Zinc Chromate complete all as specified and directed. 62 M & L for carrying out B check of 320 KVA DG set through authorised service dealer of the manufacturer including replacement of B check service kit complete all as per manufacturers standards complete all as specified and directed. 63 All as per Srlitem No.62 but for 50 KVA DG set complete all as specified and directed. 64 All as per Srlitem No.62 but for 15 KVA DG set complete all as specified and directed. 65 M&L for draining out old engine oil, S&F Engine lubricanting oil conforming to the engine manufacturer requirement of classification SAE 15 W 40 lube oil complete all as specified and directed.Make : Servo / Castrol 66 M & L for Overhauling of radiator including dismantling from engine,opening of radiator, cleaning of radiator tubes, fans with acid and removing the scaling & dust, brazing the copper tubes, arresting the leakages completely etc, including renewal of all connecting parts i.e. radiator hose pipe with clamps, bolts, nuts, washers, rubber bush packing material, etc. and re assembling the radiator and fixing with DG set properly in original position, checking the alignment, making proper hose connection, testing for smooth operation complete all as directed for DG set of any type/make having capacity of 320 kVA.NOTE: The cost of renewed parts is deemed to be included in unit rate quoted by contractor. No extra cost shall be paid to the contractor for the same. 67 All as per Srlitem No.66 but for 50 KVA DG set complete all as specified and directed. 68 All as per Srlitem No.66 but for 15 KVA DG set complete all as specified and directed. 69 M&L for taking out injector of DG set of capacity 320 kVA, disconnection and opening of fuel injector assembly, carrying complete overhauling/servicing of fuel injector system, including replacement of injector kit, checking of pressure, complete for each injector and reassembling the same in original positionby making proper fuel connection and testing for smooth operation complete all as specified and directed.Note: Cost of renewal of parts to be measured and paid separately. 70 Supply only nozzle holder for 320 kVA DG set of any make complete all as specified and directed. 71 M&L for opening /taking out fuel injection pump (FIP) of DG set of any type/make of capacity 320 kVA, disconnecting of fuel injector line, carrying out complete overhauling servicing of injector pump, calibration of fuel pump as per manufacturer instruction, assembling of the same wit DG set properly in original position, checking the alignment, making proper fuel connection including renewal of unserviceable/defective minor parts like seal O ring, fuel pump gasket, gear, technometer, bushing, technometer cover, fuel pump, gear housing, fuel pump gear, etc. and testing for smooth operation complete all as directed after renewal of following major parts if found defective/unserviceable.NOTE: The cost of renewed parts is deemed to be included in unit rate quoted by contractor. No extra cost shall be paid to the contractor for the same. 72 Supply only Plunger and return spring for 320 kVA DG set of any make/type complete all as specified and directed. 73 Supply only control rod for 320 kVA DG set of any make/type complete all as specified and directed. 74 Supply only Plunger barrel for 320 kVA DG set of any make/type complete all as specified and directed. 75 Supply only delivery valve and spring for 320 kVA DG set of any make/type complete all as specified and directed. 76 Supply only HP line for 320 kVA DG set of any make/type complete all as specified and directed. 77 Supply only pump element for 320 kVA DG set of any make/type complete all as specified and directed. 78 Supply only roller tappet for 320 kVA DG set of any make/type complete all as specified and directed. 79 Supply only nozzle for 320 kVA DG set of any make/type complete all as specified and directed. 80 Supply & fix flexible coupling for 320 KVA DG Set including alignment of alternator with engine complete all as specified and directed. 81 All as per Srlitem No.80 but50 KVA DG set complete all as specified and directed. 82 All as per Srlitem No.80 but 15 KVA DG set complete all as specified and directed. 83 M & L for alternator servicing, decarbonising the alternator coils, re-varnishing, heating, bearing checking, re-greasing and termination, tinning for 320 KVA DG Set complete all as specified and directed. 84 All as per Srlitem No.83 but for 50 KVA DG set complete all as specified and directed. 85 All as per Srlitem No.83 but for 15 KVA DG set complete all as specified and directed. 86 Supply and filling coolant of superior quality complete all as specified and directed. Make Servo / Castrol 87 M&L for cleaning of diesel tank of DG Set 320 KVAincluding replacement of worn-out pipe line and measuring scale and fixing in original position and make it leak proofwith necessary clamps complete all as specified and directed. 88 Supply and fixing battery 12V 180 AH including replacement of terminals and connecting lead suitable length and size of multi stranded copper wire complete all as specified and directed. .Make:- Exide/Amaron 89 All as per Srl item No.88 but 12V,100 AH complete all as specified and directed. 90 Dismantling of burnt/defective wiring system of DG Set 320 KVA and M&L for complete wiring of required size with sleeves thimbles, lugs etc for DG set complete all as specified and directed. 91 All as per Srlitem No.90 but for 50 KVA DG set complete all as specified and directed. 92 All as per Srlitem No.90 but for 15 KVA DG set complete all as specified and directed. 93 Disconnection and taking out the unserviceable turbo charger assembly of DG Set 320 KVA and taking to workshop, strip opening of turbo charger and replacement of repair kit, re-assembling and fixing back to engine and testing complete all as specified and directed. 94 All as per Srlitem No.93 but for 15 to 50 KVA DG set complete all as specified and directed. 95 M & L for servicing, repairing, maintenance of self starter assembly of DG Set 320 KVA, complete with replacement of switch magnet,bush gear, O ring assembly, bush set, sealing kit, clutch assemble with new ones and refixing the same in original positioncomplete all as specified and directed . NOTE: The cost of replacement of items mentioned in the description is deemed to be included in the rate quoted by the contractor and no extra payement will be done for replacing those items. 96 Supply only armature for 320 kVA DG setcomplete all as specified and directed. 97 Supply only solenoid switch for 320 kVA DG set complete all as specified and directed. 98 Supply only field coil for 320 kVA DG set complete all as specified and directed. 99 All as per Srlitem No 96but for 15 to 50 KVA DG set complete all as specified and directed. 100 All as per Srlitem No 97but for 15 to 50 KVA DG set complete all as specified and directed. 101 All as per Srlitem No 98 but for 15 to 50 KVA DG set complete all as specified and directed. 102 Supply & Replace Fan belt set of existing size complete of DG Set 320 KVAcomplete all as specified and directed. 103 All as per Srlitem No. 102 but for 15 to 50 KVA DG set complete all as specified and directed. 104 Supply & Replace Oil temperature gauge 0-130C complete all as specified and directed. 105 Supply & Replace Water temperature gauge 0-130C complete all as specified and directed. 106 Supply & Replace DC ammeter 0-50 complete all as specified and directed. 107 Supply & Replace Tachometer 0-2500 RPM complete all as specified and directed. 108 Supply & Replace Ignition switch DC with Key complete all as specified and directed. 109 Supply & Replace Oil pressure gauge 0-7 Kg/Cm complete all as specified and directed. 110 Supply & Replace Distilled Water complete all as specified and directed. 111 Supply & Replace Battery lead terminals complete all as specified and directed. 112 S & F automatic battery charger for 12/24V battery complete with all necessary controls and fixing arrangments complete all as specified and directed. 113 S&F in replacement of DG set door lock with handle with double key of all doors of DG set canopy of any capacitycomplete all as specified and directed. 114 S&F in replacement of Automatic voltage Regulator (AVR) suitable for DG Set of320 KVAcapacity with and including taking out old AVR and making all connectiontesting for smooth operation complete all as specified and directed. 115 All as per Srlitem No above here-in-before butfor 50 KVA DG set complete all as specified and directed. 116 Supply, fixing & testing Volt meter 0-500 Volts, 96mm x 96mm, digital type complete all as specified and directed. Make : AE/ Rishab/Meco/Enercon. 117 Supply, fixing & testing Ammeter 0-400 Amps, 96mm x 96mm, digital type complete all as specified and directed. Make : AE/ Rishab/Meco /Enercon. 118 S&F in repairs, thermal over load relay of various ranges starting from 3 Amps to 15 Amps complete all as specified and directed. Make : Type ML0 to ML 1.5 of L&T /BCH/ C & S Electric / Siemens. 119 S&F in repairs, thermal over load relay of various ranges starting from 9 Amps to 42 Amps complete all as specified and directed.Make : Type ML2/ML3 of L&T or equivalent of BCH/ C & S Electric / Siemens. 120 S&F in repairs of single phase preventor, auxiliary volts 415 volts, suitable for 3 phase AC supply complete all as specified and directed. 121 S&F in repairs, testing push buttons with thermo plastic body actuators with carrier having flush type push button complete all as specified and directed.Make : BCH/C & S Electric /L&T / Siemens. 122 S&F in repairs, testing pilot lamps LED type with integral circuit & cluster LED suitable for operating at 240 /220 Volts complete all as specified and directed. Make : BCH/C & S Electric /L&T / Siemens. 123 Preparation of the existing surfaces of electric panels of any description and size & applying two coats of synthetic enamelled paint of approved shade complete including writing details & information on its panels with paints in the pattern & style to match with the words as existing all as directed. 124 M&L for preventive maintenance and servicing of AMF panel of any capacity DG set installed at site incl checking of connections of cables and tightening of loose wiring, nuts and bolts of panel andbus bar chamber. The cost includes minor items like replacement oflugs, control wiring and ferrules etc. complete all as specified and directed. 125 S&F in replacement, asbestos rope of 19 mm dia around of the exhaust pipe of diesel engine any cap complete all as specified and directed. 126 M&L for repair of burnt / perished cable ends on incoming and outgoing feeders of panel equipments and other machinery including cutting of burnt ends preparing / dressing of cables end crimp with suitable size of cable lugs (cable lugs will be measured and paid seperately) incl providing, fixing suitable nuts / bolts / washers etc. forupto 95Sqmm 3.5 core cable 127 All as per Srlitem No.1 but 120Sqmm to 240 sqmm 3.5 core complete all as specified and directed. 128 S&F Al lugs for cable size 50 to 70 sqmm complete all as specified and directed. 129 S&F Al lugs for cable size 95 to 120 sqmm complete all as specified and directed. 130 S&F Al lugs for cable size 240 to 300 sqmm complete all as specified and directed. 131 S&F in replacement,synthetic rubber insulated mats in replacement forinstallations size 2 mtr X 01 mtr X 2.5 mm thick, for voltage upto 11 kV, ISI marked, as per IS 15652-2006 complete all as specified and directed. 132 M&L for repairs of existing On Load/off load Change Over Switch, 4P, 400 Amps, 415 volts by cleaning/ decarbonising,replacement of worn out contacts,lugs and handle arrangement to the smooth function of the item complete all as specified and directed. 133 S&F in repairs of Off load change over switch 4 pole, 415V, AC , 100 A rating with enclosure type complete all as specified and directed. . Make- HPL 134 S&F in repairs, connect,MCCB 4 Pole, 415V, adjustable type, 400 Amps,breaking capacity of 36 KA with cable separators complete all as specified and directed. 135 All as per Srlitem No.9 but 200 Amps, 36KA complete all as specified and directed. 136 All as per Srlitem No.9 but 160 Amps, 36 KA complete all as specified and directed. 137 All as per Srlitem No.9 but 100 Amps, 16 KA complete all as specified and directed. 138 S&F in repairs, connect,MCCB 3 Pole, 415V, 125 Amps, 16 KA complete all as specified and directed. 139 All as per Srlitem No.13 but 63 to 100 Amps, 16KA complete all as specified and directed. 140 Testing and calibration of HT VCB 11 KV complete with primary and secondary test as required including checking of wiring of all electrical measuring instrument and resetting of relay and proper alignment mechanical system for smooth functioning and tripping at any type offault developed in feeders complete all as specified and directed by Engineer-in-Charge. Note:Contractor will submit primary and secondary test record at the time of calibration of HT VCB, duly signed by the technical rep of manufacturer/authorised dealer to Engineer in Charge. The rate quoted by the contractor shall be deemed to include the cost of this provision incl T&P required for injecting regulated high current. 141 Disconnecting of HT supply from 11 KV VCB of any make/type/capacity for repair works, servicing and taking out trolley with completedecarbonizing the contactpoints, cleaning with CRCsolution and inner body clean with vaccum cleaner etc and incl replacement of defective minor parts like lugs, terminals, ferrule,control wiring, nut bolts, HRC fuse links etc found during servicing. Reassembling and testing of relays for trippingtime setting over current setting, earth fault setting etc including checking of vaccume interrupter, tripping mechanism etc after servicing complete all as specified and directed by Engineer-in-Charge. 142 M&L for servicing/repair of VCB spring charging motor 24/220 Volt DC/AC for 11KV VCB, of existing make, type, size, capacity with driving gear including ensuring the manual operation of charging complete testing to the satisfactory operation of VCB charging complete all as specified and directed. Note: (1) HT VCB above servicing shall be carried out only by qualified and experienced person and prior approval shall be obtained from GE.(2) The major spare parts required during above servicing will be measured and paid separately under relevant item of schedule. 143 Supply only open/closed auxiliary contacts suitable for upto 630 Amps HT VCB fixed in repairs. As per existing sample. 144 Supply only under voltage release suitable for upto 630 Amps HT VCB fixed in repairs. As per existing sample. 145 Supply only under/over frequency release suitable for upto 630 Amps HT VCB fixed in repairs. As per existing sample. 146 Supply only Shunt trip closing coil assembly 110/220 volts, DC/AC suitable for upto 630 Amps, HT VCB complete all as specified and directed. 147 Supply only Shunt trip tripping coil assembly 110/220 volts, DC/AC suitable for upto 630 Amps, HT VCB complete all as specified and directed. 148 Supply only spring charging Motor Cut off switch as per existing samplesuitable for 11 KV VCB complete all as specified and directed. 149 M&L for cable jointing kit for 11 KV (Earthed) grade for indoor terminations heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120sqmm to 185 sqmm incl taking out old jointing kit of any make and type complete all as specified and directed. 150 All as per Srlitem No.149 but out door type of size 120 to 185 sqmm HT cable complete all as specified and directed. 151 All as per Srlitem No.149 but out door type of size 95 sqmm HT cable complete all as specified and directed. 152 M&L for cable jointing kit for 1100 volts grade (LT cable) for outdoor terminations heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 240 sqmm to 300 sqmm incl taking out old jointing kit of any make and type all as specified and directed. 153 All as per Srl item No. 152 but for LT cable of size 120 sqmm to 185 sqmm complete all as specified and directed. 154 M&L for laying in repairs of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor, 11000 volts earthed grade of size 95 sqmm 3 core cable laid in trenches/ ducts or fixed to walls / poles or passed through pipes all as directed. 155 All as per Srlitem No.154 but out door type of size 3 core x 120 sqmm complete all as specified and directed. 156 Supplying laying and testing XLPE insulated ,armoured , electriccable (heavy duty)1100 volt grade with stranded aluminium conductor, laid in trenches / ducts or fixed to walls / poles or passed through pipesscomplete all as specified of following sizes :- 157 All as per Srl item No.156 but 240 Sqmm, 3.5 core cable complete all as specified and directed. 158 All as per Srl item No.156 but 120 Sqmm, 3.5 core cable complete all as specified and directed. 159 All as per Srl item No.156 but 95 Sqmm, 3.5 core cable complete all as specified and directed. 160 All as per Srl item No.156 but 70 Sqmm, 3.5 core cable complete all as specified and directed. 161 All as per Srl item No.156 but 50 Sqmm, 3.5 core cable complete all as specified and directed. 162 All as per Srl item No.156 but 35 Sqmm, 3.5 core cable complete all as specified and directed. 163 All as per Srl item No.156 but 25 Sqmm, 3.5 core cable complete all as specified and directed. 164 All as per Srl item No.156 but 16 Sqmm, 4 core cable complete all as specified and directed. 165 All as per Srl item No.156 but 10 Sqmm, 2 core cable complete all as specified and directed. 166 All as per Srl item No.156 but 6 Sqmm, 2 core cable complete all as specified and directed. 167 M&L for fixing PCC cable route markers of size 700X240X75 mm at top of cable trench complete all as specified and directed. 168 Supply and spreading clean fine dry river sand in trenches for cushioning of under ground cable/ cable duct or inside the premises of transformer yard complete all as specified and as directed. Note: Only punned thickness shall be measured for payment purpose. 169 M&L for laying burnt clay fly ash old size bricks, straight or curved on plan, laid flat with width equal to length of brick, laid dry over under ground cable for protection complete all as specified and as directed. 170 M&L for Galvanized steel tubing, light grade, with all fittings for protection of cable including taking down old, rusted & corroded unsv Galvanized steel tubing complete all as specified and as directed of the following sizes:- 171 100mm bore complete all as specified and directed. 172 80mm bore complete all as specified and directed. 173 50mm bore complete all as specified and directed. 174 40mm bore complete all as specified and directed. 175 M & L for cutting hard standing/ Road cutting for taking up or laying of LT UG cable upto a depth of 15 cm and after laying of cable, well ramming to the excavated soil and repair the cutting/ exvcavated portion of road as existing or by providing suitable mixture of PCC complete all as specified and as directed. 176 M&L for providing PCC 1:4:8, type D-2, (using 40 mm graded stone aggregate) as in foundation for erection of poles complete inclding breaking and removing the old concrete complete all as specified and as directed. 177 M&L for providingPCC 1:2:4, typeB-1 (using 20 mm graded stone aggregate) as incoping to pole etc., including breaking and removing the old concrete and providing necessary form work complete all as specified and as directed. 178 M&L for lightning arresters expulsion type complete with all fittings, transmission class, max discharge capacity 65 kA suitable for 11000V grade including taking down existing unsv damaged lightening arrestor complete all as specified and as directed. 179 M&L for switch air break, gang operated, triple pole, mechanically operated, vertical/ Horizontal out door type, mounted on insulators and steel frame with operating mechanism worked from ground level for current rating upto 400 Amps suitable for 11000 volts grade complete all as specified and as directed. 180 M&L for 11000V grade, expulsion type fuses, single pole, mounted on insulators and steel frame of current rating 50 Amps including taking down old unsv expulsion fuse unit complete all as specified and as directed. 181 Surface excavation not exceeding 30 cm deep and averaging 20 cm deep and getting out in soft/ loose soil, removing of bushes, roots etc., in the transformer/ sub station yard and surrounding of two or four pole structres, treating the excavated area with anti vegetation growth chemicals, complete all as specified and directed. 182 M&L for loose filling with aggregates of gauge 40 to 80 mm of broken stone or boulders, deposited, spread and levelled in layers not exceeding 20 cm thick, watered and rammed to a true surface of transformer/ sub station yard and two pole / four polestructure complete all as specified and as directed. 183 Isolating the transformer/ voltage stabilizer by carefully dismantling the HT / LT and earth connections, draining out the oil from transformer to the required level and storing in cleaned container, opening the top cover of transformer/ voltage stabilizer and conservator tank from transformer, rectifying the defects and dismantling & replacing burnt out LT/ HT bushes, making all HT / LT connections as per the original, re-filling the transformer oil to the required level, replacing required oil seals & top cover gasket including replacing rusted unsv nut, bolt & washers and testing on completion and refixing the same for capacity upto 250 KVA complete all as specified and as directed. NOTE: (1) LT/ HT bush, transformer oil for topping up and gasket will be measured and paid separately as supply only items under relevant items of schedule 184 Disconnecting the HT/ LT connection, taking out the transformer/ voltage stabilizer from its plinth at any situation with the help of suitable crane and transporting the transformer/ voltage stabilizer to workshop for carrying out necessary repairs and bringing back and re-install in its original place of capacity upto 250 KVA complete all as specified and as directed. 185 Taking out complete core from transformers/ Voltage stabilizer of capacity upto 250 KVA cutting and removing burnt out copper/ aluminium winding and re-winding the same with super enamelled copper conductor of existing gauge togetherwith insulatingmaterials, applying varnish, drying in heating chamber, re-assembling the transformer as per the original and testing on completion complete all as specified and as directed. NOTE: Shifting of transformers/ Voltage stabiliser from installed position to civil workshop and back will be measured and paid separately under relevant items. 186 M&L for transformer/ voltage stabiliser oil filtration for removing sludge, dust, dirt and moisture from the oil, with the filtered oil having breakdown voltage (BDV) greater than 30 kV (avg) at 2.5 mm gap. NOTE: Contractor will submit BDV test value of the filtered oil after the filtration process duly signed by the technical rep of the manufacturer/authorised dealer to Engineer in Charge. The cost of this provision incl required T&P for getting the oil tested for BDV value is deemed to be included in the rate quoted by the contractor. 187 Supply only transformer oil for topping up in transformers/ Voltage stabilizer complete all as specified and as directed.. Make:Poweroil/Transol GET complete all as specified and directed. 188 Supply only bush of capacity 100 KVA Transformer 11KV/433V type complete all as specified and directed. 189 Supply only bush of capacity 250 KVA transformer 11KV/433V type complete all as specified and directed. 190 Supply only silica gel complete all as specified and directed. 191 M&L for silica gel breather and oil cup, including sufficient quantity of silica gel along with oil filling in the cup if oil level in the cup is not up to the mark, complete all as specified and as directed for thefollowing capacities of transformer:- NOTE: The cost of oil is deemed to be included in the rate quoted by the contractor. 192 Transformer of capacity 100 KVA complete all as specified and directed. 193 Transformer of capacity 250 KVA complete all as specified and directed. 194 M&L for preparation of old painted surfaces of HT 11 KV four pole structure and painting with two coats of aluminium paint over a coat of red oxide primer on all steel surfaces such as poles, channels, angles and clamps of any description and providing 04 Nos bands/ straps with synthetic enamel paint (black and white 30 cm wide each) from top of plinth block complete all as specified and as directed.. 195 All as per item No. abovehere-in-before but of two pole structure complete all as specified and directed. 196 Dismantling damaged steel tubular poles/ struts of any size complete complete all as specified and as directed. 197 M&L for erection of steel tubular, swaged poles complete with cast iron base plate of size 300 x 300 mmfinial taper plug, cap, bolts, nuts, washer and screws as specified confirming to IS type 410 SP-31 (9 M long), providing through hole of 14 mm diameter at a height of 300 mm above the planting depth for earthing arrangements, inclusive of coated with two coats of black bituminous paint throughout internally and externally up to the planting depth and the remaining portion of the exterior shall be painted with two coats of silver aluminium paint over one coat of red oxide primer complete all as specified and as directed. (Note : Excavation, earth work, PCC foundation, coping shall be measured and paid sepearately under relevnt items). 198 M&L for erection of steel tubular, swaged poles complete with cast iron base plate of size 300 x 300 mmfinial taper plug, cap, bolts, nuts, washer and screws as specified confirming to IS type 410 SP-55 (11 M long), providing through hole of 14 mm diameter at a height of 300 mm above the planting depth for earthing arrangements, inclusive of coated with two coats of black bituminous paint throughout internally and externally up to the planting depth and the remaining portion of the exterior shall be painted with two coats of silver aluminium paint over one coat of red oxide primer complete all as specified and as directed. (Note : Excavation, earth work, PCC foundation, coping shall be measured and paid sepearately under relevnt items). 199 M&L for fixing stay assembly having 20 mm diameter of stay rodincluding loop type insulator, stay clamps, etc complete with accessories as shown in electrical plate No. 1 (Excavation and Concrete work will be measured separately) complete all as specified and directed. 200 Releasing the binding of ACSR conductor of LT/ HT OH lines comprising 3 Phase 3/ 4 wire or single phase 2 wire inclduing street light conductor & earth wireof line from insulator, removing the jumper, connector, service wire, disconnecting the connection of UG cables and restreching & stringing of existing LT/HT OH lines, any size, length and span upto desired sag and rebinding the ACSR conductor on insulator, reconnecting the UG cable etc with and including suitable binding/ jumper material with aluminium wire and trimming the tree branches upto 1.5m distance around conductor to make the line functional complete all as specified and as directed. . Note: (a) Jumper/ binding material shall be deemed incldued in the rate quoted by contractor. (b) Trimming of tree branches shall be measured and paid separately under relevant items. (c) Any type conductor and any number of runs between the poles shall be measured as one span for the purpose of payment. 201 Material & Labour for attending break down/ emergent repair immediately on intimation and rectify the External electric supply complaint on LT/HT overhead lines/ under ground cable alongwith necessary T&P, safety devices etc. as per site requirement complete all as specified and as directed for the following:- 202 M&L for jointing of LT/ HT OH line in case of breaking of conductor and refreshing of wornout jumper by suitable jumper/ binding materials complete all as specified and directed. 203 Disconnecting worn out under ground cable from over head conductor, cutting down worn out portion of under ground cable of any type and size for repairs and taking out under ground cable loop from ground by excavating and all neccessary earth work and making fresh connection for restoration of electric supply complete all as specified. Note: Excavation, earth work, taking out cable protection covers, & sand cushion and relaying the same shall be deemed incldued in the rate quoted by contractor 204 Disconnecting worn out under ground cable of any type and size from main switch board/ any type of switch gear system including change over switch etc. for repair and taking out under ground cable loop from ground by excavating and all necessary earth work and making fresh connection by proving suitable size of lugs for restoring of electric supply complete all as specified. Note: Jointing material, Lugs etc and Excavation, earth work, taking out cable protection covers, & sand cushion and relaying the same shall be deemed included in the rate quoted by contractor 205 M&L for ACSR conductor in OH lines of HT/ LT/ street light conductor (Squirrel/ Weasel) including jumper and binding material with aluminium wire complete all as specified and directed. 206 M&L for cradle guard, hexagonal/ rectangular or as per existing shape fabricated with galvanised steel wire 4 mm dia including binding the gaurds with cradle supproting GI wire inclduing taking down existing unsv gaurd wire complete all as specified and as directed. 207 M&L for trimming of tree branches around HT / LT overhead lines including cutting and removing any foreign material like bushes or shurbs complete and removing the trimmed/ cut down branches/ bushes/ shrubs and depositing where directed at a distance not less than 100m complete all as specified and as directed.Note:- (a) The item will be measured in span length. The approx span length is 35M to 50M. (b) The cost for T&P and transportation required shall be deemed included in the rate quoted by contractor. 208 Supply and replace PVC spacers suitable for 2 wire sagged ACSR conductor complete all as specified and as directed. 209 Supply and replace PVC spacers suitable for 4 wire sagged ACSR conductor complete all as specified and as directed. 210 M&L for Pin type, porcelain, vitreous, white, brown or green insulators including one galvanised mild steel spindle, two galvanized iron washers and one galvanized iron nut, 100 mm height, 65mm dia for 1100 volts grade complete all as specified and as directed. 211 All as peritem no. 88 but height 150mm, dia 150 mmm for 11000 volts grade complete all as specified and directed. 212 M&L for shackletype, porcelain, vitreous, white, brown or green insulator includinggalvanised mild steel straps,washers, insulator bolts andnuts, of size 100 mm height, 115mm dia for 1100 volts grade complete all as specified and as directed. 213 All as peritem no. 193 above but size 150mm height,and dia 150 mm for 11000 volts grade complete all as specified and directed. 214 S/F in repairs, 1100 volts grade heavy duty PVC sheathed stranded Aluminium conductor twin core cable flat or circular of size 6 Sqmm complete all as specified and directed. 215 All as per item No 195 above but 10 Sqmm size complete all as specified and directed. 216 M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shapes or size including painted with two coats of silver aluminium paint over one coat of red oxide primer complete all as specified and as directed. 217 Scraping, cleaning and preparation of old surfaces of steel tubular pole (9 Mtr long) steel fitting complete and M&L for painting with one coat for aluminium paint after preparation of the steel surfaces and then applied strap with two coats black & white paint in strap alternatively all round the poles from the bottom of the pole for indication of the poles. Height of the strap shall be 30cm and number of strap shall be 05 Nos and all as directed by Eng-in-Charge 218 S & F in repair MCB SP 6 to 32 A, AC, 240V, 10 KA, ISI marked, either B series or C series, complete all as specified and directed. 219 S & F in repair isolator DP 40 A, AC, 240V, 10 KA, ISI Marked complete all as specified and directed. 220 S & F in repair isolator 4P 63 A, AC, 415V, 10 KA, ISI Marked complete all as specified and directed. 221 Supplying, installing, commissioing and testing of LT switchgear panel board ( Kiosk) of size not less than 600mmx600mmx500mm,IP-55 (outdoor type) , 415 Volts, 50 Hz, AC supply, three phase and neutral ( 4 wire) ,200 Amps coloured horizontal tinned Aluminium bus bars , factory made out of 3.15mm thick MS sheetstructure mounted onrigid mild steel angle iron frame of 50mmx50mmx6mm with 400mm long extended legs grouting in PCC 1:2:4 type B1 of size 150mmx150mmx250mm , duly epoxy powder coated internally and externally with approved shade, rubber gasketted, hinged front double doorand back openable doors with proper locking arrangements for dust and vermin proof ,complete including adjustable thermal and fixed magnetic release MCCB 4 pole, 100 Amps, 415V,36 KA,50 hz-01 No (incoming),suitable size cable allay,lugs , glands and making connections/ wiring with suitable size SC PVC insulated copper conductor cableall as specified. 222 Earthing complete with galvanised MS earth plate of size 600 x 600 x 6mm thick burried directly in ground not less than 2.25 Mtr below ground level, earth plate paced on all side with charcoal mixed with salt to a thickness of 150mm in layers, connected by GI earth strip of size 32 x 6mm thick, soldered and revetted to earth plate. GI earth strip will be protected by using 40mm bore GI pipe (light grade) from test point to main board. The earthing includes PCC pit chamber, RCC pit cover and frame, watering pipe 20mm bore, funnel with wire mesh with necessary earth work including disposal of surplus soil to a distance not less than 50 Mtr etc complete all as specified and shown in electrical plate No 3 of SSR Part-I. (Note : Main earth lead beyond 7.5 metre measured and paid for separately). 223 Earthing complete with galvanised MS earth plate of size 600 x 600 x 6mm thick burried directly in ground not less than 2.25 Mtr below ground level, earth plate paced on all side with charcoal mixed with salt to a thickness of 150mm in layers, connected, soldered and revetted to earth plated / galvanised earth lead wire 4.0mm dia by means of bolts, nuts , check nuts and washers of galvanised iron or steel. GI earth wire will be protected by using 15mm bore GI pipe (light grade) from test point to main board. The earthing includes PCC pit chamber, RCC pit cover and frame, watering pipe 20mm bore, funnel with wire mess with necessary earth work including disposal of surplus soil to a distance not less than 50 Mtr etc complete all as specified and shown in electrical plate No 3 of SSR Part-I. (Note : Main earth lead beyond 7.5 metre measured and paid for separately). 224 Apply proper electric shutdown of the feeder, dismantle and taking down LED street / Security light fitting of any make or modelalongwith connecting cable from elevated height of pole or building for repair by changing LED drive of suitable capacity, thorough cleaning and refixing the same after necessary repairs on its own position connecting complete all as directed. Note:- Spares of security/street light fitting shall be measured and paid under relevent supply only items. Required T & P and labour is deemed to be included in the rate quoted. 225 Supply only LED Driver suitable for any make or model LED street / security light fitting of capacity 25to 35 Watts complete all as specified and directed. 226 All as per item No 206 above but for 36 to 45 Watts complete all as specified and directed. 227 All as per item No 206 above but for 60/72 Watts complete all as specified and directed. 228 Supply only PVC sheathed two core 2.50 Sqmm stranded Aluminium conductor cable flat or round complete all as specified and directed. 229 Supply and fix 35 watts , 230V AC outdoor type (IP-65/66 protection) LED integrated street/security light fitting with all accessories incl connections and testing complete all as specified and directed. 230 All as per item No 210 above but 70 watts LED fitting complete all as specified and directed. 231 Lowering of high mast light assembly from upto 16 Mtr high mast, any make / model, dismantling, checking the serviceability and make the light fittings operational to give rated illumination incl cleaning the glass cover and refixing the same after repair / replacement of defective components complete with necessary electrical connection incl provision of two core 2.5 Sqmm PVC cable with multi stranded Copper conductor of required length, testingcomplete all as directed. Note: Flood light fitting shall be measured and paid separatelyunder relevent item. The cost of greasing of pully, roller, bearing and gear incl refixing of rope clamps , adjustment of lock, leaver, requried T & P and labour etc is deemed to be included in the quoted rate 232 Supply only LED flood light 120 watt, 230V, AC out door type with IP-66 protection with impact and corrosion resistant complete with driver complete all as specified and directed. 233 S&F LED post top light fitting IP 65 rated 20watt to light up parks, gardens and heritage sites complete all as specified and directed. 234 S&F LED bollard pressure diecast powder coated housing with PC diffuser, efficient high output LED 10 wattwith IP 65 protection complete all as specified and directed. 235 S& F in repairs and connect of solar LED street light fittings 20 watt with 40 AH battery bank, PV solar panel fitted on and incl 5 mtr steel pole with base plate incl foundation bolts, braket, clamps , nuts etc complete all as specified and directed. Note- Necesssary excavation/earth work , PCC/RCC work will be measuered and paid under relevant item of schedule. 236 Taking down unsv street light loop-in and loop out box by disconnecting electrical connection and removing existing clamps, nuts, bolts, and washers and supply, fix and connect, factory made out door type syntex street light loop-in and loop out box comprising with suitable size of bus bar, insulators, connectors etc and with one C curve 6 Amp MCB SP, one PVC way connector etc. incl suitable size clamps, nuts, bolts & washers complete all as specified and directed. 237 S&F 3 core , strandedcopper conductor cable 1.5 sqmm, PVC insulated and PVC sheathed , 1100 Volts grade for making connections from junction box tostreet light fittings including PVC conduit of size 20mm dia including necessary clampscomplete all as specified and directed. 238 S/F and connect, factory made duly painted metallic weather proof enclosure street light panel timer unit outdoor type having one 40 Amps C curve MCB TPN, three phase 415 V 32 Amps power contactor, Automatic operation street light timing switch having lighting control (ON-OFF) through Astronomical Calculation of Sun rise / sun set by setting date, time and degree of longitude and latitude without separate light sensors etc. including necessary fixing arrangements, suitable size clamps, nuts, bolts & washers complete all as specified and directed.
Contract Date : 29 Jan, 2026   |   Contract Value : 33.87 Lakhs
Disclaimer

We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.

Tender Detail
Website https://etender.cpwd.gov.in/login.html
Quantity 0
MSME Exemption No
Tender Type Open Tender
Startup Exemption Click Here
Competitive Bidding NCB
Similar Tenders
TENDER INSIGHTS

858

Electric Tenders
Live
CLICK TO KNOW MAXIMUM WIN

Tell us about your Product / Services,

We will Find Tenders for you

🇮🇳 +91
TenderDetail
Loading tenders