TDR : 56334029
Central Public Works Department

Tender Brief :

Delhi, Delhi

RMO E&M Services At Sankhyiki Bhawan In CBD Shahdara, Delhi. (SH: SITC Of Automatic Voltage Regulator For Lifts At Sankhyiki Bhawan.

Published: 06 Jul 2026
Opening: 13 Jul 2026
Closing: 13 Jul 2026
Amount: 9.46 Lakhs
EMD: 18940
Tender Fee: Ref. Documents


Works Amplifiers Supply Attenuators Bipolar Junction Transistors Capacitor Bank Cathode Ray Tubes
1
Days Left
Tender Summary / Eligibility Criteria
RMO E&M Services At Sankhyiki Bhawan In CBD Shahdara, Delhi. (SH: SITC Of Automatic Voltage Regulator For Lifts At Sankhyiki Bhawan.
Documents Download All
b0855b5e-f5b2-477b-99e3-a51636d02fef
b0855b5e-f5b2-477b-99e3-a51636d02fef.html
DocumentsList
DocumentsList.zip
No Boq
No Corrigendum
Probable Bidders

AI engine predicts probable bidders to help you bid strategically.

MSME Exception
Explore More →
Technical
Tender involves procurement of high capacity electrical equipment including diaphragm coupling of pump & motor with 90kW capacity at 2900 RPM. The project scope includes installation, testing, commissioning and operational handover.
Previous / Similar Result
BRR : 10215372 Tender For Supply Installation Testing Commissioning Of Miscellaneous Electrical Items At Meditation Centre, Rajpur Road, Delhi.--- 1 Sh: - I ( Ei Work ) Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. A ) Group C 2 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. I ) 3 X 4 Sq. Mm 3 6 X 4 Sq. Mm 4 3 X 6 Sq. Mm 5 Supplying And Fixing Of Following Sizes Of Steel Conduit Along With Accessories In Surface / Recess Including Painting In Case Of Surface Conduit, Or Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. I ) A ) 20 Mm 6 B ) 25 Mm 7 Supplying And Fixing Following Size / Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required. A ) 1 Or 2 Module ( 75 Mmx75 Mm ) 8 B ) 3 Module ( 100 Mmx75 Mm ) 9 C ) 12 Module ( 200Mmx150mm ) 10 Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. A ) 5 / 6 A Switch 11 B ) 15 / 16 A Switch 12 C ) 3 Pin 5 / 6 A Socket Outlet 13 D ) 6 Pin 15 / 16 A Socket Outlet 14 Sitc Of 34 To 36 Watt 600Mm X 600Mm Nominal Size Ledrecess / Surface Mounted Fitting Suitable For Operation At 150 To 270Volt, 50 Hz + / - 5% Frequency, ( 6000K ) , Crca Sheet Duly Power Coated / Aluminium Body, Power Factor > 0.95Luminaries Efficiency = 100 Lumen / Watt , Driver Efficiency > 85%, Ip-20 Class Protection, 2.5 Kv Surge Protection, L-70 Life 50.000Minimum Burning Hours, Complete With Electronic Driver In The Existing False Ceiling With The Help Of Suitable Chain & Wiringwith 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable I / C Dismantling Of Existing Fittings If Reqd I / C Connection, Testing Etc Complete As Reqd At Site. 15 S.I.T.C Of Surface / Wall Mounted ( Integrated Type ) 18To20 W Led Batten Fitting 1200 Mm Long ( N / S ) Made Out Ofcrca Sheet Duly Power Coated / Aluminum Extruded Body Confirming To Ip - 20, Suitable For Operation On 150 V To 270 V, 50 Hz Ac Supply, Having Power Factor = 0.90, Cri = 80, Luminaries Efficacy = 100 Lumen / Watt , Driver Efficiency > 85%, 2.5 Kv Surge Protection, L-70 Life, 50, 000 Burning Hours. Complete I / C Dismantling Of Existing Fitting, Connection, Etc. Complete As Reqd. 16 Supplying And Fixing Of1200 Mm Sweep Ac Ceiling Fan With Three Star Rating And Above Complete With All Accessories But Without Regulator I / C Wiring The Down Rod Of Standard Length ( Upto 30 Cm ) With 1.5 Sq Mm Frls Pvc Insulated Copper Conductor Cable I / C Dismantling The Existing Non Working Fan Etc. Complete As Required. 17 Sitc Of 2.0 / 2.2 Tr 3-Star Inverter Split Ac Unit With Outdoor Stand Dully Powder Coatedsuitable For Operation On 220V + 10% Single Phase 50 Hz Hv Ac Supply Complete With Energy Efficient Rotary Compressor Type Of Refrigerant R32 / 410, Copper Condenser Ref. Pipe, Indoor & Outdoor Unit, Complete In All Respect & With Cordless Remote I / C Connection Etc. As Required. 18 Supplying, Installation, Testing And Commissioning Of 5 Kva, Copper Wounded, Wall Mounted Voltage Stabilizer With Led Display, Surge Indicator, Automatic Reset Suitable For Operation On 220V + 10% Single Face 50Hz, Hv, Ac Complete Etc. As Required. 19 Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 20 Providing And Fixing Of Oil Type Room Heater Of Capacity 2400 Watt 9 Fins Suitable For Operation On 220 V, Ac 50Hz Single Phase Supply With Following Parameters:- 1 ) Adjustable Thermostat2 ) Power Indicator Light3 ) Tip Over Switch4 ) Over Heating Protection5 ) Castor Wheels6 ) With Integrated Handle 21 Supplying, Installation, Testing And Commissioning Of Convection Type Microwave Oven 28 Ltr, 1500 Watts Suitable For 230 V , 50 Hz, 1Ph With Power Defrost , Preheat, Eco Mode, Auto Programs Etc Complete As Required. 22 Supplying, Installation, Testing And Commissioning Ofdomestic Refrigerator Of Capacity 95 Ltr Suitable For 230 V , 50 Hz, 1Ph Ac Supply Having Single Door Etc Complete As Required. 23 Supplying, Installation, Testing And Commissioning Of Water Cooler With Inbuilt Purifier Of Storage Capacity Not Less Than 80 L With Cooling Capacity Not Less Than 60 L / Hr Made Up Of Stainless Steel Suitable For 230 V, 50 Hz, 1 Ph Ac Supply With 3 Stage Filtration With Working On R 22 Refrigerant Etc. Complete As Required. ( Blue Star Model No. Swcsdlx600uvroe / Kent / Ion Exchange ) 24 Supplying, Installation, Testing And Commissioning Of Water Dispenser With Cooling Cabinet Of Capacity Not Less Than 3.2 L Made Up Of Plastic Suitable For 230 V, 50 Hz, 1 Ph Ac Supply Etc. Complete As Required. 25 Supply, Installation, Testing And Commissioning Of Commercial Airpurifier For 350 Sq.Ft Area That Keeps Indoor Air Free From Dust ( Pm 2.5 & Pm 10 ) , Gases, Smoke, Odor Forming Compounds, Allergens And Air Borne Infectants. It Should Have Minimum 7 Stage Air Purification Having 5 Kinds Of Filtration Technologies Incorporating Pre-Filter, Anti Bacterial Filter, Hepa Filter And Activated Carbon Filter, Photo Catalytic Filter, Uv & Ionization. It Should Have Quite Ac Motor, Air Quality Sensor With Led Display, Filter Change Indicator, Full Feature Remote Control To Switch Between Modes And Smart Feather Touch Operational Panel Etc. As Required. 26 Sitc Of Gsm + 2G / 3G / 4G , 5V Dc Signal Booster With Two Indoor Panel Antenna, Ac Adapter, Having Frequency Band 900+1800+2100 Mhz, Output Power 23Dbm, Gain > 65Dbi, Scope To Connect Four Indoor Panel Antenna, Minimum Area Coverage 2500Sqft, System Must Be Non Hazardious And Contractor Must Place A Certificate For It Including Demo At Site Etc As Required. 27 Supplying And Laying Of Network Booster Antenna Rg-11 Coaxial Cable On Wall / Surface / Pipe / Channel Suitable For Frequency Band 800-2500 Mhz And Having Vswr < 1.5, Input Impedance 50 Ohm, Gain 12 Dbi Including N Male Connectors And Bullets Etc As Required. 28 Supply And Fixing Of Additional Panel Antenna And Splitter Suitable For Above Signal Booster I / C Testing And Commissioning Etc As Required. 29 Sitc Of Gsm + 2G / 3G / 4G Outdoor Banana Antenna, Having Frequency Band 900+1800+2100 Mhz System Must Be Non Hazardious And Contractor Must Place A Certificate For It Including Proper Fixing Of Antenna On Terrace Demo At Site Etc. As Required. 30 Sh: - Ii ( Cctv Work ) S / I / T / C Of 2Mp Dome Camera, With Poe Support, 1 / 2.8-Inch , Imager Type Cmos , Resolution 1920 X 1080 , H.265, White Balance Range: 2, 000° To 10, 000°K; Auto, And Manual, 3D Noise Reduction Yes ( On / Off Selectable ) , Lens 2.8-12 Mm , Minimum Illumination Sensitivity F / 1.4, Color 0.0169 Lux 0.00416 Lux , Mono 0.01 Lux 0.0025 Lux, Mono ( Ir On ) 0.0 Lux , Day / Night Capabilities Mechanical Ir Cut Filter ( On / Off / Auto ) , Ir Range Minimum 20 Mtr ; Auto On In Night Mode, Or Off, Signal To Noise Ratio =50 Db, Lens Type Built-In; Auto Iris Type Dc, Aspect Ratio 4:3, Frame Rates Images Per Second ( Ips ) 25, Video Encoding H.265, H.264 High , Network Port Rj-45 Connector For 10 / 100 Base- Tx, Operating Humidity 5% To 95% , Storage Humidity 20% To 80%, Impact Resistance Ik10 , Ip66 , Certifications Ce, Fcc, Ul / , Bis Etc. As Required. 31 S / I / T / C Of 2Mp Bullet Camera , With Poe Support, 1 / 2.8-Inch , Imager Type Cmos, Resolution 1920 X 1080, Ir Range Minimum 20 Mtr , Testable, Electronic Shutter Range 1 / 10, 000 Sec ~ 1 Sec , 3D Noise Reduction Yes ( On / Off Selectable ) , Signal To Noise Ratio =50 Db , Mechanical Ir Cut Filter ( On / Off / Auto ) , Lens Type Built-In; , Focal Length 2.8 ~ 12 Mm , Frame Rates 25, Video Encoding H.265, H.264 High, Network Port Rj-45 Connector For 10 / 100Base-Tx , Ip66 / 67 , Onvif Profile S, Profile G, Profile Q, And Profile T , Supported Protocols Tcp / Ip, Udp / Ip ( Unicast, Multicast Igmp ) , Operating Humidity 5% To 95% , Storage Humidity 20% To 80%, Impact Resistance Ik10, Ip66, Certifications Ce, Fcc, Ul / , Bis Etc As Required. 32 Supply, Installation , Testing &Commissioning Of Up To 8 Channelnvr System Ip Camera Input / H.265 / H.264 Dual Codec Decoding Support 4K Resolution Upto 4Mp Recording / 160Mbps Incoming And 320Mbps Outgoing Bandwidth / Support 2 Sata Hdds Up To 12Tb, 1 Usb Ports / Hdmi / Vga Simultaneous Video Output / Support Multi-Brand Network Cameras 33 Supplying & Fixing Of 8 Port Layer 2, 10 / 100 / 1000 Elthernet Ports, 2 Gigabit Small Form Santic Pluggable ( Sfp ) Module Uplink Slots Poe Budget Of Upto120 Watt Of Complete, Testing As Required. 34 Sitc Of 6Tb Cctv Hdd. This Enterprise Hard Disk Specially Designed For 24*7 For 30 Days Etc. Complete As Required. 35 Sitc Of32 Inchesfollowing Sizes ( Screen Size ) Fhd Led Tv, Full Hd 1920 X 1080 Pixels With Inbuilt Speaker Of 20 Watt ( Record, Pause, Rewinding, Live Shows ) , Connectivity 2 Hdmi Port & 1 Usb Port, With Complete All Accessories Etc. As Reqd. 36 Sitc Of Full Hd Professinal 55 Diagonal Size, 60Hz Led Blu Type Technology, 1920X1080 ( 16:9 ) Resolution , 330Nit Brightness , Rgb Inputs Of Analog D-Sub, Dvi-D, , Video I / P Of Cvbs Component, Hdmi, And Audio I / P Of Stereo Mini Jack, Power Supply Ac 100 - 240 V~ ( + / - 10 % ) , 50 / 60 Hz, Etc With Mounting Accessories Etc As Required. 37 Supplying Fixing Of 24 Port Fully Loaded Jack Panel For The Network Switchetc As Req. 38 Supplying And Fixing Of 1 Mtr Cat-6 Patch Cord In Cctv Camera And Newtork Complete As Required. 39 Supplying And Fixing 9U Wall Mounted Powder Coated Crca Sheet Made, Networking Rack With Lockable Front Glass Complete As Required. 40 Supplying And Drawing Of4 Pair Cat 6 Lan Cable On The Existing Surface / Pvc Conduit As Required. ( I ) 1 Run Of Cable 41 Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. ( I ) 25Mm
Contract Date : Ref. Documents   |   Contract Value : Ref. Documents
BRR : 8660668 Tender For Construction Of State Tax Office Building At Gauripur Checkpost District Baghpat - Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), includingdressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2 In all kind of soil upto 1.5m depth R.W 3 In all kind of soil upto 1.5m to 3.0m. depth 4 In all kind of soil upto 1.5m to 3.0m. Depth R.W 5 In all kind of soil upto 3.0m to 4.5m. depth 6 In all kind of soil upto 3.0m to 4.5m. Depth R.W 7 In all kind of soil4.5m to above . Depth R.W 8 Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift 9 Providing and laying in position cement concrete of specified grade excluding the cost ofcentering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) ,including cost of form- work,in foundation and floors. 10 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 11 Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mmapart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor With Chlorpyriphos/Lindane E.C. 20% with 1% concentration 12 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) in R.C.C. Raft foundation and footing with approved stoneballast. (Using1:1.5:3Mix concrete)M-20 13 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) foundation 14 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement -1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) All work up to plinth level : 15 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). [FOR SLAB] 16 R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit in the proportion of 1:1.5:3 in Slab and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20.R.W 17 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). [FOR BEAM] 18 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). [FOR COLUMN] 19 Reinforced cement concrete work in arches, archribs, domes, vaults, shells, folded plate and roofs having slope more than 15° up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).[FOR arches, archribs, domes] 20 Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete in mouldings as in cornices, windows sills etc, including setting in cement mortar 1:3 (1 cement : 3 coarse sand) cost of required centering, shuttering but, excluding the cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarsesand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 21 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in.foundation and plinth in :Cement mortar 1:6 (1 cement : 6 coarse sand) 22 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in.foundation and plinth in :Cement mortar 1:4 (1 cement : 4 coarse sand) 23 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 24 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) 25 Same as in item no. 11 but in1:4 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work. 26 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface beforetreatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making patternof 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : 22.7.1 With average thickness of 120 mm and minimum thickness at khurra as 65 mm. 27 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 28 15 mm cement plaster on rough side of single or half brick wall of mix:1:4 (1 cement: 4 coarse sand) [Plinth Plaster] 29 15 mm cement plaster on rough side of single or half brick wall of mix:1:6 (1 cement: 6 coarse sand) 30 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) 31 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) DRAIN 32 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the costof nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate 33 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the approved make & colours) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm 34 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigments etc., complete. 35 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 36 Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 37 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade. New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm).warehouse 38 Finishing wall with water proof cement paint of approved make and quality on new wood with two coat to give an even shade including supply of all materials, labour, tools and plant etc. required for proper completion of the work. (Two Coat) 39 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour. New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre(For Internal wall surface) 40 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 41 Making grooves 12mmwide x12mm deep in plaster of the walls or in ceiling vertically or horizontally as required 42 Making of draing along with apron 150 X 150 MM 43 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 44 Supply and fixing of flush Doors commercial quality conforming to I.S. 2202 Part 1 (1983) including fixing of wooden cleats and stoppers and including fixing and adjustment of hinges bolts locks handles springs fitting with necessary screws to be supplied 35 mm thick single leaves 45 Providing and fixing SS sliding door bolts ISI marked anodised transparent or dyed to required colour or shade with nuts and screws etc. complete : 250x16 mm. 46 Providing and fixing SS tower bolts ISI marked anodised transparent or dyed to required colour or shade with necessary screws etc. complete : 250x10 mm. 47 Providing and fixing SS handles ISI marked anodised transparent or dyed to required colour or shade with necessary screws etc. complete :125 mm. 48 Providing wood work in frames of doors, windows, clerestory windows and other frames,wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). (SAL WOOD) 49 12 mm thick one side Pre-laminated particle board (decorative lamination on one side) for Door Chaukhat Paneling 50 Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.(Second class teak wood) 51 Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges andscrews and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 52 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works(GATE)/OHT 53 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 54 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required diaand size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : (Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) 55 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) 56 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 57 (Fixing of Door, windows/ventilators chaukhats in position. Door 58 (b) Windows 59 (c) Clerestory window chowkhats 60 Float glass panes (4 mm thick glass pane (weight not less than 10kg/sqm). 61 Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc.Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.Threetrackthreepanelsslidingwindowwithtwoglazed &onewiremeshpanelswithAluminiumchannelforroller track,woolpile,nylonrollerswithSS304body. UsingR3serieswithframe(98mm&above)x (40mm&above)&bothglazedandflyscreen sash(30mm&above)x(55mm&above) withzincalloy(Zamak)powdercoatedhandle oneveryglazedpanelalongwithmulti-point lockingsystem.(Heightupto1.8m). 62 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangementsfor inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.20 mm M.S. laths with 1.20 mm thick top cover 63 Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture GATE 64 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 65 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes (weights not less than 10 kg/ sqm). 66 Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. 67 Providing & fixingAluminiumsliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 300mm x 16mm. 68 Providing and fixingAluminium. anodised towerbolts (barrel type) with necessary screws etc. complete. 250 mm x 10mm 69 (a) 200 mm x 10mm 70 Providing and fixinganodised handles with screws etc. complete (a) 125 mm. 71 Foundations, footings, bases of columns, etc. for mass concrete 72 Suspended floors, roofs, landings, balconies and access platform 73 Lintels, beams, plinth beams, girders, bressumers andcantilevers 74 Columns, Pillars, Piers, Abutments, Posts and Struts 75 Columns, Pillars, Piers, Abutments, Posts and Struts 76 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 77 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 78 Chequered terrazo tiles 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) : Light shade pigment using white cement 79 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). 80 Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer 81 Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance ≥ 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizont al level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out asper specifications, drawings and as per directions of the engineer-in-charge.With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.60) 82 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish oftapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer’s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks) 83 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 84 Direction & Place identification Signs more then .90sqm size BordP/Erectung direction & Place identification retro-reflectorised sign as per IRC-67 made of high intensity grade sheeting the retro-reflective sheeting type-IV shall be lested for 3 year outdoor weathering. 85 Providing, fabricating and fixing/ erection of 4-5mm SS plate in approved shade at desired location as per approved drawing of SALE TAX OFFICE BUILDING GAURIPUR BAGPAT having Helvetica Font with 75 mm size Also including cost of providing and fixing of fasteners complete in all respects as per Engineer in charge 86 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller8 including making good the undulations etc. and re-rolling the subWC .g rade and disposal of surplus earthwith lead upto 50 metres. (DSR-16.1) 87 Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineerin-chargeCement concrete manufactured in automatic batching plant (RMC plant) including transportation to site in transit mixer. (DSR 16.43.2) 88 Providing and laying in position bitumen hot sealing compound for expansion joints etc. Using grade A sealing compound. (DSR- 16.46.1) 89 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge 90 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by usingplate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-inCharge. 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern 91 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 92 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid 93 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked black solid plastic seat and lid 94 Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/6 litre (adjustable to 4 litre/8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. 95 Providingandfixing wash basin with C.I.brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting andmaking good the walls where required : White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap 96 Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15mmbrass pillar taps, brass chain with rubber plug, 32mmbrass waste of standard pattern including cutting & making good the walls wherever required.a)White Vitreous China Wash basin size 630x450 mmwith a pair of 15 mm C.P. brass pillar taps 97 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern. 98 Range of two urinal basins with 5 litre white P.V.C. automatic flushing cistern 99 Range of three urinal basins with 10litre white P.V.C. automatic flushing cistern 100 Range of four urinal basins with 10litre white P.V.C. automatic flushing cistern 101 Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge 102 Providing & fixing stone slab table rubbed, edges rounded and polished of size 75 X 50cm deep and 1.8 cm thick fixed in urinal patitions by cutting chase of appropriate width with chase cutter and embedding the stone in chase with epoxy grout or with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregste 6mm nominal size) as per Engineer-in-charge and finished smooth Granite stone of approved shade 103 Providing and fixing Salem Stainless Steel A ISI 304 (18/8) kitchen sink as per IS: 13983 with CI brackets and stainless steel waste with plug 40mm including painting of fittings and brackets, cutting and making good the walls wherever required. Kitchen sink without drain board 510x1040 mm bowl depth 250 mm 104 Providing & fixing PVC waste pipe for sink oncluding PVC waste fitting CompleteFlexible Pipe 32mm Dia 105 40mm Dia 106 Bottle trap 31 mm single piece moulded with height of 270 mm, effProviding and fixing PTMT Bottle Trap for Wash basin and sink. ective length of tail pipe 260 mm from the centre of the waste coupling 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms. 107 Bottle trap 38 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms.(sink & urinal) 108 Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 1500x450 mm 109 Providing & fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestos cement sheet ground fixed to wooden cleats with C.P. brass screws and washers. 110 Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. 111 Providing and fixing toilet paper holder :C.P. brass 112 Providing and fixing soil, waste, vent pipesCentrifugally cast (spun) iron S&S pipe 100mm dia cast (spun) iron S&S pipe 113 Providing and fixing MS holder bat clamps of approved design to cast iron (spun) pipe embedded in and Including cement concrete blocks 10 x10 x10cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls etc. For 100mm dia. Pipe 114 Providing and fixing heel rest sanitary bend, in Centrifugally cast (spun) iron pipe S&S 100mm 115 Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete.100X100X100mm Sand cast iron S&S as per IS : 3989 116 Providing and fixingPLAIN JUNCTIONof required degree 100X100X100mm Sand cast iron S&S as per IS : 3989 117 Providing and fixing terminal guard: 100mm Sand cast iron S&S as per IS - 3989 118 Providing and fixing collar. 100 mm Sand cast iron S&S as per IS - 3989 119 Providing and lead caulked joint 100 Dia 120 Providing and fixingcast iron trap of self cleansing design withcast iron screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors.100 mm inlet and 100 mm outlet,Sand cast iron S&S as per IS: 3989 121 Painting sand cast iron / centrifugally cast iron( spun) iron soil, waste and vent pipes and fittings with paint of any colour such as chocolate, grey or buff etc. over a coat of primer (of approval quality) for new work100mm dia 122 Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour weighing not less than 105 gms. 123 Providing & fixingPTMT towel ring trapezoidal shape 215 mm long 200 mm wide with minimum distance of 37 mm from wall face with concealedfittings arrangement of approved quality and colour weighing not less than 88 gms 124 Providing and fixing PTMT towel rail complete with brackets fixed wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. 125 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.Internal work - Exposed on wall 15 mm nominal outer dia pipes 126 20 mm nominal outer dia pipes 127 25 mm nominal outer dia pipes 128 32 mm nominal outer dia pipes 129 Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall 15 mm nominal outer dia pipes 130 20 mm nominal outer dia pipes 131 Providing and fixing G.I. pipes complete with GI fittings and clamps including cutting and making good the walls etc. External work25 mm dia, nominal bore 132 40 mm dia, nominal bore 133 40 mm dia, nominal boreOHT 134 50 mm dia, nominal bore 135 65 mm dia, nominal bore 136 Providing and fixing of gun metal gate valve with CI wheel of approved quality (screwed ends)25mm dia, nominal bore 137 32 mm dia, nominal bore 138 40 mm dia, nominal bore 139 65 mm dia, nominal bore 140 Providing and fixing uplasticised PVC connection pipe with brass unions :45 cm length15 mm nominal bore 141 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet100 mm diameter Providing and fixing brass stop cock of approved quality : 142 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 143 Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work (internal work -exposed on walls)15 mm nominal outer dia pipes 144 20 mm nominal outer dia pipes 145 25 mm nominal outer dia pipes 146 32 mm nominal outer dia pipes 147 40 mm nominal outer dia pipes 148 65 mm nominal outer dia pipes 149 Painting GI pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality25 mm dia, nominal bore 150 40 mm dia, nominal bore 151 50 mm dia, nominal bore 152 65 mm dia, nominal bore 153 Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work 25 mm dia, nominal bore 154 40 mm dia, nominal bore 155 50 mm dia, nominal bore 156 65 mm dia, nominal bore 157 Providing and fixingG.I. union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (new work)15mm nominal bore 158 20mm nominal bore 159 25mm nominal bore 160 Providing and fixing C.P. brass bib cock of approved quality confirming to IS:8931 15mm nominal bore 161 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15mm nominal bore 162 Providing and fixing C.P.brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 a) 15 mm nominal bore. 15 mm nominal bore 163 Providing and fixing PTMT grating of approved quality and colour Circular type 100 mm nominal dia 164 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank 165 Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth including consolidating each deposited layers by ramming, watering etc. stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50m : Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia. 166 Providing, laying and jointing glazed stoneware pipes grade ‘A’ with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete150 mm diameter 167 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design :150 mm diameter S.W. pipe 168 Providing and fixing square-mouth S.W. gully trap grade A’ complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than100x100 mm size P type 169 150x100 mm size P type 170 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :250 mm dia rcc pipe 171 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 gradeInside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : 172 Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 173 Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : 174 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 MM 175 75 MM 176 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes. 110 mm 177 75 mm dia 178 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming toIS : 5382, leaving 10 mm gap for thermal expansion.Coupler110 mm 179 Bend 87.5°110 mm bend 180 75 mm bend 181 Shoe plain 110 mm bend 182 75 mm bend 183 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 184 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 185 Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design :With 20x20 mm square bar 186 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design. With F.P.S. bricks 187 Providing and fixing C.I. tee at the inlet and outlet of septic tank. 188 Providing & fixing 75mm dia vent pipes. 189 Providing & fixing of 75mm dia cast iron terminal guard. 190 Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. 191 H.D. -20- Circular shape 560mm internal diameter 192 M.D. -2.5- Circular shape 450mm internal diameter 193 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 194 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 195 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 196 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 197 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 198 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 199 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 200 4 X 6 sq. mm + 2 X 6 sq. mm earth wire 201 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 202 Wiring for group controlled ( looped ) light point/ fan point/ exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 203 Supplying and drawingCo axial TV cable, RG-6 grade, 0.7 mm solid copper conductor, shieldedwith fine tinned copper braid and protected with PVCsheathin the existing surface/recessed steel/PVC conduit as required. 204 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm 205 25 mm 206 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch 207 3 pin 5/6 A socket outlet 208 TV antenna socket outlet 209 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 210 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 211 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm) 212 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 213 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 214 Supplyingandfixing3pin5Aceilingroseon the existing junction box/woodedn blockincluding connectionetc. as required. 215 LayingofonenumberPVCinsulatedandPVC sheathed/XLPEpowercableof1.1KVgradeof following size direct in ground including excavation,sandcushioning,protectivecoveringand refilling the trench etc. as required. Upto 35 sq. mm 216 Supplying&makingendterminationwithbrass compressionglandandaluminiumlugsforthe following size of PVC sheathed / XLPE aluminiumconductorcableof1.1KVgradeasrequired.2 X 10 sqmm. (19mm) 217 Providing,layingandfixingfollowingdiaG.I. pipe(mediumclass)ingroundcompletewithG.I. fittings including trenching (75 cm deep) andrefilling etc as required.50 mm Dia 218 Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. 219 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep 220 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed S teel/ PVC conduit as required. 1 run of cable 221 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required. (for A.C. Point/MCB Point) 222 Supplying and fixing PVC batten/ angle holder including connections etc. as required. 223 Supplying and fixing following way, horizontal type three pole and neutral (TPN), sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)4 way (4 + 12), Double door 224 6 way (4 + 18), Double door 225 12 way Bouble door G.Room 226 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4 + 12), Double door 227 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required Single pole. 228 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 229 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100 A,30KA,FPMCCB 230 Supply and fixing of 40 Amp. FP MCB (10 KA) C Curve. CAT A 231 Supply and fixing of 63 Amp. FP MCB (10 KA) C Curve. CAT A 232 Supplying and fixing following rating, four pole, (three phase and neutral) SPN, 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 A 233 63 A 234 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 235 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 236 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 237 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 238 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.100 mm width X 50 mm depth X 1.6 mm thickness 239 300 mm width X 50 mm depth X 1.6 mm thickness 240 Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required. 100 mm dia 241 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, ), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 242 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following sizesize 25 sq mm x 3-1/2core 243 size 35 sq mm x 3-1/2core 244 size 185 sq mm x 3-1/2core 245 Supply& Erracetionof factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreise Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release) Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters (KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above insulated with heat shrink sleeving and mounted on non gyroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm.Cubicletype switchboard shall be of cat A & B Only. CAT. B Cubicle TypeIncoming -400 Amp MCCB-1 No.Outgoing - 100 Amp 4P MCCB - 3 Nos. (for VTPN D.B. DBs)63 Amp 4P MCCB - 2 Nos. (or As per requirment directed by Project Manager.) Outdoor Fidder Pillar Panel : 246 400 Amp MCCB-1 No.Outgoing - 100 Amp 4P MCCB - 3 Nos. (for VTPN D.B. DBs)63 Amp 4P MCCB - 2 Nos. (or As per requirment directed by Project Manager.) Outdoor Fidder Pillar Panel :Incoming -400 Amp MCCB-1 No.Outgoing - 200 Amp 4P MCCB - 2 Nos. 100 Amp 4P MCCB - 1 Nos.63 Amp 4P MCCB - 1 Nos. (Spare)(or As per requirment directed by Project Manager.) 247 S/F of hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16SWGM.S. sheet incorporating 10mm dia, M.S. round barduly bent for supporting fan hanger dully painted withred oxide and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting along with supply of all materials, labour T & P etc., for proper completion of work. 248 Supply & fixing of 12 Watt LED Bulb - B22 / E27 (Colour Temp.- 6500K / Lumens - 900 lm) cool day light, Input Volts (AC 90V-260V), 3-Star rating suitable for Batten/Angle holder including making connection.Complete in all respect. 249 Supply of factory made 300mm sweep ventilating (Medium Heavy Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Double ball bearing /Copper motor /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 70/85 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Speed : 900/1400 RPM. Complete in all respect. 250 Supply & fixing of 400 mm sweep wall mounted (Light Duty) fan complete with Plastic Blade & Pull Cord (Adjustable upward and downward tilt mechanism /motor /capacitor etc.) Oscillation degree - 90, Power consumption : 60 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Speed : 1350 RPM. Complete in all respect. 251 Supply and fixing of Single light Wall Bracketon matching M.D.F.E.G. Board base etc. Decorative Light with 12 W LED Bulb Complete in all respect. CAT. - AAA 252 Supply and fixing of LED Tube Light fitting suitable for up to 1X22 Watt LED Tube Light on surface complete in all Respect . 253 Supply & fixing of recess mounting round 10 to 15 watt LED down Lighter complete in all respect. 254 Supply & fixing of recess mounting round 15 to 18 watt LED down Lighter complete in all respect. 255 Supply and fixing of 1x36 to 46 Watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing body with extended heat sink and diffuser of Special Polycarbonate meterial and driver set complete in all respect CAT. - AAA 256 Supply and fixing of 1x36 to 46 Watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing body with extended heat sink and diffuser of Special Polycarbonate meterial and driver set complete in all respect CAT. - AAA 257 Supply & fixing of recess mounting round 1x6 to 8 watt LED Ceiling Lighte complete in all respect. 258 Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications.Make : Notofire/Honeywell/Tyco Two loop panel 259 Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required. Make : Notofire/Honeywell/Tyco 260 Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required.Make : Notofire/Honeywell/Tyco 261 Supplying, installation, testing & commissioning of addressable manual call point complete as required. Make : Notofire/Honeywell/Tyco 262 Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. Make : Notofire/Honeywell/Tyco 263 Supplying, installation, testing & commissioning ofaddressable horn cum strobe complete as required.Make : Notofire/Honeywell/Tyco 264 Supplying, installation, testing & commissioning ofaddressable fire control module complete as required.Make : Notofire/Honeywell/Tyco 265 Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. 266 SITC of Singal Headed Hydrant Landing Valve comprising of 80 mm dia flanged Bend 63 mm dia, with cap and chain conforming to IS:5290(Make : Kartar/Newage/Minimax) 267 SITC of RRL Hose Pipe 63 mm dia × 15 Mtr. Long with GM Coupling conforming to IS : 636(Make - Kartar/Newage/Minimax) 268 SITC of Short Branch Pipe as per IS:903(Make : Kartar/Newage/Minimax) 269 SITC of Hose Cabinet Box of 18 SWG M.S.Sheet with glass to accommodate Hose Reel Drum with Ruber Pipe with Nozzle. 2 Nos. RRL Hose and 1 No. Branch Pipe with Nozzle (750 x 600 x250 mm Size) 270 Providing and fixingMS Pipes conforming to IS:1239 (Medium- B class) including all fittings like anchor fasteners, brick masonry supports, couplings, bends, elbows, tees and flanges etc. welded or screwed joints as required, cutting holes and chases in brick or RCC walls and making good complete. (For Riser) Make : Jindal80mm dia 271 100mm dia 272 150mm dia 273 Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required . (Make : Kartar/Newage/Minimax)Single headed Gunmetal 274 Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. (Make : Kartar/Newage/Minimax) 80mm dia 275 100mm dia 276 150mm dia 277 Supply, installation, testing and commissioning of Manual Swing Type First aid Fire Hose Reel conforming to IS: 444 complete with all other necessary fixing accessories.(Make : Kartar/Newage/Minimax) 278 Supply of Fire Man Axe. 279 SITC of Air vessel made of 250 mm dia , 8 mm thick M.S. sheet, 1200 mm in height with airrelease valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shed as required. 280 Supply, Installation, Testing & Commissioning of NRV complete with flanges, gasket and nut bolts. (Make : Kartar/Newage/Minimax) 100 mm 281 SITC of Butterfly Valve complete with all respect.(Make : Kartar/Newage/Minimax) 100 mm 282 Supply, Installation, Testing & Commissioning of Pressure Gauge with gauge cock 283 Supply, fixing , testing & commissioning of electrical motor driven fire pump suitable for automatic operation consisting of following : (Terrace Pump)(Make : Kirloskar/Mather+Platt)(a) Horozontally mounted, split casing, Centrifugal fire pump complete for delivery of under mentioned discharge against desired mentioned head so as to ensure a minimum pressure of 30 meter at the highest and farthest outlet at the specified flow cmplete with necessary strainers, pressure gauge including bypass arrangement for periodic testing of the working of the pumpset with required length and size of medium class GI pipe and control valves for proper completion of work.The pump shall be capable of giving 150% of rated discharge at head not less than 65% of rated head.The pump shall be provided with Mechanical seals. The impeller shall be enclosed type and accurately blanced dynamically.The pump casing shall be of cast iron, impeller shall be of bronze and shaft shall be of stainless steel.(b) Squirrel cage, TEFC induction motor suitable for 415 V, 3 phase having IP 55 protection and class B insulation for the above pump and flexible coupling with the pump.The motor shall b rated for continuous duty and shall have HP rating necessary to drive th pump at 150% of its rated discharge at 65% of rated head.© Common bed plate of fabricated mild steel channel or cast iron type.(d) Suitable cement concrete pump foundation and vibration clamping arrangement as required with foundation bolts, anti vibration pads, washers etc.(e) Pressure switch for automatic operation of motor including necessary wiring upto control panel.(f) Electrical Control panel with starter, 3 Pole motor protection category current limiting type MCCB, indicating light, ammeter, voltmeter, selector switches, CTs protective fuses, single phasing protection, dry suction cut off etc as requrd as per standard details.Discharge :450 liter per minuteHead : 35 meter 284 Supply & fixing of fire extinguisher, ABC Type 6.00 kg. capacity(ISI Marked IS:15683 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.Make: Firejeet/Minimax 285 Supply & fixing of CO2 type fire extinguisher,6.5 kg. capacity(ISI Marked IS:2878 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.Make: Firejeet/Minimax 286 Providing and placing on terrace (at all floor levels)polyethylene water storage tank ISI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fitting and base support for tank.[Sintex, Electroplast, Star, Lotus or equivalent having valid ISI license]. Per liters capcity. 287 Supply and fixing of 16 mtr High mast Shaft of approved make with rising system, hot dip Galvanized inside & outside, having pole sheet thickness 3 mm. Top dia minimum 150 mm, bottom dia minimum 360 mm, base plate 32 mm thick suitable for wind velocity as per IS 875 part 3 &.having no circumferential weld, with accessories for high mast such as head frame suitable for 6 to 12 luminaries & its control gear boxes,1.5 HP Power tool motor, 3 point suspension system with steel wire rope 6 mm dia, double drum winch. Including making suitable Foundation as per manufacture drawing & site requirement along with foundation bolts, nuts, washers, anchor plates etc.Complete in all respect as per direction and satisfaction to the Engineer-in-charge. 288 Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with dirver set suitable for 170 to 200 Watt. Confirming to IP 66 protection complete in allrespect. complete in all respect. CAT AAA 289 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc.Following sizesize 10sq mm x 2 core 290 size 16 sq mm x 4 core 291 size 10 sq mm x 2core 292 S/F of 6mtr G.I Octagonal pole of approved make (Top dia 70 mm, Bottem dia 130 mm and Base plate 12mm thick ) having 3mm thikness with single arm bracket 1mtr length in 1:2:4 R.C.C foundationbolt including the cost of foudation ,excavation & back filling & required TNP Complete in all respect. 293 S/F of LED street light Fitting having Die cast aluminium Body & diffuser with driver set suitable for 75 to 90 watt confirriming to IP 66 & above Protection complete in all respect 294 S/F following capacity of automatic street light cubicle control panel painted with anticorrosive alkali and acid proof paint consisting of timer switch TSO 100 series with contractors HRC fuses, isolating switch Metreing instrument and instrument box with CTS etc. in case of TPN complete in all respects including the cost of fixing materials, labour T & P etc. as per direction and satisfaction to the E/I. 15 A SPN 295 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 296 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 297 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 298 Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required. 100 mm dia 299 Supply& Erracetionof factory fabricated & wired metal clad dust and vermin proof floor mounting,M.S. Channel Base with bottom and top cable entreis Electricalcontrol panel with TPN MCCBs (Four Pole 36 KA with thermal magnaticrelease)SwitchesComplete and instrumentchamber etc.complete in all respects. The instrumentchamber shall be separate and shall comprise of flushtype digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for differentreadings, instrumentfuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininumbusbars as per IS8623 or above insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable sidecovers and shall be suitable for extension on the sides. The MCCBs shallbe completewith suitablecable end boxes,compression glands and indicating lamp on incoming etc.The Job includesthe grountingof the board as per directions of Engineer-incharge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shallbe fabricatedwithCRCA sheet with a minimumthicknessof 1.6mm/2mm.Cubicletype switchboard shallbe of cat A & B Only.Incoming :100 Amp MCCB -1 No.Outgoing :63 Amp. MCCB - 1 No. & 32 Amp. MCCB-2 Nos.Cat. B. Pannel Cubicle Type 300 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-incharge, upto 90 metre depth below ground level. Drilling of 300mm dia bore hole. 301 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction ofEngineer-in-charge. 150 mm nominal size dia 302 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 303 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 304 Supplying, filling, spreading & leveling coarase sand of size range 1.5 mm to 2mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer-in-charge. 305 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/medium/coarse, in required grading & size as per actual requirement, all complete as per direction of Engineer-in-charge. 306 Constructing brick masonry INSPECTION chamber 60x60x60 cm with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand) including CI cover with frame LIGHT WEIGHT complete asperdesign. With FPS bricks60x60x60 cm inside 307 Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m.including getting out the excavated soil & then returning the soil as required,in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m.up to 1.50 m depthPipes, cables etc. exceeding 80mm dia. But not exceeding 300 mm dia. 308 Providing, laying and joining glazed stone ware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. 150mm diameter 309 Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design. 150mm diameterS.W. Pipe 310 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge. 300 dia & Upto 90 metre depth 311 300 dia & Beyond 90 metre & upto 150 metre depth 312 Supplying, assembling, lowering and fixing in vertical position in bore well,unplasticized PVC medium well casing (CM) pipe of required dia,conforming to IS: 12818, including required hire and labour charges, fittings& accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 200mm nominal size dia 313 Supplying, assembling, lowering and fixing in vertical position in bore wellunplasticized PVC medium well screen (RMS) pipes with ribs, conformingto IS: 12818, including hire & labour charges, fittings & accessories etc.all complete, for all depths, as per direction of Engineer-in-charge. 200 mm nominal size dia. 314 Providing and lowering G.I. pipes complete with G.I. fittings including trenchingand refilling etc. 65 mm dia nominal bore (Column pipe). 315 Supplying, filling, spreading & leveling pea gravel[(3.14/4)*(.3*.3-.2*.2)*140)]=5.50 316 Charges for development by 150 PSI Compressor Per Hr. 317 SITC of Pumping plant including starter, control Panal, cable, complete in all respect with all required material T&P labour etc. [7.50H.P. ] Crompton/K.S.B., Oswal make 318 Supply and wiring of 3 number 6 sq. mm. FRLSH PVC insulated 1100V grade multistrand single core copper conductor cable in 40mm dia heavy guage rigid steel conduit on surface, with two number 10 SWG copper earth continuity wire etc, complete in all respect From Transformer to Panel 319 Water Supply of tanker 5000 litre capacity of boring. 320 S/F %0 KVA DG Set
Contract Date : 09 Jan, 2026   |   Contract Value : 7.50 Crore
BRR : 9456636 Tender For Fire Alarm, Wet Riser / Hydrant And Sprinkler System At 200 Bedded Combined District Hospital, Etawah (U.P.), 1 FIRE ALARM, WET RISER / HYDRANT AND SPRINKLER SYSTEM AT 200 BEDDED COMBINED DISTRICT HOSPITAL, ETAWAH (U.P.) 2 CIVIL WORK (PUMP HOUSE & U.G.T.)- 3 Excavation in foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. From Lvl. 0.00 Mt. to 1.50 mt 4 Excavation in foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. From Lvl. 1.5 Mt. to 3.0 mt 5 Excavation in foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. From Lvl. 3.0 Mt. to 4.5 mt 6 Providing and laying in cement concrete 1:4:8 (1 cement : 4 coarse sand :8 graded Stone aggregate 40 mm nominal size) and curing complete,including cost of form- work, in foundation and floors. 7 Local Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 km. from the site of work & including watering, dressing etc. Rateinclude cost of all materials, labourand T&P etc. required for proper completion of the work. 8 Providing and injecting chemical emulsion for pre constructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete. (plinth area of the building at ground floor only shall be measured as per I.S.6313 (PartII 1981) Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1) Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm (4) Treatment junction of wall and the floor 7.5 liters /sqm (5) Treatment of soil along external perimeter of building 7.5 liters/sqm (6) Treatment of soil under apron along external perimter 5 liters/sqm. (As per manufacturers standard dilution) 9 R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not be less than M-20. (Lintel) 10 R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not be less than M-20. (Slab) 11 R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not be less than M-20. (Beam) 12 R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not be less than M-20. (Foundation) 13 R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not be less than M-20. (Column) 14 Class M-150 brick work in 1:6 cement coarse sand (of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work. 15 M-150 Brick work in super-structure (1:6 cement coarse sand above plinth level up to floor two level (up to two storeys) includingnecessarycutting and moulding of brick work asrequiredand also including honeycombed brick work in thickness of wall more than 12cms. 16 M-150 Brick work in super-structure in 1:3 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work M-150. 17 Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 18 Providing and laying brick coba 12mm thicklaid with M-150 class brick bat coba 7.50cm thick with gap of 15mm to eachother,over 20 mm thick base of cement mortar1:4cementand coarse sand mixed with water proofing compound spreading cement slurry mixed with acrelic cement concrete water proofing compound filled gaps of coba & top of coba mortar mixed with water proofing compound in 1:4 cementandcoarsesandmortar finised smooth & top mashed false square 30 cm x 30 cm and side wall parapet shall be mono tythic plaster wall up to 30 cm higher and junction and corner shall be rounded by brickballastcement and coarse sandmasonany Cobawithtop finised plaster mixed with acetic water proofing compound@ 2%byweight & including s/o all material, labour, T& P etc complete for proper completion of work. 19 Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. Providing & fixing of hold fast for chaukhatsof doors and windows. 20 Providing & fixing of door / windows grill. 21 P&F of Z-Section steel windows 22 P&F of Angle iron door chaukhats 40*40*5 23 P&F of ISMB 200 SECTION 24 Supply & fixing of flush doors commercial quality conforming to I.S. 2202 Part 1 (1983) including fixing and adjustment of hinges bolts locks handles springs fitting with necessary screws to be supplied departmentally. (a) 35mm thick 25 Providing and fixing ISI marked oxidised M.S. fittings with screws etc. complete 26 P/F FE-500 STEEL work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. 27 Fixing of Door, windows / ventilators chaukhats in position. Door chaukhats 28 Fixing of Door, windows / ventilators chaukhats in position. Window chaukhats 29 15 mm cement plaster on rough side of single or half brick wall of mix: 1:4 (1 cement: 4 coarse sand) 30 12 mm cement plaster in single coat on fair side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 course sand 31 12 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 course sand 32 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (40 mm thick floor). 33 Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (25 mm thick floor). 34 20mm thick cement plaster in dado or skirting in 1:2 consisting of one part of cement and 2 parts of approved coarse sand laid in panels, finished with 3mm floating coat of neat cement or cement and marble dust in ratio of 5:1 including supply of all materials, labour and T & P etc required for proper completion of the work. 35 Providing and fixing glass strips in joints of terrazo/ cement concrete floors 40 mm wide and 4 mm thick. 36 Painting or varnishing work in small areas or new wood work with one coat upto one square metre of ready mixed priming paint and one coat of approed superior quality ready mixed paint or varnish including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. Paint to be used should fonfirm the ISI no. 103-1950 (M.S. & wood works) 37 Distempering (Two coat) with Dry distemper of approved brand and manufacture & of required shade on ceiling to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost of all materials. 38 Finishing wall with water proof cement paint of approved make and quality on new wood with two coat to give an even shade including supply of all materials, labour, tools and plant etc. required for proper completion of the work. (Three Coat) 39 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes 40 Providing and laying water proofing treatment in underground structure by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 41 Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars. 42 560 mm diameter C.I. cover (heavy duty) the weight of the cover to be not less than 108 kg 43 PUMP HOUSE ELECTRICAL WORK- 44 Wiring points for light with 1 sqmm.FR PVC insulated multistrand single core copper condutor cable in PVC conduit pipe partly concealed in wall and partly laid in slab along with the reinforcement before concreting, complete with 1.5 sqmm.FR PVC insulated multistrand copper conductor cable as earth continuity wire and piano type switch etc. complete in all respects. 45 Same as item above but for fan and light duty exhaust fan. 46 Same as item above but for 5 Amp plug point 47 S/F of hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16SWGM.S. sheet incorporating 10mm dia, M.S. round barduly bent for supporting fan hanger dully painted withred oxide and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting along with supply of all materials, labour T & P etc., for proper completion of work. 48 Supply fixing of electronic fan regulator 120-280 V. ISImarked, on the existing switch board including making connetion, required material, labour T/P etc for proper completion of work to the satisfaction of Engineer in charge of work. 49 S&F of LED Tube Light with batten complete including tube etc. on surface complete in all respect. 1x22 Watt 50 BORRING- 51 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge.(350mm dia) Upto 90 metre depth below ground level. 52 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge.(350mm dia) Beyond 90 metre & upto 150 metre depth below ground level. 53 Supplying, assembling, lowering and fixing in vertical position in bore well,unplasticized PVC medium well casing (CM) pipe of required dia,conforming to IS: 12818, including required hire and labour charges, fittings& accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia 54 Supplying, assembling, lowering and fixing in vertical position in bore wellunplasticized PVC medium well screen (RMS) pipes with ribs, conformingto IS: 12818, including hire & labour charges, fittings & accessories etc.all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia 55 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mmto 2 mm in recharge pit, in required thickness over gravel layer, for all leads& lifts, all complete as per direction of Engineer -in-charge. 56 Development of tube well in accordance with IS : 2800 (part I) and IS:11189, to establish maximum rate of usable water yield without sandcontent (beyond permissible limit), with required capacity air compressor,running the compressor for required time till well is fully developed,measuring yield of well by “V” notch method or any other approved method,measuring static level & draw down etc. by step draw down method,collecting water samples & getting tested in approved laboratory, i/cdisinfection of tubewell, all complete, including hire & labour charges ofair compressor, tools & accessories etc., all as per requirement anddirection of Engineer-in-charge. 57 Providing and fixing M.S. clamp of required dia to the top of casing/housingpipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 mm nominal size dia 58 Providing and fixing Bail plug /Bottam plug of required dia to the bottam of pipe assembly of tubewell as per IS:2800 (PART-1) 150 mm nominal size dia 59 Providing and fixing C.I. sluice valve 100 mm nominal bore. Class I 60 Providing and fixing G.I. pipes complete with G.I. fittings including trenchingand refilling etc.Submerssible to OHT 65 mm dia nominal bore 61 Providing and lowering G.I. pipes complete with G.I. fittings including trenching and refilling etc. 50 mm dia nominal bore 62 Supplyof tubewell motar pump 7.5 HP with control panel, support wire etc. complete one emergency pump . 63 Water supply tanker of 5000 litre capacity 64 Supply and fixing of nylon jali around the slotted pipescomplete as required. Up to 10 meter 65 Water testing report 66 FIRE ALARM, WET RISER / HYDRANT & SPRINKLER SYSTEM- 67 Providing, Laying, Testing & Commissioning of C- class heavy duty MS pipe on surface Confirming to IS 1239 (part-1) for pipes upto 150mm dia and IS: 3589-1991 for pipes above 150mm including cutting & welding with fitting like elbows , tees ,hanger ,flenges, taper , reducers, nuts, neoprene gasket & washer including cutting, welding etc. fixing the pipe on the Wall / Ceiling with suitable clamp and painted with red oxide and PO red enamel paint complete in all resspects. 68 200 mm Dia 69 150 mm Dia 70 100 mm Dia 71 80 mm Dia 72 50 mm Dia 73 32 mm Dia 74 25 mm Dia 75 Providing, Fixing,Testing & commissioning of 15 mm Dia quartzoid bulb type Sprinklers of rating 68 degree centigrade with required accessories. Pendant sprinkler / sprinkler 76 Supplying, fixing, testing & commission of butterfly valve ofPN-16 slim seal standerd lever operated type as per design standerd IS:1395 or BS:5155 with required flanges, nut bolts etc. complete in all respects. 77 200 mm dia 78 150 mm dia 79 100 mm dia 80 80 mm dia 81 Providing, installation, testing and commission of non-return valve offollowing sizes PN-10 as per design standerd IS: 5312 or BS:1868 with companion flanges, bolts, nuts, washers etc. complete in all respects. 82 150 mm dia 83 100 mm dia 84 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 30 mtr 85 SupplyingInstallationtesting& Commissioningof 25 mm Air Release valve gunmentalhavingrubberballandwith25 mm BSP threaded male inletincluding necessary accessories and connections complete in all respect. 86 SupplyingInstallationtesting& Commissioningof 25 mm Ball valve PN-1 gunmental as per IS:778 including necessary accessories and connections. 87 Providing & fixingofWeatherproofstandard fire hosecabinet boxmadeout of 18 gauge MSsheetincludingtwocoatsofpostoffice red paint over one coat of primer with 4 mm, thickglassdooronfrontpaintedFIREin red luminious paint, The size of thebox should be 750 mm X 600 mm X 250 mm size capable of accommodation a pair of hose with couplingand nozzel. The box should be floor mounted type with railway coach lock arrangementand leverfor openingthe door after breaking the glass complete. 88 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63mm dia male and female couplings duly bound with Gl wire, rivets etc. conforming to IS 636 (type-A) as required : Stainless Steel 89 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required: Stainless Steel (Grade 304) 90 Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump-450 Ipm at 35 m Head) 91 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required.. 92 Providing & fixing of pressure gauge in ranging from 0 to 14 kg per sqmm ISI marked from approved manufacturers complete in all respects. 93 Supplying fixing ofCast iron body 63 mm dia male instantaneousintelcouplingwith housing cabinet (500X400X400for 2 way and 600X400 for 4 way) cap and chain for fire brigadecorrection conformingto IS:904and makingconnectionwith fire fightingpipe or undergroundwater tank completing the work in all respect as per the directions of the Engineer-in-charge. Four Way connection 94 Providing/FixingofCubicaltypefloor mountedFire pump Controlpanel fabricated from16GM.S.sheetdulypowdercoated finish of aproved shade and comprising of: a) One 63 amp. TP+NL M.C.C.B. with rotary handle of beacking capacity 35 KA. b) One Volt meter (0-500V) with selector switch.c) One set including lamps 95 SupplyingLaying testing & Commissioningof 2 corex 1.5 sq.mmsingle standard copper conductor, PVCinsulatedarmored cable. 96 Supply and laying of alluminium conductor PVC insulated armoured served sheathed cables 1100 volts grade at a depth of 750 mm below ground level over a cushion of 75mm thick sand all around and protected with burnt bricks on side and on top on surface the cable run shall be fied on M.S. clamps etc. of suitable size or as directed by the Engineer-in-charge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 97 150 sqmm 3-1/2 core 98 50 sqmm 3-1/2 core 99 3.5 Corex35 Sqmm AL Cable 100 16 sq. mm 4 core 101 10 sqmm 4 core 102 Supply, Installation, Testing & commissioning of Single/Double sided Signage with 20 mtr. viewing distance with built in LED, High efficiency L80 LED with 50,000 hour life, Usage: Exit Signage cum Emergency light with Function Use either as an emergency luminaire or exit sign, with standalone Testing system, Housing of Polycarbonate, Glow wire test : 850°C, RAL9003, Type of mounting: Wall or ceiling, Operation Mode Non -Maintained or Maintained mode selectable, Connection voltage 230V +/- 5% [220V-240V], compliant with EN standards, with IEC CB test certificate LED, Built in Battery: Ni-Cd, Duration 3 hours, Viewing distance 2+A300m, Dimensions in mm: 270 x 119 x 49. 103 P&F of Fire man axe made of carbon steel handle insulated with rubber tested to 20,000 Volts. Manufactured as per Indian standard IS:926. 104 Providing and fixing pressure switch in M.S. pipe line including connection as required 105 Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fitting and base support for tank.[Sintex, Electroplast, Star, Lotus or equivalent having valid ISI license]. 106 Supply and fixing of Single way landing / Hydrant / Yard Hydrant valve 63 mm dia. Gun metal instantanous with female coupling with chain etc. complete: Single Headed Gunmetal. 107 Surfacedressingofroadwithpainting betweenusing 2.25 kg. of bitumenper sq.mt with 1.65 cum of stone chipping ,13.2 mm nominal size/100 sq.mt of road surface including corolidation. 108 Supply, Installation, Testing & Commissioning of Electric Driven Main Fire Pump Suitable for auto operation & consisting of following: complete in all respect as required. Horizontal split Casing type, centrifugal, multistage, pump of cast iron body & bronze impeller with stainless steel shaft Mechanical seal at specified flow of 1620 lpm at 70 Meter head confirming to IS 1520. Suitable HP squirrel cage induction motor,TEFC synchronous speed 1500 RPM 60 HP (with permissible slip) suitable for operation on 415 volts, 3 phase 50Hz.AC with IP 55 protectiion for enclosure, horizontal foot mounted type with class- F insulation, conferming to IS-325 Common base frame fabricated out of M.S channel of suitable size flexible coupling, coupling guard, foundation bolt & pressure gauge with valve etc. Suitable cement concrete foundation duly plastered, with anti vibration pads etc. complete as per detailed specifications. 109 Supply, Installation, Testing & Commissioning of Diesel Engine Driven main fire pump suitable for auto operation & consisting of following: complete in all respect as required. Horizontal split Casing type,centrifugal, multistage, pump of cast iron body & bronze impeller with stainless steel shaft, Mechanical seal at specified flow of 1620 lpm at 70 meter head confirming to IS 1520. Suitable HP 1500 RPM, 4 stroke, cold starting type Diesel Engine with Heat Exchanger confirming to relevant BIS & IS Standards, complete with all required accessories/system, fuel oil filter ,lubricant oil pump with filter, 1 set Starting batteries of 180AH capicity each with suitable angle iron stand,engine starting panel havng all the controls meters, gauges, techo meter,hour meter, starting switch with keys for manual starting, auto starting mechanism, 12/24 volt electric starting equipment, Deisel tank for 8 hrs continuous running for Diesel Engine having minimum capicity of 200 Ltrs. (Tank made out of 3mm thick M.S.Sheet with filling cap, drain cock, diesel indicator duly mounted on M.S.angle) exhaust pipe of minimum 10 mtr. length, duly insulated with 50 mm thick glass wool with 1.0 mm.thick alluminium sheet cladding, exuast reidential silencer,stop solenold for auto stop in the event of fault with audio indications, painting etc. as required. M.S fabricated Common base frame,flexible coupling, coupling guard, foundation bolt & pressure gauge with valve etc. Suitable cement concrete foundation duly plastered, with anti vibration pads etc. complete as per detailed specifications. 110 Supplying, fixing, testing & commission of Electric Driven Pressurisation Pump (Jockey Pump) suitable for auto operation consisting of following complete in all respect as required. Horizontal type, centrifugal & suction type, pump of cast iron body & bronze impeller with stainless steel shaft Mechanical seal, gland packing & flow of 180 lpm at 70 Mtr. Head confirming to IS:-1520. Common base frame fabricated out of M.S channel of suitable able size flexible coupling, coupling guard, foundation bolt & pressure gauge with valve etc. Suitable cement concrete foundation duly plastered, with anti vibration pads etc. complete as per detailed specifications. 111 Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter-connection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection classIP 42 as required : INCOMING 630A, 50kA 4 Pole MCCB, Ics=100% lcu rating Digital Voltmeter 0-500V with selector switch Ammeter (0-630 A) with selector swtich & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 800Amps OUTGOING ( Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps) MAIN FIRE PUMP250 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 100 hp pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.JOCKEY PUMP 125 A, 50kA TPN MCCB, Ics=100% lcu, with Suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.DIESEL ENGINE CONTROL Control for diesel engine comprising - Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0-20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine. SYSTEM CONTROLLERDesigning, Supply, Installation,esting and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification 112 SITC Automatic priming arrangement for all fire pumps including necessary pipe, fitting, water level controller, 1 HP pump, auto starter gate valve NRVs etc complete. 113 FIRE ALARM SYSTEM- 114 Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 + 5 % V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. Two Loop Panel 115 Supplying, installation, testing & commissioning of intelligent analog addressable photothermal (smoke cum heat) detector complete with mounting base complete as required. 116 Supplying, installation, testing & commissioning of intelligent addressable thermal (heat) detector with rate of rise cum fixed tempreature thermistor complete with base as required. 117 Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. 118 SupplyingInstallationtesting& Commissioningof Intelligent Addressable Manual Call points- double action Break Glass cum pull station suitable for wall/column mounting. 119 SupplyingInstallationtesting& Commissioningof Intelligent Addressable Hooter cum multi carriar strobe.Unit as per specificationsand customizationof intensity selectionas15,30 , 75 or110cdof strobe unit is possibleby panel.Soundersum strobe willbedrivenbysupervised24 V DCinput and will give 80 db output at 3 m strobe unite willbesynchronized1Hzstrobeflashrate for better evacuation in complete facility. 120 SupplyingInstallationtesting& CommissioningIntelligent Addressablesingle AddressableControl Relay Module-Form C contacttype. 121 Supply & fixing of CO2 type fire extinguisher,4.5 kg. capacity (ISI Marked IS:2878 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 122 Supply & fixing of fire extinguisher, ABC Type 4.00 kg. capacity (ISI Marked IS:15683 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 123 REPAIRING WORK- 124 Making Holes with core cutting as per specified dia & depth including stacking of dismantled materials as directed by Engineer-in-charge with in a distance of 60 meters. 125 25 mm dia (9) 126 32 mm dia (9) 127 50 mm dia (9) 128 80 mm dia (9) 129 100 mm dia (9) 130 150 mm dia (9) 131 Grounting of holes with plaster & painting with matching color as per specified dia & depth including cost of materials complete in all respects as directed by Engineer-in-charge. 132 25 mm dia 133 32 mm dia 134 50 mm dia 135 80 mm dia 136 100 mm dia 137 150 mm dia 138 Drilling & Grounting of holes with DE-Walt Pure 150- Pro Chemical as per specified dia & depth including cost of materials complete in all respects as directed by Engineer-in-charge. 16 mm dia (9) 139 SIGN BOARD- 140 Providing & erecting direction & place identification& other fire related informations for emergency retro- reflectorised sign as per IRC-67 made of high intensity grade sheeting. The retro reflective sheeting type-IV shall be tested for 3 year outdoor weathering test in Indian conditions as per IRC 67:2012 & proof of the same in form of government report shall be uploaded while quoting tender vide clause 801.3 fixed over aluminium sheeting, 2mm thick with area exceeding 0.9 sqm. Supproted on a mild steel single angle iron post 75x75x6 mm, 2 nos firmly fixed to the ground by means of property designed foundation with M-15 grade cement concrete 45x45x60 cm below ground level as per approved drawing complete. 141 TRAINING- 142 RESOURCES TRAINING FOR STAFF & TRAINING MODULES FOR RESCUE OPERATION. 143 GST Extra as per applicable
Contract Date : Ref. Documents   |   Contract Value : Ref. Documents
BRR : 10427022 Construction Of Sump Well Pump Room And Sitc Of Rotary Lobe Pump Sets Along With Related Eandm Equipments At Rahim Khan Road Nizamuddin East New Delhi Under Ser-1 Civil And Electrical Work-SH-I Pump Set WorkSupplying, installation, testing and commissioning of Positive displacement Rotary Lobe Pump for draining/dewatering of storm water/sewer water compatiblefor VFD (variable frequency drive) having minimum discharge 500 m3 /hr at 68Hz and 170 m3/hr at 25 Hz for 10 mtr. head and 5 mtr. suction Lift capacity complete withGeared Motorwith minimum power 45 kW/60 HP, 4 Pole suitable for operation on 415 Volt 50 Hzas per additional specification etc. as required. 2 Supplying, fabrication & installation of45KW VFD AUTO CONTROL PANEL made out of CRCA sheet steel of thickness 2mm for load bearing members, 1.6mm for non load bearing section with necessary stiffeners as required. 3 Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required: 4 250 m.m dia 5 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, Gl bolts, nuts, washers etc.as required: 6 250 m.m dia 7 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required: 8 40 mm dia 9 80 mm dia 10 250 mm dia (wall thickness 6.3 mm) 11 450 mm dia (wall thickness 7.0 mm) 12 Fabrication, Supplying, Installation Testing & commissioning of automatic motorised Mechanical Coarse Bar Screen Suitable for channel dimension:i) Channel width: 1000mmii) Channel Depth: 3500 mmiii) Water Depth: 1500 mmiv) Bar Spacing: 20 mmv) Bar size : 12X6X50 mm vi) Angle: 75 Degreevii) MOC: SS304 Peak Flow/ Screen: 27MLDi/c Supplying, Installation, Testing & commissioning of 1No relay based control panel made out of 2mm thick CRCA sheet for 2Nos. Mechanical Coarse Bar Screen & 1No.Belt Conveyor etc. complete as required. - 13 Supplying, Installation, Testing & commissioning of Differential Level Sensorcomprises of Two Ultrasonic Level Sensors and One Differential Transmitter for Mechanical coarse bar screenetc. complete as required. 14 Supplying, Installation Testing & commissioning ofBelt Conveyor of size 600 mm width and2000mm Length i/c accessories for screen etc. complete as required. 15 Supplying, Installation Testing & commissioning of Gate Assy FG A101 Cast Iron Side Wall Embedded Oen Channel Gate (101) Size: 1000(W) X 1000 (H) mm Suitable for 1.75 m Seating water head (From invert Level) , Flush Bottom Closure Arrangement , Manually operated, Close Top Frame Gate etc. complete as required. 16 Supplying, Installation Testing & commissioning of Ultrasonic Level Transmitter with 4 ANSI PP Flange etc. complete as required. 17 Supplying, Installation Testing & commissioning of Local Control Stations for Pump Motors having following accessories i/c making connections etc. complete as required:a)DP MCB, 10kA, C-Curve for Control, 6A;: 1 No.b)Ampere meter, SIF-96, CI-1, Aux Supply 230V AC; 4-20mA I/P;1 No.c)Indicating Light-RED for ON;1 No.d)Indicating Light-AMBER for TRIP;1 No.e)Push Button with 1 NO contact - GREEN for VFD START;1 No.f)Push Button with 1 NC contact - RED for VFD STOP;1 No.g)Push Button with 1 NC contact - Mushroom head RED;1 No.h)Thermistor Relay 252 PMTG;1 No.i)Control Terminals, 2.5 sqmm; 6A;22 Nos. 18 SH-II Diesel Generator SetSupply, installation, testing and commissioning of Silent Type, CPCB IV + emission compliants Diesel Generating set having Prime Power Rating of 200 KVA, at 1500 RPM, 0.8 lagging power factor at 415V suitable for 50 Hz, 3 Phase system & for 0.85 Load Factor with all necessary equipments and accessories and consisting of followings :(a)Diesel EngineDiesel engine 4 stroke water cooled, electric start, of suitable BHP at 1500 RPM suitable for above output of alternator at 40 degree C, 50 % RH & at 1000 meterMSL and conforming to BS 5514, BS 649, IS 10000(amended upto date), capable of taking 10 % overloading for 1 hourafter12hourofcontinuousoperation.Theenginewillbefittedcompletewithall accessories as per specifications .(b)Enginemountedinstrumentpanelfittedwithandhavingdigitaldisplayforthe following :-(i) Start stop switch with Key (ii) Water temperature indication (iii) lubrication oiltemperatureindication(iv)lubricationoilpressureindication(v) Batterycharging indication (vi) RPM indication (vii) Over speed indication (viii)Low lube oil trip indication(ix) Engine hour indication. 19 (c)AlternatorSynchronous alternator rated at 200 KVA, 415V, at 1500 RPM, 3 Phase, 50Hz, AC Supply with 0.8 lagging power factor at 40 Degree C, 50% Relative Humidity & at 1000m above MSL. The alternator shallbehavingSPDPenclosure,brushless,continuousduty,self-excitedandself-regulatedthrough AVR, confirming to IS: 4722 /BS : 2613suitable for tropical conditions and withF/H insulation.(d) Base Frame &foundation: Both the Engine & alternator shall be mounted on suitable baseframemadeofMSchannelwithnecessaryreinforcementwhichshallbeinstalledon suitablecementconcretefoundationandvibrationisolationarrangementasper recommendations of manufacturer.(e) Fuel Tank : Daily service fuel tank ofminimum 385 Ltr capacity fabricated out of 3mm thick MS sheet complete with all standard accessories and fuel piping between fuel tank & diesel engine with MS class C Pipe of suitable dia complete with valves, level indicators, and accessories as required as per specification.(f) Exhaust System : Dry exhaust manifold withsuitable exhaust residential gradesilencer . 20 (g) Starting system : 24V DC starting system comprising of starter motors, voltage regulator and arrangementforinitialexcitation,completewith suitableno. of batteries(25Plates,180 AmpsHour Capacitylead acid type) as required as per specification.(h) Acoustic Enclosure : Acoustic and weather proof enclosure with arrangement for fresh airintakeforcoolingoftheengineandalternator,extractiondischargeofhotairinto atmosphere as per specifications. 21 AMF Panel(i) Fabricating,Installation, Testing & Commissioningofautomaticmainsfailurecontrolincludingautobypasspanel,suitable for 200 KVAsilenttypeDGsetcompletewithrelays,timers,setofCTs,formeteringand protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, KVARH& Provision for overload, short circuit, restricted earth fault, under frequency, control cabling from AMF panel to Diesel Engine and elsewhere, if required, all complete and interlocking including the following :-(a) 3 nos. 400 A 36KA, 4 Pole with thermo-magnetic release double break MCCBwith O/L,S/C & E/Fprotection with Aux . And trip contact and shunt release.(b)Auto / manual /test/off selector switch.(c) 2 nos. over voltage relay, 2 nos. reverse power relay and 2 nos. under voltage relay.(d)1 no. Auto mains failure relay(e) 3 sets of current transformer15P 10 accuracy for protection andclass 1, 15VA class-Ifor metering and. AMF Relay.(f) Energy analyzer unit to indicate current, voltage, frequency power factor and KWH.(g) Indicating lamps for load on mains and load on set.(h) Fuse for instruments.(i) Battery charger, complete with all accessoriesand Ammeter,voltmeter etc. 22 (j) Supply failure& restoration timer(k) Main supply failure monitor(l) Control unit with three impulse automatic engine start/stop and failure to start lock out.(m) Impulse counter with locking and reset facility.(n) ON/OFF/Control circuit switch with indicator.(o)Aux. contactor 2NO+2NC(p) Audio/Video annunciation for :(i) High water temperature.(ii) Low lubricating oil pressure.(iii) Engine over speed(iv) Engine fails to start.(v) Full load/ Maximum load warning. 23 Main LT PanelSupplying, installation, testing & commissioning of LT panel of minimum front area 3.15 sq. mtr. and depth not less than 45 cm, made out ofCRCA Sheet Steel 2mm for section with necessary stiffeners as required. Free standing, self supported, floor mounting, single front, indoorinstallation, non draw out and compartmented. ISMC-100 fabricated channel frame with undrilled holes.Bottom with undrilled detachable 3mm gland plate as per order .Welding will be carried out with no external deposition of welded material in particular places and there will not be any gap between the welded materials.Siemens Grey RAL 7032CRCA Structures shall be pre-treated in seven tank chemical process, heated in baking oven.Minimum 60 micron of approved shade (RAL-7032).230V AC for Main LT Panel and Other Panels415+/- 5% , 50Hz+/-5%, 3 Phase 4 Wire 50KA – 1 Sec TPN Aluminum Electrolytic Grade ( E-91E) busbar shall be provided as per suitable sze, duly supported on SMC/DMC, busbar supports & insulated with color coded heat shrinkable sleeve. Power wiring will be through Vertical Bus -Bar and 1.1 KV grade PVC multistrand copper flexible cable . All control wiring will be done by 1.5 sq mm copper flexible PVC multi strand wire. CT wiring shall be carried out with 2.5 sq mm copper flexible PVC multistrand wire.1. All R,Y,B,N phases will be Red, Yellow , Blue & Black 2.All control wiring will be Grey colour. Earthing shall 24 be be with Green color wire.3.C.T. - Wiring through Red, Yellow, Blue, Black coloured wiring with shorting link type terminals.EPDM gasket provided at all joints, doors & covers to make panels dust & vermin proof (IP-52)Section-I(a) INCOMER :-1No. 4nos. 400 A 36KA, 4 Pole with thermo-magnetic release double break MCCBwith O/L,S/C & E/Fprotection with Aux . And trip contact and shunt release. Ics=100%Icu i/c extended rotary handle and spreaders and all required accessaries Digital 96 mm square flush pattern type Voltmeter (0-500 V) with selector switch & back up HRC fuses/MCBs … complete 1 set.Digital 96 mm square flush pattern type Ammeter (0-400 Amp)with selector switch and one set of 3 Nos. CTs of ratio 400/5A class 1 accuracy and 10 VA burden - 1 set.Indicating lamp On, OFF, TRIP /R/Y/B/Ready to close…complete 1set(b) 400 AOnload Change over SwitchIcs=100%Icu i/c extended rotary handle and spreaders and all required accessories- 1setIndicating lamp On, OFF, TRIP /R/Y/B/Ready to close complete 1set(c) OUT GOINGS:- 4Nos. 100A FP MCCB ( 25kA) with thermo-magnetic release i/cextended rotary handle & spreaders. Ics=100%Icu etc complete as reqd. 25 Digital 96 mm square flush pattern type Voltmeter (0-500 V) with selector switch etc complete 1 set.Digital 96 mm square flush pattern type Ammeter (0-400 Amp)with selector switch and one set of 3 Nos. CTs of ratio 400/5A class 1 accuracy and 10 VA burden - 1 set.Indicating lamp On, OFF, TRIP /R/Y/B/Ready to close…complete 1set3 Nos. 63A FP MCCB ( 25kA) with thermo-magnetic release i/cextended rotary handle & spreaders. Ics=100%Icu etcwith indicating Lamps complete as reqd. 26 SH-III EI Work Supplying & Laying of one number PVC sheathed XLPE insulated power cable of 1.1 KV grade of following size on cable tray as required. 27 3.5 x 240 Sq.mm XLPE Al Conductor Armoured Cable (clamped with 40x3mm MS flat clamp) 28 3 X 50 sq mm (clamped with 25x3mm MS flat clamp) 29 Supplying, Laying and fixing of XLPE insulated and PVC sheathed aluminium conductor armoured Power Cableof 1.1 KV grade of following sizes on wall surface etc. as required. 30 4X25 Sq. mm. (clamped with 1mm thick saddle) 31 Supplying & Laying and fixing of one number PVC sheathed XLPE insulated power cable of 1.1 KV grade of following sizedirect in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 32 3.5 x 240 Sq.mm XLPE Al Conductor Armoured Cable 33 Supplying and Laying of XLPE insulated and PVC sheathed Copper conductor armoured Power Cable of 1.1 KV grade of following size on cable tray as required. 34 4x4 Sq.mm. 35 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 36 3½ X 240 sq. mm (62mm) 37 3 X 50 sq. mm (32mm) 38 4 X 25 sq. mm (28mm) 39 Supplying and drawing following size of PVC insulated copper conductor multicore cable of following size on cable tray as required. 40 10 core 1.5 sq.mm 41 24 core 0.5 sq.mm 42 4 core 0.5 sq.mm 43 2 core 1.5 sq.mm 44 6 core 0.5 sq.mm 45 3 core 0.75 sq.mm 46 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 47 100 mm width X 50 mm depth X 1.6 mm thickness 48 450 mm width X 50 mm depth X 2.0 mm thickness 49 EarthingEarthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 50 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 51 Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode includingconnectionwithbrassnut,bolt,spring,washerexcavationandre-fillingetc.as required. 52 Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. 53 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode includingconnectionwithG.I.nut,bolt,spring,washerexcavationandre-fillingetc.as required. 54 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. asrequired. 55 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. 56 Group C 57 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 58 3 x 4 sq. mm 59 Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 60 25 mm 61 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. 62 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 63 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 64 4 way (4 + 12), Double door 65 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 66 Single pole 67 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 68 63 amps 69 Supplying, Installation, testing & commissioning of weather proof LED Corrosion resistant battentype LED fitting of following wattagewith IP65 body made out of polycarbonate housing & opal diffuser with better thermal managementCCT-5700°KLumen Efficacy ≥110 Lm/W Power Factor≥ 0.95, CRI≥70, with constant current driver etc. complete as reqd. 70 36 Watt (4 feet ) 71 SITC of 450 mm heavy duty Exhaust Fan 1400 RPMsingle phase 240 Volt 50 Hz in the existing opening, complete with heavy duty louver/ shutter i/c making the hole to suit the size of the above fan, making good the damages, connection, testing, commissioning & earthing etc. as required 72 SITC of 600mmwall mounted fan having 3 nos. of blades, 1440RPM etc complete as reqd. 73 SH-IV AMCAMC for pump sets, Motor control panel and other accessories starting after satisfactory completion defect liability period from date of completion and commissioning of the pumping system.Annual Comprehensive maintenance for all 3 Nos. Pump sets, Motor, VFD Auto control panel, Mechanical Course Bar Screen, Differential Level sensor, Ultra Sonic Level Transmeter, Belt conveyor, Gate assembly including all accessories and consumables etc. all complete and as per site requirement as per Engineer-in-charge. 74 For 1st Year (Free Maintenance period) 75 For 2nd Year 76 For 3rd Year 77 Comprehensive maintenance of 200 KVA Silent type DG Set with AMF Panel. Annual Comprehensive maintenance of 200 KVA DG set and its accessories with AMF Panel i/c repairing, servicing, cleaning, checking and Descaling with replacment of following consumable parts i.e oil filter, fuel filter, air filters, coolant, lube oil, coolant filter, battery water, V Belts and batteries etc. complete and as per site requirement as per Engineer-in-charge. 78 For 1st Year (Free Maintenance period) 79 For 2nd Year 80 For 3rd Year 81 Civil WorkDemolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 82 Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) 83 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. 84 All kind of soil. 85 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. 86 Providing and laying in position ready mixed or site batched design mix cement concrete for plai plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/ Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads: but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 87 Concrete of M10 grade with minimum cement content of 220 kg /cum 88 Centering and shuttering including strutting, propping etc. and removal of form for all heights : 89 Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. 90 Suspended floors, roofs, landings, balconies and access platform 91 Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick 92 Edges of slabs and breaks in floors and wallsAbove 20 cm wide 93 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work;usingcoarse aggregate and fine aggregate derived from natural sources,Portland Pozzolana / Ordinary Portland /Portland Slagcement,admixtures in recommended proportions as per IS: 9103 to accelerate /retard setting of concrete, to improve durability andworkabilitywithout impairing strength; including pumping of concrete to site of laying, curing,carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge;for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately.In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works upto plinth level Concrete of M25 grade withminimum cement content of 330 kg /cum 94 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 95 Thermo-Mechanically Treated bars of grade Fe-500D or more. 96 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : 97 Cement mortar 1:4 (1 cement : 4 coarse sand) 98 12mm cement plaster of mix 1:4 (1cement:4 fine sand). 99 15 mm cement plaster on rough side of single or half brick wall of mix: 1:4 (1 cement: 4 coarse sand) 100 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 101 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : 102 New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than50 gram/litre 103 Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m :Ordinary roack 104 Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm 105 Providing and fixing soil, waste and vent pipes : 100 mm dia. : 106 Sand cast iron S&S pipe as per IS: 1729. 107 Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : 108 Circular shape 450 mm dia 109 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 110 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 111 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 112 White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps 113 Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.100 mm : 114 Sand cast iron S&S as per IS - 1729 115 Providing and fixing plain bend of required degree : 100 mm 116 Sand cast iron S&S as per IS - 1729 117 Providing and fixing single equal plain junction of required degree: 100x100x100mm, 118 Sand cast iron S&S as per IS-1729. 119 Providing and fixing terminal guard: 100mm : 120 Sand cast iron S&S as per IS:1729. 121 Providing and fixing collar:100mm : 122 Sand cast iron S&S as per IS:1729. 123 Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter : 124 100mm : 125 Providing and fixing trap of self cleanising design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 100mm inlet and 100mm outlet : 126 Sand cast iron S&S as per IS:3989. 127 Providing and fixing PTMT 15 mm Urinal spreader size 95x69x100 mm with 1/2 BSP thread and shapes. Weighing not less than 60 gms. 128 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc : Externalwork : 129 25mm dia nominal bore. 130 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing Tees including cutting andthreading the pipe etc. complete : 131 25 to 40mm nominal bore. 132 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc : Externalwork : 133 32mm dia nominal bore. 134 Providing and fixing C.P. brass bib cock of approved quality confirming to IS :8931 : 135 15mm nominal bore. 136 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make confirming to IS:8931 : 137 15mm nominal bore. 138 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 139 25mm nominal bore. 140 Providing and fixing ball valve (brass) of approved quality, High or low pressure with plastic floats : 141 25mm nominal bore. 142 Providing and fixing brass ferrule C.I. mouth cover including boring and taping the main : 143 25mm nominal bore. 144 Providing and fixing unplasticised PVC connection pipe with brass unions : 45cm length : 145 15mm nominal bore. 146 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 147 Providing and fixing PTMT grating of approved quality and colour : Circular type : 148 100mm nominal dia. 149 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying a priming coat of approved steel primer : E.R.W. tubes. 150 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer)with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand)jointing with grey cement slurry @3.3 kg/sqm including grouting thejoints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only .Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. 151 Size of tile600x600mm. 152 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.(i) Single socketed pipes.Single socketed pipes : 153 110mm diameter. 154 Providing and fixing on wall face unplasticised –PVC moulded fittings / accessories for unplsticised rigid PVC rain water pipes confirming to IS:13592 Type A including jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expansion : Bend 87. 5° : 155 110mm bend. 156 Providing and fixing on wall face unplasticised –PVC moulded fittings / accessories for unplsticised rigid PVC rain water pipes confirming to IS:13592 Type A including jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expansion : Shoe (Plain) : 157 110mm Shoe. 158 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : 159 Two or more coats on new work. 160 Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required : 161 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. 162 Providing and laying in position ready mixedor site batched design mix cement concrete for plain cement concrete work;usingcoarse aggregateandfine aggregate derived from natural sources and usingrecycled concrete aggregate (RCA)as coarse aggregate and fine aggregate within thepermissible utilization,PortlandPozzolana / Ordinary Portland/Portland Slag cement,admixtures in recommended proportions as per IS: 9103 to accelerate /retard setting of concreteto improvedurability andworkabilitywithout impairing strength;including pumping of concrete to site of laying, curing,carriage for all leads; but excluding the cost of centering, shuttering and finishingas per direction of the engineer-in-charge; for thefollowing grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works upto plinth level 163 Concrete of M25 grade with minimum cement content of 300 kg /cum.(Note: The permissible utilization of Recycled Concrete Aggregate (RCA) as coarse aggregate and fine aggregate is 25% each). 164 Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design: 165 With 20x20 mm square bar 166 Providing and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS : 8329 : 167 450 mm dia Ductile Iron Class K-9 pipes. *For use of bigger dia. pipes other than 450mm, net difference in basic rate as per applicable DSR shall be reimbursed to the contractor. 168 Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by Engineer-in-Charge and consisting of :(i) Ist layer of 22 mm to 25 mm thick approved and specified rough stone slab over a 25 mm thick base of cement mortar 1:3 (1 cement : 3 coarse sand) including applying of twice ( at base and top of mortar ) cement slurry @ 2.2kg/m2 (each time) mixed with water proofing compound conforming to IS:2645 in the recommended proportion over the leveling course (leveling course to be paid separately). Joints sealed and grouted with cement slurry mixed with water proofing compound. 169 (ii) 2nd layer of 25 mm thick cement mortar 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportions.(iii) Finishing top with stone aggregate of 10 mm to 12 mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer.Using rough kota stone. 170 Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22 mm to 25 mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20 mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement : 3 coarse sand) 20 mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by Engineer-in-charge : 171 Using rough Kota stone 172 Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 173 Providing sand stone slab for roofing and laying them in cement mortar 1 : 4 (1 cement : 4 coarse sand) over wooden karries or R.C.C. battens or structural steel sections (Karries or battens or structural steel sections to be paid separately), including pointing the ceiling joints with cement mortar 1:3 (1 cement : 3 fine sand ) complete : 174 Red sand stone slab40 to 50 mm thick 175 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces 176 40 to 50 mm thick 177 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, priming coat of approved steel primer, but excluding the cost of other fittings, glass panes complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 178 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) 179 Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. 180 Made of G.I. wire of dia 4 mm 181 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 182 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 40 mm nominal size derived from natural sources) 183 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 184 Modified estimated cost after using correction factor on DSR-2023 on account of GST @0.973 vide O.M. dated 08.08.2024.(i.e. 9720555 *0.973 = 9458100 185 Carrying out structural analysis and design of all civil work, Design of all E&M works, foundation and superstructure of work such as pump-room, UGT and Delivery line upto Barapullah Drainage etc. all complete and submission of input data, check print structural drawing, 6 Nos. prints with soft copy of analysis and drawings as per direction of Engineer-in-Charge by approved structural consultant agency. The profile of structural consultant shall be got approved from NIT approving authority. The structural design shall be comprehensive to enable easy servicing of pumps and other heavy equipment’s etc. possible. The Hydrological data shall be provided to the consultant for drainage design.
Contract Date : Ref. Documents   |   Contract Value : Ref. Documents
BRR : 9460897 Tender for construction work of Kalyan Mundap at Khasra No. 55, Daud Nagar, Faizullaganj, Lucknow., 1 Shelter House (Part - A) 2 Earth work in excavation by mechanical means (Hydraulic excavator) I manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 3 Constuction of subgrade with material obtained from avaliable land (for local earth work) Construction of embankment with approved material obtained from avaliable land as pormited and approved by engineer-in-chage and as per technical specification clause 301.3.4.1 with all lifts and leads, spreading grading to required slope and compacting to meet requiredment of table 300.0 and 300.2 as per technical specification clause 301.5 with centre up to 15 km.(by Analysis) 4 Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 em deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. 5 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 6 Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20% 7 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Along external wall where the apron is not provided using chemical emulsion@ 7.51itres I sqm ofthe vertical surface of the substructure to a depth of 300 mm including excavation channel along the wall & rodding etc. complete: With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration 8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level. 1:4:8 (1 Cement : 4 coarse sand (zone-Ill) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 9 Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-Ill) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 10 Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete 11 Centering and shuttering including strutting, propping etc. and removal of form for Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. 12 Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform. 13 Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers 14 Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts 15 Centering and shuttering including strutting, propping etc. and removal of form for staircases (including landing) 16 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-5000 or more. 17 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana I Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate I retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.:N Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% ofthe specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum (M-25 up to plinth level) 18 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana I Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate I retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.:N Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% ofthe specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works above plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg /cum(M-25 above plinth level) 19 Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. 20 Brick work with common burnt clay (non modular) bricks of class -150in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) 21 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. 22 Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately) 23 Providing and laying autoclaved aerated cement blocks masonry with 100 mm thick AAC blocks in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work. 24 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 sqm 25 Providing and Fixing Ist quality ceramic glazed wall tiles conforming to IS :15622 (thickness to be specified by the manufacturer), of approved make in all colours, shades except burgundy, bottle green,black of any size as approved by Engineer-in-charge, in skirting, risers of steps and dados, over 12mm thick bed of cement mortar 1:3 (1 cement :3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm , including pointing in white cement mixed with pigments of matching shade complete. 26 Providing and fixing frame work for partitions/ wall lining etc. made of 50x50x1.6 mm hollow MS tube, placed along the walls, ceiling and floor in a grid pattern with spacing @ 60 cm centre to centre both ways (vertically & horizontally) or at required spacing near opening, with necessary welding at junctions and fixing the frame to wall/ ceiling/ floors with steel dash fasteners of 8 mm dia, 75 mm long bolt, including making provision for opening for doors, windows, electrical conduits, switch boards etc., including providing with two coats of approved steel primer etc. complete, all as per direction of Engineer-in-charge. 27 Providing and fixing factory made 18 mm thick single extruded WPC (Wood Polymer Composite) solid plain white colour board Jali, CNC (Computer numeric control) routed of approved design by Engineer in -charge which are machine cut for duct/shaft covering, partitions and facades comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium corbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives(maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/ cum and screw withdrawal strength of 1800 N (Face) minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with properties of being termite/borer proof, water/moisture proof and fire retardant and fixing on M.S (mild steel) frame made of 25 x 25 x 1.5 mm square hollow box section including applying a priming coat of approved steel primer, placed at grid made at 1.0 x 1.0 m or as per requirement at site with necessary stainless steel fasteners and SS screws etc., all complete as per direction of Engineer-In- Charge. (Note: M.S (mild steel) framework with priming coat and necessary SS fasteners and SS screws shall be paid separately. 28 Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile B Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) 29 Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile E Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) 30 Casement door double panel with French (False) Mullion with zinc alloy (zamak) 3D hinges, multi-point locking system with cylinder, zinc alloy (zamak) powder coated handles on both sides.Using R4 series with frame (64 mm & above) x (55 mm & above) & sash (64 mm & above) x (100 mm & above) & French (False) mullion (64 mm & above) x (60 mm & above). (Height above 2.5 metre). 31 Fixed window I ventilator without mullion I transom. Using R 1 series with frame (33 mm & above) x (35 mm & above). (Height upto 0.90 metre) (UPVC Window) 32 Casement window double panels with fixed mullion with S.S. 304 friction hinges as per size and weight of sash, multi-point locking system, zinc alloy (zamak) powder coated handles. Using R2 series with frame (39 mm & above) x (39 mm & above) & sash (39 mm & above) x (60 mm & above) & mullion (39 mm & above) x (60 mm & above). (Height upto 1.2 metre). (UPVC Window) 33 Casement window single panel with S.S. 304 friction hinges as per size and weight of sash, multi-point locking system, zinc alloy (zamak) powder coated handles. Using R4 series with frame (64 mm & above) x (50 mm & above) & sash (64 mm & above) x (70 mm & above). (Height above 1.8 metre) (UPVC Window) 34 Providing and fixing lSI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including lSI marked Stainless Steel butt hinges with necessary screws 35 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.0 mm thick 36 Providing and fixing ISI marked Stainless Steel sliding door bolts with nuts and screws etc. complete. 250x16mm 37 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 200x10mm 38 Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : 100mm 39 Providing and fixing aluminium hanging floor door stopper, lSI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Single rubber stopper 40 Float glass panes 5.0 mm thick glass panes (weight not less than 12.50 kg/sqm). 41 Fly proof stainless steel grade 304 wire gauge with 0.5 mm dia. wire and 1 .4 mm wide aperture with matching wood beading 42 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces 43 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). 44 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 45 Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 m dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge. 10x 160 mm 46 Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). 47 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in allcolours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. Thetiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Double charge vitrified tile polished finish of size Size of Tile 600 x 600 mm 48 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm 49 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent 50 Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : 51 Chequered terrazo tiles 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) : 52 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) 53 6 mm cement plaster to ceiling of mix : 1:3 (1 Cement : 3 fine sand) 54 15 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement: 6 coarse sand) 55 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 56 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 57 Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats 58 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work 59 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills,diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :12.5 mm thick tapered edge gypsum moisture resistant board. 60 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.(c) The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixedslurry. 61 Supplying and Stacking Filling sunken floor with over burntjhama brick aggregate 120mm to 40mmincluding compacting of materials complete as specified and directed for all levels. 62 Providing and applying integral crystalline slurry of hydrophilic innature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. For vertical surface two coats @ 0.70 kg per sqm 63 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm 64 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS 2845 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement: 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement 5 coarse sand) admixed with water proofing compound conforming to IS: 2845 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs (c) After two days of proper curing applying a second coat of cernent slurry using 2.75 kg/ sam of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1) cement 4 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge including laying glass fibre cloth With average thickness of 120 mm and minimum thickness at khurra as 65 mm 65 FIRE FIGHTING (PART - B) 66 Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) 67 (a)Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 68 b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-F insulation, conforming to IS-325. 69 (c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. 70 (d) Suitable cement concrete foundation duly plastered and with anti vibration pads. 71 450 lpm at 35 m Head 72 Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required 73 Air Release Valve, Gunmetal, having rubber ball with 1” (25mm) BSP Male threaded inlet 74 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. 75 Providing, laying,of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 100 mm dia 76 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :100 mm dia 77 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 100 mm dia 78 Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. 79 INTERNAL HYDRANT 80 Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Gunmetal 81 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Gun Metal 82 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle.Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 30 m 83 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required Gun metal: 84 Fireman Axe-made of carbon steel with rubber insulated handle tested to 20,000 Volts as per IS:926 Make: NEWAGE 85 Fire shaft door fabricated out of M.S. sheet and frame, door size of 1200 (W) x 2100 (h)with 4 mm thick glass, suitable Rubber beading and Locking arrangement and complete door shall be powder coated with red color powder coating 86 Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 2 way-100 mm dia M.S. Pipe 87 SUBHEAD-II :FIRE EXTINGUSHER 88 Providing, storing, handling, shifting, installation, testing and commissioning of halon free portable fire Extinguishers as described below: Co2 type Fire Extinguisher 4.5 Kgs. Capacity, made from brand new seamless cylinder, as per IS: 7285 and CCE approval, fitted with Discharge hose and horn and wheel type valve with initial Charge as per IS: 15683:2018 specification, bearing ISI Mark & EIL approved. Make: SAFEX Capacity 4.5KG 89 Providing and fixing of ABC Power type fire extinguishers consisting of welded M.S. cylindrical body, squeeze lever discharge valve fitted with pressure indicating gauge internal discharge tube 30 cm long high pressure discharge hose, discharge nozzle, suspension bracket. Conforming to IS: 15683 finished externally with red enamel paint fixed to wall with brackets complete with internal charge. Capacity 6KG 90 Providing and fixing Fire related signages printed on photoluminescent U1000 aluminium sheet of 1.0 mm (+-10%) containing Lumigen II as base chemical, covered under UV stablized coating and of appropriate sizeincluding fixing on wall, door, ceiling etc. with proper clamps, hangers, cleats, anchor fasteners etc. complete in all respects as directed by Engineer-in-charge. 91 SUBHEAD-III : FIRE CONTROL PANELS 92 Supply & Erection of factory fabricated & wired metal clad dust and vermin proof mounting, M.S Channel Base with botom and top cable entreis Electrical control panelMCCBs (four Pole 36 KA with thermal magnatic release) switches and instrument chamber etc. complete in all respect. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter, Selector switches for ammeter and Voltmeter, instrument fuses current transformer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches enty boxes shall be complete with suitable cable end boxes reverse. The job includes the grounting of the board as per directions of Engineer-in-charge. All out goings of 100 Amp. and above will be provided with Amp. Metre, curent transformer and selector switches etc. and insurment fuse The switch board shall be fabicated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubical type switch board shall be of cat A & B only. Same as above item but following mountings. INCOMER:- 1 Nos. 100 Amps. 4P MCCB ( 35 KA) 1 Set phase indication lights (R, Y, B) 1 No. Volt Meter (digital type) with inbuilt VSS & control fuses.1 No. 0-100 Amp. Ammeter (digital type) with inbuilt ASSBUS BARS: 150 Amps. TP&N aluminium bus bars OUT GOINGS:-2 Nos.25 Amps. TPN MCB (10 KA) 93 Copper Power Cables, Solid Copper Conductor upto 6 sq. mm & Balance Stranded Copper, XLPE Insulated, Cores Laid Up, PVC Innersheathed, Unarmoured/Armoured (Glavanised wire for cables up to 10x1.5 sq. mm, 8x2.5 sq. mm, 2x10 sq. mm, 3x10 sq. mm, 4x6 sq. mm & balance all galvanised steel strip), Extruded PVC Type ST2 Outer Sheathed, 650/1100 V Grade as per IS 7098 4 Core X 10 sqmm. Aluminium Armoured 94 Supplying and making end termination with brass double compression gland and aluminium lugs for following size of XLPE insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. It should be complete as per specifications & directions of Engineer-in-charge. 4 Core X 10 sqmm. Aluminium Armoured 95 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required 96 6 C x 2.5 Sqmm 97 2 C x 2.5 Sqmm 98 Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 99 25 mm Conduit 100 32 mm Conduit 101 Supplying and installing following size of perforated pre-painted M.S.cabletrayswithperforationnotmorethan17.5%,in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 150 mm width x 50mm depth x 1.6 mm thickness. 102 INTERNAL, EXTERNAL PLUMBING WORKS & DRAIN (Part - C) 103 SANITARY INSTALLATIONS & C.P FITTINGS 104 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid 105 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require :White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps 106 Providing and fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 107 Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge 108 Providing and fixing stone slab table rubbed, edges rounded and polished of size 75x50cm deep and 1.8cm thick fixed in Urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1cement: 2coarse sand: 4graded stone aggregate 6mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade 109 Providing and fixing unplasticised PVC connection pipe with brass unions 45 cm length 15 mm nominal bore 110 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean & Wall moutain type W.C. of quality and make as approved by Engineer - in - charge. 111 Providing and fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS:8931 a) (15 mm nominal bore 112 Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. 113 Providing and fixing toilet paper holder : C.P. brass 114 Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. (For bath) .15 mm nominal bore 115 Providing and fixing C.P. brass shower rose with 15 or 20mm inlet : 150 mm diameter 116 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS: 8931. 15 mm nominal bore 117 Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. 118 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms 119 Upvc WASTE & VENT PIPES AND FITTINGS 120 Providing and fixing in floor and wall face Ringfit SWR PVC Conventional system for soil and waste water pipes conforming toType B including jointing with seal ring. (i) Double socketed pipes. 121 110mm dia SWR P.V.C. pipe 122 90mm dia SWR P.V.C. pipe 123 Cutting holes up to 15x15 cm in R.C.C. floors androofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof 124 Providing and fixingcPVC pipes complete with cPVCfittings and clamps, including cutting and making good walls etc. ( for wash basin waste ) 32mm dia nominal bore 125 Providing & fixing M.S. holder bat clamps of approved design to sand cast iron/centrifugally cast (Spun) iron S & S pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).Including cost of cutting holes & making good the walls etc.(a) for 100mm dia pipe. 126 Providing & fixingUPVC Coupler 127 a) 110 mm dia. 128 b)90 mm dia. 129 Providing and fixing trap of self cleansing design with screwed down or hinged grating with hopper complete, including cost of cutting and making good the walls and floors : (a) 100mm inlet & 90mm outlet. 130 Providing and fixin SWR PVC. 90° elbow withincluding fittings complete. 131 a) 110mm 132 b) 90mm 133 Providing and fixing 45° elbow withincluding fittings complete. 134 a) 110mm 135 b) 90mm 136 Providing and fixing SWR PVC T Band with access doorincluding fittings complete. 137 110x110x110mm 138 90x90x90mm 139 Providing and fixing SWR PVC Y including fittings complete. 140 110x110x110mm 141 90x90x90mm 142 Providing and fixing END CAP withincluding fittings complete. 143 a) 110mm 144 b) 90mm 145 Providing and fixingcast iron terminal guard. 146 110 mm 147 INTERNAL RAIN WATER DRAINAGE WORK 148 Providing and laying cement concrete 1:5:10(1 cement : 5 coarse sand : 10 graded stone aggregate 20mm nominal size)around P.V.C Soil and waste pipe including bed concrete as per standard design(embedded in the flooring / ground) 110 mm dia(SW pipe) 149 Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion. 110 mm 150 Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. 151 Coupler 110 mm 152 Bend 87.5 degree 110 mm Bend 153 Shoe (Plain) 110 mm Shoe 154 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 155 Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm 156 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete. 157 INTERNALWATER SUPPLY WORKS 158 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. 159 20mm dia nominal outer dia pipes 160 25mm dia nominal outer dia pipes 161 32mm dia nominal outer dia pipes 162 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe withclamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge..Internal work & external 163 20mm dianominal bore 164 25mm dianominal bore 165 32mm dia nominal bore 166 40mm dia nominal bore 167 Providing and fixing gun metal gate valve with wheel of approved quality. 168 20mm dia nominal bore 169 25mm dia nominal bore 170 32mm dia nominal bore 171 40mm dia nominal bore 172 EXTERNALSEWERAGE & RAIN WATERSYSTEM 173 Excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed, within a lead of 50m. All kinds of soil Pipes, cables etc. exceeding 80mm dia but not exceeding 300mm. 174 Providing, laying and jointing glazed stoneware pipes grade A with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. 100mm diameter 175 Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) all roundS.W. pipes including bed concrete as per standard design 100mm dia SW pipe 176 Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design : 150 mm.dia. RCCPipes 177 Providing and laying NonpressureNP 2 class (light duty) RCC pipe with collars jointed withstiffmixtureofcement mortar in the proportion of 1:2 (1cement : 2 finesand ) includingtestingof joints etc. complete. 150 mm.dia. RCCPipes 178 Providing and fixing square-mouth S.W. gully trap grade‘A’ complete with C.I. grating, brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 150 x 100 mm size P type With Sewer bricks conforming to IS : 4885 179 Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design. Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg).: With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 180 Extra for depth for manholes:With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 181 Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement:3 coarse sand :6graded stone aggregate 20 mm nominal size) as per standard design : With 20x20 mm square bar 182 EXTERNAL DRAIN 183 Earthworkinsurfaceexcavationnotexceeding30 cm indepth but exceeding 1.5m in width as well as 10 sq.m. on plan including getting out and disposal of excavated earth upto 50m and lift upto 1.5m, as directed by Engineer-in-Charge:All kind od soil. 0.30 m & Above 184 Providing and laying in posotion cement concrete of specifiedgrade excluding the cost of centering and shuttering - All workup to plinth level. 1:5:10 ( 1 cement : 5 coarse sand {zone-III} : 10 graded stone aggregate 40mm nominal size) 185 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) 186 Mild steel or iron work in plain work such as in R.C.C. or R.B. (when not included in an over all rates ) including bending for proper completion of the workand including supply of steel and its wastage , bends, hooks and authorised overlaps shall be measured up to floor two level. 187 Centering and shuttering including strutting, propping etc. and removal of form for foundation footing bases bo column etc for mass concrete etc. for mass concrete. 188 BORE WELL 189 External W/S arrangements with T.W. boring of 150 mm dia with 110 mm dia P.V.C. pipe assembly, 1.5 H.P. submersible pump including supply of all accessories starter, panel etc. & pipe arrangements etc . 190 6 PVC casing pipe of ISI mark. 191 P/ F 2 GI pipe (B) class. 192 Nylon mesh for filter. 193 Plastic dori. 194 Solvent cement. 195 6 End cap. 196 6 Submersible cap. 197 2 MS clamp (Heavy). 198 2 GI elbow. 199 2: X 6 GI nipple. 200 1.5 HP 9 Stage submersible pump of ISI mark with automatic panel. 201 2.5 sqm. Submersible cable. 202 Drilling charges for 6 dia tubewell. 203 Pea Gravel. 204 2 MS socket. 205 Cartage of material upto site. 206 INTERNAL ELECTRIFICATION WORK (Part - D) 207 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B 208 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 209 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 210 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 211 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 212 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 213 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 214 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 215 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 216 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 217 Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A C curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. 218 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 219 20 mm 220 25 mm 221 32 mm 222 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 223 Supplying and fixing brass batten/ angle holder including connection etc. as required. 224 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 225 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. 1 or 2 Module (75mmX75mm) 226 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 227 Telephone socket outlet 228 TV antenna socket outlet 229 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 1Pair 230 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable 231 Supplying and drawingCo axial TV cable, RG-6 grade, 0.7 mm solid copper conductor, shieldedwith fine tinned copper braid and protected with PVCsheathin the existing surface/recessed steel/PVC conduit as required. 232 Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required. 100 mm dia 233 Lighting Fixtures (Lights/Fans) : 234 Supply, Installation, Testing and commissioning of 1200 mm sweep BEE 5 star rated, ceilingfan with Brush Less Direct Current(BLDC) motor class of insulation:B, 3 nos blades, 30 cm long down rod, 2nos canopies shackle kit safety rope copper winding, Power factor not less than 0.9, service valur minimum 6.00, Air delivery min 210 Cum/Min, 350 RPM THD less than 10% remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts washers, temperature rise =75 degree C(max), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz single phase AC supply, earthing etc complete as required (i) BEE 5 Star rated-1200 mm sweep 235 Armoured Cables (Cable/Gland/Lug) : 236 Supplying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following size 237 size 10 sq mm x 2 core 238 size 10 sq mm x 4 core 239 size 16 sq mm x 4 core 240 size 35 sq mm x 3-1/2core 241 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm 242 Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required. 243 Upto 35 sq. mm 244 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. 245 Upto 35 sq. mm 246 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle) 247 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 248 2 X 10 sq. mm (19mm) 249 4 X 10 sq. mm (25mm) 250 4 X 16 sq. mm (28mm) 251 3½ X 25 sq. mm (28mm) 252 3½ X 35 sq. mm (32mm) 253 Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 25 sq. mm 254 Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 35 sq. mm 255 Earthing Work : 256 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 257 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 258 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 259 L.T. Switch Panel Board : DBs & MCBs : 260 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 261 Single pole 262 Triple pole and neutral 263 Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 264 40 A 265 63 A 266 Supplying and fixing following way, surface/recess mounting vertical type, 415V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link , earth bar, din bar for mounting MCBS but without MCBs and incomer as required 8 way(4+24) , Double door 267 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 268 8 way (4 + 24), Double door 269 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 270 Miscellaneous Items : 271 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep 272 Supply and Fixing of shock treatment chart.prescribedas per I.E. Rules.duly framed with glass and supported from back with hard board or shoft board with supply of all material ,labour,T&P for proper completion of work. 273 Supply and Laying of 1800*900*12mm thick chequerd rubber matting of tested quality. complete in all respect. as per I.E. Rules 274 S/F of hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16SWGM.S. sheet incorporating 10mm dia, M.S. round barduly bent for supporting fan hanger dully painted withred oxide and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting along with supply of all materials, labour T & P etc., for proper completion of work. 275 Non-Schedule Items 276 Supply & fixing of 300mm sweep ventilating (Medium Heavy Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Double ball bearing /Copper motor /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 70/85 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Speed : 900/1400 RPM. Complete in all respect. 277 Supply & Fixing of LAN socket outlet modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. Complete in all respect. 278 CCTV WORK (Part - E) 279 SITC of 2 MP Dome Camera, 1/2.8 Progressive CMOS, ICR, 1920x1080: 25fps(P) / 30fps(N), H.265+/ H265/ H.264+ & H.264, 3D DNR, BLC, IR range: up to 30m, DC12V & PoE, Support mobile monitoring 280 SITC of 2 MP Bullet Camera 1/2.8 Progressive CMOS, ICR, 1920x1080: 25fps(P) / 30fps(N), 2.8mm/F2.0 lens (4/6mm optional), H.265+/H265/H.264+ & H.264, IP67, DWDR, 3D DNR, BLC, IR range: up to 30m, DC12V & PoE,Support mobile monitoring 281 Supply, Installation, Testing & Commissioning of 24Channel Network Video Recorder with specifications as follow: Supported Image Format H.264+/H.264, H.265+/H.265, MPEG-4, JPEG, M-JPEG; Supported Image Resolution 1920x1080, 1,280 x 960, 960 x 720, 640 x 480, 320 x 240; Maximum Number of Cameras 32; RAID 5, 320MBps incoming bandwidth Camera Control Pan/Tilt, Zoom, Focus, Brightness, Preset position call and program (up to 256), Auto mode GUI REC/Playback Control REC, PLAY, Rev PLAY, Pause; Network Interface Camera port: 10Base-T / 100Base-TX Min 2x 8TB can be installed. Certification: UL, CE, BIS, FCC. 282 24 Port POE Switch ,Unmanaged PoE, 24 100M PoE, 1 1000M PoE, 1 1000M SFP, 250m Transmission, 6KV Surge Protection, 225W 283 SITC of 2U Rack with complete accessories. 284 Supply , Installtion , Testing and Comissioning of CAT6Apatch cord 3 feet for rack side switch to jack panel connectivity. Approved Makes:Belden/Siemon/Panduit/Derwiser/ Rit 285 SITC of 8 TB Survillance Hard Disk 286 Supply and laying of CAT 6 UTP cable 287 Supply and laying of 25mm dia PVC conduit including accessories. 288 SITC of 49 flat screen FHD professional LED suitable for 24x7 operation with remote control and wall mount unit/floor stand complete with making connection etc as per list of approved makes. 289 STREET POLE WITH LED LAMP & HIGH MAST (Part - F) 290 Supply & fixing of 6 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with Single Arm bracket 1 Mtr length in 1:2:4 RCC foundation bolt including the cost of foundation, excavation & back filling and Required T&P completee in all respect. 291 Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 80 Watt. Confirming to IP 66 Protection complete in all respect. 292 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole 293 Supplying,installation,testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required.3 output (1output per phase) and suitable for three phase supply 294 Supply & fixing of anticlimbing device fabricated from G.I.(flat) of 25 mm x 6mm size in a shape of ring of the pole size, having G.I. flat pointed fins of length 225 mm in 8 nos. including all the materials, labour, T&P and other material required for proper completion for work and to the satisfaction of Engineer-in-Charge. 295 Supply and fixing of decorative 8 to 16 Watt LED bollard luminaire with driver set confirming to IP 65 protection complete in all respect. CAT. - AAA 296 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc.Following size 297 size 6 sq mm x 3 core 298 size 10 sq mm x 4 core 299 size 25 sq mm x 3-1/2core 300 Supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheaththed, underground cable including rubber ring etc. complete in all respect. Thearmouring of the cable shall be properly connected with the earthas per direction of engineer -incharge.for cable 301 size 6 sq mm x 3 core 302 size 10 sq mm x 4 core 303 size 25 sq mm x 3-1/2core 304 Supply and fixing ofplain or pin type copper tin plated cable socket (lug) to cable leadsfor pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cable 305 size 6 sq mm 306 size 10 sq mm 307 size 25 sq mm 308 Earthing Work : 309 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required 310 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/submain wiring/ cable as required 311 D.G. SET 30 KVA (Part - G) 312 Supply, Installation, Testing & Commissioning of 03 phase volts 50 cycle per second 1500 RPM air cooled, diesel generating set complete with silent type DG canopy & limiting sound level to 75 dB (A) over a distance of one meter with engine, alternator aircooled. The engine shall be complete with flywheel to suit flexible coupling with guard, air cleaner, fuel pump, fuel day tank, variable speed governor, fuel filter, lube oil filter, battery charging generator, voltage regulator, 24 volt charged voltage regulator, capacity and instrument panel comparing switch with key, space heater, lube oil temperature gauge, lube oil pressure gauge, water temperature gauge, battery charging ammeter, safety control for low lube oil pressure and hightemperaturetripping.Supplying, installation, testing and commissioning of Silent Type DG Sets,AMF Panel, Bus Ducting/ Cables from DG Sets to Essential Panel, Synchronizing Panel where required, DG Set enclosure room sound insulation/ventilation/smoke exhaust as required, Earthing of DG Set system, control cabling, Fuel tank/piping, DG set Exhaust piping/Exhaust Chimney as per CPCB norms, Civil works connected with DG Sets including Foundation as required. DG Set Compatible for synchronising Panel30 KVA 313 Supply and fixing of M.S. Fencing frame duly fabricated from M.S. angle iron 50mm x 50mm x 5mm /40mm x 40mm x 5mm with M.S. flat 40 x 6 mm with M.S. welded 10 SWG, Mesh Jali best quality 25 x 25 mm on fencing frame with 6 Nos. M.S. Fasteners of required size duly painted complete in all respects. The Fencing frame of different sizes as site requirement. 314 Add Extra For RCC Foundation Work for D.G. Set Including Cost of Exaust Pipe with Structure and Other Misc. Work and T&P etc. Complete in all respect as per directed by Engineer In-Charge. 315 Earthing System : 316 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required 317 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 318 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as requiredide. 319 Boundary Wall & Entrance Gate (Part - H) 320 Earth work in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms, lifts up to 1.5 m. including getting out the excavated soil and disposal of surplus excavated soil within a lead of 50 m. - in ordinary soil . 321 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level. 1:4:8 (1 Cement : 4 coarse sand (zone-Ill) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 322 Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete 323 Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers 324 Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts 325 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana I Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate I retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.:N Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% ofthe specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum (M-25 up to plith level) 326 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana I Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate I retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.:N Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% ofthe specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg /cum (M-25 above plinth level) 327 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-5000 ormore. 328 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1 :6 (1 cement : 6 coarse sand) 329 Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in super structure above plinth level up to floor V level in : Cement mortar 1:6 (1 Cement : 6 coarse sand) 330 Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm). 331 Making Groove in plaster 10 to 12 mm wide x 8mm deep in plaster vertically or horizontally as required . 332 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 333 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work 334 Interlocking Tiles (Part - I) 335 Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per technical specification clause-401 336 Providing and Laying of interlocking concrete Block pavement having thicking 80 mm as per drawing and technical specification Clause 1504. (Exclusive G.S.B.)
Contract Date : Ref. Documents   |   Contract Value : Ref. Documents
Disclaimer

We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.

Tender Detail
Website https://etender.cpwd.gov.in/login.html
Quantity
MSME Exemption No
Tender Type Open Tender
Startup Exemption Click Here
Competitive Bidding NCB
Similar Tenders
TENDER INSIGHTS

858

Electric Tenders
Live
CLICK TO KNOW MAXIMUM WIN

Tell us about your Product / Services,

We will Find Tenders for you

🇮🇳 +91
TenderDetail
Loading tenders