TDR : 56317568
Gujarat Energy Transmission Corporation Limited

Tender Brief :

Surendranagar, Gujarat

Tender For Up keeping of Substation Bi-Annual Housekeeping/Up keeping/ cleaning work in control room and removal of grass/anti-weeding treatment in switchyard at 400 KV Pachham s/s under Limbdi TR Division

Published: 04 Jul 2026
Opening: Ref Document
Closing: 27 Jul 2026
Amount: 27.37 Lakhs
EMD: 40000
Tender Fee: 1180


Works Accounting Services Acoustical Work Advertising Agency Aerial Advertisement Agriculture service
15
Days Left
Tender Summary / Eligibility Criteria
Bi-Annual Housekeeping/Up keeping/ cleaning work in control room and removal of grass/anti-weeding treatment in switchyard at 400 KV Pachham s/s under Limbdi TR Division
Documents Download All
TBSTC932026
TBSTC932026.pdf
31537b217d714874978f028aee0aea61
31537b217d714874978f028aee0aea61.html
No Boq
No Corrigendum
Probable Bidders

AI engine predicts probable bidders to help you bid strategically.

MSME Exception
Explore More →
Technical
Tender involves procurement of high capacity electrical equipment including diaphragm coupling of pump & motor with 90kW capacity at 2900 RPM. The project scope includes installation, testing, commissioning and operational handover.
Previous / Similar Result
BRR : 7085545 Biennial contract for Round the clock routine, preventive & breakdown maintenance of entire Electrical System of Main Plant & Offset areas (BOP) excluding CHP along with engagement of electrical field operation assistance (Operator Shift) of 1x660 MW PTEP, Panki, Kanpur (UP).; 1 PART-A: MAINTENANCE OF HT MOTORS 2 12 WeeklyChecks (Quarterly PM) of HTmotors 3 HT MOTORS (>1500-2500 KW)-24 W Checks 4 HT MOTORS (>2500-5000 KW)-24 W Checks 5 HT MOTORS (>5000 KW)-24 W Checks 6 HT MOTORS Terminal connection/disconnection 7 Deployment of highly skilled manpower for unscheduled jobs 8 Deployment of skilled manpower for unscheduled jobs 9 Deployment of semi skilled manpower for unscheduled jobs 10 HT Motor weekly checks above 1500 KW 11 HT MOTORS (>1500-2500KW) Attend Defect/Servicing 12 HT MOTORS(>2500-5000 kW)-Attend Defect/Servicing 13 HT MOTORS(>5000 KW)-Attend Defect/Servicing 14 HT MOTORS (>1500-2500 KW) Shifting/rotation 15 HT MOTORS(>2500-5000 KW) Shifting/rotation 16 HT MOTORS(>5000 KW) Shifting/rotation 17 Circuit identification/labelling on panels/equipments by Painting background with two or more coats on new work with synthetic enamel paint of approved brand and manufacture to give an even shade and lettering with black japan paint of approved brand and manufacture 18 Painting of various types of panels/equipments 19 Part-B: HT SWITCHGEAR MAINTENANCE (11 KV) 20 PM of 11 KV Breakers 21 Maintenance of Power Busbar of 11 KV switchgear boards 22 Breakdown jobs and checking of HT breakers and HT switchgears, 23 Highly Skilled manpower deployment for unscheduled jobs 24 Skilled manpower deployment for unscheduled jobs 25 Semi Skilled manpower deployment for unscheduled jobs 26 Testing Engineer 27 PART-C: MAINTENANCE OF TRANSFORMER AND SWITCHYARD EQUIPMENTS 28 Routine checks of Switchyard Equipment 29 Antiweed Treatment & removal of grass from Switchyard 30 Troubleshooting of Switchyard Defects 31 Troubleshooting of SAS/SCADA System & BCUs/IEDs/Data Concentrator/BTS 32 Station Earthing System Checks 33 Routine checks of Transformers/Reactor rating more than 10 MVA 34 Routine checks of Transformers up to 10 MVA 35 Shutdown/Breakdown Maintenance of Transformer more than 10 MVA/Reactor 36 Preventive maintenance of Transformer upto 10 MVA 37 Breakdown maintenance of Transformer upto 10 MVA 38 Oil filtration of transformers/Reactor rating more than 10 MVA 39 Oil filtration of transformers rating up to 10 MVA 40 Oil Sample collection of transformers/Reactor 41 Shutdown/Breakdown Maintenance of Switchyard Equipments 42 Switchyard 400 KV Circuit Breaker Replacement 43 Circuit Breaker Drive Mechanism Replacement 44 Bushing Replacement of Transformer more than 10 MVA 45 Switchyard Isolator/Earth switch/CT/CVT/LA Replacement 46 Replacement of damaged ACSR Conductor 47 Replacement of damaged Clamp/Tightening of Clamp 48 House Keeping of Switchyard Control Room building 49 Painting of HT/LT Busducts, HT/LT Transformers, HT/LT Motors, and other electrical equipments, 50 PART-D: MAINTENANCE OF GENERATOR AND AUXILLIARIES 51 Assistance in Daily checking of Generator parameters and Upkeep of various panels of Generator & its auxiliaries including IP, SP, NSPBD, Air pressurization units, PT cubicles, CT & PT, Marshalling boxes, ECUP 52 Transportation/Loading/Unloading of H2 gas filling 53 Servicing/Overhauling ofpump of seal oil system as per scope of work 54 Servicing/Replacement of float trap valve as per scope of work 55 Servicing/Replacement ofvalves of H2 Gas/Seal Oil System/Primary Water System Valve as per scope of work 56 Removal of H2 gas from Generator as per scope of work 57 Filling of H2 gas in Generator as per scope of work 58 Alignment of Primary Water/Seal oil pumps with AC/DC motor as per standard procedure. 59 Replacement of AC/DC Seal Oil Pump as per scope of work. 60 Replacement of following by isolating & dismantling and assembling & installation after completion of work 61 Bearing of Seal oil pump 62 Mechanical Seal of seal oil pump. 63 Servicing /Overhauling/Bearing replacement of Primary Water Pump 64 Replacement/Cleaning ofSeal oil system duplex Filter 65 Replacement/Cleaning ofSWCS cooler Filter 66 Replacement of Resins 67 Servicing of Duplex filter of Seal oil system as per scope of work 68 Attending Leakage from Generator Gas coolers as per scope of work 69 Replacement of defective Generator Hydrogen Gas cooler 70 Detecting Hydrogen gas leakage with help of soap solution and attending minor gas leakage from entire generator system 71 Breakdown maintenance of Thyristor cooling fans 72 Replacement ofrubber expansion bellows of phase and neutral side of generator Terminal/Phase 73 Work on IP/NSPBD/SP bus ductsofUT/UAT/GT 74 Cleaning/replacement of flexible links of phase/neutralside, Main run, Delta run and TAP OFF run of generatorterminal as per scope of work 75 Replacement of phase/neutral side protection CT 76 Deployment of highly skilled manpower for unscheduled jobs 77 Deployment of skilled manpower for unscheduled jobs 78 Deployment of semi-skilled manpower for unscheduled jobs 79 PART-E: Engagement of Electrical Field Operation Assistant (Operator) Round the clock in Shift for two years for 11 KV and above 80 Shift Operator for Operation of Main Plant HT Switchgear, MCC rooms and DC battery room. 81 Shift Operator for Operation of Transformer and Switchyard area 82 PART-F: LIGHTING, WELDING AND CABLING NETWORK MAINTENANCE 83 Daily Routine and breakdown maintenance of lighting division 84 Laying of GI wire/strips 85 Laying of GI pipes and gi/pvc/flexible conduits 86 Battening/casing capping on wall 87 Laying of PVC flexible single core wires 88 Laying of power/control cables of dia upto 10 mm 89 Laying of power/control cables of dia above 10 mm and upto 40 mm 90 Laying of power/control cables of dia above 40 mm and upto 80 mm 91 Excavation of trench 92 Jointing and end termination of control cables of all sizes 93 Jointing and end termination of LT power cables of all sizes 94 Up-keeping of various cable galleries /trenches and racks 95 Circuit identification/labelling on panels/equipments by Painting background with two or more coats on new work with synthetic enamel paint of approved brand and manufacture to give an even shade and lettering with black japan paint of approved brand and manufacture 96 Fabrication & fixing of canopy (size up to 0.5 sq.mtr.) 97 Shift maintenance of lighting and welding network (consisting of one gang of one skilled electrician and one un-skilled helper) 98 Supplyingof following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. Size: 20 mm 99 Supplying follwing size of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required 100 2 x 2.5 sq. mm 101 2 x 4 sq. mm 102 Maintenance of light fittings and associated equipments 103 Maintenance of fans and associated fixtures 104 Overhauling of lighting panels 105 Maintenance of LED based aviation obstruction light fitting (up to 275 mtr height) 106 Installation of TL/GLS/CFL/LED/HPSV/Halogen lamp fittings (upto 70W) 107 Installation of HPSV/MH/LED lamp fittings (above 70W) 108 Installation of single phase office and industrial equiments 109 Jointing and end termination of HT power cables of all sizes 110 Painting of street light poles 111 Painting of various types of panels/equipments 112 Fabrication & fixing of canopy (size >0.5 sq.mtr. & up to 1 sq.mtr.) 113 Supplying of metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 114 Size: 200x125x60 mm 115 Size: 200x250x75 mm 116 Supplying of following switch/socket on the existing switch box/cover including connections etc. as required. 117 5/6 A switch 118 15/16 A switch 119 3 pin 5/6 A socket outlet 120 5 pin 15/16 A socket outlet 121 Supplyingfollowing rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. Rating: 25Amps 122 Supplyingfollowing rating, four pole, (three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 123 25 Amp 124 40 Amp 125 63 Amp 126 Supply and Fixing of 18/20 Watt 4 feet LED Batten Light of ISI marked reputed brand 127 PART-G : MAINTENANCE OF HT AND LT MOTORS (3.3 KV and below) 128 LT MOTOR (<=2.2 KW) Attend Defect 129 LT MOTOR (>2.2-5.5 KW) Attend Defect 130 LT MOTOR (>5.5-18.5 KW) Attend Defect 131 LT MOTOR (>18.5-37 KW) Attend Defect 132 LT MOTOR (>37-55 KW) Attend Defect 133 LT MOTOR (>55-90 KW) Attend Defect 134 LT MOTOR (>90 KW) Attend Defect 135 DC MOTORS(<=10 KW)-Attend Defect 136 DC MOTORS(>10-20 KW)-Attend Defect 137 DC MOTORS(>20 KW) Attend Defect 138 LT MOTOR (<=5.5 KW) Connection 139 LT MOTOR (>5.5-18.5 KW) Connection 140 LT MOTOR (>18.5-37 KW) Connection 141 LT MOTOR (>37-55 KW) Connection 142 LT MOTOR (>55-90 KW) Connection 143 LT MOTOR (>90 KW) Connection 144 12 WeeklyChecks (Quarterly PM) of HTmotors 145 HT MOTORS (<=1000 KW)-24 W Chks 146 HT MOTORS (>1000-1500 KW)-24 W Chks 147 HT MOTORS Terminal connection/disconnection 148 LT (AC and DC) MOTOR, ratings upto 200 KW, 12 Weekly Checks 149 LT (AC and DC) MOTOR, ratings upto 200 KW, 24 Weekly Checks 150 LT MOTOR (<=2.2 KW) OH/Servicing 151 LT MOTOR (>2.2-5.5 KW) OH/Servicing 152 LT MOTOR(>5.5-18.5 KW)- OH/Servicing 153 LT MOTOR(>18.5-37 KW)- OH/Servicing 154 LT MOTOR(>37-55 KW)- OH/Servicing 155 LT MOTOR(>55-90 KW)- OH/Servicing 156 LT MOTOR(>90 KW)- OH/Servicing 157 DC MOTORS(<=10 KW)- OH/Servicing 158 DC MOTORS(>10-20 KW)- OH/Servicing 159 DC MOTORS(>20 KW)- OH/Servicing 160 Deployment of highly skilled manpower for unscheduled jobs 161 Deployment of skilled manpower for unscheduled jobs 162 Deployment of semi skilled manpower for unscheduled jobs 163 HT Motor weekly checks upto 1500 KW 164 HT MOTORS (<=1000 KW) Attend Defect /Servicing 165 HT MOTORS (>1000-1500 KW) Attend Defect/Servicing 166 LT MOTOR (<=10 KW) Shifting/Replacement 167 LT MOTOR (>10- 30 KW) Shifting/Replacement 168 LT MOTOR (>30-75 KW) Shifting/Replacement 169 LT MOTOR (>75-90 KW) Shifting/Replacement 170 LT MOTOR (>90 KW) Shifting/Replacement 171 DC MOTORS(<=10 KW)-Shifting/Replacement 172 DC MOTORS(>10-30 KW)-Shifting/Replacement 173 DC MOTORS(>30 KW) Shifting/Replacement 174 HT MOTORS (<=1000 KW) Shifting/rotation 175 HT MOTORS (>1000-1500 KW) Shifting/rotation 176 Rewinding of 3-Phase 440V induction motor 177 Up to1.0 KW 178 Above 1.0 KW up to 5 KW 179 Above 5 KW up to 10 KW 180 Above 10 KW up to 20 KW 181 Above 20 KW up to 30 KW 182 Above 30 KW up to 40 KW 183 Above 40 KW up to 55 KW 184 Above 55 KW up to 70 KW 185 Above 70 KW up to 80 KW 186 Above 80 KW up to 100 KW 187 Above 100 KW up to 110 KW 188 Above 110 KW up to 135 KW 189 Above 135 KW up to 145 KW 190 Above 145 KW up to 200 KW 191 Rewinding of Single phase 240V AC induction motor Up to 1.0 KW 192 Rewinding of 220V DC Motor/Generator 193 Up to 1 KW 194 Above 1 KW up to 5 KW 195 Above 5 KW up to 20 KW 196 Above 20 KW up to 40 KW 197 Above 40 KW up to 60 KW 198 PART-H: LT AND HT SWITCHGEAR MAINTENANCE (3.3 KV and below) 199 PM of 3.3 KV Breakers 200 Maintenance of Power Busbar of 3.3 KV switchgear boards 201 Maintenance of Power and Control Busbar chambers of LT switchgear and MCC panels 202 PM All EOT (except TG hall) Attend defect 203 PM of Hoists and winches 204 PM of LT Modules 205 PM of LT Breakers 206 Breakdown jobs and checking of LT modules, LT breakers and switchgears, 207 Breakdown jobs and checking of HT breakers and HT switchgears, 208 Highly Skilled manpower deployment for unscheduled jobs 209 Skilled manpower deployment for unscheduled jobs 210 Semi Skilled manpower deployment for unscheduled jobs 211 PM of DC motor starter panels 212 Breakdown jobs of DC motor starter panels 213 PM of Local Control Panels, ACDBs, DCDB etc., 214 PM of EOT crane of TG hall 215 EOT crane of TG hall - attend Defects 216 Hoists and winches-attend Defect 217 Shift Electrical Maintenance (2x3x365) 218 Cleaning of Electrical panels, modules, motors, and Local Control panels 219 Testing Engineer 220 PART-I: MAINTENANCE OF DC SYSTEM AND DG SETS 221 Capacity test of Battery Banks 222 Assistance in detection and rectification of Earth faults in DC systems 223 Replacement of defective Cells 224 Monitoring healthiness and maintenance of Battery Bank 225 PART-J: MAINTENANCE OF ESP & ASSOCIATED EQUIPMENTS 226 Arresting of oil leakage from high voltage rectifier transformer 227 Checking, Cleaning and inspection of ESP area electrical equipments 228 Annual Preventive & Break-down maintenance of ESP fields/Tr panels 229 Annual Preventive & breakdown maintenance of ESP rectifier transformers 230 Oil filtration of Rectifier Transformer of ESP 231 Cleaning and Inspection of High Voltage rectifier transformer 232 Deployment of highly skilled manpower for unscheduled jobs 233 Skilled manpower deployment for unscheduled jobs 234 Semi Skilled manpower deployment for unscheduled jobs 235 Replacement of damaged with New/repaired ESP transformer along with negative bushing chamber by dismentalling,lowering down, shifting, lifting up & recommissioning and associated works and connecting it to field 236 PART-K: Engagement of Electrical Field Operation Assistant (Operator) Round the clock in Shift for two years for upto 3.3 KV 237 Shift Operator for Operation of Main Plant MV, LV Switchgear, MCC rooms and DC battery room 238 Shift Operator for Operation of MV, LV Switchgear, MCC room of ESP & FGD 239 Shift Operator for Operation of MV, LV Switchgear, MCC room ofW & WWTP 240 Shift Operator for Operation of MV, LV Switchgear, MCC room of AHP
Contract Date : 21 Mar, 2025   |   Contract Value : 4.99 Crore
BRR : 1825522 Annual Maintenance Contract ( For 33Kv / 6.6 Kv Ht Switchyard, Substation Equipment ) ( Arc Items ) For Electrical Works And General Cp / Psp / Mov Related Works At Erpl Patna Pump Station-2 Complete Quarterly Manintenance Of 33 Kv / 6.6 Kv Ht Switchyard Equipments, Substation Equipments, Pump Station Equipments / Area, Under Erpl Patna Station Jurisdiction As Defined In Scope Of Work & Technical Specifications. List Of Equipments Are As Follows:- ( A ) Transformer & Ngr ( B ) Circuit Breaker ( Vcb ) ( C ) Air Circuit Breaker ( Acb ) ( D ) Current Transformer ( E ) Potential Transformer ( F ) Isolatorswitch ( G ) Earth Switch ( H ) Lightning Arrestor ( I ) Post Insulator ( J ) Protection System Of Entire Electrical System ( K ) Capacitor Bank ( L ) Mov Actuatorrates Will Be Inclusive Of Boarding, Lodging, Local Conveyance, Mobilization & Demobilization, Manpower, Equipment, Tools & Tackles And All Other Incidental Cost. 3 Complete Half Yearly Manintenance Of 33 Kv / 6.6 Kv Ht Switchyard Equipments, Substation Equipments, Pump Station Equipments / Area, Under Erpl Patna Station Jurisdiction As Defined In Scope Of Work & Technical Specifications. List Of Equipments Are As Follows:- ( A ) Transformer & Ngr ( B ) Circuit Breaker ( Vcb ) ( C ) Air Circuit Breaker ( Acb ) ( D ) Current Transformer ( E ) Potential Transformer ( F ) Isolatorswitch ( G ) Earth Switch ( H ) Lightning Arrestor ( I ) Post Insulator ( J ) Protection System Of Entire Electrical System ( K ) Capacitor Bank ( L ) Mov Actuatorrates Will Be Inclusive Of Boarding, Lodging, Local Conveyance, Mobilization & Demobilization, Manpower, Equipment, Tools & Tackles And All Other Incidental Cost. 4 Complete Yearlymanintenance Of 33 Kv / 6.6 Kv Ht Switchyard Equipments, Substation Equipments, Pump Station Equipments / Area, Under Erpl Patna Station Jurisdiction As Defined In Scope Of Work & Technical Specifications. List Of Equipments Are As Follows:- ( A ) Transformer & Ngr ( B ) Circuit Breaker ( Vcb ) ( C ) Air Circuit Breaker ( Acb ) ( D ) Current Transformer ( E ) Potential Transformer ( F ) Isolatorswitch ( G ) Earth Switch ( H ) Lightning Arrestor ( I ) Post Insulator ( J ) Protection System Of Entire Electrical System ( K ) Capacitor Bank ( L ) Mov Actuatorrates Will Be Inclusive Of Boarding, Lodging, Local Conveyance, Mobilization & Demobilization, Manpower, Equipment, Tools & Tackles And All Other Incidental Cost. 5 Relay Coordination, Testing And Calibration ( Relay Calibrator Being Used For The Work Should Be Calibrated By An Nabl Authorized Agency ) Of All Relays As Defined In Scope Of Work & Technical Specifications To Be Done Once In A Year. ( 1 Unit Of This Item Constitutes 138 Relays Listed In Scope Of Work & Technical Specifications ) . These 138 Relays Constitute Of Numerical Relays And Electromagnetic Relays ( Mostly Contact Multiplier Like K86, Tc Supn, Transformer Aux, Etc ) Rates Will Be Inclusive Of Boarding, Lodging, Local Conveyance, Mobilization & Demobilization, Manpower, Equipment, Tools & Tackles And All Other Incidental Cost. Work Schedule Will Be As Per Instruction Of Site Engineer / Eic. 6 Testing And Calibration ( Meter Calibrator Being Used For The Work Should Be Calibrated By An Nabl Authorized Agency ) Of All Meters As Defined In Scope Of Work & Technical Specifications To Be Done Once In A Year. ( 1 Unit Of This Item Constitutes 165 Meters Listed In Scope Of Work & Technical Specifications ) .Rates Will Be Inclusive Of Boarding, Lodging, Local Conveyance, Mobilization & Demobilization, Manpower, Equipment, Tools & Tackles And All Other Incidental Cost. Work Schedule Will Be As Per Instruction Of Site Engineer / Eic. 7 Testing And Calibration ( Through Nabl Certified Laboratory ) Of All Electrical Measuring Instruments As Defined In Scope Of Work & Technical Specifications To Be Done Once In A Year. ( 1 Unit Of This Item Constitutes 10 Measuring Instruments Listed In Scope Of Work & Technical Specifications ) . Rates Will Be Inclusive Of Boarding, Lodging, Local Conveyance, Mobilization & Demobilization, Manpower, Equipment, Tools & Tackles And All Other Incidental Cost. Work Schedule Will Be As Per Instruction Of Site Engineer / Eic. 8 Routine Breakdown Visit As Defined In Scope Of Work & Technical Specifications.Routine Breakdown Maintenance Means Identifying Reason For Malfunction / Not Working / Not Running Of Electrical Equipment On S Witching ( As Per Instruction Of Eic ) , By A Team Of ( 1+1 ) Engineer + Assistants, In Time Schedule Given By Engineer In Charge ( Quantity Of Routine Breakdown Maintenance Will Be Number Of Days As Per Schedule By Eic, Considering 8 Working Hours Per Day ) Rates Will Be Inclusive Of Boarding, Lodging, Local Conveyance, Mobilization & Demobilization, Manpower, Equipment, Tools & Tackles And All Other Incidental Cost. 9 Minor Breakdown Manintenance As Defined In Scope Of Work & Technical Specifications. Minor Faults In The Installed Items Are Where No Major Breakdown Has Occurred. In Minor Breakdown Maintenance, System Is To Be Stabilized In Maximum Duration Of 12 Working Hours From The Time Of Instruction By Se / Eic And Shall Mean A Team Of ( 1+4 ) Engineer + Assistants. Rates Will Be Inclusive Of Boarding, Lodging, Local Conveyance, Mobilization & Demobilization, Manpower, Equipment, Tools & Tackles And All Other Incidental Cost. Work Schedule Will Be As Per Instruction Of Site Engineer / Eic. 10 Major Breakdown Manintenance As Defined In Scope Of Work & Technical Specifications.Work Shall Be Termed As Major Breakdown, If Items Such As Crane, Specialized Lifting Equipment, Highly Skilled Man-Power Deputation, Major Spares Replacements, Etc. Are Required. [ Spare Shall Be Given By Iocl Or Extra Payment Shall Be Made For This ] , In This, System Is To Be Stabilized In Time Schedule Given By Engineer In Charge. Rates Will Be Inclusive Of Boarding, Lodging, Local Conveyance, Mobilization & Demobilization, Manpower, Equipment, Tools & Tackles And All Other Incidental Cost. 11 Attending Power Failure To System In Cp / Rcp / Mov Station As Defined In Scope Of Work & Technical Specifications. Stations Have Lt Power Supply Controlled By Mcb / Contactor. Restoration After Power Failure / Supply Interruption To The Input Terminal Of Main System Installed, Is Only In Scope Of This Work. Power Failure Or Interruption Issue Is To Be Attended By ( Restoring Supply ) / ( Bypassing Inverter ) Within 6 Hours ( From The Time Of Instruction By Se / Eic ) . In Case Of Fault In Inverter / Battery / Battery Charger, It Must Be Repaired And Reinstalled In Station Within 72 Hours ( From The Time Of Instruction By Se / Eic ) [ Cost Of Any Part Replacement Will Be Paid Extra ] . Contractor Has To Arrange For Repairing Of Inverter / Battery / Battery Chargerrates Will Be Inclusive Of Boarding, Lodging, Local Conveyance, Mobilization & Demobilization, Manpower, Equipment, Tools & Tackles And All Other Incidental Cost. Work Schedule Will Be As Per Instruction Of Site Engineer / Eic. 12 Service Assistance For Psp Checking, Inspecting Proper Functioning Of Lights And Exhaust Fans, Refilling Distilled Water In Batteries, Cleaning Of Solar Panels, Checking Fence Energizer, Checking Earth Pit & Anode Bed Condition, Checking System Functionality, Upkeeping Of Jbs, Cleaning Trenches And Earth Pits, Greasing And Painting Of Rusted Parts In Cp Stations Complete In All Respectunder The Supervision Of Iocl Personnel As Per Direction Of E-I-C. Contractor Has To Arrange Distilled Water & Lodgingarrangement For The Worker On His Own Expense. One Personnel Of Contractor May Commute Withiocl Personnel In Office Vehicle During Cp / Rcp / Sv Station Visits, But He Has To Reach To Vehicle Start Point And Return From Vehicle End Point At His Own Expense. All Required Material, Tools & Tackles, Equipment Is To Be Arranged By Contractor.Rates Will Be Inclusive Of Boarding, Lodging, Local Conveyance, Mobilization & Demobilization, Manpower, Equipment, Tools & Tackles And All Other Incidental Cost. Work Schedule Will Be As Per Instruction Of Site Engineer / Eic. 1 Unit Is For 1 Cp Station. [ Maintenance Of 2 Cp Stations Shall Require 1 Semiskilled Manday ] 13 Service Assistance For Psp Survey ( During Day Period ) Including Greasing Of Psp Connection, Carrying Measuring Instruments To Tlp Site, Bolting Of Tlp Post Door, Cleaning Of Tlps And Clearing Nearby Vegetations Complete In All Respect Including All Tools & Tackles And Consumables Under The Supervision Of Iocl Personnel As Per Direction Of E-I-C. Contractor Has To Arrange Lodging Of His Worker On His Own Expense. One Personnel Of Contractor May Commute Withiocl Personnel In Office Vehicle During Psp In Row, But He Has To Reach To Vehicle Start Point And Return From Vehicle End Point At His Own Expense. All Required Material, Tools & Tackles, Equipment Is To Be Arranged By Contractor. For Psp Measurement, Iocl Meters Will Be Used. Rates Will Be Inclusive Of Boarding, Lodging, Local Conveyance, Mobilization & Demobilization, Manpower, Equipment, Tools & Tackles And All Other Incidental Cost. Work Schedule Will Be As Per Instruction Of Site Engineer / Eic.1 Unit Is For Psp Survey Of All Pipelines In 1 Km Of Row. [ Psp Survey Of All Pipelines In 10Km Shall Require 1 Semiskilled Manday ] 14 Service Assistance For Mov / Pcv Actuator Maintenance. Actuators Are Of Make Biffi, Rotork And Auma. Assistance In Mov Actuator Maintenance, Complete In All Respect Under The Supervision Of Iocl Personnel As Per Direction Of Eic. Rates Will Be Inclusive Of Boarding, Lodging, Local Conveyance, Mobilization & Demobilization, Manpower, Equipment, Tools & Tackles And All Other Incidental Cost. Work Schedule Will Be As Per Instruction Of Site Engineer / Eic.1 Unit Is For 1 Mov Actuator Maintenance. Maintenance Of 10 Mov Actuator Shall Require 1 Semiskilled Manday ] 15 Filtration Of Transformer Oil By Stream Line Filter Machine Provided By The Contractor For Improving The Insulation Strength Of Oil To The Required Strength As Per Specification Given Below ( Excluding The Supply Of Oil ) . A ) Filtration Of Transformer Oil Till Bdv As Per Instruction Of Eic Is Attained. B ) Topping Up Of Oil. C ) Releasing All The Air From Air Release Plug & Bucholz Relay. D ) To And Fro Transportation Of Filter Machine And Equipments. E ) Conducting Transformer Oil Tests As Mentioned In Scope Of Work. 16 Electrical Composite Items 17 Caution Board 18 Supply And Install Caution Boards For Switchyard Voltage System As Per Iss-2551-1963 Complete In English / Hindi / Local Language. 19 Earthing Plate 20 Supply & Installation Of G.I. Earthing Plate Outside The Buildings. The Item Also Includes Grouting Of The Plate. The Item Should Be Complete In All Respect Including All Materials, Tools, Tackels Etc. And As Per Direction Of Eic / Site Engineer. 21 Earth Strip / Wire / Rope / Cable - Supply, Installing And Testing Of Earthing Strip / Wire / Rope / Cable For Completely Making The Earthing Grid System By Supplying, Laying The Gi / Cu Strip And Making All The Necessary Welding Joints, Connecting To The Earthing Electrodes And Existing Earthing Grid Etc., Complete As Per Directions Of The Site Engineer / Engineer-In-Charge, Including The Cost Of All Labour, Tools, Materials, Etc. Complete In All Respect: 22 50 Mm X 6 Mm G.I. Earthing Strip 23 40 Mm X 5 Mm G.I. Earthing Strip 24 25Mm X 4 Mm Copper Flat 25 25Mm X 3 Mm Copper Flat 26 Gi Wire ( 8 Swg ) 27 Gi Wire / Rope 35 Sq. Mm 28 Gi Wire / Rope 10 Mm Diameter 29 Copper Cable As Per Specifications - 100 Sq.Mm 30 Copper Cable As Per Specifications - 10 Sq.Mm 31 Earthing Grid ( Gi Strip ) : Supply, Installation And Testing Of 75 Mm X 10 Mm Gi Earthing Strip For Completely Making The Earthing Grid System By Supplying, Laying The G.I. Strip And Making All The Necessary Welding Joints, Connecting To The Earthing Electrodes And Existing Earthing Grid Etc. Complete In All Respects Including Consumables, Tools / Equipments And Labour As Per Directions Of Engineer-In-Charge / Site Engineer. 32 Earthing Electrode 33 Supplying, Installation, Testing Of Gi Earthing Electrode Including The Supply And Installation Of The G.I. Cover, Charcoal Etc. Complete In All Respects Including Consummables, Tools / Equipments And Labour As Per Directions Of Engineer-In-Charge / Site Engineer. 34 Pvc Conduit Pipes - Supply, Installation, Fixing In Position, Pvc Conduit Pipes, Of Isi Marked , In Concrete, Brick Work Etc. During Or After Construction By Making Grooves In The Wall, Ceiling Etc. Cutting Threads And Jointing The Pipes With Pvc Couplers, Providing Necessary Tees, Bends, Junction Boxes Etc. With 12 Swg Gi Wire Inside Conduit Without Joint For Concealed Wiring, Including Making Good The Concrete, Brick Work, Surfaces Etc. Complete As Per Direction Of Site Engineer / Engineer-In-Charge Including Cost Of All Labour, Materials Etc.: 35 19 Mm 36 25 Mm 37 32 Mm 38 Supply & Fixing Of Pvc Conduit On Surface: Supply And Fixing Of Following Size Of Pvc Conduit Along With The Accessories In Surface Including Cutting The Wal Land Making Good The Same In Case Of Reessed, Conduit As Required: Note: Only Isi Marked Conduits Shall Be Used. 39 20 Mm 40 25 Mm 41 32 Mm 42 40 Mm 43 50 Mm 44 Supply & Fixing Of Pvc Casing / Caping: Providing And Fixing Following Size Of Pvc Casing And Capingon Surface As Required. Note: Only Isi Marked Caping And Casing Shall Be Used. 45 15 Mm X 10 Mm 46 20 Mm X 10 Mm 47 25 Mm X 10 Mm 48 30 Mm X 10 Mm 49 40 Mm X 20 Mm 50 50 Mm X 20 Mm 51 Supply & Fixing Chequered Plates 52 Supply, Installation And Fixing Of Ms Chequered Plates Of 5Mm Thickness. Job Includes Cutting To Size, Supply Of Hinges / Hooks For Lifting, Tag Welding With Support Wherever Required, Painting Including Supply Of Paint, Supply Of All Material And Labor Complete In All Respect 53 Hard Stone Laying ( Sw Yard ) : Providing And Spreading 40Mm Size Approved Hard Stone Chips Around Transformer Yard In One Layer Of 100Mm Thick. Job Includes Dressing Of Soil Surface And Laying The Aggregate In Uniform Laying And Density As Per Direction Of Site Engineer Aggregate Shall Be Measured In Boxes Of Size 1.1 / 2M X 1.1 / 2M X 1.1 / 2M Which Shall Be Taken As 1M3. The Boxes Will Be Supplied By Contractor Free Of Charge For Measuring Purpose. 54 Supply Of 40Mm Size Stone Chips Per M3 55 Spreading The Stone Chips Per M3 56 Putty Application 57 Application Of Pvc Putty / M-Seal Putty On Lighting Fixtures / Jn. Boxes / Glands / Switch Boards Etc. To Avoid Entering Water / Insects / Any Other Type Of Things As Per Direction Of The Engineer-In-Charge. Note: Putty Will Be Supplied By Owner Free Of Cost. 58 Supplying And Fixing Of Gi Route Marker 59 Suppplying Cable Route Marker With 10 Cm X 10 Cm X 5 Mm Thick Gi Plate With Inscription Thereon, Bolted / Welded To 35 Mm X 35 Mm X 6 Mm Angle Iron, 60Cm Long And Fixing The Same In Ground As Required. Job Includes Painting With One Coat Of Redoxide And Finishing Paint. 60 33Kv ( E ) / 22 Kv ( Ue ) Heat Shrinkable Straight Through Pvc / Xlpe Armoured Aluminium Cable Jointing ( Including Cost Of Jointing Kit ) : Making Straight Through Cable Joint For Power ( Pvc / Xlpe ) Armoured Cable And Following Sizes And Grade Including Cutting, Stripping Of Cable Insulation All Complete With Labour Including Travel, Transportation, Boarding And Lodging Of The Cable Jointer And Materials Excluding Cost Of Jointing Kit As Per Standard And Direction Of The Engineer-In-Charge. Note: Work To Be Done In Timeline As Mentioned In Tender Document. 61 3 X 400 Sqmm 62 Salt And Charcoal For Plate Earthing: Extra For Using Below Given Salt And Charcoal For Plate Earthelectrode As Required. 63 96 Kg Charcoal And 5 Kg Salt 64 240 Kg Coke And 5 Kg Salt 65 Salt And Charcoal For Pipe Earthing: Extra For Using Below Given Salt And Charcoal For Pipe Earth Electrode As Required. 66 64 Kg Charcoal And 5 Kg Salt 67 160 Kg Coke And 5 Kg Salt 68 Provide First-Aid Boxes 69 Supply And Fixing Of First-Aid Boxes As Per Ie Rules, 1956 Clause 43 ( 2 ) , Including Necessary Clamps, Bolts, Rawl Plugs, Etc. Breachking And Making Good The Walls If Required. All Complete With Labour And Materials As Per The Direction Of Engineer-In-Charg 70 Fire Buckets 71 Supply And Installation Of Set Of 3 Nos. Fire Buckets On A Suitable Stand Including Fabrication And Erection Of Iron Stand And Painting Of Stand And Buckets, All Complete With Labour And Materials As Per The Direction Of Engineer-In- Charge 72 Providing And Fixing Following Rating Metal Clad, Tp&N Switch Fuse Unit, 415 / 500 Volts, Without H.R.C. Fuses Including Drilling Holes On The Board, Connections, Earthing The Body Etc. As Required. 1.Isi Marked Hrc Fuses Shall Be Used. 2.Tpn Of English Electric / L&T / Crompton / Havells / Standard Make Shall Be Used. 73 16 A Tpn Hrc Sfu 74 32 A Tpn Hrc Sfu 75 63 A Tpn Hrc Sfu 76 100 A Tpn Hrc Sfu 77 L Series Mcb Suitable For Lighting And Other Domestic Loads: Supplying And Fixing Of Following Rating 240 Volts, 50Hz, 10Ka L Series, Miniature Circuit Breacker ( Suitable For Lighting And Other Domestic Loads And Conforming To Is 8828: 19 ) Of Single Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Note: Isi Marked Mcbs Of Havells / Loadster / Indo Kopp Make Shall Be Used. 78 5 To 32 Amp 79 40 Amp 80 5 A To 32 A G Series Mcb Suitable For Motorl And Other Inductive Loads: Supplying And Fixing 5 Amps. To 32 Amps. Rating, 240 / 415 Volts, 50Hz, 10Ka G Series, Miniature Circuit Breaker ( Suitable For Motor And Other Inductive Loads And Conforming To Is 8828: 1996, Iec 60898: 2002 ) Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Note: Isi Marked Mcbs Of Havells / Loadster / Indo Kopp Make Shall Be Used. 81 Single Pole 82 Single Pole And Neutral 83 Double Pole 84 Triple Pole 85 Triple Pole And Netural 86 Four Pole 87 40 A To 63 A G Series Mcb Suitable For Motorl And Other Inductive Loads: Supplying And Fixing 40 Amps. To 63 Amps. Rating, 240 / 415 Volts, 50Hz, 10Ka G Series, Miniature Circuit Breaker ( Suitable For Motor And Other Inductive Loads And Conforming To Is 8828: 1996, Iec 60898: 2002 ) Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Note: Isi Marked Mcbs Of Havells / Loadster / Indo Kopp Make Shall Be Used. 88 Single Pole And Neutral 89 Double Pole 90 Triple Pole And Netural / 4 Pole 91 Sp & Dp Mcb Isolator: Supplying And Fixing Following Rating, Single Pole & Double Pole Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Note: Isi Marked Isolators Shall Be Used. 92 40 Amps. Single Pole 93 63 Amps. Single Pole 94 40 Amps. Double Pole 95 63 Amps. Double Pole 96 80 Amps. Double Pole 97 100 Amps. Double Pole 98 125 Amps. Double Pole 99 Tp & Fp Mcb Isolator: Supplying And Fixing Following Rating, Three Pole And Four Pole, 415 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Note: Isi Marked Isolators Shall Be Used. 100 40 Amps. Triple Pole 101 63 Amps. Triple Pole 102 80 Amps. Triple Pole 103 100 Amps. Triple Pole 104 125 Amps. Triple Pole 105 40 Amps. Four Pole 106 63 Amps. Four Pole 107 80 Amps. Four Pole 108 100 Amps. Four Pole 109 125 Amps. Four Pole 110 Double Pole Rccb: Supplying And Fixing Following Rating, Double Pole, ( Single Phase Neutral ) , 240 Volts, Residual Current Circuit Breaker ( Rccb ) , Isi Marked, Having A Sensitivity Current Indicated Miliamperes In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Note: Isi Marked Rccb Shall Be Used. 111 16 Amps., 30 Ma 112 16 Amps., 100 Ma 113 16 Amps., 300 Ma 114 25 Amps., 30 Ma 115 25 Amps., 100 Ma 116 25 Amps., 300 Ma 117 32 Amps., 30 Ma 118 32 Amps., 100 Ma 119 32 Amps., 300 Ma 120 40 Amps., 30 Ma 121 40 Amps., 100 Ma 122 40 Amps., 300 Ma 123 63 Amps., 30 Ma 124 63 Amps., 100 Ma 125 63 Amps., 300 Ma 126 Four Pole Rccb: Supplying And Fixing Following Rating, Four Pole, ( Three Phase And Neutral ) 415 Volts, Residual Current Circuit Breaker ( Rccb ) , Isi Marked, Having A Sensitivity Current Upto Indicated Milliamperes In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Note: Isi Marked Rccb Shall Be Used 127 25 Amps., 30 Ma 128 25 Amps., 100 Ma 129 25 Amps., 300 Ma 130 40 Amps., 30 Ma 131 40 Amps., 100 Ma 132 40 Amps., 300 Ma 133 63 Amps., 30 Ma 134 63 Amps., 100 Ma 135 63 Amps., 300 Ma 136 Supply & Instln. Of Fuse Parts: Supply, Fixing And Connection Of Following Knife Type Hrc Fuse Link As Per Is:13703:1993 & Iec 269:1986 Of M / S Havell / L&T / G Ec Astholm / Standard / Mds Make Or Approved Equivalent In Distribution Board Etc.All Complete With Labour And Materials As Per Direction Of Engineer-InCharge. 137 Knife Type 6-100 Amp ( Fcd00 Series ) 138 Knife Type 125 Amp ( Hcd00 Series ) 139 Knife Type 32-125 Amp ( Hcd-1 Series ) 140 Bolted Type 2-32 Amp ( Hns Series ) 141 Boltedtype 6-32 Amp ( Htia Series ) 142 Boltedtype 80-125Amp ( Htsd Series ) 143 Supply And Fixing Of Equipment In Panels: Supply, Fixing And Connection Of Following Equipments In Panels Including Small Mechanical Works And Supply Of All Fixing Materials. All Complete With Labour And Materials As Per The Direction Of Engineer-In-Charge 144 Control Contactors- 4 Contacts For Ac Control Standard Coil Voltage - 25, 110, 240, 415, 50Hz Type Mm00 Of L&T Equivalent 145 Control Contactors- 8 Contacts For Ac Control Standard Coil Voltage - 25, 110, 240, 415, 50Hz Type Mm01 Of L&T Equivalent 146 Control Contactors- 4 Contacts For Dc Control Standard Coil Voltage - 24, 110, 220 Type Mm00 Of L&T Or Equivalent 147 Control Contactors- 4 Contacts For Dc Control Standard Coil Voltage - 24, 110, 220 Type Mm01 Of L&T Or Equivalent 148 Power Contactor ( With 1No + 1Nc ) - Upto 25 Amp ( Ac3 ) For Ac Standard Coil Voltage - 110, 220, 240, 415 V, 50Hz Type Mnx25 Of L&T Or Equivalent 149 Power Contactor ( Upto 2No + 2 Nc ) - Above 25 Amp But Upto 45 Amp ( Ac3 ) For Ac Standard Coil Voltage - 110, 220, 240, 415 V, 50Hz Type Mnx45 Of L&T Or Equivalent 150 Power Contactor ( Upto 2No + 2 Nc ) - Above 45 Amp But Upto 140 Amp ( Ac3 ) For Ac Standard Coil Voltage - 110, 220, 240, 415 V, 50Hz Type Mnx140 Of L&T Or Equivalent 151 Power Contactor ( Upto 2No + 2 Nc ) - Above 140 Amp But Upto 400 Amp ( Ac3 ) For Ac Standard Coil Voltage -110, 220, 240, 415 V, 50Hz Type Mnx400 Of L&T Or Equivalent 152 Thermal Relays Type Mnxr3 With Single Phasing Protection - 0.2 - 0.33 A To 14 -23A ( Direct Operated ) 153 Thermal Relays Type Mnxr4 With Single Phasing Protection - 20-33 To 30.0 - 50.0 A ( Direct Operated ) 154 Thermal Relays Type Mnxr4 With Single Phasing Protection -45-75 To 66-110 A ( Direct Operated ) With Separate Mounting 155 Thermal Relays Type Mnxr5l With Single Phasing Protection - 42 - 69 A To 180 - 300 A ( Ct Operated ) With Separate Mounting 156 Thermal Relays Type Ml0 / Ml1 / Ml1.5 - 0.15 - 0.25 A To 10.0 - 16.0 A ( Direct Operated ) Contractor 157 Thermal Relays Type Ml2 / Ml3 - 9.0 - 14.0 A To 28.0 - 42.0 A ( Direct Operated ) Contractor 158 Shrouded Push Button Actuator Of L&T Make Tk-3 ( Ss 91519 ) Or Approved Equivalent Of Any Color ( Green, Black, Red, Yellow, Grey Or Blue ) . 159 Automatic Ac Ammeter ( Automatic Electric Make Or Approved Equivalent ) 96 Mm X 96 Mm Square Type Block Backalite Case / Flush Mounting / Moving Iron / Spring Controlled Suppressed Scale, Ct Operated Ac Ammeter / Range 0-300- 1800 A, Ct Ratio 300 / Ia / Accuracy + / -2.5%. 160 Automatic Ac Volt Meter ( Automatic Electric Make Or Approved Equivalent ) 96 Mm X 96 Mm Square Type Block Backalite Case / Flush Mounting Ac Volt Meter / Range 0-600 Accuracy + / -2.5%. 161 Installation Of Current Transformer Of Any Rating 162 Timer For Auto Lux Switch 163 Supply And Installation Of Timer Of Approved Make For Autolux Switch As Per Secpfication And Direction Of The Engineer-In-Charge 164 Rcbo: Supply, Fixing And Connection Of Following 240 / 415V, 50Hz, With 10Ka Short Circuit Capacity Residual Current Circuit Breaker With Overload And Short Circuit Protection ( Confirming To Is 12640-2:2001 & Iec 61009-2-1 ) Of L&T / Gec Astholm / Standard / Mds / Datar / Havles Make Or Approved Equivalent In Distribution Board Etc. All Complete With Labour And Materials As Per Direction Of E-I- C 165 Double Pole ( Four Module - 25 A ( Sensitivity 30 Ma ) 166 Double Pole ( Four Module - 25 A ( Sensitivity 100 Ma ) 167 Double Pole ( Four Module - 25 A ( Sensitivity 300 Ma ) 168 Double Pole ( Four Module - 40 A ( Sensitivity 30 Ma ) 169 Double Pole ( Four Module - 40 A ( Sensitivity 100 Ma ) 170 Double Pole ( Four Module - 40 A ( Sensitivity 300 Ma ) 171 Supply & Installation Of Mccb: Supply & Installation Of M / S L&T / English Electric / Siemens Make T.P. Molded Case Circuit Breaker ( Mccb ) ( Confirming To Is 8828:1996, Iec 60898:2002 ) Of Following Current And Breaking Capacity Rating Suitable For 415V, 3Ph, 50 C / S Ac Supply Must Be Accompanied With Performance Test Certificates From Manufacturer. The Mccb Should Be Supplied With Thermal Overload Relay And Magnetic Release. 172 10 / 15 / 20 / 30 / 40 / 50 / 60 / 63 / 75 / 90 / 100 A With Icu = 10Ka 173 110 / 125 / 140 / 150 A With Icu = 10Ka 174 125 / 140 / 150 / 160 / 175 / 200 / 225 A With Icu = 25Ka 175 250 / 300 / 350 / 400 A With Icu = 35Ka 176 Supply & Installation Of Led Indication Lamps: Supply And Fixing Of Led Indication Lamp In The Panels. Leds Shall Be Provided With Leakage Voltage Protection Upto 40V. Operating Voltage Shall Be 110V / 220V / 230V / Ac / Dc, Panel Cutouts Shall Be 22.5 / 25.5 / 30.5 Mm. Terminals Shall Be Shrouded For Finger Proofing And Safety Are With Captivated Washers To Hold Two Lugged ( Fork / Pin ) Wires In One Terminal. Job Includes Supply Of Labor And Various Undry Materials Required And Finally Testing Of LedS For + Following EdS 177 Red / Yellow / Amber / Green / Milky White LedS 178 Blue Led 179 Supply & Instln. Of Industerial Type Plug And Sockets : Supply, Fixing And Connection Of Following Inusterial Type Plugs / Sockets ( Confirming To Is / Iec-309 ) Of M / S Havell / L&T / G Ec Astholm / Standard / Mds Make Or Approved Equivalent In Distribution Board Etc.All Complete With Labour And Materials As Per Direction Of Engineer-In-Charge 180 Plug- 2 Pole+ Earth, 250V- 20 Amp 181 Plug- 3 Pole+ Earth, 440V- 20 Amp 182 Socket- 2 Pole+ Earth, 250V- 20 Amp 183 Socket- 3 Pole+ Earth, 440V- 20 Amp 184 Supply And Fixing Of Recessedmetal Boxes With Phenolic Sheet: Supply And Fixing Of Metal Box Of Following Size ( Nominal ) In Recess With Suitable Size Of Phenolic Laminated Sheet Cover In The Front Including Painting Etc. As Required. 185 75 Mm X 75 Mm X 60 Mm Deep 186 100 Mm X 100 Mm X 60 Mm Deep 187 150 Mm X 75 Mm X 60 Mm Deep 188 150 Mm X 150 Mm X 60 Mm Deep 189 180 Mm X 100 Mm X 60 Mm Deep 190 200 Mm X 125 Mm X 60 Mm Deep 191 200 Mm X 150 Mm X 60 Mm Deep 192 200 Mm X 150 Mm X 75 Mm Deep 193 200 Mm X 250 Mm X 75 Mm Deep 194 200 Mm X 150 Mm X 100 Mm Deep 195 Gi Cable Tray 196 Supply, Installation & Fixing Of Prefabricated Perforated Gi Cable Trays With Tray Cover Of Width 150 Mm, 300 Mm, 450 Mm & 600 Mm As Per Site Requirement For Laying Of Cables With Standard Rung Spacings. Load For Support Span Of 2.5 Meter As 30, 60, 75 & 90 ( In Kg / Mtr ) Respectively With Concentric Static Load As 70 Kg At The Centre, With Materials, Labour, Tools And Tackles, Consumables Etc , As Per Directions Of Site Engineer / Engineer-In-Charge. 197 Aluminium Cable Tray 198 Supply, Installation & Fixing Of Prefabricated Perforated Aluminium Cable Trays With Tray Cover Of Width 150 Mm, 300 Mm, 450 Mm & 600 Mm As Per Site Requirement For Laying Of Cables With Standard Rung Spacings. Load For Support Span Of 2.5 Meter As 30, 60, 75 & 90 ( In Kg / Mtr ) Respectively With Concentric Static Load As 70 Kg At The Centre, With Materials, Labour, Tools And Tackles, Consumables Etc , As Per Directions Of Site Engineer / Engineer-In-Charge. 199 Supply Erection And Installation Of Cable Conduits Made Up Of Gi Pipes Of Medium Class, Subject To OwnerS Approval, In Already Made Trenches, On Walls, Concrete Structures Etc. Including Supply And Installation Of All The Necessary Pipe Fittings Such As Bends, Sockets, Elbows, Tees, Etc. The Job Also Includes Bending, Threading, Binding, Clamping, Providing Spacere, Plugs, Packings, Bushing Etc. As Required For Laying Of Cables, Complete In All Respects Including Consumables, Tools / Equipments And Labour A Per Directions Of Engieer-In-Charge / Site Engineer. 200 Gi Pipe With Diameter 20 Mm 201 Gi Pipe With Diameter 25 Mm 202 Gi Pipe With Diameter 37 Mm 203 Gi Pipe With Diameter 100 Mm 204 Ht Cable Termination ( 6.6 / 11 Kv ) - Supply, Termination And Connection Of Xlpe Cable Termination Kit ( Indoor Type ) , Heat Shrinkable Sleeve Type Of Raychem / M-Seal / Cci Make With All Accessories, Including Cutting ( Tools And Accessories For Termination Should Meet The Selected Standards ) , Stripping Of Cable Insulation Providing Copper Cable End Lugs And Cable Glands As Required, Restoration Of Insulation, Supplying And Providing The Cable Supporting Clamps, Straps, Cable Tags Connection To The Terminals Of Ht Panel, Vfds, Isolators, Transformer, Dg, Mlpu / Booster Pump Motors Etc., Earthing Of Armouring, Materials, Labour, Tools And Tackles, Consumables Etc , As Per Directions Of Site Engineer / Engineer-In-Charge: 205 Ht Cable Of Size Above 3Cx240 Sq. Mm 206 Ht Cable Of Size Upto 3Cx240 Sq. Mm 207 Lt Cable End Termination For Armoured Pvc Insulated Aluminium Cable With Doublecompression Flame Proof Type Brass Glanding ( Including Cost Of Glands & Lugs ) : Providing End Termination Of Power / Control Cable Including Cutting, Stripping, Providing & Fixing Lugs, Cable Insulation, Providing & Glanding Double Compression Heavy Duty Flame Proof Type Brass Cable Gland Conforming To Is-12943 ( DowellS Or Approved Equivalent ) , Wherever Specified, Providing Aluminium Lugs, Crimping / Soldering, As Necessary, Restoration Of Insulation / Clamping Of Cable, Tagging With Aluminium Tag, Earthing Of Armour, Connection To The Equipment Terminals Etc. All Complete With Labour And Materials As Per Standard And Direction Of The Engineer-Incharge 208 2 X 6 Sqmm 209 2 X10sqmm 210 2 X16sqmm 211 3 X 4 Sqmm 212 3 X 6 Sqmm 213 3 X 10 Sqmm 214 3 X 16 Sqmm 215 3 X 25 Sqmm 216 3 X 35 Sqmm 217 3 X 50 Sqmm 218 3 X 70 Sqmm 219 3 X 95 Sqmm 220 3 X 120 Sqmm 221 3 X 150 Sqmm 222 3 X 185 Sqmm 223 3 X 225 Sqmm 224 3 X 240 Sqmm 225 3 X 300 Sqmm 226 3-1 / 2 X 25 Sqmm 227 3-1 / 2 X 35 Sqmm 228 3-1 / 2 X 50 Sqmm 229 3-1 / 2 X 70 Sqmm 230 3-1 / 2 X 95 Sqmm 231 3-1 / 2 X 120 Sqmm 232 3-1 / 2 X 150 Sqmm 233 3-1 / 2 X 185 Sqmm 234 3-1 / 2 X 225 Sqmm 235 3-1 / 2 X 240 Sqmm 236 3-1 / 2 X 300 Sqmm 237 Lt Cable Heat Shrinkable Indoor / Outdoor Cable End Termination ( Including Cost Ofend Termination Kit ) : Providing End Termination Of Power Cable Including Cutting, Stripping, Providing Lugs, Cable Insulation, Providing And Glanding With Single / Double Compression Heavy Duty Brass Cable Gland Conforming To Is-12943 , Wherever Specified, Providing Aluminium Lugs, Crimping / Soldering, As Necessary, Restoration Of Insulation / Clamping Of Cable, Tagging With Aluminium Tag, Earthing Of Armour, Connection To The Equipment Terminals Etc. All Complete With Labour And Materials As Per Standard And Direction Of The Engineer-In-Charge. Make Of Kits Shall Be Of Raychem / Cci / Approved Equivalent Make 238 Upto 3 / 3.5 / 4 X 10 Sqmm 239 3 / 3.5 / 4 X 16 Sqmm 240 3 / 3.5 / 4 X 25 Sqmm 241 3 / 3.5 / 4 X 35 Sqmm 242 3 / 3.5 / 4 X 50 Sqmm 243 3 / 3.5 / 4 X 70 Sqmm 244 3 / 3.5 / 4 X 95 Sqmm 245 3 / 3.5 / 4 X 120 Sqmm 246 3 / 3.5 / 4 X 150 Sqmm 247 3 / 3.5 / 4 X 185 Sqmm 248 3 / 3.5 / 4 X 225 Sqmm 249 3 / 3.5 / 4 X 240 Sqmm 250 3 / 3.5 / 4 X 300 Sqmm 251 Ht Cable Joint 252 Making Straight-Through Joint On 6.6 / 11 Kv Aluminium / Copper Xlpe / Pvc Insulated Armoured Screened Cable, Including The Supply Of Required Materials Such As Cable Jointing Kit ( Of Heat Shrinkable Sleeve Type Of Raychem / M-Seal / 3M ) , Materials, Labour, Tools And Tackles, Consumables Etc , As Per Directions Of Site Engineer / Engineer-In-Charge: For Cables Of Size Upto 3 Core X 400 Sqmm 253 Lt Cable Joint ( 1.1 Kv ) - Making Straight Through Joints On Al / Cu Conductor Xlpe / Pvc Insulated Armoured Cable Including The Supply Of Required Materials Such As Cable Jointing Kit ( Of Heat Shrinkable Sleeve Type Of Raychem / Mseal / 3M ) , Materials, Labour, Tools And Tackles, Consumables Etc , As Per Directions Of Site Engineer / Engineer-In-Charge: 254 Power Cables Lt : Od Upto 20 Mm 255 Power Cables Lt : Od Above 20 Mm And Upto 40 Mm 256 Power Cables Lt : Od Above 40 Mm And Upto 60 Mm 257 Power Cables Lt : Od Above 60 Mm 258 Control Cables Lt : Od Upto 20 Mm 259 Earthing System Set ( 06 Pits ) 260 Supply, Installation, Testing Of Earthing System Consisting Of 6 Earth Pits Of Perforated Gi Pipes Earthing Electrodes And Copper Plate Terminal Block Including Construction Of Chamber Using Cement Concrete With Earthing Pit Cover And Frame, Supply Of Charcoal, Salt Etc Including Supply Of Interconnecting Cables / Strips Including Necessary Welding Etc Complete As Per Directions Of The Site Engineer, Including Cost Of Tools, Materials Etc Complete In All Respects. The Job Shall Also Include Testing Of Each Earth Pit And The Entire Earthing System On Whole. ( Note: Earthing For Field Instruments Shall Be Provided From Station Earth Grid Covered In Electrical Sor. ) 261 Earthing System Set ( 03 Pits ) 262 Supply, Installation, Testing Of Earthing System Consisting Of 3 Earth Pits Of Perforated Gi Pipes Earthing Electrodes And Copper Plate Terminal Block Including Construction Of Chamber Using Cement Concrete With Earthing Pit Cover And Frame, Supply Of Charcoal, Salt Etc Including Supply Of Interconnecting Cables / Strips Including Necessary Welding Etc Complete As Per Directions Of The Site Engineer, Including Cost Of Tools, Materials Etc Complete In All Respects. The Job Shall Also Include Testing Of Each Earth Pit And The Entire Earthing System On Whole. ( Note: Earthing For Field Instruments Shall Be Provided From Station Earth Grid Covered In Electrical Sor. ) 263 Chemical Earthpit 264 Supply, Installation, Testing And Commissioning Of Ace ( Artificial Concept Of Earthing With Chemical Rod ) Chemrod Earthing Electrode By Digging Earthing Item Includes The Supply And Installation Of The Ci / Rcc Cover In The Earth Pit, Backfilling Etc. And Construction Of Chamber; Complete Including Excavation, Backfilling And Supply Of All Materials Required For Making Earth Pit As Per Directions Of The Site Engineer, Including The Cost Of All Labour, Tools, Materials Etc. Complete In All Respects. 265 Lightining Arrestor 266 Supply, Installation And Testing Of Lightning Arrestor On Top Of The Mov Buiding Or Mov Cp Buiding For Diverting Lightning Surges To The Ground. The Work Shall Include Supply Of 1.2 Meter Long Copper Lightning Arrestor With 5 Spronged Phenyl Rod Base Plate Etc. Complete With Necessary Insulators Including Supply And Fixing Of 50 X 6 Mm Gi Earthing Strip Of Required Length And Connection To The Main Earthing Grid. 267 Rewiinding Of Fans: Rewinding Of Ceiling / Pedestal / Exhaust / Air Circulator Fans Of All Types / Sizes / Make Including 1-Phase And 3-Phase Type Exhaust Fans Max. Upto 2.2 Kw Capacity And Supply Of Super Enameled Winding Wire ( Devi Dayal Make, Isi Marked Insulation Materials Required ) . This Also Includes Replacement Of Single / Double Bearing Skf Make / Bushes ( As Per Original Make ) And Overhauling Of Fan And All Jobs Related To Complete This Work In Totality. This Also Includes Removal Of Fans From Site, Installation And Commissioning After Testing Of Rewound Fans And Replacement Of Condenser, If Required. This Also Includes Transportation From Site After Dismantling To Contractor’S Workshop And Back To Site. Note: Contractor Has To Give Guarantee For Rewinding Of Above Items For A Period Of Six Months And If Winding Is Burnt Again Within Six Months Of Working Of Fans, It Has To Be Rewound Again Free Of Cost Of Contractor. The Burnt Winding Shall Be Kept By Contractor. 268 Ceiling / Pedestal Fans 269 Exhaust / Air Circulators Fans. 270 Overhauling Of Exhaust / Air Circulator Fans : Overhauling Of Exhaust / Air Circulator Fans Of Various Types / Sizes Makes And Its Bearings Including Removal From Site, Cleaning, Greasing After Degreasing, Assembling And Fixing In Position, Testing And Commissioning Including Transportation From Site To Workplace And Back All Complete With Labour And Materials As Per Directions Of Engineer-InCharge. 271 Excluding The Cost Of Bearings ( Bearings If Necessary Will 272 Including Supply And Fixing Of Bearings Of Skf Make ( 2Nos. Bearings ) 273 Overhauling Of Ceiling / Pedestal Fans : Overhauling Of Ceiling / Pedestal Fans Of Various Types / Sizes / Make And Its Bearings Including Removal From Site, Cleaning, Greasing After Degreasing, Assembling And Fixing In Position, Testing And Commissioning Including Transportation From Site To Workplace And Back. All Complete With Labour And Materials As Per Directions Of Engineer-InCharge. 274 Excluding The Cost Of Bearings. ( Bearings If Necessary Will Be Supplied By Owner Free Of Cost. 275 Including Supply And Fixing Of Bearings Of Skf Make And Bushes ( As Per Original Make ) Of Both Sides By Contractor. 276 Erection Of Metallic Street Light: Erection Of Metallic Steet Light Standard Of Following Length In Cement Concrete 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 40 Mm Nominal Size ) Foundation With Cement Concrete Collar Of Size 0.4 M Dia X 0.5 M Height To Accommodate The Looping Type Cable End Box Including Excavation And Refilling Etc. As Required. 277 4.5 M But Upto 6.5 M 278 6.5 M But Upto 8 M 279 Supply, Erection And Installation Of Strain Insulators, Post Insulators, Acsr Dog Conductor, Connectors, Shield Wire, Etc For Outdoor Switchyard. The Job Also Includes Assembling As Required, Installation On Already Made Concrete Foundations Or Fixing To Walls Or Steel Structures Or Fixtures, Aligning, Levelling, Groutting Assembling And Fittings All Accessories Etc. Supplied Separately, Complete In All Respects Including Consumables Tools / Equipments And Labour As Per Directions Of Engieer-In-Charge / Site Engineer. 280 Strain Insulators For 33 Kv 281 Acsr Dog Conductors For 33 Kv 282 Connectors For 33 Kv 283 Shield Wire For 33 Kv 284 Post Insulators For 33 Kv 285 Supply And Fixing Of Street Light Bracket With Controlling Switch 286 Supplying And Fixing Of 20Mm Dia. G.I. Pipe For Street Light Water Tight Bracket Including Bending To Shape, 40Mm X 3Mm Flat Iron Clamps And Wiring With 1.5 Sq.Mm. W.P. / Pvc Wire Alongwith Water Proof Controlling Switch And Painting The Flat Iron With Primer And Finish Paint Etc. As Required. 287 33 Kv Stay Set 288 Supplying And Erection Of Galvanised Stay Set For 33 Kv Overhead Line Complete With 19 / 20Mm. Dia X 1.8 Metres Long Stay Road, Anchor Plate Of Size 45 Mm X 45 Cm X 7.5 Mm Thick Thimble, Stay Clamps, Turn Buckle ( 20Mm X 600Mm ) , 7 / 4.00Mm. Dia G.I. Stay Wire And 33 Kv Strain Insulator Etc. In Cement Concrete 136 ( 1 Cement 3 Coarse Sand 6 Graded Stone Aggregate 40Mm. Nominal Size ) Foundation Including Excavation And Refilling Etc. As Required. 289 Louvers / Shutters Of Exhaust Fan 290 Fixing Of Louvers / Shutters Complete With Frame For Exhaust Fan Of All Sizes 291 Supplying And Fixing Ceiling Fan: Supply, Installation, Testing & Commissioning Of Ceiling Fans Of Bajaj / Crompton Greaves / Khaitan / Usha Make Only Including Supply And Fixing Of The Electronic Regulators With All Necessary Supports. All Complete With Labour And Material, Specification And Direction Of Engineer In Charge 292 1200Mm Sweep ( White ) 293 1400Mm Sweep ( White ) 294 Supplying And Fixing Wall Mounted Fan: Supply, Installation, Testing And Commissioning Of Wall Mounted Fans Of Bajaj / Cromptonreaves / Khaitan / Usha Make Only Including Supply And Fixing Of The Electronic Regulators With All Necessary Supports. All Complete With Labour And Materials As Per Directions Of Engineer-In-Charge.. Note: Necessary Civil Works Required For Fixing The Exhaust Fans Shall Be In The Scope Of Contractor. 295 Osc. Wall & Cabin Fans Of 300Mm Sweep 296 Osc. Wall & Cabin Fans Of 450Mm Sweep 297 Steel Structural Works 298 Supply, Fabrication, Erection, Installation Of Steel Structural Works Of Any Type And Shape Such As Cable Raks, Cable Trays, Push Button Control Posts Etc., As Required Job Complete In All Respects Including The Cost Of All Labour, Tools, Material Etc., Complete.And As Per Specifications And Directions Of Site Engineer / Engineer-In-Charge. 299 Flp / Wp Push Button Station - Supply , Erection, Testing And Commissioning Of Flp / Wp Push Button ( On / Off ) Control Station Of Approved Make With / Without Ammeter For The Motor Off Control At Field Including Connection And Termination Of Copper Control Cable, Fabricating, Earthing The Supporting Structure, Painting The Same, Including Supply & Installation Of Double Compression Cable Glands & Flame Proof Plugs For Sealing All Spare Entries Including The Cost Of All Labour, Tools, Materials Etc. Complete In Every Respect As Per The Specification And Directions Of The Site Engineer / Engineer-In-Charge Including The Cost Of All Labour, Tools, Materials Etc. Complete In Every Respect As Per The Specification And Directions Of The Site Engineer / Engineer-In-Charge: 300 With Ammeter 301 Without Ammeter 302 Flame Proof Fittings - All Equipment Under This Category Shall Be Suitable ( Minimum Requirments ) For Location In Zone-I Gas Group Iia & Iib ( Temp. Class T3 ) Area With A Separate Terminal Box For Incoming Cable And A Separate Terminal Box For Out Going Cable ( Where Applicable ) , Apart From Separate Enclosure For Each Equipment Including Control Gear Etc. In Ip 65 Cast Aluminium Lm-6 Certified Enclosure: 303 Flameproof Tubelight, 2X22watt, Led, Suitable For Exd Gas Group Ii C, As Per Is / Iec 60079-2007 304 Flameproof Led Well Glass Fitting 90 W, Supply, Installation, Testing & Commissioning Of ExD ( Flameproof ) Well Glass Light Fixture With Provision Of Cable Entries: 2 Nos. X 3 / 4 Et, Cable Glands: 2 Nos. X 3 / 4 Et ( Max. Od 20Mm ) - ExD ( Iia / Iib ) , Double Compression Type, Brass Nickel Plated With Pvc Hood. Blanking Plug: 1 No. X 3 / 4 Et - ExD, Brass Nickel Plated. Gasket: Neoprene, Hardware: Ss 304, Earthing: External 2 Nos. ( M6 ) , Internal 1 No. ( M5 ) , And As Per Directions Of Eic. 305 Flameproof Led Flood Light Fitting 90 W, Supply, Installation, Testing & Commissioning Of ExD ( Flameproof ) Flood Light Fixture With Provision Of Cable Entries: 2 Nos. X 3 / 4 Et, Cable Glands: 2 Nos. X 3 / 4 Et ( Max. Od 20Mm ) - ExD ( Iia / Iib ) , Double Compression Type, Brass Nickel Plated With Pvc Hood. Blanking Plug: 1 No. X 3 / 4 Et - ExD, Brass Nickel Plated. Gasket: Neoprene, Hardware: Ss 304, Earthing: External 2 Nos. ( M6 ) , Internal 1 No. ( M5 ) , And As Per Directions Of Eic. 306 Flameproof Led Flood Light Fitting 45 W, Supply, Installation, Testing & Commissioning Of ExD ( Flameproof ) Flood Light Fixture With Provision Of Cable Entries: 2 Nos. X 3 / 4 Et, Cable Glands: 2 Nos. X 3 / 4 Et ( Max. Od 20Mm ) - ExD ( Iia / Iib ) , Double Compression Type, Brass Nickel Plated With Pvc Hood. Blanking Plug: 1 No. X 3 / 4 Et - ExD, Brass Nickel Plated. Gasket: Neoprene, Hardware: Ss 304, Earthing: External 2 Nos. ( M6 ) , Internal 1 No. ( M5 ) , And As Per Directions Of Eic. 307 Flameproof Led Well Glass Fitting 125 W, Supply, Installation, Testing & Commissioning Of ExD ( Flameproof ) Well Glass Light Fixture With Provision Of Cable Entries: 2 Nos. X 3 / 4 Et, Cable Glands: 2 Nos. X 3 / 4 Et ( Max. Od 20Mm ) - ExD ( Iia / Iib ) , Double Compression Type, Brass Nickel Plated With Pvc Hood. Blanking Plug: 1 No. X 3 / 4 Et - ExD, Brass Nickel Plated. Gasket: Neoprene, Hardware: Ss 304, Earthing: External 2 Nos. ( M6 ) , Internal 1 No. ( M5 ) , And As Per Directions Of Eic. 308 Critical Light: Flame Proof & Weather Proof Supply, Erection ( Fixing The Same On Roof Truss, Wall, Column Etc. As Required ) , Termination Of 240V, Flame Proof Light Fittings With Heat Resistant Glass Diffuser And Suitable For Led Lamp, Ip65, Of Model Pel 111 Prolite Make Or Equivalent Approved Makes As Per Eic. The Job Includes The Cost Of Fitting And Erection 1 No. Led Lamp 18W, Ni-Cd Battery Of Suitable Size For Minimum 01 Hour Back Up, Battery Charger, Earthing, Supply & Erection Of All Accessories, Suitable Ms Brackets Etc. Complete. 309 Flp & Wp Junction Box - Supply, Erection, Installation, Testing And Commissioning Of Flameproof & Weather Proof Junction Box For Providing Cable Termination Of Motor, Including Connection And Termination Of Earthing Wire And Conduits Etc., Including Supply & Installation Of Double Compression Cable Glands & Flame Proof Plugs For Sealing All Spare Entries Complete As Per Direction Of The Site Engineer, Including The Cost Of All Labour, Tools, Consumable Materials Etc., Complete In All Respect: 310 8 Way Junction Box With 8 Cable Entries ( 1 X 1 & 7 X 3 / 4 ) At Bottom & 20 Nos. Terminals. 311 6 Way Junction Box With 6 Cable Entries ( 6 X 3 / 4 ) At Bottom & 20 Nos. Terminals. 312 4 Way Junction Box With 4 Cable Entries ( 4 X 3 / 4 ) At Bottom & 20 Nos. Terminals. 313 Exhaust Fan - Supply, Installation, Testing Of Single Phase 230 V, Industrial Type Heavy Duty Exhaust Fan Of Gec / Usha / Crompton Greaves Or Of Approved Make Fitted / Provided With Louvres, Supports Etc. Including Making The Required Opening On Walls, Fixing And Connecting The Wires Etc. Including Earthing The Body Of The Fan, Making Good The Opening On The Wall Etc. Complete As Per Direction Of Site Engineer Including The Cost Of All Labour, Tools, Materials Etc. Complete. 314 18 Sweep 315 12 Sweep 316 Flp / Wp Exhaust Fans: 317 Flame Proof, Weather Proof, Single Phase, 12 Exhaust Fan, Ip65, Lm6 Type Ef1001 Of Fcg Or Equivalent Alongwith Supporting Frame, Bolts, Louvers, Flame Proof Motor, Including Supply & Installation Of Double Compression Cable Glands & Flame Proof Plugs For Sealing All Spare Entries, Complete In All Respects 318 Flame Proof, Weather Proof, Single Phase, 12 Exhaust Fan, Suitable For Exd Gas Group Ii C, As Per Is / Iec 60079-2007, Ip65, Lm6 Type Ef1001 Of Fcg Or Equivalent Alongwith Supporting Frame, Bolts, Louvers, Flame Proof Motor, Including Supply & Installation Of Double Compression Cable Glands & Flame Proof Plugs For Sealing All Spare Entries, Complete In All Respects 319 Flp / Wp Rotary Switch: 320 Supply, Installation, Testing & Commissioning Of Flame Proof Weather Proof On / Off Rotary Switch , Ip65, Lm6, Including Including Supply & Installation Of Double Compression Cable Glands & Flame Proof Plugs For Sealing All Spare Entries Etc., Complete In All Respects. 321 Flp / Wp Distribution Boards - Supply, Erection, Installation, Testing And Commissioning Of Flameproof / Weather Proof ( Ip-65 ) Distribution Board As Per Technical Specification Of Types As Per Eic For Lighting Purpose In Mlpu / Booster Shed Etc., Including Connection And Termination Of Power Cables, Earthing Wire And Conduits Etc. Including Including Supply & Installation Of Double Compression Cable Glands & Flame Proof Plugs For Sealing All Spare Entriescomplete As Per Direction Of The Site Engineer, Including The Cost Of All Labour, Tools, Consumable Materials Etc. Complete In All Respect: 322 Outdoor Type, Floor Mounted, Flameproof, Weatherproof ( Ip 65 ) Lighting Distribution Board Type-I Db With Bus Bar - 100 A Tpn, Incomer - 1 No. 63 A Tpn Mcb & Outgoing - 9 No. 10 A Spn, Mcb 323 Outdoor Type, Floor Mounted, Flameproof, Weatherproof ( Ip 65 ) Lighting Distribution Board Type-Ii Db Having Bus Bar - 100 A Tpn, Incomer - 1 No. 32 A Tpn Mcb & Outgoing - 3 No. 6 A Spn Mcb 324 Flp / Wp Switch Cum Socket - Supply, Erection, Installation, Testing And Commissioning Of Flameproof / Weatherproof Switch Cum Socket / Welding Receptacle Of Approved Makes To Be Installed On Walls, Coloumns, Structures, Including Supply & Installation Of Double Compression Cable Glands & Flame Proof Plugs For Sealing All Spare Entries Etc., Including Connection And Termination Of Earthing Wire And Conduits., Etc. Complete As Per Direction Of The Site Engineer, Including The Cost Of All Labour, Tools, Consumable Materials Etc. Complete In All Respect: 325 250V, 15 A Switch Cum Socket With Plug 326 250V, 63 A Plug & Welding Receptacle 327 415V, 63A, Switch & Socket With Plug ( No. Of Pins 3P +N+ E ) , Model Epss 1563-61 Of Baliga Or Equivalent Approved Make 328 Wp 6 Way Junction Box: 329 Supply, Erection, Installation, Testing And Commissioning Of Weather Proof 6 Way Junction Box Of Approved Make For Providing Cable Termination & Including Connection And Termination Of Earthing Wire And Conduits, Including Supply & Installation Of Cable Glands & Plugs For Sealing All Spare Entries Etc. Complete As Per Direction Of The Site Engineer, Including The Cost Of All Labour, Tools, Consumable Materials Etc. Complete In All Respect. 330 Wp Push Button Station: 331 Supply, Erection, Testing And Commissioning Of Weather Proof Push Button ( Off ) Control Station Of Approved Make For Emergency Transformer Tripping At Field Including Connection And Termination Of Copper Control Cable, Fabricating, Earthing The Supporting Structure, Painting The Same, Including Supply & Installation Of Cable Glands & Plugs For Sealing All Spare Entries Including The Cost Of All Labour , Tools, Materials Etc. Complete In Every Respect As Per The Specification And Directions Of The Engineer-In-Charge. 332 Stainless Steel Inscription Plate : 333 Supply And Installation Of Approved Quality Stainless Steel Name Inscription Plates Including Anodising, Engraving The Inscriptions, Providing Screws, Etc. For Equipments Viz. Motors, Motor Control Centres, Switchgears, Push Button Stations Etc. As Required, Providing Necessary Holes Tapping Etc. And Fixing The Same Complete In All Respect As Per The Direction Of Site Engineer / Engineer-In-Charge Including The Cost Of All Labour, Tools Etc. 334 Plastic Inscription Plate : 335 Supply And Installation Of Approved Quality Plastic Name Inscription Plates Including Engraving The Inscriptions, Providing Screws, Etc. For Equipments Viz. Motors, Motor Control Centres, Switchgears, Push Button Stations Etc. As Required, Providing Necessary Holes Tapping Etc. And Fixing The Same Complete In All Respect As Per The Direction Of Site Engineer / Engineer-In-Charge Including The Cost Of All Labour, Tools Etc. 336 Point Wiring - Supplying, Installation And Testing With 1.5 Sq.Mm Stranded Pvc Insulated Copper Conductor Wires For Phase & Neutral Of 650V Grade Including Earthing By Providing 1.5 Sq.Mm Earth Insulated Continutity Wire Of Copper In Pvc Conduit ( Supply & Installation Of Pvc Conduit Covered Elsewhere In Sor ) Recessed On Wall / Ceiling / False Celing Including Supply & Installation Of Switch Boxes, Junction Boxes, Pull Boxes, Bushes, Screws, Check Nuts, Bends, Modular Switches And Sockets . The Circuit Wiring With 4 Sq.Mm Pvc Copper Wire From D.B. To Switchboard As Required Is Also In The Scope Of The Contractor: 337 1 Light Point Controlled By 1 Switch 338 16 A Power Plug Point Wiring: 339 Wiring For 250 V Single Phase And Neutral 16 Amps Modular Power Plug Point With Pvc Insulated 4 Sq. Mm. Copper Conductor Wires For Phase & Neutral, 650 V Grade Including Earthing, The Third Pin With 2.5 Sq. Mm Copper Conductor Earthing Insulated Continuity Wire, Complete With Providing And Fixing Of 6 Pin 16 / 6A Modular Socket And 20 / 10 A Modular Switch ( 1 Plug Point Per Circuit ) As Per Directions Of Site Engineer. 340 6 A Plug Point Wiring: 341 Wiring For 250 V Single Phase And Neutral 6 Amps Modular Plug Point With Pvc Insulated 2.5 Sq. Mm. Copper Conductor Wires For Phase & Neutral, 650 V Grade Including Earthing, The Third Pin With 1.5 Sq. Mm Copper Conductor Earthing Insulated Continuity Wire, Complete With Providing And Fixing Of 5 Pin 6A Modular Socket And 10 A Modular Switch ( 1 Plug Point Per Circuit ) As Per Directions Of Site Engineer. 342 Ac Point Wiring: 343 Point Wiring For Power Plug Point With 4 Sq.Mm Stranded Pvc Insulated Copper Wire Including Earthing The Third Pin With 2.5 Sq. Mm Copper Insulated Earthing Wire Complete With Supply And Fixing Of Recessed Mounted Industrial Type 3 Pin 32 A Metal Clad Socket And Plug, 20A Mcb ( Motor Duty ) Housed In A 16 Gauge M.S. Box 344 Lighting Distribution Board / Ac Distribution Board - Supply , Installation, Testing And Commissioning Of Tpn Lighting / Ac Distribution Board Of Approved Make, With Rating And Feeders As Per Specification. The Db Shall Be Of Ip-42 Protection Class And Shall Conform To Is 8623. The Board Shall Be Fitted With An Acrylic Door As Per Directions Of Site Engineer: 345 Type Vi Light Db: Euro Db Dboxx Of Havells Or Equivalent Make Complete With Bus Bar, Neutral Links, Earth Links Along With 1 X 6 A Mcb Spn , 7X2 A Spn Mcb, Digital Time Switch , 110 - 240 Vac 1 Phase - 2W, 1 C / O, Base / Din Based Upon Lat / Long Setting Of Location Working According Sunrise And Sunset And Mnx 9-2P Power Contactors 9 A 2 Pole 1 No Or 1 Nc Of L&T Or Equivalent. 346 Critical Light Db: Euro Db Dboxx Of Havells Or Equivalent Make Complete With Bus Bar, Neutral Links, Earth Links And 1 X 6 A Mcb Spn & 7X2 A Spn Mcb 347 Decorative Light Fittings - Supply, Installation, Connection, Earthing And Testing Of The Following Fittings, Including Supply And Installation Of Drop Pipes, Hooks, Fittings, Fixtures, Nuts, Bolts, Supports, On Walls, Outlet Box For Regulators And All Other Required Materials Etc. As Per Directions Of The Site Engineer Including Cost Of All Labour, Tools, Materials Etc. Complete In All Respects.Make Of The Fittings Can Be The Make Mentioned In The Respective Sor Items Or Equivalent Model: 348 Tube Light Fitting Type Quadra 2 Bbs805 2 X Llm 1800 / 840 Psu-E 220V-240V Led Luminaire Of Phillips Or Approved Make, Complete With All Accessories Suitable For Mounting In False Ceiling As Per The Directions By Eic / Site Engineer. 349 Led Ceiling Point: Supply And Fixing Of Surface Mounted Led Ceiling Light Fitting Type Mainstream Spot Aura 15W Of Phillips Or Equivalent Approved Make Complete With All Accessories Such As Led Module, Driver, Optics, Thermal Sink, Connector Blocks Etc Including Installation. 350 Wp Endura Led: Supply And Fixing Of Surface Mounted Weather Proof Endura Led Wt 550 Light Fitting Of Phillips Or Equivalent Approved Make Complete With All Accessories Such As Led Module, Driver, Optics, Thermal Sink, Connector Blocks Etc Including Installation. 351 Supply And Fixing Of Led Wall Light Cat. No. 35022 9W Fitting Of Phillips Or Equivalent Approved Make Complete With All Accessories Such As Led Module, Driver, Optics, Thermal Sink, Connector Blocks Etc Including Installation. 352 Led Light Fittings, Recess Mounting Type, Sereno Led-Rc869b Led 30S-6500 Pse W30l120 D8 Or Equivalent Approved Make With Leds: Supply And Fixing Of Recess Mounted Weather Proof Light Sereno Led-Rc869b Led 30S-6500 Pse W30l120 D8 Or Equiavlent Approved Make With Leds, 42 W Or More, Having 2950 Lumens Or More Output. Led Fitting Of Phillips Or Equivalent Approved Make Complete With All Accessories Such As Led Module, Driver, Optics, Thermal Sink, Connector Blocks Etc Including Installation With Led Of Approved Make. 353 Led Light Fittings With Leds, Sereno Led-Suspended-Sp824 P Led 30S-5000 Gr Od Or Approved Equivalent:Supply And Fixing Of Surface Mounted Weather Proof Light Sp824 P Led 42 W Having 2950 Lumens Output Fitting Of Phillips Or Equivalent Approved Make Complete With All Accessories Such As Led Module, Driver, Optics, Thermal Sink, Connector Blocks Etc Including Installation With Led Of Approved Make. 354 Led Light Fittings, Batten With 2Xtled-Tmc501-2X Tled-36 W P3242 Or Equiavlent Approved Make With Leds: Supply And Fixing Of Wall Mounted / Suspended Type Weather Proof Light 2Xtled-Tmc501-2X Tled Or Equiavlent Approved Make With Leds, 36 W Or More. Led Fitting Of Phillips Or Equivalent Approved Make Complete With All Accessories Such As Led Module, Driver, Optics, Thermal Sink, Connector Blocks Etc Including Installation With Led Of Approved Make. 355 Wt550c Led35scwpsu S1 Pc: Supply And Fixing Of Surface Mounted Weather Proof Light Wt550c Led35scwpsu S1 Pc Led 42 W Having 3500 Lumens Output Fitting Of Phillips Or Equivalent Approved Make Complete With All Accessories Such As Led Module, Driver, Optics, Thermal Sink, Connector Blocks, Etc. Including Installation. 356 Dn170c Led10s-6500 Psu Wh: Supply And Fixing Of Surface Mounted Weather Proof Light Dn170c Led 15 W Having 1000 Lumens Output Fitting Of Phillips Or Equivalent Approved Make Complete With All Accessories Such As Led Module, Driver, Optics, Thermal Sink, Connector Blocks Etc Including Installation. 357 Critical Light: Non Flame Proof Type Pel 240 M / Sl Of Prolite Or Of Approved Make As Per Eic, With 2 X 18 W Led Tl / Lamp Including Sealed Lead Acid Battery Of Suitable Size For Minimum 01 Hour Back Up, Battery Charger, For Fire Fighting Pump Shed, Ht / Lt Room, Battery Room Etc.The Job Includes Connection Of The Fitting, 6A Switch Socket With 2C X 4 Sqmm Cable From Db / Switch Board And As Mentioned Above Including All Accessories Etc. Complete In All Respect As Per Direction Of Eic / Site Engineer. 358 All In One Solar Based Led Street Light: 359 Installation, Testing, Commissioning Charges Of All In One Solar Based Led Street Light Including Supply Of 5 M High Gi Pole ( With Suitable Panel Mounting Arrangement ) And Associated Civil Foundation Works Complete In All Respects. 360 Supplying And Laying Reinforced Cement Concrete Light Duty Hume Pipe, Non Pressure Type ( Np3 ) , Centrifugally Cast Conforming To I.S.458 With 1:3:6 Concrete Casing At Joints As Required With Necessary Slope Including Excavation, Backfilling, Supply Of Collars, Jointing Of Pipes With Stiff Mixture Of Cement Mortar In The Proportion Of 1:2 ( 1 Cement: 2 Fine Sand ) , Testing Of Joints, Complete In All Respects As Per Direction Of The Eic / Site Engineer: 361 300 Mm Dia 362 200 Mm Dia 363 Sand Filling 364 Supplying And Spreading Of Approved Quality Fine Dry River Sand In Cable Trenches Including The Cost Of All Material, Transport, Load And Lift Charges, Labour, Tools And Tackles, Consumables Etc , As Per Directions Of Site Engineer / Engineer-In-Charge 365 Supply Fixing And Erection Of Modular Cable Transit ( Mct ) For Cable Entry To Building In Proper Frame Including Supply Of Peelable Type, Spare Block, Stay Plates Compression Wedgs Etc. With All Accessories Considering 20 % Minimum Spare In Each Module To Be Installed As Per Instruction Of Engineer In Charge / Site Engineer: 366 Galvanised Mild Steel Frame With Packing Space Of Min.120X240 Mm With Multi Diameter Blocks And Accessories With Peeling Off Arrangement To Adjust Cable Size From 3.5Mm To 99Mm Outer Dia 367 Galvanised Mild Steel Frame With Packing Space Of Min.120X180 Mm With Multi Diameter Blocks And Accessories With Peeling Off Arrangement To Adjust Cable Size From 3.5Mm To 99Mm Outer Dia 368 Brick Soling 369 Supply And Laying Of Approved Quality 75 Mm. Thick Second Class Brick Flat Soling With Sand Filling In The Interestices, In Cable Trenches For Protection Of Laid Cables In All Respects Including Consumables, Tools / Equipments And Labour As Per Directions Of Engieer-In-Charge / Site Engineer. 370 Outgoing Mccb Feeder As Per Instructions Of Engineer In Charge 371 Feeder Rating 32A 372 Outgoing Sfu Feeder As Per Instructions Of Engineer In Charge 373 Feeder Rating 32 / 32A 374 Flood Light Luminaires With Separate C.G. Box Including Cost Of Lighting Fixtures: Supply, Installation, Connection And Testing Of Following Flood Light Luminaries Of Philips / Approved Equivalent Make With Suitable Lamps ( Lamps Cost Will Be Paid Separately ) And Seperate Control Gear Box ( Cg Box Cost Will Be Paid Separately ) On Flood Light Mast, Supply And Fixing Of Clamps, Supports, Nuts, Bolts Including Welding, Painting Etc. All Complete With Labour And Materials As Per Directions Of Engineer-In- Charge. 375 Type Qvf 135 / 500 W Halogen Halolite Floodlight Luminaire 376 Type Qvf 135 / 70 W Mhn-Td Halolite Floodlight Luminaire Including Separate Cg Box 377 Control Gear Box For Flood Lighting Including Cost Of C.G. Box: Supply, Installation, Connection, Testing And Commissioning Of Control Gear Box Of Philips / Approved Equivalent Make Suitable For Flood Light Mast Fittings Including Supply Of Steel Structures / Flat / Angles And Welding, Painting Etc. All Complete With Labour And Materials As Per Directions Of The Engineer-In-Charge. 378 Zvx X 300 / 250 / 240, 1X250 W Hpi-T Pressure Die Cast Aluminium Cg Boxrs With Open Construction Ballasts 379 Zvx X 310 / 400 / 240, 1X400 W Hpi-T Pressure Die Cast Aluminium Cg Boxrs With Open Construction Ballasts 380 Zvx 330 / 250 / 240, 1X250 W Son Pressure Die Cast Aluminium Cg Boxes With Open Construction Ballasts 381 Zvx X 410 / 1000 / 220, 1X1000 W Hpi-T Die Cast Aluminium Cg Box 382 Zvx X 260 / 70I / 240, 1 X 70 W Mhn-Td Pressure Die Cast Aluminium Cg Boxes With Open Construction Ballasts 383 Zvx X 340 / 250 / 240, 1X400 W Son Pressure Die Cast Aluminium Cg Boxes With Open Construction Ballasts 384 Supply And Inst. Of C.G. Box For Flame Proof Fittings : Supply, Installation, Connecting, Testing And Commisioning Below Given Flameproof Cg Box, Approved For Zone-1 And Gas Group Iia, Iib Including Supply Of Necessary Mounting Steel Structure / Flat / Angle And Welding, Painting Etc. All Complete With Labour And Materials As Per Directions Of Eic. 385 Type Flpw 927 ( Baliga ) / Type Cgf-1108 ( Crompton ) / 80 W Hpmv Flameproof Cg Box Approved For Zone-I To Gas Group Iia, Iib 386 Supply And Inst. Of Increased Safety Control Gear Box : Supply, Installation, Connecting, Testing And Commisioning Below Given Increase Safety Cg Box, Approved For Division 2 And Gas Group Iia, Iib & Iic Including Supply Of Necessary Mounting Steel Structure / Flat / Angle And Welding, Painting Etc. All Complete With Labour And Materials As Per Directions Of Eic. 387 Type Is 30660 ( Baliga ) / Type Cgi 1108M ( Crompton ) / 80 W Hpmv Increased Safety Cg Box Approved For Division_2 And Gas Group Iia, Iib, Iic 388 Supply Of Lamps : Supply Of Below Given M / S Philips Or Equivalent Make Lamps For Installation In Lighting Fittings / Fixtures As Per Directions Of Eic. 389 Led Bulb 5-6W 390 Led Bulb 9W 391 Led Tubelight 18W 392 Installation Of Lighting Fixtures ( Excluding Cost Of Fixtures ) : Fixing Of Following Light Fittings Attachments On Ms Hanger / Supports / Concrete Wall Structure / Steel Structure Completed With Lead In Wires And Other Accessories All Complete With Labour And Materials As Per Direction Of The Engineer-In-Charge. ( Cost Of Light Fittings / Lamp Control Gears And Other Fittings Shall Be Excluded ) . 393 Flp / Increased Safety Wellglass / Bulkhead / Tubelight / Floodlight 394 Flp / Increased Safety Control Gear Box / Junction Box / Switch / Socket 395 Recessed Tubelight Fitting 396 Ordinary Bulkhead / Pl Type Fitting 397 Street Light Fitting ( Upto 9 M Height ) 398 Street Light Fitting ( More Than 9 M Height ) 399 Floodlight Without Control Gear 400 Control Box For Floodlight 401 Floodlight Without Control Gear ( More Than 9 M Height Including On Fldm ) 402 Control Box For Floodlight ( More Than 9 M Height Including On Fldm ) 403 Overhauling Of Window Ac, Split Ac, Water Cooler Etc. 404 Overhauling And Painting Of Wac, Sac, Wc & Cold Storage Of Different Make & Different Capacities Located At Various Location Within The Iocl Premises. Job Includes Removal Of Machines From Location , Dismantling , Cleaning , Washing , Chemical Cleaning Of Condenser & Cooling Coil , Overhauling , Lubrication Of Blower Motor , Checking , Repair / Rectification / Replacement Of Effective Control Component. Painting Of All Metal Part And Chassis Cover Internal Painting With Primer & Outer Painting With Synthetic Enamel Paint. Cleaning Of Coil & Condenser To Be Done With Wire Brush. Defective / Damage Insulation To Be Replaced. All The Electrical Wires Must Be Dressed Properly. Defective Wires To Be Replaced Including Supply Of Wires. Defective / Damage Asbestos Sheet To Be Replaced. Asbestos Sheet Shall Be Provided By The Owner. Cleaning / Replacement Of Filter By Nylon Filter.Reassembly Of Machine, Shifting To Location & Testing Of Machine. Job Complete In All Respect Including Men & Material And As Per Direction And Instruction Of Site Engineer / Engineer-In-Charge. 405 Monthly Routine Maintenance Of Window Ac, Split Ac, Water Coolers Etc. 406 Routine, Regular And Breakdown Maintenance Of Wac, Sac, Wc And Cold Storage Of Different Make & Different Capacities Installed At Various Location Of Iocl Premises . Job Includes Attending The Complaints Of Machines As Per The Complaint Register And Instruction Of Site Engineer. Job Includes Checking Of Machines, Identification Of Defect, Repair / Replacement Of Defective Component. Rewinding Of Blower Motor. Replacement Of Thermostat, Blower, Fan Blade, Electrical Switches, Control Knob, Wires. Cleaning Of Air Filter, Removal Of Dust From Cooling Coil & Condenser By Removing The Machine From Location If Required. Attending The Minor / Major Leakage Of Refrigerant Gas R-22 / R-12 Arresting The Leak And Recharging The Gas. Repair / Replacement Of Defective Bush / Bearing Of Blower Motor Including Lubrication Of Blower Motor, Tightening Of All The Electrical Connection. Repair / Replacement ( By Repaired Compressor ) Of Defective Compressor. Job Includes Dismantling Of Defective Compressor Either At Site Or At Workshop After Transportation Of Machine To Workshop, Taking Necessary Gate Pass / Permission From Concerned 407 Installation Of Split Ac 408 Transportation, Installation, Testing & Commission Of 2.0 / 3.0 Tr Split Ac Of Any Indian Make. Job Includes Supply And Providing Copper Tube Upto 4.0 Meter, Insulation Of Copper Tube, Refrigerant Gas R-22 Charging, Supply & Fixing Required Electrical Wire. Job Complete In All Respect As Per Direction Of Site Engineer / Engineer-In- Charge. 409 Additional Copper Tube For Split Ac 410 Supply & Fixing Of Additional Length Of Copper Tube For Split A / C Commissioning Including All Accessories. 411 Replacement Of Burnt Uncut Compressor 412 Replacement Of Burnt Uncut Compressor Of 1.5-Ton Capacity From The Manufacturer Whenever Required As Per Direction Of Engineer-In-Charge. 413 Replacement Of Burnt Uncut Compressor Of 1.0 Ton Capacity From The Manufacturer Whenever Required As Per Direction Of Engineer-In-Charge. 414 Gas Charging Of Air Conditioner 415 Gas Charging Of Air Conditioner Upto 1.5 Ton Capacity With Job Involved Transportation Of Machine To Vendors Works. Checking Of All Components For Leak By Charging Co2 Gas & Finally Evacuating The Compressor Completely & Charges Of Refrigerant Gas - 22. A 416 Electrical Service Items 417 Cable Laying - Laying Of All Type Of Cables Lt ( Pvc / Xlpe / Armoured / Unarmoured / Power / Control / Signalling ) In Trenches, In Cable Racks, In Trays, In Protective Pipes, Poles, Columns, In Conduits, In Panels And On Structures Etc.; Including The Supply And Installation Of All Required Materials Such As Fixing Clamps, Screws, Cable Straps, Tags, Etc. As Required ( Other Than The Supply Of The Conduits, Cables, Pipes, Cable Racks, Trays, Poles, Structures And Panels ) Complete In All Respect, Including Cost Of All Labour, Tools, Consumable Materials, Etc. And Cutting The Cables In Required Lengths As Per Directions Of Site Engineer / Engineer-In-Charge: 418 Power Cables Lt : Od Upto 20 Mm 419 Power Cables Lt : Od Above 20 Mm And Upto 40 Mm 420 Power Cables Lt : Od Above 40 Mm And Upto 60 Mm 421 Power Cables Lt : Od Above 60 Mm 422 Power Control Cables Lt : Od Upto 20 Mm 423 Cable Laying - Laying Of All Type Of Cables Lt ( Pvc / Xlpe / Armoured / Unarmoured / Power / Control / Signalling ) In Trenches, In Cable Racks, In Trays, In Protective Pipes, Poles, Columns, In Conduits, In Panels And On Structures Etc.; Including The Supply And Installation Of All Required Materials Such As Fixing Clamps, Screws, Cable Straps, Tags, Etc. As Required ( Other Than The Supply Of The Conduits, Cables, Pipes, Cable Racks, Trays, Poles, Structures And Panels ) Complete In All Respect, Including Cost Of All Labour, Tools, Consumable Materials, Etc. And Cutting The Cables In Required Lengths As Per Directions Of Site Engineer / Engineer-In-Charge: 424 Power Cables Ht 425 Removal Of Rubbish / Debris / Brickbats 426 Removal Of Rubbish / Debris / Brickbats, Laterite Boulders, Earth, Plaster Flakes Etc. Including Carriage By Mechanical Transport Including Packing Stacking The Rubbish In Regular Stacks At Loading Points At Different Places Before Loading The Same In The Trucks And Unloading The Same At Directed Places Upto A Lead Of 2 Km, Including Local Carriage Of Rubbish At Loading And Unloading Point Etc. Complete As Per Direction Of The Engineer-In-Charge. ( Payment Will Be Made By Stack Measurement After Deducting 20% For Voids From Stack Measurement ) . 427 Painting Of Electrical Equipments 428 Cleaning Of Surface, Rust Removing Of Foreign Matter, Rubbing Down Thoroughly With Emery Paper, Wire Brush, Washing With Degreasing Solvent ( White Spirit ) To Remove Grease Etc. And Preparation Of Surface For Application Of Enamel Paint By Spray Painting On Bus Ducts, Transformers / Motors / Or Any Other Metallic Surface With One Coat Of Ready Mixed Primer And Two Coats Of Approved Quality / Apcolite Asian Synthetic Enamel Paint Including Supply Of Paint Suitable For A Temperature Of 100 Degree Celsius. All Complete With Labour And Materials As Per Directions Of The Engineer-Incharge. 429 Cleaning Of Surface, Rust Removing Of Foreign Matter, Rubbing Down Thoroughly With Emery Paper, Wire Brush, Washing With Degreasing Solvent ( White Spirit ) To Remove Grease Etc. And Preparation Of Surface For Application Of Paint By Spray Painting On Electrical Equipment / Structures / Poles Or Any Other Metallic Surface With Two Coats Of Approved Brand & Manufacturer Of Aluminium Paint Including Supply Of Paint Suitable For A Temperature Of 100 Degree Celsius. All Complete With Labour And Materials As Per Directions Of The Engineer-In-Charge. 430 Lettering 431 Lettering With Black Japan Paint Of Approved Brand And Manufacture Note : Unit Of Measurement Is Considered Each Which Is Equal To Per Cm Height Per Letter. 432 Ht Cable Disconnection: Disconnection Of Ht Cables Of Following Sizes At One End And Reconnecting It At Same Place Or Another Place After Dressing And Cleaning The Terminals All Complete With Labour And Materials As Per The Direction Of The The Engineer-Incharge 433 Overall Diameter Upto 35 Mm 434 Overall Diameter > 35 Mm But Upto 55 Mm 435 Overall Diameter >55 Mm But Upto 75 Mm 436 Overall Diameter > 75 Mm 437 Lt Cable Disconnection: Disconnection Of Lt Cables Of Following Sizes At One End And Reconnecting It At Same Place Or Another Place After Dressing And Cleaning The Terminals All Complete With Labour And Materials As Per The Direction Of The The Engineer-In-Charge. 438 Overall Diameter Upto 35 Mm 439 Overall Diameter > 35 Mm But Upto 55 Mm 440 Overall Diameter >55 Mm But Upto 75 Mm 441 Overall Diameter > 75 Mm 442 Temporary Laying And Dismantling Of Cables: Temporary Laying And Dismantling Of Following Cables ( Armoured / Unarmoured, Power / Control / Telecommunication / Computer ) Of Different Voltage Grades / Sizes / Types For Temoprary Connections During Shutdown Etc., Including Transportation Of Cable From Stores / Another Site And Returning The Same After Dismantling To Store, All Complete With Labour And Materials As Per Directions Of The Engineer-Incharge. 443 Overall Diameter Upto 35 Mm 444 Overall Diameter > 35 Mm But Upto 55 Mm 445 Overall Diameter >55 Mm But Upto 75 Mm 446 Overall Diameter > 75 Mm 447 Cleaning Of Light Fitting Fixtures: Cleaning Of Below Given Fitting Fixtures Alongwith Perfex Cover ( Wherever Applicable ) With The Help Of Surf Powder. It Includes The Removal Of Perfex Cover, Washing The Lighting Fixture With Powder, Cleaning With Fresh Water And Clothes And Refixing In The Same Position. It Also Includes Arranging Ladder As And Wherever Required, Providing Scaffolding At All Heights With Necessary Tools & Tackles. All Complete With Labour And Materials As Per Directions Of The Engineer-Incharge. 448 Tube Light Fitting / Ceiling / Exhaust Fan / Fan At Any Height Inside A Building. 449 Mll / Hpmv / Hpsv Lamp Of Flp / Increased Safety / Weather Proof Or Any Other Similar Fittings Upto 250 W 450 Lt Panel Cleaning 451 Cleaning Of Complete Pcc / Mcc Panels. It Includes Opening Of Side Top Covers, Removal Of Dust By Vacuum Cleaners / Blowers Etc., Checking And Tightening Of Screws, Nuts, Bolts, Washers & Connections, Application Of Petroleum Jelly And Boxing Up Of The Panels. All Complete With Labour And Materials As Per Directions Of The Engineer-In-Charge. 452 Earth Resistance Measurement 453 Measurement Of Earthing Resistance In Thepump Station / Rcp / Cp / ( Other Pipeline Installation ) Including Transportation Of Earthing Electrodes, Cables Etc. From Stores To Site, Drawing The Same Into The Ground At Different Points For Measuring The Earth Resistance. The Job Includes The Supply Of Connecting Leads, Clamps Etc. All Complete With Labour And Materials As Per Directions Of The Engineer-In-Charge. Note Measuring Instruments To Be Supplied By The Owner 454 Transformer Cleaning 455 Cleaning Of Transformer Includes Surface Cleaning I.E. Cleaning Of Accumulated Sticky Oil And Other Dust, Oil Fins. Job Includes Opening Of Lt Duct & Ht Terminal Box, Cleaning Of Duct And Terminal Box, Tightening Of Nuts & Bolts Wherever Is Required. Job To Be Completed With All Men, Materials And Equipments Like Tools & Tackles As Per Direction And Satisfaction Of The Engineer-In-Charge. All Cleaning Materials Such As Markin Cloth, Cotton Waste Etc. Shall Be Supplied By The Contractor. 456 Ht / Lt Motor Cleaning: Cleaning Of Ht / Lt Motors & Its Push Button Includes Cleaning Of Accumulated Oil / Spilage Oil & Other Particles On The Surface Of Motor & Connected Cable & Surrounding Area Of The Motor. All Cleaning Material Such As Cotton Waste, Markin Cloth Etc. Shall Be Supplied By The Contractor. Job To Be Completed With All Man & Material As Per Direction & Entire Satisfaction Of The Engineer-In- Charge. 457 Ht Motors 458 Lt Motors Less Than 45 Kw 459 Lt Motors 45 Kw & Above 460 Fixing Of Electrical Components 461 Fixing, Fitting, Commissioning, Assembly Of Loose Supplied Components, If Any, And Connecting Of One No. Switch Fuse Unit / Automate / Starter Of Rating Upto 400 A , 3 Phase, 415 V With On Without Relay In Normal / Explosion Proof Enclosure, Existing / New Distribution Panel Or In Control Panel, Mounted On Wall / Floor Etc. Transportation Of Automate / Starter / Switch Fuse Unit From The Store To The Site ( Maximum Distance Of 10 Km ) . Job Complete In All Respect With Labour And As Per Thedirection Of Engineer-In-Charge Excluding Supply Of Switch Fuse Unit / Automate / Starter. 462 Cable Trench: 463 Excavation In Unpaved Ares Of Earth In The Work Sites For Cables Trenches For A Depth Upto 1.5 Meters Including Shoring, Strutting Etc. ( If Necessary ) , Backfilling The Trench After Cable Laying With Excavated Earth Or Sand Within The Work Sites Complete In All Respects Including Consumables, Tools / Equipments And Labour. The Work Shall Be Performed As Per Directions Of Engineer-In-Charge / Site Engineer. 464 Lightning Arrestor : Erection, Installation, Testing & Commissioning Of Lightning Arrestors With Insulating Base, Discharge Counter, Fittings Etc. Including Assembling As Required, Installation On Already Made Steel Structures Or Fixtures, Aligning, Levelling, Grouting, Assembling And Fitting Of Accessories / Instruments Etc. Supplied Separately, If Any, Making Of The Conductor Connection, Cables Connections As Required, Earthing, Testing, Commissioning The Same, Complete In All Respects Including Consumables, Tools / Equipments And Labour As Per Directions Of Engineer-In-Charge / Site Engineer. The Supply Of Earthing Strip Is Not Covered In This Item. 465 For 60 Kv Rated Voltage ( Highest System Voltage 72.5 Kv ) , 10 Ka Lightening Arrestors 466 For 30 Kv Rated Voltage ( Highest System Voltage 36 Kv ) , 10 Ka Lightening Arrestors 467 Brick Work In Cable Trench: Removal Of Bricks From Cable Trench Without Any Damage To The Cable And Disposing It Within A Lead Of 50 Meteres Or Stacking It At The Edge Of The Trench And Putting It Back Into The Same Trench Or In A New Cable Trench Within A Lead Of 50 Meteres After The Work Is Completed Including Completing The Work In Allrespects With All Labour And Materials As Per The Direction Of The Engineerin-Charge. 468 Removal And Relaying 469 Removal And Stacking Only 470 Removal Of Sand From Cable Trench 471 Removal Of Sand From Cable Trench Without Any Damage To The Cable And Disposing It Within A Lead Of 50 Meteres Or Putting It Back Into The Same Trench Or In A New Cable Trench Within A Lead Of 50 Meteres All Complete With Labour And Materials As Per The Direction Of The Engineer-Incharge. 472 Removal Of Rcc Slab Upto 150 Mm Thick 473 Removal Of Rcc Slab Upto 150 Mm Thick And Of Any Size Placed Above The Cable Trench, Handling Carefully Without Any Damage Of The Slab And Cable Beneath It And Keeping It Back In Position After Laying / Removing The Cable And Sealing The Same Between Rcc Covers With Cement & Sand. Job Complete In All Respect With Labours And Materials And As Per Direction Of Engineer -In-Charge. 474 Cable Dismantling / Pull Out: Dismantling / Pulling Out The Lt / Ht, Pvc / Xlpe, Power / Control / Telephone / Computer, Armoured / Unarmoured Cables Of Various Voltage Grades / Types / Sizes / Makes From The Trench ( Upto 1.5 Metres Deep ) / Pipes / Structures / Racks Or Trays, Rolling It Into Empty Cable Drums, Returning The Filled Up Cable Drums To The Store / Another Site Including Transportation Of Empty Cable Drums From Stores To Site And Filled Up Cable Drums From Site To Stores / Another Site, Etc. Including Cutting Of Cables At Joints / Termination, Dismantling Of Clamps Etc. All Complete With Labour And Materials As Per Directions Of The Engineer-Incharge. 475 Overall Diameter Upto 35 Mm 476 Overall Diameter > 35 Mm But Upto 55 Mm 477 Overall Diameter >55 Mm But Upto 75 Mm 478 Overall Diameter > 75 Mm 479 Cable Dismantling / Pull Out And Relaying: Dismantling / Pulling Out The Lt / Ht, Pvc / Xlpe, Power / Control / Telephone / Computer, Armoured / Unarmoured Cables Of Various Voltage Grades / Types / Sizes / Makes From The Trench ( Upto 1.5 Metres Deep ) / Pipes / Structures / Racks Or Trays And Relaying As Per Direction Of Engineerin-Charge, All Complete With Labour And Materials. Job Includes Declamping, Rerouting And Relaying Of Cable For Reglanding Etc. 480 Overall Diameter Upto 35 Mm 481 Overall Diameter > 35 Mm But Upto 55 Mm 482 Overall Diameter >55 Mm But Upto 75 Mm 483 Overall Diameter > 75 Mm 484 Dismantling Of Power Distribution Equipments: Dismantling Of Following Power Distribution Equipments Without Any Damage To It And Returning It To Our Stores Or Reinstallation Of Same At A Place Within A Lead Of 3 Km ( Reinstallation Charges Not Includes ) All Complete With Labour And Materials As Per The Direction Of The Eic. 485 Small Equipment Requiring Tractor Trailer But Not Requiring Crane / Hydra Etc. ( Beyond 100 Kg. ) 486 Equipment Weighing Above 500 Kg And Requiring Hydra And Tractor Trolley Etc. 487 Equipment Weighing More Than 3 Mt And Requiring Crane And Tractor Trolley Etc 488 Attending Complaints : Attending And Rectification Of Complaint Of The Following Note: All Materials & Accessories Of Fittings Required For Attending The Complaint Shall Be Supplied By The Owner Free Of Cost. The Contractor Has To Take The Material From Central Store / Departmental Store / Site In-Charge. For Attending Above Complaints. The Defective Material Are To Be Returned To The Deptt. Stores. Consumables Items Like Pvc Tape, Cleaning Tape, Cleaning Cloth, Ctc Etc. Are In The Scope Of Contractor. Also Application Of Pvc / M-Seal On Above Fittings To Above Entering Of Water / Insects As Per Direction Of The Engineer-In_Charge. 489 Tube Light Fittings Including Replacement Of Chokes, Tubes, Down Rods, Starters, Starter Holder, Tube Rod And Holders And All Other Accessories If Needed Including Cleaning Of The Light Fittings If Required. All Complete With Labour And Materials As Per Direction Of The Engineer-In-Charge 490 Flp / Increased Safety And Weatherproof Upto 250 W Lamps Including Replacement Of Lamps, Lamp Holders, Connectors, Glass & Other Accessories Etc. Including External And Internal Cleaning Of Glass And Complete Fittings As Well As Other Related Job Involved. All Complete With Labour And Materials As Per Directions Of Engineer- In- Charge. 491 Control Gear Boxes Of Hpmv Lamp Fittings Upto 250W Including Replacement Of Chokes, Condensers, Fuses, Holders, Fuse Base, Wiring Or Any Other Accessories Of Control Gear Box. All Complete With Labour And Materials As Per Directions Of The Engineer-In-Charge. 492 Fldms / Highway Fittings / Street Light Fittings Including Replacement Of Lamps, Tubes, Ignitors, Chokes, Capacitors, Fuses, Fuse Holders, Gasket, Providing / Extension Rod On Lamp Holder Glass Including Cleaning Of Glass Or Any Other Accessories Required. All Complete With Labour And Materials As Per Directions Of The Engineer-In-Charge. 493 Circuit Fault Rectification 494 Rectification Of Circuit Fault In Flp / Non Flp Junction Boxes / Djbs / Dbs / Switchboards Etc. Other Than In Fldms Including Supply Of Minor Type Of Materials Costing Less Than Rs.6.00 In One Complaint. All Complete With Labour And Materials As Per Directions Of The Engineer-In-Charge. Note : Materials Used By Contractor Should Not Exceed Rs.6.00 Per Complaint. Balance Material Exceeding Rs. 6.00 Per Complaint Shall Be Supplied By Owner Free Of Cost. Also Application Of Pvc Putty / M-Seal Putty On Above Fittings, If Required, To Avoid Entering Of Water / Insects As Per Directions Of The Engineer-In Charge. Putty Will Be Supplied By Owner Free Of Cost. 495 Miscellaneous Complaints 496 Attending Complaint Of Installation E.G. Hand Lamps, Flood Lights, Exhaust Fans, Halogen Fittings, Smoking Booth & Other Elect. Complaints & Replacement Of Crocodile Clips On Earthing Leads With A Maximum Period Of One Hour From The Time Of Receipt Of Complaint. 497 Cleaning Of Cable Trenches 498 Cleaning Of Cable Trenches Of Depth Upto 3 Meter And Width 1.5 Meter Of Cable Galleries, Sub Stations And Other Locations Etc. The Job Includes Lifting Of Rcc Slabs / Chequerred Plates, Removing Of Paper Waste Jute, Mud, Or Any Other Unwanted Materials Lying In Trenches & Dumping These Waste Materials In The Nearest Dust Bin Or As Directed By The Engineer-In-Charge., Keeping Back Rcc Slabs / Chequerred Plates In Positions. All Complete With Men And Materials As Per Direction Of The Engineer-In Charge. 499 Horizontal Drilling 500 Making Horizontal Bore / Drill For Roads At Different Location. Job Includes Pipe Coupling & Cutting, Insert The Pipe Through Both Side Of The Road And Make It As Original ( Gi Pipe, Ms Pipe From 2 To 8 Meter Long ) ( Horizontal Drilling ) . Gi / Ms Pipe Supply Shall Be In The Scope Of Iocl. Transportation Of The Pipe From Stores / Site To Work Site Shall Be In The Scope Of The Contractor. 501 Replacement Of Old Transformer Oil 502 Replacement Of The Old Oil From The Transformer As Per The Specifications Given Below A ) Old Oil Heating By Hot Oil Circulator For 4 Hrs. B ) Draining Out Entire Quantity Of Oil. C ) Blanking Of All Opening For Vaccum Pulling. D ) Applying Vacuum Pulling For 4 Hrs Minimum 600 Hg Mercury Pressure. E ) Filtration Of New Transformer Oil For Filling. F ) Filling The Oil Under Vacuum & Filtration Of Oil Till Desired Bdv Is Attained As Per Is. G ) Releasing All The Air From Air Release Plug & Bucholz Relay H ) Topping Up Of Oil. I ) To And Fro Transportation Of Filter Machine And Equipments. J ) Transportation Of Old And New Oil. 503 Wbm Road / Concrete Breaking: 504 Wbm Road / Concrete Breaking For Cable Trenches Including Required Shoring Strutting Etc., And Repairing Of The Road / Dyke To Original Condition And Disposing Off Excess Materials ( Within The Work Site ) Job Complete In All Respects Including The Cost Of Labour, Tools, Materials, Load, Lift Hire Charges Of Equipments, If Any, Complete As Per Directions Of Site Engineer / Engineer-In-Charge. 505 Excavation In Hard Rock : 506 Excavations In Hard Rock Requiring Chiselling For Cable Trenches Upto Depth Of 1.5 Metres, Including Shoring, Strutting ( If Necessary ) , Excavated Earth Or Sand To Be Back Filled ( After Cable Laying ) To The Finished Level And Excess Earth To Be Disposed Off Within The Work Sites Complete In All Respects Including Comsumables, Tools / Equipments And Labour. The Work Shall Be Performed As Per Directions Of Engineer-In-Charge / Site Engineer. 507 Itc Of Ceiling Fan And Regulator With Aluminium Connecting Cable 508 Installation, Testing And Commissioning Of Ceiling Fan And Regulator Including Wiring The Down Rod Of Standard Length ( Upto 30 Cm ) With 1.5 Sqmm, Pvc Insulated, Aluminium Conductor, Single Core Cable Etc. As Required. 509 Installation Of Exhaust Fan:Fixing Of Exhaust Fans On Existing Opening, Complete With Lead In Wires And Other Accessories All Complete With Labour And Materials As Per Direction Of The Engineer-In Charge. ( Cost Of Fans Shall Be Excluded ) 510 With Louver Shutter / Mesh 511 Without Louver Shutter / Mesh 512 Flp / Is Exhaust Fan 513 Dismantling Of Split Ac 514 Dismantling , Shifting Of 2.0 / 3.0 Tr Split Ac Including Dismantling Of All The Copper Tube, Condensing Unit, Electrical Connection To New Location Or A / C Workshop As Per Direction Of Site Engineer / Engineer-In-Charge. 515 Electrical Supply Items 516 Shock Treatment Chart 517 Supply Of Shock Treatment Chart In Glass Frame Suitable For Wall Mounting 518 Safety Equipment - Supplying The Following Safety Equipment As Per Directions Of Site Engineer / Engineer-In-Charge Complete In All Respects Including Transportation Charges: 519 Supply And Installation Of 33 Kv Discharge Rod 520 Supply Of Hand Gloves 521 Suitable For 11 / 33 Kv Voltage Level With Isi Mark And With Test Certificate With Issue Date Within 1 Month 522 Supply Of Elastomer Mat 523 Supply Of 2000Mm X1000 Mm, 3 Mm Thick ( Class B ) Elastomer Mats Conforming To Is: 15652:2006 524 Insulating Elastomer Mats Conforming To Is 15652:2006 Of Thickness 2.5 Mm ( Class B ) 525 Extra For Providing Copper Lugs: Supply ( To Be Used Only When It Is Mentioned In Sor That Lug Supply Is Excluded ) Of Copper Tube Terminal Heavy Duty ( Crimping Cable Lug ) Of Kse / Dowells Make Or Equivalent Certified By Eic. Of The Following Sizes. 526 1.5 Sqm 527 2.5 Sqm 528 4.0 Sqm 529 6.0 Sqm 530 10.0 Sqm 531 16.0 Sqm 532 25 Sqmm 533 Extra For Providing Aluminium Lugs: Supply ( To Be Used Only When It Is Mentioned In Sor That Lug Supply Is Excluded ) Of Aluminium Tube Terminal Heavy Duty ( Crimping Cable Lug ) Of Kse / Dowells Make Or Equivalent Certified By Eic. Of The Following Sizes. 534 16.0 Sqm 535 25 Sqmm 536 35 Sqm 537 50 Sqm 538 70 Sqm 539 120 Sqm 540 150 Sqmm 541 240 Sqmm 542 300 Sqmm 543 Extra For Providing Flameproof Double Compression ( Brass ) Cable Glands: Supply ( To Be Used Only When It Is Mentioned In Sor That Gland Supply Is Excluded ) Of Cmrs / Cce Approved Flameproof Double Compression ( Brass ) Cable Gland For Following Overall Cable Sizes As Per Directions Of Engineer-In-Charge. 544 10.0 To 16.0 Mm 545 16.5 To 18.0 Mm 546 18.5 To 20.0 Mm 547 20.5 To 23.0 Mm 548 23.5 To 26.0 Mm 549 26.5 To 30.0 Mm 550 30.5 To 33.0 Mm 551 33.5 To 37.0 Mm 552 37.5 To 41.0 Mm 553 41.5 To 46.0 Mm 554 46.5 To 52.0 Mm 555 52.5 To 60.0 Mm 556 60.5 To 66.0 Mm 557 Lightning Arrestor : Supply Of Lightning Arrestors With Insulating Base Fittings Etc. As Per Specifications 558 For 60 Kv Rated Voltage ( Highest System Voltage 72.5 Kv ) , 10 Ka Lightening Arrestors 559 For 30 Kv Rated Voltage ( Highest System Voltage 36 Kv ) , 10 Ka Lightening Arrestors 560 Supply Of Materials / Equipments As Given Below Complete In All Respects, As Per The Instruction Of Eic Including Transportation To Site And Storing : 561 Supply Of Zn Grounding Cells ( With Prepackaged Backfill Material ) Including Required Length Of Cable ( Minimum 10 M ) Of Approved Make & As Per Instructions Of Eic. 562 Dcdb 563 Installation And Commissioning Of Wall Mounted Dcdb Including Supply Of All Cable End Lugs, Cable Glands, Fittings & Fixtures And All Other Required Accessories, Tools And Tackles Complete In All Respects As Per Directions Of Site Engineer / Engineer-In-Charge. Item Includes Supply And Termination Of 2 Runs Of 1Cx25 Sq. Mm Copper Cable For Battery Bank 564 Ht 33 Kv, 11 Kv & 6.6 Kv Cables - Screened, Xlpe Insulated, Extruded Pvc Type St-2 Inner Sheathed, Galvaznized Armoured, Pvc Type St-2 Overall Sheathed, Stranded, Frlsh, C2, Smoke Density<40% 565 Al 3Cx120 Mm² 6.6Kv 566 Al 3C X 150 Mm² 6.6 Kv 567 Al 3Cx185 Mm² 6.6Kv 568 Al 3Cx240 Mm² 6.6 Kv 569 Al 3Cx400 Mm² 6.6Kv 570 Al 3Cx400 Mm² 33Kv 571 Lt Cables Frlsh - Aluminium Cables-1.1 Kv, Xlpe Insulated, Extruded Pvc Type St-2 Inner Sheathed, Galvanized Armoured, Pvc Type St-2 Overall Sheathed, Stranded, Frlsh, C2, Smoke Density<40% 572 Al, 3Cx10 Mm², A2xfy 573 Al, 3Cx16 Mm² 574 Al, 4Cx16 Mm², A2xfy 575 Al, 3Cx25 Mm², A2xfy 576 Al, 3.5Cx25 Mm², A2xfy 577 Al, 4Cx25 Mm², A2xfy 578 Al 3C X 35 Mm² 579 Al, 3.5Cx35mm², A2xfy 580 Al, 3Cx50mm² 581 Al, 3.5Cx50 Mm², A2xfy 582 Al, 3½C X 95 Mm² 583 Al, 3½C X 120 Mm² 584 Al, 3.5Cx150 Mm², A2xfy 585 Al, 3C X 185 Mm² 586 Al, 3½C X 185 Mm² 587 Al, 3.5Cx240 Mm², A2xfy 588 Al, 3.5Cx400 Mm², A2xfy 589 Supply Of Xlpe Insulated , Pvc Sheathed Cable, 1100 V Grade Conforming To Is: 7098 ( P-1 ) As Per Specifications And Approved Make 590 Copper Cable Size 1Cx50 Sq. Mm Armoured 591 Copper Cable Size 1Cx35 Sq. Mm Armoured 592 Copper Cable Size 1Cx25 Sq.Mm Armoured 593 Copper Cable Size 2Cx6 Sq.Mm Armoured 594 Copper Cable Size 2Cx25 Sq.Mm Armoured 595 Copper Cable Size 2Cx70 Sq.Mm Armoured 596 Tinned Copper Cable Size 1Cx10 Sq.Mm Unarmoured For Distributed Anodes Of Station Cp System 597 Civil Items 598 Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level : 1:2:4 [ 1 Cement : 2 Coarse Sand Derived From Natural Sources : 4 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ] 599 Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level :Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More 600 Brick Work With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 In Foundation And Plinth In : Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) 601 Random Rubble Masonry With Hard Stone In Superstructure Above Plinth Level And Upto Floor Five Level, Including Leveling Up With Cement Concrete 1:6:12 ( 1 Cement : 6 Coarse Sand : 12 Graded Stone Aggregate 20 Mm Nominal Size ) At Window Sills, Ceiling Level And The Like. 602 12Mm Plaster ( In Coarse Sand ) :1:4 ( 1 Cement : 4 Coarse Sand ) 603 Casting, Supplying And Erecting In Position Precast Reinforced Cement Concrete Elements ( With Proper Lifting Lugs ) For Trench & Drain Covers, Shelves, Partitions, Post, Slabs Etc. For All Leads And Levels Including Making Necessary Moulds, Vibrating, Tamping, Curing, Finishing The Top Surface With Cement Mortar 1:3 ( 1 Cement : 3 Fine Sand ) To Give A Smooth And Even Surface, Transportation To Site, Aligning And Fixing In Position With Cement Mortar 1:3 ( 1 Cement: 3 Find Sand, ) Including Making Recess In Brick Wall For Placing The Precast Element In Position And Making Good The Same Etc. Complete In All Respects Inclusive Of Cost Of All Labour, Materials, Tools, Tackles Etc. As Per Directions Of The Engineer-In-Charge. [ Note: Payment For Reinforcement Shall Be Made As Per Relevant Item Of Sor. ] :With Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 10 Mm Nominal Size ) . 604 Motor Items 605 Rewinding Of Lt Motor Upto & Incl 11 Kw As Per Special Conditions Of Contract ( Technical ) Of Tender Document 606 Rewinding Of Lt Motor 12-18 Kw As Per Special Conditions Of Contract ( Technical ) Of Tender Document 607 Rewinding Of Lt Motor 132-150 Kw As Per Special Conditions Of Contract ( Technical ) Of Tender Document 608 Overhauling Of Lt Motor Upto & Incl 11 Kw As Per Special Conditions Of Contract ( Technical ) Of Tender Document 609 Overhauling Of Lt Motor 12-15 Kw As Per Special Conditions Of Contract ( Technical ) Of Tender Document 610 Overhauling Of Lt Motor 132-260 Kw As Per Special Conditions Of Contract ( Technical ) Of Tender Document 611 Shaft Metallizing / Repair Of Lt Motor Upto & Incl 11 Kw As Per Special Conditions Of Contract ( Technical ) Of Tender Document 612 Shaft Metallizing / Repair Of Lt Motor 12-15 Kw As Per Special Conditions Of Contract ( Technical ) Of Tender Document 613 Shaft Metallizing / Repair Of Lt Motor 16-21 Kw As Per Special Conditions Of Contract ( Technical ) Of Tender Document 614 Shaft Metallizing / Repair Of Lt Motor 111-150 Kw As Per Special Conditions Of Contract ( Technical ) Of Tender Document 615 Dynamic Balancing Of Lt Motor Upto & Incl 11 Kw As Per Special Conditions Of Contract ( Technical ) Of Tender Document 616 Dynamic Balancing Of Lt Motor 12-15 Kw As Per Special Conditions Of Contract ( Technical ) Of Tender Document 617 Dynamic Balancing Of Lt Motor 111-150 Kw As Per Special Conditions Of Contract ( Technical ) Of Tender Document 618 Supply Terminal Plate Of Lt Motor Upto & Incl 11 Kw As Per Special Conditions Of Contract ( Technical ) Of Tender Document 619 Supply Terminal Plate Of Lt Motor 12-18 Kw As Per Special Conditions Of Contract ( Technical ) Of Tender Document 620 Supply Terminal Plate Of Lt Motor 111-150 Kw As Per Special Conditions Of Contract ( Technical ) Of Tender Document 621 Supply Of Cooling Fan Lt Motor Upto & Incl 11 Kw As Per Special Conditions Of Contract ( Technical ) Of Tender Document 622 Supply Of Cooling Fan Lt Motor 12-18 Kw As Per Special Conditions Of Contract ( Technical ) Of Tender Document 623 Supply Of Cooling Fan Lt Motor 111-150 Kw As Per Special Conditions Of Contract ( Technical ) Of Tender Document 624 Supply Of Fan Cover Lt Motor Upto & Incl 11 Kw As Per Special Conditions Of Contract ( Technical ) Of Tender Document 625 Supply Of Fan Cover Lt Motor 12-18 Kw As Per Special Conditions Of Contract ( Technical ) Of Tender Document 626 Supply Of Fan Cover Lt Motor 111-150 Kw As Per Special Conditions Of Contract ( Technical ) Of Tender Document 627 Supply Of End Shield Lt Motor Upto & Incl 11 Kw As Per Special Conditions Of Contract ( Technical ) Of Tender Document 628 Supply Of End Shield Lt Motor 12-15 Kw As Per Special Conditions Of Contract ( Technical ) Of Tender Document 629 Supply Of End Shield Lt Motor 111-150 Kw As Per Special Conditions Of Contract ( Technical ) Of Tender Document 630 Suply Of Bearing Cover Lt Motor Upto & Incl 11 Kw As Per Special Conditions Of Contract ( Technical ) Of Tender Document 631 Suply Of Bearing Cover Lt Motor 12-18 Kw As Per Special Conditions Of Contract ( Technical ) Of Tender Document 632 Suply Of Bearing Cover Lt Motor 111-150 Kw As Per Special Conditions Of Contract ( Technical ) Of Tender Document 633 Erection, Testing And Commissioning Of Motor On Existing Foundation Including Carriage From Stores To The Site, Unpacking, Placing On Foundation, Levelling, Fixing And Fitting Of All Components, Making Necessary Connections, Phase Checking, Meggering As Necessary All Complete With Labour And Materials As Per The Direction Of Engineer-In-Charge.- Small Equipment Requiring Tractor Trailer But Not Requiring Crane / Hydra Etc. ( Beyond 100 Kg. ) 634 Erection, Testing And Commissioning Of Motor On Existing Foundation Including Carriage From Stores To The Site, Unpacking, Placing On Foundation, Levelling, Fixing And Fitting Of All Components, Making Necessary Connections, Phase Checking, Meggering As Necessary All Complete With Labour And Materials As Per The Direction Of Engineer-In-Charge.- Equipment, Panels, Motor Etc. Weighing Above 500 Kg And Requiring Hydra And Tractor Trolley Etc.But <3Mt 635 Erection, Testing And Commissioning Of Motor On Existing Foundation Including Carriage From Stores To The Site, Unpacking, Placing On Foundation, Levelling, Fixing And Fitting Of All Components, Making Necessary Connections, Phase Checking, Meggering As Necessary All Complete With Labour And Materials As Per The Direction Of Engineer-In-Charge.- Equipment, Panels, Motor Etc.Weighing More Than 3 Mt And Requiring Crane And Tractor Trolley But <25Mt 636 Supply And Installation Of L&T / Siemenas Or Equilent Make Dol Motor Starter ( With All Acessaries Including O / L Relay Etc. ) Confirming To Is:13947-4 On Walls / Steel Structure, Connection Of Cables All Complete With Labour And Materials As Per Direction Of The Engineer- In-Charge- Upto 5.5Kw 637 Supply And Installation Of L&T / Siemenas Or Equilent Make Dol Motor Starter ( With All Acessaries Including O / L Relay Etc. ) Confirming To Is:13947-4 On Walls / Steel Structure, Connection Of Cables All Complete With Labour And Materials As Per Direction Of The Engineer- In-Charge- 5.5 To 7.5 Kw 638 Supply And Installation Of L&T / Siemenas Or Equilent Make Dol Motor Starter ( With All Acessaries Including O / L Relay Etc. ) Confirming To Is:13947-4 On Walls / Steel Structure, Connection Of Cables All Complete With Labour And Materials As Per Direction Of The Engineer- In-Charge-7.5 To 11Kw 639 Supply And Installation Of L&T / Siemenas Or Equilent Make Dol Motor Starter ( With All Acessaries Including O / L Relay Etc. ) Confirming To Is:13947-4 On Walls / Steel Structure, Connection Of Cables All Complete With Labour And Materials As Per Direction Of The Engineer- In-Charge- 11 To 15Kw 640 Transportation Of Lt Induction Motor For Rewinding Frompump Station To ContractorS Works And Back To Pump Station. This Includes Arranging Suitable Vehicle For To & Fro Transportation, Unloading & Loading The Motor At Rewinding Works. All Complete With Labour, Materials, Tools And Tackles As Per The Direction Of Engineer-In-Charge.Note: Lifting Facility To Put The Motor In The Vehicle At Our End Will Be Provided By Iocl For The Motors Of Capacity More Than 15 Kw.- Motor Upto 1.5 Kw 641 Transportation Of Lt Induction Motor For Rewinding Frompump Station To ContractorS Works And Back To Pump Station. This Includes Arranging Suitable Vehicle For To & Fro Transportation, Unloading & Loading The Motor At Rewinding Works. All Complete With Labour, Materials, Tools And Tackles As Per The Direction Of Engineer-In-Charge.Note: Lifting Facility To Put The Motor In The Vehicle At Our End Will Be Provided By Iocl For The Motors Of Capacity More Than 15 Kw.- Motor Above 1.5 Kw To 18.5 Kw 642 Transportation Of Lt Induction Motor For Rewinding Frompump Station To ContractorS Works And Back To Pump Station. This Includes Arranging Suitable Vehicle For To & Fro Transportation, Unloading & Loading The Motor At Rewinding Works. All Complete With Labour, Materials, Tools And Tackles As Per The Direction Of Engineer-In-Charge.Note: Lifting Facility To Put The Motor In The Vehicle At Our End Will Be Provided By Iocl For The Motors Of Capacity More Than 15 Kw.- Motor Above 75 Kw To 160 Kw 643 Online Condition Monitoring And Diagnostic Testing Of 6.6 Kv Ht Motors As Per Tender Specifications 644 Offline Condition Monitoring And Diagnostic Testing Of 6.6 Kv Ht Motors As Per Tender Specifications 645 Offline Diagnostic Testing Of Ht Cables As Per Tender Specifications 646 Fixed Charges For Transportation Of Equipments, Mobilisation Of Engineers & Instruments, Accomodation Arrangement By Contractor Itself During Work At Site, Lodging And Boarding Etc. For Carrying Out Work At Erpl Patna Pump Station.
Contract Date : 12 Apr, 2023   |   Contract Value : 28.83 Lakhs
BRR : 9544088 Tender For Composite Works For Ambient Air Heating System Project At Kll Dabhol; 1 PIPING-OFFSITES 2 PIPING (ABOVE GROUND) :-Transportation of all piping items from Owners storage point to work site/work shop; fabrication including cutting, edge preparation, (inclusive of grinding the edges of pipe, pipe spools, fittings, flanges etc. to match with the mating edges of uneven/different thickness wherever required); fitup, bending, preheating wherever required, welding, threading, and laying of pipes and pipe spools (spools along with supports) of all types and thickness over sleepers, overhead on racks and at all elevations, hook-ups with existing piping, connecting with equipment nozzles, strainers, steam traps, static mixers, sight flow indicators, thermal sleeve, orifice assemblies, spray nozzles, rotameters, tappings for pressure gauges, thermowells, sample connections, sample coolers, closed sample system cabinets etc. and fixing of gaskets, bolts, nuts including application of torque wherever requiredandall other inline instruments and fittings, like elbows, reducers, tees, flanges, spectacle blinds and spacer and blinds, piping specials such as mitres and fabricated fittings, vents, drains (but excluding reinforcingpads), SW valves upto 1.5 NB, Steam Supply/ Condensate Recovery stations(Cast/Fabricated), Supplyandwelding of Strip as per EIL Std 7-51-0112 to all pipes before hydro-testing at exit points of Units for earthing purpose; alignment, cleaningandflushing by water/compressed air,hydrostatic, pneumatic, vacuum, spark testing and any other type of testing as specified draining, drying by compressed air, performing Positive Material Identification(PMI) using alloy analysers, completing all such works in all respects (including preparation of isometrics as mentioned in the Scope of Work for the job) as per the specifications, drawings and instructions of Engineer-in-Charge. PMI shall be performed by third party as defined in PMI spec.Rates for tubing (if any) shall include rates for valves, fittings, all in line instruments and testing etc. Carbon steel piping includes LTCS piping also. Erectionof all inline instruments like flow instrumentsandspecialty items like static mixers, sample coolers, thermal sleeve, air mixers, exhaust head, rupture disk, flow meters, venturi tube, flame arrestor, thermal flow switch etc. except valve shall be considered as part of piping and separate payment shall not be made on this account. Note : Contractor to refer to Instrumentation SOR for specific details and rates of Instrumentation items not covered herein. 3 CARBON STEEL PIPING (NON IBR); THK. <= 10MM 4 FABRICATION (BUTT WELD- MANUAL) 5 NB UPTO 1.5 INCH 6 NB 2 INCH - 6 INCH 7 NB 8 INCH - 14 INCH 8 NB 16 INCH - 24 INCH 9 NB 26 INCH - 36 INCH 10 FABRICATION (FILLET WELD) 11 NB UPTO 1.5 INCH 12 ERECTION (OTHER THAN SPOOL) 13 NB UPTO 1.5 INCH 14 NB 2 INCH - 6 INCH 15 NB 8 INCH - 14 INCH 16 NB 16 INCH - 24 INCH 17 NB 26 INCH - 36 INCH 18 CARBON STEEL PIPING (NON IBR); THK. > 10MM AND <= 20MM 19 FABRICATION (BUTT WELD- MANUAL) 20 NB 8 INCH - 14 INCH 21 NB 16 INCH - 24 INCH 22 NB 38 INCH - 48 INCH 23 ERECTION (OTHER THAN SPOOL) 24 NB 8 INCH - 14 INCH 25 NB 16 INCH - 24 INCH 26 NB 38 INCH - 48 INCH 27 STAINLESS STEEL PIPING (NON-IBR); THK. <= 10MM 28 FABRICATION (BUTT WELD- MANUAL) 29 NB UPTO 1.5 INCH 30 NB 2 INCH - 6 INCH 31 FABRICATION (FILLET WELD) 32 NB UPTO 1.5 INCH 33 ERECTION (OTHER THAN SPOOL) 34 NB UPTO 1.5 INCH 35 NB 2 INCH - 6 INCH 36 VALVES :- Transportation of all types of valves (Including special valves and motor operatedvalves) from Owners storage points to contractors stores/worksite and installation of valvesfor all rating including assembly of valves accessories like air bottles etc, if any, fixing of gaskets bolts/nuts wherever required and performing Positive Material Identification(PMI) using alloy analysers as per specification, drawings and directions of Engineer-in-Charge. Note : For PRDS, PSVs, TSVs, Control valves, On-Off/Shutdown valvesandSelf actuating valves all details and rates shall be as per Instrumentation SOR. 37 FLANGED/WAFER VALVES INCLUDING MOV (UPTO 600#) 38 NB2.000 INCHES 39 NB3.000 INCHES 40 NB4.000 INCHES 41 NB6.000 INCHES 42 NB8.000 INCHES 43 NB 10.000 INCHES 44 NB 12.000 INCHES 45 NB 20.000 INCHES 46 NB 24.000 INCHES 47 NB 42.000 INCHES 48 SPRING SUPPORT ASSEMBLIES :- Transportation of all types of spring support assemblies from Owners storage points to contractors stores/worksite and installation of spring support assemblies for all rating including assembly, if any, fixing of gaskets bolts/nuts, welding attachments wherever required and performing Positive Material Identification(PMI) using alloy analysers as per specification, drawings and directions of Engineer-in-Charge. Contractor to ensure that travel stops are removed and spring is locked in cold load position for Hydrotest. It shall be ensured that locking devices are removed and springs are properly set at hot load position during commissioning. 49 SOR Sl. No.: 49 || PART NO: 0 || SOR NO: B861-000-16-43-PK-SOR-3001-0-0M ||ITEM NO: M21901000000 50 BOLT TENSIONING :- Carrying out tensioning of bolted joints on all types of piping as called for in EIL Specification No.6-76-0002 on already erected system including supply of all materials, recording devices, instruments etc; Providing all normal and special equipment and gadgets, skilled / un skilled labour, specialist, supervisory staff and completing the work in all respects as per specifications and instructions of engineer-in-charge. some joints may require bolt tensioning more than once, but, payment for one joint shall be made only once. 51 150# JOINTS 52 NB 12.000 INCHES 53 NB 16.000 INCHES 54 NB 18.000 INCHES 55 NB 20.000 INCHES 56 NB 24.000 INCHES 57 NB 42.000 INCHES 58 300# JOINTS 59 NB 12.000 INCHES 60 NB 24.000 INCHES 61 REINFORCING PADS FOR PIPES :- Fabrication ofreinforcingpads for pipeconnection wherever required (from pipes only suppliedbytheOwner) and erection, fitup, weldingandtesting (including DP/MP) if required of the same and performing Positive Material Identification(PMI) using alloy analysers as per the specifications, drawings and instructions ofthe Engineer-in-Charge. Note: Sizes mentioned forReinforcing Pads are for branch pipe 62 C.S REINFORCING PADS 63 NB2.000 INCHES 64 NB3.000 INCHES 65 NB6.000INCHES 66 NB8.000 INCHES 67 NB 10.000INCHES 68 NB 12.000 INCHES 69 NB 18.000INCHES 70 NB 24.000 INCHES 71 NB 28.000 INCHES 72 RADIOGRAPHY :- Performance of radiographic inspection on piping of all typesandthicknesses including providing or hiring of all necessary equipment and whatever else even though not expressly mentioned but required to perform the work as per specificationsand instructions of Engineer-in-Charge. Radiographs shall be submitted to the Engineer-in-charge. (Repeat Radiography due to defective radiograph on repaired joints due to Contractors fault and for additional radiography necessitated due to poor performance of contractors welders shall be done at contractors cost) Note: Unit for radiography quantity is Nos of circumferencial weld joints. 73 FOR JOINTS THK. <= 8MM (FOR CS OTHER THAN CLASS lV OF JOB NDE SPECIFICATION) 74 NB0.750 INCHES 75 NB1.000 INCHES 76 NB1.500 INCHES 77 NB2.000 INCHES 78 NB3.000 INCHES 79 NB4.000 INCHES 80 NB6.000 INCHES 81 FOR JOINTS THK. <= 8MM (FOR CS AS PER CLASS lV OF JOB NDE SPECIFICATION/AS/SS) 82 NB2.000 INCHES 83 FOR JOINTS ABOVE THK. 8MM 84 NB8.000 INCHES 85 NB 12.000 INCHES 86 NB 18.000 INCHES 87 NB 24.000 INCHES 88 NB 42.000 INCHES 89 DYE PENETRATION/MAGNETIC PARTICLE TEST :- Performance of magnetic particle/ dye penetrant test including supply of all necessary materials, equipment and labour for carrying out the work as per specification and directions of Engineer-in-Charge. 90 DYE PENETRANT TEST 91 MAGNETIC PARTICLE TEST 92 PIPE SUPPORTS (FROM MATERIALS SUPPLIED BY OWNER) :- Fabrication, erection(at all elevations) of pipe supports like shoes, cradles,hangers, clamps(of all sizes/thicknesses manufactured by forming method using die), turn buckles, saddles, guides,special supports, pads(including corrosion pads & protection shields), providing and welding of stiffeners as per drawings, T post etc. of all types including supply and application one coat of primer, all necessary equipments, consumables, labour,returning surplus materials and scrap etc to owners storage points and completing work as per drawings, specifications and instructions of Engineer-in-charge. Modifications/rectifications, if required; andadjustment/ alignment during precommisioning, commisioning as per the instructions ofEngineer-in-charge. Fabrication of extension of spindle for valves, provision of locking arrangement, etc. shall also be considered under this item. 93 DUMMY PIPE SUPPORTS FOR C.S (OWNER SUPPLIED) 94 DUMMY PIPE SUPPORTS FOR S.S (OWNER SUPPLIED) 95 PIPE SUPPORTS (FROM MATERIALS SUPPLIED BY CONTRACTOR) :- Fabrication, erection(at all elevations) of pipe supports like shoes, cradles,hangers, clamps(of all sizes/thicknesses manufactured by forming method using die), turn buckles, saddles, guides,special supports, pads(including corrosion pads & protection shields), providing and welding of stiffeners as per drawings, T post etc. of all types including supply and application one coat of primer, all necessary equipments, consumables, labour, and completing work as per drawings, specifications and instructions of Engineer-in-charge. Modifications/rectifications, if required; andadjustment/ alignment during precommisioning, commisioning as per the instructions ofEngineer-in-charge. Fabrication of extension of spindle for valves, provision of locking arrangement, etc. shall also be considered under this item. 96 C.S STRUCTURAL STEEL (CONTRACTOR SUPPLIED) 97 S.S STRUCTURAL STEEL (CONTRACTOR SUPPLIED) 98 DUMMY PIPE SUPPORTS FOR C.S (CONTRACTOR SUPPLIED) 99 DUMMY PIPE SUPPORTS FOR S.S (CONTRACTOR SUPPLIED) 100 WOODEN/HIGH DENSITY PUF SUPPORTS FOR COLD LINES :- Supply, shaping, positioning and fixing of cold line supports as per EIL pipe support standard having the following specifications: Wood specification:Hard wood, chemically treated with creosote under pressure. Quality of wood to conform class-I durability as per IS-3629 & Grade-I timber of Group-A withpermissible compression strength of 70 Kg/cm2 perpendicular to grains as per IS-883. PUF specifications: Density for lines upto 6 NB : 240 kg/cm3 Density for lines above 6 NB : 320 kg/cm3 101 WOODEN BLOCKS 102 HIGH DENSITY (240 Kg/Cu.M) PUF BLOCKS 103 HIGH DENSITY (320 Kg/Cu.M) PUF BLOCKS 104 CHEMICAL CLEANING/PICKLING :- Cleaning and pickling of equipment/pipeline includng preparation of circulation loop, supply of temporary piping, pumps, heater coils, gaskets, thermometer, hydrometer, valve, test coupon, spares, laboratoryfacilities, with all accessories for conducting test, chemicals, safety accessories and also providing or hiring all necessary equipment and whatever else even though not expressly mentionedhereinandinspecificaions but required to perform the work as per specifications and instructions ofEngineer-in-Charge. 105 PASSIVATION OF COOLING WATER LINES 106 NB0.500 INCHES 107 NB0.750 INCHES 108 NB1.000 INCHES 109 NB1.500 INCHES 110 NB2.000 INCHES 111 NB3.000 INCHES 112 NB4.000 INCHES 113 NB6.000 INCHES 114 NB8.000 INCHES 115 NB 10.000 INCHES 116 NB 12.000 INCHES 117 NB 14.000 INCHES 118 NB 16.000 INCHES 119 NB 18.000 INCHES 120 NB 20.000 INCHES 121 NB 24.000 INCHES 122 NB 42.000 INCHES 123 FABRICATION & ERECTION OF BLINDS/SPECTACLE BLINDS/SPACER & BLINDS ETC. :- Transportation from owners storage point to work site, fabrication and erection of blinds, spectacle blinds, spacers & blinds of all ratings from plate material of all thicknesses supplied by owner as free issue; cutting, edge preparation, rolling, fit up, welding, cleaning, testing (hydrotesting, MP/DP, radiography), wherever required bolts nuts & gaskets including supply of necessary equipment, consumables, labour etc as per standards / specifications and directions of Engineer-in-charge 124 BLINDS 125 NB0.750 INCHES 126 NB1.000 INCHES 127 NB1.500 INCHES 128 NB2.000 INCHES 129 NB3.000 INCHES 130 NB4.000 INCHES 131 NB6.000 INCHES 132 NB8.000 INCHES 133 NB 12.000 INCHES 134 NB 24.000 INCHES 135 NB 42.000 INCHES 136 SPECTACLE BLINDS 137 NB2.000 INCHES 138 NB3.000 INCHES 139 SPACERS & BLINDS 140 NB 24.000 INCHES 141 NB 42.000 INCHES 142 SUPPLY OF STUDS ALONG WITH NUTS: Supply as per Technical Notes for Fasteners (6-44-0057) from Vendor enlisted in Project Master Supplier List of Studs along with two nutsfor diameter < 1 and 3 nuts for diamemter >= 1of nuts, as per the direction of Engineer in-charge. All Alloy steel fasteners used in SS Piping shall be Hot Dip Galvanized. 143 AS FASTENERS(ASTM A193 GR.B7/B7M/A194 GR.2H/2HM) 144 MODIFICATION/EXTRA WORKS (IF ANY) :- Cutting, bevelling, fitup, welding of different sizes of CS/AS/SS/Higher Alloy piping of all types and thicknessess in shop, in position, on ground/overhead on rack and at all elevations; transportation of pipes, fittings, flanges etc from owners storage point to work site/ work shop, making necessary scaffoldings, consumables, machinery, tools, tackles, labour and supervision including attending repairs for completing the work as per the instruction of Engineer-in-charge. 145 FLAME CUTTING C.S PIPINGIBR/NON IBR 146 HACKSAW CUTTING C.S PIPINGIBR/NON IBR 147 BEVELLINGC.S PIPINGIBR/NON IBR 148 FITUP & WELDINGC.S PIPINGIBR/NON IBR 149 FLAME CUTTINGS.S PIPINGIBR/NON IBR 150 HACKSAW CUTTINGS.S PIPINGIBR/NON IBR 151 BEVELLINGS.S PIPINGIBR/NON IBR 152 FITUP & WELDINGS.S PIPINGIBR/NON IBR 153 REMOVAL ERECTED PIPING(ABOVE GROUND) :- Removal of piping existing/ erected including SW valves for modification as required as per Drawings/P and IDs/instructions of Engineer-in-charge at all elevations, including providing assistance to owner for draining, cleaning and purging of the lines to be removed , unbolting of flanged joints /cutting of pipe lines wherever required, installation of flanges and blind flanges, removal of insulation from insulated lines, removing supports, steam tracers, all fittings and flanges, instruments etc, cutting of pipes in appropriate length for transporting purposes, cleaning, flushing, drying and transporting all materials to storage point(within the complex battery limits) designated by Owner/EIL including stacking of material and disposing of waste etc as instructed by Engineer-in-charge. 154 C.S/A.S PIPING 155 S.S PIPING 156 REMOVAL OF ERECTED VALVES (ABOVE GROUND) :- Removal of all types and ratings of valves by unbolting, cutting etc. as required, cleaning by flushing with water/air etc. asrequiredand transportation of the same to Owners storage point (within thecomplex battery limits) and stacking as per instructions of Engineer-in-Charge. 157 VALVES OTHER THAN CONTROL VALVES 158 NB0.500 INCHES 159 NB0.750 INCHES 160 NB1.000 INCHES 161 NB1.500 INCHES 162 NB2.000 INCHES 163 NB3.000 INCHES 164 NB4.000 INCHES 165 NB6.000 INCHES 166 NB8.000 INCHES 167 NB 10.000 INCHES 168 NB 12.000 INCHES 169 NB 24.000 INCHES 170 NB 42.000 INCHES 171 LOW FRICTION PADS: Supply, fabrication and fixing of low friction pads with suitable bonding materials / fasteners, as specified in Drawings / Isometrics / Special support sketches. 172 TEFLON PAD WITH COMPRESSIVE STRENGTH (0.25 OFFSET) :1870 PSI 173 GRAPHITE PAD WITH COMPRESSIVE STRENGTH : 2877 PSI 174 PRE-COMMISSIONING / COMMISSIONING ASSISTANCE : Carrying out Pre-commissioning / Commissioning activities such as dropping the valves, control valves and spool pieces, air and water flushing and air-blasting, steam blowing, air drying, re-installing the valves, control valves and spool pieces, leak testing etc. as per pre-commissioning / commissioning specification/ procedure and instruction of Engineer-in-charge including supply of necessary hand tools, equipments/ machinery, consumables (electrodes, filler wire, gas, card board, target plate, scaffolding etc. wherever required) and with single point responsibility of Contractors supervision.Note : This manpower will be utilized forPre-commissioning & Commissioning requirement over and above that already described elsewhere in this SOR.One Man day is 12 hour duty. 175 SKILLED (WITH HAND TOOLS, EQUIPMENT/MACHINERY, CONSUMABLES) 176 SEMI SKILLED (WITH HAND TOOLS) 177 HELPER/ UNSKILLED 178 PIPE DAVITS :Supply, fabrication & erection of pipe davits as per EIL std. 7-12-023 for lowering of aircooler motors/safety valves from structural platforms, fixing the same to platforms, inspection as per specs., supply of all necessary materials, equipment, consumables, labour,supervision etc. The work shall be carried out as per the specifications, drawings & instruction of engineerincharge. 179 SOR Sl. No.: 179 || PART NO: 0 || SOR NO: B861-000-16-43-PK-SOR-3001-0-0M ||ITEM NO: M25201000000 180 SUPPLY OF BULK PIPING ITEMS :- Procurement andsupply of following bulk piping items to site/ownersstorage, transportation to work site/fabrication shop.Procurement shall be done as per EIL specifications andfrom Client/EIL approved suppliers.Contractor shall establish quantities from drawingsconsidering wastage, cutting allowance, escalation &spares required by Client 181 PIPES 182 PIPE, B-36.10, ASTM A 106 GR.B, PE, SEAMLESS, 0.5 INCH, S160 183 PIPE, B-36.10, ASTM A 106 GR.B, PE, SEAMLESS, 0.75 INCH, S160 184 PIPE, B-36.10, ASTM A 106 GR.B, PE, SEAMLESS, 1.0 INCH, XS 185 PIPE, B-36.10, ASTM A 106 GR.B, PE, SEAMLESS, 1.5 INCH, XS 186 PIPE, B-36.19, ASTM A 312 TP304, PE, SEAMLESS, 0.5 INCH, 80S 187 PIPE, B-36.19, ASTM A 312 TP304, PE, SEAMLESS, 0.75 INCH, 80S 188 PIPE, B-36.19, ASTM A 312 TP304L, PE, SEAMLESS, 0.75 INCH, 80S 189 FLANGES 190 FLNG.SW, B-16.5, ASTM A 105, 300, RF/125AARH, 1.0 INCH, XS 191 FLNG.SW, B-16.5, ASTM A 105, 300, RF/125AARH, 1.5 INCH, XS 192 FLNG.WN, B-16.5, ASTM A 105, 150, RF/125AARH, 0.75 INCH, S160 193 FLNG.WN, B-16.5, ASTM A 105, 150, RF/125AARH, 1.0 INCH, XS 194 FLNG.WN, B-16.5, ASTM A 105, 150, RF/125AARH, 1.5 INCH, XS 195 FLNG.WN, B-16.5, ASTM A 182 GR.F304, 150, RF/125AARH, 0.75 INCH, 80S 196 FLNG.BLIND, B-16.5, ASTM A 105, 150, RF/125AARH, 0.75 INCH 197 FLNG.BLIND, B-16.5, ASTM A 105, 150, RF/125AARH, 1.0 INCH 198 FLNG.BLIND, B-16.5, ASTM A 105, 150, RF/125AARH, 1.5 INCH 199 FLNG.BLIND, B-16.5, ASTM A 105, 300, RF/125AARH, 1.0 INCH 200 FLNG.BLIND, B-16.5, ASTM A 182 GR.F304, 150, RF/125AARH, 0.75 INCH 201 FITTINGS 202 ELBOW.90, B-16.11, ASTM A 105, SW, 3000, 1.0 INCH 203 ELBOW.90, B-16.11, ASTM A 105, SW, 3000, 1.5 INCH 204 ELBOW.90, B-16.11, ASTM A 105, SW, 6000, 0.75 INCH 205 ELBOW.90, B-16.11, ASTM A 182 GR.F304L, SW, 3000, 0.75 INCH 206 T.EQUAL, B-16.11, ASTM A 105, SW, 3000, 1.5 INCH 207 T.EQUAL, B-16.11, ASTM A 182 GR.F304L, SW, 3000, 0.75 INCH 208 T.RED, B-16.11, ASTM A 105, SW, 3000, 1.5 INCH, 0.75 INCH 209 SWAGE.CONC, BS-3799, ASTM A 105, PBE, 0.75 INCH, S160, 0.5 INCH, S160 210 CPLNG.FULL, B-16.11, ASTM A 105, SW, 3000, 1.0 INCH 211 CPLNG.FULL, B-16.11, ASTM A 182 GR.F304L, SW, 3000, 0.75 INCH 212 CPLNG.HALF, B-16.11, ASTM A 105, SW, 3000, 1.0 INCH 213 CPLNG.HALF, B-16.11, ASTM A 105, SW, 3000, 1.5 INCH 214 CPLNG.HALF, B-16.11, ASTM A 105, SW, 6000, 0.75 INCH 215 CPLNG.HALF, B-16.11, ASTM A 182 GR.F304, SW, 3000, 0.75 INCH 216 CPLNG.LH, B-16.11, ASTM A 105, SW, 3000, 1.5 INCH 217 VALVES 218 VLV.GATE, SHEET 51001, 0.5 INCH 219 VLV.GATE, SHEET 51001, 0.75 INCH 220 VLV.GATE, SHEET 51001, 1.0 INCH, LOCK OPEN 221 VLV.GATE, SHEET 51001, 1.0 INCH 222 VLV.GATE, SHEET 51001, 1.5 INCH, LOCK OPEN 223 VLV.GATE, SHEET 51001, 1.5 INCH 224 VLV.GATE, SHEET 51007, 0.75 INCH 225 VLV.GATE, SHEET 51045, 0.5 INCH 226 VLV.GATE, SHEET 51045, 0.75 INCH 227 VLV.GLOBE, SHEET 52001, 1.0 INCH 228 VLV.GLOBE, SHEET 52007, 1.0 INCH 229 VLV.CHECK, SHEET 53001, 1.0 INCH 230 VLV.CHECK, SHEET 53007, 1.0 INCH 231 VLV.CHECK, SHEET 53050, 0.75 INCH 232 GASKETS 233 GASKET, B-16.20-ANSI B16.5, SP.WND SS316+GRAFIL+ I RING, SPIRAL, 150, 0.75 INCH 234 GASKET, B-16.20-ANSI B16.5, SP.WND SS316+GRAFIL+ I RING, SPIRAL, 150, 1.0 INCH 235 GASKET, B-16.20-ANSI B16.5, SP.WND SS316+GRAFIL+ I RING, SPIRAL, 150, 1.5 INCH 236 GASKET, B-16.20-ANSI B16.5, SP.WND SS316+GRAFIL+ I RING, SPIRAL, 300, 1.0 INCH 237 GASKET, B-16.20-ANSI B16.5, SP.WND SS316+GRAFIL+ I RING, SPIRAL, 300, 1.5 INCH 238 FASTENERS 239 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.5 INCH X 2.5 INCH 240 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.5 INCH X 2.75 INCH 241 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.625 INCH X 3.0 INCH 242 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.625 INCH X 3.25 INCH 243 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.625 INCH X 3.5 INCH 244 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.625 INCH X 3.75 INCH 245 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.625 INCH X 4.0 INCH 246 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.75 INCH X 3.5 INCH 247 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.75 INCH X 4.0 INCH 248 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.75 INCH X 4.25 INCH 249 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7(HDG), A194 GR.2H(HDG), 0.5 INCH X 2.5 INCH 250 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7(HDG), A194 GR.2H(HDG), 0.625 INCH X 3.25 INCH 251 CLOSE PROXIMITY RADIOGRAPHY:-Performance of radiographic inspection on piping of all types & thicknesses includingproviding or hiring of all necessary equipment and whatever else even though notexpressly mentioned but required to perform the work as per specification andinstructions of Engineer-in-Charge by using SELENIUM& IRIDIUM source basedradiography system. Radiography shall be submitted tothe Engineer-in-charge.(Repeat Radiography due todefective radiograph on reparired joints due toContractors fault and for additional radiographynecessitated due to poor performance of contractorswelders shall be done at contractors cost).Note: Unit for radiography quantity is Nos ofcircumferencial weld joints, and rates are also inclusive of scaffoldings wherverrequired. 252 FOR JOINTS THK. <= 8MM (FOR CS OTHER THAN CLASS lV OF JOB NDE SPECIFICATION) 253 NB0.750 INCHES 254 NB1.000 INCHES 255 NB1.500 INCHES 256 NB2.000 INCHES 257 NB3.000 INCHES 258 NB4.000 INCHES 259 NB6.000 INCHES 260 FOR JOINTS THK. <= 8MM (FOR CS AS PER CLASS lV OF JOB NDE SPECIFICATION/AS/SS) 261 NB2.000 INCHES 262 FOR JOINTS ABOVE THK. 8MM 263 NB8.000 INCHES 264 NB 12.000 INCHES 265 NB 18.000 INCHES 266 NB 24.000 INCHES 267 Supply,fabrication and fixing of low friction pad (SS 304 mirror finish) with suitablebonding material/ fasteners as specified in drawing/documents/special supportsketches/isometrics/Gads etc. 268 STAINLESS STEEL 6 MM THK WITH MIRROR FINISH SS304 269 External Chemical Cleaning and Passivation of SSWelds:External chemical cleaning and pickling of SS welds as per latest approved pipingdrawings and as per Job Specification B861-000-06-42-CCS-011. Work shall includesupply of all chemicals, temporary facilities with all accessories for conducting test,safety accessories and also providing or hiring all necessary equipment and whateverelse even though not expressly mentioned herein and in specifications but required toperform the work as per specifications and instructions of Engineer-in-Charge.(Unit ofmeasurement- No. of Joints) 270 NB0.500 INCHES 271 NB0.750 INCHES 272 NB1.000 INCHES 273 NB1.500 INCHES 274 NB2.000 INCHES 275 PAINTING (OFFSITES) :- Supply of paints and primers, preparation of surfaces and application of primer and finish paints, identification (Line numbering), lettering, colour bands, colour coding etc. as specified including rubdown and touch up of shop primer wherever required, providing scaffolding for all heights, labour, material, tools and tackles, consumables supervision etc. to complete the work in all respects as per EIL painting spec., drawings and direction of Engineer-in-Charge for all types of uninsulated piping and insulated piping as specified including all pipes, fittings, flanges, supports, valves etc. Surface preparation by blast cleaning and application of first coat of primer (inorganic zinc silicate, F9) shall be done in fabrication yard prior to erection. For insulated piping wherever blast cleaning with no primer application is specified, in such cases finish paints shall also be applied inthe fabrication yard.The identification marks of the piping and joints shall be noted before blasting and the same shall be transferred on primed surface with Polyurethane paint (F2) or as per the instructions of Engineer-in-Charge. Notes: 1. All joints (fabricationas well as erection joints) shall be left unpainted till hydrotesting. 2. No extra payment shall be made for identification (line numbering etc.) of insulated and uninsulated lines. 276 SURFACE PREP, PRIMER & FINISH COAT FOR CS, AS & LTCS BARE SURFACES FORENVIRONMENT AS PER JOB SPEC B861-000-06-42-PLS-01 277 DESIGN TEMP GROUP: -16 TO 80(DEG C)SURFACE PREPARATION:SSPC-SP-10;1coat of F-9 @ 65-75µ DFT/coat, PRIMER: 1 coat of P-6 @ 40µ DFT/coat, FINISH COAT: 2 coats of F-6B @ 100µ DFT/coat + 1 coat of F-2 @ 40µ DFT/coat (2x100 + 40= 240). Total DFT = 345-355. 278 PIPES 279 NB: .5Inches 280 NB: .75 Inches 281 NB: 1 Inches 282 NB: 1.5 Inches 283 NB: 2 Inches 284 NB: 3 Inches 285 NB: 4 Inches 286 NB: 6 Inches 287 NB: 8 Inches 288 NB: 12Inches 289 VALVES 290 NB: .5Inches 291 NB: .75 Inches 292 NB: 1 Inches 293 NB: 1.5 Inches 294 NB: 2 Inches 295 NB: 3 Inches 296 NB: 4 Inches 297 NB: 6 Inches 298 NB: 8 Inches 299 NB: 12Inches 300 SURFACE PREP, PRIMER &FINISH COAT FOR CS & LTCS INSULATED SURFACES FOR ALLENVIRONMENT AS PER JOB SPEC B861-000-06-42-PLS-01 301 DESIGN TEMP GROUP: -45 TO 125(DEG C)SURFACE PREPARATION: SSPC-SP-10;1 coat of F-15 @ 75µ DFT/coat, PRIMER: None, FINISH COAT: 2 coats of F-15 @ 75µ DFT/coat. Total DFT = 225 302 PIPES 303 NB: .5Inches 304 NB: .75 Inches 305 NB: 1 Inches 306 NB: 1.5 Inches 307 NB: 2 Inches 308 NB: 3 Inches 309 NB: 4 Inches 310 NB: 6 Inches 311 NB: 8 Inches 312 NB: 12Inches 313 NB: 18Inches 314 NB: 24Inches 315 NB: 28Inches 316 NB: 36Inches 317 NB: 42Inches 318 VALVES 319 NB: .5Inches 320 NB: .75 Inches 321 NB: 1 Inches 322 NB: 1.5 Inches 323 NB: 2 Inches 324 NB: 3 Inches 325 NB: 4 Inches 326 NB: 6 Inches 327 NB: 8 Inches 328 NB: 12Inches 329 NB: 18Inches 330 NB: 24Inches 331 NB: 42Inches 332 SURFACE PREP, PRIMER & FINISH COAT FOR CS, AS & LTCS BARE SURFACES FOR ENVIRONMENT AS PER JOB SPEC B861-000-06-42-PLS-01 333 DESIGN TEMP GROUP: -45 TO -15(DEG C)SURFACE PREPARATION:SSPC-SP-10; 1 coat of F-9 @ 65-75µ DFT/ coat. Total DFT = 65-75. 334 PIPES 335 NB0.50 INCHES 336 NB0.750 INCHES 337 NB1.000 INCHES 338 NB1.500 INCHES 339 NB2.000 INCHES 340 NB3.000 INCHES 341 NB4.000 INCHES 342 NB6.000 INCHES 343 NB12.000 INCHES 344 VALVES 345 NB0.50 INCHES 346 NB0.750 INCHES 347 NB1.000 INCHES 348 NB1.500 INCHES 349 NB2.000 INCHES 350 NB3.000 INCHES 351 NB4.000 INCHES 352 NB6.000 INCHES 353 NB12.000 INCHES 354 *************************************************************** LEGENDS / NOTES FOR INSULATION WORKS***************************************************************** Types of Insulation :CC =Cold Conservation Insulation SC =Surface Condensation InsulationH = Heat Conservation InsulationCPP =Cold Personal protectionHPP = Hot Personnel Protection Insulation** Basic Line Surface Materials:CS = Carbon Steel (Including LT Carbon Steel)AS = Alloy SteelSS = Stainless Steel ** Notes : 1. For Insulation specification, refer Job specification for Insulation of Piping and Equipment, B861-000-06-43-IL-S001*************************************************************** 355 COLD INSULATION (OFFSITES) Providing thermal insulation including supply of all insulating andancillary materials, Aluminium foil for SS surfaces, vapour barrier, weather protective coverings, consumables and other necessary materials , testing of materials as required , including transportation of materials to work site, duly inspected by 3rd party inspector(Llyods/BV/DNV or any other Client approved party) at manufacturers shop & sample check/inspection at site by EIL Construction inspector,applying insulation on surfaces as specified including all preparatory works there on, binding, tying, lacing, stitching and/or otherwise securing , finishing with cladding as per spec., providing bolts, rivets, and self tapping screws wherever specified , providing inspection windows, end seals for flanges etc., colour coding and identification. Providing steel scaffolding, all tools , tackles , equipments etc. , labour, supervision and completing the work in all respect, at all heights as per drawings , specifications and instructions ofEngineer-in-charge. (Refer Legend for applicable EIL specification) 356 INSULATION MATERIAL : PREFORMED POLYISOCYANURATE RIGID FOAM(PIR) 357 INSULATION TYPE : CC; SURFACE MATERIAL : CS & AS; OPERATING TEMP. RANGE : UPTO -45 (DEG C); INSULATION MATERIAL : PREFORMED POLYISOCYANURATE RIGID FOAM(PIR) 358 PIPES 359 NB 00.75 INCHES; THICKNESS25 MM 360 NB 01.00INCHES; THICKNESS25 MM 361 NB 01.50 INCHES; THICKNESS50 MM 362 NB 02.00 INCHES; THICKNESS50 MM 363 NB 06.00INCHES; THICKNESS50 MM 364 NB 08.00INCHES; THICKNESS50 MM 365 NB 012.000INCHES; THICKNESS60 MM 366 NB 018.000INCHES; THICKNESS60 MM 367 NB 24.00 INCHES; THICKNESS60 MM 368 NB 28.00 INCHES; THICKNESS60 MM 369 NB 42.00 INCHES; THICKNESS60 MM 370 FLANGE ASSEMBLIES 371 NB 00.75INCHES; THICKNESS25 MM 372 NB 01.00INCHES; THICKNESS25 MM 373 NB 01.50 INCHES; THICKNESS50 MM 374 NB 02.00INCHES; THICKNESS50 MM 375 NB 06.00INCHES; THICKNESS50 MM 376 NB 08.00INCHES; THICKNESS50 MM 377 NB 012.000INCHES; THICKNESS60 MM 378 NB 018.000INCHES; THICKNESS60 MM 379 NB 24.00 INCHES; THICKNESS60 MM 380 NB 42.00 INCHES; THICKNESS60 MM 381 BLIND FLANGE ASSEMBLIES 382 NB 00.75 INCHES; THICKNESS25 MM 383 NB 08.00 INCHES; THICKNESS50 MM 384 VALVE ASSEMBLIES 385 NB 00.75 INCHES; THICKNESS25 MM 386 NB 01.00INCHES; THICKNESS25 MM 387 NB 01.50INCHES; THICKNESS50 MM 388 NB 02.00 INCHES; THICKNESS50 MM 389 NB 06.00INCHES; THICKNESS50 MM 390 NB 08.00 INCHES; THICKNESS50 MM 391 NB 012.000INCHES; THICKNESS60 MM 392 NB 018.000INCHES; THICKNESS60 MM 393 NB 24.00 INCHES; THICKNESS60 MM 394 NB 42.00 INCHES; THICKNESS60 MM 395 INSULATION TYPE : SC; SURFACE MATERIAL : CS & AS; OPERATING TEMP. RANGE : UPTO -45 (DEG C); INSULATION MATERIAL : PREFORMED POLYISOCYANURATE RIGID FOAM(PIR) 396 PIPES 397 NB 00.50 INCHES; THICKNESS25 MM 398 NB 00.75 INCHES; THICKNESS25 MM 399 NB 01.00 INCHES; THICKNESS25 MM 400 NB 01.50 INCHES; THICKNESS25 MM 401 NB 02.00 INCHES; THICKNESS25 MM 402 NB 03.00 INCHES; THICKNESS25 MM 403 NB 04.00 INCHES; THICKNESS40 MM 404 NB 06.00 INCHES; THICKNESS25 MM 405 NB 06.00 INCHES; THICKNESS40 MM 406 NB 08.00 INCHES; THICKNESS25 MM 407 NB 08.00 INCHES; THICKNESS40 MM 408 NB 12.00 INCHES; THICKNESS40 MM 409 NB 18.00 INCHES; THICKNESS40 MM 410 NB 24.00 INCHES; THICKNESS40 MM 411 NB 24.00 INCHES; THICKNESS50 MM 412 NB 28.00 INCHES; THICKNESS50 MM 413 NB 42.00 INCHES; THICKNESS50 MM 414 FLANGE ASSEMBLIES 415 NB 00.50INCHES; THICKNESS25 MM 416 NB 00.75INCHES; THICKNESS25 MM 417 NB 01.00INCHES; THICKNESS25 MM 418 NB 01.50 INCHES; THICKNESS25 MM 419 NB 02.00 INCHES; THICKNESS25 MM 420 NB 03.00INCHES; THICKNESS25 MM 421 NB 04.00INCHES; THICKNESS40 MM 422 NB 06.00 INCHES; THICKNESS25 MM 423 NB 06.00 INCHES; THICKNESS40 MM 424 NB 08.00INCHES; THICKNESS25 MM 425 NB 08.00INCHES; THICKNESS40 MM 426 NB 12.00 INCHES; THICKNESS40 MM 427 NB 018.000INCHES; THICKNESS40 MM 428 NB 24.00 INCHES; THICKNESS40 MM 429 NB 24.00 INCHES; THICKNESS50 MM 430 NB 42.00 INCHES; THICKNESS50 MM 431 BLIND FLANGE ASSEMBLIES 432 NB 00.75 INCHES; THICKNESS25 MM 433 NB 01.00 INCHES; THICKNESS25 MM 434 NB 01.50 INCHES; THICKNESS25 MM 435 NB 02.00 INCHES; THICKNESS25 MM 436 NB 08.00 INCHES; THICKNESS40 MM 437 NB 24.00 INCHES; THICKNESS50 MM 438 VALVE ASSEMBLIES 439 NB 00.50 INCHES; THICKNESS25 MM 440 NB 00.75 INCHES; THICKNESS25 MM 441 NB 01.00 INCHES; THICKNESS25 MM 442 NB 01.50 INCHES; THICKNESS25 MM 443 NB 02.00 INCHES; THICKNESS25 MM 444 NB 03.00 INCHES; THICKNESS25 MM 445 NB 04.00 INCHES; THICKNESS40 MM 446 NB 06.00INCHES; THICKNESS25 MM 447 NB 06.00INCHES; THICKNESS40 MM 448 NB 08.00 INCHES; THICKNESS25 MM 449 NB 08.00 INCHES; THICKNESS40 MM 450 NB 12.00 INCHES; THICKNESS40 MM 451 NB 018.000INCHES; THICKNESS40 MM 452 NB 24.00 INCHES; THICKNESS40 MM 453 NB 24.00 INCHES; THICKNESS50 MM 454 NB 42.00 INCHES; THICKNESS50 MM 455 ELECTRICAL WORKS 456 Design, detailed engineering, preparation of documents, manufacture, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturers works, preparation of graphics for the total microprocessor based analogue addressable type fire detection & alarm system including supply of required software, packing, delivery of the following, including supply of all commissioning spares & special tools and tackles, erection material & documentation as per the enclosed EIL standard specifications, scope of work/job specification, data sheets etc. and other codes and standards attached or referred. 457 8-loop microprocessor based DGFAP with HMI with battery &charger (refer block diagram) 458 Microprocessor based Repeater panel with battery and charger (refer block diagram) 459 Multi - sensor type addressable detectors with junction boxes for safe area 460 Intrinsically safeHeat Detector-addressable type 461 Addressable Linear Beam detectors with transmitter, receiver, reflector for safe area. 462 Zener barrier 463 Outdoor weather proof addressable Break Glass Unit (BGU)/Manual call point (IP-65)in safe area. 464 Indoor addressable Break Glass Unit (BGU) in safe area. 465 Addressable type electronic hooter with minimum 6W output 466 Wall mounting type one faced exit signs suitable for indoor location 467 Ceiling mounting type double faced exit signs suitable for indoor location 468 Weather proof (IP-65) Fault Isolating Modules for loops connecting outdoor break glass units 469 Fault Isolating Modules for loops connecting indoor break glass units/detectors/hooters etc. 470 Control modules with integral junction box installed within loop 471 Input Module with integral junction box installed within loop 472 Industrial type 5 km diametrical range siren with Siren control & starter panel 473 Response indicator for rooms and concealed area for Addressable Fire alarm system 474 Hooter acknowledge Box 475 Providing training for TWO Nos. OWNERs Engineers for a period of 4 days at manufacturer works for Fire Alarm system 476 Providing training for FIVE Nos. OWNERs Engineers at site for the complete fire alarm system 477 Mandatory spares for Fire Alarm system as perCl.6.1 (Mandatory spares), sr.no.15 of EDB document no. B861-000-16-50-EDB-1001 478 Supply, inspection at shop, delivery at site of safe area weatherproof/ indoor push button type desktop/ wallmounting type Analogue caller ID telephone handsets (corded landline phones) with numeric key pad and redialling facility complete with all accessories including all labour and materail. as per approved drawings, specifications of this tender and directions of Engineer-in-ChargeExisting exchange distribution boxes make is ADC Krone, UK 479 Supply, inspection at shop, delivery at site of safe area weatherproof/ indoor push button type desktop/ wall mounting type Analogue non caller ID telephone handsets complete with all accessories including all labour and materail. as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.Existing exchange distribution boxes make is ADC Krone, UK 480 Installation, testing and commissioning of safe area weatherproof/ indoor push button type desktop/ wall mounting type telephone handsets complete with all accessories including all labour and materail. as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 481 Design, detailed engineering, manufacture, preparation of documents, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturers works, packing, supply & delivery of plant communication system supply of all commissioning spares and special tools & tackles, erection & installation material & documentation as per the enclosed EIL specifications, Job specifications/scope of work, datasheets etc and other codes & standards attached or referred. 482 Desktop type Master Call Station (Central Control Unit withMain Master Control Controller with Gooseneck MIC and All Call & Inter-MCD Call facility) with 24 keys suitable for connection with existing 16 Way Microprocessor based Central Control Exchange of DD Electronic Equipment’s PVT Ltd make.Make & model no. of Desktop type Master call station shall be same/ similar make as that of existing.Existing make is DD Electronic Equipment’s PVT Ltd with Model No: LDD8950/20 483 480W BOOSTER AMPLIFIER UNIT including all accessories such as zonal relay cards, IOs, interconnection cables etc. suitable for integration with existing exchange of make DD equipments. Make & Model no. of Booster amplifier unit shall be same/similar make as that of existing.Existing make is BOSCH with Model No: LBD 1938 484 Weather proof IP-65 loud speaker 15/20 Watt suitable for integration with existing exchange of make DD equipments. Make & Model no. of Booster amplifier unit shall be same/similar make as that of existing. Existing make & model no. is Make – DNH ; Model - HS15T 485 Supply, installation and connection of CU earth plates ( 380x45x10) size, complete with anchor bolts, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in- Charge. 486 Unit Rates for UPS ACDB feeders/components 487 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU upto 32 A with Isolation Transformer 488 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU 63 A with Isolation Transformer 489 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU 100 A with Isolation Transformer 490 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU upto 32 A without Isolation Transformer 491 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU 63 A without Isolation Transformer 492 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU 100 A without Isolation Transformer 493 supply& connection of 300A, 230V ACDB Vertical Empty Panel along with bus bar 494 Supply, mounting & wiring of Fully equipped outgoing feeder (230V SFU 16 A with 230/240V step up transformer) 495 Supply, mounting & wiring of Fully equipped outgoing feeder (230V SFU 32 A with 230/240V step up transformer) 496 Supply, mounting & wiring of Fully equipped outgoing feeder (230V SFU 63 A with 230/240V step up transformer) 497 Supply, mounting & wiring of 100A switch 498 Supply, mounting & wiring of 63A switch 499 Supply, mounting & wiring of 32A switch 500 Supply, mounting & wiring of 100A semiconducting fuse 501 Supply, mounting & wiring of 63A semiconducting fuse 502 Supply, mounting & wiring of 32A semiconducting fuse 503 Supply, mounting & wiring of 100A HRC fuse 504 Supply, mounting & wiring of 63A HRC fuse 505 Supply, mounting & wiring of 32A HRC fuse 506 Supply, mounting & wiring of 6 kVA 230V/230V Isolating Transformer 507 Supply, mounting & wiring of 5 kVA 230V/230V Isolating Transformer 508 Supply, mounting & wiring of 4 kVA 230V/230V Isolating Transformer 509 Supply, mounting & wiring of 3 kVA 230V/230V Isolating Transformer 510 Supply, mounting & wiring of 2 kVA 230V/230V Isolating Transformer 511 Supply, mounting & wiring of 1 kVA 230V/230V Isolating Transformer 512 Unit rates for 110V DCDB feeders/components 513 supply& connection of 350A, 110V DCDB Vertical Empty Panel along with bus bar 514 Supply, mounting & wiring of 63A, 110V DC SFU fully equipped outgoing feeder 515 Supply, mounting & wiring of 32A, 110V DC SFU fully equipped outgoing feeder 516 Supply, mounting & wiring of 16A, 110V DC SFU fully equipped outgoing feeder 517 Supply, mounting & wiring of 32A, 110V DC SFC (switch fuse+ contactor) fully equipped outgoing feeder 518 Supply, mounting & wiring of 16A, 110V DC SFC (switch fuse+ contactor) fully equipped outgoing feeder 519 Supply, mounting & wiring of 100A, 110V DC Switch 520 Supply, mounting & wiring of 63A, 110V DC Switch 521 Supply, mounting & wiring of 32A, 110V DC Switch 522 Supply, mounting & wiring of 16A, 110V DC Switch 523 Supply, mounting & wiring of 100A, 110V DC fuse Link 524 Supply, mounting & wiring of 63A, 110V DC fuse Link 525 Supply, mounting & wiring of 32A, 110V DC fuse Link 526 Supply, mounting & wiring of 16A, 110V DC fuse Link 527 Supply, mounting & wiring of 100A, 110V DC contactor 528 Supply, mounting & wiring of 63A, 110V DC contactor 529 Supply, mounting & wiring of 32A, 110V DC contactor 530 Supply, mounting & wiring of 16A, 110V DC contactor 531 TRANSFORMERS 532 Installation of transformers of the following ratings excluding the construction of foundation, includingtransportation from store/yard to site at the place of installation, unpacking, positioning in place, site assembly of loosely furnished accessories, including connection of auxiliary circuits, topping up with oil and testing of oil with contractors own test equipment, including fixing of nuts and bolts etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 533 2 Winding ONAN outdoor transformer with off circuit tap changer. 11 kV/ .433 kV2.5 MV·A 534 2 Winding ONAN outdoor transformer with off circuit tap changer. 11 kV/ .433 kV1.6 MV·A 535 2 Winding ONAN/ONAF outdoor transformer with OLTC. 11 kV/ 6.9 kV6.3 MV·A 536 Filtration of transformer oil by stream line filter machine provided by the contractor for improving the insulation strength of oil to the required strength,including all labour and materials,specifications of this tender and directions of Engineer-in-Charge.(Excluding the supply of oil). 537 Filtration of transformer oil with dissolved gas analysis test. 538 Filtration of transformer oil without dissolved gas analysis test. 539 Supply of transformer oil conforming to IS-335 in non-returnable 220 litre drums for topping up various transformers. The oil shall be tested prior to filling up and improved by filtering, if required, including all labour and materials,specifications of this tender and directions of Engineer-in-Charge. 540 No. of Drums. 541 Supply of dry type transformers with accessories,including nuts and bolts etc., as per EIL standard specification No. 6-51-0042, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 542 2 Winding Dry type transformers. .415 kV/ .415 kV75 kV·A 543 2 Winding Dry type transformers. .415 kV/ .415 kV160 kV·A 544 Installation, testing and commissioning of dry transformer of following rating, including transportation from store/yard to site at the place of installation, unpacking, positioning in place, site assembly of loosely furnished accessories, connection of auxiliary circuits,including fixing of nuts and bolts etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 545 2 Winding Dry type transformers. .415 kV/ .415 kV75 kV·A 546 2 Winding Dry type transformers. .415 kV/ .415 kV160 kV·A 547 Testing and commissioning of transformers of the following rating including all labour and materials, as per specifications of this tender and directions of Engineer-in-Charge. 548 2 Winding ONAN outdoor transformer with off circuit tap changer. 11 kV/ .433 kV2.5 MV·A 549 2 Winding ONAN outdoor transformer with off circuit tap changer. 11 kV/ .433 kV1.6 MV·A 550 2 Winding ONAN/ONAF outdoor transformer with OLTC. 11 kV/ 6.9 kV6.3 MV·A 551 SWITCHBOARDS / UPS / VSD / BATTERY CHARGERS / PANELS 552 Installation, testing and commissioning of switch-boards, relay and control panels, annunciation panels, UPS system, battery chargers, distribution boards, cubicles with electrical equipment, VSD panels, misc. electrical panels etc., including transportation from store/yard to site at the place of installation, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor, interconnection of shipping sections and requisite inter-panel wiring between shipping sections, including supply of all wiring materials, installation on foundations or fixing to wall or steel structures, aligning, levelling, grouting, testing and calibration of relays and meters etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 553 Weight of the Unit upto 100 kg. 554 Weight of the Unit from 101 upto 500 kg. 555 Installation of switch-boards, relay and control panels, annunciation panels, UPS system, battery chargers, distribution boards, cubicles with electrical equipment, VSD panels, misc. electrical panels etc., including transportation from store/yard to site at the place of installation, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor etc., interconnection of shipping sections and requisite inter-panel wiring between shipping sections, including supply of all wiring materials, installation on foundations or fixing to wall or steel structures, aligning, levelling, grouting, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineers-in-Charge. 556 Weight of the Unit upto 100 kg. 557 Weight of the Unit from 101 upto 500 kg. 558 Installation, testing and commissioning of bus ducts of following ratings between transformer secondary and the switchgear incomer panel, including transportation from store/yard to site at the place of installation, unpacking, making connections and installation of bends, breaking of walls and making good of the same etc., (but excluding structural supports), including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 559 Air Insulated/segregated bus ducts 415 V4000 A65 kAfor 1 second 560 Air Insulated/segregated bus ducts 415 V2500 A65 kAfor 1 second 561 Installation, testing and commissioning of switch-boards, relay and control panels, annunciation panels, UPS system, battery chargers, distribution boards, cubicles with electrical equipment, VSD panels, misc .electrical panels etc., including transportation from store/yard to site at the place of installation, lifting the panels by deployment of tyre mounted hydraulic trollies, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor, interconnection of shipping sections and requisite inter-panel wiring between shipping sections, including supply of all wiring materials, installation on foundations or fixing to wall or steel structures, aligning, levelling, grouting, testing and calibration of relays and meters etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 562 Weight of the Unit upto 100 kg 563 Weight of the Unit from 101 upto 500 kg. 564 Weight of the Unit from 501 upto 1000 kg. 565 Weight of the Unit from 1001 upto 1500 kg. 566 Weight of the Unit from 1501 upto 3000 kg. 567 Installation of switch-boards, relay and control panels, annunciation panels, UPS system, battery chargers, distribution boards, cubicles with electrical equipment, VSD panels, misc .electrical panels etc., including transportation from store/yard to site at the place of installation, lifting the panels by deployment of tyre mounted hydraulic trollies, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor, interconnection of shipping sections and requisite inter-panel wiring between shipping sections, including supply of all wiring materials, installation on foundations or fixing to wall or steel structures, aligning, levelling, grouting, testing and calibration of relays and meters etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 568 Weight of the Unit upto 100 kg 569 Weight of the Unit from 101 upto 500 kg. 570 Weight of the Unit from 501 upto 1000 kg. 571 Weight of the Unit from 1001 upto 1500 kg. 572 Weight of the Unit from 1501 upto 3000 kg. 573 Design, engineering, manufacture, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturers works, packing, delivery to site including all labour and materials along with supply of special tools & tackles for following Single Phase, 50 Hz UPS System along with associated accessories and AC Distribution Board complete with documentations as per approved drawings, specifications, data sheets and other codes & standards attached or referred with this tender and directions of Engineer-in-charge. 574 55KVA, 230V, 50 Hz, SPNParallel Redundant UPS withBypass as data sheet DS-440 575 1X100% NI-CD Battery Bank for 30 Min. backup along with all accessories & battery Isolator. 576 230V, 300 Amps, 50 Hz, AC Distribution Board as per Feeder Details listed in scope of work/job specification 577 Cell booster of adequate rating suitable for battery AH capacity. 578 Providing training to 2 nos. owners engineer at Vendor Works for a period of min. 3 days for 55KVA UPS system 579 Providing training to 5 nos. owners engineers at site for 55KVA UPS system 580 Mandatory spares for 230V, 55KVA UPS system as perCl.6.1 (Mandatory spares), sr.no.10 of EDB document no. B861-000-16-50-EDB-1001 581 MISCELLANEOUS CONTROL GEAR 582 Installation, testing and commissioning of miscellaneous surface mounted industrial/FLP control gear such as lighting/power panel, push button stations, motor starter, communication equipment, junction boxes, panels, plugs, sockets, including supply of necessary hardware, touch up painting including supply of paint, including transportation from store/yard to site at the place of installation, unpacking, (excluding fixing of cable glands and cable terminations),including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 583 Weight of the unit above 5 kg. but upto 20 kg. 584 Weight of the unit above 20 kg. but upto 100 kg. 585 Weight of the unit up to 5 kg. 586 Supply of Industrial, weather proof type Push Button stations as per EIL specification No. 6-51-0014, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 587 With stop (latching type) push button. 588 With stop (non-latching type) push button. 589 With start and stop (latching type) push buttons. 590 With start, stop push buttons and ammeter. 591 With start,stop push buttons and one Three position selector switch. 592 With start,stop push buttons, one Three position selector switch and ammeter. 593 With stop push button (Break Glass Type). 594 With start and stop (non-latching type) push buttons. 595 Supply of flameproof and weather proof type Push Button station as per EIL standard specification No. 6-51-0006 as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 596 With start, stop push buttons and one Three position selector switch and ammeter. 597 DC SYSTEM / BATTERY BANK 598 Supply of following ratings of Nickel-cadmium batteries, battery charger, distribution board alongwith accessories as per EIL specification No. 6-51-0019, 6-51-0047, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 599 160A (Min.) , dual redundant battery charger as per data sheet DS-430 600 110V, 1x500AH(Min.), Ni-Cd battery bank 601 110V, 350A DC distribution board as per feeder details listed in scope of work/job specification 602 3P MCCB / DC Circuit Breaker Battery isolator in weatherproof enclosure(IP-55)of adequate rating. 603 Mandatory spares for 110V Battery & Battery charger as per Cl.6.1 (Mandatory spares), sr.no.11 of EDB document no. B861-000-16-50-EDB-1001 604 Installation, testing and commissioning of stationary nickel-cadmium battery banks of the following ratings, including transportation from store/yard to site at the place of installation, filling with electrolyte, charging and dischargng of cells, including capacity test etc., aligning, levelling, grouting, assembly of battery racks, fixing of inter-cell connectors etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 605 Nickel-cadmium battery banks (including capacity test) rated for 110 V500 Ah 606 Supply of following rating of cell boosters as per EIL specification No. 6-51-0019, including all labour and materials, as per data sheets, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 607 Cell booster rated for 12 V50 A 608 PLUGS, SOCKETS AND JUNCTION BOXES 609 Supply of weatherproof metal clad 415V, TPN, industrial type socket and plug with heavy duty interlocking switch, with adequately sized cable adaptor box for incoming and outgoing cable terminations, including supply of double compression brass nickel plated cable glands, tinned copper lugs,including all labours and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 610 63 A, 415 V, 5 pin sockets along with associated 5 pin plugs. 611 240 V, 15 A, 3 pin sockets. 612 240 V, 15 A, 3 pin sockets along with associated 3 pin plugs. 613 24 V, 5 A, 3 pin sockets along with associated 3 pin plugs. WITH TRANSFORMER.(240/24V) 614 Supply, installation, cable termination, connection, testing and commissioning of following types of FLP andWP junction boxes, as per EIL specification No. 6-51-0061, including all labours and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 615 WP JB (IP-65) with 15 A, 16 terminals suitable for 1 No. incoming and6 Nos. outgoing cable entries complete with cable glands for incoming and outgoing cables and 3 Nos. blocking plugs 616 WP 3 way JB (IP-65) complete with 3 Nos. cable glands and 1 Nos. blocking plug suitable for cables upto 3 x 2.5 sq. mm YWY / XWY cable. 617 WP 4 way JB with IP-65 degree of protection complete with 4 Nos. cable glands and 2 Nos. blocking plug suitable for cables upto 3 x 2.5 sq. mm YWY / XWY cable. 618 NEUTRAL GROUNDING RESISTOR 619 Supply of following rating of outdoor type neutral grounding resistor, as per EIL standard specification no.6-51-0043,including all labour and materials, as per approved drawings, specifications of this tnder and directions of Engineer-in-Charge. 620 NGR rated for 3.81 kV400 A 621 Installation, testing and commissioning of outdoor type following neutral grounding resistor consisting of cast iron/stainless steel grid resistor with/without neutral CT including connection of one end of resistor with transformer neutral and the other end of the resistor to the earthing grid, including transportation from store/yard to site at the place of installation, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 622 NGR rated for 3.81 kV400 A 623 CAPACITOR BANKS 624 Supply of following HV capacitor banks, series reactor and RVT, as per EIL standard specification NO. 6-51-0020, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 625 11kV, 3 Phase,indoor type APFC panel -1500kVAR 626 Mandatory spares for APFC as per Cl.6.1 (Mandatory spares), sr.no.20 of EDB document no. B861-000-16-50-EDB-1001 627 Installation of following H.V. capacitor banks,series reactor and RVT, including transportation from store/yard to site ofinstallation, unpacking, assembly of elevating structure, interconnection of loose parts supplied by equipment vendor, aligning, levelling etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 628 HV capacitor banks rated for 1500 kVAR11 kV 629 Testing and commissioning of following H.V. capacitor banks,series reactor and RVT, including testing equipments, all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 630 HV capacitor banks rated for 1500 kVAR11 kV 631 CANOPIES 632 Supply, fabrication and installation of FRP canopies for outdoor electrical miscellaneous equipments such as lighting/power panels and distribution junction boxes, local panels , PB stations etc. to render them weather proof including supply of necessary hardware for fixing and clamping with the equipment, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 633 Lighting Panel/Power panel/distribution junctions boxes. 634 Manual call points/field call stations. 635 Push button stations. 636 Supply, fabrication andinstallation of canopies for miscellaneous outdoor equipment like motors, fire alarm points, telephones, communication hand set stations etc. to render them weatherproof made out of 1.6 mm (16 gauge) sheet steel including supply of hardware and paint, painting, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 637 Supply, fabrication andinstallation of GI canopies for outdoor electrical motors of following frame sizes to render them weather proof including supply of necessary hardware for fixing and clamping with the motor foundation, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 638 Frame size upto 80. 639 Frame size more than 80 and upto 112. 640 Frame size more than 112 and upto 180. 641 Frame size more than 180 and upto 250. 642 Supply, fabrication and installation of GI canopies for outdoor electrical miscellaneous equipments such as lighting/power panels and distribution junction boxes, local panels , PB stations etc. to render them weather proof including supply of necessary hardware for fixing and clamping with the equipment, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 643 Lighting Panel/Power panel/distribution junctions boxes. 644 Manual call points/field call stations. 645 Push button stations. 646 FLP receptacles. 647 ANCHOR FASTENERS 648 Supply, drilling in RCC and fixing of metallic anchor fasteners for supporting of cable trays and miscellaneous electrical switchgear of following sizes, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 649 3/16 BSW. 650 5/16 BSW. 651 1/4 BSW. 652 3/8 BSW. 653 5/8 BSW. 654 1/2 BSW. 655 SAFETY EQUIPMENT 656 Supply and installation of the following, including the supply of necessary clamps, bolts, rawl plugs etc., breaking and making good of walls, if required, mounting, including all labour and materials, complete and as per applicable standards and CEA Guidelines and as per directions of Engineer-in-Charge. 657 Shock hazard charts complete with frame and glass. 658 First Aid Boxes. 659 4.5 kg capacity CO2 type fire extinguishers. 660 6.8 kg capacity CO2 type fire extinguishers. 661 9 kg capacity CO2 type fire extinguishers. 662 Sand buckets with stand (Each with at least 3 sand buckets). 663 Shock hazard charts - Laminated type 664 Gas Mask for use in substation during fire & smoke as per CEA guidelines 665 Supply and laying of 900 mm wide safety insulation mats complying to IS-15652, of following grades required for maintenance of electrical equipment in substation, including cutting to required shape in running length, including all labour and materials, as per applicable Indian or International standards and CEA Guidelines and as per directions of Engineer-in-Charge. 666 3.3 kV grade. 667 11 kV grade. 668 Supply of following items as per applicable Indian standards/CEA Guidelines. 669 Rubber hand gloves (11 kV grade). 670 Rubber hand gloves (33 kV grade). 671 Enamelled caution boards. 672 Discharge rod with earthing facility (upto 11 kV grade). 673 HV fuse puller handle. 674 Supply and application/installation of epoxy based insulation coating with breakdown voltage as per IS, suitable for system voltage as marked and shall be suitable for installation on concrete flooring of substation in airconditioned/non-airconditioned area, having smooth finish, including all labour and materials, complete as per approved drawings, job & standard specification attached with this tender and directions of the engineer-in- charge 675 For highest systen voltage of 12.1kV 676 SUPPLY OF SPARES / LAMPS 677 MV HRC Fuses 678 16 A. 679 32 A. 680 63 A. 681 100 A. 682 160 A. 683 250 A. 684 SUPPLY OF MV CABLES 685 Supply of 1100 V grade, Copper Conductor,XLPE insulated and armoured, cables of following sizes as per EIL standard specification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 686 2 C x 10 sq. mm 687 2C x 16 sq. mm 688 2 C x 2.5 sq. mm 689 3 C x 6 sq. mm 690 2 C x 4 sq. mm 691 3 C x 4 sq. mm 692 3 C x 10 sq. mm 693 3 C x 2.5 sq. mm 694 Supply of 1100 V grade, Aluminium Conductor, XLPE insulated and armoured, cables of following sizes as per EIL standard specification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 695 3 C x 25 sq. mm 696 3.5 C x 25 sq. mm 697 3 C x 35 sq. mm 698 2 C x 50 sq. mm 699 3 C x 95 sq. mm 700 3 C x 120 sq. mm 701 3.5 C x 185 sq. mm 702 3 C x 240 sq. mm 703 3 C x 50 sq. mm 704 3.5 C x 35 sq. mm 705 3.5 C x 95 sq. mm 706 3.5 C x 300 sq. mm 707 3.5 C x 50 sq. mm 708 3.5 C x 120 sq. mm 709 Supply of 1100 V grade, Copper Conductor, Individual pair shielded & Overall shielded, twisted pair/triad, XLPE insulated, Armored, FRLS outer-sheathed cables of following sizes as per EIL standard specification No. 6-51-0052, data sheets, specifications of this tender and directions of Engineer-in-Charge. 710 1 Pair x 2.5 sq. mm 711 2 Pair x 2.5 sq. mm 712 4 Pair x 2.5 sq. mm 713 6 Pair x 2.5 sq. mm 714 12 Pair x 2.5 sq. mm 715 SUPPLY OF HV CABLES (MULTI CORE) 716 Supply of 6.6 kV (UE) grade, Al/Cu Conductor, XLPE insulated and armoured cables of following sizes as per EIL standard specification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 717 3 C x 240sq. mm, Al 718 Supply of 11 kV (UE) grade, Al/Cu Conductor, XLPE insulated and armoured cables of following sizes as per EIL standardspecification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 719 3 C x 240 sq. mm, Al 720 3 C x 300 sq. mm, Al 721 SUPPLY OF HV CABLES (SINGLE CORE) 722 Supply of 6.6 KV (UE) grade, Al/Cu Conductor, XLPE insulated and armoured single core cables of following sizes as per EIL standard specification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 723 1 C x 630 sq. mm, Al 724 Supply of 11 KV (UE) grade, Al/Cu Conductor, XLPE insulated and armoured single core cables of following sizes as per EIL standard specification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 725 1 C x 630 sq. mm, Al 726 LAYING OF CABLES 727 Laying of cables of different voltage grade and types of the following overall diameters in ready trays/trenches/ supported on structure/pull through pipes including supply and fixing of stainless steel strip number tags, supply and fixing of GI saddles & saddle bars, trefoil clamps (for single core cables) etc., including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge 728 Cables with OD above 80 mm but upto 100 mm. 729 Cables with OD above 50 mm but upto 60 mm. 730 Cables with OD above 60 mm but upto 80 mm. 731 Cables with OD above 30 mm but upto 40 mm. 732 Cables with OD above 20 mm but upto 30 mm. 733 Cables with OD upto 20 mm. 734 Cables with OD above 40 mm but upto 50 mm. 735 Laying of cables (using cable pulling by motorized winch with torque limits) of different voltage grade and types of the following overall diameters in ready trays/trenches/supported on structure/pull through pipes including supply and fixing of stainless steel strip number tags, supply and fixing of GI saddles & saddle bars, trefoil clamps (for single core cables) etc., including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge 736 Cables with OD upto 20 mm. 737 Cables with OD above 20 mm but upto 30 mm. 738 Cables with OD above 30 mm but upto 40 mm. 739 Cables with OD above 40 mm but upto 50 mm. 740 Cables with OD above 50 mm but upto 60 mm. 741 Cables with OD above 60 mm but upto 80 mm. 742 Cables with OD above 80 mm but upto 100 mm. 743 END TERMINATIONS 744 Fire proofing of cables including supply of all fire proofing paint, including all labour and materials, as per IEC-60331, specifications of this tender and directions of Engineer-in- Charge. (Actual area of surface painted shall be measured). 745 Supply of Unearthed grade H.V. termination kits of (indoor/outdoor type) as per EIL standard specification No. 6-51-0051, excluding cable glands and lugs, as per approved drawings and as per specifications of this tender and directions of Engineer-in-Charge. 746 3 Core cable Indoor termination kit for 6.6 kV240 mm² 747 3 Core cable Outdoor termination kit for 6.6 kV240 mm² 748 3 Core cable Indoor termination kit for 6.6 kV300 mm² 749 3 Core cable Indoor termination kit for 11 kV300 mm² 750 3 Core cable Indoor termination kit for 11 kV240 mm² 751 1 Core cable Indoor termination kit for 6.6 kV630 mm² 752 1 Core cable Indoor termination kit for 11 kV630 mm² 753 Termination of Unearthed grade HV cables and connection of leads including fixing of cable glands,supply and fixing of PVC shrouds for outdoor terminations, cutting and stripping of cable insulation, crimping the lug onto the conductor, restoration of the insulation, clamping of cable cores and earthing of armour, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. (Excluding supply of termination kits and cable glands). 754 3 Core cable termination kit for 6.6 kV300 mm² 755 3 Core cable termination kit for 6.6 kV240 mm² 756 3 Core cable termination kit for 11 kV300 mm² 757 3 Core cable termination kit for 11 kV240 mm² 758 1 Core cable termination kit for 6.6 kV630 mm² 759 1 Core cable termination kit for 11 kV630 mm² 760 Termination of XLPE insulated armoured power cables (up to 1100 V grade) and connection of leads excluding the supply of cable glands and lugs but includingfixing of cable glands, supply and fixing of PVC shrouds for outdoor terminations, cutting and stripping of cable insulation, crimping the lug on to the conductor, clamping of the cable-cores, marking with wire number, ferrules etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 761 Cables with OD above 60 mm but upto 80 mm. 762 Cables with OD above 40 mm but upto 50 mm. 763 Cables with OD above 30 mm but upto 40 mm. 764 Cables with OD above 50 mm but upto 60 mm. 765 Cables with OD upto 20 mm. 766 Cables with OD above 20 mm but upto 30 mm. 767 Termination of communication, fire alarm & control paired cables and connection of leads excluding the supply of cable glands and lugs but including fixing of cable glands, supply and fixing of PVC shrouds for outdoor terminations,cutting, stripping of cable insulation, crimping the lug on to the conductor, clamping of the cable- cores, marking with wire number, ferrules etc., including all labour and materials,as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 768 All sizes from 1P to 4P and upto 2.5 sq. mm 769 All sizes from 5P to 10P and upto 2.5 sq. mm 770 All sizes from 11P to 15P and upto 2.5 sq. mm 771 STRAIGHT THROUGH JOINTS 772 Supply and Making of heat shrinkable type straight through joints for 1100 volt grade power cablesas per EIL standard specification No. 6-51-0051, including cutting, stripping of cable insulation complete with supply of compression / crimping type ferrules, plastic mould and epoxy resin compound etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 773 Cables with OD above 30 mm but upto 40 mm. 774 Cables with OD above 50 mm but upto 60 mm. 775 Cables with OD above 60 mm but upto 80 mm. 776 Cables with OD upto 20 mm. 777 Cables with OD above 40 mm but upto 50 mm. 778 Cables with OD above 20 mm but upto 30 mm. 779 Supply of heat shrinkable type Straight through jointing kits for Unearthed grade H.V. cables of the following sizes,as per EIL standard specification No. 6-51-0051, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 780 3 Core cable Straight through jointing kits for 6.6 kV240 mm² 781 3 Core cable Straight through jointing kits for 11 kV300 mm² 782 1 Core cable Straight through jointing kits for 6.6 kV630 mm² 783 1 Core cable Straight through jointing kits for 11 kV630 mm² 784 Making of Straight through joints for H.V. cables of following sizes excluding supply of jointing kit and accessories, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 785 3 Core cable Straight through jointing kits for 6.6 kV240 mm² 786 3 Core cable Straight through jointing kits for 11 kV300 mm² 787 1 Core cable Straight through jointing kits for 6.6 kV630 mm² 788 1 Core cable Straight through jointing kits for 11 kV630 mm² 789 Supply and Making of heat shrinkable type straight through joints for communication, fire alarm & control paired cables, including cutting, stripping of cable insulation complete with supply of compression / crimping type ferrules, plastic mould and epoxy resin compound etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 790 All sizes from 5P to 10P and upto 2.5 sq. mm 791 All sizes from 11P to 15P and upto 2.5 sq. mm 792 All sizes from 1P to 4P and upto 2.5 sq. mm 793 G.I. & PVC PIPES 794 Supply and laying of following sizes ofG.I. Pipes (medium) in required length fixed on steel, concrete or similar structure, laid in trenches, ready to be buried in concrete including cutting, threading, bending and similar works, supply of clamps, small iron structures, spacers and installation of seats, plugs, bushings etc., small civil works, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 795 100 mm NB. 796 150 mm NB. 797 50 mm NB. 798 STRUCTURAL STEEL 799 Supply, fabrication, galvanising andinstallation of base frames, supports for switchgear, and brackets for miscellaneous electrical equipments, cable and cable tray supports out of rolled MS sections, pipes, plates etc. including welding, bolting, rivetting, supply of necessary anchor bolts and grouting etc., including breaking walls, floors etc. for structures as required including supply of all GI hardware materials, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. (Any item weighing up to 1 kg. or less shall neither be measured nor paid). 800 CABLE - TRAYS 801 Supply and installation of prefabricated hot dip galvanised steel cable trays, fabricated out of hot rolled sheet steel with rigid welded construction ladder type with a rung as per std. 7-51-0333, of approved make and cable tray fittings, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 802 Reducers 750 - 450 RHS. 803 Reducers 750 - 600 RHS. 804 Reducers 750 - 600 LHS. 805 Horizontal bends for 450 mm wide tray with 1000 mm bending radius. 806 Horizontal bends for 600 mm wide tray with 1000 mm bending radius. 807 Vertical outside bends for 450 mm wide tray with 1000 mm bending radius. 808 Vertical outside bends for 600 mm wide tray with 1000 mm bending radius. 809 Vertical inside bends for 600 mm wide tray with 1000 mm bending radius. 810 Tee Joints for 450 mm wide tray with 1000 mm bending radius. 811 Tee Joints for 600 mm wide tray with 1000 mm bending radius. 812 Tee Joints for 750 mm wide tray with 1000 mm bending radius. 813 Cross Joints for 450 mm wide tray with 1000 mm bending radius. 814 Cross Joints for 750 mm wide tray with 1000 mm bending radius. 815 Vertical inside bends for 750 mm wide tray with 1000 mm bending radius. 816 300 mm wide Straight run cable tray. 817 Horizontal bends for 750 mm wide tray with 1000 mm bending radius. 818 Vertical outside bends for 750 mm wide tray with 1000 mm bending radius. 819 600 mm wide Straight run cable tray. 820 Reducers 750 - 300 RHS. 821 Reducers 600 - 300 RHS. 822 Horizontal bends for 300 mm wide tray with 1000 mm bending radius. 823 Vertical outside bends for 300 mm wide tray with 1000 mm bending radius 824 Vertical inside bends for 300 mm wide tray with 1000 mm bending radius 825 Tee Joints for 300 mm wide tray with 1000 mm bending radius. 826 450 mm wide Straight run cable tray. 827 750 mm wide Straight run cable tray. 828 Supply and installation of following galvanised slotted channel trays of 2 mm thickness and 50 mm high for supporting cables, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 829 150 mm wide. 830 60 mm wide. 831 100 mm wide. 832 Supply, fabrication andinstallation of 0.91 mm (20 gauge) GI sheet covers for cable trays, including necessary hardwares, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 833 CABLE GLANDS 834 Supply of nickel-plated, flame proof IIA/IIB double compression type brass cable glands, suitable for out door terminations of armoured PVC cables of following overall diameter (excluding termination and connection of cables), including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 835 Cables with OD above 50 mm but upto 60 mm. 836 Cables with OD above 30 mm but upto 40 mm. 837 Cables with OD above 40 mm but upto 50 mm. 838 Cables with OD above 60 mm but upto 80 mm. 839 Cables with OD above 20 mm but upto 30 mm. 840 Cables with OD upto 20 mm. 841 Supply of nickel plated brass double compression cable glands suitable for outdoor installations (WP) of following overall diameter (excluding termination and connections of cables), including drilling of suitable holes in equipments for fixing purposes etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 842 Cables with OD upto 20 mm. 843 Cables with OD above 20 mm but upto 30 mm. 844 Cables with OD above 30 mm but upto 40 mm. 845 Cables with OD above 40 mm but upto 50 mm. 846 Cables with OD above 50 mm but upto 60 mm. 847 Cables with OD above 60 mm but upto 80 mm. 848 Supply of nickel plated brass single compression cable glands of following overall diameter (excluding termination and connections of cables), including drilling of suitable holes in equipments for fixing purposes etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 849 Cables with OD upto 20 mm. 850 Cables with OD above 20 mm but upto 30 mm. 851 Cables with OD above 30 mm but upto 40 mm. 852 Cables with OD above 40 mm but upto 50 mm. 853 Cables with OD above 50 mm but upto 60 mm. 854 Cables with OD above 60 mm but upto 80 mm. 855 Cables with OD above 80 mm but upto 100 mm. 856 Supply and fixing of FLP(IIA/IIB) blocking plugs for blocking unused cable entries with following diameter in outdoor electrical equipment including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 857 Cables with OD above 60 mm but upto 80 mm 858 Cables with OD above 30 mm but upto 40 mm 859 Cables with OD above 40 mm but upto 50 mm 860 Cables with OD above 50 mm but upto 60 mm 861 Cables with OD up to 20 mm 862 Cables with OD above 20 mm but upto 30 mm 863 MARKERS 864 Supply and installation of earth pit markers for directly buried GI pipe electrodes as per std. 7-51-0101 with 14 SWG enamelled steel plate engraved with white letters BURIED, EARTH ELECTRODE on JADE green background complete with support and foundation, including all labour and materials, as per approved drawings, specifications of this tender and direction of Engineer-in-Charge. 865 Supply and installation of cable markers as per std. 7-51-0301, for underground cable runs with 14 SWG enamelled steel plate with white lettering on jade green background inclusive of providing and fixing supports, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 866 CABLE LUGS 867 Supply of crimping type long barrel tinned copper lugs with circular/sector shaped barrel for following conductor sizes, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 868 All sizes from 50 to 185 sq. mm 869 All sizes from 16 to 35 sq. mm 870 All sizes from 240 to 400 sq. mm 871 All sizes upto 10 sq. mm 872 All sizes from 500 to 1000 sq. mm 873 Supply of crimping type long barrel aluminium lugs with circular/sector shaped barrel for following conductor sizes, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 874 All sizes upto 10 sq. mm 875 All sizes from 240 to 400 sq. mm 876 All sizes from 16 to 35 sq. mm 877 All sizes from 50 to 185 sq. mm 878 All sizes from 500 to 1000 sq. mm 879 Supply of crimping type long barrel Bimetallic lugs with Al barrel & tinned Cu palm with circular/sector shaped barrel for following conductor sizes, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 880 All sizes from 50 to 185 sq. mm 881 All sizes from 240 to 400 sq. mm 882 All sizes upto 10 sq. mm 883 All sizes from 16 to 35 sq. mm 884 All sizes from 500 to 1000 sq. mm 885 Supply of crimping type long barrel Bimetallic lugs with tinned Cu barrel & Al palm with circular/sector shaped barrel for following conductor sizes, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 886 All sizes upto 10 sq. mm 887 All sizes from 16 to 35 sq. mm 888 All sizes from 240 to 400 sq. mm 889 All sizes from 50 to 185 sq. mm 890 All sizes from 500 to 1000 sq. mm 891 FIRE PROOFING OF CABLES 892 Fire proofing of cables including supply of all fire proofing paint, including all labour and materials, as per specifications of this tender and directions of Engineer-in-Charge. (Actual area of surface painted shall be measured). 893 ADAPTORS / REDUCERS / NIPPLES ETC. 894 Supply and fixing nickel-plated brass adaptors/ reducers for cable glands of following sizes including all labour and materials complete as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. Adaptors shall have male part threaded as per Eqpt. threads and the other end to receive glands having E.T. thread. 895 Eqpt. Thread 3/4 PF (J.I.S.)-E.T. Thread 3/4ET 896 Eqpt. Thread 1 PF (J.I.S.) - E.T. Thread 3/4ET 897 Eqpt. Thread 1 PF (J.I.S.) -E.T. Thread 1ET 898 Eqpt. Thread 1-1/2 PF (J.I.S.)- E.T. Thread 1-1/4ET 899 Eqpt. Thread 1-1/2 PF (J.I.S.)- E.T. Thread 1-1/2ET 900 Eqpt. Thread 2 PF (J.I.S.) -E.T. Thread 1-1/2ET 901 Supply and installation of GI reducers/enlargers of following sizes for cable glands of following sizes including all labour and materials complete as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. Adaptors shall have male part threaded as per Eqpt. threads and the other end to receive glands having E.T. thread. 902 Eqpt. Thread PG 13.5(DIN) - E.T. Thread 3/4 ET 903 Eqpt. Thread PG 16 (DIN) -E.T. Thread 3/4 ET 904 Eqpt. Thread PG 21 (DIN) -E.T. Thread 1ET 905 Eqpt. Thread PG 29 (DIN) -E.T. Thread 1-1/2 ET 906 Eqpt. Thread 1 ET (IS) -E.T. Thread 3/4 ET 907 Eqpt. Thread 1-1/2 ET (IS) -E.T. Thread 1 ET 908 Eqpt. Thread 1-1/2 ET (IS) -E.T. Thread 1-1/2 ET 909 Eqpt. Thread 2 ET (IS) -E.T. Thread 1-1/2 ET 910 Supply and fixing FLP(IIA/IIB), weatherproof, nickel-plated brass adaptors/reducers for cable glands of following sizes including all labour and materials complete as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. Adaptors shall have male part threaded as per Eqpt. threads and the other end to receive glands having E.T. thread. 911 Eqpt. Thread 3/4 PF (J.I.S.)-E.T. Thread 3/4ET 912 Eqpt. Thread 1 PF (J.I.S.) -E.T. Thread 3/4ET 913 Eqpt. Thread 1 PF (J.I.S.) -E.T. Thread 1ET 914 Eqpt. Thread 1-1/2 PF (J.I.S.)- E.T. Thread 1-1/4ET 915 Eqpt. Thread 1-1/2 PF (J.I.S.)- E.T. Thread 1-1/2ET 916 Eqpt. Thread 2 PF (J.I.S.) -E.T. Thread 1-1/2ET 917 Supply and installation of FLP(IIA/IIB) GI reducers/ enlargers of following sizes for cable glands of following sizes including all labour and materials complete as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. Adaptors shall have male part threaded as per Eqpt. threads and the other end to receive glands having E.T. thread. 918 Eqpt. Thread PG 13.5(DIN) - E.T. Thread 3/4 ET 919 Eqpt. Thread PG 16 (DIN) -E.T. Thread 3/4 ET 920 Eqpt. Thread PG 21 (DIN) -E.T. Thread 1ET 921 Eqpt. Thread PG 29 (DIN) -E.T. Thread 1-1/2 ET 922 Eqpt. Thread 1 ET (IS) -E.T. Thread 3/4 ET 923 Eqpt. Thread 1-1/2 ET (IS) -E.T. Thread 1 ET 924 Eqpt. Thread 1-1/2 ET (IS) -E.T. Thread 1-1/2 ET 925 LIGHTING POLES 926 Supply and installation of Lighting Poles for floor mounting as per std. 7-51-0201, including all civil works, excavation, foundation, disposal of surplus earth, providing shoring, strutting and dewatering if required and including supply of cement, steel, GI pipes, base plates, paint and all sundry materials as required, including painting, (excluding supply and installation of control gear box/junction box), but including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 927 Lighting poles including supply and connection of wires upto fixtures for safe areas. 928 Supply andinstallation of platform Lighting pole as per std. 7-51-0202,including all welding, structural works, paint and all sundry materials as required, including painting, (excluding supply and installation of control gear box/junction box), but including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 929 Lighting poles including supply and connection of wires upto fixtures for safe areas. 930 Supply andinstallation of street lighting poles (single bracket/double bracket) including built in marshalling box andnecessary wire/cable running from marshalling box to the lighting fixture, cable termination and connection, fixing of cable glands and lugs,including all civil works, excavation, foundation, disposal of surplus earth, providing shoring, strutting and dewatering if required and including supply of cement, steel, GI pipes, base plates, paint and all sundry materials as required, including painting, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 931 Poles as per std. 7-51-0233 with MB as per 7-51-0208 for safe area 932 Poles as per std. 7-51-0234 sht. 2 of 2 (Single bracket) 933 HAZARDOUS AREA LIGHTING FIXTURES AND ACCESSORIES 934 Installation, connection, testing and commissioning of following types of flame proof/Div.2 lighting fixtures and accessories, including cable termination and connection, fixing of cable glands, lugs, including supply of necessary hardwares, including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 935 3-way, junction box. 936 4-way, junction box. 937 Well glass type pole mounting type for Ground Level. 938 Well glass type ceiling mounted. 939 Well glass type bracket mounted. 940 Well glass type pole mounting type for Platform. 941 Supply and installation of Type-`A clamps(for bracket mounted lighting fixtures) including bolt (MOC SS304) for fixing the fixture to the clamp as per EIL std.no.7-51-0221, including supply and fixing of anchor fasteners, nuts and bolts, washers etc. as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 942 Supply and installation of adapters for Platform and ground pole mounted lighting fixtures as per EIL std.no.7-51-0221, approved drawings, specifications of this tender and directions of Engineer-in-Charge. 943 Supply and installation of Type-`B clamps(for ceiling mounted lighting fixtures) including bolt (MOC SS304) for fixing the fixture to the clamps per EIL std.no.7-51-0221, including supply and fixing of anchor fastners,nuts and bolts,washers as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 944 SAFE AREA LIGHTING FIXTURES 945 Supply, installation, testing and commissioning of following energy efficient lighting fixtures and connecting to wiring junction box/marshalling box complete with lamps and necessary control gear including supply of all connected materials like flexible conduit, clamps, supports, chains, anchor fastners, bolts, nuts and washers etc. as required, including supply and fixing of cable glands, lugs, including all labour and materials, as per approved drawings, data sheet for lighting fixture schedule, EIL installation standards, specifications of this tender and directions of Engineer-in-Charge. 946 Type LED SFD-12 Fixtures. 947 Type LED BK-3 Fixtures. 948 Type LED ST-10 Fixtures. 949 Type LED FD-1 Fixtures. 950 Type LED FD-2 Fixtures. 951 Type LED FD-3 Fixtures. 952 JUNCTION BOXES (OUTDOOR / INDOOR TYPE) 953 Supply and installation of dust and vermin proof G.I. sheet steel (1.6 mm thick) junction box WP type suitable for outdoor/indoor installation with number of outgoing ways as under, complete with PVC connectors, supply and fixing of cable glands, including supply of required size and number of terminals, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 954 3 way. 955 4 way. 956 LIGHTING / POWER PANELS AND DISTRIBUTION BOARDS 957 Supply, installation, connection, testing and commissioning offlame proof weather proof lighting/power panels(for gas group IIA/IIB) as per EIL std. spec. 6-51-0008, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 958 40 A, 4 pole incomer MCB isolator and 12 Nos. outgoingdouble poleMCBs with ELCB (upto 20 A). 959 40 A, 4 pole incomer MCB isolator and 6 Nos. outgoingdouble poleMCBs with ELCB (upto 20 A). 960 Supply, installation, connection, testing and commissioning of safe area lighting/power panels, surface/flush mounting type, wall mounting type in dust tight (with hinged cover) sheet steel enclosure having 4 pole incomer and single pole MCB (9 kA type) for outgoing circuit control with completewiring, including cable termination, connection and fixing of cable glands, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 961 40 A, 4 pole incomer MCB isolator and 6 Nos. outgoingdouble poleMCBs (upto 20 A) with RCCBs in each outgoing circuits suitable for outdoor location with IP-65 degree of protection 962 40 A, 4 pole incomer MCB isolator and 12 Nos. outgoingdouble poleMCBs (upto 20 A) with RCCBs in each outgoing circuits suitable for outdoor location with IP-65 degree of protection 963 63 A, 4 pole incomer MCB isolator and 18 Nos. outgoingdouble poleMCBs (upto 20 A) with RCCBs in each outgoing circuits suitable for outdoor location with IP-65 degree of protection 964 WIRING 965 Circuit wiring in non-hazardous areas using (size given below), copper conductor, PVC insulated, FRLS outer sleeve cables (third core for earthing),from lighting/powerpanel/distribution junction box, excluding the supply of cable, junction boxes and cable glands but including termination and connection, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 966 3 C x 2.5 sq. mm 967 3 C x 4 sq. mm 968 Circuit wiring in hazardous areas using (sizes given below) copper conductor, XLPE insulated, FRLS outer sleeve armoured cables (third core for earthing) from lighting/power panel/distribution junction box onwards, excluding the supply of cables, junction boxes and cable glands but including fixing of cable glands, supply and fixing of clamps, cable terminations and connections, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 969 3 C x 2.5 sq. mm 970 EARTH ELECTRODES 971 Supply, installation, testing and commissioning of GI earth electrodes, complete with earth pit as per std. 7-51-0102 and all necessary materials including excavation of earth pit, filling with charcoal and salt, back filling, providing necessary brickwork, connections, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 972 GI earth electrode as per std. 7-51-0102. 973 COPPER EARTH ELECTRODES 974 Supply, installation, testing and commissioning of Cu earth electrodes complete with 38 mm outer dia x 3 mm thick Cu pipe in a depth of 25Mtr, 3mm Thick 4Inch X 12 Inch Copper plate, earth pit and all necessary materials including excavation of earth pit, filling with charcoal and salt, bentonite powder, back filling, providing necessary brickwork, connections, including all labour and materials, as per sketch B861-000-16-50-DS-4001, approved drawings, specifications of this tender and directions of Engineer-in-Charge 975 EARTH STRIPS 976 Supply, installation and connection of following GI earthing strip along the cable trenches or cable trays or fixing to walls or structures including welding at joints, providing anti-corrosive paint or bitumen and jute covering for welded portion, clamping and necessary hardware for connecting, etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 977 100 X 12 mm 978 40 x 5 mm 979 25 x 3 mm 980 50 x 6 mm 981 Supply, installation and connection of following GI earthing strip buried individually at a depth of 500 mm including welding at joints, providing anti-corrosive paint or bitumen and jute covering for welded portion, clamping and necessary hardware for connecting, excavation and refilling etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 982 100 X 12 mm 983 40 x 5 mm 984 25 x 3 mm 985 50 x 6 mm 986 EARTHING CONNECTION 987 Connecting individual equipment to the earth strip or earth plate with following sizes of G.I. wire / G.I. wire rope including the supply of G.I. wire /G.I. wire rope, lugs, conductors, connecting to the G.I. strip or earth plate and necessary hardware for connection, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 988 3/8 dia (10 mm) flexible rope. 989 5/8 dia (16 mm) flexible rope. 990 8 SWG GI Wire. 991 Supply and installation of 25 sq. mm (168/0.01772) copper flexibles of following length with copper lugs crimped on both sides for earthing of pipeline vessels, equipments (non electrical) as per std. 7- 51-0112, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 992 300 mm 993 500 mm 994 1500 mm 995 EARTH PLATES 996 Supply, installation and connection of GI earth plates as per std. 7-51-0103, complete with anchor bolts, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 997 GI earth plate as per std. 7-51-0103. 998 EARTHING CONNECTORS 999 Supply and installation of MS ear of width 50 mm and thickness 5 mm for earthing of process vessels, steel structures, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1000 Minimum 75mm to maximum 300 mm long 1001 Supply and installation of stainless steel ear of width 50 mm and thickness 5 mm for earthing of process vessels, steel structures, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1002 Minimum 75mm to maximum 300 mm long 1003 LIGHTNING RODS 1004 Supply and installation of GI lightning rod as per std. 7-51-0503 including supply of all hardware etc., including all labour and materials,as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1005 GI lightning rod as per std. 7-51-0503. 1006 LAYING OF COMMUNICATION / FIRE ALARM CABLES 1007 Horizontal and vertical laying/pulling through of communication/fire alarm cables of the following overall diameters in ready trays/trenches/conduits or supported on structures including supplying and fixing of GI saddle and saddle bars, stainless steel strip number tags, including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge 1008 Cables of overall dia. above 35 mm. 1009 Cables of overall dia. upto 35 mm. 1010 Laying of HDPE ducts for laying of optical fiber cables between various substations, pulling through pipes or supported on structures including supplying and fixing of GI saddle and saddle bars, including supply and fixing of printed stainless steel/ non magnetic non corrosive metal tags, including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge 1011 HDPE duct with overall dia. Upto 60mm 1012 HDPE duct with overall dia. above 60mm 1013 Laying of optical fiber cables between various buildings in already laid HDPE conduits for plant communication and fire alarm data highway, feeder differential protection, etc., including supply of all hardware, splice connectors, accessories, pulling through pipes or supported on structures including supply and fixing of printed stainless steel/ non magnetic non corrosive metal tags, including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1014 Cables of overall dia. upto 40 mm. 1015 Cables of overall dia. above 40 mm. 1016 STRAIGHT THROUGH JOINTS COMMUNICATION / FIRE ALARM CABLES 1017 Making of straight through joints for polyethylene insulated armoured jelly filled/ non filled overall PVC jacketed, including supply of all necessary materials for the joint, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1018 For Non-Jelly filled cables of size .9 mm5 pair 1019 For Non-Jelly filled cables of size .9 mm20 pair 1020 For Non-Jelly filled cables of size .9 mm10 pair 1021 For Jelly filled cables of size .63 mm²20 pair 1022 For Non-Jelly filled cables of size 1.5 mm²2 pair 1023 Supply of straight through jointing kit for Mono mode, multitube/unitube, jelly filled, Optical fiber cable with non metallic armour with following number of fibers, as per EIL standard specifications, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1024 6 Fiber 1025 Supply of straight through jointing kit for Multi mode, multitube/unitube, jelly filled, Optical fiber cable with non metallic armour with following number of fibers, as per EIL standard specifications, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1026 6 Fiber 1027 Making of straight through jointing kit for Mono/Multi mode, multitube/unitube, jelly filled, Optical fiber cable with non metallic armour with following number of fibers, as per EIL standard specifications, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1028 6 Fiber 1029 END TERMINATIONS FOR COMMUNICATION/FIRE ALARM CABLES. 1030 Termination of following polyethylene insulated armoured jelly filled/ non filled cables including cutting, stripping of cable insulation, sealing of jacket including supply of termination kit, hardware, including all labour and materials, as per approved drawings, specification of this tender and directions of Engineer-in-Charge. 1031 For Non-Jelly filled cables of size .9 mm5 pair 1032 For Non-Jelly filled cables of size .9 mm2 pair 1033 For Non-Jelly filled cables of size .9 mm50 pair 1034 For Non-Jelly filled cables of size .63 mm20 pair 1035 For Non-Jelly filled cables of size 1.5 mm2 pair 1036 For Non-Jelly filled cables of size 1.5 mm²2 pair 1037 Supply ,Installation, testing and commissioning of Fiber Optic Patch panel (LIU) for following type & number of fiber for OFCs including all accessories for terminating, pigtails with Connectors, patch cords with connectors, Splicing sleeves and splice tray including all labour and materials as per approved drawings specifications of this tender and directions of engineer-in-Charge 1038 For 6 fiber Mono mode cable with LC pigtails and LC patch cords 1039 For 6 fiber Mono mode cable with SC pigtails and LC patch cords 1040 For 6 fiber Mono mode cable with ST pigtails and LC patch cords 1041 For 6 fiber Mono mode cable with LC pigtails and SC patch cords 1042 For 6 fiber Mono mode cable with LC pigtails and ST patch cords 1043 For 6 fiber Mono mode cable with SC pigtails and SC patch cords 1044 For 6 fiber Mono mode cable with SC pigtails and ST patch cords 1045 For 6 fiber Mono mode cable with ST pigtails and SC patch cords 1046 For 6 fiber Mono mode cable with ST pigtails and ST patch cords 1047 Termination of optical fiber cables for various systems including supply of all hardware, splice connectors, accessories, including all labour and materials as per approved drawings specifications of this tender and directions of engineer-in-Charge 1048 6 Fiber 1049 SUPPLY OF COMMUNICATION / FIRE ALALRM CABLE / CONDUITS / DUCTS 1050 Supply of communication, fire alarm & control paired cables of following sizes as per EIL standard specification No.6-51-0052, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1051 Jelly filled cables of size .9 mm20 pair 1052 Jelly filled cables of size .9 mm10 pair 1053 Non-Jelly filled cables of size .9 mm5 pair 1054 Non-Jelly filled cables of size .9 mm2 pair 1055 Non-Jelly filled cables of size 1.5 mm2 pair 1056 Non-Jelly filled cables of size .9 mm50 pair 1057 Non-Jelly filled cables of size .63 mm2 pair 1058 Supply of Mono mode, jelly filled, Optical fiber cable with non metallic armour with following number of cores & construction, as per EIL standard specifications, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1059 6 Fiber multitube construction 1060 Supply of Multi mode, jelly filled, Optical fiber cable with non metallic armour with following number of cores & construction, as per EIL standard specifications, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1061 6 Fiber multitube construction 1062 Supply of HDPE ducts for laying of optical fiber cables between various substations, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge 1063 HDPE duct with overall dia. Upto 60mm 1064 HDPE duct with overall dia. above 60mm 1065 CIVIL WORKS/M.S. CHEQUERED PLATE 1066 Making through and through cut outs in pockets of size 150 mm dia in the RCC floor/walls of trenches/buildings of thickness upto 200mm for facilitation cable entries using concrete cutting machines including all labour and materials as per approved drawings, specifications of this tender and directions of Engineer -in-charge 1067 Excavation and backfilling of trenches for cables and earth strip etc. , for a maximum depth of 1.5 m, shoring, shuttering and dewatering (if necessary) including consolidation and disposal of surplus earth up to a distance of 30 m, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. (Excavated trench dimensions shall be measured). 1068 Excavation and backfilling of trenches in all types of soil including rock. 1069 Excavation and backfilling of trenches in all types of soil except rock. 1070 Supply and laying of 40 mm size gravel in one layer of 100/150 mm thick including dressing of soil surface and laying the aggregate in uniform layer and density, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge ( Aggregate will be measured in boxes of size 1.5 m x 1.5 m x 0.5 m which shall be taken as 1 cubic metre, the boxes are to be furnished by the contractor free of cost for measuring purposes). 1071 40 mm size gravel. 1072 Supply and spreading of approved fine river sand/stone dust in cable trenches, including all labour and materials, specifications of this tender and directions of Engineer-in-Charge. 1073 Fine river sand. 1074 Supply and spreading of approved FLY ASH BRICKS - TYPE-5 of 75 mm thickness in cable trenches for cable protection, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. (Actual area of laid brick surfaces shall be measured). 1075 Bricks. 1076 Supply, fabrication and installation of 6 mm thick M.S. chequered plate for covering floor cut- outs/cable trenches etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1077 6 mm thick M.S. chequered plate. 1078 Making through and through cut outs in pockets of following shape and size in the RCC floor/ walls of trenches/ buildings of thickness above 200 mm and upto 400 mm for facilitating cable/ duct entries, using concrete cutting machines and making cut out good using plastering and painting including all material and labour as per approved drawings, specification of this tender and directions of Engineer-in-charge. 1079 Rectangular Cut Out of length 200 mmwidth 200 mm 1080 Circular Cut Out of diameter 150 mm 1081 LAN SYSTEMS 1082 Supply, installation, mounting, testing & commissioning of following Ethernet switches including performance warranty certification(for LAN) of 25 years through OEM, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-charge. 1083 Etherswitch Rack Type-I 1084 PAINTING & MARKING 1085 Letter painting and marking of all buses of switchboards, all incomers, bus couplers, outgoings with details of Tag No, feeder rating in KW/Amp, sending end source, in the front of the panels and bus bar, panel nos.etc. on the rear side of the panels for all switchboards, all other substation equipment viz.transformers, capacitors, neutral grounding resistors, VFD panels, other panels, etc for equipment housed in electrical substations including supply of all material such as stickers, enamel paints, stencil, etc including supply of all labour, materials as per the specification of this tender and directions of Engineer-in-Charge. 1086 Each alphabet/character above 2 inch and Upto 4 inch in height/length 1087 Each alphabet/character upto 2 inch in height/length 1088 Each alphabet/character above 4 inch and Upto 8 inch in height/length 1089 Each alphabet/character above 8 inch and Upto 12 inch in height/length 1090 Letter painting of tag nos., applicable circuit nos. for identification with red/black/white paint for all outdoor equipment in safe and hazardous areas viz.light fittings, control gear boxes, lighting/power panels, welding receptacles, convenience receptacles, local control stations, fire alarm manual call points, fire alarm detectors, motors,field call stations, loud speakers, etc. including supply of enamel paint, all hardware as required,supply of all labour, materials as per the specification of this tender and directions of Engineer-in-Charge. 1091 Each alphabet/character above 2 inch and Upto 4 inch in height/length 1092 Each alphabet/character upto 2 inch in height/length 1093 Each alphabet/character above 4 inch and Upto 8 inch in height/length 1094 Each alphabet/character above 8 inch and Upto 12 inch in height/length 1095 INSTRUMENTATION 1096 PRESSURE GAUGES AND ACCESSORIES (Incl. supply of Impulse pipe/Tubing material) 1097 Installation of Line mounted or Remote mounted or Local Gauge Board mounted Pressure gauge/ Pressure gauge with Pulsation Dampener/ Syphon/ Overrange Protector (direct/ surface mounted/ diaphragm seal type) inclusive of mounting of instrument, supply of piping and tubing materials such as valves, fittings, pipes, tubes, compression fittings, as per specification, supply and erection of supports, mounting on support, (if support required), laying of capillary on supports, fabrication and installation of manifolds/ impulse lines with supports as per standards indicated below, hydraulic testing and painting of supports but exclusive of Supply of Instrument, Gauge Board, Yoke, and Calibration. 1098 In Carbon Steel as per Standard 7-52-1103 1099 In Carbon Steel as per Standard 7-52-4079. 1100 DIFFERENTIAL PRESSURE GAUGES (Incl. supply of Impulse pipe/Tubing materials) 1101 Installation of Differential Pressure gauge with/ without pulsation dampner/Syphon/ overrange protector including one side capillary type)/ Diaphragm seal type Differential Pressure gauge, surface/ yoke mounted inclusive of mounting of instrument, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compression fittings as per specifications enclosed, supply and erection of supports, mounting on support, laying of capillary on supports, fabrication and installation of manifolds/ impulse lines with supports as per standards indicated below, hydraulic testing and painting of supports but exclusive of Supply of Instrument and Calibration 1102 In Carbon Steel as per Standard 7-52-4077. 1103 In Carbon Steel as per Standard 7-52-4078. 1104 PRESS.INSTRUMENTS (Incl. supply of Impulse pipe/Tubing material) 1105 Installation of Pressure Transmitters/ Pressure Switches (with or without Pulsation Dampener, Overrange Protector)/ Diaphragm seal type Pressure Transmitters/ Diaphragm seal type Pressure Switches including mounting on Yoke/ Surface, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compression fittings as per specifications enclosed, supply of supports for capillary, supply and erection of supports for impulse lines wherever required, fabrication and installation of manifolds/ impulse lines with supports as per Standard indicated below, laying of capillary on supports, hydraulic testing and painting of supports but exclusive of Supply of Instrument, all Electrical/ Pneumatic connections, Yoke and Calibration. 1106 In Carbon Steel as per Standard 7-52-1101 1107 In Carbon Steel as per Standard 7-52-1159 1108 In Carbon Steel as per Standard 7-52-1188 1109 In Carbon Steel as per Standard 7-52-1102 1110 In Carbon Steel as per Standard 7-52-1163 1111 In Stainless Steel as per Standard 7-52-1159 1112 DIFFERENTIAL PRESSURE INSTRUMENTS (Incl. supply of Impulse pipe/Tubing materials) 1113 Installation of Differential Pressure Transmitters (including one side capillary type)/ Differential Pressure Switch(including one side capillary type)/ Diaphragm seal type DP Transmitters/ Diaphragm seal type DP Switch including mounting on Yoke/ Surface, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compression fittings as per specifications enclosed, ,supply and erection of supports for impulse lines wherever required, fabrication and installation of manifolds/ impulse lines with supports as per Standard indicated below, supply and fabricating of supports for capillary, laying of capillary on supports, painting, installation of flushing connection, hydraulic testing of impulse lines as per standard indicated below but exclusive of Supply of Instrument, all Electrical/ Pneumatic connections, Yoke and Calibration. 1114 In Carbon Steel as per Standard 7-52-1140 1115 In Carbon Steel as per Standard 7-52-1192 1116 DIFFERENTIAL PRESSURE (FLOW) TRANSMITTERS (Incl. supply of Impulse pipe/Tubing material) 1117 Installation of Differential pressure(with or without integral manifold)/ Diaphragm Seal Type Differential Pressure flow instruments including Mounting on Yoke, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compressive fittings as per specifications enclosed,supply of supports for impulse lines/ manifolds/ capillary, fabrication and Installation of manifolds/ impulse lines with supports as per Standard indicated below, laying of capillary on supports, hydraulic testing and painting of supports but exclusive of Supply of Instruments, all Electrical/ Pneumatic connections, Yoke and Calibration. 1118 In Carbon Steel as per Standard 7-52-3489. 1119 In Carbon Steel as per Standard 7-52-3490. 1120 In Carbon Steel as per Standard 7-52-3491. 1121 In Stainless Steel as per Standard 7-52-3490. 1122 ULTRASONIC FLOWMETER 1123 Installation of Transmitters/ Preamplifiers for ultrasonic flowmeters on yoke/ instrument (if required) including Straight length spool piece with pressure and temperature compensation loop including laying and termination of interconnection cable supports for cables as required, painting of supports but exclusive of supply of instrument, yoke and calibration. 1124 Installation of Transmitters/ Preamplifiers for Ultrasonic Flowmeters 1125 DIFFERENTIAL PRESSURE (LEVEL) TRANSMITTERS (Incl. supply of Impulse pipe/Tubing material) 1126 Installation of DP type/ Diaphragm Seal DP type Level Instrument including mounting on Yoke, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compressive fittings, as per specifications enclosed, supply of supports for impulse line/ capillary/ manifold, fabrication of manifolds and erection wherever required, laying of capillary on supports, fabrication and installation of impulse lines with support as per Standard indicated below, hydraulic testing and painting of supports but exclusive of Supply of Instrument,all Electrical/ Pneumatic connections, Yoke and Calibration. 1127 In Carbon Steel as per Standard 7-52-1523. 1128 In Carbon Steel as per Standard 7-52-1524. 1129 LEVEL GAUGES (Incl. supply of Impulse pipe/Tubing material) 1130 Installation of Level Gauges on Vessel/ Piping/ Standpipes with minor modification wherever required, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compression fittings, as per specifications enclosed, fabrication of primary piping, fabrication and installation of drain valve/ vent valve assembly as per Standard indicated below, hydraulic testing of gauge, installation of illuminators/ non-frosting extension if required but exclusive of Supply of Gauges and Illuminators. 1131 In Carbon Steel as per Standard 7-52-1527 1132 SERVO TYPE TANK GAUGES 1133 Installation/ interconnection of Servo type Gauges with/ without Tank Farm Management (TFM) System components. Installation of Gauge, Isolation ball valve, Calibration chamber on flanged equipment nozzle, with or without still well, Junction boxes with barriers, power switch, all Electrical connections but exclusive of Supply of Instrument, still well and Calibration/ Setting of gauges. 1134 Servo Gauge Installation 1135 RADAR LEVEL INSTRUMENTS 1136 Installation of radar sensor and antenna, flanged type connection on equipment nozzle/ rail mounting with/without still well, but exclusive of supply of instruments. Installation of electronics units (total system for indication, transmission, marshalling etc. for one tank), including mounting on Yoke, supply of angle tray with supports, fabrication and erection of supports and laying of cable up to instrument/probe with clamps, termination of cables at both ends, but exclusive of supply of Instruments, supply of yokes and Calibration. 1137 Installation of Top Mounted Radar 1138 Installation of tank side indicator/electronic unit (total system for indication/ transmission/marshalling etc., as required for one tank) including mounting on yoke/support, fabrication and erection of supports, laying and termination of interconnecting cable up to instrument/ indicator with clamps, termination of cables at both ends, painting of supports but exclusive of supply of instruments, yoke, cables and calibration. 1139 Tank Side Indicator 1140 TEMPERATURE INSTRUMENTS 1141 Installation of Temperature Indicators/ Gauges (Filled system/ Bimetallic) RTD/ Thermocouple/ Temperature Switches/ Temperature transmitters with flanged thermowell inclusive of installation of machined/ built-up thermowells on the nozzle and installation of Instruments, Electrical/ Pneumatic connection but exclusive of Supply of Instruments/ Elements/ Thermowell, and Calibration. 1142 Temperature Indicator/ Gauges (Bimetallic Type) with thermowell on flanged wells 1143 TEMPERATURE TRANSMITTERS (REMOTE MOUNTED) 1144 Thermocouple/ RTD element with thermowell, along with Temperature Transmitter remote mounted. Installation of transmitter including mounting on yoke, fabrication and erection of supports with clamps and laying of extension/RTD cable upto thermocouple, termination of cables at both ends, painting of supports but exclusive of Supply of Instruments, Cable, Yoke and Calibration. 1145 Temperature transmitter and RTD. 1146 Temperature Transmitter and RTD with flanged well 1147 Multipoint temperature transmitter with Thermocouple / RTD 1148 MISCELLANEOUS ITEMS AND DEVICES 1149 Mounting of Miscellaneous instrument items as listed below on Yoke; fabrication and erection of Supports and including installation of instrument items,paintingofsupportsbutexclusiveofSupplyofInstrumentitems, Piping/ Tubing material / Calibration and supply and erection of Yoke support. 1150 ER probe assembly with accessories like flange, valve etc, if any, fixing of gaskets bolts/nuts wherever required and performing Positive Material Identification(PMI) using alloy analysers as per specification, drawings and directions of Engineer-in-Charge. 1151 Corrosion coupon assembly with accessories like flange, valve etc, if any, fixing of gaskets bolts/nuts wherever required and performing Positive Material Identification(PMI) using alloy analysers as per specification, drawings and directions of Engineer-in-Charge. 1152 Weather proof Push Button Station/ Selector Switches. 1153 Corrosion Transmitters 1154 CALIBRATION/ TESTING 1155 Cleaning, adjusting stroke/ positioner, stroke speed checking of Control and On-off (Shutdown) valves. Providing equipments, necessary test jig, Instrument Air, Nitrogen Cylinders, test reports, all consumable and loop testing. Excludes flow calibration 1156 Control Valves 1157 Self Actuated Pressure reducing valves 1158 Cleaning, set pressure tests of Pressure Relief and Thermal Relief Valves. Providing equipment, necessary test jig, Instrument Air, Nitrogen Cylinders, test reports, all consumable. Excludes flow calibration. 1159 Sizes upto 3/4 x 1 threaded 1160 Inlet Sizes upto 2 flanged, rating 150# to 2500# 1161 Cleaning, calibration of the instrumentslisted below including removal of instrumentfromreinstalledlocationslikepanels,enclosures,racks,field etc.,andfixingthembackinrespectiveplaces,providingequipments, necessarytestjig,InstrumentAir,NitrogenCylinders,testreports,all consumable, exceptforspecialimportedtestequipments for electronic instruments to be supplied by owner if available. 1162 Pressure gauges 1163 Pressure transmitters 1164 Differential Pressure Gauges 1165 Differential Pressure Transmitters for Flow, Level and D.P. 1166 Temperature gauges 1167 Temperature Transmitters 1168 Tank Level Instrument (Radar type) 1169 Servo Type Tank Gauges 1170 Electronic Local Indicator 1171 Cleaning, checking and functional tests for flowmeters. Providing equipments, necessary test jig, Instrument Air, test reports, all consumable, except for special imported test equipments for electronic instruments to be supplied by owner if available. Excludes flow calibration. 1172 Ultrasonic flowmeters 1173 LOOP CHECKING 1174 Loop checking (excluding calibration/ testing) of the instruments listed below including verifying the functional performance of all elements comprising the loop, thereby ensuring proper interconnections and operation, with all other specifications inline with clause 4.13 of Standard specification for Erection tender 6-52-0060. 1175 Pressure transmitters 1176 Differential Pressure Transmitters for Flow, Level and D.P. 1177 Temperature Transmitters 1178 Special Level Instruments/ Guided Wave / Ecclipse type Radar level instruments 1179 Tank Level Instruments (Radar type) 1180 Electronic Local Indicator 1181 Speed / Vibration Transmitter 1182 Push Button/Selector Switches/Lamps 1183 Control valve positioner 1184 Corrosion Transmitter 1185 Loop checking (excluding calibration/ testing) of the flowmeters listed below including verifying the functional performance of all elements comprising the loop, thereby ensuring proper interconnections and operation, with all other specifications inline with clause 4.13 of Standard specification for Erection tender 6-52-0060. 1186 Ultrasonic flowmeters 1187 SUPPLY ITEMS 1188 Supply of Instrument items as per specifications enclosed elsewhere in the Tender. 1189 24 Orifice plate as per Instrument data sheet no. B861-700-YF-DS-0001. 1190 2/300# Orifice plate & flange assembly as per Instrument data sheet no. B861-700-YF-DS-0001. 1191 3/300# Orifice plate & flange assembly as per Instrument data sheet no. B861-700-YF-DS-0001/B861-851-YF-DS-0001. 1192 4/300# Orifice plate & flange assembly as per Instrument data sheet no. B861-851-YF-DS-0001. 1193 Magnetic Level Gauge as per Instrument data sheet no. B861-701-YL-DS-2900. 1194 Breather valve as per Instrument data sheet no. B861-701-YB-DS-3200. 1195 Retractor Tool for ER probes system & Corrosion coupon system as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1196 Tubular ER Probe system (Tag No. 701-CP-1701) with ER probe assembly, corrosion transmitter (Tag No. 701-CT-1701), 1 working and 1 spare ER probes for each ER probe locations as per data sheet no. B861-701-YI-DS- 3001 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1197 Tubular ER Probe system (Tag No. 701-CP-1801) with ER probe assembly,corrosion transmitter (Tag No. 701-CT-1801), 1 working and 1 spare ER probes for each ER probe locations as per data sheet no. B861-701-YI-DS- 3002 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1198 Tubular ER Probe system (Tag No. 701-CP-1901) with ER probe assembly, corrosion transmitter (Tag No. 701-CT-1901), 1 working and 1 spare ER probes for each ER probe locations as per data sheet no. B861-701-YI-DS- 3003 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1199 Tubular ER Probe system (Tag No. 701-CP-2001) with ER probe assembly, corrosion transmitter (Tag No. 701-CT-2001), 1 working and 1 spare ER probes for each ER probe locations as per data sheet no. B861-701-YI-DS- 3004 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1200 Tubular ER Probe system (Tag No. 701-CP-2101) with ER probe assembly, corrosion transmitter (Tag No. 701-CT-2101), 1 working and 1 spare ER probes for each ER probe locations as per data sheet no. B861-701-YI-DS- 3005 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1201 Corrosion coupon system (Tag No. 701-CC-1701) with Corrosion Coupon Holder Assembly, 25 nos. of coupons for each corrosion coupon location as per data sheet no. B861-701-YI-DS- 3001 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1202 Corrosion coupon system(Tag No. 701-CC-1801) with Corrosion Coupon Holder Assembly, 25 nos. of coupons for each corrosion coupon locationas per data sheet no. B861-701-YI-DS- 3002 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1203 Corrosion coupon system(Tag No. 701-CC-1901) with Corrosion Coupon Holder Assembly, 25 nos. of coupons for each corrosion coupon location as per data sheet no. B861-701-YI-DS- 3003 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1204 Corrosion coupon system(Tag No. 701-CC-2001) with Corrosion Coupon Holder Assembly, 25 nos. of coupons for each corrosion coupon location as per data sheet no. B861-701-YI-DS- 3004 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1205 Corrosion coupon system(Tag No. 701-CC-2101) with Corrosion Coupon Holder Assembly, 25 nos. of coupons for each corrosion coupon location as per data sheet no. B861-701-YI-DS- 3005 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1206 24 V DC loop powered spare corrosion Transmitter. 1207 Type: Non-contact type Radar Level Instrument (Tag No. 700-LT-1601)as per data sheet no.B861-700-YL-DS-2000 , Smart Transmitter with integral display , Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply, Gauge Head: 6 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART / 1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1208 Type: Non-contact type Radar Level Instrument (Tag no. 700-LT-1602)as per data sheet no.B861-700-YL-DS-2001 , Smart Transmitter with integral display & local indicator, Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply,Gauge Head: 6 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART /1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1209 Type: Non-contact type Radar Level Instrument (Tag No. 701-LT-2201) as per data sheet no.B861-701-YL-DS-2000 , Smart Transmitter with integral display & local indicator, Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply, Gauge Head: 8 Flanged connection / Top mounted, Flange Material: SS316 , Accuracy: +/- 3mm, Output: 4-20 mA HART /1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1210 Type: Non-contact type Radar Level Instrument (Tag No. 701-LT-2203) as per data sheet no.B861-701-YL-DS-2001 , Smart Transmitter with integral display, Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply, Gauge Head: 6 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART /1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1211 Type: Non-contact type Radar Level Instrument (Tag No. 701-LT-2204) as per data sheet no.B861-701-YL-DS-2002 , Smart Transmitter with integral display & local indicator, Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply.Gauge Head: 6 Flanged connection / Top mounted , Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART /1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1212 Type: Non-contact type Radar Level Instrument (Tag No. 851-LT-5501) as per data sheet no.B861-851-YL-DS-2000 , Smart Transmitter with integral display , Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply, Gauge Head: 8 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART / 1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1213 Type: Non-contact type Radar Level Instrument (Tag No. 851-LT-5502) as per data sheet no.B861-851-YL-DS-2001 , Smart Transmitter with integral display & local indicator, Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply.Gauge Head: 8 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART /1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1214 Type: Servo Level Instrument (TagNo. 701-LT-2202) as per data sheet no.B861-701-YL-DS-2003 , Smart Transmitter with integral display , Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply, Gauge Head: 6 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART/ 1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1215 Signal cableXLPE insulatedFRLS 2 QUAD X1.5 mm2 as per data sheet no.B861-000-YS-DS-7006. 1216 2/300# Orifice plate & flange assembly as per Instrument data sheet no. B861-700-YF-DS-0002. 1217 Signal cableFR2 QUAD X1.5 mm2 as per data sheet no.B861-000-YS-DS-7009. 1218 Industrial grade 4 1/2 digit digital Multimeter including accessories like battery, connecting pin, carry bag. 1219 Industrial grade digital mA loop calibrator including accessories like battery, connecting pin, carry bag. 1220 Industrial grade Multifunction calibrator with low , high pressure pump including accessories like charger, connecting pin, carry bag. 1221 Universal hand-held HART communicators with accessories including charger, connecting pin, carry bag. 1222 Differential Pressure (Flow) Transmitter-HART as per data sheet no. B861-700-YI-DS-3150 & B861-851-YI-DS-3150. 1223 Differential Pressure (Flow) Transmitter-HART as per data sheet no. B861-700-YI-DS-3151. 1224 Differential Pressure Transmitter-HART as per data sheet no. B861-700-YI-DS-3200. 1225 Differential Pressure (Level) Transmitter-HART as per data sheet no. B861-701-YI-DS-3050. 1226 Pressure Transmitter-HART as per data sheet no. B861-700-YP-DS-3001,B861-700-YP-DS-3002, B861-700-YP-DS-3003 & B861-701-YP-DS-3001. 1227 Pressure Transmitter-HART as per data sheet no. B861-701-YP-DS-3002 & B861-851-YP-DS-3002. 1228 Pressure Transmitter-HART as per data sheet no. B861-701-YP-DS-3003 & B861-851-YP-DS-3001. 1229 Multipoint Temperature Elements - RTD with thermowell as per data sheet no. B861-701-YT-DS-4050. 1230 Temperature Elements - RTD with thermowell as per data sheet no. B861-700-YT-DS-4101, B861-701-YT-DS-4002, B861-851-YT-DS-4001. 1231 Temperature Transmitter-HART as per data sheet no. B861-700-YI-DS-3100, B861-701-YI-DS-3100, B861-701-YI-DS-3101, B861-701-YI-DS-3102 & B861-851-YI-DS-3100. 1232 Temperature Elements - RTD as per data sheet no. B861-701-YT-DS-4001. 1233 Signal cableFR 1PX1.5 mm2 as per data sheet no.B861-000-YS-DS-7008. 1234 Pressure Gauges as per data sheet no. B861-851-YP-DS-1100 & B861-700-YP-DS-1100, B861-701-YP-DS-1100. 1235 Temperature Gauges with thermowell as per data sheet no. B861-851-YT-DS-4100, B861-700-YT-DS-4105, B861-701-YT-DS-4100. 1236 Pressure Gauges as per data sheet no. B861-700-YP-DS-1101, B861-701-YP-DS-1101. 1237 Differential Pressure Gauges as per data sheet no. B861-700-YP-DS-1102, B861-701-YP-DS-1102. 1238 Temperature Gauges with thermowell as per data sheet no. B861-700-YT-DS-4104, B861-701-YT-DS-4101. 1239 Signal cableXLPE insulatedFRLS 12PX1.5 mm2 1240 Signal cableXLPE insulatedFRLS 1PX1.5 mm2 1241 Supply of Junction boxes of various types and specifications 1242 Junction Box, Weatherproof type for 12 Pair Cable 1243 Junction Box, Weatherproof type for 3 Way 1244 Supply of Cable glands ofvarioustypes and specifications 1245 Weatherproof double compression type Cable gland, SS 304 material with PVC shroud, 1/2 NPTM 1246 Weatherproof double compression type Cable gland, SS 304 material with PVC shroud, 1 1/2 NPTM 1247 Weatherproof double compression type Cable gland, SS 304 material with PVC shroud, 3/4 NPTM 1248 Supply of plugs for cable entries of varioustypes and specifications 1249 Plug ,weatherproof type, SS 304 material, 1/2 NPTM 1250 Plug ,weatherproof type, SS 304 material, 1 1/2 NPTM 1251 Plug ,weatherproof type, SS 304 material, 3/4 NPTM 1252 Supply of compression tube fittings in Stainless Steel of various types and specifications 1253 Male Connector: Material: SS-316 : Size: 1/2 NPTM X 1/2 OD 153 Bar 1254 Male Connector: Material: SS-316 : Size: 1/4 NPTM X 1/4 OD 153 Bar 1255 Male Connector: Material: SS-316 : Size: 1/2 NPTM X 1/4 OD 153 Bar 1256 SS 316 Ball Valve 1/2 TH 41 Bar. 1257 Tube Union: Material: SS-316 ; Size: 1/2 OD x 1/2 OD 153 Bar 1258 Tube Cap; Material: SS-316 ; Size : 1/2 OD 153 Bar 1259 6 Way Air Manifold SS316 1260 Supply of instrument tubes of different types and specifications 1261 SS316L tube 1/2 OD 153 Bar 1262 SS316L tube 1/4 OD 153 Bar 1263 Supply of pipe and pipe fittings 1264 SS316 Pipe 1 PL End, SCH. 40S 1265 10% of impulse piping / tubing material subject to minimum 1 number (1 meter for pipe / tube), whichever is higher, of each type, size, rating & material wise (such as valves, fittings, pipes, tubes, compression fittings as listed in the list of items of installation standard no. 7-52-3489, 7-52-3490, 7-52-3491, 7-52-1527, 7-52-1523, 7-52-1524, 7-52-4077, 7-52-4078, 7-52-1192, 7-52-1140, 7-52-1103, 7-52-4079 , 7-52-1101, 7-52-1102, 7-52-1159, 7-52-1188 & 7-52-1163) in the overall SOR quantity as per specification as a Mandatory spare. 1266 SS316 Nipple 1/2 TH x TH, SCH. 80S 1267 SS316 Nipple 1 TH x PL, SCH. 40S 1268 SS316 Nipple 1 PL x PL, SCH. 40S 1269 SS316 Equal Tee 1 SW, 3000# 1270 SS316 Elbow 1” SW, 3000# 1271 SS316 Cap 1/2” TH, 3000# 1272 SS316 Cap 1” TH, 3000# 1273 SS316 Coupling full 1” SW, 3000# 1274 SS316 Globe Valve 1 SW, body rating: 800#, end rating: 3000# 1275 JUNCTION BOX INSTALLATION 1276 Installation of weatherproof junction boxes including supply, fabrication and installation of supports, installation of junction boxes, supply of 14 SWG Copper wire (max. length 10 m per Junction Box), laying and connection, screwing plugs for unused entries and painting but exclusive of supply of junction boxes and glands/ fittings for cable size 12Px0.5/1.0/1.5/2.5 mm² Signal/Alarm/ Control. 1277 Installation of weatherproof three way junction boxes for Power including supply, fabrication and installation of supports, installation of junction boxes, supply of 14 SWG Copper wire (max. length 10 m per Junction Box), laying and connection, screwing plugs for unused entries and painting but exclusive of supply of junction boxes and glands/ fittings for cable size 2C x 2.5 mm² 1278 LAYING OF CABLES 1279 Laying of instrumentation cables for signal, alarm, shutdown, control and signal cable on ducts, main trays, perforated trays, angle trays, trenches (including opening of cable duct covers if requiredthrough IRCs {Instrument Road Crossings}) including clamping, glanding the cables, termination at both ends including shield/ drain/ communication wire, providing and fixing identifying tags and megger testing but exclusive of supply of cables and erection of ducts, main tray, perforated tray/ angle trays and preparation of cable trench. 1280 Signal / Alarm / Control Cables of cable sizes 1P x 1.5 / 2.5 mm² 1281 Signal/ Alarm/ Control Cables of cable sizes 24C /12P x 1.5/ 2.5mm² 1282 Laying of power cables on ducts, main trays, perforated trays, angle trays, trenches (including through IRCs) including opening of cable duct covers if required clamping, glanding the cables, termination at both ends including shield/ drain/ communication wire providing and fixing of identifying tags and megger testing but exclusive of supply of multi cables and erection of ducts, main tray, perforated tray/ angle tray and preparation of cable trench 1283 For cable size 2C x 2.5 mm² 1284 EARTHING 1285 Supply, laying and termination of both ends of earthing cables from earth grid pit to the DCS/ Local panels/ Barrier earth bus bars in trays/ conduits/ trenches as required. 1286 At both ends of earth grid/ Instruments of copper wire (12 AWG) in trays and conduits as required excluding earth-pit preparation and electrode installation. 1287 PIPING / TUBING / FABRICATION WORK 1288 Fabrication and erection of SS Air lines and fittings including supply/ fabrication/ erection of supports, installation of distribution, pneumatic testing and painting of supports but exclusive of supply of pipe and fittings as per standard 1289 For size 1 1290 Laying of Bare/ PVC covered copper tubes/ SS tubes on perforated trays including clamping, termination at both ends, providing identifying tags at both ends and Air testing, but exclusive of supply of copper/SS tubes, fitting and erection of perforated tray/ angle tray 1291 1/2 / 12 mm O.D . (for SS tubes) 1292 Erection of SS Air distribution manifold and fittingsincludingsupply/ fabrication/ erection of supports, pneumatic testing andpaintingofsupportsbutexclusiveofsupplyofSSAir distribution manifold and fittings 1293 Installation of 6-way Air Manifold (1/2) as per Standard 7-52-1905 1294 Tubing Hook-up of Control valves/ Pneumatic Transmitters etc. with air filter regulator / positioner / solenoid valves / Current to Pneumatic converters etc. as per Standards 1295 as per standard 7-52-3982. 1296 RADIOGRAPHY - CARBON STEEL WELD JOINTS 1297 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Pressure Gauges 1298 In Carbon Steel as per Standard 7-52-1103. 1299 In Carbon Steel as per Standard 7-52-4079. 1300 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Differrential Pressure Gauge 1301 In Carbon Steel as per standard 7-52-4077. 1302 In Carbon Steel as per standard 7-52-4078. 1303 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Pressure Instruments installations 1304 In Carbon Steel as per Standard 7-52-1101. 1305 In Carbon Steel as per Standard 7-52-1159. 1306 In Carbon Steel as per Standard 7-52-1188. 1307 In Carbon Steel as per Standard 7-52-1102. 1308 In Carbon Steel as per Standard 7-52-1163. 1309 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Differential Pressure Instruments 1310 In Carbon Steel as per Standard 7-52-1140. 1311 In Carbon Steel as per Standard 7-52-1192. 1312 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Differential Pressure (Flow) Instruments 1313 In Carbon Steel as per Standard 7-52-3489. 1314 In Carbon Steel as per Standard 7-52-3490. 1315 In Carbon Steel as per Standard 7-52-3491. 1316 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Differential Pressure (Level) Instruments 1317 In Carbon Steel as per Standard 7-52-1523. 1318 In Carbon Steel as per Standard7-52-1524. 1319 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Magnetic Level Gauges 1320 In Carbon Steel as per Standard 7-52-1527. 1321 RADIOGRAPHY - CS SPECIAL, ALLOY STEEL, SS 1322 Radiography conforming to the requirements of the Piping Class for all weld joints in Piping of Instrument air supply distribution, In Stainless Steel as per Standard 7-52-1905. 1323 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Pressure Instruments installations 1324 In Stainless Steel as per Standard 7-52-1159. 1325 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Differential Pressure (Flow) Instruments 1326 In Stainless Steel as per Standard 7-52-3490. 1327 Fire protection of instrument cable duct/trays 1328 Supply and erection of fire protection material for instrument cable ducts as per specification enclosed elsewhere with tender 1329 Run of Duct 600mm(W) X 300mm(H) 1330 Supply and erection of fire protection of cable trays as per specification enclosed elsewhere with tender 1331 Run of Tray 100mm (W) X 30mm (H) 1332 Run of Tray 60 mm (W) X 20mm (H) 1333 Run of Tray 150 mm (W) X 75 mm (H) 1334 Run of Tray 300 mm (W) X 75 mm (H) 1335 STRUCTURAL 1336 Supply, Fabrication and erection of Galvanised Iron duct and its supports as per standard. Duct configurations include Duct Equal Tee, Duct Expander Tee, Duct Reducer Tee, Duct Offset Bend, Duct with Reducer, Vertical Plane Tee, Vertical Plane Elbow, Duct Bridge (jumpover), Sleeves. 1337 Run of Duct 1000mm (W) X 400mm (H) 1338 Run of Duct 600mm (W) X 300mm (H) 1339 Run of Duct 800mm (W) X 300mm (H) 1340 Supply and erection of prefabricated FRP perforated trays with covers as per specifications enclosed elsewhere in tenderdocument and its support including tees, bends and elbows 1341 tray of 60 mm (W) X 20 mm (H) 1342 tray of 150 mm (W) X 75 mm (H) 1343 tray of 300 mm (W) X 75 mm (H) 1344 tray of 100 mm (W) X 30 mm (H) 1345 CANOPY FOR INSTRUMENTS AND JUNCTION BOXES 1346 Supply of Prefabricated FRP canopies along with mounting accessories for local instruments, Transmitters, Junction Box etc. for mounting on the stanchion and alignment as per standard 7-52-0105 1347 FRP Canopy (All sides closed) - Field Instruments 1348 FRP Canopy (All Side Closed) - Temperature Transmitter and Loop Powered Indicator 1349 FRP Canopy For Junction Box - Front Side Open 1350 FRP Canopy (All Side Closed) - Guided Wave , Mass Flow Meter 1351 FRP Canopy for RTD / Thermocouple 1352 Erection of Prefabricated FRP canopies for local instruments, Transmitters, Junction Box etc. on the stanchion and alignmentas per standard 7-52-0105 1353 FRP Canopy (All sides closed) - Field Instruments 1354 FRP Canopy (All Side Closed) - Temperature Transmitter and Loop Powered Indicator 1355 FRP Canopy For Junction Box - Front Side Open 1356 FRP Canopy for RTD / Thermocouple 1357 FRP Canopy (All Side Closed) - Radar Level Instruments 1358 GENERAL SITE WORK 1359 Supply of Yoke supports for transmitters/ preamplifiers (wherever applicable) including supply, fabrication and erection of instrument yoke of all types and painting of yoke supports but exclusive of mounting of Instrument on supports. 1360 2 Yoke supports as per standard 7-52-0101 1361 Erection of 2 Yoke supports/ stanchions for Instruments but excluding supply and fabrication of Yoke support. 1362 Erection of2 Yoke supports for instruments excluding supply of Yoke 1363 Supply, fabrication and installation of structural supports with MS channel/angle/plates etc. for supports ofmiscellaneous instruments/cabinets/panels including cutting, welding , bolting, rivetting, groutingincluding supply and installation of installation hardware like anchor bolts/nuts etc., painting of supports including supply of paints as per specification, including all labours and materials and completion of jobs in all aspects as per drawings/directions of Engineer-in-Chargenor paid). 1364 Structural steel ISMC 100 1365 Identification of instrument items wherever required including supply of approved colour of paint/ paints (Fluorescent), painting of tag number (approx 25-50 mm high) on instrument item like transmitter, switches, level gauges, control valves etc. as specified by Engineer-in-Charge. 1366 Identification of instrument items 1367 Supply, Fabrication & Installation of Concrete Pedestal (RCC) for supporting JB/Yoke but exclusive of supply of JB/Yoke as per specifications/drawing attached 1368 Size 500 mm x 500 mm x 600 mm 1369 SITE ACTIVITIES BY MECHANICAL CONTRACTOR 1370 Supply & wrapping of single layer PIR Insulation (Cold conservation type insulation ) with thickness of 50mm for 1/2 impulse lineconsist of insulation blocks fixed with adhesives, joint sealants, protected from moisture/ water ingress by vapour barrier, vapour stop and covered with a weather protection jacket after cleaning the impulse lines of dust, rust, grease in line withJob specification for Insulation of piping & equipment ( B861-000-06-43-IL-S001 ) attached in the tender. The wrapping of the insulation around impulse line shall cover it completely without leaving any gap. Scope of supply & wrapping by Contractor includes all material, tools, tackles & labour etc. to complete the work in all respects. 1371 Supply & wrapping of single layer PIR Insulation (Surface condensation type insulation ) with thickness of 25mm for 1/2 impulse lineconsist of insulation blocks fixed with adhesives, joint sealants, protected from moisture/ water ingress by vapour barrier, vapour stop and covered with a weather protection jacket after cleaning the impulse lines of dust, rust, grease in line withJob specification for Insulation of piping & equipment ( B861-000-06-43-IL-S001 ) attached in the tender. The wrapping of the insulation around impulse line shall cover it completely without leaving any gap. Scope of supply & wrapping by Contractor includes all material, tools, tackles & labour etc. to complete the work in all respects. 1372 Transportation of all types of valves (Including Control Valves, Special Control Valves, Motor Operated Valves, PRDS, Control valves, On-Off/Shutdown valves, Self actuating valves) from Owners storage points to contractors stores/worksite and installation of valvesfor all rating including assembly of valves accessories like air bottles etc, if any, fixing of gaskets bolts/nuts wherever required and performing Positive Material Identification(PMI) using alloy analysers as per specification, drawings and directions of Engineer-in-Charge. 1373 Inlet Valve size - 12 , Rating - 300# 1374 Inlet Valve size - 1 , Rating - 300# 1375 Inlet Valve size - 1 1/2 , Rating - 300# 1376 Inlet Valve size - 3 , Rating - 300# 1377 Transportation of all types of Safety Valves, Pilot Operated Safety Valves from owners storage point to contractors store/worksite and installation of valves for all ratings including assembly of valves, accessories if any, at alllocations and fixing of gaskets, bolts/nuts wherever required as per drawings, specifications and as per the directions of engineer-in-charge. 1378 Inlet size - 1 , Rating - 150# 1379 Inlet size - 2 , Rating - 150# 1380 Inlet size - 4 , Rating - 150# 1381 Inlet size - 3/4 , Rating - NPT 1382 Impulse line painting (uninsulated) as per painting specification for project 1383 Instrumentation impulse line of size 1/2 for temp. (-)14 to 80 degC 1384 Impulse line painting (insulated) as per EIL painting specification for project. 1385 Impulse line size of 1/2 with material Carbon Steel for temp. (-)45 to 125 degC 1386 ENVIRONMENT 1387 Condensate Water Treatment Plant 1388 CONDENSATE WATER TREATMENT PLANT, WITH COMPLETE ACCESSORIES & AUXILLARIES (As per Document no. B861-000-17-42-SS-1001): The scope of work shall include design, engineering, procurement, fabrication, supply, transport, handling, storage at site, erection, civil, electrical, piping, painting, mechanical and instrumentation works, testing, pre-commissioning, commissioning, trial run and guarantee of condensate water treatment system and handing over of the same to the Owner. 1389 EQUIPMENT - PACKAGE 1390 Design, engineering, procurement of raw materials and bought out components, manufacture, assembly, inspection, testing, painting (both primer and finish coat) , erection, testing &commissioning of following Basket Strainers along with associated equipment/items complete in all respect for efficient & satisfactory operation as per enclosed Scope of Work (Doc no. B861-000-80-42-SOW-3001) & Process data sheets. 1391 BASKET STRAINERS, Tag Nos. 701-STR-1701/1702 1392 BASKET STRAINERS, Tag Nos. 701-STR-1801/1802 1393 BASKET STRAINERS, Tag Nos. 701-STR-1901/1902 1394 BASKET STRAINERS, Tag Nos. 701-STR-2001/2002 1395 BASKET STRAINERS, Tag Nos. 701-STR-2101/2102 1396 Supply and Installation of Wall mounted Split Air Conditioners for Store Officer cabin : Supply of single phase inverter controlled Split Air Conditioner with compatible stabilizer (copper winding) complete with all accessories and fittings, including supply of first fill of refrigerants (non-CFC and eco-friendly), remote control, transportation from vendors works to site, unloading at site, handling, transportation to contractors store and from contractors store to work site, storage at site, assembly at site, installation and other field works including civil-structural works complete in all respect, testing, painting, insulation, commissioning, handing over to client. Split unit shall have wall mounted indoor unit and outside located air cooled condenser (outdoor unit) with insulated refrigerant piping (considering approx 10 m length between indoor and outdoor unit), controls and accessories, electrical and civil works(e.g. civil work related to concealing of refrigerant piping, drain piping to the nearest drain, cabling (considering approx 10 m length between indoor and outdoor unit) of AC units) as required including the structural steel framework, pedestal/bracket to mount the indoor and outdoor units, supports & clamps for refrigerant piping/cables, stabilizer, hold down nuts & bolts, spares for commissioning and start up etc. as per the enclosed Job Specification and other documents referred therein and instruction of engineer-in-charge for each equipment including accessories. 1397 Inverter Type Split Air Conditioner of capacity 1.5 TR having star rating 5 (BEE 5 star rating or equivalent) 1398 EOT CRANE (SAFE AREA APPLICATION) FOR MATERIAL STORE/ WORKSHOP BUILDING :Radio Remote Control(1 Working+ 1 Stand by) Operated-Design, engineering, manufacture, procurement of raw materials and bought out components, supply, fabrication, assembly, shop painting (primer + finish coat), inspection, testing (at manufacturers shop), packing and supply of double girder type EOT Crane including supply of all commissioning spares, special tools and tackles as applicable, mandatory spares, first fill of lubricant, consumables,erection material & documentation, transportation from Vendors works to designated storage site, handling, loading, unloading and storage, complete site works including transportation from storage site to work site, storage & handling at work site, assembly at site, erection installation, testing, touch-up painting, pre commissioning, commissioning, performance guarantee test run including arrangement of test loads, completing thework in all respects and handling over to Client, as per drawing, specifications, scope of work and instructions of engineer in charge and other attachment included in Tender for following EOT Crane.NOTE 1: Span or/and travel length of crane may undergo minor changes of ±0.5 meter during detailed engineering, for which no price & time implication shall be entertained.NOTE 2: Height of lift may undergo minor changes by ±0.5 meter during detailed engineering, for which no price & time implication shall be entertained.NOTE-3: Contractor shall arrange/bring adequate certified test loads during testing at EOT crane location. To and Fro transportation of test loads with cage (including loading, handling, unloading etc.), including taking back of test load after successful performance test from worksite and supply of manpower shall be in scope of Contractor). 1399 1 No. Double Girder E.O.T Crane with Main hook SWL (Safe Working Load) 15 MT , Auxillary hook SWL 3 MT , Span -12.7 m, Long Travel - 30 m , Height of lift - 8 m, M5 duty along with rails, fixtures and other accessories.(Refer Scope of Work , Job Specification & Electrical specifications ) enclosed elsewhere with this tender document). 1400 UNIT RATES FOR E.O.T CRANE FOR ADDITION/DELETION PURPOSE 1401 Unit Rate (ADDITION / DELETION) for ±0.5m in HEIGHT OF LIFT (over & above 0.5 m from specified data) 1402 Unit Rate (ADDITION / DELETION) for ±0.5m in SPAN (over & above 0.5 m from specified data). 1403 Unit Rate (ADDITION / DELETION) for ±0.5m in LONG TRAVEL (over & above 0.5 m from specified data) including rail fixtures. 1404 EQUIPMENT - ROTATING 1405 Handling and transportation of Rotating Equipment & miscellaneous items of equipment package from Owners storage points to work site / contractors stores, assembly of sub-assemblies, field assembly (as applicable) placing the equipment on foundations,(including some amount of cutting, welding & field joints wherever required), levelling, aligning, fixation of foundation bolts, providing (including supply) packing / shim plates (as applicable), including chipping & dressing of foundations, grouting (including supply and application of grout material, equipment base frame filling as per vendor recommendation with specified grout), cleaning and flushing, draining and drying, purging of lines, and providing manpower and tools / equipmentforNDT, testing, carrying out trial and start-up runs and testing under supervision of manufactures / customer personnel, rectifying defects (if any), insulation (as applicable),precommissioning and commissioning (as applicable) and completing the work in all respects as per drawings, job specifications / scope of work and instructions of Engineer-in-charge for each equipment including drivers and accessories, as listed below.NOTE: Scope also includes erection, fabrication, insulation (as applicable), welding & field joints wherever required, installation & NDT of vendor supplied prefabricated spools / commercial length between various skids of an equipment package (payable at the rate provided against piping SOR items). 1406 Pump Packages (all types) with drivers, auxiliaries and accessories. 1407 All Types of Pumps (Electric Motor Driven) along with driver, auxiliaries and accessories (Single Skid). 1408 Chemical Dosing Packages 1409 Skid mounted chemical dosing packages along with all auxiliaries and accessories. 1410 Procurement of Rotating Equipment Packages by Contractor.Engineering and Procurement of Rotating Equipment, handling and transportation of Rotating Equipment & miscellaneous items of equipment package from Owners storage points to work site / contractors stores, assembly of sub-assemblies, field assembly (as applicable) placing the equipment on foundations,(including some amount of cutting, welding & field joints wherever required), levelling, aligning, fixation of foundation bolts, providing (including supply) packing / shim plates (as applicable), including chipping & dressing of foundations, grouting (including supply and application of grout material, equipment base frame filling as per vendor recommendation with specified grout), cleaning and flushing, draining and drying, purging of lines, and providing manpower and tools / equipmentforNDT, testing, carrying out trial and start-up runs and testing under supervision of manufactures / customer personnel, rectifying defects (if any), insulation (as applicable),precommissioning and commissioning (as applicable) and completing the work in all respects as per drawings, job specifications / scope of work and instructions of Engineer-in-charge for each equipment including drivers and accessories, as listed below.NOTE: Scope also includes erection, fabrication, insulation (as applicable), welding & field joints wherever required, installation & NDT of vendor supplied prefabricated spools / commercial length between various skids of an equipment package (payable at the rate provided against piping SOR items). 1411 Diesel Engine based Electric Generator Set Packages with auxiliaries and accessories. 1412 Equipment Tag No. 701-DG-001 as per Document No. B861-000-80-42-SOW-3001 1413 EQUIPMENT - STATIC 1414 STORAGE TANKS 1415 PLATE WORK 1416 Plate work for Fixed Roof Tanks (Cone and Dome roof tanks) and covered Floating Roof tanks except Floating Roof:Procurement of all plates as per specifications, transportation to work site, fabrication and erection of shell, bottom (Sketch plates and annular plates including backing strips), cone roof, Dome roof, compression ring/knuckle plate, plate fabricated wind girders, wind girder opening, bearing plates for pipe supports, datum plates, shell manhole- necks, bolting and cover flanges for shell-man-holes, reinforcement pads for shell manholes, nozzle reinforcing pads, roof manhole-necks, bolting and cover flanges for roof manholes, reinforcing pads for Roof manholes, clean-out door assembly (including davit assembly), gusset- support for wind girders, Sump for drain nozzle, pads for all appurtenances and attachments, fabrication and installation of all items as per drawing, conducting tests such as vacuum test, MP/DP test, pneumatic test, oil penetrant examination, Grouting work (including the supply of grouting material, as required for the tanks installed on ring wall foundation) underneath the Annular/ bottom plateas per the specifications attached, tank hydrotest, etc. for shell, bottom and roof as specified, radiography including supply of films, all heat treatment specified in drawings/ specifications/ codes, preparation of drawings as per specifications, standards and relevant codes and getting the same reviewed by Owner/EIL, providing all temporary structures, clamps, wedges, including arrangement of all materials, consumables, labour, equipment, machinery, tools, tackles etc. to complete the work in all respects as per drawings, specifications, standards, codes, scope of work, scope of supply and instructions of Engineer- in-Charge.All bolting, gaskets wherever required as per scope of supply and scope of work shall be supplied and installed by Contractor. Spares 10% bolting (min. 2 nos.) and 200% spare gaskets shall be included in Contractors scope. Any other (Commissioning etc.) spares as mentioned in tender specifications shall be also be included in Contractors scope.Quoted price shall be inclusive of supply of all bolts, nuts, gaskets including spares. 1417 IS 2062 Gr. E250 (A, BR, B0, C) 1418 SA 516 Gr. 60/ 70 1419 STRUCTURAL/PIPES 1420 STRUCTURAL/ PLATE WORK :Supply, fabrication, erection, inspection and testing of steel structure for cone roof/ dome roof supporting structure including curb angle, spiral stairway, cage ladder, handrail, top and intermediate platform, grating for stairway steps and platform, rolling ladder including track for floating roof, anchor chairs,name plates, earthing connections, ladder rungs for ladders in covered roof tanks, wind girder fabricated from rolled section, wind girder bracings/ support, external structural supports, supports for shell extension for foam nozzles in case of floating roof tanks, stiffeners for shell extension plate of stairway, ventilation slots and over flow slots for covered floating roof tank including SS wire mesh, preparation of drawings, getting the same reviewed/ approved by owner/ EIL, arrangement of all materials, consumables, labour, equipment/ machinery, tools and tackles required to complete the work as per drawings, specifications, standards, codes, scope of work, scope of supply and instructions of Engineer- in-Charge. All materials to be supplied by Contractor. 1421 Roof structure as per Standard/Drg. 1422 SA 36 1423 IS 2062 1424 SA 516 Gr.60/70 1425 STILL WELLS/ DIP PIPES :Supply, fabrication, erection, inspection and testing ofstill well for gauge hatch, still well for level transmitter/ level switches, still well for temperature element including flanges on all still wells, dip pipes (process / instrumentation), pipe fittings, drilling of holes in still well/ dip pipes, arrangement of all materials, consumables, labour to complete the work as per drawings, specifications, standards, codes, scope of work, scope of supply and instructions of Engineer- in-Charge. All materials to be supplied by Contractor. 1426 SA 333 GR6 1427 SA 106 Gr. B 1428 STRUCTURAL PIPES (CS GALVANISED):Supply, fabrication, erection, inspection and testing of pipe specification for pipe handrails (CS and galvanised), arrangement of all materials, consumables, labour to complete the work as per drawings, specifications, standards, codes, scope of work, scope of supply and instructions of Engineer- in-Charge. All materials to be supplied by Contractor. 1429 PIPES(CS GALVANIZED) 1430 APPURTENANCES 1431 Supply, fabrication, installation, welding, radiography, heat treatment, inspection and testing as required for the following nozzles (reinforcing pads covered under plate work) pipe, nozzle flanges and blind / companion/matching flanges (including davit/ hinge assembly for Man way) wherever shown on drawings and standards along with gaskets and boltings including supply of mandatory spares, conducting air pressure test for reinforcing pads, preparation of drawings, getting the same reviewed by Owner/EIL, arrangement of all materials, consumables, labour to complete the work as per drawings, specifications , standards, codes, scope of work, scope of supply and instructions of Engineer-in- Charge. All internal bolting shall be SS 304 as a minimum and contractor shall include the same in his scope of supply and shall be included in nozzleassembly quoted price. Spare gaskets ( 2 nos.) and 10% spare bolting (minimum 2 nos.) shall be included in Contractors scope of supply and shall be included in nozzle assembly quoted price. 1432 Roof Nozzle 150 Class WNRF Type 1.5 InchSize SA 350 LF2 Material 1433 Roof Nozzle 150 Class WNRF Type 2 InchSize SA 105 Material 1434 Roof Nozzle 150 Class WNRF Type 8 InchSize SA 105 Material 1435 Shell Nozzle 150 Class WNRF Type 2 InchSize SA 105 Material 1436 Shell Nozzle 150 Class WNRF Type 4 InchSize SA 105 Material 1437 Shell Nozzle 150 Class WNRF Type 6 InchSize SA 105 Material 1438 Roof Nozzle 150 Class WNRF Type 2 InchSize SA 350 LF2 Material 1439 Roof Nozzle 150 Class WNRF Type 3 InchSize SA 350 LF2 Material 1440 Roof Nozzle 300 Class WNRF Type 3 InchSize SA 350 LF2 Material 1441 Roof Nozzle 150 Class WNRF Type 6 InchSize SA 350 LF2 Material 1442 Roof Nozzle 150 Class WNRF Type 8 InchSize SA 350 LF2 Material 1443 Shell Nozzle 150 Class WNRF Type 2 InchSize SA 350 LF2 Material 1444 Shell Nozzle 150 Class WNRF Type 3 InchSize SA 350 LF2 Material 1445 GOOSE NECK VENT WITH WIRE MESH:supply of materials,fabrication, installation,welding, radiography, heat treatment, inspection and testing as required for the (reinforcement pads covered under Plate work) goose neck vent with wire mesh (SS 304 as minimum) for the following vent materials. 1446 Size 2 InchMaterial SA 106 Gr. B 1447 INSTRUMENTS 1448 Transportation of following instruments from Owner/Storage yard/stores and installation of the same in position as per instructions of Engineer-in-Charge/Supplier. (Contractor shall take care so that no damage occurs while handling these instruments). 1449 Pressure Transmitter Instrument 1450 Level Transmitter Instrument 1451 Breather Valve Instrument 1452 Emergency Vent Instrument 1453 Temperature Gauge Instrument 1454 CALIBRATIONCarrying out calibration of tanks including supply of strapping tapes, scaffolding wherever required, arranging the visit of competent authority, all accessories, labour, preparation and submission of calibration charts duly approved by Competent authority etc. and complete the work in all respect as per Codes, specifications, standards and instructions of Engineer-in-Charge 1455 Diameter (Meters) : upto 10 Height (Meters) : upto10 1456 Diameter (Meters) : > 10 to 25 Height (Meters) : > 10 1457 DESIGN, SUPPLY & INSTALLATION OF EMERGENCY VENT (Lumpsum)Design, engineering, manufacture, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturers works, packing, delivery, documentation as per the enclosed M/s EIL specification and installation of Emergency Vent etc. to the satisfaction of the Engineer- in Charge. 1458 DESIGN, SUPPLY & INSTALLATION OF BREATHER VALVE (Lumpsum):Design, engineering, manufacture, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturers works, packing, delivery, documentation as per the enclosed EIL specification and installation of breather valves etc. to the satisfaction of the Engineer-in-charge. 1459 Gauge Hatch with Cover:Supply & installation of Gauge Hatch with Cover for the tankages mentioned in the data sheets/ drawings/ specifications as per the Specifications & Standards attached with the tender. Arrangement of machinery, tools & tackles, labour etc. to accomplish the installation of the same shall also be in the scope of Contractor. The following Gauge Hatch with cover are required. 1460 Material: CS 1461 PAINTING OF TANKS 1462 PAINTING FOR CARBON STEEL AND LOW ALLOY STEEL TANKS 1463 ExternalSurfaces (except underside of bottom plate): Surfacepreparation to SSPC-SP-10,applicationofprimerandpaint onallexternalsurfacesoftanksincluding insulatedtanks i.e.externalshell,windgirders,appurtenances,rooftops including top sideoffloatingroofofopentanksaswellascovered floatingrooftanks, external roof supporting structure,associatedstructuralsteelworks,ladders,walkways, platforms,handrails,spiralstairway,rollingladderandtrack, internal surface of shell above maximum liquid level exposed to atmosphere for open top or floating roof tanks asper painting system defined below and otherrequirementsasspecifiedinrespectiveEngg.datasheets, stencillingtankno., capacity, name of storedproduct,paintingEmblem aspertheattachedsample,includingsupply of metallicandnon-metallic materials,primerandpaintofapprovedquality,providingscaffolding, labour,equipment,consumables,etc.tocompletetheworkinall respect asperapplicable standard specifications,standardsattached elsewhere in the tender document andinstructionsofEngineer- in-Charge. All materials shall be supplied by Contractor. 1464 Design Temperature Range: (-) 14 °CTo 80 °CPrimer: 1coat of F-9 @ 65-75μ DFT/coat + 1coat of P-6 @ 40μ DFT/ coat Finish Paint: 2 coats of F-6B @ 100μ DFT /coat + 1 coat of F-2 @ 40μ DFT/ coat Remarks: Total DFT in Microns (minimum) = 345-355 1465 ExternalSurfaces (underside of bottom plate): Surfacepreparation to SSPC-SP-10,applicationofprimerandpaint onunderside of bottom plate (soil side) asper painting system defined below and otherrequirementsasspecifiedinrespectiveEngg.datasheets includingsupplyofmetallicandnon-metallic materials,primerandpaintofapprovedquality,labour,equipment,consumables,etc.tocompletetheworkinall respect,asperapplicable standard specifications,standardsattached elsewhere in the tender document andinstructionsofEngineer- in-Charge. All materials shall be supplied by Contractor. 1466 Design Temperature range (-) 14°C to 80°C, Primer : 1 coat of F-9@ 65-75µ DFT/coat,Finish Paint : 3 coats of F-7 @ 100µ DFT /coat. 1467 Design Temperature Range: -29 °CTo 400 °CPrimer: 1 coat of F-16 @125 micron Finish Paint: 1 coat of F-16 @125 micron Remarks: total DFT : 250-300 micron 1468 InternalSurfaces:Surfacepreparation to SSPC-SP-10,applicationofprimerandpaint oninternalsurfaceofbottomplate,shell full height,internal surfacesofcone/dome roof,roofstructure,oil side surfacesofpontoons & deck platesandoil side surfaces of doubledecks,internalladder,structuralsteel, internalsupportandinternalaccessories(exceptheatingcoil)asper painting system defined below and requirementsasgiven in the respective engg.datasheets. Supply of metallic and non-metallic materials, labour, primer andpaint of approved quality, equipment, consumables,etc. to complete the work in allrespect, as per applicable specifications, standardsattached elsewhere in the tender document and instructions of Engineer- in-Charge. All materials shall be supplied by Contractor. 1469 Design Temperature Range: -14 °CTo 60 °CPrimer: 1 Coat of F-6A@100 µ DFT/coat Finish Paint 2 Coats of F-6A@ 100µ DFT/Coat(2x100=200) Remarks: - 1470 Design Temperature Range: - °CTo - °CPrimer: - Finish Paint 3 coats of vinylchloride co- polymer @ 75µ/Coat; (3x75=225) Remarks: - 1471 EQUIPMENT ERECTION 1472 TOUCH-UP PAINT APPLICATION (UNINSULATED EQUIPMENT) FOR CS VESSEL 1473 Application of field primers and finish paint(Supply by Others) on C.S vessels, PHE and other equipment, including rubdown and touch up of shop primer (primer as per applicable specification) wherever required as per attached specification, providing scaffolding for all heights, labour, material, tools and tackles, consumables, supervision etc. to complete the work in all respect as per specifications, drawings, equipment details for painting and direction of Engineer in-Charge for all type of uninsulated equipment. The surface area is as per respective temperature ranges given in applicable specification. Note: Surface preparation, primer and finish paint already carried out by equipment supplier. 1474 EQUIPMENT ERECTION:Transportation of reactors, columns, vessels, silencers, heat exchangers (shell and tube, plate fin, plate) and electric heater etc. from owners storage point to work site, assembly of parts, subassemblies, erection at all elevations, aligning, verticality checking, grouting, tightening of foundation bolts, welding of washer on anchor chairs, erection of wooden pillow for cold equipments, stacking of multi-tier exchanger(which are stored in unstacked condition), arranging hooks for test ring/ test flanges in heat exchangers, installation of demister, internal gratings, distributor, pipe davit, installation of mixer/agitator,cleaning and flushing by water, draining, drying by compressed air, arranging all tools, tackles, machinery, consumables, transportation equipment, erection equipment, instruments, labour, ancillary, etc. to complete the work in all respects as per drawings, equipment detail, specifications and instructions of the Engineer-in-Charge. 1475 Equipment weighing less than 30 MT but 10 MT and above 1476 TOUCH-UP PAINT APPLICATION (INSULATED EQUIPMENT) FOR CS VESSEL 1477 Application of field primers and finish paint(Supply by Others) on C.S vessels, PHE and other equipment, including rubdown and touch up of shop primer (primer as per applicable specification) wherever required, as per attached specification, providing scaffolding for all heights, labour, materials, tools and tackles, consumables and supervision etc. to complete the work in all respect as per specifications, drawings, equipment details for painting and direction of Engineer in-Charge. The surface area is as per respective temperature ranges given in applicable specification. Note: Surface preparation, primer and finish paint shall be provided by equipment supplier. 1478 EQUIPMENT UNLOADING: Unloading of Equipment from trailer at designated receiving point, Transportation of the same and handling over to owner at designated storage point for the following as per drawings, equipment detail, specifications and instructions of the Engineer-in-Charge. 1479 Equipment weighing less than 50 MT but 30 MT and Above 1480 Equipment weighing less than 30 MT but 10 MT and above 1481 LETTERING AND STENCILING:Surface preparation, supply and application of primer and paint on insulated and uninsulated equipment for lettering, stenciling on vessels, columns, drums, for the purposes of identification (Equipment Name, Equipment Number & Service Description) as per applicable painting specification enclosed elsewhere in the tender document, arranging scaffolding for all heights, labour, materials, tools, tackles, supervision etc. to complete the work as per specifications and instructions of Engineer-in- Charge. 1482 ERECTION OF DRESSED-UP EQUIPMENT:Transportation of columns and vessels from owners storage point to work site, dressing up of the column/vessel by contractor , assembly of parts, subassemblies, erection at all elevations, aligning, verticality checking, grouting, tightening of foundation bolts, welding of washer on anchor chairs,arranging all tools, tackles, machinery, consumables,erection of completely dressed-up equipment, & arranging allinstruments, labour, ancillary, etc to complete the work in all respects as per drawings, equipment detail, specifications and instructions of the Engineer-in-Charge.Dressing up of column(As applicable as per the requirement of the tender): Supply/Application/installation of insulation, installation of ladders and platforms, installation of piping spool and support (wherever applicable), installation of demister, internal gratings, distributor, pipe davit etc on the Column/Vessel, cleaning and flushing by water, draining, drying by compressed air etc to complete the job in all respects as per the requirements of the specifications & standards attached else where in the tender. 1483 Equipment(Dressed-up) weighing less than 50 MT but 30 MT and Above 1484 ERECTION OF BURIED EQUIPMENT : Transportation of vessels from Owners storage point to worksite, repair/ touch up of finish paint, arrangement of all accessories, equipments, labour etc., placing/erection of vessel in trenches/pits including assembly of parts, subassemblies, aligning, verticality checking, grouting, tightening of foundation bolts,arranging all tools, tackles, machinery, consumables etc to complete the work in all respects as per drawings, equipment detail, specifications and instructions of the Engineer-in-Charge. 1485 Equipment weighing less than 30 MT but 10 MT and Above 1486 WELDING & NDT OF CUT NOZZLES / SUMP / BOOT OF BURRIED VESSELS:Assembly of cut nozzles/Sump/Boot(as shown in Respective Engg. Data Sheet), vertically checking, alignment, Welding of cut nozzles , NDT such as 100% radiography ,UT , surface preparation of the weld seam portion, application of primer, painting, arranging all tools and tackles, machinery. Consumables, transportation/handling of equipment, labour etc to complete the work in all respects as per drawings & instruction of Engineer-in charge. 1487 MOC : Carbon Steel ,Nozzle size : 2 1488 MOC : Carbon Steel ,Nozzle size : 3 1489 MOC : Carbon Steel ,Nozzle size : 6 1490 MOC : Carbon Steel ,Nozzle size : 8 1491 MOC : Carbon Steel ,Nozzle size : 20 1492 MOC : Carbon Steel ,Nozzle size : 24 1493 EQUIPMENT INSULATION 1494 COLD INSULATION: Providing cold insulation including supply of all insulating andanciliarymaterial,protectivecovering,consumablesand othernecessarymaterials,testingofthematerialasrequiredincluding transportationofthematerialstoworksites,applyinginsulationon surfacesasspecified,includingallpreparatoryworksthereon,allbinding, tying,lacing,stitchingand/orotherwisesecuring,providingvapour barrier,finishingwithplain/corrugatedsheetcladdingorasspecified, providingbolts,rivets,providing vapour stop etc.arranging necessaryscaffolding,alltoolsand tackles,equipment,apparatusetc.labourandsupervisionandcompleting theworkinallrespectatallheightsasperdrawings,specificationsand instructionsofEngineer-in-Charge. 1495 Shells of vertical vessels, columns, exchangers, reactors, silencers etc.Surface material:CS/AS. Insulation type:Ic (Polyurethane foam). Service: Other than LNG. 1496 Insulation Thickness: 50mm 1497 Shells and heads of horizontal vessels, columns, reactors, exchangers, silencers etc and heads of above mentioned vertical equipments. Surface material: CS/AS. Insulation type:Ic (Polyurethane foam). Service: Other than LNG. 1498 Insulation Thickness: 50mm 1499 STRUCTURAL 1500 EARTH WORK (REFER SPECIFICATION NO. 6-68-0003) 1501 Earthwork excavation in soil 1502 Earth work in EXCAVATION below ground level for all kinds of works in ALL TYPES OF SOILS EXCEPT SOFT ROCK AND HARD ROCK as classified in specification for a depth upto 1.5m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting. 1503 Earth work in EXCAVATION below ground level for all kinds of works in ALL TYPES OF SOILS EXCEPT SOFT ROCK AND HARD ROCK as classified in specification for a depth beyond 1.5m and upto and inclusive of 3.0m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting. 1504 Earth work in EXCAVATION below ground level for all kinds of works in ALL TYPES OF SOILS EXCEPT SOFT ROCK AND HARD ROCK as classified in specification for a depth beyond 3.0m and upto & inclusive of 4.5m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting. 1505 Earth work in EXCAVATION below ground level for all kinds of works in ALL TYPES OF SOILS EXCEPT SOFT ROCK AND HARD ROCK as classified in specification for a depth beyond 4.5m and upto & inclusive of 6.0m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting. 1506 SHORING AND STRUTTING 1507 Providing and installing approved type of SHORING AND STRUTTING by open timbering method for all depths to retain earth including dismantling and removal of the same etc. from site after completion of work etc. all complete as directed. 1508 Providing and installing approved type of SHORING AND STRUTTING by close timbering method for all depths to retain earth including dismantling and removal of the same etc. from site after completion of work etc. all complete as directed. 1509 Backfilling after execution of work 1510 BACKFILLING after execution of the WORK to proper grade and level with selected materials from available excavated soil from spoil heaps within a LEAD OF 100M, including re- excavating the deposited soil excavated earlier, breaking clods, laying at all depths and heights in layers of thickness not exceeding 15 Cms. watering, rolling and ramming by manual methods/ mechanical compactors to achieve 90% laboratory maximum dry density, dressing, trimming etc. in foundations, plinths, trenches, pits etc. all complete. 1511 BACKFILLING after execution of the WORK to proper grade and level with selected materials from available excavated soil from spoil heaps beyond a LEAD OF 100M AND UPTO & INCLUSIVE OF 500M including re-excavating the deposited soil excavated earlier, breaking clods, laying at all depths and heights in layers of thickness not exceeding 15 Cms. watering, rolling and ramming by manual methods/mechanical compactors to achieve 90% laboratory maximum dry density, dressing, trimming etc. in foundations, plinths, trenches, pits etc. all complete. 1512 Transporting & Disposing the SURPLUS EARTH ANDDEBRIS 1513 Transporting and disposing the SURPLUS EARTH AND DEBRIS including shrubs and vegetations from construction area beyond the initial LEAD OF 100M AND UPTO 1KM including re-excavating the deposited soil excavated earlier, transportation, loading, unloading, laying at all depths and heights, stacking, levelling and dressing both the area (viz. from where the earth is transported and where it is deposited) to required levels and slopes complete with all lifts as directed. For carting on the basis of truck measurements (volume of truck reduced by 30% for voids). 1514 Transporting and disposing the SURPLUS EARTH AND DEBRIS including shrubs and vegetations from construction area beyond the initial LEAD OF 1.0KM AND UPTO & INCLUSIVE OF 3.0KM including re-excavating the deposited soil excavated earlier, transportation, loading, unloading, laying at all depths and heights, stacking, levelling and dressing both the area (viz. from where the earth is transported and where it is deposited) to required levels and slopes complete with all lifts as directed. For carting on the basis of truck measurements (volume of truck reduced by 30% for voids). 1515 PLAIN & REINFORCED CEMENT CONCRETE: (REFER SPECIFICATION NO. 6-68-0004) 1516 PCC - Non FIM Items 1517 Providing and laying PLAIN CEMENT CONCRETE for all depths below and upto plinth level in foundations, drains, fillings, non-suspended floors, pavements & ramps or any other works etc. including shuttering, tamping, ramming, vibrating, curing etc. all as specified in any shape, position, thickness and finishing the top surface rough or smooth as specified and directed all complete for concrete of nominal mix 1:5:10 by mass (1 Cement: 5 Coarse Sand: 10 Crushed Stone Aggregates/Gravels) with 40mm and down size graded crushed stone aggregates/Gravels. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1518 Providing and laying PLAIN CEMENT CONCRETE for all depths below and upto plinth level in foundations, drains, fillings, non-suspended floors, pavements & ramps or any other works etc. including shuttering, tamping, ramming, vibrating, curing, etc. all as specified in any shape, position, thickness and finishing the top surface rough or smooth as specified and directed all complete for concrete grade M20 with 20mm and down size graded crushed stone aggregates/Gravels. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1519 RCC Substrutures - Non FIM Items 1520 Providing and laying REINFORCED CEMENT CONCRETE OF M-30 GRADE with 20 mm and down size graded crushed stone aggregates/ gravel in SUB-STRUCTURE e.g. foundations, raft, beams, slabs, pile caps, retaining walls, dyke walls, jambs, counterforts, buttresses, pedestals, pipe sleepers, columns, suspended floors, staircases, landings, steps, brackets etc., including equipment/ machine foundations & pedestals viz. compressors, ID & FD fans, pumps, generators, crushers, mills, etc., (including single pour concreting as specified on the drawing), applying cement wash on concrete surface (wherever no other surface application is specified), providing pockets, openings, recesses, chamfering, etc., wherever required, vibrating, tamping, curing and rendering if required to give a smooth and even surface etc. (EXCLUDING THE COST OF REINFORCEMENT, SHUTTERING & SPECIFIED ADMIXTURES) for all depths below and upto plinth level in any shape, position and thickness etc. all complete as specified, shown and directed. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1521 Providing and laying REINFORCED CEMENT CONCRETE OF M-30 GRADE with 20 mm and down size graded crushed stone aggregates/ gravel in SUB-STRUCTURE e.g. trenches, culverts, manholes, pipe encasement, catchpits, drains, pits, etc., applying cement wash on concrete surface (wherever no other surface application is specified), providing pockets, openings, recesses, chamfering, etc., wherever required, vibrating, tamping, curing and rendering if required to give a smooth and even surface etc. (EXCLUDING THE COST OF REINFORCEMENT, SHUTTERING & SPECIFIED ADMIXTURES) for all depths below and upto plinth level in any shape, position and thickness etc. all complete as specified, shown and directed. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1522 RCC Superstructures - Non FIM Items 1523 Providing and laying REINFORCED CEMENT CONCRETE OF M-30 GRADE with 20 mm and down size graded crushed stone aggregates/ gravel in SUPER STRUCTURE in suspended floors, slabs, beams, columns, walls including counterforts, staircases, landings, steps, facias, fins, mouldings, gutters, shelves, window sills, canopies, lintels, girders, ducts, brackets, chajjas with drip moulds, pedestals, posts, struts, equipment/ machine foundations, ramps etc. (including single pour concreting as specified on the drawing), providing cement wash (wherever no other surface application is specified), providing pockets, openings, recesses, chamfering wherever required, vibrating, tamping, curing and rendering if required to give a smooth and even surface etc. (EXCLUDING THE COST OF REINFORCEMENT, SHUTTERING AND SPECIFIED ADMIXTURES) FOR ALL HEIGHTS UPTO & INCLUSIVE OF 20 m ABOVE PLINTH LEVEL in any shape, position, thickness etc. all complete as specified, shown and directed. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1524 HYD Bars / MS Bars - Non FIM Items 1525 Supplying and placing in position HIGH YEILD-STRENGTH DEFORMED STEEL BARS REINFORCEMENT of Grade Fe500D (TMT) conforming to IS:1786, for RCC work including transporting the Steel, straightening, cleaning, decoiling, cutting, bending to required shapes and lengths as per details, binding with 18 SWG black soft annealed binding wire at every intersection, supplying and placing with proper cover blocks, supports, chairs, overlaps, welding, spacers, fanhooks etc. for all heights and depths etc. all complete as directed. SUPPLY OF ALL MATERIAL IN CONTRACTORS SCOPE. 1526 Centering and Shuttering - Non FIM Items 1527 Providing and fixing CENTERING AND SHUTTERING in foundations, footings,raft beams, slabs, pile caps, retaining walls, jambs, counter-forts, buttresses, trenches, equipment/machine foundations, pedestals, abutments, pipe sleepers, columns, plinth beams, lintels, suspended slabs, beams, staircases, landings, steps, non-circular tunnels/bunkers/ silos/ shafts/ hoppers/liquid storage structures etc. for all depths below and upto & inclusive of plinth level including shuttering for single pour concreting, strutting, bracing, propping etc., keeping the same in position during concreting and removal of the same after specified period etc. for Straight/ Inclined Shuttering, keeping necessary provision for inserts, projecting dowels, anchor bolts or any other fixture etc. all complete and as specified and directed. 1528 Providing and fixing CENTERING AND SHUTTERING in superstrctures in retaining walls, jambs, counter-forts, buttresses, equipment/ machine foundations, abutments,columns, lintels, suspended slabs, beams, staircases, landings, steps, non-circular tunnels/ bunkers/ silos/ shafts/ hoppers/ liquid storage structures etc. for all heights above plinth level including shuttering for single pour concreting, strutting, bracing, propping etc., keeping the same in position during concreting and removal of the same after specified period etc. for Straight/ Inclined Shuttering, keeping necessary provision for inserts, projecting dowels, anchor bolts or any other fixture etc. all complete and as specified and directed. 1529 Providing and fixing CENTERING AND SHUTTERING for CURVED SHUTTERING in foundations in all types of Structures such as Chimneys/ Shafts/ Silos/ tunnels/ bunkers/ hoppers/ liquid storage structures/ domes/ ring wall for tanks, etc. for all depths below and upto & inclusive of plinth level including shuttering for single pour concreting, strutting, bracing, propping etc., keeping the same in position during concreting and removal of the same after specified period etc. for Straight/ Inclined Shuttering, keeping necessary provision for inserts, projecting dowels, anchor bolts or any other fixture etc. all complete and as specified and directed. 1530 Providing and fixing CENTERING AND SHUTTERING for CURVED SHUTTERING in superstructures in all types of Structures such as Chimneys/Shafts/Silos/ tunnels/bunkers/hoppers /liquid storage structures/ domes etc. for all heights above plinth level including shuttering for single pour concreting, strutting, bracing, propping etc., keeping the same in position during concreting and removal of the same after specified period etc. for Straight/ Inclined Shuttering, keeping necessary provision for inserts, projecting dowels, anchor bolts or any other fixture etc. all complete and as specified and directed. 1531 Fixing Re-bars in already cast concrete - Non FIM Items 1532 Designing, supplying and fixing rebars in already cast concrete, including drilling, cleaning hole with air blow-out & wire-brush and injecting odourless Chemical of approved make, packed in dual foil, with the help of dispenser into a hole of diameter and depth as per manufacture specification, at all levels & locations for high strength deformed steel reinforcement bars of dia. 16 mm & 20 mm of Grade Fe500D (conforming to IS:1786), DESIGNED FOR FULL TENSILE ANCHORAGE, including testing (as per manufacturers recommendations), adjusting and making good any damage done to the structure etc. all complete as specified and directed. SUPPLY OF ALL MATERIAL IN CONTRACTORS SCOPE EXCLUDING REINFORCEMENT BARS. 1533 CONCRETE FOR LIQUID RETAINING/LEAK PROOF STRUCTURES (REFER SPECIFICATION NO.6-68-0005 1534 RCC- Non FIM Items 1535 Providing and laying Leak Proof Reinforced Cement Concrete of GRADE M-30 (minimum Cement content shall be as per EIL Specifications) with 20 mm and down size graded crushed stone aggregates/ gravel at all positions and in any shape and thickness, in SUB-STRUCTURE, leaving pockets, recesses, vibrating, tamping, curing, testing (for leak-proofness) and rendering (if required to give smooth and even surface) in foundations, walls , beams, buttresses, columns, piers, slabs, tunnels, basements, storage bins, reservoirs etc. including cement wash (if no other surface application is specified) but excluding the cost of Reinforcement, Shuttering and specified admixtures, all complete as specified and directed. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY CONTRACTOR. 1536 Water Proofing Comp. - Non FIM Items 1537 Supplying and mixing of approved brand of integral WATER PROOFING COMPOUND in cement concrete, cement mortar etc. as per manufacturers specifications or 1% by weight of cement (whichever is minimum), to make it leak proof/ water tight etc. all complete as specified and directed. 1538 PVC Water bars - Non FIM Items 1539 Supplying and fixing in position 230mm wide x 5mm thick approved PVC WATER STOPS as per manufacturers specifications in R.C.C. Structures including cutting, fixing, jointing by vulcanising etc. all complete as shown specified and directed. 1540 Separation Layer - NonFIM Item 1541 Supplying and laying separating layer of approved polythylene sheet of mass 1 kg/sqm (minimum) in between base slab and the layer of lean concrete, including cleaning, preparing of surfaces, etc., all complete and as directed by the engineer-in-charge. 1542 STRUCTURAL STEEL WORKSSPEC NO. 6-68-0006 1543 General Steel Works - FIM Items 1544 Transporting from storage yard (or any other location as specified by engineer-in-charge), Storing, Assembling and Erecting in position and testing/ examining, bolted and/ or welded, already Fabricated STRUCTURAL STEEL (of any Grade)at all locations and levels UPTO & INCLUSIVE OF 20 m ABOVE HPP/ FGL, including all builtup sections/ compound sections made out of rolled/ hollow sections and/or plates/ bent plates in all types of structural frameworks, fixing in line and level with temporary staging & bracing and removal of the same after erection, grouting with Ordinary Grout or premix free flow Nonshrink Grout as specified etc., all complete. ALREADY FABRICATED STRUCTURAL STEEL SHALL (WITH CONNECTION BOLTS) BE PROVIDED TO CONTRACTOR FREE OF COST. SUPPLY OF ALL OTHER MATERIAL IN CONTRACTORS SCOPE. 1545 General Steel Works - Non FIM Items 1546 Supplying, transporting, storing, fabricating & erecting in position and testing/ examining bolted and/ or welded STRUCTURAL STEEL WORKS of Grade E350BR / E350B0 (conforming to IS:2062) at all locations and levels UPTO & INCLUSIVE OF 20 m ABOVE HPP/ FGL, including all builtup sections/ compound sections made out of rolled sections and/ or plates/ bent plates in all types of structural frameworks, floor beams, stairs, or any other structural items or accessories to support equipments, piping, conveyor galleries, towers, masts, etc., but excluding silos, bunkers, hoppers, etc., cutting to required size, straightening/ bending if required, edge preparation, cleaning, preheating, bolting/ welding of joints, (including sealing the joints of box sections with continuous welding and plugging any open ends & holes of box sections), finishing edges by grinding, fixing in line and level with temporary staging & bracing and removal of the same after erection, grouting with Ordinary Grout or premix free flow Nonshrink Grout as specified, including preparation and submission of detailed fabrication drawings, preparing the surface for painting (SSPC-SP-10) and applying pre-erection/ shop primer (1 coat of F-9 @ 65-75 micron DFT) as per jOb Specification No. B861-000-06-42-PLS-01 after fabrication etc., all complete. SUPPLY OF ALL MATERIAL IN CONTRACTORS SCOPE. 1547 Painting - Non FIM Items 1548 Supplying and applying FIELD PAINT SYSTEM of approved quality and shade as per Sl. No. 5.2 of Table 5.0 of JOB Specification No. B861-000-06-42-PLS-01 over the coat of shop primer already applied, including storage, surface preparation, degreasing, cleaning, drying, providing necessary arrangement for access, testing etc. including touching up of shop primer coat as per Sl. No. 3.1 of Table 3.0 of JOB Specification No. B861-000-06-42-PLS-01 for steel structures (excluding ladders, spiral stairways & hand rails) at all location & levels, all complete as specified, in OFFISTE (COASTAL) areas as well as UNIT (INLAND & COASTAL) areas. SUPPLY OF ALL MATERIAL IN CONTRACTORS SCOPE. (Unit rate based on Structural steel weight). 1549 Supplying and applying COATING (Post-erection/ Field) of approved quality and shade as per Sl. No. 4.1 of Table 4.0 of JOB Specification No. B861-000-06-42-PLS-01 for painting over the coat of shop primer & galvanization already applied, including storage, surface preparation, degreasing, cleaning, drying, providing necessary arrangement for access, testing etc. including touching up of shop primer coat, for LADDERS, SPIRAL STAIRWAYS & HAND RAILS at all location & levels, all complete as specified. SUPPLY OF ALL MATERIAL IN CONTRACTORS SCOPE. (Unit rate based on weight of steel). 1550 STRUCTURAL STEEL WORKS (TUBULAR/HOLLOW SECTION) (REFER SPECIFICATION NO.6-68-0007) 1551 Yst310 IS 4923 1552 Supplying, transporting, storing, fabricating, erecting in position & testing/examining at all locations and levels, bolted and/or welded STRUCTURAL STEEL WORKS of all types using COLD FORMED (RECTANGULAR/SQUARE) HOLLOW SECTIONS conforming to IS: 4923, Grade Yst-310 of approved make in all type of trusses, purlins, girders, side rails, columns, runners, beams, ties, portals, framework, bracing, brackets, sag rods etc. including all handling straightening/ bending if required, cutting to required size & shape, edge preparation, welding & bolting of joints, providing and fixing end caps and plugging holes, fixing in line and level with necessary temporary staging and removal of the same after erection, grouting with Ordinary/ premix free flow Non- Shrink Grout as specified, preparation and submission of detailed fabrication drawings, preparing the exposed surfaces for painting (SSPC-SP-10) and applying pre-erection/ shop primer (1 coat of F-9 @ 65-75 micron DFT) as per Job Specification No. B861-000-06-42-PLS-01. all complete as specified and directed (SUPPLY OF ALL MATERIALS INCLUDING PLATES IN CONTRACTORS SCOPE) 1553 MISCELLANEOUS STEEL WORKS SPECIFICATIONS NO. 6-68-0008 1554 Anchor Bolts - Non FIM Items 1555 Supplying, fabricating, fixing and keeping in position at all levels and locations THREADED ANCHOR BOLTS of all diameters and nomenclature including nuts, washers, anchor plates, pipe sleeves etc. in foundations, columns, pedestals, slabs, beams, walls etc. or any other place as directed including handling & transporting, straightening if required, turning from relevant size M.S. rounds to required diameter, threading, welding, providing necessary templates and auxiliary dummy structures, if any, necessary tying and welding with reinforcement, adjustment of shuttering & reinforcement/any other fixture, greasing exposed metal surfaces, covering bolts and packing the sleeves with jute cloth etc. all complete as specified and directed.(SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). 1556 MS Metal Inserts - Non FIM Items 1557 Supplying, transporting, storing, fabricating and fixing in position M.S. METAL INSERT (with lugs) of any shape made out of flats, plates, rolled sections, pipes etc. providing necessary templates, staging, cutting, straightening, if required, bolting, welding as required and embedding in position on both Plain and Reinforced Cement concrete members inclusive of adjusting shuttering & reinforcement/ any other fixture, welding where necessary, tying and holding to correct level, line and position, any auxiliary dummy structures to support the heavy inserts, painting exposed surfaces with a coat of primer as per EIL Specification No. 6-79-0020 (or as per Job Specification wherever applicable), etc. all complete for all depths and heights as specified and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). 1558 GI Pipe Sleeves - Non FIM Items 1559 Supplying, fabricating and fixing in position G.I. PIPE SLEEVES of all diameters including providing necessary staging, cutting, straightening if required, bolting, welding as required and embedding in position on both Plain and Reinforced Cement concrete members inclusive of adjusting shuttering & reinforcement/any other fixture, welding where necessary, tying and holding to correct level, line and position, any auxiliary dummy structures to support heavy sleeves etc. all complete for all depths and heights as specified and directed. 1560 MS Chequered Plates - Non FIM Items 1561 Supplying, fabricating and erecting in position at all levels and locations bolted, screwed and/or welded M.S. CHEQUERED PLATES of any thickness in walkways, platforms, stair treads, any other place as directed etc. including cutting to required size, shape, making holes, notches, openings of required size, nosing, straightening if required, making the edges smooth, removing the burrs, fixing, welding, preparation and submission of fabrication drawings and preparing the surfaces for painting and applying shop primer as per EIL Specification No. 6-79-0020 (or Job Specification, wherever applicable) after fabrication etc. all complete as specified and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). 1562 MS Grating Cat. A,B - Non FIM Items 1563 Transporting from storage yard (or any other location as specified by engineer-incharge), Storing, Assembling and Erecting in position and testing/ examining, bolted and/ or welded, already Fabricated Grating for platforms etc., including cutting to required size, shape, making holes, notches, openings of required size, nosing, straightening, making the edges smooth, removing the burrs (if required), fixing, tack welding, all complete as specified and directed ALREADY FABRICATED GRATING (WITH CONNECTION BOLTS/CLAMPS) SHALL BE PROVIDED TO CONTRACTOR FREE OF COST. SUPPLY OF ALL OTHER MATERIAL IN CONTRACTORS SCOPE). 1564 Supplying, fabricating and erecting in position at all levels and locations ELECTROFORGED HOT-DIP GALVANISED GRATING (purchased from approved manufacturer by the Contractor) conforming to EIL Standard No. 7-68-0697 (in walkways, platforms, stair treads etc.) including cutting to required size, shape, making holes, notches, openings of required size, nosing, straightening if required, making the edges smooth, removing the burrs, fixing with manufacturers supplied Hot-dip galvanised clamps, preparation and submission of fabrication drawings, all complete as specified and directed. SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE. 1565 Making openings in galvanized grating for pipes / ducts etc., at all levels and at at all locations by cutting the existing grating and providing 50x6 galvanised flat as toe protection for the openings by welding and application of galvanized paint as per EIL Standard No. 7-68-0697, all complete. Payment shall be made as per number of openings. 1566 MS Rungs - Non FIM Items 1567 Supplying, fabricating, fixing and keeping in position M.S. RUNGS in R.C.C. works at all depths and heights including handling, transporting the steel to site workshop and site of work, straightening, if required, cutting, bending to shape, necessary tying and welding with reinforcement, adjustment of shuttering, cleaning, surface preparation, shop primer as per EIL Spec. 6-79-0020 (or Job Specification, wherever applicable)and two coats of anticorrosive paint of approved quality on the exposed portion of rungs etc. all complete as specified and directed (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). 1568 Hand Railing 1000mm - Non FIM Items 1569 Supplying, fabricating and fixing in position at all locations 1000mm high INCLINED HAND RAILING (for staircases) consisting of top rail, mid rail and vertical posts (Maximum spacing 1500mm c/c) with 32mm nominal diameter medium grade M.S. Tubes conforming to IS:1239 including straightening if required, cutting, bending, welding, bolting, grouting with ordinary grout, cleaning, surface preparation, hot-dip galvanising (80-85 micron as per IS:4759, IS:2629, IS: 4736, IS:2633), shop primer (1 coat of P6 of 40 micron) as per Sl. No. 4.1 of Table 4.0 of JOB SPEC. B861-000-06-42-PLS-01 preparation and submission of fabrication drawings etc. all complete as specified, shown and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). (Complete handrail work shall be measured as length of top rail only and not length of each element fixed). 1570 Supplying, fabricating and fixing in position at all locations 1000mm high HORIZONTAL HAND RAILING (for platforms, walkways, etc. or any other location as directed) consisting of top rail, mid rail and vertical posts (Maximum spacing 1500mm c/c) with 32mm nominal diameter medium grade MS Tubes conforming to IS:1239 and 100x5 MS Toe Plate confirming to IS:2062 (Grade A/B), including straightening if required, cutting, bending, welding, bolting, grouting with ordinary grout, cleaning, surface preparation, hot-dip galvanising (80-85 micron as per IS:4759, IS:2629, IS: 4736, IS:2633), shop primer (1 coat of P6 of 40 micron) as per Sl. No. 4.1 of Table 4.0 of JOB SPEC. B861-000-06-42-PLS-01, preparation and submission of fabrication drawings etc. all complete as specified, shown and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). (Complete handrail work shall be measured as length of top rail only and not length of each element fixed). 1571 Transporting from storage yard (or any other location as specified by engineer-incharge), Storing, Assembling and Erecting in position and testing/ examining, bolted and/ or welded, already Fabricated HAND RAILING for platforms etc. including straightening, cutting, bending (if required) welding, bolting, grouting with ordinary grout, all complete as specified and directed. ALREADY FABRICATED HANDRAILING (WITH CONNECTION BOLTS) SHALL BE PROVIDED TO CONTRACTOR FREE OF COST. SUPPLY OF ALL OTHER MATERIAL IN CONTRACTORS SCOPE. (Complete handrail workshall be measured as length of top rail only and not length of each element fixed) 1572 Mechanical Anchor fastners - Non FIM Items 1573 Supplying, handling, transporting to site of work and fixing approved MECHANICAL ANCHOR FASTENERS M.S. bolts of Grade 5.8 or more, GALVANIZED with minimum thickness of 5 microns (approved for use in cracked concrete), of 12mm dia at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturers specifications including all accessories like nuts, washers etc. of required size, testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush, and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed. 1574 Supplying, handling, transporting to site of work and fixing approved MECHANICAL ANCHOR FASTENERS M.S. bolts of Grade 5.8 or more, GALVANIZED with minimum thickness of 5 microns (approved for use in cracked concrete), of 16mm dia at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturers specifications including all accessories like nuts, washers etc. of required size, testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush, and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed. 1575 Chemical Anchor Fastner 1576 Supplying, handling, transporting to site of work and fixing approved CHEMICAL ANCHOR FASTENERS consisting of M.S. threaded rod of Grade 5.8, GALVANIZED with minimum thickness of 5 microns and chemical (approved for use in cracked concrete), packed in flexible chemical foil or dual foil type, to be usedwith the help of dispenser, of 12mm dia. at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturers specifications including all accessories like nuts, washers etc. of required size, testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed. 1577 Supplying, handling, transporting to site of work and fixing approved CHEMICAL ANCHOR FASTENERS consisting of M.S. threaded rod of Grade 5.8, GALVANIZED with minimum thickness of 5 microns and chemical (approved for use in cracked concrete), packed in flexible chemical foil or dual foil type, to be usedwith the help of dispenser, of 16mm dia. at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturers specifications including all accessories like nuts, washers etc. of required size., testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed. 1578 Supplying, handling, transporting to site of work and fixing approved CHEMICAL ANCHOR FASTENERS consisting of M.S. threaded rod of Grade 5.8, GALVANIZED with minimum thickness of 5 microns and chemical (approved for use in cracked concrete),packed in flexible chemical foil or dual foil type, to be usedwith the help of dispenser, of 20mm dia. at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturers specifications including all accessories like nuts, washers etc. of required size., testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed. 1579 Threaded bolts for equipment fixing-Non FIM 1580 Supplying, fabricating, fixing and keeping in position at all levels and locations THREADED BOLTS of Grade C property class 4.8 as per IS:1363 (part 2) of all diameters and length including nuts, washers for supporting equipment on steel structure as directed including handling & transporting, straightening if required, turning from relevant size M.S. rounds to required diameter, threading etc. (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). 1581 BRICK MASONRY (REFER SPECIFICATION NO.6-68-0009) 1582 CLASS 5.0at all depths -Non FIM Items 1583 Providing and laying BRICK MASONRY WITH BRICKS OF CLASS 5.0 in cement mortar 1:6 (1 Cement : 6 Sand) in one or more brick thickness and in any shape (excluding circular/curved brick masonry) at all depths below plinth level including the cost of materials, labour, scaffolding/ staging, sampling & testing, soaking of bricks, cutting and laying of bricks, providing recesses, making openings of any shape & size, finishing the joints flush below ground level and raking out the joints above ground level, sealing the gap between masonry and soffit of beam/slab, embedding the fittings & fixtures, curing, etc. all complete as per specifications. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1584 Providing and laying BRICK MASONRY WITH BRICKS OF CLASS 5.0 in cement mortar 1:6 (1 Cement : 6 Sand) in one or more brick thickness and in any shape (excluding circular/curved brick masonry) at all heights above plinth level including the cost of materials, labour, scaffolding/ staging, sampling & testing, soaking of bricks, cutting and laying of bricks, providing recesses, making openings of any shape & size, finishing the joints flush below ground level and raking out the joints above ground level, sealing the gap between masonry and soffit of beam/slab, embedding the fittings & fixtures, curing, etc. all complete as per specifications. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1585 HALF BRICK MASONARYwith bricks of CLASS 5.0-Non FIM Items 1586 Providing and laying HALF BRICK MASONRY with bricks of CLASS 5.0 in cement mortar 1:4 (1 Cement : 4 Sand)in any shape, including the cost of materials, labour, scaffolding/staging, sampling and testing, soaking of bricks, cutting and laying of bricks, providing openings of any shape & size, raking out the joints, supplying and placing 2 Nos. 6mm dia. M.S. Bars at every fourth course, sealing the gap between masonry and soffit of beam/slab, embedding the fittings and fixtures, curing etc. all complete as per specification. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY CONTRACTOR. 1587 DEMOLISHING AND DISMANTLING (REFER SPEC NO. 6-68-0012) 1588 Brickwork - Non FIM Items 1589 Demolishing BRICKWORK (taking all necessary safety precautions) for all depths below plinth level including supply of all tools and tackles, necessary scaffolding, propping, underpinning, cleaning and stacking of serviceable material, disposal of unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed. (Excavation & backfilling shall be paid separately under relevant items). 1590 Demolishing BRICKWORK (taking all necessary safety precautions) for all heights above plinth level including supply of all tools and tackles, necessary scaffolding, propping, underpinning, cleaning and stacking of serviceable material, disposal of unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed. 1591 RCC - Non FIM Items 1592 Demolishing RCC WORK (taking all necessary safety precautions) for all depths below plinth level including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc., cutting, straightening, scraping and cleaning of reinforcement bars, stacking of serviceable materials, disposal of unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed. (Excavation & backfilling shall be paid separately under relevant items). 1593 Demolishing RCC WORK (taking all necessary safety precautions) for all heights above plinth level including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc., cutting, straightening, scraping and cleaning of reinforcement bars, stacking of serviceable materials, disposal of unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed. 1594 Chipping of RCC WORK (taking all necessary safety precautions) by CHISELLING, upto & inclusive of 25mm thickness including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc., cutting, lapping/welding of reinforcement bars as per drawings, disposal of the unserviceable material to spoil heaps anywhere within the plant boundary, all complete at all heights and depths, as specified and directed. (Excavation and backfilling shall be paid separately under relevant items). 1595 Cutting/ Dismantling RCC work in pavement, slabs, beams, columns, etc upto a depth of 450 mm by using vibration-less spark-free Diamond Saw Cutter of make HILTI (or equivalent) at all depths & heights, in hazardous areas within process units & offsite which are fire prone due to presence of hydrocarbon vapours etc. taking elaborate precautions for dismantling as per fire permit, clearance etc. and work is to be done with extreme caution. The work item includes cost of all necessary accessories, tools & tacklesincluding diamond saw cutter, disposal of RCC Debris upto lead of 100 m& for all lifts (taking all safety precautions) including cutting reinforcement bars, embedded structural steel members, with necessary scaffolding, propping and underpinning etc. for all elevations with all labour and materials, all complete as per drawings, specifications and directions of the Engineer-in-charge. Payment will be made per sq.m.of cross-sectional cut area. Contractor to submit dismantling plan prior to start of dismantling. Dismantling shall be planned in such a way that each cut piece shall weigh not less than 1.6 MT. 1596 Cutting/ Dismantling of RCC block foundations, raft foundations, pile caps, mass concrete, equipment foundations etc. by using vibration-less spark-free Diamond Wire Saw Cutter of make HILTI (or equivalent) at all depths & heights, in hazardous areas within process units & offsite which are fire prone due to presence of hydrocarbon vapours etc. taking elaborate precautions for dismantling as per fire permit, clearance etc. and work is to be done with extreme caution. The work item includes cost of all necessary accessories, tools & tacklesincluding diamond saw cutter , disposal of RCC Debris upto lead of 100 m& for all lifts (taking all safety precautions) including cutting reinforcement bars, embedded structural steel members, with necessary scaffolding, propping and underpinning etc. for all elevations with all labour and materials complete as per drawings, specificationsand directions of the Engineer-in-charge. Payment will be made per sq.m.of cross-sectional cut area. Contractor to submit dismantling plan prior to start of dismantling. Dismantling shall be planned in such a way that each cut piece shall weigh not less than 1.6 MT. 1597 Pockets - Non FIM Items 1598 Making POCKETS/HOLES of sizes upto & inclusive of 200 x200x500mm in RCC/PCC works (taking all necessary safety precautions) by chiselling/drilling, including supply of all tools & tackles, necessary scaffolding etc. cutting of reinforcement bars, cleaning the pockets of all debris, disposal of the unserviceable material to spoil heaps anywhere within the plant boundary all complete at all heights & depths as specified and directed. 1599 PCC _ Non FIM Items 1600 Demolishing PLAIN CEMENT CONCRETE work (taking all necessary safety precautions) for all depths below plinth level including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc. disposal of unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed. (Excavation and backfilling shall be paid separately under relevant items) 1601 Demolishing PLAIN CEMENT CONCRETE work (taking all necessary safety precautions) for all depths below plinth level including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc. stacking of all the demolished concrete material at a designated location within the complex limits, all complete as per specifications and directions of Engineer-in-Charge for further processing in mechanical crushers for generating RA/ RCA as per the specifications. (Excavation & backfilling shall be paid separately under relevant items). 1602 Steelwork - Non FIM Items 1603 Dismantling bolted/rivetted/welded STRUCTURAL STEEL WORK of all descriptions (taking all necessary safety precautions), including supply of all tools and tackles, consumables, necessary scaffolding etc., providing temporary bracings as required, cutting (by flame or saw) gusset plates, bolts, nuts, weldings etc., transporting and stacking of the serviceable materials, cleaning the site of work of all unserviceable materials for disposal to spoil heaps anywhere within the plant boundary, all complete at all depths and heights, as specified and directed. 1604 MISCELLANEOUS ITEMS (REFER SPECIFICATION NO. 6-68-0013) 1605 Anticorrosive - Non FIM Items 1606 Providing and laying 50mm thick ANTI-CORROSIVE LAYER under steel storage tanks with screened dry coarse sand mixed with A90 grade bitumen conforming to IS:73 including mixing in drum, heating to the required temperature, with 3% kerosene if required, tamping, dressing to the required slopes to form hard mass of specified compacted thickness etc. all complete as directed. 1607 Sand Filling - Non FIM Items 1608 Supplying and filling approved SAND of specified quality under floors, in foundations, plinths, tank foundations etc. for all depths and heights including cost of sand, royalties, transportation to site for all leads and lifts, including loading, unloading, spreading in layers of loose thickness not exceeding 150 mm, watering, ramming, compacting with mechanical compactors and/or other equipment to the specified levels to achieve 85% relative density as per IS:2720 Part XIV, including preparation of subgrade to the required slope, providing testing apparatus and testing the degree of consolidation all complete as per drawings, specifications and direction of Engineer-in-charge. The rates shall be inclusive of the cost of all labour, material, equipments etc. all complete . 1609 BI-POLAR CONCRETE PENETRATING CORROSION INHIBITING ADMIXTURE 1610 Supplying and mixing of approved brand of BI-POLAR CONCRETE PENETRATING CORROSION INHIBITING ADMIXTURE (confirming to EIL Specification No. 6-68-0017) in concrete as per manufacturers specification for protection of reinforcement against corrosion. Supply of admixture in Contractors scope. 1611 BONDING FRESH CONCRETE TO OLD CONCRETE BY EPOXY RESIN BONDING SYSTEM (REFER SPECIFICATION NO. 6-68-0056) 1612 Epoxy Resin - non FIM Items 1613 Providing and applying approved EPOXY RESIN (prepared as per manufacturers recommendation) for bonding of fresh concrete to old concrete in all types of structure at all depths and heights including cleaning of concrete surface, removing of all loose concrete pieces, making rough by chiselling, taking off the skin of concrete, application of Epoxy Resin System by spraying, necessary working platforms, props, scaffolding and other safety measures, removal of same after completion etc. all complete as specified and directed. (Excavation, backfilling, removal of surplus earth, keeping pit dry by pumping/bailing subsoil water shall be paid separately under relevant items). 1614 FIREPROOFING OF STEEL STRUCTURES (REF SPEC NO 6-68-0033) 1615 Concrete - Non FIM Items 1616 Supply and laying of concrete of grade M30 as per Type-I of EIL Standard Specification 6-68-0033 as fire proofing material with 10 mm and down size graded coarse and fine aggregates including admixture around structural steel members (viz. beams, columns, bracings etc.) all complete; cleaning the steel surfaces, supplying, placing and fixing in position cover plates conforming to IS:2062 and stiffeners for members exceeding 600 mm depth, supply and welding ofMS nuts on angle and box sections and cover blocks for other sections, supplying, placing and fixing in position galvanized expanded metal sheet with mesh size 4.5 mm x 13.5 mm conforming to IS:412 except on angle and box sections, hot dipped galvanized welded wire fabric reinforcement 2 mm dia 50 mm x 50 mm mesh conforming to IS:1566, and tying the reinforcement to the cover blocks with galvanized 16 SWG tying wire, including cutting, straightening, cleaning, bending, vibrating, tamping, curing or providing a layer of approved membrane of curing compound, rendering with cement sand mortar (1:3) wherever required to achieve a smooth and even surface, providing L50x50x6 at corners or as specified in the drawing, applying primer on MS nuts, angles and affected surfaces, supplying and laying of non-bituminous polysulfide or silicon rubber mastic sealant at terminating edges/ metal joints, painting the surfaces with sealer coat of epoxy polyamide as base and finish coats of coating system No.1 of NORSOK Standard M-501, including the cost of all labour, materials, specified tests, shuttering, staging, scaffolding, working platforms, approaches, etc. for all shapes and positions at all heights upto & including 10 m above pavement etc. all complete as per specifications and directions of Engineer-in-Charge. (ALL MATERIALS INCLUDING CEMENT TO BE SUPPLIED BY THE CONTRACTOR). 1617 Vermiculite Concrete for Structural Steel - Non-FIM Items 1618 Supply and laying of vermiculite based lightweight cementitious concrete coating as per Type-II of EIL Standard Specification 6-68-0033 as fire proofing material of required thickness around structural steel members (viz. beams, columns, bracings etc.) for the required fire protection from reaching temperature 538 degree C; cleaning the steel surfaces and applying primer compatible to vermiculite material if required as per manufacturer specifications, supplying, placing and fixing in position cover plates conforming to IS:2062 and stiffeners for members exceeding 600 mm depth, supply and welding ofMS nuts on angle and box sections and cover blocks for other sections, supplying, placing and fixing in position galvanized expanded metal sheet with mesh size 4.5 mm x 13.5 mm conforming to IS:412 except on angle and box sections, hot dipped galvanized welded wire fabric reinforcement 2 mm dia 50 mm x 50 mm mesh conforming to IS:1566, and tying the reinforcement to the cover blocks with galvanized 16 SWG tying wire, including cutting, straightening, cleaning, bending, applying primer on MS nuts and affected surfaces, curing or providing a layer of approved membrane of curing compound, patching of damaged portion wherever required to achieve a smooth and even surface, providing chamfering at corners, supplying and laying of non-bituminous polysulfide or silicon rubber mastic sealant at terminating edges/ metal joints, painting the surfaces with sealer coat of epoxy polyamide as base and finish coats of coating system No.1 of NORSOK Standard M-501, including the cost of all labour, materials, specified tests, shuttering, staging, scaffolding, working platforms, approaches, etc. for all shapes and positions at all heights upto & including 10 m above pavement etc. all complete as per specifications and directions of Engineer-in-Charge. (ALL MATERIALS SHALL BE SUPPLIED BY THE CONTRACTOR). 1619 Supply and laying of vermiculite based lightweight cementitious concrete coating as per Type-II of EIL Standard Specification 6-68-0033 as fire proofing material of required thickness around structural steel members (viz. beams, columns, bracings etc.) for the required fire protection from reaching temperature 538 degree C; cleaning the steel surfaces and applying primer compatible to vermiculite material if required as per manufacturer specifications, supplying, placing and fixing in position cover plates conforming to IS:2062 and stiffeners for members exceeding 600 mm depth, supply and welding ofMS nuts on angle and box sections and cover blocks for other sections, supplying, placing and fixing in position galvanized expanded metal sheet with mesh size 4.5 mm x 13.5 mm conforming to IS:412 except on angle and box sections, hot dipped galvanized welded wire fabric reinforcement 2 mm dia 50 mm x 50 mm mesh conforming to IS:1566, and tying the reinforcement to the cover blocks with galvanized 16 SWG tying wire, including cutting, straightening, cleaning, bending, applying primer on MS nuts and affected surfaces, curing or providing a layer of approved membrane of curing compound, patching of damaged portion wherever required to achieve a smooth and even surface, providing chamfering at corners, supplying and laying of non-bituminous polysulfide or silicon rubber mastic sealant at terminating edges/ metal joints, painting the surfaces with sealer coat of epoxy polyamide as base and finish coats of coating system No.1 of NORSOK Standard M-501, including the cost of all labour, materials, specified tests, shuttering, staging, scaffolding, working platforms, approaches, etc. for all shapes and positions at all heights more than 10 m above pavement etc. all complete as per specifications and directions of Engineer-in-Charge. (ALL MATERIALS SHALL BE SUPPLIED BY THE CONTRACTOR). 1620 Vermiculite Concrete for Equipments - Non-FIM Items 1621 Supply and laying of vermiculite based lightweight cementitious concrete coating as per Type-III of EIL Standard Specification 6-68-0033 as fire proofing material of required thickness on equipment/ vessel skirts, saddles and supports for the required fire protection from reaching temperature 427 degree C; cleaning the steel surfaces and applying primer compatible to vermiculite material if required as per manufacturer specifications, supplying, placing and fixing in position cover plates conforming to IS:2062, hot dipped galvanized welded wire fabric reinforcement of 2 mm dia 50 mm x 50 mm mesh conforming to IS:1566 and tying the reinforcement with the pre welded nuts by galvanized 16 SWG tying wire, including straightening, cutting, bending of the reinforcement, including supplying and welding of additional MS nuts if directed by the Engineer-in-charge, applying primer wherever required, curing or providing a layer of approved membrane of curing compound, patching of damaged portion wherever required to achieve a smooth and even surface, providing chamfering at corners, supplying and laying of non-bituminous polysulfide or silicon rubber mastic sealant at terminating edges/ metal joints, painting the surfaces with sealer coat of epoxy polyamide as base and finish coats of coating system No.1 of NORSOK Standard M-501, including the cost of all labour, materials, specified tests, shuttering, staging, scaffolding, working platforms, approaches, etc. for all shapes and positions. all complete as per specifications and directions of Engineer-in-Charge. (ALL MATERIALS SHALL BE SUPPLIED BY THE CONTRACTOR). 1622 Mechanical works 1623 Supplying, fabricating and erecting in position MS plates as per detailed drawings, conforming to grade A of IS:2062 on top of all RCC pedestals supporting the sliding saddles of equipments, including cutting, straightening where necessary, rounding rounding unfinished edges by grinding, machining the exposed top surface, making necessary bolt holes, providing and laying ready mixed free flow non-shrink grout below the base plate at all levels & locations, machining top surfaces etc. all complete and as shown and directed. 1624 SAFETY (REFER EIL SPECIFICATION) 1625 Safety Structures - Non FIM Items 1626 Supplying, Transporting, Storing, Fabricating & Erecting in position and testing/ examining bolted and/ or welded Structural Steel Works at all locations and levels in HANGER SCAFFOLDING below piperack, comprising of hangar channels, fabricated pen wen ladder beams, steel planks bent to shape and size and any other sections, if required, all as per sketches/ specifications and load tested for statisfactory performance, including cutting to required size, straightening/ bending if required, edge preparation, cleaning, preheating, bolting/ welding of joints (including sealing the joints of box sections with continuous welding and plugging any open ends & holes of box sections), finishing edges by grinding, fixing in line and level with temporary staging & bracing and removal of the same after erection, including preparation and submission of detailed fabrication drawings, preparing the surface for painting as per BIS codes after fabrication etc. all complete as specified and directed. All items shall be removed & carried back by Contractor as per instructions of Engineer-in-Charge after completion of works. (Supply of All Material In Contractors Scope). 1627 Providing and fixing double scaffolding system of any height made with 40 mm dia MS tube 1.5 m centre to centre, horizontal & vertical tubes joining with MS tubes, MS tube challies, MS clamps and MS staircase system in the scaffolding for working platform/ staircase etc., and maintaining it in a serviceable condition for the required duration as approved and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc., wherever required for inspection of work at required locations with essential safety features for the workmen etc., all complete as per directions and approval of Engineer-in-charge. (Height shall be measured from Floor/ platform from where scaffolding is erected) including providing Aluminium ladders for safe acess of workers. 1628 Supply of Safety Personnel 1629 Supply of HSE personnel SAFETY STEWARD over and above the requirement as specified in EIL Standard Specification No. 6-82-0001 at site as per the written instructions of Engineer-in-charge (the rates shall be inclusive of all other payments such as PF, ESI, other benefits payable to the workmen as per the prevalent labour laws). 1630 Supply of HSE personnel SAFETY SUPERVISOR over and above the requirement as specified in EIL Standard Specification No. 6-82-0001 at site as per the written instructions of Engineer-in-charge (the rates shall be inclusive of all other payments such as PF, ESI, other benefits payable to the workmen as per the prevalent labour laws). 1631 Supply of HSE personnel SAFETY OFFICER over and above the requirement as specified in EIL Standard Specification No. 6-82-0001 at site as per the written instructions of Engineer-in-charge (the rates shall be inclusive of all other payments such as PF, ESI, other benefits payable to the workmen as per the prevalent labour laws). 1632 Supply of HSE personnel HOUSE-KEEPING SUPERVISOR over and above the requirement as specified in EIL Standard Specification No. 6-82-0001 at site as per the written instructions of Engineer-in-charge (the rates shall be inclusive of all other payments such as PF, ESI, other benefits payable to the workmen as per the prevalent labour laws). 1633 GENERAL CIVIL 1634 TANK PADS 1635 PVC Liner 1636 Providing and laying of PVC LINER of thickness 30 MIL conforming to IS:15909 below tank pad foundations or any other placeat all heights & depths without any damage during subsequent activities including handling, transportation, unloading, storage, laying in position, jointing & overlapping as per manufacturers recommendations, including supply and providing Asphalt impregnated fiberboards for anchoring, etc., all complete as per drawings, specifications and directions of Engineer-in-charge. (All materials including consumables shall be in contractors scope of supply) 1637 Providing and laying in position 80mm dia. perforated uPVC pipes conforming to IS:9271 wrapped with 125mm thick layer of 40mm down size stone aggregates in Geotextile fabric, Terrum T 700 / equivalent, below tank pad foundations for all heights & depths complete as per drawings, specifications and directions of Engineer-in-Charge. (All materials including consumables shall be in contractors scope of supply) 1638 Providing and installation of uPVC leak detection well arrangement comprising of 80mm dia. uPVC pipe, tee, blind flange & threaded cap conforming to IS:13592 for leak detection purpose below tank pad foundations at all heights & depths including providing proper jointing as per code requirements or manufacturers recommendations for fitting in already installed uPVC pipes etc. all complete as per drawings, specifications & directions of Engineer-in charge. 1639 GENERAL CIVIL 1640 SITE GRADING & ROCK CUTTING FOR SITE GRADING 1641 Earthwork in excavation for general site grading, roads, embankments, etc. for all heights and depths in all types of soils except soft and hard rock, including clearing and stripping of the areas earmarked for excavation, removing shrubs, grass, bushes, vegetables growth and other objectionable materials, trees up to and inclusive of a girth of 30 cms. (girth measured at a height of one meter from ground level) including uprooting of roots, etc. taking spot levels, excavating to required depth, leveling, dressing and consolidating the excavated surface, sorting out the excavated soil into serviceable and unserviceable materials, transporting and stacking serviceable materials to demarcated areas anywhere inside plant boundary limitas per instructions of Engineer-in-Charge and disposal of unserviceable material anywhere inside plant boundary limit. All complete as per drawings, specifications and directions of Engineer-in-Charge. 1642 ROADS & FLEXIBLE PAVEMENT (UPTO WBM/WMM LAYER) 1643 Earthwork in filling with approved available earth for all heights and depths for road embankments, shoulders or any other place as directed to proper levels, slopes, grades and camber with selected earth (having CBR 8%) obtained from approved approved areas for all leads from Complex Limit including excavation of earth at approved areas, clearing and stripping at approved areas (if necessary) loading, unloading, transportation etc., clearing and stripping as per specifications, uprooting of vegetation, roots and disposal of the shrubs, bushes, roots etc., breaking clods, spreading in layers not exceeding 20 cm loose thickness, watering, ramming and compacting with road roller to give at least 97% of laboratory dry density with heavy compaction as perIS:2720 Part-VIII, providing testing apparatus and testing the degree of consolidation, dressing and leveling, etc. complete including disposal of allunserviceable materials if any within the boundary limit for all leads etc. as per drawings, specifications and directions of Engineer-in- Charge. 1644 Supplying and Laying of Wet Mix Macadam (WMM) in BASE COURSE (Section 406 of MORTH Specification of Road & Bridge works) using tough, clean, sound & durable stone aggregates including premixing the material (mixing in Plug Mill/ Pan Type Mixer), including transportation to site, laying & spreading in layers not exceeding 125 mm compacted thickness & rolling with vibratory roller 80-100 KN static weight or equivalent capacity to proper grade, camber & level with all leads & liftsetc. complete as per drawing, specifications (MORTH, EIL) & directions of Engineer-in-Charge. 1645 Supply of forged/ cast fittings 1646 Supplying the following forged fittings and flanges, conforming to piping material specifications of tender documents and delivering the same to Owners stores/workspot etc. all complete as per the directions of Engineer-in- Charge. 1647 Elbow 90 Degree for following Nominal Sizes and Piping Material Class 1648 Dia. 12 InchPipe Class A33A 1649 Dia. 3 InchPipe Class A91A 1650 Elbow 45 Degree for following Nominal Sizes and Piping Material Class 1651 Dia. 6 InchPipe Class A33A 1652 Dia. 8 InchPipe Class A33A 1653 Dia. 12 InchPipe Class A33A 1654 Dia. 3 InchPipe Class A91A 1655 Eccentric Reducer for following Nom. Dia. 1 x Nom. Dia. 2 and Piping Material Class 1656 Nom. Dia. 1 8 InchNom. Dia. 2 6 InchPipe Class A94A 1657 Equal Tees for following Nominal Sizes and Piping Material Class 1658 Dia. 12 InchPipe Class A33A 1659 Dia. 3 InchPipe Class A91A 1660 Flanges, complete with nuts, bolts, gasket etc., for following Nominal Sizes and Piping Material Class 1661 Dia. 3 InchPipe Class A91A 1662 Supplying the following spectacle blind assembly consisting of two number flanges, spectacle blind, nuts, bolts, gasket etc. complete conforming to piping material specifications of tender documents and all complete as per the directions of Engineer-in-charge. For following nominal size and piping material class 1663 Dia. 3 InchPipe Class A91A 1664 MISC. CIVIL AND STRUCTURAL WORKS FOR U/G PIPING AND OTHER CIVIL WORKS 1665 Providing and laying brick masonry with locally available bricks of specified class (Brick of class lower than specifiedshall not be accepted) in cement mortar 1:4 (1 cement : 4 Coarse sand) in one or more brick thickness and in any shape in foundation and plinth for valve pits, drains, circular/square maholes, wing walls, etc. including providing recesses, openings, etc. including curing, finishing the joints flush below ground level and raking out joints in plinth with all labour and material, etc. complete as per drawings, specifications and direction of Engineer-in-Charge.For following Brick Class. 1666 All materials including cement supplied by the Contractor and Following Brick Class 1667 Brick Class 5 1668 Providing 13mm thick average cement plaster in cement mortar 1:3 (1 cement: 3 sand) on brick walls/stone masonry/pitching or on concrete surfaces for manholes, valves pits, culverts, wing walls, etc. including cleaning and preparation of the surface, scaffolding, curing etc. for all depths and heights complete as per drawings specifications and direction of Engineer-in-Charge. 1669 All materials including cement supplied by the Contractor. 1670 MISCELLANEOUS ITEMS 1671 Supply and installation of combined safety shower and eyewash units as per spec. no.6-66-0038, including providing and fixing of necessary foundation bolts in foundations/ pavement etc. complete. Each safety shower shall have proper sign board with florescent letters showing their location, all complete as per specification, drawings and direction of Engineer-in-charge. 1672 Supplying & Laying 60mm thick interlocking Paver Blocks for footpaths and any other place etc. including providing 40 mm thick sand filling below Paver Blocks including compaction of sand layer, filling the joints by dry sand, providing precast kerb stone of PCC M 30 at edges and at every 6.0m across the foot path, including preparation of compacted base/ sub base etc. all complete as per drawing, standard, specificationand directions of Engineer-in-Charge. (All material including cement supplied by contractor, paver blocks shall confirm to category A as per IRC SP63. Colour and shape of paver block shall be as per Owner requirement.). 1673 Modification Works 1674 MODIFICATION AND EXTRA WORKS ( IF ANY ) Cuting,bevelling,fitup,welding of different sizes of CS piping of all thicknesses in shop ,in position, on ground and at all elevations, transportation of pipes,fittings,flanges etc. from owners storage point to work site/workshop,making necessary scaffolding,consumables,machinery,tools,tackles,labour and supervision including attending to repairs for completing the work as per instructions of Engineer -in -charge 1675 Flame cutting CS piping 1676 Beveling CS piping 1677 Fit-up and welding CS piping 1678 Removal and re-installation of fire hydrant 1679 Removal and re-installation of firefighting equipment (Fire Hydrant), including isolation valve and transporting the equipment, valve, flanges from removal point to work spot, and fixing of nuts, bolts, washers, gaskets as needed for fixing the equipment with matching flange etc. complete, including plugging the existing branch with blind flange as per specification, drawings and directions of Engineer-in-charge. (Pipes and fittings shall be supplied by owner as free issue material) 1680 NDT Testing 1681 RADIOGRAPHY :- Performance of radiographic inspection on piping of all types & thicknesses including providing or hiring of all necessary equipment and whatever else even though not expressly mentioned but required to perform the work as per specificationsand instructions of Engineer-in-Charge. Radiographs shall be submitted to the Engineer-in-charge. (Repeat Radiography due to defective radiograph on repaired joints due to Contractors fault and for additional radiography necessitated due to poor performance of contractors welders shall be done at contractors cost) Note: Unit for radiography quantity is Nos of circumferential weld joints. 1682 FOR JOINTS THK. <= 8MM (FOR CS OTHER THAN CLASS lV OF SPEC FOR NDT REQUIREMENT OF PIPING) 1683 Nominal Dia. 3 Inch 1684 Nominal Dia. 4 Inch 1685 Nominal Dia. 6 Inch 1686 Nominal Dia. 8 Inch 1687 Nominal Dia. 12 Inch 1688 Micrograding 1689 Micrograding of the area as directed to proper level, grade and camber including earthwork in excavation in all types of soils up to a maximum depth of 150mm, removing shrubs, vegetation bushes, grass etc., earth work in filling with select material from available earlier excavated soil and borrow earth (in case the select material from excavated soil is short for filling, filling shall be done with borrow earth, supply & transportation of borrow earth shall be paid separately under relevant item) up to a maximum compacted thickness of 150mm by spreading in layers not exceeding200mm loose thickness, watering, ramming & compacting with road roller or hand roller including hand ramming where road rollers or hand rollers are not accessible to give at least 90% of max. laboratory dry density as per IS:2720 part VII, including transportation, leveling, dressing, disposal of surplus earth, debris, etc. all complete as per specifications, drawings and direction of Engineer-in-charge. (Disposal areas shall be anywhere within the plant complex limit as identified by Engineer-in-Charge.) 1690 Dismantling works 1691 Removal of existing A/G piping 1692 Removal of existing A/G piping of all thickness including cutting, unbolting of flanged joints / cutting of pipe lines wherever required, removing supports, all fittings, flanges etc., cutting of pipes in appropriate lengths for transporting purpose, transporting all material to owners storage point within the complex as designated by Owner including stacking of material and disposing of waste etc. as instructed by Engineer - in - charge. 1693 For C.S. A/G Pipe of following nominal dia. 1694 Nominal Dia 8 Inch 1695 Nominal Dia 4 Inch 1696 Nominal Dia 6 Inch 1697 Nominal Dia 12 Inch 1698 Removal of existing U/G piping 1699 Removal of existing U/G piping including excavation in all types of soils except soft rock and hard rock, including supply of any additional material required so as to expose the pipes for removal / dismantling, taking all safety precautions, supporting existing U/G services, dewatering of surface / sub-surface water as required to facilitate dismantling of pipes, cutting of pipes in appropriate lengths for transporting purpose, removal of soft material from bottom of trench and compacting, backfilling with available selected earth including re-excavating the deposited soil excavated earlier, breaking clods, laying in thickness not exceeding 15cms, watering rolling and ramming by manual methods / mechanical Compactors to achieve 90% laboratory maximum dry density as per IS:2720 Part VII or 85% relative density as per IS:2720 part XIV as applicable, stacking of serviceable / unserviceable material, transporting and stacking of all piping material to Owners storage point, disposal of unserviceable material anywhere inside the complex etc. , all complete as per directions of Engineer-in-Charge. 1700 For CS Piping dismantling, Thickness <=10 mm , For following Nominal Sizes 1701 NB 2 inch - 6 inch 1702 NB 8 inch - 14 inch 1703 Portable/ trolley mounted Extinguishers 1704 Supply and installation of portable DCP ( Dry Chemical Powder Type) extinguisher including transporting to worksite, fixing in position including all accessories and all labor and material etc. complete as per drawings, specification and directions of Engineer-in-Charge. 1705 Capacity in Kg 10 1706 Supply and installation of portable CO2 extinguishers including transporting to worksite, fixing in position including all accessories and all labor and material etc. complete as per drawings, specification, data sheet and directions of Engineer-in-Charge. 1707 Capacity in Kg 4.5 1708 Capacity in Kg 2 1709 Painting of A/G pipes and valves 1710 Supply of paints and primers, preparation of surfaces and application of primer and finish paints, identification (Line numbering), lettering, colour bands, colour coding etc. as specified including rubdown and touch up of shop primer wherever required, providing scaffolding for all heights, labour, material, tools and tackles, consumables supervision etc. to complete the work in all respects as per painting specification, drawings and direction of Engineer-in-Charge for all types of un insulated piping and insulated piping as specified including all pipes, fittings, flanges, supports, valves etc. Surface preparation by blast cleaning and application of first coat of primer (inorganic zinc silicate, F9) shall be done in fabrication yard prior to erection. The identification marks of the piping and joints shall be noted before blasting and the same shall be transferred on primed surface with Polyurethane paint (F2) or as per the instructions of Engineer-in-Charge. Notes: 1. All joints (fabrication as well as erection joints) shall be left unpainted till hydro testing. 2. No extra payment shall be made for identification (line numbering etc.) of insulated and uninsulated lines. 1711 Painting of uninsulated surfaces for Industrial marine environment as per painting specification for CS piping for design temp group: -14 to 80 (Deg C) including surface preparation. For following pipe sizes 1712 Nominal Dia. 12 Inch 1713 Nominal Dia. 4 Inch 1714 Nominal Dia. 3 Inch 1715 Nominal Dia. 6 Inch 1716 Nominal Dia. 8 Inch 1717 Painting of uninsulated surfaces for Industrial marine environment as per painting specification for CS piping for design temp group: -14 to 80 (Deg C) including surface preparation. For following valve sizes 1718 Dia. Of Valve 12 Inch 1719 Dia. Of Valve 4 Inch 1720 Dia. Of Valve 6 Inch 1721 Dia. Of Valve 3 Inch 1722 Dia. Of Valve 8 Inch 1723 Fabrication and Erection of piping (underground) 1724 FABRICATION AND ERECTION OF PIPING (SPEC. NO.6-65-0030 and 6-44-0012) : Laying and joining of Carbon Steel pipes and specials underground including transportation of all material from Owners storage point to worksite, earthwork in excavation in all types of soilEXCLUDING SOFT ROCK AND HARD ROCK for pipe trenches, saddles, etc. including dewatering of rain and /or sub soil water, shoring & strutting if required, dressing of sides, levelining, grading & ramming of bottom of trench, cutting of pipes if required, fitup, edge preparation, providing corrosion protection tape coating as per specification, on pipes and specials, laying the pipes in trenches to required alignment and levels, welding the same after laying, installation of flanges, blind flanges, tapping for pressure gauges, temperature gauges and all other online instruments and fittings like elbows, reducers, tees, flanges, spectacle blinds and spacer blinds etc., as per piping material specification, fixing of nuts, bolts, gaskets and washers, welding, corrosion protection coating of field joints, cutting of road wherever required and making good the same, testing for the corrosion protection coating as per specification, cleaning and flushing by water/ compressed air, hydrostatic/ pnuematic testing of the system, flushing, backfilling the trenches with select material from available excavated soil including re-excavating the deposited soil excavated earlier, breaking clods and laying in layers of 15 cm compacted thickness, watering, compacting with mechanical means like vibro rammers etc. to 90% of dry density as per IS:2720 Part-VII, disposal of surplus earth/ unserviceable material to demarcated area anywhere within the complex limit etc. complete as per drawings, specifications and instructions of Engineer-in-Charge including connecting the pipes to manhole, including return of all unused / scrap pipe to owners storage point (Pipes and fittings shall be supplied by owner as free issuematerial.) (Depth of excavation for pipe trench shall be upto 3.0m) 1725 Carbon SteelPiping (Non IBR), Thickness <=10 mm 1726 Fabrication, For the following nominal sizes 1727 NB 2 inch - 6 inch 1728 NB 8 inch - 14 inch 1729 Erection including corrosion protection coating, for Water System (Pressure Piping), Forfollowing Nominal Sizes 1730 NB 2 inch - 6 inch 1731 NB 8 inch - 14 inch 1732 Erection including corrosion protection coating, for Waste Water Collection System (Gravity Flow), for following Nominal Sizes 1733 NB 2 inch - 6 inch 1734 Fabrication and Erection of piping (Above ground) 1735 PIPING (ABOVE GROUND): Transportation of all piping items from owners storage point to work site/workshop, fabrication including cutting, edge preparation (including grinding the edges of pipe, fittings, flanges etc. to match with the mating edges of uneven/different thickness wherever required), fitup, bending, preheating wherever required, welding, threading, and laying of pipes of all type and thickness over pipe sleepers, overhead on racks and at all elevations, connectingwith equipment nozzles, strainers, orifice assemblies, tapping for pressure gauges etc., fixing of gaskets, bolts, nuts including application of torque wherever required and all other inline instruments and fitting like elbows, reducers, tees, vents, drains, SW valves upto 1.5 NB, alignment, cleaning & flushing by water/compressed air, hydrostatic, pneumatic, vacuum, spark testing and any other type of testing as specified,draining, drying by compressed air completing all such works in all respects (including preparation of isometrics as mentioned in the scope of work for the job)as per drawings, specifications and instruction of Engineer-in-charge. (Pipes and fittings shall be supplied by owner as free issue material) 1736 Carbon SteelPiping (Non IBR), Thickness <=10 mm 1737 Fabrication, For the following nominal sizes 1738 NB 2 inch - 6 inch 1739 NB 8 inch -14 inch 1740 Erection , for Water System (Pressure Piping), Forfollowing Nominal Sizes 1741 NB 2 inch - 6 inch 1742 NB 8 inch -14 inch 1743 Supply of Carbon steel pipes 1744 Supply of Carbon steel pipes as per Piping material class including transportation of all material to owners store complete as per drawings, specifications and instruction of Engineer-in-Charge. For following nominal size and piping material class. 1745 Nominal Dia. 12 InchPiping Material Class A33A 1746 Nominal Dia. 4 InchPiping Material Class A33A 1747 Nominal Dia. 8 InchPiping Material Class A33A 1748 Nominal Dia. 6 InchPiping Material Class A33A 1749 Nominal Dia. 3 InchPiping Material Class A91A 1750 Supply and installation of valve assembly, flange assembly etc. 1751 Supply and installation of valve assembly consisting of valve, 2 no. flanges, 2 no. gaskets and 2 sets of nuts & bolts per valve assembly, erection of valve in position including fixing of nuts, bolts, gaskets, washers etc. complete as per drawings, specifications and directions of Engineer-in-Charge. 1752 Gate valve assembly for following nominal sizes and piping material class 1753 Dia. 12 InchPMS A33A 1754 Dia. 8 InchPMS A33A 1755 Dia. 6 InchPMS A33A 1756 Dia. 3 InchPMS A91A 1757 Supply and installation of valve assembly consisting of valve, 1 no. flange, 2 no. gaskets and 2 sets of nuts & bolts per valve assembly, erection of valve in position including fixing of nuts, bolts, gaskets, washers etc. complete as per drawings, specifications and directions of Engineer-in-Charge. 1758 Dia. 4 InchPMS A33A 1759 Dia. 6 InchPMS A33A 1760 Globe valve assembly for following nominal sizes and piping material class 1761 Dia. 3 InchPMS A91A 1762 Supplying the flange assembly conforming to piping material specifications and delivering the same to owners stores/ work spot etc. Flange assembly shall consist of 2 no. flanges along with one no. matching gasket and one set of matching nuts &, bolts. All complete as per specifications and directions of Engineer-in-Charge. For following nominal size and piping material class 1763 Dia. 3 InchPMS A91A 1764 Supply, Fabrication and installation of strainers 1765 Supply, Fabrication and installation of strainers as per drawingsetc. complete as per specifications and directions of Engineer-in-Charge. 1766 T-type strainers for following nominal size and piping material class 1767 Dia. 3 InchPMS A91A 1768 fire fighting equipments 1769 Supply, installation, testing and commissioning of following firefighting equipment as per relevant specifications, data sheet, drawing, including transporting the equipment to worksite, fixing of nuts, bolts, washers, gaskets, welding needed for fixing the equipment with matching flange etc. all complete as per drawings, specifications, standards, data sheet and direction of Engineer-in-Charge. 1770 Double headed landing valve 1771 First Aid hose reel wall mounted type 1772 Hose box cabinet Type-II (Wall mounted type) including all inside accessories, including all civil works, fixing in position with anchor bolts in foundations or wall 1773 Hose box cabinet Type-II (self-supporting type) including all inside accessories, including all civil works, fixing in position with anchor bolts in foundations or wall 1774 Variable flow Water cum foam monitor of 500/750/1000 GPM capacity 1775 Stand Post Type Fire Hydrant without Pumper Connection 1776 Miscellaneous Items 1777 Miscellaneous 1778 Design, engineering, procurement, supply of all materials and equipment, machinery, civil, structural, electrical, mechanical, instrumentation, piping works including painting works, tape coating on U/G piping, commissioning spares and tools/tackles as per scope of work, specifications, drawings, data sheets etc. and as per directions of Engineer-in-Charge for Auto Actuated High Velocity Spray System on Transformers including taking approval of the complete system from agency appointed by insurance company /Client. Unloading at site, handling, transportation from store to work site, storage at site, fabrication, construction, assembly at site, supply of all labour, installation, field works including civil structural, electrical, mechanical, instrumentation, piping works and supports, testing, pre-commissioning, painting, commissioning and any other activity required to complete the works in all respects including performance guarantee run, handing over to client as per enclosed scope of work, drawings, specifications, instructions to vendors, data sheets and as per directions of Engineer in- Charge. Supply of mandatory spares as per specifications enclosed list/instructions to vendor as per scope of work and specification, drawings and documents as per attached vendor data requirement for all supplies and services etc. complete.
Contract Date : Ref. Documents   |   Contract Value : Ref. Documents
BRR : 7276865 Tender For Supply Of All Materials, Labour For Construction Of Oht, Cwr, Ph, Sq, Bw, Distribution System, Rm, Tw With Scada Automation As Per Specifications In Tender Document Complete In All Respect Hardoi Npp Reorganization Wss Under Amrut 2.0, Supply of all materials, labour, T&P etc. for Construction of Over Head Tanks, CWR, Pump house, Staff Quarter, Boundary wall, gate, Site development, Supply of all materials for laying & jointing of rising main, distribution system including all labour and T&P etc. complete in all respects and construction of tubewells including PLC SCADA automation of all tubewells as per specifications in tender document complete in all respect including commissioning, testing, trial & run, defect liabilities and handing over the complete works to Hardoi Nagar Palika Prishad Reorganization water supply scheme on turn-key basis Under AMRUT 2.0 Programme Sl. No. Item Description 1 A - Civil works :-Structural design and drawing must be vetted by any IIT (Indian Institute of Technology) of India, Supply of all materials, labour, T&P etc required for construction of Intz type RCC over head tank including various works like - Ventilator and Water level indicator, Lightening conductor, D.I. D/F Verticle pipes (Inlet Pipe, Outlet Pipe, Overflow Pipe & Washout Pipe), over flow pipe connect with distribution main with NRV of required dia with all necessary fittings such as sluice valve, NRV and their chamber as per design and specification and place decided by engineer in charge, duck foot bend, puddle collers and bell mouths, Sluice valve on inlet, outlet & washout pipe and sluice salve chamber, bye-pass arrangement of OHT, flooring, apran & drain (100 mm thick PCC of1:1.5:3& 100 mm thick RCC of 1:1:2 ), floor two coat apex weather coat (Asian, Berger etc.) painting over one coat primer of approved colour over wall putty two coat (Birla, JK, Asian, Berger etc.) after finishing of RCC surface with grinder, repair of pin holes, unevenness., railings- 20 mm G.I. pipe class - B railing around stair case (both sides), balcony & top dome periphery in three rows with MS angle iron post 50x50x6 in one metre distance, M.S ladder from opening of top dome to bottom dome 65x65x6 with 20 mm steel round bar, Stair case (Seperate two column based RCC staircase upto top dome and 1 m wide balcony with arrangement of M.S Gate and MS square mesh), Food grade epoxy coating of FOSROC / Ciba-Geigy or reputated brand on inside surface area of water container after testing for water tightness, of capacity and staging mentioned as under:For bidding purpose, bearing capacity of soil shall be considered as 8t/sq.m. Working design shall be based on the SBC determind after soil investigation / 8 tonne/sqm including required earthfilling for maintainingFGL as per level of nearest road cost of earth required for filling not to be paid extra.Note :- The bid price of over head tanks is to be submitted considering net safe allowable bearing capacity as 8 t/m2, keeping the minimum foundation depth to be 2.5 m below existing ground level at the site of work, layout as ground level of over head tank consider from 50 cm above than near of road surface to be finalized by the engineer in charge including, campus cleaning, removal of debries, bush cutting and disposal within municipal limt and filling ogf earth if required as per direction of Engineer in charge.The successful bidder will be required to investigate the soil bearing capacity. If net safe allowable bearing capacity is found to be equivalent or more than 8 t/m2, the design of OHT will be based on 8 t/m2 capacity. However, in case the net safe allowable bearing capacity is found to be below 8 t/m2, then the design of OHT will be based on the actual bearing capacity. 2 Over Head Tank - 1400 KL / 24 M Staging at Zone VI 3 Over Head Tank - 1100 KL / 24 M Staging at Zone IX 4 Structural Design, supply of all material, labour, T&P etc. required for construction of Ractangular, R.C.C Clear Water Reservoir cum pump house to accomadate 3 no of pumping plants and other appurtenant work etc as per IS 3370-1965 (Part I to IV) or its latest amendments. Structural design and drawing must be vetted by any IIT (Indian Institute of Technology) of India. The design will be based on all relevant technical specification asgiven herewith in bid document. A separate room of not less than 3.00x3.00m in size should be provided by the side of the pump house for record keeping.Provision for fixing ofinlet pipe equivalent to no of TWs to be connected to CWRand over flow pipe of required dia with all necessary fittings such as sluice valve, NRVand their chamber as per design and specification and place decided by engineer in charge. The floor of pump house and top of CWR and the room provided at the side of pump house should be 25mm KOTA stone flooring. The size of CWR pump house should be such that all the motor pump starters O.C.B. cables, water level indicator all piping arrangement, reflex valve sluice valve etcmay be accommodated in the pump house.Architectural view and GA drawing of pump house shall be approved by department before execution of work.The pump house will be constructed with all appurtenant work such as fixing of door window grill shutter and collapsible door if required suitable gantry beam with rail electronic water level indicator as given in detail specification including necessary glazed door, Two coat apex weather coat (Asian, Berger etc.) painting over one coat primer of approved colour over wall putty two coat (Birla, JK, Asian, Berger etc.) 1 m wide RCC stair case with stainless steel hand railing to go inside reservoir, sump below the pump house area, Railing - 20 mm G.I. Pipe class - B in three rows with MS angle iron post 50x50x6 in one metre distance over the R.C.C slab of reservoir, Granular texture finish on exterior surface of pump house, gantry beam, food grade epoxy coating of FOSROC / Ciba-Geigy or reputated brand on inside surface area of water container after testing for water tightness, of capacity mentioned as under:Note : The bid prices of Clear Water Reservoir / Pumping Stations are to be submitted considering the depth of excavation may extend up to 6 m BGL, layout as ground level of over head tank consider from 50 cm above than near of road surface to be finalized by the engineer in charge. 5 Clear Water Reservoir - 500 KL at Zone VI 6 Demolishing of existing OHT in Zone VIDemolishing of existing over head tank capacity 2000 KL/ 18 M Staging by manually / mechanical process with proper barricating and necessary safety arrangements including stacking of serviceable materials i.e. pipes, steel, sluice valve etc. at a suitable & secured place with own expense of contractor and disposal of unserviceable materials/ scraps within distance of 8 km distance in municipal limit as per direction of engineer in charge including supply of all machinery, T&P, labour etc. required for proper completion of the work. 7 Design of distribution network and supply of following dia of high density polyethelene Pipes (HDPE(PN-6)/PE-100), conforming to IS 4984 / 14151 / 12786 / 13488 in coils/ standard lengths with nesessary jointing material like electro-fusion coupler, flanged joint, including all statutary duties and taxes, third party inspection charges, transit insurance, freight, transportation to store/ site of work, unloading & stacking the same in covered shade duly protecting from sunrays & rains including crossing of upto 1.00 m vide nala/drain etc. with Carting, lowering, laying and requisite specials to site of work, lowering them into trenches, laying true to alignment and gradient, in proper position, cutting of pipes, making of joints including cost of jointing materials and rubber rings, labour, T&P, including hydraulic testing etc. complete as directed by Engineer in-charge.It includes provision for making of alignment on city roads, making trial pits to investigate location of various under grounds services like telephone cables, electric cable, existing pipe lines and sewer lines etc. arrangements for diversion of traffic and associated works etc. with supply of all necessary equipment, materials, labour and T&P etc. complete required for completion of work.The trenches shall be properly barricaded and fenced off wherever necessary. Red flags and caution boards during day and red lights during night shall be displayed so as to avoid any accidents. Note: Jointing between HDPE pipes and specials shall be done as per the latest IS: 7634 part II. Only Bar coded electro-fusion machine (automatically readable) that can read the bar code of the fittings automatically shall be used for jointing of HDPE pipe/fittings. Note: 1. Contractor will ensure to supply of 10 No. set of electrofusion jointing machine including cutting & peeling tool andother misc. equipments.2. Contractor will provide 04 No. set of hydro testing machine of 20 kg/cm² capacity including 02 Nos. tractor with water tanker will also be part of this set.3. Contractor will provide minimum 06 tractor trolley for disposal of surplus earth.4. Contractor will provide 04 No. of tractor with water tanker for sprinkling of water on trenches and 5 No. Anti Smoke Gun to protect the dust particals entering in the atmosphere which may be cause of increase of AQI of construction area. 8 HDPE Pipe 90 mm dia 9 HDPE Pipe 110 mm dia 10 HDPE Pipe 140 mm dia 11 HDPE Pipe 160 mm dia 12 Design of distribution network and supply of following dia of ISI marked S & S centrifugally cast (Spun) ductile iron pipes (Class K-7) as per IS : 8329-2000 suitable for push on jointing by compatible rubber gasket including all statutary duties and taxes, third party inspection charges, transit insurance, freight, transportation to store/ site of work, unloading, stacking,including crossing of upto 1.00 m vide nala/drain etc. Carting, lowering, laying and jointing with SBR ruber gasketsD.I. K-7 pipes of following dia & pressure including all specials, to site of work, lowering them into trenches, laying true to alignment and gradient, in proper position, cutting of pipes, making of joints including cost of jointing materials and rubber rings, labour, T&P, including hydraulic testing etc. complete as directed by Engineer in-charge. It includes provision for making of alignment on city roads, making trial pits to investigate location of various under grounds services like telephone cables, electric cable, existing pipe lines and sewer lines etc. arrangements for diversion of traffic and associated works etc. with supply of all necessary equipment, materials, labour and T&P etc. complete required for completion of work. The trenches shall be properly barricaded and fenced off wherever necessary. Red flags and caution boards during day and red lights during night shall be displayed so as to avoid any accidents. Note : Only SBR Rubber gaskets to be used as per IS-5382 and IS- 12820. 13 DI Pipe (Class K-7) 200 mm dia 14 DI Pipe (Class K-7) 250 mm dia 15 DI Pipe (Class K-7) 300 mm dia 16 Risingmain :-Supply of following dia of ISI marked S & SCentrifugally Cast (Spun) Ductile Iron pipes (Class K-9) as per IS : 8329-2000 suitable for Push on jointing by compatible rubber gasket including all statutary duties and taxes, third party inspection charges, transit insurance, freight, transportation to store/ site of work, unloading, stacking,including crossing of upto 1.00 m vide nala/drain etc. Carting, lowering, laying and jointing with SBR ruber gasketsD.I. K-9 pipes of following dia & pressure including all specials, to site of work, lowering them into trenches, laying true to alignment and gradient, in proper position, cutting of pipes, making of joints including cost of jointing materials and rubber rings, labour, T&P, including hydraulic testing etc. complete as directed by Engineer in-charge. It includes provision for making of alignment on city roads, making trial pits to investigate location of various under grounds services like telephone cables, electric cable, existing pipe lines and sewer lines etc. arrangements for diversion of traffic and associated works etc. with supply of all necessary equipment, materials, labour and T&P etc. complete required for completion of work. The trenches shall be properly barricaded and fenced off wherever necessary. Red flags and caution boards during day and red lights during night shall be displayed so as to avoid any accidents. Note : Only SBR Rubber gaskets to be used as per IS-5382 and IS- 12820. 17 DI Pipe (Class K-9) 200 mm dia 18 DI Pipe (Class K-9) 250 mm dia 19 Earth work in excavation for pipeline trenches in all type of soil with including lift upto 1.5 m and lead upto 50M, refilling the soil as required, including depositing in layers not exceeding 150mm, watering and compaction to 95% of the Standard Proctor density, level dressing, including supply of all labour, T&P etc. required for proper completion of the work. Including disposal of surplus earth up to 8 Km as instucted by engineer in charge. 20 Supply of following sizes of DI D/F sluice valve/scour valvewith cap. Class-10 (working pressure 10kg/sqcm) confirming to IS:14846:2000 at Site of work, carting, lowering in already prepared trenches and fixing them in position, making flange joints including supply of all materials such as bolts, nuts, rubber insertion, white lead, testing etc. complete including all other necessary fitting and specials as per direction of Engineer in charge. 21 80 mm dia 22 100 mm dia 23 125 mm dia 24 150 mm dia 25 200 mm dia 26 250 mm dia 27 Scoure valve 28 80 mm dia 29 Supply of following size Kinetic Double Air Valves as per IS : 14845 at site of work, carting, fixing in position including boring and threading in the main etc.complete including cost of boring the water main clamp with socket, G.I. medium duty, nipple and subsequent back filling etc complete. 30 25 mm 31 Supply of 80 mm dia size flanged type fire hydrant site of works of 80mm dia size flanged fire hydrant to site of work, fixing them in position for flanged joints s instucted by engineer in charge. 32 Supply of all materials, labour, T&P etc. and construction of following chambers as per departmental type drawing and designincluding supply & fixing of RCC cover etc. complete including all other necessary fitting as per direction of Engineer in charge. 33 Surface box type 34 Masonry type 35 For air valve 36 For fire Hydrants 37 Construction of RCC thrusht block in 1:1.5:3 with cement, coarse sand and 20 mm guage stone gtit at bends of pipe including supply of all materials, labour, T&P etc. required for proper completion of work 38 Mild steel TMT.Fe-500D in plain work such as reinforced concrete or reinforced brick work (for construction of RCC thrusht block) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and othorised overlapping shall be measured upto floor two level. 39 Dismantling of following type of road surface including sorting out and stacking of serviceable materials and disposal of unserviceable materials upto distance of 8km. and also including temporary reinstatement/motorable of road by old materials. 40 B.O.E. road 41 Bituminous road 42 C.C. road 43 Interlocking road 44 Permanent re-instatement of following type of road surfaces after laying of pipe line including supply of all materials, labour, T&P etc. required for completion of work. It also includes necessary excavation required for preparation of trench for reinstatement of road, disposal of surplus unserviceable material, watering, ramming, cleaning of surface for proper completion of the work as per directions of engineer-in-charge. 45 Brick on edge with bricks (60 % New & 40% Old) laid dry, joints filled with local sand including preparation of base to proper slope and its ramming, spreading a layer of 10 cm depth of local sand over the subgrade and including supply of all materials, labour, T&P etc. required for proper complete of the work. 46 Brick on edge with bricks (100 % New) laid dry, joints filled with local sand including preparation of base to proper slope and its ramming, spreading a layer of 10 cm depth of local sand over the subgrade and including supply of all materials, labour, T&P etc. required for proper complete of the work. 47 Re-instatement of bitumen road as per specification including supply of all materials, labour, T&P etc. required for proper completion of work. To achive the required quality of work, graded material in appropriate quantity shall be supplied by the contractor. This material shall be used in filling of trenches onlyafter succesfully testing of material with relevent IS code. Sample collection of GSB material, BM and SDBC will be done asrequired by engineer incharge. 48 Re-instatement of bitumen road as per specification including supply of all materials, labour, T&P etc. required for proper completion of work. To achive the required quality of work, graded material in appropriate quantity shall be supplied by the contractor. This material shall be used in filling of trenches onlyafter succesfully testing of material with relevent IS code. Sample collection of GSB material, BM and SDBC will be done asrequired by engineer incharge. (PWD Road) 49 Surface layer painting in Bituminous road including supply of all materials, labour, T&P etc. required for proper complete of the workas per directions of engineer-in-charge. 50 Providing and laying design mix cement concrete 100 mm thick of M-20 grade, in roads, using cement content as per design mix, using coarse sand and graded stone aggregate of 20 mm nominal size in appropriate proportions as per approved & specified design criteria, mixing with weigh batcher, laying at site, spreading and mechanically compacting by using needle and surface vibrators, levelling to required slope / camber, finishing with required texture over 100 mm thick base of GSB. 51 Providing and laying of 80 mm thick M-30 grade C.C. rubber moulded (60% new and 40% old tiles) interlocking paver tiles over 30 mm thick fine sand bed and also including earth wotk in excavation in proper slope & camber including all materials, labour, T&P required for proper completion of work. 52 Providing and laying of 80 mm thick M-30 grade C.C. rubber moulded (100% new tiles) interlocking paver tiles over 30 mm thick fine sand bed and also including earth wotk in excavation in proper slope & camber including all materials, labour, T&P required for proper completion of work. 53 Provision for crossing of nala, road, culvert including supply of casing with MS / DI pipe and specials, laying, jointing etc., T&P and arrangement of diversion of water, baricatings etc required, with dismantelling of drains and reconstruction of same as per type design of the existing drain, complete as per direction / approval of Engineer in charge.up to 1.00 M 54 Crossing of Culvert/ nala upto 3.5M width using casing of pipes restoring than drain original condition for laying pipe line including supply and materials labour, T&P etc. complete 55 Crossing of Culvert/ nala from 3.5M to 7.0M width using casing of pipes restoring than drain original condition for laying pipe line including supply and materials labour, T&P etc. complete 56 Crossing of Road upto 3.5M for laying pipe line including supply and materials labour, T&P etc. complete. 57 Crossing of Road from 3.5M to 7.0 M for laying pipe line including supply and materials labour, T&P etc. complete 58 Trenchless Crossing :- Survey site Investigation Planningdesign Drawings as per State Road manual and vetting / checked from State Road Divisional Office and taking NOC for trenchless crossing of National highway road and Railway track(crossing length 15m to 25m ) Road for of required dia Rising main pipe with casing pipe as required for proper completion of work required size of MS casing pipe as per drawing and as per (IS:3589 & made from confining to IS:2062) with 750 Micron PU coating internally and 250 micron anti corrosive bituminous paint externally by trenchless technology method at an average depth 3.60 mtr from normal ground level up to top of casing pipe including excavation & filling of Pit Dewatering arrangement Supporting system for soil also including supply and fixing of 2 no Sluice valve ISI Mark construction of sluice valve chamber etc. all complete work including supply & fixing specials in carrier pipe over main pipe as per specification given in the bid documents including supply of all materials labour T&P etc. for proper completion of work as per instruction of Engineer (charges include for all type of NOC/Approval providing by concern department) 59 National Highway road crossing (upto 350 mm dia) 60 Railway line crossing (upto 350 mm dia) 61 Making interconnection in 90 to 500 mm dia AC/ P.V.C./ HDPE/DI pipes including supply, carting of specials, lowering them into tranches, cutting, fixing them in proper alignment and jointing including balling out of water, necessary excavation for connection and proper barricading including supply of all machinery, T&P, labour etc. required for proper completion of the work as per directions of engineer-in-charge. 62 400 mm to 400 mm 63 400 mm to 160 mm 64 400 mm to 90 mm 65 350 mm to 250 mm 66 350 mm to 160 mm 67 350 mm to 90 mm 68 300 mm to 90 mm 69 250 mm to 200 mm 70 250 mm to 90 mm 71 200 mm to 140 mm 72 200 mm to 90 mm 73 140 mm to 90 mm 74 110 mm to 90 mm 75 90 mm to 90 mm 76 Construction of drinking water house connection with distribution mains (HDPE, AC, DI, PVC) including dismantling in all type of road, supply and carting of material (20 mm HDPE pipe PE-80/PN-16 from trench to outer wall/boundary wall, 15 mm GI pipe class-B average length 3 m, 15 mm GI elbow includingHDPE electrofusion shaddle for HDPE pipe and DI strap saddle for DI pipe shall be used.1 No. brass tap shall be fixed inside the house of consumer as per IS 8931 and 8934, All 20 mm GI union, 20 mm, 1 No. 15 mm brass ferrule and other GI fitting and specialsshall be according to IS 12183 & IS2065. , FTA & MTA and other compression fittings of 100% pure virgin (Georgefisher, kimplas) shall be provided. HDPE shaddle shall be fixed with electrofusion method.All fitting of water supply house connections shall be fixed them into trenches, fixing them in proper alignment and jointing and making hols in walls for crossing the GI pipe, fixing of GI pipe with minimum 3 hooks & repairing of hold after connection, necessary excavation for connection with temporary reinstatement of all type of road including supply of all machinery, T&P, labour etc. required for proper completion of the work as per directions of engineer-in-charge. For New pipe Line 77 For 90 mm to 110 mm dia 78 For 140 mm to 160 mm dia 79 For 200 mm to 250 mm dia 80 For 250 mm to 300 mm dia 81 For 350 mm to 500 mm dia 82 For Existing pipe Line 83 For 90 mm to 110 mm dia 84 For 140 mm to 160 mm dia 85 For 200 mm to 250 mm dia 86 For 250 mm to 300 mm dia 87 For 350 mm to 500 mm dia 88 Permanent re-instatement of following type of road surfaces after laying of pipe line (for New & Existing house connection work) including supply of all materials, labour, T&P etc. required for completion of work. It also includes necessary excavation required for preparation of trench for reinstatement of road, disposal of surplus unserviceable material, watering, ramming, cleaning of surface for proper completion of the work as per directions of engineer-in-charge. 89 Brick on edge with bricks (60 % New & 40% Old) laid dry, joints filled with local sand including preparation of base to proper slope and its ramming, spreading a layer of 10 cm depth of local sand over the subgrade and including supply of all materials, labour, T&P etc. required for proper complete of the work. 90 Re-instatement of bitumen road as per specification including supply of all materials, labour, T&P etc. required for proper completion of work. To achive the required quality of work, graded material in appropriate quantity shall be supplied by the contractor. This material shall be used in filling of trenches onlyafter succesfully testing of material with relevent IS code. Sample collection of GSB material, BM and SDBC will be done asrequired by engineer incharge. 91 Providing and laying design mix cement concrete 100 mm thick of M-20 grade, in roads, using cement content as per design mix, using coarse sand and graded stone aggregate of 20 mm nominal size in appropriate proportions as per approved & specified design criteria, mixing with weigh batcher, laying at site, spreading and mechanically compacting by using needle and surface vibrators, levelling to required slope / camber, finishing with required texture over 100 mm thick base of GSB. 92 Providing and laying of 80 mm thick M-30 grade C.C. rubber moulded (60% new and 40% old tiles) interlocking paver tiles over 30 mm thick fine sand bed and also including earth wotk in excavation in proper slope & camber including all materials, labour, T&P required for proper completion of work. 93 Repairing of leakages in existing pipe (HDPE, AC, DI, PVC) line including dismantling in all types of road, excavation of trench, bailing out of water repairing the joint, backfilling of earth and Permanent reinstatement of all types road in pipes of different dia including supply of all material, specials, machinery, T&P, labour etc. required for proper completion of the work as per directions of engineer-in-charge. 94 For 90 mm to 200 mm dia 95 For 250 mm to 500 mm dia 96 Supply and fixing of end cap (HDPE, AC, DI, PVC) & fixing of Sluice valve for dividing into separate zone including excavation of pit, bailing out of water, fixing the end cap and then again refilling the earth in the pit including supply of all materials, specials, machinery, T&P, labour etc. required for proper completion of the work as per directions of engineer-in-charge. 97 For 90 mm to 200 mm dia 98 For 250 mm to 500 mm dia 99 CONSTRUCTION OF PUMP HOUSE CUM CHLORONOME 4 Nos.Supply of all material T&P etc. required for construction of Pump House 04 Nos. as per typical drawing and design of department. The structural design of pump house shall be submitted by the contractor on the basis of safe bearing capacity of soil. The plinth level of Pump House shall be 60cm above from finished GL of the campus. The following criteria shall be taken in consideration for structural design of Pump House including campus cleaning, removal of debries, bush cutting and disposal within municipal limt and filling ogf earth if required as per direction of engineer in charge.Note - Plinth should be made above 60 cm above from nearest highest service / link road.Excavation of earth for foundation in ordinary soil (loam, clay or sand) including lift upto 1.5M and lead upto 50M including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches and plinth, disposal of surplus earth upto a distance to 50M from the center of the foundation trenches. 100 Concrete with cement, coarse sand and 40 mm nominal size approved stone ballast in proportion of 1:4:8 in foundations and plinth including supply of all materials, labour, T&P etc. required for proper completion of the work. 101 Ist class brick work in 1:6 cement & coarse sand mortar in foundation and plinth including supply of all materials, labour, T&P etc. required for proper completion of the work. 102 40 mm thick D.P.C. in cement concrete consisting of 1:2:4 cement, coarse sand and graded stone aggregate 12.5 mm nominal size(10-12.5 mm) and including water proofing(ISI Mark) compound in the proportion including supply of all materials, labour, T&P etc. required for proper completion of the work. 103 12 mm thick plaster in 1:4 cement and coarse sand mortar for plinth shall be done on both side of brick work inner side 15 cm below plinth and outside 15 cm below GL. 104 First Class brick work in 1:4 cement and coarse sand mortar in super structure including necessary cutting and moulding of bricks as required and also including supply of all materials, labour, T&P etc. required for proper completion of the work(thickness of wall not be less than one brick). 105 Supply and fixing of M.S. angle iron 40x40x5mm door chaukhat including supply and fixing of four hinges with one coat of red oxidised primer. 106 1.20 x 2.10 M1.00 x 2.10 M 107 Supply and fixing of the Z-section M.S. window with grill as per departmental type drawing including supply and fitting of handle, locking arrangement etc. with one coat of red oxidised primer. 108 Supply and fixing of cement jali 45x30 cm at 15 cm above floor level in the chloronome for proper ventilation. 109 Mild steel or iron in plain work such as reinforced concrete or reinforced brick work wrought to required shape as necessary including supply of all steel and its bending and binding with binding wire necessary over lapping as required etc. complete. 110 R.C.C. work (with use of C.C. mixer) in proportion of 1:1.5:3 cement, coarse sand and 20mm nominal size (10mm-1 part & 20 mm - 2 part) stone grit with proper finishing including supply of all materials, labour, T&P and Kachcha plaster on wooden plank shuttering or ply shuttering excluding cost of steel but including binding the same with 24 B.W.G. binding wire. 111 Lintels 112 Beam 113 Sun shades & Slab 114 Cement concrete with cement, coarse sand & 20 mm nominal size(10-20 mm) stone grit in proportion 1:2:4 including supply of all materials, labour, T&P etc., required for proper completion of the work, in bed block of girder, hold fast and girder fixing and in flooring of bypass chamber, window sills etc. 115 Supply and fixing in position rolled steel joist ISMB of 200mm x 100mm size and 3.40M long including supply of all labour, T&P etc. required for proper completion of the work. 116 150 mm thick local sand filling under floor including supply of local sand, filling, watering and ramming etc. completefor proper completion of the work. 117 40mm thick 1:2:4 plain cement concrete floor with cement, coarse sand and 20 mm nominal size(10-20 mm) stone grit laid in panel and finished with 3mm floating coat of neat cementincluding / over 75mm thick base concrete consisting of cement, coarse sand and stone ballast 40mm nominal size(20-40 mm) in proportion of 1:4:8 and removing all over lapping of mortar at the joints of the panels if any and giving them uniform finishing including supply of all materials, labour, T&P etc. required for proper completion of the work 118 12mm thick plaster above plinth in 1:6 cement and Banda(Ken)/ Hamirpur(Betva) sand over brick work, minimum thickness not to be less than 10mm including supply of all materials, labour, T&P etc. required for proper completion of the work. 119 6 mm thick plaster on ceiling, sunshades and projected slab of R.C.C. work in 1:4 cement and Banda/Hamirpur fine sand F.M. not less than 1.25 mm including supply of all materials, labour, T&P etc. complete for proper completion of the work. 120 20 mm thick plaster in dado or skirting with cement mortar in proportion of 1:2 cement and coarse sand with finishing of 3 mm thick floating coat of neat cement including supply of all materials, labour, T&P etc. required for completion of the work. 121 20mm wide drip course with cement mortar in proportion of 1:3 with cement and Banda/Hamirpur coarse sand. 122 Providing 45 cm wide and 25mm thick cc apron of 1:2:4 cement, coarse sand and 10-20mm stone gritover 75mm thick base concrete in 1:4:8 cement, coarse sand and 40mm nominal size(20mm-2 part & 40 mm-6 part) stone ballast with finishing of 3 mm thick floating coat of neat cement also including supply of all materials,labour,T&P etc. complete. 123 Construction of 100mm wide cc drain as per departmental drawing in proportion of 1:2:4 cement, coarse sand and 20 mm nominal(10 mm - 1 part & 20 mm - 3 part) stone grit over 100 mm base concrete in proportion of 1:4:8 cement, coarse sand and 40mm nominal(20 mm - 2 part & 40 mm - 6 part) stone ballast with finishing of 3 mm thick floating coat of neat cement also including supply of all materials,labour,T&P etc. complete. 124 Brick Coba :- (a)Providing & laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc. consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 Kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over the R.C.C. slab including adjointing walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5( 1 cement:5 coarse sand) admixed with water proofing compound conforming to IS:2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5(1 cement:5 coarse sand) admixed with water proofing compound conforming to IS:2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of juctions of walls and slabs (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS:2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortarof mix 1:4(1 cement : 4 coarse sand) admixed with water proofing compound conforming to IS:2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm squared 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operation to be done in order and as directed and specified by the Engineer-in-charge: With average thickness of 120 mm and minimum thickness at khurra as 65 mm 125 The outer surface of wall finish with two coat of weather coat- All Guard, Apex-Ultima (premium acrylic smooth exterior paint with silicon additive) with one coat of priming coat of exterior primer over smooth base of white cement based wall putty such as Birla, J.K. wall putty over the plastered wall surface to prepare the surface even and smooth including supply of all materials, labour, T&P etc. required for proper completion of the work. 126 The inner finish should be two coat of oil bound distemper Ist quality such as Bison distemper, tractor distemper with one coat of priming coat over smooth base of cement based wall putty such as Birla, J.K. wall putty over the plastered wall surface to prepare the surface even and smooth including supply of all materials, labour, T&P etc. required for proper completion of the work. 127 Supply and fixing of ISI marked waterproof flush door shutters of required size of 35 mm thick including heavy size steel fitting e.g. tower bolt, sliding bolt, handle etc., lab our, T&P etc.complete. 128 Supply and fixing of 4 mm thick glass panes in panel of Z-section window shutters including supply of M.S. clip and I.S.I. mark putty etc. as required for proper completion of the work. 129 Supply and fixing of rain water pipe P.V.C. 110mm 6 Kg/Cm2(2 Nos.) with bend and clamp etc. all complete. 130 Painting or varnishing of new iron work in small areas or new wood work with one coat of priming and two coats of synthetic enamel paint or varnish including supply of all materials, labour, T&P etc. required for proper completion of the work. 131 Provide 3mm thick floating coat of neat cement over the previously made plaster on by pass chamber & over plinth plaster etc. 132 Providing 15cm long 25 mm dia P.V.C. Pipe with cutting at ends and fixing the same with cement and coarse sand mortar in sunshades. 133 Supply and fixing 3 mm thick glass strips in floor and aprons panels in 1:3 cement and coarse sand mortar. 134 25x3mm 135 40x3mm 136 Disposal of waste water of by pass chamber through P.V.C. Pipe 160mm dia including supply of pipe, excavation & laying, T&P etc. complete. 137 Supply and fixing of 900 V-notch 4mm thick M.S plate with sharp edged and scale etc.complete as per direction of engineer incharge. 138 BUILDING WORK :-Excavation of earth for foundation in ordinary soil (loam, clay or sand) including lift upto 1.5M and lead upto 50M including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches and plinth, disposal of surplus earth upto a distance to 50M from the center of the foundation trenches. 139 Concrete with cement, coarse sand and 40 mm nominal size (20 mm-2 part & 40 mm - 6 part) approved stone ballast in proportion of 1:4:8 in foundations including supply of all materials, labour, T&P etc. required for proper completion of the work. 140 Ist class brick work in 1:6 cement &coarse sand mortar in foundation and plinth including supply of all materials, labour, T&P etc. required for proper completion of the work. 141 40 mm thick D.P.C. in cement concrete consisting of 1:2:4 cement, coarse sand and graded stone aggregate 12.5 mm nominal size(10-12.5 mm) and including water proofing(ISI Mark) compound in the proportion as specified by the manufacturer including supply of all materials, labour, T&P etc. required for proper completion of the work. 142 12 mm thick plaster in 1:4 cement and coarse sand mortar for plinth shall be done on both side of brick work inner side 15 cm below plinth and outside 15 cm below GL. 143 First Class brick work in 1:4 cement and coarse sand mortar in super structure including necessary cutting and moulding of bricks as required and also including supply of all materials, labour, T&P etc. required for proper completion of the work (thickness of wall not be less than one brick). 144 Supply and fixing of M.S. angle iron 40x40x5mm door chaukhat including supply and fixing of four hinges with one coat of red oxidised primer. 145 Supply and fix hold fast in doors and windows chaukhats 25cmx50mmx6mm flat iron including their cutting,moulding, welding to requirwed shape also including other materials such as nails and screws etc required in all aspect to complete the work. 146 Supply and fixing of the Z-section M.S. window with grill as per departmental type drawing including supply and fitting of handle, locking arrangement etc. with one coat of red oxidised primer. 147 Mild steel or iron in plain work such as reinforced concrete or reinforced brick work wrought to required shape as necessary including supply of all steel and its bending and binding with binding wire necessary over lapping as required etc. complete. 148 R.C.C. work (with use of C.C. mixer) in proportion of 1:1.5:3 cement, coarse sand and 20mm nominal size (10mm-1 part & 20 mm - 2 part) stone grit with proper finishing including supply of all materials, labour, T&P and Kachcha plaster on wooden plank shuttering or ply shuttering excluding cost of steel but including binding the same with 24 B.W.G. binding wire. 149 Footing 150 Column 151 Plinth Beam 152 Lintels 153 Sun-shades & Slab 154 Stairs 155 Sand filling under floor including supply of local sand, filling, watering and ramming etc. completefor proper completion of the work. 156 25 mm thick 1:2:4 plain cement concrete floor with cement, coarse sand and 20 mm nominal size(10-20 mm) stone grit laid in panel and finished with 3mm floating coat of neat cementincluding 75mm thick base concrete consisting of cement, coarse sand and stone ballast 40mm nominal size(20-40 mm) in proportion of 1:4:8 and removing all over lapping of mortar at the joints of the panels if any and giving them uniform finishing including fixing of glass strip at desired intervals, supply of all materials, labour, T&P etc. required for proper completion of the work 157 40 mm thick 1:2:4 plain cement concrete floor with cement, coarse sand and 20 mm nominal size(10-20 mm) stone grit laid in panel and finished with 3mm floating coat of neat cementincluding 75mm thick base concrete consisting of cement, coarse sand and first class brick ballast 40mm nominal size (20-40 mm) in proportion of 1:4:8 and removing all over lapping of mortar at the joints of the panels if any and giving them uniform finishing including fixing of glass strip at desired intervals, supply of all materials, labour, T&P etc. required for proper completion of the work. 158 Supply and fixing of ISI marked water proof flush door shutters of 40 mm thickincluding all labour, T&P etc. complete but excluding painting and including ISI marked oxidized iron fitting e.g. tower bolt, sliding bolt, handle etc. complete as per direction. 159 Supply and fixing of oxidized iron fittings of approved make for doors and window. 160 12mm thick plaster above plinth with cement, mortar in proportion of 1:6 cement and Banda(Ken)/ Hamirpur(Betva) sand over brick work, minimum thickness not to be less than 10mm including supply of all materials, labour, T&P etc. required for proper completion of the work. 161 20 mm thick plaster in dado or skirting with cement mortar in proportion of 1:2 cement and coarse sand with finishing 3 mm thick floating coat of neat cement including supply of all materials, labour, T&P etc. required for completion of the work. 162 Brick Coba :- (a)Providing & laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc. consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 Kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over the R.C.C. slab including adjointing walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5( 1 cement:5 coarse sand) admixed with water proofing compound conforming to IS:2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5(1 cement:5 coarse sand) admixed with water proofing compound conforming to IS:2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of juctions of walls and slabs (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS:2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortarof mix 1:4(1 cement : 4 coarse sand) admixed with water proofing compound conforming to IS:2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm squared 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operation to be done in order and as directed and specified by the Engineer-in-charge: With average thickness of 120 mm and minimum thickness at khurra as 65 mm 163 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 164 Providing and fixing 1st quality vetrified floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting / dados (height 150 mm) over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. 165 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 166 200x300 mm ceramic tiles over base with 12 mm thick 1:3 cement and coarse sand mortar in kitchen upto 60 cm high above platform, W.C. wall - 120 cm high and bathroom wall 1.80 m high including supply of all materials, labour, T&P etc. required for proper completion of the work. 167 Kitchen platform 18 mm thick polished kota stone over 12 mm thick 1:3 cement and coarse sand mortar including supply of all materials, labour, T&P etc. required for proper completion of work. 168 W.C. and bathroom floor 300x300 mm Antiskid/mattfinished ceramic tiles over 20 mm thick 1:4 cement & coarse sand mortar including supply of all material, labour, T&P etc. required for proper completion of the work. 169 Providing 45 cm wide and 25mm thick P.C.C apron in 1:2:4 cement, coarse sand and 10-20mm stone gritover 75mm thick base concrete in 1:4:8 cement, coarse sand and 20 to 40mm gauge stone ballast with finishing coat of neat cement including fixing of glass strips at desired intervals including supply of all materials,labour,T&P etc. complete. 170 Supply and fixing 3 mm thick glass strips in floor and aprons panels in 1:3 cement and coarse sand mortar. 171 25x3mm 172 40x3mm 173 The outer surface of wall finish with two coat of weather coat-All Guard, Apex-Ultima (premium acrylic smooth exterior paint with silicon additive) with one coat of priming coat of exterior primer over smooth base of white cement based wall putty such asBirla, J.K. wall putty over the plastered wall surface to prepare the surface even and smooth including supply of all materials, labour, T&P etc. required for proper completion of the work. 174 The inner finish should be two coat of oil bound distemper Ist quality such as Bison distemper, tractor distemper with one coat of priming coat over smooth base of cement based wall putty such as Birla, J.K. wall putty over the plastered wall surface to prepare the surface even and smooth including supply of all materials, labour, T&P etc. required for proper completion of the work. 175 Supply and fixing of 4 mm thick glass panes in panel of Z-section window shutters including supply of M.S. clip and I.S.I. mark putty etc. as required for proper completion of the work. 176 Construction of 100mm dia semi circular C.C. drain as per departmental drawing in proportion of 1:2:4 cement, coarse sand and 20 mm nominal(10 mm - 1 part & 20 mm - 3 part) stone grit over 100 mm base concrete in proportion of 1:4:8 cement, coarse sand and 40mm nominal(20 mm - 2 part & 40 mm - 6 part) stone ballast with finishing of 3 mm thick floating coat of neat cement also including supply of all materials, labour, T&P etc. complete. 177 Painting and varnishing over new iron work or new wooden work with one coat of primer and two coats of approved paints or varnish including supply of all materials, labour, T&P etc. required for proper completion of work. 178 Supply and fixing of 100 mm dia PVC pipe rain water down pipe with clamp 179 Water supply & sanitary fittings Water supply & sanitary fittings Orissa Pan 580 mm with low level P.V.C. cistern (ISI marked) one W.H.B. 450x300 mm size stainless steel kitchen sink without drain board, one stainless steel soap tray with W.H.B. including glazed tiles in 600 m height one looking mirror with W.H.B., 500 litre P.V.C. storage tank etc. and also as per direction of Engineer-in-charge.Electrical provisionAll wiring, Fan hook in room & verandah, aquaguard or water purifier point in kitchen, power point in kitchen & bed room, computer and T.V./cable point in room, 16 Am point at a suitable place as per direction, exhaust point in kitchen, copper wiring in conduit, C.F.L. in all places of bulbs etc., 08 Nos. Flood light for campus lightning and also as per direction of Engineer-in-charge. Internal electrificaton, water supply and sanitary fittings including supply of all materials, labour, T&P etc. Complete. 180 Construction of septic tank and soak pit including all type of earth/soil excavation with supply of all machinery, T&P, labour etc. required for proper completion of the work as per directions of engineer-in-charge (for Staff Quarter only) 181 Construction of septic tank :- Septic tank shall be of first class brick work in 1:4 cement mortar the foundation and floor shall be of 1:3:6 cement concrete. Inside of septic tank shall be finished with 12 mm cement plaster and floor shall be finished with 20 mm cement plaster with 1:3 mortar mixed with standard water proofing compound. Upper and lower portion of soak-pit shalk be of second class brick work in 1:6 cement mortar and middle portion shall be of dray brickwork. Roof covering slabs and baffle wall shal be of precast R.C.C. The length of the connecting pipe from latrine seat including all type of earth/soil excavation with supply of all machinery, T&P, labour etc. required for proper completion of the work as per directions of engineer-in-charge. 182 Providing and laying design mix cement concrete 100 mm thick of M-20 grade, in roads, using cement content as per design mix, using coarse sand and graded stone aggregate of 20 mm nominal size in appropriate proportions as per approved & specified design criteria, mixing with weigh batcher, laying at site, spreading and mechanically compacting by using needle and surface vibrators, levelling to required slope / camber, finishing with required texture over 100 mm thick base of GSB. 183 Supply & Laying of 80 mm thick cement concrete paver block of M-30 grade with approved colour, design & pattern inter locking tiles over 30 mm thick fine sand bed over 150mm thick GSB and also including earth wotk in excavation in proper slope & camber, brick work for side alignment including all materials, labour, T&P required for proper completion of work as per direction of Engineer in charge. 184 Horticulture, plantation, Land scaping, beautification, internal path way at water works compound including supply of all material, labour T&P etc. as per approval and direction of engineer in charge 185 Development work :-Construction of boundary wall, Gate with piller, site development, approach road (Zone 6 and 9) & repairing of boundary wall Gate with piller, site development, approach road (Zone 1, 2, 3, 4, 5, 7 and 8)campus cleaning, removal of debries, bush cutting and disposal within municipal limt and filling ogf earth if required as per direction of engineer in charge.Note - Plinth should be made above 60 cm from nearest highest service / link road.Excavation of earth for foundation in ordinary soil (loam, clay or sand) including lift upto 1.5M and lead upto 50 M including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches and plinth, disposal of surplus earth upto a distance to 50M from the center of the foundation trenches. 186 Concrete with cement, coarse sand and 40 mm nominal size (20 mm-2 part & 40 mm - 6 part) approved stone ballast in proportion of 1:4:8 in foundations including supply of all materials, labour, T&P etc. required for proper completion of the work. 187 Ist class brick work in 1:6 cement & coarse sand mortar in foundation and plinth including supply of all materials, labour, T&P etc. required for proper completion of the work. 188 20 mm thick D.P.C. in cement concrete consisting of 1:2:4 cement, coarse sand and graded stone aggregate 12.5 mm nominal size(10-12.5 mm) and including water proofing(ISI Mark) compound in the proportion as specified by the manufacturer including supply of all materials, labour, T&P etc. required for proper completion of the work. 189 12 mm thick plaster in 1:4 with cement and coarse sand mortar for plinth shall be done on both side of brick work upto 15 cm below GL. 190 First Class brick work in 1:4 cement and coarse sand mortar in super structure including necessary cutting and moulding of bricks as required and also including supply of all materials, labour, T&P etc. required for proper completion of the work(thickness of wall not be less than one brick). 191 C.C. coping on boundry wall & RCC Piller in 1:2:4 cement, coarse sand and stone grit (10-12.5 mm) including supply of all material, cost of centering, shuttering with extra labour, T&P etc. complete required for proper completion of work. 192 12mm thick plaster with cement mortar in proportion of 1:6 consisting of cement and Banda(Ken)/Hamirpur(Betava) sand over brick work including supply of all materials, labour, T&P etc. required for proper completion of the work. 193 Making groves 15 mm wide on wall plaster as per drawing including supply of all materials, labour, T&P etc. required for proper completion of the work. 194 Supply and fixing of barbed iron wire fencing to post in four rows including supply of all materials, labour, T&P etc. required for proper completion of the work as per direction of engineer in charge. 195 M.S. angle iron (50x50x6 mm) for barbed wire fencing and 2 meter distance including supply of all materials, labour, T&P etc. required for proper completion of the work as per direction of engineer in charge. 196 Concrete with cement, coarse sand and 20 mm approved stone ballast in proportion of 4:2:1 in including supply of all materials, labour, T&P etc. required for fixing M.S. Iron angle proper completion of the work. 197 Raised pointing with cement mortar 1:4 consisting or cement and local sand on brick work including supply of all materials, labour, T&P etc. required for proper completion of the work. 198 White washing in three coats including supply of all materials labour, T&P etc required for proper completion of work. 199 The outer surface of wall finish with two coat of weather coat-All Guard, Apex-Ultima(Premium Acrylic Smooth Exterior Paint with Silicon Additive) with one coat of priming coat of exterior primer over smooth base of white cement based wall putty such asBirla, J.K. wall Putty over the plastered wall surface to prepare the surface even and smooth including supply of all materials, labour, T&P etc. required for proper completion of the work. 200 Supply and fixing of M.S. gate with RCC piler as per departmental design & drawing with ncessary hold fast, bush and ball bearing, sliding bolt and locking arrangement, painting etc. including supply of all material, labour, T&P etc. required for proper completion of the work for Water works campus (3.60 M wide main gate) 201 Supply and fixing of M.S. gate with RCC piler as per departmental design & drawing with ncessary hold fast, bush and ball bearing, sliding bolt and locking arrangement, painting etc. including supply of all material, labour, T&P etc. required for proper completion of the work for Water works campus (1.20 M wide wicket gate) 202 Supply & Laying of 80 mm thick cement concrete paver block of M-30 grade with approved colour, design & pattern inter locking tiles over 30 mm thick fine sand bed over 150mm thick GSB and also including earth wotk in excavation in proper slope & camber, brick work for side alignment including all materials, labour, T&P required for proper completion of work as per direction of Engineer in charge. 203 Construction of 300 mm wide and 300 mm deep brick drain inside the water works campus including supply of all materials, labour, T&P etc required for proper completion of the work 204 Providing and fixing of lighting arrangement in campus complete in all respect including supply of all material, labour T&P etc. as per approval and direction of engineer in charge 205 Horticulture, plantation, Land scaping, beautification, internal path way at water works compound including supply of all material, labour T&P etc. as per approval and direction of engineer in charge 206 Construction of Artificial Recharging of Ground water hrough roof top rain water of pump house, bypass chamber’s water & overflow of O.H.T. supplying of all material, pipes, grates, etc. complete in all respect 207 Filling of earth in water works campus and TW/pump house campus including supply of carted earth including loading, unloding, levelling, dressing and ramming of the earth tc complete in all respect.Earth filling in the campus shall be done Contour survey of campus and prior written necessary permission of Engineer in charge. 208 Supply of following items as per ditrection of engineer in charge 209 Office table (Godrej Make) (6x4 fit) with shelf and Glass 210 Office table (Godrej Make) (8x4 fit) with shelf and Glass 211 Computer table (Godrej Make) (4x3 fit) with Shelf 212 Revolving Chair (Godrej Make) 213 Office chair (Godrej Make) 214 Computer chair Revolving (Godrej Make) 215 Almirah (Godrej Make) 216 Almirah Glass rak (Godrej Make) 217 Split AC (1.5 tonne) Five star (Voltas, Hitachi, Blue star Make) with Stablizer 218 Desktop (Hp, Dell Make) with Color Laser Printer (Hp Make) (i5 processor) 219 Xerox machine wifi (HP, Canon, Samsung Make) 220 Color Printer wifi (HP Make) 221 Repairing work of existing pump house - 25 Nos. & Local Control Station room - 01 No.Ist class brick work in 1:6 cement &coarse sand mortar in foundation and plinth including supply of all materials, labour, T&P etc. required for proper completion of the work. 222 Dismantling existing plaster over damage/cracked surface with stacking / proper disposal opf chiseld plaster including supply of all materials, labour T&P etc. required for proper completion of the work as directed by the engineer in charge. 223 Racking of joints of brick mansonry in wall in exposed surface to poperly prepare surface for new plaster work including supply of all materials, labour T&P etc. required for proper completion of the work. 224 12 mm thick plaster with cement & coarse sand mortar in 1:6 over brick work minimum thickness not to be less than 12 mm finished with 3 mm floting coating of neat cement including supply of all materials, labour T&P etc. required for proper completion of the work 225 Repair for electric fitting 226 Reparing of floor in PCC 1:2:4 227 First Class brick work in 1:4 cement and coarse sand mortar in super structure including necessary cutting and moulding of bricks as required and also including supply of all materials, labour, T&P etc. required for proper completion of the work (thickness of wall not be less than one brick). 228 Repairing of 25 mm thick PCC floor laid over base concrete consisting of cement, local sand and 40mm gauge first class brick ballast in the proportion of 1:4:8. For construction of apron 0.6m wide. 229 Supply and fixing of flush door including supply and fixing of all assessories, all materials, labour T&P etc. required for proper completion of the work as per direction of engineer in charge. 230 Supply and fix angle iron door chaukhat of size 50mm x 50mm x 6 mm including supply of all materials, labour T&P etc. required for proper completion of the work (Door & Window Frame) 231 Door Frame (02 Nos.) 232 Window Frame (04 Nos.) 233 Supply and fixing of the M.S. window with grill as per departmental drawing including supply and fixing of handle, locking arrangement etc. with one coat of red oxidised primer. 234 11.5 cm string or drip-coarse in 1:6 cement and local sand mortor 235 Painting or varnishing new iron work in small areas or new wood work with one priming coat and one coat of approved paints or varnish including supply of all materials labour, T&P etc required for proper completion of work. 236 White washing in three coats including supply of all materials labour, T&P etc required for proper completion of work. 237 The inner finish should be two coat of oil bound distamper Ist quality such as Bison distemper, tractor distemper with one coat of priming coat over smooth base of cement based wall putty such as Birla, J.K. wall putty over the plastered wall surface to prepare the surface even and smooth including supply of all materials, labour, T&P etc. required for proper completion of the work. 238 The outer surface of wall with two coat of weather coat-All guard, Apex- Ultima (Premium Acrylic smooth Exterior paint with silicon Additive) with one coat of primer coat exterior primer over smooth base of white cement based wall putty such as Birla, J.K. wall putty over the plastered wall surface to prepare the surface even and smooth including supply of all materials, labour, T&P etc. required for proper completion of the work. 239 Supply and fixing 4 mm thick plain glass panes in panel of Z-section window shutter including supply of M.S. Clip and I.S.I. Mark putty etc as required for proper completion of work. 240 Supply and fixing of 100 mm dia PVC pipe rain water down pipe with clamp 241 Supply & fixing of forciling for LCS room including supply and fixing of all assessories, all materials, Paits, labour T&P etc. required for proper completion of the work as per direction of engineer in charge. 242 Repairing for electric fittings, wiring for LCS room including supply and fixing of all assessories, all materials, labour T&P etc. required for proper completion of the work as per direction of engineer in charge. 243 Repairing work of existing Staff Quarter (1 Set)First Class brick work in 1:4 cement and coarse sand mortar in super structure including necessary cutting and moulding of bricks as required and also including supply of all materials, labour, T&P etc. required for proper completion of the work (thickness of wall not be less than one brick). 244 12 mm thick plaster with cement & coarse sand mortar in 1:6 over brick work minimum thickness not to be less than 12 mm finished with 3 mm floting coating of neat cement including supply of all materials, labour T&P etc. required for proper completion of the work 245 Scraping old color washing and preparing the surface by removing loos material etc. including all labour and T&P ete complete 246 Repairing of 40 mm thick over base concrete consisting of cement, local sand and 40 mm gauge first class brick ballast in the proportion of 1:4:8. For construction of apron 0.6 m wide 247 White washing in three coats including supply of all materials labour, T&P etc required for proper completion of work. 248 The inner finish should be two coat of oil bound distamper Ist quality such as Bison distemper, tractor distemper with one coat of priming coat over smooth base of cement based wall putty such as Birla, J.K. wall putty over the plastered wall surface to prepare the surface even and smooth including supply of all materials, labour, T&P etc. required for proper completion of the work. 249 The outer surface of wall with two coat of weather coat-All guard, Apex- Ultima (Premium Acrylic smooth Exterior paint with silicon Additive) with one coat of primer coat exterior primer over smooth base of white cement based wall putty such as Birla, J.K. wall putty over the plastered wall surface to prepare the surface even and smooth including supply of all materials, labour, T&P etc. required for proper completion of the work. 250 Supply and fix angle iron door chaukhat of size 50mm x 50mm x 6 mm including supply of all materials, labour T&P etc. required for proper completion of the work (Door & Window Frame) 251 Door Frame (02 Nos.) 252 Window Frame (04 Nos.) 253 Supply and fixing of the M.S. window with grill as per departmental drawing including supply and fixing of handle, locking arrangement etc. with one coat of red oxidised primer. 254 Supply and fixing of flush door including supply and fixing of all assessories, all materials, labour T&P etc. required for proper completion of the work as per direction of engineer in charge. 255 Painting or varnishing new iron work in small areas or new wood work with one priming coat and one coat of approved paints or varnish including supply of all materials labour, T&P etc required for proper completion of work. 256 Supply and fixing 4 mm thick plain glass panes in panel of Z-section window shutter including supply of M.S. Clip and I.S.I. Mark putty etc as required for proper completion of work. 257 Repair for electric fitting 258 Repair for sanitation work 259 Supply and fixing of 100 mm dia PVC pipe rain water down pipe with clamp 260 Repairing work of Existing Clear water reservoir cum pump house (500 KL at Zone 5 & 400 KL at Zone 8)Cleaning of Surface area of CWR including supply of all materials, labour, T&P etc. required for proper completion of the work.complete asper direction of Engineer-in-charge. 261 Providing and applying one coat of slurry of hydrophilic in nature for waterproofing treatment of internal surface of Tank. 262 Repairs of Tank wall, water tighteing work including all labour, material etc required for completion of work. 263 Dismantling existing plaster over damage/cracked surface including supply of all materials, labour T&P etc. required for proper completion of the work. 264 Stacking/proper disposal of chiseld plaster as directed by the Engineer- in-charge 265 12 mm thick plaster with cement & coarse sand mortar in 1:6 over brick work minimum thickness not to be less than 12 mm finished with 3 mm floting coating of neat cement including supply of all materials, labour T&P etc. required for proper completion of the work 266 Repairs of cracks on concret surface of tank including all labour, material extraholding etc required for completion of work. 267 Ist class brick work in 1:6 cement &coarse sand mortar in foundation and plinth including supply of all materials, labour, T&P etc. required for proper completion of the work. 268 Racking of joints of brick mansonry in wall in exposed surface to poperly prepare surface for new plaster work including supply of all materials, labour T&P etc. required for proper completion of the work. 269 Repair for electric fitting 270 Reparing of floor in PCC 1:2:4 271 First Class brick work in 1:4 cement and coarse sand mortar in super structure including necessary cutting and moulding of bricks as required and also including supply of all materials, labour, T&P etc. required for proper completion of the work (thickness of wall not be less than one brick). 272 Repairing of 25 mm thick PCC floor laid over base concrete consisting of cement, local sand and 40mm gauge first class brick ballast in the proportion of 1:4:8. For construction of apron 0.6m wide. 273 Supply and fixing of flush door including supply and fixing of all assessories, all materials, labour T&P etc. required for proper completion of the work as per direction of engineer in charge. 274 Supply and fix angle iron door chaukhat of size 50mm x 50mm x 6 mm including supply of all materials, labour T&P etc. required for proper completion of the work (Door & Window Frame) 275 Door Frame (02 Nos.) 276 Window Frame (04 Nos.) 277 Supply and fixing of the M.S. window with grill as per departmental drawing including supply and fixing of handle, locking arrangement etc. with one coat of red oxidised primer. 278 11.5 cm string or drip-coarse in 1:6 cement and local sand mortor 279 Painting or varnishing new iron work in small areas or new wood work with one priming coat and one coat of approved paints or varnish including supply of all materials labour, T&P etc required for proper completion of work. 280 White washing in three coats including supply of all materials labour, T&P etc required for proper completion of work. 281 The inner finish should be two coat of oil bound distamper Ist quality such as Bison distemper, tractor distemper with one coat of priming coat over smooth base of cement based wall putty such as Birla, J.K. wall putty over the plastered wall surface to prepare the surface even and smooth including supply of all materials, labour, T&P etc. required for proper completion of the work. 282 The outer surface of wall with two coat of weather coat-All guard, Apex- Ultima (Premium Acrylic smooth Exterior paint with silicon Additive) with one coat of primer coat exterior primer over smooth base of white cement based wall putty such as Birla, J.K. wall putty over the plastered wall surface to prepare the surface even and smooth including supply of all materials, labour, T&P etc. required for proper completion of the work. 283 Supply and fixing 4 mm thick plain glass panes in panel of Z-section window shutter including supply of M.S. Clip and I.S.I. Mark putty etc as required for proper completion of work. 284 Supply and fixing of 100 mm dia PVC pipe rain water down pipe with clamp 285 Repairing work of existing Over Head Tank (Zone - 1, 2, 3, 4, 5, 7 & 8)Supply and fixing on lightening Conductor on O.H.T. with proper arrangement and alignment including all labour and T&P etc. complete. The lightening conductor consisting of an elevation rod, down conductor and earth plate shall confrom with the standars as required by the Electircal Inspector of U.P from time to time, Any amendment, addition etc. suggested or required by the Electircal Inspector shall be carried out including supply of all materials, labour T&P etc. required for proper completion of the work as per direction of Engineer-In-Charge. 286 Supply and fixing of water level indicator with suitable arrangement as per latest I.S. code including supply of all materials, labour T&P etc. required for proper completion of the work as per direction of Engineer-In-Charge. 287 The outer surface of wall with two coat of weather coat-All guard, Apex- Ultima (Premium Acrylic smooth Exterior paint with silicon Additive) with one coat of primer coat exterior primer over smooth base of white cement based wall putty such as Birla, J.K. wall putty over the plastered wall surface to prepare the surface even and smooth including supply of all materials, labour, T&P etc. required for proper completion of the work. 288 Repairs of O.H.T. wall, water tighteing workincluding supply of all materials, labour T&P etc. required for proper completion of the work as per direction of Engineer-In-Charge. 289 Repairs of cracks on concret surface of OHT (Brase, Column, Bottom dom, top Dom etc complete) by guniting methodincluding supply of all materials, labour T&P etc. required for proper completion of the work as per direction of Engineer-In-Charge. 290 Repairs & Replacement of OHT pipes & Specials including supply of all materials, labour T&P etc. required for proper completion of the work as per direction of Engineer-In-Charge. 291 Repairs & Replacement of Valves & carting including supply of all materials, labour T&P etc. required for proper completion of the work as per direction of Engineer-In-Charge. 292 Dismentling & reconstruction (including raising of flore of OHTincluding supply of all materials, labour T&P etc. required for proper completion of the work as per direction of Engineer-In-Charge. 293 Replacment of both M.S. Ladder (inner & outer) & MS cover on top dome including supply of all materials, labour T&P etc. required for proper completion of the work as per direction of Engineer-In-Charge. 294 Supply & fixing of medium class G.I. pipe in free roof on stair case, balconey and top domeincluding supply of all materials, labour T&P etc. required for proper completion of the work as per direction of Engineer-In-Charge. 295 Supply & fixing of M.S. safty gate on stair case including supply of all materials, labour T&P etc. required for proper completion of the work as per direction of Engineer-In-Charge. 296 Net on top dome wentincluding supply of all materials, labour T&P etc. required for proper completion of the work as per direction of Engineer-In-Charge. 297 B - E&M worksConstruction of5 Nos Tubewell (1200 LPM )TRANSPORTATION 298 RIG MACHIN:-Transportation of rig machineincluding Loading , unloading, Erection, Dismantling & labour etc complete in all respect . 299 AIR COMPRESSOR:-Transportation of 350 psi compressor including Loading , unloading, Erection, Dismantling & labour etc complete in all respect . 300 O.P. UNIT :-Transportation of 3 cusec op unit including Loading , unloading, Erection, Dismantling & labour etc complete in all respect . 301 TUBE WELL ASSEMBLY :-Transportation of TUBE WELL ASSEMBLYincluding Loading , unloading with labour etc complete in all respect . 302 (DRILLING BORE) As per IS 2800 (Part I & II) 303 Barricading 304 Logging of Bore 305 Drilling of 600mm dia bore from G.L. to 60m BGL. 306 Drilling of 500mm dia bore from 60m BGL to 100m BGL. 307 Drilling of 500mm dia bore from 100m BGL to180m BGL. 308 LOWERING OF TUBE WELL ASSEMBLY AND SHROUDING OF T.W. BY GRAVEL-Lowering of 300mm X 200mm dia tube well assembly in bore hole and shrouding of pea gravel between annular space ofbore hole and T.W. assembly from G.L. to 160m BGL. 309 Lowering of 300mm dia MSERW 7.1mm thick plain pipe from GL to 54 m BGL. 310 Lowering of 200mm dia MSERW plain/slotted pipe 7.1mm thick from 54 m BGL to 100m BGL. 311 Lowering of 200mm dia MSERW plain/slotted pipe 7.1mm thick from 100m BGL to 160m BGL. 312 TUBE WELL: ASSEMBLY MATERIALS(As per IS 4270, IS 8110) :- 313 300mm dia size MSERW housing pipe 7.1mm thick including with 1 no 300 X200mm dia M.S reducer 16mm thick, 1 noM.S. well cap 12mm thick , 11 no M.S. ring 150X12mm thick, M.S.clamp ,T.W. Support (I Section) etc comp in all respect . 314 200mm dia MSERW 7.1mm thick plain /slotted pipe including with 30 no M.S ring 150X12mmthick , 1 noM.S. bail plug , 20 no center guide etc comp in all respect. 315 PEA-GRAVEL (As per IS 4097) :-1.60mm to 4.80mm size pea-gravel of Lalkuwan quarry duly screened, washed and proper stackingat site. 316 Development of tube well by 350 PSI air compressor 317 Development of tube well by 350 PSI air compressor 318 Cutting of T.W. cover by gas cutter, re-welding of T.W. cover by Electric welding after complete development of work. 319 Development of tube well by 3 cusec O.P. Unit 320 Cutting of housing cover by gas cutter 321 Development of tube well by 3 cusec O.P. Unit. 322 Re-welding of Tube well cover by Electric welding 323 Watch & Ward during construction period. 324 TEST:-Chemical and bacteriological test. 325 Pumping plant with piping and valves ( 1200 LPM) for 3 Nos T/W 326 SITC with following1.Clear water submersible pump complete with electric motorcapable to operate on 380/420 volts 3 phase 50 Hz A.C. for 1200 LPM. 20 Mtr. Head and 10 H.P.(bothe tentative)- 1SetMAIN PIPING AND VALVES:-2.1-150MM dia 5.4 mm thick M.S. column pipe with both end flanged and groove for passing submersible cable in each length in 3.0m long 24 m with 1m long top pipe with cap (Dumdum) and sealing ring.etc2.2:-CI-D/F 90 Degree bend of size 150 mm dia -1No2.3:- CI-A/F Tee of size 150 mm dia -1No2.4:-M.S. distance piece of 150 mm dia 1.00m long 1 Nos. and 1.5m long 2 No.-3no2.5:-M.S. enlarger/reducer of suitable size.-1No2.6:-Reflex Valve 150 mm dia P.N. rating 1.0 Having following specification confirming (as per IS-14846-2000)-1No2.7:-Other necessary fitting for gauges, control cock, Air hand pump steel airline 40m etc.-1Set3:-Tools and Spanners with Pipe Wrench etc.-1Set4:-tones capacity 4.5 m lift, spur geared chain pulley block Indef make P Type-1No5:-9 inch size pump protection ring -1No6:-Miscellaneous items-1No7:-Painting of pumping plant materials-1job8:-Erection of pumping plant and Power wiring & earthing and other civil works.-1job9:-Commissioning & testing of pumping plant.-1job10:-On account ofwatch & ward during Pump Installation -1job 327 Spare column pipe heavy duty 150 mm Size 328 Internal electrification of pump house and chlorinating room with wiring point for light with 1.0mm sq. P.V.C. insulated multi strand copper conductor cable in heavy gauge rigid P.V.C. conduit pipe on surface complete 14 S.W.G. copper earth continuously wire piano type switch and ceiling rose/angle batton holder on 3 mm. thichphenolic laminated back ligh sheet etc. complete in all respect as per I.E. rule including luminaries with 15 amp. Switch fuse unit. 329 SCADA compatable chlorinating system 330 SITC of servo Stabilizer 10 KVA or suitable capacity 331 Sluice valves with motor operated actuator valves of size 150 mm 332 CE/UL Certified electromagnetic flowmeter of size 150mm 333 Soft starter 7.5 KW or suitable capacity 334 CE/UL Certified hydrostatic type sub soil watel level transmitter for T/W 335 Complete cabling of tubewell including all power & control cable of all equipment at pumphouse and OHT 336 CE/UL Certified Pressure transmitter 337 Pumping plant with piping and valves ( 1200 LPM) for 2 Nos T/W 338 SITC with following1.Clear water submersible pump complete with electric motorcapable to operate on 380/420 volts 3 phase 50 Hz A.C. for 1200 LPM. 46 Mtr. Head and 25 H.P.(bothe tentative)- 1SetMAIN PIPING AND VALVES:-2.1-150MM dia 5.4 mm thick M.S. column pipe with both end flanged and groove for passing submersible cable in each length in 3.0m long 24 m with 1m long top pipe with cap (Dumdum) and sealing ring.etc2.2:-CI-D/F 90 Degree bend of size 150 mm dia -1No2.3:- CI-A/F Tee of size 150 mm dia -1No2.4:-M.S. distance piece of 150 mm dia 1.00m long 1 Nos. and 1.5m long 2 No.-3no2.5:-M.S. enlarger/reducer of suitable size.-1No2.6:-Reflex Valve 150 mm dia P.N. rating 1.0 Having following specification confirming (as per IS-14846-2000)-1No2.7:-Other necessary fitting for gauges, control cock, Air hand pump steel airline 40m etc.-1Set3:-Tools and Spanners with Pipe Wrench etc.-1Set4:-tones capacity 4.5 m lift, spur geared chain pulley block Indef make P Type-1No5:-9 inch size pump protection ring -1No6:-Miscellaneous items-1No7:-Painting of pumping plant materials-1job8:-Erection of pumping plant and Power wiring & earthing and other civil works.-1job9:-Commissioning & testing of pumping plant.-1job10:-On account ofwatch & ward during Pump Installation -1job 339 Spare column pipe heavy duty 150 mm Size 340 Internal electrification of pump house and chlorinating room with wiring point for light with 1.0mm sq. P.V.C. insulated multi strand copper conductor cable in heavy gauge rigid P.V.C. conduit pipe on surface complete 14 S.W.G. copper earth continuously wire piano type switch and ceiling rose/angle batton holder on 3 mm. thichphenolic laminated back ligh sheet etc. complete in all respect as per I.E. rule including luminaries with 15 amp. Switch fuse unit. 341 SCADA compatable chlorinating system 342 SITC of servo Stabilizer 25 KVA or suitable capacity 343 Sluice valves with motor operated actuator valves of size 150 mm 344 CE/UL Certified electromagnetic flowmeter of size 150mm 345 Soft starter 22 KW or suitable capacity 346 CE/UL Certified hydrostatic type sub soil watel level transmitter for T/W 347 Complete cabling of tubewell including all power & control cable of all equipment at pumphouse and OHT 348 CE/UL Certified Pressure transmitter 349 Pumping plant for zps (zone-6) 350 PUMPING PLANTS:Supply of 3000 LPM at 33 mtrs. Head Synchrous speed1500 RPM Water Lubricant VT Pump with squirrel cage induction motor 40 HP suitable for above pump with TEFC enclosure including base plate along with coupling, coupling guard, foundation, bolts, Etc in all respect. 351 MAIN PIPING AND VALVES 352 D.I. Reflux valve 200 mm dia . 353 200 mm dia Sluice valve with actuater suitable for SCADA operation. 354 Common Header (for all pumps) 355 D.I. D/F Distance piece 250mm dia 0.5 mtr. Long 356 D.I. D/F Distance piece 250 mm dia 1 mtr. long 357 D.I. D/F Distance piece 250 mm dia 1.5 mtr. Long 358 D.I. D/F Distance piece 250 mm dia 2 mtr. Long 359 D.I. D/F Distance piece 250 mm dia 3 mtr. long. 360 D.I. D/F 900 bend 250 mm dia 361 D.I. Tee 250 x 200 x 250mm Tee A/F 362 Sluice valve 250 mm dia with actuater suitable to SCADA operation 363 DI D/FReflux valve 250 mm dia 364 Bye Pass Arrangement:- 365 A/F Tee 250x250x250 mm dia 366 Sluice valve 250mm dia with actuater suitable to SCADA operation 367 Dismantling joints for Commmon Header and Flowmeter for 250 mm dia 368 CE/UL Certified Electromagnetic FLOW METER:250 mm dia size 369 Electrical Items 370 Supply of 3 core 25 sq. mm. unarmoured Copper conductor cable from panel to starter and starter to respective motors with lugs etc. 371 Supply of 3.5 core 95 sq. mm. Aluminium armoured cable from LT Control Panel to Motor control panel. 372 MOTOR CONTROL PANNEL :-Supply of M.S. Fabricated Dust and Vermin Proof, Cubical Type, Floor Mounted Control Panel compatible to SCADA with RS485 Port consisting including all necessary equipments and protection devices as following :-INCOMING :-1 No. 200 Amp. M.C.C.B. motorizes & microprocessor based.OUTGOING :- (i) 3 Nos. 100 Amp. microprocessor based MCCB with Soft starter RS 485 Port- 400 V Class,30 KW (40 HP), Rating(ii) 1 No. MCCB 32 Amp for lighting and fan(iii) 2 No. MCCB 63 Amp for Auxiliary Load 373 Supply of microproceesor based three phase sensing power factor correction relay panel, IEC/EN 61000-6- (2&4) communication interface with RS 485, indication of switching on units, auto /manual status and shall have over load protection, no volt release, having multi parameterlike KW, KVA, KVAR rating capacity of 50 KVAR or suitable capacity 374 Auto Phase reversal unit / Automatic switch with inbuilt the delay & enclosure (Confirms to IEC: 60947-1 & IEC: 60947-6-1) of followint rating: 375 200Amp Rating 376 CE/UL Certified Radar type Level Transmiter for CWR 377 CE/UL Certified Pressure transmitter for each pump. 378 Earthing Complete in all respect. Earthing system shall executed as per IS : 3043 and I.E. rules. (for Motor Pump set and Control Panel) 379 Installation of all Equipments, Power wiring of Electrical equipments with cable tray, cable lugs, cable gland and commissioning of the pumping plants 380 3 Ton / 12 mtr. Lift chain pulley Block with four way motion HOT, Gantry I-section Girder, square rod with travelling trolley. 381 Rubber mat for Electrical purpose as per IS 5424. 1 Mtr. X 2 Mtr. (12.5 mm thick). 382 CO2 type Fire extinguisher ISI mark confirming to IS 15683- 4.5 Kg. 383 Internal & External electrification of Pumping plant. 384 Tools & Sppanners Complete. 385 Electromegnatic dozzer of suitable capacity SCADA compatible 386 CE/UL approved manufacturers Surge protector for all AC control supplies of all equipments. 387 Installation, commissioning & testing of Automation related equipments for ZPS 388 Trial run for 3 month period for one ZPS 389 12 watt solar based LED light with GI pole 390 SCADA of ZPS FOR ZONE -6 391 CE & UL Certified PLC/RTU with redudant CPU & Power supply in IP 54 enclosure sutable to Communicate with GSM based modem unit with redudant CPU & Power Supply with annalog & digital Parameter & features as specified for each ZPS/OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at muliple stations with Control Panel as specified in tender technical specification. 392 G.S.M./G.P.R.S. based wireless communication with 4G modem for RTU/PLC capable to transfer & gather data from remote sites to control stations all accessories included with signal enhancer antenna made for pumping plant internet charges as specified in tender technical specification. 393 CE/UL Certified Intelligent Smart Energy Meter 394 Complete cabling for ZPS including all power & control cable of all equipments at ZPS and OHT (Upto 3 Pumps) 395 Security Survelliance IP Camera with Recorder (optional) 396 Automation of Units of all zone T/W 397 CE & UL Certified RTU/PLC in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & power supply with analog & digital parameters & features as specified for T/W to store and transmit data on GSM Backbone.RTU/PLC designed with logic to transfer data at multiple stations as specified in tender documents 398 GSM/GPRS based wireless communication 4G modem for RTUs/PLC capable to transfer data from remote site to CS with all accessories included with signal enhancer antenna made for pumping plant internet charges as specified in tender documents. 399 CE/UL Certified Intelligent energy meters 400 Auto phase reversal Unit 100 Amp 401 CE/UL Certified Surge Protector for control panel 402 CE/UL Certified 7 HMl touch screen suitable to communicate with PLC/RTU for Local display and control of Process Parameters 403 Control panel with IP 54 protection, industrial grade for all equipments( Separate for control 24 Vand power equipments 404 Installation,Testing and commissioning 405 Trial run 3 months 406 SUB STATION FOR ZPS ZONE-6 407 H.T.Panel( Comprising with 1 no. incomingand 2 -Outgoing. Supplying of indoor type floor mounted metal clad, 11 KV VCB panel with 1No. 630 Amp. incoming VCB & 2 Nos 630 Amp. outgoing VCB totally enclosed, horizontal drawout, horizontal/ vertical isolation type breaker as per IS with all necessory protection and also should be compatible to SCADA operation 408 Transformer Supplying of 160 KVA, 11/0.44 KV, 3 Phase, 50 Hz, Dyn 11, indoor ONAN type, copper wound transformer with OFF load tap changing arrangement on HV side in steps of +7.5% & -15%, LV side @ 2.5% stapping complete with all accessories i/c first filling of filtered dehydrated oil and confirming to IS 1180-2014 & as per specificationcomplete in all respects as required at site. 409 Main L.T. PanelSupply of LT Panel comprisiing of following details. 02 No. 200 Amp. Incoming MCCB Panel shall be mechanically and electrically interlocked completely and 01 Nos 200 Amp MCCB as Outgoing and 01 Nos 80Amp Outgoing for Auxiliary Load suitable for SCADA and all necessary protection equipments and metering equipment as per requirement. 410 Supply of 120 Sq.mm size XLPE cable from 11 K.V.UPPCL metering panel to H.T. incoming Panel, and H.T. panel to Transformer. 411 Supply of H.T. Cable end termination joint kit. 412 Complete in all respect. Earthing system shall executed as per IS : 3043 and I.E. rules. 413 Supply of 1.1 KVgrade 95 sq mm 3.5 core PVCinsulated Armored Aluminum cable fromTransformer to L.T. Panel. 414 Installation and commissioning of 11 KV/0.44KV, substations including 100 KVA, Transformer including HT Panels and L.T.Panel with cable tray, cable lug, cable gland including all labor T&P complete in all respect. 415 CO2 type Fire extinguisher ISI mark confirming to IS 15683- 4.5 Kg. 416 Heavy Duty leak proof fire bucket as per IS 2546/1974 417 Fire bucket stand for 6 bucket 418 Internal & External electrification of Sub-Station 419 Rubber mat for Electrical purpose as per IS 5424. 1 Mtr. X 2 Mtr. (12.5 mm thick). 420 NOC for substation from safety department 421 S.I.T.C of followings E/M items at OHT (zone-06) 422 CE & UL certified Radar type level tranmitter for OHT 423 Motor OperatedActuator with Sluice Valve/Flow control valve (350 mm )-DMA 1 424 CE / UL certified Electromagneticflowmeter of size:350mm-DMA-1 425 Dismantelling joint 350 mm-DMA-1 426 Motor OperatedActuator with Sluice Valve/Flow control valve (300 mm )-DMA 2 427 CE / UL certified Electromagneticflowmeter of size:300mm-DMA-2 428 Dismantelling joint 300 mm-DMA-2 429 S.I.T.C of followings E/M items at OHT(zone-9) 430 CE & UL certified Radar type level tranmitter for OHT 431 Motor OperatedActuator with Sluice Valve/Flow control valve (250 mm )-DMA 1 432 CE / UL certified Electromagneticflowmeter of size:250mm-DMA-1 433 Dismantelling joint 250 mm-DMA-1 434 Motor OperatedActuator with Sluice Valve/Flow control valve (200 mm )-DMA 2 435 CE / UL certified Electromagneticflowmeter of size:200mm-DMA-2 436 Dismantelling joint 200 mm-DMA-3 437 Stablizer for ZPS3 Phase AC automatic voltage stabilizer for 125 KVAor suitable capacity 438 Local Control Station (LCS) 439 CE/UL & BIS Certied industrial grade LED MONITOR with latest configuration as per specification. 440 Desktop/PC with i5/i7 processor for as per spec mentioned in technical bid doucments. 441 CE/UL Certied 3 KVA UPS with batteries as per spec mentioned in technical bid doucments. 442 Full development version of required TAGS SCADA Software with coustomization of Software for MCS as per requirement as per spec mentioned in technical bid doucments. 443 CE/UL Certied local control room PLC with redundant CPU & power supply at MCS in IP54 inclouser as spec mentioned in technical bid doucments. 444 GSM based wireless/Broadband/Equipment communication system forPLC capable to transfer & received data and gather data from remote sites to control stations. All accessories included signal enhancer antenna along with running expences till DLP 445 CE/UL Ceritified Firewall for network protection 446 SURGE PROTECTOR FOR ETHERNET Communication Protection 447 CE/UL Ceritified Industrial grade Ethernet switch. 448 CANON/H.P. or equivalent Laser Printer 1018 or equivalent. 449 Security Survelliance IP Camera for with recorder 450 Installation, commissioning & testing 451 Test and Trial run for 3 Months period 452 Three month trial ofZPS(zone -6)Quantity of sodium hypochloridr require for three month for ZPS 453 Three month trial ofall zoneTubewell 454 Quantity of sodium hypochloridr require for three month for all tubewell 455 Provision for operation of pumping plant (each tubewell 3 No oprator)
Contract Date : 24 Apr, 2025   |   Contract Value : 30.35 Crore
BRR : 6886994 Provision Of Stfe Manufacturing Facility In Drdo Land Near Batl Complex At Thiruvananthapuram; SUBHEAD-I :Dismanteling Works , Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) , Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. , Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 10km initial lead, for all leads including all lifts involved. , Credit for Reinforcement steel obtained form above items , SUBHEAD-II :EARTH WORK & EXCAVATION : , Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 Sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. including pumping out water as required or liquid mud, , All kinds of Soils , Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. . including pumping out water as required or liquid mud, , All kinds of Soils , Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. , Supply,Laying, spreading and compacting stone aggregate of specified sizes to Rubble solling specifications in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density . , SUBHEAD-III :ANTI TERMITE TREATMENT : , Supplying chemical emulsion in sealed containers including delivery as specified. , Chlorpyriphos/ Lindane emulsifiable concentrate of 20% , Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : a) Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.:With Chlorpyriphos/ Lindane E.C. 15% with 1% concentration. , Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 15% with 1% concentration. , SUBHEAD-IV:PLAIN & REINFORCED CEMENT CONCRETE : , Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : , 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) , Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor,etc., up to floor five level, excluding the cost of centering, shuttering and finishing: , 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth. , Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. , Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement , Concrete of M25 grade with minimum cement content of 330 kg /cum , All works upto plinth level , All works above plinth level upto floor v level , Concrete of M25 grade with minimum cement content of 330 kg /cum , All works above plinth level upto floor v level , Add/ Deduct for using extra/ less cement in the items of design mix over and above the specified cement content therein. , Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap). 450 mm dia piles , Supplying, fabricating and fixing in position reinforcement bars at all levels and positions including the cost of steel, straightening, cutting, bending, binding and placing in position etc., as per drawings and specifications including the cost of binding wire, labour etc., all complete for reinforced concrete. , Thermo-Mechanically Treated bars (Fe 500 Grade or More) at all levels , Centering and shuttering including strutting, propping etc. and removal of form for : , Foundations, footings, bases of columns, etc. for mass concrete , Lintels, beams, plinth beams, girders, bressumers and cantilevers , Columns, Pillars, Piers, Abutments, Posts and Struts , Weather shade, Chajjas, corbels etc., including edges , Suspended floors, roofs, landings, balconies and access platform , Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. , Stairs, (excluding landings) except spiral-staircases , Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). , Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) , Vertical load testing of piles in accordingwith IS 2911(Part IV) including installation of loading plateform and Preparation of pile head or construction of test cap and dismantling of test cap arter test etc., complete as per specification & the direction of Engineer-in-charge Single pile upto 50 tonne safe capacity Routine test , SUBHEAD-V : STONE & BRICK MASONRY : , Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with, Cement mortar 1:6 (1 cement : 6 coarse sand). , Providing and laying autoclaved aerated cement blocks masonry with 150mm/200mm/230/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). , Providing and laying autoclaved aerated cement blocks masonry with 100 mm thick AAC blocks in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work. , SUBHEAD-VI :PLASTERING & SURFACE TREATMENT : , Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) : , Flush/ Ruled Pointing , 6 mm cement plaster of mix cement mortar 1:3 (1 Cement : 3 fine sand). , 12 mm cement plaster finished with a floating coat of neat cement of mix 1:4 (1 cement: 4 fine sand). , 15 mm cement plaster on the rough side of single or half brick wall of mix 1:6 (1 cement: 6 fine sand). , 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). , Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. , Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. , Providing and fixing 22 gauge chicken mesh wire at the junction of RCC and brick work with overlapping of 100mm on both sides, etc., complete. , White washing with lime to give an even shade: New work (three or more coats) , Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour (Two or more coats on new work) complete, as per manufacturer’s specification. , Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm , Applying priming coat , With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) , With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works. , Painting with synthetic enamel paint of approved brand and manufacture to give an even shade, Two or more coats on new work , French spirit polishing : Two or more coats on new works including a coat of wood filler. , SUBHEAD-VII :FLOORING : , Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in charge. (The panel shuttering work shall be paid for separately). (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately). , Deduct for using of M-20 grade concrete instead of M-25 grade concrete in C.C. pavement. , Making provision for contraction, expansion, construction and longitudinal joints (size 5x20mm) by groove cutting machine. , Providing and filling in position at expansion joints(size 5x20mm) with poly sulphate sealants of approved brand. , Supply and application of SealArm Tape TPE with adhesive ReArm Bond 4031 for 25mm width expansion joint. Work includes Insert backer rod same or higher dia into the joint and Apply of epoxy adhesiveReArm Bond 4031 first on the flanges of the joint followed by laying tape and press it on the adhesive. Again apply second layer of ReArm Bond 4031 on the tape (sandwiching the tape with adhesive both on top and bottom). Work including surface preparation all incl etc, not incl of joint protection works. Supply and apply of polyurethane sealant to expansion joint. work includes Insert backer rod of same or higher dia into the joint and apply polyurethane sealant - SealArm PU. Ensure that depth of sealant filling is atleast 1/2 of the width of joint as minimum criteria. , Providing and placing the 2.0mm thick and 300mm width aluminium plate as a protection for the tape. , Supplying & Fixing in position of pre-moulded, high performance joint filler board of 25mm thickness in expansion joints in Concrete, brick work, block work or isolation joints and should be rot free and with no bitumen content (ShaliTex Expansion Joint Filler Board of M/s Shalimar Tar Products or equivalent) , 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc., complete. , Providing cement skirting in CM (1:3) 18mm thick finished with a floating coat of neat cementetc., complete. , Supplying and applying Epoxy Flooring System as per the following Specification: Surface Preparation:- Providing and cleaning all floor area to make it free from dirt, dust and other contaminants, making grooves etc .as per manufacturers specification. Priming:- FloArm Primer 1260is a two-component solvent free, low viscous epoxy resin primer for both horizontal & vertical applications. It may also be used for producing leveling and scratch coats for surface preparation prior to final flooring. Epoxy Screed- FloArm ESF 2-M consists of graded aggregates bound is a epoxy resin binder. It is supplied as a 3component system, pre-weighed for on-site mixing. When laid it provides a smooth surface. FloArm ESF 2 M is designed for use in industrial environments where high abrasion and impact loads are likely. It provides a dense, impervious, coloured and chemically resistant floor surface which is hygienic and easy to clean. The designated floor area shall be surfaced FloArm ESF-2 a Heavy duty, trowel applied flowable 2-3 mm thick epoxy resin floor topping. The topping shall achieve a compressive strength of >50N/mm² and a flexural strength of >20 N/mm² at 7 days. , Epoxy Top Coat- FloArm SL-2 M consists of graded aggregates bound in a pigmented epoxy resin binder. It is supplied as a four component system, pre-weighed for on-site mixing. When laid it provides a smooth, light reflective surface. It is available in a range of standard colours. FloArm SL-2 Mis designed for use in industrial environments where high abrasion and impact loads are likely. It provides a dense, impervious, coloured and chemically resistant floor surface which is hygienic and easy to clean. The designated floor area shall be surfaced FloArm FloArm SL-2 M a Heavy duty, trowel applied flowable 2 mm thick epoxy resin floor topping. The topping shall achieve a compressive strength of >50N/mm² and a flexural strength of >25 N/mm² at 7 days. Make of Epoxy Flooring :- MYK or as Approved by Chief Construction Engineer (R&D)South. , Anti Static Flooring Surface preparation:- Providing and cleaning all floor surface including wall up to required height to make it free from dirt, dust, loose particles, wax, polish, efflorescence, laitance, curing compound and other contaminants by using wire brush, grinding all sharp edges to make it flush with the surface etc and complete as per manufacturers specification. , Priming:- Prepared substrates to be treated with FloArm SL Conductive system should be primed with FloArm Primer EP. FloArm Primer EP should be mixed in the proportions supplied by adding the entire contents of hardener can to the base can. Once mixed the FloArm Primer EP, should be immediately applied in a thin, continuous filmusing stiff brushes or rollers. Over application and puddles should be avoided. Porous floors may require two coats of FloArm Primer EP. FloArm Primer EP should be allowed to become tack free (over night Air dry) prior to application of Copper tape and subsequent FloArm SL Conductive Undercoat. Copper tape Fixing: - Make a suitable pattern to lay the copper strips of Copper band in a 5/5 m grid. , Screed:FloArm Cempo4 is a three part; epoxy modified cementitious, fine textured mortar for self-smoothing floors creeds in thinlayers of 4mm , Applying undercoat: The mixed undercoat shall be applied with a roller or brush on the primer at a material consumption rate of 6m²/kg for FloArm SL Conductive under coat. Care shouldbe taken to avoid over application or puddles. Theundercoat provides a Conductive system passagetoearth so correct application and strict adherence tocoverage rates are critical to the final electrical propertiesof the completed floor. Adequate ventilation and air movement are necessary for complete curing of undercoat. Thorough covering of earthing connections isessential. The Resistivity of the undercoat needs to bemeasured before applying the top coat (after overnight Air Dry). the surface resistance (FloArm SL Conductiveundercoat) should be: approx. 3x103- 9 x103 Ohm , Applying Topcoat: When mixed, FloArm SL Conductive Topcoat should bepoured immediately on to the surface and spread @2mmwith a steel trowel or a float. Immediately after applicationthe surface should be firmly rolled in perpendicular directions with a nylon spiked roller to help release anyentrapped air in the material and help to spread any slight trowel marks. Make of Anti Static Flooring :-MYK or as Approved by Chief Construction Engineer (R&D)South. , Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick. , Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. , Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Size of Tile 600 x 600 mm , Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @3.3kg/sqm including pointing the joints with white cement and matching pigments etc., complete. , Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. , Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. , Polished Granite stone slab of all colour and texture except Black, Cherry/Ruby Red , SUBHEAD-VIII :STEEL & WOOD WORKS : , Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete , Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete Fixed to openings /wooden frames with rawl plugs screws etc. , Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including MS pressed blet hinges 2.50mm thick with morter guards, lock strike plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: , Profile B, fixing with adjustable lugs with split end tail to each jamb , Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: , 35 mm thick , Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. , Providing and fixing to existing door frames, 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. , Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). , Providing and fixing the following hardware fittings of approved make: , 200mm long SS Tower Bolts , SS Aldrop 300mm long , Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. , 125mm long , Providing and fixing aluminium hanging floor door stopper (Single rubber stopper), ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. , Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. , Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. , Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm). , Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron)work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws.(Glazing, paneling and dash fasteners to be paid for separately) : , For sliding windows & ventilators including the cost in-built roller track, uPVC extruded interlocks, EPDM rubber,wool pile, zinc alloy ( powder coated) touch locks with hook, zinc alloy body with single nylon rollers (required weight bearing capacity ),neoprene gasket, G.I fasteners riquired size for fixing frame to finished wall and necessary stainless steel screws etc all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazingand paneling to be paid for separately, Only weight of aluminium sections to be measured for payment). , Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : , For fixed portion , Powder coated aluminium (minimum thickness of powder coating 50 micron) , For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) , Powder coated aluminium (minimum thickness of powder coating 50 micron) , Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): , With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm) , Providing and fixing Motorised Sliding Door of size 6 x 8 mCE Certified As Per European Standard BS EN 13241-1:2003+A1:2011 Single Side 0.50 mm thick GI Cladding Sheet Both Side Automation System : Bottom Drive Inbuilt wicket door with, locking arrangement & auto sensor - (w)1000 x (h)2100 mm Enamel Paint including all necessary fittings,hardwares etc complete as directed engineer in charge. , Providing and fixing Motorised Sliding Door CE Certified As Per European Standard BS EN 13241-1:2003+A1:2011 Single Side 0.50 mm thick GI Cladding Sheet Both Side Automation System : Bottom Drive Enamel Paint including all necessary fittings, hardwares etc complete as directed engineer in charge. , D1 ( 3.5 x 2.1) , D2 (2.5 x 2.1) , Providing and fixing Motorised GI Rolling Shutter CE Certified As Per European Standard EN 13241-1:2003+A1:2011 GI Slat Box Type Guide Powder Coated Motorised System : Indirect Drive With Std. Control Push Button - 1 No. Hood Cover - R/Meter including all necessary fittings,hardwares etccomplete as directed engineer in charge. , RS1 (4 x 3) , RS2 (3 x 3) , Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 -part 1 and M.S. top cover of required thickness for rolling shutters. , 80x1.25 mm M.S. laths with 1.25 mm thick top cover , Providing and fixing ball bearing for rolling shutters , STRUCTURAL STEEL : , Analysis, Design, Engineering, Preparation of Detailed Drawings, MAnufacturing, Fabrication, Supply, Loading,Transporting to SIte, Unloading, Erection of Steel PEB(Pre-Engineered Building)System, Consisting ofMS Platesof 345MPayield strength and Coating Thickness of 275gsm forcolumns, jack trusses, crane beams, Platforms, canopies, lattice girders, rafter , sub rafters ,at all elevations, levels and heights including aligning, leveling, providing and fixing bolts, nuts, washers, comprising MS angles, chann`els, joists, rails, tees, plates, rounds, squares,etc., of various sizes and other structural steel sections conforming to latest IS CODE including straightening, cutting, welding, bending to shape, bolting,and inclusive ofGrit / sand blasting and applying two coats ofSynthetic Enamel paint over one coats of approved Zinc Chromate primer . , The rate to include the cost of all materials, labours, tools, tackles, cranes, devices and plants, bolts, nuts, washers, clamps, welding electrodes and connection required for work, shims and packing pieces, any cutting, fabrication work required on electrically operated machines in the work shop including transportation to site and erection as per specifications and drawing complete. , a) For trusses , Rafters, gable frame ,lattice girders, Jack Beam, Crane beams, Columns.etc at all heights. , Supplying, fabricating, hoisting and erecting in position Purlins , cladding runners, girts of minium 345mpa yeild strength at all elevations, levels and heights including aligning, leveling, providing and fixing bolts, nuts, washers, comprising MS angles, channels, joists, rails, tees, plates, rounds, squares etc.,of various sizesincluding straightening, cutting, welding, bending to shape, bolting,Acid Pickling / GALVANISING of minium 120gsm &inclusive of following finishes. structural Grit blasting and applying two coats ofSynthetic Enamel paint over one coat of Zinc Chromate primerofapproved make and colouras per specifications and drawing complete. , Providing and fixing in position GI High Strength Foundation Bolts of approved make ofwith nuts of various diameters and lengths confirming with IS 4000-1992, Class 8.8 Type I for joining of various Structural components like Column, Rafters, Jack Beams,etc., including work at all levels and locations complete all as shown in the drawing , Roof Sheeting TOP SHEET : Supply of 360-degree FORTISS™ 470 standing seam panels shall be 470mm effective cover width, 73mm rib height, with strengthening rib/ flute in the pan for strength. The end lap shall be seamed with 360 degree seeming using Seamer machine. The sheeting material shall be 0.50 mm Base Metal Thickness (BMT), (0.55mm TCT, 0.58mm TPT). The steel sheet is having high tensile strength G300 (Fy=300Mpa), metallic coated with Zinc-Aluminium alloy (i.e. 55% Al, 43.4% Zinc, 1.6% Si - Zincalume), AZ150 (min 150 g/m2 total on both side), pre-painted with NextGen COLORBOND® XRW. The sheet conforms to general requirement of AS/NZS 2728 type 4 / IS 15965 class 3 durability of Tata BlueScope Steel make. The sheet shall be IGBC Green pro, Griha, EPD certified and steel sheet shall have brand marking of coated steel manufacturer (product details, date, mfg. name, etc.) on back side at regular interval confirming genuinity of the material. , ROOF INSULATION: Insulation shall be 50mm thick, density 48kg/m3 Rockwool with or without facing as per design requirement complying with IS8183 BS - 3958 Part-5. ASTM C592-80, as approved by engineer in-charge shall be laid uniformed over Purlin. SUB GIRTS: LYSAGHT ZED-plus™ purlins and Girts 1.5mm thick high strength galvanized steel with min 345 MPa yield strength, zinc coating of Z275 (275 g/m2 minimum coating mass) confirms to IS 277 / IS 15961 pre-punched to the required dimensions, suitable for roof and wall cladding support and portal framing up to a certain span. The design of cold formed ZED-plus purlins sections shall be subject to the requirement of IS 801 / AISI 1996, cold formed steel structures code. LINER - Bottom Sheet : Pre-painted Zincalume trapezoidal sheets shall be made of 0.45mm BMT (0.50mm TCT, 0.53mm TPT), G550 (min 550 yield strength), 1015mm effective cover width with five major corrugation, 28mm high rib spaced at 203mm c/c with subtle square fluting in the pan and the end rib shall have anti-capillary groove and return leg of Lysaght Trimdek. Color : COLORBOND XRW Standard or as Approved by Chief Construction Engineer (R&D)South. Make of Sheeting :-Tata Blue Scope or as Approved by Chief Construction Engineer (R&D)South. , Wall Panelling OUTER SHEET : Pre-painted Zincalume trapezoidal sheets shall be made of 0.45mm BMT (0.50mm TCT, 0.53mm TPT), G550 (min 550 yield strength), 1015mm effective cover width with five major corrugation, 28mm high rib spaced at 203mm c/c with subtle square fluting in the pan and the end rib shall have anti-capillary groove and return leg of Lysaght Trimdek. Steel should be metallic coated with Zinc-Aluminium alloy (i.e., 55% Al, 43.4% Zinc, 1.6% Si - Zincalume), AZ150 (min 150 g/m2 total on both side), pre-painted with NextGen COLORBOND® XRW. The sheet conforms to general requirement of AS/NZS 2728 type 4 / IS 15965 class 3 durability of Tata BlueScope Steel make. The sheet shall be IGBC Green pro, Griha, EPD certified and steel sheet shall have brand marking of coated steel manufacturer (product details, date, mfg. name, etc.) on back side at regular interval confirming genuinity of the material. , Wall INSULATION: Insulation shall be 50mm thick, density 48kg/m3 Rockwool with or without facing as per design requirement complying with IS8183 BS - 3958 Part-5. ASTM C592-80, as approved by engineer in-charge shall be laid uniformed over Purlin. SUB GIRTS: LYSAGHT ZED-plus™ purlins and Girts 1.5mm thick high strength galvanized steel with min 345 MPa yield strength, zinc coating of Z275 (275 g/m2 minimum coating mass) confirms to IS 277 / IS 15961 pre-punched to the required dimensions, suitable for roof and wall cladding support and portal framing up to a certain span. The design of cold formed ZED-plus purlins sections shall be subject to the requirement of IS 801 / AISI 1996, cold formed steel structures code. LINER - INNER Sheet : Pre-painted Zincalume trapezoidal sheets shall be made of 0.45mm BMT (0.50mm TCT, 0.53mm TPT), G550 (min 550 yield strength), 1015mm effective cover width with five major corrugation, 28mm high rib spaced at 203mm c/c with subtle square fluting in the pan and the end rib shall have anti-capillary groove and return leg of Lysaght Trimdek. Color : COLORBOND XRW Standard or as Approved by Chief Construction Engineer (R&D)South. Make of Wall Panelling :-Tata Blue Scope or as Approved by Chief Construction Engineer (R&D)South. , Providing and fixing tiled false ceiling of approved materials of size 595x595 mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross T of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main T at 600 mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. , Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. , 8 mm thick fully perforated calcium silicate board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process to give stable crystalline structure with minimum compressive strength 225 kg/ sq. cm, bending strength 100 kg/sq. cm , of size 595x595 mm, having perforation of dia. 10 mm with minimum perforated area 18 % with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.85, with 50 mm thick rockwool of 48 kg /cum backing. , Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, , shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : , 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) : 2011 (Board with BIS certification marks) , Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). , SUBHEAD- IX : MISCELLANEOUS: , Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: , a) Applying a slurry coat of neat cement using 2.75 kg/Sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. , b) Laying brick bats with mortar using broken bricks/brick bats 25mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. , c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ Sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. , d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement : 4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300mm square 3 mm deep. , e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.All above operations to be done in order and as directed and specified by the Engineer-in-Charge, with average thickness of 120 mm and minimum thickness at khurra as 65 mm. , Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. , Single socketed pipes of 110mm diameter , Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. , 110mm Bend 87.5° , 110mm Shoe (Plain) , Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. , 110mm , Providing and fixing Duraborad HD100(Formely Known as Capcell HD100/Silflex) The most Compressible Filler boad for expansion joint with Density of 100kg/cum.in 100mm Thickness , SUBHEAD-X : SANITARY SERVICES: , Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : , White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. , Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : , W.C. pan with ISI marked white solid plastic seat and lid. , Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc., including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. , Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. pan. , Providing and fixing white vitreous china flat back urinal basin of 430x260x350 mm size. , Providing and fixing C.P 15 mm Urinal spreader size 95x69x100 mm with 1/2 BSP thread and shapes, weighing not less than 60 gms. , Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required : , White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar taps. , Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. , Providing and fixing toilet paper holder, C.P. Brass. , Supply and fixing of 15 mm CP Health faucet Cum bib tap with 1.25 mts long tube with end nuts and hook and 1 no 15 mm CP brass angular stop cock with wall flange, Hook to be fixed with CP brass with suitable counter sunk screws, all of approved make etc., complete. , Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. , Granite of any colour and shade. , Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc., complete as per design approved by Engineer-in-Charge. , Granite Work , Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/Granite/stone work, including necessary holes for pillar taps etc., including moulding, rubbing and polishing of cut edges etc. complete. , Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. , Granite Stone of approved shade , Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. , 32mmdia Flexible pipe , Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. , Providing and fixing CP towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. , Providing, fixing, testing and commissioning of 75 mm pipe diameter uPVC SWR Type B pipe comforming to IS : 13592, including jointing with seal ring conforming to IS : 5382 for vertical pipe & Selfit uPVC Adhesive solvent joint inside in the toilet, including all fittings such as bends, junctions, inspection doors, offests, cowl, clean out, access pieces/plugs etc. complete the job. The rate shall be including all the engineered support at every one Meter (support, hanger, nuts/ bolts, anchor fasteners, fixing clamp/channels with U-bolts, etc) as per detail technical specification etc. complete the job. , 100mm dia upvc/ SWR Single socket , 75mm dia UPVC/SWR Single socket , Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete for UPVC SWG Pipes conform to is 13592-1992. , 100mm dia UPVC/SWR Single socket , 75mm dia UPVC/SWR Single socket , Providing and fixing PVC door bends as per IS - 13592-1992 single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. , 100x100x100 mm , 75x75x75 mm , Providing and fixing terminal guard, Sand cast iron S&S as per IS - 3989. , 100mm dia. , 75mm dia. , Providing and fixing M.S. stays and clamps for pvc pipes of diameter. , 100mm , 75mm , Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors, Sand cast iron S&S as per IS: 3989. , 100 mm inlet and 100 mm outlet , Cutting chases in brick masonry walls for following diameter sand cast iron/ centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size), including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 coarse sand) : , 100mm dia. , 75 mm dia , Supply and fixing in position best quality and approved make CP brass coat hooks with flanges fixed to wall/door shutters with necessary screws washers etc., complete. , SUBHEAD-XI :WATER SUPPLY SERVICES: , Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. - External Work. , 25 mm dia nominal bore , 32 mm dia nominal bore , 40 mm dia nominal bore , Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc., , 15 mm dia nominal bore , 20 mm dia nominal bore , Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : , 25 mm dia nominal bore , 32 mm dia nominal bore , 40 mm dia nominal bore , Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. , Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : , 25 mm nominal bore , Providing and fixing CP brass bib cock of approved quality : , 15 mm nominal bore , Providing and fixing CP brass stop cock of approved quality : , 15 mm nominal bore , Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931. , 15 mm nominal bore , Making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc. , SUBHEAD-XII : INTERNAL ELECTRIFICATION : , Point Wiring for Light/ Fan/ exhaust fan with 2 runs of 1100V grade 1.5 Sq.mm & 1 run of1.5 Sq.mm PVC insulated multistrand , FRLS , Copper conductorwires , run in and including 25mm dia heavy gauge PVC conduits concealed in wall / ceiling conforming to IS732 including all accessories such as junction boxes, conduit bends elbowsand anodised GI Switch box with modular switch and the box coveredwith front plate including connections to Earth terminal. , One Light point controlled by one 6 Aswitch. , Two Light point controlled by one 6 Aswitch. , Three Light point controlled by one 6 Aswitch. , Four Light point controlled by one 6 Aswitch. , Ceiling fan point controlled by one 6 A switchand electronic fan regulatorof 100 W step typewith concealed MS fan hook box. , Exhaust fanpoint controlled by one 6 A switch. , Point Wiring for Light/ Fan/ exhaust fan with 2 runs of 1100V grade 1.5 Sq.mm & 1 run of1.5 Sq.mm PVC insulated multistrand , FRLS , Copper conductorwires , run in and including 25mm dia, 14SWG black enameledMS conduits surface / concealed in wall / ceiling conforming to IS732 including all accessories such as junction boxes, conduit bends elbowsand anodised GI Switch box with modular switch and the box coveredwith stainless steel front plate including connections to Earth terminal. , One Light point controlled by one 6 Aswitch. , Two Light point controlled by one 6 Aswitch. , Three Light point controlled by one 6 Aswitch. , Four Light point controlled by one 6 Aswitch. , Point Wiring for Light/ Fan/ exhaust fan with 2 runs of 1100V grade 2.5 Sq.mm & 1 run of2.5 Sq.mm PVC insulated multistrand , FRLS , Copper conductorwires , run in and including 25mm dia , 14 SWG black enameledMS conduits surface / concealed in wall / ceiling conforming to IS732 including all accessories such as junction boxes, conduit bends elbows etc including connections to Earth terminal. , One Light point controlled by one 6A SP MCB , Two Light point controlled by one 6A SP MCB , Three Light point controlled by one 6 ASP MCB . , Four Light point controlled by one 6 ASP MCB , Point Wiring for Light/ Fan/ exhaust fan with2runs of 1100V grade 1.5 Sq.mm & 1 run of1.5 Sq.mm FRLS insulated multistranded Copper wires, run in & including 25mm dia, 14 SWGMS conduitssurface / concealed in Slab/ wall after necessary chase cutting with finishing/surface in wall / ceiling conforming to IS 732 including all accessories such as junction boxes, conduit bends, elbows and ceiling rose, anodised GI Switch box withmodular switch and the box coveredwith front plate and alsoincluding connections to Earth terminal. , One Light point controlled by one 6A Switch , Two Lights point controlled by one 6A switch. , Three Lights point controlled by one 6A switch. , Four Lights point controlled by one 6A switch. , Supply and laying of 25mm dia, 16 SWG black enamelled M.S. conduit concealed in wall/ ceiling/ floor including all accessories such as junction boxes, conduit bends, etc., complete as required for Telephone etc., , Supply and laying of 32mm dia, 16 SWG black enamelled M.S. conduit concealed in wall/ ceiling/ floor including all accessories such as junction boxes, conduit bends, etc., complete as required for Telephone etc., , Supply and fixing of 6A, 3Pin Socket outlet with 6Aswitch in Lighting switch boards. (Dependant). , Supply and fixing of 6A, 3Pin Socket outlet with switch of 6A ratingwith wiring of 2 Runs of 2.5 Sqmm and1 Run of 2.5 Sqmm FRLS, PVC insulatedmultistranded Copper conductorwires run inand including 25 mm Dia, 2 mm thick PVC conduit. (Independant). , Supplying and fixing suitable size GI box with modular Stainless Steelplate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in Clean Room). , Supply and Wiring with the following size 1100V grade PVC insulated multistrandFRLSCopper conductor wires inand including suitable size heavy gauge PVC conduit concealed in wall / Ceiling including all accessories suchas junction boxes, bends, elbows including end terminated with suitable lugs. , 2 runs of 2.5 Sq.mm wires with 1run of 2.5 Sq.mm wire in and including25 mm Dia PVC Conduit (For Lighting Circuit) , 4 runs of 6 Sq.mm wires with 2 runS of 6 Sq.mm wiresin and including32 mm Dia PVC Conduit (For Lighting Sub Mains) , Supply and Commissioning of thefollowing type Fluorescent/ Compact fluorescentlight fixtures on wall/ Ceiling including all fixing accesssories such as leads, etc complete as required. The Fluorescent/CFL fixtures shall be complete with Low loss copper ballast PF improvement capacitor, Bipin Rotor type lamp holder,starter, starter base, all prewired upto the terminal block. All fixtures shall besupplied with lamps. The Catalogue Numbers refers to Philips Make. , 36 W Surface mounted LED 4 Feet LengthLuminaire , (Philips : BN308C LED40S-6500 L120 PSU WH/or Equivalent as per approved makes) , 1 x12 WSurface MountedLED Luminaire , (PhilipsCat No : SM250C LED 12S-6500PSU WH or Equivalent as per approved makes) , 40 WRecessMountedLEDLight Fixture , (PhilipsCat No :RC 380 B LED 40S-6500 G4L60W60 PSU OD/Equivalent as per approved makes) , 20W Recess mounted DownLight Fixture , (PhilipsCat No DN296B LED20S-6500 PSU WH S2/Equivalent as per approved makes) , 36W Surfacemounted SquareLight Fixture , (PhilipsCat No SM36S -6500 G6L54W54PSU OD/Equivalent as per approved makes) , 40 W Bulk Head Light Fixture Indoor , (PhilipsCat No WT 202W LED 10S CW PSU S3 PC/Equivalent as per approved makes) , 210WLED High Bay Light Fixture , (PhilipsCat No BY616P LED200S 5700 WB PSU GR/Equivalent as per approved makes) , 104WLED High Bay Light Fixture , (PhilipsCat No BY225P LED104S CW SYWB PSU FG GR V2/Equivalent as per approved makes) , 36WLED2 X 2 Top openable cleanroom Light Fixtures , (PhilipsCat No CR652B LED36S-6500 PSU CA BO W30L120 WH /Equivalent as per approved makes) , Supply and Installation Testing and Commisioning of 1200 mmsweep single phase Ceilingfan including fixing accessories etc., complete.( BEE 5 star rated ceiling fan ) , Supply and Installation Testing and Commisioning of 600 mm dia sweep single phase wall mounted fan including fixing accessories etc., complete. , Supply and Installation Testing and Commisioning of 600 mm dia Air circulator single phase wall mounted with metal blades including fixing accessories etc., complete. , Supply and commissioningof305 mm sweep Exhaust fans with Metallic blades and MS gravity louversincluding all accessories / Installation materials required. , Installtionof Fluorescent/ Compact fluorescentlight fixtures on wall/ Ceiling including all fixing accesssories such as leads, etc complete as required. , Installation of 1200 mm sweepwhite colour Ceiling fan with standard down rod(600mm length down rod in false ceiling areas) andall accessoriesas required etc complete. , Installationof305 mm sweep Exhaust fans with Metallic blades and MS gravity louversincluding all accessories / Installation materials as required. , Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powderpainted including earthing etc. as required. (But without MCB/RCCB/Isolator) , 8 way (8 + 24), Double door , 4 way (8 + 12), Double door , Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuitbreaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. , 40A , Supplying and fixingof 6A to 32A rating 240/415V,10kA , C Curveminiature circuit breaker suitable for inductive load of following polesin the existing MCB DB complete with connections ,testing and commissioning etc complete. , Single Pole , Supplying and fixing following way, vertical type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powderpainted including earthing etc. as required. (But without MCB/RCCB/Isolator) , 8 way (4 + 24), Double door , Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, molded case circuitbreaker (MCCB), having a breaking capacity 25 KA in the existing MCB DB complete with connections, testing and commissioning etc. as required. , 160A 4P MCCB, 25 kA , Supplying and fixingof following rating 240/415V,10kA , C Curveminiature circuit breaker suitable for inductive load of following polesin the existing MCB DB complete with connections ,testing and commissioning etc complete. , 40A Three Pole MCB 10 kA , SUBHEAD-XIII : AIR CONDITION: , HVAC SYSTEM , All works should include Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over , All the equipments shall be five star rated only , All Techincal data sheet & drawing shall be submitted and get approved by department before supply , All equipment factory inspection shall be carried out by department , First prefers as per BOQ followed by Techincal specification , VARIABLE REFRIGERANT FLOW (VRF) / VARIABLE REFRIGERANT VOLUME (VRV) , Supply, Installation, Testing & Commissioning & Handing over of the following: , HIGH SIDE VRF/VRV EQUIPMENT , VRF/VRV HI BRID AIR-CONDITIONING EQUIPMENTS: (100% INVERTER TYPE ONLY TO BE QUOTED) - R410A Refrigerant , Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over of VRV/VRF air conditioning systemunit suitable for cooling and heatingmode having all hermetically sealed inverted type screw compressor with 5 Star and above Rating as per OEM comprising of Modular type high efficiency Twin Rotary MultipleCompressor with inverter, High efficiency heat transfer Cooling Coil suitable for Environment friendly R410a refrigerant,Air cooled propeller type condenser fan with DC motor drive,interconnecting piping, suction line insulation etc., Micro-processor control panel suitable for automatic operation,High speed calculation inverter control, active oil control mechanism incorporating all safety functions as per equipment specifications & other points as listed below: , The unit mounted starter panel shall be complete with IP-65 protection consisting of power disconnecting switches with fuses, soft starters, for compressor motors, under/over voltage trip, single phase preventers, communication card which can accept 4-20 mA or 2-10 Vdc analog signal. , All components shall be mounted on welded steel base frame, structural steel profiles/panels made out of galvanized sheet steel, protected with primary coat & finished with epoxy paint. , Modular type outdoor units equipped with highly efficient scroll compressors, withinvertertype compressor(s),special acryl precoated heat exchanger,low noise condenser fan,auto check function for connection error, auto address & UNIT Price shall be inclusive of outdoor stand price. Shifting & Installing of ODU as per shop drawing is part VRV vendor scope.(ODU Location & Capacity mentioned below). Shifting of Out door units from GF to repective location is part of VRF vendor scope . ODUs shall have service valve station for easy operations and monitoring of system , All VRV units should be compatible for third party BMS integration .necessary integrator should be consider in part HVAC VRF/VRV vendor scope (Bacnet over MSTP protocol to be considered for BMS compatibility requirement). Centralized controller shall be considered combined for all the VRF/VRV indoor and outdoor units and same to be located in a specific location as per client requirement. , Supply & providing of MS stand for VRF/VRV ODU along with proper supports-suitable for above configuration , Installation and pressure testing with nitrogen Gas, Vaccumising including all consumables for all system shall be part of scope of supply (Pre commissioning ) , First Filling, testing, commissioningincluding topping up of R410 A Refrigerant Gas. , Factory acceptance test to be conducted for all the units and cost of the same to be included , Testing tools and instruments of approved make and required quantity tobe maintained by Contractor , Contractor shall engage dedicated commissioning manager for project and shall coordinate for all testing activities and documentations , Central remote controller should be considered and provided along with VRF/VRV units , With all necessary accessories including vibration insolation i.e fixing etc complete. , Lifting, shifting and positioning of VRF/VRV System as per design location , Outdoor unit suibtable for both cooling & heatingmode having all hermetically sealed inverted typescroll compressor, minimum two compressors for above 14hP Modules, microprocessor based controller. , The unit shall be delived the rate capacity at AHRI conditions and work even at 50c ambient temperature with out tripping , The COP at AHRI conditions shall not be less than3.1 and IEER not less than 6.5.The motor shall be by IEE3 Rated , (*Note:The cost includes themaintenancegranttee includes 24months from the date ofCommissioning without any additional cost) MAKE: Daikin, Blue star, Voltas, Carrier, Trane. , Outdoor Unit (ODU) : Cooling Capacity : 218HP (OFFICE, LAB & QC LAB) , Outdoor Unit (ODU) : Cooling Capacity : 65HP (CLEAN ROOM) , Outdoor Unit (ODU) : Cooling Capacity : 220HP (WORK SHOP) , INDOOR UNITS , Indoor Unit (IDU):Coolingtype All the units should be supplied with thermostat control. The following Indoor unit capacities are required for each type of Room including heating & cooling mode. considered for Auto change over,failure status,overload sequencing etc. Along with proper supports-suitable for above configuration With all necessary accessories i.e fixing etc complete. , It should be suitable for BMS connectivity with necessary accessories. , 4-WAY CASSETTE UNIT , Four way Cassette 1.6TR , Four way Cassette 2.0TR , Four way Cassette 2.6TR , Four way Cassette 3.2TR , HI-WALL SPLIT UNIT , Hi-wall Unit 1.0TR , Hi-wall Unit 2.0TR , Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over of the following Inverter model with5 star capable Cool type split AC unit with high wall mounted Single Split indoor unit and outdoor condensing unit Hermetically sealed compressor suitable for operation on 230V, 50Hz, 1Phase AC supply capable of performing Heat, cool, dehumidifying, air circulating and filtering with cooling and condensing units with 3 mts of copper piping, insulation kit and 4 mts of 4 core copper flexible chord with cordless remote control etc., dual barrier coating in order to protect coil form oxidigation and with copper condenser only. , Hi-wall Unit 1.6TR5 star capable ofdelivering 19200 BTU/hr and above with operating on refrigerant R-32/ R-410A, COP not less than 4.5 , Hi-wall Unit 2.0TR5 star capable ofdelivering 24000 BTU/hr and above with operating on refrigerant R-32/ R-410A, COP not less than 4.5 , AIR HANDLING UNITS , Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over of following capacity floor mounted Thermal Break Double skin construction with internal and external sheets of 1.0 mm thickness with galavanizing of 120 gm/m2 ,Air handling unit made out of extruded aluminium structural frame work. Panels shall be made of 50 mm PUF injected panels having density 43 Kg/m3 in galvanised sheet casings having scratch free preplasticised coating on galvanised sheet on external side and plain GI inner sheet. The whole unit shall be mounted on spring isolators , i) The Air handling unit shallcomprise of fan section with Plug Fan/ Backward curvedfanwith limit load characteristics , spark proof fan. fan mounted on the scroll and not on the casing, coil section comprising of vrv/vrf water coil,stainless steel drain pan under coil section, Filter section comprising of prefilter 10 micron and 3 micron fine filters,mixing box along with RA and FAdampers etc. complete in all respect whether specifically speltor not but required to complete the system works. , The entireunitcasing shall be weather proof , made out of50 mm thk.43 Kg/ cum densitydouble skin PUF panels. The entire assembly of the unitshall be mounted on a rigid GSS base frame. Inner skinof the panel shall be 1 mm thickGSS plain and the outer skin shall be with 1 mm thk. Pre plasticized powder coated. The total unit along with VRV/VRF coils and hot water coil shall be AHRI certified. The face velocity of the coils shall not exceed 500 FPM . Theface velocity across the filters shall not exceed 500 FPM. , The coils and filters shall be full face of the unit. The fan and motor shall be mounted on a common base frame with cushy foots / spring isolator to avoid vibration transmission to the base of the unit. The motor shall be effiency 1 and with VFD compatable. , The fan shall be AMCA certified and motor shall be energy efficientEFF1. The fan out let velocity shall limit to 12 m/ sec. The fan access door shall have safetydoor interlock arrangement with motor. The unit shall be supplied withfire retardantdouble canvass connectionbetween the fan out let and supply air flange. , Variable frequency drives including harmonic filters and surge suppresors to be installed in independently with bypass starter panel and also differential pressure sensorwith cabling from the sensor located on the duct to the VFD for Air handling units of following capacity Motors including necessary fittings and fixing accessories etc., complete , The unit shall be supplied with an outletflange at the the supply air side along with opposed blade volume control damper. The damper casing and blades shall be made out of 16 G Aluminum. , The scope includes one set of commissioning filters along with the VFD & Starter panel with Bypass and control panels with MCB,MCCB. , The AHU unit shall outdoor type with all season weather proof protection , The noise level at all-round the unit shall limit to 60 dBA from 1 m distance to the unit. , The fan curves, coil selectionandtechnical data sheet shall be submittedby vendor for scrutiny. , The unit shall be included withAHU & VFD DRIVE STATER & CONTROL PANEL , The unit shall be included withAHU CONTROLL KITS WITH CORDED REMOTES , Unit shall be ultra violet lamp to kill germs/fungus , AHU1 - 30TR capacity , total air qty 12000 cfm, 65mm Static pressure with suitable High efficency motor, 24sqftarea of6 rowcoil(QC LAB). , Heater section should be with 8kW electric strip heater in 2 banks (QC LAB). , AHU2 - 52TR capacity , total air qty50000 cfm, 150mm Static pressure with suitable High efficency motor, 100sqftarea of6 rowcoil (ASSEMBLY HANGER). , Heater section should be with 12kW electric strip heater in 2 banks (ASSEMBLY HANGER). , AHU3 - 44TR capacity, total air qty 17600 cfm, 125mm Static pressure with suitable High efficency motor, 35.2sqftarea of6 row coil (WORKSHOP). , Supply and fixing of thyristor control Duct Heater Bank for humidity control 14kw capacity & necessary accessories to maintain RH (WORKSHOP). , Imported fittings like Y-Joints and headers etc as per the layout (additional supports should consider for both ends of the Y joint) With all necessary accessories i.e fixing etc complete. , CENTRAL CONTROLLER & REMOTE SYSTEM (FOR VRF UNITS) , Centarl controller integrating advanced I Touch screen display Controller type (System controller) for floor Indoor units with necessary software & spare parts. It shall be BMS compatible with BACNet over MSTP output to connect to the main IBMS system and showes real time data for both temperature Limitation and RH% in screen display. This Controllershall be stand-alone controller with features like visual navigation, graphical report, Multi-PC accessand have the capability to program for sequential operation of indoor units etc.,complete. , LOW SIDE VRV/VRF EQUIPMENT , REFRIGERANT PIPING , Interconnecting copper refrigerant pipe work duly insulated with elastomeric nitrile rubber typetubular insulation betweenindoor & outdoor units as per specifications . All piping inside the room shall be properly supported with hanger and all piping should be run in perforated cably tray.Cable tray qty specified seperately.. MS supports for refrigerant piping & cables, using angles, channels, Tees, flats, etc should be considered as part of scope.All MS supports shall be given a coat of red-oxide primer and two coats of synthetic enamel paint of approved colour. Class O insulation to be considered for the piping insulation. Cu.pipes shall be supported with PVC sleeves with clamps around and all wall/partition crossings shall have PVC sleeves , 41.3mm OD (insulation =19 mm thick) , 38.1mm OD (insulation =19 mm thick) , 34.9mm OD (insulation =19 mm thick) , 31.8mm OD (insulation =19 mm thick) , 28.6mm OD (insulation =19 mm thick) , 25.4mm OD (insulation =13 mm thick) , 22.2mm OD (insulation =13 mm thick) , 19.1mm OD (insulation =13 mm thick) , 15.9mm OD (insulation =13 mm thick) , 12.7mm OD (insulation =13 mm thick) , 9.5mm OD (insulation =13 mm thick) , 6.4mm OD (insulation=13mm thick) , DRAIN PIPE , Supply & Installation ofCPVC drain pipe insulated with 6 mm thick closed cell FM approved class O nitriler rubber insulation. Necessary U trap for units with clean out plugs to be provided. , 32 mm dia , 25 mm dia , Providing & fixing of 2 Cx 1.5 sqmm cu. cable for control cum trans-mission between Indoor unit and Out Door Unitthrough PVC Conduit. , Supply & providing of MS stand for VRV ODU along with proper supports-suitable for above configuration also including coat of red-oxide primer and two coats of synthetic enamel paint of approved colour. , Supply and installing following size of perforated Hot Dipped Galvanised iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections,joined with connectors,suspended from the ceiling with G.I. suspenders including including Cover on above tray, G.I. bolts & nuts, etc. as as required and also inculding 14 SWG GI cover sheet with 40x5mm GI strip on both sides. , 150mm wide x 75mmHeight, 1.6mm thick , 300mm wide x 75mmHeight, 1.6mm thick , 450mm wide x 75mmHeight, 1.6mm thick , MECHANICAL VENTILATION SYSTEM , Supply, Installation, Testing & Commissioning & Handing over of the following: , Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over of the Circular Inline fan Supplying, installing, testing and commissioning of low noise silent type Inline fan with @15mm WC static pressure. The motor shall be suitable for 220 volt single phase 50 cycles AC supply, 6/15 Ampplug and wiring between the fan and the socket andlow sound level exceeding not more than 50dBA. Fan shouldbe complete with all accessories, gravity louver/ shutter as required etc., as per manufacturer specification including transportation to site, all mounting arrangements like brackets etc.,as per specification including transportation to site, all mounting arrangements like brackets etc. It should be suitable for BMS connectivity with necessary accessories and cost of all accessories and all labour charges complete. , Circular Inline fan 100CFM/15mm WC static pressure , Circular Inline fan 200CFM/15mm WC static pressure , Circular Inline fan 400CFM/15mm WC static pressure , Circular Inline fan 500CFM/15mm WC static pressure , Circular Inline fan 600CFM/15mm WC static pressure , Circular Inline fan700CFM/15mm WC static pressure , Circular Inline fan 800CFM/15mm WC static pressure , CLEAN ROOM , CLEAN ROOM FALSE CEILING , Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over of the False ceiling panels are designed to fit within each other and suspended by threaded tension bars to the overhead support at fixed intervals , Standard Ceiling Panels have a composite construction of two skins of powder coated GI over an GI frame work with a sealed and insulated interior. 150-200 Kg per sq. mtr load bearing & factory manufacture only to be supply. , 50mmdouble Skin Walkable False Ceiling made of 0.45 mm both Top & Bottom with pre coated GI Sheetswith mounting accessories PUF as in fill (40 +/-2 kg./m3).False ceiling support rods lengthsuit to site condition. Note: 1.All ceiling joints and gaps between panel to panel, ceiling elements (such as HEPA module, diffusers, pipe & electrical drops etc.) etc. to be sealed usingApprovedfood grade silicon sealant of same or nearest colour as panel. The gap above panel to civil wall shall be properly closed with aluminium L - angle secured properly between civil wall and panels. All the gaps between panel to panel shall be closed with GI pre coated External Flashing . All the gaps between ceiling elements and ceiling panel shall be sealed using food grade silicon sealant of the same colour as the panel. , CLEAN ROOM PANELS , Standard wall partitions are a composite construction of two skins over an GI frame work with a sealed and insulated interior. Standard panel dimensions are 1200 mm. Standard panels have an overall thickness of 80 mm.Including Silicon Sealant. The self supporting internal walls are constructed with an interior floor Flashing to suit panel thickness.The Partition seams are sealed by silicone(Food grade) with a perfectly flush finishing. The panels should be factory manufacture. , CLEAN ROOM COVINGS , Extruded Aluminum Powder Coated /Anodized clip on type covings of 60mm radius for Panel to Panel and Panel to Ceiling. , Horizontal & Vertical Coving , 3DCorner Powder Coated , 2D Corner Powder Coated , AL powder Coated TEE Support for Ceiling Panels with threaded Rods and clamps , CLEAN ROOM DOORS , Doors are designed to fit flush into the wall panel / civil walls system on both sides and are supplied in different dimensions. Doors are fabricated from Pre Coated GI sheets & Pufas infill(48 +/-2 kg./m3). Shutter has sheet thickness of 1mm and the frame of 1.2mm. jam depth of door shutter inline with adjacent panel thicknessand shutter width of 40mm. Doors are available in various sizes as per the requirement. The following accessories are a part of the door: Note: 1.All joints between view panel and door panel to be sealed usingapproved food grade silicon sealantof the same or nearest colour as the panel. 2.Colour of the door panel:Same as Panel Colour or Blue 3.Double face VHB tapes of required thickness or silicon sealant to be provided on the periphery of the view panel frame to avoid any play between view panel frame and the slot in the door leaf. , Shutter Thickness: 40 mm thick , Stainless steel hinges (Any reputed Make) , Stainless Steel D type of handles on pull side , Stainless steel push plates on push side. , Heavy duty Concealed door closure , concealeddouble glazed Vaccumized View panel along with self adhesive tape and silicon sealant (500mmWx750mmH) with toughened glass with 6mm thick and black border , Mortice dead lock (ML100D) with both Side Key Operation Cylinder-Dorset , Concealed Flush Bolt Body with rod , Gasket at bottom for Double Door , Stainless Steel kick plates on both sides of 1.2mm thick with 300mm height for material transfer doors for Double Door. , DOUBLE DOOR SIZE , 3500mm Width X 2500mm Height Door (width of each door 1800mm) , VIEW PANELS ON MODULAR PARTITION , SINGLE GLAZED , All Viewpanel units are Double glazed and round profiled Epoxy based powder coated GI wall panel system. Thickness of 6/8 mm Tougened glass. The window system is completelyof food grade Silicone sealed. All veiw panels to have black border. Approx Size of view panels will be 800 x 1000mm , View Panel on 80mm wall panel , FALSE CEILING CUTOUTS FOR ELECTRICAL & HVAC GRILSS,LIGHT FIXTURES ETC. , Frame Work for Wall Panel Cutouts , Back Boxes for Electrical Sockets includes 3M, 2M, 6M, 8M, Single Phase, Three Phase industrials sockets respectively of apprvoed makes like Anchor, MK, North West & Legrand. , Frame work for False Ceiling Cutouts for Electrical & HVAC , PVC Conduit for Electrical Cables / Data Cables 24mm dia / 40 mm dia respectively , INBUILT RETURN RAISER , Supply and Installation of wall panel inbuiltReturn Air Risers of0.8 mm thick GI sheet & G4 Filter in aluminium frame work with proper fixing arrangement & fastening using SS 304 Dome nuts. to be provided up to the top of the false ceiling for HVAC duct connection. along with Butter fly Dmpers on the Top side. , Inbuilt raiser 600 x 600 , GI RETURN AIR FILTER WITH SS PERFORATED SHEET MODULE , Supply & installation of Return Air Raisers SS PERFORATED SHEET MODULE WITH 20 MICRON FILTER ASSEMBLY TO FLUS FIT THE RETURN AIR RISER PANEL. The RA raiser shall be adequately supported to ensure the rigidity. , 450 mm x 450 mm x 450 mm , Supply and Laying ofSelf levelling Expoxy flooring with Floor Preparation work and application ofone coat primer, screed and finishing with Self levelling Epoxy up to a max of 2mm of approved Colour , INSULATED FLEXIBLE DUCT WITH NECESSARY FIXING CLAMPS ON BOTH SIDE FOR TERMINAL HEPA MODULE , Supply, Installation, Testing and Commissioning of The insulated flexible duct of class 1 air duct, light weight, strong, fully flexible & made of double lamination of films permanently bonded to a coated spring tough steel wire helix. The thermal efficiency is ensured with a blanket of fiberglass wool insulation in between. Necessary Fixing Clamp on both side shall be considered. (With Spigot Connection & Rigid GI Round Duct). Note: Rigid GI Round Duct area shall be part of GI Ducting. Each Flexible connection shall not be more than 1 Mtr. , 200 mm Dia , TERMINAL HEPA FILTER WITH MODULES , Supply, Installation, Testing and Commissioning of H14 HEPA Filterwith Housing & Damper (Bottom Discharge Module Type with SS304 perforated grille of 16 SWG sheet along with SS chain link). Complete Housing (Sides + Top) made of extruded aluminium anodized material and low leakage aluminum collar damper with operating bevel gear arrangement, Diffuser Plate,Housing shall be suitable for fixing the Gel Sealtype (Polyurethane gel) terminal HEPA filter (H-13) with Protective Expanded Metal Screen. The Filter Housing shall have provision for smoke aerosol test point and differential pressure measuring point. The filter mounting box shall have a provision to replace filter & control the airflow from inside conditioned space. The HEPA filter modules are of the following sizes: , Plenum box size of 485x485x220H (530X530mm Flange to Flange) inlet collar with Diffuser plate & TOP entry 305 Sq / dia Collar with necessary clamps completewith gel seal filter minipleat H-13 of Size: 450X450X70mmwith DOP port and bevel gear arrangement room side operation damper. , PRESSURE MONITORING SYSTEM , Supply, Installation, Testing and Commissioning of Compound Magnahelic gauges housed in a SS304 front cover (50-0-50 Pa) complete with PVC tubing and SS perforated nozzle (For Installation in Clean Room Panel for Classified Areas) , MISCELLANEOUS , Commissioning of Classified Areas with Validation reports comprising of: , AHU & Duct leakage testing with pressurization (As per SMACNA air duct leakage standards). This process to be documented. , HVAC testing adjusting and balancing as per ASHRAE standard. , Air balancing with flow hood meter , Room Temperature & Humidity mapping for 24 hours and monitoring for 3 days. , Room pressure balancing with monitoring for 3 days. , HEPA Filter Integrity Test. , Particle count test , Providing all documentation of DQ, IQ, OQ & PQ in approved formats. , The Validation has to be carried out for minimum 3 working days continuously for Air flow, Temperature and Humidity. For Room Pressure Differential continuously for 3 working days. In case of any non compliance the system has to be set right and the Validation has to be carried out once again as per the above schedule. Validation has to be carried out by valued Certification ISO 14644-1 is a widely recognized certification .Its shouldissued by the International Organization for Standardization (ISO) or The FDA, Health Canada, and the EU recognize this certification. , Clean Air Devices Equipments , Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over of personal Air shower , single entry and single exit,high velocity, low pressure system SS304 nozzles,pre and HEPA fillers, completely self contained unit, utilizing low wall return (floor grill type not accepted) , The Unit shall be consisting of ISO class 8 clean room compatible pre-fabricated units built up, in place having fluorescent lamp with acrylic cover, electronic ballast , both side red and green indicators, elector-magnetic latches on both sides of Dorma make to ensure both doors do not open simultaneously, 5.0 mm thick viewing glass,SS304 finish handles of Dorma make, door closer with hold open arm of Dorma make, blower, control wiring, emergency stop switch etc. , For 3 persons entry , Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over of stainless steel centrifugal air curtain having following specification.The product should be made up stainless steel 304Grade having 3 Blowers(in M.Steel), 2 Motors operating on three phase , Power =1650 Watt having RPM (Max/Min = 2700) and CFM. Overall Dimension of 6000X230X212(mm) with Noise level < 66 db. Air Curtain should be provided with velocity control switch and a Door sensor. The product should carry manufacturers warranty of one year from the Date of Supply. Along with Fabrication work of providing 2/1 MS Pipe , Tin Sheet as cover, Bracked and screws*Variations acceptable in parameters above - 5-10% The Product should be Supplied along with PVC curtains & SS Bracket for PVC Support. Supply, installation, testing and commissioninging of transparent blue PVC Strip curtain,these medium weight strip will help with temperature control or dust exclusion without impeding access, It is suitable for the door is the main entry gate of the premises, means exposed to air.The Product should be complete in all aspect as per Engineer incharge instructions , Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over of stainless steel centrifugal air curtain having following specification.The product should be made up stainless steel 304Grade having 2 Blowers(in M.Steel), 2 Motors operating on three phase , Power =1650 Watt having RPM (Max/Min = 2700) and CFM. Overall Dimension of 3500X230X212(mm) with Noise level < 66 db. Air Curtain should be provided with velocity control switch and a Door sensor. The product should carry manufacturers warranty of one year from the Date of Supply. Along with Fabrication work of providing 2/1 MS Pipe , Tin Sheet as cover, Bracked and screws*Variations acceptable in parameters above - 5-10% The Product should be Supplied along with PVC curtains & SS Bracket for PVC Support. Supply, installation, testing and commissioninging of transparent blue PVC Strip curtain,these medium weight strip will help with temperature control or dust exclusion without impeding access, It is suitable for the door is the main entry gate of the premises, means exposed to air.The Product should be complete in all aspect as per Engineer incharge instructions , SS/PP Furniture , Design, engineering, fabrication, supply, erection and testing of Cross over bench made up of 10 mm thick PP sheets of size which has to fully fixed in the designated placein the changeroom, with heat welding .Bottom of bench will have pegion holes for keeping dayshoes/CR sleepers of equal size 250 mm X182 mm in two rows. , Design, engineering, fabrication, supply, erection,testing and commissioning ofgarment cubicle compatible for ISO class 8 cleanroom either SS304 sheet material for keeping maximum 15 cleanroom garments including 15 sets of garments, sliding doors, glazing, UV light, Pre filter, HEPA filter and blower for recirculation of air, complete ready to use. , ELECTRICL LIGHTS AND ACCESSORIES , LIGHT FIXTURES , Supply,Installation, Testing & commissioning of following LED light fittings for lighting fixture with accessories and LED chip. The Luminaire shall be with CRCA housing and Luminaire and an operating Voltage Range of 120 - 277V, Internal Surge Protection 2.5KV. , 40W 2x2 (600mmx600mm) LED Screw less Clean room recess mounted bottom opening luminaires with toughed glass with diffused acrylic cover, construction of the housing with engineering push back mounting arrangement system of Approved make. System output 4000 lumens to be considered.(Philips or equivenlant) , Electrical Cabling with PVC Conduiting for the Lights 3 Core1.5 Sqmm , POWER SOCKETS , Supply, Installation, Testing & Commisioning of following Plug sockets & Push buttons. The assembly shall be housed in metal box / on partition / on wall concealed type. Rate shall include the internal wiring, terminations, GI back box and front face plate, enclouser with fixing accessary like lugs, screws, blot nuts, ferruls etc. as per tender technical specifications.Necessary wall chipping, drilling & fixing of back box in concelead type. Rate shall be included backbox fixing concelead on the walland chipping along the wall fixing chicken mesh and making good surface of wall as required at site. Note : Modular sockets Back box should be considered 45mm depth only. , Emergencystop push button station with enclosure fixed on wall or on required MS angle support with all its accessories of approved make. , EARTHING , GI Plate Earthing , Supply and Laying of following earthing strips / earth wire of the following sizes with required accessories like clamps,bolts & nuts, painting. Two numbers of earth strips should run along with cable tray/civil wall with proper using bolt and nuts for strips connectivity and two earth points shall be end terminated for all equipments, motors, all Electrical and ELV panels, DB etc., refer the earthing schematic for considering the earth strips. , 50mmx6mm GI Strip , DRAIN PIPE , Supply & Installation ofPVC drain pipe insulated with 9 mm thick closed cell FM approved class O nitriler rubber insulation. Necessary U trap for units with clean out plugs to be provided , 40mm dia , Sheet Metal Work usingFactor Fabricated Duct with Ductmate (TDF) Flanges for all sizes of the duct. Fabrication as per SMACNA Standards , Galvanizing shall be Class VIII – light coating of zinc, nominal 120 gm / sqm surface area and Lock Forming Quality prime material alongwith mill test certificates.In addition, if deemed necessary, samples of raw material, selected at random by owner’s site representative shall be subject to approvaland tested for thickness and zinc coating at contractor’s expense. , All duct construction and installation shall be in accordance with SMACNA standards.In addition ducts shall be factory fabricated utilizing the following machines to provide the requisite quality of ducts. , All ducts shall be fabricated and installed in workmanlike manner, conforming to relevant SMACNA codes. , To ensure the air tightness, all ducts shall be checked with Duct pressure Test after completion of duct installation but before applying insulation , Guide vanes to be installed in elblow, reducers and other accessories , Stiffernner to be considered for ducts with more than 1200mm wide ducts , Duct joining shall completed with adhesive type gasket and sealant , All ducts needs to properly supported with suitablewire supports as per makes given in make list. The cost shall be inclusive of anchor fastners/wedge supports suiting to steel structure. , With all necessary accessories i.e fixing etc complete. , Rectangular Ducting , Sheet Metal Ducting As per Specification. Pressure 500 Pa , 24 G Ducting with Factor Fabricated Duct/ TDF flanges , 22 G Ducting with Factor Fabricated Duct/ TDF flanges , 20 G Ducting with Factor Fabricated Duct/ TDF flanges , Thermal & Acoustic insulation , Thermal Insulation for ducts , Supply, installation and testing of Class- O, 25 mm thick Closed cell elastomeric insulation for thermal insulation for indoor supply air ducts with density not less than 50 kg / cum. Microban antimicrobial protection insulation material to be fire retardant. Joining tapes & low VOC adhesive to be supplied with the insulation material by the insulation material manufacturer. , Supply, installation and testing of Class- O, 19 mm thick Closed cell elastomeric insulation for thermal insulation for indoor supply air / return air ducts with density not less than 50 kg / cum. Insulation material to be fire retardant. Joining tapes & low VOC adhesive to be supplied with the insulation material by the insulation material manufacturer. , Supply, installation and testing of Class- O, 13 mm thick Closed cell elastomeric insulation for thermal insulation for indoor supply air / return air ducts with density not less than 50 kg / cum. Insulation material to be fire retardant. Joining tapes & low VOC adhesive to be supplied with the insulation material by the insulation material manufacturer. Refer method statement in technical specification for insulation works. , Acoustic Insulation for ducts , Supply, transportation , Lifting , Shifting ,installation ,testing and commissioning of Acoustic insulation for ducting with 50mm TF quality thermocole, density 18kg/cum, chicken wire mesh and 2 coats of 12mm thick sandcement plastering for exposed ducting. , Air Terminal Devices , Supply, installation, testing and balancing Powder Coated extruded aluminium grilles with collar damper for supply and return distribution(colour for the grill to be confirmed by department before placing theorder) . Deflection of the grille shall be 0 / 15 / 30. same will be confirmed later. Single / 2 way / 4 way deflection shall be confirmed later. , Supply, Fixing, Testing and commissioning of Aluminium powder coated4-Way Diffusers with Anti smudge ring and all fixing accesseroies as per standard specifications and practice. , Supply, installation and testing ofJet diffuserwith fire resistance flexible double canvas Connection for supply distribution(colour for the Jet to be confirmed by consultant/ PMC team before placing theorder) , Ø 315 , Supply and fixing of 18G circular butterfly damper with provision to fix to the rectangular duct with GI circular flanges. , Supply and fixing of Insulated Aluminum flexible duct with 25mm thick glass wool insulation covered with aluminum foil suitable to connect the ducting including necessary clamps at both ends of size , Acoustic Insulation for AHU rooms , Supply, installation and testing of acoustic insulation on walls & ceilings for the AHU Rooms with 50mm thk. 24 kg/ cum density Resin bonded fiber glass covered with 24 G GI perforated sheet as per specification. The FG slabs shall be placed in the grid of 600mmx600mm centers formed out of GI channels. , Supply and Fixing of Fresh Air / Exhaust air Louvers with brass wire mesh backing with Pre filter along with Dampers for all AHU room fresh air wall openings. , Supply, installation and testing of Factory fabricated Rectangular shape - GI Volume control dampers, 1.6-mm GI Steel Frame, 1.6-mm GI blades, 150-mm width, with required hardware and accessories. Stiffen damper blades for stability. Include locking device to hold single-blade dampers in a fixed position without vibration & engraved marking on position of damper. , Supply, installation and testing of Aluminium powder coated fresh air intake / exhaust air louvers backing with pre filters complete with HDPE insect mesh with cowl mounting frame and 45 deg angle suitable for protection against splashing rain water fixed in a powder coated Aluminium angle mount frames as required for all AHU ROOM fresh air wall openings. , Supply, installation and testing of Motorized Fire dampers (MSFD) with ON/OFF type actuator. The dampers to be fire rated for 120 minutes at 250Deg C. Fire damper to be provided with matching flanges on both sides. Fire dampers should be supplied with extended fire rated sleeves. Actuators shall be for spring return type & shall be fire rated for 120 minutes @ 120Deg C. Actuators to be internally mounted. Actuators should be suitable for BMS connectivity with necessary accessories. , Note:Duly factory fitted and tested at manufacturers works and certificate to this effect produced along with delivery of fire damper. , Fire damper , Actuator,Sensor,Control panel and relay/communication module, interlinking cabling , Supply, installation and testing ofGI Non ReturnDampersat suction & discharge side, suitable for duct mounted including mating galvanized angular iron flanges. , Supply, Installation, Testing and Commissioning of Fire Retardant Canvass Connections with MS Eoxy painted / Al powdercoated finish angle flanges on both sides as per the specifications and approved drawings. , Supply, installation, testing and commissioning of FM approved 32mm thickness of closed cell nitrile rubber without aluminium foil temperature range from -10ºC to +60ºC, Class O fire category and as per specification.for Underdeck insulation, as per technical specifications and as shown in approved drawings. Adhesive shall be used as recommended by insulation manufacturer for applying over concrete structures and it shall be green building complaint. Makes: Galaxy, sheth insulation, ALP Aeroflex,neothermalinsulation. , MS structural Steel for supports ofUnit, Piping, Control cabling supports including fabrication,erection with GI clamps and brackets with adequate number of supports for pipes every 2.5 mts interval and at bends for Insulated refrigerant pipe for exposed areas etc , FALSE CEILING WORK , Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre,shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. , wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint , all as per manufacturers specification and also including the cost of making openings for light fittings, grills,diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : (a)12.5 mm thick tapered edge gypsum moisture resistant board. (Make : Gproc , L Strong , Armstrong) , ELECTRICAL WORKS: , MV Panels VRF/VRV OUTDOOR PANNEL-1 , Supply, installation,Testing and Commissioning of 3 phase and Neutral 415V, 4 wire Free Standing Floor mounted MV panel made out of 14 SWG MS sheet after seven tank process and painting with Epoxy powder coating. , The panel shall consist of suitable rating TPN Aluminium busbar (at the rating of 0.8A/Sq.mm) supported with DMC/ SMC barriers and color coded with Heat shrinkable sleeves. , The Metering shall be provided as specified. The panel shall have Short circuit withstanding capacity of minimum 50KA and consist of the switchgear as mentioned below. , The panel shall be got fabricated from manufacturers with CPRI Test certificate only. The PCC shall have at least two spare cubicles of the maximum rating. The size of all Panel Mounting Meters shall be 96X96mm. , The Panels shall be mounted on U channels including supply and fixing of the same. Every ACB shall be provided with ON/OFF /Trip Indication lamps of LED type. For all Electrically operated Breakers, Local Remote Selector switches shall be provided for controlling the Breakers remotely. , M.V.PANEL ( OUTDOOR ) -VRF OUTDOOR UNIT , Incoming : 800A FP 50KA EDO ACB with Microprocesser Based releases for Overload, S/Cand earth fault- 1 set , BUSBARS : 800A, TPN Aluminium busbars – 1set , Metering for Incomer , Phaseindicating lamps - 1 set withtoggle switch , Voltmeter (0-500V) with selector switch - 1 set , Ammeter (0-800A) with selector switch - 1 set , Multifunction Meter -1Set , 800/5A, CL-1, 15VA CTs with resin cast- 3Nos. , Outgoing Feeders :- , 63A TP 16KA MCCB As Outgoing Feeder - 18 Nos , Earth bus bar with GI Strip , MV Panels VRF/VRV OUTDOOR PANNEL-2 , Supply, installation, Testing andCommissioning of 3 phase and Neutral415V 4 wire Free Standing Floor mounted outdoor type weather proof double door with canopy on top MV panel made out of 3mm thick CRCA/Galvanised steel enclosurefor main frame and 2mm thick partitions for mechanical strength/ruggedness, after seven tank process and painting with Epoxy powder coating. The panel shall consist of suitable ratingTPN Aluminium busbar (at the rating of 0.8A/Sq.mm) supported with DMC/ SMCbarriers and color coded with Heat shrinkable sleeves. The Metering shall beprovided as specified. The panel shall have Short circuit withstanding capacity of minimum 50KA and consist of the switchgear as mentioned below. Outdoor panels shall have IP-55 degree of protection wiith external door . Enclosure shall be modular with bolted design. Enclosure shall be powder coated with RAL-7035 coat with matt finish. Design ambient temperature shall be 50 degree centrigrade. No use of hygroscopic material like FRP/Hylam/Bakellite sheet inside the panel for partitions or any other purpose. , The PCC shall have at least twospare cubicles. The size of all Panel Mounting Meters shall be 96X96mm. The Panels shall be mounted on U channels including supply and fixing of the same. Every ACB shall be provided with ON/OFF /Trip Indication lamps of LED type. For all Electrically operated Breakers, Local Remote Selector switches shall be provided for controlling the Breakers remotely.ACBs shall have built-inAll ACBs shall be provided with Digital type Ammeter of suitable range along with CTs. All ACBs shall be provided with ON/OFF/TRIP indication lamps and shunt trip coils. All MCCB/ACBs of rating 160Aand above shall be with Micro processor releases All MCCBs below 160A shall be with adjustable thermal magnetic based releases. All MCCBs shall be with spreader links and rotary handle. All MCCBs shall be over load & short circuit releases withIcu=100% Ics. All CTs/CBCT shall be resin cast type. All Controlling wiring shall be FRLS cables, all the bus bar sleeves shall be Heat shrinkable kits.Panels shall have form 4b/form 3b construction as per the requirement. ACBs shall conform to IEC 60947 (part 1&2), shall be suitable for rated system voltage 690V, Insulation voltage 1000V and Impulse withstand of 12KV. , For MCCB with Microprocessor based release : A common indication LED for internal temp/ fault/alarm . MCCB should have in-built feature of logical selectivity by which it can give a time delay of 50msec between upstream and downstream MCCB The microprocessor based release should have the following settings: • Overload Settings: 0.4 to 1 times of Ir • Short Circuit Settings: 1.25 to 10 times of Ir. • Earth fault Settings: 0.2 to 1 times of In. • Neutral protection settings: 0 – 50% – 100%Ir. • Manually closing mechanism should be accommodated in a Moulded housing of robust and vermin-proof construction. • MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open) • The tripping devices shall be ambient temperature compensated type. The insulating case shall be made of high strength heat resistant and flame retardant thermosetting insulating material. , OUTDOOR MAIN PCC PANEL , Incoming : , Incoming : 800A FP 50KA EDO ACB with Microprocesser Based releases for Overload, S/Cand earth fault- 1 set , Busbars :800A TPN Aluminiumbusbars - 1 set , Outgoings : , 63A TPN, 16kA,Moulded Case Circuit Breakerand Electromagnetic based protection release having adjustable over load, short circuit and earth fault protection.- 20 No. , Metering : , 0-500V Digital Voltmeter withselector switch and Fuses - 2 sets , 0-800A Digital Ammeter with CTs ofratio 800/5A,Class 1 Accuracy and15VA burden and selector switch - 2sets , LED Phase indication lamps with individuals Fuses and control withtoggle switches- 2sets , CT Operated Load Manager with RS 485 port ( Similar to EM-6400) – 2sets , Suitable Earth strip at bottom of the panel of GI Strip , Supply, Installation, Testing and Commissioning of following size 1.1 KV Grade Aluminum / Copper conductor XLPE insulated PVC sheathed armoured cable and shall be laid on cable traywith all installation materials. the cable shall conform to IS 7098 / part-I. , 4Core X 10Sqmm (Copper)(Armoured) (for 20HP ODU ) - 27Nos , 4Core X 10Sqmm (Copper)(Armoured) (for 28TR AHU ) - 1Nos , 4Core X 6Sqmm (Copper)(Armoured) (for 8KW HEATER ) - 1Nos , 4Core X 16Sqmm (Copper)(Armoured) (for 52TR AHU ) - 1Nos , 4Core X 10Sqmm (Copper)(Armoured) (for 12KW HEATER ) - 1Nos , 4Core X 16Sqmm (Copper)(Armoured) (for 42TR AHU ) - 4Nos , 4Core X 10Sqmm (Copper)(Armoured) (for 15KW HEATER ) - 4Nos , Supply, Installation, Testing and Commissioning of following size ELECTRICAL TERMINATIONS WITH SINGLE COMPRESSION GLANDS / LUGS: , 4Core X 10Sqmm (Copper)(Armoured) (for 20HP ODU ) - 27Nos , 4Core X 10Sqmm (Copper)(Armoured) (for 28TR AHU ) - 1Nos , 4Core X 6Sqmm (Copper)(Armoured) (for 8KW HEATER ) - 1Nos , 4Core X 16Sqmm (Copper)(Armoured) (for 52TR AHU ) - 1Nos , 4Core X 10Sqmm (Copper)(Armoured) (for 12KW HEATER ) - 1Nos , 4Core X 16Sqmm (Copper)(Armoured) (for 42TR AHU ) - 4Nos , 4Core X 10Sqmm (Copper)(Armoured) (for 15KW HEATER ) - 4Nos , SITC of GI Earthing for equipment , 8 SWG G.I. Wire , SUBHEAD-IVX : POWER WIRING : , Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powderpainted including earthing etc. as required. (But without MCB/RCCB/Isolator) , 12 way (8 + 36), Double door , 8 way (8 + 24), Double door , Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuitbreaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. , 63A , Supplying and fixingof 6A to 32A rating 240/415V,10kA , C Curveminiature circuit breaker suitable for inductive load of following polesin the existing MCB DB complete with connections ,testing and commissioning etc complete. , Single Pole , Supplying and fixing following way, vertical type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powderpainted including earthing etc. as required. (But without MCB/RCCB/Isolator) , 12 way (4 + 24), Double door , 8 way (4 + 24), Double door , Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, molded case circuitbreaker (MCCB), having a breaking capacity 25 KA in the existing MCB DB complete with connections, testing and commissioning etc. as required. , 200A 4P MCCB, 35 kA , Supplying and fixingof following rating 240/415V,10kA , C Curveminiature circuit breaker suitable for inductive load of following polesin the existing MCB DB complete with connections ,testing and commissioning etc complete. , 63A Three Pole MCB 16 kA , Supply,erection,testing and commissioning of the following switchsockets with anodised G.I. Box,front plate and fixing screws etc . , 6/16 Amps, 5-pin (250 Volts) single phase modular type socket controlled by 16 Amps SP Switch. , Supply and fixing of factory made 20A, 1Ph Metalclad socket with plugtop &20A SPMCB in MS box including all fixing accessories , Supply and fixing of factory made 25A, 1Ph Metalclad socket with plugtop &25A SPMCB in MS box including all fixing accessories , Supplying and fixing 32A, 415V, TPN industrial type socket outlet with 4 pole and earth metal enclosed plug top alongwith 32A C Curve, TP MCB in sheet metal enclosure on surface/recess with chained metal cover for the socket outlet and complete with connections ,testingand commissionining etc complete as required. , Supplying and fixing 63A, 415V, TPN industrial type socket outlet with 4 pole and earth metal enclosed plug top alongwith 63A C Curve, TP MCB in sheet metal enclosure on surface/recess with chained metal cover for the socket outlet and complete with connections, testingand commissionining etc complete as required. , Supply,erection,testing and commissioning of the following switchsockets with anodised G.I. Box, Stainless steel front plate and fixing screws etc . , 6/16 Amps, 5-pin (250 Volts) single phase modular type socket controlled by 16 Amps SP Switch. , Supply and Wiring with the following size 1100V grade PVC insulated multistrand, FRLS Copper conductor wires in and includingsuitable size heavy gauge PVC conduit concealed in wall / Ceiling including all accessories such as junction boxes, bends, elbows including end terminated with suitable lugs. , 2runs of 4Sq.mm wires with 1run of 4 Sq.mm wireinand including 25mm diaPVC Conduit(For 16A Sockets). , 2runs of 6Sq.mm wires with 1run of 6 Sq.mm wireinand including 25mm diaPVC Conduit(For AC Sockets). , 4runs of 10Sq.mm wires with 2run of 6 Sq.mm wireinand including 25mm diaPVCConduit. , 4 X 16 sq. mm + 2 X 16 sq. mm earth wire in existin PVC / Floor raceways , Supply and Wiring with the following size 1100V grade PVC insulated multistrand, FRLS Copper conductor wires in existingMS/PVC conduit / Floor race way including all necessary interconnections etc complete. , 2runs of 2.5Sq.mm wires with 1run of 2.5 Sq.mm wire in existingPVC Conduit(For 6A Sockets & Switch boards),ferrules incliding all labour charges etc., complte.. , 2runs of 4Sq.mm wires with 1run of 4 Sq.mm wiresin existingPVC Conduit(For 16A Sockets), ferrules incliding all labour charges etc., complte.. , 2runs of 6Sq.mm wires with 1run of 6 Sq.mm wiresin existing PVC Conduit(For AC Sockets), ferrules incliding all labour charges etc., complte.. , 4runs of 6Sq.mm wires with 2run of 6 Sq.mm wiresin existing PVC Conduit. for run of mains, ferrules incliding all labour charges etc., complte. , 4runs of 10Sq.mm wires with 2run of 6 Sq.mm wireinexistingPVCConduit.for run of mains, ferrules incliding all labour charges etc., complte. , 4 X 16 sq. mm + 2 X 16 sq. mm earth wire in existin PVC / Floor raceways for run of mains, ferrules incliding all labour charges etc., complte. , Providing and fixing of maintenance free earthing which consists of 40mm Dia, standard length (as per Equipment Supplier) electrode capsule,filled with earth enhancing compound,sealed at both ends and brazed lead for connection at one end suitable for direct installation at site at a depth of 2.5 mtr.Earth enhancingcompound upto a depth of 2.0 mtr around the electrode capsule and also wih brick chamber and cast Iron cover etc complete including excavation in all types of soil. , Supply and laying of following size strips including all necessary inter connections with earth station and equipments , 50 X 5 mm Hot dip GI strip , 25 X 5 mm Hot dip GI strip , Supplying and laying 6 SWG G.I. wire at 0.50 meter below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. , Supply and fixing of following size GIPerforated type cable tray made out of 2mm thick G.Isheet including MS supports for fixing the tray, anchor fasteners etc., laid including 2runs of 25x5 GI strip etc including with 2 mm thickGI covers. , 300 mm widex 50 mm Height , 150 mm widex 50 mm Height , 100 mm widex 50 mm Height , Supply, laying, jointing GI pipes of medium quality including specials of approved make fixed to wall/to the required lengths, threading jointing chasing the walls and floor, making holes, clamping of clamps and making good the same, necessary excavation, etc., complete as specifed and directed. , 50mm Dia , SUBHEAD-XV : SHOP ELECTRIC: , Supplying and fixing 20A, 415V, TPN industrial typesocket outlet with 4 pole and earth metal enclosed plug top alongwith 20A C Curve,4 P MCB in sheet metal enclosure on surface/recess with chained metal cover for the socket outlet and complete with connections ,testingand commissionining etc complete as required. , Supplying and fixing 32A, 415V, TPN industrial type socket outlet with 4 pole and earthalongwith 32A C Curve, TP MCB in sheet metal enclosure on surface/recess with chained metal cover for the socket outlet and complete with connections ,testingand commissionining etc complete as required. , Supplying and fixing 63A, 415V, TPN industrial type socket outlet with 4 pole and earthalongwith 63A C Curve, TP MCB in sheet metal enclosure on surface/recess with chained metal cover for the socket outlet and complete with connections ,testingand commissionining etc complete as required. , Supply, testingand commissioning of following size 1.1KV grade XLPE insulated armoured aluminium conductor cable. The cable shall conform to IS 7098/ Part-II. , 4C X 10Sq.mm , 4C X 16Sq.mm , 3.5C X 25Sq.mm , 3.5C X 35Sq.mm , 4C X 50Sq.mmCu Armoured Cable , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. , Upto 35 sq. mm , Above 35 sq. mm and upto 95 sq. mm , Above 95 sq. mm and upto 185 sq. mm , Above 185 sq. mm and upto 400 sq. mm , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. , Upto 35 sq. mm , Above 35 sq. mm and upto 95 sq. mm , Above 95 sq. mm and upto 185 sq. mm , Above 185 sq. mm and upto 400 sq. mm , Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. , Upto 35 sq. mm , Above 35 sq. mm and upto 95 sq. mm , Above 95 sq. mm and upto 185 sq. mm , Above 185 sq. mm and upto 400 sq. mm , Providing Indoor ordinary end terminations for thefoollwing 1.1 KV grade XLPE insulated armoured alluminium conductor cables with compression type steel gland, Bi-metallic lugs using crimping tool, Insulation tape, Identification tags etc., including end termination and Earthing of Gland with 8SWG GI Wire. , 4C X 10Sq.mm , 4C X 16Sq.mm , 3.5C X 25Sq.mm , 3.5C X 35Sq.mm , 4C X 50Sq.mmCu Armoured Cable , Supply and fixing of following size GIPerforated type cable tray made out of 2mm thick G.Isheet including MS supports for fixing the tray, anchor fasteners etc., laid including 2runs of 25x5 GI strip etc including with 2 mm thickGI covers. , 600 mm widex 50 mm Height , 450 mm widex 50 mm Height , 300 mm widex 50 mm Height , 150 mm widex 50 mm Height , Providing and fixing of maintenance free earthing which consists of 40mm Dia, standrad length (as per Equipment Supplier) electrode capsule,filled with earth enhancing compound,sealed at both ends and brazed lead for connection at one end suitable for direct installation at site at a depth of 2.5 mtr.Earth enhancingcompound upto a depth of 2.0 mtr around the electrode capsule and also wih brick chamber and cast Iron cover etc complete including excavation in all types of soil. , Supply and laying of following size strips including all necessary inter connections with earth station and equipments. , 50 X 5 mm Hot dip GI strip , 25 X 5 mm Hot dip GI strip , Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. , Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCBdistribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs andincomer ) as required . (Note : Vertical type MCB TPDB isnormally used where 3 phase outlets are required.) , 12 way (8 + 36), Double door , Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuitbreaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. , 250 A, 35KA 4P MCCB , 200 A, 35KA 4P MCCB , 63 A, 4P RCBO , 100 A, 4P ,25ka MCCB ( , 125 A, 4P ,25ka MCCB ( , Supply,Installation Testing Commissioning of following TTA PANEL.Supply, erection, testing and commissioning of 415V, 3 phase 4 wire 50 c/s Main LT Panel at Substation fully compartmentalized cubical type, as per the standards IEC61439-1&2 as tested assembly (TTA) ,tested for impulse voltage 8 KV,IP 42 fabricated CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having required capacity extensible type FP bus bars of high conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 35KA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, Form of separation shall be form 4b with metallic separation only entire panel shall have a common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of bus bars, interconnection, interlocking between feeders etc.,with indication lamps, push buttons necessary accessories, complete with following incoming and outgoing switchgears with protection and metering etc. as per specification and schematic diagram including provision to be made for interfacing with BMS etc. complete as required, with incoming & outgoing cable entry from bottom/top and bus-duct entry from top, wiring with 2.5sq. mm. FRLS insulated copper conductor , cable alleys, PLC cable gland i/c providing following switch gears , All ACBs should have Ics=Icu=Icw for 1 sec All MCCBs shall be rating for 25kA (Ics=Icu). All MCCBs above 63A should be provided with Copper Spreader Terminals Marshalling Bay To Be Provided for BMS Operation Approval shall be taken for each panel before fabrication. PLC based control with 100% hot redundant PLC arrangement with touch-screen LCD / LED display board (min. 8 Diag size)along with all accessories for complete automatic, manual andHMI controls & indication. Energy Management Software wth necessary cabling shall be in scope, nos. of breaker / Meters to be connect with energy management software shall be inform by Engineer In Charge. , USER EQUIPMENT PANEL , Incomer , 630 A, 50KA, 4P , ACB, Should be supplied with Microprocessor basedS/C, E/F, O/CProtection.(70 - 100% Plug setting) – 1No , 2A, controlMCB - 3 Nos. , Outgoings : , 200A ,35KA TP, MCCBs - 9 Nos , 125A ,25KA TP, MCCBs - 3 Nos , 100A ,25KA TP, MCCBs - 3 Nos , 63A ,16KA TP, MCCBs - 3 Nos , Surge Protection Device - 1 No , Bus Bar : 630 A TPN Alluminium Bus Bar-1 Set , MeteringIncomer : , 0-500V Digital Voltmeter with selector switch andMCB-1set , CT Operated Load Manager (similar to EM-6400) - 1 No , 0-630A Digital Ammeter with resin cast CTsof ratio 630/5A Class 1 Accuracy and 15VA burden and selector switch -1set , LED phase indication lamps with toggle switch -1set , Main LDB , Incomer , 250 A, 35KA, 4P , MCCB, Should be supplied with Microprocessor basedS/C, E/F, O/CProtection.(70 - 100% Plug setting) – 1No , 2A, controlMCB - 3 Nos. , Outgoings : , 160A ,35KA TP, MCCBs - 5 Nos , 63A ,16KA TP, MCCBs - 2 Nos , Surge Protection Device - 1 No , Bus Bar : 250 A TPN Alluminium Bus Bar-1 Set , MeteringIncomer : , 0-500V Digital Voltmeter with selector switch andMCB-1set , CT Operated Load Manager (similar to EM-6400) - 1 No , 0-250A Digital Ammeter with resin cast CTsof ratio 250/5A Class 1 Accuracy and 15VA burden and selector switch -1set , LED phase indication lamps with toggle switch -1set , Main PDB , Incomer , 630 A, 50KA, 4P , MCCB, Should be supplied with Microprocessor basedS/C, E/F, O/CProtection.(70 - 100% Plug setting) – 1No , 2A, controlMCB - 3 Nos. , Outgoings : , 200A ,35KA TP, MCCBs - 5 Nos , 63A ,16KA TP, MCCBs - 2 Nos , Surge Protection Device - 1 No , Bus Bar : 630 A TPN Alluminium Bus Bar-1 Set , MeteringIncomer : , 0-500V Digital Voltmeter with selector switch andMCB-1set , CT Operated Load Manager (similar to EM-6400) - 1 No , 0-630A Digital Ammeter with resin cast CTsof ratio 630/5A Class 1 Accuracy and 15VA burden and selector switch -1set , LED phase indication lamps with toggle switch -1set , COMPRESSOR PANEL , Incomer , 250 A, 35KA, 4P , MCCB Should be supplied with Microprcessor basedS/C, E/F, O/CProtection.(70 - 100% Plug setting) – 1No , 2A, controlMCB - 3 Nos. , Outgoings : , 160A ,25KA TP, MCCBs – 3 Nos , 63A ,16KA TP, MCCBs - 1 Nos , 40A ,16KA TP, MCCBs - 1 Nos , Surge Protection Device - 1 No , Bus Bar : 250 A TPN Alluminium Bus Bar-1 Set , MeteringIncomer : , 0-500V Digital Voltmeter with selector switch andMCB-1set , CT Operated Load Manager (similar to EM-6400) - 1 No , 0-250A Digital Ammeter with resin cast CTs of ratio 250/5A Class 1 Accuracy and 15VA burden and selector switch -1set , LED phase indication lamps with toggle switch -1set , SUBHEAD-XVI :TELEPHONE AND LAN : , Supply and laying of 25mm dia, 16 SWG black enamelled M.S. conduit concealed in wall/ ceiling/ floor including all accessories such as junction boxes, conduit bends, etc., complete as required for Telephone etc., , Supply and laying of 25mm dia, heavy gaugePVC . conduit concealed in wall/ ceiling/ floor including all accessories such as junction boxes, conduit bends, etc., complete as required for Telephone etc., , Supply and laying of 25mm dia, heavy gaugePVC . conduit concealed in wall/ ceiling/ floorand drawing of 12 SWG GI Wireas fish wire for laying of LAN Cables at a later stage and supply of all fixingaccessories such as junction boxes, conduit bends, etc., complete as required. , Supply and fixing of Telephone outlet (RJ11) with anodised GI box with front plate and fixing screws. , Supply,Installation,Testing and commissioning ofRJ 45 socket(FOR LAN) with flush mounting G.I. box, with front plate and fixing screws etc complete. , Supply and laying of 2pair 0.5mm dia PVC insulated Copper conductor Telephone wireconforming to DOT Specifications in already laid PVC Conduit including necessary interconnections. , Supply and laying of Cat 6 LAN cable conforming to DOT Specifications in already laid PVC Conduit Floor Race way including necessary interconnections. , Supply and laying of 10 Pair0.5 sqmm armoured copper conductor cable cable conforming to DOT Specifications in existing cable trench /Floor Race way including necessary interconnections. , Supply and installation of100 pair Krone connectors inMS junction box complete as required. , Supply and installation of50 pair Krone connectors inMS junction box complete as required. , Supply and installation of20 pair Krone connectors inMS junction box complete as required. , Supply, laying, jointing GI pipes of medium quality including specials of approved make fixed to wall/to the required lengths, threading jointing chasing the walls and floor, making holes, clamping of clamps and making good the same, necessary excavation, etc., complete as specifed and directed. , 50mm Dia , SUBHEAD-XVII :UPS WIRING : , Supply and fixing of2 Nos of 6/16A, 5Pin Socket outlet with 2Nos ofswitch of 16A ratingincluding Modular G.I Box, Front Plate and also including all fixing accessories etc complete. ( For UPS Socket) , 6/16 Amps, 5-pin (250 Volts) single phase modular type socket controlled by 16 Amps SP Switch including Modular G.I Box, Front Plate and also including all fixing accessories etc complete. , Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCBdistribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs andincomer ) as required . (Note : Vertical type MCB TPDB isnormally used where 3 phase outlets are required.) , 4 way (4 + 12), Double door , Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, molded case circuitbreaker (MCCB), having a breaking capacity 25 KA in the existing MCB DB complete with connections, testing and commissioning etc. as required. , 200A 4P MCCB, 35 kA , Supplying and fixingof following rating 240/415V,10kA , C Curveminiature circuit breaker suitable for inductive load of following polesin the existing MCB DB complete with connections ,testing and commissioning etc complete. , 63A 4P MCB 10 kA , 63A TPN MCB 10 kA , Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powderpainted including earthing etc. as required. (But without MCB/RCCB/Isolator). , 8 way (8 + 24), Double door , Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuitbreaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. , 63 A , Supplying and fixingof 6A to 32A rating 240/415V, 10kA, C Curveminiature circuit breaker suitable for inductive load of following polesin the existing MCB DB complete with connections, testing and commissioning etc complete. , Single Pole , Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copperconductor, single core cable in surface/ recessed medium class PVC/MS/Floor race wayas required including necessary interconnections etc complete. , 2runs of 4Sq.mm wires with 1run of 4 Sq.mm wire , 4Runs X 10 sq. mm + 2 X 6 sq. mm earth wire in existing PVC / Floor raceways /MS Conduit , 4Runs X 16 sq. mm + 2 X 10 sq. mm earth wire in existing PVC / Floor raceways , Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt asrequired including excavation in all types of soil. , Supplying and laying following copper strip at 0.50 metre below ground as strip earth electrode, includingconnection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets(Jointing shall be done by overlapping and with 2 setsof brass nut bolt & spring washer spaced at 50mm). , 25 mm X 5 mm copper strip , 50 x 5 mm copper stripbelow ground. , Supply and Installationof 300 x 38 mm heightG.I Floor raceway including supply and installation ofJunction Boxes ,bends and fixing accessories etc complete.The scope also includes civil work for installation of Raceways i.e chipping of flooe wherever required and also laying of sand and cement mortar for alignment of Floor raceways etc complete.The minimum thickness of the floor raceways and junction boxes shall be 2 mm (Make : Legrand ) , Supply and Installationof 150 x 38 mm heightG.I Floor raceway including supply and installation ofJunction Boxes ,bends and fixing accessories etc complete.The scope also includes civil work for installation of Raceways i.e chipping of flooe wherever required and also laying of sand and cement mortar for alignment of Floor raceways etc complete.The minimum thickness of the floor raceways and junction boxes shall be 2 mm (Make : Legrand ) , Supply,Installation Testing Commissioning of following TTA PANEL.Supply, erection, testing and commissioning of 415V, 3 phase 4 wire 50 c/s Main LT Panel at Substation fully compartmentalized cubical type, as per the standards IEC61439-1&2 as tested assembly (TTA) ,tested for impulse voltage 8 KV,IP 42 fabricated CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having required capacity extensible type FP bus bars of high conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 35KA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, Form of separation shall be form 4b with metallic separation only entire panel shall have a common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of bus bars, interconnection, interlocking between feeders etc.,with indication lamps, push buttons necessary accessories, complete with following incoming and outgoing switchgears with protection and metering etc. as per specification and schematic diagram including provision to be made for interfacing with BMS etc. complete as required, with incoming & outgoing cable entry from bottom/top and bus-duct entry from top, wiring with 2.5sq. mm. FRLS insulated copper conductor , cable alleys, PLC cable gland i/c providing following switch gears All ACBs should have Ics=Icu=Icw for 1 sec All MCCBs shall be rating for 25kA (Ics=Icu). All MCCBs above 63A should be provided with Copper Spreader Terminals Marshalling Bay To Be Provided for BMS Operation Approval shall be taken for each panel before fabrication. PLC based control with 100% hot redundant PLC arrangement with touch-screen LCD / LED display board (min. 8 Diag size)along with all accessories for complete automatic, manual andHMI controls & indication. Energy Management Software wth necessary cabling shall be in scope, nos. of breaker / Meters to be connect with energy management software shall be inform by Engineer In Charge. , UPS INPUT PANEL INDOOR , Incomer , 200 A, 35KA, 4P, MCCB Should be supplied with S/C, E/F, O/CProtection.(70 - 100% Plug setting) – 1No , 2A, controlMCB - 3 Nos. , Outgoings : , 100A ,25KA 4P, MCCBs - 3 Nos , Surge Protection Device - 1 No , Bus Bar : 200 A TPN(100%)Alluminium Bus Bar-1 Set , MeteringIncomer : , 0-500V Digital Voltmeter with selector switch andMCB-1set , CT Operated Load Manager (similar to EM-6400) - 1 No , 0-200A Digital Ammeter with resin cast CTsof ratio 200/5A Class 1 Accuracy and 15VA burden and selector switch -1set , LED phase indication lamps with toggle switch -1set , UPSOUTPUT PANEL INDOOR , Incomer , 200 A, 35KA, 4P , MCCB, Should be supplied with S/C, E/F, O/CProtection.(70 - 100% Plug setting) – 1No , 2A, controlMCB - 3 Nos. , Outgoings : , 63A ,10KA 4P, MCCBs - 5 Nos , Bus Bar : 200 A TP+NAlluminium Bus Bar-1 Set , MeteringIncomer : , 0-500V Digital Voltmeter with selector switch andMCB-1set , CT Operated Load Manager (similar to EM-6400) - 1 No , 0-200A Digital Ammeter with resin cast CTsof ratio 200/5A Class 1 Accuracy and 15VA burden and selector switch -1set , Surge Protection Device - 1 No , Supply, testingand commissioning of following size 1.1KV grade XLPE insulated armoured aluminium conductor cable. The cable shall conform to IS 7098/ Part-II. , 4C X 50Sq.mmCu Armoured Cable , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. , Above 35 sq. mm and upto 95 sq. mm , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. , Above 35 sq. mm and upto 95 sq. mm , Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. , Above 35 sq. mm and upto 95 sq. mm , Providing Indoor ordinary end terminations for thefoollwing 1.1 KV grade XLPE insulated armoured alluminium conductor cables with compression type steel gland, Bi-metallic lugs using crimping tool, Insulation tape, Identification tags etc., including end termination and Earthing of Gland with 8SWG GI Wire. , 4C X 50Sq.mmCu Armoured Cable , SUBHEAD-XVIII : SPECIAL EARTHING : , Providing and fixing of maintenance free earthing which consists of 65 MM Dia ,2.5mtr long electrode capsule,filled with earth enhancing compound,sealed at both ends and brazed lead for connection at one end suitable for direct installation at site at a depth of 2.5 mtr.Earth enhancingcompound upto a depth of 2.0 mtr around the electrode capsule and also wih brick chamber and cast Iron cover etc complete including excavation in all types of soil. , Supply and laying under ground/above ground offollowing size strips including all necessary interconnections between earth station and equipments including earth excavation, back filling, intermediate supports for strips as applicable and directed by engineer in charge. , 25 x 3 mm copper strip on DMC insulators , 25 x 3 mm copper stripbelow ground. , 50 x 5 mm copper stripbelow ground. , Supply and fixing of Static Discharge Handles made out of 40 mm dia Copper rod 600 mm Long fixed on wall with brass spacers and connected to 25 x 3 mm copper strip by brazing. , Supply, laying, jointing GI pipes of medium quality including specials of approved make fixed to wall/to the required lengths, threading jointing chasing the walls and floor, making holes, clamping of clamps and making good the same, necessary excavation, etc., complete as specifed and directed. , 50mm Dia , SUBHEAD-XIX : LIGHTNING PROTECTION : , Providing and fixing of maintenance free earthing which consists of 40mm Dia ,standrad length (as per Equipment Supplier ) electrode capsule,filled with earth enhancing compound,sealed at both ends and brazed lead for connection at one end suitable for direct installation at site at a depth of 2.5 mtr.Earth enhancingcompound upto a depth of 2.0 mtr around the electrode capsule and also wih brick chamber and cast Iron cover etc complete including excavation in all types of soil. , Supply and laying of following sizestripsincluding all necessary inter connectionsbetween earth station and equipment. supports for strips as applicable and directed by engineer in charge. , 32 X6 mm Aluminiumstrip conductor with DMC Insulator Supports , 50 X 5 mm GI strip conductor including excvation and back filling. , 25 X 5 mm Hot dip GI strip , Supply and installation of vertical air termination with 100mm dia copper hollow sphere with spikes, fixed on 1500mm length 50mm dia Class C GI pipe including all fixing accessories. , Providing and fixing of Test links for Lightning protection system. , SUBHEAD-XX: FIRE ALARM SYSTEM : , Supply, erection, testing and commissioning of Intelligent AddressableFire Alarm Control Panel(a minimum of 159 detectors/ 159 modules per loop )with Network Communication Module expandable to 2 loop, to monitor loop Devices located in allfloor with dual stage alarm facilities,built in buzzer,built in NAC Circuits & RS 485 port on CPU boardwith optional net work software connectivity, fire/fault indicators, audio-visual signals, battery, battery charger, central processing unit,80 character display unit,fibre optic converter and networking card etc complete in all respects . , 2 - Loop Panel ( One Loop for Integration ) , Supplying, installation, testing & commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches etc complete. , Supply, Installation, Testing and commissioning of Online UPS of 1 KVA capacity with built-in SMF Batteries (12V 7Ah X 3nos) for battery back up and regulated AC supply to the FAS. , COMIBINATION/MULTI SENSOR DETECTORS(Photoelectric + Heat Sensing) , Supply, fixing, testing and commissioning of Addressable anloguetype multi sensor detectors (Photo electric + Heat sensing) with dual chamber, solid state design,Rotatable DIP Switch Setting indicating lamp, mounting base etc. . , Supply, fixing, testing and commissioning of Response Indicators with all required accessories etc complete. , Supply, fixing, testing and commissioning of Addressable anloguetype Beam Detector with transmitter and receiverincluding short circuit isolator including connections with remote test features etc complete. Range 100 Mtr , MANUAL CALL POINTS: , Supply, erection, testing and commissioning of Addressable analogue typemanual call point for indoor installtion. , Supply, Installation, Testing and commissining of Addressable analogue type manual call point stations weather proofwith 1500 mm Length ISMC 100 standing Post. , FAULT ISOLATION MODULE: , Supply, fixing, testing and commissioning ofFault Isolation module. , Supply, installation, testing & commissioning of addressable fire control module complete as required. , Supply, installation, testing & commissioning of addressable fire Monitormodule complete as required. , CABLE: , Supply, laying , testing and commissioning of 1100 V grade FIRE RESITANCE LOW SMOKE PVC insulatedcopper conductor control cables as per specification. , Armoured Twisted pair2Cx 1.5 sq. mm. shielded FRLS insulated copper conductor cable to be laid on cable tray /to be clamped to wall including supply and fixing of clamps etc complete. , Armoured Twisted pair2Cx 1.5 sq. mm. shielded FRLS insulated copper conductor cable to be laid in cable trench including excavation and backfilling. , 3 core x 2.5 Sq.mm armoured sheilded twisted pair copper conductor cable on cable tray/on wall including clamping etc complete and including cable end termination with double compression weather proof cable glands and copper lugs. , Supply and Installtion of 12 Way Elmex terminal powder Coated junction Boxincluding all terminations andNecessary Glands. , Supply, Installation, Testing and commissioning of Weather proof siren to be operated on Single Phase 230 V, 50 Hz ,A.C.Supply with a range of 2/3 km distance including fixing clamps and accessories.complete. , Supply, laying of 50mm dia, class-B GI pipe including specials of approved make fixed to wall/to the required lengths, threading jointing chasing the walls and floor, making holes, clamping of clamps and making good the same, necessary excavation, etc., complete as specifed and directed. , Supply and laying of of 6 core 9/125 micro meters armored single mode optical fiber cable with suitable dia HDPE pipe (1300nm wave length) including splicing & terminations and laid in ground at 750 mm below ground including excavation andsand, brick protection and refilling of earth and cable route markers at every 50 meters intervals. 6C SM ARM-OFC - 6 C Armoured Single Mode Optical Fiber Cable networking card and fibre optic converter etc., complete. , Supply and laying of 25mm dia, 16 SWG black enamelled M.S. conduit on wall surface/ ceiling/ floor including all accessories such as junction boxes, conduit bends, etc., complete as requiredduly coated with two coats ofred colour enamel paintetc., complete. , SUBHEAD-XXI :FIRE FIGHTING SYSTEM : , Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required : , Single headed Gunmetal , Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze /gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : , 80 mm dia , 150 mm dia , Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required : , 80mm dia , 150mm dia , Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts,washers etc.as required : , 80mm dia , 150mm dia , Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : , Gun Metal , Supply, installtion, testing and commissioning off Hose Box to accommodate 2sets of CP hoses of 15 mtr length each and with 1 pair of Male and female coupling, and one branch pipe with nozzle. The cabinet shall be made of 16 SWG MS Sheet with double door glass front and painted with Scarlet Red colour of size 30x24. , Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : , Gun metal , Supply, Installation, Testing and Commissioning of Swinging type fire hose reel drum of Rubber hose 30mtrs length. , Supplying and fixing of fire brigadeconnectionofcast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : , 4 way - 150 mm dia M.S. Pipe , Providing, laying, testing & commissioning of C class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts,gaskets etc. in ground including welding, as supports, anticorrosive treatment with coaltar/asphalt/bitumen tape as per IS 10221, refilling the trench etc. of following sizes complete as required. , 150 mm dia. Pipe , 80 mm dia. Pipe , 50 mm dia. Pipe , Supply, errect, jointing, testing and commissioning of heavy class MS pipes (as per IS-1239). The pipes being fixed on to the wall or suspended from the ceiling/ truss with angle iron supports complete with bends, tees, flanges and with all other required accessories including painting of the pipeline with two coats of approved enamel paint over a coat of primer etc. complete. , 150 mm dia. , 100 mm dia. , 80 mm dia. , 65 mm dia. , 50 mm dia. , 40 mm dia. , 32 mm dia. , 25 mm dia. , Supply and installation , Testing andcommissioingofapproved make 15mm orifice quartzoid bulb pendent type sprinklers,68°C rating, recessed , Supply and installation, Testing andcommissioingofapproved make 15mm orifice quartzoid bulb side wallpendant type sprinklers,68°C rating. , Supply installation and fixing of flow switchesin the followingPipe line with1NO+1NC Contacts , a)150/100mm dia , Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. , In ordinary soil. , Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m : Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia , Hard rock (blasting prohibited) , Ordinary rock : , Construction valve chamber 1.8 Mtrs x 1.2 Mtrs x 1.2 Mtrs in first classbrick (table moulded) masonry in CM 1:6 on PCC bed to 100mm thick plastering with CM 1:4 internal and providing CI Cover with stiffness lifting arrangement frame work etc. complete with providing anticorrosive paint on both side for steel works.Cover should be in two halfs fixed to frame work by means of hinges. , Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : , 300 mm dia. R.C.C. pipe , Supply, laying, jointing, testing and commissioning heavy class M.S pipe (as per IS-1239) in Pump roomwithMS supports including two coats of red oxide and two coats of Red coloure enamel paint . Rate quoted shall include for necessary specials like long radius bends, tees, including cutting, welding/ flanged joints with necessary washers, nuts, bolts etc., complete. , 250 mm dia. Pipe , 200 mm dia. Pipe , 150 mm dia. Pipe , 100 mm dia. Pipe , 80 mm dia. Pipe , Supply, Installation,Testing and Commissioning of air cussion vessel ofcapacity 250 litreswith air releasevalve and ball valve. , Supply,Installation,Testing and Commissioning of PN 16Sluice valves with gateof the following sizes. , a) 250mm dia , b) 200mm dia , c) 100mm dia , Supply,Installation,Testing and Commissioning of PN 16Butterfly valves of the following sizes including flanges and hardware ,nuts and bolts etc complete. , a) 200mm dia , b) 80mm dia , Supply, Installation, Testing and Commissioning of CI Non Return valves of the following sizes. , a) 200mm dia , b)80mm dia , Supply, installation, testing and commissioning of approved make brass Y strainer with necessary flanges which should include nuts, bolts, washers, gaskets. , a) 200 mm dia. , c) 100 mm dia. , Supply,Installation,Testing and Commissioning ofelectrical control panel for diesel engine, main motor and for jockey pump comprising of following. , Incoming : 800A,50KA TPNMCCB - 1SET , 800A TPN aluminium busbars - 1set , Outgoings: , Main Fire Pump 250 Amp, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 100 hp pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. - 2 sets , (with built in single phase preventor) and ON/OFF/TRIP , indication lamps for motor-2set , Jockey Pump 125 Amp, 50kA TPN MCCB, Ics=100% Icu, with Suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. - 2 sets , Diesel Engine Control , Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0-20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System Controller Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification , Supply installation testing and commissioning of Instrumentation Board on type pressure gauges for pumps in delivery line and common delivery header , Supply fabrication and erection of MS angle supports for Pipe lines , Supply and fixing of G.M. ball type valves Conforming to IS , a) 25mm dia , b) 15mm dia , Supply, Installation, Testing and Commissioning of Pressure Switches. Make: Indfoss/Donfoss , Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS-325. M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered with anti vibration pads. 2280 lpm at 70 m Head with 70% of Pump efficiency. , Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. 2280 lpm at 70 m Head with 70% of Pump efficiency. , Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS : 325. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. 180 lpm at 70 m Head , Supply, Installation of following Fire extinguishers & accessories: , CO2 6.5 kg capacity trolley mounted , CO2 22.5 kg capacity trolley mounted , DCP 5 kg capacity (potassium bi-carbonate Uria reaction) , Water buckets with stand , Sand buckets with stand , Showels , Fire Beater , Fire gong/ hand siren , Ceiling Hook , Supplying, installation, testing & commissioning of 1000 MM sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. , Supplying, installation, testing & commissioning of 1500 MM sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. , Supplying Installation Testing & Commissioning of Ceiling Mountedexit sign/emergency lighting unit uses high-performance led lamps. , Supply installation testing and commissioning of900LPM,35mtrs head Booster pump with Suitable HP 2900 RPM Electrical motor and coupling as per TAC regulations with necessary accessory including base plate of MS channel and suitable reinforced CC foundation with nuts andbolts , Supply, installation, testing and commissioningof weather proof type MPCB box made out of 2mm thick CRCA sheet including painting with epoxypowder coating for Suitable HPBooster pump motor. The box shall be suitable for terminating AYFY cable ofsuitable angle frame work of 450mm height on a PCC pedestal including all materials Outgoings : DOL starter for 15HP with MPCB and contractor, over load relay, single phasing preventor and ON/OFF/TRIP , SUBHEAD-XXII: WATER COLLERS , Supply and fixing of 40 (cooling)/ 80 (storage) ltrswater cooler with water purifier (RO system) and voltage stabilizer etc. complete. , SUBHEAD-XXIII :LIFTS : , Supply, erection, testing and commissioning ofMachine room less gear less 1000Kgs Goods liftwith a speed of 0.75 meters per second,suitable for (Ground + 2floors) floors operation with 3 phase ACVVVF drive of suitable HP to operate on 415 volts 50 HZ with base including 1100X 1300X2300 mm car made of all stainless steel body, heavy duty cabin suitable for one number car entrance and landing entrance doors ( Center operated doors ) , SS hairline finish , with clear opening of 800x2100mmn height suitable for simplex selective and collective operation with or without attendant including call register and other parameters as per specification , SUBHEAD-XXIV : EOT CRANES , Design, Manufacture, supply , erection, testing and CommissioningofTandem operator (1 set consist of 2 nos of cranes)DoubleGirderNon FLPEOT Cranewithall speeds VVVF drivecontrol and micro speed arrangement for hoist, CT & LT and confirming to IS 807/IS 3177 /4137cand other relevant IS standards of the latest revisions as shown below complete with all taxes, duties and other charges such as transportation to site, loading and unloading at stores / building, where to be installed etc., movement of material to work spot including the cost of paint as required loaded testing at factory and at site. The crane shall be designed for earthquake and sesmic qualification.Span to be measured by the the Bidder at Site and it shall be its sole responsibility to provided Spansuitable . Design drawings and list of materail to be submitted to department duly approved checked by Govt., agency/ reputed technical institute as approved by department. VVVF drive controls with along travel andcross travel movement and with pendent control opeartion as per IS807 &IS3177(includingfestool cable, 60 lb rails, third party inspection, transportation, design proof check)Double Girder Box Type. 25% overload ,Duty class- III, head Room 2.5mtr,side clearence 300.indoor operation.AC Control Supply , Floor operated via pendant push button,All drives should be provided with alternative parallel path with DOL starter for Main Speed only , MOTORS- Conformingto IS 325-1978& 900-1965, , GEAR BOX- Electro Hydraulic Thrusters type,3Ph, 440V, A.C. Conforming with IS 3938 - 1983 , WIRE ROPE- 6X 36 Cont. Hempcore(IS 2365-1963) , Rope Drum- made from Seamless/ms rolled , Hook- Forged Material EN-3A , WHEEL ASSEMBLY- Made from forged steel- Double flange hardened to BHN 275 Conforming with IS 807-1976. , BEARING- All bearings are of anti Friction Ball/ Roller Conforming, with IS 6455-1972 , COUPLING- AlI Couplings will be Geared Coupling , SHAFT-All Shafts will be of EN - 9 , RESISTANCE BOXES- AlI resistance boxes will be stainless steel, Wire grid and 15 min. Rated heavy duty, (IS 1822 -1967 ) , LIMIT SWITCH- Rotary Limit Switch for Hoisting & Lever Type for L.T &C.T. Conforming with IS- 3936 - 1983 , PANEL BOXES - All panel boxes will be of steel febricated , CONTROL TRANSFORMER- 750 VA, 44OV / LLOV. , POWER CONTROL CABLE -Sheet Metal housing, DustlVermin Proof having BCH/Siemens Contactors & Overload ReIays BCH time delay Relay , PAINT- Two coats of Red Primer & Two coats of Golden Yellow. , Fullplatform on driving side & two small platform on non driving side.(Monkey ladder &side railing shall be provided by civil) , PART- I : SUPPLY , Supply of Non-FlameproofTandem Operated ( 1 set consist of2 Nos of 5 Ton capacity cranes) 5 Ton capacityDoubleGirder Crab type EOT Crane with VVVF drive complete with long travel and cross travel movements as per technical specifications and as per IS: 807 / IS: 31774137 and other relevant IS standards of the latest revision.All drives should be provided with alternative parallel path with DOL starter for Main Speed only. Span:14.5 mts. ± 0.5 mtrs.to bechecked as per site condition ± Lift: 8.5 mts. Bay length: 73± 0.5 mtr (to bechecked as per site condition ± , Crane operating speeds , Main speed Micro speed , Main hoist:2.5m/min 0.25m/min , Cross travel :10m/min1.0m/min , Long travel: 15m/min 1.5m/min , Micro speedfor all motions : 10% of main speed through VVVF drives. , Provision of inching is to be incorporated in the drives. , Supply of shrouded bus bar system with double shoe copper current collections system complete with support tracks, cable loops, junction boxes and cable from main supply point to crane festoons with all necessary fixtures etc completeas per site condition (For 5 ton capacity crane as per above BOQ EOT 1.1) , Supply of material for Gantry Rails section 60 lb of prime material in length of 10 mts and above complete with mounting arrangement at the building over the crane girder including painting of rails with approximate colour code as approved by the dept as per site condition(For 5 ton capacity crane as per above BOQ EOT 1.1) , Supply of Non-FlameproofTandem Operated ( 1 set consist of2 Nos of 2 Ton capacity cranes) 2 Ton capacityDoubleGirder Crab type EOT Crane with VVVF drive complete with long travel and cross travel movements as per technical specifications and as per IS: 807 / IS: 31774137 and other relevant IS standards of the latest revision.All drives should be provided with alternative parallel path with DOL starter for Main Speed only. Span:17.5 mts. ± 0.5 mtrs.to bechecked as per site condition ± Lift: 5.5 mts. Bay length: 17.5± 0.5 mtr (to bechecked as per site condition ± , Crane operating speeds , Main speed Micro speed , Main hoist:2.5m/min 0.25m/min , Cross travel :10m/min1.0m/min , Long travel: 15m/min 1.5m/min , Micro speedfor all motions : 10% of main speed through VVVF drives. , Provision of inching is to be incorporated in the drives. , Supply of shrouded bus bar system with double shoe copper current collections system complete with support tracks, cable loops, junction boxes and cable from main supply point to crane festoons with all necessary fixtures etc completeas per site condition (For 2 ton capacity crane as per above BOQ EOT 2.1) , Supply of material for Gantry Rails section 50 mm sqr barof prime material in length of 10 mts and above complete with mounting arrangement at the building over the crane girder including painting of rails with approximate colour code as approved by the dept as per site condition(For 2 ton capacity crane as per above BOQ EOT 2.1) , Part-II: - ERECTION, TESTING AND COMMISSIONING , Erection, testing and commissioning ofNon FLP EOTTadem Opereated followingDouble Girder EOT Cranesincluding loaded testing and others mentioned in item S.No.EOT-1.1 to EOT-2.3 of Part-I as per the relevant IS standards and as mentioned in the technical specifications. , Erection, testing and commissioning ofNonFlameproof Tadem Opereated Double Girder EOT Cranes of 5 Ton capacity( 1 set consist of2 Nos of 5 Ton capacity cranes) mentioned in Items .No.EOT-1.1of Part-I with VVVF drive complete with long travel and cross travel movements as per technical specifications and as per IS: 807 / IS: 3177 and other relevant IS standards of the latest revision.including loaded testingAll drives should be provided with alternative parallel path with DOL starter for Main Speed only. Span:14.5 mts. ± 0.5 mtrs. Lift: 8.5 mts. Bay length: 73± 0.5 mtrto bechecked as per site condition ± , Erection testing and commissioning of shrouded type current collection system complete as per the item Sl No.EOT-1.2 of Part I over the crane bay including tapping of supply for electrical panel testing & handing over the crane as per the approved QA plan etc complete as per site condition. , Erection, testing & commissioning of Gantry rail section 60 Lb mentioned in item Sl No.EOT-1.3 of Part -I with mounting arrangementand fixing hardware etc., complete over the bay length to match the span of the crane within the permissible accuracy levels for span in height variation as per the QA Plan etc complete as per site condition. , Erection, testing and commissioning ofNonFlameproof Tadem Opereated Double Girder EOT Crane of( 1 set consist of2 Nos of 2 Ton capacity cranes)mentioned in Items .No.EOT-2.1of Part-I with VVVF drive complete with long travel and cross travel movements as per technical specifications and as per IS: 807 / IS: 3177 and other relevant IS standards of the latest revision.including loaded testingAll drives should be provided with alternative parallel path with DOL starter for Main Speed only. Span:17.5 mts. ± 0.5 mtrs. Lift: 5.5 mts. Bay length:17.5± 0.5 mtrto bechecked as per site condition ± , Erection testing and commissioning of shrouded type current collection system complete as per the item Sl No.EOT-2.2 of Part I over the crane bay including tapping of supply for electrical panel testing & handing over the crane as per the approved QA plan etc complete as per site condition. , Erection, testing & commissioning of Gantry rail section 50 mm sqr barmentioned in item Sl No.EOT-2.3 of Part -I with mounting arrangementand fixing hardware etc., complete over the bay length to match the span of the crane within the permissible accuracy levels for span in height variation as per the QA Plan etc complete as per site condition. , Supply of Test loads of 5 Ton along with Slings and D-shakles (Suitable for 5 Ton, loads of 5 ton -1 no, 1 ton-1 nos, 0.25 ton -1 nos , Supply of Test loads of 2 Ton along with Slings and D-shakles (Suitable for 2 Ton, loads of 2 ton -1 no, 0.5ton -1 nos , SUBHEAD-XXV : BOOM BARRIER: , Supply,Installation,Testing and commissioning of 6 mtr length Boom Barrier electromechanical hydraucally operatedopening and closing times can be adjusted between 3 to 6 seconds and speeds can be adjusted seperately through hydraulic adjusters in a closed circuit system optional emergency close option 2 seconds shall be available with 100% duty cycle with power supply unit,photo sensors,flashing lights on the boom ,push button for entry,exit & Remote control.This shall be along with safety features like Induction and safety loop etc with remote operating facility with remote control unit,along with 4 nos of photo cells with each boom barrier.The system shall be complete in all respects along with all fixing accessories and civil works , SUBHEAD-XXVI :ROADS/HARDSTANDING & DRAINS : , Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres. , Banking excavated earth in layers not exceeding 20 cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller, or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up, in embankments for roads, flood banks, marginal banks, and guide banks etc., lead upto 50 m and lift upto 1.5 m in all kinds of soils. , Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge. , Providing and laying Bituminous concrete using crushed stone aggregates of specified grading, premixed with bituminous binder and filler, transporting the hot mix to work site by tippers, laying with paver finisher equiped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction and density as per specification, complete and as per directions of Engineer-in-Charge. , 40/50 mm compacted thickness with bitumen of grade VG-30 @ 5.5% (percentage by weight of total mix) and lime filler @ 3% (percentage by weight of Aggregate) prepared in Batch Type Hot Mix Plant of 100-120 TPH capacity. , Providing and applying tack coat using bitumen emulsion conforming to IS:8887, using emulsion pressure distributer including preparing the surface & cleaning with mechanical broom.With rapid setting bitumen emulsion. On W.B.M / W.M.M. @ 0.4kg/Sqm. , Providing and laying seal coat of premixed fine aggregate ( passing 2.36 mm and retained on 180 micron sieve) with bitumen using 128 kg of bitumen of grade VG - 10 bitumen per cum of fine aggregate and 0.60 cum of fine aggregate per 100 sqm of road surface, including rolling and finishing with road roller all complete. , Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). , SUBHEAD-XXVII :EXTERNAL WATER SUPPLY SERVICES: , Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. , 25 mm dia nominal bore , 40 mm dia nominal bore , 50 mm dia nominal bore , 100 mm dia nominal bore , Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : , 50 NB , Making connection of G.I distribution branch with G.I mainof folloeing size by providing and fixing tee, inclding cutting and threading the pipe etc. complete: , 25 to 40 mm nominal bore , 50 to 80 mm nominal bore , Providing and fixing gun metal non- return valve of approved quality (screwed end) : , 25mm nominal bore , 40 mm nominal bore , 50 mm nominal bore , Supply,erection, testing and commissiong of C.I Air release valves flanged end type with bolts,nuts and rubber insertions etc., complete andof following sizes: , 25mm nominal bore , 50 mm nominal bore , Supply and Fixing of cast iron pipe line Route Marker for water supply Network system , Borewells , Geological Survey by specialist Agencies and submitting the report for number of poit surved and yield available , Drilling and developing of 61/2 inch dia Bore Wells by DTH method in any type of soil, Conducting yield test as per V Notch method and submission of yield report, including filling of filter media clamps, MS Cover etc., complete. , a) 0-60 mtrs , b) 61-100 mtrs , c) 101-200 mtrs , Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm Dia. , Providing HDPE pipe PE-80 grade (12.5 kg/ sq.cm) of 63 mm OD for bore wells. , Supply, erection, testing and commissioning of 3 Cu.m/hr at 70 m head submersible pump set 3Phase-415V, 50 Hz, 2 HP/ 12 stages, 2900 rpm as approved by Engineer in charge at site.(As per depth of base) , Supply, erection, testing and commissioning of Gun metal Check valve (Non return valve PN-10) conforming to IS 778 with screwed ends type with bolts, nuts and rubber insertions etc., complete and of following sizes: , a)50 NB , Supply, erection, testing and commissioning of Brass / GM / Bronze Air Release valves with threaded ends of following sizes: , a) 25 NB , Supply, erection, testing and commissioning of pressure gauges with range of 0-10 bar along with isolation cock and pipe for bore wells. , Supply, installation, testing and commissioning of weather proof type box (IP-55) made out of 2 mm thick CRCA sheet including painting with epoxy powder coating. The box shall be consisting of star-delta starter suitable for 3 Cu.m/hr and 200 meters head pumpmotor with MPCB, contactor, overload relay, ON/ OFF push button. ON/ OFF/ TRIP indications. Ammeter with resin cost Cts and selector switch, Voltmeter with selector switch. The box shall be suitable for terminating suitable cable. The box shall be mounted on suitable angle frame work of 450 mm height on a PCC pedestal including all materials, complete. , Providing maintenance free Earth station with consisting of 40 mm dia pipe standard length (as per equipment supplier) electrode capsule, filled with earth enhancing compound, sealed at both ends and brazed lead for connection at one end, suitable for direct installation at site, at a depth of 2.5 mtrs. Bentonite compound (as per equipment supplier) upto a depth of 2.0 meters around the electrode capsule. Brick chamber & CI Cover complete. , Supply and laying of following size strips including excavation and refilling of each when laid in ground and with all fixing accessories when laid inside the building including all necessary interconnections with earth station and equipments. , a) 25 x 5 mm hot dip galvanized iron strip , b) 8 SWG GI Wire , Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m in All kinds of soils , Supply, Laying, testing and commissioning of Medium grade G.I. Pipes conforming to IS 1239 Part - I including all necessary fittings etc., complete for sizes , a) 65 NB (Borewell to sump) , b) 50NB (Borewell) , c) 40NB (Borewell to sump) , d) 32NB , e) 25NB , Supply, Erection, testing and commissioning of Cast Iron Butterfly valves (Wafer type) (PN-10) above nd upto 50mm dia with necessary flanges, bolts, nuts etc., and gun metal gate valves from 40mm dia and below , a) 65NB(GM Gate Valve) , b) 50NB(GM Gate Valve) , c) 40NB(GM Gate Valve) , d) 32NB (GM Gate Valve) , e) 25NB (GM Gate Valve) , Constructing of Valve Chamber of size 750 x 750 x 1000mm deep comprising of 230mm thick brick walls in cement mortar 1:5 over a bed of 150mm thick PCC 1:4:8 alround beyond the masonry faces plastered with CM 1:3 mixed with approved water proofing compound as per manufacturers specifications, 13mm thick on internal, external, top surfaces, finished smooth with a floating coat of neat cement, providing and fixing painted light duty double seal CI frame and cover of size 600 x 450mm weighting not less than 52 kgs conforming to IS 1726 with locking arrangements, fixing the frame in RCC 1:2:4 including fabrication, form work, curing etc., complete all as specified and directed. , Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete (a) 50 to 80 mm nominal bore: , Providing and fixing gun metal non- return valve of approved quality (screwed end) :Vertical (a) 50 mm nominal bore . , Supply, laying and commissioning of following size 1.1KV grade PVC insulated flexible Copper conductor in the bore withall installation materials. The cable shall conform to IS 694 , a) 3C x4sqmm (copper ), pvc Flat Water proof cable. , Conducting water yield test without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by V notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. , Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. , 200mm clamp , SUBHEAD-XXVIII : EXTERNALELECRIFICATION , 11KV HT SWITCHGEAR INDOOR , Supply,Installation,Testing and commissioning ofthe following indoor floor mounted 11kv Rated VCB Panel in Metal Enclosure fabricated out of 14 swg sheet steelto be operated on 11KV,Three phase,50HZA.C Power supply .The panel is to be compartmentalised with individual compartments for Bus bars, Cable and CTs and Instrument and relay control Panel. The VCBshall behorizontal draw out single breakas per IS 13118.The short circuit fault level of the system shall be 350MVA- Indoor , 11 KV- H.TSWITCH GEAR PANEL - INDOOR , 11KV VCB panel withone noof1250A vcb -Indoor as Incomer and 3 Nos 800A VCB as out goings. , 11 KV H.T Switch Gear Panel (INDOOR TYPE) With 1 No. OF 1250 Vaccum Circuir breakerasIncomer. , CONSTRUCTION - The Switch Gear Panel shallbe compartmentalised Designed with cubicles fabricatedout of High Quality Sheet Steel. The panels shall be designed having the Following Segregations separately. , a) Busbar compartment , b) Cable and CT compartment , c)) Instrument and Relay Compartment , The clearances between phase to phase and phase to earth shall be provided in accordance with the relevant standards. The bus bars shall be supported by bus support insulators placed at regular intervals. , The panels shall be powder coated with epoxy base paint to give an aesthetically pleasing appearance. The paint shade shall be as per the requirement. , SAFETYFEATURES: , a) Mechanical Interlock and earth switch for out goings , b) Door interlock in service position. , INCOMING VCB PANEL , 11 , KV, 1250A, 26.2 KA,Horizontal Draw out type Vaccum Circuit breaker withmotor/manual spring charge mechanism and also with mechanical indications for breaker on /off/trip indications and also with Local Remote selector switch and with breaker TNC Switch. , CURRENT TRANSFORMER: (3 No’s) Cast Resin , Ratio 200-100- 5/5 A, Core 1: 15 VA, CI – 0.2 for Metering and 5P10 for protection. , METERING: ( 1set) , 96 Sq.mm Digital Ammeter with selector switch Digital type 0-200A. , POTENTIAL TRANSFORMER: (3 No’s) Cast Resin , Ratio 11000 V/ rt 3 / 110 v / rt 3 , 100 VA, CI – 0.2 for Metering and 3 P for Protection and also with 2 numbers of Under Volage relays. , OUTGOING VCB PANEL , 11 , KV, 800A, 26.2 KA,Horizontal Draw out type Vaccum Circuit breaker withmotor/manual spring charge mechanism and also with mechanical indications for breaker on /off/trip indications and also with Local Remote selector switch and with breaker TNC Switch.-Outgoing-4Nos , CURRENT TRANSFORMER: (3 No’s) Cast Resin , Ratio 75 /5 A, Core 1: 15 VA, CI – 0.2 for Metering and 5P10 for protection. , METERING: ( 1set) , 96 Sq.mm Digital Ammeter with selector switch Digital type 0-100A. , Digital Multi function Meter for KW,KWH,KVA, KVAR , COS PHI Parameters reading. , INDICATION LAMPS: , 1) TCH, Battery failure , Spring charge, discharge, ON, OFF and Trip Indication Lamps, Phase indication Lampsfor RYB.-(1 set) , CONTROL SWITCHES/PUSH BUTTON , Bus Bar with 1250 Amps Copper- (1 set) , COMMON FOR SWITCHGEAR: , Heater ON and OFF Switch with Space heater, single Phase switch socket and cubicle lamp for panel illumination, MCBs for AC/DC Control - (1 set) , MS sheet enclosure suitable for Indoor installation withoutgoing cable entry.- (1 set) , RelaysIncomer ; Undervoltage relays 2 nos,IDMT relay ,TCH and Master trip relay and also with 12 window annunciator , Power Pack - 1 No with necessary Interconnections. , Supply andcommissioning of 11KV earthed HT cable of size3 c x300 sqmm XLPE insulated armoured alluminium conductor cable as per IS 7098- Part 2 - 1983 , Supply andcommissioning of 11KV earthed HT cable of size3 c x185 sqmm XLPE insulated armoured alluminium conductor cable as per IS 7098- Part 2 - 1983 , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. , Above 120 sq. mm and upto 400 sq. mm , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. , Above 120 sq. mm and upto 400 sq. mm , Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size on cable tray as required. , Above 120 sq. mm and upto 400 sq. mm , Supply, Installation, Testing and commissioning of 11 KVearthed heat shrinkable end termination kit of 11 KV earthed XLPE insulated armoured alluminium conductor HT Cable of size 3 c x 300sqmm ( Indoor Termination Kit). , Supply, Installation, Testing and commissioning of 11 KVearthed heat shrinkable end termination kit of 11 KV earthed XLPE insulated armoured alluminium conductor HT Cable of size 3 c x 185sqmm ( Indoor Termination Kit). , Supply and Installation ,Commissioning of HT Straight through Joint Kit for 3 C x 300 Sqmm EarthedXLPE insulatedarmoured alluminium conductor cable. , Supply, Installation, Testing and commissioning of 1000KVA, 11kv / 433 v, 3 PHASE, 50 Hz, Dyn 11 ,outdoorANAN Resin cast dry typeTransformerwithon load tap changer, RTCC panel, AVR andHT Side marshalling box for termination of 11 kv grade , 3 c x 300 sqmm XLPEinsulated alluminium conductor screeened cable and LT side provision for connecting sandwich type of Alluminium bus trunking system of 1600 A capacityas per IS 11117 etc , LT SANDWICH TYPE BUS DUCT , Supply, Installation, Testing and commissioning of 415 V, 50 Hz, A.C, 1600 A, Three phase and neutral Sandwhich type Alluminium bus bars Bus trunking system with necessary fixing Clamps and Jointing accessories including all required horizontal and vertical bends, tees for outdoorApplicationIp -65( Transformer feeder Incomer ) .As p-er IS ; 8623 Part 1 & 2. , M.V.PANELS , Supply,Installation Testing Commissioning of following TTA PANEL.Supply, erection, testing and commissioning of 415V, 3 phase 4 wire 50 c/s Main LT Panel at Substation fully compartmentalized cubical type, as per the standards IEC61439-1&2 as tested assembly (TTA) ,tested for impulse voltage 8 KV,IP 42 fabricated CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having required capacity extensible type FP bus bars of high conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 35KA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, Form of separation shall be form 4b with metallic separation only entire panel shall have a common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of bus bars, interconnection, interlocking between feeders etc.,with indication lamps, push buttons necessary accessories, complete with following incoming and outgoing switchgears with protection and metering etc. as per specification and schematic diagram including provision to be made for interfacing with BMS etc. complete as required, with incoming & outgoing cable entry from bottom/top and bus-duct entry from top, wiring with 2.5sq. mm. FRLS insulated copper conductor , cable alleys, PLC cable gland i/c providing following switch gears All ACBs should have Ics=Icu=Icw for 1 sec All MCCBs shall be rating for 25kA (Ics=Icu). All MCCBs above 63A should be provided with Copper Spreader Terminals Marshalling Bay To Be Provided for BMS Operation Approval shall be taken for each panel before fabrication. PLC based control with 100% hot redundant PLC arrangement with touch-screen LCD / LED display board (min. 8 Diag size)along with all accessories for complete automatic, manual andHMI controls & indication. Energy Management Software wth necessary cabling shall be in scope, nos. of breaker / Meters to be connect with energy management software shall be inform by Engineer In Charge. , MAIN MVPANEL - 1- Indoor , Incomer 1,3,4 : 3 Nos of 1600 A, 4P. EDO ACB, 50KA,shallbe supplied with S/C,E/F,O/C AND INSTANTANEOUS TRIP RELAY UNIS WITH TIME DELAY SETTINGS. , 2A, control MCB - 9 Nos. , RYB indicating lamps - 3 sets , Voltmeter (0-500V) with selector switch - 3 sets , Ammeter (0-1600A) with selector switch - 3 sets , 1600/5A, CL-1, 15VA CTs with resin cast- 3 nos. , A Single CT with ratio of1600 / 5 A , 15 VA, 5 P 10 ,CT for feeding APFC relay of APFC panel. ( For 3 Nos of Incomers ) , Bus Coupler : 3 Nos of 1600 A, 4P. EDO ACB, 50KA,shallbe supplied with S/C,E/F,O/C AND INSTANTANEOUS TRIP RELAY UNIS WITH TIME DELAY SETTINGS. , Incomer 2 : 1 No of 1250 A, 4P. EDO ACB, 50KA,shallbe supplied with S/C,E/F,O/C AND INSTANTANEOUS TRIP RELAY UNIS WITH TIME DELAY SETTINGS. , 2A, control MCB - 3 Nos. , RYB indicating lamps - 1 sets , Voltmeter (0-500V) with selector switch - 1 sets , Ammeter (0-1250A) with selector switch - 1 sets , 1250/5A, CL-1, 15VA CTs with resin cast- 1 nos. , A Single CT with ratio of1250 / 5 A , 15 VA, 5 P 10 ,CT for feeding APFC relay of APFC panel. , Outgoing , 1250A, 3P, 50KA, EDO ACB - = 2 Nos , 800A, 3P, 50KA, EDO ACB - = 3 Nos , 630A, 3P, 50KA, EDO ACB - = 3 Nos , 250A, 3P, 35KA, MCCB, -=1 No , 200A, 3P, 35KA, MCCB, -=1 No , 160A, 3P, 25KA, MCCB, -=2 Nos , 63A, 3P, 16KA, MCCB, -=3 Nos , Surge Protection Device - 1 No , 63 A, 3P, 16KA, MCCB, -= 1 No and also with 20 A TPNMCB as outgoings 3 Nos with timer circuit for controlling of street lights and the timer should be with required24 hors clock settings. , Bus Bars : 1600A, 3Ph, 4 wireTPN , 50Hz, aluminium bus bars , Metering Instruments ; Load Manager in the Incomer and ACB/ MCCB on , off , Trip Indication Lamps and with Breaker Status indication Lamps and also with Phase indication Lamps. , Earth Bus; To be provided at the bottom of the Panel of Gi Strip , MAIN BUILDING PANEL- INDOOR , Incomer: 1 No of 1250 A, 4P. EDO ACB, 50KA,shallbe supplied with S/C,E/F,O/C AND INSTANTANEOUS TRIP RELAY UNIS WITH TIME DELAY SETTINGS. , 2A, control MCB - 3 Nos. , RYB indicating lamps - 1 sets , Voltmeter (0-500V) with selector switch - 1 sets , Ammeter (0-1250A) with selector switch - 1 sets , 1250/5A, CL-1, 15VA CTs with resin cast- 1 nos. , A Single CT with ratio of1250 / 5 A , 15 VA, 5 P 10 ,CT for feeding APFC relay of APFC panel. , Outgoing , 630A, 3P, 50KA, EDO ACB - = 2 No , 630A, 3P, 50KA, MCCB - = 2 Nos , 250A, 3P, 35KA, MCCB, -=3 Nos , 200A, 3P, 35KA, MCCB, -=2 Nos , 63A, 3P, 16KA, MCCB, -=3 No , Surge Protection Device - 1 No , Bus Bars : 1250A, 3Ph, 4 wireTPN , 50Hz, aluminium bus bars , Metering Instruments ; Load Manager in the Incomer and ACB/ MCCB on , off , Trip Indication Lamps and with Breaker Status indication Lamps and also with Phase indication Lamps. , Earth Bus; To be provided at the bottom of the Panel of Gi Strip , APFC PANEL INDOOR TTA PANEL - 300KVAR , Supply,Installation,Testing andCommissioning of APFC PANEL with Automatic power factor control relay and with 2 nos of 50 kvar capacitor banks and 25 kvar capacitor banks 8 nos with the following incoming and out goings.. The Panel is to be installed in Indoor. The panel is to be supplied with necessary power and control wiring required for the automatic operation of Power factor control. , INCOMER , 630 A, 4 P , 50KA MCCB with O/c, S/c,E/f Protection Microprocessore Relay Unit , 2A, control fuse - 3 Nos. , RYB indicating lamps - 1 set , Voltmeter (0-500V) with selector switch - 1 set , Ammeter (0-630A) with selector switch - 1 set , 630/5A, CL-1, 15VA CTs with resin cast- 3 nos. , Outgoing , 125 A, 3P, SDF , - 2No , 63 A, 3P, SDF , - 8 No , Bus Bars : 630A, 3Ph, TPN, 50Hz, aluminium bus bars , Metering Instruments ; Multi Function Meter in the Incomer and SDFon , off , TRIP Indication Lamps and with Breaker Status indication Lamps and also with Phase indication Lamps , Earth Bus; To be provided at the bottom of the Panel of copper , The panel is to be supplied with Required capacity Capacitor Banks as per BOQ quantity and also with required capacity over load relays,contactors ,Switch disconnecting fuses and also with APFC relay control wiring for manual and Auto operation. , EARTHING , Providing and fixing of maintenance free earthing which consists of 40 mm Dia, 3 mtr length (as per Equipment Supplier) electrode capsule,filled with earth enhancing compound,sealed at both ends and brazed lead for connection at one end suitable for direct installation at site at a depth of 2.5 mtr.Bentonite compound upto a depth of 2.0 mtr around the electrode capsule and also wih brick chamber and cast Iron cover etc complete including excavation in all types of soil. , Providing and fixing of maintenance free earthing which consists of 65 mm Dia, 3 mtr length (as per Equipment Supplier) electrode capsule,filled with earth enhancing compound,sealed at both ends and brazed lead for connection at one end suitable for direct installation at site at a depth of 2.5 mtr.Bentonite compound upto a depth of 2.0 mtr around the electrode capsule and also wih brick chamber and cast Iron cover etc complete including excavation in all types of soil. , Supply and fixing of following earth strips/ conductors.The scope incudes supply and fixing of copper lugs wherever found necessary, brass bolts, nuts and washers for fixing arrangement etc., (from earth station to main panel). , 50x5 MM G.I.Flat , 25 x3 MM GI Flat , 50 x 6MM Copper Flat , 6SWG G.I.Wire , Cable Trays , Supply and fixing of following size GIPerforated type cable tray made out of 2mm thick sheet including MS supports for fixing the tray, anchor fasteners etc complete as required.Including with GI covers. , 600mm wide , 300mm wide , SAFETY ITEMS , Supply, Installation, Testing and commissioning of the Follwing Safety itemsas per standrads and specification. , Fire Extinguishers- 5 KG CAPACITY CO 2 Confirming to IS 2878 fitted with discharge bend pipe and horn , Rubber Mats 11 KV , 2 Mtr x 1 Mtr , Rubber Mats 415 V , 2 Mtr x 1 Mtr , Shock treatment Chart with frame and glass , First Aid Box , Sand Bucket with stand with 3 Nos of buckets and also with canaopy. , 415 V Danger Boards , 11 kv Danger Boards , Single Line Diagram with frame and glass. , Supply, testingand commissioning of following size 1.1KV grade XLPE insulated armoured aluminium conductor cable. The cable shall conform to IS 7098/ Part-II. , 3.5C X 400Sq.mm , 3.5C X 300Sq.mm , 3.5C X 240Sq.mm , 3.5C X 185Sq.mm , 3.5C X 150Sq.mm , 3.5C X 95Sq.mm , 3.5C X 70Sq.mm , 3.5C X 50Sq.mm , 3.5C X 25Sq.mm , 4C X 16Sq.mm , Copper armoured control cables , i) 4C X 2.5Sq.mm , ii) 7C X 2.5Sq.mm , iii) 19C X 2.5 Sq.mm , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. , Upto 35 sq. mm , Above 35 sq. mm and upto 95 sq. mm , Above 95 sq. mm and upto 185 sq. mm , Above 185 sq. mm and upto 400 sq. mm , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. , Upto 35 sq. mm , Above 35 sq. mm and upto 95 sq. mm , Above 95 sq. mm and upto 185 sq. mm , Above 185 sq. mm and upto 400 sq. mm , Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. , Upto 35 sq. mm , Above 35 sq. mm and upto 95 sq. mm , Above 95 sq. mm and upto 185 sq. mm , Above 185 sq. mm and upto 400 sq. mm , Providing Indoor ordinary end terminations for thefoollwing 1.1 KV grade XLPE insulated armoured alluminium conductor cables with compression type steel gland, Bi-metallic lugs using crimping tool, Insulation tape, Identification tags etc., including end termination and Earthing of Gland with 8SWG GI Wire. , 3.5C X 400Sq.mm , 3.5C X 300Sq.mm , 3.5C X 240Sq.mm , 3.5C X 185Sq.mm , 3.5C X 150Sq.mm , 3.5C X 95Sq.mm , 3.5C X 70Sq.mm , 3.5C X 50Sq.mm , 3.5C X 25Sq.mm , 4C X 16Sq.mm , End terminations of Copper armoured control cables including supply and fixing of crimping type copper lugs. , i) 4C X 2.5Sq.mm , ii) 7C X 2.5Sq.mm , iii) 19C X 2.5 Sq.mm , SUBHEAD-XXIX : AREA LIGHTING : , Supply and erection of steel stepped and swaged tubular poles of 9 mtr long(410 SP25) (1.5 mtr below ground) with base plate earthing studs 1.5 mtr out reach single /Double arm , FRP terminal Box 2 Nos of 40 mm Dia Class B G.I Pipe ,0.5 mtr Longfor incoming and outgoing cables including excavation in all types of soil ,PCC 1:2:4 ,PCC Pedestal with painting with black bitumen paint inside the coping for embedded portion and two coats of Zinc chromite primer and two coats of Alluminium paint externally for length above the ground.The pole shall be with FRP junction box consisting of 10A MCB.The wiring from Junction box to Light fixture shall be carried out with 3 Core 2.5 Sqmm Copper conductor flexible cable. , The Street Light Pole shall be fixed with 70W LED street Light fixture including supply of controlgear / driver and lamp(Make : Cat No.LR02-102-XXX-57-G2,WIPRO MAKE / CAT NO - Greenline V2 (BRP410) Philips/equivalent make.) , Supply and erection of 65 mm Dia, Class B GI Pipe of 3 mtr. long with base plate, earthing studs, 3 phase and neutral loop-in and loop-out box as per specifications, 2nos 50mm dia,1.5mtr. long GI bent pipes for incoming and outgoing cables, including excavation , 1 :2 : 4PCC Pedestal etccomplete. The pole shall be with Junction box consisting of MCB.The Junction box shall be of weather proof. The wiring from Junction box to Light fixture shall be carried out with 3core 2.5sq.mm flexible copper conductor cable. The Pole shall be fixed withweather proof 72W LED ( Philips Cat No :BRP046 LED 30 CW MR S1 PSU GR/equivalent) Light fixtureincluding supply of driver and fixing clamps etc complete. , Supply, testingand commissioning of following size 1.1KV grade XLPE insulated armoured aluminium conductor underground cable. The cable shall conform to IS 7098/ Part-II. , 4Core10sq.mm , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required , Upto 35 Sqmm , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. , Upto 35 Sqmm , ProvidingEnd terminations for the following size of 1.1 KV grade XLPE insulated armoured alluminium conductorcablewith compression type steel gland, alluminumlugs using crimping tool, Insulation tape, Identification tags etc.,complete , 4Core 10 sq.mm , Providing Spiral coil earthing with 8 SWG GI wire including spreading of salt and charcoal as per IS 3043/87 with latest amendments. , Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, weather proof MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powderpainted including earthing etc. as required. (But without MCB/RCCB/Isolator) , 4 way (8 + 12), Double door , Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuitbreaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. , 40A , Supplying and fixingof 6A to 32A rating 240/415V,10kA , C Curveminiature circuit breaker suitable for inductive load of following polesin the existing MCB DB complete with connections ,testing and commissioning etc complete. , Single Pole , Supply and Commissioning of thefollowing type Fluorescent/ Compact fluorescentlight fixtures on wall/ Ceiling including all fixing accesssories such as leads, etc complete as required. The Fluorescent/CFL fixtures shall be complete with Low loss copper ballast PF improvement capacitor, Bipin Rotor type lamp holder,starter, starter base, all prewired upto the terminal block. All fixtures shall besupplied with lamps. The Catalogue Numbers refers to Philips Make. , 40 W Bulk Head Light Fixture Outdoor , (PhilipsCat No WT1 40W LED 7S NW PSU S1 PC /Equivalent as per approved makes)) , 150WLED Flood Light Fixture outdoor with alluminium die cast housing and also includind driver with fixing clamps etc complete , (PhilipsCat No BVP283 LED240 CW FG SY5NB 200W V1 /Equivalent as per approved makes)) , Installtionof Fluorescent/ Compact fluorescentlight fixtures on wall/ Ceiling including all fixing accesssories such as leads, etc complete as required. , SUBHEAD-XXX :SEWAGE DISPOSAL : , Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m in All kinds of soils. , Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. , PVC SWR PIPES , Providing, laying and jointing PVC/ SWR Pipes conform to IS:13592-1992 of Type-B on sand cushion at bottom and around the pipw and testing of joints etc. complete : , 100 mm dia PVC/SWR Single Socket , 150 mm dia PVC/SWR Single Socket , Providing and fixing square-mouth PVC gully trap conform to IS:13592-1992 complete with brick masonry chamber around as per standard design : , 100x100 mm PVC Gully trap with Sewer bricks conforming to IS : 13592-1992. , Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : , Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), With Sewer bricks conforming to IS : 4885. , Extra for depth for manholes : , Size 90x80 cm, With Sewer bricks conforming to IS : 4885 , Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design, With 20x20 mm square bar. , Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design, With common burnt clay F.P.S. (non modular) bricks of class designation 3.5. , Supply and positioning of ready made polyethylene septic tank of size 2.3M long 1.3M dia 16mm shell thickness with 2/3 chambers and 2Nos manholes of size 550mm dia and 100mm/160mm dia inlet outlet pipe and airvent pipe 50mm dia of make United Septic tank Design Reg.No 173352 Type-4 , SUBHEAD-XXXI : ARBORICULTURE : , TREE PLANTATION , Digging pits in all type of soils and refilling the same with the good earth (excavated / imported) & manure (organic manure/cow dung/sludge) in the ratio of 3:1 (03 part of stacked volume of manure). Cost of manure / sludge and good earth if needed to be paid separately, after reduction of 20% of stacked volume of good earth &8% stacked volume of manure. Each pit to be mixed with antitermite chemical / granules, Thimet 10G @100-200 am/pit , (I) AVENUE / FLOWERING TREES / Palms , a) 1mts x 1mts x 1mts (L X W x D ) , b) Each pit to be added with 100gms of Thimet 10 g granule, to control termite attack. (Repeat the treatment after 06 months, if termite persists). Flooding the pit basin with water, dressing including removal of rubbish & surplus earth, if any, with all lead & lifts , c) Supply and plantation of approved varieties of healthy, disease free, stout stem & well developed root system tree sapling of, 5-6 height, with a clear minimum height of 4-5 from basin / ground level, after plantation. Staking the tree sapling upto 3/4 height with appropriate strength of bamboo stick. Lower 1 feet of stake portion should be treated with antitermite chemical , i) Phonix Palm , ii) Red Palm , iii) Golden Palm , iv) Fox Tail Palm , v) Areca Palm , d) Maintenance of tree sapling, after plantation for 30 days or more as minimum guarantee period, for well establishment of tree sapling. Stacking to be continued till tree sapling attains the stem strength. Replacement of saplings casualties immediately , LAWM PLANTATION , a) Preparation of ground by trenching in all type of soils upto a depth of 30cm including removal & stacking of serviceable material than disposing the surplus soil with all lead & lifts, by spreading and leveling neatly. Making up the trenched area well leveled by filling with additionally supplied earth (if needed). , b) Now rough dressing of trenched ground including breaking clods & flooding with water. , c) After 10-15 days removal of weeds / unwanted grass (motha etc) with roots & disposal of uprooted material, stone rubbish etc., with all lead & lifts. , d) Then fine dressing of ground. Spreading and mixing with the good earth (excavated / imported) & manure (organic manure / cow dung / sludge) in the ratio of 8:1 (08 part of stacked volume of good earth if needed to be paid separately, after reduction of 20% of stacked volume of good earth & 8% stacked volume of manure. The area to be mixed with antitermite chemical / granules, Thimet 10G @ 100-200gm / sqmts. If termite persists repeat the treatment after 06 months by surface spreading the chemical. , e) Supply of grass and planting by dibbling the area including watering & maintenance of lawn for 30 days or more till grass forms a thick lawn cushion free from weeds , i) With Bermunda grass (15cm x 15cm apart) , ii) Carpet of grass turfing , iii) Supply & turfing of artificial lawn , iv) After ward maintenance of lawn area, green & weed free for 01 year with standard specification , SHRUB PLANTATION (SOLO) , Digging pits in all type of soils and refilling the same the good earth (excavated / imported) & manure (organic manure / cow dung / sludge) in the ratio of 5:1 (05 part of stacked volume of manure). Cost of manure / sludge and good earth if needed to be paid separately, after reduction of 20% of stacked volume of good earth & 8% stacked volume of manure. Each pit to be mixed with antitermite chemical / granules thimet 10G @50-100gms / pit , i) Pit size 0.60mts x 0.60mts (Dia x Depth) , ii) Pit size 0.45 dia x 0.60mts Depth , b) Supply & plantation of shrub and / or rose sapling to pit, appropriate stacking & initial maintenance for 30 days. Replacement of sapling casualties immediately. , c) Afterward 01 year maintenance as per standard specification , SHRUBBERY PLANTATION - (SHRUBS IN GROUPS) , Digging beds in all type of soils and refilling the same with the good earth (excavated / imported) mixed with antitermite chemical / granules @100gm/sqmts) & manure (organic manure / cow dung / sludge) in the ratio of 5:1 by volume (05 part of staked volume of good earth & 1 part of stacked volume of manure). Cost of manure / sludge and good earth if needed to be paid separately, after reduction of 20% of stacked volume of good earth &8% stacked volume of manure , i) L X W X 0.60 mts depth , b) For roses, rose mixture @500gms / sq mts to be used additionally, before plantation , c) Termite treatment - Thimet 10G granules @100 gms / Sqmts , d) Supply & plantation of shrub sapling to pit, appropriate stacking & initial maintenance , e) Afterward 01 year maintenance as per standard specification , HEDGE PLANTATION , a) Digging trenches of approved / desired size of L X W (45-50cms) X D (30-60cm) in all type of soil. Refilling the trenches with good earth (excavated / imported) mixed with manure (cowdung / sludge / dump) in the ration of 5:1 (05 part of good earth and 01 part of manure by stacked volume). Cost of manure / sludge and good earth if needed to be paid separately, after reduction of 20% of stacked volume of good earth &8% stacked volume of manure. Fore Termite treatment add Thimet 10G granules @ 100gms / running mts. Flooding the trench with water and than rough & fine dressing of trenched area including removal of undesirable weeds & vegetation. , b) Supply & plantation of approved varieties of hedge plant saplings. It should be well grown, fully established & disease free. Sapling height & density as follows , i) Hedge with sapling height -0.45 mts to 0.60mts (After Plantation) , ii) Density - @07 Nos plants / running meters (staggered condition) , c) Maintenance the hedge by regular watering, trimming & pruning etc for 30 days initially. Replacement of sapling casualties immediately , d) Afterward maintenance of hedge length for 01 (one) year as per standard maintenance specification , GROUND COVER , Digging of ground cover marked area upto a depth of 30 cms in all type of soils. Refilling the same with (excavated / supplied) good earth mixed with manure (organic / cow dung / sludge) in the ration of 8:1 (08 part of good earth *01 part of manure by stacked volume). Cost of manure / sludge and good earth if needed to be paid separately, after reduction of 20% of stacked volume of good earth & 8% stacked volume of manure. For Termite treatment add Thimet 10G granules @100 gms/Sq mts. Flooding with water the entire area. Rough & fine dressing of the ground cover bed area and removal of weeds & unwanted vegetation & its disposal , b) Supply and plantation of approved / desired ground cover plant varieties, well established, fully grown, disease free and good foliage. Plantation density should be @36 ground cover plants / square metre, or less as desired or decided by site incharge. Maintenance of all the ground cover area for 30 days till the plants establish well. , c) Regular maintenance afterward for 01 year as per standard specification , FLOWER BED PREPARATION , Digging of FLOWER BED marked area upto a depth of 30 cms (Canna Beds - 60cms depth) in all type of soils. Refilling the same with (excavated / supplied) good earth mixed with manure (organic / cowdung/ sludge) in the ration of 5:1 (05 part of good earth & 01 part of manure) . Cost of manure / sludge and good earth if needed to be paid separately, after reduction of 20% by stacked volume of stacked volume of good earth & 8% stacked volume of manure. For Termite treatment add Thimet 10G granules @100gms / sq mts. Flooding the entire with water. Rough & fine dressing the flower bed area and removal of weeds & unwanted vegetation & its disposal with all lead and lifts , a) SEASONAL FLOWERING BED SIZEFORMAL STYLE - Lx1.0mts width, INFORMAL STYLE - Any style as desired , b) Supply & plantation of seasonal flowers sapling @36 seedlings / sq mts (minimum three times in a year) , i) BUL BOUS / CUTTINGS - FLOWERING - Dahalia Plants @16 plants / Sqm) Winter , c) Maintenance of flower beds regularly upto 1 year as per standard specifications. Replacement of casualty immediately , MOUND , Preparation of mounds of various size and shape by available excavated / supplied earth in a layers not exceeding 20cm in depth, breaking clods, watering of each layer, dressing etc with all lead & lifts complete as per direction of Officer in charge. Cost of manure / sludge and good earth if needed to be paid separately, after reduction of 20% of stacked volume of good earth and 8% stacked volume of manure , BRICK EDGING , Edging with bricks (Class I) laid in PCC (1:2:4) length wise, including required excavation, refilling, consolidating withhand packing and spreading surplus earth neatly within all lead and lifts , Brick Paving : Supply and Paving of wire cut bricks on sand bed , Terracotta Pot : Terracotta Pots of height 4 & width 1m made with 8mm rod chicken mesh with cement mortar complete , PVC Pipe Line : Supply & laying of 63mm dia PVC pipeline of ISI including excavation of outlet back filling of trenches of 0.60m depth fixing with all accessories and providing outlet wherever required backfilling of trenches etc complete , Supply & erection of 2 Hp pump with all accessories including panelboard etc , Supply, erection, testing and commissioning of 1.5sqmm 3 core copper cable , GOOD EARTH / AGRICULTURE SOIL , a) Supply and stacking of good earth / agriculture soil from approved source / field ; of approved quality / pH & suitable for plantation work with all leads, lifts, carriage and royalty / taxes etc. Cost of good earthto be paid separately, after reduction of 20% of stacked volume of good earth , b) Cattle manure : Supply of cattle manure , Note:- Where Ever Written for Sand Should be Read as Manufacture Sand
Contract Date : 25 Feb, 2025   |   Contract Value : 47.47 Crore
Disclaimer

We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.

Tender Detail
Website https://tender.nprocure.com/
Quantity
MSME Exemption No
Tender Type Open Tender
Startup Exemption Click Here
Competitive Bidding NCB
Similar Tenders
TENDER INSIGHTS

858

Electric Tenders
Live
CLICK TO KNOW MAXIMUM WIN

Tell us about your Product / Services,

We will Find Tenders for you

🇮🇳 +91
TenderDetail
Loading tenders