TDR : 56299373
Gujarat Energy Transmission Corporation Limited

Tender Brief :

Amreli, Gujarat

Tender For Work of 1) Erection, commissioning of equipments , control wiring etc. of 220/132KV 150 MVA Transformer No.-3 bay for EHV class substation augmentation from 220/132 kV, 100 MVA to 220/132 kV, 150 MVA at 220KV Botad sub-station (KSY-II) 2)

Published: 03 Jul 2026
Opening: Ref Document
Closing: 27 Jul 2026
Amount: 24.98 Lakhs
EMD: 15000
Tender Fee: 1180


Works Active Harmonic Filter Actuator Aerial Cable Aerodrome Beacon Air Circuit Breaker
15
Days Left
Tender Summary / Eligibility Criteria
Work of 1) Erection, commissioning of equipments , control wiring etc. of 220/132KV 150 MVA Transformer No.-3 bay for EHV class substation augmentation from 220/132 kV, 100 MVA to 220/132 kV, 150 MVA at 220KV Botad sub-station (KSY-II) 2) Erection, commissioning and testing of 3 nos 66/11kV Transformer Bay with 66kV Bus extension work and dismantling of existing 132/11kV Transformer Bay at 132kV Barwala Substation of AM division Dhasa under Circle office Amreli
Documents Download All
4556597f97dd47c2a137bf8406e887fe
4556597f97dd47c2a137bf8406e887fe.html
T01RMworkatDhasaDivision
T01RMworkatDhasaDivision.pdf
No Boq
No Corrigendum
Probable Bidders

AI engine predicts probable bidders to help you bid strategically.

MSME Exception
Explore More →
Technical
Tender involves procurement of high capacity electrical equipment including diaphragm coupling of pump & motor with 90kW capacity at 2900 RPM. The project scope includes installation, testing, commissioning and operational handover.
Previous / Similar Result
BRR : 7212207 tender for Augmentation Work Of 132/33 Kv, 80 Mva (With Filtration Work) In Place Of 40/50 Mva Transformer At 220Kv Gss Vkia With Transportation Of Replaced 132/33 Kv 40/50 Mva Transformer At 132 Kv Gss Sitapura For Replacing The Existing 132/33 Kv 20/25 Mva - Augmentation work of132/33 KV, 80 MVA in place of40/50MVA Transformer at 220KV GSS VKIA (WBS: AUTR/23.53.01) Sl. No. Item Description 1 Work Details 2 Laying of earthing risers of 75x12 mm size M.S. Flate at a depth of .80 meter from top level of foundation including excavation of trench of required depth and backfilling of the same transportation of M.S. Rod from site store to locations,preparation of risers bendinf as per requirement (after heating if nccessary(,fixing on and welding /bolting to equipment/structure and peacks of structures layinf in the trench welding to the earth mesh of M.S Rodas per drawing,including welding of extra length of M.S.Flate ifrequired application of btumen compound and covering with bitumen impregnated tap on all welded joints,paiting of all surface of risers above ground level with red oxide and green paint, for the type of soil prevalent at0 .80 metre below top level of foundatios(M.S.Rod of above sizes&M.S.Flate as rquired shall be made available by RVPNL).a)In case electricity is made available by RRVPNL without charges.i)Any soil, soft rock other than hard rock 3 Placing/Drawing of earth electrode of 40 mm dia.M.S.Rod of length 3.30 meters(approx) to a depth of 3.80 meters from the top level of foundations, including excavation of pit as required and backfilling of the same transportion of M.S. Rod from site to locations,cutting of M.S. Rod to desired length preparation of one end as spike if necessary ,welding of earth electrode to earth mesh.OF M.S. Rod as per drawing,application of btumen compound and covering with bitumen impregnated tapon all welded joints,for the type of soil prevalent at 3.80 metres below top level of foundation (M.S.Rod of above sizes&M.S.Flat as required shall be made available bya)In case electricity is made available by RRVPNL without charges.i)Any soil, soft rock other than hard rock 4 JUMPERS of ACSR conductor(3 nos Y type)between equipment or between bus to bus,including transportion of conductor,disc insulators and hardware from site stores to locations ,cleaning and assembly of disc insulators as along with fitting of suspension hardware and erectoin as reqired, cutting reqired length of conductor, making connections,fixing of spacers & spacer T-clamps as reqired,tightiening of clamps/connectors,dressing ect. For three phases.(Per jumper basis)1)Anyconductor 5 Erection of 132 KV class EHV Transformer (Gas filled tank already placed on foundation with wheels), including transportation of accessories from site store to locations,erections of HV,IV,LV & Netural bushings, Main & OLTC conservator ,radiators,equalizing pipe line,MK etc as per Manufactures drawing preparation of oil,oil filling,dehyradation of transformer(filter machine, oil tank & operating staff shall be provided by RVPN) electrical wiring from individual equipment, e.g. Buchholz relay,MOLG,OSR etc. to Marshalling kiosk,etc. but excluding testing & commissioning of transformer.a) if electricity is available & arranged by RVPN without charges . 6 ERECTION OF SUB-STATION STEEL STRUCTURES columns, beams, lighting mast and equipment structures (excluding Circuit Breakers and Capacitor Banks) of all types including transportation of structure members, nuts & bolts, washers etc from site store to locations, their assembly, placing on foundation, fixing of template, with foundation bolts as required, levelling and preparing for grouting as required, but excluding grouting, erection after grouting and tightening & punching of nuts & bolts. (Maximum height of structures up to 20 metres) 7 ERECTION OF SUB-STATION EQUIPMENTErection of Isolators (Motorised/ Non motorised) on already erected steel structure including transportation of base frame, P Is contacts, mechanism box, clamps & connectors etc from site store to locations, minor fabrication as required and fixing of terminal connectors etc, adjustment / alignment of isolator and its earth blade, if provided for their smooth operation and final adjustment if required after jumpering including erection of PI.i) 132 KV a) Without Earth Blade 8 Erection of Current Transformer / Potential Transformer / Capacitive Voltage Transformer / Series Reactor / Residual Voltage Transformer / Neutral Current Transformer with clamps & connectors on already erected steel structure including transportation from site store to locations, fabrication of base frame, fixing of terminal connectors, tightening of nuts & bolts etc, complete in all respects. iii) 33 KV or 11 KV CT / PT 9 ERECTION OF MARSHALLING KIOSK / Line Matching Unit (LMU) / Line Matching & Distribution Unit (LMDU) complete in all respect including transportation from site store to location, placing on foundation / cable trench as per layout, preparing for grouting of foundation bolts but excluding grouting etc.i) 220 KV or 132 KV Marshlling Kiosk 10 LAYING AND TERMINATION OF CABLES.Control Cables i)Laying of PVC insulated unarmored /armored control cables of 1.1 kv grade with copper condutor in cable trenches as per sepecification as required, including transportion of cable drum from site store to locations,cutting to required length,placing them on cable racks/cable trays/ cable batten and dressing,including removing and re-fixing trench covers as required, making necessary connections testing,cable marking on both termimating ends,ets.as required for all size from 2cx2.5 sq.to 20x2.5 sq mm & 4x4 sq mm and 4cX6 sq. mm.a)Unarmored control cable 11 ii) Fixing of control cable in position with single compression nickle plated brass cable glands confirming to IS 12943 & having three metal washers and one rubber ring including preparion of cables and drilling of corresponding holes in gland plated etc as reuired & including cost of cable glands,for each gland sizes.a) 19 mm Unarmored control cable 12 b) 25 mm Unarmored control cable 13 c) 32 mm Unarmored control cable 14 iii) Termination of wires of cables with copper conductor using copper terminal ends (pin or ring type as required of Dowell,s or equivalent make as approved by the Engineer-In-charge) duly cnmped with crimping tool,including making wire ends ready for crimping ferruling & dressing of wire etc as required including cost of terminal ends for all wires for each cable al lboth ends for cables of the following sizes.2.5 sq.mm For any number of core 15 4 sq.mm For any number of core 16 Erection of control &Relay panels complete in all rsepects including transportion from site store to control room,placing on foundation/cable trench as per layout,interconnection between control&Realy panels and with existing panels,fixing of side/top cov per layout,interconnection between control & Realy per layout,interconnection between control&Realy per layout,interconnection between control&Realypanels and with existing panels,fixing of side/top covers and doors,earthing to existing earth strip in control room,connection of bus wiring to existing panel and between control and realy as requirediii) Simplex panel,DC panel,RTCCpanel,PLCC panel etc. 17 Dismentaling of132KV EHV TransformerGas filled tank already placed on foundation with wheels), including transportation of accessories from site store to locations,erections of HV,IV,LV & Netural bushings, Main & OLTC conservator ,radiators,equalizing pipe line,MK etc as per Manufactures drawing preparation of oil,oil filling,dehyradation of transformer(filter machine, oil tank & operating staff shall be provided by RVPN) electrical wiring from individual equipment, e.g. Buchholz relay,MOLG,OSR etc. to Marshalling kiosk,etc. but excluding testing & commissioning of transformer.a) if electricity is available & arranged by RVPN without charges . 18 Dismentaling of JUMPERS of ACSR conductor(3 nos Y type)between equipment or between bus to bus,including transportion of conductor,disc insulators and hardware from site stores to locations ,cleaning and assembly of disc insulators as along with fitting of suspension hardware and erectoin as reqired, cutting reqired length of conductor, making connections,fixing of spacers & spacer T-clamps as reqired,tightiening of clamps/connectors,dressing ect. For three phases.(Per jumper basis)1)Anyconductor 19 Dismentaling of Current Transformer / Potential Transformer / Capacitive Voltage Transformer / Series Reactor / Residual Voltage Transformer / Neutral Current Transformer with clamps & connectors on already erected steel structure including transportation from site store to locations, fabrication of base frame, fixing of terminal connectors, tightening of nuts & bolts etc, complete in all respects.iii) 33 KV or 11 KV CT / PT 20 Erection of control &Relay panels complete in all rsepects including transportion from site store to control room,placing on foundation/cable trench as per layout,interconnection between control&Realy panels and with existing panels,fixing of side/top covers and doors,earthing to existing earth strip in control room,connection of bus wiring to existing panel and between control and realy as required iii) Simplex panel,DC panel,RTCC panel,PLCC panel etc. 21 Transportation Charges of Truck for 132/33 KV, 40/50 MVA Transformer 22 LoadingCharges of 132/33 KV, 40/50 MVA Transformer from old location 23 Unloading Charges of 132/33 KV, 40/50 MVA Transformer at New location 24 Dragging charges for 132/33 KV, 40/50 MVA Transformer from old location to track and track to new location 25 Filtration of Transformer oil of 132/33 KV, 80 MVA Power Transformerat 220 KV GSS VKIA (Jaipur) by providing High vacuum Filtration machine and oil testing kit, having 100kV capacity.
Contract Date : 07 Apr, 2025   |   Contract Value : 8.44 Lakhs
BRR : 8644695 Tender For Augmentation Work Of 220/132 Kv, (+) 200 Mva (-) 100 Mva Power Transformerat 220 Kv Gss Rvpn Mandawar (Dausa) - Laying of earth mesh with 25mm / 28mm dia M.S. Rod at a depth of 0.80 metre from top level of foundation, including excavation of trench of required depth and backfilling of the same, transportation of M.S. Rods from site store to location, welding of M.S. Rod to M.S. Rod along the length, at crossings and with earth electrodes as per drawing, application of bitumen compound and covering with bitumen impregnated tape on all welded joints, for the type of soil prevalent at 0.80 metre below top level of foundations (M.S. Rod of above sizes & M.S. Flat as required shall be made available by RVPN).(a) In case electricity is made available by RVPN without charges. i) Any soil, soft rock other than hard rock 2 Laying of earthing risers of 50x6mm / 50x10mm / 50x12mm size M.S. Flat at a depth of 0.80 metre from top level of foundations, including excavation of trench of required depth and back filling of the same, transportation of M.S. Flat from site store to locations, preparation of risers, bending as per reqiurement (after heating if necessary), fixing on & belding / bolting of equipment / structure & peaks of structure, laying in the trench, welding to earth mesh of M.S. Rod as per drawing, including welding of extra length of M.S. Flat if required, application of bitumen compound and covering with bitumen impregnated tape on all welded joints, painting of all surfaces of risers above ground level with red oxide and green paint, for the type of soil prevalent at 0.80 metre below top level of foundations (M.S. Rod of above sizes & M.S. Flat as required shall be made available by RVPN).(a) In case electricity is made available by RVPN without charges.i) Any soil, soft rock other than hard rock 3 Placing / Driving of earth electrode of 25 / 28mm dia. M.S. Rod of length 3.30 metres (approx.) to a depth of 3.80 metres from the top level of foundations, including excavation of pit as required and back filling of the same, transportation of M.S. Rod from site store locations, cutting of M.S. Rod to desire length, preparation of one end as as spike if necessary, welding of earth electrode to earth mesh of M.S.Rod as per drawing, application of bitumen compound and covering with bitumen impregnated tape on all welded joints, for the type of soil prevalent at 3.80 mtrs below top level of foundations (M.S. Rod of above sizes & M.S. Flat as required shall be made available by RVPN).(a) In case electricity is made available by RVPN without charges. i) Any soil, soft rock other than hard rock 4 ERECTION OF SUB-STATION STEEL STRUCTURES columns, beams, lighting mast and equipment structures (excluding Circuit Breakers and Capacitor Banks) of all types including transportation of structure members, nuts & bolts, washers etc from site store to locations, their assembly, placing on foundation, fixing of template, with foundation bolts as required, levelling and preparing for grouting as required, but excluding grouting, erection after grouting and tightening & punching of nuts & bolts. (Maximum height of structures up to 20 metres) 5 STRINGING of 220KV, 132KV, 33KV & 11KV Bus Bar of ACSR & Tarantulla conductor including transportation of conductor, disc insulator & tension hardware from site store to location, laying & cutting required length of conductor, cleaning & assembly of disc insulators as required along with fitting of bolted type or compression type tension hardware as made availablebetween the beams with specified sag and tension, also equilising sag and fitting spacers and spacer T-clamps for twin conductor for three phase of conductors in each sub-section.(Per jumper basis) i) Any Single Conductor 6 STRINGING of 220KV, 132KV, 33KV & 11KV Bus Bar of ACSR & Tarantulla conductor including transportation of conductor, disc insulator & tension hardware from site store to location, laying & cutting required length of conductor, cleaning & assembly of disc insulators as required along with fitting of bolted type or compression type tension hardware as made availablebetween the beams with specified sag and tension, also equilising sag and fitting spacers and spacer T-clamps for twin conductor for three phase of conductors in each sub-section.(Per jumper basis)i) Any Double Conductor 7 JUMPERS of ACSR conductor (3 nos. Y-type) between bus to equipment or between equipment to equipment or between bus to bus, including transportation of conductor, disc insulators and hardware from site stores to locations, cleaning & assembly of disc insulators as required along with fitting of suspension hardware and erection as required length of conductor, making connections, fixing of spacers & spacer T-clampsas required, tightening of clamps / connectors, dressing etc., for three phases.(Per jumper basis) 8 STRINGING of earth wire (size 7/3.15 mm or 7/4.00 mm) including transportation of earth wire, tension hardwares etc from site store to locations, laying and cutting required length of earth wire, fitting of bolted type or compression type hardware as made available (compression machine shall be provided by RVPN on rent free basis) making up at one end, stringing of earthwire between structure peaks with specified sag and tension, jumpering and connecting earth bonds for single earthwire. 9 Erection of Current Transformer / Potential Transformer / Capacitive Voltage Transformer / Series Reactor / Residual Voltage Transformer / Neutral Current Transformer with clamps & connectors on already erected steel structure including transportation from site store to locations, fabrication of base frame, fixing of terminal connectors, tightening of nuts & bolts etc, complete in all respects. i) 220 KV CT / PT / CVT 10 Erection of Current Transformer / Potential Transformer / Capacitive Voltage Transformer / Series Reactor / Residual Voltage Transformer / Neutral Current Transformer with clamps & connectors on already erected steel structure including transportation from site store to locations, fabrication of base frame, fixing of terminal connectors, tightening of nuts & bolts etc, complete in all respects. ii) 132 KV CT / PT / CVT 11 Erection of Lightening Arrestor on already erected steel structure including transportation of Lightening Arrestor, clamps & connectors, surge counter etc from site store to locations, fabrication of base frame, fixing of terminal connectors, surge counter, tightening of nuts & bolts etc, complete in all respects.ii) 220 KV 12 Erection of Lightening Arrestor on already erected steel structure including transportation of Lightening Arrestor, clamps & connectors, surge counter etc from site store to locations, fabrication of base frame, fixing of terminal connectors, surge counter, tightening of nuts & bolts etc, complete in all respects.ii) 132 KV 13 Erection of 220 KV Isolators (Motorised/ Non motorised) on already erected steel structure including transportation of base frame, P Is contacts, mechanism box, clamps & connectors etc from site store to locations, minor fabrication as required and fixing of terminal connectors etc, adjustment / alignment of isolator and its earth blade, if provided for their smooth operation and final adjustment if required after jumpering including erection of PI.a) Without Earth Blade 14 Erection of 1220 KV Isolators (Motorised/ Non motorised) on already erected steel structure including transportation of base frame, P Is contacts, mechanism box, clamps & connectors etc from site store to locations, minor fabrication as required and fixing of terminal connectors etc, adjustment / alignment of isolator and its earth blade, if provided for their smooth operation and final adjustment if required after jumpering including erection of PI.a) Tandem 15 Erection of 132 KV Isolators (Motorised/ Non motorised) on already erected steel structure including transportation of base frame, P Is contacts, mechanism box, clamps & connectors etc from site store to locations, minor fabrication as required and fixing of terminal connectors etc, adjustment / alignment of isolator and its earth blade, if provided for their smooth operation and final adjustment if required after jumpering including erection of PI.b) WithoutEarth Blade 16 Erection of 220 KV or 132 KV Circuit Breaker including transportation of equipments, structure members, nuts & bolts, clamps & connectors etc from site store to locations, assembly of support structure, their placing on foundation, levelling and preparing for grouting as required, but excluding grouting, assembly / placing of support coulmns / poles, mechanism box / control cubicle, and other accessories as per manufacturers drawings, fitting of SF6 gas pipeline, fabrication of air/ oil pipeline as required, electrical wiring from pole to control cubicle, fixing of terminal connectors as required, but excluding commissioning of CB for all types of operating mechanism as required. (i) 220 KV 17 Erection of 220KV Class EHV Transformer (Gas filled tankalready placed on foundation with wheels) including transportation of accessories from site store to locations, erection of HV, IV, LV & Neutral bushings, main & OLTC conservators, radiators, equilizing pipe line, marshalling kisok etc as per manufacturers drawing, preparation of oil, oil filling, dehydration of transformer (filter machine, oil tank & operating staff shall be provided by RVPN), electrical wiring from individual equipment e.g. Buchholz Relay, MOLG, OSR etc to marshalling kiosk etc but excluding testing & commissioning of transformer.(a) If electricity is available & arranged by RVPN without charges. i) Transformer received Oil filled 18 ERECTION OF CONTROL & RELAY PANALS complete in all respects including transportation from site store to control room, placing on foundation / cable trench as per layout, interconnection between Control & Relay panels and with existing panels, fixing of side / top covers and doors, earthing to existing earth strip in control room, connection of bus wiring to existing panel and between control and relay panel as required.ii) Duplex Panel 19 ERECTION OF CONTROL & RELAY PANALS complete in all respects including transportation from site store to control room, placing on foundation / cable trench as per layout, interconnection between Control & Relay panels and with existing panels, fixing of side / top covers and doors, earthing to existing earth strip in control room, connection of bus wiring to existing panel and between control and relay panel as required. iii) Simplex Panel, DC Panel, RTCC Panel, PLCC Panel etc 20 ERECTION OF MARSHALLING KIOSK / Line Matching Unit (LMU) / Line Matching & Distribution Unit (LMDU) complete in all respect including transportation from site store to location, placing on foundation / cable trench as per layout, preparing for grouting of foundation bolts but excluding grouting etc. i) 220 KV or 132 KV Marshlling Kiosk 21 i) Laying of PVC insulated unarmoured / armoured control cables of 1.1 KV grade with copper conductor in cable trenches as per specification as required, including transportation of cable drums from site store to locations, laying in cable treches, cutting of required length, placing them on cable racks / cable trays / cable batten & dressing, including removing and re-fixing trech covers as required , making necessary connections, testing, cable marking on both the terminating ends etc as required for all sizes from 2C x 2.5 sq. mm. to 20C x 2.5 sq. mm, 4C x 4 sq. mm and 4C x 6 sq. mm.a) Unarmoured control cable 22 ii) Fixing of control cable in position with single compression nickel plated brass cable glands confirming to IS: 12943 & having three metal washers and one rubber ring, including preparation of cable and drilling of corresponding holes in gland plates etc as required & including cost of cable glands for each cable gland size a) 19 mm unarmoured control cable 23 ii) Fixing of control cable in position with single compression nickel plated brass cable glands confirming to IS: 12943 & having three metal washers and one rubber ring, including preparation of cable and drilling of corresponding holes in gland plates etc as required & including cost of cable glands for each cable gland sizec) 25 mm unarmoured control cable 24 iii) Termination of wires of cables with copper conductor using copper terminal ends (pin or ring type as required of Dowells or equivalent make as approved by the Engineer - In - Charge) duly crimped with crimping tool, including making wire ends ready for crimping, ferruling & dressing of wires etc as required including cost of terminal ends for all wires for each cable at both ends for cables of the following sizes.a) 2.5 Sqmm for any number of core 25 iii) Termination of wires of cables with copper conductor using copper terminal ends (pin or ring type as required of Dowells or equivalent make as approved by the Engineer - In - Charge) duly crimped with crimping tool, including making wire ends ready for crimping, ferruling & dressing of wires etc as required including cost of terminal ends for all wires for each cable at both ends for cables of the following sizesb) 4 Sqmm for any number of core 26 Dismentaling of 220KV, 132KV, 33KV & 11KV Bus Bar of ACSR & Tarantulla conductor including transportation of conductor, disc insulator & tension hardware from site store to location, laying & cutting required length of conductor, cleaning & assembly of disc insulators as required along with fitting of bolted type or compression type tension hardware as made availablebetween the beams with specified sag and tension, also equilising sag and fitting spacers and spacer T-clamps for twin conductor for three phase of conductors in each sub-section.(Per jumper basis) 27 Dismentaling of JUMPERS of ACSR conductor(3 nos Y type)between equipment or between bus to bus,including transportion of conductor,disc insulators and hardware from site stores to locations ,cleaning and assembly of disc insulators as along with fitting of suspension hardware and erectoin as reqired, cutting reqired length of conductor, making connections,fixing of spacers & spacer T-clamps as reqired,tightiening of clamps/connectors,dressing ect. For three phases.(Per jumper basis) any conductor 28 DISMENTELLING of Current Transformer / Potential Transformer / Capacitive Voltage Transformer / Series Reactor / Residual Voltage Transformer / Neutral Current Transformer with clamps & connectors on already erected steel structure including transportation from site store to locations, fabrication of base frame, fixing of terminal connectors, tightening of nuts & bolts etc, complete in all respects. 220 KV CT/PT/CVT 29 DISMENTELLING of Current Transformer / Potential Transformer / Capacitive Voltage Transformer / Series Reactor / Residual Voltage Transformer / Neutral Current Transformer with clamps & connectors on already erected steel structure including transportation from site store to locations, fabrication of base frame, fixing of terminal connectors, tightening of nuts & bolts etc, complete in all respects. 132 kvCT/PT/CVT 30 Dismental of lightening Arrestor on already erected steel structure including transportion of lighting Arre-stor,clamps&connectors,surge counter etc. from site store to locations fabrication of base frame,fixing of terninal connectors surge counter, tighting of nuts&bolts etc. complete in all respect. (I) 220 kv 31 Dismental of lightening Arrestor on already erected steel structure including transportion of lighting Arre-stor,clamps&connectors,surge counter etc. from site store to locations fabrication of base frame,fixing of terninal connectors surge counter, tighting of nuts&bolts etc. complete in all respect. (ii) 132 KV 32 DISMENTELLINGof Isolators (Motorised/ Non motorised) on already erected steel structure including transportation of base frame, P Is contacts, mechanism box, clamps & connectors etc from site store to locations, minor fabrication as required and fixing of terminal connectors etc, adjustment / alignment of isolator and its earth blade, if provided for their smooth operation and final adjustment if required after jumpering including erection of PI. (I) 220 KVWITHOUT EARTH BLADE 33 DISMENTELLINGof Isolators (Motorised/ Non motorised) on already erected steel structure including transportation of base frame, P Is contacts, mechanism box, clamps & connectors etc from site store to locations, minor fabrication as required and fixing of terminal connectors etc, adjustment / alignment of isolator and its earth blade, if provided for their smooth operation and final adjustment if required after jumpering including erection of PI. (I) 220 KVTANDEM 34 DISMENTELLINGof Isolators (Motorised/ Non motorised) on already erected steel structure including transportation of base frame, P Is contacts, mechanism box, clamps & connectors etc from site store to locations, minor fabrication as required and fixing of terminal connectors etc, adjustment / alignment of isolator and its earth blade, if provided for their smooth operation and final adjustment if required after jumpering including erection of PI. (I) 132 kv w/o EARTH BALDE 35 Dismentalof 220 KV Circuit Breaker including transportation of equipments, structure members, nuts & bolts, clamps & connectors etc from site store to locations, assembly of support structure, their placing on foundation, levelling and preparing for grouting as required, but excluding grouting, assembly / placing of support coulmns / poles, mechanism box / control cubicle, and other accessories as per manufacturers drawings, fitting of SF6 gas pipeline, fabrication of air/ oil pipeline as required, electrical wiring from pole to control cubicle, fixing of terminal connectors as required, but excluding commissioning of CB for all types of operating mechanism as required. 36 Dismantlingof 220 KV Class EHV Transformer (Gas filled tank already placed on foundation with wheels ) including transportation of Accessories from site store to location , Erection of HV , IV , LV & Netural bussing tank already placed on foundation with wheels) including transportation of accessories from site store to locations, erection of HV, IV, LV & Neutral bushings, erection of cooler bank with associated pipe line , radiators , fans , pumps main & OLTC Conservators , Equalizing pipe line , marshalling Kisosk , etc. as per manufacturers drawing prepration of oil , oil filling , dehydration of transformer along with cooler bank & diverter switch(filter machine, oil tank & operating staff shall be provided by RVPN), electrical wiring from individual equipment e.g. Buchholz Relay, MOLG, OSR etc to marshalling kiosk etc but excluding testing & commissioning of transformer. 37 Dismentling ofCONTROL & RELAY PANALS complete in all respects including transportation from site store to control room, placing on foundation / cable trench as per layout, interconnection between Control & Relay panels and with existing panels, fixing of side / top covers and doors, earthing to existing earth strip in control room, connection of bus wiring to existing panel and between control and relay panel as required. Duplex panel 38 Dismentling ofCONTROL & RELAY PANALS complete in all respects including transportation from site store to control room, placing on foundation / cable trench as per layout, interconnection between Control & Relay panels and with existing panels, fixing of side / top covers and doors, earthing to existing earth strip in control room, connection of bus wiring to existing panel and between control and relay panel as required. 9ii) Simplex Panel, DC Panel, RTCC panel, PLCC Panel etc
Contract Date : 31 Oct, 2025   |   Contract Value : 11.60 Lakhs
BRR : 9239864 Tender For Augmentation of 400 kV substation Dhanonda, Nawada and Kirori-- 1 500 MVA,400/220/33kV, 3 Phase Auto Transformer excluding insulating oil 2 Insulating oil for 500 MVA,400/220/33kV, 3 Phase Auto Transformer (including 10% extra oil) 3 Digital RTCC Panel consist of digital RTCC relays 4 BDV testing Kit 5 Tool Kit 6 420kV circuit breakers (3 Ph.) with support structures 3150 A, 63 KA without closing resistor 7 420kv (6core) CT (1 Ph.)- for main bay & tie bayRatio- 3000-2000-500/1-1-1-1-1-1A, 63 KA 8 420kV Isolators (double break type)i) 3150A, 63 KA, isolator with one E/S 9 ii) 3150 A, 63 kA, isolator with both side E/S 10 336 kV Surge Arrester (Gapless), 63 KA 11 420kV Bus Post Insulator 12 400 KV C&R Panels (Simplex type)- SAS CompliantCircuit Breaker control panel without Auto Reclose and transformer Protection Panel (For HV side) with peripheral relay for bus bar protection on 400kV side. 13 Circuit breaker control panel with Auto Reclose and Tie protection panel with P.U. of future line bay 14 i) Extension of existing Fire Protection System (As per technical specification) for 500 MVA Auto-Transformer at 400kV sub-station as per site requirement is in the scope of bidder. 15 245 kV Circuit Breakers(3 ph)i) 2500 A, 50 kA 16 245 kV T/F I/C CT (1 ph) 50 kA with(I/C T/F CT ) (Ratio 1600-800/1-1-1-1-1A) 17 245 kV Isolator (3 ph) Double break2500A,50 kA,Isolator 18 220 kV Surge arrestors216kV, 50KA 19 245kV Bus Post Insulator 20 220 kV C&R Panels -SAS CompliantCircuit Breaker control panel without Auto Reclose for T/F I/C for 500MVA, 400/220kV T/F with peripheral relay for bus bar protection on 220kV side 21 220 kV C&R Panels -SAS CompliantCircuit Breaker control panel without Auto Reclose and transformer protection incomer panel (for LV side) with peripheral relay for bus bar protection on 220kV side 22 Supply and installation of 2 fittings of 240W LED lamps with all accessories for Complete lighting of outdoor Switch yard area including all accessories, cables etc. as per HVPNL Technical specification . 23 Power cables (XLPE & PVC) as per site requirements. 24 Complete substation automation system for 400/220 kV substations including hardware (along with transducers) & software, if required for present scope of work ( 1 no.500 MVA 400/220/33 kV T/F Bay(Refer Note 2 also) 25 Armoured copper control cables (PVC) of various sizes e.g. 7Cx4mm2, 4Cx4mm2, 2Cx4mm2, 2Cx6mm2, 3Cx2.5mm2, 7Cx2.5mm2, 10Cx2.5mm2 & 16Cx2.5mm2 and as specified in relevant technical specifications, with juction box for 400 kV & 220 kV side with associated accessories like clamps, PVC ferrules, glands, lugs, fibre cleat/aluminium clamp/bolt/washers etc. as per specification. 26 Dismantlement & re-erection of 220kV line Bay along with all material including equipments and support structures from A-8 to A-7 at 400KV Substation Kirori complete in all respect with disconnection of the existing cable & rewiring after erection, testing & commissioning with SCADA integration, PLCC wiring etc.a) 220 kV Circuit Breaker 27 b) 220 kV Current Transformer 28 c) Isolators 29 d) Isolators with Earth Switch 30 e) 220 kV CVT 31 f) 220 kV LA 32 g) 220 kV PI 33 h) 220 kV C&R Panel 34 i) 220 kV Wave Trap 35 j) 220 kV MK 36 k) All the above equipments alongwith associated support structures, jumpers, hardware fittings, conductor etc. as per site 37 Bolted type 400 kV Double tension string assembly with Silicon rubber Polymer Composite Insulators (E&M strength 120 KN) with all hardware accessories including ball & socket connection accessories for Twin Tarantulaconductor (string). 38 Bolted type 400 kV single suspension string assembly with Silicon rubber Polymer Composite Insulators (E&M strength 120 KN) with all hardware accessories including ball & socket connection accessories for Twin Tarantulaconductor (string). 39 Bolted type 220 kV single suspension string assembly with Silicon rubber Polymer Composite Insulators (E&M strength 90 KN) with all hardware accessories including ball & socket connection suitable for Twin Tarantula (string). 40 Bolted type 220 kV Single tension string assembly with Silicon Rubber Polymer Composite Insulators (E&M strength 90 KN) with all hardware accessories including ball & socket connections and tension clamp sets suitable for Twin Tarantula (string). 41 Earthing material – 40mm MS rod & G.I. earthing flat for connecting all the equipments with existing main earthmat, risers & independent earthing of T/F up to water level.Suitable arrangements as per actual site conditions shall be made to take care of 63kA fault level as per technical specification and IEEE-80. 42 Galvanized iron perforated tray with side coupler plate bolts, nuts, washers and clamps etc. of size 150x25x2 mm, 100x25x2 mm and 75x25x2 mm and G.I conduits of 50/100mm diameter from equipment to main trench as per technical requirement. 43 Clamps & connectors including equipment connectors, cable supporting angles/channels, cables, C-Wedge connectors, spacers, lug glands, firefighting equipment ,Junction box,Pipes for equipments and lighting, lighting PVC ferrules all accessories etc. as per GELO and specification. 44 4.5 IPS AI tube alongnwith all accessories e.g. welding sleeves, corona cap, terminal connector for BPI, inter connector, BPI etc. (all as per site requirement) 45 Tarantula Conductor 46 GS Earth wire (7/3.66) as per specification 47 U-bolt 20mm dia 48 Bay marshalling Kiosk with mounting structure for 400kV side (Front side with 350 tb for control circuit and rear side power circuit) 49 Bay marshalling Kiosk with mounting structure for 220kV side (Front side with 300 tb for control circuit and rear side power circuit) 50 Item for associated Structure work‘Lattice Type Steel Structure. Supply of material, preparation of fabrication drawing, galvanizing and delivery of lattice type steel structure for tower and beams for 400/220kV switchyard fabricated from steel conforming to IS:2062 including nuts-bolts gusset plates foundation bolts and other accessories as per drawings supplied by the owner.* For 220 kV Lattice Structure (Standard) mentionedbelow Although the equipment structures are standardized as mentioned below, however, in case specific requirement of fitment of structures is not met with these standardized 220KV structures in that case the Design & Engineering of the equipment structures for 220KV equipments (lattice type / pipe type, as applicable) shall be in in the scope of the successful bidder. Further, the Design & Engineering cost of these support structures shall also deemed to be included in the supply cost of these equipment structures.Main substation Tower and beamTower type AT-1 51 Tower type AT-3 52 Beam Type AB-1 53 400 kV Pipe Structures (Standard)CT (Drg. No. HTD/ST-197) 54 Isolators ( Drg. No. HTD/ST-196) 55 Surge Arrestor (Drg. No. HTD/ST-195) 56 BPI(Drg. No. HTD/ST-193) 57 220 kV Lattice Structure (Standard)CT (Drg. No. HTD/ST-147) 58 Isolators (Drg. No. HTD/ST-170) 59 BPI (Drg. No. HTD/ST-116 R3) 60 Surge Arrestor( Drg. No. HTD/ST-93 R) 61 LIST OF MANDATORY SPARES FOR 400kV DHANONDA, 400kV NAWADA and 400kV KIRORI420 kV SF-6 circuit Breakeri.One pole complete without closing resistor, grading capacitor (if applicable) complete with column and interrupter with MB & operating mechanism and without support structure 62 ii.SF-6 Gas (40% of ordered quantity) 63 iii.Trip coil with resistor 64 iv.Closing coil with resistor 65 v.Terminal pad and connectors 66 vi.Molecular filter for SF6 Ckt for 1 pole of CB 67 vii.Density /pressure monitor for SF-6CKt for 1 pole of ckt breaker 68 viii.Corona rings of each type 69 ix.Fixed moving and arching contacts including insulating nozzels for one pole of CB 70 x. Relays, power contractors, switch fuse units, limit switches, push buttons, timers and MCBs etc. (1 no of each type) 71 xi. Closing Coil assembly 72 xii. Trip Coil assembly 73 xiii. Set of control valves (of each type) 74 xiv. Pressure switches of each type ( 1 CB) 75 xv. Pressure Gauge with coupling device of each type 76 xvi. Aux contact assembly 77 xvii. Operation counter 78 xviii. All type of coupling for SF6 gas 79 xix. Rubber Gasket “O Ring” and seal (complete replacement for 1 phase of 420kV SF6 Circuit Breaker 80 Spring Operating Mechanism (if applicable)i. Complete Spring Operating Mechanism 81 ii. Closing Dashpot 82 iii. Opening Dashpot 83 iv. Opening Catch Gear 84 v. Closing Catch Gear 85 420 kV Double Break Isolatori. One complete pole with support insulators excluding structure & motor operating mechanism 86 ii. Copper contact fingers for female & male contacts 87 iii. Terminal pad with connectors 88 iv. Relays, power contactors, MCBs switch fuses, push buttons and resistors for electrical control ckt as per approved schematic 89 v. Timers. Key interlock, push button switch, limit switch, aux. switches, corona shield, motor having bearing assembly etc. 90 vi. Support Insulator 91 336 kV Surge Arresteri. 336 kV Surge Arrester complete with Insulating base and terminal connectors 92 ii. Surge Counters/monitors 93 Transformers protection panel sparesi. Transformers differential protection relay including all aux. CTs 94 ii. Restricted earth fault protection relay with non-linear resistor 95 iii. Back up for protection relay with 3 O/C and E/F element 96 iv. Over fluxing relay, if separate relay is provided in the approved C&R panel 97 v. Over load spare relay with timer, if separate relay is provided in the approved C&R panel 98 Substation Automation Systemi. Intelligent electronics device (IED) 99 ii. Set of each type optic fire cables of length of longest section used 100 iii. Set of connectors (one of each type) for optic fibre cables 101 iv. Ethernet switch 102 420 kV CT 103 245kV SF-6 CktBreakeri. One pole complete withof 2500 A CB with pole column and interrupter with MB & operating mechanism, grading capacitor (if required) and without support structure 104 ii. “O” rings, gaskets, Seals for operating mechanism 105 iii. Trip coil with resistor 106 iv. Closing coil with resistor 107 v. Terminal pad and connectors 108 vi. Molecular filter for SF6 Ckt for 1 pole of CB 109 vii. Density /pressure monitor for SF6 ckt for 1 pole of ckt breaker 110 viii.Corona ring of each type 111 ix. Fixed moving and arcing contacts including insulating nozzles for one pole of CB. 112 x. Relays, power contractors , switch fuse units , limit switches , push buttons m, timers and MCBs etc 113 xi. Closing Coil assembly 114 xii. Trip Coil assembly 115 xiii. Set of control Valve (of each type) 116 xiv. Pressure switches with (1 CB) 117 xv. Pressure gauges with coupling device of each type 118 xvi. Aux switch assembly 119 xvii. Operation counter 120 xviii. All type of coupling for SF6 Gas 121 Spring Operating Mechanism (if applicable)xix.Complete Spring Operating Mechanism 122 xx. Closing Dashpot 123 xxi. Opening Dashpot 124 xxii. Opening Catch Gear 125 xxiii. Closing Catch Gear 126 245 kV Double break isolatori. One complete pole of 245 KV 2500A Isolator along with support insulators & operating mechanism. 127 ii. Copper contact fingers for female & male contacts. 128 iii. Terminal pad with connectors 129 iv. Relays, power contactors, switch tests & push buttons 130 v. Motor with gear assembly and bevel gear assembly 131 vi. Hinge pins 132 vii. Corona shield rings 133 viii. Bearing 134 ix. Current Carrying assembly 135 x. Limit switch 136 216 kV Surge Arrester216 KV Surge Arrester Complete with Insulating base and terminal connectors 137 Surge Counters 138 220 kV T/F I/C CT 139 LIST OF MANDATORY SPARES FOR 500 MVA AUTO TRANSFORMER (AS APPLICABLE)Oil cooler pump with motor 140 Buchholz relay complete with float and contacts (main Tank) 141 Local & remote WTI complete with sensing device & contacts 142 Oil temperature indicators with contacts & sensing device 143 Pressure relief device 144 Magnetic oil level gauge 145 Cooler fan with motor 146 Starters, contactors, switches & relays for electrical control panels (one set of each type) 147 Set of valves (complete set for one transformer) 148 Fuses & MCBs ( one set complete for replacement for one transformer) 149 Oil sampling bottles (Stainless Steel, 1 Ltr) 150 Oil storage tank (15 KL) 151 Indicating Lamps (1Set consisting of complete replacement for one transformer). 152 Aux. Transformer for control of cooler control cabinet and OLTC (if applicable) 153 Breather assembly (one of each type ) for conservator and OLTC 154 Remote tap position indicator 155 Oil flow indicator with flow switch 156 Oil surge relay for OLTC 157 420kV Bushing with metal parts, gasket and lifting tools 158 245kV Bushing with metal parts & gasket 159 52kV Bushing with metal parts & gasket (if applicable) 160 Neutral Bushing with metal parts & gasket 161 Cartridge for Online insulating oil drying system. 162 1. FoundationsSupply of labour, T&P, material and construction of RCC footings & pedestals etc. for steel gantry and equipment structures complete in all respects as per technical specifications & drawings attached with the tender document including cost of excavation, concreting, cement, reinforcement steel, form work, grouting, holding down bolts, backfilling etc.and other items not mentioned herein but required for the completion of work. Surplus earth, if any shall be disposed off to a suitable place within the substation as per direction of engineer incharge without any extra cost. For 220kV Lattice Structure foundation*Although the equipment structures are standardized as mentioned at electrical BOQ (Section-1), however, in case specific requirement of fitment of structures is not met with those standardized 220KV structures in that case the Design & Engineering of the equipment structures along with the foundation for 220KV equipments (lattice type / pipe type, as applicable) shall bein the scope of the successful bidder. Also Design Engineering cost of foundationsshalldeemed to be included in the quoted rates.A. Gantry Towersi) AT-1 163 ii) AT-3 164 B. Equipment400 kV sidei) 400kV CT 165 ii) 400kV L&E/Isolator 166 iii) 400kV LA 167 iv) 400kV Post 168 220 Kv Side i) 220 kV LA 169 ii) 220kV CT 170 iii) 220kV Post 171 iv) 220kV L&E/Isolator 172 v) 220kV CVT 173 2. Breaker Foundation Design, engineering, supply of labour, material for construction of breaker foundations including all associated works such as PCC, RCC, structural steel, steel reinforcement, form work etc. or any other items not specifically mentioned herein but required for completion of work as per approved equipment(s) and technical specifications. Surplus earth, if any shall be disposed off to a suitable place within the substation as per direction of engineer incharge without any extra cost.i) 400 kV Circuit Breaker 174 ii) 220kV Circuit Breaker 175 3. Transformer Foundation i) Design, Engg., supply of labour, material and construction of T/F foundation including radiator foundations etc. complete transformer foundations including all associated works, RCC, PCC, Reinforcement steel, misc. structural steel and other items not mentioned herein but required for the completion of work as per technical specifications. In case additional foundation is/are required as per approved equipment drawing, the same shall be constructed by the successful bidder without any extra cost to HVPNL. Such drawing(s) shall, however, be got approved from HVPNL. Surplus earth, if any shall be disposed off to a suitable place within the substation as per direction of engineer incharge without any extra cost.500MVA,400/220/33kV T/F block foundation including radiator foundation and oil pitsystem etc. complete in all respect 176 4. OUTDOOR CABLE TRENCHESSupply of labour, material such as cement, reinforcement steel, GI angles, flats, PCC & brick pillars below cable trenches for construction of Out-Door Cable Trenches (ODCT) of required depth/ type with pre-cast RCC covers including associated works as per approved Trench layout plan, HVPNL drgs. & tech. specs. complete in all respect. Surplus earth, if any shall be disposed off to a suitable place within the substation as per direction of engineer incharge without any extra cost.i) D-Type Trench 177 ii) E-Type Trench 178 iii) F-Type Trench 179 iv) G-Type Trench 180 v) Trench Culvert 181 5. Site Surfacing5.1 PCC WITH GRAVEL (FRESH)Providing, supplying & laying 100mm thick PCC (1:4:8) using 20mm nominal coarse aggregates & spreading 100mm thick layer of 40mm nominal size uncrushed/crushed/broken stone/ pebbles over the PCC including construction of toe wall (exposed wall plastered with cement mortar 1:5) to hold 40mm size uncrushed/crushed/ broken stone/pebbles wherever required in the bays covered under the present scope as detailed in the GELO & instructions of engineer incharge. 182 5.2 ONLY GRAVELProviding, supplying & laying 100mm thick in two layers of 50mm each of 20mm nominal size uncrushed/crushed/ broken stone pebbles gravel fill including dressing, rolling & compacting complete in all respects as per specs. & instructions of engineer incharge. 183 5.3 PCC with existing gravelCollection, screening, cleaning & stacking of existing laid stone ballast (gravel) & laying 100mm thick PCC (1:4:8) using 20mm nominal coarse aggregates & re-laying the collected gravel in 100mm thick layer over the PCC including construction of toe wall (exposed wall plastered with cement mortar 1:5) to hold 40mm size uncrushed/crushed/ broken stone/pebbles wherever required in the bays covered under the present scope as detailed in the GELO & instructions of engineer incharge, only the gravel laid a fresh will be measured and paid. 184 6. RCC Antifire wallDesign Engineering & construction of RCC anti fire wall of suitable height & length between 500 MVA T/F and all associated works including supply of labour, material, cement, reinforcement steel, steel form work etc. as per technical specification. Surplus earth, if any shall be disposed off to a suitable place within the substation as per direction of engineer incharge without any extra cost. 185 7. AC Kiosk (RCC Framed Structure)Design, Engineering (architectural and structural drawings of AC Kiosk room), supply of labour, material and construction of AC Kiosk room on RCC framed structure including Anti-Termite treatment, plinth protection, electrification (Ceiling LED tubes with fitting, modular switches, boxes, AC, electric wire etc.), acrylic emulsion and weather proof (exterior acrylic paint),aluminum work (doors/windows/ventilators frames etc), false ceiling, floor finishing,indoor RCC cable trenches,double brick wall with 50mm thick glass/mineral wool insulation complete in all respect as per technical specification. Items, which are not mentioned but required for completion of work shall be provided by the successful bidder without any extra cost. Surplus earth, if any shall be disposed off to a suitable place within the substation as per direction of engineer incharge without any extra cost.i) 400 kV side 186 ii) 220kV Side 187 Dismantling of existing RCC trenches and Brick drainsDismantling including foundations of following structure. The material whatsoever shall be the property of the successful bidder. The dismantled material shall not be allowed for reuse at any of the sub-stations; however, HVPNL may allow use of bricks for brick ballast purpose only. Further, if rerouting of drain is required in present bays the same shall be is in the scope of successful bidder without any extra cost.8.1 Dismantling of existing RCC trenches and Brick drains
Contract Date : Ref. Documents   |   Contract Value : Ref. Documents
BRR : 7296200 Tender For Construction Of 110 Kv Substation Kothakurussi - Erection Of Yard Structures And Equipments At 110 Kv Substation Kothakurussi-Capital work of 110kV Substation,Kothakurussi -Erection of Yard structures and Equipments at 110kV Substation Kothakurussi.-after dragging up to 50M using suitable lifting device carefully without causing any damage to equipments and fastening in the lorry make it ready for transportation as per the direction of the department officers. 2 Unloading one 110/66KV LA from department lorry to substation site using suitable lifting device and dragging to safe place without causing any damage to CT as per the direction of the department officers. 3 Loading one 110/66KV CT / CVT / PT / CC from the place of its storage to department lorry using required lifting device without causing any damage to equipment and its parts. 4 110KV CT, PT 5 110KV NCT 6 11KV NCT 7 Unloading one 110/66KV CT/PT/CVT/CC from department lorry to substation site using suitable lifting device and dragging to safe place without causing any damage to CT as per the direction of the department officers. 8 110KV CT, PT 9 110KV NCT 10 11KV NCT 11 Loading one set 110/66KV Circuit breaker with its interrupting poles, mechanism box, structures and all its accessories safely without causing any damage using necessary lifting devices to department lorry and fastening for transportation 12 Unloading one set 110/66KV Circuit breaker with its interrupting poles, mechanism box, structures and all its accessories safely without causing any damage using necessary lifting devices from department lorry to substation site and stacking properly for safe storage. 13 Loading one 110/66KV LA from the place of its storage to department lorry, if required, after dragging up to 50M using suitable lifting device carefully without causing any damage to equipments and fastening in the lorry make it ready for transportation as per the direction of the department officers. 14 11KV LA 15 Unloading one 110/66KV LA from department lorry to substation site using suitable lifting device and dragging to safe place without causing any damage to CT as per the direction of the department officers. 16 11KV LA 17 Loading one set 110/66KV Line Isolator with its insulator stacks, supporting channels, connecting pipes, isolating rods, earth switches, mechanism box, structures and all its accessories safely without causing any damage using necessary lifting devices to department lorry and fastening for transportation 18 Unloading one set 110/66KV Line isolator with its insulator stacks, supporting channels, connecting pipes, isolating rods, earthing rods, mechanism box, structures and all its accessories safely without causing any damage using necessary lifting devices from department lorry to substation compound and stacking properly for safe storage. 19 Loading 1x500 sq. mm XLPE cable from its place of storage to department lorry and properly without causing any damage to its insulation and make ready for transporting as per the direction of department officers. 20 Unloading 1x500 sq. mm XLPE cable from department lorry to substation site and stacking properly without causing any damage to its insulationas per the direction of department officers. 21 Loading MS / GI materials hard ware fittings of line work and clamps for equipments and bus from the place of its storage to department lorry and make it ready for transportation as per the direction of departmental officers. 22 Unloading MS / GI materials, hard ware fittings of line work and clamps for equipments and bus from department lorry to substation site and stacking for proper storage as per the direction of departmental officers. 23 Transportingby head load, the materials issued departmentally to the site from the place of storage and distribution to erection site 24 Drilling holes in yard structure 25 Cutting of steel angle in yard structure erection 26 Welding charge for welding on iron parts using arc welding as per standards 27 Fabrication of structures for erecting equipments. The GI & MS angles will be supplied departmentally 28 Erection of yard structures and assembling of columns and beams using bolt and nut including punching of holes. 29 Erection of 1 No. 110/66KV CT/PT/CVT/CC/220KV NCT on the already erected structure of above 1.5m height after opening of crates at the place of storage, leading to site carefully keeping at vertically not allowing tilting from vertical position more than the specified angles, keeping lines and levels as per the direction of the departmental officers, including all labour charges, hire charges of tools& tackles etc. 30 Conveying to the erection site and erecting carefully 1 No. 33KV CT/PT/110KV NCT & RVT/NCT(52/36kV) on the already erected structure after opening of crates at the place of storage leading to site carefully keeping at vertically not allowing tilting from vertical position more than the specified angles, keeping lines and levels as per the direction of the departmental officers, including all labour charges, hire charges of tools& tackles etc. 31 Erection of 1 No. 11KV CT/PT/11KV NCT on the already erected structure after opening of crates at the place of storage leading to site carefully keeping at vertically not allowing tilting from vertical position more than the specified angles, keeping lines and levels as per the direction of the departmental officers. 32 Erection of 1 No. 11KV LA (station type ) /11KV Post insulator on the already erected structure after opening of crates at the place of storage leading to site carefully, keeping lines and levels as per the direction of the departmental officers. 33 Erection of 1 No. 110/66KV LA/Post insulator on the already erected structure after opening of crates at the place of storage leading to site carefully, keeping lines and levels as per the direction of the departmental officers. 34 Erection of one set 110/66KV Bus Isolator on the already erected structure including opening crates and conveyance of all accessories from the place of storage to the place of erection to lines and levels, erection of mechanism box , checking operation and aligning properly, including cutting, welding etc.complete as per the direction of departmental officers. 35 Erection of one set 110/66KV line Isolator on the already erected structure including opening crates and conveyance of all accessories from the place of storage to the place of erection to lines and levels including erection of mechanism box checking operation and aligning properly as per the direction of departmental officers. 36 Unpacking carefully and leading one set of 3 pole EHT110/66KV Circuit Breaker from the place of storage, including support structure , mechanism box compressor, pipe lines etc. to site , cleaning and erecting on foundation using suitable lifting tools, after disassembling necessary parts if required, to lines and levels and assembling all the parts , connecting mechanism etc. in complete shape and making ready for commissioning as per the direction of departmental officers. 37 Uncoiling, paving out, stringing and fixing of bus bar using ACSR Kundah / Moose single conductor for one phase of 66/110KV bus of span up to 30M by cutting the conductor to sufficient length, crimping using compressor / bolting the two ends, washing, cleaning and drying the insulator discs, fixing the conductors to the yard structure with sufficient tension using string of insulators and hardware complete. at both ends, fixing of arcing hornes including transportation of materials from the stockyard to the site under the supervision and direction of department staff at site.(All materials will be supplied departmentally at free of cost). 38 Stringing and fixing earth wire of size 7/9, 7/10 or 7/3.15 between top of the columns and to terminal tower at 33/66/110/220KV substations with compressed / bolted ends at proper tension including uncoiling and cutting of conductor , jumpering, giving earth bond connections by drawing the end of the conductor through the columns, jointing where ever necessary providing back stays at the time of stringing etc. as per the direction of the departmental officers. 39 Providinginterconnection between equipments using ACSR Moose/ Kundah/ wolfSingle conductor at both ends with compressed/ bolted ends including uncoiling and cutting of conductor as per the direction of departmental officers. 40 Providing droppers and connecting to lines / equipments or jumper between two buses without suspension insulators using ACSR Moose/ Kundah/ wolfSingle conductor at both ends with compressed/ bolted ends including uncoiling and cutting of conductor as per the direction of departmental officers. (For one phase) 41 Laying of departmentally supplied GI strip/Copper strip of suitable sizeincluding cleaning and neatly bending of strips ,cutting, removing of metal/earth in the yard and burying earth strip to the required depth re-doing the yard metalling as per the direction of the departmental officers. 42 Welding one end of the bended GI strip of size 50x6mm with the riser of the already laid earth mat, welding 150mm in length, 6mm thick on both sides & end of the strip & other end of the strip with yard structure at 2 points 50mm apart each welding points having 50mm length and 6mm thick on both sides & end of the strip including the charges for connecting the strip with structure using bolted joints as per the directions of the department officers. Charges includes hire charges of DC arc welding set, current charges, cost of low hydrogen content DC arc welding electrodes(No.E7018) cost of anti corrosive paint etc. complete.(Structure earthing) 43 Welding overlapping joints of 50x6mm GI strip with 50mm long, 6mm thick welding on all three sides after doing 2 Nos. bolted joints at the centre as specified after cleaning the surface. Charges includes hire charges of DC arc welding set, current charges, cost of low hydrogen content DC arc welding electrodes( No.E7018) cost of anti corrosive paint etc. complete. 44 Welding one end of the bended GI strip of size 50x6mm with the riser of the already laid earth mat, welding 150mm in length, 6mm thick on both sides & end of the strip and connecting other end with nuts & bolts if required as per the directions of the department officers. Charges includes hire charges of DC arc welding set, current charges, cost of low hydrogen content DC arc welding electrodes(No.E7018) cost of anti corrosive paint etc. complete.(Equipment earthing) 45 Welding one end of the GI strip 50x6mm with the structure with a welding length of 50mm & 6mm thickness on both sides & end of the strip and connecting other end with bolts & nuts if required including hire charges of DC arc welding set, current charges, cost of low hydrogen DC arc welding electrodes (No.E7018) cost of anti corrosive paint etc. complete. 46 Fixing departmentally supplied marshalling kiosk in the existing PT/CT structure by making suitable fixing arrangements including cutting , welding, drilling holes etc as required. 47 Collecting from store or substation wherever available tools and materials such as jacks pulling and lifting machines,rails,sleepers, plies, ropes, empty drums, dummy plates, bolts and nuts gaskets, etc. including loading and unloading in department vehicle and accompanying and returningthe same after completing the work as per the direction of departmental officers.( Only if required) 48 Unloadingthe power transformers of weight 20T to 30T, carefully and safely inch by inch inserting railsand trawling to the platform made with sleepers and thus lowering very carefully inch by inch for placing on the rail track and hoisting to the plinth with out causing damage to transformer and accessories as per the direction of the departmental officer observing all safety precautions. 49 Pulling the power transformers of weight 20T to 30T, on the rail track, travelling for a distance up to 30M, using sleepers, rails, jacking, pulling and keeping ready for placing on the correct plinth as per the direction of departmental officers at site, safely without damaging any equipments and observing all safety precautions. 50 Loading to the department lorry the accessories of 10/12.5MVA transformer such as bushings with proper package, coolers, conservator tank, connecting pipes, bolt and nuts, wheels, rollers, fans, driving mechanism, cooler control box and oil drums etc. safely fastening them properly, accompanying the vehiclewith transformer from ……………….. to ……………and unloading and stacking in convenient place, taking all safety precautions as per the direction of departmental officers. 51 Assembling the 10 /12.5 MVA, 110/11 or 66/11KV transformer with all accessories in complete shape and filling oil if required including arresting the movement of the transformer by locking as per the direction of the departmental officers. 52 Covering the transformer with tarpaulin using ropes, bamboos etc. 53 Giving three phase connection to the filter unit from the supply mains using cable including fitting three numbers of fuse units near the filter unit and laying the cable from control room to filter unit and trial run of filter unit after giving connection etc. complete. ( Only iffound absolutely necessary and where departmental staff is not available ). 54 Hot oil circulation after draining oil from transformer, evacuating the transformer by using vacuum pump after providing LT connection to the pump , connecting the hose to transformer, operating carefully and continuously for attaining sufficient vacuum and keeping in vacuum for 24 hours and operating filter unit carefully and continuously for 24 hours except halt due to poor voltage and trouble in filter plant etc complete as per the direction of dept. officers. 55 Disconnecting the power connections to the filtering plant/ vacuum pump, coiling the cable, disconnect the hoses and coiling them and folding and removing tarpaulin used for covering the transformer, moving the filter plant and vacuum pump to a distant place as directed by the department staff. ( where departmental staff is not available and is found absolutely necessary) 56 Loading the 6000/5000litre/hr.or above transformer oil filter plant tolorry using tripod, chain block, pulley block, rope etc., after pulling it to the convenient position for lifting and fixing it firmly for safe transportation to the location as directed by department officers, unloading the same without causing any damage and placing it carefully at convenient place etc. complete as directed by department officers at site where ever required. 57 Turning and shifting 6000 L/H capacity transformer oil filtering plant or wheel mounted 10000/15000 Litre. oil tank with all accessories for a distance of 20Mto road, towingthe machine with department lorry by the use of D-Shackle and iron ropes , accompanying the lorry including supervision through out the journey especially in turnings to avoid falling of plant. Remove the machine from the lorry and drags up to 10M for safe storage where ever required. 58 Loading the empty oil tank of capacity 10000/15000 Ltr. From the place of its storage using wooden blocks, lever etc. and moving the tank to a distance of 10M from switch yard then loading the same to the dept. vehicle using chain pulley etc. carefully tying the tank in vehicle accompanying the vehicle up to Kothakurussisubstation, removing ties andunloading the tank carefully by the use of wooden blocks rails, chain pulley etc. again moving the tank to a distance of 50M, for safe storage. 59 Loading one vacuum plant of capacity 3HP with its pipelines to department lorry and unloading the same at the required substation as per the direction of departmental officers. 60 Laying 1 x 500 sq mm XLPE cables in trench including drawing through pipes wherever necessary 61 Doing out door/indoor cable termination of 1x500 mm2 11KV XLPE cable very carefully observing directions of manufactures and departmental staff including crimping of socket 62 For mounting 1 x 500 mm2 out door / indoor cable termination 63 Unpacking the transformer / feeder C&R panels, 110V battery charger, OLTC cubicle LT panel at the place of storage transporting to the place of erection and erecting after providing foundation bolt keeping to lines and levels as per the direction of departmental officers. 64 Unpacking at the place of storage and transporting 11KV indoor VCB/SF6 switch gear panel and its accessories to the place of erection and erecting after fixing foundation bolts by chipping concrete wherever necessary, tightening, keeping lines and levels taking all safety precautions including erection of potential transformers as per the direction of departmental officers. 65 Interconnection of panels and 11KV bus bars after opening covers, earthing, inter panel wiring, etc. and making ready for commissioning of breaker as per the direction of the departmental officers. 66 Assembling 55 cells of 100AH conventional battery, pore the acid in required level, connect the battery to the charger and charge to the required specific gravity level, check the specific gravity and voltage of each cells hourly. After attaining the required specific gravity and voltage keep the same for 24 hours, discharge the same up to 50% of the rating and then boost charge the same monitor the voltage and specific gravity regularly and make the battery ready for station use. 67 For 200AH Battery 68 Preparing wiring schedule per transformer / feeder bay of 110 or 66kV with details of type of cable, core and colour, ferrule No. and terminal no of equipments/panelsincluding giving full details in A4 sheet with computer print providing outer border line and sheet no etc. and supplying in the shape of book with special binding etc. and assisting the departmental officers at the time of relay testing and commissioning 69 Master Copy 70 Additional Copy 71 Uncoiling 20/19 core 2.5sqmm, 12 core 4 sqmm control cable (Armoured or un armoured) from cable drums cutting to required length and laying through trench/pipe/cable tray grouping the same neatly using cable tie and carefullyincluding for providing loop wherever necessary and providing cable marker at both ends of cable as per direction of departmental staff at site. 72 Uncoiling 12/7/6 core 2.5 sq mm control cable (armoured and un armoured) from cable drums and cutting to required length and laying through trench/pipe/cable tray grouping the same neatly using cable tie and carefullyincluding for providing loops wherever necessary and cable marker, at both ends of cable as per direction of departmental staff at site. 73 Uncoiling 4/2 core 2.5sqmm control cable (armored or unarmored) from cable drums and cutting to required length and laying through trench/pipe/cable tray neatly and carefully including for providing loops wherever necessaryand cable marker at both ends of cable as per direction of departmental staff at site. 74 Uncoiling 5/4/3/2 core 4sqmm control cable(armoured or un armoured) from cable drums and laying through trench/pipe/cable tray neatly and carefully including for providing loops wherever necessaryand cable marker at both ends of cable as per direction of departmental staff at site. 75 Fixing all type of terminal connecting strip with terminal connectors in the marshalling box or panel boardwherever necessary (terminal connecting strip will be supplied departmentally ) charges includes for providing necessary suitable hole etc complete as per direction of departmental staff at site. 76 Termination of cables in panel by using cable glands of fixing the cable rigidly by any means as per direction of departmental staff at site charges include for providing necessary suitable hole in the gland plate etc. 77 20/19 core 2.5sqmm cable/12 core 4 sqmm cable (using gland of size 28-32mm) 78 12/7/6 core 2.5 sqmm cable (using gland of size 25mm) 79 4/2 core 2.5 sq mm cable/4/2 core 4 sq mm cable (using gland of size 16-22mm) 80 Doing termination of all sizes of PVC insulated copper control cable 2.5mm², pealing, providing number and letter ferrules in the wire, stripping ends, crimping with suitable lugs and connecting to the terminals in the panel board and marshalling kiosk etc., neatly and carefully including cost of copper sockets and ferrules as per the direction of Departmental Officers at site. 81 Doing termination of all sizes of PVC insulated copper control cable 4.0 mm², pealing, providing number and letter ferrules in the wire, stripping ends, crimping with suitable lugs and connecting to the terminals in the panel board and marshalling kiosk etc., using cable tieand cable tie neatly and carefully including cost of copper sockets and ferrules as per the direction of Departmental Officers at site. 82 Supplying aluminium cable tags punching number and alphabets up to 7 digits and binding to cable using copper wire including cost of all materials as per the direction of Board Officials at site. 83 Making of cable clamps using 25x 3 mmGI strip (hot dipped)as per no of cablesin cable tray cutting and holing to required length and for fixing as per the direction of departmental officers at site including supply of suitable nut and bolts. 84 Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m., asdirected by Engineer-in-Charge: All kinds of soil 85 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 86 Supplying and laying tarpaulin sheet of thickness 150GSM of approved make and quality over levelled surface including cost of tarpaulin sheet, wastage overlaps, conveyance and labour charges ect. Complete. 87 Supply and stacking Stone Aggregate (Single size) : 20 mm nominal size 88 Spreading 40mm stone aggregate/20mm stone aggregate in the yard about thickness of 15cm as per the direction of department officers at site 89 Conveying of precast RCC slabs (of various size) manually from stacking place within initial lead etc. complete and laying carefully in position without damaging the edges of slabs as well as cable trench side wall as per directions of Engineer-in- Charge. 90 Loading HT A type pole from the stacking place and unloading the same at work site (transport by vehicle). 91 Transporting poles by hired vehicle to a distance upto 5km and carrying upto 4 poles excluding loading & unloading. 92 Fitting and erecting one HT DP using A type pole in position incl. fitting 2 channel cross arms, digging & back filling pit, drawing earth leads. 93 Drilling hole of various sizes on existing Channel/Cross Arm. 94 Additional rate for excavation of Pit for A type pole in Hard Laterite. 95 Providing one Earth using earth pipe including digging separate pit at standard distance away from the pole/structure & backfilling. 96 Additional rate for excavation of one Earth Pit (2.5m depth) in Hard Laterite 97 Fitting one Additional 3m Channel cross arm (35x35x5mm), in existing 11kV DP incl. conveyance of materials. 98 Erection of one set 11KV Isolator / AB switch (station class)on the already erected structure including opening crates and conveyance of all accessories from the place of storage to the place of erection to lines and levels including erection of mechanism box checking operation and aligning properly as per the direction of departmental officers. 99 Erecting one 250kVA Transformer to existing Plinth/Platform and giving connections,includingloading from TMR/SRS/other stacking place & unloading at site but excluding cost for transporting transformer 100 Providing concrete muffing (0.45x0.45x1.5m) inclusive of cost of all material (as per specification). 101 Loading 3x300 sq. mm XLPE cable from its place of storage to department lorry and properly without causing any damage to its insulation and make ready for transporting as per the direction of department officers. 102 Unloading 3x300 sq. mm XLPE cable from department lorry to substation site and stacking properly without causing any damage to its insulationas per the direction of department officers. 103 Laying 3 x 300 sq mm XLPE cables in trench including drawing through pipes wherever necessary. 104 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11KV gradedirect in ground including excavation, sand cushioning,protective covering and refilling the trench etc as required. 105 Doing out door/indoor cable termination of 3x300 mm233KV XLPE cable very carefully observing directions of manufactures and departmental staff including crimping of socket 106 Mounting one 3x300 mm2 XLPE out door cable termination of structures very carefully without causing any damaged to the drilling holes wherever necessary as directed by the departmental officers 107 Random rubble masonry in CM 1:6 for foundation and basement including cost of all materials, conveyance, labour charges, etc. complete as perspecifications.
Contract Date : 29 Apr, 2025   |   Contract Value : 45.02 Lakhs
BRR : 10591948 tender for WORK OF REPLACEMENT OF EXISTING 100 MVA 220 / 132 KV TRANSFORMER (EMCO MAKE) WITH NEW 160 MVA 220 / 132 KV TRANSFORMER (TAL MAKE) AND OTHER ASSOCIATED WORKS AT 220 K.V. SUB STATION KURSI ROAD UNDER E.T.D. - II, LUCKNOW Sl. No. Item Description 1 Following Works are to be carried out at 220 K.V. Sub Station Kursi Road, Lucknow for replacement of existing 100 MVA 220 / 132 KV Transformer (EMCO make) by new 160 MVA 220 / 132 KV Transformer (TAL make) alongwith associated works against Increasing Capacity including all cost of men, T&P, Crane, 6 - 12 KL / Hr. capacity Centrifuging Machine with Operator, Carriage Vehicle etc. to complete the job satisfactorily as per direction of site Engineer : 2 Draining of Oil from 100 MVA EMCO make Transformer at 220 KV Sub Station Kursi Road into 209 Liter Capacity Oil Drums. 3 Dismantling of existing 120 KV LAs alongwith associated structures instailed in 100 MVA 220/132 KV Transformer Bay after due cutting of earthing, opening of jumpers etc. (1 Job per L.A. with structure). 4 Complete dismantling of all the water & air pipe lines, pipe supports etc. of Emulsifire Systern around the 100 MVA 220/132KV Transformer alongwith Shifting & Stacking of all the dismantled items at safe storage place at the Sub Station. 5 Opening of HV & LV side Jumpers, Removal of Neutral & Main Tank Earthing, Opening of Control / Power Cable Connections of 100 MVA 220/132 KV Transformer including opening of connections of associated OLTC & Marshalling Box. 6 Complete safe Dismantling of the accessories of 100 MVA 220/132 KV Transformer including opening of Jumpers, removal of earthing, opening of Cable connections, Removal of Conservator Tank, Pipe Lines, Bushings, Cooling Fans & Pumps, Marshaling Box, Radiators after Draining of Radiator Oil in empty Drums then fixing of blanking plates on the radiators, pipe lines, conservator tank turret etc. (Suitable Blanking Plate including Bolts & Nuts as required if not available at substation, shall be provided/arranged by the Contractor.) 7 Safe Shifting & proper Stacking at storage place of all the dismantled accessories of 100 MVA 220/132 KV Transformer i.e. Conservator Tank, Pipe Lines, Bushings, Cooling Fans & Pumps, Marshaling Box, Radiators, Headers, A Frame etc. and T/F Oil Drums at the safe storage place at the Sub Station. 8 Proper packing of HV/LV neutral bushings of the dismantled 100 MVA 220/132 KV Transformer in separate wooden cases / crates of the bushings after proper wrapping of bushing with polythene sheet alongwith reparing of wooden cases, to be provided by contractor. 9 (A) Shifting of Main Tank of the dismantled 100 MVA (EMCO make) 220/132 KV Transformer from the Plinth up to 20 Meter distance including turning of Tank, as required. 10 (B) Additional Shifting of the tank of above transformer upto 200 Meter distance. (01 Job for every 5 Meter and / or part there of) 11 Dismantling and shifting of existing 100 MVA TF RTCC panel from ACDB room including opening connection of control cables , identifying cables for future connection & shifting RTCC panel at place of storage as per instructions of supervising engineer (SDO/JE) 12 (A) Shifting of Main Tank of the new 160 MVA (TAL make) 220/132 KV Transformer to its Plinth from Place of Unloading up to 20 Meter distance including turning of Tank, as required. 13 (B) Additional Shifting of the tank of above transformer upto 120 Meter distance. (01 Job for every 5 Meter and / or part there of) 14 Complete erection of the 160 MVA (TAL make) Transformer including its radiators, conservator tank, turrets, connecting pipe lines, HV / HV / neutral bushings, cooling fans, OLTC drive mechanism box, marshalling box, OTI, WTI, capillary tubes etc. 15 Supply of dry Nitrogen gas having DEW point (-60°C to -65°C) under vacuum fro top valve of the transformer upto pressure of 2PSI (as per tehcnical norms of Transformer) and maintaning the same in the main tank for 12 Hrs. including cost of nitrogen gas and nitrogen gas filling device for dry cycle. 16 Create the vacuum inside the T/F tank & maintain it for 24 Hrs. dry air cycle of T/F creating vacuum inside the main tank of T/F, maintaning it for 24 Hrs. then filling of dry air bearing dew point (-60°C to -65°C) for 24 Hrs. And repeating the same till the PPM value of main tank is achieved below 05 PPM filling the oil step by step in 160 MVA T/F. 17 Centrifuging of completed T/F oil in T/F oil tank by connecting centrifuging machine to be provided by the contractor and taking the BDV,PPM & IR values of the oil & TF bushings periodically till the required value in achieved as per direction of Supervising Engineer (Centrifuging machine, BDV & PPM machine, megger shall be arranged by the contractor). After centrifuging ,DGA test of oil sample is to be carried out. 18 Carriage of oil tank of 20KL (01 Nos) capacity from 220 KV S/S Chinhat to 220 KV S/S Kursi Road distance upto 20 KM including loading and unloading at respective place and after work completion. Carriage of oil tanks of 20 KL (01 Nos.) from 220 K.V. Sub Station Kursi Road to 220 KV S/S Chinhat. 19 Delta earthing of 160 MVA Transformer consisting of fabrication of delta set with 03 Nos. 40 mm / 33 mm dia size 03 Mtr. ling electrode, its placing inside ground and connecting all the these electrode with 75x10mm M.S. Flat 700 mm deep and connecting the same with earthmat at two places. Also connecting delta to earth mat of substation at two places as per drawing provided by site engineer from UPPTCL. The work also to be done for painting the welding joint in black colour below earth level and green colour above ground level in two coats. (MS Rods & MS Flat will be provided by the department free of cost). 20 Erection of 132 KV LAs including erection of associated ALP structures, earthing of the LAs with existing M.S. Flat and jumpering with ACSR Zebra Conductors to connect with 132 KV Jack Bus with the help of ACSR Zebra Conductor, associated terminal connectors, P.G. Clamps etc. (01 Job per LA with associated structure). 21 Jumpering of HV side bushing of the 160 MVA transformer to connect with HV side CTs through 220 KV LAs with ACSR Zebra Conductor, associated terminal connectors etc. 22 Jumpering of LV side bushing of the 160 MVA transformer to connect with LV side CTs through 132 KV LAs with ACSR Zebra Conductor, associated terminal connectors, PG Clamps etc. 23 Laying of following size control cables from C&R panel to marshalling box/equipment/ junction box etc in switch yard for new 160 MVA T/F as per cable schedule along with saddling at every 750mm distance with MS saddles of size 25x3 sq mmincluding carriage of cable drums from store to laying site and shifting back remaoning drumsto store after work completion. The work shall also include interconnection of control cables with marshalling box , OLTC panel to RTCC panel, ferruling, dressing of cables and other associated works for satisfactory completion of job as per technical specificatons: 24 2C x 2.5 sq mm 25 4C x 2.5 sq mm 26 6C x 2.5 sq mm 27 10C x 2.5 sq mm 28 Erection of new 160 MVA TF RTCC panel including shifting from place of storage to ACDB room as per directions of site engineer (SDO/JE). 29 Earthing of main tank, marshalling box, drive mechanism, Transformer neutral, , RTCC panel etc of new 160 MVA Transformer with 50 x 6 mm and 75 x 10 mm size MS flats, its jointing with already existing earth mats/ deltas including necessary modification in existing support for earthing of neutral bushing for its earthing work and then painting of earthing strips as per technical specifications. 30 Making termination / connection of the control & power cables as per new cable schedule of 160 MVA Transformer, RTCC Panel, control & relay panel, cooling fans, pumps, marshalling box. OLTC, driving mechanism etc. dressing & binding of additional control cables, if required as per site requirement alongwith making necessary holes in the gland plate / box, wherever required including providing & fixing of cable glands of appropriate sizes providing of ferrules etc. 31 Testing of new 160 MVA Transformer 32 Conducting test of 160 MVA T/F (M/s TAL make) by arranging appropriate equipments for following items :-i. DGA test of Transformer oil & Water Content Test of Transformer oil 33 Conductioning test of 160 MVA T/F (M/s TAL make) by arranging appropriate equipments for following items :-1. WRM-01 No.2. Tan Delta-02 No. (Pre-erection and post-erection)3. Turret CT Ratio. Polarity, Knee Point continuity & I.R. Test 34 Work of re-erection, hydraulic testing, & commissioning of water spraying and fire detection mulsifyre system comprising of following detailed pipe lines with all cost of men, material, T&P etc required for the job as per details below: 35 Supply and installation of 80 mm dia B-class GI pipe for support with round clamp at top & flanges at bottom as per specifications including grouting and painting etc. 36 Providing, laying, installation , testing and commissioning of new 50 mm dia B class GI pipe with elbows, Tees, sockets, flanges, bends etc including its painting and connection to already dismantled existing pipe lines ( as may be required) 37 Providing, laying, installation , testing and commissioning of new 40 mm dia B class GI pipe with elbows, Tees, sockets, flanges, bends etc including its painting and connection to already dismantled existing pipe lines ( as may be required) 38 Providing, laying, installation , testing and commissioning of new 25 mm dia B class GI pipe with elbows, Tees, sockets, flanges, bends etc including its painting and connection to already dismantled existing pipe lines ( as may be required) 39 Supply, installation of HV nozzle projector HD make. 40 Supply, installation , testing of QB detector 41 Laying, installation, testing & commissioning of old G.I. Pipe B Class including cutting, welding etc. and providing suitable Flangs alongwith necessary fitting viz bends, elbow, tees, reducer, gasket etc.:- 42 25 mm dia. G.I. Pipe 43 50 mm dia. G.I. Pipe 44 65 mm dia. G.I. Pipe 45 80 mm dia. G.I. Pipe 46 100 mm dia. G.I. Pipe 47 150 mm dia. G.I. Pipe 48 Installation of HV nozzle projector 49 Installation of HV HD Fire detector 50 Erection, hydraulic testing & commissioning of complete mulsifyre system by installation of high velocity water spraying & fire detection system on 160 MVA 220/132KV TF by using old dismantled/newly laid additional pipe lines including providing of new gaskets/packings of required sizes along with necessary welding / jointing and earthing of pipe supports after re-construction of damaged RCC foundation for pipr supports. 51 Painting of above installed water spraying & fire detection system on 160 MVA 220/132KV TF in 02 coats of synthetic enamel paint after due application of 01 coat of red oxide primer after removal of old paint by rubbing with emery paper. The water pipe lines shall be painted in P.O. red color , Air pipe lines in sky blue color,Pipe supports in black color, earthing strips in Bus green color. 52 Electrical Safety processing fees needed for providing all relvant safety clearance documents from electrical safety department for energisation of the above commissioned 160 MVA Transformer and its accessories (Note: The amount payable is actual rate of challan or quoted rate, whichever is lower) 53 160 MVA Power Transformer 54 All LA (220/132 KV) associated with newly commissioned 160 MVA Transformer 55 HT inspection fees 56 Work of re-erection, hydraulic testing, & commissioning of water spraying and fire detection mulsifyre system on 132/33 KV 63 MVA M/s Atlanta make Transformer, comprising of following detailed pipe lines with all cost of men, material, T&P etc required for the job as per details below: 57 Providing, laying, installation , testing and commissioning of new 150 mm dia B class GI pipe with elbows, Tees, sockets, flanges, bends etc including its painting and connection to already dismantled existing pipe lines ( as may be required) 58 Supply and installation of 80 mm dia B-class GI pipe for support with round clamp at top & flanges at bottom as per specifications including grouting and painting etc. 59 Providing, laying, installation , testing and commissioning of new 40 mm dia B class GI pipe with elbows, Tees, sockets, flanges, bends etc including its painting and connection to already dismantled existing pipe lines ( as may be required) 60 Providing, laying, installation , testing and commissioning of new 25 mm dia B class GI pipe with elbows, Tees, sockets, flanges, bends etc including its painting and connection to already dismantled existing pipe lines ( as may be required) 61 Supply, installation of HV nozzle projector HD make. 62 Supply, installation , testing of QB fire detector 63 Replacement of diaphragm along with re-installation of quick opening flood, deluge valve HD make 150NB as per maximum working pressure 10kg/sq mtr of deluge valve system. 64 Erection, hydraulic testing & commissioning of complete mulsifyre system by installation of high velocity water spraying & fire detection system on 63 MVA 132/33 KV TF by using old dismantled/newly laid additional pipe lines including providing of new gaskets/packings of required sizes along with necessary welding / jointing and earthing of pipe supports after re-construction of damaged RCC foundation for pipe supports. 65 Painting of above installed water spraying & fire detection system on 63 MVA 132/33 KV TF in 02 coats of synthetic enamel paint after due application of 01 coat of red oxide primer after removal of old paint by rubbing with emery paper. The water pipe lines shall be painted in P.O. red color , Air pipe lines in sky blue color,Pipe supports in black color, earthing strips in Bus green color. 66 Following works including Providing of materials are to be carried out at 220 KV S/S Kursi Road Lucknow for Proper Lighting arrangement along the 160 MVA Transformer bay and other crucial places in switchyard with all cost of men, materials ,T&P etc . Except Cables Which shall be Provided by the Department as per direction of Supervising Engineer . 67 Providing of Lighting Junction Box of size of 280 mm x 150 mm made of 16 SWG M.S. B.P. Sheet & Painted with smoke Grey colour synthetic enamel Paint, duly fitted with 1 No 6 Amp. S.P. M.C.B. on Anodised M.S. Channel ,1 No Bakelite Fuse Fitting with 6 Amp. ,Capacity NS 6 type HRC Fuse,01 No . Copper Neutral Link ,Bakelite terminal strip of 4 Nos. terminals,Cable Glands suitable for 2C /4C x 2.5 Sq. mm size incoming /outgoingControl cable etc.& fixing on the GI Structure at designated height with the help of suitable duly fabricated M.S. Bracket Clamps and Due earthung of the Junction Box including Cable Terminations. 68 Providing & Fixing of G.I. S.L. Pole Bracket duly made of 40 mm dia B class 1.20 Meter long M.S. Pipe of (ID 35 mm& OD 40 mm) and bent at one end by quarter circle in 1.0 mtr. At an angle of 30 deg for fixing of 150 watt LED street Light Luminaries Fittings with the help of MS Bracket Clamps of suitable size for fixing on G.I. column structure at designated place. 69 Provinding & Fixing of 150 Watt LED Street Light Luminaries Fittings of PHILIPS/ CROMPTON / HAVELLS/ BAJAJ Make in Single Piece die cast aliminium Alloy Housing with Pot Optics Reflector & Toughed Clear Glass Cover with Frame for Lamp Compartment including Cable Termination . 70 Cable laying & Termination- 71 Laying of following size PVC insulated Copper Control cable from LT ACDB Cubical to Various Junction Boxes below ground level in PVC Conduit pipe (Provided by the contractor ) after due excavation ,back filling etc. including all labour ,PVC Pipe etc. required for proper completion of the work . 72 2 C x 2.5 Sq mm 73 Laying of Control cables between LT Lightinig Junction box & LED Street Light Fittings along GI Structure including necessary clamping with suitable M.S. street clamp with Proper Dressing . 74 Providing & fixing of Post Lamp Glow Light of latest design complete with white color defuser suitable for installation at main entrance/garden/lawn lighting. 75 Fabrication of protective net for radiators of 132/33 KV Transformers, control room glass window, JE room glass window and associated works: 76 Providing, fabrication and fixing of protection net in front of radiator of Trasformer, made of MS channel, angle, mesh and cross section type net. Size of protection net , including all cost of men and material- 77 132/33 KV 100 MVA Transformer M/s Atlanta make, size 2500x5000 sq mm for radiator and 6100x2500 sq mm for marshalling box (total area 27.75 sq mtr) 78 132/33 KV 63 MVA Transformer M/s Atlanta make, size 6000x2500 sq mtr for radiator 79 JE Room glass window 80 Control room glass window 81 Providing, fabrication and grouting of MS Channelin front of radiator by concreting for support of protection net by welding or nut & bolt as required , including all cost of men and material: 82 132/33 KV 100 MVA Transformer M/s Atlanta make, 4500 mm size at 4 places ( Total length 18 mtr ) 83 132/33 KV 63 MVA Transformer M/s Atlanta make, 4500 mm size at 2 places ( Total length 9 mtr) 84 JE Room glass window, 3000 mm size at 2 places ( total length 6 mtr) 85 Control room glass window , 3000 mm size at 4 places ( Total length 12 mtr) 86 Fabrication and fixing of 03 no. P.I. on the top of front protection for extra support of LV side conductor including all cost of men & material: 87 132/33 KV 100 MVA Transformer M/s Atlanta make 88 132/33 KV 63 MVA Transformer M/s Atlanta make 89 Spray/ brush Painting of following equipments/items painting includes one coat of red oxide and two coats of Green/Red colour good quality Asian/Burger/Nerolac make paint after through rubbing and cleaning of old scale of painted surface to remove rust,dust etc. 90 Earthing strip 75 x 10 mm in green Colour 91 Earthing strip 50 x 06 mm in green Colour 92 Switchyard lighting JB in smoke grey color 93 220KV CT/CVT in smoke grey color 94 220KV SF6 CB in smoke grey color 95 220KV & 132KV Isolator operating box in smoke grey color 96 132KV CT/CVT in smoke grey color 97 33 KV Isolator Operating Box in smoke grey colour. 98 33 KV CT & PT Junction Box in smoke grey colour. 99 Work and supply related to work of installation of CCTV camera at crucial places of substation for protection from theft and surveillance of store and switchyard equipment 100 Providing and fixing of outdoor Static (Bullet)IP 2MPCCTV Network camera having resolution 1920x1080,full HD 1080p video, 140 dB, WDR ,3d DNR smart heater ,Image sensor 1/2.8, progressive Scan CMOS,Shutter time 1/100000 Sec. Day and Night IR cut filter with auto Switch weather proof IP 67 protection,IR range 100-120 Meter Model No DS-2CD4A25FWDIZ(H)(S) of Hikvision make or equivalent model of BOSCH/CAME make. 101 Providing and fixing of Full HDoutdoor Dome IP 2MPCCTV camera having resolution 1920x1080,full HD 1080p video, digital WDR ,3d DNR smart heater ,Image sensor 1/2.8, progressive Scan CMOS,Day and Night IR cut filter with auto Switch weather proof IP 67 protection,IR range 50-70 Meter Model No DS-2CD432F-I(Z)(H)(S) of Hikvision make or equivalent model of BOSCH/CAME make. 102 Providing and fixing of 16 Channel Embedded plug and play NVR having 16 channel,2TB HD, SupportH.264+& h.264, 6 MP ,Integrated 16 Port PoE, HDMI, resolution 1920x1080p upto 2 SATA Interface, Model No7614NI-E2/16P of Hikvision make or equivalent model of BOSCH/CAME make. 103 Providing and Fixing of 32 Full HD LED TV (model No KDL-32W700B 80cm) of Sony make 104 Supply and fixxing of 3KVA on -Line UPS with isolation transformersuitable for single phaseAC power supply and single phase outputAC ,floor mounted type with 120 minut power backup APC make (modal No.SURTD3000XLI) or equivalent modelof standerd make. 105 Providing & fixing of 4TB Hard Disk of seagate make for storing the servilance data. 106 Providing & fixing of power supply board 24 Volt DC/24Amp AC of standard make. 107 Porviding & fixing of Power Over Eathernet (POE) Switch (08 Port), 10/1000 MBPS of D-Link make model No. DGS-1210-10P (08 Port) 10/100/1000 MBPS 108 Providing & laying 40 mm dia size HDPE pipe of standard make for laying of power supply cable/OFC/CAT-6 Data cable as per requirement. 109 Providing & laying of RG-60 3 GHZ Co-axial optical fiber cable of Fonolex/Standard make for CCTV wiring. 110 Providing & laying of Cat-6 Data Cable of D-link make for connecting PTZ Cameras to NVR. 111 Providing & laying of 3 Core 1.5 Sq. mm Multi Strnad Copper Wire Power Cable of Finolex/Standard make as per IS alongwith providing & fixing of Junction Boxes whereever required. 112 Providing of Computer Table of Godrej make as per sample. 113 Earthing of Cameras & NVR as per technical specification (01 Job each) 114 Work related to supply & installation of Fire Detection System operating on the basis of feedback by Smoke Detectors in BCUs, Store, ACDB room, Battery room, & office building at 220 KV substation Kursi Road Lucknow 115 Supply & installation of 08-12 Zone Conventional fire detection and fire alarm system with power supply arrangement. (Make compatible with IS: 2189:1999 tested by ERTL (N) and System Sensor (Agni suraksha/ Agni devices/ daksh OR equivalent). 116 Supply & installation of Manual Call Point A breakable glass cover fixed in such a way that the actuating push button is kept depressed as long as the glass is intact and released when the glass is broken. A small steel hammer shall be attached to the assembly with a steel chain to facilitate breaking of glass. The manual call points shall be suitable for surface or fully / partly recessed mounting. 5mm high red painting/printed word IN CASE OF FIRE BREAK GLASS shall be provided on the front face. The manual call point shall be compatible with all conventional control panels. (Make Agni Suraksha (ASES) / Safeway Equivalent Agni Devices). 117 Electronic hooter 11 dB/24V DC with strobe (ABS-V) The enclosure should be 1.5 mm thickness duly painted and marked FIRE ALARM. All hooters shall produce a similar sound and shall maintain the same during their operation. (Make Agni Suraksha (ASES) / Safeway Equivalent/ Agni Devices). 118 Providing & Fixing of lonisation type Smoke Detectors The detector while sensitive to all type of smokes will be insensitive to ambient lights, air drafts, and changes within the operating temperature and voltage ranges. The Detector shall meet the requirements of either EN 54/ FM/ UL or LPC and shall be specifically approved by FM/ UL/LPCB. Apollo / System Sensor /Edward/Bosch. 119 Providing & Fixing of Heat Detectors (for the area like Battery room, AC plant area, DG room, etc) It is a combination of rate of rise and fixed temperature principle using thermistor and with automatic compensation for changes of ambient conditions. The thermal detectors are tested and approved to EN54 part 5 (2000) Class A1R Apollo / System Sensor / Edward / Bosch/Agni suraksha. 120 Providing & Fixing of Response Indicator Lamp assembly consisting of lamp holder and lamp shall be suitable for mounting on walls, partition etc. The housing shall be suitable for surface/flush mounting of 1.5mm thick sheet steel and the facia 3mm acrylic mounted outside a cabin, and directly connected to the detector inside the cabin. In normal circumstances the lamp should flicker but in the event the detector inside the cabin senses a fire, the lamp should glow. 121 Supply and laying 2x1.5sqmm PVC insulated and sheathed stranded copper wire. Wiring for fire alarm system in general shall comply with IS: 2189 and IS: 732 amended up to date. The detectors shall be wired by ISI marked 1.5 sq mm PVC insulated stranded FRLS copper conductor wires of 1100 volts grade as required and desired on site. Crimping type of lugs are also included in the rates of laying wires and its connections.PVC insulated copper conductor wires shall confirm to IS: 694. And, PVC insulated copper conductor armoured cables should confirm to IS: 1554 (part-1). Make National/Plaza/Kalinga or any other standard make 122 Supply and laying 4x1.5sqmm PVC insulated and sheathed stranded copper wire. Wiring for fire alarm system in general shall comply with IS: 2189 and IS: 732 amended up to date. The detectors shall be wired by ISI marked 1.5 sq mm PVC insulated stranded FRLS copper conductor wires of 1100 volts grade as required and desired on site. Crimping type of lugs are also included in the rates of laying wires and its connections. Make National/Plaza/Kalinga or any other standard make 123 Supply and installation of SMF Batteries with suitable rating as required for 24 Hours backup from Exide / Standard / Amco Prestolite/any other standard make. 124 Signage with backlit facility for Control building marking for various Fire / emergency exit points. 125 Supply and laying of Ms/PVC conduit pipe 25mm as per Requirement of site. 126 Provising, fixing & installation of different types of boards i.e. Glow Sign Board, Shutdown Notice Board, Instruction Board etc as detailed bwlow, to be carried out at 220KV substation Kursi Road Lucknow as per specifications and directions of supervising engineer: 127 Providing, fixing and installation of Glow Sign Board of size 10 ft x 6 ft for substation single line diagram to be fixed in control room building of the substtaion. The Glow Sign Board should be illuminated using sufficient number of LED tube lights. The board shall be made of ACrilic sheet and shall be provided with back support frame & fixing arrangement. 128 Name plates made of 2mm thick Aluminium Sheet coveredwith 3 M HIP retro reflective sheet of following size with details / name written by 3M HIP Retro reflective sheet as per prescribed color scheme to be fixed with the help of nuts & bolts at already installed equipment structure in switchyardwith all cost of plates, nut-bolts, misc materials, T&Pand labour as per specificatins & directions of supervising engineer: 129 300mm x200mm 130 450mm x 250mm 131 500mm x 250mm 132 R,Y,B phase plate sets consisting of one plate of red,, yellow, blue colors in each set & plates of dia 250mm duly made of 2mm thick aluminium sheet with face to be fully covered in red , yellow, blue phase colors in 3 M HIP retro reflective sheetand the phase plate set to be fixed with the help of suitable size G.I. bolts, nuts on already installed equipment structure etc at the substation.
Contract Date : Ref. Documents   |   Contract Value : Ref. Documents
Disclaimer

We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.

Tender Detail
Website https://tender.nprocure.com/
Quantity
MSME Exemption No
Tender Type Open Tender
Startup Exemption Click Here
Competitive Bidding NCB
Similar Tenders
TENDER INSIGHTS

858

Electric Tenders
Live
CLICK TO KNOW MAXIMUM WIN

Tell us about your Product / Services,

We will Find Tenders for you

🇮🇳 +91
TenderDetail
Loading tenders