Tender Summary / Eligibility Criteria
PROVIDING E AND M WORK SERVICES AT HAF HINDAN GHAZIABAD SH PROVIDING TECHNICAL STAFF OF VARIOUS CAPACITY DG SET INSTALLED AT TECHNICAL AREA AT HINDAN AIR FORCE STATION GHAZIABAD
Documents
Download All
No Boq
No Corrigendum
Probable Bidders
AI engine predicts probable bidders to help you bid strategically.
MSME Exception
Technical
Tender involves procurement of high capacity electrical equipment including diaphragm coupling of pump &
motor with 90kW capacity at 2900 RPM. The project scope includes installation, testing, commissioning and
operational handover.
Previous / Similar Result
BRR : 11055259
Tender Document For Sub-Station and Transmission Line [PACKAGE-C8(1B)]-TECHNICALSPECIFICATION FOR 12kV, 800A, 18.4kA, MULTI PANEL (Incoming, Bus Coupler with Adaptor Panel and Outgoing) SHUNT TRIP, INDOOR TYPE SCADA COMPATIBLE SWITCHGEAR WITH MOTOR OPERATED SPRING CLOSING VACUUM CIRCUIT BREAKER- 1 ELECTRICAL PART : 2 WBSETCL Assessed Quantities: 3 245KV 40KA for 3sec Gas Insulated Switchgear - i)2500 A rated Double Bus Barwith BUS earthing arrangement ii) 3 phase / single phase encapsulated iii) Minimum 2000 A rated Circuit Breaker for line and Transformers & 2500A for Bus coupler Bay iv) CT with current ratio 1600-800-400/1A (5 core) for feeder & transformer & 2000-1600/1A (3 core) for bus coupler as per CT specification v) Each feeder comprises of Circuit Breaker, Disconnectors, CTs, Bus bar, density monitors, gas partition etc. vi) suitable for EHV cable entry withdouble terminationarrangementif single Run cable is used other will be kept as spare. vii) Standalone Local Control Cubicle (LCC) with all required accessoriesand Gas monitoring system and the requiredPD sensors to cover the total GIS portion. -The complete system shall be as per technical specification and requirement comprising of - 4 Complete LineBayswith accommodation of3 nos GIS Line VTeach having 3 cores(2 nos core for Protection and 1 no core for metering and other parameters as per technical specification 5 LA for Line bay ( one number per phase - to be installed within GIS) 6 CompleteTransformer Bays 7 Buscoupler Bay 8 2 sets of 3 phase Bus PT each having 3 cores (2 core Protection and 1 core Metering), each for Main Bus-I & Main Bus-II with disconnectors & earth switch. As per Tech Spec 9 Disconnector with earthing arrangement and gas tight barriers atOne side of Main Bus I & IIfor future extension.one side 10 Portable UHF PD monitoring System - The analyser shall have 6 channel input withinherent PD location accuracy of 0.5m., colour display unit and user friendly interface for detailed analysis.The system includes allaccessoriesto monitorPD, UHF cables,required software and other accessories to complete as per Technical Specification. 11 Dew Point Meter as per Technical Specification 12 145KV 31.5KA for 3sec Gas Insulated Switchgear i)2000 A rated Double Bus Barwith BUS earthing arrangement ii) 3 phase / single phase encapsulated iii) Minimum 2000 A rated Circuit Breaker iv) Each feeder comprises of Circuit Breaker, Disconnectors, CTs, Bus bar, density monitors, gas partition etc.v) CT with current ratio 1000-800-400/1A (5 core) for feeder & transformer & 2000-1600/1A (3 core) for bus coupler as per CT specification vi) suitable for EHV cable entry withdouble terminationarrangementif single Run cable is used other will be kept as spare. vii) Standalone Local Control Cubicle (LCC) with all required accessoriesand Gas monitoring system and the requiredPD sensors to cover the total GIS portion. -The complete system shall be as per technical specification and requirement comprising of - 13 Complete LineBayswith accommodation of3 nos GIS Line VTeach having 3 cores(2 nos core for Protection and 1 no core for metering and other parameters as per technical specification 14 Complete Transformer Bays for LV side of 160 MVA 220/132 KV Transformer & HV side of 50 MVA 132/33 KV Transformers 15 Bus coupler Bay 16 Disconnector with earthing arrangement and gas tight barriers atOne side of Main Bus I & IIfor future extension.one side 17 2 sets of 3 phase Bus PT each having 3 cores (2 core Protection and 1 core Metering), each for Main Bus-I & Main Bus-II with disconnectors & earth switch. As per Tech Spec 18 36 KV, 31.5KA for 3sec Indoor, floor mounted drawoutSwitchgear Assembly (2500A Bus rating with Copper Bus Bar) with VCB suitable for EHV cable entry withtripple termination arrangement and bus earthing arrangement from both side, Line earthing arrangement and dead line status and corresponding electrical and mechanicalinterlocking arrangementas per technical specification and requirement comprising of - 19 Outgoing Feeder Bays, 1250A Circuit Breaker ratingas per Techspec. 20 LV side of50MVA 132/33KV Transformer Bays (2000 A Breaker Capacity) CT Ratio 2000-1000/1A 3 coreas per Tech spec 21 HV side of6.3 MVA 33/11KV Transformer Bays(1250 A Breaker Capacity ) as per Tech Spec 22 Station service transformer bay (1250A Circuit Breaker rating) 23 Bus section Bay (2500 A Breaker Capacity) 24 (i)2(two) set of 3 phase Bus PT - 5 limb, (One set each for Main Bus-I & Main Bus-II) with isolation arrangement.as per Tech Spec. (ii) Other required equipment & accessories like Bus Earthing arrangement etc. to complete the system . 25 12 KV, 1600 A, 25 KA, 30 V DC, SCADA compatible, VCB Switchgear includingProtection Relays, ,control & annunciation equipment and other accessories complete as per technical specification (uploaded for Nandanpuronly) Cable and bus earthing shall be electrically and mechanically interlocked with associated breaker as per interlock requirement. but rating should be as per BOQrequirement comprising of - 26 Outgoing Line Bays (CT Ratio 400-200/1) 2 coreVCB rating 1250A 27 Incoming Transformer Bays(CT Ratio 600-400/1A) 4 core VCB rating 1250A 28 Bus section Bay VCB rating 1600A 29 (i) 3(Three) set of 3 phase Bus PTwith isolation arrangement must be mounted above incomer switchgearpanel. (ii) Other required equipment and accessories like Bus earthing arrangement etc to complete the system 30 Electric Overhead Travelling Crane (E.O.T.) 31 Electric Overhead Travelling Crane (E.O.T.)- For 220 KV GIS Building 5.0 Metric Ton capacity or maximum weight of GIS shipping unit whichever is higher -complete with all accessories as per technical specification and requirement. 32 Transformers : 33 160 MVA, 220/132/33 KV, 3 Phase ,Auto Transformer suitablefor NIFPSwith Bushing CTs and NCTS andRTCC panel alonwith BCUand other accessories as per technical specification ofAuto Transformer. 220KV & 132KV bushingshall be of RIP/RIS type. 34 Nitrogen injection type Fire Prevention and ExtinguishingSystem including reservoir tank andall required accessories for 160 MVA, 220/132/33 KV, 3 Phase Power Transformer 35 50 MVA, 132/33 KV, 3 Phase, 2 winding Power Transformerwith Bushing CTs and NCTsincluding RTCC panel alongwith BCU and alongwith all accessoriesin line with technical specification of Power Transformer.132 KVbushingshall be of RIP/RIS type. 36 6.3 MVA, 33/11 KV, 3 Phase, 2 winding Power Transformer with Bushing CTs and NCTs in line with technical specification of Power Transformer . As per Tech spec 37 STATION SERVICE TRANSFORMER: 315 KVA, 33/0.415 KV, 3Ph, 2-Windingas per technical specification andrequirement 38 EARTHINGTRANSFORMER: 33KV, 3 Ph ,fault current rating of874 Amp for 30 secas per Technical Specification and requirement 39 Isolators : As per Technical specification 40 220 KV, 1600A, 40 KA for 3sec, HCB, motor operated 3-phase Assembly WITHOUT EARTHING SWITCH (excluding insulators) for HV side of 160 MVA Transformers(water proof mechanism housing with auxiliary switch) 41 Solid Core Insulator for each set of above Isolators 42 220 KV, 1600A, 40 KA for 3sec, HCB, motor operated 3-phase Assembly WITH EARTHING SWITCH (excluding insulators) for Line bay(water proof mechanism housing with auxiliary switch) 43 Solid Core Insulator for each set of above Isolators 44 132KV, 1250 A,31.5 KA for 3sec, HCB, 3Ph Assembly isolator with Earth Switch for line feeder, motor control - excluding solid core insulators as per Tech. Specification (water proof mechanism housing with auxiliary switch) 45 Solid coreInsulator for each set of above Isolators 46 132KV, 1250A,31.5 KA for 3sec, HCB, 3Ph Assembly isolator with out Earth Switch for Transformers, motor control - excluding solid core insulators as per Tech. Specification (water proof mechanism housing with auxiliary switch) 47 Solid coreInsulator for each set of above Isolators 48 33KV, 1250A,31.5 KA for 3sec, CRDB, 3Ph Assemblywithout earthswitch as per Tech. Specification - forHV side of 33/11KV Transformer & Earthing Transformer(excludingInsulators ) 49 Solid coreInsulator for each set of above Isolators 50 33KV, 2000 A,31.5 KA for 3sec, CRDB, 3Ph Assemblywithout earthswitch as per Tech. Specification - for LV side of 132/33 KV Transformer,(excludingInsulators ) 51 Solid coreInsulator for each set of above Isolators 52 33KV, 1250A,31.5 KA for 3sec, CRDB, 3Ph Assembly with Horn-gap fuse units to be mounted on same structure of isolator ( for Station service Transformers ) as per Tech. Specification(excluding insulator) 53 Solid Core Insulator for each set of above Isolators 54 LIGHTNINGARRESTORAs per Technical specification 55 198 KV, single phase, 10 KA, Heavy Duty, Station Class, Gapless (for 2 nos. 160 MVA Transformersas per technical specification and as per requirement. (Polymer type) 56 198 KV class polymer type LA at Composite Tower 57 120 KV, Single phase, 10 KA, Heavy Duty, Station Class, Gapless for 2 nos 160MVA Transformers,2 nos 50MVA Transformerand line bays (Polymer type) 58 42 KV, Single phase, 10 KA, Heavy Duty, Station Class, Gapless (for 2 nos 50MVA transformer, 3 Nos 6.3 MVA 33/11 KV Transformer &2 nos.315KVA station serviceTransformer) ((Polymer type) 59 12 KV, 3 phase 10KA,Station class GapelessLA (LV side of 3nos. 6.3MVA Transformers) (Polymer type) 60 220 V Battery & Charger( As per technical Specification ) 61 VRLA Battery SET - 800AH 220 Voltas per Tech Spec. 62 Battery Health monitoring system forabovementioned 220V batteries as per Technical Specification. 63 Battery Charger - 220Volt. suitable for above Battery set in line with Technical Specification(Float Charger capacity - 80A and Float cum Boost Charger capacity - 150A) - Charger shall be equipped with disconnecting arrangement forLoad and Battery - Charger shall be capable of charging the battery both in Constant Current and Constant Voltage mode with appropriate selector switch - Fuse fail indication arrangements are to be provided for all fuse units. All the indications like fuse fail, blocking diode fail, rect. fail, battery earth fault, charger fail etc are to be provided locally, as well as necessary potential free contacts to send at remote end also. 64 VRLA BATTERY SET -75 AH 30 VoltCapacity will be as per design or75 AH whichever is higher as per uploadedtech spec 65 Battery Charger - 30Volt. Foalt cum Boost Charger Float charger capacity 35A or as per design whichever is higher as per Tech Spec ( uploaded) - Charger shall be equipped with disconnecting arrangement forLoad and Battery - Charger shall be capable of charging the battery both in Constant Current and Constant Voltage mode with appropriate selector switch - Fuse fail indication arrangements are to be provided for all fuse units. All the indications like fuse fail, blocking diode fail, rect. fail, battery earth fault, charger fail etc are to be provided locally, as well as necessary potential free contacts to send at remote end also.(as per uploaded spec.) as per uploaded spec 66 PROTECTION PANEL ( SIMPLEX REAR Open Door type ) inclusive of all relays, Annunciator (Minimum 24 windows or more as per scheme requirement, with RS485 port for Modbus Communication, Auxiliary AC and DC Supply as well as Dedicated AC Fail and DC Fail windows) at each panel and other accessories as per specificaction and requirement. (Protection Panels will be installed in Relay Room.) 67 Protection panel with BCU and Breaker Control Switch for 220 KV Line Feeder. Each feeder panel will have 2 nos. Distance Protection Relays of different manufacturer having different model, algorithm, hardware with Group Selection Switch and all other accessories complete as per Tech. Spec. 68 Protection Panel with BCU and Breaker Control Switch for 220 KV side of 220/132/33 KV Transformer complete as per Tech. Spec. (Transformer Differential Relay, Circulating Curent Protection Relay in addition to all other Transformer HV Protection relays are to be considered in HV side Panel). 69 Protection Panel with BCU (having 2 set voltage coils for measuring 3-phase bus voltages from both Bus PTs) and Breaker Control Switch for 220 KV Bus Coupler complete as per Tech. Spec. 70 220 KV Busbar Differential Panel with low impedance type Centralized Busbar Protection Relay having in-built LBB protection, End Fault protection, CT Open detection feature etc. complete as per Tech. Spec. (Panel to be complete with all relays, components and wiring i.r.o. at least 3 nos. future Line bays and 1 no. future Transformer HV bay in addition to present bays) 71 Protection panel with BCU and Breaker Control Switch for 132 KV Line Feeder. Each feeder panel will have 2 nos. Distance Protection Relays of different manufacturer having different model, algorithm, hardware with Group Selection Switch and all other accessories complete as per Tech. Spec. 72 Protection Panel with BCU and Breaker Control Switch for 132 KV side of 220/132/33 KV Transformer complete as per Tech. Spec. 73 Protection Panel with BCU and Breaker Control Switch for 132 KV side of 132/33 KV Transformer complete as per Tech. Spec. (Transformer Differential Relay, HV REF Protection Relay in addition to other Transformer HV Protection relays are to be considered in HV side Panel) 74 Protection Panel with BCU (having 2 set voltage coils for measuring 3-phase bus voltages from both Bus PTs) and Breaker Control Switch for 132 KV Bus Coupler complete as per Tech. Spec. 75 132 KV Busbar Differential Panel with low impedance type Centralized Busbar Protection Relay having in-built LBB protection, End Fault protection, CT Open Detection feature etc. complete as per Tech. Spec. (Panel to be complete with all relays, components and wiring i.r.o. at least 3 nos. future Line bays and 1 no. future Transformer HV bay in addition to present bays) 76 Protection Panel with BCU and Breaker Control Switch for 33 KV Line Feeder as per Tech. Spec. 77 Protection Panel with BCU and Breaker Control Switch for 33 KV side of 33/0.415 KV Station Service Transformer (S.S.T.) as per Tech. Spec. Panel schematics will be similar to Line Feeder Panel, along with addtitional S.S.T. Supervision Relays. 78 Protection Panel with BCU and Breaker Control Switch for 33 KV side of 132/33 KV Transformer as per Tech. Spec. 79 Protection Panel with BCU and Breaker Control Switch for 33 KV side of 33/11 KV Transformer (considering HV REF Protection Relay, HV Over-current Relay and all other accessories alongwith space and provision for future Transformer Differential Relay) as per Tech. Spec. and actual requirement. 80 Protection Panel with BCU (having 2 set voltage coils for measuring 3-phase bus voltages from both side Bus PTs) and Breaker Control Switch for 33 KV Bus Section bay as per Tech. Spec. 81 Meter Panel without meter( As per drawing uploaded) 82 XLPE Copper Cableas per Technical Specification 83 220 KV 630 Sq. mm single Core Copper Cable AL sheath forLine from Composite Tower To GIS- Single phase connection with double run cable for each phase- The actual length will be decided after finalisation of LUP drawing. 84 220 KV 630 Sq. mm single Core Copper Cable AL Sheath for HV side of 160 MVA TransformersSingle phase connection with single run cable for each phase- The actual length will be decided after finalisation of LUP drawing. 85 220 KV 400 Sq. mm Single Core Cu cable AL sheath(as per technical specification and as per requirement) forLine bays- Single phase connection with single run cable for each phase - The actual length will be decided after finalisation of LUP drawing. 86 132 KV 630 Sq. mmsingle core Cu cable AL sheath (as per technical specification and as per requirement) for connection of 132 KV side of 2 nos 160 MVA, 220/132/33 KV Transformers - Single phase connection with doublerun cable for each phase - The actual length will be decided after finalisation of LUP drawing. 87 132 KV 400 Sq. mm Single Core Cu cable AL sheath(as per technical specification and as per requirement) for connection of 132 KV side of 2 nos 50MVA, 132/33 KV Transformers and Line bays- Single phase connection with single run cable for each phase - The actual length will be decided after finalisation of LUP drawing. 88 33 KV 630 Sq.mmSingle Corecopper cable for LV side of 50MVA Transformer - Single phase connection with double run cable for each phase - The actual length will be decided after finalisation of LUP drawing. 89 33 KV 240 Sq.mmThree Core copper cable for three 33/11KV 6.3MVA Transformer , two 315KVA Transformer - Three Phase Connection with single run cable - The actual length will be decided after finalisation of LUP drawing. 90 11 KV 400 Sq.mm 3 coreCopper for 33/11KV 6.3MVA Transformer - Three Phase Connection with singlerun cable - The actual length will be decided after finalisation of LUP drawing. 91 Outdoor End Termination Kit/ cable sealing end and other required accessories for above XLPE cables as per requirement and specification : 92 For 220KV 630 Sq.mmsingle core copper cable for Line 93 For 220KV 630 Sq.mmsingle core copper cable forTransformer 94 For 220KV 400 Sq.mmsingle core copper cable for Line 95 132 KV 630 Sq.mm single Core Copper Cable for LV side of 160 MVA Transformer (single phase connection with doublerun cable for each phase ) 96 132 KV 400 Sq.mm single Core Copper Cable forHV side of 50 MVA Transformer & Line feeder(single phase connection with single run cable for each phase ) 97 33 KV 630 Sq.mmSingle Corecopper cable for LV side of 50MVA Transformer (single phase connection with two run cable for each phase) 98 33 KV 240 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer, two 315 KVA Auxiliary Transformer,( Three phase connection with single run cable ) 99 11 KV 400 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer(Three Phase Connection Single run cable) 100 Indoor End Termination Kit for above XLPEcable : Dry Plug-In type GIS Indoor Termination kitwith all its accessories complete. This includes cable connecting contact plates and cable terminal box at GIS termination of type-A, Fig -3 as per IEC 60859 with support structure and insulator as per approved drawing, technical specification /requirement as per the following cables. For 33 : Dry Heat Shrink type as per approved drawing, technical specification /requirement as per the following cables. 101 For 220KV 630 Sq.mmsingle core copper cable for Line 102 For 220KV 630 Sq.mmsingle core copper cable forTransformer 103 For 220KV 400 Sq.mmsingle core copper cable for Line 104 132 KV 630 Sq.mm single Core Copper Cable for LV side of 160 MVA Transformer (single phase connection with doublerun cable for each phase ) 105 132 KV 400 Sq.mm single Core Copper Cable forHV side of 50 MVA Transformer & Line feeder(single phase connection with single run cable for each phase ) 106 33 KV 630 Sq.mmSingle Corecopper cable for LV side of 50MVA Transformer (single phase connection with two run cable for each phase) 107 33 KV 240 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer, two 315 KVA Auxiliary Transformer,( Three phase connection with single run cable ) 108 11 KV 400 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer(Three Phase Connection Single run cable) 109 Generator 110 DG set 100KVA with all accessoriesas per Technical specification 111 Communication Equipment (As per technical specification, BOQ and mentioned Annexure) 112 Fibre Optic Terminal equipment ( with minimum five redundantdirections with MSP protection)/Optical Line Terminal Equipment (SDH-STM 4) for the Sub Station Reduntant Power Supply card and Control card etc. complete to meet Tech. Spec. Requirement in all respect ( should be compatible with FO equipment at BAPL,SLDC & Backup SLDC for data and voice communication and carrier aided protection). 113 E1 Interface cards( Minimum 16 interfaces/card) 114 Ethernet Interfaces10/100 Mbps with Layer-2 switching ( Minimum 8 interfaces/card) 115 Equipment Cabinets 116 Main Distribution Frame (100 pairs) 117 Pre-connectorised optical fibre patch cords as per requirement 118 E-1 Port Interfacing Cable 119 EPAX (with cabinet)To be suitable both for FO Equipment and PLCC equipment with 2 digit, 3 digit & 4 digit Station numbering facility and programmable features such as using analog telephone & Laptop with (4 x 8 nos.) Local Subscribers 120 Digital Teleprotection Coupler suitable for integration with SDH terminal equipment to communicate on G 703 (E1, 2 Mbps) with minimum eight commands as per Technical Specification requirement. 121 Telephone Receiver (2-wire) for connection with EPAX,to be installed at different rooms of GIS cum Control& office building, C-type quarter, Colony buildings, Security room at main gate and other areas as per direction of Site-In-Charge. 122 Telephone cable (armoured) for all2-wire telephones & other requirements as per specification and as per requirement 123 STP Data Cable(CAT 6) with flexible GI conduit pipe for data transfer and for connecting IP phones (placed at Control room, communication room, Sub-Station In-charges room etc.) with FO Panel 124 Two no. licensed software for configuration of SDH and DPC to be handed over in two pendrive to Communication wing 125 48V, 300AH VRLA type Battery 126 48V, 60A Battery Charger 127 48V DCDB as per technical specification 128 Integration withexisting Fiber Optic System at connecting Sub-Stationon optical channel (STM-4), in consultation with the OEM, whose equipment is installed at other end. i) for voice & data communication ii)for carrier aided protection purpose -with supply of equipment and material(SFP,Patchcord, etc) as required. Intigration of new SDH, with existing SDH at connecting substation must not affect repoting of existing SDH at NMS, for which necessay action needs to be taken. 129 SAS system (as perindicative Scheme diagram, Technical Specification and requirement) -Monitoring & Control of the Sub Station from a far end Operting Station in addition to local unit 130 Rack mounted Main Server (Intel XeonSilver 4215processor or higher) with KVM console with display & all accessories ( server is to be mounted at SERVER PANEL-1, for connection FO port to be considered). 131 Rack mountedStandbyServer (Intel Xeon Silver 4215 processor or higher) with KVM console with display & all accessories ( server is to be mounted at SERVER PANEL-2, for connection FO port to be considered). 132 Local HMI (client Terminal) with 32 Monitor (LED) 133 Remote HMI PC with monitor (32LED) and necessary software for remote control and monitoring via local substation Gateway ,shall support IEC60870-5-104and IEC 61850 protocol. Remote HMI shall 100% replication of local substation HMI in all respect . 134 MainGateway (Intel Xeon Silver 4215 processor or higher)-Bay level data shall report to GATEWAY & SERVER independently. support simultaneous communication with 4 independent Master stations over IEC 104 protocol. 135 Standby Gateway (Intel Xeon Silver 4215 processor or higher)- Bay level data shall report to GATEWAY & SERVER independently. support simultaneous communication with 4 independent Master stations over IEC 104 protocol 136 Disturbance Recorder Cum Engineering Workstation PC (Industrial Grade) withMonitors (24 size- LED) 137 1 no PC with monitor (24 size LED) and necessary software for remote end to fetch DR data from relays and to configure all relays . 138 Rack mounted complete GPS unit, to be mounted in server panels . 139 Laser Colour Printer (suitable for at least A3 size) 140 Dot Matrix Printer 141 PRP Compliant, managed 20 FO port Ethernet Switch, industrial grade. 142 SAS application software with required license (suitable for 8000 signals, with life time validity) and other relevant operating & system software for running the scheme successfully. 143 Redundant Inverter of 5KVA or higher capacity in HOT-STANDBY Mode, on220V station battery , to feed SERVER, GATEWAY, HMI, Engineers WorkStation,Monitors, Ethernet Switches, KVM Switches,Printers, MODEM/ROUTER, etc. 144 Cabling System -Multimode / Single Mode Dual Window armoured fibre optic approach cable as required with HDPE duct, Flexible GI Conduit, all other power & control cables, Jacks, connectors and any other hardware to meet functional / performance requirement. 145 LIU having minimum 12 ports. 146 Red Box having minimum 4 RJ45 & 2 FO ports. 147 Remote Monitoring & control (wherever required) of Station Auxilliary System like Fire Fighting System, Air Conditioning System, Battery System, Lighting System, ACDB, 220V & 48V DCDB,replica of annunciator with buzzer & reset arrangement,& fire fighting annunciatoretc. complete as per technical specification requirement. For auxilliary system, AUX BCU to be mounted in separate panel. 148 Premium quality Integrated Control console deskwith chairs and other furnituresfor HMI Workstations, DR PC, telephones, storing of log sheets & manuals etc. suitable for three operators 149 Data Integration with SLDC and Back up SLDC End Including programme as per technical specification and also as per site requirement by directly communication with agency engaged for AMC of SCADA at SLDC and Back up SLDC End. 150 Router cum firewall shall be provided at local end for remote data transmission . 151 Network panel and other material / equipment / accessories required for successful completion ofthe job . 152 Automated notification in the form of SMS - i) SMS is required to be sent to 5 (five) mobile numbers at a time. ii) When required, any number can be deleted or altered. For that easy interface is to be provided. A log (with user-id and time) for the same is also required to be maintained. iii) The type of disturbaces or trippings for which SMS to be sent must be cofigurable. iv) All required hardwares and softwares to establish the system is under scope of the bidder. v) ISP connection in the name of WBSETCL and any formalities (if required) is to be done by the Bidder.SIM will be provided by WBSETCL. vi) After handing over the system, any recurring charges for SIM will be borne by WBSETCL. 153 Vendor Assessed Quantities: 154 ACDISTRIBUTION BOARD(comprising of Main ACDB, Sub-ACDBMLDB,DB) complete as per technical specificationand as per requirement. In addition to incomers from 2 nosStation Transformer, and Diesel Generator, suitable incomer for Solar Roof Top plant (40 kWp capacity) is to be considered as per requirement for GIS building and 11 KV room . 155 DCDISTRIBUTION BOARD (220 V DC)complete as per technical specificationand as per requirement 156 30V DCDB (with single source) for 11 KV System as per uploaded Tech spec 157 Control cable 1.1KV grade( Cupper ) as per TECH Spec and as per requirement as per approved drawing and cable schedulefor entire work including cable laying fromACDB & DCDB ,paneland any other equipment and also any equipments supplied by WBSETCL including Supply and installation of all required cables as per transformer & RTCC scheme drawing . Actual quantity will be finalised as per approved drawing and cable schedule and as per requirement 158 19 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 159 16 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 160 12 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 161 8 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 162 4 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 163 5 core, PVC, Armoured4 Sq. mm Copper as per Technical Specification.(For all CT, PT & CVT connection. For CT individual colour coded cables are to be used for individual core). 164 4 core, PVC, Armoured4 Sq. mm Copper as per Technical Specification. 165 5 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 166 3 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 167 2 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 168 POWERCABLE-Multi Core, PVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification and as per requirement as per approved drawing and cable schedulefor entire work including cable laying fromACDB & DCDB ,paneland any other equipment and also any equipments supplied by WBSETCL including Supply and installation of all required cables as per transformer & RTCC scheme drawing (Allcablesshall be of Copper only.)Actual quantity will be finalised as per approved drawing and cable schedule and as per requirement 169 1C X 500 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 170 3.5C X 185 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 171 4C X 16 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 172 4C X 25 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 173 4C X 50 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 174 4C X 35 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 175 2C X 50 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 176 1C X 50 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 177 2C X 4 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 178 ACSR CONDUCTORwith accessoriesas per Technical Specification and as per requirement 179 ACSR Moose 180 ACSR Panther 181 Earth /Shield wirefor LM down comer 182 ALUMINIUM TUBULAR PIPE (Schedule 80) as per Technical Specification and as per requirement 183 3 IPS ALUMINIUM TUBULAR PIPE as per Technical Specification and as per requirement 184 2.5 IPS ALUMINIUM TUBULAR PIPE as per Technical Specification and as per requirement 185 1.5 IPS ALUMINIUM TUBULAR PIPE as per Technical Specification and as per requirement 186 CLAMPS,CONNECTORS,BUNDLE SPACER, Hardware fittings & accessoriesincluding equipment connectors(SUITABLE FOR SCH. 80) and as per approved ACSR conductor as per Technical Specification and as per requirement 187 220KV System 188 132KV System 189 33 KV System 190 11KV System 191 0.4KV System 192 Solid Core POSTINSULATOR& Anti fog type Disc insulatorwithhardware fittings and accessories as per Technical Specification andrequirement 193 220KV System 194 132KV System 195 33 KV System 196 11KV System 197 ILLUMINATION SYSTEM 198 ILLUMINATION SYSTEM COMPLETE (Both Indoor & outdoor)GIS building control building switchyard periphery C type building B type buildingPump House, Security Goomty / Barrack, DG Room,other area installation including light pole with foundation worketc as per technical specificationandrequirement. Allluminaire used shall be of LED type (irrespective of the type mention in specification) and all fans shall be of energy efficient BLDC type. 199 Dehumidifier as per specification 200 Dehumidifier with suitable capacity & size for 33 KV Switchgear Roomas per approved drawing 201 Direct Stroke Lightning Protection for GIS building(considering Roof Top Solar Plant), Control builting, FFPH, as per relevant IEC. 202 Furnitures and Gadgets for Conference Room - Premium quality furnitures of reputed brand like Godrej or equivalent are to be considered. However, before procurment of furnitures and gadgets, written approval from WBSETCL site-in-charge is to be taken. 203 Conference table suitable for 30 person 204 Executive High Back chairs 205 Digital Audio / visual projector - 4K resolution, 2 nos USB 2.0 and 2 nos HDMI 2.0 ports (Preferred make - Sony, Epson, JVC, Panasonic) 206 64 or higher Interactive smart whiteboard of reknowned make 207 Meeting room Audio system (microphones - 30 nos., wall mounted speakers, amplifiers, other required hardwares & softwares) - (Make Harman, Sennheiser or equivalent) 208 Decorative dimmable LED lights (average 500 lux level) 209 High quality window blinds matching with room interior 210 AIR CONDITIONING SYSTEM COMPLETE as per Technical Specification and as per requirement (All machines must be of same make.) 211 RelayRoom and SAS Room & communication Room- Ductable Air Conditioning System is to be considered. -All machines must be ofsame make . Considering continuous operation ,machines must be of Industrial gradeand refrigerent must be of R32 or better environmental standards .as per spec 212 5star rated Split type Non-Ductable AC for Battery & Chargerroom, In-Charge Room, Conference room DB Room etcAll machines must be ofsame make . Considering continuous operation, machines must be of Industrial grade / 5 star rated split and refrigerent must be of R32 or better environmental standards as per spec 213 FIRE FIGHTING & FIRE PROTECTION SYSTEM - As per Tech spec 214 Fire hydrant system in ring formation along the periphery of switchyard covering entire portion (Entire 132 KV Switchyard &220 KV switchyard), GIS building, Control Building etc as required. 215 Portable fire extinguisher & bucket at key locations of switchyard ,control room, GIS building, office area ,residential and other building and near each Power Transformer as per Technical spec . and as per requirement. 216 Fire Alarm System (Concealed cabling is preferred ) - i) Smoke & heat detection system covering all the rooms of GIS cum Control room building ii) adequatebeam detector with redundancyfor GIS room - as per technical specification & requirement 217 CCTV Survelliance system (as perTech specification ) - The system shall be capable to integrate with central control centre. The actual quantity shall be finalised depending on the approved design . 218 Fixed Bullet camera (short range) with all accessories -as per technical specification. 219 Fixed Bullet camera (long range) with all accessories -as per technical specification. 220 Fixed Dome camera with all accessories-as per technical specification. 221 PTZ camera with all accessories-as per technical specification. 222 IP Based Outdoor Thermal Camera with all accessories as per technical specification 223 VMS management server with 30 days recording facility for minimum 40 cameras (with MS Windows professional operating system) -as per technical specification. 224 Video surveillance software and license for 40 cameras or more (which shall be valid for lifetime) -as per technical specification. 225 40 4K Display, 24 x 7 operation; as per technical specifications 226 2 KVA online UPS with 30 minute backup-as per technical specification. 227 24 Port PoE 1G Network Switch with 4 nos SFP Ports along with 1G SM SFP Modules; as per technical specifications 228 Required number of Industrial Grade 4 Port 1G Network Switch with 2 Nos. SFP Ports along with 1G SM SFP Modules; as per technical specifications 229 Media Converter, PTZ keyboard with joystick, cabinet, junction box, POE injector, LIU, power supply, Indoor floor mount rack, outdoor rack, clamp, connector and hardware for camera fixing etc. -as per technical specification. 230 All types of armoured fibre optic cables, CAT 6 cables, armoured copper cables, HDMI cable, HDPE conduits, PVC straight pipe and accessories etc. required to complete the system-as per technical specification. 231 Computer Table, rolling Chair, additional mounting pole and Other tit-bit materials not specified above but required for successful completion of CCTV surveillance systemas per site requirement. 232 NEXT GENERATION FIREWALL/ CYBERSECURITY GATEWAY and all required hardwares & software for integration with remote Control Command & Centre AS PER TECHNICAL SPECIFICATIONS. 233 One additional viewing unitsat In-Charge Room with all required hardware and software 234 SUBSTATION EARTHING SYSTEM : As per Technical specification 235 32mm dia or higherMS rod for main earthmat grid,corner mesh and periphry for outdoor switchyard . The actual quantity shall be finalised depending on the approved design (Only design quantity with lap length without any wastage for main mat, periphry& corner mesh will be considered for payment.) The Earthmat design is to be done considering earth resistivity of 30 Ohm-m oractual measured value whichever is higher. 236 32mm dia or higherMS rod for riser below and aboveground auxiliary Mat fencing and gate earthing bending length and overlapping length as per requirement & as per approved drawing 237 GS flat for riser above ground / cable trench & other areas.Rod/pipe electrode , test link and other materials etc. - as per requirement, technical specificationand approved design/layout including earthpit. 238 Earthing for GIS enclosure and GIS building as per manufacturers recommendation including civil work. 239 Earth Link Box, SVL, Earth Strip, earth continuity cable for single bondwherever required for Earthing of allXLPE Cablecomplete at cable conductor junction point etc as per technical requirement / as per approved drawings. 240 Earth Strip and other accessories including lugs for link box etc wherever required for Earthing of allXLPE Cablecompletei as per technical requirement / as per approved drawings. 241 3 ph Earth Link Box with SVLas per technical requirement / as per approved drawings. 242 3 ph Earth Link Box with outSVL as per technical requirement / as per approved drawings. 243 1 ph Earth Link Box with SVL as per technical requirement / as per approved drawings. 244 1 ph Earth Link Box with outSVL as per technical requirement / as per approved drawings. 245 6.6 KV/3.8 KV Copper Bonding Cableas per technical requirement / as per approved drawings. 246 1.1KV Grade 240 sqmm CopperEarth continuity Cableas per technical requirement / as per approved drawings. 247 GRID CONNECTED ROOF TOP SOLAR POWER SYSTEM (As per Technical Specification) 248 5kWpSolar Roof Top plant (at the roof of GIS & Control building) having high quality mono. crystalline type solar PV module from reputed brand (as mentioned under WBSETCL Makers list), Mounting structures (Fixed Type) with Civil pedestals including civil work as per requirement. 249 i) High quality inverter from reputed brand as mentioned under WBSETCL Makers list) suitable for 40kWp solar roof top plant. ii ) All other required accessories- Data logger with CPU, LCD monitor, UPS,Metering,Junction box & distribution boxes, Type-II Surge protective device, string monitoring uints, pyrano.meter with sensors, all Cables, hardware, earthing & lightning protection materials, required furnitures & cabinets, conduits etc. to complete the system of 40kWp grid connected plant 250 Essential spares necessary for operation, routine maintenance and testing of equipment supplied for 3 years to be covered under Annual Maintenance Contract. 251 MISCELLANEOUS ITEMS -As per Technical specification 252 i) Glow signboard for name of the substation- minimum size 50 sq ft, ii) schematic SLD on glow signboard iii) Danger plate, phase plate, bay nameplate etc iv) Statutory caution boards made of mild steel of 250 mm x 200 mm and at least 2 mm thick and vitreous enamelled, white on both sides and with inscription in signal red colour on front side as required. v) Shock treatment chart in local and English language duly mounted on wooden frame with glass as required vi) Safety Slogans - to be put up in Offices and Sub-station premises (Site-in-charge may select the slogans from WBSETCL Safety Manual, Version 2.0, Page 18)vii) WBSETCLLOGO & Sub-Station Nameat main gate of Sub-Station entry with good quality durable materials 253 Ferrules & lugs, GI conduit, Cu flexible wires for panel earthing etc. 254 .Angle, Channel and other hardwares for installation of panels, DBs etc. 255 Supply of itemsfabrication marker, tags,Protection cover tiles, PVC warning tape, route marker, jointing marker, clamps connector etc as per specification & approved drawing 256 Trefoil clamp suitable for approved XLPE cable 257 Bay marshalling kiosk, dummypanel, junction box, , Lighting & other Distribution Boards etc. As per requirement& as per Technical specification 258 Bay marshalling kiosk, 259 Dummypanel, 260 Junction box, (CT,PT,CVT as per requirement 261 Distribution Boards as per requirement 262 Cable Tray (Ladder type & perforated type etc ) as per requirement for indoor cable trench and and as per requirement within GIS building 263 Industrial type Exhaust Fans and mechanised louvers of required quantity for 220KV & 132KV GIS Hall, 33 KV indoor switchgear& 11 KV Switchgear Room as per requirement & as per Tech Spec 264 HDPE Pipes 265 200 mm Dia 266 150 mm Dia 267 One storage type RO + UV + UF water purifier for office building 268 Spares:- Spare relays including test jack are to be delivered after duly tested at CTD WBSETCL on chargeble basis. All materias will be as per scheme of this project ) 269 Distance Protection relay (as approved at 220 KV Line bay for Main-1 potection) 270 Distance Protection relay (as approved at 220 KV Line bay for Main-2 potection) 271 Distance Protection relay (as approved at 132 KV Line bay for Main-1 potection) 272 Distance Protection relay (as approved at 132 KV Line bay for Main-2 potection) 273 Transformer differential Relay(same as approved for 220 KV Transformer bay) 274 Transformer differential Relay(same as approved for 132 KV Transformer bay) 275 BCU (same as approved for 220KV bays ) 276 BCU (same as approved for 132KV bays ) 277 BCU (same as approved for 33KV bays ) 278 BCU (same as approved for auxilliary system) 279 PRP Compliant, managed Ethernet Switch, industrial grade. (same as approved for SCADA Systeml) 280 Over Current& Earth fault Relay 281 Bus Bar Differential Relay (One Central Unit and one Peripheral Unit) 282 Trip Relay 283 VT selection Relay 284 Spares: Spare are to be delivered at nearest store in consultation with in charge All materias will be as per scheme of this project. 285 220KV GIS Circuit Breaker complete mechanism 286 220KV GIS Disconnector complete mechanism 287 220KV GIS High speed earth switch complete mechanism 288 132KV GIS Circuit Breaker complete mechanism 289 132KV GIS Disconnector complete mechanism 290 132KV GIS High speed earth switch complete mechanism 291 33KV CT - same as supplied for Line bay 292 33KV CT - same as supplied for 50 MVA Transformer bay 293 Safety Equipment 294 Full Body Safety Harness with Twin rope lanyard, length < 3 meter with waist belt and accessories as per IS - 3521 295 First aid box complete with all items (as perAnnexure in line with WBSETCL Safety Manual, Version 2.0) - to be placed at Control Room & Maintenance Room 296 Discharge cum earthing rod - Highly insulated FRP telescopic type with all accessories suitable for 245 KV system or higher,CPRI type tested as per IEC - 1230:1993 & IEC - 1235 with tested epoxy earthing rod for 10 KV /ft for 1 min as per IEC- 855 297 Safety Helmet - Made of Polyethylene/ glass fibre reinforced with head band, cradle, strap fittings with withstanding temp of 50oC as per IS – 2925 (Suitable stand / Racks are to be provided to store the helmets. Helmets are to be colour coded for visitors, technical staff and others) 298 Gum Boot made of Rubber (Suitable stand / Racks are to be provided for storage.) 299 Renowned make High Voltage Detector - Suitable for 11 KV to 245 KV , 50 HZ system with sensing level 1 mtr. for 132/220/ 400 KV system complete with HV probe, 5.0 mtr telescopic insulation stick with visual LED and Buzzer indication as per IS - 13771/ IS - 2071 300 Safety shoes - Double density PU sole, leather with hard Toe cap, Non-woven Eva lining, anti static /electric shock proof Insole (with minimum electrical resistance and high voltage of 18 KV), conforming to IS – 15298 301 Hand Gloves - Made of soft quality rubber, seamless latex, shock proof, for electrical purpose suitable upto33 KV -system as per IS - 4770 302 Electric Arc Protection Suit - FR suit compatible to wearwith hood, jacket, face shield, trouser etc complaint with NEFA- 70 E standard as per IEC - 61482-1-1-2007/9 303 Insulating mat - High density insulating matsasper IS - 15652 with ac(rms) kv 3.3, sizes of rolls 5000 mm X 1000 mm (to cover entire operating length of 33KV switchgear, DB room & Panel room) 304 Safety Ladder - Single step self supporting type with complete Fiber glass, 3 inch wide, antiskid fibre steps, non - slip fibre glass shoes with thick rubber pad, Height 8 ft 305 Safety Torch / Search Light - Body:- Fibre glass, PCB - glass epoxy to meet all weather condition, Circuitry - IC Control, Charge -220 Volt AC, Light Source - 12 V Halogen Bulb, 55 watt, Power source - 12 volt, 7 AH sealed battery, Extra jack tobe provided for direct lightning by 12 volt DC, Continuous run - 2 hr High beam Rechargeable Hand Held Search light 306 Lifting Rope - Hemp Rope / Sisal Rope / Manila Rope - One inch dia., 30mtr long 307 Passenger Elevator (6 person capacity, ) - For GIS & Control buildingcomplete in all respect as per technical specification and as per requirement. 308 Industrial grade Vacuum Cleaner of reputed make 309 Civil Part: 310 Supply, fabrication, galvanisaton of variousswitchyard & equipment structures,LM-Lattice type ( 35Mtr or 50 Mtr-based on DSLP Calculation), XLPE cable supporting structure completeas per approved electrical layoutdrawings and technical specification (Electrical & civil) and as per requirement complete. (including Nuts & Bolts and foundation bolts) 311 Switchyard Structures including Nuts & Bolts 312 Foundation Bolts for switchyard structures including nuts, washers and anchor plates (Foundation Bolts shall be galvanisedupto threaded length from top) 313 Supply, fabrication of various structures (MS FLAT, MS Plate, Insert plate, Angles, Transformer Rail, Channels, ISMB, Chequred plate, MS grating for GIS Building, Transformer, Cable trench , drain etc. as per approved drawings, technical specification (Electrical & civil) andrequirement complete.
BRR : 4365272
Selection, Supply, Storage, Erection, Commissioning, Trial Run, Performance Guarantee Tests, Three Years O And M Of The Electro-Mechanical Equipments For The 0.7 Mg Ugr Cum Booster Pumping Station Under Naihati Municipality Under Amrut 2.0.- 1 Supply, delivery at site and installation of vertical turbine pump motor set complete havingthe following head discharge characteristics, capable to discharge clear water,having SS(CF8M) impeller, CI casing , dischagre head ,motor stool along withother standard accessories withTEFC ,1000rpm(synchronous),6 Pole, 3 Phase, 0.415 kv± 10% AC ,insulation class F , IP 55 , squirrelcage induction motor of suitable ratingsas required.and as per technical specification and direction of EICand as per CPHEEO standard .Motor shall have a margin ofat least 30 % margin over thepump input at duty point or 10% margin over the maximum pump input inthe worst case of the pump operation in the total range (from shut-off to run out),whichever ishigher .Pumps shall be installed on suitable RCC foundationadhering to all the technical requirements of the pump manufacturer. Make : Pump :WPIL / Mather & Platt / KBL / Xylem. Motor : CGL/Marathon/Siemens/ABB 2 750 m³/hr against a tentativehead of60 to 65 m (2nos working +2 nos. standby ) (Finallyactual TDH to be determined by the tenderer at the time of detailed engineering after consultation with the concerned division dealing with the pipe laying ) 3 Supply, delivery at site, installation of 3 Panel HT Switch Board of 350 MVA, 11 KV 18.4 KA, 800 Amps complete in all respect with all other accessories as per technical specification and direction of EIC. Incomer-1no.,Transformer feeder-2 nos .Make : Schneider/ Siemens / ABB 4 Supply, delivery at site & installation of 800 KVA, 11/0.433KV , ONAN outdoor transformer complete in all respect with all other accessories and proper fencingas per technical specification and direction of EIC conforming toIS :1180 Level 1 ( Latest revision : Level 1) ( 1no. Working + 1no. Standby ) Make : KEC / Schneider / CGL 5 Supply, delivery at site, installation of LT.P.D.B.complete in all respectwith all other accessories as per technical specification( 2 nos. incomer ACB, 1 no. bus coupler , 4 nos motor feeders with soft starters ,Lighting feeders, Valve actuator feeders , EOT crane feeder, drinking water pump feeder, ventilation feederand other auxiliary feedersas requiredas per site condition and as per technical specification and direction of EIC ). Make : Sellwin Electricals Pvt. Ltd. / PCE Project Pvt. ltd / System Control / ABB. 6 Supply, delivery at site, installation of central control desk complete in all respect with all other accessories as per technical specification and direction of EIC. Make : Sellwin Electricals Pvt. Ltd. / PCE Project Pvt. ltd / System Control / ABB 7 Supply, delivery at site , installation of 1400VA noise less digital sine wave Inverter with 180AH , 12Volt Tubular Battery for emergency lighting of the plant. Make : Exide / Amaron / Microtech 8 Supply, delivery at site , fitting and fixing of electro-magnetic flow meter of following sizes ,comprisingofflow sensor and transmitter, signal conditioner if required, flow indicator, flow totaliser(controller unit ) and all other accessoriescomplete as per specification and direction of EIC. 9 500mm. 10 Supply, delivery at site fitting and fixing of following MS pipe including fabrication of all necessary accessories special viz dismantling joints, Puddle plates ( 20mm), Bell Mouth,bends, tees, enlarger/reducer, R.C.C.pedestal for common manifold , etc including cutting walls, pipes, making flanged & welded joints as required, fitting fixing complete in all respect including cost of all fitings, sundry and jointing materials as required for laying of pipe with anti-corrosive treatment of all pipe surface complete as per technical specification and direction of EIC. 11 350 mm., 10mm thick (For individual delivery piping) 12 350mm , 10mm thickDF Metallic dismantling joint with split flange, long stud, bolts, nuts etc. 13 500mm ,10mm thick (For common manifold piping) 14 500mm , 10mm thick (For flowmeterpiping) 15 Supply, delivery at site, lowering, fitting and fixing of DIDF non return valve (PN-1.6 ) of following size in proper position and alignment by providing temporary support as required including cost of all sundry materials such as gaskets, nuts, bolts etc. all complete as required to complete the job in all respect as per technical specification and direction of EIC. 16 350 mm,dia (for individualpump delivery side) 17 Supply, delivery at site, lowering, fitting and fixing of DIDF butterfly valve (PN-1.6) alongwith suitable rated motorised actuator of following size in proper position and alignment by providing temporaray support as required including cost of all sundry materials such as gaskets, nuts, bolts etc all complete as required to complete the job in all respect as per technical specification and direction of EIC. 18 350 mm dia(for individual pump delivery line) 19 500 mm dia (for common header ) 20 Supply, delivery at site, fitting and fixing of gun metal gate/globe / check valve for drinking water lines including1 HP submersible pump ,starter panel , etc complete with all accessories including cost of all sundry materials and fitting fixing charges as required as per technical specification and direction of EIC. 21 50mm dia Gate / Globe Valve 22 32mm dia Gate / Globe Valve 23 50mm dia Check Valve 24 Supply, delivery at site, fitting and fixing of single orifice type air release valve with isolation valveof adequate size for manifold pipe line complete with all other standard accessories including cost of all sundry materials and fitting fixing charges as required as per technical specification and direction of EIC. 25 50 ARV 26 100 ARV 27 Supply, delivery at site, fitting and fixing of dust & damp proof following field instruments complete with all valves, cocks and other fixtures including cost of all sundry materialsas required as per technical specification and direction of EIC. 28 0-10 kgf/cm² (6 dial bourdon type for individual delivery line,accuracy ± 1%) 29 0-10 kgf/cm² (8 dial bourdon type for common delivery manifold,accuracy ± 1%) 30 Pressure transmitter including cabling (For individual delivery line ) 31 Pressure transmitter including cabling (For common delivery manifold ) 32 Supply, delivery at site fitting and fixing of theultra sonic water level sensor with indicator including transmitter / transducer / stilling pipe and all other accessories including all cabling connections all complete as per specification and direction of EIC. 33 Supply, delivery at site fitting and fixing of float typemechanical level indicator and staff including all other accessories as per specification and direction of EIC. 34 Supply ,delivery at site and laying of 11 KV grade XLPE insulated, PVC outer sheathed, armoured, aluminium conductor cable of following size either through cable duct or through cable trays or through protection pipesas per technical specification and direction of EIC. 35 3 core x 300 mm²( WBSEDCL room to KMDA HT Panel) . 36 Supply, delivery at site and laying of 11 KV & 1.1 KV grade XLPEinsulated, PVC outer sheathed,armoured, aluminium conductor cable of following size either through cable duct or through cable trays or burried underground through brick protection or through protection pipesas per technical specification and direction of EIC. 37 3core x As required mm²from KMDA HT panel to transformer 38 3.5 core x As requiredmm² Transformer to LT Panel 39 3 core x As requiredmm²LT Panelto Motor 40 Supply, delivery at site and laying of 1.1KV grade XLPE insulated, PVC outer sheathed, armoured/unarmoured , stranded aluminium /copper conductor for auxiliary power , controlcable andsignal cable of required size either through cable duct or through cable trays or through protection pipesas per technical specification and direction of EIC. 41 Making end termination of 11KV grade 3 core x 300 mm² XLPE and other HT cables, insulated, PVC outer sheathed,armoured,aluminium conductor cable with push on type premoulded cable jointing kit indoor/ outdoor type as required complete with gland and other hardwares as per direction of EIC. 42 Making end terminationof 1.1KV grade XLPE/PVC insulated armoured Al./Cu. conductor cable with gland and other hardwares as requiredas per direction of EIC 43 Supply, delivery, fitting and fixing sheet steel fabricated double door type 4+ 4 way TPN MCB distribution board with 1 no 63A 4 pole isolator and 12 nos 6 — 32 Amps. SPMCB on wall as per direction of the EIC. 44 Supply, delivery at site, installation of control panel,sheet steel fabricated complete in all respect with all accessories for control of exhaust fans and other emergency loads as per technical specification and direction of EIC. 45 Distribution wiring with 1.1KV grade 2 X 1.5 mm² PVC insulated unsheathedsingle core stranded copper wire in 20mm G.I. conduit to light, fan, call bell point with 10A DP toggle switch fixed on 3mm thick bakelite cover in double door sheet metal switch board with magetic locking arrangement as per direction of the EIC. 46 Distribution wiring with 1.1KV grade 2 X 2.5 mm² PVC insulated unsheathedsingle core stranded copper wire in 20mm G.I. conduit to 250 V 15 A 6 pin compositeplug socket fixed on 3mm thick bakelite cover in double door sheet metal switch board with magetic locking arrangement including 1 X 1 mm²PVC insulated unsheathed single corestranded copper wire as earth continuity wire. 47 Wiring with 1.1KV grade 3 X 1.5 mm² PVC insulated unsheathed single core stranded copper wire in 20mm G.I. conduit including 1 X 1 mm²PVC insulated unsheathed single core stranded copper wireas earth continuity wire from starter control panel to exhaust fan point. 48 Supply and fixing ofIndustrial type LEDTube Light fittingof make Philips , model (EnduraLED) BN308LC LED40S-6500 L120 PSU WH, completely wired up with necessary accessories , as required to maintain lux level as per IEC & as per specification & direction of EIC. 49 Supply and fixingstreet lights of make Philips , model- BRP410 LED 110 CW HE MR FG S2 PSU GRLED fitting completely wired up with necessaryaccessoriesincluding fixing on pole as requiredto maintain lux level as per IEC &as per specification & direction of EIC. 50 Supply and fixing of 70 W SON post top luminaries or equivalent LED fittingcompletely wired up with necessary ignitor, ballast, capacitor and lamp etc including S & F of G.I. pipe bracket on wall as requiredto maintain lux level as per IEC & as per specification & direction of EIC. 51 Supply and fixing ofhighbay luminaries of make Philips , model- Durabay Prime BY225P LED100S CW WB PSU FG GR V1 , LED fitting completely wired up with necessary accessories , including S&F of M.S. clamp on ceiling as required as perto maintain lux level as per IEC & specification & direction of EIC. 52 Supply and fixing of 300mm Sweep, 230 V, 1Ph, 50 Hz, 4 pole exhaust fan including S & F of M.S. cowl and making suitable hole in the wall including mending good damages completeas per specification & direction of EIC. 53 Supply and fixing of 600mm Sweep, 415 V, 3Ph, 50 Hz, 6 pole exhaust fan including S & F of M.S. cowl and making suitable hole in the wall including mending good damages completeas per specification & direction of EIC. 54 Supply and fixing of 1200mm Sweep, 230 V, 1Ph, 50 Hz, ceiling fan including S & F of electronic regulator as per specification & direction of EIC. 55 Supply and fixing of 450mm Sweep, 230 V, 1Ph, 50 Hz, 4 pole pedestal type air circulator as per specification & direction of EIC. 56 Fabrication and installation of structural steel works such as, cable duct cover by chequered plates, pipe & valve supports, valve operating platform,walkway ,cable supports, trays, hangers as required as per specification & direction of EIC. 57 Supply and fixing of 600mm Sweep, 230 V, 1Ph, 50 Hz, 4 pole wall bracket type air circulator as per specification & direction of EIC. 58 Supply, delivery and erection of 9.0 mtr long G.I.Pole fabricated from M.S. sheet incl. earthing of individual & light fittings as per design and direction of EIC. 59 Supply and fixing of G.I. Bracket Arms suitable for theG.I. Pole with necessary pole cap,hardwares etc as required as per design and direction of EIC. 60 Twin Arm upto 2M long 61 Single Arm upto 2M long 62 Supply, delivery, fitting,fixing of fire extinguishers complete in all respect i.e. with first charge of refill, mounting bracket etc. as per technical specification and direction of EIC. 63 Portable type fire extinguisher (2 Kg Capacity) 64 5Kg. Capacity (ABC Type) 65 Supply and fixing on wall or on stand of 9 Ltrs capacity M.S. bucket, 50% of the bucket capacity to be filled with sand as per direction of EIC. 66 Earthing the whole installation as per IE Rules & Acts, specifications, complete in all respect including supply,installation of all required earthing materials,flats,earth electrodes and all other sundries,fitting,fixtures including making proper earth stations as per technical specification and direction of EIC. 67 Providingfencing with structural gates around the periphery of the transformer yard as per I.E. rules including supply and fixing of necessary M.S. angles, flates G.I. mesh etc. as required to complete the job as per specification and direction of EIC. 68 Supply and fixing of E.I. Danger board on wall & fencing as per direction of EIC 69 Supply and providing 11KV grade rubber matas per direction of EIC. 70 Supply and fixing on wall a shock treatment chart duly framed by polished wood and the glass fitted in front complete as per direction of EIC. 71 Display of back lit & non lit sign board of various sizes on the pump house wall fascia or elsewhere as per direction of EIC. 72 Supply ,installation & commissioning,of 5 MT doublegirder capacity EOT crane complete in all respect including testingas per technical specification and direction of EIC. 73 Painting the whole installationas per technical specifcation and direction of EIC. 74 Carrying out high pressure test of the HT installation by approved agency and obtaining necessary clearance fron Directorate of Electricity as per direction of EIC. 75 Supplyof drawings for approval and finally as-built drawings in 6sets and CDs . 76 Supply, delivery at site & laying of MS pipe including fabrication of all necessary accessories special ,enlarger,,R.C.C./ fabricated pedestal ,thrust blocks , etc including cutting pipes, making flanged & welded joints as required, for joiningthe common deliverymanifolds with the existingprelaid rising main pipescomplete as per technical specification and direction of EIC.Note : Any mechanical or electrical or civil , parts/spare/equipment not included in the BOQ but required to complete the project is to be supplied by the agency at free of cost i.e.cost of such items shall be included within this offer. 77 Operation and maintenance of the entireCWPS incl. supply of consumables for a period of five years along with deputationoftrained staffs as required to run the pumping station. 78 1 styear 79 2 nd year 80 3 rd year
BRR : 7877869
Supply, Delivery And Installation Of Pumping Machinery And Allied Accessories At Existing Ugr Pump House At Lake Town Location Under South Dum Dum Municipality, Kolkata -700089 Under Amrut 2.0(Phase-Ii)- 1 Supply, delivery at site and installation of vertical turbine pump motor set complete havingthe following head discharge characteristics, capable to discharge clear water,having SS(CF8M) impeller, CI casing , dischagre head ,motor stool along withother standard accessories with Premium Efficiency (IE3), TEFC ,1500rpm(synchronous),4Pole, 3 Phase, 0.415 kv± 10% AC ,insulation class F , IP 55 , squirrelcage induction motor of suitable ratingsas requiredand as per technical specification and direction of EICand as per CPHEEO standard .Motor shall have a margin of 1.3 over the pump BKW at duty point. Pumps shall be installed on suitable RCC foundationadhering to all the technical requirements of the pump manufacturer. 2 800m³/hr against a tentativehead of50 to 62 MWC(2nos working + 2no. Standby ) 3 1150 m³/hr against a tentativehead of 11 to 20 MWC(1nos working + 1no. Standby ) 4 (Finallyactual TDH to be determined by the tenderer at the time of detailed engineering after consultation with the concerned division dealing with the pipe laying ) 5 Supply, delivery at site, installation of 3-Panel HT Switch Board of 500 MVA, 6.6 KV 26.3 KA, 800 Amps complete in all respect with all other accessories as per technical specification and direction of EIC. (For KMDA HT Room ) 6 Supply, delivery at site, installation ofminimum800 KVA, 6.6/0.433KV as required (To be finalised during detail Engineering ), ONAN outdoor Transformer complete in all respect with all other accessories as per technical specification and direction of EIC conforming toIS :1180 Level 2 ( 1no. Working + 1no. Standby ) 7 Supply, delivery at site, installation of LT.P.D.B. cum MCCcomplete in all respect along with capacitor banks as required with all other accessories as per technical specification and direction of EIC. ( 2 nos. incomer ACB, 1 no. bus coupler , 6 nos. Soft starter for motor feeder, Lighting feeders, Valve actuator feeders , EOT crane feeder, drinking water pump feeder and other auxiliary loads as requiredas per technical specification and direction of EIC ) 8 Supply, delivery at site, installation of central control desk complete in all respect with all other accessories as per technical specification and direction of EIC. 9 Supply, delivery at site, installation of 30Volt DC Battery Charger with maintenance free battery complete in all respect with all other accessories as per technical specification and direction of EIC.(requirement or capacity to be determined during detailed engineering) . 10 Supply, delivery at site , installation of 1400VA noise less digital sine wave Inverter with 180AH , 12Volt Tubular Battery for emergency lighting of the plant. 11 Supply, delivery at site , fitting and fixing of electro-magnetic flow meter of following sizes ,comprisingofflow sensor and transmitter, signal conditioner if required, flow indicator, flow totaliser (controller unit ) and all other accessoriescomplete as per specification and direction of EIC. 12 500mm. 13 450 mm. 14 Supply, delivery at site fitting and fixing of following MS pipe including fabrication of all necessary accessories special viz dismantling joints, Puddle plates(20mm), Bell Mouth,bends, tees, enlarger/reducer, R.C.C.pedestal for common manifold , etc including cutting walls, pipes, making flanged & welded joints as required, fitting fixing complete in all respect including cost of all fitings, sundry and jointing materials as required for laying of pipe with anti-corrosive treatment of all pipe surface complete as per technical specification and direction of EIC. 15 350 mm.,8mm thick (For individual delivery piping) 16 350mm ,8mm thickDF Metallic dismantling joint with split flange, long stud, bolts, nuts etc. 17 500mm ,8mm thick (For common manifold piping) 18 500mm ,8mm thick (For flowmeterpiping) 19 450 mm.,8mm thick (For individual delivery piping) 20 450mm ,8mm thickDF Metallic dismantling joint with split flange, long stud, bolts, nuts etc. 21 450mm ,8mm thick (For common manifold piping) 22 450mm ,8mm thick (For flowmeterpiping) 23 Supply, delivery at site, lowering, fitting and fixing of DIDF non return valve (PN-1.0 ) of following size in proper position and alignment by providing temporary support as required including cost of all sundry materials such as gaskets, nuts, bolts etc. all complete as required to complete the job in all respect as per technical specification and direction of EIC. 24 350 mm dia with head stock (for individual pump delivery line) 25 450 mm dia with head stock (for individual pump delivery line) 26 Supply, delivery at site, lowering, fitting and fixing of DIDF butterfly valve (PN-1.0) alongwith suitable rated motorised actuator of following size in proper position and alignment by providing temporaray support as required including cost of all sundry materials such as gaskets, nuts, bolts etc all complete as required to complete the job in all respect as per technical specification and direction of EIC. 27 350 mm dia with head stock (for individual pump delivery line) 28 500 mm dia (for common header ) 29 450 mm dia with head stock (for individual pump delivery line) 30 450 mm dia (for common header ) 31 Supply, delivery at site, fitting and fixing of single orifice type SS air release valve with isolation valveof adequate size for manifold pipe line complete with all other standard accessories including cost of all sundry materials and fitting fixing charges as required as per technical specification and direction of EIC. 32 Supply, delivery at site, fitting and fixing of dust & damp proof following field instruments complete with all valves, cocks and other fixtures including cost of all sundry materialsas required as per technical specification and direction of EIC. 33 Pressure Guage 0-10 kgf/cm² (6 dial bourdon type for individual delivery line,accuracy ± 1%) 34 Pressure Guage 0-10 kgf/cm² (8 dial bourdon type for common delivery manifold,accuracy ± 1%) 35 Pressure transmitter including cabling (For individual delivery line ) 36 Pressure transmitter including cabling (For common delivery manifold ) 37 Supply, delivery at site fitting and fixing of theultra sonic water level sensor with indicator including transmitter / transducer / stilling pipe and all other accessories including all cabling connections all complete as per specification and direction of EIC. 38 Supply, delivery at site fitting and fixing of float typemechanical level indicator and staff including all other accessories as per specification and direction of EIC. 39 Supply ,delivery at site and laying of 11 KV grade XLPE insulated, PVC outer sheathed, armoured, aluminium conductor cable of following size either through cable duct or through cable trays or through protection pipesas per technical specification and direction of EIC. 40 3 core x 300 mm²( WBSEDCLroom to KMDA HT panel to transformer ) . 41 Supply, delivery at site and laying of 1.1KV / 11 KVgrade XLPEinsulated, PVC outer sheathed,armoured, aluminium conductor cable of following size either through cable duct or through cable trays or burried underground through brick protection or through protection pipesas per technical specification and direction of EIC. 42 3.5 core x As required mm² TXR(LT) to LT panel. 43 3 core x As requiredmm² LT motor feederto motor terminal 44 Supply, delivery at site and laying of 1.1KV grade XLPE insulated, PVC outer sheathed, armoured/unarmoured , stranded aluminium /copper conductor for auxiliary power , controlcable andsignal cable of required size either through cable duct or through cable trays or through protection pipesas per technical specification and direction of EIC. 45 Making end termination of 11KV grade 3 core x 300 mm² XLPEinsulated, PVC outer sheathed,armoured,aluminium conductor cable with push on type premoulded cable jointing kit indoor/ outdoor type as required complete with gland and other hardwares as per direction of EIC. 46 Making end terminationof 1.1KV grade XLPE/PVC insulated armoured Al./Cu. conductor cable with gland and other hardwares as requiredas per direction of EIC 47 Supply, delivery, fitting and fixing sheet steel fabricated double door type 4+ 4 way TPN MCB distribution board with 1 no 63A 4 pole isolator and 12 nos 6 — 32 Amps. SPMCB on wall as per direction of the EIC. 48 Supply, delivery at site, installation of control panel,sheet steel fabricated complete in all respect with all accessories for control of exhaust fans and other emergency loads as per technical specification and direction of EIC. 49 Distribution wiring with 1.1KV grade 2 X 1.5 mm² PVC insulated unsheathedsingle core stranded copper wire in 20mm G.I. conduit to light, fan, call bell point with 10A DP toggle switch fixed on 3mm thick bakelite cover in double door sheet metal switch board with magetic locking arrangement as per direction of the EIC. 50 Distribution wiring with 1.1KV grade 2 X 2.5 mm² PVC insulated unsheathedsingle core stranded copper wire in 20mm G.I. conduit to 250 V 15 A 6 pin compositeplug socket fixed on 3mm thick bakelite cover in double door sheet metal switch board with magetic locking arrangement including 1 X 1 mm²PVC insulated unsheathed single corestranded copper wire as earth continuity wire. 51 Wiring with 1.1KV grade 3 X 1.5 mm² PVC insulated unsheathed single core stranded copper wire in 20mm G.I. conduit including 1 X 1 mm²PVC insulated unsheathed single core stranded copper wireas earth continuity wire from starter control panel to exhaust fan point. 52 Supply and fixing ofIndustrial type LEDTube Light fittingof make Philips , model (EnduraLED) BN308LC LED40S-6500 L120 PSU WH, completely wired up with necessary accessories , as required to maintain lux level as per IEC & as per specification & direction of EIC. 53 Supply and fixingstreet lights of make Philips , model- BRP410 LED 110 CW HE MR FG S2 PSU GRLED fitting completely wired up with necessaryaccessoriesincluding fixing on pole as requiredto maintain lux level as per IEC &as per specification & direction of EIC. 54 Supply and fixing ofhighbay luminaries of make Philips , model- Durabay Prime BY225P LED100S CW WB PSU FG GR V1 , LED fitting completely wired up with necessary accessories , including S&F of M.S. clamp on ceiling as required as perto maintain lux level as per IEC & specification & direction of EIC. 55 Supply and fixing of 300mm Sweep, 230 V, 1Ph, 50 Hz, 4 pole exhaust fan including S & F of M.S. cowl and making suitable hole in the wall including mending good damages completeas per specification & direction of EIC. 56 Supply and fixing of 600mm Sweep, 415 V, 3Ph, 50 Hz, 6 pole exhaust fan including S & F of M.S. cowl and making suitable hole in the wall including mending good damages completeas per specification & direction of EIC. 57 Supply and fixing of 1200mm Sweep, 230 V, 1Ph, 50 Hz, ceiling fan including S & F of electronoc regulator as per specification & direction of EIC. 58 Supply and fixing of 450mm Sweep, 230 V, 1Ph, 50 Hz, 4 pole pedestal type air circulator as per specification & direction of EIC. 59 Fabrication and installation of structural steel works such as, cable duct cover by chequered plates, pipe & valve supports, valve operating platform,walkway ,cable supports, trays, hangers as required as per specification & direction of EIC. 60 Supply and fixing of 600mm Sweep, 230 V, 1Ph, 50 Hz, 4 pole wall bracket type air circulator as per specification & direction of EIC. 61 Supply, delivery and erection of 9.0 mtr long G.I.Pole fabricated from M.S. sheet incl. earthing of individual & light fittings as per design and direction of EIC. 62 Supply and fixing of G.I. Bracket Arms suitable for theG.I. Pole with necessary pole cap,hardwares etc as required as per design and direction of EIC. 63 Twin Arm upto 2M long 64 Single Arm upto 2M long 65 Supply, delivery, fitting,fixing of fire extinguishers complete in all respect i.e. with first charge of refill, mounting bracket etc. as per technical specification and direction of EIC. 66 Portable type fire extinguisher (4 Kg Capacity type) 67 6 Kg. Capacity (ABC Type) 68 Supply and fixing on wall or on stand of 9 Ltrs capacity M.S. bucket, 50% of the bucket capacity to be filled with sand as per direction of EIC. 69 Earthing the whole installation as per IE Rules & Acts, specifications, complete in all respect including supply,installation of all required earthing materials,flats,earth electrodes and all other sundries,fitting,fixtures including making proper earth stations as per technical specification and direction of EIC. 70 Providingfencing with structural gates around the periphery of the transformer yard as per I.E. rules including supply and fixing of necessary M.S. angles, flates G.I. mesh etc. as required to complete the job as per specification and direction of EIC. 71 Supply and fixing of E.I. Danger board on wall & fencing as per direction of EIC 72 Supply and providing 11KV grade rubber matas per direction of EIC. 73 Supply and fixing on wall a shock treatment chart duly framed by polished wood and the glass fitted in front complete as per direction of EIC. 74 Display of back lit & non lit sign board of various sizes on the pump house wall fascia or elsewhere as per direction of EIC. 75 Painting the whole installationas per technical specifcation and direction of EIC. 76 Carrying out high pressure test of the HT installation by approved agency and obtaining necessary clearance fron Directorate of Electricity as per direction of EIC. 77 Supplyof drawings for approval and finally as-built drawings in 6sets and CDs . 78 Supply, delivery at site & laying of MS pipe including fabrication of all necessary accessories special ,enlarger,,R.C.C./ fabricated pedestal ,thrust blocks , etc including cutting pipes, making flanged & welded joints as required, for joiningthe common deliverymanifolds with the existingprelaid rising main pipescomplete as per technical specification and direction of EIC. Note : Any mechanical or electrical or civil , parts/spare/equipment not included in the BOQ but required to complete the project is to be supplied by the agency at free of cost . 79 Commissioning of whole system & Performance test for 72 hours 80 Monitoring of the newly installed electromechanical equipment for a period of one year along with consumable materials as required. 81 Dismantling and removing the existing damaged equipments from their present place and stacking them to suitable place within distance of 25km as per direction of EIC(pumps, motors,valves,HT panel,canles,pipes ,etc)
BRR : 3687189
Supply & Installation Commissioning And Comprehensive Support Of Machinery For Common Facility Centre Of Stitchers Garments Manufacturing And Home Furnishing Association Chalisgaon, Dist.- Jalgaon, State-Maharashtra, India.1 Fabric Inspection Fabric Inspection Cum Relaxing Machine- 220Cm- Width With Air Blow- Maximum Speed 150 Mtrs / M, Average Speed 40M / M, Maximum Width 180 Cm To 220 Cm, Maximum100kg, Maximum Roll Dia 50Cm Capacity 2 Pattern Making Cad-Software ( Pds+Bn+Vis ) -Automatic Digitizing, Native Files Importations, Pattern Creation, Modification, Adjustment, Size Grading, And Technical Sheet, Manual And Automatic Nesting, Queue Management. Made In Italy 3 Automatic Fabric Cutting Plotter 180- 2 Head -Power Consumption 70W / 180 W, Interface- Usb Or Lan ( Optional ) , Inkjet -Hp2 / 4, Paper 18-120 Gr / Automatic Spreader-Maximum Speed 100Mtrs / Min, Width Available 180-230Cm, Max.Capacity 100Kg, Maximum Roll Dia- 50Cm, Voltage 400V 3Ph 50 / 60 Hz, Spreading Modes, Face Up / One Way And Zig Zag With Or Without Ends Cut ( Lap Laying ) Cradle With Double Pvc Belt, Omron Plc, Auto Diagnosis System, Electronic Tension Free Device, Auto Edge Alignment By Photocells, Encoder Device, Fabric Usage Report -Made In Italy Air Blow Table ( 1Mtrx1.8Mtrx30 ) Air-Blowing Spreading Table With Metalic Oven Painted Structure. Table Top In Medium Ecotype Laminated In White Colour And Holes To Blow Air, Stell Side Rails 60X 30Xx2mm For Morgan Spreaders To Run Suction 6Of 6 M, Complete With Blowing Motor And Electric Panel 4 Manual Spreading Machine Accessories Fabric Cutting Straight Knife Cloth Cutting Machine - 8Engineered With A Low Profile, Polished And Streamlined Baseplate Designed To Reduce Friction And Distortion Of Material, Regardless Of The Number Of Plies-Straight Knives – High-Speed Reciprocating Cutting Technology Designed For Cutting Patterns, As Well As Straight Lines In Multiple Thicknesses Of Material-Made In Usa Staright Knife Cloth Cutting Machine -8Blue Streaks Engineered With A Low Profile, Polished And Streamlined Baseplate Designed To Reduce Friction And Distortion Of Material, Regardless Of The Number Of Plies- Made In Usa End Cutter -Drastically Reducing The Waste That Ends Up On The Cutting Room Floor, The Falcon Series Eliminates The Need For Excessive Selvage. Available To Cut 48-144 Inch Wide Material ( 1.22- 3.66 M ) , These Systems Are Known For Their Quality, Versatility And Ease Of Use. The Range Of Models And Configurations Ensures That Eastman Has The Right Equipment For Your Material And Specifications Band Knife - Table Size-1200Mmx1600mm, Cutting Capacity-180Mm, Variable Speed , Arm Size 700Mm Round Knife -Round Knives – Commonly Used To Cut Straight Lines Or Large Radius Curves Cloth Drill -Drills / Marking / Special Applications – Make Buttonholes, Darts, Or Other Markings; Pattern Perforating, Bundling, Strip Cutting, And Rag Manufacturing Home Textiles Needle Detector -Magnetic Induction, Buzzer, Lamp-Alarm , 32 Mtrs Per Minute , Detecting Height- 100Mm Handy Needle Detector Machine Therefore Production Is Greatly Increased. The Automatic Belt Warping Prevention Device Keeps Both The Upper And Lower Belts In The Same Position. Using The Feedback System, Damage Is Prevented. ( Patent Pending ) Using The Electronic Thermostat And The Ssr, The Temperature Difference’S Range Is Kept At ±3℃. The Ssr’S Electronic Parts Have No Contact Points Making For Durability. Various Stackers Can Be Used With This Machine. This Machine Has A Front Conveyor Belt Which Greatly Increases Production Levels. The Rotary Strip Off Device Can Be Attached As Optional Equipment. By Pushing The Heater Control Switch The Temperature Of The Upper And Lower Or Front And Rear Heater Can Be Easily Controlled. This Means Various Materials Can Be Used Safely. The Pressure Roller Is Covered With A Layer Of Silicon Rubber. The Upper And Lower Pressure Rollers Are Completely Separated When The Pressure Is Set At 0. The Heating Plate Is Covered With Special Hard Alumite, Making It Durable. The Exchange Of Belts Is Very Easy. The Belt Stopping Device Stops The Belt Automatically If The Belt Warps Therefore Protecting The Belt. The Entrance Of The Feed In Point Can Be Adjusted Easily According To The Thickness Of The Material And Interlining Being Used. An Anti-Puckering Roller Is Installed In This Machine. This Roller’S Position Can Be Adjusted. Wing Tables Can Be Attached To The Work Table. When These Tables Are Not In Use, They Can Be Folded Down. ( Option ) 6 Head 12 Colour Computerized Emboidery Machine -Needle: 12 Head: 06 Area: 400 850 1300 Stable Running Speed: 1200Rpm Maximum Speed: 1400Rpm Dahao 10 Inch A18 Computer With Head Selection Original Dahao Servo Motor For Main Shaft Motion – 3.0Kw Original Dahao Servo Motor X-Y Shaft Motion Servo Motor Cutter For Silent Trimming Action As Well As Perfect Trimming Effect Utc And Uth ( Under Thread Breakage Detecting And Upper Thread Holding Facility ) Double Cam Triple Lever High Speed Head With Jump Solenoide Original Japan Hirose 1.6X Jumbo Rotary Hook, Head To Head Oiling Facility Latest 5Cm Linear Guide Rail With Leveling Plate To Sure Exact Parallel And Levels Ultra Si E Collar Bearing Applied For Unix Guide Rail Base Ultra Si E Shaft Applied On Main Shaft Special Big Foot Pad To Run Machine Stable At High Speed With Standard Spare Parts And Accessories 8 Head Chennile Embroidery Machine ( China ) - Original Dahao System, Dahao Servo Motors, Latest High Speed Chenille Heads And Flat Bed Embroidery Machine With 9 Colour , With Standard Accessories 18- Head, 12 Colour Embroidery Machine With Double Sequins &Cording Needle: 12 Head: 18 Area: 4001300 Stable Running Speed: 1200Rpm Maximum Speed: 1400Rpm Dahao 10 Inch A18 Computer With Head Selection Original Dahao Servo Motor For Main Shaft Motion – 3.0Kw Original Dahao Servo Motor X-Y Shaft Motion Servo Motor Cutter For Silent Trimming Action As Well As Perfect Trimming Effect Utc And Uth ( Under Thread Breakage Detecting And Upper Thread Holding Facility ) Double Cam Triple Lever High Speed Head With Jump Solenoide Original Japan Hirose 1.6X Jumbo Rotary Hook, Head To Head Oiling Facility Latest 5Cm Linear Guide Rail With Leveling Plate To Sure Exact Parallel And Levels Ultra Sie Collar Bearing Applied For Unix Guide Rail Base Ultra Sie Shaft Applied On Main Shaft Special Big Foot Pad To Run Machine Stable At High Speed With Standard Spare Parts And Accessories Screw Air Compressor With 500 Ltr Tank, Air Filter And Dryer E4 Advance Digitizing Soft Ware For Embroidery Design Punching Carding And Pillow Filling Machine With Pillow Vaccum Machine Computerized Frame Type Quilting Machine ( Lifting Head ) . Richpeace 1:1 Design, Fixed Frame, Moveable Sewing Head And Saddle, Improved Quilting Precision And Max. Quilting Si E Up To 3.2M. 2. Minimied Installation Area, Solves The Traditional Machine Problem Of Large Area Of 2Times Or 4Times More, And Takes Full Use Of The Plant. 3. Max. Speed Is 3000Rpm, Suggested Working Speed Is 2500Rpm To 2800Rpm. 4. Automatic Lifting Head, Sewing Head Will Lift Up Automati Cally After Quilting For Frame Changing Easily. Special Designed Sewing Head With Independent Presser Foot Drive Is Suitable For Different Material. 5. Retractable Quilting Frame, Can Be Adjusted Freelyaccording To The Required Quilting Sie. 6. Four Japanese Panasonic Servo Motors Provide Powerful And Accurate Driving Force. 7. The Gap Between Needle And Rotary Hook Is Not The Needle To Needle Design, Which Reduces The Wear Between The Rotary Hook And Prolongs The Service Life Of The Hooks. 8. Japanese Koban Jumbo Rotary Hook And Bobbin Case. 9. Broken Thread Detection: Automatically Stop After Thread Is Broken, And The Machine Will Return Back The Broken Point To Quilt After Threading Automatically F Multi Needle Quilting With Embroidery Machine- Single Roll, Long Roller, Designed For Home Textile Wide Fabric Roll Application. Automatic Alternative Heads Feature, For Super Big Size Pattern, Automatic Thread Trimming, Colour Changing Or Pattern Spanning With Auto Thread Cutting, Reduce Manual Trimming Work.Automization Oiling System, Lubricating Machine Head And Rotary Hook Components Round, Longer Machine Life -Time.Four Needles Each Head, For Multi Colour Product.Japan Kiban Jumbo Rotary Hook With Richpeace Professional Design Software . Mainly For Summer Quilt, Bed Cover, Pillow Case, Curtain, Mattress, Protective Pad...Etc Direct Drive Single Needle Lock Stitch Machine Auto Thread Trimmer, Electric Auto Foot Lifter , 5000 Rpm , Complete Set Direct Drive, Electronic 3 Step Zig Zag Machine, Complete Set With Inbuilt Designs , Complete Set Single Needle Straight Lock Stitch Machine With Edge Cutter Speed 4500Rpm , Complete Set Semi Dry Head Double Needle Lock Stitch With Fix Bar And Thread Trimmer , Complete Set Semi Dry Head Double Needle Lock Stitch With Split Bar And Thread Trimmer, Complete Set 2 Needle Feed Off The Arm With Double Chain Stitch Machine With Cloth Puller, Complete Set Computer Controlled Bartacking Machine, 3500Rpm, Complete Set Uter Controlled Lock Stitch Button Holing Machine, Complete Set Computer Controlled, Direct Drive , Lock Stitch Button Sewing, Complete Set Computer-Controlled Eyelet Button Hole Machine With Thread Trimmer, With Sub Merged Table, Complete Set Direct Drive Two Needle Four Thread Overlock Machine With Speed 7000 Rpm And Dlc Coated Needle Bar And Upper Looper Assy, Castor Wheels -Complete Set Made In Japan Direct Drive Two Needle Five Thread Safety Stitch Machine With Speed 7000 Rpm And Dlc Coated Needle Bar And Upper Looper Assy-Castor Wheels, Complete Set Made In Japan Direct Drive 3 Needle 5 Thread Flatbed Flat Lock Machine For Plain Seeming, & Tape Binding & Auto Foot Lifter With Conversion Kit For Binding & Cover Stitch, Castor Wheels, Complete Set - Made In Japan Direct Drive 3 Needle 5 Thread Cylinder Bed Flat Lock Machine With Left Hand Fabric Trimmer, And Pneumatic Top And Bottom Thread Trimmer, Castor Wheels, Complete Set - Made In Japan 4 Needle , Flatbed Multi Functional Machine With Smooth Puller For Shirt Fronting, Castor Wheels, Stitching Machines Complete Set-Made In Japan 4 Needle , 8 Thread , Flat Bed , Double Chain Stitch Machine With Rear Puller For Attaching Elastitc , Castor Wheels, Complete Set, Made In Japan 4-6 Needle , Flatbed , Double Chain Stitch Machine With Puller For Waist Band Attaching , Castor Wheel, Complete Set-Made In Japan 2 Needle , Flat Bed , Making Belt Loop Machine With Front Fabric Trimmer, Catrol Wheel, Complete Set Value Addition 4 Needle , 8 Thread , Flat Bed , Double Chain Stitch Machine With Rear Puller For Attaching Elastitc , Castor Wheels, Complete Set, Made In Japan 4-6 Needle , Flatbed , Double Chain Stitch Machine With Puller For Waist Band Attaching , Castor Wheel, Complete Set-Made In Japan 2 Needle , Flat Bed , Making Belt Loop Machine With Front Fabric Trimmer, Catrol Wheel, Complete Set 12 Needle , Flatbed, Double Chain Stitch Machine For Pin Tucking Can Be Changed To 2.5 And 8Mm By Changingthe Nail Blades Castor Wheels, , Complete Set , 3500Rpm, Made In Japan Collar Turn And Block Cuff Blocking Automatic Snap Fastner With Feeder ( Pneuamtic ) Gle Needle Double Chain Stitch Machine With Puller , Complete Saddle Stitch , Complete Set Auto Lock Stitch Pocket Welting Machine, For Double Welt And Single Welt , Made In Germany Fixed Needle Bar, For Straight Pockets, Suited With Optional Items For Trouser Manufacturing. Basic Equipment: Brother Original Sewing Head B8422-403 Sewing Head With Fix Needle Bar - Double Welt &-Single Pneumatic Thread Trimmer , - Direct Drive, Alternating Current 220 V, 50-60 Hz Microprocessor Control Box Free Programmable With Liquid Crystal Display And Monitor , - Main Clamp Feed Through Regulate Step Motor And Automatic Variable Length Adjustment For 20-200 Mm - Separate Lowering Of Feeding Clamps Programmable - Reduced Cycle Time Of The Machine Through A Higher Clamp Speed - High Precision Mitre Cutting Of The Machine Through Programmable Mitre Knife Location Regulate Through Step Motor. - Quick Adjustment Of The Mitre Knife Programmable In Control; 0, 1 Mm Steps By 10 Mm Adjustment Length. - Sideways Mitre Knife Adjustment By Eccentric - Mitre Knife Holder With Adjustable Cut Width , - Sewing Through Front - And End Tack Or Stitch Condense Programmable, - Pocket Pouch Clamp For Loading Pocket Pouches - 5 Line Laser Pluggable ( Separate Programmable ) - Piece Counter , - Airgun With Hose , - Top Thread Monitor Model Number -F2130-Printer Width Printing Technology Print Speed Paper Handling Connectivity Power And Operating Requirements Printer Dimensions Printhead Nole Configuration Maximum Resolution Production ( 2 Pass ) Production ( 4 Pass ) Production ( 6 Pass ) Production ( 8 Pass ) Paper Handling Printable Area Media Width Media Thickness Control Panel Printer Interfaces Printer Languages Memory Software Power Requirements Power Consumption Recommended Operating Temperature & Humidity Dimensions Weight Ac 100-120V Ac200-240V 50 / 60H Operating: Approx. 570W; Ready: Approx. 340 W; Sleep: Approx. 14 W; Power Off: Approx. 1.0 W Operating: 15°C To 35°C, Storage: -20°C To 60°C 2, 620 X 934 X 1, 332 Mm ( Wxdxh ) 290Kg ( Without Ink ) Operating: Approx. 600W; Ready: Approx. 380 W; Sleep: Approx. 14 W; Power Off: Approx. 1.0 W Hi-Speed Usb, 100Base-Tx 1000Base-T Standard: Esc / P Raster 512Mb Main + 128Mb Network Bundled In Cd ( Windows Only ) : Cd Installer, Epson Communication Driver, Epson Manual Launcher, Operators Guide, General Information, Epson Control Dashboard, Epsonnet Setup, Epsonnet Config, Epsonnet Print, Software Updater, Dvd ( Epson Edge Print Bundle Sku Only ) Epson Edge Print, Epson Control Dashboard, Epson Communication Driver Web Delivery ( Mac And Windows ) : Windows And Mac: Cd Installer, Epson Communication Driver, Epson Manual Launcher, Operators Guide, General Information, Epson Control Dashboard, Epsonnet Setup, Epsonnet Config, Epsonnet Print, Software Updater, Lfp Accounting Tool Rear Roll Feed ( 2” / 3” Core With Max 250Mm Diameter And Up To 45Kg ) ; Auto Take- Up Reel Max Printing Width: 1615.6Mm; Side Margin: 5Mm Both Sides, 10Mm With Media Holding Guides 300.0 Mm ( 11.8” ) - 1625.6 Mm ( 64” ) Up To 1 Mm 2.7” Colour Lcd Dual Precisioncore™ Tfp® Printhead 360 Noles X Channels X 2 Head 720X1440 Dpi Up To 60.1 M2 / H 720 X 720 Dpi ) Up To 29.9 M2 / H ( 720 X 720 Dpi ) Up To 20.7 M2 / H ( 720 X 1440 Dpi ) Up To 15.6 M2 / H ( 720 X 1440 Dpi ) Up To 62 M2 / H ( 360 X 720 Dpi ) Up To 32.1 M2 H ( 720 X 720 Dpi ) Up To 21.9 M2 / H ( 720 X 720 Dpi ) Up To 15.8 M2 / H ( 720 X 720 Dpi ) 360 Noles X 5 Channels X 2 Head 64” Sc-F9430 ( C11cj00402 ) Sc-F9430h C11ch99402 ) Sc- F9430 ( C11cj00402 ) Weight: 290Kg Without Ink ) Sc-F9430h ( C11ch99402 ) Weight: 290Kg Without Ink ) Supplies & Optional Accessories Maintenance Kit C13s210063 Head Cleaning Set C13s210051 Waste Ink Bottle C13t724000 Cleaning Stick C13s090013 Clean Room Wiper C13s090016 Ink System Ink Type Colours Ink Capacity Epson Ultrachrome™ Ds Dye- Sublimation Ink 4 Colours - Cyan, Magenta, Yellow, High Density Black Cyan, Magenta, Yellow, High Density Black: 1100Ml Ink Pouch Fluorescent Yellow, Fluorescent Pink: 1000Ml Ink Pouch Epson Ultrachrome™ Ds6 Dye- Sublimation Ink 6 Colours - Cyan, Fusion Press -Fusing Press ( Made In Italy ) : Special Calender For Pieces Or Continuous Fabrics, Used For : • Transfer Printing • Direct Inks Reactivation • Thermosetting - Heatsetting Versatile And Polyvalent Calender, Developed For Transfer Printing Of All The Follows Work Conditions, According To Required Options: • Printing Paper In Roll And Material To Be Printed In Roll • Printing Paper In Roll And Material To Be Printed In Pieces • Printing Paper In Sheets And Material To Be Printed In Pieces 1. Characteristics Of Printing Cylinder: 1.1. Diameter : 200 Mm ( 7, 87“ ) . 1.2. Width: 1.800 Mm ( 70, 87“ ) . 1.3. Working Width: 1.500 Mm ( 59, 06“ ) / 1.600 Mm ( 62, 99“ ) . 2. Heating System And Temperature Control: 2.1. The Cylinder Is Heated By One Resistor ( Heating Element ) In A Vacuum Sealed Oil Bath, In Complete Absence Of Air And Pressure. Monti Antonio S.P.A System. 2.2.The Temperature Of The Cylinder Is Set By The Touch Screen And Regulated By An Electronic Card. The Temperature Controls Equipped With Temperature Alarm System And A Limitation System Of Maximum Temperature ( 230 °C ) . 3. Tension Controls: 3.1. Tension Control For Printing Material In Roll: Entry: Brake With Manual Adjustment Exit: Winding With Pneumatic Device 3.2. Tension Control For Printing Paper In Roll: Entry: Disk Brake With Manual Adjustment Exit: Winding With Pneumatic Device 3.3. Tension Control For Protection Paper: Entry: Disk Brake With Manual Adjustment Exit: Winding With Pneumatic Device 4. Other Devices Into Machine: 4.1. Short Front Working Table, 800 Mm 4.2. Single Motor 4.3. Nomex Felt With Manual Tension Adjustment System And Automatic Felt-Centering Device All Data And Technical Features Are Purely Indicative And Subjected To Changes Without Prior Notice Model 180 T 4.4. Incorporated System Of Felt Protection In Case Of Black Out And / Or Compressed Air Lack 5. Technical Data : 5.1. Installed Power: 10 Kw / H 5.2 Determining The Fabric Yield In G / M2 ( Gsm ) Accurately. Suitable For Woven, Non-Woven And Knitted Fabrics. Sturdy High Grade Mild Steel Construction. Manually Operated, Fixed Diameter, Monoybody Aluminum Alloy Structure With Controlled Mass. Specially Designed Blade Mechanism For Rapid And Accurate Cutting. No Additional Rubber Pad And Cutting Blade Arrangement For Longer Life Usage. Suitable For Cutting Any Type Of Material Including Film, Form, Carpet, Paper And Leather. T E C H N I C A L D A T A Cutting Sie : Φ 112.82 Mm ( 4.44 Inch ) Accuracy : ± 0.2 Mm Cutting Depth : 10 Mm Cutting / Specimen Area : 100 Cm2 ( 1 / 100Th Of A Square Meter ) Cutter Life : Maximum 50000 Stokes Aaplicable Standard ( S ) -Lab Testing Machine S Shrinkage Measuring Template :Measure The Dimensional Changes In Fabrics After Laundering, Dry-Cleaning Etc., Ergonomically Designed And Direct Measurement Of Dimensional Change ( Shrinkage & Stretch % ) For All Types Of Fabrics. Template And Scale Made Up Of Transparent Polymer Plate To Apply Standard Pressure On Test Specimen. Calibrated Scale To Check The Shrinkage Directly Up To 15%. Two Fine Tipped Black And Blue Ohp Markers For Accurately Marking On The Dark Colored Fabrics. T E C H N I C A L D A T A Capacity : Up To 15 % ( Shrinkage And Stretch % ) Template Length : 250, 350 & 500 Mm ( Slot To Slot ) Scale Distance : 250, 350 & 500 Mm ( Slot To Slot ) Applicable Standard ( S ) : Aattc 135 / 150 / 160 / 179, Iso 3759 And Bs 4931 Physical Dimensions : Sie ( Wdh ) : 600 X 600 X 6 Mm Weight : 2.5 Kg Digital Bursting Strength -70Kg / Cm2to Determine The Bursting Strength Of All Kind Of Fabrics, Papers And Boards. Diaphragm Bursting Method; Motoried Hydraulic System With Constant Pumping Rate. Thin Diaphragm For Low Bursting Strength Measurement. High Precision Digital Read-Out In Kg / Cm2 & Psi. User Friendly Menu Settings With Single Push Button Switch Operation. Separate Testing Functions For Fabric, Carton And Foil Sheets. In-Built Tare Pressure ( Diaphragm Correction ) Program Ergonomically Designed With Modern Aesthetics. T E C H N I C A L D A T A Capacity : 0.5 To 70 Kg / Cm2 ( 7.0 To 1000 Psi ) Range : 2.5 To 70 Kg / Cm2 ( 35 To 1000 Psi ) With Standard Diaphragm 0.5 To 10 Kg / Cm2 ( 7.0 To 140 Psi ) With Thin Diaphragm Accuracy : ± 1 % Fs, Readability : 0.01 Kg / Cm2 – Below 10 Kg / Cm2 0.1 Kg / Cm2 – Above 10 Kg / Cm2 Display : Digital Alpha-Numeric Lcd Display Clamp Opening 30.0 Mm Throat Depth : 100 Mm Test Diameter : Ø 30.5 Mm Test Fluid : Glycerin; Filling Capacity: 95 Ml Test Specimen Sie : 100 X 100 Mm ( Minimum ) Hydraulic Flow Rate : 95 ± 5 Ml / Min Drive Motor : 0.27 Kw, 1440 Rpm Single Phase Ac Induction Motor Power Supply : Single Phase 220Vac @ 50H Consumption : 300 Watts Applicable Standard ( S ) : Astm D3786 ( Hydraulic And Work Factor Of Fabrics. Ergonomically Design With Modern Sophisticated Look. Elmendorf Method, Supplied With Calibration Weight And Augmenting Mass To Test Up To 6400 Grams. Fabric Below 320 Gf Can Be Tested With Multiple Specimens. Tearing Force Can Be Calculated With Simple Calculations. Accurate Slit Cutting Blade With The Special Care To Safety Of The Operators. T E C H N I C A L D A T A Capacity : Up To 100 % Of Fsr ( Full Scale Readings ) Measuring Range : 20 To 80 % Of Fsr. Accuracy : ± 1% Of Fsr Download Pressure : 1600 Gf ( Without Augmenting Weight ) 3200 Gf ( With Augmenting Weight “A” ) 6400 Gf ( With Augmenting Weight “A+B” ) Tearing Distance : 43.0 ± 0.15 Mm Slit Sie : 20 Mm ± 0.2 Mm Distance Between Clamps : 2.5 Mm ± 0.3 Mm Specimen Template Side : Fabric Stretch And Recovery Meter : Determine The Stretch And Recovery ( Elasticity ) Of Textile Fabrics ( Knitted And Woven ) , Where Extension At Break Is Not Required. Table Top; Simple And Economical; Easy To Use Manual Operation. Self- Aligning Flat Faced Stainless Steel Clamps With Pu Grips For Better Gripping. Sturdy Loading Frame Fitted With Screw Tensioning Device. Calibrated Dead Weights For Accurate Loading; Specimen Template For Quick Sample Preparation. T E C H N I C A L D A T A Load Application : By Hanging Calibrated Dead Weight ( S ) Loading Range : 1 To 5 Kg ± 2% ( Applied In Steps Of 1 Kg ) Test Length : 1 ) 200 Mm For Woven Fabrics 2 ) 75 Mm For Knitted Fabrics Extension Range : 50 % For Woven Fabrics And 300 % For Knitted Fabrics Specimen Clamping Area : 75 X 10 Mm Applicable Standard ( S ) : Bs 4294 Physical Dimensions : Sie ( Wdh ) : 650 X 150 X 150 Mm Weight : 15 Kg Well As Pilling Resistance Of All Kind Of Fabrics. Ergonomically Designed With Modern Aesthetics And Accurate Lissajous Figure. Martindale Abrasion Method With 4 Working Heads And Individual Selectable Working Pressure Of 3 / 9 / 12 Kpa. Grading The Specimen Against Photographic Standards For Woven And Knitted Fabrics. Digital Controls And Unique Design Supplied With Specimen Cutter For Ease Of Operation. Supplied With All Accessories Including Two Sample Cutters Φ 140 Mm & Φ 38 Mm With Spare Blades & Cutting Materials To Make Sample Conveniently. T E C H N I C A L D A T A Capacity : One To Four Specimen At A Time Measuring Range : 99999 Times ( Continuous Cycle ) Working Pressure : 3 Kpa, 9 Kpa & 12 Kpa Rotational Speed Of Outer Pegs : 47.5 ± 2.5 Rpm Total Stroke Of Outer And Inner Pegs : 1 ) 60.5 ± 0.5 Mm ( Abrasion ) 2 ) 24.0 ± 0.5 Mm ( Pilling ) Circumferential Parallelism : ± 0.05 Mm Of Sample Holders To Abrading Tables Power Supply : Single Phase 220Vac @ 50H; Ici Pilling Tester -2 Boxes -Features : Determine The Tendency To Form Pills. Test Specimens Taken From The Fabric Sample Are Rubbed Against Each Other Under Controlled Conditions. Grading The Specimen Against Photographic Standards For Woven And Knitted Fabrics. Ici Pillbox To Replicate Pilling On Fabric. State-Of-Art Microcomputer Solid-State Controlled Circuitry With User-Friendly Menu Driven Operating System. Latest Engineering Components For The Easy And Maintenance Free Operation. Specially Designed Two Wooden Pilling Stations For Better Efficiency Of Work. Alphanumeric Lcd Display Screen With Backylight Illumination. Inching Facility To Easily Assess For Sampling. T E C H N I C A L D A T A Pilling Boxes Sie : 235 X 235 X 235 Mm ( As Per Standard ) Cork Liner Thickness : 3.2 Mm ( As Per Standard ) Boxes Rotation Speed : 60 ± 2 Rpm ( As Per Standard ) Test Specimen Sie : 125 X 125 Mm Rubber Tube Sie : Length : 140 ± 0.5 Mm; Diameter : 31.5 ± 0.5 Mm Wall Thickness : 3.2 ± 0.5 Mm; Weight : 52.25 ± 0.5 Gram Control System : Microcomputer Based Solid-State Control Circuitry Power Supply : Single Phase 220Vac @ 50H; Consumption : 100 Watts Applicable Standard ( S ) : Bs En Iso 12945- 1 ( Part-1 ) , Bs 5811 & Is 10971 Physical Dimensions : Sie ( Wdh ) : 860 X 790 880 Mm Weight : 50 Kg Digital Thickness Gauge :Determine The Thickness Of Woven, Knitted, Coated Narrow Fabrics, Tapes, Ribbons, Braids, Films, Glass Fabrics, Glass Tapes. An Inexpensive Model With Ease Of Operation. Range : 0 - 10 With 10 Micron Resolution. Portable & Handy To Carry Anywhere. Supplied With Two Pressure Foot Of Different Sie For Different Type Of Fabrics. A Standard Pressure Weight Is Provided With The Instruments For Accurate Result. Digital Display For Measuring Thickness In Millimeters. T E C H N I C A L D A T A Measuring Range : 0.010 To 10.00 Mm Measuring Accuracy : ± 0.01 Mm ( Or ) ± 10 Microns Readability : 0.01 Mm Diameter Of Anvil : Top : 75 ± 0.2 Mm Pressure Foot : A ) Φ 28.7 Mm B ) Φ 25.0 Mm Pressure Weight : A ) 1 Kpa B ) 5 Kpa C ) 10 Kpa D ) 4.14 Kpa Applicable Standard ( S ) : Astm D1777, Bs 2544 / 3424 / 4051 / 4098 / 4223 / 29073, Flammability Tester -45°Specialied Equipment To Determine Flammability Of The Fabrics. Latest Ergonomically Design With Modern Aesthetics. Stainless Steel Construction, Glass Observation Window And Digital Timing Control. Fine Gas Control System To Regulate The Flame Length. Movable Sample Mounting Mechanism To Adjust The Sample As Per Standards. Specially Designed Digital Re-Settable Timer. Refilling Of Gas Container With Mechanical Valve. T E C H N I C A L D A T A Specimen & Template Sie : 150 X 50 Mm Specimen Flame Time : 1 Second ( As Per Standard - To Be Change The Seconds As Per Application ) Flame Height : 16 Mm ( 5 / 8 Inch ) Height Adjustment Of Flame : 19 Mm ( 3 / 4 Inch ) Burner Specimen Distance : 8 Mm ( 5 / 16 Inch ) Digital Timer : 0 - 99.9 Sec; Least Count : 0.1 Second Testing Time : Depends Upon To The Test Specimen / Procedure Sample Holder Sie : 165 X 50 Mm Applicable Standards : Astm D1230 And 16 Cfr Part 1610 Power Supply : Single Phase 220Vac @ 50H Physical Dimensions : Sie ( Wdh ) : 330 X 230 X 650 Mm Weight : 15 Kg ( Accessories Excluded ) Fabrics And The Flame Propagation Rate Onto Vertically Oriented Textiles Materials. Cabinet Fabricated Out Of High Quality Brushed Mild Steel, Glass Observation Window And Back Wall Painted Black For Easy Test Viewing. Specially Designed Two Different Burners And Angle Adjustment ( Vertical, 30° & Horiøontal Position ) With Gas Pilot Light. Counting Timer Automatically Activated At Time Of Flame Impingement. Specimen Holder And Burners Are Dependent On The Test Standard And Must Be Specified. Flame Height 40 ± 2 Mm Adjusted By Mechanical Valve - Flame Height Gauge Included. Gas Container Refillable - With Mechanical Valve. T E C H N I C A L D A T A Specimen & Template Siøe : 300 X 76 Mm ( As Per Standard Astm D6413 ) 200 X 160 Mm ( As Per Standard Bs 5867 ) 560 X 170 Mm ( As Per Standard Bs 5867 ) Flame Time Of The Specimen : 12 Second ( To Be Changed As Per Application ) Flame Height : Maximum 40 ± 2 Mm ( As Per Standard Bs 5867, Astm D6413 & Is 11871 ) Gas Controls System : 1. Electric Solenoid Valve ( Flame Impingement Timer ) 2. Base Valve For Burner Height Adjustment 3. Base Valve For Pilot Light Adjustment Burner Details : 1 ) In Side Diameter : 10 Mm ; 2 ) Height : 76 ± 2 Mm ( Astm D6413 ) 3 ) Type Crease Recovery Tester :Determine The Property Of Textiles To Recover From Crease By Measurement Of The Recovery Angle. Ergonomic Design With Stylish Appearance. 9.63 N ( 980 Gram ) Weight Supplied As Per Iso Standard. 4.90 N ( 500 Gram ) Weight Supplied As Per Aatcc Standard. Calibrated Dial Graduated In Degree For Accurate Recovery Angle. This Instrument Meets The Specifications Of Both Iso & Aatcc Standards. T E C H N I C A L D A T A Creasing Load : 980 Gram ( 9.63 N ) As Per Iso Standard 500 Gram ( 4.90 N ) As Per Aatcc Standard Angle Measurement : On A Sticker Circular Scale Graduated In 1 Degree. Scale Range : 10° - 180°; Least Count : 1° Scale Disc Diameter : 145 Mm Specimen Template Siøe : 40 X 15 Mm Applicable Standard ( S ) : Iso 2313, Aatcc 66, Bs 3086 & Is 4681 Physical Dimensions : Siøe ( Wdh ) : 240 × 140 × 190 Mm Weight : 20 Kg Spray Rating Tester : Determine The Water Repellency Or Surface Wetting Resistance Of Fabrics. Latest Economic Design With Modern Esthetics. Stainless Steel Spray Noøøle For Rust Free, Long Life & Durability. Specimen Holder Is Fixed At 45° To The Specification Of Aatcc Tandard. Appearance Of The Specimen Is Compared Against Photographic Chart. Complete With All Accessories Including 500Ml Beaker. T E C H N I C A L D A T A Test Specimen Siøe : 180 X 180 Mm Square Spray Noøøle Siøe : 1 ) Height : 49 ± 0.38 Mm 2 ) Width : 32.5 ± 0.5 Mm 3 ) Inner Diameter : 4.5 Mm 4 ) Outer Diameter : 8.8 Mm Spray Noøøle : Converse Face With 19 Holes ( Center-1, First Circle-6, Second Circle-12 ) Water Spray Rate : 250 Ml In 25 To 30 Seconds Test Specimen Position : Mounted On A Ring And Placed At An Angle Of 45° Distance Between Center Of Spray : 150 Mm ± 2 Mm Noøøle And Center Of The Specimen Holder Diameter : 150 Mm ± 5 Mm Plastic Funnel Diameter : 150 Mm ± 5 Mm Height Of The Funnel With Noøøle : 200 Mm ±10 Mm Applicable Standard ( S ) : Aatcc 22, Iso 4920, Bs 3702 And Is 390 Physical Dimensions : Siøe ( Wdh ) : 430 X 310 X 480 Mm Weight : 3.5 Kg Advanced Crock Meter-Motorised :Determine The Color Fastness Of Textiles ( Irrespective Of Their Composition Like Wool, Cotton, Linen, Silk, Man-Made Fibers, Etc. ) Against Rubbing Under Wet Or Dry Condition. Motoriøed And Precision-Engineered Mechanism For Smooth And Accurate Operation. Pre-Settable Digital Counter For Strokes 5 To 999 With Auto Stop. Electronically Controlled System To Minimise Operator Variation. Two Types Of Specimen Holders For Rapid Sample Mounting And Repeatability Of Results. Enhanced Testing Provision For Testing Of Yarns, Carpets And Floor Coverings. Designed To Enable Extra Weights And Movement For Nonstandard Tests. T E C H N I C A L D A T A Rubbing Fingers : 1 ) Finger I - Round Φ 16.0 ± 0.1 Mm ; 2 ) Finger Ii - Round Φ 25.0 ± 0.1 Mm 3 ) Finger Iii - Rectangular ( Φ19.0 X 25.4 ) ± 0.1 Mm 4 ) Finger Iv - Round Φ 25.0 ± 0.1 Mm On Φ 32.0 ± 0.1 Mm Finger Movement : 1 ) 104 ± 3 Mm At Position 2 ) 100 ± 2 Mm At Position : 3 ) 76 ± 1 Mm At Position 4 ) 51 ± 1 Mm At Position Download Force : 1 ) 9N ± 5% ( 917.74 Gram ) 2 ) 22N ± 5% ( 2243.38 Gram ) Crocking Cloth Siøe : 1 ) 5 Cm X 5 Cm 2 ) 7.5 Cm X 7.5 Cm Test Specimen Siøe : 25 Cm X 5 Cm For All Fabrics And No Specific Siøe For Multiple Strands Of Yarns Preprogrammable Range : 5 To 999 Strokes Power Supply : Single Phase 220Vac @ 50Hø; Consumption : 50 Watts Applicable Standard ( S ) : Aatcc 8, Aatcc 165, Bs 1006, Bs 4655 & Iso 105 Physical Dimensions : Siøe ( Wdh ) : 300 X 700 X 500 Mm; Weight : 20 Kg Textile Materials To Decide The Commercial Mass And To Study The Effect Of Moisture On Textile Properties. Digital Controlled And Stainless Steel Interior Construction – Compact Model. Removable Tray System With Two Shelves. Easily Accessible Ventilation Port With Adjustable Opening. Equipped With Laboratory Standard Forced Air Circulating Fan For Even Temperature Distribution Inside The Chamber. Suitable For Other Oven- Dry Laboratory Applications. T E C H N I C A L D A T A Usable Volume : 120 Liters ( 450 Mm X 450 Mm X 600 Mm ) Temperature Range : Ambient To 180° C Accuracy : ± 1° C Heater Capacity : 1200 Watts Power Supply : Single Phase 220Vac @ 50 Hø Consumption : 1500 Watts Applicable Standard ( S ) : Perspiration Tester : Determine The Color Fastness Of Textile Against Water And Perspiration ( Applicable To Dyed, Printed Or Otherwise Colored Textile Fibers, Yarns And Fabric Of All Kinds ) . Sturdy High Grade Stainless Steel Construction. Dual Plates, Compensating Springs, Loading Weights Are Made As Per Standard Requirement. Easy, Comfort And Focal Point Placement Of Loading Weights Ensures Even Pressure Distribution Throughout The Sample. T E C H N I C A L D A T A Capacity : 21 Samples Loading Weight “A” ( Aatcc ) : 3.63 Kg ( 8.0 Lb ) Additional Weight “B” ( For Iso ) : 0.56 Kg ( A+B = 12.5 Kpa On Sample ) Weight Of Dual Plate Assembly : 0.91 Kg ( 2.0 Lb ) Siøe Of Acrylic Separator Plate : 60 X 115 X 1.5 Mm Test Specimen Siøe : 1 ) ( 60 X 60 ) ± 20 Mm For Aatcc 2 ) 40 X 100 Mm For Iso & Bs Multifibre Test Fabric Siøe : 1 ) ( 60 X 60 ) ± 20 Mm For Aatcc 2 ) 40 X 100 Sample Conditioning Chamber :Prepare The Test Specimen Under Standard Climatic Conditions For Required Test. Double Walled Construction, With Inner Highygrade Stainless Steel Body. Low Pressure Boiler That Generates Stream For Chamber Humidification. Ambient Condition Such As Temperature 21 / 27 ± 2°C & Humidity 65 ± 5% Can Be Easily Attended. Dynamically Balanced Chamber Circulation With Well Balanced Refrigeration System. Transparent Viewing Window To View The Sample. Light Fitted Inside The Chamber For Viewing The Sample. Caste Wheel At Base For Easy Movement. Three Perforated Trays Supplied With The Equipment To Keep The Samples Properly Inside The Chamber. T E C H N I C A L D A T A Chamber Siøe : 418 X 440 X 825 Mm Capacity : 6.0 Cubic Feet / 150 Liters. Temperature Range : 5 To 60 ± 1° C Humidity : 40 – 90 ± 3 % Standard Temperature For Textile : 21 ± 2°C ( Or ) 27 ± 2°C Standard Humidity For Textile : 65 ± 5 % Power Supply : Single Phase 220Vac @ 50Hø; Consumption : 3000 Watts Applicable Standard ( S ) : Astm D1776 Physical Dimensions : Siøe ( Wdh ) : 630 × 900 × 1500 Mm Weight : 200 Kg Analog Fabric Stiffness Tester For Circular Bend : Determine The Stiffness Of Fabrics In Compliance With Astm Circular Bend Test Method. Automatic Operation With Pneumatic Control Ensures Accurate Operation. Table Top Design; Dial Gauge With Peak-Hold Facility. Dual Test Button System For Ergonomic Comfort. T E C H N I C A L D A T A Capacity : 30 Kgf ( Resolution250 Gf ) Plunger Diameter : 25.4 ( ± 0.1 ) Mm Platform : 102.0 X 102.0 X 6.0 ( ± 0.5 ) Mm Orifice Diameter : 38.1 ( ± 0.05 ) Mm Stroke Length : 57.0 ( ± 0.5 ) Mm Test Specimen Siøe : 204 Mm X 102 Mm Plunger Actuator : Pneumatic Input Pressure : 6 Bar ( 80 Psi / 600 Kpa ) ±10% Set Pressure : 3.24 Bar ( 47Psi / 324 Kpa ) Display : Analogue Dial Gage Applicable Standard ( S ) : Astm D4032 / 1338, Bs 3356 & Is 6490 Physical Dimensions : Siøe ( Wdh ) : 450 X 350 X 700 Mm Weight : 15 Kg Color Matching Cabinet -Metal Body : Visual Assessment Of Colors In Munshell Grey Cabin Under Standard Lighting Conditions. Economic Model Fitted With Rocker Switches And Hour Meter. Light Weight Sheet Metal Construction And Supplied Along With Angled Viewing Stand. Used With Electronic Ballasts For Instant Start & Power Saving. Available Light Source: D65, Tl-84, Inc- A, Uvb And Cwf. T E C H N I C A L D A T A Illuminant ( Source ) : 1 ) D65 ( Artificial Daylight; Correlated Color Temperature 6500K ) 2 ) Uvb ( Ultraviolet Black Light ) 3 ) Tl 84 ( Triphosphor Fluorescent Lamp; Correlated Color Temperature 4000K ) 4 ) Cwf ( Cool White Fluorescent Lamp; Correlated Color Temperature 4150K ) 5 ) Inc-A ( Tungsten Filament Light; Correlated Color Temperature 2800K ) Life Time Of The Bulbs : 2000 Hours Length Of The Bulb : 2 Feet Power Supply : Single Phase 220Vac @ 50Hø; Consumption : 20 Watts Applicable Standard ( S ) : Astm D1729, Iso 3664, Bs 950 & Din 6173 Physical Dimensions : Siøe ( Wdh ) : 670 × 460 × 540 Mm Weight : 20 Kg ( Capacity 50 Kg ) Technical High Lights The Machines Are Used In The Processing Of Linen & Garments With Water As Medium To Wash. These Machines Are Made Out Of Tested Stainless Steel Of Aisi Grade 304 On The Front Cover & Wetted Parts.The Machine Comes With A Water Level Indicator & A Stainless Steel Chemical Hopper. Heating Of The Wash Load Is Via Direct Steam Injection, Or Via Stainless Steel Electric Heating Elements. The Chemical Enter The Wash Cycle In The Inner Basket Via A Stainless Steel Chemical Box Fitted On The Side Of The Machine. Technical Specification: Basket Volume ( Ltrs ) : 565 Basket Dept ( Mm ) : 720 Basket Diameter ( Mm ) : 1000 Door Opening ( Mm ) : 670 Motor ( Kw ) : 2.25 Steam Inlet ( Inch ) : 1 Water Inlet ( Inch ) : 1.5 Drain Outlet ( Mm ) : 75 Heater ( Optional ) ( Kw ) : 18 Dimension ( Wxdxh ) ( Mm ) : 1240X1400x1890 Approx Weight ( Kgs ) : 740 ( Capacity 100 Kg ) Technical High Lights The Machines Are Used In The Processing Of Linen & Garments With Water As Medium To Wash. These Machines Are Made Out Of Tested Stainless Steel Of Aisi Grade 304 On The Front Cover & Wetted Parts.The Machine Comes With A Water Level Indicator & A Stainless Steel Chemical Hopper. Heating Of The Wash Load Is Via Direct Steam Injection, Or Via Stainless Steel Electric Heating Elements.The Chemical Enter The Wash Cycle In The Inner Basket Via A Stainless Steel Chemical Box Fitted On The Side Of The Machine. Technical Specification: Basket Volume ( Ltrs ) : 993 Basket Dept ( Mm ) : 850 Basket Diameter ( Mm ) : 1220 Door Opening ( Mm ) : 670 Motor ( Kw ) : 5.625 Steam Inlet ( Inch ) : 1 Water Inlet ( Inch ) : 2 Drain Outlet ( Mm ) : 75 Heater ( Optional ) ( Kw ) : 27 Dimension ( Wxdxh ) 1700X1750x2230 Approx Weight ( Kgs ) : 1100 Hydro Extractor ( Capacity 50 Kg ) Technical High Lights High Capacity, Efficient As Its Less Energy Consumption. Auto Controlled Devices, Timer & Balanced Protection Brake. Overload Display Device And Cover Protector Device Ensures Safety Operation & Extends The Life Span Of Hydro Extractor. Additional Load / Unload Features Make The Operation Very Convenient. A Pneumatic Locking System Enhances Operator Safety By Ensuring The Door Cannot Be Opened While The Basket Is Rotating This Machine Is Manufactured Using A Special Sg Grade Single Frame Casting. Technical Specification: Basket Volume ( Ltrs ) : 209 Basket Dept ( Mm ) : 350 Basket Diameter ( Mm ) : 900 Basket Speed ( Rpm ) : 800 Motor ( Hp ) : 7.5 Drain Size ( Mm ) : 76.2 Door Opening ( Mm ) : 670 Dimension ( Wxdxh ) ( Mm ) : 1800X1400x960 Approx Weight ( Kgs ) : 1156-Tumble Driers- ( Capacity 30 Kg ) Technical High Lights The Special Radiator / Heat Exchanger Design & Efficient Blower System Makes The Drying Time Of This Ramsons Dryer The Best In Its Class. The Stainless Steel Inner Basket Is Programmable On Time For Forward & Reverse Rotations To Prevent Garments From Entangling& A Large Glass Door Is Provided For Ease Of Loading Unloading Linen / Garments. Programmable Micro Processor Control System Comes Standard With This Machine. Emergency Stop Buttons And A Safety Limit Switch Is Pre Installed To Ensure Safety Of The Operator. High Load Capacity Ratings, Self Cleaning Lint Screen & Other Design Features Makes This Dryer A Space & Energy Saving & Guarantees Faster Drying Time. Technical Specification: Basket Volume ( Ltrs ) : 613 Basket Dept ( Mm ) : 830 Basket Diameter ( Mm ) : 970 Door Opening ( Mm ) : 750 Motor ( Hp ) : 2Air Outlet ( Mm ) : 150X200 Heater ( Optional ) Kw ) : 24 Dimension ( Wxdxh ) ( Mm ) : 1050X1320x1870approx Weight ( Kgs ) : 550 Iner Basket Ss 304-Tumble Driers- ( Capacity 60 Kg ) Technical High Lights The Special Radiator / Heat Exchanger Design & Efficient Blower System Makes The Drying Time Of This Ramsons Dryer The Best In Its Class. The Stainless Steel Inner Basket Is Programmable On Time For Forward & Reverse Rotations To Prevent Garments From Entangling& A Large Glass Door Is Provided For Ease Of Stain Removin G Machine With Compres Sor Thread Sucking Machine With Sensor Electri C Steam Generat Ors Veit Ironing Vaccum Ironing Table With Buck With Tube Light Trey Fitting
BRR : 9468305
Tender For Rates For Material/Equipment Regarding Medical Gas Pile Line System And Modular Operation Theatre For Estimate Preparation. - Rates for Material/Equipmentregarding Medical Gas Pile Line System and Modular Operation Theatre for estimate preparation. 2 Medical Gas Pipe Line (Part-A) 3 Oxygen Manifold 4 SITC of 10 + 10 size main manifold complete with middle frame with chain for individual cylinder along with Non Return Valve for every cylinder.All header racks and cylinder tailpipes should be 230 bar rated. Cylinder header racks for oxygen service shall be provided with connections for bull nose cylinder connections. Cylinder racks shall be manufactured from powder coated steel and shall be designed to securely support cylinders of varying diameters. Tailpipes shall have gas specific connections to the manifold header with threaded connections. Manifold header racks shall incorporate hard-seat, polymer-free non-return integral with each cylinder connection point to maintain system in the event of tailpipe fracture and prevent backflow of gas into the high pressure cylinders. as per specification (Mandatory submission--> 100% technical complaince sheet should be submitted with the technical bid from original manufacturer.)Make- Altos/Aktiv or Equivalent 5 Certifications: ISO 13485:2016,ISO 9001:2015, CE 6 Fully Automatic Oxygen Gas Control System 7 SITC of Fully Automatic Oxygen Control Panel for main Oxygen Manifold having constant flow output of over 2100 LPM or more at 55 to 60 psig Pressure. A test certificate shall be provided with each system detailing the results of the factory tests ,It should have halogen polymers free. It should have Digital 3.5’ colorful display. It should have Integrated & protected test point. Central regulators panel with cylinder headers each side. It should have headers which shall be complete with gas specific cylinder tailpipes. Pre-wired for alarm connection to BMS outputs. All components degreased for oxygen use .Average gas consumption indication (for not liquefied gases). Remaining gas volume indication (for not liquefied gases). It should have general maintenance indicator. It should have Pressure transmitters monitor both banks of cylinders & as per specification. (Mandatory submission--> 100% technical complaince sheet should be submitted with the technical bid from original manufacturer.)Make- Altos/Aktiv or Equivalent 8 Oxygen Flowmeter with Humidifier 9 Essentia medical gas flowmeters are designed to measure and regulate flow.These are calibrated to specific gas & flow range. Oxygen flowmeter is intended for use with various delivery system when bubble/ micro bubble humidifier is attached downstream. These flowmeters are widely used in home care, health centers, district/ general/ regional hospitals, tertiary care, emergency vehicles etc. for administration of supplemental oxygen through nasal cannula, simple face mask,partial rebreathing mask, non re-breather mask, resuscitation mask etc. A passive process to humidify dry therapeutic gas (Category 3 Humidification) Micro Bubble Humidifier for Respiratory Therapy Patient connection port : Tapered hose barb suitable for 6 mm inner diameter plastic tubingMicro bubbles through humidifier for efficient humidificationPossible to integrate into an oxygen concentrator, sleep apnoea therapy equipmentOptimal RH achievable at various flow settingsAutoclavable at 121°C (249.8°F) for 5 minutes (Minimum 5 autoclave cycles)Over pressure safety valveNon-heated and reusableInlet connection port : DISS female adapter with chrome plated Brass nut embedded in ABS for hand-tighteningFlow : Up to 15 lpm @ 4 bar (58 psi)Construction material: Polycarbonate - shatter resistantCapacity - 240ml at max water level (Jar 450ml)Make- Altos/Aktiv or Equivalent 10 Emergency Oxygen Manifold 11 The oxygen cylinder manifold should comprise of two cylinder Banks which can accommodate 6 cylinders in each Bank (means 6+6) complete with copper tail pipes with bull nose fittings of RH External threading suitable for cylinder valves (Oxygen service) and Cylinder support system. Manifold should be suitable to withstand a pressure of 140 Kg/cm2, along with high pressure copper annealed tail pipes with Brass adapter suitable for Oxygen Cylinders and manifold. Top frame comprising of high pressure copper pipes of size 1/2I.D. x 15swg with high pressure brass fittings made of high tensile brass and connections through non- return valves. High pressure copper tail pipes, made of high pressure copper pipe of size 1/4I.D. x 15 swg.The middle and bottom frame to be provided to fit both round and flat bottom cylinders safely. The manifold should be tested (hydraulically) at 250kg / cm sq. The copper tail pipes are fitted to the individual non return valves of the cylinder manifold for easy removal of cylinders without disturbance to system operation. Make- Altos/Aktivor Equivalent 12 Fully Automatic Oxygen Gas Control System 13 SITC of Fully Automatic Oxygen Control Panel for main Oxygen Manifold having constant flow output of over 2100 LPM or more at 55 to 60 psig Pressure. A test certificate shall be provided with each system detailing the results of the factory tests ,It should have halogen polymers free. It should have Digital 3.5’ colorful display. It should have Integrated & protected test point. Central regulators panel with cylinder headers each side. It should have headers which shall be complete with gas specific cylinder tailpipes. Pre-wired for alarm connection to BMS outputs. All components degreased for oxygen use .Average gas consumption indication (for not liquefied gases). Remaining gas volume indication (for not liquefied gases). It should have general maintenance indicator. It should have Pressure transmitters monitor both banks of cylinders & as per specification. (Mandatory submission--> 100% technical complaince sheet should be submitted with the technical bid from original manufacturer.)Make-Altos/Aktiv or Equivalent 14 MEDICAL NITROUS OXIDE SYSTEM 15 Nitrous Oxide Manifold 16 SITC of 4 + 4 size main manifold complete with middle frame with chain for individual cylinder along with Non Return Valve for every cylinder.All header racks and cylinder tailpipes should be 230 bar rated. Cylinder header racks for oxygen service shall be provided with connections for bull nose cylinder connections. Cylinder racks shall be manufactured from powder coated steel and shall be designed to securely support cylinders of varying diameters. Tailpipes shall have gas specific connections to the manifold header with threaded connections. Manifold header racks shall incorporate hard-seat, polymer-free non-return integral with each cylinder connection point to maintain system in the event of tailpipe fracture and prevent backflow of gas into the high pressure cylinders.. as per specification.(Mandatory submission--> 100% technical complaince sheet should be submitted with the technical bid from original manufacturer.)Make-Altos/Aktiv or Equivalent 17 Fully Automatic Nitrous Oxide Gas Control System 18 SITC of Fully Automatic Control Panel for Nitrous Oxide having constant flow output of over 500 LPM at 4.2 Bar Pressure. Digital Fully Automatic Control Panel. It should fully complies and meets with the requirements of the NFPA-99 standards. It should be UL or ETL Listed. The manifold control panel shall consist of two bank regulators (dome bias) used to reduce the cylinder pressure to the two line regulators which in turn controls the final line pressure. The manifold has an intermediate and line relief valve that is internally connected to a common vent port, terminating into a 1/2 FNPT pipe. It should be fully automatic type and shall switch from “Bank in Use” to “Reserve Bank” without fluctuation in the final line pressure. After the switchover, the “Reserve Bank” shall then become the “Bank in Use” and the “Bank in Use” shall become the “Reserve Bank.” The control panel includes a line gauge, two bank gauges and incorporates six LED’s: two green for “Bank in Use,” two yellow for “Bank Ready” and two red for “Bank Empty” on the front of the cabinet. Input power to the manifolds is 110 to 240 VAC, 50-60 Hz& as per specification. (Mandatory submission--> 100% technical complaince sheet should be submitted with the technical bid from original manufacturer.)Make- Altos/Aktiv or Equivalent 19 Emergency N2O System 20 SITC of 2 Cylinder Emergency Nitrous Oxide manifold with All header racks and cylinder tailpipes should be 230 bar rated. Cylinder header racks for oxygen service shall be provided with connections for bull nose cylinder connections. Cylinder racks shall be manufactured from powder coated steel and shall be designed to securely support cylinders of varying diameters. Tailpipes shall have gas specific connections to the manifold header with threaded connections. Manifold header racks shall incorporate hard-seat, polymer-free non-return integral with each cylinder connection point to maintain system in the event of tailpipe fracture and prevent backflow of gas into the high pressure cylinders using a high flow Preset Pressure Regulator as per specification.(Mandatory submission--> 100% technical complaince sheet should be submitted with the technical bid from original manufacturer.)Make- Altos/Aktiv or Equivalent 21 MEDICAL CARBON DIOXIDE SYSTEM 22 CARBON DIOXIDE SYSTEM 23 The CO2 cylinder manifold should comprise of two cylinder Banks which can accommodate 4 cylinders in each Bank (means 4+4) for cylinder valves conforming to IS 3234 (CO2@ service) complete with copper tail pipes with fittings. Manifold should be suitable to withstand a pressure of 140 Kg/cm2, along with high pressure copper annealed tail pipes with Brass adapter suitable for Nitrous Cylinders and manifold. Top frame comprising of high pressure copper pipes of size 1/2I.D. x 15swg with high pressure brass fittings made of high tensile brass and connections through non- return valves.High pressure copper tail pipes, made of high pressure copper pipe of size 1/4I.D. x 15 swg.The middle and bottom frame to be provided to fit both round and flat bottom cylinders safely. The manifold should be tested (hydraulically) at 250kg / cm sq. The copper tail pipes are fitted to the individual non return valves of the cylinder manifold for easy removal of cylinders without disturbance to system operation. Each manifold should be provided with one terminal header and a NPT connection for the Automatic control panel. Make- Altos/Aktiv or Equivalent 24 Certifications: ISO 13485:2016,ISO 9001:2015, CE 25 Fully Automatic Carbon DioxideGas Control System 26 SITC of Fully Automatic Control Panel for Carbon dioxide having constant flow output of over 500 LPM at 4.2 Bar Pressure. Digital Fully Automatic Control Panel.The manifold control panel shall consist of two bank regulators (dome bias) used to reduce the cylinder pressure to the two line regulators which in turn controls the final line pressure. The manifold has an intermediate and line relief valve that is internally connected to a common vent port, terminating into a 1/2 FNPT pipe. It should be fully automatic type and shall switch from “Bank in Use” to “Reserve Bank” without fluctuation in the final line pressure. After the switchover, the “Reserve Bank” shall then become the “Bank in Use” and the “Bank in Use” shall become the “Reserve Bank.” The control panel includes a line gauge, two bank gauges and incorporates six LED’s: two green for “Bank in Use,” two yellow for “Bank Ready” and two red for “Bank Empty” on the front of the cabinet. Input power to the manifolds is 110 to 240 VAC, 50-60 Hz& as per specification. (Mandatory submission--> 100% technical complaince sheet should be submitted with the technical bid from original manufacturer.)Micro processor controlled switch-over is accomplished automaticallyAutomatically resets itself for next cycle when depleted bank is replenished. No manual resetting requiredDigital pressure indication for accurate readingPressure unit options: bar, psi & kg/cm Status indicatorsPressure Stabilizer for stable discharge pressure & flowVisual & Audible signalDesigned to suit CO2 for gas specific usageOptimized residual gasMake-Altos/Aktiv or Equivalent 27 Emergency CO2 System 28 The Emergency supply manifold shouldbe connected to downstream of the manifold control panel.The assemblyshould consist of 2 (two) cylinders connection supplying a manually adjusted regulator via a common header assembly. The delivery system is isolated from the main system by an isolation valve. Pressure gauges should indicate cylinder and delivery pressure & valves conforming to ISO 13485Make- Altos/Aktiv or Equivalent 29 MEDICAL VACUUM SYSTEM 30 SITC of MEDICAL VACUUM SYSTEM AS PER SPECIFICATION 31 Vacuum Pump : The arrangement should consist of 2 nos. of oil lubricated imported rotary vane vacuum pump. Each vacuum pump should have capacity of 5000 lpm with IEC Motor rating of minimum 10 HP @ 50 Hz or above. Vacuum pumps shall comprise of air cooled, oil lubricated rotary vane vacuum pumps suitable for both continuous and frequent start / stop operation at inlet vacuum vessels between 525 mm Hg and 700 mm Hg. The ultimate vacuum of pump shall be 0.1 mbar with gas ballast valve closed. The Vacuum Pump should be air cooled and oil lubricated rotary vane vacuum pumps designed for use in the field of high quality vacuum. It should be a robust construction, reliable operation, highly resilient carbon composite fiber vanes, Gas ballast valve. The pump should be having a 4 barriers system that avoids any oil leaks by doubling the 2 lip / shaft seals. Pump vanes shall be lubricated by a fully re-circulated and filtered lubricant supply. Also Pump design should include a lubricant separation system integral to the pump exhaust box consisting of no less than four stages of internally installed lubricant and smoke eliminators through which the exhaust gas stream must pass. This system shall consist of bulk separation, lubricant mist elimination, smoke elimination, synthetic lubricant baffle, and shall be capable of removing 99.9 percent of all lubricant and smoke particles from the exhaust gas stream. The unit should have extremely low vibration as per specification.(Mandatory submission--> 100% technical complaince sheet should be submitted with the technical bid from original manufacturer.)Make- multitech/hitachi/Anistaiwata or Equivalent 32 Vacuum Tank of 5000 liters water capacity.Make- multitech/hitachi or Equivalent 33 Bacterial Filter:Vacuum Filter (Bacteria Filter) of 100 cfm to 105 cfm – 3” Filter housing with drain flask.: It fully complies and meets with requirements of UK HTM medical standards. It should have BS 3928 sodium flame test certificate based on requirements of HTM standards.The bacteria filter should be designed for critical application involving removal of dry and wet dust, particulars, oil aerosol and water droplest, high efficiency glass fiber, fieece media from suction side of vacuum pump system. It should have efficiency of at least 99.995% when tested by sodium flame test and that should be according to BS 3928:1969. The Vacuum filtration efficiency should be in excess of 99.9999% as per HTM0201 & AS 2896 standards. The high efficiency medical grade filter element should have custom engineered filter media and deep pleat element technology provides minimal pressure loss and filtration efficiencies. It should have advanced filtration technology for Low pressure loss borosilicate glass microfiber-media and open cell reticulated foam pre-filtration layer captures particulates, bacteria and liquid aerosols reducing energy consumption and overall system costs. It should have corrosion protection Internal and external electrophoretic painting followed by a tough exterior polyester powder coating.It should have easily removable sterilisable drain flask and differential pressure monitor gauge. It should have push fit element design for quick and easy maintenance with unique push fit element design. It should have element end cap color black. It should have maximum temperature 60 degree centigrade (140 degree F). It should have element of E31140MV grade. It should have pipe size connection 1” = 105scfm and 180nm3/hr FAA. It should have pressure loss clean & dry = < 3kPa (30m/bar/0.44psig). It should have maximum working pressure 0.5barg(7psig. It should have manual drain valves and 250ml sterilisable glass drain flasks.(Maximum tolearance allowed will be only 10%).Smooth mobility.Sturdy trolley mounted on 5 castor base wheels.Operational when connected to centralized vacuum.Fast connection to the vacuum source.Various Vacuum Connector options.Controllable & Stable vacuum for procedure.Step-less vacuum regulation within the range.Gauge needle with anticlockwise movement .Vacuum trap with bacterial filter in series to protect.system networkDisposable hydrophobic filter element.Quick hassle-free replacement of bacterial filter.Switch toselect collection jar & quicksuction shut-off.Easy access to selector switch.90 degree angular interface connectors to push-fit catheters.Autoclavable Polycarbonate collection jars.Overflow prevention trap on each collection jar.Make- Tridentor Equivalent 34 Ward Vacuum Unit with Regulator, Collection Jar of 1000 ml with Bracket.Make- Altos/Aktiv or Equivalent 35 Theatre Vacuum Unit mounted on Trolley consisting of Vacuum Regulator with Gauge and 2 nos. of 4000 ml Polycarbonate.Make- Altos/Aktiv or Equivalent 36 Bacteria Filter (Plastic) for 100 ml Safety Trap before Vacuum RegulatorMake- Altos/Aktiv or Equivalent 37 COMPRESSED AIR SYSTEM 38 SITC of COMPRESSED AIR SYSTEM AS PER SPECIFICATION 39 Oil Free Scroll Air Compressor: The arrangement should consist of 2 nos.oil free scroll air compressor. It should be rated for 50 Hz, 3 Phase, 415 VAC power supply. Motor rating of each compressor should be 22 Kw & 30 Hp. Each scroll compressor should have a flow capacity of minimum 73 cfm (2070 LPM). The scroll air compressors shall be air cooled. Compressors shall be oil free scroll compressors suitable for both continuous and frequent start/stop operation having outlet pressure control range of 800 to 1000 kPa (8 to 10 bar). Each compressor shall have at least two individual scroll elements. The air quality shall be 100% oil free, certified ISO8573-1. The compressor shall have a sound insulating enclosure. Each scroll air Compressor should have an element consists of a fixed scroll shaped housing and a scroll shaped rotor. Air enters the compressor element through inlet opening. Once the air is drawn in, the orbiting scroll seals the inlet opening and forces the air into a continuously decreasing space. As scroll keeps orbiting, this process of compression is constantly repeated, resulting in discharging of oil free compressed air through outlet opening. Air is drawn through air filter and should be compressed by the compressor element of each compressor module. The compressed air is discharged via the check valve and a common air cooler. The cooling air is blown over the compressor element via a duct. A separate electric fan provides cooling air for the common air cooler. Each set of compressor modules has its own common aftercooler with an electric fan. The separator on compressors without integrated dryer has an automatic condensate outlet and a manual drain valve. The air compressors with integrated dryer, the dryer is equipped with a trap with an automatic condensate outlet and a manual drain valve. Each compressor element is protected by a sensor in the outlet pipe. The sensor is connected to the electronic regulator. Make- multitech/hitachi/Anistaiwata or Equivalent 40 Air Receiver of 5000 Liter Water Capacity (designed to withstand pressure of 10 Bar) with Auto Drain ValveMake-multitech/ hitachi or Equivalent 41 Medical Breathing Air Dryer- 375 SCFM - Medical air dryer heatless with purification modules are intended to provide a continuous supply of medical quality air conforming to the European Pharmacopoeia medicinal air monograph (ref. 1238), for respiratory use in healthcare facilities. The system shall be duplex such that the supply is maintained in single fault condition. Medical compressors shall be provided such that the specified volumetric flow is achieved without standby or backup systems running. Purification Module : The duplexed filter and dryer module shall incorporate high efficiency oil coalescing filters, heatless regenerative desiccant dryers, activated carbon filters and bacterial filters. The performance of the filters shall be according to below specifications: Oil coalescing high efficiency filter: mass efficiency of 99,92%, tested according to ISO 8573-2 & ISO 12500-1; Activated carbon filter: max remaining total oil content of 0,003 mg/m³, tested according to ISO 8573-5 & ISO12500-2;Bacterial filter: particle count efficiency of 99,98% at MPPS=0.06μm, tested according to ISO 12500-3. Dryer Purge Control : The dryer control system shall incorporate a Purge Saver Energy Management system that freezes the regeneration of the desiccant once adequate dew point is reached in the inactive tower. Only when the dewpoint level in the active tower deteriorates to an unacceptable level will the intelligent controller switch towers.Coarse coalescing filter of 375 SCFM (one working and one as stand by) flow capacity: It should have flow-optimized design for advanced filter head design for optimized flow performance. It should have flexible installation Modular design and accessible fixings enable simple close coupling assembly. It should comply with air quality standard ISO 8573-1: 2010. It should have profiled bowl design and push fit elements ensure quick and for reliable maintenance. It should have corrosion protection Internal and external electrophoretic paint finish followed by a tough exterior polyester powder coating. It should have color coded element end caps of red color for easy and accurate grade identification. It should have element of E30612 grade.It should have particle retention of up to 99.999%, and significantly reduced pressure loss. It should have particle removal 1 micron. It should have maximum particle size class 2 micron as per ISO 8573-1: 2010 . It should have maximum oil content 3 micron ISO 8573-1: 2010.It should have maximum oil carryover at 68 degree F (20degree centigrade) = 0.3ppm (0.3mg/m3). It should have pressure loss clean & dry = 0.8psi (55m/bar). It should have pressure loss saturated = 1.8psi (125m/bar). 42 Fine coalescing filter of 375 SCFM (one working and one as stand by) flow capacity : It should have flow-optimized design for advanced filter head design for optimized flow performance. It should have flexible installation Modular design and accessible fixings enable simple close coupling assembly. It should comply with air quality standard ISO 8573-1: 2010. It should have profiled bowl design and push fit elements ensure quick and for reliable maintenance. It should have corrosion protection Internal and external electrophoretic paint finish followed by a tough exterior polyester powder coating. It should have color coded element end caps of blue color for easy and accurate grade identification. It should have element of E30612 grade.It should have particle retention of up to 99.999%, and significantly reduced pressure loss. It should have particle removal 0.01 micron. It should have maximum particle size class 1 micron as per ISO 8573-1: 2010 . It should have maximum oil content 1 micron ISO 8573-1: 2010.It should have maximum oil carryover at 68degree F (20degree centigrade) = 0.01ppm (0.01mg/m3). It should have pressure loss clean & dry = 1.2psi (85m/bar). It should have pressure loss saturated = 1.8psi (125m/bar). Activated Carbon Filter of 375 SCFM (one working and one as stand by) flow capacity: It should have flow-optimized design for advanced filter head design for optimized flow performance. It should have flexible installation Modular design and accessible fixings enable simple close coupling assembly. It should comply with air quality standard ISO 8573-1: 2010. It should have profiled bowl design and push fit elements ensure quick and for reliable maintenance. It should have corrosion protection Internal and external electrophoretic paint finish followed by a tough exterior polyester powder coating. It should have color coded element end caps of black color for easy and accurate grade identification. It should have element of E30612 grade.It should have particle retention of up to 99.999%, and significantly reduced pressure loss. It should have particle removal 0.01 micron. It should have maximum particle size class 1 micron as per ISO 8573-1: 2010 . It should have maximum oil content 1 micron ISO 8573-1: 2010.It should have maximum oil carryover at 68degree F (20degree centigrade) = 0.003ppm (0.003mg/m3). It should have pressure loss clean & dry = 1.7psi (115m/bar). 43 Fine Dust Filter of 375 SCFM (one working and one as stand by) flow capacity : It should have flow-optimized design for advanced filter head design for optimized flow performance. It should have flexible installation Modular design and accessible fixings enable simple close coupling assembly. It should comply with air quality standard ISO 8573-1: 2010. It should have profiled bowl design and push fit elements ensure quick and for reliable maintenance. It should have corrosion protection Internal and external electrophoretic paint finish followed by a tough exterior polyester powder coating. It should have color coded element blue color end caps for easy and accurate grade identification. It should have element of E30612 grade.It should have particle retention of up to 99.999%, and significantly reduced pressure loss. It should have particle removal 0.01 micron. It should have pressure loss clean & dry = 1.5psi (100m/bar). Make- Trident or Equivalent 44 Pressure Reducing Station for 4 Bar: The compressed air system shall be supplied with duplex pressure regulator arrangement to regulate the line pressure from 10 bar to 4 bar for medical air. Adequate number of isolation valves should be provided to isolate each regulator separately during maintenance without shutting down the entire compressed air system. Presssure Regulators should be 28 bar rated. Brass pressure relief valve, 1/4 thread BSP should be provided after the regulator. Pressure Gauge of range 0 to 11 bar to be provided to monitor line pressure. Relief Valve Settings : Nominal 4 bar stations - 5.5 bar relieving.The Pressure Reducing Station should be capable of delivering minimum 10000 LPM flow.It shall be duly CE marked to the Medical Device Regulations and under this regulations, med gas products are classified as Medical Devices. 45 Pressure Reducing Station for 7 Bar: The compressed air system shall be supplied with duplex pressure regulator arrangement to regulate the line pressure from 10 bar to 7 bar for surgical air. Adequate number of isolation valves should be provided to isolate each regulator separately during maintenance without shutting down the entire compressed air system. Presssure Regulators should be 28 bar rated. Brass pressure relief valve, 1/4 thread BSP should be provided after the regulator. Pressure Gauge of range 0 to 11 bar to be provided to monitor line pressure. Relief Valve Settings : Nominal 7 bar stations - 9 bar relieving.The Pressure Reducing Station should be capable of delivering minimum 4000 LPM flow.It shall be duly CE marked to the Medical Device Regulations and under this regulations, med gas products are classified as Medical Devices. 46 SITC of Medical Gas Outlets- 47 Probes are crucial for gas specific and stable connection. These are used to connect medical gases and vacuum devices to outlets / terminal units of MGPS distribution network.Make- Altos/Altos/Aktiv or Equivalent 48 FeaturesSmooth quiet action.Safe keying configurations.Gas specific ISO 32 colour coding.Firm locking of connector / probe.Strong, positive and secure connection.Corrosion-free and material compatibility.Reliable and safe dispense of gases & vacuum.Pipe stub end flared to align drop pipe and to avoid butt joint. 49 Oxygen 50 Air-4 51 Air-7 52 N2O 53 AGSS 54 Vacuum 55 CO2 56 Certifications:ISO 13485:2016 – Medical devices,ISO 9001:2015 57 MISCELLANEOUS ITEMS 58 SITC of Common Electrical Control Panel for Compressed Air System, Vacuum System & AGSS as per requirementcomplete with plant room wiring. 59 SITC of Degreased Medical Grade Copper Pipe as per EN 13348 :2018. BSI Kite Mark certified. CE Certified. Third Party Inspection by TUV or Lloyds Registrara AsiaMake- Altos/Altos/Aktiv or Equivalent 60 Installation of piping should be carried out as per international standards with utmost cleanliness. Only pipes, fittings and valves which have been degreased as per International standards should be used . Pipe fixing clamps for upto 28mm diameter. Pipes should be non ferrous suitable for the diameter of the pipe. For the pipes of the sized above 28mm rigid metallic hanging or cemented supports to be used. 61 The main lines to the building to be taken overhead through metallic poles or through underground ductswith inspection removable slabs,All pipe joints should be made using inert gas fluxless brazing method.Alljoints should be of copper to copper and should be brazed by silver brazing filler material without flux while being brazed joints shall be continuously purged with oil free dry nitrogen to prevent the formation ofcopper oxide on the inside surface of the joint.All pipes should be installed without springing or forcing.All pipes shouldprotected against mechanical injury in a manner satisfactory to authorities havingjurisdiction. 62 Test: After erection, all the new pipes cleaned or purged with the help of dry nitrogen gas.Complete system should be tested with dry nitrogen at 2 times of working pressure for 24 hours. 63 Painting: All existing and proposed exposed pipes/should be painted with two coats of Synthetic enamel paint & color codification as per international standards.All concealed pipes to have gas identification bands / labels at appropriate distance.Similarly all pipes which need embedding in the wall should be tested/painted/labeled and properly insulated. 64 Solid drawn, seamless, deoxidized, non arsenical, half hard, tempered and degreased materials conforming to BS: EN 13348. 65 All copper pipes will beUL certified for medical use before dispatch and the pipe will be delivered plugged or capped at both ends. 66 108 mm OD X 1.5 mm thick 67 76 mm OD x 1.5 mm thick 68 54 mm OD x 1.2 mm thick 69 42 mm OD x 1.2 mm thick 70 35mm OD x 1.2mm thick 71 28 mm OD x 1 mm thick 72 22 mm OD x 1 mm thick 73 15 mm OD x 1 mm thick 74 12 mm OD x 0.7 mm thick 75 SITC of Medical Gas Digital Area Alarm System 76 Microprocessor based digital LCD alarmHighly visible 7 (178 mm) LCD screenPressure sensing through piezoresistive sensing technologyAlarms can be monitored audio-visualTouch screen operationComprehensive monitoring of all the medical gas alarm panelsData display at a central monitoring station Features-Alarm status will be visible through ethernet port on master alarmPressure Equipment Directive 2014/68/EUDigital Flow Care Alarm Management of Medical Gas Pipeline SystemReal time updating of statusOperational parameters i.e. high and low level canbe set “in-situ” to suit requirement in an area 2Programmable pressure unit display (bar, kg/cm & mmHg)Audio mute optionDesigned to serve 2, 3, 4, 5 & 6 gases including VacuumNIST connection for Gas inputPowered by 220V AC to 24V DC external adapterMake-Altos/Aktivor Equivalent 77 Conforms to: IS / ISO 7396 - 1 : 2016 + A1 : 2017HTM 02-01 Part A, IS / ISO IEC 60601 - 1 : 2015 + A1 : 2020Certifications:ISO 13485:2016 – Medical devices – Quality Management SystemsISO 9001:2015 - Quality Management Systems 78 6 - Gas (O2, N2O, Med Air-4 Bar, S Air-7 Bar, Vacuum & CO2) 79 5 - Gas (O2, N2O, Med Air-4 Bar, S Air-7 Bar & Vacuum) 80 4 - Gas (O2, N2O, Med Air-4 Bar & Vacuum) 81 3 - Gas (O2, Med Air-4 Bar & Vacuum) 82 2 - Gas (O2 & Vacuum) 83 SITC Of Area Valve Service Unit with Valve & Gauge 84 The importance of full bore ball valves is to reduce pressure drop to almost negligible in the pipeline distribution system so that the designed pressure is available at the outlet point. Ball Valves are used to start or stop a flow. In Medical Gas Pipeline System (MGPS), the valves are normally kept open i.e. allow the gas to flow unless it is required to shut-off the gas supply for scheduled maintenance or emergency situation 85 Features-Operational parameters can be set in-situDigital pressure unit display options -psi / bar or kg/cmDigital & illuminated LED display of “Normal”, “High” & “Low”Microprocessor based moduleHighly accurate “Heavy Duty” pressure transducerPowder coated aesthetically designed enclosureEnclosure separable from the base for ease of installationReusable lock assemblyAudio mute optionPED: 2014/68/EU certified full port Ball Valve (PN 30)Long extension copper pipes to connect MGPS networkFront door opens up vertically for comfortable accessDesigned to serve 2, 3, 4 & 5 gas moduleSuitable for all medical Gases & VacuumMake- Altos/Aktiv or Equivalent 86 6 Gas Service (O2, N2O, Med Air-4 Bar,Air-7 Bar, Vacuum & CO2) 87 5 Gas Service(O2, N2O, Med Air-4 Bar, Air-7 Bar & Vacuum) 88 4 Gas Service(O2, N2O, Med Air-4 Bar & Vacuum) 89 3 Gas Service (O2, Med Air-4 Bar & Vacuum) 90 2 Gas Service(O2 & Vacuum) 91 SITC of Degreased Medical Lockable Ball Valve with Pipe line assembly 92 Pre piped single port) for size upto 2 (for 54mm copper pipe): Pre Piped Degreased Ball Valve with pipe extension. It should be full-port design. It shouldbe blow-out proof stem. It should be lockable valve. The Valve shall be 3 piece ball-type design with a bronze body and chrome plated brass ball for sizes 1/2” to 4”. Seats shall be Teflon (TFE) and seals Viton for 1/2” - 4” valves. A blow-out proof stem shall be used and the valve shall have a maximum pressure rating of 600 psi [4,137 kPa].Valves shall be operated by a lever-type handle requiring only a quarter turn from a fully open position to a fully closed position. Valves shall be designed in such a manner that it can be “swung-out” during installation so as to prevent damage due to heat transfer during the brazing operation. Each valve assembly shall be washed and degreased for medical gas service. The valve shall be supplied in a sealed plastic bag to prevent contamination prior to installation.Make- Altos/Aktiv or Equivalent 93 12mm 94 15 mm 95 22 mm 96 28 mm 97 35mm 98 42 mm 99 54 mm 100 108mm 101 SITC of Bed Head Panel aluminum powder coated with mininum 3 channel and 3 duct with separate partition rows and built in aluminum railMake- Altos/Aktiv or Equivalent 102 Bedhead panel for Low Equity Ward Areas, 1500mm length, with provision of Gas outlets & provided with electrical sockets & accessories complete 103 Horizontal Bed Head Panel – For 2 Gas Service (Oxygen & Vacuum) 104 Horizontal Bed Head Panel – For 3 Gas Service (Oxygen, Med Air-4 Bar & Vacuum) 105 Horizontal Bed Head Panel – For 3 Gas Service (Oxygen, N2O & Vacuum) 106 Horizontal Bed Head Panel – For 4 Gas Service (Oxygen, N2O, Med Air-4 Bar & Vacuum) 107 Special FeaturesInnovative design – Efficient, simple & accessibleVersatility – Configurable & economic adaptation of various servicesAesthetics – High quality surface finish, epoxy coated to RAL 7035(Textured)Smooth profile – Minimize adherence of dust particlesExtruded aluminium frame – Rigidity & ease of interior accessability to serviceSeparate compartments - for LV, ELV and Piped GasNon-disruptive maintenance of BS Outlet - Shut down of line gas is avoidedOption of concealed gas connections and choice of outlet 108 Application AreasInnovative design – Efficient, simple & accessiblityVersatility – Configurable & economic adaptation of various servicesAesthetics – High quality surface finish, epoxy coated to RAL 7035(Textured)Smooth profile – Minimize adherence of dust particlesExtruded aluminium frame – Rigidity & ease of interior accessability to serviceSeparate compartments - for LV, ELV and Piped GasNon-disruptive maintenance of BS Outlet - Shut down of line gas is avoidedOption of concealed gas connections and choice of outletAdult in-patient wards/ General WardsResuscitation RoomsPost-anaesthesia areaEmergency Admission WardsDialysis Stations 109 Configuration : 5 Outlets & 6 Multi Standard 220V AC sockets, 1 each RJ11 Telephone socket & RJ45 Data Socket and provision of protective earth (Earthing) 110 Modular Operation Theatre (Part-B) 111 WALL AND CEILING MODULAR PUF PANEL 112 The panels shall be made of durable and uniform material that shall be easy to clean and extremely hygienic. Operation theatre shall not have any sharp edges, corners and shall not support bacteriological or fungicidal growth and shall be resistant to most chemicals, commonly used in Hospital Departments. Joints in the panels in the operation theatre shall be sealed. The function of sealing shall assure an airtight environment in the room and eliminate services to prevent dust accumulation.PUF Panel with an overall thickness of 50 mm for wall and 30 mm for ceiling, made of 0.8mm (make-Tata/jindal)GI Front sheet and 0.6mm PPGI back wall with infill of PUF at 40 kg/m3 (40D)which is necessary for mechanical strength. Panels shall be mounted on a structure made of galvanized steel and shall enable the distribution of medical gases, electricity, sewerage inside the wall.PUF Panel as above has better thermal efficiency and thus saving on energy cost. Proposed system shall be installed at site without any welding.The partitions shall not have corners; adjacent surfaces shall be molded flush.Upper wall element shall have sufficient height to reach the lower edge of the prefabricated ceiling. All the sharp edges and corners should be chamfered to avoid bacterial contamination.The individual ceiling panels shall use the tongue and groove technology for joining two panels, no welding shall be allowed,provides a seamless sub-structure, which is then sanded smooth finished with Metal Putty and then painted using imported anti-fungal paint to give a smooth, non-porous seamless finish and without corners by providing coving on floor as per standard.It is resistant to chemicals used in Operation Room for moping and fumigation repeatedly.Make-Jindal/Tata or Equivalent 113 WALL AND CEILING MODULAR PUF PANEL-SS304 114 The prefabricated Operating Room should be of SS Sandwich as per its latest standards. SS Sandwich : It should have at least min. 0.8 mm 304 Grade Stainless Steel on front side and 0.5mm PPGI back side . The sandwich panel shall have a core consisting of rigid polyurethane foam, injected under high pressure, with a minimum density of 40 kg/m3. Cladding structure insulated stainless steel wall panels with total panel thickness 50 mm for wall and 30mm for ceiling.The individual wall panels shall use tha tongue and groove technology for joining two panels, no welding should be allowed. The gaps between panels shall be suitably filled with metal filler and sanded flush. Stainless steel plate finished to fine grain surface, treated properly to take antifungal paint panelingshould be easy to maintain, durable, antistatic / conductive and fire retardant. Clearance between inner panel and outer wall should be sufficient to allow the maintenance personnelfor service. This closed space should be flushed continuously to eliminate dust and bacterial accumulation.It should have minimum number of junctions. The junction should be seamless and should be sealed with suitable sealants. Third party test certificate for SS from material testing lab. (Govt. authorized)required.Make-Jindal/Tata or Equivalent 115 ANTI-FUNGAL PAINTING 116 Anti microbial Paint for Different Areas antibacterial Paint on wall and ceiling panels Inside OT work.Anti-Microbial Protection: These product hygiene coatings start the biocidal action as soon as the microorganism land on the surface, and prevents the growth of mould, bacteria and yeasts for at least 5 years.Minimum three coats of Anti Fungal/Bacterial Paint, glaze or equivalent to a minimum dry thickness of 300 microns to give smooth , non-porous finish without any corners.It will also be resistant to the chemicals used in Operation Room for Moping & Fumigation repeatedly. This Hygiene coating are independently tested by leading universities to demonstrate resistance.Make-SKK/ Jotun or Equivalent 117 PLENUM LAMINAR AIR-FLOW 118 Supply and installation of Plenum LAMINAR FLOW- Plenum Box Ceiling mounted systemwith unidirectional airflow, SPECIFICATIONS-PLENUM UNIT - The complete unit factory designed and manufactured with proper air-sealing. It seamlessly integrates with OT ceiling mounted equipment.Plenum size- 2400 x 2400mm with aluminium material.Diffusers are made of SS304 punched/perforated sheet for unidirectional diffusion air. The complete unit factory designed and manufactured with proper air-sealing.It seamlessly integrates with OT ceiling mounted equipment.The material used is non-corossive as per standard guidelines such as Aluminium.Make-Jindal/Tata or Equivalent 119 Hepa Filters- 120 The filter hosing on either side houses provided with HEPA minipleate H13/H14 filters.The system has a reliable filter efficiency, filters are designed to remove particles and germs with the use of H13/H14 filters retaining 99.97 % of the particles and germs.Frame : Aluminium Mini Pleat Size- 610x610x125mmMOC of the Media : Micro Fibre Glass micro drawn grid Separators : continuous Gasket: Food GradeMPPS average efficiency: > 99.95% 3 Micron D Efficiency: 99.97% down to 0.3µ.Maximum Operating Temp : 60 degree CelsiusMake- Thermadyne or Equivalent 121 ANTI-STATIC VINYL FLOORING: 122 SupplyandinstallationofImportedVinylFloor:SeamlessantistaticconductiveESDvinylflooringsystem,2mmthick, with perfectly curved flush covings and copper strips for earthing, all joints welded properly including wall scatting.SPECIFICATIONS:- Flooringinoperationtheaterroomwii beseamless withperfectly curvedflash-covings,resistance tomechanicalstressanddynamicloadsandhavingESD/EMI(Conductive)protectioncharacteristics,2mmthick, washablevinyl.Flooring is a static-conductive,flexible homogeneousvinyl floor covering withan electricalresistance of 5x10^4 123 SELF LEVELLING MATERIAL. 124 The SLC should be of Portland cement-based, It should be self-leveling underlayment formulated with a special blend of polymersusedtolevelandsmoothinteriorconcrete,terrazzo,ceramicandquarrytile,epoxycoatingsystems,metal andnon-watersolubleadhesiveresidueonconcretepriortotheinstallationoffinishedflooring–on,aboveorbelow grade.TheSLCshouldprovideadurable,flat,smoothfloor surfacewithminimumlabor andinstallationtime.Itshould be pourable or pump-able when mixed with water and should seek its own level to produce a smooth, flat, hard surface. 125 OPERATION THEATRE CONTROL PANEL: 126 Supply and installation of Membrane type 6 services OT control panel , with distribution box mounted flush in the theatre wall, comprising of the following:The surgeon control panel should meet Electrical safety codes for high & low voltage system, wired to the current IEE regulations.The room Surgeon’s control panel should be modifiable with changing technology& equipment in operating environments. Control Panel will be user friendly & ease of operating & maintaining purpose.he panel should be “Membrane” type; configured to incorporate all the services that operation room staff required. The fascia should be made with superior quality UV resistance membrane with sterilization feature.The Panel should contain 6 or 9 service tiles as below:1. Time Day Clock. 2. Time Elapse Day Clock. 3. General Lighting System.4. Medical Gas Alarm Panel. 5. Hand Free Telephone set with memory.6. Temperature & humidity indicator with controller.7. HEPA Filter Status module. 8. Room Pressure Indicator. 9. Music control. Time day clock should be digital type & clocks having high brightness characters. Time Elapsed Day Clock should be digital type & clocks having high brightness characters.Temperature indicator should indicate the room temperature which should be connected to the local pressure switches of Air-Conditioning System. Indicators should be digitaltype & clocks having high brightness characters, not less than 30 mm in height. Central Lighting system should incorporate all the necessary controls of the lighting. system inside the theatre.The medical gas alarm should indicate High, Normal & Low gas Pressure for each gas service present in the operating system & should have an audible buzzer with mute facility. Pressure sensors should be connected to MGPS for monitoring the pressures.A hand free set Telephone System should be incorporated in the panel with memory type card.The control panel should be designed for front- access only. All internal wires should beMake- Altos/DGline or Equivalent 127 Distribution Board outside OT 128 Electrical Distribution Board will have all high voltage equipment should be installed in a separate enclosure. The remote cabinet should house the operating transformers, light control relays, electrical distribution equipment and circuit protection equipment for all circuits withinthe operating theatre. All internal wiring should terminate in connectors with screw mounted, on a DIN rail. Individual miniature circuit breakers will protect all internal circuits. All high voltage equipment should be installed in a separate enclosure.All internal wiring should terminate in connectors with screw & clamp springConnections of the clip- on type mounted, on a CE/ / ICMED9001/ ICMED13485 approved rail & labeled with indelible proprietary labels.Individual fuses or miniature circuit breakers should protect all internal circuits. 129 LED PERIPHERAL/GENERAL LIGHTS: 130 Recess mounted sealed IP54 Protocol, non-hygroscopic peripheral lights ( 1 x 2 ) having compact high glow low wattage LED lighting system. These lights are having electrical safety code for high & low voltages.The luminaries for recess mounting in operation theatres should flush with the ceiling based on LED, with optical anti- glare system for individually adjustable light distribution.Luminaries cover made of highly-resistant, disinfectant-proof acrylic diffuser with white coated steel frame.Closing devices are integrated automatically in the electrical safety control without lines having to be connected to the luminaries housing. Luminaries’ body made of sheet steel, white, powder-coated, supplied ready for connection optionally for individual or group with power saving technology. Luminaries with protection IP 65, and protection class I,230 V,50 Hz.Recess frames for the gas-tight installation of clean-room luminaries in IP 65 in suspended ceilings.Frame made of extruded aluminium profile, white, powder-coated, able to be put together to form a rigid, continuous frame by means of plug and screw connections.Control equipment for the general lighting and the light dimming should be provided in the theatre Control Panel.Make-Altos/DGline or Equivalent 131 LED X-RAY VIEW PANEL: 132 TwoPlateX-RayViewScreenwithflickerfreeilluminationhavingimportedLEDsystemforuniformilluminationand operated by X-ray film .Thesystemhavingelectricalsafetycodesforhigh&Lowvoltagesystem.Itshouldbedesignedtoprovideflickerfree luminance for the film viewing purpose.It should be installed flushed with the theatre wall for hygiene and ease of cleaning.Make-Altos/DGline or Equivalent 133 MAGNETIC LISTING WRITING BOARD: 134 MagneticWritingBoard of size940x 640x50mmcomprisesof aflushmounted,1.50mmthick,whitelaminate board, bonded toa 10 mm high density fibreboard sheet for additional rigidity.The writing unit should comprise of flush mounted white laminate board, be opened to create a wall mounted writing surface within the operating room. The white board should be constructed from white laminate board.Make- Altos/Dgline or Equivalent 135 AUTOMATIC HERMETICALLY SEALING SLIDING DOOR -1500mmX2100mm 136 Automaticoperated Hermettically Slidingdoor with High Pressure Laminate on both side, Door size (1500mm wide2100mmheight)completewithdoubletoughnedglassvisionwindowof300mmx300mm withinanaluminum extrusionhighqualityframecompletewithrequiredaccessories.Thedoorframesconsistofreinforcedplasterboard panelsfacedwiththesamelaminateasthedoorandwillbeedgedwithanaluminiumextrusionandwithconcealed fixings that are adjustable during installation to ensure sealing.• Environment temperature should be -20°C to +55°C.The doorframe should be made of high quality anodize aluminum and the door panel should be made of compact laminate that can withstand high abrasion. To ensure efficient sealing of the doors frames should be provided. They will consist of reinforced plasterboard panels faced with the same laminate as the doorsVision panels, 300mm X 300 mm should be provided in the doors.The Door should be mounted and should complete with all necessary accessories i.e.Door closer, D type SS Door HandleMake-Metaflex/Doormedor Equivalent 137 HERMETICALLY SEALING HING DOOR-900mmX2100mm 138 Manually operated Hermettically Semi- sealed Hing door with HighPressure Laminateon bothside, Door size (900mm wide x 2100mm height) complete with double toughned glass vision window of300mm x300mm andsmooth effortless doorcompletewithrequiredaccessories,fixedfirmlytothewall.Thedoorframesconsistofreinforcedplasterboard panelsfacedwiththesamelaminateasthedoorandwillbeedgedwithanaluminiumextrusionandwithconcealed fixings.• Environment temperature should be -20°C to +55°C.The doorframe should be made of high quality anodize aluminum and the door panel should be made of compact laminate that can withstand high abrasion. To ensure efficient sealing of the doors frames should be provided. They will consist of reinforced plasterboard panels faced with the same laminate as the doorsVision panels, 300mm X 300 mm should be provided in the doors.The Door should be hinge mounted and should complete with all necessary accessories i.e.Door closer, D type SS Door Handle. The door track is constructed from an aluminium extrusion, fixed firmly to the wall. Nylon runner guides are fixed to the floor in such a way that they do not obstruct trolley movement through the door.Make-Metaflex/Doormed or Equivalent 139 CORNER GRILLS 140 Aluminium corner grills are used to air exhaust at all four corners.size of grill will be 600mmX400mm.Duly powder coated extruded aluminium linear horizontalfixed bar with normal 15 deg. blade having pitch of 13 mm.Exhaust Gril for return air-The exhaust air cabinets should be openable and cleanable. These cabinets should have suction from bottom.Distribution of exhaust air volume should be divided between fluff strainers to maintain the required pressure within the theatre without causing turbulence.The Exhaust air cabinet should be manufactured and supplied by the supplier of wall and ceiling system supplies. Also it should match perfectly with the ceiling system aesthetically.Make-conair/Bala ji engineering or Equivalent 141 ALUMINIUM DUCTING: 142 Aluminium Ducting ( 22 gauge ) with curves & bends where indicated for easy flow of air tight by applying silicon sealant after fabrication.Hangers will be provided to ducts & will be suspended be means of G.I. coated rod & these will not be more than 2.5 mtrs apart.Thermal insulation with 9/13mm XPE with aluminium foil for supply & return air ducts.Joints will be lapped with Nitrile tape for better insulation. (Laminar to AHU & Return air in all four corners) AHU to be placed near OT, not more than 6 meter.SITC OF Hand fabricated rectangular Aluminum Ducting in accordance with the approved ducting lay out drawing, complete with all accessories , dampers, guide, vanes, support, etc.Make-Hindalco/Virgo or Equivalent 143 AIR HANDLING UNIT 144 AHU System & Condensing Unit with consistingDOUBLE SKIN CASING: Outer Skin 0.6 mm Pre- Coated GI Inner Skin 0.6 mm Plain GI Frame Work Hollow Extruded AL Profile Thickness of Insulated Panels 25 mm thick, CFC Free PUF injected (Density: 40 kg / Cu. m.) Material ofDrain Pan 20 G SS-304 Tray duly insulated with 13 mm closed cell Nitrile insulation. Unit Base G.S.S Base Channel DX COIL: Make Of Coil ZECO Coil Casing / Blank offs GI Material Of Tube Copper (IGT) Tube Dia (mm / inch) 9.52 mm / 3/8” O.D. Thickness of tube (SWG / mm) 25 SWG / 0.5 mm Header Material Copper Thickness & Material of fins 0.15 mm Plain Aluminum No. of Fins per inch (FPI) 11 / 12 FILTERS: Media of Filters Synthetic (non woven type) Efficiency of Pre-filters (EU-4) 90 % down to 10 micron. Efficiency of Fine-filters (EU-5) 99 % down to 05 micron FAN & MOTOR: Fan make Nicotra Motor make CG Motor type TEFC Squirrel Cage IP 55 Protected VFD Compatible induction motor VFD: VFD make DELTA DOUBLE SKIN FLOOR MOUNTED HORIZONTAL AIR HANDLING UNIT SHALL HAVE:(WITH 25MM THICK PANEL) ◻ Mixing box with manually operated FA & RA damper in GI constructionDOUBLE SKIN CASING: Outer Skin 0.6 mm Pre- Coated GI Inner Skin 0.6 mm Plain GIFrame Work Hollow Extruded AL ProfileThickness of Insulated Panels 25 mm thick, CFC Free PUF injected (Density: 40 kg / Cu. m.) Material of Drain Pan 20 G SS-304 Tray duly insulated with 13 mm closed cell Nitrile insulation. Unit Base G.S.S Base ChannelDX COIL: Dx type coils having suitable number of distributors for connecting expansion valve with condensing unitsMake-Zeco//VTS or Equivalent 145 Make Of Coil Casing / Blank offs GI Material Of Tube Copper (IGT)Tube Dia (mm / inch) 9.52 mm / 3/8” O.D. Thickness of tube (SWG / mm) 25 SWG / 0.5 mm Header Material CopperThickness & Material of fins 0.15 mm Plain Aluminum No. of Fins per inch (FPI) 11 / 12FILTERS: Media of Filters Synthetic (non woven type)Efficiency of Pre-filters (EU-4) 90 % down to 10 micron. Efficiency of Fine-filters (EU-5) 99 % down to 05 micron VFD: DOUBLE SKIN FLOOR MOUNTED HORIZONTAL AIR HANDLING UNIT SHALL HAVE: (WITH 25MM THICK PANEL)Mixing box with manually operated FA & RA damper in GI constructions.Filter section with 50 mm thick (EU-4) box type pre filter with 305 mm thick (EU-5) bag type fine filter mounted on common filter frameCoil section with 6 row deep DX cooling coil with suitable distributor. Heater Section with GI strip Heater.Fan section with SISWbackward curved plug fan & Motor (IE-2). Manually operated SA damper in GI construction.Tonnage TR 8.5 Air Qty (CFM) 3500SP (mm wg) 125 UnitFan Type Plug Fan-355Fan model RLC E6-3135-23-19 Fan RPM 3400Motor RPM 2880Shaft Absorbing Power 3.2 Motor Rating (kw) 3.7 Motor pole 2Coil area (Sq.Ft.) 7.0 DX Cooling Coil RD 6 Distributor 1Heater KW3Filter area (Sq.Ft.) 8.0 Length (mm) 2500Width (mm) 1400 Height (mm) 945 146 AIRCONDITIONING: (8.5 T AC ) 147 Nominal Cooling Capacity-8.5tr,102000Btu/hr,29894watt Nominal Air Quantity-6250CFMPower Supply (V-ph-Hz)-400 ± 10% -3-5 Fan-PropellerDischarge-HorizontalFan Motor-Permanent Split Capacitor Type Power (watt)-470Control Type-LED DisplayOverall dimensions (mm)-982 X 610 X 1100 mm- Compressor- Scroll CompressorRefrigerant-R-410A (5.6) Liquid Line-5/8Suction Line-1-1/8Make- Carrier or Equivalent 148 ELECTRICAL WIRING INSIDE THE OT 149 Electrical Wiring as per requirement of OT, Wiring With OT distribution electrical Panel. ( Power cable at OT with Main distribution Panel will be provided by customer) Operation theatre shall be installed in the remote cabinet.All electrical wiring should be terminated to the connectors mounted on DIN/CE approved rail and labeled with indelible labels.Individual fuse and miniature circuit breakers should protect all internal circuits.Complete schematic diagram drawing description should be enclosed with the equipment. Makes:Scheinder/PolyCab/ Schematic.Supply, Installation, Testing and Commisnoing of Electrical Distribution Board with required MCB : It should be installed in a separate enclosure.Transformers,Mains,Relays,Circuitprotectiveequipment,forallcircuitsofOperationtheatreshallbeinstalledinthe remote cabinet. 150 MEDICAL GAS PIPE-LINE SYSTEM INSIDE OT 151 Medical Gas Pipe Line inside the OT above ceiling as required, complete with valve box and other required fitings. Medical Gas copper pipeline inside the OT and the Provision to connect to Pendant Systems (inside OT only).It should be confirm and meets with BS:EN:13348:2008 copper pipes.All medical grade degreased copper pipes must be inspected and duly Third Party Certified by Lloyd’s Registered Asia. Medical Grade Copper pipes manufactured from Phosphorous de-oxidized non-arsenical copper to BS:EN: 1412:1996 grade CW024A (Cu-DHP) manufactured to metric outside diameters and having mechanical properties in accordance with BS:EN: 13348:2008 & 250 or 290 (Half hard).Degreasing of pipe shall be such that there is less than 20 mg/m2(0.002mg/cm2) of hydrocarbons on the degreased surface when tested by the method specified BS:EN:13348:2008.Make- Altos/Aktiv/Mandev tubes/Mehta tubes or Equivalent 152 PASS BOX SIZE-2FTX2FTX2FT 153 Pass Box to remove the waste materials from the Operation Room to the Dirty Linen Area. Each box is equipped with two doors and the door should be operated electronically.. It is designed in such a way that only one door can be opened at one time. UV light is so installed that it is kept on while both the doors are closed and turned off automatically when the doors are opened. Indicators on both side of the Operation Room for Door Open/Close status. It is made of SS-304 Grade.Make- Jindal/Tata or Equivalent 154 STORAGE UNIT 155 Storage Unit of size 850x1600x350 mm has made of 1.6mm galvanised steel sheet. The exterior glass doors has lockable with magnetic push-button for easy opening. Removable toughened glass shelves of thickness 5 mm will be provided with the storage units.Make- Jindal/Tata or Equivalent 156 Pressure Relief Dampers 157 Pressure relief dampers should be provided in each room to prevent contamination of air from clean and dirty areas. Suitably sized air pressure relief damper should be strategically placed, enabling differential room pressure to be maintained and ensure that when doors are opened between clean and dirty areasCounter- weight balancing system should be provided in the PRD to maintain positive pressure inside the operation room.Air pressure stabilizers should have unique capability of controlling differential pressure to close tolerance.The PRD should remain closed at pressure below the set pressure and should open fully at a pressure only fractionally above the threshold pressure.The body of PRD sleeve and Grill should be epoxy powder coated as per standard High grade SS304 Stainless steel plate should be used for body and for bladesMake- Jindal/Tata or Equivalent 158 OT Pendant –Single Arm Anesthesia(Modular) 159 Anesthesia Pendent Systems should have the facility to provide convenient positioning of medical equipment.The support arms should be extremely robust and revolve on high quality bearings, so that the pendant head glides smoothly and quickly to any desired position.The Support arm should have atleast 10 mm thickness throughout to prevent any unnecessary deflection in Arms at given load.Arm Caps should be Aluminum Die casted Powder coated that allows its opening and closing a number of times as compared to ABS/Plastic end caps.High quality bearings shall be used to provide smooth and free movement, minimizing the force required to overcome static friction forces during repositioning. Bearings shall be permanently lubricated and sealed, withno maintenance or replacementPendant arms other than the cantilever lift arm shall be manufactured from extruded aluminium sections and available in various lengths. External surfaces of all arms shall be polyester powder coated in a RAL 9002/9003 finish. Tandem pendants for critical care areas shall be designed so that the consoles can readily swap sides within the bed bay to maximize the flexibility of the workspace.Non-return valves shall be fitted downstream of the connection to the medical / surgical air pipeline to prevent back-flow in the event of low distribution system pressure.Each arm should be capable of 330 – 340 degrees of rotation and be fitted with stops which can be easily adjusted to suit the desired mode of operation.Infinitely variable rotational stops should be available from 0-330 degree which shall enable precise of limits travel to be set to ensure maximum freedom of movement, whilst protecting walls and ancillary equipment.The rotational stops shall be dampened such that when limit of travel is reached, sensitive suspended equipment is not subjected to shock or vibration as the kinetic energy is absorbed.The arms may be fitted with pneumatic brakes or electromechanically breaks to prevent inadvertent movement.It should be possible to replace all medical gas hoses without the need for onsite crimping of ferrules. All medical gas hoses shall be colour coded to as per standard.The Pendant Service Heads / Column should be capable of accepting a range of shelves, drawers and infusion poles or other accessories. The Pendant Heads / column should support the range of Physiological Monitor Mounting Solutions. Service head should designed to host, Base, Gas Module, Electric Module and shelves.Make- Altos/Aktiv or Equivalent 160 The Pendant Service Heads / column should be supplied with medical gas terminal units. The medicalgas outlets fully comply with ISO 7396-1 and DIN 13260-2 standards. Medical gas hoses fully comply with thestandard BS EN 739 and are provided with NIST connectors to this standard. 161 Each anaesthesia pendant should be Single arm having rotational movement with load carrying capacity of minimum 120 kg having following facilities:movable Arm with total coverage of minimum 1000 mm and 330 degree.The Pendant Service Head/column should be modular with minimum 1200 mm head. Gas outlets: O2 – 2 nos, N2O – 2 no, Air (4 Bar) – 2 no, Vac – 2 nos, AGSS – 1 no. Medical rail with brake buttons fitted. - 1 No.Shelf with Drawer – 1 no. Infusion set – 1 no.Electrical Sockets – 10 nos. 6/16 Amp. 6 pin sockets. Pendants should comply with applicable standard:The terminal units must be according to ISO 7396-1 and DIN 13260-2 standards.Medical gas hoses shall be compliant to ISO 5359:2009 colour coded throughout its lengt 162 OT Pendant -SURGICAL PENDANT : 163 Surgon Pendent Systems should have the facility to provide convenient positioning of medical equipment.The support arms should be extremely robust and revolve on high quality bearings, so that the pendant head glides smoothly and quickly to any desired position.The Support arm should have atleast 10 mm thickness throughout to prevent any unnecessary deflection in Arms at given load.Arm Caps should be Aluminum Die casted Powder coated that allows its opening and closing a number of times as compared to ABS/Plastic end caps.High quality bearings shall be used to provide smooth and free movement, minimizing the force required to overcome static friction forces during repositioning. Bearings shall be permanently lubricated and sealed, withno maintenance or replacementPendant arms other than the cantilever lift arm shall be manufactured from extruded aluminium sections and available in various lengths. External surfaces of all arms shall be polyester powder coated in a RAL 9002/9003 finish. Tandem pendants for critical care areas shall be designed so that the consoles can readily swap sides within the bed bay to maximize the flexibility of the workspace.Non-return valves shall be fitted downstream of the connection to the medical / surgical air pipeline to prevent back-flow in the event of low distribution system pressure.Each arm should be capable of 330 – 340 degrees of rotation and be fitted with stops which can be easily adjusted to suit the desired mode of operation.Infinitely variable rotational stops should be available from 0-330 degree which shall enable precise of limits travel to be set to ensure maximum freedom of movement, whilst protecting walls and ancillary equipment.The rotational stops shall be dampened such that when limit of travel is reached, sensitive suspended equipment is not subjected to shock or vibration as the kinetic energy is absorbed.The arms may be fitted with pneumatic brakes or electromechanically breaks to prevent inadvertent movement.It should be possible to replace all medical gas hoses without the need for onsite crimping of ferrules. All medical gas hoses shall be colour coded to as per standard.The Pendant Service Heads / Column should be capable of accepting a range of shelves, drawers and infusion poles or other accessories. The Pendant Heads / column should support the range of Physiological Monitor Mounting Solutions. Service head should designed to host, Base, Gas Module, Electric Module and shelves.The Pendant Service Heads / column should be supplied with medical gas terminal units. The medical gas outlets fully comply with ISO 7396-1 and DIN 13260-2 standards. Medical gas hoses fully comply with thestandard BS EN 739 and are provided with NIST connectors to this standard.Each anaesthesia pendant should be Single arm having rotational movement with load carrying capacity of minimum 120 kg having following facilities:movable Arm with total coverage of minimum 1000 mm and 330 degree.The Pendant Service Head/column should be modular with minimum 1200 mm head. Gas outlets: O2 – 2 nos, N2O – 1 no, Air (4 Bar) – 1 no, Vac – 2 nos.Medical rail with brake buttons fitted. - 1 No.Make- Altos/Aktiv or Equivalent 164 Shelf with Drawer – 1 no. Infusion set – 1 no.Electrical Sockets – 10 nos. 6/16 Amp. 6 pin sockets. Pendants should comply with applicable standard:The terminal units must be according to ISO 7396-1 and DIN 13260-2 standards.Medical gas hoses shall be compliant to ISO 5359:2009 colour coded throughout its length. 165 UV LIGHT INSDIE OT FOR CLEAN/STERILIZE PERPOSE SIZE-2FTX1FT 166 Recess mounted sealed IP54 Protocol, non-hygroscopic UV peripheral lights ( 1 x 2 ) having compact high glow low wattage LED lighting system. These lights are having electrical safety code for high & low voltages.The luminaries for recess mounting in operation theatres should flush with the ceiling based on LED. Ultraviolet (UV) lamps are commonly used in operation theatres for disinfection.Luminaries cover made of highly-resistant, disinfectant-proof acrylic diffuser with white coated frame.Closing devices are integrated automatically in the electrical safety control without lines having to be connected to the luminaries housing. Luminaries’ body made of sheet steel, white, powder-coated, supplied ready for connection optionally for individual or group with power saving technology. Luminaries with protection IP 65, and protection class I,230 V,50 Hz.Recess frames for the gas-tight installation of clean-room luminaries in IP 65 in suspended ceilings.Frame made of extruded aluminium profile, white, powder-coated, able to be put together to form a rigid, continuous frame by means of plug and screw connections.Make- Altos/Dgline or Equivalent 167 Surgical Scrub Station – Two Bay 168 Compact surgical scrub sink should be designed for use in OT complex providing for pre – OT scrub up. Each fixture should be fabricated from heavy gauge type 304 stainless steel and should be seamless welded construction, polished to a satin finish.The washing faucet shall be made of Chrome plated brass hand. The station shall be equipped with soap dispensers made of SS 304 grade.The scrub sink should be provided with a front access panel which should be easily removed for access to the water controlled value, waste connections, stoppers and strainers.Hands free operation should include infra red sensors with built-in range of adjustment.The scrub station shall be made of high-grade stainless steel 304 with stain polish finish and wired to the current IEE regulations & BS 7971.Thermostatic mixing, valve control should be located behind the access panel and maintain constant water temperature. User defined setting of 1,3,6 & 10 min should be available. This timing should be adjustable to meet individual application requirements.All units should have reduced anti- splash fronts.The scrub stations control system shall be based on advanced microprocessorThe scrub station shall be sensor-activated 24VAC and should have the provision to operate it manually in case of power failure by using foot switch or knee switchimported thermostatic mixing valve for Hot & Cold water, Strainers, Spouts & manual foot operated valve system.Make- Jindal/Tata or Equivalent 169 AUTOMATIC PHASE SEQUENCE CONTROLLER 170 PMC Based (Pre magnetic Contractor)63A Double interlock & time Delay systemAuto/Manual Operation Sie- 140 x 275 x 320 mm Smooth and fasr Switchingworks well even at high & low voltages. Wide Current rnge.Voltage Range-130-280Vac Temperature- 55 Degree Celsius Auto mode Selector switchDigital micro Control relay for sequence management.LED Indicator for complete status of power.Make- Subtech or Equivalent 171 Operation Theatre Light - LED type, Camera Ready (Triple Arm) 172 Operating Room Surgical Lighting system should provde an ideal combination of broghtness, maneuverability, and shadow resolution without sacrificing color accuracy throuh a consistent LED technology. Such Lighting System should have the following technical specifications: 173 a. Number of light heads : Two per suspensionb. Colour Temperature range : 3800k-5000 (±10%) - Variable color temperature. c. Field Size Diameter : 20 to 28 cm (+/- 10%)d. Working range : 750 to 11100 mm (+/- 10 %)e. Illumination Level : 160000Lux (major Dome & Minor dome )f. Rotation : 360 - 330 degree g. Sterilizable Handle : 02 Nos h. Mounting type : Ceiling i. Supply Voltage : 230 VAC 50 Hz j. Bulb Type : LEDk. Dimming Range : 50% - 100%l. Operating / Storage Humidity : 10 - 95 %m. Life of Light source : > 40,000 Hrs n. Should be provision to mount the camera in 1 dome . o. Surgical Light System Should be compliant with relevant European CE / US FDA standardsMake- HillRom/Steris orEquivalent 174 GST Extra as applicable
Disclaimer
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tender Detail
| Website | https://etender.cpwd.gov.in/login.html |
| Quantity | |
| MSME Exemption | No |
| Tender Type | Open Tender |
| Startup Exemption | Click Here |
| Competitive Bidding | NCB |
TENDER INSIGHTS
858
Electric TendersLive
Tell us about your Product / Services,
We will Find Tenders for you