TDR : 55305318
Gujarat Energy Transmission Corporation Limited

Tender Brief :

Navsari, Gujarat

Tender For Work of Mechanical strengthening- Conductor, Hardware replacement of 66 KV D/C line on same tower (1) Sultanpur- Amalsad Line and (2) 66 KV Sultanpur- Abrama line from location no.9 to 19 under Navsari AM division.

Published: Ref Document
Opening: Ref Document
Closing: 21 Jul 2026
Amount: 5.24 Lakhs
EMD: 5243
Tender Fee: 590


Works Active Harmonic Filter Actuator Aerial Cable Aerodrome Beacon Air Circuit Breaker
9
Days Left
Tender Summary / Eligibility Criteria
Work of Mechanical strengthening- Conductor, Hardware replacement of 66 KV D/C line on same tower (1) Sultanpur- Amalsad Line and (2) 66 KV Sultanpur- Abrama line from location no.9 to 19 under Navsari AM division.
Documents Download All
1
1.TCNSETRM09202627.pdf
9690a5fc8c7f401d9f697c4035e8db5b
9690a5fc8c7f401d9f697c4035e8db5b.html
No Boq
Sr No Corrigendum Date Corrigendum Type New Submission Date
1 22-05-2026 30-06-2026
2 30-06-2026 21-07-2026
Probable Bidders

AI engine predicts probable bidders to help you bid strategically.

MSME Exception
Explore More →
Technical
Tender involves procurement of high capacity electrical equipment including diaphragm coupling of pump & motor with 90kW capacity at 2900 RPM. The project scope includes installation, testing, commissioning and operational handover.
Previous / Similar Result
BRR : 4296789 Bids Are Invited For OPERATION AND MAINTENANCE OF ELECTRICAL AND MECHANICAL INSTALLATIONS, 1 Sub-Head A (Operation and Maintenance)Periodical Operation and Maintenance of various Electrical and Mechanical Installations of Terminal Building, ATC Tower, Fire station including AC Operation, Pump Operation, Fire Fighting and alarm systems operation, GLF operation and other ancillary buildings including operation, repairs and maintenance, attending faults / breakdown rectifications, ensuring serviceability / satisfactory working conditions of the system, attending complaints, preventive maintenance and maintenance of records / documentation etc. as per tender specifications, terms and conditions covered under this contract on all days including Saturdays, Sundays and holidays by providing following minimum manpower as per requirement in general shift per day.(a) Skilled Manpower(Electrician/Technician)-02 Nos. (Reliever Shall be Provided on Weekly Off/Holiday)(b) Unskilled Manpower(Helper -02 Nos. (Reliever Shall be Provided on Weekly Off / Holiday).Note-Contractor has to provide Reliever on Weekly Offs / Holidays of above required staffs. 2 Periodical Operation and Maintenance of various Electrical and Mechanical Installations of Sub-Station i/c repairs and maintenance, attending faults / breakdown rectifications, ensuring serviceability / satisfactory working conditions of the system, attending complaints, preventive maintenance including operation of DG sets of different capacity and maintenance of records / documentation etc. as per tender specifications, terms and conditions covered under this contract on all days including Saturdays, Sundays and holidays by providing following manpower as per requirement for round the clock operation in three shifts per day.(a) Skilled (Electrician/Technician)-03 Nos. (i.e. 01 No. in each shift for round the clock operation and Reliever Shall be Provided on Weekly Off/Holiday)(c) Unskilled(Helper) - 03 Nos. (i.e. 01 No. in each shift for round the clock operation and Reliever Shall be Provided on Weekly Off/Holiday)Note- Contractor has to provide Reliever on Weekly Offs / Holidays of above required staffs. 3 Sub-Head B (Misc RandM works)Annual Comprehensive maintenance of Inverter / Non- Inverter Split type room Air conditioner Units of following capacity, different makes including stabilizer (If any) installed at different locations inclusive of all spares, materials involving repair and maintenance as per manufacture schedule, servicing including routine preventive maintenance, breakdown maintenance including repair/replacement of compressor, electronic circuit board, mechanical, equipment, safety controls and instrumentations gas charging, fan, fan motors, thermal Insulation, etc. ensuring serviceability/ satisfactory working condition of the system, maintenance of recordes/documentation etc. as per tender conditions covered under this contract on all days including Sunday and holiday etc. as required..2.0 TR, 1 Phase, 230 V, 50 Hz Split AC Unit (1st Year) 4 Annual Comprehensive maintenance of Inverter / Non- Inverter Split type room Air conditioner Units of following capacity, different makes including stabilizer (If any) installed at different locations inclusive of all spares, materials involving repair and maintenance as per manufacture schedule, servicing including routine preventive maintenance, breakdown maintenance including repair/replacement of compressor, electronic circuit board, mechanical, equipment, safety controls and instrumentations gas charging, fan, fan motors, thermal Insulation, etc. ensuring serviceability/ satisfactory working condition of the system, maintenance of recordes/documentation etc. as per tender conditions covered under this contract on all days including Sunday and holiday etc. as required..2.0 TR, 1Phase, 230 V, 50 Hz Split AC Unit (2nd Year) 5 Annual Comprehensive periodical maintenance of VRV type outdoor Air conditioner Units of Following capacity, and Cassette type indoor units of Daikin makes, Model No. RXYQ20ARY6 (5Nos. VRV Unit Each 20HP 3Phase, 380-415V, 50 Hz, with 20 Nos. Indoor Cassette type units) installed at terminal building inclusive of all spares, materials involving repair and maintenance as per manufacturer schedule, servicing including routine preventive maintenance, breakdown maintenance including repair/replacement of compressor, electronic circuit board, mechanical, equipment, safety controls and instrumentations gas charging, fan, fan motors, thermal Insulation, etc. ensuring serviceability/ satisfactory working condition of the system, maintenance of recordes/documentation etc. as per tender conditions covered under this contract on all days including Sunday and holiday etc. as required.(Maintenance to be done through OEM/Authorized dealer/specialized agency.)Model No. RXYQ20ARY6 (5Nos. VRV Unit Each 20HP 3Phase, 380-415V, 50 Hz, with 20 Nos. Indoor Cassette type units)-(1st Year) 6 Annual Comprehensive periodical maintenance of VRV type outdoor Air conditioner Units of Following capacity, and Cassette type indoor units of Daikin makes, Model No. RXYQ20ARY6 (5Nos. VRV Unit Each 20HP 3Phase, 380-415V, 50 Hz, with 20 Nos. Indoor Cassette type units) installed at terminal building inclusive of all spares, materials involving repair and maintenance as per manufacturer schedule, servicing including routine preventive maintenance, breakdown maintenance including repair/replacement of compressor, electronic circuit board, mechanical, equipment, safety controls and instrumentations gas charging, fan, fan motors, thermal Insulation, etc. ensuring serviceability/ satisfactory working condition of the system, maintenance of recordes/documentation etc. as per tender conditions covered under this contract on all days including Sunday and holiday etc. as required.(Maintenance to be done through OEM/Authorized dealer/specialized agency.)Model No. RXYQ20ARY6 (5Nos. VRV Unit Each 20HP 3 Phase, 380-415V, 50 Hz, with 20 Nos. Indoor Cassette type units)- (2nd Year) 7 Supply and laying of refrigerant copper piping including top up of gas charging suitable for 1.5TR / 2TR / 2.5TR capacity of different type AC Units, both suction and discharge along with suitable thermal Insulation and suitable necessary accessories for connection complete for shifting/ reinstallation of ACs as per site requirement. (One lengths of suction, discharge piping and length of copper wire shall be measured one meter for this item)1st Year 8 Supply and laying of refrigerant copper piping including top up of gas charging suitable for 1.5TR / 2TR / 2.5TR capacity of different type AC Units, both suction and discharge along with suitable thermal Insulation and suitable necessary accessories for connection complete for shifting/ reinstallation of ACs as per site requirement. (One lengths of suction, discharge piping and length of copper wire shall be measured one meter for this item)2nd Year 9 Annual comprehensive maintenance of water cooler ( Make- Voltas Model- No. VOLTAS WC FS 40/80NP ) installed at terminal building, inclusive of all spares, materials involving repair and maintenance as per manufacturer schedule, servicing including routine preventive maintenance, breakdown maintenance including repair/replacement of compressor, electronic circuit board, mechanical, equipment, safety controls and instrumentations, gas charging etc. ensuring serviceability/ satisfactory working condition of the system, maintenance of recordes/documentation etc. as per tender conditions covered under this contract, providing all necessary consumables complete as required.1st Year 10 Annual comprehensive maintenance of water cooler ( Make- Voltas Model- No. VOLTAS WC FS 40/80NP ) installed at terminal building, inclusive of all spares, materials involving repair and maintenance as per manufacturer schedule, servicing including routine preventive maintenance, breakdown maintenance including repair/replacement of compressor, electronic circuit board, mechanical, equipment, safety controls and instrumentations, gas charging etc. ensuring serviceability/ satisfactory working condition of the system, maintenance of recordes/documentation etc. as per tender conditions covered under this contract, providing all necessary consumables complete as required.2nd Year 11 Annual comprehensive maintenance for RO System( Make, Kent ELITE PLUS) upto 50 litre capacity including replacement of all defective components and carrying monthly service activity as required. The supply of consumable spares, membrane and filters as mentioned in item 8 is not included in the scope of this item. 1st Year 12 Annual comprehensive maintenance for RO System (Make, Kent ELITE PLUS) upto 50 litre capacity including replacement of all defective components and carrying monthly service activity as required. The supply of consumable spares, membrane and filters as mentioned in item 8 is not included in the scope of this item. 2nd Year 13 Rewinding, servicing, repairing of following fans including replacement of worn-out/ defective parts like copper wire, insulation, bearings, capacitors etc., i/c transportation from site to workshop and back to site. (dismantled material/ wire shall be property of tenderer)Ceiling Fan 14 Rewinding, servicing, repairing of following fans including replacement of worn-out/ defective parts like copper wire, insulation, bearings, capacitors etc., i/c transportation from site to workshop and back to site. (dismantled material/ wire shall be property of tenderer)Wall Fan / Pedestal fan 15 Rewinding, servicing, repairing of following fans including replacement of worn-out/ defective parts like copper wire, insulation, bearings, capacitors etc., i/c transportation from site to workshop and back to site. (dismantled material/ wire shall be property of tenderer)Exhaust Fan 16 Lifting and lowering of borewell submersible pump of various capacities (up to 3 HP) due to defect in existing pump on urgent basis within a short notices including connection of cables jointing of cables etc. with successful testing and commissioning complete as required. 17 Repair and rewinding of following capacity single phase submersible pump motor sets. Job include transportation of motor dismantling and rewinding with the same gauge insulated copper wire including replacement of all the internal worn out / defective parts i.e. bushes, impellers, sleeves, upper and lower bushes sets, thrust bearing, oil seals, rotor grinding and balancing, assembling, testing, transportation etc. complete as required. (dismantled material/ wire shall be property of tenderer)1HP 18 Repair and rewinding of following capacity single phase submersible pump motor sets. Job include transportation of motor dismantling and rewinding with the same gauge insulated copper wire including replacement of all the internal worn out / defective parts i.e. bushes, impellers, sleeves, upper and lower bushes sets, thrust bearing, oil seals, rotor grinding and balancing, assembling, testing, transportation etc. complete as required. (dismantled material/ wire shall be property of tenderer)3HP 19 Refilling of fire extinguisher and Hydraulic pressure Testing (HPT) from authorized center as per Norms of following type and capacity as and when required.CO2 Type- 4.5KG Capacity 20 Refilling of fire extinguisher and Hydraulic pressure Testing (HPT) from authorized center as per Norms of following type and capacity as and when required.CO2 Type- 6.5KG Capacity 21 Refilling of fire extinguisher and Hydraulic pressure Testing (HPT) from authorized center as per Norms of following type and capacity as and when required.ABC Type 4KG Capacity 22 Refilling of fire extinguisher and Hydraulic pressure Testing (HPT) from authorized center as per Norms of following type and capacity as and when required.ABC Type 6KG Capacity 23 Refilling of fire extinguisher and Hydraulic pressure Testing (HPT) from authorized center as per Norms of following type and capacity as and when required.ABC Type 5KG Capacity 24 Dismantling of high wall split type air conditioning unit , re-installation, testing and commissioning of capacity up to 2 TR. air-conditioner units , fixing of existing refrigerant pipe, insulation and existing flexible copper conductor cable between evaporator and condenser units, topping up refrigerant gas etc. complete as required. 25 Servicing of Land T Make, Model- CN-CS 800S1 Air circuit breaker 800 Amp through authorised service dealer of OEM/ specialized agency including carrying out of following works racking out and removal of ACB from switch board, cleaning all parts for dust deposits foreign particles etc , degreasing the various parts of ACB. Cleaning all parts with cleaning agents such as CRC 2-26 checking the various settings within the ACB of contacts, releases etc, checking the hardware for wear and tear, checking of termination and tightness, checking for all hardwares for its presence, replacement of spares / accessories for defective / worn out items (Supply of spares / accessories required for healthiness of ACB are in AAI scope), regreasing of the ACB parts as recommended by OEM, refixing the ACB, testing and observance for normal operation of ACB complete as required. 26 Servicing/maintenance of existing 11 KV VCB panel (installed in HT panel room- Panel Type- AES1220VCBP-1D, Sr. No.1-1346-5, Mfg Year 2019 ) as per recommendation of OEM / Authorized dealer of OEM/ specialized agency. 27 Testing for healthiness and carrying out calibration of all relays i/c secondary injection test installed in 11KV HT panel of sub-station and submission of test report and calibration certificate as required. Details of HT panel Panel is - AES1220VCBP-1D, Sr. No.1-1346-5, Mfg Year 2019.Note- Testing and callibrations to be done by OEMs recommended callibrated Kit, by their Er./Technician or by Er./Technician of Authorized dealer of OEM/ specialised agency. 28 Topping up transformer oil including oil filtration/ dehydration and oil sample testing of 500 KVA 11/0.415kv transformer of Make- KOTSONS PRIVATE LIMITED, Serial No. 20190182 Mfg Year 2019. 29 Oil sample Testing of Transformer oil for 500 KVA 11/0.415kv transformer of Make- KOTSONS PRIVATE LIMITED, Serial No. 20190182 Mfg Year 2019 etc. complete as required. 30 Oil filtration and Dehydration i/c oil sample testing before and after of dehydration of 500 KVA 11/0.415kv transformer of Make- KOTSONS PRIVATE LIMITED, Serial No. 20190182 Mfg Year 2019. 31 Annual Maintenance of Micro Processor controlled CCRs of NASU make including repairing of defective CCRs by identifying the fault, replacement of defective PCBs and other components and service the same, including calibration/checking of the protection circuits, insulation monitor circuits and brightness controls of MPCCRs and complete checking, servicing on quarterly basis etc. as required as per the directions of Engineer-in-Charge and submission of test reports etc as per manufacturer recommendations of NASU make (All the components required for servicing of MPCCRs will be provided by AAI). 4 KW, Microprocessor Controlled Nasu Make CCRSr. No. NS/MPCCR/09/2019/09- (1st Year) 32 Annual Maintenance of Micro Processor controlled CCRs of NASU make including repairing of defective CCRs by identifying the fault, replacement of defective PCBs and other components and service the same, including calibration/checking of the protection circuits, insulation monitor circuits and brightness controls of MPCCRs and complete checking, servicing on quarterly basis etc. as required as per the directions of Engineer-in-Charge and submission of test reports etc as per manufacturer recommendations of NASU make (All the components required for servicing of MPCCRs will be provided by AAI).4 KW, Microprocessor Controlled Nasu Make CCRSr. No. NS/MPCCR/09/2019/10- (1st Year) 33 Annual Maintenance of Micro Processor controlled CCRs of NASU make including repairing of defective CCRs by identifying the fault, replacement of defective PCBs and other components and service the same, including calibration/checking of the protection circuits, insulation monitor circuits and brightness controls of MPCCRs and complete checking, servicing on quarterly basis etc. as required as per the directions of Engineer-in-Charge and submission of test reports etc as per manufacturer recommendations of NASU make (All the components required for servicing of MPCCRs will be provided by AAI). 4 KW, Microprocessor Controlled Nasu Make CCRSr. No. NS/MPCCR/09/2019/09- (2nd Year) 34 Annual Maintenance of Micro Processor controlled CCRs of NASU make including repairing of defective CCRs by identifying the fault, replacement of defective PCBs and other components and service the same, including calibration/checking of the protection circuits, insulation monitor circuits and brightness controls of MPCCRs and complete checking, servicing on quarterly basis etc. as required as per the directions of Engineer-in-Charge and submission of test reports etc as per manufacturer recommendations of NASU make (All the components required for servicing of MPCCRs will be provided by AAI).4 KW, Microprocessor Controlled Nasu Make CCRSr. No. NS/MPCCR/09/2019/10- (2nd Year) 35 Annual maintenece of remote control desk including repairing of the control desk by identifying faults i/c replacing defective components,servicing the same , doing preventive mainlenance , keeping the system in working condition by carrylng out preventive maintenance every quarter. (All the components required for servicing of RCD will be supplied by AAl )1st Year 36 Annual maintenece of remote control desk including repairing of the control desk by identifying faults i/c replacing defective components,servicing the same , doing preventive mainlenance , keeping the system in working condition by carrylng out preventive maintenance every quarter. (All the components required for servicing of RCD will be supplied by AAl )2nd Year 37 Servicing and maintenance i/c calibration and stamping of 200kg Electrical Weight Machine , Stamping to be done from Government Legal metrology once in year and servicing once in six Month as required.1st Year 38 Servicing and maintenance i/c calibration and stamping of 200kg Electrical Weight Machine , Stamping to be done from Government Legal metrology once in year and servicing once in six Month as required.2nd Year Total Quantity : 201587
Contract Date : Ref. Documents   |   Contract Value : 74.48 Lakhs
BRR : 10578906 Supply, Erection, Installation And Commissioning Of Material Equipment For The Work Of Release Of Ag Connection In Fy 2022-23 On Turnkey Basis In Respect Of Bharatpur Circle Lot-I Under The Domain Of Jaipur Discom Against Tn-523 Supply of material (All material shall be supplied as per specification enclosed with the bidding documents):- 2 9 Mtr. LONG PCC POLES OF 200 KG WORKING LOAD WITH FACTOR OF SAFTY 2.5. 3 33 KV S/C LATTICE STRUCTURE (36 UNGALVANISED WITH 1 NOS 33 KV CROSS ARM(CHANNEL) WITH REQUIRED NUTS AND BOLTS. 4 11/0.433 KV, 40 KVA ALUMINIUM WOUND BIS LEVEL-2 COMPLETELY SELF PROTECTED (CSP) DISTRIBUTION TRANSFORMERS WITH PROVISIO OF LT BUSHING BOX 5 25 KVA, 11/0.433 KV, ALUMINIUM WOUNDBIS LEVEL-2 (STAR-1) COMPLETELY SELF PROTECTED (CSP) DISTRIBUTION TRANSFORMERS WITH PROVISION OF LT BUSHING BOX. 6 16 KVA, 11/0.433 KV, ALUMINIUM WOUNDBIS LEVEL-2 (STAR-1) COMPLETELY SELF PROTECTED (CSP) DISTRIBUTION TRANSFORMERS WITH PROVISION OF LT BUSHING BOX. 7 GALVANISED STEEL STAY SET 16x1800 MM 8 11 KV STAY INSULATOR 9 GALVANISED STEEL STAY WIRE 7/10 SWG 10 STAY SET CLAMPS SUITABLE FOR 9 MTR. LONG PCC POLES 11 H/W FOR DISC INSULATORS 45KN T&C TYPE 12 DISC INSULATORS 45KN T&C TYPE 13 M.S. NUTS & BOLTS (ASSORTED SIZE) 14 ACSR RABBIT CONDUCTOR 15 11 KV V CROSS ARM WITH TOP HAMPER AND CLAMPS ( ANGLE) 16 GALVANIZED M.S. FROGED 11 KV PIN 17 11 KV PIN INSULATOR 18 11/0.4 KV S/S STRUCTURE SET FOR 3-PH 40/25/ 16 KVA TRANSFORMER ON DOUBLE POLE 19 HORN GAP FUSE SET WITH POST INSULATOR 11 KV 20 MS ROD TYPE EARTHING SET WITH WIRE & CLAMP with following details(1 No.- Galvanised M.S. Rod 20 mm dia electrodes having3 Meter length, 2 Nos.- Galvanised Earthing clamp of M.S.Flat of size 50x6 mm 220 mm length. One welded with earthelectrode and loose to be bolted; 2 Nos.- Galvanised Bolts, Nuts and Spring washers and G.I.Wire Size 8 SWG of 15 Meter length) 21 1.4 MTR CHANNEL 100x50x6 MM BRACKET WITH CLAMP 22 4C X 16 SQ. MM. LT PVC INSULATED PVC SHEATHED CABLE (ARMOURED) 23 M.S. ANGLES 75 X 75 X 6 MM (FOR GUARDING) 24 THREE PHASE FOUR WIRE WHOLE CURRENT METER OF RATING 10-60 A HAVING BACKLIT LCD DISPLAY WITH METER BOX (FREE ISSUE). 25 M.S. CHANNEL 75 X 40 X 6 MM (FOR EXTENSION BRACKET) 26 LT SHUNT CAPACOTORS 3 KVAR 27 LT SHUNT CAPACOTORS 6 KVAR 28 DANGER PLATE 29 11 KV LINE DP SET 30 P.G. CLAMPS FOR RABBIT 31 G.S. EARTH WIRE 8 SWG 32 Erection of material:- 33 Trimming of tree branches/plants and preparing route approchases for proposed line. 34 Excavation of pit in Hard soil to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit. 35 (A) Height of poles/R.S.Joist/M.S. Rail /Size of pit 36 9 Mtr/ 1.2mx0.6mx1.50 m deep 37 (B) Lattice Tower /Size of pit 38 11.4/10.8 Mtr/ 1.5mx1.5m x1.80 m deep 39 (C)Stay set/Depth of pit 40 6x5/8-0.75x0.5x1.35m 41 Excavation of pit in ordinary rock which does not require blasting to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit. 42 (A) Height of poles/R.S.Joist/M.S. Rail /Size of pit 43 9 Mtr/ 1.2mx0.6mx1.50 m deep 44 (B) Lattice Tower /Size of pit 45 11.4/10.8 Mtr/ 1.5mx1.5m x1.80 m deep 46 (C)Stay set/Depth of pit 47 6x5/8-0.75x0.5x1.35m 48 Safe carriage of PCC poles including loading / un-loading 49 c) 9 Mtr.long 200 Kg. PCC pole 50 within10 Kms.- 51 Above 10 Km. & upto 30 Km. add foreach Km. or part thereof 52 Above 30 Km. add for each Km. or part thereof (50 KM) 53 Safe carriage of steel( fabricated and unfabricated) I.e.M.S. Rails, R.S.Joists, M.S.Channels, M.S.Angles, M.S.Flat, G.I.Stay Sets, G.I. Stay Wire, G.I.Wire Nut & Bolts etc. and ACSR Conductor including loading and unloading and stacking in Nigam store /at work site 54 Within10 Kms. 55 Above 10 Kms. & upto 30 Kms. Add for each Km.or part thereof. 56 Above 30 Kms. Add for each Kms. or partthereof. (50 KM) 57 Safe Carriage of insulator, hardware, cable etc.including loading/unloading and stacking in Nigam.stores etc. 58 Within10 Kms. 59 Above 10 Kms. & upto 30 Kms. Add for each Km.or part thereof. 60 Above 30 Kms. Add for each Kms.or part thereof. (50 KM) 61 Safe carriage of fabricated lattice towers structures and sub-station structures type AB, AB beams, isolators structures etc. including loading/unloading and stacking in the Nigam. Stores / at work site. 62 Within10 Kms. 63 Above 10 Kms. & upto 30 Kms. Add for each Km.or part thereof. 64 Above 30 Kms. Add for each Kms.or part thereof.(50 KM) 65 Safe Carriage of 11/.4 KV 3 Phase distribution transformer including loading/unloading and stacking in Nigam.stores etc. 66 10 &16 kva 67 Within10 Kms. 68 Above 10 Kms. & upto 30 Kms. Add for each Km.or part thereof. 69 Above 30 Kms. Add for each Kms.or part thereof. (50 KM) 70 25 & 40 kva 71 Within10 Kms. 72 Above 10 Kms. & upto 30 Kms. Add for each Km.or part thereof. 73 Above 30 Kms. Add for each Kms.or part thereof. (50 KM) 74 Erection of all type of steel supports in the excavated pit in alignment after checking the same with plumb line including fixing of cross arms and top hamper before erecting the supports. The support should be grouted and muffed in cement concrete of ratio 1:3:6 as per item No. 5.6 the remaining portion of the pit will be back filled with soil. The nuts & bolts will be provided by the contractor as per Nigams specification for which payment will be made at the prevailing store issue rates. The cost muffing and grouting will be paid extra. 75 Lattice Structure 76 Erection of PCC poles in excavated pit with fixing of brackets,cross arms & top hampers as required in alignment after checking the same with plumb line. The support is to be back filled with soil with proper ramming. The nuts & bolts are to be provided by the contractor as per Nigams specification for which the payment will be made at the prevailing Discom store issue rates. 77 IN RURAL AREA 78 PCC Poles 9 Mtr. Long(200Kg.) 79 Erection & assembly of 2 pole structures ofof steel supports or of PCC poles in excavated pit in alignment afterchecking the same with plumb line. Including fixing of top bracing of m.s. channels with pilot plates and clamps. The support is to be back filled with soil with proper ramming. The nuts & bolts are to be provided by the contractoras per Nigams specfication for which the payment will be made at the prevailing Discom store issue rates. 80 PCC Poles 9 Mtr. Long(200Kg.) 81 Erection & fixing of G.I.Stay sets with anchor plates in excavated pit in required position and back filling with soil with proper ramming.The work includes fixing of stay clamps. Stay insulator with stay wire at both ends with proper tension.Size of stay set/stay wire 82 6x5/8 with 7/10 SWG stay wire 83 Providing and laying of cement concrete in ratio 1:3:6 using 43 grade cement,river sand and 12 mm to 20 mm graded blast crusher broken in pit/foundation according to the size/type of supports/stay set including compaction/curing for 21days in steel plates shuttering /farmer base.(1.2X1.2 x2.1 M)/Tower 84 Fixing of all type of fabricated material on erected supports with nut & bolts as per approved design & drawing of sub-station. 85 Fixing of guarding Bracket arms with clamp on erected support as per design. The nuts &bolts will be supplied by the contractor as per Nigams specification for which payment will be made as per prevailing Discom store issue rates. 86 11 KV line 87 Fixing of earth wire clamp on erected supportas per design. The nuts &bolts will be supplied by the contractor as per Nigams specification for which payment will be made as per prevailing Discom store issue rates. 88 Fixing and assembly of disc.point channel pair with pilot plates&clamps on erected double pole structure as per design. The nuts &bolts are to be provided by the contractor as per Nigams specification for which payment will be made as perprevailing Discom store issue rates. 89 11 KV line 90 Fixing and assembly of disc. Point channel pair with pilot plates & clamps on erected Single pole structure as per design. The nuts & Bolts are to be Provided by the contractor as per Nigams specification for which payment will be made as per prevailingDiscom store issue rates. 91 11 KV Line 92 Fixing of 11kv B&S/T&C type disc insulator of 11kv lines(each unit consiting of 1nos.disc.& 1set of H/ W ) on terminal point including fixing of hardware and strips. 93 Fixing of 11 KV pininsulator with pins. 94 ssembly and installation of Horn Gap fuse set (set of 3 Nos)on erected structure as per design, complete in all respectwith post insulator includingjumperingonbothendsforconnection with the system. The nuts & bolts will be supplied by the contractorfor which payment will be made as per prevailing Discom store issue rates. 95 11kv Horn Gap fuse set. 96 Installation testing as per Nigams norm & commissioning of11/0.4 kv distribution transformer on erected supports including fixing of base channels as per requirement jumpering on HV&LV side, crimping of lugs/clamping earth connections of body and neutral of transformer with wire/strip (as already provided with earthing) complete in all respect. The PG clamps nuts & Bolts will be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates. 97 10 & 16 KVA 98 25 & 40 KVA 99 Fixing of danger plates on supports/structure 100 Fixing of PG clamp of Weasel /Rabbit Conductor 101 Laying, Jointing , Stringingtensioning and clamping of conductor with proper sag as directed, using bolted type hardware including binding on pin insulators, jumpering on section points with binding wire/P.G. clamps Aluminium jointing sleeves will be used for jointing the conductor. The line must stand at proper voltage on charging. The contractor will be provide P.G. clamps for which payment will be made as per prevailing Discom store issue rates. 102 ACSR RABBIT 103 Laying, jointing,stringing,tensioning and clamping of G.I.Earthwire continuosly on single/double pole by using earth clamps /nuts & bolts with washers and earth reel etc.including proper binding at each end.The nuts and bolts will be supplied by thecontractor for which payment will be made as per prevailing Discom store issue rates. 104 (B) IN RURAL AREA 105 G.I.Earth wire 8 SWG 106 Drawing & strining of G.I 4 wire over the guarding brackets for guarding of road crossing /P&T crossing/railway track crossing (for one span only)with cross G.I wire laces at an intraval of two meter each or required as per location using EYE bolt Nuts. 107 8 SWG with laces of 10 SWG 108 Earthing of line for all type of supports as per REC construction standards using Stay wire/GI wire with one pcs of M.S. rod 20mm dia each 3 meter long and driving into earth by mechanical means MS rod, MS flat & stay wire will be supplied by the contractor. Ifmaterial is supplied by the contractor the payment will be made as per prevailing Discom store issue rates.(in case of PCC Poles earthing mustbe connected with earthwire already available on PCC Pole at bottom) 109 Earthing of 11/0.4 KV distribution transformer /sub-station with 3 pieces of M.S. Rod 20 mm dia each 3 meter long and drivingthem in to earth by mechanical means at a distance as per approved design & drawing & specification. The work includes flattening of top ends of M.S. Rod drilling a hole of 9/16 dia. At Flattened top and tightening of M.S. flat 50x6mm (having 3 hole 2ends and 1mm middle) with nuts and bolts with m.s. rod. Top end hole. The flat will also be welded with M.S. rod. The end will be connected to equipments as under as under in sequence. 110 Fixing of three phase meter cummeter box(complete unit)at the premises of existing/new consumerswith 4 Nos Anchor fastners with rust proof size M-6x50 mm on the wall as per the positionof holes already provided on the meter box. The meter box must be housed perfectly vertical/plumb line,anchor fasteners are to be supplied/provided by the contractor including safe carriage from S/D store to consumers site and depositing removed meter and meter box if any in S/D store). 111 IN RURAL AREA 112 Laying of 1100 volt heavy duty armoured XLPE cable of aluminum coudctor of following size conforming to IS: 7098 (Pt-I) (latest amended) overhead service line from pole to meter terminals for release of new LT connections/replacement of damaged/obsolete service line (except agriculture one). The cable must be fixed on wall with clamps /hooks properly at a interval of one meter. 113 4 Core 16/25 sq. mm 114 fixing of 3 phase LT shunt capacitor (3/6/9/12KVAR) near starterof motor for agriculature consumers to be fixed with MS clamp of -shape of size 2x10mm having two nos.holes for fixing of LT capacitors besides starter of consumer with the help of two no.machine screw. The starter shall be connected using PVC sheathed single core of 4 sq.mm AI. cable conforming to relevant IS. The wire shall be cut in three pieces which shall be used for extending existing wire whith making proper joint and joint shall be taped with MS compoundPVC tape roll. The ends of wire shall be properly crimped with lugsthimble etc.All material shall be supplied by the contractor except LT shunt capacitor (The LT shunt capacitor shall be supplied by Nigam)
Contract Date : Ref. Documents   |   Contract Value : Ref. Documents
BRR : 9526497 Tender For Special Repair To Smq P 101 At Af Stn Kasauli Under Ge Kasauli; 2 Demolition ofcement concrete (reinforced) in Roofs, floors (other than ground floors), beams, staircases, landing, chajjas, and similar suspended workand removing rubbish/ demolished material outside defence land, complete all as specified and as directed . 3 Material and Labour for form work chulla hoods, chajjas, troughs and similar items including edges for fair finished surface of concrete, complete all as specified. 4 Material and Labour TMT steel bars of 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete, all as specified and as directed. 5 Material and labour for providing reinforced cement concrete 1:2:4 type B0 (using 12.5mm graded mechanically crushed stone aggregate)as chajja, fins, louvers, roof projection ,beam and lintel after removing of all loose concrete andloose plaster, cleaning surface with wire brush to remove all dust/dirt/loose particles to expose old steel reinforcement, applying derusting chemical on exposed steel surfacesuch as Dr fixit rust remover or equivalent and welding additional main bars/distribution bars by insertingto adequate depth in beam, chajjas, etc. complete, all as specified and as directed.Note- 1.The work will be carried out at a height upto 9 metre and necessary scafolding required in the work included in the quoted rate under this item.2.Reinforcement will measured and pid separately. 6 Material and labour rendering 5 mm thick on fair faces of brick work or concrete ceiling or chajjassurfaces in cement mortar 1:3 andfinishedeven and smooth without using extra cement and applyingtwo coats of cement based paint after preparation of newly plastered surfaces of ceiling complete all as specified and as directed.Note- 1.The work will be carried out at a height upto 8 metre and necessary scafolding required in the work included in the quoted rate under this item. 7 Taking down cement plaster of any description, thickness and in any position including raking out joints, hacking for key, scrubbing down with water etc , and removal the rubbish/ demolished material outside defence land, complete all as specified and as directed. 8 Material and labour for rendering 15 mm thick on surface of any description of brick work or concrete wall surfaces in cement mortar 1:4 mixed with water proofing compound @ 3% by weight of cement or as per manufacturers instruction and finished fair and even without using extra cement complete all as specified and as directed.( Note- The cost of providing WPC shall be included in quoted rate under this item). 9 Material andlabour for 10mm thick rendering in cement mortar (1:6)on surface of any description of brick or concrete and finished the surface even and smooth without using extra cement complete all as specified and as directed. 10 Material and labour for preparing new plastered or unplastered surfaces of walls and applying two coats of distemper oil emulsion, white or tinted over a coat of chalk whiteningcomplete all as specified and as directed. 11 Material and labour for preparation of new/old (plastered or unplasterd) surfaces of walls, applying 1 mm thick wall care putty white cement basedin two or more coats to achive smooth surfacesand applying two coats of exterior acrylic emulsion, anti weather abd anti algae paint (1st quality), in multi colour or as in(camouflage, if any) as approved, over and including a coat of alkali resistant primer, complete all as specified and directed.Note (s):-(i) Pattern of camouflage if any shall be as approved by GE.(ii)The work will be carried out at a height upto 8 metre and necessary scafolding required in the work included in the quoted rate under this item.(iii) Contractor shall carried out the painting work from the manufacturer of paint or his authorised applicators andalso submit 05 years gurantee certificate against fadding/Peeling of painting work to the department from manufacturer. 12 Material andlabour for complete removal of existing treatment on surfaces of walls by using appropriate technique as approved by Engr-in-chargefor complete removal of all layers of old treatment and reaching upto old plastered surface including filling up all cracks with Shalimar tar plastic (STP) crack filler and also, make good to plastered surface for the area n. exc. 0.01Square metre , if any and applying two coats ofoil bound distemperwith painting rollerover 1mm thick wall care putty white cement based in two or more coats to achive smooth surface over prepared surface complete all as specified and as directed. 13 Demolition of Brickwork or stone/ boulders masonry built in cement or cement lime mortar incl all quions, arches, pillars, etc but excluding ashlar facing, dressed stone work and precast concrete articles complete all as specified 14 Material and labourbrick work with sub class B old size bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6 complete all as specified and as directed by the Engineer-in-Charge. 15 Supply andfixing for bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required, hooks (stay), heavy, for large gates, hook and pintle hinges, large hasps and staples, chains, hand made sliding bolts, clamps, hold fasts, wall ties, wind ties, hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe-290-Gde E-165, complete all as specified and as directed. 16 Supply and fixing 1mm thick and 100mm dia angles (internal or external) or nozzle pieces (Out lets) complete all as specified and as directed. 17 Material and labour for preparation of new steel surfaces of any description over 10cm in width or girth not other wise described and applying two coats of synthetic enamel paint over a coat ofred oxide primer complete all as specified and as directed. 18 Supply and fixing 110mm diaUPVC, rain water drain pipe, type ‘A’ ,conforming toIS 13592-1992, single socketed, in any length with rubber rings joints or jointed with solvent cement joint, fixed to wall, complete all as specified anddirected.(Note- Rubber rings for pipes and fittings shall be confirm to IS 5382-1985) 19 Supply and fixing 110 mm bore UPVC (SWR) plain bend any radius including jointing with solvent cement, complete all as specified.(Note- UPVCbends shall be confirm to BS 4515 DIN 19531 and DIN 19534) 20 Supply and fixing for 110mm diaUPVC, soil waste drain pipe, type ‘B’ ,conforming toIS 13592-1992, single socketed, in any length with rubber rings joints or jointed with solvent cement joint, laid in trenches or in floors, complete all as specified anddirected.(Note- Rubber rings for pipes and fittings shall be confirm to IS 5382-1985) 21 Supply and fixingin repair, 75mm diaUPVC, soil waste drain pipe, type ‘B’ ,conforming toIS 13592-1992, double socketed, in any length with rubber rings joints or jointed with solvent cement joint, fixed to wallincluding all fittings, heads, shoes, bends, swan necks, etc. complete all as specified anddirected.(Note- Rubber rings for pipes and fittings shall be confirm to IS 5382-1985) 22 Supply and fixing PVC (SWR) reducers complete all as specified and directed.(Note- UPVCbends shall be confirm to BS 4515 DIN 19531 and DIN 19534) 23 Taking down wooden chowkats or frames area exceeding 1.50 Square metre andnot exceeding 4.00 Square metre (w/o taking off shutters from frames) including iron mongries and removing from site, including cutting holes for taking out existing hold fasts and making good the disturbed portion of jambs andadjoining surfaces to match with existing finish, complete all as specified and as directed. 24 Taking down wooden chowkats or frames areanot exceeding 1.50 Square metre(w/o taking off shutters from frames) including iron mongries and removing from site, including cutting holes for taking out existing hold fastsand making good the disturbed portion of jambs andadjoining surfaces to match with existing finish, complete all as specified and as directed. 25 Supply and fixing aluminium power coating of approved colour (Thickness or powder coating not less than 50 micron) in frame for doors, windows, ventilator shutters, aluminium with one or more rebates including necessary joining cleats, rubber packing, powder coated snap beading, glazing clips to recieve 5.5 mm thick tinted glass for glazing section, etc. complete all as specified complete all as specified and directedNote : The weight of Aluminium sectons shall not be less than 1.20Kg/Rm. 26 Supplying, fabricating and fixing of powder coated aluminium Windows, Triple Track having three sliding shutters(02 Glass and 01 Guazed) with followingpowder coated aluminium section with and including joining cleats, glazing clips, rubber packaging, snap beading and other necessary builders hardware as required, complete all as specified and as directed.[a] Top and side members for three track frame shall be of size 92.00 x 31.75 x 1.5 mm [b] Three track bottom rail of frame for sliding of shutter shall be of size 92.00 x 31.75 x 1.5 mm [c] Top and bottom rail of sliding shutter shall be of size 40 x 18 x 1.55 mm [d] Side rail of sliding shutter with handle and self locking arrangement section shall be of size 40 x 18 x 1.55 mm [e] Sliding shutter to be provided with 5.5mm thick Tinted Glass.[f] One shutter to be provided with stainless steel wire cloth 0.36mm dia and aperture 1.4mmNote :- (i) The weight of Aluminium sectons shall not be less than 1.2Kg/Rm. (ii) Thickness or powder coating shall not be less than 50 micron (iii) The door/window shall be as per drawings/directions of Engineer-in-charge and drawing may be reffered from GE office.(iv) The cost of Glass and wire mesh shall be included in the quoted rate against this item. 27 Supplying, fabricating and fixing Aluminium Windows, fourTrack, fabricated with powder coated aluminium sections with four sliding shutters(03 Glass and 01 Gazed) with following section including joining cleats, glazing clips, rubber packaging, snap beading and other necessary builders hardware as required all as directed by Engineer incharge : (Length of window more than 1.5M)[a] Top and side members for three track frame shall be of size 92.00 x 31.75 x 1.5 mm [b] Three track bottom rail of frame for sliding of shutter shall be of size 92.00 x 31.75 x 1.5 mm [c] Top and bottom rail of sliding shutter shall be of size 40 x 18 x 1.55 mm [d] Side rail of sliding shutter with handle and self locking arrangement section shall be of size 40 x 18 x 1.55 mm [e] Sliding shutter to be provided with 5.5mm thick Tinted Glass.[f] One shutter to be provided with stainless steel wire cloth 0.36mm dia and aperture 1.4mmNote :- (i) The weight of Aluminium sectons shall not be less than 1.20Kg/R,(ii) Thickness or powder coating shall not be less than 50 micron (iii) The door/window shall be as per drawings/directions of Engineer-in-charge and drawing may be reffered from GE office.(iv) The cost of Glass and wire mesh shall be included in the quoted rate against this item. 28 Supply and fixing Aluminium Powder Coated [Powder coating shall be 50 micron minimum thickness) Sections as in window and ventilator Shutters, Side hung type, without Sash Bar,including necessary Joining Cleats, Glazing Clips, Rubber Packing, powder coated snap beading, Screws, Aluminium fittings such as Peg Stays 150mm Long [1 No], Hinges, Type B-21 100mm Long [2 Nos], Suitable Handle [1 No] to each shutter complete all as specified and directed.Note : The weight of Aluminium sectons shall not be less than 1.20Kg/Rm. 29 Supply and fixing 5.5 mm thick, tinted glass exceeding 0.5 Square metre in each pane to aluminium door/window with glazing clips, rubber gasket etc complete all as specified and as directed. 30 Supply and fixing figured glass 5.5mm thick, pin head type, in square exceeding 0.5 Square metre in each panefixed in aluminium frame as in windows/ventilators, complete all as specified and directed. 31 Supply and fixing stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed. 32 Supply andfixing aluminium anodized grill 5.5mm thick weight not less than 2.5kg per square (in the shape of expanded metal aluminium xpmjalli) opening size length of expansion (60mm) and width expansion 45mm fixed in aluminium anodized windowwith ‘F’ channel of handle section with screw, complete all as specified and directed. 33 Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs any thickness, including cover fillets complete all as specified and directed. 34 S&F,Metal suspended ceiling system OREO GI laid in plain 600X600X0.50 mm (tegular) edge tiles in global white colour to be laid on strong 24mm T-section flanges colour white having rotary stitching on the main runner with web height of 38mm. Note:(i) To comprise main runner spaced at 1200mm centres securely fixed to the structural soffit at 1200mm maximum centre.The first/last suspension system at the end of each main runner should not be greater than 450mm from the adjacent wall.Flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm centre to form 1200x600 mm mould.Cut cross tees longer than 600mm require independent support. 600X600mm module to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200mm cross tees.Perimeter trim to be wall angles of size 3000x19x19mm,secured to walls at 450mm maximum centres. (ii) Suspension system accessories consisting of HLC sleeve anchor fasterners of thread size 6.50 mmx25/5 with soffit cleat made of galvanised steel of size 27x37x25x1.60mm & level clip in dimensions of 85x30x0.80 mm with 4mm GI wire complete all as specified & directed.Note- Ceiling tiles and ceiling grid shall be of the same make. 35 Dismantling plain or corrugated mild steel sheeting any gauge, thickness, including Nanital or similar pattern roof coveringcomplete, all as specified and directed. 36 Supply and fixing of Pre-painted galvalume aluminuim zinc coating GI based corrugated steel sheet 0.50mm thick, conforming to IS-15961 of any colour having tensile strength of 550 MPa as in roof covering/cladding to wall, fixed with self tapping screws, complete, all as specified and as directed.Note- The sheets shall have (150 gm/sqm total on both sides) with super durable polyester quality paint of approved colour, suitable for exterior application conforming to IS-15965. 37 Supply and fixing ofPre-painted galvalume aluminuim zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 MPa as in roof covering/cladding to wall, fixed with self tapping screws, complete, all as specified and as directed.Note- The sheets shall have (150 gm/sqm total on both sides) with super durable polyester quality paint of approved colour, suitable for exterior application conforming to IS-15965. 38 Dismantling of wrought iron or mild steelwork of any description not otherwise specially providedcomplete all as specified and directed. 39 Supply andfixing mild steel, rolled sections as in main orcross beams, hip and jack rafters, purlin where connected to comman rafters and running rails and guides for sliding doors fixed with angle cleats or other connecting platesconforming to grade Fe-410(Gde 250), complete all as specified and directed. 40 Demolition of cement concrete of any description and in any position not otherwise specifically provided for including removal the rubbish/ demolished material outside defence land, complete all as specified and directed. 41 Material and labour for applying water proofing treatment to sunken slab comprising of the following specifications complete all as specified.(i)Cleaning of roof surface with mechanical means i.e. wire brush/air blower etc. andremove all loose /unsound material,dirt,dust etc, (ii) 15mm thick cement plaster on concrete surfaces in cement mortar (1:3) using and including water proofing compound @3% by weight of cementfinished even andsmooth without using extra cement,.(iii)Providing and laying water proofing treatment of sunken portion of WCs, bathroom etc by applying cement slurry @ 1.3 kg/sqm mixed with acrylic based polymer modified cementitous composit compound coating of make as approved in Technical Instruction 5/2003(iii)First layer of cement slurry @ 0.488 Kg/Sqmmixed with acrylic based polymer modifiedcementitious composite compound @ 0.253 Kg/Sqm of approved make and allowed layer to air cure for 04 hours.(iv)Second layer of cement slurry @ 0.244 Kg/Sqmmixed with acrylic based polymer modifiedcementitious composite compound @ 0.126 Kg/Sqmand allowed layer to air cure for 04 hours followed with water curing for 48 hrs .(v) 200 micron thick polythene film pasted with the hepl of adhesive shall be provided over treatment . 42 item No. 40.00(contd....)Note :-(i)The slope of slab shall be 1:20 towards the corner of outer walls and GI pipe of 40mm dia ( Medium grade ) be inserted at corner projecting out side 20 cm . (ii) Joints of WC/Trap/Soil waste shall be properly sealed with sealing compound(iii) P/S traps and Nahani/Floor traps with long arm shall be provided as per latest instruction .(iv) Testing of all trap & joint and sunken slab shall be as per IS-1742 before filling and tilling of sunken slabs, including smoke test. (v) The water proofing treatment shall be carried out by the manufacturer or his authorised applicators and contractor shall also provide 07 yearsGuranttee forwater proofing treatment carried out in the work. Testing of all traps and joint and sunken slab shall be done as per IS-1742 before filling and tiling work. 43 Material and labour for PCC 1:5:10 type E-2, using 40 mm graded crushed stone aggregate as in filling in sunken floor, rounded or chamfered on edges complete all as specified and directed . 44 Supply only integral water proofing compound complete all as specified.as directed . 45 Supply and fixing vitreous china wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern)including plastic water closet seat white closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinges device and brass chromium plated Jet spray with PVC pipe andcomplete accessories as in repair, complete all as specified and as directed. 46 Supplyand fixing (in repair) brass chromium plated jet sprayer suitable for water closet pedestal pattern including 90cm long Chromium plated flexible pipe fixed to angle valve 15mm bore, complete all as specified and directed . 47 Supply and fixing 75mm dia of outlet, PVC (SWR) floor trap plain with grating including jointing with solvent cement, complete all as specified.(Note- UPVCfittings shall be conforming to BS 4515 DIN 19531 and DIN 19534) 48 Material and labour for 25mm thick PCC 1:2:4 type B-0 using 12.5mm graded stone aggregate as levelling course, finished even and fair to receive floor finishes, complete all as specified and directed. Note- This item shall not be executed in the location, where dismantling of tiles work have been done. 49 Supply and fixing 40 mm dia GI pipe , medium grade as in spout for sunken floor, fixed as in wall inside end fixed with wire netting and external bevelled edge at 45 degree, complete allas specified and directed. 50 Demolition ofcement concrete in ground floor and pavings not exceeding 15cm thickness (below or above ground level) and removal the rubbish/ demolished material outside defence land, complete all as specified and directed. 51 Material and labour providing 75 mm thick cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregates as in plinth protection laid in alternatebays (not exc 2 Sqm each )and finished even and smooth without using extra cement and providing jointsthroughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight including form work complete all as specified and as directed. 52 Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. 53 Material and labour for screed bed or bedding layer of mortar, 15 mm thick for laying floor finishes in cement mortar 1:4 complete all as specified and as directed. 54 Material andlabour for premium quality, joint free, non skid, coloured ceramic 7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm tiles, as in floor, set and jointed in neat cement slurry @ 3.00 kg/square metre and pointed in white or coloured cement to match the surface over cement screed bed , complete all as specified and as directed. 55 Material and labour for glazed ceramic coloured/printed tiles 450mm x 350mm x 6 to 7mm thick on vertical surfaces as in skirting, dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, laid over and including 10mm thick bedding layer in cement mortar (1:3), complete all as specified and directed. 56 Material andlabour for 2nd class hard wood plain, solid straight chowkats and frames, wrought framed rebated on the solid, rounded or chamfered put together with glue pinned at joints complete, all as specified and directed. 57 Material and labour for 18/19mm thick pre laminated particle board, exterior grade, pre-laminated one side with decorative choice lamination and other side balancing white lamination with 1st class hard wood 5mm thick teak wood edging all around, fixed with screws to timber framework and leaping treated with french polish suitable for cup board shutters, palmet box, etc.complete all as specified and as directed. 58 Supply and fixing, extruded aluminium alloy handles with plates, fabricated type, anodised 75mm size, ISI marked, complete all as specified and directed . 59 Supply and fixing in repairHarrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc. 25 mm dia with brackets etc complete all as specified and directed . 60 Dismantling water tanks of capacity exc. 250 ltr and not exc. 500 ltrs and removing from site complete all as specified and as directed. 61 Supply and fixing water storage tank 500 ltr capacity HDPE triple layer, confirming to ISstandard, fixed andhoisted in position on staging or roof complete with locking arrangement including provn of over flow pipe, air lock pipe, brass valve high pressure with polythene float and flynut , ISI marked, screwed and suitable for iron pipe 20 mm bore, complete all as specified and directed 62 Taking up or down steel tubing and connections for 15mm dia including cleaning for refixing or removal to store complete all as specified and directed . 63 Supply and fixing of 15mm dia tubes, medium grade, galvanized, ISI Marked, with all fittings such as sockets, bends, elbows, tees etc, fixed to walls and ceiling or laid in floors, including cutting existing steel tubing and screwing, if required for alterations and additions, complete all as specified and directed. 64 Refixingsteel water tubing of 15 mm bore in new or old position withall new fittings as required, laids in floor , wall and on ceiling, complete all as specifiedand directed. 65 Taking up or down steel tubing and connections for 20mm dia including cleaning for refixing or removal to store complete all as specified and directed . 66 Supply and fixing of 20mm dia tubes, medium grade, galvanized, ISI Marked, with all fittings such as sockets, bends, elbows, tees etc, fixed to walls and ceiling or laid in floors, including cutting existing steel tubing and screwing, if required for alterations and additions, complete all as specified and directed. 67 Refixingsteel water tubing of 20 mm bore in new or old position withall new fittings as required, laids in floor , wall and on ceiling, complete all as specifiedand directed. 68 Taking down shutters of any description but not exceeding 1.00 Sq.m eachfrom chowkhat and removing from site complete all as specified. 69 Taking down shutters of any description exceeding 1.00 Sq.m but not exceeding 2.00 Sq.m each, from chowkhat and removing from site complete all as specified. 70 Material and Labour for plain cement concrete 1:3:6 type C-1 (using 20 mm graded mechanically crushed stone aggregates) as in fixing of hold fasts, copings, bed plates,kerbs or mud stops,lintels upto 1.50m span, plinth courses , seismic and other bands and the like, finished the surface fair andeven, including necessary form work complete all as specified and directed. Note- If reinforced concrete, reinforcement shall be measured and paid for separately. 71 Supplyand fixing factory made flush shutters 30 mm thick, solid core construction, with block board core and plywood face panels, commercial type on both sides, ISI marked complete all as specified. 72 Supply and fixing 35 mm thick, 2nd class hard wood, partly or fully glazed and skelton shutter open rebatedand prepared to receive glass ,gauge etcdivided into squares with plain, chamfered or rounded, mitred beads, rebated sash bars any numbers for securing glass, etc or partly with panels of 9mm BWP commercial ply etc with size of members of shutters as specified in SSR Part-I, section 8 clause 8.24(a) or to match with existing shutters etc complete all as specified and as directed. 73 Suppling and fixing solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet, reinforced with M.S. square tube and fixing in opening as per specification complete all as specified and as directed. 74 Suppling and fixing Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M. S. tubes for top & bottom rails. M. S. frame shall be covered with heat moulded plain colour PVC `C` channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side & as gap insert for top rail & bottom rail. Panelling of plain colour PVC sheet to be fitted in the M. S. frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement,fixing in the frame as per specification complete all as specified and as directed. 75 Taking down existing earthing continuity conductor, aluminium strip 25X3.15 mm ,and removing to store for keeping safe custody for refixing and makinggood to surface complete all as specified anddirected . 76 Taking down existingAir termination single pointed aluminuim Rod 12 mm dia 300 mm longremoving to store for keeping safe custody for refixing and refixing the same after completion of civil work complete all as specified anddirected . 77 Refixing of earthing continuity conductor aluminium strip 25 X 3.15 mm with saddles and screw, etc.drawn through conduit in trenches / under floor /on wall or on roof including insulator complete all as specified anddirected . 78 Supply andfixing mild steel butt hinge of 100mm length, cold rolled, medium weight, ISI marked complete all as specified and directed. 79 Supply and fixing mild steel, semi-barrel tower bolt 200 mm , open cover, with sheet pressed barrel, stove enamelled black with bright bolt complete all as specified and as directed. 80 Material and labour for preparing new or previously untreated wood and wood based surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified anddirected . 81 Material and labour for preparation of old surface of wood and wood based materials over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified anddirected . . 82 Material and labour for preparation of old steel surface of any description not otherwise described, over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed by the Engineer-in-Charge. 83 Dismantling of cast iron or reinforced concrete drain pipes of any size, jointed in cement mortar and taking out of trenches or from any position, complete all as specified and as directed. 84 Supply and fixing in repair, cast iron soil, waste and vent spun pipes 75 mm bore, ISI marked, in any length, with or without ears, with cement joints, laid in trenches or in floors complete, all as specified and directed. 85 Supply and fixing in repair, cast iron soil, waste and vent spun pipes 75 mm bore, ISI marked, in any length, with or without ears, with cement joints, fixed to wallcomplete, all as specified and directed. 86 Supply and fixing in repair, cast iron soil, waste and vent spun pipes 75 mm bore, ISI marked, in any length, with or without ears, with cement joints, laid in trenches or in floors complete, all as specified and directed. 87 Supply and fixing in repair, cast iron soil, waste and vent spun pipes 75 mm bore, ISI marked, in any length, with or without ears, with cement joints, fixed to wallcomplete, all as specified and directed. 88 Supply and fixing cast iron branch pieces, 100 mm dia, single (equal or unequal), ordinary or inverted(spigot or socket type) or with parallel branches complete, all as specified and directed. 89 Supply and fixing cast iron bends (any radius) 100 mm dia diminishing pieces or tapers complete, all as specified and directed. 90 Supply and fixing cast iron bends (any radius) 75mm dia diminishing pieces or tapers complete, all as specified and directed. 91 Supply and fixing cast iron branch pieces, 75 mm dia, single (equal or unequal), ordinary or inverted(spigot or socket type) or with parallel branches complete, all as specified and directed. 92 Supply and fixing vitreous china wash hand basin, white , flat back of size 550mmx400mmfixed on and including cast iron cantilever bracket, 32mm dia brass waste coupling chromium plated and 32 mm dia PVC waste pipe including fixing ofwaste fitting, etc. as in repair complete all as specified and as directed. 93 Supply and fixing in repair,15mm bore pillar tap, chromium plated, cast copper alloy with capstan head, screwed down, high pressure, with or without lettered ‘Hot’ or ‘Cold’ complete all as specified and directed. Make--PRIMA Cat No PPL-5309 or equivalent model in makes mentioned in Appendix B of tender document.Note- Contractor shall submit a guarantee certificate from manufacturer to Engineer-in-Charge before claiming payment. 94 Supply and fixing in repair, stop valves, 15 mm dia pipe, chromium plated, fancy type, ISI marked, screwed down, high pressure with capstain head, (concealed type) with sliding flange, screwed both ends for 15mm bore pipes or for unions complete all as specified and directed.Make- PRIMA Cat NoPLF-6210or equivalent model in makes mentioned in Appendix B of tender document.Note- Contractor shall submit a guarantee certificate from manufacturer to Engineer-in-Charge before claiming payment. 95 Supply and fixing in repair, bib tap, long body, screwed down, high pressure, cast copper alloy, fancy type, chromium plated, ISI marked, with capstan heads, screwed down suitable for 15mm bore pipe or union complete all as specified and directed.Make- PRIMA Cat No PLF-6202 or equivalent model in makes mentioned in Appendix B of tender document.Note- Contractor shall submit a guarantee certificate from manufacturer to Engineer-in-Charge before claiming payment. 96 Taking down bib tap, of any description removing to store for keeping safe custody for refixing and refixing the same complete all as specified anddirected . 97 Supply and fixing PVC connections 45cm long and 15mm dia with PTMT nuts and PVC washers on both ends, complete all as specified anddirected . 98 Excavating in trenches, not exceeding 1.50 metre wide and not exceeding 1.50m in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. not exceeding 10 sq.m on plan and not exceeding 1.50m in depth and getting out in hard/dense soil complete, all as specified and as directed. 99 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in soil of any description, complete all as specified and as directed. 100 Removing excavated soil to a distance not exceeding 50 metre and deposited where directed at a level not exceeding 1.5m above the starting point, complete all as specified and as directed. 101 Demolition of SGSW drain pipe of any bore jointed in cement mortar including PCC bedding/hunching, and taking out of trenches with fittings complete all as specified and as directed. 102 Material and labour for concrete bed to drain pipes of 110mm dia including packing under and hanging against the sides of pipes after they are laid and tested in cement concrete 1:4:8 type-D2 using 40mm graded mechanically crushed stone aggregate , complete all as specifiedand directed . 103 Supply andfixing in repair, for 2mm thick fibre glass reinforced translucent corrugated sheeting with two corrugation side lap fixed with L type or J type or cranked hook bolt in roof, wall etc. complete all as specified and as directed 104 Supply and fixing in repair 10 ltr PVC valveless syphonic action type flushing cistern with brackets, flush pipe etc complete including inlet ball valve float and handle including brackets, of approved make including all connections & flush pipes for WC complete all as specified and as directed. 105 Taking down copper/ aluminium point wiring(light, fan, socket or power) complete, including fittings and fixtures such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc removing materials to store for keeping in safe custody or for taking credit (fittings such as switches, sockets, ceiling rose, pendent holders, light fittings etc. are to be measured separately) and making good distrubed surfaces of wall, floors, etc. complete all as specified and directed. 106 Material and labour for Point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable flame retardant low smoke and low halogen FRLSH, 1100 volt grade for phase (red) and neutral (black), with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, PVC conduit not less than 20 mm dia with accessories, concealed on wall/ceilingand incuding provision of 1.50 Sqmm single core PVC insulated , unsheathed cable flame retardant low smoke and low halogen FRLSH, 1100 volt grade with multi stranded copper conductorgreen colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes made out of not less1.2 mm thick mild steel sheet metal conforming to IS with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer bothinternally and externally including provision of new 3 mm thick plastic laminated sheet top cover extended up to 25 mm over sunken box for housing the switches , socket outlets, fan regulators etc. with brass screws and brass washersand making goodthe disturbed surfaces as per existing for one ligh point controlled by one switch one way switch 6 Amp. Note :- Switch, socket and fan regulators to be measured and paid for separately . PVC Conduit confirming to IS 9537 part I & III. Note:- (All chases will be cut by chase cutter only). 107 Description all as per Srl item No.105 here in before but one ceiling fan/ exhaust fan point controlled by one way switch 5 Amp complete all as specified and as directed.. 108 Description all as per Srl item No.105 here in before but one bell point controlled by one bell push button complete all as specified and as directed.. 109 Description all as per Srl item No.105 here in before but one switch socket outlet 3 pin, 5 Amp on same board complete all as specified and as directed. 110 Description all as per Srl item No.105 here in before but one switch socket outlet 3 pin, 5 Amp on the independent board complete all as specified and as directed. 111 Description all as per Srl item No.105 here in before but one light point controlled by two way switch 5 Amp complete all as specified and as directed. 112 Description all as per Srl item No.105 here in before but 2.5 sqmm single core multi stranded copper conductor PVC insulated unsheathed(FRLSH) cable 1100 voltsincuding 2.5 sqmm stranded copper conductor (FRLSH) PVC insulated green in colour as continous earth conductor connected to common earth and earth dolly with all accessories for one 5 pin 16 Amp socket (Power point) on independent board complete all as specified and directed. 113 Description all as per Srl item No.105 here in before but 4.0 sqmm single core multi stranded copper conductor PVC insulated unsheathed(FRLSH) cable 1100 voltsincuding 4.0 sqmm stranded copper conductor (FRLSH) PVC insulated green in colour as continous earth conductor connected to common earth and earth dolly with all accessories for one 5 pin 16 Amp socket (Power point) on independent board complete all as specified and directed. 114 Supply and fixing switch piano 6 Amps, flush type, single pole, one way,230 volt , AC supply,ISI Marked, complete all as specified and directed. 115 Supply and fixing switch piano 16 Amps, flush type, single pole, one way,230 volt , AC supply,ISI Marked, complete all as specified and directed. 116 Supply and fixing switch piano 6 Amps, flush type, single pole, one way,230 volt , AC supply,ISI Marked, complete all as specified and directed. 117 Supply and fixing switch piano 16 Amps, flush type, single pole, one way,230 volt , AC supply,ISI Marked, complete all as specified and directed. 118 Supply and fixingswitch piano, bell push, 6 Amps, flush type, 230V, 50 Hz supply, complete all as specified and directed. 119 Supply and fixing switch piano 6 Amps, flush type, single pole, two way,230 volt , AC supply,ISI Marked, complete all as specified and directed. 120 Supply and fixing PVC power unit modular box (DBOXx) with MCB protected socket with plug top of 25 Amp complete all as specified and directed. 121 Supply and fixingfan regulator electronic step type(Socket type), 120 watt, 230 Volts, 50 Hz, AC supply suitable for ceiling fan any type/make/sweep complete all as specified. 122 Supply and fixing ceiling rose surface bakelite 65x50mm, type 2/3 terminal, isolated body complete all as specified and directed. 123 Supply and fixing for Bell, electric,Ding Dong type, AC, 230 volts, single pole complete all as specified and directed. 124 Supply and fixing lamp holder, PVC/polycarbonate angular type with back plate, complete all as specified and as directed. 125 Supply and fixing in replacement,LED lamp, 5 watt,threaded/pin end, warm/cool lamp type suitable for fixing onbatten/angular holders completeall as specified and directed. 126 Supply and fixingin replacement, LED lamp, 12 watt,threaded/pin end, warm/cool lamp type suitable for fixing onbatten/angular holders completeall as specified and directed. 127 Taking down carefully old unserviceable MCBs DBs any type including MCB SP/SPNand removing to store for keeping safe custody for taking credit and makinggood to surface completeall as specified and directed. 128 Supply and fixing sheet metal enclosures for distribution boardTPN, 4 ways, double door, 415 volts, with and including 200 amps rated bus bar, vertical type, with MCCB as incomer andMCBs as out going, conforms to IS:8623.III, IP:43 protection and making all type of connections with suitable size of gland for incomer LT cable complete , concealed on the wall surface, making good the disturbed portion withadjoining surfaces to match with existing finish complete all as specified and as directed. 129 Supply and fixing factory made sheet metal MCB distribution board, 12 way with 200 Amps rated bus bar, single pole and neutral withdouble door IP-42 fixed on wall duly grouted in wall or on wooden board in and including copper lugs/thimbles duly crimped for connection, including making smooth the disturbed surfaces complete all as specified and as directed 130 Supply and fixing in replacement, MCCB 125A, 4 pole, 415 volts withbreaking capacity 16 kA and conforms to IEC 60947-2, complete all as specified & directed. 131 Supply and fixingin replacement, MCB,Single Pole and neutral, AC supply, 240 volts, 40-63 Amps,C series,10 kA rupturing capacityand making connections complete all as specified and as directed. 132 Supply and fixing in replacement, MCB,Single Pole, AC supply, 240 volts,06 to 32 Amps,C series,10 kA rupturing capacityand making connections complete all as specified and as directed. 133 Supply and fixing in replacement LED tube light batten fitting 20W (single side connection) including LED rod including all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable with suitable size complete all as specified and directed. 134 Supply and fixing in replcementLED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. 135 Supply and fixing in replacementLED surface mounted bulk head luminaries 10 watt with min 800 lumen, industrial model, IP 65, PVC housing, surge protection including driver & LED lamp, etc. complete with all accessories, connecting with copper conductor flexible cablefrom ceiling rose to connector of the light , complete all as specified and as directed. 136 Supply and fixing in replacement LED light fitting 25 W outdoor type for new generation energy saving and environmental friendally long life LED building security light made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having bottom opening seperate driver compartment with IP66 protection and impact resistance of IK08 complete all specified and directed.Note : The quoted rateinclude the provn of PVC flexible pipewhere connection wire providedfor light fittings, ceiling fan/ exhaust fan, etc. 137 Disconnecting and taking downceiling fans with blades, exhast fans, metallic body of any make and model andfrom its locations and kept in safe custody and refixing the same in the same location or in other location after completion of complete wiring and civil works including spray painting the steel surface with synthetic enamel paint by spray gun machine complete all as specified and directed.Note : (i) Flexible PVC insulated multistranded copper conductor single core two runs from ceiling rose to fan is inclusive in the quoted rate. 138 Disconnecting of exhast fans (air circulators) PVC body of any make and model and taking down from its locations and kept in safe custody and refixing the same in the same location or in other location, after completion of complete wiring and civil work including cleaning the same before fixing complete all as specified and directed. 139 Disconnecting and taking down of serviceable geysers of any description, capacity and make with its accessories from its locations and kept in safe custody and refixing the same in the same location or in other location, after completion of complete wiring and civil work including cleaning the same before fixing complete all as specified and directed. 140 Supply and fixing in replacement of exhaust fan metallic body 300mm sweep, AC, 230V, single phase, 50 Hz complete all as specified and directed.Make-Standard, model-FSVRASTGRY12 or equivalent make/model mentioned in Appendix B of CA complete all as specified and directed. 141 Supply and fix in replacement of air circulators fan (exhaust fan) PVC body for fresh air having 200mm sweep AC, 230V, single phase, 50 Hz, complete all as specified and directed. Make-Standard, model-FSVRFDXOWH08 or equivalent make/model mentioned in Appendix B of CA complete all as specified and directed. 142 Material and labour for GI bracket, medium grade, 40mm dia, 1.20 m length bent to required length, fixed to wall with two clamps made of 20 x 3 mm mild steel flat minimum 15cm long, 4 nos 8mm dia bolts with nuts with two coats of synthetic enamel paint over one coat of red oxide paint complete all as specified and directed. 143 Taking down carefully unserviceable sub main wiring of any size and type, removing material from site for taking credit and making good the disturbed surfaces of walls, ceilings etc including existing PVC/Steel conduit/ casing caping etc and removing materials from sites and making good distrubed surface of walls and roofs complete all as specified and as directed. 144 Material and labour for sub-main wiringwithsingle core PVC insulated sheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 6.0 sqmm (Nominal area) drawn through in and including PVC concealed conduit of required size not less than 25mm dia with all fittings and accessories alongwith one single core green colour PVC insulated sheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 4.0 sqmm as earth lead and connected to earth dolly and making good to disturbed surfaces etc, all as specified and directed. Note :-(i) Cutting/ Chasing of wall/ stair case etc. deemed to be included in the quoted rates of this item. (ii) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB.(iii) Three runs of cable and one run of PVC conduit shall be measured and paid as one unit length. 145 Disconnecting of old earthing and replacement with galvanised steel earth electrode plate of size 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50m below normal ground level, connected to galvanised iron earth lead 4mm wire upto test point with suitable GI nuts/bolts and brazed properly up to main board including earth pit in cement concrete 1:2:4 type B-1,precast RCC cover in 1:2:4 reinforced with expanded metal, with suitable handle, excavation and earth work in any type of soil and including medium grade GI watering pipe 20mm bore with funnel wire mesh and light grade GI wire protection pipe 15mm bore up to main board complete as shown in electrical plate No. 3 of MES schedule Part-I 2009, connected to earthing testing point including taking out existing unserviceable earthing complete all as specified and testing on completion complete all as specified and directed.Note - The units rate includes the cost of excavation & earth work in any type of soil, charcoal & salt in alternate layers, 20mm GI pipe (medium grade) for watering 15mm GI pipe for protection of wire (light grade) funnel wire mesh PCC chamber in PCC 1:3:6 type C-1 cast iron frame and 40mm thick RCC cover for pit etc & no extra payment will be made. 146 Amount of credit of Rs. 45622.00for retrived old material as mentioned in Schedule A section-II of tender document in pdf form, will be deducted offline while acceptence of tender.
Contract Date : 10 Feb, 2026   |   Contract Value : 21.48 Lakhs
BRR : 7529994 Tender For BALANCE WORK AT CANCER CARE HOSPITAL=3 Civil and Finishes Dismenteling / removing cement tiles, or marble or polishedshahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. complete 4 Civil and Finishes Dismantling the R.C.C. Work 1:2:4 and sorting out the materials such as steel etc. as directed and stacking them within the specified lead as directed etc. complete. 5 Civil and Finishes Dismenteling / removing of structural steel including ridge, hips, valleys, jackarch, battens, arches, purlins, trusses, GI Sheet, Asbestos cemnt sheet, gutters, buillt up sections, etc. and stacking the material at sutaible place at site or as directed by Engineer Incharge. 6 Civil and Finishes Removingdoorsandwindowswithframesandstackingthematerialsasdirectedwithall leads, lifts etc. complete. 7 Civil and Finishes Providing internal cement plaster 12mm thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. directed by Engineer Incharge. 8 Civil and Finishes Providing sand faced plaster externally incement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using water proofing compound at 1Kilogram per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8mm thick incement mortar 1:4 finishing the surface by taking out grainsandcuringforfourteendays scaffolding etc.complete. directed by Engineer Incharge. 9 Civil and Finishes Providing and laying Vitrified Floor Tiles in different sizes and of approved make, with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with epoxy grouts of 3mm width and with white cement & matching pigments etc. complete at specified locations as directed by Engineer in charge and complete.(Payment for grouting of joints to be made separately)Size of Tile 600mm x 600mm. 10 Civil and Finishes Providing and laying Vitrified tiles in different sizes and of approved make, with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, as approved by Engineer- in- charge, in dado, skirting, riser of steps, over 12mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600mm x 600mm./ 600mm x 300mm 11 Civil and Finishes Providing and applying gypsum plaster (withGypsummaterial )with finishing with gypsum material in10to13millimeter thickness to previously plastered surface/oron newly brick surface(Excludingroughcastplaster)in all position including preparing and Finishing the surface scaffolding etc.complete.directed by Engineer Incharge. 12 Civil and Finishes Providing and applying 2 coats of Washable, Anti-bacterial, Anti-fungal premium interior water based washable emulsion conforming to IS 15489 standard with washable & cleanable ability more than 4000 mechanical cyces; with VOC below 3% by mass; along with anti-fungul resistance conformance to ASTM D3273; and anti-bacterial resistance conformance to JIS Z 2801:2010 and coverage of 120-140 sq ft/ltr applied over one coat of Interior Sealer A700 or equivalent as per recommended application procedure Rate to be inclusive of 1 Coat of Primer + 2 Coats of Putty + 1 Coat of Primer. Approved Make Dulux Professional Solitaire or equivalent from Asian Paints, BergerStainResist or equivalent from Asian Paints, BergerSupply and Application cost of Paint to be Rs 255 per Sqm including taxes and delivered at site. 13 Civil and Finishes Painting and applying Exterior grade Texture Paint in desired Texture pattern and shade / colour of paint to the exterior walls / ceiling / RCC surfaces / any other location as desired by the EIC after preparation of the wall / RCC surfaces to the external surfaces of the building, filling in cracks with approved putty, with necessary one coat of primer as per the manufacturer specification, one / two coats of texture and min two coats of exterior grade paint including scaffolding, preparing the surface, curing, primer coat etc complete. Final Coat Paint should be done before Handing Over 14 Civil and Finishes Providing and laying Autoclaved Aerated Cement blocks masonry with 100mm / 150mm / 200mm / 230mm / 300mm thick AAC blocks up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineering-Charge. (The payment of RCC band and reinforcement shall be made for separately) 15 Civil and Finishes Providing selected hard murum filling including laying in layers of 15 to 20cm with watering and compacting etc. complete. directed by Engineer Incharge. 16 Civil and Finishes Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, includingremoving the excavatedmaterial up to a distance of 50m. beyond the building area andstacking and spreading as directed, dewatering, preparing the bed for the foundation and necessarybackfilling,ramming,watering includings horing and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Meansdirected by Engineer Incharge. 17 Civil and Finishes ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-25oftrap/granite/quartzite/gneissmetalforR.C.C.workinfoundationslike raft,strip foundations,grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water,Steel centering,formwork,coverblocks,laying/pumping,compactionandcuring roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 18 Civil and Finishes Providing and fixing in position TMT-FE-500 bar reinforcement of various diametersfor R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings andschedules. includingcutting, bending,hookingthebars, binding with wires or tack welding and supporting as required complete. directed by Engineer Incharge. 19 Civil and Finishes Providing and constructing O/H storage of 450mm depth and size as per drawings, with top, sides, bottom, back, all vertical and horizontal intermediates, shutters, edges all as per detail drgs. All external surfaces to be finished in approved laminate, with balancing laminate on the interior surface. All exposed edges for intermediates to be in PVC edge binding / post formed. Rate to include hardware such as approved locks, auto closing hinges for shutters, approved handles, door stop, tower bolt, etc. complete. (Carcase made in exterior grade MDF)directed by Engineer Incharge. 20 Civil and Finishes Stainless Steel Rack and TrayProviding and fixing storage in 20 gauge Stainless Steel (SS) grade-304 slotted angle of 35mmx35mm finished with approved shade powder coating with 450mm wideinclusive of necessary powder coated nut-bolt fittings, edge guard bush for slotted angles etc complete as directed. The standard size of the slotted angle to be 900x1800mm with 4 Nos. of vertical shelves (approximate size. Please check at site)Approved Make: Steeledge / Kompress / Godrej / Space Planneror directed by Engineer Incharge. (Elevation area to be considered for measurment purpose) 21 Civil and Finishes Providing and fixing factory finished Factory Finished DB Shutters (300mm - 450mm deep) in 19mm thick Exterior grade MDF finished in approved shade laminate on exposed surface and balancing laminate on the interior surface with PVC edge banding from Rehau make or matching colour polish. Rate to be inclusive of back, sides, top, bottom in fire rated ply and finished approved laminate as directed and framework in seasoned teak wood of section 50mm x 100mm, finished in colour polish matching the colour of the laminate. Rate to be inclusive of approved handle, tower bolts, Locks, magnetic ball-catch etc complete as directed. Each shutter shall have CNC Cut MDF louvers (Paint finished) at the bottom and one at the top. Rate to be inclusive for above the storage upto the false ceiling ply boxing finished as per shutter. MODE OF MEASUREMENT TO BE SURFACE AREA OF OPENABLE SHUTTERS ONLY. a directed by Engineer Incharge.. 22 Civil and Finishes Providing and fixing Trap door in the false ceiling for HVAC in 19mm thick marine plywood cladded with 4mm thick exterior grade MDF and finished in three coats of approved Acrylic Emulsion paint, inclusive of 19mm thick marine ply framework finished in matching paint. All the edges to be ofteak wood lipping and finished in approved melamine. The rate to be inclusive of necessary 19mm thickplywood support from ceiling etc. complete.directed by Engineer Incharge. 23 Civil and Finishes MGPS Valve Box Closing-Providing and fixing Screen, madeup in 100mm x 50mm x 1.7mm thick Aluminium Box section and Ply , trench cover and supports. directed by Engineer Incharge. 24 Civil and Finishes Providing and fixing of fabric wrapped 12mm thick Soft board panels of approved make on the existing ply backing of required sizes as per architectural drawings including making necessary cut out / opening in existing gypsum board partitions for fixing the same. The panels to be finished with fabric (Basic rate to be Rs 350 per Rmt including taxes) of approved shade, colour and make. 2mm thick foam of approved make to be infill between board and fabric as per architectural drgs. Fabric shall be stretched uniformly along the direction of weave and shall be wrinkle free and all edges to be finished in PVC wall gripper of WALL TRACK or equivalent make etc complete and as directed by Engineer in charge. 25 Civil and Finishes Indor Plants with Decorative PotsSUPPLY ,PLANTING AND MAINTAINACE OF PLANT SPECIMENTREESSupply of healthy sapling, vigorous specimen, well shaped, healthy fronds and well established and Planting of plant specimen including, loading, unloading of plant from project area to desired locations,support stacking guying, basin preparation for irrigation,watering and removal of unserviceable material’s as per direction of Engineer-in-charge Including lifting, loading, unloading of plant to Project site and maintaince of plants in healthy conditions till plantation.(excluding cost of plant & water)etc. Maintaining till handover by cleaning, watering, weeding, pruning ,stirring of soil, staking, replacing casualties etc. Complete.as per directive given by engineer incharge.Note: 1. Plantation included SIX months casuality replacement (Free of cost). 2. Water source shall be provide by client.TREE SPECIMEN Height-500-700Canopy-200-500Stem dia- 20-30 mm DBHClear Stem ht-600 26 Civil and Finishes Kerb Stone painting works -Painting with synthetic enamel paint, having VOC (Volatile Organic Compound) content less than 150 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.as per directive given by engineer incharge. 27 Civil and Finishes Providing and applying two coats of lead/zinc base oil paint/ bituminious paint of approved colourtonewstructuralsteelworkandironworkinbuildingsincludingscaffoldingif necessary, cleaning and preparing the surface etc.complete. (Includingprimer coat). 28 Civil and Finishes Providing and laying factory made coloured chamfered edge Cement Concrete paver blocks of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of fine sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with river sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand in footpath, parks, lawns, drive ways or light traffic parking etc. complete as per manufacturers specifications & direction of Engineering-Charge. 60mm thick C.C. paver block of M-35 grade with approved colour, design & pattern. or directed by Engineer Incharge.80 mm thick C.C. paver block of M-30 grade with approvedcolor design and pattern. 29 Civil and Finishes ProvidingandlayingCastinsitu/ReadyMixcementconcreteinM-10oftrap/granite/ quartzite/gneissmetalforfoundationandbeddingincludingbailingoutwater,Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided,finishingifrequiredandcuringcomplete,withfullyautomaticmicroprocessor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete.With fine aggregate (Crushed sand VSI Grade) or directed by Engineer Incharge. 30 Civil and Finishes Providing second class Burnt Brick masonry withconventional / I.S. type bricks in cement mortar 1:4 including scaffolding, racking out joints and watering etc. in pillar of rectangular shapes as shown in the drawings or as directed complete. 31 Civil and Finishes Providinga nd fixing of Kota stone slab flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) 25mm thick 32 Civil and Finishes Construction of Granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge.With material conforming to Grade-II (size range 53mm to 0.075mm) having CBR Value-25 33 Civil and Finishes Cleaning or washing of existing bituminious road surface including cleanig of dust, watering, Cleaining of road surface by vacume pump, etc. completed or as directed by Engineer Incharge 34 Civil and Finishes Providing and applying tack coat using hot straight run bitumen of grade VG - 10, including heating the bitumen, spraying the bitumen with mechanically operated spray unit fitted on bitumen boiler, cleaning and preparing the existing road surface as per specifications.On bituminous surface @ 0.75 Kg / sqm 35 Civil and Finishes Providing and laying of Type - B premix seal coat with HMP of appropratecrushed stone chipping 6.70 mm size and penetration bitumen of specified grade @ 0.68 Kg / Sqm. , preparing existing road surface including mixing in suitable Batch Mixplant and rolling bystatic roller having weight 8 to 10 MT. etc. complete. (VG-30 bulk bitumen rates are considered to arrive at rates) 36 Civil and Finishes Providing and layying of 25mm compacted thickness with bitumen of grade VG- 30 @ 5% (percentage by weight of total mix) and lime filler @ 2% (percentage by weight of Aggregate) prepared in Batch Type Hot Mix Plant of 100-120 TPH capacity. 37 Civil and Finishes Road marking strips-Providing and applying 2.5mm thick road marking strips (retroreflective) of specified shade / colour using hot thermoplastic material by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour ,T&P, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc. complete as per direction of Engineer-in-charge and accordance with applicable specifications.as per directive given by engineer incharge. 38 Civil and Finishes Repair to pot holesor patch repair by removal of failed material, trimming the sides to vertical and levelling the bottom, cleaning the same with compressed air or any appropriate method filled with 75mm B.M, applying bitumen tack coat at the bottom and vertical sides as per as per MORTH specification clause 3004.1 and 3004.2 39 Civil and Finishes Providing and fabricating structural steel work in rolled sections like joists, channels, angles, teesetc.asperdetaileddesignanddrawingsorasdirectedincludingcutting,fabricating, hoisting,erecting,fixinginpositionmakingriveted/bolted/weldedconnectionswithout connecting plates, braces etc. andincluding one coat of anticorrosive paint andover ittwo coats of oil painting of approved quality and shade etc. complete. 40 Civil and Finishes Providingandfixingpolycarbonate roofing sheetof6 mmthickfor roofing as per required colour including fastening and with accessories like screws and bolts as per drawing etc. complete or directed by Engineer Incharge 41 Civil and Finishes Providing and fixing 18mm thick gang saw cut, mirror polished, premoulded and prepolished granite stone, machine cut for kitchen / pantry platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 42 Civil and Finishes Providing & fixing of Corner guard 90 degree with cap inside amouminium thickness not less than 2 mm standard specification & approved by Architect. Rate has to be inclusive of all required necessary hardware & fittings as required & instructed by architect. Rate shall be include with all material shifting, temporary stand & scaffolding where ever required as per instruction by architect & PMC (Required material test certificate along with supporting document) Rate shall be include with material movement & shifting for all the floors.Basic Rate to be Rs 700 per Rmt including taxes and delivered at site.. 43 Civil and Finishes Removinggrass,gazergrassanddisposingoffoutofbuildingand trenches cleaningmaking clean the ground by shovel and phavaras etc. complete. Or directed by Engineer Incharge 44 Civil and Finishes Providing and fixing marine plywood 710 Grade marked 12 mm thick of approved make to existing framework, backing or studding with screws for additional support on existing dry wall for installtion of TV etc. complete oras directed by Engineer-in-charge. 45 Civil and Finishes Providing and fixing Flag Hosting Pote and Stagging in Circular steps as per the directions of Engineer-in-Charge. The Flag Hosting Pipe shall be of Staleness Steel and Staging shall be of civil works, painted white etc complete 46 Civil and Finishes Gypsum Board False Ceiling-Providing and fixing false ceiling at all height including providingand fixing of frame work made of special sections, power pressedfrom M.S. sheets and galvanized with zinc coating of 120 gms/sqm(both side inclusive) as per IS : 277 and consisting of angle cleats ofsize 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm,at 1200 mm centre to centre, one flange fixed to the ceiling withdash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, otherflange of cleat fixed to the angle hangers of 25x10x0.50 mm ofrequired length with nuts & bolts of required size and other end ofangle hanger fixed with intermediate G.I. channels 45x15x0.9 mmrunning at the spacing of 1200 mm centre to centre, to which theceiling section 0.5 mm thick bottom wedge of 80 mm with taperedflanges of 26 mm each having lips of 10.5 mm, at 450 mm centre tocentre, shall be fixed in a direction perpendicular to G.I.intermediate channel with connecting clips made out of 2.64 mmdia x 230 mm long G.I. wire at every junction, including fixingperimeter channels 0.5 mm thick 27 mm high having flanges of 20mm and 30 mm long, the perimeter of ceiling fixed to wall/partitionwith the help of rawl plugs at 450 mm centre, with 25mm long drywall screws @ 230 mm interval, including fixing of gypsum boardto ceiling section and perimeter channel with the help of dry wallscrews of size 3.5 x 25 mm at 230 mm c/c, including jointing andfinishing to a flush finish of tapered and square edges of the boardwith recommended jointing compound , jointing tapes , finishingwith jointing compound in 3layers covering upto 150 mm on bothsides of joint and two coats of primer suitable for board, all as permanufacturers specification and also including the cost of makingcove a vertical brand and openings for light fittings, grills, diffusers,cutouts made with frame of perimeter channels suitably fixed, allcomplete as per drawings, specification and direction of theEngineer in Charge .Including the cost of painting with 2 coats ofprimer 2 coats of putty 2 coats of antimicobial paint at all heightupto satifaction of PM incharge .cove not be measured seperatelyonly plan area to be measured.12.5mm thick tapered edge gypsum plain board conforming toIS:2095- Part I 47 Civil and Finishes Tree relocation ofhealthy sapling, vigorous specimen, well shaped, properly branched and well established and Planting of shrubspecimen including, loading, unloading of shrub from project area to desired locations, support stacking guying, basin preparation for irrigation, watering and removal of unserviceable material’s as per direction of Engineer-in-charge Including lifting, loading, unloading of plant to Project site and maintaince of plants in healthy conditions till plantation.(excluding cost of plant & water)etc. Maintaining till handover by cleaning, watering, weeding, pruning ,stirring of soil, staking, replacing casualties etc. Complete.Note: 1. Plantation and Tree relocation of plants and shurbs etc. 2. Water source shall be provide by client.TALL HEIGHT SHRUB PLANTATIONHeight:1m-2mCanopy:450-600 48 Civil and Finishes Providing fixing and installation of water proofing course whereever required using as pre approved methodology by FOSROC, BASF or any other renound chemical waterproofing agency. (Any of the work required 10 years performance gurrantee bond must be signed on nonjudiciary stamp paper in the favour of CCCF ) 49 Civil and Finishes Providing and applying Core Cuttingactivity for new core of various sizes from 75 mm to 200 mm. 50 Civil and Finishes Fixing or laying of floor tiles or wall tiles work at required places as per directive given by Engineer Incharge 51 Civil and Finishes WATER METER SIDE- WASTE MATERIAL LEVELLING WORK: Providing and fixing enclosed type water meter (bulk type) conforming to IS : 2373 and tested by muncipal board complete with bolts,nuts rubber, insersions etc. ( the tail plases if required will be paid seperatly )as directed by engineer incharge.100 mm nominal bore 52 Electrical Works SIGNAGE WIRING EXTERNAL &INTERNAL ROOMWiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. directed by Engineer Incharge.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 53 Electrical Works EARTHING PIT REWORKProviding and fixing 25 mm X 5 mm G.I. strip on surface or inrecess for connections etc. as required accesorries. directed by Engineer Incharge. 54 Electrical Works DDC PANEL WIRING WITH SOCKET &BMS DDC wiring.Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. directed by Engineer Incharge. Wire 55 Electrical Works BURY OF HT CABLE (NEAR VCB ROOM)300 sqmm Aluminium Cable &external LT CableLaying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. directed by Engineer Incharge. Above 120 sq. mm and upto 400 sq. mm 56 Electrical Works Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.as per directive given by engineer incharge. Upto 35 sq. mm 57 Electrical Works WATER TANK SUPPLY - SUPPLY OF CABLES - XLPE INSULATED, FR-LSH PVC SHEATHED COPPER CONDUCTOR ARMOURED CABLES (IS:7098 Part-I)Supply of following sizes of 1.1kV grade XLPE insulated, Extruded FR-LSH PVC inner sheath Type ST-2, FR-LSHPVC outer sheath Type ST-2, stranded Copper conductor, Armoured cables as per IS:7098 Part-I.as per directive given by engineer incharge. 4C x 6 sq.mm.Cu. Ar. XLPE cable 58 Electrical Works LAYING OF CABLES- ON EXISTING TRAYS/ IN EXISTING DUCTS/ IN EXISTING CIVIL TRENCHES (IS:7098 Part-I)Laying, Fixing, Testing & Commissioning of following sizes of 1.1kV grade XLPE insulated, Extruded FR-LSH PVC inner sheath Type ST-2, FR-LSHPVC outer sheath Type ST-2, stranded Copper conductor, Armoured cables as per IS:7098 Part-I on existing cable trays/ in existing hume pipes/ PVC pipes/ GI pipes/ on surface of slabs, walls or masonary/ RCC trenches/ ducts including cables ties, GI saddles, clamps and necessary hard ware. directed by Engineer Incharge.4C x 6 sq.mm.Cu. Ar. XLPE cable 59 Electrical Works CABLE TERMINATION (IS:7098 Part-I)Cable end Termination of following sizes 1.1kV grade XLPE insulated, Extruded HR PVC inner sheath Type ST-2, FR-LSH PVC outer sheath Type ST-2, stranded Copper conductor, Armoured cables as per IS:7098 Part-I including cost of tinned copper, heavy duty crimpping lugs, double compression glands, insulation tape and all necessary material to complete the termination. directed by Engineer Incharge.4C x 6 sq.mm.Cu. Ar. XLPE cable 60 Electrical Works Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. directed by Engineer Incharge. Module (200mmX75mm) 61 Electrical Works MCB,BOXSupplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing an commissioning etc. as required. directed by Engineer Incharge.. Triple pole and neutral 62 Electrical Works Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. directed by Engineer Incharge. Upto 120 sq. mm 63 Electrical Works Supply and installationof LUGSFOR TERMINATION. as directed by engineer in charge. Copper Lugs 35 Sq.mm Plam Type 64 Electrical Works Supply and Installation of LUGSFOR TERMINATION. as directed by engineer in charge. Copper Lugs 70 Sq.mm Plam Type 65 Electrical Works Supply and Installation of LUGSFOR TERMINATION. as directed by engineer in charge.Copper Lugs 50 Sq.mm Plam Type 66 Electrical Works Supply and Installation of LUGSFOR TERMINATION. as directed by engineer in charge.Copper Lugs 95 Sq.mm Plam Type 67 Electrical Works Supply and Installation of LUGSFOR TERMINATION. as directed by engineer in charge.Copper Lugs 240 Sq.mm Plam Type 68 Electrical Works Supply, testing, installation and comissioning of Net Meter,ABT Meter, Combiner Box,Genration Meter and CTPT etc. as per drawings and designing. Directive by engineer in charge. directed by Engineer Incharge. 69 Electrical Works Supply, of copper cable approved make or as Dirtected by engineer in charge. Size ofcopper cable 1C X 50 Sq.mm 70 Electrical Works Supply, of copper cable approved make or as Dirtected by engineer in charge. Size ofcopper cable 1C X 70 Sq.mm 71 Electrical Works Supply, of copper cable approved make or as Dirtected by engineer in charge. Size ofcopper cable 1C X 240 Sq.mm 72 Electrical Works Supply, of copper cable approved make or as Dirtected by engineer in charge. Size ofcopper cable 2C X 50 Sq.mm 73 Electrical Works Conduits Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduitdirected by Engineer Incharge. Size 25 mm 74 Electrical WorksElectrical points including wires Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. directed by Engineer Incharge.2 X 4 sq. mm + 1 X 4 sq. mm earth wire 75 Electrical Works Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc directed by Engineer Incharge. 3 Module (100mmX75mm) 76 Electrical Works Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc directed by Engineer Incharge.6 Module (200mmX75mm) 77 Electrical Works Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc.directed by Engineer Incharge. 5 pin 16 amp socket outlet 78 Electrical Works Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc.directed by Engineer Incharge.5 pin 6 amp socket outlet 79 Electrical Works Fire Supression System for Hub Room and Server RoomTOTAL ROOM FLOODING SYSTEMSupply, Installation, Testing and Commissioning of 1x34 Itr completely CCOE approved high pressure seamless BIS 7285approved Cylinders having 34 ltr capacity, UL/FM/VDS approved FK5-1-12 clean agent gas with UL/FM/VDS listed valve assembly and electricsolenoid switch. The system also to be fitted with low pressure supervisoryswitch for monitoring cylinder pressure gauge with safety burst disc safetycap, elbow and other accessories, mounting bracket, container straps, NRV, Pressure operated control head which shall allow for pressure actuation ofgas mounted, manually operated actuator to actuate the gas floodingprocess with the help of a lever, flexible rubber hose with wire braldedenforcement to route the gas from the storage cylinder to the dischargepiping, to be connected to the discharge outlet of gas cylinder valve & to beterminated at the system piping or discharge manifold, Flexible actuationhose complete as required. Discharge nozzle, 180/360 degree. Designatedto provide proper flow rate & distribution FK5-1-12 gas to flood the hazardarea as per latest NFPA 2001 requirement. Piping ASTM grade A 106schedule 40 with fittings & supports and Gas Release Panel compatible to directed by Engineer Incharge.Fire Alarm System. (HUB ROOM- GF ) Complete Installation, Testing and Commissioning of above Items 80 Electrical Works Providing and fixing following rating and breaking capacityand pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. directed by Engineer Incharge.100Amp,30KA,FPMCCB 81 Electrical Works Providing and fixing Male connector schnider make81282 3P+N at required place 82 Electrical Works Providing and installation offlood light for terrace including 110 Watt or as directed by Engineer Incharge 83 Electrical Works Point wiring in for light/fan/bell in 20 mm metal conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire,flush type switch, earthing and required accessories as per specification no. WG-PW/SW 84 Electrical Works Providing and installation of alluminium cable 4C X 25 Sqmm forDX unit 85 Electrical Works Providing and fixing U/V Filters for Flow: 250LPH UV Dose: >300J/m2 UVT: 98% HSN Code: 84212190 86 Electrical Works Providing and fixing U/V Filters for Flow: 2000LPH UV Dose: >300J/m2 UVT: 98% HSN Code: 84212190 87 Electrical Works Supply and laying including termination of voice/data cabling in existing conduits including terminations:Cat 6A cabling 88 Plumbing Works DIALYSIS machine facilitiesProviding and fixing on walls/ ceiling/ floor 32mmdia. uPVC pipe with necessary fittings, remaking good the demolished portion etc.complete. Including removing existing pipeline if necessary and conveying and stacking the same in PWD chowky or asdirected by Engineer Incharge. etc. complete. 89 Plumbing WorksWATER TANK SUPPLY LINESupply, Installation, Testing and Commissioning of Piping NetworkUPVC Pipe 63mm OD-6kg/cm2 etc. completed or directed by Engineer Incharge. 90 Plumbing WorksWATER TANK SUPPLY LINESupply, Installation, Testing and Commissioning of Piping Network UPVC Pipe 50mm OD-6kg/cm2 etc. completed or directed by Engineer Incharge. 91 Plumbing WorksWATER TANK SUPPLY LINESupply, Installation, Testing and Commissioning of Piping NetworkUPVC Pipe 40mm OD-6kg/cm2etc. completed or directed by Engineer Incharge. 92 Plumbing WorksHAND RAIL SHOWER AND EYE WASH COCK(SECOND FLOOR)Providing and installation of eye wash as per drawings and designing as per engineer in charge 93 Plumbing WorksSupply and Installation of20 mm diameterElbow or as directed by Engineer Incharge 94 Plumbing WorksSupply and Installation of 32 mm Elbow or as directed by Engineer Incharge 95 Plumbing WorksSupply and Installation of 20 X 15mm Brasselbow or as directed by Engineer Incharge 96 Plumbing WorksSupply and installtion of 32X15mm Brass Elbow or as directed by Engineer Incharge 97 Plumbing WorksSupplya nd installation of 32 mm Socket or as directed by Engineer Incharge 98 Plumbing WorksSupply and Installation of 20 mm Socket or as directed by Enginner Incharge 99 Plumbing WorksSupply and installation of 20 mmsize tee or as directed by Engineer Incharge 100 Plumbing WorksSupply and installation of 32 mmsize tee or as directed by Engineer Incharge 101 Plumbing WorksSupply and installation of 20 mm size FTA or as directed by Engineer Incharge 102 Plumbing WorksSupply and Installation of 32 mm FTA or as directed by Engineer Incharge 103 Plumbing WorksSupply and installation of20 mm MTA or as directed by Engineer Incharge 104 Plumbing WorksSupply and installation of 32 mm MTA or as directed by Engineer Incharge 105 Plumbing WorksSupply, installtion, testing and commissioning of UV lamp of minimum capacity 2000LPH and minimum lamp wattage 15W 106 Plumbing WorksProvidingand fixingonwalls/ ceiling/ floor 50mmdia. CPVCpipewithnecessary fittings, remaking good the demolished portion etc. complete. 107 Plumbing WorksSOLID WASTE DISPOSALRemoving grass, gazer grass and disposing off out of building premises including making clean the ground by shovel and phavaras etc. complete.as directed by engineer incharge 108 Testing Works Providing testing installation and comissioning of Medical Gas Oxygen Cylenders as per required qty.as directed by engineer incharge1 D Type Empty Oxygen Cylinder (Capacity-46.7 Liter) 109 Testing Works Providing testing installation and comissioning of Medical Gas Oxygen Cylenders as per required qty.as directed by engineer inchargeD Type Empty N2O Cylinder (Capacity-46.7 Liter) 110 Testing Works Providing testing installation and comissioning of Medical Gas Oxygen Cylenders as per required qty.as directed by engineer inchargeD Type Empty N2O Cylinder (Capacity-46.7 Liter) 111 Testing Works Liquid Petrolium Gas (LPG) Third party test 112 Desing, Supply, Configure, Testing and Commissioning Electrical Low Voltage works as per the Attachment No 01 113 Providing staging and scaffolding as per the industrial standards upto 15 meters height including construction and disentailing etc complete. Decision of Engineer In Charge will be final and binding. 114 Provinding, laying and termination of 4 or 3 - 1/2 Core 300 MM Copper insulated cable as per the make and standard for connection of DG sets with Isolator Panels and other location as per the instructions of Engineer in-Charge. Etc completed.
Contract Date : 27 Jun, 2025   |   Contract Value : 5.66 Crore
BRR : 8169031 Special Repair To Washroom And Allied Works Of 1(T) Mess In Cti At Afs Jalahalli; 1 Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5 mtr in depth forfoundation, etc. orfor shafts, wells, cesspits,manholes, pier holes, etc. nexc 10 sq m on plan and getting out in hard / dense soil, complete all as specified and as directed. 2 Returning, filling incl spreading, levelling watering and well ramming in layers not exceeding 25cm in soft / loose soil for sewage pipe line manholes sides and cleaning the site, all as specified and directed. 3 Removing excavated materials (soils) to a distance not exceeding 50m and depositing where directed at a level not exceeding1.5 m above the starting point, all as specified and as directed. 4 Material & Labour for Pre-cast reinforced cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate) set in cement mortar 1:4 as in cover slab including all necessary form work, exposed surfaces of concrete shall be finished even and smooth without using extra cement, complete all as specified and as directed. 5 Material & Labour for RCC M-25 as in floor / roofSlab and roof projectionSlabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs, beams and columns and in shelves, completeall as specified and directed. 6 Material & Labour for Pre-cast PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) cement concrete block masonry with solid blocks exceeding 10cm in width and set in cement mortar 1:6 of any description, complete all as specified and as directed. 7 Material & Labour for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, lintels, Chajjas, cantilevers etc all as specified and directed. 8 Taking down chowkhat or frame (wooden / steel) exceeding 1.50 Sqm not exceeding4.0 Sqm each with shutter (with out taking off shutters from the frame), all as specified and as directed. 9 Taking down chowkhat or frame (wooden / steel) not exceeding1.5 Sqm each with shutter (with out taking off shutters from the frame) all as specified and as directed. 10 Material & Labour for second class hard wood, Plain, solid, straightchowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinnedat joints,suppliedandfixed complete all as specified and directed. 11 Material & Labour for Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65 x 125 mm(double rebat) comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/ SS dash fasteners of required dia and length complete all as specified and directed. 12 Material & Labour for Factory made PVC choawkats or frames of size 50x 47mm with wall thickness made out of extruded 5 mm rigid PVC foam sheet mitered at corner and jointed with 2 Nos of 150mm long brackets of 15mmMild Square tube the vertical door prattles to be reinforced with 19 x 19 mm Mild Steel square tube of 19 gauge EPDM rubber gasket door frame to be fixed to wall using Mild Steel screws of 65 / 100mm size as per manufacture’s specification,all as specified and directed. 13 Material & Labour for for 35 mm thick second class hard wood factory made panelled shutters with panel of 12 mm thick reneered commercial plywood kiln seasoned, chemically treated and with 15 x 6 mm teak wood edging all around the panels, complete all as specified and directed. 14 S&F Factory made solid panel PVC door shutter 28 to 30 mm thick (style) consisting of frame made out of Mild Steel tubes for top & bottom rails. Mild Steel frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail,Panelling of plain colour PVC sheet to be fitted in the Mild Steel frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame, all as specified and directed. 15 Material & Labour for 150mm long and 12mm dia stainless steel fasteners with round shape head, complete all as specified and directed. 16 Supply & Fix Mild Steel butt hinges medium weight cold rolled 100 mm size. complete all as specified and directed. 17 Supply & FixMild Steel butt hinges medium weight cold rolled 75mm size, complete all as specified and directed. 18 Supply & FixAluminium anoldised handle150 mm long, complete all as specified and directed. 19 Supply & FixAluminium anoldised handle125 mm long, complete all as specified and directed. 20 Supply & FixAluminium anoldised barrel tower bolt 125 mm long, complete all as specified and directed. 21 Supply and fixing 200 mm long aluminium anodized barrel tower bolt extruded section, complete all as specified and as directed. 22 S&F 300 mm (length of bolt) mild steel sliding door bolt (bolt type) above enameled black with bright bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate, complete all as specified and directed. 23 Supply & Fix Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm. & fixed with wooden beads / stainless steel wire stapels to fixing steel / wooden window&doors frame with nuts and bolts,all as specified and directed. 24 Supply & Fixin repairs Tubular Towel Rail 20mm dia, Brass Chromium Plated, D-type, 60 Cm long between Flanges with Bracket (one Pair) , complete all as specified and as directed. 25 Supply & Fixin repairs door stopper of aluminium alloy body and tongue anodized with hard drawn steel spring fixed in floor overall 140mm complete including taking down existing one,all as specified and as directed. 26 Supply & FixAluminium body door closer hydraulically regulated, designation No.3, universal type, suitable for door shutters of 851 to1000 mm in width and of weight between 61 to 80 kg and fixed including taking existing one complete as directed. 27 Supply & Fixin Steel windows with side hung shutters including projecting type hinges, frame with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and as directed.Note: (a) Specification of Steel windows / ventilators Box type using ERW ‘P’ Section comprising Double Frame for Gauged and Glazed Skeleton Shutters, having Outer Frame of Section 50 x 25mm and Inner Frame of Section 40 x 20mm, jointed internally with Mild Steel Flat Iron 40x3mm complete with Stainless Steel Tower Bolts, Hinges, Handles, Stops, Lugs, stays, etc,including steel painting and making good surface of wall by applying rendering to Jambs and cills, etc., complete all as specified and as directed.(b)For the purpose of Measurement and Payment Double Shutters with Frame shall be considered as ONE UNIT. (c)Unit Rate quoted shall deem to be included all the Stainless Steel Builders & Hardware as required / directed at Site. (d)Quoted Unit Rate shall also deem to be included Mild Steel Guard Bars of 10mm Square Bar, spacing at 10 Cm centre to centre on both Vertical & Horizontal directions.(e)Sheet Glass & wiremesh shall be Measured and Paid for separately under appropriate Item. 28 Supply & Fixmild steelhold fasts conforming to Fe 290grade -E--165 complete all as specified and directed. 29 Material & Labour for Steel reinforcement TMT bars 10mm dia and over cut to length and bent to shape required including cranking, bending spirally for hoping for columns, hooking end and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips incl removal of old reinforcement,all as specified and directed. 30 Material & Labour for Steel reinforcement TMT bars 6mm dia to 8mm dia cut to length and bent to shape required including cranking, bending spirally for hoping for columns, hooking end and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clipsincluding removal of old reinforcement all as specified and directed. 31 Dismantling floorhearth or wall tiling including cement mortar bedding but including screed bed and rendering plaster and removing debris, etc. to outside defence land, complete all as specified and as directed 32 M&L non skid coloured tiles 7 to 8mm thick (square/rectangular) area of each tiles exceeding .11 sqm but not exceeding. 0.18 Sqm in floor etc. set and jointed in neat cement sullery out pointed in white cement to match including screed or bedding layer of mortar 15 mm thick in cement mortar 1:4 for laying floor finishes complete all as specified and directed. 33 Material & Labour for coloured Glazed ceramic tiles in vertical surface450X350X7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick rendering or bedding layer in cement mortar 1:3 complete all as specified and directed. 34 Material and labour for 25mm thick Plain Cement Concrete 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) as wearing coat for layingfloor finishes, finished fair to receive tiles, complete all as specified and as directed. 35 Taking down cement plaster including raking out joints hacking for key, scrubbing down with water etc and removing debris, etc. to outside defence land, complete all as specified and as directed 36 Material & Labour for cement plaster rendering 10mm thick in cement mortar 1:6 on fair faces of brickwork or concrete surface of wall, finished even and smooth with thin layer of sagol, complete all as specified and directed. 37 Material & Labour for cement plaster rendering 5mm thick in cement mortar 1:3 on fair faces of brickwork or concrete surface of ceilling, finished even and smooth with thin layer of sagol, complete all as specified and directed. 38 Material & Labour for cement plaster rendering 15mm thick on fair faces of brickwork or concrete surfaces with two coats i.e. 10mm thick backing coat in cement mortar 1:6 and 5mm thick finishing coat in cement mortar 1:4and mixed with Water Proofing Compound, finished even and smooth without using extra cement, complete all as specified and directed.(Note -WPC to be measured and paid separately) 39 Raking out joints / pointing to squared rubble masonry coursed or uncoursed built in cement mortar or cement lime mortar, complete all as specified and directed. 40 Keyed pointing on squared rubble masonry coursed or uncoursed (Bangalore Pattern) in cement mortar 1:4 complete all as specified and directed. 41 Material & Labour for Preparation of newly plastered surfaces of ceiling and applyingthree coats of white washing, complete all as specified and directed. 42 Material & Labour for forPreparation of newly plastered surfaces of walls and applying three coats of white washing, complete all as specified and directed. 43 Material & Labour for Preparation of newly plastered surfaces of walls and applying two coats cement base paint on walls over a coat of alkali resistant primer, complete all as specified and directed. 44 Material and labourfor Preparation and complete removal of existing treatment of old plastered or unplastered surface, brooming down or steel wire brushing down smoke soot, moulds mass, efflorescent, trading, oil, greasy spots and applyingone coat of white wash complete all as specified and directed. 45 Material and labourfor Preparation and complete removal of existing treatment of old decoratedplastered or unplastered surface, brooming down or steel wire brushing down smoke soot, moulds mass, efflorescent, trading, oil, greasy spots and applying one coat of cement based paint complete all as specified and as directed. 46 Material & Labour for Repair to ends of chajjas/ parapets by removing old concrete,loose material &cleaning of the reinforcement and finishing the surface with rich cement mortar 1:3 , finished fair & even and making good (area not exceeding 3 Sqm) with existing finishes complete all as specified and as directed.Note : Rate quoted by the tenderer shall be deemed to inclusive of double steel scaffolding. 47 Supply & Fixfrosted glass 4 mm thick, pin head typenot exceeding 0.5 Sqm in each pane and fixed, completeall asspecified and directed. 48 Supply & Fix4 mm thick sheet glass ordinary quality and glazing complete in square not exceeding 0.50 Sqm each,all as specified and directed. 49 Supply & Fixin repairs15mm bore stop / angle valves chromium plated cast copper screwed down high pressure fancy type screwed both ends for pipe or union fixed, complete all as specified and directed. 50 M&L two coats of synthitic enamel paint over a priming coat of pink primer incl preparation untreated surfaces of wood or wood based material exceeding 10 cm width or girth, complete all as specified and directed. 51 Demolition and bracking up drain pipes 75/100 mm dia (salt glazed ware, AC or PVC, reinforced concrete) set in cement mortar including bend and dimension piece etc, complete all as specified and directed. 52 Demolition and bracking up drain pipes 150 mm dia (salt glazed ware, AC or PVC, reinforced concrete) set in cement mortar incl bend and dimension piece etc, complete all as specified and directed. 53 Supply & Fix110mm bore PVC pipe (SWR) single socketed in any length with rubber ring joints fixed to wall,complete all as specified and directed. 54 Supply & Fix150mm bore PVC pipe (SWR) single socketed in any length with rubber ring joints fixed to wall,complete all as specified and directed. 55 Supply & Fix75mm bore PVC pipe (SWR) single socketed in any length with rubber ring joints fixed to wall / floors,complete all as specified and directed. 56 Supply & Fixfor PVC (SWR) bends of 150mm bore of pipeprovide with or without access door, complete all as specified and directed. 57 Supply & Fixfor PVC (SWR) bends of 110mm bore of pipeprovide with or without access door, complete all as specified and directed. 58 Supply & Fixfor PVC (SWR) branch piece,single (single Y) equal or unequal bore of pipe 110mm, complete all as specified and directed. 59 Supply & Fixfor PVC (SWR) bends of 75mm bore of pipeprovide with or without access door, complete all as specified and directed. 60 Supply & FixforPVC (SWR) branch piece, single (single Y) equal or unequal bore of pipe 75mm, complete all as specified and directed. 61 Material & Labour for in repairs PVC (SWR) floor trap, plain with grating including jointing with solvent cement of dia of outlet 75 /110mm, all as specified and directed. 62 Material & Labour for in repairs PVC (SWR) gully trap, plain with grating including jointing with solvent cement of dia of outlet 110 / 125mm, all as specified and directed. 63 Taking up or down 15 / 20 / 25mm bore of GI pipe steel tubing / CPVC pipes and connections, complete all as specified and directed. 64 Supplying and laying of CPVC 16mm dia pipes SDR 11 & Plain CPVC SDR 11 fittings on walls / ceiling or laying in floors, complete all as specified & directed. 65 Taking up or down 32 / 40/50mm bore of GI pipe steel tubing/CPVC pipes and connections, complete all as specified and directed. 66 Material & Labour for for25 mm bore steel tubes “medium grade” galvanised with all fitting and fixed complete in walls ceiling or laid in floors, complete all as specified and directed. 67 Material & Labour for for40mm bore steel tubes “medium grade” galvanised with all fitting and fixed complete in walls ceiling or laid in floors, complete all as specified and directed. 68 Material & Labour for in repairs 40 mm dia gun metal gate valve with Iron wheel screwed both ends for Iron pipe, complete all as specified and directed. 69 Material & Labour for Cutting grooves 75mm wide and 65mm deep in brick / stone wall for forpipe, and shaping horizontal face of groove with cement mortar 1:3, complete. 70 Supply & Fixin repairs15mm bore stop value of PTMT of any colour screwed for iron / UPVc pipe complete all as specified and directed. 71 Supply & Fixin repairs PVC connections 15mm size with PTMT nuts of length 600 mm, all as specified and as directed 72 Supply & Fixin repairs PVC connections 45 cm long incl 15 mm bore fly nuts on both ends, complete all as specified and directed. 73 Supply & Fixin repairs 40mm bore unplasticised PVC pipe of pressure rating 10 kg / Sqcm fixed complete to walls, ceiling or laid in floors complete all as specified and directed. 74 Supply & Fixin repairs high/low level cistern with brackets flush pipe etc complete and supply and fixing PVC low level cistern syphonic action type including inlet ball valve float and handle including brackets of approved make including all connections & flush pipes for EWC & indian type WC, complete all as specified and directed. 75 Supply & Fixin repairs 450 x 600 mm belevelled edge mirror 5 mm thick of selectd quality glass mounted on 6 mm thick PVC / AC bldg board or commenrial ply wood and fixed to wooden plugs with CP brass screws and cup washer,complete all as specified and directed. 76 Supply & Fixin repairs viterous china wash down water closet (Pedestral pattern) EWC white incl plastic water closet seat cover and mild steel chromium plated or aluminium hinging device and connecting to P or S trap including connecting flush pipe with flushing rim, complete all as specified and as directed. 77 Supply & Fixin repair fancy typebrass chromium plated shower rose 125 mm dia size with arm, complete all as specified and directed. 78 Supply & Fixin repairs15mm borePush cock chromium plated cast copper screwed down high pressure fancy type screwed both ends for pipe or union fixed, complete all as specified and directed. 79 Supply & Fixin repairs Health faucet Chromium Plated for iron pipes 15 mm bore & 1.5 mtr long, with all accessories complete all as specified and directed. 80 Supply & Fixin repairs 40 mm waste coupling fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed one, complete all as manufactures and all as specified 81 Supply & FixRotational moulded Polyethylene water storage tank - 2000 liters capacity(three layer white colour) cylindericalvertical with closed top including 3 Nos GI check nuts and tank nipple of 25 / 40mm bore for inlet and outlet, 25mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball hoisted and fixed in position all as specified in SSR part - I including dismantling taking down of old unserviceable tank, complete all as specified and directed. 82 Supply & FixRotational moulded polythene water storage tank of1000 Ltrs capacity (three layer white colour) cylindericalvertical with closed top including 3 Nos GI check nuts and tank nipple of 25 / 40mm bore for inlet and outlet, 25mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball hoisted and fixed in position all as specified in SSR part -I including dismantling taking down of old unserviceable tank, complete all as specified and directed. 83 Treatment of the sunken floor slab comprises of the following specification and all as specified :-(a) Demolition of cement concrete filling of any description in sunken portion in toilet and removing debris outside MD land.(b) Cleaning the sunken/ lowered portion of RCC slab surfaces (including vertical total depth plus skirting height) of floors by wire brush, chisel out any mortar sticking to the surface and brooming completely. 40mm thick avg PCC 1:2:4 type B-0 (using 12.5mm graded stone aggregate) as in padding concrete to achieve proper slope including cutting holes in bricks or RCC wall for spout 84 (c) Rendering of uneven surfaces with 10mm thick cement mortar 1:4 mixed with integral water proofing compound as per manufacturers instruction. Fill it with water and check dampness and seepage. Where dampness/ seepage is noticed, nozzles shall be fixed and grouting carried out. (d)All junctions points of side wall spout where CI / GI pipes are passing through shall be sealed with epoxy putty.(e)After drying putty, wash the slab and sides of sunken portion with water and make it clear and clean. 85 (f) Material and labourfor applying two coats of polymer modified cementious water proof coating as per manufactures instruction to bottom and vertical sides up to finished floor level+100mm height. The thickness of two layer shall be 1mm. When the second layer is still sticky, coarse sand spray shall be carried for the vertical and bottom surface of the sunken portion all as specified and directed.(g)Plaster the bottom and sides up to bottom of the skirting with minimum 20mm thick cement mortar 1:4 mixed with integral water proofing compound 3% by wt of cement consumed as per manufacturers specification including rounding of corners and junctions sloping towards spout. 86 (h)Material and labourfor Plain Cement Concrete 1:5:10 type E2, 150mm thick, complete all as specified.(j) Material and labourfor PCC 1:2:4 type B0 12.5mm thick aggregate, 50mm tnick complete all as specified.Note:-(i)Test the water proof area (ponding test) by filling water for at least 72 hours and tested for leakage, seepage to the entire satisfaction of GE. The treatment shall be carried out by authorised applicator of chemicals. Cost of testing is included in the unit quoted rate above.(ii)WPC shall be measured & paid separately. 87 SupplyOnly integral water proofing compound complete all as specified and as directed. 88 Material and labourfor Water proofing treatment to the sunken portion applying two coat of two component (1 part Polymer and second part cementations powder) cementations, polymer modified elastomeric, water proofing coating composed of cement, properly selected and graded aggregates, additive and acrylic emulsion polymer as a binder apply first coat of (mix and application as per manufacturer’s instructions) all over floor surface.Following application shall be carried our thereafter :-(a) Preparation of surface and apply to vertical surface up to 15cm from tiling level, allow to dry 4 to 6 hours. (b)Prepare for apply 2nd coat perpendicular to first coat and allow to dry 4 to 6 hours. (c)All joints to Trap / WC / Soil pipe shall be properly sealed with ceiling compound / polymer modified mortar using Dr Fixit Pidicrete UBP or equivalent in M/s Pidilite orM/s Sika Chemical, Slope of slab shall be towards and including GI pipe 50mm dia of suitable length Spout pipe. Providing 15mmprotective screed with cement mortar in 1.3 with WPC (Make : Dr Fixit LW + or equivalent in M/s Pidilite orM/s Sika Chemical) within 2 to 3 days of second coat complete all as specified as per manufacturer instructions. Make : Dr Fixit Pidfin 2K or equivalent in M/s Pidilite orM/s Sika Chemical complete all specified and directed. 89 M&L for Dismantling/ taking down old existing unserviceable cement plaster, loose/ unsound weaken cement concrete of any description and in any position from existing external / internal surface of RCC roof/ slab/ beams/ columns/ RCC facias for an average depth of 25mm (Approx height 7.5m from natural ground level) with power driven pneumatic flat/pointed chisel and removing the honeycombed area including all the corners and making a neat profile of the cavities, roughen the smooth surface , scrapping out / removing corrosion all loose / scale / rust etc form the visible reinforcement by applying rust remover such as Rust Off 100 of make M/s Sika India Pvt Ltd, or equivalent in M/s Fosroc Chemicals / M/s Choksey Chemicals Pvt / M/s BOSTIk India pvt limited / M/s STP Limited / M/s ThermaxLimited ( as approved by GE) and cleaning the steel reinforcement properly all as manufactures and with followinf application :- 90 (a) Providing cement based angle fillet for 75mm X 75mm admixed with Sikacim, integralwaterproofing liquid M/s Sika India Pvt Ltd, or equivalent in M/s Fosroc Chemicals, M/s Choksey Chemicals Pvt., M/s BOSTIk India pvt limited, M/s STP Limited, (as approved by GE) @ 0.2% by weight of cement or as per manufacturer’sinstructions over a coat of acrylic emulsion bonding agent such as per as Sika Latex in 1:1:3 ratio of Make M/s Sika India Pvt Ltd, or equivalent in M/S Fosrox chemicals, M/s Choksey Chemicals Pvt., M/s BOSTIkIndia pvt limited, M/s STP Limited, M/s Thermex Ltd (as approved by GE) having specific gravity of 1.02 or as per manufacturer’s instructions with necessary surface preparation such as creating mechanical key like roughing the surface by scrabbing, grit blasting and cleaning the existing surface using high pressure water jet machine having pressure upto 500 barpressure to remove the dirt, dust, loose particles , wax, efforencene and other contaminations from the surface of RCC columns/ beams/ slabs/ facia/ any brick/ stone surfaces etc all as manufactures and all as specified and directed. 91 (b) Providing and applying FRIAZINC R, corrosion inhabiliting Active Zinc rich primer of make M/s Sika India Pvt Ltd, or equivalent in M/s Fosroc Chemicals, M/s Choksey Chemicals Pvt., M/s BOSTIk India pvt limited, M/s STP Limited, M/s Thermex Ltd (as approved by GE) along the exposed reinforcement surface property and allowed to dry. 92 (c)Providing and applying Hibond, Epoxy based Thixotropic bonding adhesive of Make of M/s Sika India Pvt Ltd, or equivalent in M/s Fosroc Chemicals, M/s Choksey Chemicals Pvt., M/s BOSTIk India pvt limited, M/s STP Limited, ( as approved by GE) over the prepared concrete surface to get a good bonding between existing concrete surface and providing Sika Rep Microcrete 4 Fiber reinforced cementitious repair micro concrete of make M/s Sika India Pvt Ltd, or equivalent in M/s Fosroc Chemicals, M/s Choksey Chemicals Pvt., M/s BOSTIk India pvt limited, M/s STP Limited, M/s Thermex Ltd ( as approved by GE) over Epoxy based bonding agent applied area before 6 Hrs etc including providing necessary proportions , bracing and runners to relieve the member from the load coming on it including scaffolding leak proof shuttering with working platform as required and as per design and pattern complete including preparing the surface to match with the existing surface all as specified and directed. 93 Note :-(i)The work under shall be carried out through authorized and qualified applicators of the any following manufacturer only. MOU to be submitted before commencement of work between contractor and manufacturer.(ii)A performance guarantee certificate for two years shall be submitted by the contractor to the GE on completion of work as specified. (iii) The unit rate quotedis deemed to be included for Removing of accumulated earth of any width and depth upto 15 cm cleaning/cutting the grass with hand operated petrol/kerosene driven grass cutting machine and removing the grass waste around 3 m from plinth protectionto outside MD land Note: Periodicityof cutting of grass shall be before commencement of work and after completion of repairs. 94 Supply & Fixin repairs Bib Tap 15mm bore (dia), Cast Copper alloy, Chromium Plated, Fancy type, Short/long Body with Capstan Head, screwed down, screwed for Iron Pipe or for Brass Ferrule, complete all as specified and as directed. 95 Supply & Fixin repairsstop valves fancy type chromium palted with long shank and cup ( concealedtype ) screwed for iron pipe/CPVC of 15 mm bore, complete all as specified and directed. 96 Supply & Fixfor Chromium Plated soap dish fixed to wall with chromium plated brass screws, complete all as specified and directed. 97 Supply & Fixin repair waste coupling 32mm dia of PTMT (half or full thread) minimum weight 45 gram, complete all as specified and directed. 98 Supply & Fixin repairs PVC waste pipe 32mm bore for WHB / urinal, all as specified and directed. 99 Material & Labour for core cutting of size 50mm dia in stone wall with the help of machine and preparing surface to make good matchingwth existing surfacecoloured, complete all as specified and directed 100 Material & Labour for core cutting of size 100mm dia in stone wall with the help of machine and preparing surface to make good matchingwth existing surfacecoloured, complete all as specified and directed 101 Material & Labour for 100 mm thick Plain Cement Concrete1:2:4 type B-1 (using 20mm graded crushed stone agg) as in PCCin hard standing etc.with spike rolling or making impression of expanded metal, while the concrete is green, complete all as specified and as directed. 102 Material & Labour for 75mm thick Plain cement concrete 1:3:6type C1 (using 20 mm graded stone aggregate), as in plinth protection courses, top surface of concrete finished even and smooth with out using extra cement, complete all as specified and directed 103 Material & Labour for reinforced concrete pipes 200mm bore, class NP2, laid and jointed with collars, complete all as specified and as directed. 104 Material & Labour for cement concrete 1:4:8 type D2 (using 40 mm graded stone aggregate) in bed to pipe including forming cradles 200mm internal dia after the pipes are laid jointed and tested complete complete all as specified and as directed. 105 Demolition of brick work or stone / boulder masonry/pcc block, built in cement mortar or cement lime mortar incl aii quoins, arches, pillars, etc., but excluding ashlar facings, dressed stonework and precast concrete articles and removing debris, etc. to outside defence land, complete all as specified and as directed 106 Demolition of reinforced cement concrete in any description and in any position not otherwise specifically provided for and removing debris, etc. to outside defence land, complete all as specified and as directed 107 Demolition of cement concrete (unreinforced) of any description in ground floor not otherwise specifically provided for and removing debris, etc. to outside defence land, complete all as specified and as directed 108 Demolition and breaking up 200mm dia drain pipes (salt glazed ware, AC or reinforced concrete) set in cement mortar complete all as specified and as directed. 109 Taking down carefully copper / aluminum pointwiring(light, fan, Power) completefittings such as switches , ceiling roses pendents , regulatorssocketslight fittingsetcremoving materials to store for keeping in safe custody or for taking creditand making good disturbed surface of wall, floors, roofetc all as specified. 110 Taking down carefully copper/aluminum sub main wiring,removing materials to store for keeping in safe custody or for taking creditand making good disturbed surface of wall, floors , roofetc all as specified. 111 Material and labourfor Point wiring complete with 1. 5 Sq mm single Core PVC insulatedFRLS cable, 1100 volts grade unsheathed with multi stranded copper conductor drawn through and including PVC rigid non metalic conduit on surface/concealed with all fittings such as bend, end caps etc fixed on the surface of wall, ceiling, roof, steel structure etc. by means of suitable fixing accessories including provision of 1.5 Sq mm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor for earth continuity conductor, modular metal pressed flush box concealed in wall,including suitable modulesmodular whitetop cover and plate for housing the switches, sockets, regulators etc, forOne light point controlled by one switch one way 6 Amps, all asspecified and directed. Note :Cost of for cutting chasing, metal flush in the wall for box and making good to disturbed surface all as to match with existing surface are deemed to be included in quoted rate. 112 Material and labourfor Point wiring complete with 1. 5 Sq mm single Core PVC insulatedFRLS cable, 1100 volts grade unsheathed with multi stranded copper conductor drawn through and including PVC rigid non metalic conduit on surface/concealed with all fittings such as bend, end caps etc fixed on the surface of wall, ceiling, roof, steel structure etc. by means of suitable fixing accessories including provision of 1.5 Sq mm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor for earth continuity conductor, modular metal pressed flush box concealed in wall,including suitable modulesmodular whitetop cover and plate for housing the switches, sockets, regulators etc, for One Exhaust fan point controlled by one switch one way 6 Amps, all asspecified and directed. Note :Cost of for cutting chasing, metal flush in the wall for box and making good to disturbed surface all as to match with existing surface are deemed to be included in quoted rate. 113 Material and labourfor Point wiring complete with 1. 5 Sq mm single Core PVC insulatedFRLS cable, 1100 volts grade unsheathed with multi stranded copper conductor drawn through and including PVC rigid non metalic conduit on surface/concealed with all fittings such as bend, end caps etc fixed on the surface of wall, ceiling, roof, steel structure etc. by means of suitable fixing accessories including provision of 1.5 Sq mm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor for earth continuity conductor, modular metal pressed flush box concealed in wall,including suitable modulesmodular whitetop cover and plate for housing the switches, sockets, regulators etc, for One 2/3 pin switch socket point controlled by 6 Amps switch on Independent board, all asspecified and directed. Note :Cost of for cutting chasing, metal flush in the wall for box and making good to disturbed surface all as to match with existing surface are deemed to be included in quoted rate. 114 Material and labourfor Point wiring complete with 1. 5 Sq mm single Core PVC insulatedFRLS cable, 1100 volts grade unsheathed with multi stranded copper conductor drawn through and including PVC rigid non metalic conduit on surface/concealed with all fittings such as bend, end caps etc fixed on the surface of wall, ceiling, roof, steel structure etc. by means of suitable fixing accessories including provision of 1.5 Sq mm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor for earth continuity conductor, modular metal pressed flush box concealed in wall,including suitable modulesmodular whitetop cover and plate for housing the switches, sockets, regulators etc, One socket out let 6 Amps 3 pin on same board, all asspecified and directed. Note :Cost of for cutting chasing, metal flush in the wall for box and making good to disturbed surface all as to match with existing surface are deemed to be included in quoted rate. 115 Material and labourfor Point wiring complete with 4 Sq mm single Core PVC insulatedFRLS cable, 1100 volts grade unsheathed with multi stranded copper conductor drawn through and including PVC rigid non metalic conduit on surface/concealed with all fittings such as bend, end caps etc fixed on the surface of wall, ceiling, roof, steel structure etc. by means of suitable fixing accessories including provision of 4 Sq mm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor for earth continuity conductor, modular metal pressed flush box concealed in wall,including suitable modulesmodular whitetop cover and plate for housing the switches, sockets, regulators etc, for One 3 pin switch socket outlet combination, 15 Amps,all asspecified and directed. Note :Cost of for cutting chasing, metal flush in the wall for box and making good to disturbed surface all as to match with existing surface are deemed to be included in quoted rate. 116 Supply & Fixin Replacement Modular Switch 1 way 6 A, 1 Module all as specified and directed 117 Supply & FixModular Switch 1 way 16 A, 1 Module all as specified and directed. 118 Supply & FixModular socket 6 A, - 2/3 pin combined 2 module all as specified and directed. 119 Supply & FixModular socket 6/16 A, - 2 / 3 pin comb 2 module all as specified and directed. 120 Supply & fix in replacement of ceiling rose, surface bakelite type,PVC, 65 x 50 mm isolated body with three terminals all as specified and as directed. 121 Taking down of old unserviceable of exhaust fan of any size complete all as specified and directed. 122 Refixingexisting serviceable Exhaust fans 300/225 mm sweep servicing, paintingExhaust fan with one coat of synthetic enamel paint by spraying including greasing/oiling, fillingcavities with filler after cleaning all dust etc. completeall as specified and as directed by Engineer-in-Charge. 123 Supply and fixing in replacement Exhaust fan 300 mm sweep, 230/240 volt AC single phase, metal Body, 1400 RPM, with blade,frame , louvers including core cutting hole on stone masanery (Machine cutting) suitable for fixing exhaust fan with suitable nuts bolts and louers and make good the surface to match with existing surface complete including taking down old unsv all as specifed and directed. (Note- Old us exhaust fan will be deposited to mes store yard.) 124 Taking down of old electric water heater of any size complete all as specified and directed. 125 Refixingexisting serviceable Electric water heater with one coat of synthetic enamel paint by spraying after cleaning all dust etc. completeall as specified and as directed. 126 Supply and fixing in replacementelectric water heater,storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc including connecting up electrical , heat,cold water connections and testing complete all as specified and directed.( Note- Old us water heater will be deposited to mes store yard.) 127 Supply and Fixsingle pole and earth enclosure with a three pin and earth plug and socket complete with one double pole RCBOs 10- 20 Amps with complete accessories all as specified and as directedand directed by Engr in Charge as per site requirement. 128 Material & Labour for sub main wiring with 2 single core stranded copper conductor unsheathed PVC insulated cable 1100V grade 4 Sqmm drawn through suitable size of non-metallic PVC rigid conduit with 1x 4sqmm copper conductor cable as earth conductor and conduit accessories fixed up in surface/recessed as required, connection up and taking down old wiring complete all as specified and directed. 129 Material & Labour for sub main wiring three phasewith 2.5 single core stranded copper conductor unsheathed PVC insulated cable 1100V grade, 2.5 Sqmm drawn through suitable size of non-metallic PVC rigid conduit with 2.5 sqmm copper conductor cable as earth conductor and conduit accessories fixed up in surface/recessed as required, connection up and taking down old wiring complete all as specified and directed. 130 Supply and fixing in Replacement 4 ft LED batten, wattage 20 w, having minimum lumenefficiency 100 lume/watts, surgeprotection and wide operating voltage range - 140V to 270 V , LED has colour Temperature of between4500K to 6500k with diffuser, IP 20, Aluminium Housing with all accessories internally Pre wired and including connecting up with 2/3 core twisted flexible copper conductor cable 0.75 sq mm from ceiling to fitting, mounted on roof/wall etc. on PVC round bush of suitable approved size at as specified and as directed 131 Supply and fixing in Replacement 2 ft LED batten, wattage 10 w, having minimum lumenefficiency 100 lume/watts, surgeprotection and wide operating voltage range - 140V to 270 V , LED has colour Temperature of between4500K to 6500kwith diffuser, IP 20, Aluminium Housing with all accessories internally Pre wired and including connecting up with 2/3 core twisted flexible copper conductor cable 0.75 sq mm from ceiling to fitting, mounted on roof/wall etc. on PVC round bush of suitable approved size at as specified and as directed 132 S&F in Replacement MCB DB SPN 8 WAY , horrizontal, double door, 240 V, AC,50 Hz, for MCB DP as incommer and and SP MCBs as out going.IP- 43 protectionuniversal mounting with copper busbar, neutral link, earth link, earthing shuds all as specified and directed 133 Supply & Fixin Replacement MCB single pole240 volts 6 to 32 Amps, 10 KA rupturing capacity.B series all as specified and as directed. 134 Supply & Fixin Replacement MCB single pole and neutral 240 volts 40 to 63 Amps, 10 KA rupturing capacity.B series all as specified and as directed. 135 Material and labour for Earth pit cover madeof heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 7.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mm for each electrode pit complete including taking down old unserviceable pit cover of any decription all as specified and directed.(Make : Model SEPC 250 of SAFE TRODE or equivalent in Snaga/ Cubes 6 Global) 136 Supply & Fixin repair copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc including taking down existing old unserviceable copper strip etc, complete all as specified anddirected. Note : - All Joints should be joined by Exothermic Welding or Brazing. 137 Supply, installation, testing & commissioning of maintenance free chemicalearthing system comprising of 17mm dia copper bondedrod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducingliquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 Amp by any NABL accredited lab. The above mentioned rod shall be installed in 4-6 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation including taking down existing one, complete all as specified and directed.(Make : Model HTSP 317 of safeTrode or equivalent in OBO Betterman/ FURSE/ERICO)The quoted rate shall also deemed to be included the following :- 138 (i)Prior toinstallation of maintenance free chemicalearthing, soil resistivity test to be carried out at the location where earthingwork to be donein presence of Engr-in- Charge/JE (E/M),user and the report has tosubmitto Garrison Engineer with recommendation of manufacturer, if required additional interconnection ofearthing (not more than 04 number of earthing) to achive earth result less then 1 Ohms. The arrangement done for soil resistivity testingandsubmission of report with recommendationdeemed to be included in the quoted rate.(ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors.(iii) Rateofearth energizer compound of 25 Kg of 02 bags and earthresistance reducingliquid 10 litre per cane for each pit deemed to be included in the quoted rate. 139 (iv)Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor before commencement of work. (v) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH value should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete.(vi) Copper strip of size 20 x 3 mm shallbe fixed on proper post insulator at the instrument end ( copper strip upto 7.5 RM shall be considered in unit quoted rate and extra will be measured and paid separately).(vii)Testing of earth shall be carriedout in presence ofdepartmental and user representativeand report shall be submitted to Garrison Engineer duly signed by all concerned. 140 (viii)Earth resistance tester will be provided by the contractor.Tester should be calibrated from authorised company/ lab.(ix)Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintained duly signed by all concerned.After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained. (x) The contractor shall give a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion.(xi) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including soft/ disintegrated or hard rock. (xii) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is maintained. 141 (xiii) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing for each earthing shall be retained from payment due to the contractor from final bill for the guarantee period.(xiv) The electrode shallcarry manufacturers name. (xv) The connection clamp shall be permanentlly welded to the copper boundedrodto avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination.(xvi)The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm.(xvii)Earth work such as auguring andmaking good the surrounding area shall carried out in any type of soil. (xviii)The contractor shall submit CPRI India certified document for copper bounded rod to ensure genuineness of material. (xix) Sign boardof mild steel sheet 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxideZinc chrome primer showing result of earthing shall be fixed near the earth pit after completion as directed by Engr -in- charge.
Contract Date : 29 Oct, 2025   |   Contract Value : 65.03 Lakhs
Disclaimer

We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.

Tender Detail
Website https://tender.nprocure.com/
Quantity
MSME Exemption No
Tender Type Open Tender
Startup Exemption Click Here
Competitive Bidding NCB
Similar Tenders
TENDER INSIGHTS

858

Electric Tenders
Live
CLICK TO KNOW MAXIMUM WIN

Tell us about your Product / Services,

We will Find Tenders for you

🇮🇳 +91
TenderDetail
Loading tenders