Renovation Of Electrical and mechanical Equipment At Notto Centre (4Th & 5Th Floor Of Niop Bldg.) At S.J. Hospital New Delhi.-1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. 1.1 Group C 2 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. 2.1 Group C 3 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. 3.1 Group C 4 Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 4.1 25 mm 5 Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 5.1 3 x 1.5 Sqmm 5.2 3 x 4 sq. mm 5.3 6 x 4 sq. mm 5.4 3 x 6 Sqmm 5.5 6 x 6 sq. mm 6 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 6.1 1 or 2 Module (75mmX75mm) 6.2 3 Module (100mmX75mm) 6.3 6 Module (200mmX75mm) 6.4 8 Module (125mmX125mm) 6.5 12 Module (200mmX150mm) 7 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required 7.1 5/6 A switch 7.2 3 pin 5/6 A socket outlet 7.3 15/16 amp switch 7.4 6 pin 15/16 amp socket outlet 8 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 8.1 Data socket outlet 9 Supplying and fixing following rating, Triple pole, 415 V MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. 9.1 63A TPN MCB 10 Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required 10.1 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 11 Supplying and fixing following sizes PVC trunking on the surface including accessories end cover internal/External Corner Covers, T & intersections Covers etc complete as reqd. 11.1 100/105mm x 50mm with partition & cover 12 Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C. Bending Radius : < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force : 11.5Kg etc. complete as required. 12.1 1 run of cable 13 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required 13.1 Single pole 14 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 14.1 6 way (4 + 18), Double door 15 Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS / HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy 105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) 15.1 36 Watt 16 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required. 17 Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS / HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. 17.1 1200mm, service value 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) 18 Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required 19 Supplying, installation, testing & commissioning response indicator on surface / recess MS box having two LEDs metallic cover complete with all connections etc. as required. 20 Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. 21 Supply and Fixing installation, testing and commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core in confirmation to SMACNA/IS and as per specifications complete etc. as required. 22 Supply and Fixing installation, testing and commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core in confirmation to SMACNA/IS and as per specifications complete etc. as required 23 SITC of following types heavy duty propeller tube exhaust fan at following locations having dynamically balanced impellers & vibration free operation, 1400 RPM, pre lubricated double ball bearing rated voltage 220/240 Volts, 50 Hz, 1-ph AC having Class E motor insulation i/c wiring complete with 1.5 sqmm FR PVC insulated copper conductor, single core cable etc complete as required at site 23.1 300 mm sweep 24 SITC & Replacement of surface & wall mounted 10W mirror light of 600mm with polycarbonate housing, CRI>80K the luminaire rated life (L70B50)> 50000/- Hrs. with inbuilt Protection against short circuit and Surge Protection up to 2.5 KV, PF> 0.90, CCT 5700 K light complete with all accessories etc. including connection with 3 x 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and earthing etc. as required. 25 Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories : 25.1 Pendent Sprinkler 26 Supply, Installation, Testing, Commissioning & replacement of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe, R-32/R-410/ R- 407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). Inverter Type 26.1 2 TR with 5 Star BEE Rating 27 Supply, Installation, testing and commissioning i/c vaccumiazation and Nitrogen testing off following nominal sizes of soft / hard drawn copper refrigerant piping for Split AC, complete with fittings with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 27.1 6.4 mm dia(OD)(Softdrawn) with tube thickness 1.2 mm with 19 mm thick insulation 27.2 15.86 mm dia(OD)(Softdrawn) with tube thickness 1.2 mm with 19 mm thick insulation 28 Supply & fixing 3 core 2.5 sq.mm PVC insulated & XLPE sheathed unarmoured copper cable in surface (ISI) i/c thimling, testing, commissioning etc complete as required at site. 29 Supplying & Installation of Drain Piping having material UPVC Hard / Soft pipe of following size with accessories e.g. elbows, unions, sockets, reducers as per site requirement etc complete as required. 29.1 25 mm dia 30 Dismentalling of existing fans, Lights, wiring, DB, power points, light points, switch board, conduits, cable, panel etc complete during excution of this work as required. 31 Supply & Fixing of MS powder coated stand for Split AC on wall/ floor mounted i/c drilling holes, fixing with fastner & testing, comissioning etc complete as required. 32 Supplying, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/ round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, bends, transitions, reducers, end caps, collars etc as required complete in all respect in confirmation with IS : 655 and approved drawings and specifications of following sheet thickness complete as required. 32.1 Thickness 0.63 mm sheet 33 Less Credit for old dismental material 33.1 Wire 33.2 Switch Socket 33.3 Assorted DB with SP MCB 33.4 2 x 2 LED Fitting 33.5 Ceiling Fan 33.6 Exhaust Fan 33.7 Supply and Return Diffuser