Electrical Works At Frhphm Laboratory (Room No. 13, 210-A & 210-B) At New Campus, Icar-Cife, Mumbai.

Tender Notice

52590168
Central Public Works Department
Electrical Works At Frhphm Laboratory (Room No. 13, 210-A & 210-B) At New Campus, Icar-Cife, Mumbai.
Indian
Maharashtra
26-11-2025
04-12-2025
04-12-2025

Tender Details

Electrical Works At Frhphm Laboratory (Room No. 13, 210-A & 210-B) At New Campus, Icar-Cife, Mumbai.-(Internal EI & Fans) 1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 1.1 Group C 2 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel / PVC conduit as required. 2.1 3 x 1.5 sq. mm 2.2 3 x 4 sq. mm 2.3 6 x 4 sq. mm 3 Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 3.1 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 3.2 4 X 6 sq. mm + 2 X 6 sq. mm earth wire 3.3 4 X 16 sq. mm + 2 X 6 sq. mm earth wire 4 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 4.1 2 pair 5 Supplying and drawing of UTP 4 pair cat 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit/ channel as required 5.1 1 run of cable 5.2 2 run of cable 6 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 6.1 20 mm 6.2 25 mm 7 Supplying & fixing DLP U - PVC trunking of following size on the surface / ceiling i/ acessories (bends, Internal Corner, External Corner, Tee, Flat Angle, Joints & End caps) and straight flexible cover and seperator partition etc complete as reqd. 7.1 100 mm wide x 50 mm deep (2 Compartments) 7.2 50 mm wide x 50 mm deep (1 Compartment) 8 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 8.1 Telephone socket outlet 8.2 Internet socket RJ 45 information outlet for cat6 with shutter 8.3 25 Amp. Modular Socket Outlet (For AC/ Geyser point) 8.4 25 Amp. Modular SP MCB C Curve, 10 KA (For AC/Geyser point) 8.5 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 8.6 1 or 2 Module (75mmX75mm) 9 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/ amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. 10 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 11 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 3 Nos. 3 pin 5/6 A modular socket outlet and 1 No. 15/ 16 A modular switch, connections etc. as required. (For Computer Points) 12 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12.1 12 way , Double door 13 Supplying and fixing of following ways surface/ recess mounting, Vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) (with provision for 160 Amp. TP MCCB as incomer but without MCCB) 13.1 4 way (4 + 12), Double door 14 Supplying and Fixing Following way, Horizontal Type Three Pole and Neutral, Sheet Steel, MCB Distribution Board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 14.1 4 way (4 + 18), Double door 15 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 15.1 Single pole 15.2 Double pole 15.3 Triple pole 16 Supplying and fixing following rating, 415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 16.1 63 Amp. Triple pole and Neutral 17 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel including drilling holes in cubicle panel, making connections, etc. as required. 17.1 100A, 16 KA,TP MCCB 18 Providing and fixing following rating and pole tempra plug with socket DB in sheet steel enclosure on surface or recess, making good the wall etc. as reqd. 18.1 32 Amp, 4 pole (Fan & Fittings) Supply, installation, testing & commissioning of 1200 mm x 65 mm x 60 mm size (approx.) surface/suspensed type linear LED fitting with CCT 5700/6500K with powder coated CRCA sheet housing having high efficiency diffuser with more than 85% transmittance with rated life of L- 70 @ 50000 hrs having system lumen output better than 4000 lumens and efficacy not less than 120 lumen/ watt with CRI>80, PF -0.95, THD< 10% & Driver efficiency> 90% etc. complete as reqd. 20 Panel light 2x2 ft. (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation,Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with ,70% of initial Lumen maintained LED till life ends,CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mm). 20.1 36 watt 21 LED Down lighter (SMD Type) (System lumen efficacy ≥120<135 lm/Watt Supplying,installation,Testing & Commissioning of LED Recessed / surface Down lighter (Round square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz,Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80,UGR (Unified Glare Rating) < 19, Flicker free (flicker should 1 be below 5 %), life time (LED,Driver & electrical circuitry), life time of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends ,CCT 3000°K/4000°K/5700° /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3,Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printingon housing.OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures.complete in all respect i/c connections with 1.5 sq mm FRLS,PVC insulated copper conductor single core cable and earthing etc. required with Minimum 5 year OEM warranty.System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminum Body including trim 21.1 8 - 10 watt 22 SITC of following sweep plastic body exhaust fan with inbuilt shutter in the existing opening suitable for operation on 230 V, 50 Hz single phase AC supply i/c making good the damage and connection with 3 x 1.5 sq.mm FRLS PVC insulated copper conductor etc as reqd. 22.1 200 mm 23 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos.blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 24 Supplying, Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R- 410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 degree celcius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 degree celcius (outdoor ambient temperature). Inverter Type - Cooling only 24.1 1.5 TR with 5 Star BEE Rating VRV/VRF System NIT.] 25 Supply, Installation, Testing & Commissioning of Modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling/heating having 100% hermetically sealed inverter type twin Rotary/Scroll Compressor(s),minimum two compressors (with individual separate PCB) for above 14HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R-410-A Refrigerant or equivalent, vibration Isolators with suitable foundation etc. complete as required. To have better efficiency condenser fan shall be capable to operate at different speed with respect to load. The unit shall deliver the rated capacity and in confirmation as per IS 18728:2024 and CPWD Specifications and work even at 50°C ambient temperature without tripping.The system shall be able to deliver 100% of the rated capacity upto 39 Degree Celcius.The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply and BMS compatible. The unit shall be filled with first charge of the refrigerant and ready for use as required. The condenser should be coated with a hydrophilic film to prevent water accumulation on the surface of the heat exchanger, enhance water dispersion, and reduce the risk of degradation, thereby improving overall performance and durability. The Indian Seasonal Energy Efficiency Ratio (ISEER) of the unit shall be as per Energy Conservation and Sustainable Building Code (ECSBC) 2024 as below and complete as per CPWD specification, connections, inter connections etc. as required. (For capacity <40 kWr ISEER 6.4, Capacity >40 and <70 ISEER 6.5, Capacity > 70 ISEER 6.6 for ECSBC+ Building) (Note: Each Unit shall be provided with anticorrosive coating) 25.1 14 HP to 22 HP 26 Supply, Installation, Testing and Commissioning of following minimum capacity 4 way Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan /dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration Isolation, Corded remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The Indoor units must shut down upon receiving a singal from the BMS System/Fire Signals. The system shall be capable to adjust air flow as per room requirement in auto mode. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. (Make will be same as of Outdoor) 26.1 3.6 TR 27 Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 27.1 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm 27.2 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm 27.3 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm 27.4 22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm 27.5 28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm 28 Supply, Installation, testing and commissioning of following nominal sizes of soft/hard drawn copper refrigerant pipe refinet (Y-type) for Suction and Liquid lines of VRV/VRF system, complete with fittings, with suitable jointing/brazing including all connection as per Specifications etc. as required. 29 Supplying and laying/drawing of 2 core x 1.5 sq.mm PVC insulated and sheathed, screened communication cable with annealed bare tinned copper conductor in the existing surface/ recessed steel / PVC conduit/on cable tray etc. as required.

Key Value

Document Fees
Refer document
EMD
INR 26802.0 /-
Tender Value
INR 13.40 Lakhs /-

Attachment

FileName File Description File Size Download
2aa3603a-f2f8-44f7-b02b-f180edbca83e.html Tender Documents 0 KB Download
DocumentsList.zip Tender Documents 0 KB Download

Other Information

Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail