Tender Summary / Eligibility Criteria
Tender For Replacement Of Defective Base Insulator For 122 Mts Guyed Mast At All India Radio, Bengaluru. Insulator Will Be Supplied By Air, Bengaluru.
Documents
Download All
No Boq
No Corrigendum
Probable Bidders
AI engine predicts probable bidders to help you bid strategically.
MSME Exception
Technical
Tender involves procurement of high capacity electrical equipment including diaphragm coupling of pump &
motor with 90kW capacity at 2900 RPM. The project scope includes installation, testing, commissioning and
operational handover.
Previous / Similar Result
BRR : 1947855
Repair / Maintenance Of Street Lights On Swan Neck Pole And High Mast Lights And Other Connected Items At Jne And Chnc Area Under Ge Utilities Udhampur - 1 Taking Down Carefully Unserviceable Of 70 Watt Street Liight / Security Light / High Mast Light Fitting From Pole / Structure And Repair / Replacement Of Worn Out Parts Such As Ballast, Lamp, Starter, Ignitor Etc, Cleaning Of Fittings, Cover, Copper Wire, Clamps, Nuts And Bolts, Mounting Bracket And Re Assembling The Same After Repair, Testing And Refixing In Pole / Other Location Including Provision Of Necessery T & P Like Ladder / Boom Vehicle, Tools Ets As Required For Taking Down And Refixing Of Street Light Complete All As Specified And Directed By Engr-In-Charge. Nnote: Replacement Of Defective Spare Parts Of Fitting ( To Make Functional ) Will Be Measured And Paid Separately As Supply Only. However, Cost Of Replacement Screws, Nuts, Bolts, And Cleaning Of Fittings Shall Be Deemed To Be Included In Quoted Rate. 2 Description All As Per Serial Item No 01 Here-In-Before But Hpsv / Mh Light Fittings 150 Watt Street Light Fitting. 3 Description All As Per Serial Item No 01 Here-In-Before But Hpsv / Mh Light Fittings 250 Watt Street Light Fitting. 4 Description All As Per Serial Item No 01 Here-In-Before But Hpsv / Mh Light Fittings 400 Watt Street Light Fitting. 5 Description All As Per Serial Item No 01 Here-In-Before But Hpsv / Mh Light Fittings 250 To 400 Watt Double Ended Lamp Street Light Fitting. 6 Supply Only Copper Wound Ballast Suitable For 70 Watt Hpsv / Mh Light Fitting Complete All As Specified And Directed By Engr-In-Charge. Nmake: Bajaj / Crompton / Philips 7 Description All As Per Serial Item No 06 Here-In-Before But Copper Wound Ballast Suitable For 150 Watt Hpsv / Mh Light Fitting. 8 Description All As Per Serial Item No 06 Here-In-Before But Copper Wound Ballast Suitable For 250 Watt Hpsv / Mh Light Fitting. 9 Description All As Per Serial Item No 06 Here-In-Before But Copper Wound Ballast Suitable For 400 Watt Hpsv / Mh Light Fitting. 10 Description All As Per Serial Item No 06 Here-In-Before But Lamp Suitable For 70 Watt Mh Light Fitting. 11 Description All As Per Serial Item No 06 Here-In-Before But Lamp Suitable For 150 Watt Mh Light Fitting. 12 Description All As Per Serial Item No 06 Here-In-Before But Lamp Suitable For 250 Watt Mh Light Fitting. 13 Description All As Per Serial Item No 06 Here-In-Before But Lamp Suitable For 400 Watt Mh Light Fitting. 14 Description All As Per Serial Item No 06 Here-In-Before But Lamp Suitable For 70 Watt Hpsv Light Fitting. 15 Description All As Per Serial Item No 06 Here-In-Before But Lamp Suitable For 150 Watt Hpsv Light Fitting. 16 Description All As Per Serial Item No 06 Here-In-Before But Lamp Suitable For 250 Watt Hpsv Light Fitting. 17 Description All As Per Serial Item No 06 Here-In-Before But Lamp Suitable For 400 Watt Hpsv Light Fitting. 18 Description All As Per Serial Item No 06 Here-In-Before But Electronic Igniters Suitable For 70 / 150 / 250 / 400 Watt. 19 Description All As Per Serial Item No 06 Here-In-Before But Capacitor 10 Mfd / 20 Mfd / 33 Mfd For Hpsv, Mv, Mh Lamp Fittings. 20 Taking Down Existing Old Pcc / Steel Poles Complete All As Specified And Directed By Engr-In-Charge. Nnote: Damaged Poles Shall Be Removed From The Site As Per Direction Of Engr-In-Charge. 21 Dismantling / Taking Down Of Old Unsv Acsr Conductor Of Any Size For Lt Oh Line, Earth Wire & Cradles Complete All As Specified And Directed By Engr-In-Charge. 22 Taking Down Existing Old Cross Arms Of Ms Channel Or Angle Sections Etc Complete All As Specified And Directed By Engr-In-Charge. 23 Dismantling Of Old Insulators Pin / Shackle Complete And Keeping Aside For Removal Complete All As Specified And Directed By Engr-In-Charge. 24 S&F In Replacement Erecting Steel Tubular Swaged Poles Erected To Truly Vertical Or Planted As Strut Complete With 6Mm Thick Mild Steel Base Plate ( 300Mmx300mm ) , Welded To Pole, Finial Taper Plug, Bolts, Nuts, And Screws Poles Made Out Of Erw Ms Tubing Conforming To Is-2713 Part-Ii Type 410 Sp-31, 9Mtr Long Including Drilling Of Holes Of Required Size For Fixing Of Cross Arms, Painting The Exposed Surfaces Of Pole With Two Coats Of Aluminum Paint Over A Coat Of Red Oxide Zinc Chrome Primer And With Two Coats Of Black Bitumenous Paint Internally And Portion Embedded In Concrete, Making Five Black & White Bands At Lower Portion Of Pole Each 300Mm Wide Alternately Upto The Height And Marking Pole No. With Black Paint At Suitable Height Including Making Two Nos Holes Of Suitable Size In Steel Tubular Pole By Gas Welding For Passing Pvc Cable Connection From Junction Box To Security Lights Through Pole Where Junction Box To Be Fitted In Pole Complete All As Specified And Directed By Engr-In-Charge. Nnote: Excavation And Earth Work, Pcc In Foundation Shall Be Measured And Paid For Separately. 25 Supply, Laying, Jointing In Replacement & Testing 1100 Volts Grade Heavy Duty Cable Pvc Tape Pvc Sheathed 2.5 Sqmm Aluminium Solid Conductor 2 Core Nominal Cross Section Laid In Trenches / Fixed To Walls / Passing Under The Roads In Existing Pipes Etc Including Takind Down Old Unsv Cable Complete All As Specified And Directed By Engr-In-Charge. 26 S&F In Replacement Modular Box Of Size 333 X 233 X 120 Mm Made Of Frp Inpact Resistance Plastic & Heat Resistant Materials Including Mcb Sp 6 A, Connector Terminal Block 4 Pole 16 A Capacity And Fixing To The Street Light Or Post Top Light Pole With Suitable Sizes Of Clamps, Nuts And Bolts Complete All As Specified And Directed By Engr-In-Charge. 27 S&F In Replacement Bracket For Street Light Fittings Made Out Of 40 Mm Dia Gi Pipe Of Medium Grade 1.5 Mtr Long Each Bent To Required Shape & Size And Fixed To Pole With And Including Flat Iron Clamps 02 Nos Made Out Of 32 X 6 Mm Flat Iron Including Gi Nuts, Bolts And Washers And Painting Of Clamps And Street Light Brackets With Two Coat Of Aluminium Paint Over A Coat Of Red Oxide Primer Complete All As Specified And Directed By Engr-In-Charge. 28 S&F In Replacement 150 Watt Led Flood Light With Pressure Die Cast Aluminium Housing & Toughened Glass With Ip-66 Degree Protection, Individual Leds Must Have Peanut Lenses For Better Throw Across & Along The Road With Luminarie Efficacy Of Greater Than 110 Lumen / Watt ( Minimum Lumen Output Of Luminarie Should Be 16500 Lumens ) Color Rendering ( Cri ) Of > 75 And Co-Related Color Temperature ( Cct ) Of 5700K ( + 500K ) , The Luminarie Should Have 5 Kv Surge Protection, Pf > 0.95, And Total Harmonic Distortion Of Thd < 10% ( Make Of Led Shall Be Cree / Nichia / Osram ) , Voltage Range Of 140-280V Should Be Provided. Luminarie Should Have Top Maintainable Driver Compartment For Easy Access To Driver During Maintenance. The Driver Used Must Be A Constant Current Driver With Efficiency Of > 85%. The Manufactures Logo Must Be Embossed / Engraved In The Housing Of The Luminarie. Manufactures To Provide Lm80 Test Report From Source Manufacturer And Should Have Adequate Testing Facilities Approved By Ministry Of Science ( Govt Of India ) To Provide Lm 79 Report Complete All As Specified And Directed By Engr-In-Charge. 29 S&F In Replacement 90 Watt Led Street Light With Pressure Die Cast Aluminium Housing & Toughened Glass With Ip-66 Degree Protection, Individual Leds Must Have Peanut Lenses For Better Throw Across & Along The Road With Luminarie Efficacy Of Greater Than 100 Lumen / Watt ( Minimum Lumen Output Of Luminarie Should Be 9000 Lumens ) Color Rendering ( Cri ) Of > 75 And Co-Related Color Temperature ( Cct ) Of 5700K ( + 500K ) , The Luminarie Should Have 5 Kv Surge Protection, Pf > 0.95, And Total Harmonic Distortion Of Thd < 10% ( Make Of Led Shall Be Cree / Nichia / Osram ) , Voltage Range Of 140-280V Should Be Provided. Luminarie Should Have Top Maintainable Driver Compartment For Easy Access To Driver During Maintenance. The Driver Used Must Be A Constant Current Driver With Efficiency Of > 85%. The Manufactures Logo Must Be Embossed / Engraved In The Housing Of The Luminarie. Manufactures To Provide Lm80 Test Report From Source Manufacturer And Should Have Adequate Testing Facilities Approved By Ministry Of Science ( Govt Of India ) To Provide Lm 79 Report Complete All As Specified And Directed By Engr-In-Charge. 30 S&F In Replacement 60 Watt Led Street Light With Pressure Die Cast Aluminium Housing & Toughened Glass With Ip-66 Degree Protection, Individual Leds Must Have Peanut Lenses For Better Throw Across & Along The Road With Luminarie Efficacy Of Greater Than 100 Lumen / Watt ( Minimum Lumen Output Of Luminarie Should Be 6000 Lumens ) Color Rendering ( Cri ) Of > 75 And Co-Related Color Temperature ( Cct ) Of 5700K ( + 500K ) , The Luminarie Should Have 5 Kv Surge Protection, Pf > 0.95, And Total Harmonic Distortion Of Thd < 10% ( Make Of Led Shall Be Cree / Nichia / Osram ) , Voltage Range Of 140-280V Should Be Provided. Luminarie Should Have Top Maintainable Driver Compartment For Easy Access To Driver During Maintenance. The Driver Used Must Be A Constant Current Driver With Efficiency Of > 85%. The Manufactures Logo Must Be Embossed / Engraved In The Housing Of The Luminarie. Manufactures To Provide Lm80 Test Report From Source Manufacturer And Should Have Adequate Testing Facilities Approved By Ministry Of Science ( Govt Of India ) To Provide Lm 79 Report Complete All As Specified And Directed By Engr-In-Charge. 31 Excavation In Trenches In Any Type Of Soil Not Exceeding 1.5 Meter Wide And Not Exceeding 1.5M In Depth For Laying Of Cables And Getting Out Of Excavated Material Complete All As Specified And Directed By Engr-In-Charge. 32 Description All As Per Serial Item No 31 Here-In-Before But Depth Exceeding 1.5 Meter And Not Exceeding 3 Meter Complete All As Specified And Directed By Engr-In-Charge. 33 Returning, Filling In, Including Spreading, Leveling, Watering And Well Ramming In Layers Not Exceeding 25Cm Thick Each, Excavated Soil In Trenches After The Cables Have Been Laid And Tested Complete All As Specified And Directed By Engr-In-Charge. 34 Removing Excavated Soil To A Distance Not Exceeding 50 Meter And Depositing Where Directed At A Level Not Exceeding 1.50 Meter Above The Starting Point Complete All As Specified And Directed By Engr-In-Charge. 35 M&L For Dry Sand Cushioning To Underground Cables Provided With A Layer Of Sand 8 Cm Thick Before Laying The Cable And 15 Cm Thick After Laying And Stretching The Cable, Sand Cushion Shall Be Punned To 18 Cm Thickness Complete All As Specified And Directed By Engr-In-Charge. Nnote: Only Punned Thickness Shall Be Measured And Paid. 36 Supply And Laying Burnt Brick Sub Class B For Cable Protection Laid Adjacent To Each Other Perpendicular To The Direction Of Cable In Trenches Complete All As Specified And Directed By Engr-In-Charge. 37 M&L For Cement Concreate 1:3:6 Type C-1 ( Using 20 Mm Graded Stone Aggregate ) As In Coping Etc Including Necessary Form Work Complete All As Specified And Directed By Engr-In-Charge. 38 M&L For Pcc 1:4:8 Type D-2 ( Using 40 Mm Graded Stone Aggregate ) In Foundation, Mass Concrate As In Foundation Of Pole & Stay Etc Complete All As Specified And Directed By Engr-In-Charge. 39 Taking Down The Unserviceable Lt Cable Of Any Size From Tranches / Walls / Floor Etc Complete All As Specified And Directed By Engr-In-Charge. 40 Supply, Laying, Jointing & Testing Xlpe Insulated, Pvc Bedded Galvanised Steel Strip Or Wire Armoured Electric Power Cable Heavy Duty With Stranded Aluminium Conductor 1100 Volts Grade Cross Sectional Area 10 Sqmm 2 Core Laid In Trenches Or Passing Through Pipe Or Fixed On Poles Complete All As Specified And Directed By Engr-In-Charge. 41 Description All As Per Serial Item No 40 Here-In-Before But Of Size 16 Sqmm 4 Core 42 Description All As Per Serial Item No 40 Here-In-Before But Of Size 25 Sqmm 4 Core. 43 Description All As Per Serial Item No 40 Here-In-Before But Of Size 35 Sqmm 3.5 Core. 44 Description All As Per Serial Item No 40 Here-In-Before But Of Size 50 Sqmm 3.5 Core. 45 Supply And Laying In Replacement Galvanised Iron Steel Tubes, Isi Marked Light Grade Of Size 40 Mm Bore For Cable Protection Along The Poles Under Road Under Drains, Laid In Trenches / Fixed On Walls / Poles With Suitable Clamps Bolts Nuts Etc Including Taking Down Of Old Unserviceble Pipe Complete All As Specified And Directed By Engr-In-Charge. 46 Supply And Laying In Replacement Galvanised Iron Steel Tubes, Isi Marked Light Grade Of Size 80 Mm Bore For Cable Protection Along The Poles Under Road Under Drains, Laid In Trenches / Fixed On Walls / Poles With Suitable Clamps Bolts Nuts Etc Including Taking Down Of Old Unserviceble Pipe Complete All As Specified And Directed By Engr-In-Charge. N 47 S&F In Replacement Aluminium Conductor Steel Reinforced ( Acsr ) Of Any Size On Poles, Stretched On Lt Poles Without Any Kink And Bends Of Various Sizes Complete Including Fixing To Insulator With Aluminium Binding Wire Complete All As Specified And Directed By Engr-In-Charge. 48 S&F In Replacement Ms Channel / Angle Iron / Flat Iron Of Required Size And Bend To Shape As Cross Arms, Bracing And Support Including, Ms Clamps, Back Plates With Bolts, Nuts, And Washers Drilled For Insulators Including Painting Two Coats Of Synthetic Enemel Paint ( Aluminium Shade ) Over A Coat Of Red Oxide Primer Complete All As Specified And Directed By Engr-In-Charge. 49 Cleaning The Existing Exposed Surfaces Of Steel Tubular Pole Of 9.0 Mtr Long Including Cross Arms, Brackets, Clamps Etc And Painting With Two Coats Of Synthetic Enamel Paint ( Aluminium Shade ) Marking Five Black & White Bands At Lower Portion Of Pole, Each 300 Mm Wide Alternately And Marking Pole No. With Yellow Paint On Black Base At Suitable Height Complete All As Specified And Directed By Engr-In-Charge. 50 S&F In Replacement Power Contactor 3 Phase 415 Volts, 40 Amps, Coil Voltage Of Rating 240 Volts Including Taking Down Old Unserviceable Power Contactor Complete All As Specified And Directed By Engr-In-Charge. 51 S&F In Replacement Power Contactor 4 Pole 240 Volts, 32 Amps, Coil Voltage Of Rating 240 Volts Including Taking Down Old Unserviceable Power Contactor Complete All As Specified And Directed By Engr-In-Charge. 52 Taking Down The Existing Led Street Light Fittings Of Any Type And Make Checking The Serviceability Complete All As Specified And Directed By Engr-In-Charge. 53 S&F In Replacement Driver For Led Energy Saving & Enviornment Area Light Fitting > 90 Watts Security Light With Active Power Factor Correction ( Apfc ) Electronic Driver. Led Driver 90 Watt With Operating Voltage Between 100-270 V Of Existing Specifications & Make Complete All As Specified And Directed By Engr-In-Charge. 54 S&F In Replacement Driver For Led Energy Saving & Enviornment Area Light Fitting > 48 Watts Security Light With Active Power Factor Correction ( Apfc ) Electronic Driver. Led Driver 48 Watt With Operating Voltage Between 100-270 V Of Existing Specifications & Make Complete All As Specified And Directed By Engr-In-Charge. 55 S&F In Replacement Automatic Street Light Switch Using Infrared Sensor Based Nature Switch For Automatic Switching Of Street Lights. Nature Switch Operation Should Be Based On Natural Light Lux* Level. Required Illuminance Level For Switching On Is = 30 Lux And For Switching Off = 10 Lux. The Sensor Should Also Have Part Night Operation Facility Of Min. 4 Hrs. To Max. 12 Hrs. The Sensor Along With Suitable Power Contactor, Incoming- Outgoing Mcbs And Auto-Manual ( Sensor By-Pass ) Selection Option Should Be Enclosed In A Pole / Wall Mountable Enclosure Made Of Rust Proof, Electric Shock Proof, Termite Proof And Fr Grade Smc Junction Box Conforming To Ip54. The Circuit Should Be Suitable Enough To Take Single-Phase Load Of 8Kw With Contactor & Incoming-Outgoing Mcb Rating Of 63 Amps & Circuit Wiring: Min. 16 Sq.Mm Complete All As Specified And Directed By Engr-In-Charge. Nmake: Kakatiya Energy Systems, Model No Swadeep-02Ec8kw1p Or Equivalent In Bajaj / Healer. 56 S&F In Replacement Automatic Street Light Switch Using Infrared Sensor Based Nature Switch For Automatic Switching Of Street Lights. Nature Switch Operation Should Be Based On Natural Light Lux* Level. Required Illuminance Level For Switching On Is = 30 Lux And For Switching Off = 10 Lux. The Sensor Should Also Have Part Night Operation Facility Of Min. 4 Hrs. To Max. 12 Hrs. Nthe Sensor Along With Suitable Power Contactors, Incoming- Outgoing Mcbs And Auto-Manual ( Sensor By-Pass ) Selection Option Should Be Enclosed In A Pole / Wall Mountable Enclosure Made Of Rust Proof, Electric Shock Proof, Termite Proof And Fr Grade Smc Junction Box Conforming To Ip54. Nthe Circuit Should Be Suitable Enough To Take 12Kw Load Equally Distributed Over 3-Phase With Contactors & Incoming-Outgoing Mcb Rating Of 40 Amps & Circuit Wiring: Min. 10 Sq.Mm Complete All As Specified And Directed By Engr-In-Charge. Nmake Of Nature Switch: Kakatiya Energy Systems, Model No Swadeep-02Ec12kw3p Or Equivalent In Bajaj / Healer. 57 M&L For Earthing Complete With Galvanized Steel Earth Plate Electrode 600 Mm X 600Mm X 6.0Mm Thick Buried Directly In Ground ( Earth Pit Not Less Than 2.25 Mtr Below Normal Ground Level ) With Top Edge Plate Not Less Than 1.5 Metre Below Normal Ground Level Connected To Galvanized Earth Wire Of Size 4 Mm Dia As Earthing Lead By Means Of Bolts, Nuts, Chuck Nuts And Washers Of Galvanized Iron Earth Lead Including Pcc Pit In Pcc 1:2:4 Type B-1, Rcc Cover Made Out Of Cement Concrete 1:2:4 Type B-1 ( Using 20 Mm Graded Crushed Stone Aggregate ) Reinforced With Tmt Steel Bars 8 Mm Dia @150 Mm C / C Both Ways With Suitable Handle And Angle Iron 40X40x5mm Frame, Gi Medium Grade Watering Pipe 20Mm Bore And Funnel With Wire Mesh Light Grade Protection Pipe 40Mm Bore Up To Main Board Complete As Shown On Electrical Plate No 3 Of Mes Sch 2009 ( Part-I ) And Testing On Completion Complete All As Specified And Directed By Engr-In-Charge. Nnote: On Testing After Completion Of Earthing, If Desired Earth Resistance Is Not Obtained, The Earthing Will Be Re-Done By The Contractor At His Own Risk & Cost To The Entire Satisfaction Of Engineer-In-Charge. 58 S&F In Replacement Switch Fuse Unit In Sheet Steel Enclosure Powder Coated, Weather Proof Confirming To Is 13947 ( Part 3 ) 1993 With Rewireable And Hrc Cum Rewireable Of Capacity 400 Amps Four Pole 415 Volts With Fuses Including Taking Down Old U / S Switch Fuse Unit All Complete All As Specified And Directed By Engr-In-Charge. Nmake: Haveels / Hpl / C&S
BRR : 1774202
Tender For Repair / Maintenance Of External Electrical Infrastructure And Connected Items In Domestic And Technical Area Including Lca Area-2 M&L for removing of 160 Watt flame proof lights along with hanging iron rods fixed in sun shelters by disconnecting the electric cable connections and re-fixing in same sunshelter but, other locations by necessary fixing arrangements like welding/clamp/nut bolt etc duly connecting with electric supply and testing complete all as specified and directed by the Engineer-In- Charge. (Total Sunshelters - 06 Nos) 3 Note for item No 2 :- The following items are deemed to be inclusive of quoted rate :- 4 (a)The above job shall be carried out by a trained electricians only 5 (b)The rate quoted for shifting of all lights in one Sun shelter shall be considered as on Job. Each sunshelters provided with 16 Nos flame proof lights 6 (c) Each sun shelters have approx. height of 10 meter and the ceiling of each sun shelters have provided with anti- bird net. For removal of lights, anti- bird net may be removed and kept without any damagefor re-fix after the fixing of lights. The contractor has to consider the above aspects while quoting the rate. The quoted rate shall deemed to be inclusive for removing and re-fixing of the anti- bird net if necessary and nothing extra shall be admissible on this account. 7 (d) Necessary T&P, Safety Belt, Vehicle, Aluminium Ladder, cranes etc. shall be arranged by the Contractor and Cost for the same shall deem to be included in the Quoted Unit Rate 8 (e)All safety measures and provn of all safety devices, first aid box etc shall be provided by the contractor.Contractor will be solely responsible forfull safetyof the persons deployed for providing the services and department will have no liability for any type of accident/injury of any type. Unit rate quoted will be deemed to include the cost of the same and no extra payment shall be made on this part. 9 (f)All type of T & P, PVC insulation tapes, minor nuts/ bolts/ washers etc required shall be provided by the contractor without any extra cost to department. 10 (g)Additional cables required if any shall be measured and paid seperately under relevent item here in after. 11 Supply onlyPVC insulated Copper Conductor Cable 1.5 Sqmm, single Core Round flame proof Flexible cable for connection of flame proof lights, complete all as specified and as directed. 12 M&L for periodical servicing / maintenance of 150 Watt High bay lights fixed in Hangars on quarterly basis including checking of loose connections tightening of loose nut bolts if any and cleaning and testing complete all as specified and directed by the Engineer-In- Charge.(Total Hangers - 05 Nos) 13 Note for item No 12 :- The following items are deemed to be inclusive of quoted rate :- 14 (a)The above job shall be carried out by a trained electricians only 15 (b)The rate quoted for servicing of all lights in one Hangers shall be considered as on Job. The payment shall be made on quarterly basisonly after testing of all lights in each sun shelter satisfactorily by the Engr-in-charge. 16 (c) Each sun hangers have approx. height of 12 meter and the ceiling of each hangers have provided with anti- bird net. For the servicing of the lights, the anti- bird net may be removed and kept without any damagefor re-fix after the fixing of lights. The contractor has to consider the above aspects while quoting the rate. The quoted rate shall deemed to be inclusive for removing and re-fixing of the anti- bird net if necessary and nothing extra shall be admissible on this account. 17 (d) Necessary T&P, Safety Belt, Vehicle, Aluminium Ladder, cranes etc. shall be arranged by the Contractor and Cost for the same shall deem to be included in the Quoted Unit Rate 18 (e)All safety measures and provn of all safety devices, first aid box etc shall be provided by the contractor.Contractor will be solely responsible forfull safetyof the persons deployed for providing the services and department will have no liability for any type of accident/injury of any type. Unit rate quoted will be deemed to include the cost of the same and no extra payment shall be made on this part. 19 (f)All type of T & P, PVC insulation tapes, minor nuts/ bolts/ washers and cables etc required for maintaining the services shall be provided by the contractor without any extra cost to department. 20 M & L for disconnecting of burnt/ damaged cables from panels/ junction boxes etc, cutting out the burnt out ends, making new end joints by supply and fixing new aluminium lugs/ insulation tapes etc and reconnecting using new nuts/ bolts/ washer etc and restoring three phase and neutral in the junction box complete all as directed for the 25/ 35 sqmm 3.5 core size of LT underground armoured cablescomplete all as specified and directed. 21 Note for item No 20 :- Earth work required for extending the incoming/ outgoing cable in junction box/ panel board etc shall be deemed to be included in the unit rate quoted. 22 S & F GI tubing 40/50 mm bore light grade 1.2 mtr long bent to shape as required with clamps for fixing of street light on poles/ walls including nuts, bolts, washers clamps of suitable size including taking down existing onecomplete all as specified and directed. 23 S & F Singlepole MCB 6 to 32 Amps, 240 v, 50 Hz ACsuitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996including taking down existing one complete all as specified and directed. 24 Supply and fixing in repairs LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. 25 Supply and fixing in repairsTPN, MCB 40 to 63 amp, 240 v, 50 Hz ACsuitable for ‘C’ curve, 10 KA breaking capacitycomplete conforming to IS 8828 of 1996 completeall as specified and directed 26 Excavation in trenches in hard/dense soil not exceeding 1.5m wide and not exceeding 1.5 metre in depth for laying of cable and not exceeding 10 Sqm on plan for poles, struts, stays etc. and not exceeding 1.5 m in depth and getting out completeall as specified and directed 27 Riddling Sand obtained from excavation for cable protection 8cm under the cable and 15cm above the cable in trench and get the thick layer of 18cm after ramming complete all as per specified and as directed. . 28 Note for item No 27 :- In case sufficient sand not obtained from excavation, the rate is deemed to be inclusive for additional qty of sand requiredto be obtain from outside MD land as directed by the Engineer-in-Charge 29 Removing excavated materials not exceeding 50m distance and depositing where directed at level not exceeding 1.5 m above the starting point complete all as per specified and as directed. 30 S&F Fly ash bricks using modular bricks as in cable protection cover including taking down existing bricks of any size complete all as per specified and as directed. 31 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soil complete all as specified and directed. 32 S&F XLPEinsulated, screened, PVC Bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with aluminium conductor 1100Volts grade cross sectional area 25 Sqmm 3.5 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, taking down existing cable etc complete all as specified and directed. 33 Note for item No 32 :- Excavation and earth work shall be measured and paid separately. 34 S & F Cable jointing kit for 1.1 KV grade cable for outdoor straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 10 sqmm to 16 sqmm complete all as specified and directed. 35 M & L for cutting existing road/PCC/Drain for laying of DI/GI or any type of pipe including necessary earthwork, excavation exc 600mm depth but not exc 1mtr depth, wide 800mm including making existing surface with PCC 1:2:4 type B1 using 20mm aggregate thickness of concrete is 150mmcomplete all as specified and directed. 36 Note for item No 35 :-The tenderer shall take into consideration for following points while quoting his rate for this item andthe unite rate is deemed be included for :- 37 (i) Earth work excavation in any type of soil 38 (ii) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick complete all as specified and as directed. 39 (iii) Removing excavated material to out side MD land 40 (iv)Laying of any type/any bore of pipe in trenches including taking down any description. Supply of pipe will be measured and paid separately 41 (v)150 mm thickPCC 1:2:4 type B1 as inany type of road 42 (vi) GI pipe requiredfor cable protection shall be measured and paid separately under respective item. But labour required for take the cable through GI pipe and laying in trench shall deemed to beincluded in the rate quoted. 43 Supply only GI pipe 50 mm bore medium grade for cable protection completeall as specified and as directed by Engr-in-Charge. 44 M & L for disconnecting of burnt/ damaged cables from panels/ junction boxes etc, cutting out the burnt out ends, making new end joints by supply and fixing new aluminium lugs/ insulation tapes etc and reconnecting using new nuts/ bolts/ washer etc and restoring three phase and neutral in the junction box complete all as directed for the 10/16 sqmm 4 core size of LT underground armoured cablescomplete all as specified and directed.. 45 Note for item No 44 :- Earth work required for extending the incoming/ outgoing cable in junction box/ panel board etc shall be deemed to be included in the unit rate quoted. 46 M & L for cleaning vegetation around the LT pole completely root out from soil and clean the surface onemtr around the pole of street lights complete all as specified and as directed. 47 Note for item No 46 :- Removing of accumulated earth depth upto 15cm cleaning / Cutting the grass with hand operated petrol/ kerosene driven grass cutting machine andremoving thegrass waste to outside MD land is deemed to be included in quoted rate. 48 S&F Powercontactors 40 Amps, 4 pole,415V, including taking down old item complete all as specified and as directed. Make : Cat No 412553 of Legrand or equivalent of L&T/ Siemans 49 M & L for preparing surfaces by removing exisiting faded sky blue and white straps on PCC poles and applying a coat of sky blue/white straps painting with synthentic enamel paint, eachsky blue/white straps of 30 cm height up to 1.5 mtr from top of PCC coating, writing pole no with white paint on black base of PCC pole by sentensile measure includingapplaying one coat of synthetic enamel paint to clamps/cross arm/street light GI bracket fixed on pole complete all as specified and as directed 50 Supply & fix in repair PVC insulated Copper Conductor Cable 1.5 Sqmm, 3 Core Round Flexible for connection of Street Light Fitting, complete all as specified and as directed. 51 M&L Sub main wiring for circuit complete with 2 runs of 1.5 sqmm single core PVC insulated, unsheathed FRLS1100 Volt grade multi stranded copper conductor cable drawn through and incl suitable size non-metallic PVC Conduit and accessories complete fixed surface to wall/roof/ceiling etc and 1 run of 1.5 sqmm single core PVC insulated, unsheathed FRLS 1100v grade multi stranded copper conductor cable as earth continuity conductoretc including taking down existing sub main wiring complete all as specified and directed. 52 Note for item No 51 :- (a) Two runs of 1.5 sqmmpower cable , one run of 1.5 sqmm earth conductor and one run of PVC conduit/casing capping will be measured as one length. 53 (b)Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. 54 M & L for removing steel swagedtubular pole 8.5/9 mtr long for providing suitable new bracket for fixingstreet lightand re-fixing the poleincluding necessary PCC 1:4:8, type D2 (using 40 mm graded stone aggregate) for foundation of 50 x 50 x 45 cm and coping with 1:2:4, type B1 (using 20 mm graded stone aggregate) complete all as specifiedand directed by Engr-in-chrage 55 S&F in repairs Connector suitable for fixing of Cable of size Cross sectional area 10 Sqmm to 25 Sqmm armoured/PVC for preventing of Short Circuiting of Cable in Junction Boxes, complete all as specified and as directed. 56 M & L for preparing the existing painted steel surface and painting with one coat of aluminium paint on cross arms, clamps, MS flat and street light brackets if any on Steel / RCC pole for Doublecross Arm for three Phase4 wire system complete all as specified and directed. 57 Supply and fixing in repairs LED flood light 210 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.. 58 S&F XLPEinsulated, screened, PVC Bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with aluminium conductor 1100Volts grade cross sectional area 16 Sqmm 4 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, taking down existing cable etc all as specified and directed. 59 Note for item No 58 :- Excavation and earth work shall be measured and paid separately. 60 Supply, transporting to site, erecting and fixing in position, steel tubular swaged poles of 9mtr longtype 410 SP- 31 IS-2713 marked complete with CI/ MS base plate, finial taper plug, bolts, nuts, washers and screws as specified, drilling of necessary holes including painting with two coats of aluminium paint overa coat of red oxide primer on exposed surface and black bituminous paint on steel surface embedded in concrete externally and throughout internally and painting 03 nos of band /strips with fluorescent , PO box red synthetic enamel paint (30 cm wide each) at a distance of 30 cm from plinth block and number of poles including taking down existing one completeall as specified & directed by Engineer-in-Charge. 61 Note for item No 60 :- Earth work excavation, PCC foundation, coping will be measured and paid separately. The rate for pole shall also be included painting to steel tubular pole (in side and out side). 62 M&L cement concrete 1:4:8,type D2 (using 40mm graded stone aggregate ) including necessary form work for pole foundation complete all as specified and directed by Engr-in-Charge . 63 M&L cement concrete 1:3:6 type C2(using 40mm graded stone aggregate) including necessary form work for pole foundation complete all as specified and directed by Engr-in-Charge . 64 M&L PCC 1:2:4 type B-1 using 20mm graded stone aggregates as in pole coping completeall as specified & directed 65 S&F Powercontactors 63 Amps, 4 pole,415V, including taking down old item complete all as specified and as directed. Make : Cat No 412557 of Legrand or equivalent in PS 66 M & L for preparing the painted steel surfaces of existing LT steel tubular pole including cross arms, clamps MS flats, steel light bracket if any etc and applying one coat of aluminium paint(above ground/coping level) not exc 8 mtr long including painting of strips of height 0.3mtr each (three nos sky blue and three nos white), writing pole no with black paint with letters/figures 7.5 cm high and tightening of cross arms, clamps and street light brackets complete all as specified and directed. 67 S&F LED aviation obstruction light with IP 66 protection water clear poly carbonate UV stabilized dome neoprene rubber with bind spike with 302 Nos LED bulbs including necessary electric connections including 2.5 sqmm, 2 core, PVC copper cables fixed on wall with 20mm dia PVC conduit from DB to light fitting fixed in and including GI pipe 25mm dia 1 mtr long grouted with PCC complete/ binding with existing angle frame etc complete including taking down existing one complete all as specified and directed.Make : Bajaj Cat No - 110731 or equivalent in Wipro/ CG. 68 M & L earthing testing, identifying the earth and recording of test results in prescribed format all as directed by Engineer-in-Charge. Each earth pit result be submitted to Engineer-in-Charge duly signed by user and MES rep for earth test less than 1 Ohm (10 pits and more considered 1 earthing point) 69 Earthing testing, identifying the earth and recording of test results in prescribed format all as directed by Engineer-in-Charge. Each earth pit result be submitted to Engineer-in-Charge duly signed by user and MES rep for earth test less than 3 Ohm (4 pitsand more considered 1 earthing point) 70 Earthing testing, identifying the earth and recording of test results in prescribed format all as directed by Engineer-in-Charge. Each earth pit result be submitted to Engineer-in-Charge duly signed by user and MES rep for earth test less than 4 Ohm (3 pits and more considered 1 earthing point) 71 Earthing testing, identifying the earth and recording of test results in prescribed format all as directed by Engineer-in-Charge. Each earth pit result be submitted to Engineer-in-Charge duly signed by user and MES rep for Conventional type earthing (individual pit) 72 Note for item No 68 to 71 : The following items are deemed to be inclusive of quoted rate :-(i)The above job shall be carried out by a trained technician having ITI in electrical and well known regarding earthing test. Documentary proof of the education of tradesman shall be produced, before commencement of work. 73 (ii) The afore said test will be carried out in presence of user and MES representative.(iii) Two Party (consisting 2 x 1 No. Technician with 2 x 1 No. Helper) will report every Morningat 9 AM to JE E/M for Daily earth testing. 74 (iv) They will testEarth Resistance Every Day ( not more than 10 Nos earthing/day) in presence of user & MES rep and willrecord it in prescribed format , same will be put to Engineer-in-Charge,JE E/M duly signed by user & MES rep on very Next Day, failing which a Sum of Rs. 100.00 per Day will be recovered from the Contractor. 75 (v) Earth Resistance Tester will be provided by the Contractor. (Tester should be calibrated from Authorised Company/ Lab). 76 (vi) Contractor will be responsible for pouring of water in the Earth Pits Weekly at their own arrangement with Water Tanker, etc. (water will be provided by the contractor at his own arrangement and nothing extra will be admissible). 77 (vii) Checking of Earth Pits existing and improve it by watering / adding a layer of Salt/ Magnesium Sulphate/ Charcoal, etc. 78 (viii) Contractor will be responsible for marking of Earth check date and due date on existing Plate with paint as specified by Engineer-in-Charge. 79 (ix)Contractor will be responsible for cleaning of bushes and grass all around upto 1.50 Metre Area of existing Earth Pit with tightening of Strip. 80 (x)EP No should be mentioned on individual earth pits and ER value of installation etc all as specified and directed by Engr In Charge. 81 (xi)It will be the responsibility of the contractor to liase with Station authority to obtain security pass as per station rules for entering/ working in high security tech area. 82 Checking of any breaking in the link of earth strip wire of Galvanised/Copper/Aluminium Strip any size and jointing them by Exothermic Welding or Brazing including taking down old unserviceable one, complete all as specified and as directed. 83 Attending unserviceable/ non-functional street light complaints (for street light/perimeter lights/high mast light/flood light etc of any type/size fitted on poles/walls/post/pillars etc)by deploying technically qualified and experienced technicians to find out defective/taking out unserviceable parts such as electronic driver, PVC insulated copper conductor cable for connecting street light fittings etc and repairing by changing the defective parts including minor repair to cable connection/loose connection, screws, nuts & bolts and insulation tap to insulate the LT joint etc and testing complete all as specified and as directed for domestic area of old Kalpa colony, new Kalpa colony, Mehra colony, MAP qrts, Akash enclave, Gulmohar enclave, Kiran enclave, MES colony, AFWWA, various connecting roads and other facilities such as shopping complex/ various institutes/ messes/ play ground, complete perimeter etc located in complete domestic area andtechnical area at AF Station Sulur 84 Note for item No 83 :- The following items are deemed to be inclusive of quoted rate :- 85 (a)The above job shall be carried out by a trained electrician having ITI in electrical, documentary proof of the education of tradesman shall be produced before commencement of work. 86 (b)Supply only items to be delivered/ supplied to AGE E/M store yard as per qty asked by Engineer-in-Charge with in one calendar month from the date of commencement of contract and these items will be issued from AGE E/M store yard for attending unserviceable/ defective street light complaints. 87 (c)Contractor or his Authorised Representative has to inspect all Street/ Security Lights on Daily basis at their own arrangement between 7.00 PM to 9.00 PM and maintain the record in Register which will be put up to Engineer-in-Charge/ JE on the very Next day. 88 (d) A Joint Inspection for Serviceability of all Street/Security Lights will be carried out from 7.00 PM to 9.00 PM on every MONDAY by Engineer-in-Charge/ JE (E/M)/ User along with Contractor or his authorised Representative. 89 (e) Contractor has to arrange own moveable Generatorof suitable capacity for repairing and testing of the Street/ Security Lights, defect rectification of Cables, etc. and to check the serviceability after repair.No Electricity shall be provided by the Department on this account. 90 (f) Quoted Unit Rate shall deemed to be inclusive of attending any breakdown of Street/ Security Lights during night. Contractor has to arrange Electrician and Helper and all necessary T&P and Equipments to remove the breakdown. Fault will be intimated through Telephone/ SMS. 91 (g)In case of any delay in attending the complaint more than 12 hrs after handing over routine/urgent work, the contractor shall be liable to pay the penalty as described in penalty clause given here as under. 92 (h) The penalty shall be applicable to the contractor if the delay is noticed by the Engr-in-Charge more than twelve hrs after handing over works of urgent nature to the contractor. The Engr-in-Chargeshall handover the slip containing specification of work to the contractor by lodging the time and signature of contractor be obtained on slip.The contractor shall attend the complaint immediately and shall report to Engr-in-Charge with in 12 hrs. The contractor will keep his tradesmen in stand by for attending any routine / urgent works from the executive.If the nature of job is such that the work cannot be completed within period of 12hrs then the facts shall be brought to the notice of the GE/Engr-in-Chargeand the period for the working to the complaint shall be decided by the GE/EIC. If the delay is more then twelve hrs period and the GE is not satisfied with the reason for delay then penalty at the rate of Rs 50/- per job shall be deducted from the dues of the contractor. Please note that this penalty is exclusively other then the condition 56 of IAFW - 2249 and shall be treated as interim condition of the contract and shall be enforce above as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Dept.The decision of the Accepting Officer is this regards shall be final and binding. 93 (j) Contractor has to ensure serviceability of all Street/ Security Lights of DOMESTIC & TECHNICAL AREA on Daily basis in any Weather Condition at their own arrangement. 94 (k)Contractor shall provide conveyance to the deployed labour for maintaining the services without any extra cost to department. 95 (l)Vehicle mounted ladder for maintaining services shall be provided by the contractor at no extra cost to department. 96 (m) Materials requiredfor the repairing of the lights shall be measured and paid separately under respective item(s). But labour required for taking down, dismantling, repairing and replacing parts and reinstalling and testing the street lights fittings shall deemed to beincluded in the rate quoted. 97 (n)Necessary T&P, Safety Belt, Vehicle, Aluminium Ladder, etc. will be arranged by the Contractor and Cost for the same shall deem to be included in the Quoted Unit Rate. 98 (o)All safety measures and provision of all safety devices, first aid box etc shall be provided by the contractor.Contractor will be solely responsible forfull safetyof the persons deployed for providing the services and department will have no liability for any type of accident/injury of any type. Unit rate quoted will be deemed to include the cost of the same and no extra payment shall be made on this part. 99 (p)All type of T & P, PVC insulation tapes, minor nuts/ bolts/ washers etc required for maintaining the services shall be provided by the contractor without any extra cost to department. 100 (q)Attending and repairing complaint for onelightof any type shall be measured and paid as one Job. 101 (r)Earth work (if necessary at Site) for removing of any Cable Fault will be Measured and Paid under respective Items. 102 (s) The contractor shall maintain a record of all urgent work at and if the work is repeated due to poor workmanship, he will be liable to repair the same without any extra expenditure to the Govt. 103 (t)Contractor shall provide contact details of his responsible person(s) for any emergency. 104 (u) Any Materials replaced which are not specified in SCHEDULE OF CREDIT will be deposited to MES STORE YARD without any extra Cost to the Department. 105 Supply only electronic Driver with input voltage 220 to 240Volt and output voltage suitable for LED light fitting of capacity 10 watt, complete all as specified and as directed. 106 Supply only electronic Driver with input voltage 220 to 240Volt and output voltage suitable for LED light fitting of capacity 20 watt, complete all as specified and as directed. 107 Supply only electronic Driver with input voltage 220 to 240Volt and output voltage suitable for LED light fitting of capacity 36 watt, complete all as specified and as directed. 108 Supply only electronic Driver with input voltage 220 to 240Volt and output voltage suitable for LED light fitting of capacity 45 watt, complete all as specified and as directed. 109 Supply only electronic Driver with input voltage 220 to 240Volt and output voltage suitable for LED light fitting of capacity 76 watt, complete all as specified and as directed. 110 Supply only electronic Driver with input voltage 220 to 240Volt and output voltage suitable for LED light fitting of capacity 120 watt, complete all as specified and as directed. 111 Supply only electronic Driver with input voltage 220 to 240Volt and output voltage suitable for LED light fitting of capacity 160 watt, complete all as specified and as directed. 112 S & F GI water tubes of size of 20 mm bore medium grade ISI markedwith all fittings such as bend, elbow, socket, tee etc and fixed completeto wall and ceilings or laid in floors including taking down old unserviceable one, complete all as specified and as directed. 113 S & F Bib taps 20 mm bore, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete including taking down old unserviceable one, all as specified and as directed. 114 S & F in repairs Air Termination Single Pointed Aluminium Rod dia upto 20mm and length upto 300mm including provision of Cement Concrete 1:2:4 (20mm graded stone aggregate) Block 300x300x300 mm and necessary Fixing Arrangement at Roof, complete all as specified and as directed. 115 Note for Item No 114:- If threaded of the Rod is damaged then Contractor will be responsible for cutting of thread for fixing the Rod. Any minor repairs/ materials is deemed to be included. 116 S & F Aluminium strip 25 x 3mm with saddles and fixing screws etc. for roof conductors and down conductors above ground including taking down existing one complete all as specified and directed. 117 S & F Galvanised Iron Tubing/Pipe 40mm bore, light grade for Strip Protection, fixed in Walls/Floors with suitable type of Clamps, etc. including taking down old unserviceable one, complete all as specified and as directed. 118 S & F in repairs Stainless steel screw/ nut and bolts (machine made) with hexagonal or square heads at one end and screwed the other each screwed end to be fitted with washers and one hexagonal or square nut of dia 5mm to 10mm, n. exc 25mm long complete all as specified and directed. 119 S & F Mild Steel Sheet of size approximate 300x200x1.6mm thick Sheet Egg type, Half round type, Rectangular type and Triangular type with welded 1 (Inch) dia 2 (Feet) long Mild Steel Pipe with duly different Synthetic Enamel Paint cutting of Equipment Earth/ Lighting Arrester Earth/ Signal Earth etc. complete as specified duly painted as specified and marking of Earth Plate Number/ Description of Earthing/Type of Earthing on Plate with White Paint including Earth Plate No. and Earthing Resistance with Earthing Check Date and Earthing Check Due Date including taking down old unserviceable one, complete all as specified and as directed 120 Excavation in existing defective earth pit as notified by the Engr-in-Charge and spreading Common Salt, Charcoal dust and Magnesium sulphate complete all as specified and directed by Engr-in-Charge. 121 Note for Item No 120:-Common Salt, Charcoal dust and Magnesium sulphate shall be measured in relevant item of schedule. However labour element for spreading is deemed to be included. 122 Supply only common salt commercial in trenches to improve the ER value of existing earth pits complete all as specified and directed. 123 Supply only charcoal dust/Breeze each bags of 25 Kg in trenches to improve the ER value of existing earth pits complete all as specified and directed. 124 Note for Item No 123:-Earthing charcoal dust/Breeze shall be supplied in packing as per originally packed by the manufacture 125 Supply only Magnesium sulphate in trenches to improve the ER value of existing erath pits complete all as specified and directed.. 126 S&F XLPEinsulated, screened, PVC Bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with aluminium conductor 1100Volts grade cross sectional area 10 Sqmm 4 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, taking down existing cable etc all as specified and directed. 127 Note for item No 126 :- Excavation and earth work shall be measured and paid separately. 128 Supply and fixin replacement of high power LED street light fittings energy saving luminaire with lens , capacity 36 watt with system efficacy (lm/w) shall be 100 lumenper watt or more lumens per watt, total system lumen not less than 3600 lumens, PF not less than 0.95, CRI not less than 70,colour temp. 5000K to 6500 K, surge protection not less than 5 KV, high pressure die cast aluminium alloy LM6 housingIP-65/66 class 1 protection, toughened glass cover, driver efficiency > 85% with constant output of current and voltage against input voltage variation 120 to 270 volt at 50 Hz ( + 5%), THD< 10% completeincluding taking down existing complete all as specified and directed. 129 S&F XLPEinsulated, screened, PVC Bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with aluminium conductor 1100Volts grade cross sectional area 10 Sqmm 2 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, taking down existing cable etc complete all as specified and directed. 130 S&F XLPEinsulated, screened, PVC Bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with aluminium conductor 1100Volts grade cross sectional area 6 Sqmm 2 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, taking down existing cable etc complete all as specified and directed. 131 Note for item No 129 & 130 :- Excavation and earth work shall be measured and paid separately. 132 Supply and fixin replacement of high power LED street light fittings energy saving luminaire with lens , capacity 60 watt with system efficacy (lm/w) shall be 100 lumenper watt or more lumens per watt, total system lumen not less than 3600 lumens, PF not less than 0.95, CRI not less than 70,colour temp. 5000K to 6500 K, surge protection not less than 5 KV, high pressure die cast aluminium alloy LM6 housingIP-65/66 class 1 protection, toughened glass cover, driver efficiency > 85% with constant output of current and voltage against input voltage variation 120 to 270 volt at 50 Hz ( + 5%), THD< 10% completeincluding taking down existing complete all as specified and directed. 133 S & F synchronising electronic timer unit operated on AC 230 Volts, 24 hrs clock time for controlling street lights including taking down old unserviceable timer switches complete all as specified and directed.Make :-Cat Part No : 4126 41 of Legrand or equivalent in L&T, ABB. 134 M & L cleaning of existing solar street light panels fixed above street light pole of approximate height 6 meter by using wet cloth dipped in soap water including the panel perimeter complete all as specified and directed. 135 Note for Item No 134:- (i) The contractor shall be responsible for arrange necessary conveyance vehicle, Aluminium self supporting ladder/bamboo ladder, bucket, soap powder, cloths etc and the quoted rate shall be deemed to be inclusive for the above. 136 (ij) Contractor has to ensure serviceability of solar street light panel of DOMESTIC & TECHNICAL AREA on Daily basis in any Weather Condition at their own arrangement. 137 (iii)Contractor shall provide conveyance to the deployed labour for maintaining the services without any extra cost to department. 138 (iv)Vehicle mounted ladder for maintaining services shall be provided by the contractor at no extra cost to department. 139 (v)Necessary T&P, Safety Belt, Vehicle, Aluminium Ladder, etc. will be arranged by the Contractor and Cost for the same shall deem to be included in the Quoted Unit Rate. 140 (vi)All safety measures and provision of all safety devices, first aid box etc shall be provided by the contractor.Contractor will be solely responsible forfull safetyof the persons deployed for providing the services and department will have no liability for any type of accident/injury of any type. Unit rate quoted will be deemed to include the cost of the same and no extra payment shall be made on this part. 141 M&L in repairs Earthing with Galvanised Earth Plate Electrode 600x600x 6mm thick burried directlyin Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with Galvanised Earth Strip of size 25x6mm by means of Bolts, Nuts, Check Nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar including GI 40mm bore (dia) light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt Magnesium Sulphate (1 : 1: 0.5) in alternate layers of not exc 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50 mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) medium grade including necessary Excavation in Soft/Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion, complete all as per specified and as directed. 142 Note for Item No 141 :-(a)All Joints should be joined by Exothermic Welding or Brazing. 143 (b)After completion of work earthing shall be tested by the contractor in presence of Engineer-in-Charge, User and proper record shall be maintained duly signed by all concerned. 144 (c)Earth resistance tester will be provided by the contractor. It should be calibrated from authorised company/ lab.. 145 (d)After testing if desired earth resistance of less than 3 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained. 146 (e)Rate shall include GI strip and protection pipe of length up to 7.5m 147 S&F Galvanised earth strip of size 25 x 6mm fixed on proper post insulator at the instrument end including taking down existing strip complete all as specified and directed. 148 Taking down existing GI strip 25x3mm thick as earthling lead with its accessories and re-fixing to wall/roofs etc. drawn in conduit/GI pipe etc complete all as specified and as directed 149 Note for Item No 148:-Unit rate is deemed to be included for old broken insulators/ clamps replace with new insulators of existing size from site and making good disturbed surfaces of floors/walls/ceiling etc complete all as directed. 150 S & F Epoxy base insulators of suitable size 40mm height for fixing GI earth strip on wall/ceiling/floor/poles etc including taking down existing one complete all as specified and as directed 151 Note for Item No 150:-Quoted Unit Rate deem to be included drilling holes per Metre or as specified on GI/Aluminium/Copper Strip of any type and size. 152 M & L for cutting and screwing existing GI tubing of size 20 /25/ 40mm bore for alterations or additions complete all as specified and as directed 153 Supply only chemical i.e. ground enhancing compound in bag of 25 Kg each complete all as specified and directed. 154 Note for Item No 153:-Material shall be delivered in the store yard of AGE E/M or as directed by AGE E/M and nothing extra shall be payable on this account. 155 S & F Stop valve, cast copper alloy, screwed down, high pressure with crunch or butterfly handle screwed both ends for union and fixed for size 20mmborepipe complete including taking down existing one complete all as specified and directed. 156 Repairing Damaged Earth Pit Cover Factory Made Earth Chamber in cement concrete 1:3:6(20mm stone aggregate) as shown in Electrical Plate No. 03 of MES Schedule Part- I and providing Pre-cast RCC 1:2:4 (20mm graded stone aggregate) in Slab /PitCover 450x450x 50mm in size, reinforced with and including 10mm dia TMT Bars @ 100mm Centre to Centre in both ways including Funnel and cleaning the surrounding of Earth Pit Cover and pouring Salt Water to improve the resistance and measuring and recording the same in presence of Engineer-in-Charge, complete all as specified and as directed. 157 S & F Copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc including taking down existing one complete all as specified and directed. 158 Note for Item No 157:-All Joints should be joined by Exothermic Welding or Brazing. 159 M & L for Brazing / exothermic welding arrangement for existing copper strip of size 32 x 6 mm / 20 x 3 mm thick completeall as specified and directed. 160 S & F Test Point Terminal Block made of Gun Metal or Phosphorus Bronze size 75x75x25mm, drilled and screwed including 3 No. 8mm dia, 25mm long hexagonal Head Screw including taking down old unserviceable one, complete all as per specified and as directed. 161 S & F Air Termination Single Pointed Copper Rod 16mm dia and 300mm long with arrester clamp 16mm made out of Brass including provision of cement concrete 1:2:4 (20mm graded stone aggregate) block 300 x 300x 300mm and necessary fixing arrangement at roof including taking down old unserviceable one, complete all as specified and as directed. 162 Note for Item No 161:-If threaded of the Rod is damaged then Contractor will be responsible for cutting of thread for fixing the Rod. Any minor repairs/ materials is deemed to be included. 163 S & F Factory Made RCC 1:2:4 (20mm graded stone aggregate) in Slab/Pit Cover 350x350x50mm in size, reinforced with and including 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, complete including taking down existing one all as specified and as directed. 164 Removing existing unserviceable earthing system and Supply, installation, testing & commissioning of maintenance free chemicalearthing system comprising 17mm dia copper bondedrod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducingliquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 A by any NABL accredited lab. The above mentioned rod shall be installed in 8-10 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation. 165 The quoted rate shall also deemed to be included the following :- (i)Prior toinstallation of maintenance free chemicalearthing, soil resistivity test to be carried out at the location where earthingwork to be donein presence of Engr-in- Charge/JE (E/M),user and the report has tosubmitto Garrison Engineer with recommendation of manufacturer, if required additional interconnection ofearthing (not more than 04 number of earthing) to achieve earth result less then 1 Ohms. The arrangement done for soil resistivity testingandsubmission of report with recommendationdeemed to be included in the quoted rate. 166 (ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors. 167 (iii) Rateofearth energizer compound of 25 Kg of 02 bags and earthresistance reducingliquid 10 litre per cane for each pit deemed to be included in the quoted rate. 168 (iv)Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor before commencement of work. 169 (v) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH valve should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete. 170 (vi) Copper strip of size 20 x 3 mm shouldbe fixed on proper post insulator at the instrument end ( The rate of earthing strip up to7.5 Mtrs is included in the quoted rate). 171 (vii)Testing of earth shall be carriedout in presence ofdepartmental and user representativeand report shall be submitted to Garrison Engineer duly signed by all concern. 172 (viii)Earth resistance tester will be provided by the contractor.Tester should be calibrated from authorised company/ lab. 173 (ix)Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintained duly signed by all concerned.After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained. 174 (x) The contractor shall given a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion. 175 (xi) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including dry or rocky soil. 176 (xii) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is maintained. 177 (xiii) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing per each earthing shall be retained from payment due to the contractor for the guarantee period. 178 (xiv) The electrode shallcarry manufacturers name . 179 (xv) The connection clamp shall be permanently welded to the copper bounded rod to avoid any kind of connectivity loss. The pre-welded copper bounded rod shall not need any additional clamp for termination. 180 (xvi) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm. 181 (xvii)The contractor shall submit CPRI India certified document for copper bonded rod to ensure genuinity of material. 182 (xviii) Sign boardof mild steel 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxideZinc chrome primer showing result of earthing should be fixed near the earth pit after completion as directed by engr -in- charge. 183 (xix)Earth work such as auguring andmaking good the surrounding area shall carried out in any type of soil. 184 S & F in repairs Earth pit cover madeof heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 9.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mm dia for each electrode pit complete all as specified and directed. 185 Note for Item No 184 :- The contractor shall submit load bearing capacity certificate from the manufacturer. 186 Supply and fix IP 66 Thermoplastic PC- GFS Polycarbonate weather-proof Junction Box size 255L x 205B x 112D MM with plain walls for cable entries to be drilled individually, system voltage : 415V, 50hz,The plain side walls on the four sides can be drilled and customized for cable entries from any direction. Lid fasteners shall not have screws but shall be with quarter turn locking knobs – which is well visible ( open – locked), and they will be sealable without any accessories.Cable terminal :- 25 Sq mm- 4 no with 10A SP MCB- 1 no, 6sq mm disconnected terminal- 1 no, The junction box shall fulfil the following standards Weather proof : UV resistant due to solar radiation, Rainwater proof, temperature resistant. Salt water proof & shall be suitable for off-shore applications. IEC 60670-22 : Particular requirements for connecting boxes and enclosures. IEC 60695 – 2 – 11 : Flame – retardant & Self-extinguishing. Glow Wire tested at minimum 960 deg C. IEC 60529 : IP 66 / IP 67 / IP 69 degree of protectionincluding taking down existing all as specified and directed. 187 Taking down carefully hanger lights for repair/ replacement of defective spare parts such as ballast, etc including taking down old one of any capacity from 150 watts Flame Proof light including cleaning internally and externally fixing back the fitting in same position after repair and test complete all as specified and as directed. 188 Note for Item No 187:-Following shall be part of job under this item :- 189 (a)The above job shall be carried out by a trained electrician 190 (b)All sort of petty T&P items such as PVC insulation table, ladder, galvanised screws, nuts, bolts, washers etc. required to accomplish the job shall be provided by the contractor with out any extra cost to dept. 191 (c) Necessary T&P, Safety Belt, Vehicle, Aluminium Ladder, cranes etc. shall be arranged by the Contractor and Cost for the same shall deem to be included in the Quoted Unit Rate 192 (d)All safety measures and provn of all safety devices, first aid box etc shall be provided by the contractor.Contractor will be solely responsible forfull safetyof the persons deployed for providing the services and department will have no liability for any type of accident/injury of any type. Unit rate quoted will be deemed to include the cost of the same and no extra payment shall be made on this part. 193 Supply and fix in repairs flame proof electronic LED driver suitable for flame proof flood light fitting 150W sun shelter down light/ flood light fitting of make Sudhir/Baliga/ CG complete all as specified and directed. 194 M&L for Sub main wiring with PVC insulated unsheathedFRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 sqmm drawn through in and including suitable size steel conduit and all accessories fixed to wall/floors along with 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size complete all as specified and directed. 195 Note for item No 194 :- (a)2 runs of 4 sqmm cable along with onerun of 4 sqmm cable for earth conductor and one run ofsteel conduit shall be measured as one length. 196 (b)Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. 197 M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 sqmm drawn through in and including suitable sizesteel conduit and all accessories fixed to wall/floors along with 6 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size complete all as specified and directed. 198 Note for item No 197 :- (a)2 runs of 6 sqmm cable along with onerun of 6 sqmm cable for earth conductor and one run of steel conduit shall be measured as one length. 199 (b)Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. 200 S&F Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed. 201 Supply and fixing in replacement of switch flame proof switch socket and plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P + earth, complete all as specified and directed Make : Sudhir, Bajaj, Baliga. 202 Supply and fixing in replacement of LUMINAIRE WELLGLASS LED ZONE I-Gr IIC LM6 Die cast Aluminium LM6 housing, 230V AC, 50 Hz Suitable for 150W LED fitting with 2 Nos of 0.75ET cable Entry, Neoprene gasket , Stainless steel Hardware, Epoxy powder coating light grey finish shed 631/IS-5 with cable gland, plug & lamp complete all as specified and directed. Make cat No FLPW-2595/II C/L of Sudhir, Bajaj or Baliga or equivalent make 203 S&F in replacement of flame proof bulk head fitting 5 W (to be used with Red LED Bulb) including fixing arrangement all as specified and directed. 204 S&F in replacement of cable tray perforated type of size 100 x50mm made out of 1.6mm thick GI sheet fixed in PEB structure by providing MS angle 40x40x5mm clamps etc including fittings like bend, tee and making good the disturbed portion and matching with existing surface complete all as specified and directed 205 S&F in replacement of flame proof weather proof VTPN distribution board 4 way 415 volts with MCCB 63A , FP, 16 KA as incommer-01 No and MCB 32A TP-02 Nos MCB 16A SP-18 Nos as out going complete all as specified and directed.. Make-Sudhir or Bajaj, Baliga or equivalent make.
BRR : 3721802
Tender For Repair Maintenance Of Street Light Security Light Including Allied Work Under Allenby Ph Area Under Ge Utility Ambala Cantt; 1 Supply & Fixingin Replacement Of Integral Led Flood Light Luminaries 100 Watts Consisting Of Suitable Number Of Leds Andmounted On Mcpcb High Pressure Die Cast Aluminium Housing With Sealed Toughened Glass Cover With Secondary Optics Lens, Ip 66 Protection Suitable For Mast Light Mounting, 5700K, Led Efficiency >130 Lm / Watt And System Efficiency 110 Lm / W , 240 Volts Ac, 50 Hz, Cri>70% Operating Voltage Range 160 V-270 V, Power Factor> 0.95, Working Temperature Range -10ºc To 50ºc, Built In Surge Protection Of More Than 10 Kv , Confirm The Tests From Auth Labs :Lm79 & Lm 80, Incl Proper Fixing And Testing Of Flood Lights On 9 / 11 Mtr Long Steel Tubular Pole And Provide Facility Of Power Supply Shall Be Provide As Suitable For Maint Work Of Light Fittings Incl Make Proper Connection Of New And Existing Light Fittings Complete With Cutting , Welding , Drilling Holes, Nut Bolts, Washer Complete All As Specified & Directed. 2 All As Per Item Sr No 1 Here But For 150 Watts Led Luminaires Complete All As Specified & Directed 3 All As Per Item Sr No 1 Here But For 200 Watts Led Luminaires Complete All As Specified & Directed 4 Supply & Fixingin Replacement Ofled Street Light Fitting45 Watts Made Up Of Pressure Die Cast Aluminium Housing With High Efficiency Leds As Lighting Source And Lens Embedded Toughened Glass Having Top Opening Seperate Driver Compartment With Ip 66 Protection And Impact Resistance Of Ik07 Consisting Of Suitable Number Of Leds With Sealed Toughened Glass Cover, 5700K, Led Efficiency >110 Lm / Watt And System Efficiency 110 Lm / W , 240 Volts Ac, 50 Hz, Cri>70% Operating Voltage Range 140 V-270 V, Power Factor> 0.95, Mains Current 0.270A, Working Temperature Range-10ºc To 50ºc, Built In Surge Protection Of More Than 10 Kv, Better Optics For Uniform Distrubution With Multiple Leds Not Less Than 2 Watt Each And Having Optical Grade Polycarbonate Lens With All Accessories , Suitable For Side Entry, Pole Mounting With Bracket Arm Od 40 Mm, Recommended Mounting Height With Suitable Inground Reinforcement Is 8 Mtrs, Confirm The Safety Test As Per Is 15885 Part-2 From Auth Labs :Lm79 & Lm 80, Incl Proper Fixing And Testing Of Street Lights On 9 / 11 Mtr Long Steel Tubular Poleincl Make Proper Connection Of New And Existing Light Fittings Complete With Cutting , Welding , Drilling Holes, Nut Bolts, Washer Complete All As Specified And Directed. Note :-Pvc Heavy Duty Conduit Pipe Along With 3 / 1 Run Of 1.5 / 2.5 Sqmm Pvc Insulated Unsheathed / Sheathed Copper Multistranded Conductor From Mcb Box To Streetshall Be Measured And Paidfor Separately. 5 All As Per Item Sr No 4 Here But For 70 Watts Led Luminaires Complete All As Specified And Directed. 6 All As Per Item Sr No 4 Here But For 90 Watts Led Luminaires Complete All As Specified And Directed. 7 Dismantling And Taking Down Security Light, Street Light, Hanger Light, Flood Light And High Mast Lights Of Any Type At Any Height Fittings Such Ashpsv / Hpmv / Mh / Led Light Of 48 Watt / 60 Watt / 70 / 72 Watt / 90 Watt / 120 Watt / 150 Watt / 200 Watt And 300 Watt Of Any Make Etc. Ac 230 Volts Any Wattage From Pole / Wall Roof Top / Hanger Roof Including Washing / Cleaning Of Perplex Cover Inspection For Location Of Faultand Replacing Of Defective Spare / Parts Required For Smooth Functioning, Tightening Of Electric Connection, Assembling And Reconnecting All As Per Site Requirment Complete All As Specified And Directed. Note: Defective Spare / Part Of Relevant Light Fitting Shall Be Measured And Paid Separately Under Relevant Item As Supply Only. 8 Supply Only Led Electronic Driver / Adaptor / Spdfor40-48 Watt Ledsecurity Light Fitting Of As Per Existing Makecomplete All As Specified & Directed. 9 Supply Only Led Electronic Driver / Adaptor / Spdfor60 Watt Ledsecurity Light Fitting As Per Existing Make Complete All As Specified & Directed. 10 Supply Only Led Electronic Driver / Adaptor / Spdfor70 / 72 Watt Ledsecurity Light Fitting As Per Existing Makecomplete All As Specified & Directed. 11 Supply Only Led Electronic Driver / Adaptor / Spdfor90 Watt Ledsecurity Light Fitting As Per Existing Makecomplete All As Specified & Directed. 12 Supply Only Led Electronic Driver / Adaptor / Spdfor 100 / 120 Watt Led Flood Light Fitting As Per Existing Makecomplete All As Specified & Directed. 13 Supply Only Led Electronic Driver / Adaptor / Spdfor150 Watt Ledflood Light Fitting As Per Existing Make Complete All As Specified & Directed. 14 Supply Only Led Electronic Driver / Adaptor / Spdfor200-300 Watt Ledflood Light Fitting As Per Existing Makecomplete All As Specified & Directed. 15 Labour Only For Trimming Of Tree Branches Oh Lines Of Ht / Lt & Maintain Approaching Minimum Clearance Of 3 Mtrfrom Branches. Proper Shutdown Will Be Taken And Maintained In The Register Complete All As Specified And Directed. 16 Supply & Fixing In Replacementof Automatic Street Light Control Switch With Infrared Sensor Based Nature Switch & Voltage Monitoring System ( Vms ) . Three Phase, 25 Amps Per Phase, Mcb Rating 32 Amp, Max Load 8-12 Kw Incl Circuit Copper Wire 10 Sq.Mm.Nature Switch Operation Should Be Based On Natural Light Lux Level. Required Illuminance Level For Switching On Is = 60 Lux And For Switching Off = 10 Lux. The Sensor Should Also Have Part Night Operation Facility Of Min. 4 To Max. 12 Hrs. Vms Should Have Adjustable Over & Under Voltage Trip Level And Protection Against Phase Loss, Neutral Loss & Phase Reverse. The Sensor & Vms Along With Suitable Power Contactor ( S ) And Incoming-Outgoing Mcbs Should Be Enclosed In A Pole / Wall Mountable Enclosure Made Of Rust Proof, Electric Shock Proof, Termite Proof And Fr Grade Smc Junction Box Conforming To Ip54. The Circuit Should Also Have Provision For Manual Operation ( I.E. By-Pass Option For Both Sensor ( Ns-02 ) And Vms ) . Madel :Swadeep-02Ec-8Kw3p-Vms Complete All As Specified And Directed.Note ( I ) S S Nut Bolts, Clamp For Fixing On Poles / Wall Are To Be Included In Quoted Rates. ( Ii ) The Sensor Must Have The Warranty Of Min Of 2 Years. ( Iii ) The Test Certificate And Warranty Certificate Must Be Provided By Supplier. ( Iv ) Cost Of Marking Description On The Box Is Included In Quoted Rate. 17 Supply & Fixing In Replacementof Automatic Street Light Control Switch With Infrared Sensor Based Nature Switch & Voltage Monitoring System ( Vms ) . Single Phase, 25 Amps Per Phase, Mcb Rating 40 Amp, Max Load 5-8 Kw Incl Circuit Copper Wire 10 Sq.Mm.Nature Switch Operation Should Be Based On Natural Light Lux Level. Required Illuminance Level For Switching On Is = 60 Lux And For Switching Off = 10 Lux. The Sensor Should Also Have Part Night Operation Facility Of Min. 4 To Max. 12 Hrs. Vms Should Have Adjustable Over & Under Voltage Trip Level And Protection Against Phase Loss, Neutral Loss & Phase Reverse. The Sensor & Vms Along With Suitable Power Contactor ( S ) And Incoming-Outgoing Mcbs Should Be Enclosed In A Pole / Wall Mountable Enclosure Made Of Rust Proof, Electric Shock Proof, Termite Proof And Fr Grade Smc Junction Box Conforming To Ip54. The Circuit Should Also Have Provision For Manual Operation ( I.E. By-Pass Option For Both Sensor ( Ns-02 ) And Vms ) . Madel : Swadeep-02Ec-5Kw1p-Vms Complete All As Specified And Directed.Note ( I ) Nut Bolts, Clamp For Fixing On Poles / Wall Are To Be Included In Quoted Rates. ( Ii ) The Sensor Must Have The Warranty Of Min Of 2 Years. ( Iii ) The Test Certificate And Warranty Certificate Must Be Provided By Supplier. ( Iv ) Cost Of Marking Description On The Box Is Included In Quoted Rate. 18 Excavation In Trenches Not Exceeding 1.5 Metre Wide And Not Exceeding 1.5 Metre In Depth For Foundation, Shafts, Man Holes, For Under Ground Cable / Erection Of Poles, Stays, Locatingfault Of Lt Cable And Stay Assembly Etc Not Exceeding 10 Square Metre On Plan And Getting Out In Any Type Of Soil Including Dressing / Trimming Of Sides And Leveling, Grading And Ramming Of Bottom Of Excavation Complete All As Specified And As Directed. 19 All As Per Ser Item No 18.00 Here In Before But Depth Exceeding 1.5 Metre And Not Exceeding 3.0 Metre Complete All As Specified & Directed. 20 Returning, Filling In, Soil, Including Spreading, Levelling, Watering And Well Ramming In Layers Not Exceeding 25Cm Thick Each Layer Complete All As Specified And Directed. 21 Removing Excavated Material / Soil To A Distance Not Exceeding 50M And Depositing Where Directed At A Level Not Exceeding 1.5M Above The Starting Point Complete All As Specified And Directed. 22 Material And Labour For Sand Cushioning To Cable With A Layer Of Sand 8 Cm Thick Before Laying The Cable And 15 Cms Thick After Laying The Cable ( Punned Down To 18 Cms Depth After Laying And Stretching Of Cable ) Complete All As Specified And As Directed. 23 Supply And Lay Bricks, Common Burnt Clay, Sub Class B, Old Size, Laid In Vertical Direction To Cable As Cable Protection Complete All As Specified And As Directed. 24 All As Per Ser Item No 23.00 Here In Before But Except Bricks, All As Specified And Directed.Note:- Old Bricks Retrieved From Ser Item No 28.00 To 35.00 Here In After Shall Be Re-Used. 25 Material & Labour For Cement Concrete In Foundations, Filling And Mass Concrete Pcc As Foundation To Poles, Type D2, 1:4:8 Using 40 Mm Graded Stone Agregate As Foundations To Poles Complete All As Specified And Directed. 26 Material & Labour For Cement Concrete, Filling And Mass Concrete, Pcc Type C2, 1:3:6 Using 20 Mm Graded Aggregate Complete All As Specified & Directed. 27 Material & Labour For Cement Concrete As Coping To Poles, Pcc Type B1, 1:2:4 Using 20 Mm Graded Stone Agregate As Foundations To Poles A Complete All As Specified & Directed. 28 Disconnecting & Taking Out Defective Underground Cable From Trenches, Pole, Pipe, Floor, Wall Etc And Locate The Fault, Rectify The Defect And Relaying The Xlpe Cable Underground Pvc Insulated And Overall Sheathed Aluminum Conductor Heavy Duty 1100 Volts Including Connecting And Testing For Any Size Complete All As Specified & Directed. ( Excavation / Earth Work & Sand Cushioning, Bricksandjoint Shall Be Measured & Paid For Separately ) . 29 Supply, Laying, Connecting And Testing Xlpe Underground Cable Insulated, And Overall Sheathed With Aluminium Conductor Heavy Duty 1100 Volts Grade10 Sqmm 4.0 Core Including Aluminium Thimbles Laid In Trenches / On Pole / Road Crossing Or Passing Through Existing / New Pipe Under Road Crossing Clamping On Wall Etc Including Taking Out Existing U / Scable Complete All As Specified & Directed.Note : ( I ) Earth Work, Sand, Bricks Removing, Returning Filling Will Be Paid Seperately. ( Ii ) Cost Of Laying Electrical Cable Through New / Existing Pipe Under Road, Buildings, Railway Tracks, Highways Are Incl In The Quoted Rates ( Iii ) All Equiments, Machinery Or Tool If Required For Laying Electrical Cable Through New / Existing Pipes Are Provided By The Contractor Without Any Extra Cost. 30 All As Per Item Ser No 29 Here In Before But For 4 Core 16 Sqmm Complete All As Specified & Directed. 31 All As Per Item Ser No 29 Here In Before But For 3.5 Core 25 Sqmm Complete All As Specified & Directed. 32 All As Per Item Ser No 29 Here In Before But For 3.5 Core 35 Sqmm Complete All As Specified & Directed. 33 All As Per Item Ser No 29 Here In Before But For 3.5 Core 50 Sqmm Complete All As Specified & Directed. 34 All As Per Item Ser No 29 Here In Before But For 3.5 Core 70 Sqmm Complete All As Specified & Directed. 35 All As Per Item Ser No 29 Here In Before But For 3.5 Core 95 Sqmm Complete All As Specified & Directed. 36 Supply And Fixing In Replacement Of Fabrication Of Kiosk Box Made Out Of Fibre Material Complete With Tpn , Aluminium Bus And Suitable For One Number Mcb ( Sp ) Including One No Mcb ( Sp ) 6 Amps 240 Volts With Glands For Incoming & Out Going Cable Including Fixing Of Flat Iron Clamps Of Size 20X4mm On Pcc / Steel Tubular Polecomplete All As Specified & Directed.. Make: Havells / Sintex. 37 Supply And Fix In Replacement Of Mcb Sp 6-32 Amps, 240 Volt, 10 Ka B Curveincluding All Accessories Complete All As Specified And Directed. 38 Supply And Fix In Replacement Of Mcb Dp 16-40 Amps, 240 Volt, 10 Ka B Curveincluding All Accessories Complete All As Specified And Directed. 39 Supply And Fix In Replacement Of Mcb Tpn 32-63 Amps, 240 Volt, 10 Ka B Curveincluding All Accessories Complete All As Specified And Directed. 40 Supplying And Fixing In Replacement Of 1100 Volts Grade Heavy Duty Cable Pvc Insulated Aluminium Conductor, Served With Inner Sheathing Of Pvc Tape And Overall Pvc Sheathed In Service Connections Suspended By Insulating Hangers Not More Than 1 Metre Apart Including 4Mm Suspension Wire, One Twin Core Cable Flat Or Circular Of Size 10 Sqmm 2 Core Complete All As Specified And Directed. 41 Supply And Fixing In Replacement Or Passing Through Pvc Conduit Pipe Of 1100 Volts Grade Heavy Duty, Pvc Insulated Round 3 Core 1.0 Sqmm Copper Cable Including Electrical Connection Suitable Size Of Lugs, Nuts And Bolts Complete All As Specified And Directed. 42 Supply And Fixing In Replacement Or Passing Through Pvc Conduit Pipe Of 1100 Volts Grade Heavy Duty, Pvc Insulated Round 3 Core 2.5 Sqmm Copper Cable Including Electrical Connection Suitable Size Of Lugs, Nuts And Bolts Complete All As Specified And Directed. 43 Supply And Fixing In Replacement Or Passing Through Pvc Conduit Pipe Of Single Core Pvc Unsheathed Multi Stranded Copper Cable ( Frls ) 1.5 Sqmm Nominal Cross Sectional Area 1100 Volts Conforming To Is 694 Including Electrical Connection Suitable Size Of Lugs, Nuts And Bolts Complete All As Specified And Directed. 44 Supply And Fixing In Replacement Or Passing Through Pvc Conduit Pipe Of Single Core Pvc Unsheathed Multi Stranded Copper Cable ( Frls ) 2.5 Sqmm Nominal Cross Sectional Area 1100 Volts Conforming To Is 694 Including Electrical Connection Suitable Size Of Lugs, Nuts And Boltscomplete All As Specified And Directed. 45 Supply And Fixing In Replacement Of Rigid Non-Metallic Pvc Conduit Of Dia 20 Mm Exclusive Of Boxes ( Junction / Terminal ) But Inclusive Of All Tees, Bends, Elbows, Reducers, Bell Mouth Tube Ends And Fixing Accessories Such As Couplers, Lock Nuts, Saddles, Pipe Hooks Etc Complete All As Specified & Directed.Note: Pvc Pipe Will Be Clamped At Three Position On Pole And Cost Of Clamp, Nut, Bolts Etc Are Incl In Quoted Rates Complete All As Specified And Directed. 46 Supplying And Fixing In Replacement Oflight Gradegalvanised Mild Steel Pipe 80Mm Bore With All Fittings, Laid Under Roads, Drain, Paths, Fixed To Poles / Walls With Suitablemild Steel Clamps, Bolts, Nuts And Washerscomplete All As Specified & Directed.. Note:- Excavation & Earth Work Shall Be Measured And Paidfor Separately Under Appropriate Item Of This Schedule. 47 All As Per Item No 46 Here-In-Before But Of Size 40 Mm Bore Complete All As Specified & Directed. 48 Supply & Fixingin Replacement Of Bracket Made Out Of Gi Tubing Single Piece Not Welded, Bended At Proper Angle Of Size 40Mm Dia, Light Grade 1.5 Mtr Long Including Painting With Aluminium Paint Over One Coat Of Red Oxide Primer To The Bracket Complete All As Specified And As Directed. 49 Supply & Fixing In Replacement Of Ms Clamp Suitable For Holding Street Light Bracket On Steel / Pcc Polemade Out Of 40 Mm X6 Mm Thick Flat Iron With M.S Nuts Bolts 50 Mm Long 10 Mm Dia-3 Nos With Flat Washer 3Mm Thick -02 No For Each Includingpainting With Aluminium Paint Over One Coat Of Red Oxide Primer To The M.S Clamps Complete All As Specified & Directed. 50 Supply, Fix And Erection Of Prestressed Concrete Pole 9.0 Mtr Long In True Vertical Position 102X172 Mm At Top 102X279 Mm At Bottom Class-10 Incl Providing Black And White Strips With Synthetic Enamel Paint 30 Cm Each Alternate Upto 1.5 Mtr Including 2 Bands Of Radium Tape Of 2 Width Greeen & Red Colour Above The Coping Of Pole Starting With Black Strip Including Dismantalling And Taking Down Old Unsv Pole Complete All As Specified & Directed.. Note ( I ) Earth Work And Pcc Shall Be Measured And Paid Seperately ( Ii ) Description As Per Direction Of Engineer-In-Charge Will Be Printed On Each Pole Without Any Extra Cost. 51 Supply, Fix Anderection Of Steel Tubular Swaged Poles Complete With Cast Iron Base Plate, Finial Taper Plug, Bolts, Nuts And Screws As Specified Type 410 Sp-31, 09 Meter Long, Providing Synthetic Enamel Aluminium Paint Over One Coat Of Red Oxide And Black And White Strips With Synthetic Enamel Paint 30 Cm Each Alternatively Upto 1.5 Mtr Including 2 Bands Of Radium Tape Of 2 Width Greeen & Red Colour Above The Coping Of Pole Starting With Black Strip, Including Dismantalling And Taking Down Old Unsv Pole Complete All As Specified & Directed.. Note ( I ) Earth Work And Pcc Shall Be Measured And Paid Seperately ( Ii ) Description As Per Direction Of Engineer-In-Charge Will Be Printed On Each Pole Without Any Extra Cost. 52 Supply And Fix Inreplacementof Lithium Based Energy Efficient Integrated Solar Street Light Of 32 Watt” In Single Frp Body With Duly Polyurethane Coating ( Camouflage Color ) , Encases With Monocrystalline Solar Pv Panel Of 64 / 66Wp , Lithium Battery 11.1 / 12.8V, 33.0Ah With Inbuilt Bms, Ip 65, High Brightness W-Led ( 160-180Lm / Watt ) Lamp With Aluminum Reflector For Better Light Distribution , Cri >70, Color Temperature 5700°K - 6500°K, Microcontroller Based Charge Controller Cum Driver, Automatic Dimming Function ( First Four Hours At Full Brightness & Rest Of The Time At Lower Light Level With Pir Motion Sensor ) , Dusk To Dawn Operation, Suitable To Working Temperature: ( - ) 10°C To ( + ) 55°C, Weight Not More Than 16-18Kg With Adjustable Ms Clamp Suitable For Pole / Wall Mounting Etc Complete As Required. Protections: Short Circuit, Overload, Reverse Polarity And Battery Protections. Firm Should Provide Vital Parameters Test Report From Nabl Accredited Lab And Should Be Of Made In India With Ce & Rohs Compliant Including Tubular Pole 6 Mtr Height With Bottom Base Plate 200X200x12 Mm , Outdoor Dia Not Less Than 65 Mm With Heavy Duty Gi Pipe Or Steel Thickness 3Mm And Suitable Arrangement To Mount Solar Light As Directed On Pole Including Foundation Pcc 1:3:6 Type C-1Using 20Mm Graded Crushed Stone Aggregate And Erection As Per Manufacturer Drawing, Providing Synthetic Enamel Aluminium Paint Over One Coat Of Red Oxide Primer Complete All As Specified And Directed Make:- Axxon ( Axn-32W ) Or Equivalent Of Phillips / Bajaj / Wipro / Havells 53 Dismantling And Taking Down Old Unsv Lt Feeder Pillar And Supply, Installing, Testing & Commissioning In Replacement Of Outdoor Type Cubical Lt Feeder Pillar Panel Box Size 1.0Mx0.8Mx50cm With Double Door Type Cubical Panel Board Outer Shell Made Out Of3.15 Mm Thick Crca Sheet And Inner Shell Made Out Of 2 Mm Thick Crca Sheet And Ms Angle Section 50X50x6 Mm Mounted On Pcc 1:2:4 Type B-1 Platform 60 Cm Aboveand 45 Cm Below The Ground Level, Frame Factory Fabricated With Front And Rear Openable Double Door System And Cable Alley ( Each Door Hinged With Body At 3 Places With Body And Hinges Should Be Welded With Body And Door ) Lockable / Openable By Keyshaving Chromium Plated 19 Mm Dia Fancy Lock, “U” Type Gasket Shall Be Used To Make The Outer Shell Completely Vermin Proof Suitable For 3 Phase 4 Wire 415 Volt, 50 Hz, Incl Aluminium Bus Bar Of 200 A , Tested At Factory Approved From Cpri Factory Fabricatedhaving Modern Fabrication And Testing Process Followed By Powder Coat Painting Having Thickness Not Less Than 100 Microns Provided With Suitable Gasket To Make It Dust / Vermin Proof And General Construction Confirming To Is:61439 / 2011Part-1 Andpart -2 Type Test Certificate With Not Less Thanip-56And Breaking Capacity 65 Ka Comprising Of The Following :-A ) Incoming Mccb100 Amps, 16 Ka 4 Pole 415 Volts Ac, -01 No. ( B ) Outgoing Mccb63 Amp, 10 Ka, 4 Pole 415 Volt Ac, -02 Nos. ( C ) Outgoing Mcb32 Amp, 10 Ka , Tpn 415 Voltac -02 Nos ( D ) Ryb Indication Led Type, 22.5 Mm Dia, Protected With Mcb Sp 2 Amp Showing 3 Phase Supply -03 Nos ( E ) Digital Ammeter Of Range 0-200 A, Auxiliary Voltage 230 Volts With Selector Switch -01 Nos ( F ) Volt Meter Of Range 0-500 Volts, Auxiliary Voltage 230 Volts With Selector Switch -1 No ( G ) Misc Items Like Screws, Cable Tie, Copper Cable 1.5 / 2.5 Sqmm, Cabe Lugs, Sleeves, Glands Etc Complete Are Included In Quoted Rates. 54 Dismantling And Taking Down Old Unsv Lt Feeder Pillar And Supply And Installing, Testing & Commissioningin Replacement Of Factory Fabricated Outdoor Type Feeder Pillar Board Of Size 1.0Mx0.8Mx0.50 Mtr , Outer Shell Made Out Of3.15 Mm Thick Crca Sheet And Inner Shell Made Out Of 2 Mm Thick Crca Sheet And Ms Angle Section 50X50x6 Mm Mounted On Pcc 1:2:4 Type B-1 Platform 60 Cm Aboveand 45 Cm Below The Ground Level, Frame Factory Fabricated With Front Openable Double Door System And Cable Alley ( Each Door Hinged With Body At 3 Places With Body And Hinges Should Be Welded With Body And Door ) Lockable / Open Ablewith Arrangement Of Pad Locking On Door01 No Of Pad Lock Of Three Keys Shall Be Used To Make The Outer Shell Completely Vermin Proof Suitable For 3 Phase 4 Wire 415 Volt, 50 Hz, Tested At Factory Approved From Cpri Factory Fabricatedhaving Modern Fabrication And Testing Process Followed By Powder Coated Painting After 7-Tank Pre Treatement Control & Power Wiring With Suitable Size Of Copper Conductor Along With Suitable Gasket To Make It Dust / Vermin Proof And General Construction Confirming To Is:61439 / 2011Part-1 Andpart -2 Type Test Certificate With Not Less Thanip-56And Breaking Capacity 65 Ka Comprising Of The Following :- ( A ) Mccb 160 Amps Tpn, 25 Ka -01 No ( B ) Mccb 40Amp Tpn 4 Pole - 04 Nos ( C ) Aluminium Busbar Of Capacity 200 Amps With Colour Coated Heat Shrinkable Sleeve And Suitable Hole For Out Going Connection - Set Of Four. ( D ) Misc Items Like Screws, Cable Tie, Copper Cable 1.5 / 2.5 Sqmm, Cabe Lugs, Sleeves, Glands Etc Complete Are Included In Quoted Rates 55 Notes For Item Sr No.53 To 54 ( I ) The Quoted Rate Shall Include Minor Items Such As Lugs, Nuts & Bolts, Washers, Top Insulators, Sleeves, Provision Of Extra Holes In Bus Bar Etc. ( Ii ) All Internal Wiring Shall Be Done With Suitable Size Of Pvc Insulated Solid Copper Conductor Frls Cable Conforming Tois-694. ( Iii ) Panel Drawing Shall Be Got Approved Before Placing Of Orderfrom Engr-In-Charge / Ge. ( Iv ) The Bus Connection For Cable From Main Bus Bar To Outgoing Mccb Will Be Connected Through Suitable Rating Bus Bar Strip Type Duly Insulated. ( V ) Cable Will Be Entered In Panles Through Gland. ( Vi ) Cost Of Marking Description And Matter On The Front Door As Specified And Directed By Engr-In-Charge Is Incl In Quoted Rate. 56 Material And Labour In Replacement Of Broken Earth Pit Of Size 300X300x300 Mm Madeof Pcc 1:2:4 Type B1 Using 20 Mm Graded Crushed Stone Aggregate, And Earth Pit Cover Made Out Of Rcc 1:2:4 Type B1, Cover Reinforced With 8 Mm Dia Tmt Bars @ 100 Mm Centre To Centre Both Ways With Handle Made Out Of 8 Mm Dia Bar, Watering Arrangement With Funnel And Wire Mesh And Including Reconnecting Of Earth Lead Of Any Type With New Nuts, Bolts And Washers As Required At Site With Testing Result Complete All As Specified & Directed.. 57 Material And Labour In Replacement Of Stay By Tightening Of Stay Wire After Untying The Conductor Spans From The Poles To Make Correct Tensions And Maintain Verticality Of Poles, Including Re-Jointing The Conductors In Position With New Binding Wire Complete All As Specified & Directed.. 58 Repairing Of Existing Unserviceable Pcc Coping Of Lt / Ht Pole By Breaking Completely And Material And Labour For Pcc 1:2:4 Type B1, ( Using 20Mm Graded Crushed Stone Aggregate ) Of Size 600X600x300mm Including Form Work And Applying Two Coats Of White Wash Complete All As Specified & Directed.. 59 Dismantling Andtaking Down Old U / S Earthing Andmaterial And Labour For Earthing Complete With Galvanized Steel Plate Earth Electrode 60Cmx60cmx6mm Thick Surrounded By Char Coal And Salt Buried Directly In Ground Vertically In Pit Of Depth Not Less Then 2.25 Mtr Below Ground Level With Top Edge Of The Earth Plate At Depth Of Not Less Than 1.5 Mtr Below Ground Level Surrounded From All Sides By Char Coal Dust And Common Salt In Alternate Layers Of 15 Cm Depth And Earth Plate Electrode Connected To Galvanised Earth Lead Wire Of 4.0 Mm Dia By Means Of Gi Nuts Bolts, Check Nuts And Washers And Connected To Earthing Test Point Drawn Through 15 Mm Bore Gi Pipe Medium Grade For Protection Of Gi Earth Lead Wire Including 20Mm Bore Gi Pipe Medium Grade For Watering Gi Funnel Pcc Earth Pit ( 1:3:6 ) Type C-2 With Ci Frame And Rcc Cover All As Shown In Electrical Plate No 3 On Ssr Part - I Including Testing Complete All As Specified And As Directed.Note : ( I ) The Quoted Rate Shall Include The Cost Of Earth Work, Gi Pipe For Watering, Gi Protection Pipe, Funnel, Wire Mesh, Rcc Cover, Etc. Complete. Rcc Cover Shall Be 50Mm Thick In 1:2:4 Type B-1 Using 8Mm Bars @10Cm C / C Both Way. ( Ii ) The Quoted Rate Shall Include The Cost Of The Earth Pit Covers To Be Conspicuously Marked Of Plate With Standgrouted In Pcc. ( Iii ) On Testing After Completion If The Desired Earth Resistance Ismore Than 2? The Earthing Will Be Redone At No Extra Cost 60 Supply And Fixing In Replacement Mccb Tpn 315 / 320 Amps, 415 Volts, 36 Ka, 4 Pole , Ics=100% Icu, Overload Adjustable Short Circuit Adjustable Type Incl Spreader Link And Complete Connection Complete All As Specified & Directed.. 61 Supply And Fixing In Replacement Mccb Tpn 200 Amps, 415 Volts, 25 Ka, 4 Pole , Ics=100% Icu, Overload Adjustable Short Circuit Adjustable Type Incl Spreader Link And Complete Connection All As Specified And Directed. 62 Supply And Fixing In Replacement Mccb Tpn 160 Amps, 415 Volts, 25 Ka, 4 Pole , Ics=100% Icu, Incl Spreader Link And Complete Connection All Asspecified And Directed. 63 Supply And Fixing In Replacement Mccb Tpn 630 Amps, 415 Volts, 36 Ka, 4 Pole , Ics=100% Icu, Incl Spreader Link And Complete Connection All As Specified And Directed. 64 Material And Labour For Detecting Of Fault In Cable Ht / Lt With Fault Locator Equipment Supplying Of Ht / Lt Electric Supply ( 11 Kv / 430 Volts ) To Make The Ht / Lt Cableserviceablewith Straight Throughjoint Of Size 70-300 Sqmm.Notes: ( A ) The Ht Fault Which Is Detected Through Cable Fault Locator Will Only Be Paid Under This Item. ( B ) Transportation Charges Of Cable Fault Locator And Dg Set Deemed To Be Included In The Quoted Rate. ( C ) Earth Fault Locator Will Be Provided By The Contractor For Even Single Ht Fault And No Delay On This Account Will Be Acceptable Otherwise Penalty Will Levied Rs 500.00 Per Hour. ( D ) Straight Through Joint , 95 To 300, Sqm, Labour Charges, Excavation And Making Joint Deemed To Be Including In Quoted Rate. 65 Supply And Fixing In Replacement Lt Line Separators 1100 V Grade Pvc Spacer To Separate Lt Conductor From Each Other 5 Line As Per Is Complete All As Specified & Directed. 66 Supply And Fixing In Replacementlt Line Separators 1100 V Grade Pvc Spacer To Separate Lt Conductor From Each Other 4 Line As Per Is Complete All As Specified & Directed. 67 Supply And Fix In Replacement Of Air Circuit Breaker, Fixed Type, Spring Operated, Manually Tpn, 4 Pole, 800 Amp, 415 Volts With Thermal Magnetic Release, ( O / L, S / C, E / F Protection & Confirming To Iec-60947-2& 3 Rated Breaking Capacity And Making Capacity 50 Ka Short Time Current Complete All As Specified & Directed. 68 Supply And Fix In Replacement Of Danger Notice Plate Of 1.6Mm Thick Mild Steel Sheet, Vitreous Enamelled Red, With Letters, Figures And Conventional Skull And Bones In Signal White Colour And Fixed With M.S. Clamps, Bolts And Nuts Of Approved Size, For Lt, 20X15cm Size Complete All As Specified And Directed 69 Material & Labour Chemical Spray ( Dc 2.26 Contact Cleaner ) In Container Of 415 Ml / 300G For Precision Blended Multipurpose Product For Prevents Corrosion Penetrates, Lubricants, Displaces And Seals Out Moisture Release Rusted Mechanisum Cleanese Etc Complete All As Specified & Directed.. 70 Material And Labour Inreplacementofaluminium Terminals ( Thimbles ) After Cutting The Worn Out / Faulty Cable End From Lt Pillar / Panel Box Including Necessary Earth Work For Taking Out The Cable From Loop Line, Returning, Filling In And Making Cable Lead By Providing Aluminium Lugsincluding Crimping With Crimping Tools In The Existing Lt Cable 25 Sqmm 4 Core Upto 50 Sqmm Including Necessary Connectioncomplete All As Specified & Directed. 71 All As Per Item Ser No 69 Here In Before But Size Of Lt Cable 70 Sqmm 3.5 Core Upto 120 Sqmm 3.5 Core Complete All As Specified & Directed. 72 All As Per Item Ser No 69 Here In Before But Size Of Lt Cable 150 Sqmm 3.5 Core Upto 300 Sqmm 3.5 Core Complete All As Specified & Directed. 73 Material And Labour For Shifting Heavy Items / Excavation / Cleaning Areas / Cleaning Site By Providing Crane / Hydra / Excavators / Tractors / Trolley Etc As Required At Site Complete All As Specified And Directed. 74 Material & Labour For Drilling Hole Of Any Size Manually As Per Site Requirement, Drilling For Laying Pipes Under The Road For Crossing Electrical Cable Complete All As Specified & Directed. 75 Material & Labourfor Spraying Herbicide ( Round Up ) On Area To Remove Unwanted Vegitation / Grass At Various Locations Complete All As Specified & Directed. 76 Supply And Fixing In Replacement Of On Load Change Over Switch With Sheet Steel Enclosure 415 V, 4 Pole, 630 Amps Capacity Fixed On Walls / Ms Frame / Pole / Lt Panel For Electric Supply Distribution Between Main And Dg Set Incl Necessary Connection Of Cable From Lt Panels To Change Over Switches Complete All As Specified & Directed.. 77 Taking Down Old Unserviceable Indicator Lamp Any Type Any Colour And Supply And Fixing New Indicator Red / Yellow / Green Including Making Electrical Connection With Suitable Size Of Copper Lugs Duly Crimped Complete All As Specified & Directed. 78 Re-Streching Of Loose Over Head Acsr Conductor Of Any Type / Gi Wire And Repair Of The Broken Conductors Andaddingnew Length ( If Required ) In Placeof Old And Burnt Conductor Of Any Size On Existing Poles With Proper Sagging Including Winding With Winding Wire All As Specified.Old Conductor Shall Be Reused Where Required For Repairing Broken Length Of Conductor Complete All As Specified & Directed.Note:- Each Run Of Conductor Will Be Measured And Paid Seperately. 79 Supply And Fixing In Replacement Of Sensor Of Nature Switch Operation Should Be Based On Natural Light Lux Level, Required Illuminance Level For Switching On Is <30 Lux And For Switching Off >10 Lux , The Sensor Should Also Have Part Night Operation Facility Of Min 4 Hrs To Max 12 Hrscomplete All As Specified And Directed Make:- Swadeep , Model Nature Switch -02 ( Sensor ) Or Equivalent As Approved By Ge. 80 Supply And Fixing In Replacement Of Contactor Three Pole 18 Amp In Street Light Timer Box Coil Operating Voltage 230 Volt Complete All As Specified And Directed Make- Bch / L&T Or Equivalent As Approved By Ge 81 Supply And Fixing In Replacement Of Contactor Two Pole 25 / 40 Amp In Street Light Timer Box Coil Operating Voltage 230 Volt Complete All As Specified And Directed Make- L&T / Bch Or Equivalent As Approved By Ge 82 Supply And Fixing In Replacement Ofcontactor Coil ( 230V ) For Mu Series 25 / 40 Amps 2 Pole Contactorscomplete All As Specified And Directed Make- L&T ( Cat No Cs90793 ) Or Equivalent As Approved By Ge 83 Supply And Fixing In Replacement Ofcontactor Coil ( 240V ) For Freedom Series 18 Amps 3 Pole Contactorscomplete All As Specified And Directed Make- Bch, Cat No Ce15d1n-K Or Equivalent As Approved By Ge 84 Supply And Fixing In Replacement Ofvms ( Voltage Monitoring Series ) In Street Light Timer Box, Including All Salient Features Such As Selectabe Under / Over Voltage Trip Levels, Protection Against Phase Loss & Natural Loss, Protecotion Against Phase Reversal And Phase To Phase Unbalance ( 10% ) , Voltage Sensing Principle And Led Indications For Power And Fault Conditions Complate All As Specified And Directed Make- L&T, Cat No Sm500 Or Equivalent Of Gic 85 Material And Labourforaluminium Conductor Steel Reinforced ( Acsr ) Conductor Of Size Isi Marked For Lt Over Head Lines On Poles Including Stretching, Tightining Of Poles Insulator With Winding Wire Of Suitable Size With Insulator / Strechingof Acsr Conductor Including Dismantling And Taking Down Old Unserviceable Acsr Conductor Incl Cutting, Welding Complete All As Specified & Directed. 86 Material And Labour For Vibratory Compactive, Precast Cement Concrete Rubber Moulded, Coloured ( Except Grey Colour ) , Interlocking Designer Paver Blocksin Milano Shape, Comfirming To Is-15658-2006 Of 60 Mm Thickness, M-35 Grade, As In Path, Hardingstanding, Etc Laid Over And Including 25 Mm Compacted Sand Cushioning, Including 75 Mm Thick Pcc 1:4:8 Type D-2 Using 40Mm Graded Crushed Stone Aggregate Including Surface Excavationover Area N. Exc. 30 Cm Deep And Averaging 15 Cm Deep And Getting Out In Soft / Loose Soil And Removing Excavated Soil Exc. 50 Mtr But N. Exc. 250 Mtr Includig Demolition Of Existing Paver Blocks, Complete All As Specified & Directed. 87 Earthing Complete With Galvanisedearth Plate Electrode 600Mm X 600Mmx 6.00Mm Thick Surrounded By Charcoal And Salt, Buried Directly In Ground Vertically In A Pit Of Depth Not Less Than 2.25M Belowground Level With Top Edge Of The Earthplate Not Less Than 1.5M Belownormal Groundlevel, Connected To 25X4 Mm Gi Strip Earth Lead By Means Of Bolts, Nuts, Checks Nut And Washers Made Out Of Galvanized Iron Or Steel, Earth Wire Protected By Galvanized Steel Pipe 40Mm Bore Medium Grade And Connected To Main Switch Or Main Control Board All As Shown In Electrical Plate No.3 Of Ssr Part-I & Including Necessary Excavation And Earth Work. The Rate Also Include Charcoal & Salt In Alternate Layers, 20Mm Bore Gi Pipe Medium Grade For Watering And 40Mm Bore Giprotection Pipe ( Light Grade ) , Funnel, Wire Mesh, Cast Iron Cover Andframe Etc, Complete, All As Specified Or Indicated And As Directed Including Testing On Completion Including Dismantalling Of Old U / S Earthing Complete All As Specified And Directed.Note : ( I ) The Quoted Rate Shall Include The Cost Of Earth Work, Gi Pipe For Watering, Gi Protection Pipe, Funnel, Wire Mesh, Rcc Cover, Etc. Complete. Rcc Cover Shall Be 50Mm Thick In 1:2:4 Type B-1 Using 8Mm Bars @10Cm C / C Both Way. ( Ii ) The Quoted Rate Shall Include The Cost Of The Earth Pit Covers To Be Conspicuously Marked Of Plate With Standgrouted In Pcc. ( Iii ) On Testing After Completion If The Desired Earth Resistanceis More Than 2?The Earthing Will Be Redone At No Extra Cost 88 Supply And Fixing In Replacement Indoor / Outdoor End Termination Joint Heat Shrinkable 1100 Volts For Xlpe Cable Of Size 3.5 / 4.0 X 10-50 Sqmm Including Complete All As Specified & Directed. 89 Supply And Fixingin Replacement Indoor / Outdoor End Termination Joint Heat Shrinkable 1100 Volts For Xlpe Cable Of Size 3.5 X 70-120 Sqmm Including Complete All As Specified & Directed. 90 Dismantling And Taking Down Old Unsv Lt Panel And Supply, Installing, Testing & Commissioning Outdoor Type Cubical Panel Board Of Size 1.2Mx1.0Mx.5M, Outer Shell Made Out Of3.15 Mm Thick Crca Sheet And Inner Shell Made Out Of 2 Mm Thick Crca Sheet And Ms Angle Section 50X50x6 Mm Mounted On Pcc 1:2:4 Type B-1 Platform 60 Cm Aboveand 45 Cm Below The Ground Level, Frame Factory Fabricated With Front And Back Openable Double Door System And Cable Alley ( Each Door Hinged With Body At 3 Places With Body And Hinges Should Be Welded With Body And Door ) Lockable / Open Ablewith Arrangement Of Pad Locking On Both Doors Incl 2 No. Of Pad Locks Of Three Keys Shall Be Used To Make The Outer Shell Completely Vermin Proof Suitable For 3 Phase 4 Wire 415 Volt, 50 Hz, Incl Copper Bus Bar Of 400 A , Tested At Factory Approved From Cpri Factory Fabricatedhaving Modern Fabrication And Testing Process Followed By Powder Coat Painting Having Thickness Not Less Than 100 Microns Provided With Suitable Gasket To Make It Dust / Vermin Proof And General Construction Confirming To Is:61439 / 2011Part-1 Andpart -2 Type Test Certificate With Not Less Thanip-56And Breaking Capacity 65 Ka Comprising Of The Following :- ( A ) Mccb400 Amps, 50 Ka 4 Pole 415 Volts Ac, Adjustable Type, ( Incoming ) -01 No. ( B ) Mccb125 Amp, 415 Volt, 4 Pole, Breaking Capacity 25 Ka , Adjustable Type ( Outgoing ) -04 Nos. ( C ) Ryb Indication Led Type, 22.5 Mm Dia, Protected With Mcb Sp 2 Amp Showing 3 Phase Supply -03 Nos ( F ) Digital Ammeter Of Range 0-500 A, Auxiliary Voltage 230 Volts With Selector Switch -01 Nos ( G ) Digital Volt Meter Of Range 0-500 Volts, Auxiliary Voltage 230 Volts With Selector Switch -1 No ( H ) Misc Items Like Screws, Cable Tie, Copper Cable 1.5 / 2.5 Sqmm, Cabe Lugs, Sleeves, Glands Etc Complete Are Included In Quoted Rates. 91 Dismantling And Taking Down Old Unsv Lt Panel And Supply, Installing, Testing & Commissioning Outdoor Type Cubical Panel Board Of Size 1.2Mx1.0Mx.5M, Outer Shell Made Out Of3.15 Mm Thick Crca Sheet And Inner Shell Made Out Of 2 Mm Thick Crca Sheet And Ms Angle Section 50X50x6 Mm Mounted On Pcc 1:2:4 Type B-1 Platform Block Type 60 Cm Above Ground Level And 30 Cm Grouting In Ground, Frame Factory Fabricated With Front And Back Openable Double Door System And Cable Alley ( Each Door Hinged With Body At 3 Places With Body And Hinges Should Be Welded With Body And Door ) Lockable / Open Ablewith Arrangement Of Pad Locking On Both Doors Incl 2 No. Of Pad Locks Of Three Keys Shall Be Used To Make The Outer Shell Completely Vermin Proof Suitable For 3 Phase 4 Wire 415 Volt, 50 Hz, Incl Copper Bus Bar Of 400 A , Tested At Factory Approved From Cpri Factory Fabricatedhaving Modern Fabrication And Testing Process Followed By Powder Coat Painting Having Thickness Not Less Than 100 Microns Provided With Suitable Gasket To Make It Dust / Vermin Proof And General Construction Confirming To Is:61439 / 2011Part-1 Andpart -2 Type Test Certificate With Not Less Thanip-56And Breaking Capacity 65 Ka Comprising Of The Following :- ( A ) Mccb315 Amps, 36 Ka 4 Pole 415 Volts Ac, Adjustable Type, ( Incoming ) -01 No. ( B ) Mccb100 Amp, 415 Volt, 4 Pole, Breaking Capacity 16 Ka , ( Outgoing ) -04 Nos. ( C ) Ryb Indication Led Type, 22.5 Mm Dia, Protected With Mcb Sp 2 Amp Showing 3 Phase Supply -03 Nos ( D ) Digital Ammeter Of Range 0-500 A, Auxiliary Voltage 230 Volts With Selector Switch -01 Nos ( E ) Digital Volt Meter Of Range 0-500 Volts, Auxiliary Voltage 230 Volts With Selector Switch -1 No ( F ) Misc Items Like Screws, Cable Tie, Copper Cable 1.5 / 2.5 Sqmm, Cabe Lugs, Sleeves, Glands Etc Complete Are Included In Quoted Rates. 92 Receiving / Recording Complaints Under Allenby Line Power House Of Perimeter / Security / Street Lights To Comprehensive Maintenance By Attendng Daily Complaints Including Sunday And Other Holidays For 08 Hrs And Making The Same Serviceable In All Respects Alongwith Replacement Of Any Major Part But Including Small Length Of Cable ( Not More Than 20 Mtr ) , Adhesive Tape And Other Connected Minor Accessories Shall Also Include To Visual Inspection. Quoted Rate Also Include Excavation Offaulty Cable Below The Pole And Making Seviceable With Accessories Of All Nature Like Faulty Light, Faulty Insulator, Broken Conductor & Cable Fault, Burnt Out Mcbs, Isolators, Switch Fuses, Service Cables Etc Sector `C-2`Areacomplete All As Directed To The Entire Satisfaction Of Engineer-In-Charge.Note ‘A’ :- ( I ) Any Complaint Left Unattended By The Electrician Shall Be Communicated To The Je In-Charge / Age E / M With Reason. No Charge Shall Be Paid For The Complaint Per Day Till The Complaint Is Resolved. ( Ii ) New Material / Stores Provided For Completing The Job Shall Be Measured And Paid For Separately Under Relevant Items Of Boq. ( Iii ) Contractor Shall Provide All Type Of T&P Of Lt Network, Bamboo Ladder ( 23 Feet ) With Safety Gloves To Electrician For Attending The Street Light Complaints ( Iv ) Contractor Shall Provide The Complaint Register 200 Pages – 10 No, Complaint Book With 100 Slips- 20 No. Booklets Serially Numbered In Triplicate. ( V ) Contractor Shall Provide 01 No. Experienced Electrician Having Minimum 5 Years Experience ( 01X 08 Hrs Per Day ) And 01 No. Helper Having Minimum 2 Years Experience ( 01 X 08 Hrs Per Day ) Including Sundays And Holidays To Attend The Complaints. ( Vi ) The Contractor Shall Provide Insurance Cover Of Minimum Rs 5 Lakh Per Head Under Ie Rules 2003 And Minimum Wages Act. ( Vii ) The Electrician And Helper Will Be Interview By Je E / M / Engr-In-Charge For Verification Of Experience, Character And Sound Mind And Body. ( Viii ) Cost Of Materials For Replacement Of Lights, Mcbs, Pole Junction Box, Brackets, Clamps, Insulator And Jumper Shall Be Measured And Paid Separately Under Relevant Items As Material & Labour. 93 Supply, Fixing And Testing Of Auto Day / Night On And Off Photocell.Ldr Sensor Switch 06 Amps For Lighting On And Off Photocell, Ldr Sensor Switch 6Amps For Lighting On And Off Water Proof 220Volt 50Hz, Ac Supply, Model No Quick Sense Qs-301 Complete With All Accessories Internally Pre-Wired Including Connection With 1.5Sqmm Copper Conductor From Main Supply To Sensor, Sensor To Fittings Including Taking Down Existing Complete All As Specified & Directed.. 94 Supply, Fixing And Testing Of Auto Day / Night On And Off Photocell.Ldr Sensor Switch 10 Amps For Lighting On And Off Photocell, Ldr Sensor Switch 6Amps For Lighting On And Off Water Proof 220Volt 50Hz, Ac Supply, Model No Quick Sense Qs-301 Complete With All Accessories Internally Pre-Wired Including Connection With 1.5Sqmm Copper Conductor From Main Supply To Sensor, Sensor To Fittings Including Taking Down Existing Complete All As Specified & Directed.. 95 Note:-Amount Of Credit Ofrs. 105485.00 For Retrieved Materials Is Mentioned In Schedule Of Credit Of Tender Documents In Pdff Form Which Will Be Deducted Offline While Acceptance Of Tender.
BRR : 9629534
Tender For Repair/ Maintenance Of Internal Electrification And External Water Supply At Parundu, External Electric Supply At 4N Det And External Water Supply At 7N Detunder Ge Tirunelveli.; 1 Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc., removing materials to store for keeping in safe custody for taking creditand making good disturbed surfaces of walls, floors etc. 2 Point wiring with 1.5 sqmm (Nominal area) unsheathed multi-stranded copper conductor PVC insulated cable 1100 volts grade single core drawn into and including non-metallic rigid PVC conduit of 20 mm dia/ PVC Casing cappingalong with 1.5 sqmm unsheathed multi stranded copper conductor cable PVC insulated 1100 volts grade as earth continuity conductor connected to common earth dolly fixed to wall/ ceiling roof with and including 1.6 mm thick MS sheet fabricated terminal boxes flush mounted for mounting the switches, sockets, fan regulator etc as required with 3mm thick laminated hylum sheet top cover all as specified and directed for :- 3 One light point controlled by one switch 4 One fan point controlled by one regulator / switch 5 One 3 pin socket outlet 5 amps socket onindependent board 6 One 3 pin socket outlet 5 amps socket on Same Board 7 One light point controlled by two Nosof two way switches 8 One bell/buzzer point controlled by one push button 9 All description as per item No. 2 here-in-before but with 2.5 sqmm cable for one 3 pin socket outlet 15 Amps on independent board with 2.5 sqmm cable as earthing conductor complete all as specified and as directed. 10 Supply and fix in replacement switch flush type single pole two way 5 A 240 Volts complete all as specified and as directed. 11 Supply and fixing in replacement Socket outlet 2 in 1, 3 pin, 5A complete all as specified and as directed. 12 Supply and fix in replacement switch piano flush type single pole one way 5 A 240 Volts complete all as specified and as directed. 13 Supply and fix in replacement switch Socketcombination 2 in 1,5 Amps Flush type 240 Voltscomplete all as specified and as directed. 14 Supply and fix in replacement switch Socketcombination 5 Amps / 16 amps, 5 in 1 flush type 240 Voltscomplete all as specified and as directed. 15 Supply and fix in replacementceiling rose3 ways PVC / Polycarbonate, isolated body complete all as specified and as directed. 16 Supply and fix in replacement Call bell, ding-dong, suitable for working on 230 volts AC supply, single pole, complete all as specified and as directed. 17 Supply and fix in replacementStepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc completeall as specified and as directed. 18 Supply and fix in replacement Bell push flush type5 A 240 Volts complete all as specified and as directed. 19 Supply and fix inreplacement Modular switch 1 way 5A, 1 Module complete all as specified and as directed. 20 Supply and fix inreplacement Modular switch 1 way 16A, 1 Module complete all as specified and as directed. 21 Supply and fix inreplacement Modular bell push ,5 A, 1 Module complete all as specified and as directed. 22 Supply and fix inreplacement Modular Socket 5A-2/3 pin combined 2 Module complete all as specified and as directed. 23 Supply and fix inreplacement Modular Socket5A / 15A - 2 / 3 pin combined 2 Module complete all as specified anddirected 24 Supply and fix in replacement Modular fan regulator step type , 2 Module complete all as specified and as directed. 25 Supply and fix inreplacement Modular switch 2 way 5A, 1 Module, flush type complete all as specified and as directed. 26 Taking down carefully old unserviceable sub main wiring with aluminum /copper conductor cable 4/6 Sqmm in PVC conduit complete removing the materials and taken as credit and making good the disturbed surface of wall / floor etc. 27 Material and labour for sub main wiring with two run single core4 sqmm multi stranded copper conductor FRLS-H PVC insulated unsheathed cable 1100 volts grade and one run of 4 sq mm multi stranded copper conductor FRLS-H cable as earth continuity conductor drawn into and including non-metallic rigid PVC conduit 20 mm dia/PVC casing capping 20 mm including conduit accessories all as specified and directed.Note: Three runs of 4 Sqmm cable and one run of 20mmconduit / casing capping will be measured as one unit length. 28 Material and labour for sub main wiring with two run single core 6 sqmm multi stranded copper conductor FRLS-H PVC insulated unsheathed cable 1100 volts grade and one run of 6 sq mm multi stranded copper conductor FRLS-H cableas earth continuity conductor drawn into and including non-metallic rigid PVC conduit 32 mm dia/PVC casing capping 25 mm including conduit accessories all as specified and directed.Note: Three runs of 6 Sqmm cable and one run of 25 mm conduit / casing capping will be measured as one unit length. 29 Material and labour for sub main wiring with four runs single core 6 sqmm multi stranded copper conductor FRLS-H PVC insulated unsheathed cable 1100 volts grade and one run of 6 sq mm multi stranded copper conductor FRLS-H cableas earth continuity conductor drawn into and including non-metallic rigid PVC conduit 32 mm dia/PVC casing capping 25 mm including conduit accessories all as specified and directed.Note: Five runs of 6 Sqmm cable and one run of 25 mm conduit / casing capping will be measured as one unit length. 30 Supply and fix in replacement Sheet metal enclosures with socket plug top and MCB SPN 20A, 240 volts, with a two pin and earth plug socket complete with one single MCB 20 Amps, 240 volts (for AC )complete all as specified and directed. 31 Supply and fix in replacement sheet metal enclosure powder coated double doorfor Distribution Board, SPN 4 way DB,240 V with detachable Gland Plate, Box Insertion Marks ,Circuit Identification Label ,Neutral Link ,Earth Link , Tin Plated Copper Bus Bar including , Disconnecting electric connections,complete all as specified and as directed. 32 Supply and fix in replacement sheet metal enclosure powder coated double doorfor Distribution Board, SPN 8 way DBwith 200 A bus bar ,240 V with detachable Gland Plate, Box Insertion Marks ,Circuit Identification Label ,Neutral Link ,Earth Link , Tin Plated Copper Bus Bar including , Disconnecting electric connections, complete all as specified and as directed. 33 Supply and fix in replacement sheet metal enclosure powder coated double door forDistribution Board,SPN 12 wayDB ,415 V with detachable Gland Plate, Box Insertion Marks ,Circuit Identification Label ,Neutral Link ,Earth Link , Tin Plated Copper Bus Bar including , Disconnecting electric connections, complete all as specified and as directed. 34 Supply and fix in replacement sheet metal enclosure powder coated double door forDistribution Board,TPN 4 wayDB ,415 V with detachable Gland Plate, Box Insertion Marks ,Circuit Identification Label ,Neutral Link ,Earth Link , Tin Plated Copper Bus Bar including , Disconnecting electric connections, complete all as specified and as directed. 35 Supply and fix in replacement sheet metal enclosure powder coated double door forDistribution Board,VTPN 4 wayDB with IP 43-IK 09 ,disconnecting electric connections, complete all as specified and as directed. 36 Supply and fix in replacementMCB SP 5 A to 32 A, B curve, 10 kA including , Disconnecting electric connections,completeall as specified and as directed. 37 Supply and fix in replacementMCB SPN 32 Amps, C curve 10 kAincluding , Disconnecting electric connections,completeall as specified and as directed. 38 Supply and fix in replacementMCB TP25A - 63 A, C curve 10 kA including , Disconnecting electric connections,completeall as specified and as directed. 39 Supply and fix in replacementMCB TPN 16 A- 32 Amps, C curve 10 kAincluding , Disconnecting electric connections,completeall as specified and as directed. 40 Supply and fix in replacementMCB TPN40A- 100 A, C curve 10 kA including , Disconnecting electric connections,completeall as specified and as directed. 41 Supply and lay earth continuity conductor or main earthing lead fixed to wall on batten or recess or buried in ground or drawn in conduit / conduit pipe or fixed to poles or any other indicted situation for loop earthing etc of galvanised steel earth stripof size 32 X 6mm including taking down old unserviceable earth strip complete for taking into credit complete all as specified and as directed by the Engineer-in-Charge 42 Supply and fix in replacement Lightning Protection Single point air termination aluminum rod 12mm dia 300mm long with base plate complete all as specified and as directed by the Engineer-in-Charge . 43 Supply and fix in replacement Test point terminal box made out of Gun metal or Phosphorous bronze of size 75x75x25mm drilled and screwed including 3 Nos. 8mm dia 25mm long hex head screwscomplete all as specified and as directed by the Engineer-in-Charge . 44 Supply and fix in replacement Aluminium strip of 25x 3.15mm fixed with screws/ clamps / insulators for roof conductors and down conductors above ground level complete all as specified and as directed by the Engineer-in-Charge. 45 Supply and fix in replacement MCCB3 pole 415 volts25 to100 Amps, with rupturing capacity 16 KA complete all as specified and as directed 46 Supply and fix in replacement MCCB3 pole 415 volts125 Amps, with rupturing capacity 16 KA complete all as specified and as directed 47 Taking down geyser of any make/ type and any capacity after disconnecting the water and electric line connections from any height, bringing down to floor, dismantling the Geyser and overhauling by means of repair/replacement of the defective spares, cleaning externally and internally re-assembling the geyser, fixing in same position and testingfor satisfactory working etc complete.Note:Replacement of defective spares shall be measured and paid under relevant item separately. 48 Supply only Neon lamp indicator (Green and Red) 49 Supply only Bottom flange with inlet and outlet pipe (Apparatus plate) 50 Supply only Thermostat conforming to IS 3017 51 Supply only Flexible connection pipe set of two for cold and hot water 52 Supply only Heating element 2.0 KW 53 Supply Siphon assembly 54 Supply and fix Modular switch SP 1 way 16 Amp with indicator complete all as specified and as directed 55 Taking down ceiling fan 1200mm/1400mm sweep from any height and bringing down to floor, dismantling the ceiling fan and overhauling by means of replacing defective ball bearing, bushes, split pins, grease, packing, winding and cleaning externally, re-assembling the ceiling fan and checking, refixing in its position complete all as specified and directed.Note: (i) Rewinding, replacement of bearing and capacitors shall be measured and paid separately.(ii) All other petty repairs used for this work shall be included in the quoted rate. 56 All as per item No.55 but for exhaust fan 300mm including replacing of rusted nut and bolts complete all as specified and directed. 57 All as per item No.55 but for exhaust fan 450 mm including replacing of rusted nut and bolts complete all as specified and directed. 58 Supply and fix ball bearing suitable for any sweep ceiling fan complete all as specified and directed. 59 Material and labour for rewinding with super enameled copper wire including varnishing, drying and connection complete all as specified and directed. 60 Material and labour for painting of ceiling fans at site with synthetic enamel paint by spray painting including filing cavities with filler in one coat after cleaning dust complete all as specified and directed. 61 Supply and fixing exhaust fan heavy duty 250mm sweep plastic body 900RP, 230V, 50 Hz with louvers, cutting the wall and fixing all as specified and directed.(Note Old exhaust fan to be deposited after taking down to MES store) 62 Supply and fix in replacement louvers for exhaust fan of any sizeincluding taking down old unserviceable louvers and removing the material for taking credit complete all as specified and directed. 63 Supply and fix in replacement Condensor 2.5 to 4 mfd for Ceiling/exhaust fan, including taking down old unserviceable material for taking credit complete all as specified and directed. 64 Supply and fixin replacementFlame proof switch socket &plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earthcomplete all as specified and directed. 65 Supply and fixin replacement Switch flame proof rotary type with termination box in LM6, 16A, single pole 250Vcomplete all as specified and directed. 66 Supply and fix in replacement LED lights fitting 1x 20 W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose completeall as specified and directed 67 Supply and fixing LED light fitting in replacement 1x9W/1X10W bulkhead luminaries including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed 68 Supply and fix in replacementLED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed 69 Supply and fix in replacement LED luminaries 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed 70 Supply and fix in replacement round shape 6 watt (6 inch) 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed 71 Supply and fix in replacement round shape 12 watt (8 inch) 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed 72 Supply and fix in replacement square shape 300x30mm size 15 watt220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed 73 Supply and fix LED1x4 feet, 40Watt, recess mounted light fitting environment friendly, new generation, aesthetically designed ultra modern with high transmitive diffuser suitable for indoor spaces complete all as specified and directed 74 Supply and fix LED in replacement vertical mounting integral highbay/medium bay in hangar ceiling at 10 metre height LED IP65lumnnaire,luminous flux 15000 luminous efficacy 150 lmW, IK 08 surge protection luminaries surge protection level until 4kV along with necessary chain, hooks to hold the bolt and hang the light fitting complete all as specified and directed 75 Supply and fix in repairs LED Security light fitting 35 W LEDcomplete with all accessories internally pre wired and connecting up with twin / three core flexible copper conductor cable of suitable size from ceiling rose to fitting etc, including necessary bracket complete all as specified and as directed. 76 Supply and fix in replacement LED light fitting 2x 16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size including all accessoriescomplete all as specified and as directed. 77 Providing comprehensive annual maintenance periodical/preventive maintenanceincluding annual maintenance of cooling appliances ( Split type Air Conditioners, Water coolers, Refrigerators and Deep Freezers) as per manufacturer specificationby providing one AC/Refrigeration mechanic including replacement ofcomponents as listed in subsequent items here in after. The maintenance of cooling appliances includes the following:-(a) Cleaning of coil unit with dust blower, lubricate the indoor and outdoor fan motor with oil.(b) Cleaning of air filters, indoor unit grillSupply and fixingilters through air blower.(c) Checking and cleaning the drain connection and air filter periodically, washing of coil with ventiklean solution once in a contract period.(d) Check and replace the refrigerant pipe once in a contract period or as and when required.(e) Check and repair the minor electrical fault in incoming supply.(f) Check and replace the water PVC pipe.(g)Replacementof faulty spares/components(h) Carry out the monthly, quarterly and annual maintenance of all cooling appliances of any make & capacity with job card and making the Cooling Appliances functional(Each Job contains 3 Complaints) 78 Supply only the following new items for 1.5 / 2.00 Ton CapacitySplit type AC including testing and commissioning etc complete all as directed. 79 Capacitor 36/45/50 MFD. 80 Air filters. 81 Outdoor fan motor 82 Indoor fan motor 83 Indoor blower 84 Copper condenser coil unit (for A/C) 85 Indoor motor capacitor 2.5 MFD. 86 Outdoor fan motor capacitor 3 to 6 MFD 87 Non return valve (For gas top up charging) 88 Remote control suitable forinverter model Split AC. 89 Electronic components for repairs to PCB 90 PCB board suitable for indoor unit of Inverter model split AC 1.5/2.0 TR . 91 PCB board suitable for outdoor unit of Inverter model split AC 1.5/2.0 TR . 92 Copper pipe of size 1/2 for suction line with foam insulation 93 Copper pipe of size 1/4 for discharge line with foam insulation 94 Swing Motor for indoor unit 95 Supply and fixPVC insulated unsheathed cables of size 2.5 sqmm 3 core multi-stranded Copper conductor wire suitable for AC complete all as specified and as directed. 96 Supply and fixMetal plug top for AC 97 Supply and fixing compressor including pumping out oil, cleaning the refrigeration system with CO2 and charging refrigerant gas (M-22/F-22) providing NRV for further topping up of gas and re-fixing in the position including complete testing and commissioning all as directed for the following appliances :- 98 Split type AC 1.5 Ton capacity. 99 Material and labour for SPN enclosure with two pin and earth plug and socket with 240 volts 20 Amp SPMCB, complete all as specified and directed by Engr-in charge. 100 Supply and fix in repairs LED Security light fitting 25 W LEDcomplete with all accessories internally pre wired and connecting up with twin / three core flexible copper conductor cable of suitable size from ceiling rose to fitting etc, including necessary bracket complete all as specified and as directed. 101 Supply and fix in replacement flat panel 36 watt 2x2 feet 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed 102 Excavating in trenches, not exc 1.5m wide and not exc 1.5m in depth; for laying pipes and getting out in any type ofsoil, complete all as specified 103 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil, complete all as specified 104 Removing excavated soils n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and as directed by the Engineer-in-Charge. 105 Spreading of riddled earth obtained from trenchesfor cable cushioning on top and bottom of cable as specified for cable protection complete all as specified and directed. (Note: Only punned thickness of riddled earth shall be measured) 106 Supply and laybricks in trenches , common burnt clay building bricks, subclass `B’ designation 75, old size ,with width equal to thelength of the brick; complete all as specified and directed. 107 Supply and fix in replacement MCCB4 pole 415 volts63 Amps, with rupturing capacity 16 KA complete all as specified and as directed 108 Supply and fix in replacement MCCB4 pole 415 volts100 Amps, with rupturing capacity 16 KA complete all as specified and as directed 109 Material and labour in replacement of GI pipe light grade of size 80mm diafor protection of UG cable on walls/under floors/road crossings/in trenches complete all as specified and as directed by the Engineer-in-Charge . 110 Servicing of high mast light control gear suspension system with stainless steel wire rope guage and double drum winch with luminaries mounting arm pulley assembly complete all as specified and directed by Engr-in-charge. 111 Supply and fixing in replacement LED flood light 150Watt 230V AC outdoor type with thermal management in multiple optics and equipped with IP6 protectionwith impact and corrosion resistant complete with driver and lamp complete all as specified and directed by Engr-in-charge. 112 Supply and lay LT under ground cable 1100 volts grade Cross linked Polyethylene (XLPE) insulated PVC Sheathed Cables 3.5 core 70 sqmm, armoured multistranded heavy duty electric cable with aluminium conductor laid in trenches/ duct / walls including cable gland and lugs on both end termination including laying, connecting to various switches inpanel board, testing and commissioning complete all as directed & as specified. 113 Supply and fixing L bus bar box outdoor type made up of MS sheet 3mm thk of size 600x500x300mm CPRI approved with supporting angle of size 50x5xmm, 800mm long with nut, bolts and washers of suitable size for fixing on ground with PCC 1:3:6 mix, 20mm aggregate for foundation providing Aluminum bus bar 400m long and 40x5mm thick, 04 nos with supporting insulators and colour coded PVC sleeves including necessary bottom plat whole for entry o cables complete all as specified and directed. 114 Supply and fix in replacementGI tubingmedium gradeincluding provision of necessary fittings like Tee,Bend,Socket,Elbow, Short pieces connectors, plugs, unions, etc and accessories laid in trenchesall as specified and directed by Engineer-in-Charge of following bore sizes:- 115 (a) 20 mm bore steel tubing 116 (b) 25 mm bore steel tubing 117 (d) 40 mm bore steel tubing 118 (e) 50 mm bore steel tubing 119 (f) 80 mm bore steel tubing 120 Supply and FixingGI tubingmedium grade including provision of fittings like Tee,Bend,Socket,Elbow, Short pieces connectors, plugs, unions, etc and accessories on walls/roofs all as specified and directed by Engineer-in-Charge of following bore sizes:- 121 (a) 20 mm bore steel tubing 122 (b) 25 mmbore steel tubing 123 (d) 40 mm bore steel tubing 124 (e) 50 mm bore steel tubing 125 Monthly testing of potable water samples for checking fitness for drinking purposeat the district water testing lab complete all as specified and directed. 126 Monthly testing of raw water/potable water samples for checking fitness for domestic consumption at the district water testing lab complete all as specified and directed. 127 Supply and fixing of gun metal gate valve, painted finish, with forged brass spindle and iron wheel head, screwed both ends internally IS-778 marked, Class-2,for iron pipe of following sizes complete all as specified and directed. 128 (a) 20 mm bore 129 (b) 25 mmbore 130 (c) 32 mmbore 131 (d) 40 mm bore 132 (e) 50 mm bore 133 Supply and fix in repairbrass float valve, ISI marked high pressure with polythene float and fly nut complete, screwed of following size / bore including necessary GI fittings such as elbow, reducer, nipple complete all as specified and directed. 134 (a) 20 mm dia 135 (b) 25 mm dia 136 (c) 40 mm dia 137 (d) 50 mm dia 138 Supply and fix Pressure gauge 5 dia, 0 to 14 Kg/cm2 range fixing on delivery pipe of pump set and removing existing defective pressure gauge and taken as credit complete all as specified and as directed. 139 Supply and fixsluice valves flanged end, cast iron body, flanged and drilled and non rising type stainless steel spindlewith nut, long body, class P N 1.6, conforming to IS 14846 of 2000 for following sizesincluding all flange joint with rubber or fiber board, bolts, nuts and washers complete including pumping out accumulated water all as specified and directed by Eng-in-Charge of following sizes. 140 (a) Sluice Valve, Class PN 1.6, 63mm dia 141 (b) Sluice Valve, Class PN 1.6, 80mm dia 142 (c) Non Return Sluice Valve, 80mm dia 143 Supply and fixFoot Valve screwed / flanged including necessary fittings like connectingflanges of following sizes. 144 (a) Foot Valve 50 mm dia 145 (b) Foot Valve63 mm dia 146 Replacement of GI flange having holes(ISI marked) suitable for 40mm bore pipe including jointing material such as rubber gasket bolt units and washers etc in place of unserviceable all as directed. 147 All as per item No.106 above but Suitable for 50 mm bore pipe 148 All as per item No.106 above but Suitable for 80 mm bore pipe 149 Replacement of GI union of both end lock nut screwed with leak proof washer connected to existing GI tubing of 20mm bore completeall as directed. 150 All as per item No.109 above but Suitable for 25 mm bore pipe 151 All as per item No.109 above but Suitable for 40 mm bore pipe 152 All as per item No.109 above but Suitable for 50 mm bore pipe 153 Material and labour forby scraping / cleaning with wire brushes to remove the old painting from pump, motor, coupling guard, MS common base frame and painting with two coats of synthetic enamel paint of approved quality over a coat of red oxide primer as specified below here in after for pump sets:-(a)Motor and pump - Smoke Grey colour (b) Coupling guard and motor air grill - Post office Red colour.(c)Common base frame - Black colour (d)Suction line and delivery line in side pump house - Navy blue colour for fresh water pipe lines. 154 Taking down defective mono block / Centrifugal pump setfrom foundation by opening of coupling and foundation bolts and transporting to workshop for repairing and reassembling after servicing and overhauling complete with oiling/greasing, lubricating the parts including repair / replacement of worn out parts and replacement of base foundation nuts and bolts and re-installing ,necessary electrical connection and testing for satisfactory performance complete all as specified and directed by Engineer - in - Charge.for electric driven pump set of 1 / 2 HP capacity Note:- (i) The rate quoted for this item shall includes labour charge only for main repair and replacement of defective/UNSV spares/accessories. Spares are to measured and paid separately under subsequent items.(ii) Cost of other minor items/spares such as nut, bolts washers, gaskets,etc which are not covered under Sch A but required for effective functioning of the plant shall be deemed to included in this item. (ii) The cost of spares shall be paid under relevant items given below(iii)In case of any damage to thepipes during the time of removal of the pump set ,contractor shall be responsible for repairing the same without any extra cost to the government. 155 Rewinding of motorcoil complete as per IS-396 of 1953 using super enamelled copper wire ofadequate gauge and weight including replacement of all insulation material and terminal lead for power supply and other petty items required for making motor functional. 156 Supply onlyBall bearings (drive and non drive end)Make 157 Supply onlyElectro dynamically balanced bronze impeller 158 Supply onlyImpeller Key 159 Supply onlyWater Seal 160 Supply only Terminal connection with terminal box 161 Supply only Condensor suitable capacity / MFD 162 All as per item No 114 herein before but pump set of capacity 3 HP Note: The cost of spares shall be paid under relevant items given below as Supply only. 163 Rewinding of motorcoil complete as per IS-396 of 1953 using super enamelled copper wire ofadequate gauge and weight including replacement of all insulation material and terminal lead for power supply and other petty items required for making motor functional. 164 Supply only Ball bearing (Drive and Non drive end) 165 Supply only Cooling fan blade 166 Supply only Cooling fan cover with suitable screws 167 Supply only Terminal box with terminal connection 168 Supply only Electric dynamically balanced bronze impeller 169 Supply only Shaft mild steel 170 Supply only Gun Metal bush 171 Supply only Gland cup with bolts and nuts 172 Supply only Flange drilled suitable size with bolts, nuts and washersincluding rubber gasket 173 Supply only Air cock nozzle brass 174 Supply only Shaft coupling 175 Supply only chlorine test kit. 176 Supply only impeller key 177 Supply only water seal 178 Supply only Condensor of suitable capacity/MFD 179 Supply only Calcium Hypochlorite 65% to 70% Chlorine content in granular form (Calcium based Granular disinfectant for water treatmentof drinking water ). Packed in 45 Kgs each Drum. Make:- Sree Rayalaseema Hi Strength Hypo Ltd.(Brand :- PURI CHLOR)or approved by NMPT Committee of E-in-Cs Branch.Note:- The contractormust submit the NSF Certificate of the product, FSSAI Registration and COC (Certificate of Compliance) in original from manufactures by All India Authorized MES Distributor for each batch of product delivered indicating. Including chemical analysis report by all India authorized MES Distributor. Product must have min. 65% Chlorine Contents suitable for Human Consumption. 180 Material and Labour Cleaning valve chamber of any size by removing all unwanted particles such as mud, sand, dust, dirt, decayed leaves etc. and applying two coats of white wash to all internal and external surfaces of valve chamber all as directed by Engineer-in-charge. 181 Material and labour for disconnectany size/ model of pump set from the foundation bed to carry out minor repair work such as greasing, gland rope packing, nut & bolts, washers and flanged and complete the correctrotational alignment for smooth functioning all as directed by the Engr-in- charge. 182 Supply and fix Gland rope (graphite rope ) (size 1/2,1/4,3/4) suitable for pump size 1 HP-5 HPincluding taking out old unserviceable all as directed. 183 Supply and fix Gland rope (graphite rope ) (size 1/2,1/4,3/4) suitable for pump size 2HP-5 HPincluding taking out old unserviceable all as directed. 184 Supply and fix Gland rope (graphite rope ) (size 1/2,1/4,3/4) suitable for sluice valve 63/80mm diaincluding taking out old unserviceable all as directed. 185 Removal of dust and cleaning the Earth pitand washingthe same, applying one coat of white wash , writing the letters such as for Pump set Numberas required at sitewith enamel paint of black colour on pit cover complete all as specified and as directed. 186 Material and labour for Sub main wiring with four runs single core 4sqmm multi stranded copper conductor PVC insulated unsheathed cable 1100 volts grade and two runs of 4 sqmm multi stranded copper conductor cable as earth continuity conductor drawn into and including non-metallic rigid PVC conduit, 25mm dia/PVC casing capping 32 mmand conduit accessories concealed/surface of wall/roof/ceiling etc complete all as specified and directed.Note: Four runs of 4sqmm and two runs of 4 sqmm cable and one run of 25mm dia conduit/casing capping shall be measured as one unit length. 187 Cutting existing bituminous road and excavating in trenches, not exc 1.5m wide and not exc 1.5m in depth by cutting existing bituminous road not exc 10 sq. m on plan and not exc 1.5m in depth and getting out in any type ofsoil, complete all as specified 188 Demolition of cement concrete (unreinforced) in ground floors and pavings n exe 15 cm thickness (below or above ground level) complete all as specified and as directed by the Engineer-in-Charge. 189 Material and labour for 100 mm thick cement concrete 1:2:4 type B-1, using 20mm graded aggregate for making good the disturbed road surface after laying of pipe line over returned filled and compacted earth surface to match with existing road level complete all as specified and as directed. 190 Material and labour for preparation of new steel surface and applying two coats of approved colour synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. 191 Material and labour for attending breakdown complaints like no water supply in service tank, pipe line leakages etc and also removing air lock in OTM/Single living accommodations with help of required tools and man power with items like GI fittings of any size/dia, union, elbow, tee, bend, nipple, socket etc including excavation upto 1.0 cum if required for rectification of leakage of GI pipe all as specified and directed.Note:-(i) Rate of items like union, elbow, nipple ,coupler, bend socket shall be included in the unit quoted rate.(ii) Rate of excavation upto 1 cum shall be included in the unit quoted rate. 192 Taking down defective mono block / Centrifugal pump setfrom foundation by opening of coupling and foundation bolts and transporting to workshop for repairing and reassembling after servicing and overhauling complete with oiling/greasing, lubricating the parts including repair / replacement of worn out parts and replacement of base foundation nuts and bolts and re-installing ,necessary electrical connection and testing for satisfactory performance complete all as specified and directed by Engineer - in - Charge.for electric driven pump set of 5 HP capacity Note:- (i) The rate quoted for this item shall includes labour charge only for main repair and replacement of defective/UNSV spares/accessories. Spares are to measured and paid separately under subsequent items.(ii) Cost of other minor items/spares such as nut, bolts washers, gaskets,etc which are not covered under Sch A but required for effective functioning of the plant shall be deemed to included in this item. (ii) The cost of spares shall be paid under relevant items given below(iii)In case of any damage to thepipes during the time of removal of the pump set ,contractor shall be responsible for repairing the same without any extra cost to the government. Note: The cost of spares shall be paid under relevant items given below as Supply only. 193 Rewinding of motorcoil complete as per IS-396 of 1953 using super enamelled copper wire ofadequate gauge and weight including replacement of all insulation material and terminal lead for power supply and other petty items required for making motor functional. 194 Supply only Ball bearing (Drive and Non drive end) 195 Supply only Cooling fan blade 196 Supply only Cooling fan cover with suitable screws 197 Supply onlyTerminal box with terminal connection 198 Supply only Electric dynamically balanced bronze impeller 199 Supply only Flange drilled suitable size with bolts, nuts and washers including rubber gasket 200 Supply only Air cock nozzle brass 201 Supply only Shaft coupling 202 All as per Slitem No : 152herein before but defective open well submersible pump set of capacity1 HP/2 HP1 Ph, 240 Voltsincluding taking up the pump set fromopen well/UG sump after disconnecting the electrical and pipeline connection, completewithout any damage to the pump set or thepipes and transporting to workshop including repair/replacement of worn out parts, servicing and overhauling complete with oiling/greasing, lubricating the parts and reassembling and painting of submersible pump set with motor with two coat of synthetic enamel paint over a coat of red oxide after clearing and scrubbing and shifting back to bore well, lowering commissioning and testing on full load complete all as specified and directed by Engineer-in-charge.Note: In case of any damage to thepipes during the time of removal of the pump set ,contractor shall be responsible for repairing the same without any extra cost to the government. 203 Rewinding of motorcoil complete as per IS-396 of 1953 using super enamelled copper wire ofadequate gauge and weight including replacement of all insulation material and terminal lead for power supply and other petty items required for making motor functional. 204 Supply only Thrust bearing 205 Supply only Electro dynamically balanced bronze impeller 206 Supply only Gun Metal bush 207 Supply only Gland Cup with bolts and nuts 208 Supply only GI Flange drilled suitable size bolts, nuts, washers and rubber gasket 209 Supply only Shaft Mild steel 210 Supply only Rotor sleeve 211 All as per Slitem No 152 herein before but pump set capacity 5 HP . Note: The cost of spares shall be paid under relevant items given below as Supply only. 212 Rewinding of motorcoil complete as per IS-396 of 1953 using super enamelled copper wire ofadequate gauge and weight including replacement of all insulation material and terminal lead for power supply and other petty items required for making motor functional. 213 Supply only Thrust bearing 214 Supply only Electro dynamically balanced bronze impeller 215 Supply only Gun Metal bush 216 Supply only Gland Cup with bolts and nuts 217 Supply only GI Flange drilled suitable size bolts, nuts, washers and rubber gasket 218 Supply only Shaft Mild steel 219 Supply only Rotor sleeve 220 All as per Slitem No 152 herein before but Non- clogging submersible pump set capacity 7.5 HP . Note: The cost of spares shall be paid under relevant items given below as Supply only. 221 Rewinding of motorcoil complete as per IS-396 of 1953 using super enamelled copper wire ofadequate gauge and weight including replacement of all insulation material and terminal lead for power supply and other petty items required for making motor functional. 222 Supply only Thrust/ball bearing 223 Supply only Electro dynamically balanced bronze impeller 224 Supply only Cooling fan blade 225 Supply only terminal box with terminal connectors 226 Supply only Shaft Mild steel 227 Supply only Gun Metal bush 228 Cleaning the internal and external surface of UG sump / Static water tankof capacity up to 10000 gallons and well by scrapping/brushing and removing all silt dust etc from walls, floors, clean with water and bleaching powder and applying one coat of lime wash to all internal surfaces and complete removal of sand,dust.dirt and other unwanted coatings from the exterior wall surfaces by suitable means and painting with weather proof oil bound distemper to complete side wall and top surface of sump including writing particulars such as capacity of sump, date of cleaning and due date of cleaning etc using white paint on black back ground with height of letter to match with the existing size including painting to incoming and outgoing pipe lines and valves/valve chambers with approved colour (Pipe line exposed above surface) of any size complete all as directed 229 Cleaning the internal and external surface of Shallow well of size 4.50 mtr dia. and 6 mtr depth by scrapping/brushing and removing all silt dust etc from walls, floors, clean with water and bleaching powder and applying one coat of lime wash to all internal surfaces and complete removal of sand,dust.dirt and other unwanted coatings from the exterior wall surfaces by suitable means and painting with weather proof oil bound distemper to complete side wall of shallow well including writing particulars such as depth of shallow well, date of cleaning and due date of cleaning etc using white paint on black back ground with height of letter to match with the existing size including painting topipe lines and valves with approved colour (Pipe line exposed above surface) of any size complete all as directed 230 Cleaning the internal and external surface of deep Open well of size 7-10 mtr dia. and 10-15 mtr depth by scrapping/brushing and removing all silt dust etc from walls, floors, clean with water and bleaching powder and applying one coat of lime wash to all internal surfaces and complete removal of sand,dust.dirt and other unwanted coatings from the exterior wall surfaces by suitable means and painting with weather proof oil bound distemper to complete side wall of shallow well including writing particulars such as depth of shallow well, date of cleaning and due date of cleaning etc using white paint on black back ground with height of letter to match with the existing size including painting topipe lines and valves with approved colour (Pipe line exposed above surface) of any size complete all as directed 231 Cleaning the internal surfaces of Over Head Tank at 45 m height / staging by scrapping down/brushing and removing all silt dirt, algae etc from walls, floors, washing/ cleaning with water and applying one coat of white wash to all internal surfaces of walls and ceilings complete including writing particulars such as capacity of OH tank, date of cleaning and due date of cleaning etc using white paint on black back ground with height of letter to match with the existing size including painting to incoming and outgoing pipe lines and valves/valve chambers with approved colour (Pipe line exposed above surface) of any size complete all as directed all as directed by Engineer-in-charge for 100000 Litres capacity 232 Cleaning the internal surfaces of Over Head Tank at 15 m height / staging by scrapping down/brushing and removing all silt dirt, algae etc from walls, floors, washing/ cleaning with water and applying one coat of white wash to all internal surfaces of walls and ceilings complete including writing particulars such as capacity of OH tank, date of cleaning and due date of cleaning etc using white paint on black back ground with height of letter to match with the existing size including painting to incoming and outgoing pipe lines and valves/valve chambers with approved colour (Pipe line exposed above surface) of any size complete all as directed all as directed by Engineer-in-charge for 15000 Ltr capacity. 233 NOTE FOR SL ITEM NO 188 TO 192 -1. T & P for dewatering UG Sump / Static Tank has to be arranged by the contractor. Rate quoted is inclusive of material and labour required for dewatering. Nothing extra shall be paid separately. 2. All the operations should be executed by trained workers and technicians, properly dressed along with gum boots, safety harness to work as per the direction of Engineer in charge. Contractor shall bring suitable fittings to connect cleanout pipe and suitable length pipe using cleanout facility if available and operational without damaging water tank. Nothing extra shall be paid separately. Contractor shall be responsible for complete cleaning, suction, disposal activity and thereafter. Any damages to water tank during cleaning operation shall be repaired by the Contractor with no cost to MES. Contractor shall ensure and implement safe working conditions for his laborers during execution , all necessary safety measures and harness shall be used before taking-up work. Suitable lighting and ventilation should be provided by the contractor before cleaning of covered tanks. Agency shall be solitary responsible for the lapses in the safety during the work and allied compensations. Nothing extra shall be paid separately, etc. complete as per direction of Engineer In-charge. 234 Supply and fix Three phase direct online starter, suitable for 1 HP - 5 HP Pump/motor including necessary electrical connections and taking down old unserviceable all as directed. 235 Supply and fix Three phase direct online starter , suitable for7.5 HP Pump/motor. including necessary electrical connections and taking down old unserviceable all as directed. 236 Supply and fixSingle phase direct online starter, suitable for0.5 - 2 HP Pump/motor including necessary electrical connections and taking out old unserviceable all as directed. 237 Supply and fix single phase preventer 3 phase 415 voltsincluding taking out old unserviceable all as directed.. 238 Material and Labour Cleaning rain water collection well (depth 3 mtr: meant for collection of rain water and pumping away the collected water by submersible pumps of 7.5 HP during rainy season) by removing all unwanted particles such as mud, sand, dust, dirt, decayed leaves etc. and applying two coats of white wash to all internal and external surfaces of collection well including painting of submersible pumps 7.5 HP and connected pipe lines ( 2 Pump sets in each rain water collection chamber) with synthetic enamel paint of approved colour all as directed by Engineer-in-charge. 239 Supply and fix Gland rope (graphite rope ) (size 1/2,1/4,3/4) suitable for pump size 2HP-5 HPincluding taking out old unserviceable all as directed. 240 Supply and fix Gland rope (graphite rope ) (size 1/2,1/4,3/4) suitable for Sluice valves 63/80mm dia including taking out old unserviceable all as directed. 241 Supply and connecting flat three core, PVC insulated industrial Flat cable for submersible motor, 4 sqmm (Nominal area) with multi stranded copper conductor, 1100 volts grade connected from starter to submersible pump motor complete all as specified and directed. 242 Supply and connecting flat three core, PVC insulated industrial flat cable for submersible motor, 6 sqmm (Nominal area) with multi stranded copper conductor, 1100 volts grade connected from starter to submersible pump motor complete all as specified and directed. 243 Cutting existing bituminous road and excavating in trenches, not exc 1.5m wide and not exc 1.5m in depth by cutting existing bituminous road not exc 10 sq. m on plan and not exc 1.5m in depth and getting out in any type ofsoil, complete all as specified 244 Material and labour for rendering 10mm thickin cement mortar 1:6 on fair faces of brick work or concrete surfaces complete all as specified and as directed by the Engineer-in-Charge. 245 Material and labour for providing cement concrete 1:2:4 Type B0 using 12.5mm graded aggregate as in copings, complete all as specified and as directed by the Engineer-in-Charge. 246 Material and labour for fixing valve chamber cover in replacement, fabricated from MS sheet 3mm thickness, fixing Angle at all sides, with two Nos of hinges and one No. handle made out of MS round bar 10mm dia with necessary locking arrangement complete all as specified and as directed by the Engineer-in-Charge.
BRR : 8497156
Tender For Repairs/ Maintenance Of Security Lights, Garden Lights Gate Lights And Connected External Lighting Works At Af Station Gwalior.; 1 Labour only for checking the serviceability of different spares/ components/ parts of High mast light fittings (LED, HPSV, HPMV, Metal Halide fittings etc, any wattage/ capacity) of any description and in any position, replacement of un-serviceable/ damaged/ broken part(s) either in single or in combination, re-assembling the fittings and making the light fittings serviceable, fixing the fittings in position, cleaning acrylic/glass cover connecting to electric supply and its testing on installationetc complete all as specified and directed. 2 Labour only for checking the serviceability of different spares/ components/ parts of security/ light fittings (LED, HPSV, HPMV, Metal Halide fittings etc, any wattage/capacity) of any description and in any position, replacement of un-serviceable/damaged/ broken part(s) either in single or in combination, re-assembling the fittings and making the light fittings serviceable, fixing the fittings in position, cleaning acrylic/glass cover connecting to electric supply and its testing on installationetc complete all as specified and directed by Engineer-in-Charge. NOTES FOR SCH `A’ ITEM NO 1 & 2:-(i) Fixing charges for Spare Parts of the new & old replaced part(s) is deemed to be included in the rates quoted by the contractor for above item and cost of new parts shall be measured and paid separately as supply only against respect items of Sch ‘A’. (ii) Necessary T&P i.e. ladder, tools,Vehicles etc required for checking and making the light fittings in serviceable conditions, its fixing in position and testing shall be arranged by the contractor at his own cost for checking and fixing of street light fittings/security light fittings of any description on poles / on walls / on pillars etc i.e. in any position at site.(iii)Required screws, insulating tapes, wire, gaskets and other minor items excluding the required spare parts for repairing and making the street light fittings/security light fittings in serviceable condition, will be arranged & supplied by the contractor and cost of which is deemed to be included in the rates quoted by the contractor in above respective item. (iv)Contractor shall be paid only one time the labour charges quoted above in Schedule `A items for a particular fitting repaired irrespective of the number of times labour and resources arranged by him to check the serviceability of the fittings and replacement of unserviceable/ defective parts in order to maintain the fitting in serviceable/working condition.(v) Contractor’s quoted rates for Schedule `A item No 1 is deemed to include for inspection/checking the serviceability of the fittings in position or by taking down as per site requirement, removing the damaged unserviceable / broken parts, fixing the new parts as required, fixing the fittings in same position or the other, connecting the fittings with electric source and testing of fittings as directed. (vi) The accredit rep of Contractor shall daily report to JE E/M and receive the complaints and job card of U/S street lights on each working day and detail his electirician for repair/rectification and make the street lights in serciceable condition. (vii) If his rep fails to report concerned JE,a panelty @ Rs. 500/- per day shall be recovered.The US/defective each street lights shall be got repaired and make functional within two days from the issue of job card, failing to which Rs. 50/- per light per day shall be recovered from the contractor as penalty.(viii) All security equipments will be provided by the contractor to the workers with out no extra cost. In case of any accident contractor will be responsible to give necessary medical aids and also compensation to the worker under compensation act 1923. 3 Supply only the following parts for LEDfittings:- 4 (a) Driver for street light 45 Watts Make : Wipro/Havells/Crompton Greaves/ Bajaj. 5 (b) Driver for street light 70 Watts Make : Wipro/Havells/Crompton Greaves/ Bajaj. 6 (c) Driver for street light 90 Watts Make : Wipro/Havells/Crompton Greaves/ Bajaj. 7 (d) Driver for flood light 100 Watts Make : Wipro/Havells/Crompton Greaves/ Bajaj. 8 (e) Driver for flood light 120 Watts Make : Wipro/Havells/Crompton Greaves/ Bajaj. 9 Disconnecting and Taking out U/S street light fittings any type, ( LED street light, LED flood lights, HPSV and MH lights) and fixing only street light fittings/security light fittings of any type and in any position on poles/walls/ pillars etc. including cleaning the acrylic cover, connecting the fittings with electric source with using suitable PVC insulated and sheathed flexible solid 2 core 2.5 Sqmm size copper/Aluminium conductor cable with testing of fittings complete all as specified and directed. Note: Old serviceable Security light fittings/Street light fittings shall be used under this item. 10 S&F Energy saving, environmental friendly, long life , Exlusive innovative die -cast aluminium IP66flood light luminair with high powerLED as light source 250 W LED 6000K with1.5 sqmm 3 core copper conductor cable complete including dismantling and taking down old unserviceable street ligt/flood ligh fitting any type/size/capacity and specification complete all as specified and directed by Engineer-in-Charge. 11 S&F Energy saving, environmental friendly, long life , Exlusive innovative die -cast aluminium IP66flood light luminair with high powerLED as light source 100 W LED 6000K with1.5 sqmm 3 core copper conductor cablecompleteincluding dismantling and taking down old unserviceable street ligt/flood ligh fitting any type/size/capacity and specification completeall as specified and directed by Engineer-in-Charge. 12 S&F Energy saving, environmental friendly, long life , Exlusive innovative die -cast aluminium IP65flood light luminair with high powerLED as light source 70 W LED 4000K with1.5 sqmm 3 core copper conductor cable completeincluding dismantling and taking down old unserviceable street ligt/flood ligh fitting any type/size/capacity and specification completeall as specified and directed by Engineer-in-Charge. 13 S&F Energy saving, environmental friendly, long life , Exlusive innovative die -cast aluminium IP66Street light luminair with high powerLED as light source 45 W LED 4000K with1.5 sqmm 3 core copper conductor cable complete including dismantling and taking down old unserviceable street ligt/flood ligh fitting any type/size/capacity and specification complete all as specified and directed by Engineer-in-Charge. 14 S&F Energy saving, environmental friendly, long life , Exlusive innovative die -cast aluminium IP66Street light luminair with high powerLED as light source 120 W LED 4000K with1.5 sqmm 3 core copper conductor cable completeincluding dismantling and taking down old unserviceable street ligt/flood ligh fitting any type/size/capacity and specification completeall as specified and directed by Engineer-in-Charge. 15 S&F Energy saving, environmental friendly, long life , Exlusive innovative die -cast aluminium IP66Street light luminair with high powerLED as light source 90 W LED 4000K with1.5 sqmm 3 core copper conductor cable completeincluding dismantling and taking down old unserviceable street ligt/flood ligh fitting any type/size/capacity and specification complete all as specified and directed by Engineer-in-Charge. 16 S&F Energy saving, environmental friendly, long life , Exlusive innovative die -cast aluminium IP66Street light luminair with high powerLED as light source 70 W LED 4000K with1.5 sqmm 3 core copper conductor cable completeincluding dismantling and taking down old unserviceable street ligt/flood ligh fitting any type/size/capacity and specification complete all as specified and directed by Engineer-in-Charge. 17 Dimantling and Taking out old U/S time switch any typeand in replacement S & F in Automatic street light Switch for automatic switching OFF street lightat 30 Lux level and switching ON at 10 Lux of natural light the sensor along with suitable power Contactors of rating 63 Amps 3 Phase, MCB 63 Amps-03 Nos should be enclosed in pole/wall mountable enclosure made of Rust proof, Electric shock proof, Termite proof and FR grade conforming to IP55. The contactors, MCBs and circuit wiring shouldsuitable enough to take load of 25 KW equially distribution over three phase 415 Volts A/Call as specified and directed. 18 Dismantling and Taking out old unserviceable time switch any type and supply and fixing in replacement of Single phase Timer switch set consisting of Nature Switch-02, MCB of 63 Amps and contactor of 40 Amps all housed in a pole mountable enclosure made of UV stabilize, FR grade,special moulding compound to provide a rust proof, electric shock proof, termite proof, outdoor type electrically insulating boady capable of enduring solar radiation in the out door with selectable options for duration based switching OFF as well override facility for maintenance with featuresautomatic switch on at dusk, aotomatic switch off at dawn, wide operating voltage range 150-280 V AC, load rating of minimum 8 KW Over and low voltage sense, trip and auto reset, Switching off selection from 4-8 hrs with 1/2 hour increments, Overload trip complete including all accessories to fix on pole such as suitable clamps, nuts, bolts and washers etc all as specified and directed by Engineer -in-Charge. 19 Supply & Fixing Power Contactors CX3 65, 65 Amps, 3 Pole Integrated auxiliary contacts 2 NO + 2 NC Screw terminals Conform toIEC/EN 61095including busbar of 65 A - 4 Nos all as spesified and directed. 20 Supply & Fixing Power Contactors CX3 100, 100 Amps, 3 Pole Integrated auxiliary contacts 2 NO + 2 NC Screw terminals Conform toIEC/EN 61095including busbar of 100 A - 4 Nos all as spesified and directed. 21 Supply & Fixing Power Contactors CX3 150, 150 Amps, 3 Pole Integrated auxiliary contacts 2 NO + 2 NC Screw terminals Conform toIEC/EN 61095including busbar of 150 A - 4 Nos all as spesified annd directed. 22 Dismantling and taking out old unserviceable existingU/S Changeover switch any type, Supply and connected Euroload Four Pole 160 Amp 415 Volt 50 HZ Changeover with Advance Neutral, Open Execution conforming to IS 13947 (part-3);IEC:60947-3 all as spesified and directed. 23 Dismantling and taking out old unserviceable existingU/S Changeover switch any type, Supply and connected Euroload Four Pole 250 Amp 415 Volt 50 HZ Changeover with Advance Neutral, Open Execution conforming to IS 13947 (part-3); IEC:60947-3 all as spesified and directed. 24 Supply & fixing in repair Isolator TPN, 63 Amps having current rating 10 KA complete all as specified and directed. 25 Supply, fixing, testing and commissioningin repairs MCCB, 100 Amps, 4 pole, 415 Volts, AC supply,having breaking capacity Icu = Ics, Icu =16 KA with adjustable load setting. 26 Supplying & fixing in replacement new PVC insulated, served with inner sheathed pvc tape weatherproof stranded Alumunium conductor cable twin core 2.5 Sqmm size for connecting from Over head conductor to street light fittings with connector etc complete all as specified and directed by Engineer-in-Charge. 27 - ditto- but of size 10 Sqmm twin core. 28 - ditto- but of size 6 Sqmm twin core. 29 Disconnecting and taking out existing MS/PVC/Fibre boxes of any type and in any position on poles or fixed in the plinth and supplying and fixing in position new PVC (Sinthetic) boxes of size 280mm X 170mm X 115mm depth, made out with Sinthetic.The box shall be provided with and including 10 cm long aluminium bus bar of size 20x3 mm size 2 Nos mounted on porcelain insulators including one No. MCB SP of ‘C’ series, 5/6 Amps of Make Legrand/schneider/GEand connecting the bus bars to cables withusing suitable GI nut, bolts and washers and aluminum lugs etc fixed on pole using 30x5 mm GI clamps, nuts, bolts & washers etc complete all as specified and directed by Engineer-in-Charge. Note :-The contractors quoted rates for the above items are deemed to include for fixing the Sinthetic box in position with suitable MS clamps all as specified and directed by the Engineer-in-Charge. 30 Disconnecting, taking out and removing old existing unserviceable underground, LT cable of any description and in any position complete including taking down unserviceable protection pipe, earth work to take out the loop where requiredetc, stacking the cables properly for reuse, the quoted rates shall be deemed to include cutting out the defective portion of cables and its removal from site all as specified and directed by the Engineer-in-Charge for the following sizes from ducts/ trenches / poles /pipes etc :- 31 LT aluminium conductor cable of size up to 10 to 16 Sqmm, 2 to 4core 32 LT aluminium conductor cable of size up to25to 50 Sqmm, 3 ½core 33 Laying, jointing and testing XLPE / P.V.C., LT Cable PVC insulated, armoured, heavy duty electric cable with aluminium conductor 1100 volts grade of any description and any make laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed by the Engineer-in-charge for the following sizes :- Note :- (i) Obtained from item No 25.01 & 25.02 above and will be laied after requisite repairs and jointing etc.(ii) Repairs/joint will be measured and paid separately under respective items of schedule. 34 LT aluminium conductor cable of size up to 10 to 16 Sqmm, 2 to 4core 35 LT aluminium conductor cable of size up to25to 50 Sqmm, 3 ½core 36 Supply, laying, jointing and testing XLPE insulated, armoured, heavy duty, aluminium conductor cable 1100 volts grade laid in trenches/ducts, floors, fixed to walls etc complete all as specified and directed by the Engineer-in-charge for the following sizes: 37 10 Sqmm2core 38 16 Sqmm4core 39 25 Sqmm 4 core 40 50 Sqmm 3.5 core 41 Supply, Fixing, jointing and testing for provision of straight through joints, epoxy type with epoxy jointing materials, suitable for XLPE, LT Cable, 1100 Volts grade, for the following sizes of cablesall as specified and directed by the Engineer-in-Charge. 42 (a)10 Sqmm to 16 Sqmm any core. 43 (b)25 Sqmm to 70 Sqmm3½core. 44 S&F for cable jointing kitin repairs for 1.1 KV grade cable for end termination heat shrinkable type joints with jointing material and accessories suitable for 4 core 16sqmmXLPE insulated armoured aluminium conductor cable complete all as specified directed by Engr-in-Charge. 45 S&F for cable jointing kitin repairs for 1.1 KV grade cable for end termination heat shrinkable type joints with jointing material and accessories suitable for 3.5 core 25 to 50 sqmmXLPE insulated armoured aluminium conductor cable complete all as specified directed by Engr-in-Charge. 46 Disconnecting existing LT over heated or burnt cable terminal Joints at existing panel/ board/feeder pillar box /overhead lines etc, cutting out over heated / burnt / unserviceable end portion of cable, stretching/ opening cable to suitable required length from available rings/loop including necessary excavation if required etc and fixing and connecting the cable in position properly by providing suitable new aluminium lugs and suitable GI nuts, bolts & washers and end joint etc complete all as specified and directed by the Engineer-in-charge for the following sizes:- Note :- (i) Cable joint will be measured and paid separately under respective items of schedule. 47 (a) LT aluminium conductor cable of size 10 to 25 Sqmm of any core 48 (b) LT aluminium conductor cable of size 35 to 70 Sqmm of any core 49 Excavation in trenches in soft & loose soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient forlaying cables/pipes etc.all as specified and directed by Engineer-in-Charge including removing cable protection PCC covers/ bricks & stacking serviceable covers / bricks for reuse and disposal of unserviceable covers within 50 m all as directed. Note : Excavation shall be made carefully in order to avoid damage of existing cables and protection covers. 50 Returning, filling in including spreading, leveling, watering and well ramming in layers of25 cm thickafter the cables etc. are laid, jointed & tested complete all as specified and directed by Engineer-in-Charge. 51 Removal of surplus excavated spoil not exceeding 50 Mtr distance and depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 m above the starting point complete all as specified. 52 M&L for dry and clean fine sand for cablecushioning to under ground cable protection, complete all as specified. Note-Punned thickness shall be measured & paid. 53 M&L bricks for coverunderground cable with one layer of bricks using sub class B bricks (Old size) laid flat across the cable complete all as specified. 54 Laying only old retrieved serviceable bricks for cable protection with axis of the bricks perpendicular to the axis of the cable of any description as obtained from dismantling of the cable complete all as specified and directed by the Engineer-in-Charge. 55 Trimming/cutting of all trees branches and cleaning of buses upto 3.0 mtr distance both side from nearest conductor/ Earth Wire at LT overhead line including cleaning of site anddepositing of material upto 250 mtr distance at site all as specified and directed by Engineer - in - Charge. 56 Supply and Fixing LED lamp 5 watt.Make:- Havells / Crompton/ Bajaj. 57 Supply and Fixing LED lamp 9 watt.Make:- Havells / Crompton/ Bajaj. 58 Supply and Fixing LED lamp 15 watt.Make:- Havells / Crompton/ Bajaj. 59 Supply and Fixing lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings. 60 Supply, fixing, connecting & testing in repair sheet metal enclosures double pole, 2 way DBs for using MCBs/ MCB isolators without bus bar all as specified & directed by Engineer - in- charge. 61 S&F MCB single pole & Neutral 63 Amps, 10 KA, 240 Volts, complete all as specified and directed. 62 S&F MCB single pole 6 to 32 Amps, 10 KA, 240 Volts complete all as specified and directed. 63 Dismantling and taking down existing serviceable/unserviceable/ de-shaped/worn out LT/HT steel tubular / PCC pole of any shape, size & height including demolition of existing PCC foundation complete all as specified and directed. 64 Supply and erecting steel tubular swaged pole (410 SP-31)9 mtr long, complete with cast iron base plate, pole cap / finial taper plug, bolts, nuts and washers, welded reduced section and longitudinal weld throughout entire length of pole complete all as specified and dircetd. Make:- Jindal Steel Products /Bombay Tubes and Poles /National Tubing Co. /BCW. 65 S&F LED outdoor beam throw focus spot light, LED light source 10 W having the distance length of attraction upto 25 meter warm white made out of presure casting and aluminium, input voltage 85-265 volt AC reflector efficency 95%.complete all as specified and as directed. 66 Supply and fixing LED tunder water light for fountain LED capacity of 10 w, incandascent lighting type completeall as specified and directed by Engineer - in - Charge. 67 Supply and fixing marathon ultra yellow reope light warm white, 120 LED per meter, IP-65 water proof completeall as specified and directed by Engineer - in - Charge. 68 M&L for PCC (1:3:6 ) type C-2 ( using 40 mm graded stone aggregates ) as in sub base foundation etc. complete all as specified and directed. 69 M&L for PCC (1:2:4 ) type B-1 with20 mm graded stone aggregates for coping of poles with all necessary form work complete all as specified and directed. 70 M&L for PCC (1:4:8 ) type D-2 with40 mm graded stone aggregates for foundation of pole of complete allas specified and directed. 71 Dismantling and Taking out old us GI pipe bracket and Supplying, laying & jointing GI tubing bracket 40 mm bore, light grade as in sleeving etc for bracket 1.2 M length and as per site requirment as specified and directed by Engineer-in-Charge. 72 Dismaintling ofU/S garden light and Supplying, fixing, connecting and testing the outdoor and garden lights 8 watt pressure die cast powder coated housing with PC diffuser, efficient high output LED with IP 65 protection all as specified & directed by Engineer-in-Charge. Make : Havells /Crompton Greaves /Bajaj/Philips. 73 Dismaintling ofU/S garden light and Supplying, fixing, connecting and testing the outdoor and garden lights 20 Wattpressure die cast powder coated housing with PC diffuser, efficient high outputwith IP 65 protection all as specified & directed by Engineer-in-Charge. Make : Crompton Greaves/ Havells/Bajaj/Philips. 74 Dismaintling ofU/S gate light and Supplying, fixing, connecting and testing the IP 65 LED post-top family, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source. Opal Cover offers soothing uniform illumination for different applications 70 Watt .all as specified & directed by Engineer-in-Charge.Make :-Havells Crompton Greaves /Philips /Bajaj. 75 Dismantling and taking out the old burnt out ACSR conductor includingremoving binding wire from insulators/jumpers and keeping a side for further disposal in accordance of direction of Engr-in-Charge. 76 Supply and fix LT OH lines on existing poles with ACSR conductors of size 3 of 6/1 x 3.00 mm (Ferret),1 of 6/1 x 2.59 mm (Weasel)
Disclaimer
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tender Detail
| Website | https://prasarbharati.gov.in/pbtenders/ |
| Quantity | |
| MSME Exemption | No |
| Tender Type | Open Tender |
| Startup Exemption | Click Here |
| Competitive Bidding | NCB |
TENDER INSIGHTS
858
Electric TendersLive
Tell us about your Product / Services,
We will Find Tenders for you