TDR : 43012080
Prasar Bharati

Tender Brief :

Bareilly, Uttar Pradesh

Tender For Renovation Of G.F Gents Toilet, Providing Vitrified Tile Flooring In Dde Room And Repair Of Sunken Path Near Boring For Akashvani At Bareilly (Up)

Published: 19 Mar 2024
Opening: 26 Mar 2024
Closing: 26 Mar 2024
Amount: 1.90 Lakhs
EMD: 3807
Tender Fee: Ref. Documents


Works Track Work Iron removal Plant Drainage Construction Material Water Supply
0
Days Left
Tender Summary / Eligibility Criteria
Tender For Renovation Of G.F Gents Toilet, Providing Vitrified Tile Flooring In Dde Room And Repair Of Sunken Path Near Boring For Akashvani At Bareilly (Up)
Documents Download All
46d8824d-6a3e-407b-ab0e-b898186c9668
46d8824d-6a3e-407b-ab0e-b898186c9668.rar
No Boq
No Corrigendum
Probable Bidders

AI engine predicts probable bidders to help you bid strategically.

MSME Exception
Explore More →
Technical
Tender involves procurement of high capacity electrical equipment including diaphragm coupling of pump & motor with 90kW capacity at 2900 RPM. The project scope includes installation, testing, commissioning and operational handover.
Previous / Similar Result
BRR : 9171938 Repair And Renovation Work For Rashtriya Raksha University, Transit Campus At Dr. Smnru University, Lucknow Repair And Renovation Work For Rashtriya Raksha University, Transit Campus At Dr. Smnru University, Lucknow , Dismantling Old Plaster Or Skirting Raking Out Joints And Cleaning The Surface For Plaster Including Disposal Of Rubbish To The Dumping Ground Within 50 Metres Lead , Demolishing R.C.C. Work Manually / By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer - In- Charge , Demolishing Brick Work Manually / By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge.In Cement Mortar , Demolishing Rb Work Manually / By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge.In Cement Mortar , Dismantling Doors, Windows And Clerestory Windows ( Steel Or Wood ) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead :Of Area Beyond 3 Sq. Metres , Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Metres Lead. For Thickness Of Tiles 10 Mm To 25 Mm , Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means Over Areas ( Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan ) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5 M, As Directed By Engineer-Incharge. , 1:4:8 ( 1 Cement : 4 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 8 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources ) , Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Beam : , Same As Item No 5 Above , 1:1.5:3 ( 1 Cement : 1.5 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) ( Foundation ) , Same As Item No 5 Above , 1:1.5:3 ( 1 Cement : 1.5 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) ( Column ) , Reinforced Cement Concrete Work In Walls ( Any Thickness ) , Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : 1:1.5:3 ( 1 Cement : 1.5 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) , Steel Reinforcement For R.C.C. Work Including Traightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level. Mild Steel And Medium Tensile Steel Bars , Brick Work With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 In Foundation Below Plinth Level Up To Floor V Level In All Shapes And Sizes In : Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) , Brick Work With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level In All Shapes And Sizes In : Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) , Half Brick Masonry With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. Cement Mortar 1:4 ( 1 Cement :4 Coarse Sand ) , Supplying And Filling In Plinth With Sand Under Floors, Including Watering, Ramming, Consolidating And Dressing Complete. , Diluting And Injecting Chemical Emulsion For Post-Constructional Anti-Termite Treatment ( Excluding The Cost Of Chemical Emulsion ) : Treatment Of Soil Under Existing Floors Using Chemical Emulsion @ One Litre Per Hole, 300 Mm Apart Including Drilling 12 Mm Diameter Holes And Plugging With Cement Mortar 1 :2 ( 1 Cement : 2 Coarse Sand ) To Match The Existing Floor:With Chlorpyriphos / Lindane E.C. 20% With 1% Concentration , Kota Stone Slab Flooring Over 20 Mm ( Average ) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab, Including Rubbing And Polishing Complete With Base Of Cement Mortar 1 : 4 ( 1 Cement : 4 Coarse Sand ) : 25 Mm Thick , Kota Stone Slabs 20 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm ( Average ) Thick Cement Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete. , Steel Work In Built Up Tubular ( Round, Square Or Rectangular Hollow Tubes Etc. ) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. Hot Finished Seamless Type Tubes , Providing Corrugated G.S. Sheet Roofing Including Vertical / Curved Surface Fixed With Polymer Coated J Or L Hooks, Bolts And Nuts 8 Mm Diameter With Bitumen And G.I. Limpet Washers Or With G.I. Limpet Washers Filled With White Lead, Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete ( Up To Any Pitch In Horizontal / Vertical Or Curved Surfaces ) , Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 0.80 Mm Thick With Zinc Coating Not Less Than 275 Gm / M² , Providing Ridges Or Hips Of Width 60 Cm Overall Width Plain G.S. Sheet Fixed With Polymer Coated J Or L Hooks, Bolts And Nuts 8 Mm Dia G.I. Limpet And Bitumen Washers Complete. 0.80 Mm Thick With Zinc Coating Not Less Than 275 Gm / M² , Providing And Fixing 15 Cm Wide, 45 Cm Overall Semi-Circular Plain G.S. Sheet Gutter With Iron Brackets 40X3mm Size, Bolts, Nuts And Washers Etc., Including Making Necessary Connections With Rain Water Pipes Complete. 0.80 Mm Thick With Zinc Coating Not Less Than 275 Gm / M² , Providing And Fixing Isi Marked Flush Door Shutters Conforming To Is : 2202 ( Part I ) Decorative Type, Core Of Block Board Construction With Frame Of 1St Class Hard Wood And Well Matched Teak 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters 35 Mm Thick Including Isi Marked Stainless Steel Butt Hinges With Necessary Screws , M.S.Work In D / W Hold Fast , M.S.Work In D / W M.S.Grill , Z-Section Windows , Providing And Fixing Angle Iron Frames For Doors Of Mild Steel Angle Sections , 15 Mm Cement Plaster Of Mix : 1:6 ( 1 Cement: 6 Coarse Sand ) , 12 Mm Cement Plaster Of Mix : 1:6 ( 1 Cement: 6 Coarse Sand ) , 12 Mm Cement Plaster Of Mix : 1:6 ( 1 Cement: 6 Coarse Sand ) , Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade : New Work ( Two Or More Coats ) Over And Including Water Thinnable Priming Coat With Cement Primer , Finishing Walls With Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade New Work ( Two Or More Coats Applied @ 1.43 Ltr / 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg / 10 Sqm ) , ( D ) Finishing The Surface With 20 Mm Thick Jointless Cement Mortar Of Mix 1:4 ( 1 Cement :4 Coarse Sand ) Admixed With Water Proofing Compound Conforming To Is : 2645 And Approved By Engineer-In-Charge Including Laying Glass Fibre Cloth Of Approved Quality In Top Layer Of Plaster And Finally Finishing The Surface With Trowel With Neat Cement Slurry And Making Pattern Of 300X300 Mm Square 3 Mm Deep. ( E ) The Whole Terrace So Finished Shall Be Flooded With Water For A Minimum Period Of Two Weeks For Curing And For Final Test.“All Above Operations To Be Done In Order And As Directed And Specified By The Engineer-In-Charge : 22.7.1 With Average Thickness Of 120 Mm And Minimum Thickness At Khurra As 65 Mm. , With Ready Mixed Red Oxide Zinc Chromate Primer Of Approved Brand And Manufacture On Steel Galvanised Iron / Steel Works , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work , With Ready Mixed Pink Or Grey Primer Of Approved Brand And Manufacture On Wood Work ( Hard And Soft Wood ) , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work , Providing & Fixing Glass Panes With Putty And Glazing Clips In Steel Doors, Windows, Clerestory Windows, All Complete With : 4.0 Mm Thick Glass Panes , Providing And Laying Vitrified Floor Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Jointing With Grey Cement Slurry @ 3.3 Kg / Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600X600 Mm , Providing And Laying Vitrified Tiles In Different Sizes ( Thickness To Be Specified By Manufacturer ) , With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) , Jointing With Grey Cement Slurry @ 3.3 Kg / Sqm Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete. Size Of Tile 600X600 Mm , Providing And Laying Rectified Glazed Ceramic Floor Tiles Of Size 300X300 Mm Or More ( Thickness To Be Specified By The Manufacturer ) , Of 1St Quality Conforming To Is : 15622, Of Approved Make, In All Colours, Shades, Except White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Jointing With Grey Cement Slurry @ 3.3 Kg / Sqm Including Pointing The Joints With White Cement And Matching Pigments Etc., Complete. , Design Supply & Installation Of Suspended Spider Glazing System Designed To Withstand The Wind Pressure As Per Is 875 ( Part-Iii ) . The Suspended System Held With Spider Fittings Of Ss-316 Grade Steel Of Approved Manufacturer With Glass Panel Having 12 Mm Thick Clear Toughened Glass Held Together With Ss- 316 Grade Stainless Steel Spider & Bolt Assembly With Laminated Glass Fins 21 Mm Thick. The Glass Fins And Glass Panel Assembly Shall Be Connected To Slab / Beams By Means Of Ss- 316 Grade Stainless Steel Brackets & Anchor Bolts And At The Bottom Using Ss Channel Of 50X25x2mm Using Fastener & Anchor Bolts, Non Staining Weather Sealants Of Approved Make, Teflon / Nylon Bushes And Separators To Prevent Bi-Metallic Contacts, All Complete To Perform As Per Specification And Approved Drawings. The Complete System To Be Designed To Accommodate Thermal Expansion & Seismic Movements Etc. The Joints Between Glass Panels ( 6 To 8 Mm ) And Gaps At The Perimeter & In U Channel Of The Assembly To Be Filled With Non Staining Weather Sealant, So As To Make The Entire System Fully Water Proof & Dust Proof. The Rate Shall Include All Design, Engineering And Shop Drawing Including Approval From Structural Designer, Labour, T&P, Scaffolding, Other Incidental Charges Including Wastage, Enabling Temporary Services All Fitting Fixers Nut Bolts, Washer, Buffer Plates, Fastener, Anchors, Ss Channel Laminated Glass Etc. All Complete. For The Purpose Of Payment, Actual Elevation Area Of Glazing Including Thickness Of Joints And The Portion Of Glass Panel Inside The Ss Channel Shall Be Measured. , Steel Work In Built Up Tubular ( Round, Square Or Rectangular Hollow Tubes Etc. ) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. , P / F Curtain Rods Of 1.25Mm Thick Chromium Plated Brass Plate, With Two Chromium Plated Brass Brackets Fixed With C.P. Brass Screws And Wooden Plugs Etc. Wherever Necessary Complete ( A ) 25 Mm Dia. , Providing & Fixing Fly Proof Wire Gauze To Windows, Clerestory Windows & Doors With M.S. Flat 15X3 Mm And Nuts & Boltscomplete.Stainless Steel ( Grade 304 ) Wire Gauze Of 0.5 Mm Dia Wire And 1.4 Mm Aperture On Both Sides. , Providing And Fixing False Ceiling At All Heights With Integral Densified Calcium Silicate Reinforced With Fibre And Natural Filler False Ceiling Tiles Of Size 595X595 Mm Of Approved Texture, Design And Patterns Having Nrc ( Noise Reduction Coefficient ) Of 0.50 ( Minimum ) As Per Is 8225:1987, Light Reflectance Of 85% ( Minimum ) . Non Combustible As Per Bs:476 ( Part-4 ) , Fire Performance As Per Bs:476 ( Part 6 &7 ) , Humidity Resistance Of 100%, Thermal Conductivity < 0.043 W / M K As Per Astm 518:1991, In True Horizontal Level Suspended On Interlocking Metal Powder Coated T-Grid Of Hot Dipped Galvanised Iron Section Of 0.40 Mm Thick On Silhouette Profile, Rotary Stiched Double Webbed White With 6Mm Reveal Profile ( White / Black ) , Comprising Of Main-T Runners Of Size 15X42mm Of Length 3000 Mm, Cross - T Of Size 15X42 Mm Of Length 1200 Mm And Secondary Intermediate Cross- T Of Size 15X42 Mm Of Length 600Mm To Form Grid Module Of Size 600 X 600 Mm, Suspended From Ceiling Using Galvanised Mild Steel Items ( Galvanizing @ 80 Grams Per Sqm ) I.E. 50 Mm Long, 8 Mm Outer Diameter M-6 Dash Fasteners, 6 Mm Dia Fully Threaded Hanger Rod Upto 1000 Mm Length And L-Shape Level Adjuster Of Size 85X25x2 Mm. Galvanised Iron Perimeter Wall Angle Of Size 22X19x0.40 Mm Of Length 3000 Mm To Be Fixed On Periphery Wall / Partition With The Help Of Plastic Rawl Plugs At 450 Mm Center To Center And 40Mm Long Dry Wall S.S Screws. The Work Shall Be Carried Out As Per Specifications, Drawing And As Per Directions Of The Engineer-In-Charge. With 15 Mm Thick Integral Densified Micro Edge Light Weight Calcium Silicate False Ceiling Tiles , Applying Priming Coat: With Ready Mixed Red Oxide Zinc Chromate Primer Of Approved Brand And Manufacture On Steel Galvanised Iron / Steel Works , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work , Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is:13592 Type A, Including Jointingwithsealringconformingtois: 5382, Leaving 10 Mm Gap For Thermal Expansion. Single Push Fit Coupler110 Mm Dia , Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is:13592 Type A, Including Jointingwithsealringconformingtois: 5382, Leaving 10 Mm Gap For Thermal Expansion.Shoe ( Plain ) 110 Mm Shoe , Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is:13592 Type A, Including Jointingwithsealringconformingtois: 5382, Leaving 10 Mm Gap For Thermal Expansion. Plain Bend 87.5 Deg 110 Mm Dia , Providing And Fixing Unplasticised -Pvc Pipe Clips Of Approved Design To Unplasticised - Pvc Rain Water Pipes By Means Of 50X50x50 Mm Hard Wood Plugs, Screwed With M.S. Screws Of Required Length, Including Cutting Brick Work And Fixing In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) And Making Good The Wall Etc. Complete. 110 Mm , Fixing Of Door Chaukhats , Providing & Fixing Stainless Steel Sliding Door Bolts Isi Marked Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade With Nuts And Screws Etc Complete. ( A ) 250Mm X 16Mm . , Providing And Fixing Stainless Steel Towerbolts ( Barrel Type ) With Necessary Screws Etc. Complete ( A ) 300 Mm X 10Mm , Providing And Fixing Stainless Steel Handles With Screws Etc. Complete ( A ) 125 Mm , Providing & Supplying Curtains. , Cc Flooring With 1:2:4 With 40 Mm Thick , Cement Plaster Up 30 Cm Heght With 1:3 Cement Sand Morter , Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion, ( I ) Single Socketed Pipes. 110 Mm Diameter , Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Piano Type Switch, Phenolic Laminated Sheet, Suitable Size M.S. Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. , Wiring For Light / Power Plug With 2X4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit Alongwith 1 No. 4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. , Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required. 4 X 10 Sq. Mm + 2 X 6 Sq. Mm Earth Wire , Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required.2 X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire , Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required. 4 X 16 Sq. Mm + 2 X 6 Sq. Mm Earth Wire , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 15 / 16 A Socket Outlet 3 Pin 5 / 6 A Socket Outlet , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 15 / 16 A Socket Outlet 15 / 16 A Socket Outlet , Installation, Testing And Commissioning Of Ceiling Fan, Including Wiring The Down Rods Of Standard Length ( Upto 30 Cm ) With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable, Including Providing And Fixing Phenolic Laminated Sheet Cover On The Fan Box Etc. As Required. , Installation Of Exhaust Fan In The Existing Opening, Including Making Good The Damage, Connection, Testing, Commissioning Etc. As Required. Upto 450 Mm Sweep , Providing And Fixing Circular / Hexagonal G.I. Box For Ceiling Fan Clamp, Of Internal Dia 140 Mm, 73 Mm Height, Top Lid Of 1.5 Mm Thick G.I. Sheet With Its Top Surface Hacked For Proper Bonding, Top Lid Shall Be Screwed Into The G.I. Box By Means Of 3.3 Mm Dia Round Headed Screws, One Lock At The Corners. Clamp Shall Be Made Of 12 Mm Dia M.S. Bar Bent To Shape As Per Standard Drawing. ( Dsr Civil-2014 Item No. 10.18 ) , Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. , Supply And Fixing Of1x22 Watt Led Tube Light ( Surface ) Complete In All Respect. , Supply And Fixing Of36-46 Watt Recess Mounting Led Square Light Complete In All Respect. , Supply And Fixing Of15w-18W Led Down Lighter Complete In All Respect. , Supply And Fixing Of 17 Watt Led Mirror Light And Complete In All Respect. , Supply And Fixing Of10w-15W Led Cealing Light Complete In All Respect. , Supply And Fixing Ofwall Mounted Light Fixture Complete In All Respect. , Supply And Erection Of Ac 230 / 250 Volts, 50 Hz Exhaust Fans Including Providing Nuts, Bolts, Mounting Frame And Other Accessories Including Connections Etc. Complete As Required.300Mm Sweep. , Supply And Erection Of Ac 1200Mm Sweep, 230 / 250 Volts, 50 Hz Ceilling Fan With Down Rod, Blades Including Connection Etc. Complete As Required , Supplying And Fixing Following Way, Horizontal Type Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 6 Way ( 4 + 18 ) , Double Door , Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. , Supplying And Fixing Following Rating, Double Pole, ( Single Phase And Neutral ) , 240 V, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40 A , Supplying And Fixing Following Rating, Double Pole, ( Single Phase And Neutral ) , 240 V, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 63 A , S&F Of 100 A, 16 Ka, Tpmccb Mccbthermal Magnetic Release , S&F Of 125 A, 16 Ka, Tpmccb Mccbthermal Magnetic Release , Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. ( But Without Charcoal / Coke And Salt ) As Required. , Supplying And Laying 25 Mm X 5 Mm G.I Strip At 0.50 Metre Below Ground As Strip Earth Electrode, Including Connection / Terminating With G.I. Nut, Bolt, Spring, Washer Etc. As Required. , Providing And Laying Earth Connection From Earth Electrode With 6 Swg Dia G.I. Wire In 15 Mm Dia G.I. Pipe From Earth Electrode Including Connection With G.I. Thimble Excavation And Re-Filling As Required. , Supplying And Fixingfollowing Size / Modules, Gi Box Along With Modular Base& Cover Plate For Modular Switches In Recess Etc As Required. 1 Or 2 Module ( 75Mm X 75 Mm ) , Supplying And Fixing Following Modular Switch / Socket On Theexisting Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc As Required. Telephone Socket Outlet , Supplying And Drawing Telephone Wire Following Pair 0.5 Sqmm Fr Pvc Insulated Annealed Copper Conductor, Unarmoured Telephone Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 2 Pair , Supply And Fixing Of36 Watt Led Hanging Light Complete In All Respect. , Supply And Erection Of Ac 1400Mm Sweep, 230 / 250 Volts, 50 Hz Ceilling Fan With Down Rod, Blades Including Connection Etc. Complete As Required , Supplying And Fixing Extra Conduit Down Rod Of 60 Cm Length G.I. Pipe 15 Mm Dia, Heavy Gauge Including Painting Etc. As Required. , Numbering Of Ceiling Fan / Exhaust Fan / Fluorescent Fittings As Required. , Providing And Fixing Water Closet Squatting Pan ( Indian Type W.C. Pan ) With 100 Mm Sand Cast Iron P Or S Trap, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device ( Handle Lever ) Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required: White Vitreous China Orissa Pattern W.C. Pan Of Size 580X440 Mm With Integral Type Foot Rests , Providing And Fixing White Vitreous China Pedestal Type Water Closet ( European Type W.C. Pan ) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device ( Handle Lever ) , Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required : W.C. Pan With Isi Marked White Solid Plastic Seat And Lid , Providing & Fixing Toilet Paper Holder C.P. Brass , Providing And Fixing 8 Mm Dia C.P. / S.S. Jet With Flexible Tube Upto 1 Metre Long With S.S. Triangular Plate To Eureopean Type W.C. Of Quality And Make As Approved By Engineer - In - Charge. , Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require: White Vitreous China Wash Basin Size 630X450 Mm With A Single 15 Mm C.P. Brass Pillar Tap , Providing And Fixing Cp Brass 32Mm Size Bottle Trap Of Approved Quality & Make And As Per The Direction Of Engineer-In-Charge. , Providing And Fixing Ptmt Towel Ring Trapezoidal Shape 215 Mm Long, 200 Mm Wide With Minimum Distances Of 37 Mm From Wall Face With Concealed Fittings Arrangement Of Approved Quality And Colour, Weighing Not Less Than 88 Gms. , Providing And Fixing Ptmt Soap Dish Holder Having Length Of 138Mm, Breadth 102Mm, Height Of 75Mm With Concealed Fitting Arrangements, Weighing Not Less Than 106 Gms. , Providing And Fixing C.P.Brass Angle Valve For Basin Mixer And Geyser Points Of Approved Quality Conforming To Is 8931 ( Including Angle Valve For Wc Flushing Cistern, Jet & Kitchen Sink ) 15 Mm Nominal Bore , Providing And Fixing Uplasticised Pvc Connection Pipe With Brass Unions :45 Cm Length 15 Mm Nominal Bore , Providing And Fixing Stainless Steel Aisi 304 ( 18 / 8 ) Kitchen Sink As Per Is: 13983 With C.I. Brackets And Stainless Steel Plug 40 Mm, Including Painting Offittings And Brackets, Cuttingandmakinggoodthe Walls Wherever Requiredkitchen Sink With Drain Board 510X1040 Mm Bowl Depth 200 Mm , Providing & Fixing Pvc Waste Pipe For Sink Including Pvc Waste Fittings Complete Flexible Pipe 32Mm Dia , Providing And Fixing 600X450 Mm Beveled Edge Mirror Of Superior Glass ( Of Approved Quality ) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. , Providing And Fixing C.P. Brass Bib Cock Of Approved Quality Conforming To Is:8931 : 15Mm Nominal Bore , Providing And Fixing C.P. Brass Long Body Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 690 Gms. 15Mm Nominal Bore , Providing And Fixing White Vitreous China Battery Based Infrared Sensor Operated Urinal Of Approx. Size 610 X 390 X 370 Mm Having Pre & Post Flushing With Water ( 250 Ml & 500 Ml Consumption ) , Having Water Inlet From Back Side, Including Fixing To Wall With Suitable Brackets All As Per Manufacturers Specification And Direction Of Engineer-In-Charge. , Providing And Fixing Ptmt Bottle Trap For Urinal. Bottle Trap 38 Mm Single Piece Moulded With Height Of 270 Mm, Effective Length Of Tail Pipe 260 Mm From The Centre Of The Waste Coupling, 77 Mm Breadth With 25 Mm Minimum Water Seal, Weighing Not Less Than 263 Gms , Providing And Fixing Stone Slab With Table Rubbed, Edges Rounded And Polished, Of Size 75X50 Cm Deep And 1.8 Cm Thick, Fixed In Urinal Partitions By Cutting A Chase Of Appropriate Width With Chase Cutter And Embedding The Stone In The Chase With Epoxy Grout Or With Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 6 Mm Nominal Size ) As Perdirection Of Engineer-In-Charge And Finished Smooth.Granite Stone Of Approved Shade , Providing And Fixing Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, I / C Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer In Charge.Concealed Work, Including Cutting Chases And Making Good The Walls Etc. 20 Mm Nominal Outer Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, I / C Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer In Charge.Concealed Work, Including Cutting Chases And Making Good The Walls Etc. 25 Mm Nominal Outer Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, I / C Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer In Charge.Concealed Work, Including Cutting Chases And Making Good The Walls Etc. 32 Mm Nominal Outer Dia Pipes , Providing And Fixing Brass Stop Cock Of Approved Quality : 15 Mm Nominal Bore , Providing And Fixing Brass Stop Cock Of Approved Quality : 20 Mm Nominal Bore , Providing And Fixing Gun Metal Gate Valve With C.I. Wheel Of Approved Quality ( Screwed End ) :For Vertical Pipe Connection With Terrace Ringmain 25Mm Nominal Bore , Providing And Fixing Gun Metal Gate Valve With C.I. Wheel Of Approved Quality ( Screwed End ) :For Vertical Pipe Connection With Terrace Ringmain 32Mm Nominal Bore , Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is :13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion, ( I ) Single Socketed Pipes.110 Mm Dia ( For Rain Water ) , Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is:13592 Type A, Including Jointingwithsealringconformingtois: 5382, Leaving 10 Mm Gap For Thermal Expansion. Single Push Fit Coupler 110 Mm Dia , Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is:13592 Type A, Including Jointingwithsealringconformingtois: 5382, Leaving 10 Mm Gap For Thermal Expansion. Single Tee With Door 110X110x110 Mm , Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is:13592 Type A, Including Jointingwithsealringconformingtois: 5382, Leaving 10 Mm Gap For Thermal Expansion.Plain Bend 87.5 Deg 110 Mm Dia , Providing And Fixing Unplasticised -Pvc Pipe Clips Of Approved Design To Unplasticised - Pvc Rain Water Pipes By Means Of 50X50x50 Mm Hard Wood Plugs, Screwed With M.S. Screws Of Required Length, Including Cutting Brick Work And Fixing In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) And Making Good The Wall Etc. Complete.110 Mm Dia , Making Khurras 45X45 Cm With Average Minimum Thickness Of 5 Cm Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate Of 20 Mm Nominal Size ) Over P.V.C. Sheet 1 M X1 M X 400 Micron, Finished With 12 Mm Cement Plaster 1:3 ( 1 Cement : 3 Coarse Sand ) And A Coat Of Neat Cement, Rounding The Edges And Making And Finishing The Outlet Complete. , Providing And Placing On Terrace ( At All Floor Levels ) Polyethylene Water Storage Tank, Is : 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank. , Providing, Fixing, Jointing And Testing, Upvclow Noise Swrhaving Noise Insulation Less Than 10Db At 2Lps Flow Rate Pipeto Wall, Ceiling And Floor, Approved Quality, Complete, For Soil, Waste & Rain Water Drain Including Pushfit Jointing With Seal Ring. ( I ) Single Socketed Pipes. Internal Toilet ( Soil & Waste Pipe ) 75 Mm , Providing, Fixing, Jointing And Testing, Upvclow Noise Swrhaving Noise Insulation Less Than 10Db At 2Lps Flow Rate Pipeto Wall, Ceiling And Floor, Approved Quality, Complete, For Soil, Waste & Rain Water Drain Including Pushfit Jointing With Seal Ring. ( I ) Single Socketed Pipes. Internal Toilet ( Soil & Waste Pipe ) 110 Mm , Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Pipes Including Jointing With Seal Ring Leaving 10 Mm Gap For Thermal Expansion. Bend Without Door ( 87.5° ) 110Mm Bend , Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Pipes Including Jointing With Seal Ring Leaving 10 Mm Gap For Thermal Expansion. Bend Without Door ( 87.5° ) 75Mm Bend , Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Pipes Including Jointing With Seal Ring Leaving 10 Mm Gap For Thermal Expansion. Bend Without Door ( 45° ) 100Mm , Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Pipes Including Jointing With Seal Ring Leaving 10 Mm Gap For Thermal Expansion. Bend Without Door ( 45° ) 75Mm , Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Pipes Including Jointing With Seal Ring Leaving 10 Mm Gap For Thermal Expansion.Single Tee Without Door 110Mm , Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Pipes Including Jointing With Seal Ring Leaving 10 Mm Gap For Thermal Expansion. Single Tee Without Door75 Mm , Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Pipes Including Jointing With Seal Ring Leaving 10 Mm Gap For Thermal Expansion. Coupler 110Mm , Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Pipes Including Jointing With Seal Ring Leaving 10 Mm Gap For Thermal Expansion. Clean Out Plug ( Cop 110Mm , Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Pipes Including Jointing With Seal Ring Leaving 10 Mm Gap For Thermal Expansion. Clean Out Plug ( Cop 75 Mm , Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Pipes Including Jointing With Seal Ring Leaving 10 Mm Gap For Thermal Expansion. Vent Cow L110mm , Providing, Fixing, Jointing And Testing , Oflow Noise Pvc Multi Floor Trap Without Jali Ofminimum 50 Mm Water Seal, Making Necessarycuttingin Slabor Floors And Making Goodincluding Supports With Cement Concrete 1:3:6Complete As Approved By Engineer-In-Charge.110Mm X 75Mm X 50Mm / 40Mm ( Toilet ) , Providing, Fixing, Jointing And Testing , Oflow Noise Pvc Nahanitrap Without Jali Ofminimum 50 Mm Water Seal, Making Necessarycuttingin Slabor Floors And Making Goodincluding Supports With Cement Concrete 1:3:6Complete As Approved By Engineer-In-Charge.110Mm X 75Mm ( Toilet ) , Providing And Fixing Ptmt Grating Of Approved Quality And Colour.Rectangular Type With Openable Circular Lid150 Mm Nominal Size Square 100 Mm Diameter Of The Inner Hinged Round Grating ( Including Balcony ) , Providing And Fixing Square-Mouth S.W. Gully Trap Class Sp-1 Complete With C.I. Grating Brick Masonry Chamber With Water Tight C.I. Cover With Frame Of 300 X300 Mm Size ( Inside ) The Weight Of Cover To Be Not Less Than 4.50 Kg And Frame To Be Not Less Than 2.70 Kg As Per Standard Design :150 X 100Mm Size P-Typewith Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 , Supply And Fixing Of36 Watt Led Hanging Light Complete In All Respect. , Supply And Erection Of Ac 1400Mm Sweep, 230 / 250 Volts, 50 Hz Ceilling Fan With Down Rod, Blades Including Connection Etc. Complete As Required , Supplying And Fixing Extra Conduit Down Rod Of 60 Cm Length G.I. Pipe 15 Mm Dia, Heavy Gauge Including Painting Etc. As Required. , Numbering Of Ceiling Fan / Exhaust Fan / Fluorescent Fittings As Required. , Boring / Drilling Bore Well Of Required Dia For Casing / Strainer Pipe, By Suitable Method Prescribed In Is: 2800 ( Part I ) , Including Collecting Samples From Different Strata, Preparing And Submitting Strata Chart / Bore Log, Including Hire & Running Charges Of All Equipments, Tools, Plants & Machineries Required For The Job, All Complete As Per Direction Of Engineer-In-Charge, Upto 90 Metre Depth Below Ground Level.300Mm Dia 300 Mm Dia , Boring / Drilling Bore Well Of Required Dia For Casing / Strainer Pipe, By Suitable Method Prescribed In Is: 2800 ( Part I ) , Including Collecting Samples From Different Strata, Preparing And Submitting Strata Chart / Bore Log, Including Hire & Running Charges Of All Equipments, Tools, Plants & Machineries Required For The Job, All Complete As Per Direction Of Engineer -In-Harge, Beyond 90 Metre & Upto 150 Metre Depth Below Round Level.300 Mm Dia , Supplying, Assembling, Lowering And Fixing In Vertical Position In Bore Well, Unplasticized Pvc Medium Well Casing ( Cm ) Pipe Of Required Dia, Conforming To Is: 12818, Including Required Hire And Labour Charges, Fittings & Accessories Etc. All Complete, For All Depths, As Per Direction Of Engineer -In-Charge. 150 Mm Nominal Size Dia , Supplying, Assembling, Lowering And Fixing In Vertical Position In Bore Well, Unplasticized Pvc Medium Well Casing ( Cm ) Pipe Of Required Dia, Conforming To Is: 12818, Including Required Hire And Labour Charges, Fittings & Accessories Etc. All Complete, For All Depths, As Per Direction Of Engineer -In-Charge. 200 Mm Nominal Size Dia , Supplying, Assembling, Lowering And Fixing In Vertical Position In Bore Well Unplasticized Pvc Medium Well Screen ( Rms ) Pipes With Ribs, Conforming To Is: 12818, Including Hire & Labour Charges, Fittings &Accessories Etc. All Complete, For All Depths, As Per Direction Of Engineer-In-Charge.150 Mm Nominal Size Dia , Supplying, Filling, Spreading & Leveling Coarse Sand Of Size Range 1.5 Mm To 2 Mm In Recharge Pit, In Required Thickness Over Gravel Layer, For All Leads & Lifts, All Complete As Per Direction Of Engineer -Incharge. 3.14* ( .150*.150-.075*.075 ) *150 , Development Of Tube Well In Accordance With Is : 2800 ( Part I ) And Is:11189, To Establish Maximum Rate Of Usable Water Yield Without Sand Content ( Beyond Permissible Limit ) , With Required Capacity Ai Compressor, Running The Compressor For Required Time Till Well Is Fully Developed, Measuring Yield Of Well By “V” Notch Method Or Any Other Approved Method, Measuring Static Level & Draw Down Etc. By Step Draw Down Method, Collecting Water Samples & Getting Tested In Approved Laboratory, I / C Disinfection Of Tubewell, All Complete, Including Hire & Labour Charges Of Air Compressor, Tools & Accessories Etc., All As Per Requirement And Direction Of Engineer-In-Charge. , Providing And Fixing Suitable Size Threaded Mild Steel Cap Or Spot Welded Plate To The Top Of Bore Wellhousing / Casing Pipe, Removable As Per Requirement, All Complete For Borewell Of:200 Mm Dia , Providing And Fixing M.S. Clamp Of Required Dia To The Top Of Casing / Housing Pipe Of Tubewell As Per Is: 2800 ( Part I ) , Including Necessary Bolts & Nuts Of Required Size Complete.200 Mm Clamp. , Providing And Fixing Bail Plug / Bottom Plug Of Required Dia To The Bottom Of Pipe Assembly Of Tubewell As Per Is:2800 ( Part I ) . 200 Mm Dia. , Supply And Fixing Of Tube Well Pump 10.0 H.P. Cable And Other Necessary All Materils.Ksb Make Or Equvilent , Water Supply Of Tanker 5000 Litre Capacity Of Boring , Supply And Fixing Of Nylon Jali Around The Slotted Pipes Complete As Required Up To 10 Mtr. , Supply Of 80Mm Dia M.S. Column Pipe Of Class C Both And Socketed With Heavy Sockets In 3 / 6 Meter Length And One End Flanged Complete With Interlocking Arrangements. , Supply Of 80Mm Dia M.S. Column Pipe Clamps With Nut Bolts Packing Etc. , Excavating Trenches In All Kinds Ofsoil Of Required Width For Pipes. Including Excavation For Sockets And Dressing Of Sides, Ramming Of Bottoms, Including Getting Out The Excavated Soil & Then Returning The Soil As Required, In Layers Not Exceeding 20 Cm In Depth Including Consolidating Each Deposited Layer By Ramming, Watering, Etc & Disposing Of Surplus Excavated Soil As Directed Within A Lead Of 50M. Up To 1.50 M Depth Pipes 80 Mm To 300 Mmdiameter , Excavating Trenches In All Kinds Ofsoil Of Required Width For Pipes. Including Excavation For Sockets And Dressing Of Sides, Ramming Of Bottoms, Including Getting Out The Excavated Soil & Then Returning The Soil As Required, In Layers Not Exceeding 20 Cm In Depth Including Consolidating Each Deposited Layer By Ramming, Watering, Etc & Disposing Of Surplus Excavated Soil As Directed Within A Lead Of 50M. 1.50 M To 3.00 M Depth Pipes 80 Mm To 300 Mmdiameter , Opentimbering In Trenches Including Shuttering And Shoring Complete. ( Measurement To Be Taken Of The Face Area Timbered ) Depth Not Exceeding 1.5 Meter , Opentimbering In Trenches Including Shuttering And Shoring Complete. ( Measurement To Be Taken Of The Face Area Timbered ) Depth 1.5 To3.00Meter , Providing And Laying Nonpressurenp 2 Class ( Light Duty ) Rcc Pipe With Collars Jointed Withstiffmixtureofcement Mortar In The Proportion Of 1:2 ( 1Cement : 2 Finesand ) Includingtestingof Joints Etc. Complete.150 Mm.Dia. Rccpipes , Providing And Laying Nonpressurenp 2 Class ( Light Duty ) Rcc Pipe With Collars Jointed Withstiffmixtureofcement Mortar In The Proportion Of 1:2 ( 1Cement : 2 Finesand ) Includingtestingof Joints Etc. Complete.250 Mm.Dia. Rccpipes , Providing And Laying Cement Concrete 1:5:10 ( 1 Cement: 5 Coarse Sand : 10 Graded Stone Aggregate 40Mm Nominal Size ) Upto The Haunches Of Pipes Including Bed Concrete As Per Standard Design150 Mm.Dia. Rccpipes , Providing And Laying Cement Concrete 1:5:10 ( 1 Cement: 5 Coarse Sand : 10 Graded Stone Aggregate 40Mm Nominal Size ) Upto The Haunches Of Pipes Including Bed Concrete As Per Standard Design 250 Mm.Dia. Rccpipes , Constructing Brick Masonry Manhole In Cement Mortar 1:4 ( 1 Cement :4 Coarse Sand ) Rcc Top Slab With 1:2:4 Mix ( 1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20Mm Nominal Size ) , Foundation Concrete 1:4:8 Mix ( 1 Cement :4 Coarse Sand :8 Graded Stone Aggregate 40Mm Nominal Size ) Inside Plastering 12Mm Thick With Cement Mortar 1:3 ( 1 Cement :3 Coarse Sand ) Finished With Floating Coat Fo Neat Cement And Making Channels In Cement Concrete 1:2:4 ( 1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20Mm Nminal Size ) Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design. , Inside Size 90X80cms And 45Cms Deep Including Ci Cover With Frame ( Light Duty ) 455X610mm Internal Diamensions Total Weight Of Cover And Frame To Be Not Less Than 38 Kg ( Weight Of Cover 23 Kg And Weight Of Frame 15Kg ) .With Common Burnt Clay Fps ( Non Modular ) Bricks Of Class Designation 75 ( I ) For Sewer Line , Extra For Depth For Manholes:Size 90X80cm With With Common Burnt Clay Fps ( Non Modular ) Bricks Of Class Designation 7.5 , Inside Size 90X120cms And 90Cms Deep Including Ci Cover With Frame ( Medium Duty ) 500 Mm Internal Diameter, Total Weight Of Cover And Frame To Be Not Less Than 116 Kg ( Weight Of Cover 58 Kg And Weight Of Frame 58Kg ) . With Common Burnt Clay Fps ( Non Modular ) Bricks Of Class Designation 75 ( I ) For Sewer Line , Extra For Depth For Manholes: Size 90X120cm With With Common Burnt Clay Fps ( Non Modular ) Bricks Of Class Designation 7.5 , Providing Orange Colour Safety Footrests Of Minimum 6 Mm Thick Plastic Encapsulated As Per Is:10910 On 12 Mm Dia Steel Bar , P / Laying Of Interlocking Road , P / Making Storm Water Drain 300*450 Mm , P / F Of Chain Link Fencing Wall , P / Making Of Gate , Site Clearing , Surface Drasing , Cost Of Signage , Cost Of Notice Board , Cost Of Biomatric , Interactive Board, Interactive Diagonal: 1975 Mm, Usb Powered, Infrared, Multi-Touch ( 6 Touch ) , Supports Windows Xp, Vista, Windows 7, Windows 8, Window 10 And Linux + Ceramic Steel Board Size:- 120 X 180 Cm Make: Romark / Globus / Brio.With Resolution Xga 1024X768 , 3200 Ansi Lumen, Hdmi / Vga Inputs And Inclusive Of Ceiling / Wall Mount Kit, All Cables Connector And Conduits Etc. Make: Benq, Globus, Ricoh With Digital / Smart Podium: The Podium Shall Be Wheel Mounted Capable Of Moving In All Directions With A Facility Of Lock Them While The Electronic Podium Is In Use. The Enclosure Shall Be Made Of Polymer Powder Coated Steel Body With Wooden Top Panels, Designed To Work In Suitable Environmental Conditions. The Wooden Top Shall Have Lock And Key And Should Have A Sliding Cover For Opening / Closing Easily. The Podium Should Have Housing And Connectivity For Visual Presenter While The Visualizer Is In Use And Not In Use. At The Time Of Using The Visualiser , Drawer Can Be Opened And Visualiser Can Be Used. The Construction Of The Podium Should Be Such That, While The Podium Is Locked And Not Is Use, There Should Not Be Any Port Exposed / Visible On The Outer Body For Breakage / Mishandling.Built-In Highly Sensitive Interactive Panel With Adjustable Tilt ( Power Driven Motorized System ) & A Mechanism To Make The Panel Stable So That It Does Not Shake While Writingwith Following Minimum Features.Led 53.0 Cm ( 21 Inches ) Or Higher 1920 X 1080 Or Higherone Usb, One Vga / Dviport 4000 Lpi ( Lines Per Inch ) Approximately 200 Points Per Second 2048 Levels Display Panel Should Have Inbuilt Speakerdigital Teaching Device, Controller, I5 Pc With Wi-Fi Card Inbuilt Amplifier, Speaker And With Basic Visualizer, No Windows Make : Globus, Brio. Wall Mount 1 Kva Ups With Casingcomplete Installation Of The Entire Unit , Workstation Table, Panel Based Partition, Particle Board Edge Banded Top , High Back Chair, Pu Chrome Arm, Gas Lift, Chrome Base, Fabric Tapestry - Synchro Tilt , Executive Table, Particle Board Top W1650 X D1900 X H750 , Medium Back Chair, Chrome Cushion Arm, Gas Lift, Chrome Base, Leatheritte Tapestry , Visitor Chair, Chrome Cushion Arm, Chrome Plated Pipe Stand, Leatheritte Tapestry , Executive Table, Particle Board Top , High Back Chair, Chrome Cushion Arm, Gas Lift, Chrome Base, Leatheritte Tapestry , Single Seater Sofa, Wooden Frame, Ss Pipe Leg, Size In Mm - 830 ( L ) X 780 ( D ) X 755 ( H ) Leatherette , Three Seater Sofa, Wooden Frame, Ss Pipe Leg, Size In Mm - 1825 ( L ) X 780 ( D ) X 755 ( H ) Leatherette , Centre Table, Ss Pipe Frame, Chrome Finish, Toughned Black Glass, Top 12Mm Thick, Lower Glass 8Mm Thick , Cafe Chair, Without Arm, Ss Pipe Frame Chrome Finish, Leatherite Tapestry , Café Table, Ss Pipe Frame Chrome Finish, Granite Top, Size In Mm - 900 X 900 , Dual Desk, Plpb Edge Banded Top, Seat & Back, Powder Coated Pipe Frame, Top Size - 1050 X 400 X 18Mm Thick Overall Size - 1050 X 980 X 750 - Two Seater , Workstation Table, Panel Based Partition, Particle Board Edge Banded Top ( Rs. 69500 / 4= Rs.17375 ) , Medium Back Chair, Pipe Chrome Arm, Gas Lift, Chrome Base, Leatherite Tapestry- Swivel Tilt , Steel Almirah, 2 Glass Doors, 4 Adjustable Shelf, Thickness 0.8Mm , Student / Traning Room Chair, Pu Arm, Plpb Folding Writing Pad, Book Trey Under Seat, Powder Coated Pipe Frame, Fabric Tapestry, Marino 10002 Top Colour, Writing Pad Size : 535 X 300 X 18 Mm Thick , Single Seater Sofa, Wooden Frame, Ss Pipe Leg, Size In Mm - 830 ( L ) X 780 ( D ) X 755 ( H ) Leatherette , Three Seater Sofa, Wooden Frame, Ss Pipe Leg, Size In Mm - 1825 ( L ) X 780 ( D ) X 755 ( H ) Leatherette , Centre Table, Ss Pipe Frame, Chrome Finish, Toughned Black Glass, Top 12Mm Thick, Lower Glass 8Mm Thick , Conference Table, Particle Board Edge Banded Top W3600 X D1200 X H750 , High Back Chair, Chrome Cushion Arm, Gas Lift, Chrome Base, Leatheritte Tapestry , Cost Of Podium , S / I / T / C Of Split Ac 2 Ton , S / I / T / C Of Split Ac 1.50Ton , S / I / T / C Of I7 16 Gb Ram , 512Ssd , 1Tb Hdd With Windows 10 And Microsoft Preloaded Wire Opticalmouse And Keyboard With Spekar And Webcam , Canon Image Runner C3226 With Dadf And Toner , Hp Colour Laser Mfp 178Nw Printer , S / I / T / C Of Sony Tv Kd55x75k In5 , Supply Of 63Kva , 415 Volts Dg Set , S / I / T / C Of Water Cooler With R O System , Cat6 Utp Cable ( 300M ) , I / O Box Dlink , Path Cable Cat6 ( 1M ) , Path Cable Cat6 ( 2M ) , Ethernate 24 Port Gigabite Managed L3 Switch , 24 Port Patch Panel , Network Box 6U Rack , Instalation Charges , Cat6 Utp Cable ( 100M ) , Ethernate 16 Port Gigabite Managed L3 Switch , 16 Port Patch Panel , Network Box 4U Rack , Ip Camera ( Bullet / Dome ) , 8 Port Poe Switch , 8 Channel Nvr , Survillance Hdd-4Tb , Cat 6 Utp Wire ( 100M ) , 4 U Rack , 16 Port Poe Switch , 16 Channel Nvr , Cat 6 Utp Wire ( 300M ) , Instalation Of Cc Tv , Cost Of Maono Au-100 Condenser Clip On Lavalier Microfone With 6 M Audio Cable , Cost Of Fire Ectinguisher
Contract Date : Ref. Documents   |   Contract Value : Ref. Documents
BRR : 9456641 Tender For Balance Work Tourist Facilitation Center At Lalapur District Chitrakoot (U.P.), 1 Balance Work Tourist Facilitation center at LalapurDistrict Chitrakoot (U.P.) 2 R.C.C. (M-20) work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour, tools and plants etc. required for proper completion of the works. 3 First Floor 4 Second Floor 5 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete .R.C.C. columns(Concrete ofM-25 grade with minimum cement content of 330 kg /cum ) R.C.C. FOOTING 6 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete .R.C.C. columns(Concrete ofM-25 grade with minimum cement content of 330 kg /cum ) 7 First Floor 8 Second Floor 9 As in item no. 6 above but for slabs (Using 1:1.5:3 Mix concrete) [M-20] 10 First Floor 11 Second Floor 12 As in item 6 but for thelighterbeams i.e. having spans upto 6 m. (Using 1:1.5:3 Mix concrete) [M-20] 13 First Floor 14 Second Floor 15 Same as in item no. 11 above but in super-structure above plinth level including necessary cutting and moulding of brick work as required & also including honey combed brick work in thickness of wall more than one brick and for extra labour to above items. 16 First Floor 17 Second Floor 18 Same as in item no. 12 but in1:4 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work. Second Floor 19 P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. 20 Above Plinth Lvl. 21 Second Floor 22 15mm thick cement plaster on rough side of single or half brick wall of mix in 1:4 (cement & coarse sand) in plinth. 23 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chambers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth. (1) 1 cement : 6 coarse sand 24 Ground Floor 25 First Floor 26 Second Floor 27 15 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 sand 28 Ground Floor 29 First Floor 30 Second Floor 31 Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. 32 Ground & First Floor 33 Second Floor 34 Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (25 mm thick floor). 35 Providing and laying 8 to 10 mm thick ivory or light shade vitrified tiles of 600 x 600 mm size in flooring or skirting laid with cement mortar 1:3 (1 cement : 3 coarse sand) finished with cement slurry & with pigment grouting & polishing complete including supply of all materials, labour, T & P etc. required for proper completion the work excluding base concrete. 36 Ground Floor 37 First Floor 38 Second Floor 39 Providing and laying Polished Granite stone flooring in required designand patterns, in linear as well as curvilinear portions of the building allcomplete as per the architectural drawings with 18 mm thick stone slabover 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4coarse sand) laid and jointed with cement slurry and pointing with whitecement slurry admixed with pigment of matching shade includingrubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 11.56.1 Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent 40 Providing and laying Polished Granite stone flooring in required designand patterns, in linear as well as curvilinear portions of the building allcomplete as per the architectural drawings with 18 mm thick stone slabover 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4coarse sand) laid and jointed with cement slurry and pointing with whitecement slurry admixed with pigment of matching shade includingrubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 11.56.1 Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent 41 Providing and fixing Glass mossaic tiles on finished plain wall surface of size 20 mm x 20 mm x 4 mm in all colour, design , fixing in customize design as per direction of Engineer-in- Charge. The glass mosaic tiles to be fixed on the wall surface with the help of approved adhesive applied at the rate of 2.5 kg per sqm and grouting of the same. The rate is inclusive of all operation, material and required pattern approved by Engineer-in-Charge: 42 Supply and fixing 6 mm (1/4) thick China glazed tiles in flooring or in skirting or dado laid with 1:3 cement and approved coarse sand mortar finished with white cement slurry jointing and polishing complete including supply of all materials, labour and tool sand plants etc. required for proper completion of the work. 43 Ground & First Floor 44 Second Floor 45 Providing and laying brick coba 100 mm thick laid with M-150 class brick bat coba 7.50cm thick with gap of 15mm to each other, over 20 mm thick base of cement mortar 1:4 cement and coarse sand mixed with water proofing compound spreading cement slurry mixed with acrelic cement concrete water proofing compound filled gaps of coba & top of coba mortar mixed with water proofing compound in 1:4 cement and coarse sand mortar finised smooth & top mashed false square 30 cm x 30 cm and side wall parapet shall be mono tythic plaster wall up to 30 cm higher and junction and corner shall be rounded by brick ballast cement and coarse sand masonany Coba with top finised plaster mixed with acetic water proofing compound @ 2% by weight & including s/o all material, labour, T& P etc complete for proper completion of work. 46 Supply & fixing of flush doors commercial quality conforming to IS : 2202 Part I (1983) including fixing of wooden cleats & stoppers & including fixing & adjustment of hinges, bolts locks, handles, springs & other fittings but excluding their supply & including painting with two coats of black Japan paint on all iron fitting. Fitting with necessary screws to be supplied departmentally. 35 mm thick. 47 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 48 Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) 49 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.10.15.1 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 50 Providing & fixing of door / windows grill. Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. 9.48.1 Fixed to steel windows by welding 51 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.10.15.1 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) Angle iron chaukhat (40x40x5) 52 Fixing of Door, windows / ventilators chaukhats in position. 53 (a) Door chaukhats 54 (b) Window chaukhats 55 (c) Ventilator chaukhats 56 Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDMgasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately) Note: For uPVC frame, sash and mullion extruded profilesminus 5%tolerancein dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Casement window single panel with S.S. friction hinges (300x 19 x 1.9 mm), made of (small series) frame 47 x 50 mm & sash 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm andsingle glass pane glazing beadof appropriate dimension.(Area of window upto 0.75 sqm.) 57 Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardwares and drainage of water etc.After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels) made of (small series) frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area of window upto 1.75 sqm). 58 Providing and fixing factory made door frame (single rebate) made out of single piece extruded solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 62 mm width & 32 mm thickness, frame will be mitred & Jointed with self driven self tapping screws of size 38 mm x 4 mm & PVC solvent cement, including fixing the frame to wall with suitable dia & length anchor fastener as per manufacturers specification and direction of Engineer-in-charge. 59 Providing and fixing factory made 30 mm thick door shutter made of solid PVC foam profile. The styles & rails shall be of size 75 mm x 30 mm having wall thickness 5 mm. The styles, top & bottom rails shall have one side wall thickness of 15 mm integrally extruded on the hinge side of the profile for better screw holding power. The styles and rails shall be reinforced with M.S. tubes of size 33 mm x 17 mmx 1 mm, painted with primer , all four corners of reinforcement to be welded or sealed. Solid PVC extruded bidding (push fit type) will be set inside the styles and the rails with a cavity, to receive single piece extruded 5mm PVC sheet as panel. The styles & rails will be mitred cut, joint with the help of PVC solvent cement & self driven self tapping screws. Single piece extruded solid PVC lock rail of size 100 mm x 30 mm with wall thickness 5 mm & 15 mm integrally extruded in the middle of the lock rail & fixed with styles with the help of PVC solvent cement & self driven self tapping screws of size 100mm x 8 mm complete as per manufacturers specifications & direction of Engg.-in-charge. Non decorative finish 60 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections & other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia & size, including necessary filling up the gaps at junctions, i.e. at top, bottom & sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engg.-in-charge. (Glazing, paneling & dash fasteners to be paid for separately) : Powder coated aluminium (minimum thickness of powder coating 50 micron) 61 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm) 62 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. With 2nd class teak wood beading 62X19 mm 63 Polishing in high gloss/matt finish melamine clear polish on woodwork in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no.and then with sand paper of 160/180 nos.2. Applying two coats of sealer with spray gun and allowing sufficientdrying time for 1st coat and 2nd coat is allowed to dry for 8 to 12hrs.3. On drying of sealer coat, wet rubbing with emery cloth of finergrading with ample water to remove excess sealer layer andmake the surface further smooth after this wet rubbing, thensurface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs. 4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete asper direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) 64 Same as above but on new wood surface. 65 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade. New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). 66 Ground Floor 67 First Floor 68 Second Floor 69 Painting with silicon & acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces :Two coats. (For Internal wall surface & ceiling) (Asian Paint or equivalent) 70 Ground Floor 71 First Floor 72 Second Floor 73 Providing and applying white cement based putty of average thickness 2 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 74 Ground Floor 75 First Floor 76 Second Floor 77 Providing & fixing stainless steel sliding door bolts ISI marked to required colour or shade with nuts and screws etc complete.(a) 300mm x 16mm 78 P/Fixing stainless steel tower bolts ISI marked to required colour or shade with necessary screws etc. 79 (a) 250 mm x 10mm 80 (b) 200 mm x 10mm 81 Providing & fixing stainless steel handles ISI marked to required colour or shade with necessary screws etc. complete. 125 mm 82 Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. 83 Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick & 2100 mm long with SS screws etc .complete as per direction of Engineer-in-Charge. Powder coated minimum thickness 50 micron aluminium tubular handle bar 84 Providing & fixing of Rolling shutters of approved design made of 80 x 125 mm (3 x 18 gauge) cold rolled MS lath interlocked throughout their entire length and jointed together at the end by end locks end mounted on specially designed pipe shaft with brackets, side guides & arrangements for inside and outside poking with push & pull operation complete but excluding the cost of top cover and spring. 85 Providing & fixing 27.5cm long wire spring grade No. 2 for rolling shutters. 86 Providing & fixing top cover for rolling shutters. 18 gauge. 87 Providing and fixing ball bearing for rollong shutters. 88 Providing & laying of light cinder filling under floor of toilets & other sunken roofs. 89 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 90 Construction of drain along with apron. 91 Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). for ACP & STRUCTURAL GLAZING WORK 92 Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including:b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment , including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass. d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight.Structural Performance Deflection and deformation by static air pressure test (1.5 times desing wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm” 5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test” Tests to be conducted on site 6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000ml” 93 Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.26.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25-0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. 94 Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineerin- Charge. 95 Providing 10 mm thick plaster of Paris (gypsum anhydrous) ceiling up to a height of 5 m above floor level, over first class kail wood strips 25x6 mm with 10 mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame (frame work to be paid separately): 96 Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position with necessary stainless steel screws etc. 97 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished seamless type tubes 98 Supplying and installation of Extruded Aluminium linear facade and curves not exceeding 3000mm radius with 150X50mm block and 100mm space along with top and bottom cover and capping for individual profiles, fixed on extruded aluminum rail 80mmX50mm powder coated with dulux Eelctro black ace (or any specified shade) spanning between supports of maximum distance of 1500mm with the help of Sainless steel Non slip barb, steel rivet- galvanised to class 3, aluminium clip coated with external grade Matt powder coating, including the cost of necessary fittings and fixtures etc. as per approved drawing and design from Architect in charge (make Citadel/ Woodform Architectural or equivalent) 99 Providing and fixing stone jali 40 mm thick throughout in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali slab without any chamfers etc. Red sand stone 100 Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/ beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured. 101 Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately)Red sand stone - Exposed face machine cut and table rubbed with rough backing. 70 mm thick 102 Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required. 103 Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Wedge expansion type. Fastener with threaded dia 10 mm 104 Supplying, designing, fabricating, transporting, hoisting and fixing in position mural works in good quality of 70 mm Red sandstone and 6-10mm powder coated MS sheet in various elements for all levels. Stone shall be free from cracks, lines stains and even in shade for each element. The stone shall be fine grained and reddish or buff-colored (locally available). The work shall be carried out as per attached drawings with different process of i.e carving (manual/ by machine), ornamental work, traditional work, figure work (any type, any size), CNC cutting, moulding, etching, buffing and polishing. The carving and molding work shall be of very good quality. The work to be fixed in line, level and plumb in all respect with the use of brass clamps, pins, (to be paid separetely) dowels, cement slurry with matching pigment and Epoxy of Akemi Germany, Ardex Endura, MYK laticrete or approved make as required and as approved by the Architect in charge. 105 Centering and shuttering including strutting, propping etc. and removal of form for 106 Foundations, footings, bases of columns, etc. for mass concrete 107 Columns, Pillars, Piers, Abutments, Posts and Struts 108 SUB HEAD-I-SANITARY INSTALLATIONS 109 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid 110 Providing & fixing toilet paper holderC.P. brass 111 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. 112 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm witha single 15 mm C.P. brass pillar tap 113 Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer 114 Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. 115 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. 116 Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. 117 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 118 Providing and fixing C.P.brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 (including angle valve for WC flushing cistern, jet & kitchen sink) 15 mm nominal bore 119 Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm length 15 mm nominal bore 120 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 100 mm diameter 121 Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. 15 mm nominal dia 122 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore 123 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not lessthan 190 gms. 124 Providing and fixing Stainless Steel AISI 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting offittings and brackets,cuttingandmakinggoodthe walls wherever requiredKitchen sink with drain board 510x1040 mm bowl depth 200 mm 125 Providing & fixing PVC waste pipe for sink including PVC waste fittings Complete Flexible Pipe 32mm Dia 126 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15mm nominal bore 127 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15mm nominal bore 128 Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. 129 Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as perdirection of Engineer-in-charge and finished smooth. Granite Stone of approved shade 130 Providing and fixing of Kent Elite Plus Water Purifier (RO+UV+UF+TDS Control) with flow rate (50L/hr)including all its accessories, complete in all respect including testing etc. 131 Providing and fixing of Water Cooler (Voltas Make) including all its accessories, complete in all respect including testing etc. 132 Providing and fixing of storage type (pressurised type) electrichot water heater copper sheet container, 25 mm thickinsulation, stove enamelled M.S. jacket thermostatically controlled immersion heater with pilot neon lamp, suitable length of electrical cable and 15 amp 3 pin plug top, complete in all respect including testing etc. Capacity 25 Liters 133 SUB HEAD-II-WATER SUPPLY 134 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 135 Concealed work, including cutting chases and making good the walls etc. 136 For Internal Toilet 137 15 mm nominal outer dia Pipes 138 20 mm nominal outer dia Pipes 139 25 mm nominal outer dia Pipes 140 32 mm nominal outer dia Pipes 141 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 142 Internal work - Exposed on wall 143 20 mm nominal bore 144 25 mm nominal bore 145 32 mm nominal bore 146 Providing and fixing GI pipes complete with GI fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on Wall 147 Terrace loop & Tank Filling Pipe 148 50 mm nominal bore 149 65 mm nominal bore (i/c two coat of synthetic enamel paint) 150 Supply, fixing, testing and commissioning of following Electrical Actuator Single Phase 220V AC Operated Wafer Type Butterfly Valve - IP65CB - 230VAC, as per specifications:- 151 Lehry Make Automatic OHT Level Control System Consist of Following Items 1) LEHRY Make On-Off Type Electrical Actuator Single Phase 220V AC Operated Wafer Type Butterfly Valve with CI Body & SS Disc 2) Level Float Switch- 5M 3) Control Box (a) IP 65 Finishing(250 x 160 x 115)mm (b) LED Lamps: Tank FULL, Tank EMPTY, Power (c) Power supply toggle switch (d) Accepts 230V Single Phase power supply and provides 24VAC to float switch and 230VAC to valve coil. (e) Accepts NO/NC feedback from float switch. 50mm 152 Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work : 50mm diameter pipe 153 Providing, Fixing, Testing & Commissioning of XLPE Insulation of 9mm thickness on hot water supply pipes. Astral orequivalent approved complete in all respect as directed by Engineer-in-charge. 154 15mm dia (9 mm thickness) 155 20mm dia (9 mm thickness) 156 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 50 to 80 mm nominal bore 157 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 158 For vertical pipe connection with terrace ringmain 159 20 mm nominal bore 160 25mm nominal bore 161 32mm nominal bore 162 50mm nominal bore 163 65mm nominal bore 164 Providing and fixing MS pipe puddle flanges of required size with 600mm long with 6mm thick MS plate of size 300mm x 300mmof suitable size properly fixed in RCC walls of water tanks, including necessary welding complete in all respect as per details shown on darwings and directions of Engineeer-in-charge for water tanks. 165 25mm dia. 166 50mm dia. 167 65mm dia. 168 150mm dia. 169 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm dia (for rain water) 170 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A,including jointingwithsealringconformingtoIS: 5382, leaving 10 mm gap for thermal expansion. 171 Single Push Fit Coupler 172 110 mm dia 173 Single tee with door 174 110x110x110 mm 175 Plain bend 87.5 deg 176 110 mm dia 177 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm dia 178 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 179 SUB HEAD : IV - INTERNAL DRAINAGE 180 Providing, fixing, jointing and testing,uPVCSWR pipes, - type B conforming to IS : 13592to wall, ceiling and floor, approved quality, complete, for soil, waste & rain water drain including pushfit jointing with seal ring. (i) Single socketed pipes. 181 Internal Toilet (Soil & Waste Pipe) 182 75 mm 183 110 mm 184 Exposed on Wall (Soil & Waste Pipe) 185 110 mm 186 Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. 187 Bend without door (87.5°) 188 110mm bend 189 Bend without door (45°) 190 100mm 191 75mm 192 Y Fitting without door 193 100mm 194 75mm 195 Reduced Y Fitting without door 196 100mm x 75mm 197 Single Tee without door 198 110mm 199 75 mm 200 Single Tee with door 201 110mm 202 Reduced Tee with door 203 110mm x 75mm 204 Coupler 205 110mm 206 Clean Out Plug (COP) 207 110mm 208 75 mm 209 Vent Cowl 210 110mm 211 Providing, fixing, jointing and testing, unplasticized PVC pipes - 10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete, for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc. 212 For Wash basin & Urinal 213 50mm dia. Pipe 214 32mm dia. Pipe 215 Elbow (90°) 216 50mm 217 32mm 218 Elbow (45°) 219 50mm 220 32mm 221 T fitting 222 50mm 223 32mm 224 Providing, fixing, jointing and testing ,ofPVC Multi Floor Trap without jali ofminimum 50 mm water seal, making necessarycuttingin slabor floors and making goodincluding supports with cement concrete 1:3:6complete as approved by Engineer-in-Charge.110mm x 75mm x 50mm/40mm (Toilet) 225 Providing, fixing, jointing and testing , ofPVC NahaniTrap without jali ofminimum 50 mm water seal, making necessarycuttingin slabor floors and making goodincluding supports with cement concrete 1:3:6complete as approved by Engineer-in-Charge. 226 110mm x 75mm (Toilet) 227 110mm x 75mm (Kitchen) 228 Providing and fixing PTMT grating of approved quality and colour.Rectangular type with openable circular lid 150 mm nominal size square 100 mm diameter of the inner hinged round grating (including balcony) 229 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 150 x 100mm size P-type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 230 Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete: 100 mm diameter 231 Excavating trenches of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m ncluding getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m. All kind of soil Pipes, cables etc. exceeding 80 mm dia . But not exceeding 300mm dia. 232 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W.pipes including bed concrete as per standard design: 100mm dia SWpipe 233 COST OF SEWERAGE WORKS 234 Excavating trenches in all kinds ofsoil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m. up to 1.50 m depthPipes 80 mm to 300 mmdiameter 235 Opentimbering in trenches including shuttering and shoring complete. (Measurement to be taken of the face area timbered) Depth not exceeding 1.5 meter 236 Providing and laying NonpressureNP 2 class (light duty) RCC pipe with collars jointed withstiffmixtureofcement mortar in the proportion of 1:2 (1cement : 2 finesand ) includingtestingof joints etc. complete. 150 mm.dia. RCCPipes 237 Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design 150 mm. dia. 238 Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design. Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). With common burnt clay FPS (non modular) bricks of class designation 75 (i) For Sewer Line 239 Extra for depth for manholes: 240 Size 90x80cm with With common burnt clay FPS (non modular) bricks of class designation 7.5 241 Inside size 90x120cms and 90cms deep including CI cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58kg).With common burnt clay FPS (non modular) bricks of class designation 75 (i) For Sewer Line 242 Extra for depth for manholes: Size 90x120cm with With common burnt clay FPS (non modular) bricks of class designation 7.5 243 Providing orange colour safety footrests of minimum 6 mm thick plastic encapsulated as per IS:10910 on 12 mm dia steel bar conforming to IS:1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm thread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. 244 Supply, installing, testing and commissioning of non clog submersible type drainage / dewatering pumpset 245 COST OF EXTERNAL WATER SUPPLY WORKS 246 Providing & fixing G.I. pipes complete with G.I. fittings includingtenching and refilling etc. (external work) 247 65mm nominal bore. 248 50mm nominal bore. 249 32mm nominal bore. 250 Providing and fixing gate valve (with cap complete with bolts, nuts, rubber insertion etc. 251 65mm nominal bore. 252 50mm nominal bore. 253 32mm nominal bore. 254 Constructing masonry Chamber 90X90X100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand ) for sluice valve, with C.I. surface box 100mm, top diameter, 160 mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement :5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 255 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick,finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 256 RAIN WATER HARVESTING 257 RECHARGE PITS 258 Earth work in exacavation in trenches for foundations and for pipes cables etc. in ordinary soil(loam clay or sand) including lift upto 1.5 m and dressing of sides and ramming of bottom sand disposal of surplus excavated earth as directed by the Engineer i/c with in a lead of 50m. 259 In all kind of soil upto 1.5m depth 260 In all kind of soil upto 1.5m to 3.0m. depth 261 In all kind of soil upto 3.0m to 4.5m. depth 262 In all kind of soil upto 4.5 m to 6.0m. depth 263 Providing and laying in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded Stone aggregate 20 mm nominal size) and curing complete,including cost of form- work,in foundation and floors. 264 Class M-150 brick work in 1:4 cement coarse sand mortar infoundation & plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work. 265 Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement. 266 Providing & Fixing Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. 267 12mm cement plaster on rough side of single or half brick wall mix1:3 (1 cement : 3 Coarse sand) 268 Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design: With 20x20mm square bar 269 Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. M.D. -10- Circular shape 500mm internal diameter 270 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. Drilling of 300mm dia bore hole manually. 271 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia 272 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads& lifts, all complete as per direction of Engineer-in-charge. 273 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, inrequired thickness, for all leads & lifts, all complete as per directionof Engineer-in-charge. 274 Supplying, filling, spreading & leveling coarse sand of size range 1.5mm to 2 mm in recharge pit, in required thickness over gravel layer,for all leads & lifts, all complete as per direction of Engineer -incharge. 275 Gravel packing in tubewell construction in accordance with IS: 4097,including providing gravel fine/ medium/ coarse, in required grading& sizes as per actual requirement, all complete as per direction ofEngineer-in-charge. 276 DESILTING CHAMBER 277 Earth work in exacavation in trenches for foundations and for pipes cables etc. in ordinary soil(loam clay or sand) including lift upto 1.5 m and dressing of sides and ramming of bottom sand disposal of surplus excavated earth as directed by the Engineer i/c with in a lead of 50m. 278 In all kind of soil upto 1.5m depth 279 In all kind of soil upto 1.5m to 3.0m. depth 280 Providing and laying in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded Stone aggregate 20 mm nominal size) and curing complete,including cost of form- work,in foundation and floors. 281 Class M-150 brick work in 1:4 cement coarse sand mortar infoundation & plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work. 282 Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement. 283 Providing & Fixing Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. 284 15mm cement plaster on rough side of single or half brick wall mix 1:3 (1 cement : 3 Coarse sand) 285 Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design: With 20x20mm square bar 286 Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. M.D. -10- Circular shape 500mm internal diameter 287 DRAINAGE NETWORK 288 Excavating trenches in all kinds ofsoil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m. up to 1.50 m depth Pipes 80 mm to 300 mmdiameter 289 Providing and laying NonpressureNP 2 class (light duty) RCC pipe with collars jointed withstiffmixtureofcement mortar in the proportion of 1:2 (1cement : 2 finesand ) includingtestingof joints etc. complete. 150 mm.dia. RCCPipes 290 Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design 150 mm. dia. 291 Constructing brick masonry INSPECTION chamber 60x60x75 cm with bricks of class designation 50 in cement mortar 1:4 (1 cement : 4 coarse sand) including CI cover with frame LIGHT WEIGHT complete as perdesign. With FPS bricks 292 Constructing brick masonary open surface drain with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 fine sand) including earth excavation, 10cm thick bed concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and 25mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size) for filling haunches including 12mm cement plaster 1:4 (1 cement : 4 coarse sand ) with a floating coat of neat cement inside the drain, its top and exposed side including disposal of surplus earth complete as per standard design: 293 Drain 300 wide average.Depth 45 cm with R.C.C. slab 294 Drain 450 wide average.Depth 45 cm with R.C.C. slab 295 SEPTIC TANK & SOAK PIT 296 Size :- Length = 7.50 M. Width = 2.65M Total Depth =3.00M 297 Earth work in excavation over areas including disposal of excavated earth, lead upto 50m, disposed earth to be levelled and neatly dressed. 298 In all kind of soil upto 1.5m depth 299 In all kind of soil upto 1.5m to 3.0m. depth 300 In all kind of soil upto 3.0m to 4.5m. depth 301 Providing and laying of cement concrete in base excluding the cost of centring and shuttering by 1:2:4 (1 cement : 2 coarse sand : 4 gradded stone aggregae 40mm nominal size) 302 Brick work with brick of class designation 150 in foundation and plinth in cement mortar (1 cement : 4 coarse sand) 303 Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement. 304 P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. 305 12mm cement plaster on rough side of mix 1:3 (1 cement : 3 coarse sand) 306 Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars. 307 Providing and fixing C.I. tee at the inlet and outlet of septic tank. 308 Providing & fixing 75mm dia vent pipes. 309 Providing & fixing of 75mm dia cast iron terminal guard. 310 Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. 311 M.D. -10- Circular shape 500mm internal diameter 312 M.D. -2.5- Circular shape 450mm internal diameter 313 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design. With F.P.S. bricks 314 CONSTRUCTIONOFTUBEWELL(suitable for 1000 lpm yield) 315 Transportation Charges of drilling equipment including assembly and other material as required. 316 Drilling of 675 mm. dia by rotary machine 317 Supply & laying of 350 mm. dia housing pipe (8 mm. thick) 318 Supply & laying of 200 mm. dia blind pipe (8 mm. thick) 319 Supply & laying of 200 mm. dia slotted pipe (8 mm. thick) 320 Supply & fixing of 350 mm. dia Socket 321 Supply & fixing of 200 mm. dia Socket 322 Supply & fixing of 200 mm. dia Bail plug 323 Supply & fixing of 350 mm. dia well cap 324 Supply & fixing of 350x200 mm. dia reducer. 325 Supply & fixing of 350 mm. dia housing clamp 326 Supply & Filling of pee gravel 2 mm. 4 mm. in side of bore after lower and development as required as per direction of E/I. 327 Development by air compressor including Transportation. 328 Development by O.P. Unit including Transportation. 329 Supply of submersible pump suitable for tube well capable of pumping clear and cold water free from chemical and directly coupled with electric moter operating of 415 volt suitable for 3 phase 50 cycle A.C. Supply of following duty condition. A - Discharge of water in LPM 860 Approx size of discharge outlet in 80 mm. B - Total Head of pump set 45 m. 330 Supply and fixing of finolex or equivalent ISI marked submersible copper cable of size 2x3x2.5 sq. mm. 331 Supply of control panel cubical type wall mounted vermin proof with internal wiring duly enameled painted and mechanically finished having L&T of qul. Male switch fuse unit with HRC fuses, Ameter, Boltmeter, Selector switch, phase indicating lamp with bulbs, instrument fuses, power capcitor single phase preventor etc. complete set with supply of Jyoti or eq. Air break Star- Delta motro starter suitable for above submersible pump set. 332 Supply of 80mm dia M.S. column pipe of class C both and socketed with heavy sockets in 3/6 meter length and one end flanged complete with interlocking arrangements. 333 Supply of 80mm dia M.S. column pipe clamps with nut, bolts, packing etc. 334 Supply of 80mm dia C.I. double flanged ISI mark reflex valve of updadhya or equ. Make. 335 Supply of 80mm dia C.I. double flanged ISI mark sluice valve with hand wheel of upadhya or equ. Make. 336 Supply of C.I. double flanged bend of 80mm dia i/c cost of material and labour. 337 Supply of 80mm dia C.I. tee heavy quality i/c cost of material. 338 Supply of Guru/Fibing or equivalent make pressure gauge. 339 Erection & commissioning of pumping plants complete along with electric wiring. 340 Supply of steel wire rope of 1/2 size 341 S/B of 600mm x 600 mm x 6.0 mm G.I. plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and one earthing lead on one no. 8 to 10 SWG GI wite in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. , pipe and G.I. wire will be extra) 30 cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal. coke and salt at least 150mm thick alround etc. as per directions of E/I complete in all respects as per drawing. 342 S/F of one number 8 to 6 SWG G.I. wire in 15mm dia G.I. Pipe for earthing, laid in ground or in wall duly concealed includingn the cost of cement, sand labour. T&P other material required for proper completion of the work as directed at site. 343 S/F of aluminium conductor PVC insulated armoured, served, sheathed cable 1100 volts grade at a depth of 750mmbelow ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and on top.On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by E/I complete in all respects The armoring of the cable shall be properly connected with the earth conductor by clamps etc. 16 sqmm x 4 core 344 FIRE FIGHTING SYSTEM 345 Excavating trenches of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m ncluding getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m. Pipes, cables etc. exceeding 80 mm dia . But not exceeding 300mm dia. 346 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 100 mm nominal bore (pipe in pump room & external) 347 Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904as required : 2 way - 100 mm dia M.S. Pipe (Siamese& draw out connection) 348 SUB HEAD-II: INTERNAL FIRE FIGHTING WORKS(HYDRANT SYSTEM) 349 Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)(a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-F insulation, conforming to IS-325.(c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.(d) Suitable cement concrete foundation duly plastered and with anti vibration pads.450 lpm at 35 m Head 350 Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. (for terrace booster pump) 351 Providing and fixing in position the industrial type pressuregauges with gun metal / brass valves complete as required (for terrace booster pump) 352 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 100 mm dia. 353 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 100 mm dia. 354 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 355 80 mm nominal bore 356 100 mm nominal bore 357 Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Gunmetal 358 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.40 m 359 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Gun metal 360 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :Gun metal 361 Providingandfixing standard fire mans axe with heavy duty insulated rubber handle. 362 Providing of FHC Door made of 16 gauge MS Sheet with frame of size 105x70mm complete door and frame assembly including all hardwares (Concealed Flush handle,Allen Key Lock, MS Hinges, 5mm Thick Float glass) & accesories . The door to be painted with fire resistance paint. The scope shall also include the painting of the frame with the same paint as the shutter or complete as per direction of Engineer-in-charge.(Approx. size of door:900mm Wide & 1500mm Height) 363 Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. 364 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. 365 SUB HEAD-III: FIRE EXTINGUSHER 366 Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 367 Supply and fixing of fire extinguisher, ABC Type 6.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 368 Providing and fixing Fire related signages printed on photoluminescent U1000 aluminium sheet of 1.0 mm (+-10%) containing Lumigen II as base chemical, covered under UV stablized coating and of appropriate sizeincluding fixing on wall, door, ceiling etc. with proper clamps, hangers, cleats, anchor fasteners etc. complete in all respects as directed by Engineer-in-charge. 369 SUB HEAD-IV: ELECTRICAL WORKS (For Terrace Pump) 370 Supply and laying of aluminium conducter, PVC insulated armoured, served, sheeted cable 1000 bolts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top on surface, the cable run shall be fixed on M.S. clamps etc. of suitable size. 3CX6Sqmm AL XLPE Cable 371 Supply & fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per dire 3CX6Sqmm AL XLPE Cable 372 Fabricating & Supply, installing, testing and commissioning ofsheet steel clad floor mounting control panel having suitable size for control of 1 nos. booster pumps 5.5 KW/7.5HP each having suitable incoming MCCB, incoming voltmeter with selector switch and fuses. DOL Starter with hand reset overload cum single phase preventor type relay, Ammeters to read current in any one phase, alarm with reset push button which will automatically reset for the next cycle.(As per the Technical Specifications)(At Terrace floor) 373 Supplying and installing following size of perforated pre-painted M.S.cabletrayswithperforationnotmorethan17.5%,in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width x 50mm depth x 1.6 mm thickness. 374 SCHEDULE OF QUANTITIES FOR ELECTRICAL WORKS 375 SUBHEAD I- WIRINGPOINTS 376 Wiring point for light with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit pipe partly concealed in the wall and partly laid in slab alongwith the reinforcement before concreting, complete with 14 SWG copper earth continuity wire,GP Box, piano type switch & ceiling rose/angle/batten holder on 3mm thick phenolic paminated backalite sheet etc complete in all respect as directed including matching colour wash 377 Wiring point for fan / fresh air fan (light duty exhaust fan) with 1.5 sq.mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit partly concealed in wall and partly laid in slab alongwith the reinforcement before concreting, complete with 14 SWG copper earth continuity wire,GP Box , piano type switch & ceiling rose on 3 mm. thick backelite sheet etc., complete in all respect including matching colour wash. 378 Wiring point for 5Amp plug with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in heavy guage rigid steel conduit partly concealed in wall and partly laid in slab alongwith the reinforcement before concreting, complete with14 SWG copper earth continuity wire and piano type switch and socket etc., complete in all respect including matching colour wash. 379 Addition when modular type switches etc are used in place of piono type switches etc. in various wiring points. 380 Addition for light / fan points with modular type switchin place of piono type switch. 381 Addition for plugpointswith modular type switchin place of piono type switch. 382 Addition for Exhaust fanpointswith modular type switchin place of piono type switch. 383 Supply and fixing of power plug with 15A/250 V flush type switch and 5 Pin 15 A/250V flush type universal socket in suitable M.S. box of 175mmx100x50mm size with phenolic laminated bakellite sheet cover 3mm thick fixed with brass machine screws and cup washer. 384 Supply and fixing of power plug with 20A/250 V flush type switch and 5 Pin 20 A/250V flush type universal socket in suitable M.S. box including supply of all material, labor T&P etc. required for proper completion of work. 385 Supply & wiring of submains with 2 nos. 2.5 sq.mm & with 1 no. earth wire of 1.5 sq.mm FR PVC insulated 1100 V grade single core multistrand copper conductor cable in 20 mm dia heavy duty (2mm thick) PVC conduit complete, including supply of all material, labourand T&P etc. required for proper completion of the work as directed by Engineer I/C. 386 Supply and wiring of submain 2 number 4 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty( 2 mm thick ) 20mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 2.5 sqmm FRLSH PVC insulated multistranded copper conductor cable as earth contunity wire etc. complete in all respects. 387 Supply and wiring of submain 2 number 6 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty( 2 mm thick ) 20mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 4 sqmm FRLSH PVC insulated multistranded copper conductor cable as earth contunity wire etc. complete in all respects. 388 Supply and wiring of submain 2 number 10 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty( 2 mm thick ) 25mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 6 sqmm FRLSH PVC insulated multistranded copper conductor cable as earth contunity wire etc. complete in all respects. 389 Supply and wiring of submain 4 number 10 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty( 2 mm thick ) 32mm dia PVC conduit partly concealed in wall and partly laid in slab along with two number 10 sqmm FRLSH PVC insulated multistranded copper conductor cable as earth contunity wire etc. complete in all respects. 390 Supply and wiring of 4 number 16 sq. mm. PVC insulated 1100 V grade single core Copper conductor cable in 40 mm dia PVC conduit concealed in wall, with two number 10 sqmm single core Copper conductor cable as earth continuity wire drawn in coudit including matching colour wash etc., cable as earth contunity wire etc. complete in all respects. 391 Supplyfixingand concealing of20mm dia.2mm thick PVC conduit pipe with ISI mark embossed and with PVC acessories confirming to IS No. 3419 for drawing wires duly sealed at joints with original resin/ adhesive to make the complete piping rigid,plastering with cement sand mortar finished to level with matching colour including cost of material labour and T & P etc required for proper completion of work( forTelephone) 392 SUBHEAD II-INSTALLATION OF LIGHT FIXTURES AND FANS 393 Erection and testing of ceiling fan and regulator for room height upto 3.5mts. including supply of 3mm thick G.I. Pipe 19mm dia duly painted, complete in all respects. 394 Erection and testing exhaust fan on the exhisting hole with suitable size of rag bolts nuts and washers etc. complete in all respects. 395 Supply and fixing hexagonal/Round G.P. fan box of approved make made up of 1.0mm thick ISI Marked G.P. sheet spot weeldeed Four to Eight holes of 25.4 mm for pipe entry of the box. Holes should be semi-shuttered type with 0.5mm G.P. Sheet made upper & lower cover duly screewed fitted with 300mm round zink coted M.S Bar X 12mm & brand name should be embossed.Fixing with wiring conduit laid in the R.C.C roof before concreting alongwith supply of all material, labour, T&P etc. required for proper completion of the work. 396 Supply of Ceiling Fan with fan motor of A.C Permanent insulation, capacitor rating conforming BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment. The rated voltage 220/240 volts, 50Hz, 1-ph AC the fan assemble should consists of down road blades, shackle canopies etc and with double ball bearing system.BEE 5 Star rated-1200mm sweep 397 Supplyfixingofelectronic fan regulator(Modular) 120-280 V. ISImarked, on the existing switch board including making connetion, required material, labour T/P etc for proper completion of work to the satisfaction of Engineer in charge of work. 398 Supply and fixing of recess/surface mounting round 24 to 32 Watt LED Down Lighter having Powder coated die cast aluminium housing with extended heat sink, diffuser/ Reflector and driver set complete in all respect.CAT- AAA 399 Supply and fixing of 1X1 recess/surface mounting 18 Watt to 20 Watt LED Down Lighter having Powder coated die cast aluminium housing with extended heat sink, diffuser/ Reflector and driver set completed in all respects.CAT- AAA 400 Supply & fixing of LED Tube Light with Metal heavy dutyBox type batten Light fitting 2 x 22 watt suitable for up to 2 x 22 watt LED Polycarbonate tube light complete including tube etc suitable for both surface & surface complete in all respects.(CAT: AAA) 401 Supply & fixing of LED Tube Light with Metal heavy dutyBox type batten Light fitting 1 x 22 watt suitable for up to 1 x 22 watt LED Polycarbonate tube light complete including tube etc suitable for both surface & surface complete in all respects.(CAT: AAA) 402 Supply & fixing of recess/Surface mounting round 6 to 8 watt, LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set, suitable for 24Hr continuous Operation,complete in all respect.(CAT: AAA) 403 Supply and fixing of water tight oblong 10 watt LED bulhead luminaire with driverr set confirming to IP 65 and above Protection complete in all respect.(CAT: AAA) 404 Supply and fixing ofbatten/angle holder complete all respect. 405 Supply and fixing of 3 Watt LED Path / Walkover luminaire having powder cotated die cast aluminium body with drive set . Confirming to IP 65 Protection complete in all respect.CAT-AAA 406 Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with dirver set suitable for 40 to 50 Watt. Confirming to IP 65 protection complete in all respect.CAT-AAA 407 NON SCH. 408 Supply and fixing of 17 watt LED Mirror Light and complete in all respect. 409 Supply and fixing of 12 watt LED bulb complete in all respect. 410 Supply and fixing of 40 watt Tungsten Filament Antique Glass Light Incandescent Bulbs Vintage Base E27 Bulb Yellow Light. complete in all respect. 411 Supply and fixing of Dome Shape Pendent Light,complete in all respect, Make : Havells, Wipro, Philips ,Jaguar,Bajaj or Eq. 412 SUBHEAD III-DISTIBUTION BOARD 413 Supply and fixing of surface/flush mounting distribution boards with additional metal door without MCB complete in all respects.(CAT A) 414 8 Way SPN 415 12 Way SPN 416 6 Way TPN 417 8 Way TPN 418 4 Way VTPN 419 Supply and fixing of 6Amp to 32 Amp (10 KA)SP MCB in existing MCB, DB complete with connections as required. (CAT: A) 420 Supply fixing and making connection of following MCBS complete in all respects as per direction and satisfaction of engineer-in-charge.(CAT: A) 421 6 Amp. to 32 Amp. DP MCB (10 KA) C Curve(CAT: A) 422 40 Amp. TP MCB(CAT: A) 423 40 Amp. FP MCB(CAT: A) 424 63 Amp. FP MCB(CAT: A) 425 S&F and making connection of 25A 2 pole 30mA ELCB/RCCB of Din Rail Mounting complete in all respect as per direction and satisfaction to the Engineer in charge. 426 S&F and making connection of 40A 2 pole 30mA ELCB/RCCB of Din Rail Mounting complete in all respect as per direction and satisfaction to the Engineer in charge. 427 Supply and fixing Single Pole MCBS Blanking Plate complete in all respects. (CAT: A) 428 Non-Sch. 429 Supply fixing and making connection of following MCCBS complete in all respects as per direction and satisfaction of engineer-in-charge. 63 Amp. FP MCCB (25 KA) Thermal Magnetic release 430 SUBHEAD IV-CABLES 431 Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc 432 300 sq. mm 3.5 core 433 185 sqmm3.5 core 434 35 sqmm3.5 core 435 25 sqmm3.5 core 436 6 sqmm3 core 437 Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of EngineerIncharge 438 300 sqmm3.5 core 439 185 sqmm3.5 core 440 35 sqmm3.5 core 441 25 sqmm3.5 core 442 6 sqmm3 core 443 Supplying and fixing of Palm / pin type copper tin plated cables sockets (lugs) to the cable leads, insuslating with tape and making of connections etc. complete in all respects as per direction of Engineer-Incharge. 444 300 sqmm 445 185 sqmm 446 150 sqmm 447 95 sqmm 448 35 sqmm 449 25 sqmm 450 16 sqmm 451 6 sqmm 452 SUBHEAD V-EARTHING 453 Supply and burying of 600mm x 600 mmx6mm G.I. plate, vertically for earthing with its top atleast 3 mts. below ground level complete with 20mm G.I.pipe and funnel for watering and two earthing leads of No.8to10SWG G.I.wire in 15mm dia G.I. pipe upto switch board (from apron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm. square C.I. frame with hinged cover, masonary housing, alternate layers/of charcoal/ coke and salt at least 150mm thick alround etc. complete in all respects. 454 Supply and burying of 600mm X 600mm X 3 mm copper Plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I pipe and funnel for watering and one earthing lead ofone no. 8SWG copper wire in 15 mm dia G.I pipe up to switch board ( from appron to switch board the cost of G.I pipe and copper wire will be extra) 30 cm square C.I frame with hinged cover masonry housingalternate layers of charcoal / coke and salt atleast 150mm thick alround etc. as per directions of Engineer in charge complete in all respects. 455 Supply and laying of 32mm x 6mm G.I. strip from earth electrode directly in the ground as required complete in all respects. 456 Supply and Laying of 32mm X 6 mm Copper strip from earth electrode directly in the ground as required complete in all respects.. 457 Supplying & Laying of 25mmx3mm G.I. Strip for earthing purpose as required complete in all respects. 458 Supply & fixing of two number 8 SWG G.I. wire in 15mm dia GI pipe for earthing purpose as required complete in all respects. 459 L.T. PANEL 460 Supply, installation, testing and commissioning of electrical panel, modular type, front accessible only, free floor standing confirming to Minimum IP:43 degree of protection.The panel sheet structure shall undergo seven tank pre-treatment process before painting.The sheet steel shall be all of 2.0mm thick CRCA sheet.All the openable compartments of the panel shall be completely shrouded and provided with padlocking arrangement on all compartments including bus bar and cable alley chambers.The panel height shall not exceed 2200mm and the maximum operating height for any switchgear shall not be more than 1700mm.The panel shall be provided with minimum 75mm base channel frame fabricated from ISMC sections.All bus bar links in the panel shall be solid bus bars with coloured PVC shrinkable sleeves, no wires will be acceptable.Continuous earth bus shall run alround the panel with earthing studs provided at minimum 2 places.The control wiring shall be carried out with minimum 1.5/2.5 sqmm copper wires and adequate number of NO/NC, potential free contacts incorporated for remote operation of the starters.Proper sized cable termination gland plates shall be provided oncable alleys and knockouts for same shall be provided during fabrication stage itself.The panel shall be provided with a thermostatically controlled heating arrangement (200 W) to take care of high humidity conditions.A 5A socket service outlet (single phase) shall be provided in one of the compartments as ervice outlet in the panel.Panel shall be so designed at to have minimum 20% spare feeders/space.Panel shall undergo epoxy powder coated paint, colour as per IS:5 requirement.All cable terminations shall be from top.The complete panel shall be fuse less type, for control circuits 2A/6A MCBs to be used.All bus bars shall be of aluminium, electrolytic grade only.Maximum design density shall not exceed 1 Amps/Sqmm.All bus bars shall be insulated with coloured heat shrinkable PVC sleeved.All bus bar supports shall be non hygroscopic DMC/SMC supports. The panel shall be manufactured in conformance to requirements of local electrical inspector and it shall be contractors responsibility to get initial approval of drawings and also final approval of complete electrical works related to this section. 461 The minimum clearances between bus bars shall be as follows :Phase to phase - minimum 20mmPhase to neutral-minimum 15mmBUILDING MAIN LT PANELIncoming :1 No 250 Amp. 4P MCCB of 25KA (Ics=Icu)Breaking Capacity1 No 200 Amp. 4P MCCB of 25KA (Ics=Icu)Breaking Capacity1 No 125 Amp. 4P MCCB of 25KA (Ics=Icu)Breaking Capacity1 No 63 Amp. 4P MCCB of 25KA (Ics=Icu)Breaking Capacity1 No 200 Amp. 4P ATSMetering :1 Set of CTs one of 250/ 5Amp ratio for Multifunction Meter1 Set of CTs one of 200/ 5Amp ratio for Multifunction Meter1 Set of CTs one of 125/ 5Amp ratio for Multifunction Meter1 Set of CTs one of 63/ 5Amp ratio for Multifunction Meter4 Set of Phase Indication Lamp.Bus Bar :One (1) No. 300 Amp. FP aluminimum bus bar of suitable length.One (1) No. 160 Amp. FP aluminimum bus bar of suitable length.Outgoing :Phase indication lamps on each outgoing to be provided.100 Amps FP MCCB of 25KA - 2 No63 Amps FP MCCB of 25KA - 10 No40 Amps FP MCCB of 25KA - 1 No32 Amps DP MCB of 10KA - 2 NoSPARE & SPACEPanel described as above 462 METERING PANELIncoming :1 No 100 Amp. 4P MCCB of 25KA (Ics=Icu)Breaking CapacityMetering :1 Set of CTs one of 100/ 5Amp ratio for Multifunction Meter1 Set of Phase Indication Lamp.Bus Bar :One (1) No. 120 Amp. FP aluminimum bus bar of suitable length.Outgoing :Phase indication lamps on each outgoing to be provided.63 Amps FP MCB of 10KA - 2 No32 Amps DP MCB of 10KA - 9 NoSingle Phase Energy Meter- 8 Nos.Three Phase Energy Meter- 1 Nos.SPARE & SPACEPanel described as above 463 SUBHEAD VII-TELEPHONE SYSTEM 464 S/F MODULAR BOXES, BASE & COVER PLATE :- 465 Supplying and fixingfollowing size/modules, GI box along with modular base& cover plate for modular switches in recess etc as required. 1 or 2 Module (75mm X 75 mm) 466 S/F MODULAR TYPE SWITCH / SOCKET :- 467 Supplying and fixing following modular switch/ socket on theexisting modular plate & switch box including connections but excluding modular plate etc as required. 468 Telephone socket outlet 469 TV Antenna socket outlet 470 Supplying and drawing telephone wire following pair 0.5 sqmm FR PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/recessed steel/PVC conduit as required. 2 Pair 471 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated,shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/recessed steel/PVC conduit as required. 472 Supplying and fixing modular blanking plate on the existing modular plate& switch box excluding modular plate as required 473 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable 474 NON SCH. 475 Supplying and fixing following modular switch/ socket on theexisting modular plate & switch box including connections but excluding modular plate etc as required. RJ-45 Jack With Cat 6 -2M 476 Supplying telephone wire following pair 0.6 sqmm FR PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/recessed steel/PVC conduit as required. 5 Pair 477 S/f of 10 pair Junction Boxes for Floors and building with Krone connectors , with connection and punching of same 478 SUBHEAD VIII-CABLES TRAY & RACEWAY 479 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 480 100 mm wide x 50 mm depth x 1.6 mm thickness. 481 150 mm wide x 50 mm depth x 1.6 mm thickness. 482 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray bends (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 483 100 mm wide x 50 mm depth x 1.6 mm thickness. 484 150 mm wide x 50 mm depth x 1.6 mm thickness. 485 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray Tee (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 486 100 mm wide x 50 mm depth x 1.6 mm thickness. 487 150 mm wide x 50 mm depth x 1.6 mm thickness. 488 Providing, Laying and Fixing following Dia RCC Pipe NP 2 Class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 ( 1 Cement : 2 fine sand)including trenching ( 75 cm) deep and refilling etc. as required. 150mm dia 489 NON SCH. 490 Providing and Laying unplastisized rigid PVC pipe conforming to IS:13592 type A including jointing , cuttingand making good the walls & floors as per requirement. 150mm 491 Supply of AC 230/250 Volts, 50 Hz exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required 492 300mm sweep. 493 600mm sweep. 494 Supply of AC 230/250 Volts, 50 Hz Wall fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required 300mm sweep. 495 Making of following size of Cable Chamber made of 230 mm thick brick work in cement mortar (1 cement : 6 sand) with PCC 100 mm thick PCC base plastering of inner and outer surface with cement mortar including providing of Heavy Duty C.I Cover complete with digging, refilling and removal of surplus soil complete as required. 900 mm x 900 mmx 1000 mm deep 496 (NON SCH) 497 Supplying, Installation and commissioning of AMF start silent type 50 KVA DG set comprising of suitable BHPdiesel engine directly coupledto 3 phase Model- 4K1080TAG2 Engine BHP-80 rated at 1500 RPM, Water Cooled, Four Stroke Electric Start 4 Cylinders Diesel Engine conforming to BS 5514 with capacity Of 10%, complete in all respects with all required safety devices, fittings, batteries, accessories, filters, residential type silencer, control panel, inbuilt diesel oil MS tank of 990 ltrs. capacity made of 2mm thick M.S. sheet complete with M.S. fuel piping, G.M. gate valves, supports, control cable between generating set and control panel, exhaust piping with asbestos roping, antivibration mounting pads, first filling of lubricant oil totally enclosed in air tight, dust proof, weather proof, powder coated cubical type, sound proof as per CPCB norms acoustic enclosure made of 2mm thick CRCA sheet with with heavy duty doors, lockable arrangement, sound proof insulation with high density rock/mineral polymer/fibre cloth and perforated CRCA sheets, suitable to reduce the sound level upto 75dba approx. at a distance of 1 mtrs. as per CPCB norms Complete with axial flow heavy duty exhaust fans for adequate ventilation exhaust of hot air etc including making of cement concrete foundation of 1: 2:4 (1 cement 2 sand and 4, 40mm graded stone aggregate) as per manufacturer recommendation complete as per specifications and conditions as required. (The diesel engine and alternator shall be so rated to deliver the specified output at site condition complete with control cable etc. as required. 498 SUBHEAD XI- Solar Photovoltaic Power Plant 499 Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystal line silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium /GI structure of suitable strength with following components complete as required:-a)Solar Photovoltaic Module of capacity 330Wp or above,manufactured in India, conforming to IS 14286/ IEC61215, IS/IEC61730-Part-1, IS/IEC61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV module sused in solar power plants /systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years.b) Power Conditioning Unit (PCU) of 350- 800 V DC Input voltage range and 400V AC, three phase, 4 wire,50Hz+/-2.5Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency.c) Data Monitoring System complete with accessories.d) Fixing of Array junction box & Main junction box with IP65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required.e) Lightning and surge voltage protection.f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/ conduit lugs and other accessories etc. as required. 500 ESTIMATE OFFOR 4.5 Mt. WIDE C.C. ROAD 501 Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge etc( PWD-251) 502 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metr etc(DSR 16.1)*0.8222 503 Supplying and stacking at site. 16.3.1 90 mm to 45 mm size stone aggregate etc and Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density .(DSR 16.3.2 and 16.4)*0.8222 504 Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber,etc(DSR 16.43.2)*0.8345 505 Providing and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after making the joints dust free with high pressure air jet cleaners,etc(DSR 16.45)*0.8222 506 Providing and laying in position bitumen hot sealing compound for expansion joints etc. (DSR- 16.46.1*0.8222) Using grade A sealing compound. 507 TREMIX FLOORING IN PARKING AREA 508 Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge etc( dsr 2.1) 509 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metr etc dsr 16.1 510 Supplying and stacking at site. 16.3.1 90 mm to 45 mm size stone aggregate etc and Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density .(dsr16.3.2 and 16.4) 511 Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber,etc(sor 16.43.2) 512 Providing and laying in position bitumen hot sealing compound for expansion joints etc. (DSR- 16.46.1*0.8681) Using grade A sealing compound. 513 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). 514 [ LANDSCAPING WORK ] 515 Supplying and stacking sludge at site including royalty and carriage up to 1 km (sludge measured in stacks will be reduced by 8% for payment). 516 Carrigae of sludge upto 5 K.M. 517 Supplying and stacking at site dump manure from approved source including carriage upto 1 km (manure measured instacks will be reduced by 8% for payment) : Screened through sieve of I.S. designation 4.75 mm 518 Carrigae of manure upto 5 K.M. 519 Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge. 520 Spreading of sludge, dump manure or/and good earth in requiredthickness (cost of sludge dump manure or/and good earth to bepaid separately). 521 Digging holes in ordinary soil and refilling the same with theexcavated earth mixed with manure or sludge in the ratio of 2:1by volume (2 parts of stacked volume of earth after reduction by20% : 1 part of stacked volume of manure after reduction by 8%), flooding with water, dressing, including removal of rubbish and surplus earth, if any with all leads and lifts ( cost of manure, sludge or extra good earth if needed to be paid for separately). 522 Holes 0.9 m dia. and 0.90 m deep. 523 Providing & stacking of Phoenix sylvestris Roxb. (Wild date palm/khajur) of height 150-165 cm. in Big HDPE Bag as per direction of the officer-in-charge. 524 Providing & stacking of Pinus longifolia (Pinus) of height 90-105 cm. in cement pots of size 35cm as per direction of the officer-in-charge. 525 Grassing with selection No.1 grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the good earth shall be paid for separately). With grass Turf. 526 Sand Stone Pathway 527 Supplying & Laying of P.C.C. in 1:4:8 (1 Cement :4 Coarse sand: 8 stone aggregate 40 mm nominal size in base includinmg supply of all material labour T&P etc. 528 40 mm thick rubbed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints 3 mm thick, side buttered with cement mortar 1:2 (1 cement : 2 stone dust) admixed with pigment to match the shade of stone and pointing with same mortar. Red sand stone 529 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). 530 Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. 531 [ COBBLE PATHWAY ] 532 Earth work in excavation 533 Excavation by Manual means 534 Surface dressing 535 P.C.C. 1:4:8 536 B/W in 1:4 ( 1Cement :4 Coarse sand) 537 12 mm plaster in 1:3 outer 538 12 mm plaster in 1:3 inner 539 Providing & fixing Cobble Stone Flooring (10X10X10)cm filling of joints in 1:3 Cement mortarwith matching colour pigments all complete specification & direction of Engineer in charge. 540 [ ABSTRACT OF COST - CHHATRI ] 541 Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) : 300 mm dia piles 542 Excavation of foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. 543 Sand filling in plinth under floors including watering, ramming, consolidating and dressing complete including lead up to 50m and lift upto 1.5m and including cost of sand. 544 Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) and curing complete,including cost of form- work, in foundation and floors. 545 Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measured as per I.S.6313(PartII 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1)Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm (4) Treatment junction of wall and the floor 7.5 liters /sqm (5)Treatment of soil along external perimeter of building 7.5 liters/sqm. (6) Treatment of soil under apron along external perimter 5 liters/sqm. (As per manufacturers standard dilution) 546 R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20. 547 As in item no. 6 above but for slabs (Using 1:1.5:3 Mix concrete). 548 As in item 6 but for thelighterbeams i.e. having spans upto 6 m. (Using 1:1.5:3 Mix concrete). 549 As in item 6 abovebut inR.C.C.Raft foundation and footingwithapproved stone ballast. (Using1:1.5:3Mix concrete). 550 As in item 6 above but in R.C.C. columns in 1:1.5:3 having strength not less than M-20. 551 M-150 brick work in 1:6 (one cement and six coarse sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. 552 P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. 553 15 mm cement plaster on rough side of single or half brick wall of mix 1:4 (1 cement: 4 coarse sand) 554 Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) :Red sand stone - exposed face fine dressed with roughbacking. 30 mm thick 555 Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required. 556 Supplying, fabricating, transporting, hoisting and fixing in position good quality of 70 mm Red sandstone in various elements for all levels. Stone shall be free from cracks, lines stains and even in shade for each element. The The stone shall be fine grained and reddish or buff-colored (locally available). The work shall be carried out as per attached drawings with different process of i.e carving (manual/ by machine), ornamental work, traditional work, figure work (any type, any size), CNC cutting, moulding. The carving and molding work shall be of very good quality. The stones to be fixed in line, level and plumb in all respect with the use of brass clamps, pins, (to be paid separetely) dowels, cement slurry with matching pigment and Epoxy of Akemi Germany, Ardex Endura, MYK laticrete or approved make as required and as approved by the Architects. 557 Supply/FIXINGOF Installation Of Fountain 558 [ ABSTRACT OF COST - POND (SIZE - 30.0X 3.3 MT. ] 559 Earth workinexacavationintrenches for foundations in ordinarysoil (loan clay or sand) includingliftupto 1.5m and leadup to 30m.&including filling watering & ramming of excavated earthin to trenchesorintothespace between the building& thesidesof foundation trenchesor in totheplinth and removal & disposal of surplus excavated earthas directedbytheEngineer i/c upto adistanceof 30 m fromthe foundation trenches. 560 Providing and layingin cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded stone aggregate 40 mm nominal size) and curing complete,including cost ofform-work,in foundation and floors. 561 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size)(Footing) 562 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natu ral sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 563 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level or above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 564 Water proofing of pool as per spec.of DON building Chemicals. 565 Providing & fixing Glass Mosaic tiles in pond. 566 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab all colour and texture except black, Cherry/ Ruby red Area of slab over 0.50 sqm 567 Centering and shuttering including strutting, propping etc. and removal of form for. 568 Foundations, footings, bases of columns, etc. for mass concrete 569 Columns, Pillars, Piers, Abutments, Posts and Struts 570 Underground Sump 571 Supply installing , testing and commissioning of non clog submerssible tupe drainage/dewatering pumpset.Product Type: SUBMERSIBLE DRAINAGE PUMP Product ConfigurationPump Classification: Standard PumpComponent Materials Volute Material: Cast Iron FG 260 Impeller Material: Cast Iron FG 260Shaft Material: S.S AISI 410 Seal Material: Carbon/Ceramic/NBR/S.S 304 Motor Specifications Phase: 3 Voltage: 380-415VCable Length: Standard - 5 metresCable Length: Additional - 0 metres: 0Pipework Connection Float Switch: With Float Switch Solids Diameter LimitMaximum Solids Diameter: 10 mm Flow Rate = 205 LPM Each Pump Head = 9mEach Pump Set Detail = 1W+1S ( 2No. for LOWER GROUND TOILET) 572 Filling of carted earth. (230.13*4) 573 COST OF LIFT 13 PERSON 574 COST OF SOLAR PHOTO VOLTAIC PLANT 575 COST OF D.G.SET - 50 KVA 576 GST Extra as per applicable
Contract Date : Ref. Documents   |   Contract Value : Ref. Documents
BRR : 6886994 Provision Of Stfe Manufacturing Facility In Drdo Land Near Batl Complex At Thiruvananthapuram; SUBHEAD-I :Dismanteling Works , Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) , Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. , Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 10km initial lead, for all leads including all lifts involved. , Credit for Reinforcement steel obtained form above items , SUBHEAD-II :EARTH WORK & EXCAVATION : , Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 Sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. including pumping out water as required or liquid mud, , All kinds of Soils , Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. . including pumping out water as required or liquid mud, , All kinds of Soils , Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. , Supply,Laying, spreading and compacting stone aggregate of specified sizes to Rubble solling specifications in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density . , SUBHEAD-III :ANTI TERMITE TREATMENT : , Supplying chemical emulsion in sealed containers including delivery as specified. , Chlorpyriphos/ Lindane emulsifiable concentrate of 20% , Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : a) Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.:With Chlorpyriphos/ Lindane E.C. 15% with 1% concentration. , Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 15% with 1% concentration. , SUBHEAD-IV:PLAIN & REINFORCED CEMENT CONCRETE : , Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : , 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) , Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor,etc., up to floor five level, excluding the cost of centering, shuttering and finishing: , 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth. , Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. , Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement , Concrete of M25 grade with minimum cement content of 330 kg /cum , All works upto plinth level , All works above plinth level upto floor v level , Concrete of M25 grade with minimum cement content of 330 kg /cum , All works above plinth level upto floor v level , Add/ Deduct for using extra/ less cement in the items of design mix over and above the specified cement content therein. , Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap). 450 mm dia piles , Supplying, fabricating and fixing in position reinforcement bars at all levels and positions including the cost of steel, straightening, cutting, bending, binding and placing in position etc., as per drawings and specifications including the cost of binding wire, labour etc., all complete for reinforced concrete. , Thermo-Mechanically Treated bars (Fe 500 Grade or More) at all levels , Centering and shuttering including strutting, propping etc. and removal of form for : , Foundations, footings, bases of columns, etc. for mass concrete , Lintels, beams, plinth beams, girders, bressumers and cantilevers , Columns, Pillars, Piers, Abutments, Posts and Struts , Weather shade, Chajjas, corbels etc., including edges , Suspended floors, roofs, landings, balconies and access platform , Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. , Stairs, (excluding landings) except spiral-staircases , Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). , Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) , Vertical load testing of piles in accordingwith IS 2911(Part IV) including installation of loading plateform and Preparation of pile head or construction of test cap and dismantling of test cap arter test etc., complete as per specification & the direction of Engineer-in-charge Single pile upto 50 tonne safe capacity Routine test , SUBHEAD-V : STONE & BRICK MASONRY : , Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with, Cement mortar 1:6 (1 cement : 6 coarse sand). , Providing and laying autoclaved aerated cement blocks masonry with 150mm/200mm/230/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). , Providing and laying autoclaved aerated cement blocks masonry with 100 mm thick AAC blocks in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work. , SUBHEAD-VI :PLASTERING & SURFACE TREATMENT : , Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) : , Flush/ Ruled Pointing , 6 mm cement plaster of mix cement mortar 1:3 (1 Cement : 3 fine sand). , 12 mm cement plaster finished with a floating coat of neat cement of mix 1:4 (1 cement: 4 fine sand). , 15 mm cement plaster on the rough side of single or half brick wall of mix 1:6 (1 cement: 6 fine sand). , 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). , Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. , Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. , Providing and fixing 22 gauge chicken mesh wire at the junction of RCC and brick work with overlapping of 100mm on both sides, etc., complete. , White washing with lime to give an even shade: New work (three or more coats) , Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour (Two or more coats on new work) complete, as per manufacturer’s specification. , Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm , Applying priming coat , With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) , With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works. , Painting with synthetic enamel paint of approved brand and manufacture to give an even shade, Two or more coats on new work , French spirit polishing : Two or more coats on new works including a coat of wood filler. , SUBHEAD-VII :FLOORING : , Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in charge. (The panel shuttering work shall be paid for separately). (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately). , Deduct for using of M-20 grade concrete instead of M-25 grade concrete in C.C. pavement. , Making provision for contraction, expansion, construction and longitudinal joints (size 5x20mm) by groove cutting machine. , Providing and filling in position at expansion joints(size 5x20mm) with poly sulphate sealants of approved brand. , Supply and application of SealArm Tape TPE with adhesive ReArm Bond 4031 for 25mm width expansion joint. Work includes Insert backer rod same or higher dia into the joint and Apply of epoxy adhesiveReArm Bond 4031 first on the flanges of the joint followed by laying tape and press it on the adhesive. Again apply second layer of ReArm Bond 4031 on the tape (sandwiching the tape with adhesive both on top and bottom). Work including surface preparation all incl etc, not incl of joint protection works. Supply and apply of polyurethane sealant to expansion joint. work includes Insert backer rod of same or higher dia into the joint and apply polyurethane sealant - SealArm PU. Ensure that depth of sealant filling is atleast 1/2 of the width of joint as minimum criteria. , Providing and placing the 2.0mm thick and 300mm width aluminium plate as a protection for the tape. , Supplying & Fixing in position of pre-moulded, high performance joint filler board of 25mm thickness in expansion joints in Concrete, brick work, block work or isolation joints and should be rot free and with no bitumen content (ShaliTex Expansion Joint Filler Board of M/s Shalimar Tar Products or equivalent) , 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc., complete. , Providing cement skirting in CM (1:3) 18mm thick finished with a floating coat of neat cementetc., complete. , Supplying and applying Epoxy Flooring System as per the following Specification: Surface Preparation:- Providing and cleaning all floor area to make it free from dirt, dust and other contaminants, making grooves etc .as per manufacturers specification. Priming:- FloArm Primer 1260is a two-component solvent free, low viscous epoxy resin primer for both horizontal & vertical applications. It may also be used for producing leveling and scratch coats for surface preparation prior to final flooring. Epoxy Screed- FloArm ESF 2-M consists of graded aggregates bound is a epoxy resin binder. It is supplied as a 3component system, pre-weighed for on-site mixing. When laid it provides a smooth surface. FloArm ESF 2 M is designed for use in industrial environments where high abrasion and impact loads are likely. It provides a dense, impervious, coloured and chemically resistant floor surface which is hygienic and easy to clean. The designated floor area shall be surfaced FloArm ESF-2 a Heavy duty, trowel applied flowable 2-3 mm thick epoxy resin floor topping. The topping shall achieve a compressive strength of >50N/mm² and a flexural strength of >20 N/mm² at 7 days. , Epoxy Top Coat- FloArm SL-2 M consists of graded aggregates bound in a pigmented epoxy resin binder. It is supplied as a four component system, pre-weighed for on-site mixing. When laid it provides a smooth, light reflective surface. It is available in a range of standard colours. FloArm SL-2 Mis designed for use in industrial environments where high abrasion and impact loads are likely. It provides a dense, impervious, coloured and chemically resistant floor surface which is hygienic and easy to clean. The designated floor area shall be surfaced FloArm FloArm SL-2 M a Heavy duty, trowel applied flowable 2 mm thick epoxy resin floor topping. The topping shall achieve a compressive strength of >50N/mm² and a flexural strength of >25 N/mm² at 7 days. Make of Epoxy Flooring :- MYK or as Approved by Chief Construction Engineer (R&D)South. , Anti Static Flooring Surface preparation:- Providing and cleaning all floor surface including wall up to required height to make it free from dirt, dust, loose particles, wax, polish, efflorescence, laitance, curing compound and other contaminants by using wire brush, grinding all sharp edges to make it flush with the surface etc and complete as per manufacturers specification. , Priming:- Prepared substrates to be treated with FloArm SL Conductive system should be primed with FloArm Primer EP. FloArm Primer EP should be mixed in the proportions supplied by adding the entire contents of hardener can to the base can. Once mixed the FloArm Primer EP, should be immediately applied in a thin, continuous filmusing stiff brushes or rollers. Over application and puddles should be avoided. Porous floors may require two coats of FloArm Primer EP. FloArm Primer EP should be allowed to become tack free (over night Air dry) prior to application of Copper tape and subsequent FloArm SL Conductive Undercoat. Copper tape Fixing: - Make a suitable pattern to lay the copper strips of Copper band in a 5/5 m grid. , Screed:FloArm Cempo4 is a three part; epoxy modified cementitious, fine textured mortar for self-smoothing floors creeds in thinlayers of 4mm , Applying undercoat: The mixed undercoat shall be applied with a roller or brush on the primer at a material consumption rate of 6m²/kg for FloArm SL Conductive under coat. Care shouldbe taken to avoid over application or puddles. Theundercoat provides a Conductive system passagetoearth so correct application and strict adherence tocoverage rates are critical to the final electrical propertiesof the completed floor. Adequate ventilation and air movement are necessary for complete curing of undercoat. Thorough covering of earthing connections isessential. The Resistivity of the undercoat needs to bemeasured before applying the top coat (after overnight Air Dry). the surface resistance (FloArm SL Conductiveundercoat) should be: approx. 3x103- 9 x103 Ohm , Applying Topcoat: When mixed, FloArm SL Conductive Topcoat should bepoured immediately on to the surface and spread @2mmwith a steel trowel or a float. Immediately after applicationthe surface should be firmly rolled in perpendicular directions with a nylon spiked roller to help release anyentrapped air in the material and help to spread any slight trowel marks. Make of Anti Static Flooring :-MYK or as Approved by Chief Construction Engineer (R&D)South. , Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick. , Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. , Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Size of Tile 600 x 600 mm , Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @3.3kg/sqm including pointing the joints with white cement and matching pigments etc., complete. , Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. , Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. , Polished Granite stone slab of all colour and texture except Black, Cherry/Ruby Red , SUBHEAD-VIII :STEEL & WOOD WORKS : , Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete , Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete Fixed to openings /wooden frames with rawl plugs screws etc. , Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including MS pressed blet hinges 2.50mm thick with morter guards, lock strike plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: , Profile B, fixing with adjustable lugs with split end tail to each jamb , Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: , 35 mm thick , Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. , Providing and fixing to existing door frames, 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. , Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). , Providing and fixing the following hardware fittings of approved make: , 200mm long SS Tower Bolts , SS Aldrop 300mm long , Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. , 125mm long , Providing and fixing aluminium hanging floor door stopper (Single rubber stopper), ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. , Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. , Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. , Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm). , Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron)work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws.(Glazing, paneling and dash fasteners to be paid for separately) : , For sliding windows & ventilators including the cost in-built roller track, uPVC extruded interlocks, EPDM rubber,wool pile, zinc alloy ( powder coated) touch locks with hook, zinc alloy body with single nylon rollers (required weight bearing capacity ),neoprene gasket, G.I fasteners riquired size for fixing frame to finished wall and necessary stainless steel screws etc all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazingand paneling to be paid for separately, Only weight of aluminium sections to be measured for payment). , Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : , For fixed portion , Powder coated aluminium (minimum thickness of powder coating 50 micron) , For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) , Powder coated aluminium (minimum thickness of powder coating 50 micron) , Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): , With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm) , Providing and fixing Motorised Sliding Door of size 6 x 8 mCE Certified As Per European Standard BS EN 13241-1:2003+A1:2011 Single Side 0.50 mm thick GI Cladding Sheet Both Side Automation System : Bottom Drive Inbuilt wicket door with, locking arrangement & auto sensor - (w)1000 x (h)2100 mm Enamel Paint including all necessary fittings,hardwares etc complete as directed engineer in charge. , Providing and fixing Motorised Sliding Door CE Certified As Per European Standard BS EN 13241-1:2003+A1:2011 Single Side 0.50 mm thick GI Cladding Sheet Both Side Automation System : Bottom Drive Enamel Paint including all necessary fittings, hardwares etc complete as directed engineer in charge. , D1 ( 3.5 x 2.1) , D2 (2.5 x 2.1) , Providing and fixing Motorised GI Rolling Shutter CE Certified As Per European Standard EN 13241-1:2003+A1:2011 GI Slat Box Type Guide Powder Coated Motorised System : Indirect Drive With Std. Control Push Button - 1 No. Hood Cover - R/Meter including all necessary fittings,hardwares etccomplete as directed engineer in charge. , RS1 (4 x 3) , RS2 (3 x 3) , Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 -part 1 and M.S. top cover of required thickness for rolling shutters. , 80x1.25 mm M.S. laths with 1.25 mm thick top cover , Providing and fixing ball bearing for rolling shutters , STRUCTURAL STEEL : , Analysis, Design, Engineering, Preparation of Detailed Drawings, MAnufacturing, Fabrication, Supply, Loading,Transporting to SIte, Unloading, Erection of Steel PEB(Pre-Engineered Building)System, Consisting ofMS Platesof 345MPayield strength and Coating Thickness of 275gsm forcolumns, jack trusses, crane beams, Platforms, canopies, lattice girders, rafter , sub rafters ,at all elevations, levels and heights including aligning, leveling, providing and fixing bolts, nuts, washers, comprising MS angles, chann`els, joists, rails, tees, plates, rounds, squares,etc., of various sizes and other structural steel sections conforming to latest IS CODE including straightening, cutting, welding, bending to shape, bolting,and inclusive ofGrit / sand blasting and applying two coats ofSynthetic Enamel paint over one coats of approved Zinc Chromate primer . , The rate to include the cost of all materials, labours, tools, tackles, cranes, devices and plants, bolts, nuts, washers, clamps, welding electrodes and connection required for work, shims and packing pieces, any cutting, fabrication work required on electrically operated machines in the work shop including transportation to site and erection as per specifications and drawing complete. , a) For trusses , Rafters, gable frame ,lattice girders, Jack Beam, Crane beams, Columns.etc at all heights. , Supplying, fabricating, hoisting and erecting in position Purlins , cladding runners, girts of minium 345mpa yeild strength at all elevations, levels and heights including aligning, leveling, providing and fixing bolts, nuts, washers, comprising MS angles, channels, joists, rails, tees, plates, rounds, squares etc.,of various sizesincluding straightening, cutting, welding, bending to shape, bolting,Acid Pickling / GALVANISING of minium 120gsm &inclusive of following finishes. structural Grit blasting and applying two coats ofSynthetic Enamel paint over one coat of Zinc Chromate primerofapproved make and colouras per specifications and drawing complete. , Providing and fixing in position GI High Strength Foundation Bolts of approved make ofwith nuts of various diameters and lengths confirming with IS 4000-1992, Class 8.8 Type I for joining of various Structural components like Column, Rafters, Jack Beams,etc., including work at all levels and locations complete all as shown in the drawing , Roof Sheeting TOP SHEET : Supply of 360-degree FORTISS™ 470 standing seam panels shall be 470mm effective cover width, 73mm rib height, with strengthening rib/ flute in the pan for strength. The end lap shall be seamed with 360 degree seeming using Seamer machine. The sheeting material shall be 0.50 mm Base Metal Thickness (BMT), (0.55mm TCT, 0.58mm TPT). The steel sheet is having high tensile strength G300 (Fy=300Mpa), metallic coated with Zinc-Aluminium alloy (i.e. 55% Al, 43.4% Zinc, 1.6% Si - Zincalume), AZ150 (min 150 g/m2 total on both side), pre-painted with NextGen COLORBOND® XRW. The sheet conforms to general requirement of AS/NZS 2728 type 4 / IS 15965 class 3 durability of Tata BlueScope Steel make. The sheet shall be IGBC Green pro, Griha, EPD certified and steel sheet shall have brand marking of coated steel manufacturer (product details, date, mfg. name, etc.) on back side at regular interval confirming genuinity of the material. , ROOF INSULATION: Insulation shall be 50mm thick, density 48kg/m3 Rockwool with or without facing as per design requirement complying with IS8183 BS - 3958 Part-5. ASTM C592-80, as approved by engineer in-charge shall be laid uniformed over Purlin. SUB GIRTS: LYSAGHT ZED-plus™ purlins and Girts 1.5mm thick high strength galvanized steel with min 345 MPa yield strength, zinc coating of Z275 (275 g/m2 minimum coating mass) confirms to IS 277 / IS 15961 pre-punched to the required dimensions, suitable for roof and wall cladding support and portal framing up to a certain span. The design of cold formed ZED-plus purlins sections shall be subject to the requirement of IS 801 / AISI 1996, cold formed steel structures code. LINER - Bottom Sheet : Pre-painted Zincalume trapezoidal sheets shall be made of 0.45mm BMT (0.50mm TCT, 0.53mm TPT), G550 (min 550 yield strength), 1015mm effective cover width with five major corrugation, 28mm high rib spaced at 203mm c/c with subtle square fluting in the pan and the end rib shall have anti-capillary groove and return leg of Lysaght Trimdek. Color : COLORBOND XRW Standard or as Approved by Chief Construction Engineer (R&D)South. Make of Sheeting :-Tata Blue Scope or as Approved by Chief Construction Engineer (R&D)South. , Wall Panelling OUTER SHEET : Pre-painted Zincalume trapezoidal sheets shall be made of 0.45mm BMT (0.50mm TCT, 0.53mm TPT), G550 (min 550 yield strength), 1015mm effective cover width with five major corrugation, 28mm high rib spaced at 203mm c/c with subtle square fluting in the pan and the end rib shall have anti-capillary groove and return leg of Lysaght Trimdek. Steel should be metallic coated with Zinc-Aluminium alloy (i.e., 55% Al, 43.4% Zinc, 1.6% Si - Zincalume), AZ150 (min 150 g/m2 total on both side), pre-painted with NextGen COLORBOND® XRW. The sheet conforms to general requirement of AS/NZS 2728 type 4 / IS 15965 class 3 durability of Tata BlueScope Steel make. The sheet shall be IGBC Green pro, Griha, EPD certified and steel sheet shall have brand marking of coated steel manufacturer (product details, date, mfg. name, etc.) on back side at regular interval confirming genuinity of the material. , Wall INSULATION: Insulation shall be 50mm thick, density 48kg/m3 Rockwool with or without facing as per design requirement complying with IS8183 BS - 3958 Part-5. ASTM C592-80, as approved by engineer in-charge shall be laid uniformed over Purlin. SUB GIRTS: LYSAGHT ZED-plus™ purlins and Girts 1.5mm thick high strength galvanized steel with min 345 MPa yield strength, zinc coating of Z275 (275 g/m2 minimum coating mass) confirms to IS 277 / IS 15961 pre-punched to the required dimensions, suitable for roof and wall cladding support and portal framing up to a certain span. The design of cold formed ZED-plus purlins sections shall be subject to the requirement of IS 801 / AISI 1996, cold formed steel structures code. LINER - INNER Sheet : Pre-painted Zincalume trapezoidal sheets shall be made of 0.45mm BMT (0.50mm TCT, 0.53mm TPT), G550 (min 550 yield strength), 1015mm effective cover width with five major corrugation, 28mm high rib spaced at 203mm c/c with subtle square fluting in the pan and the end rib shall have anti-capillary groove and return leg of Lysaght Trimdek. Color : COLORBOND XRW Standard or as Approved by Chief Construction Engineer (R&D)South. Make of Wall Panelling :-Tata Blue Scope or as Approved by Chief Construction Engineer (R&D)South. , Providing and fixing tiled false ceiling of approved materials of size 595x595 mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross T of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main T at 600 mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. , Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. , 8 mm thick fully perforated calcium silicate board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process to give stable crystalline structure with minimum compressive strength 225 kg/ sq. cm, bending strength 100 kg/sq. cm , of size 595x595 mm, having perforation of dia. 10 mm with minimum perforated area 18 % with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.85, with 50 mm thick rockwool of 48 kg /cum backing. , Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, , shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : , 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) : 2011 (Board with BIS certification marks) , Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). , SUBHEAD- IX : MISCELLANEOUS: , Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: , a) Applying a slurry coat of neat cement using 2.75 kg/Sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. , b) Laying brick bats with mortar using broken bricks/brick bats 25mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. , c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ Sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. , d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement : 4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300mm square 3 mm deep. , e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.All above operations to be done in order and as directed and specified by the Engineer-in-Charge, with average thickness of 120 mm and minimum thickness at khurra as 65 mm. , Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. , Single socketed pipes of 110mm diameter , Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. , 110mm Bend 87.5° , 110mm Shoe (Plain) , Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. , 110mm , Providing and fixing Duraborad HD100(Formely Known as Capcell HD100/Silflex) The most Compressible Filler boad for expansion joint with Density of 100kg/cum.in 100mm Thickness , SUBHEAD-X : SANITARY SERVICES: , Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : , White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. , Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : , W.C. pan with ISI marked white solid plastic seat and lid. , Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc., including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. , Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. pan. , Providing and fixing white vitreous china flat back urinal basin of 430x260x350 mm size. , Providing and fixing C.P 15 mm Urinal spreader size 95x69x100 mm with 1/2 BSP thread and shapes, weighing not less than 60 gms. , Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required : , White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar taps. , Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. , Providing and fixing toilet paper holder, C.P. Brass. , Supply and fixing of 15 mm CP Health faucet Cum bib tap with 1.25 mts long tube with end nuts and hook and 1 no 15 mm CP brass angular stop cock with wall flange, Hook to be fixed with CP brass with suitable counter sunk screws, all of approved make etc., complete. , Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. , Granite of any colour and shade. , Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc., complete as per design approved by Engineer-in-Charge. , Granite Work , Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/Granite/stone work, including necessary holes for pillar taps etc., including moulding, rubbing and polishing of cut edges etc. complete. , Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. , Granite Stone of approved shade , Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. , 32mmdia Flexible pipe , Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. , Providing and fixing CP towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. , Providing, fixing, testing and commissioning of 75 mm pipe diameter uPVC SWR Type B pipe comforming to IS : 13592, including jointing with seal ring conforming to IS : 5382 for vertical pipe & Selfit uPVC Adhesive solvent joint inside in the toilet, including all fittings such as bends, junctions, inspection doors, offests, cowl, clean out, access pieces/plugs etc. complete the job. The rate shall be including all the engineered support at every one Meter (support, hanger, nuts/ bolts, anchor fasteners, fixing clamp/channels with U-bolts, etc) as per detail technical specification etc. complete the job. , 100mm dia upvc/ SWR Single socket , 75mm dia UPVC/SWR Single socket , Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete for UPVC SWG Pipes conform to is 13592-1992. , 100mm dia UPVC/SWR Single socket , 75mm dia UPVC/SWR Single socket , Providing and fixing PVC door bends as per IS - 13592-1992 single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. , 100x100x100 mm , 75x75x75 mm , Providing and fixing terminal guard, Sand cast iron S&S as per IS - 3989. , 100mm dia. , 75mm dia. , Providing and fixing M.S. stays and clamps for pvc pipes of diameter. , 100mm , 75mm , Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors, Sand cast iron S&S as per IS: 3989. , 100 mm inlet and 100 mm outlet , Cutting chases in brick masonry walls for following diameter sand cast iron/ centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size), including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 coarse sand) : , 100mm dia. , 75 mm dia , Supply and fixing in position best quality and approved make CP brass coat hooks with flanges fixed to wall/door shutters with necessary screws washers etc., complete. , SUBHEAD-XI :WATER SUPPLY SERVICES: , Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. - External Work. , 25 mm dia nominal bore , 32 mm dia nominal bore , 40 mm dia nominal bore , Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc., , 15 mm dia nominal bore , 20 mm dia nominal bore , Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : , 25 mm dia nominal bore , 32 mm dia nominal bore , 40 mm dia nominal bore , Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. , Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : , 25 mm nominal bore , Providing and fixing CP brass bib cock of approved quality : , 15 mm nominal bore , Providing and fixing CP brass stop cock of approved quality : , 15 mm nominal bore , Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931. , 15 mm nominal bore , Making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc. , SUBHEAD-XII : INTERNAL ELECTRIFICATION : , Point Wiring for Light/ Fan/ exhaust fan with 2 runs of 1100V grade 1.5 Sq.mm & 1 run of1.5 Sq.mm PVC insulated multistrand , FRLS , Copper conductorwires , run in and including 25mm dia heavy gauge PVC conduits concealed in wall / ceiling conforming to IS732 including all accessories such as junction boxes, conduit bends elbowsand anodised GI Switch box with modular switch and the box coveredwith front plate including connections to Earth terminal. , One Light point controlled by one 6 Aswitch. , Two Light point controlled by one 6 Aswitch. , Three Light point controlled by one 6 Aswitch. , Four Light point controlled by one 6 Aswitch. , Ceiling fan point controlled by one 6 A switchand electronic fan regulatorof 100 W step typewith concealed MS fan hook box. , Exhaust fanpoint controlled by one 6 A switch. , Point Wiring for Light/ Fan/ exhaust fan with 2 runs of 1100V grade 1.5 Sq.mm & 1 run of1.5 Sq.mm PVC insulated multistrand , FRLS , Copper conductorwires , run in and including 25mm dia, 14SWG black enameledMS conduits surface / concealed in wall / ceiling conforming to IS732 including all accessories such as junction boxes, conduit bends elbowsand anodised GI Switch box with modular switch and the box coveredwith stainless steel front plate including connections to Earth terminal. , One Light point controlled by one 6 Aswitch. , Two Light point controlled by one 6 Aswitch. , Three Light point controlled by one 6 Aswitch. , Four Light point controlled by one 6 Aswitch. , Point Wiring for Light/ Fan/ exhaust fan with 2 runs of 1100V grade 2.5 Sq.mm & 1 run of2.5 Sq.mm PVC insulated multistrand , FRLS , Copper conductorwires , run in and including 25mm dia , 14 SWG black enameledMS conduits surface / concealed in wall / ceiling conforming to IS732 including all accessories such as junction boxes, conduit bends elbows etc including connections to Earth terminal. , One Light point controlled by one 6A SP MCB , Two Light point controlled by one 6A SP MCB , Three Light point controlled by one 6 ASP MCB . , Four Light point controlled by one 6 ASP MCB , Point Wiring for Light/ Fan/ exhaust fan with2runs of 1100V grade 1.5 Sq.mm & 1 run of1.5 Sq.mm FRLS insulated multistranded Copper wires, run in & including 25mm dia, 14 SWGMS conduitssurface / concealed in Slab/ wall after necessary chase cutting with finishing/surface in wall / ceiling conforming to IS 732 including all accessories such as junction boxes, conduit bends, elbows and ceiling rose, anodised GI Switch box withmodular switch and the box coveredwith front plate and alsoincluding connections to Earth terminal. , One Light point controlled by one 6A Switch , Two Lights point controlled by one 6A switch. , Three Lights point controlled by one 6A switch. , Four Lights point controlled by one 6A switch. , Supply and laying of 25mm dia, 16 SWG black enamelled M.S. conduit concealed in wall/ ceiling/ floor including all accessories such as junction boxes, conduit bends, etc., complete as required for Telephone etc., , Supply and laying of 32mm dia, 16 SWG black enamelled M.S. conduit concealed in wall/ ceiling/ floor including all accessories such as junction boxes, conduit bends, etc., complete as required for Telephone etc., , Supply and fixing of 6A, 3Pin Socket outlet with 6Aswitch in Lighting switch boards. (Dependant). , Supply and fixing of 6A, 3Pin Socket outlet with switch of 6A ratingwith wiring of 2 Runs of 2.5 Sqmm and1 Run of 2.5 Sqmm FRLS, PVC insulatedmultistranded Copper conductorwires run inand including 25 mm Dia, 2 mm thick PVC conduit. (Independant). , Supplying and fixing suitable size GI box with modular Stainless Steelplate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in Clean Room). , Supply and Wiring with the following size 1100V grade PVC insulated multistrandFRLSCopper conductor wires inand including suitable size heavy gauge PVC conduit concealed in wall / Ceiling including all accessories suchas junction boxes, bends, elbows including end terminated with suitable lugs. , 2 runs of 2.5 Sq.mm wires with 1run of 2.5 Sq.mm wire in and including25 mm Dia PVC Conduit (For Lighting Circuit) , 4 runs of 6 Sq.mm wires with 2 runS of 6 Sq.mm wiresin and including32 mm Dia PVC Conduit (For Lighting Sub Mains) , Supply and Commissioning of thefollowing type Fluorescent/ Compact fluorescentlight fixtures on wall/ Ceiling including all fixing accesssories such as leads, etc complete as required. The Fluorescent/CFL fixtures shall be complete with Low loss copper ballast PF improvement capacitor, Bipin Rotor type lamp holder,starter, starter base, all prewired upto the terminal block. All fixtures shall besupplied with lamps. The Catalogue Numbers refers to Philips Make. , 36 W Surface mounted LED 4 Feet LengthLuminaire , (Philips : BN308C LED40S-6500 L120 PSU WH/or Equivalent as per approved makes) , 1 x12 WSurface MountedLED Luminaire , (PhilipsCat No : SM250C LED 12S-6500PSU WH or Equivalent as per approved makes) , 40 WRecessMountedLEDLight Fixture , (PhilipsCat No :RC 380 B LED 40S-6500 G4L60W60 PSU OD/Equivalent as per approved makes) , 20W Recess mounted DownLight Fixture , (PhilipsCat No DN296B LED20S-6500 PSU WH S2/Equivalent as per approved makes) , 36W Surfacemounted SquareLight Fixture , (PhilipsCat No SM36S -6500 G6L54W54PSU OD/Equivalent as per approved makes) , 40 W Bulk Head Light Fixture Indoor , (PhilipsCat No WT 202W LED 10S CW PSU S3 PC/Equivalent as per approved makes) , 210WLED High Bay Light Fixture , (PhilipsCat No BY616P LED200S 5700 WB PSU GR/Equivalent as per approved makes) , 104WLED High Bay Light Fixture , (PhilipsCat No BY225P LED104S CW SYWB PSU FG GR V2/Equivalent as per approved makes) , 36WLED2 X 2 Top openable cleanroom Light Fixtures , (PhilipsCat No CR652B LED36S-6500 PSU CA BO W30L120 WH /Equivalent as per approved makes) , Supply and Installation Testing and Commisioning of 1200 mmsweep single phase Ceilingfan including fixing accessories etc., complete.( BEE 5 star rated ceiling fan ) , Supply and Installation Testing and Commisioning of 600 mm dia sweep single phase wall mounted fan including fixing accessories etc., complete. , Supply and Installation Testing and Commisioning of 600 mm dia Air circulator single phase wall mounted with metal blades including fixing accessories etc., complete. , Supply and commissioningof305 mm sweep Exhaust fans with Metallic blades and MS gravity louversincluding all accessories / Installation materials required. , Installtionof Fluorescent/ Compact fluorescentlight fixtures on wall/ Ceiling including all fixing accesssories such as leads, etc complete as required. , Installation of 1200 mm sweepwhite colour Ceiling fan with standard down rod(600mm length down rod in false ceiling areas) andall accessoriesas required etc complete. , Installationof305 mm sweep Exhaust fans with Metallic blades and MS gravity louversincluding all accessories / Installation materials as required. , Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powderpainted including earthing etc. as required. (But without MCB/RCCB/Isolator) , 8 way (8 + 24), Double door , 4 way (8 + 12), Double door , Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuitbreaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. , 40A , Supplying and fixingof 6A to 32A rating 240/415V,10kA , C Curveminiature circuit breaker suitable for inductive load of following polesin the existing MCB DB complete with connections ,testing and commissioning etc complete. , Single Pole , Supplying and fixing following way, vertical type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powderpainted including earthing etc. as required. (But without MCB/RCCB/Isolator) , 8 way (4 + 24), Double door , Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, molded case circuitbreaker (MCCB), having a breaking capacity 25 KA in the existing MCB DB complete with connections, testing and commissioning etc. as required. , 160A 4P MCCB, 25 kA , Supplying and fixingof following rating 240/415V,10kA , C Curveminiature circuit breaker suitable for inductive load of following polesin the existing MCB DB complete with connections ,testing and commissioning etc complete. , 40A Three Pole MCB 10 kA , SUBHEAD-XIII : AIR CONDITION: , HVAC SYSTEM , All works should include Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over , All the equipments shall be five star rated only , All Techincal data sheet & drawing shall be submitted and get approved by department before supply , All equipment factory inspection shall be carried out by department , First prefers as per BOQ followed by Techincal specification , VARIABLE REFRIGERANT FLOW (VRF) / VARIABLE REFRIGERANT VOLUME (VRV) , Supply, Installation, Testing & Commissioning & Handing over of the following: , HIGH SIDE VRF/VRV EQUIPMENT , VRF/VRV HI BRID AIR-CONDITIONING EQUIPMENTS: (100% INVERTER TYPE ONLY TO BE QUOTED) - R410A Refrigerant , Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over of VRV/VRF air conditioning systemunit suitable for cooling and heatingmode having all hermetically sealed inverted type screw compressor with 5 Star and above Rating as per OEM comprising of Modular type high efficiency Twin Rotary MultipleCompressor with inverter, High efficiency heat transfer Cooling Coil suitable for Environment friendly R410a refrigerant,Air cooled propeller type condenser fan with DC motor drive,interconnecting piping, suction line insulation etc., Micro-processor control panel suitable for automatic operation,High speed calculation inverter control, active oil control mechanism incorporating all safety functions as per equipment specifications & other points as listed below: , The unit mounted starter panel shall be complete with IP-65 protection consisting of power disconnecting switches with fuses, soft starters, for compressor motors, under/over voltage trip, single phase preventers, communication card which can accept 4-20 mA or 2-10 Vdc analog signal. , All components shall be mounted on welded steel base frame, structural steel profiles/panels made out of galvanized sheet steel, protected with primary coat & finished with epoxy paint. , Modular type outdoor units equipped with highly efficient scroll compressors, withinvertertype compressor(s),special acryl precoated heat exchanger,low noise condenser fan,auto check function for connection error, auto address & UNIT Price shall be inclusive of outdoor stand price. Shifting & Installing of ODU as per shop drawing is part VRV vendor scope.(ODU Location & Capacity mentioned below). Shifting of Out door units from GF to repective location is part of VRF vendor scope . ODUs shall have service valve station for easy operations and monitoring of system , All VRV units should be compatible for third party BMS integration .necessary integrator should be consider in part HVAC VRF/VRV vendor scope (Bacnet over MSTP protocol to be considered for BMS compatibility requirement). Centralized controller shall be considered combined for all the VRF/VRV indoor and outdoor units and same to be located in a specific location as per client requirement. , Supply & providing of MS stand for VRF/VRV ODU along with proper supports-suitable for above configuration , Installation and pressure testing with nitrogen Gas, Vaccumising including all consumables for all system shall be part of scope of supply (Pre commissioning ) , First Filling, testing, commissioningincluding topping up of R410 A Refrigerant Gas. , Factory acceptance test to be conducted for all the units and cost of the same to be included , Testing tools and instruments of approved make and required quantity tobe maintained by Contractor , Contractor shall engage dedicated commissioning manager for project and shall coordinate for all testing activities and documentations , Central remote controller should be considered and provided along with VRF/VRV units , With all necessary accessories including vibration insolation i.e fixing etc complete. , Lifting, shifting and positioning of VRF/VRV System as per design location , Outdoor unit suibtable for both cooling & heatingmode having all hermetically sealed inverted typescroll compressor, minimum two compressors for above 14hP Modules, microprocessor based controller. , The unit shall be delived the rate capacity at AHRI conditions and work even at 50c ambient temperature with out tripping , The COP at AHRI conditions shall not be less than3.1 and IEER not less than 6.5.The motor shall be by IEE3 Rated , (*Note:The cost includes themaintenancegranttee includes 24months from the date ofCommissioning without any additional cost) MAKE: Daikin, Blue star, Voltas, Carrier, Trane. , Outdoor Unit (ODU) : Cooling Capacity : 218HP (OFFICE, LAB & QC LAB) , Outdoor Unit (ODU) : Cooling Capacity : 65HP (CLEAN ROOM) , Outdoor Unit (ODU) : Cooling Capacity : 220HP (WORK SHOP) , INDOOR UNITS , Indoor Unit (IDU):Coolingtype All the units should be supplied with thermostat control. The following Indoor unit capacities are required for each type of Room including heating & cooling mode. considered for Auto change over,failure status,overload sequencing etc. Along with proper supports-suitable for above configuration With all necessary accessories i.e fixing etc complete. , It should be suitable for BMS connectivity with necessary accessories. , 4-WAY CASSETTE UNIT , Four way Cassette 1.6TR , Four way Cassette 2.0TR , Four way Cassette 2.6TR , Four way Cassette 3.2TR , HI-WALL SPLIT UNIT , Hi-wall Unit 1.0TR , Hi-wall Unit 2.0TR , Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over of the following Inverter model with5 star capable Cool type split AC unit with high wall mounted Single Split indoor unit and outdoor condensing unit Hermetically sealed compressor suitable for operation on 230V, 50Hz, 1Phase AC supply capable of performing Heat, cool, dehumidifying, air circulating and filtering with cooling and condensing units with 3 mts of copper piping, insulation kit and 4 mts of 4 core copper flexible chord with cordless remote control etc., dual barrier coating in order to protect coil form oxidigation and with copper condenser only. , Hi-wall Unit 1.6TR5 star capable ofdelivering 19200 BTU/hr and above with operating on refrigerant R-32/ R-410A, COP not less than 4.5 , Hi-wall Unit 2.0TR5 star capable ofdelivering 24000 BTU/hr and above with operating on refrigerant R-32/ R-410A, COP not less than 4.5 , AIR HANDLING UNITS , Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over of following capacity floor mounted Thermal Break Double skin construction with internal and external sheets of 1.0 mm thickness with galavanizing of 120 gm/m2 ,Air handling unit made out of extruded aluminium structural frame work. Panels shall be made of 50 mm PUF injected panels having density 43 Kg/m3 in galvanised sheet casings having scratch free preplasticised coating on galvanised sheet on external side and plain GI inner sheet. The whole unit shall be mounted on spring isolators , i) The Air handling unit shallcomprise of fan section with Plug Fan/ Backward curvedfanwith limit load characteristics , spark proof fan. fan mounted on the scroll and not on the casing, coil section comprising of vrv/vrf water coil,stainless steel drain pan under coil section, Filter section comprising of prefilter 10 micron and 3 micron fine filters,mixing box along with RA and FAdampers etc. complete in all respect whether specifically speltor not but required to complete the system works. , The entireunitcasing shall be weather proof , made out of50 mm thk.43 Kg/ cum densitydouble skin PUF panels. The entire assembly of the unitshall be mounted on a rigid GSS base frame. Inner skinof the panel shall be 1 mm thickGSS plain and the outer skin shall be with 1 mm thk. Pre plasticized powder coated. The total unit along with VRV/VRF coils and hot water coil shall be AHRI certified. The face velocity of the coils shall not exceed 500 FPM . Theface velocity across the filters shall not exceed 500 FPM. , The coils and filters shall be full face of the unit. The fan and motor shall be mounted on a common base frame with cushy foots / spring isolator to avoid vibration transmission to the base of the unit. The motor shall be effiency 1 and with VFD compatable. , The fan shall be AMCA certified and motor shall be energy efficientEFF1. The fan out let velocity shall limit to 12 m/ sec. The fan access door shall have safetydoor interlock arrangement with motor. The unit shall be supplied withfire retardantdouble canvass connectionbetween the fan out let and supply air flange. , Variable frequency drives including harmonic filters and surge suppresors to be installed in independently with bypass starter panel and also differential pressure sensorwith cabling from the sensor located on the duct to the VFD for Air handling units of following capacity Motors including necessary fittings and fixing accessories etc., complete , The unit shall be supplied with an outletflange at the the supply air side along with opposed blade volume control damper. The damper casing and blades shall be made out of 16 G Aluminum. , The scope includes one set of commissioning filters along with the VFD & Starter panel with Bypass and control panels with MCB,MCCB. , The AHU unit shall outdoor type with all season weather proof protection , The noise level at all-round the unit shall limit to 60 dBA from 1 m distance to the unit. , The fan curves, coil selectionandtechnical data sheet shall be submittedby vendor for scrutiny. , The unit shall be included withAHU & VFD DRIVE STATER & CONTROL PANEL , The unit shall be included withAHU CONTROLL KITS WITH CORDED REMOTES , Unit shall be ultra violet lamp to kill germs/fungus , AHU1 - 30TR capacity , total air qty 12000 cfm, 65mm Static pressure with suitable High efficency motor, 24sqftarea of6 rowcoil(QC LAB). , Heater section should be with 8kW electric strip heater in 2 banks (QC LAB). , AHU2 - 52TR capacity , total air qty50000 cfm, 150mm Static pressure with suitable High efficency motor, 100sqftarea of6 rowcoil (ASSEMBLY HANGER). , Heater section should be with 12kW electric strip heater in 2 banks (ASSEMBLY HANGER). , AHU3 - 44TR capacity, total air qty 17600 cfm, 125mm Static pressure with suitable High efficency motor, 35.2sqftarea of6 row coil (WORKSHOP). , Supply and fixing of thyristor control Duct Heater Bank for humidity control 14kw capacity & necessary accessories to maintain RH (WORKSHOP). , Imported fittings like Y-Joints and headers etc as per the layout (additional supports should consider for both ends of the Y joint) With all necessary accessories i.e fixing etc complete. , CENTRAL CONTROLLER & REMOTE SYSTEM (FOR VRF UNITS) , Centarl controller integrating advanced I Touch screen display Controller type (System controller) for floor Indoor units with necessary software & spare parts. It shall be BMS compatible with BACNet over MSTP output to connect to the main IBMS system and showes real time data for both temperature Limitation and RH% in screen display. This Controllershall be stand-alone controller with features like visual navigation, graphical report, Multi-PC accessand have the capability to program for sequential operation of indoor units etc.,complete. , LOW SIDE VRV/VRF EQUIPMENT , REFRIGERANT PIPING , Interconnecting copper refrigerant pipe work duly insulated with elastomeric nitrile rubber typetubular insulation betweenindoor & outdoor units as per specifications . All piping inside the room shall be properly supported with hanger and all piping should be run in perforated cably tray.Cable tray qty specified seperately.. MS supports for refrigerant piping & cables, using angles, channels, Tees, flats, etc should be considered as part of scope.All MS supports shall be given a coat of red-oxide primer and two coats of synthetic enamel paint of approved colour. Class O insulation to be considered for the piping insulation. Cu.pipes shall be supported with PVC sleeves with clamps around and all wall/partition crossings shall have PVC sleeves , 41.3mm OD (insulation =19 mm thick) , 38.1mm OD (insulation =19 mm thick) , 34.9mm OD (insulation =19 mm thick) , 31.8mm OD (insulation =19 mm thick) , 28.6mm OD (insulation =19 mm thick) , 25.4mm OD (insulation =13 mm thick) , 22.2mm OD (insulation =13 mm thick) , 19.1mm OD (insulation =13 mm thick) , 15.9mm OD (insulation =13 mm thick) , 12.7mm OD (insulation =13 mm thick) , 9.5mm OD (insulation =13 mm thick) , 6.4mm OD (insulation=13mm thick) , DRAIN PIPE , Supply & Installation ofCPVC drain pipe insulated with 6 mm thick closed cell FM approved class O nitriler rubber insulation. Necessary U trap for units with clean out plugs to be provided. , 32 mm dia , 25 mm dia , Providing & fixing of 2 Cx 1.5 sqmm cu. cable for control cum trans-mission between Indoor unit and Out Door Unitthrough PVC Conduit. , Supply & providing of MS stand for VRV ODU along with proper supports-suitable for above configuration also including coat of red-oxide primer and two coats of synthetic enamel paint of approved colour. , Supply and installing following size of perforated Hot Dipped Galvanised iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections,joined with connectors,suspended from the ceiling with G.I. suspenders including including Cover on above tray, G.I. bolts & nuts, etc. as as required and also inculding 14 SWG GI cover sheet with 40x5mm GI strip on both sides. , 150mm wide x 75mmHeight, 1.6mm thick , 300mm wide x 75mmHeight, 1.6mm thick , 450mm wide x 75mmHeight, 1.6mm thick , MECHANICAL VENTILATION SYSTEM , Supply, Installation, Testing & Commissioning & Handing over of the following: , Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over of the Circular Inline fan Supplying, installing, testing and commissioning of low noise silent type Inline fan with @15mm WC static pressure. The motor shall be suitable for 220 volt single phase 50 cycles AC supply, 6/15 Ampplug and wiring between the fan and the socket andlow sound level exceeding not more than 50dBA. Fan shouldbe complete with all accessories, gravity louver/ shutter as required etc., as per manufacturer specification including transportation to site, all mounting arrangements like brackets etc.,as per specification including transportation to site, all mounting arrangements like brackets etc. It should be suitable for BMS connectivity with necessary accessories and cost of all accessories and all labour charges complete. , Circular Inline fan 100CFM/15mm WC static pressure , Circular Inline fan 200CFM/15mm WC static pressure , Circular Inline fan 400CFM/15mm WC static pressure , Circular Inline fan 500CFM/15mm WC static pressure , Circular Inline fan 600CFM/15mm WC static pressure , Circular Inline fan700CFM/15mm WC static pressure , Circular Inline fan 800CFM/15mm WC static pressure , CLEAN ROOM , CLEAN ROOM FALSE CEILING , Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over of the False ceiling panels are designed to fit within each other and suspended by threaded tension bars to the overhead support at fixed intervals , Standard Ceiling Panels have a composite construction of two skins of powder coated GI over an GI frame work with a sealed and insulated interior. 150-200 Kg per sq. mtr load bearing & factory manufacture only to be supply. , 50mmdouble Skin Walkable False Ceiling made of 0.45 mm both Top & Bottom with pre coated GI Sheetswith mounting accessories PUF as in fill (40 +/-2 kg./m3).False ceiling support rods lengthsuit to site condition. Note: 1.All ceiling joints and gaps between panel to panel, ceiling elements (such as HEPA module, diffusers, pipe & electrical drops etc.) etc. to be sealed usingApprovedfood grade silicon sealant of same or nearest colour as panel. The gap above panel to civil wall shall be properly closed with aluminium L - angle secured properly between civil wall and panels. All the gaps between panel to panel shall be closed with GI pre coated External Flashing . All the gaps between ceiling elements and ceiling panel shall be sealed using food grade silicon sealant of the same colour as the panel. , CLEAN ROOM PANELS , Standard wall partitions are a composite construction of two skins over an GI frame work with a sealed and insulated interior. Standard panel dimensions are 1200 mm. Standard panels have an overall thickness of 80 mm.Including Silicon Sealant. The self supporting internal walls are constructed with an interior floor Flashing to suit panel thickness.The Partition seams are sealed by silicone(Food grade) with a perfectly flush finishing. The panels should be factory manufacture. , CLEAN ROOM COVINGS , Extruded Aluminum Powder Coated /Anodized clip on type covings of 60mm radius for Panel to Panel and Panel to Ceiling. , Horizontal & Vertical Coving , 3DCorner Powder Coated , 2D Corner Powder Coated , AL powder Coated TEE Support for Ceiling Panels with threaded Rods and clamps , CLEAN ROOM DOORS , Doors are designed to fit flush into the wall panel / civil walls system on both sides and are supplied in different dimensions. Doors are fabricated from Pre Coated GI sheets & Pufas infill(48 +/-2 kg./m3). Shutter has sheet thickness of 1mm and the frame of 1.2mm. jam depth of door shutter inline with adjacent panel thicknessand shutter width of 40mm. Doors are available in various sizes as per the requirement. The following accessories are a part of the door: Note: 1.All joints between view panel and door panel to be sealed usingapproved food grade silicon sealantof the same or nearest colour as the panel. 2.Colour of the door panel:Same as Panel Colour or Blue 3.Double face VHB tapes of required thickness or silicon sealant to be provided on the periphery of the view panel frame to avoid any play between view panel frame and the slot in the door leaf. , Shutter Thickness: 40 mm thick , Stainless steel hinges (Any reputed Make) , Stainless Steel D type of handles on pull side , Stainless steel push plates on push side. , Heavy duty Concealed door closure , concealeddouble glazed Vaccumized View panel along with self adhesive tape and silicon sealant (500mmWx750mmH) with toughened glass with 6mm thick and black border , Mortice dead lock (ML100D) with both Side Key Operation Cylinder-Dorset , Concealed Flush Bolt Body with rod , Gasket at bottom for Double Door , Stainless Steel kick plates on both sides of 1.2mm thick with 300mm height for material transfer doors for Double Door. , DOUBLE DOOR SIZE , 3500mm Width X 2500mm Height Door (width of each door 1800mm) , VIEW PANELS ON MODULAR PARTITION , SINGLE GLAZED , All Viewpanel units are Double glazed and round profiled Epoxy based powder coated GI wall panel system. Thickness of 6/8 mm Tougened glass. The window system is completelyof food grade Silicone sealed. All veiw panels to have black border. Approx Size of view panels will be 800 x 1000mm , View Panel on 80mm wall panel , FALSE CEILING CUTOUTS FOR ELECTRICAL & HVAC GRILSS,LIGHT FIXTURES ETC. , Frame Work for Wall Panel Cutouts , Back Boxes for Electrical Sockets includes 3M, 2M, 6M, 8M, Single Phase, Three Phase industrials sockets respectively of apprvoed makes like Anchor, MK, North West & Legrand. , Frame work for False Ceiling Cutouts for Electrical & HVAC , PVC Conduit for Electrical Cables / Data Cables 24mm dia / 40 mm dia respectively , INBUILT RETURN RAISER , Supply and Installation of wall panel inbuiltReturn Air Risers of0.8 mm thick GI sheet & G4 Filter in aluminium frame work with proper fixing arrangement & fastening using SS 304 Dome nuts. to be provided up to the top of the false ceiling for HVAC duct connection. along with Butter fly Dmpers on the Top side. , Inbuilt raiser 600 x 600 , GI RETURN AIR FILTER WITH SS PERFORATED SHEET MODULE , Supply & installation of Return Air Raisers SS PERFORATED SHEET MODULE WITH 20 MICRON FILTER ASSEMBLY TO FLUS FIT THE RETURN AIR RISER PANEL. The RA raiser shall be adequately supported to ensure the rigidity. , 450 mm x 450 mm x 450 mm , Supply and Laying ofSelf levelling Expoxy flooring with Floor Preparation work and application ofone coat primer, screed and finishing with Self levelling Epoxy up to a max of 2mm of approved Colour , INSULATED FLEXIBLE DUCT WITH NECESSARY FIXING CLAMPS ON BOTH SIDE FOR TERMINAL HEPA MODULE , Supply, Installation, Testing and Commissioning of The insulated flexible duct of class 1 air duct, light weight, strong, fully flexible & made of double lamination of films permanently bonded to a coated spring tough steel wire helix. The thermal efficiency is ensured with a blanket of fiberglass wool insulation in between. Necessary Fixing Clamp on both side shall be considered. (With Spigot Connection & Rigid GI Round Duct). Note: Rigid GI Round Duct area shall be part of GI Ducting. Each Flexible connection shall not be more than 1 Mtr. , 200 mm Dia , TERMINAL HEPA FILTER WITH MODULES , Supply, Installation, Testing and Commissioning of H14 HEPA Filterwith Housing & Damper (Bottom Discharge Module Type with SS304 perforated grille of 16 SWG sheet along with SS chain link). Complete Housing (Sides + Top) made of extruded aluminium anodized material and low leakage aluminum collar damper with operating bevel gear arrangement, Diffuser Plate,Housing shall be suitable for fixing the Gel Sealtype (Polyurethane gel) terminal HEPA filter (H-13) with Protective Expanded Metal Screen. The Filter Housing shall have provision for smoke aerosol test point and differential pressure measuring point. The filter mounting box shall have a provision to replace filter & control the airflow from inside conditioned space. The HEPA filter modules are of the following sizes: , Plenum box size of 485x485x220H (530X530mm Flange to Flange) inlet collar with Diffuser plate & TOP entry 305 Sq / dia Collar with necessary clamps completewith gel seal filter minipleat H-13 of Size: 450X450X70mmwith DOP port and bevel gear arrangement room side operation damper. , PRESSURE MONITORING SYSTEM , Supply, Installation, Testing and Commissioning of Compound Magnahelic gauges housed in a SS304 front cover (50-0-50 Pa) complete with PVC tubing and SS perforated nozzle (For Installation in Clean Room Panel for Classified Areas) , MISCELLANEOUS , Commissioning of Classified Areas with Validation reports comprising of: , AHU & Duct leakage testing with pressurization (As per SMACNA air duct leakage standards). This process to be documented. , HVAC testing adjusting and balancing as per ASHRAE standard. , Air balancing with flow hood meter , Room Temperature & Humidity mapping for 24 hours and monitoring for 3 days. , Room pressure balancing with monitoring for 3 days. , HEPA Filter Integrity Test. , Particle count test , Providing all documentation of DQ, IQ, OQ & PQ in approved formats. , The Validation has to be carried out for minimum 3 working days continuously for Air flow, Temperature and Humidity. For Room Pressure Differential continuously for 3 working days. In case of any non compliance the system has to be set right and the Validation has to be carried out once again as per the above schedule. Validation has to be carried out by valued Certification ISO 14644-1 is a widely recognized certification .Its shouldissued by the International Organization for Standardization (ISO) or The FDA, Health Canada, and the EU recognize this certification. , Clean Air Devices Equipments , Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over of personal Air shower , single entry and single exit,high velocity, low pressure system SS304 nozzles,pre and HEPA fillers, completely self contained unit, utilizing low wall return (floor grill type not accepted) , The Unit shall be consisting of ISO class 8 clean room compatible pre-fabricated units built up, in place having fluorescent lamp with acrylic cover, electronic ballast , both side red and green indicators, elector-magnetic latches on both sides of Dorma make to ensure both doors do not open simultaneously, 5.0 mm thick viewing glass,SS304 finish handles of Dorma make, door closer with hold open arm of Dorma make, blower, control wiring, emergency stop switch etc. , For 3 persons entry , Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over of stainless steel centrifugal air curtain having following specification.The product should be made up stainless steel 304Grade having 3 Blowers(in M.Steel), 2 Motors operating on three phase , Power =1650 Watt having RPM (Max/Min = 2700) and CFM. Overall Dimension of 6000X230X212(mm) with Noise level < 66 db. Air Curtain should be provided with velocity control switch and a Door sensor. The product should carry manufacturers warranty of one year from the Date of Supply. Along with Fabrication work of providing 2/1 MS Pipe , Tin Sheet as cover, Bracked and screws*Variations acceptable in parameters above - 5-10% The Product should be Supplied along with PVC curtains & SS Bracket for PVC Support. Supply, installation, testing and commissioninging of transparent blue PVC Strip curtain,these medium weight strip will help with temperature control or dust exclusion without impeding access, It is suitable for the door is the main entry gate of the premises, means exposed to air.The Product should be complete in all aspect as per Engineer incharge instructions , Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over of stainless steel centrifugal air curtain having following specification.The product should be made up stainless steel 304Grade having 2 Blowers(in M.Steel), 2 Motors operating on three phase , Power =1650 Watt having RPM (Max/Min = 2700) and CFM. Overall Dimension of 3500X230X212(mm) with Noise level < 66 db. Air Curtain should be provided with velocity control switch and a Door sensor. The product should carry manufacturers warranty of one year from the Date of Supply. Along with Fabrication work of providing 2/1 MS Pipe , Tin Sheet as cover, Bracked and screws*Variations acceptable in parameters above - 5-10% The Product should be Supplied along with PVC curtains & SS Bracket for PVC Support. Supply, installation, testing and commissioninging of transparent blue PVC Strip curtain,these medium weight strip will help with temperature control or dust exclusion without impeding access, It is suitable for the door is the main entry gate of the premises, means exposed to air.The Product should be complete in all aspect as per Engineer incharge instructions , SS/PP Furniture , Design, engineering, fabrication, supply, erection and testing of Cross over bench made up of 10 mm thick PP sheets of size which has to fully fixed in the designated placein the changeroom, with heat welding .Bottom of bench will have pegion holes for keeping dayshoes/CR sleepers of equal size 250 mm X182 mm in two rows. , Design, engineering, fabrication, supply, erection,testing and commissioning ofgarment cubicle compatible for ISO class 8 cleanroom either SS304 sheet material for keeping maximum 15 cleanroom garments including 15 sets of garments, sliding doors, glazing, UV light, Pre filter, HEPA filter and blower for recirculation of air, complete ready to use. , ELECTRICL LIGHTS AND ACCESSORIES , LIGHT FIXTURES , Supply,Installation, Testing & commissioning of following LED light fittings for lighting fixture with accessories and LED chip. The Luminaire shall be with CRCA housing and Luminaire and an operating Voltage Range of 120 - 277V, Internal Surge Protection 2.5KV. , 40W 2x2 (600mmx600mm) LED Screw less Clean room recess mounted bottom opening luminaires with toughed glass with diffused acrylic cover, construction of the housing with engineering push back mounting arrangement system of Approved make. System output 4000 lumens to be considered.(Philips or equivenlant) , Electrical Cabling with PVC Conduiting for the Lights 3 Core1.5 Sqmm , POWER SOCKETS , Supply, Installation, Testing & Commisioning of following Plug sockets & Push buttons. The assembly shall be housed in metal box / on partition / on wall concealed type. Rate shall include the internal wiring, terminations, GI back box and front face plate, enclouser with fixing accessary like lugs, screws, blot nuts, ferruls etc. as per tender technical specifications.Necessary wall chipping, drilling & fixing of back box in concelead type. Rate shall be included backbox fixing concelead on the walland chipping along the wall fixing chicken mesh and making good surface of wall as required at site. Note : Modular sockets Back box should be considered 45mm depth only. , Emergencystop push button station with enclosure fixed on wall or on required MS angle support with all its accessories of approved make. , EARTHING , GI Plate Earthing , Supply and Laying of following earthing strips / earth wire of the following sizes with required accessories like clamps,bolts & nuts, painting. Two numbers of earth strips should run along with cable tray/civil wall with proper using bolt and nuts for strips connectivity and two earth points shall be end terminated for all equipments, motors, all Electrical and ELV panels, DB etc., refer the earthing schematic for considering the earth strips. , 50mmx6mm GI Strip , DRAIN PIPE , Supply & Installation ofPVC drain pipe insulated with 9 mm thick closed cell FM approved class O nitriler rubber insulation. Necessary U trap for units with clean out plugs to be provided , 40mm dia , Sheet Metal Work usingFactor Fabricated Duct with Ductmate (TDF) Flanges for all sizes of the duct. Fabrication as per SMACNA Standards , Galvanizing shall be Class VIII – light coating of zinc, nominal 120 gm / sqm surface area and Lock Forming Quality prime material alongwith mill test certificates.In addition, if deemed necessary, samples of raw material, selected at random by owner’s site representative shall be subject to approvaland tested for thickness and zinc coating at contractor’s expense. , All duct construction and installation shall be in accordance with SMACNA standards.In addition ducts shall be factory fabricated utilizing the following machines to provide the requisite quality of ducts. , All ducts shall be fabricated and installed in workmanlike manner, conforming to relevant SMACNA codes. , To ensure the air tightness, all ducts shall be checked with Duct pressure Test after completion of duct installation but before applying insulation , Guide vanes to be installed in elblow, reducers and other accessories , Stiffernner to be considered for ducts with more than 1200mm wide ducts , Duct joining shall completed with adhesive type gasket and sealant , All ducts needs to properly supported with suitablewire supports as per makes given in make list. The cost shall be inclusive of anchor fastners/wedge supports suiting to steel structure. , With all necessary accessories i.e fixing etc complete. , Rectangular Ducting , Sheet Metal Ducting As per Specification. Pressure 500 Pa , 24 G Ducting with Factor Fabricated Duct/ TDF flanges , 22 G Ducting with Factor Fabricated Duct/ TDF flanges , 20 G Ducting with Factor Fabricated Duct/ TDF flanges , Thermal & Acoustic insulation , Thermal Insulation for ducts , Supply, installation and testing of Class- O, 25 mm thick Closed cell elastomeric insulation for thermal insulation for indoor supply air ducts with density not less than 50 kg / cum. Microban antimicrobial protection insulation material to be fire retardant. Joining tapes & low VOC adhesive to be supplied with the insulation material by the insulation material manufacturer. , Supply, installation and testing of Class- O, 19 mm thick Closed cell elastomeric insulation for thermal insulation for indoor supply air / return air ducts with density not less than 50 kg / cum. Insulation material to be fire retardant. Joining tapes & low VOC adhesive to be supplied with the insulation material by the insulation material manufacturer. , Supply, installation and testing of Class- O, 13 mm thick Closed cell elastomeric insulation for thermal insulation for indoor supply air / return air ducts with density not less than 50 kg / cum. Insulation material to be fire retardant. Joining tapes & low VOC adhesive to be supplied with the insulation material by the insulation material manufacturer. Refer method statement in technical specification for insulation works. , Acoustic Insulation for ducts , Supply, transportation , Lifting , Shifting ,installation ,testing and commissioning of Acoustic insulation for ducting with 50mm TF quality thermocole, density 18kg/cum, chicken wire mesh and 2 coats of 12mm thick sandcement plastering for exposed ducting. , Air Terminal Devices , Supply, installation, testing and balancing Powder Coated extruded aluminium grilles with collar damper for supply and return distribution(colour for the grill to be confirmed by department before placing theorder) . Deflection of the grille shall be 0 / 15 / 30. same will be confirmed later. Single / 2 way / 4 way deflection shall be confirmed later. , Supply, Fixing, Testing and commissioning of Aluminium powder coated4-Way Diffusers with Anti smudge ring and all fixing accesseroies as per standard specifications and practice. , Supply, installation and testing ofJet diffuserwith fire resistance flexible double canvas Connection for supply distribution(colour for the Jet to be confirmed by consultant/ PMC team before placing theorder) , Ø 315 , Supply and fixing of 18G circular butterfly damper with provision to fix to the rectangular duct with GI circular flanges. , Supply and fixing of Insulated Aluminum flexible duct with 25mm thick glass wool insulation covered with aluminum foil suitable to connect the ducting including necessary clamps at both ends of size , Acoustic Insulation for AHU rooms , Supply, installation and testing of acoustic insulation on walls & ceilings for the AHU Rooms with 50mm thk. 24 kg/ cum density Resin bonded fiber glass covered with 24 G GI perforated sheet as per specification. The FG slabs shall be placed in the grid of 600mmx600mm centers formed out of GI channels. , Supply and Fixing of Fresh Air / Exhaust air Louvers with brass wire mesh backing with Pre filter along with Dampers for all AHU room fresh air wall openings. , Supply, installation and testing of Factory fabricated Rectangular shape - GI Volume control dampers, 1.6-mm GI Steel Frame, 1.6-mm GI blades, 150-mm width, with required hardware and accessories. Stiffen damper blades for stability. Include locking device to hold single-blade dampers in a fixed position without vibration & engraved marking on position of damper. , Supply, installation and testing of Aluminium powder coated fresh air intake / exhaust air louvers backing with pre filters complete with HDPE insect mesh with cowl mounting frame and 45 deg angle suitable for protection against splashing rain water fixed in a powder coated Aluminium angle mount frames as required for all AHU ROOM fresh air wall openings. , Supply, installation and testing of Motorized Fire dampers (MSFD) with ON/OFF type actuator. The dampers to be fire rated for 120 minutes at 250Deg C. Fire damper to be provided with matching flanges on both sides. Fire dampers should be supplied with extended fire rated sleeves. Actuators shall be for spring return type & shall be fire rated for 120 minutes @ 120Deg C. Actuators to be internally mounted. Actuators should be suitable for BMS connectivity with necessary accessories. , Note:Duly factory fitted and tested at manufacturers works and certificate to this effect produced along with delivery of fire damper. , Fire damper , Actuator,Sensor,Control panel and relay/communication module, interlinking cabling , Supply, installation and testing ofGI Non ReturnDampersat suction & discharge side, suitable for duct mounted including mating galvanized angular iron flanges. , Supply, Installation, Testing and Commissioning of Fire Retardant Canvass Connections with MS Eoxy painted / Al powdercoated finish angle flanges on both sides as per the specifications and approved drawings. , Supply, installation, testing and commissioning of FM approved 32mm thickness of closed cell nitrile rubber without aluminium foil temperature range from -10ºC to +60ºC, Class O fire category and as per specification.for Underdeck insulation, as per technical specifications and as shown in approved drawings. Adhesive shall be used as recommended by insulation manufacturer for applying over concrete structures and it shall be green building complaint. Makes: Galaxy, sheth insulation, ALP Aeroflex,neothermalinsulation. , MS structural Steel for supports ofUnit, Piping, Control cabling supports including fabrication,erection with GI clamps and brackets with adequate number of supports for pipes every 2.5 mts interval and at bends for Insulated refrigerant pipe for exposed areas etc , FALSE CEILING WORK , Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre,shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. , wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint , all as per manufacturers specification and also including the cost of making openings for light fittings, grills,diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : (a)12.5 mm thick tapered edge gypsum moisture resistant board. (Make : Gproc , L Strong , Armstrong) , ELECTRICAL WORKS: , MV Panels VRF/VRV OUTDOOR PANNEL-1 , Supply, installation,Testing and Commissioning of 3 phase and Neutral 415V, 4 wire Free Standing Floor mounted MV panel made out of 14 SWG MS sheet after seven tank process and painting with Epoxy powder coating. , The panel shall consist of suitable rating TPN Aluminium busbar (at the rating of 0.8A/Sq.mm) supported with DMC/ SMC barriers and color coded with Heat shrinkable sleeves. , The Metering shall be provided as specified. The panel shall have Short circuit withstanding capacity of minimum 50KA and consist of the switchgear as mentioned below. , The panel shall be got fabricated from manufacturers with CPRI Test certificate only. The PCC shall have at least two spare cubicles of the maximum rating. The size of all Panel Mounting Meters shall be 96X96mm. , The Panels shall be mounted on U channels including supply and fixing of the same. Every ACB shall be provided with ON/OFF /Trip Indication lamps of LED type. For all Electrically operated Breakers, Local Remote Selector switches shall be provided for controlling the Breakers remotely. , M.V.PANEL ( OUTDOOR ) -VRF OUTDOOR UNIT , Incoming : 800A FP 50KA EDO ACB with Microprocesser Based releases for Overload, S/Cand earth fault- 1 set , BUSBARS : 800A, TPN Aluminium busbars – 1set , Metering for Incomer , Phaseindicating lamps - 1 set withtoggle switch , Voltmeter (0-500V) with selector switch - 1 set , Ammeter (0-800A) with selector switch - 1 set , Multifunction Meter -1Set , 800/5A, CL-1, 15VA CTs with resin cast- 3Nos. , Outgoing Feeders :- , 63A TP 16KA MCCB As Outgoing Feeder - 18 Nos , Earth bus bar with GI Strip , MV Panels VRF/VRV OUTDOOR PANNEL-2 , Supply, installation, Testing andCommissioning of 3 phase and Neutral415V 4 wire Free Standing Floor mounted outdoor type weather proof double door with canopy on top MV panel made out of 3mm thick CRCA/Galvanised steel enclosurefor main frame and 2mm thick partitions for mechanical strength/ruggedness, after seven tank process and painting with Epoxy powder coating. The panel shall consist of suitable ratingTPN Aluminium busbar (at the rating of 0.8A/Sq.mm) supported with DMC/ SMCbarriers and color coded with Heat shrinkable sleeves. The Metering shall beprovided as specified. The panel shall have Short circuit withstanding capacity of minimum 50KA and consist of the switchgear as mentioned below. Outdoor panels shall have IP-55 degree of protection wiith external door . Enclosure shall be modular with bolted design. Enclosure shall be powder coated with RAL-7035 coat with matt finish. Design ambient temperature shall be 50 degree centrigrade. No use of hygroscopic material like FRP/Hylam/Bakellite sheet inside the panel for partitions or any other purpose. , The PCC shall have at least twospare cubicles. The size of all Panel Mounting Meters shall be 96X96mm. The Panels shall be mounted on U channels including supply and fixing of the same. Every ACB shall be provided with ON/OFF /Trip Indication lamps of LED type. For all Electrically operated Breakers, Local Remote Selector switches shall be provided for controlling the Breakers remotely.ACBs shall have built-inAll ACBs shall be provided with Digital type Ammeter of suitable range along with CTs. All ACBs shall be provided with ON/OFF/TRIP indication lamps and shunt trip coils. All MCCB/ACBs of rating 160Aand above shall be with Micro processor releases All MCCBs below 160A shall be with adjustable thermal magnetic based releases. All MCCBs shall be with spreader links and rotary handle. All MCCBs shall be over load & short circuit releases withIcu=100% Ics. All CTs/CBCT shall be resin cast type. All Controlling wiring shall be FRLS cables, all the bus bar sleeves shall be Heat shrinkable kits.Panels shall have form 4b/form 3b construction as per the requirement. ACBs shall conform to IEC 60947 (part 1&2), shall be suitable for rated system voltage 690V, Insulation voltage 1000V and Impulse withstand of 12KV. , For MCCB with Microprocessor based release : A common indication LED for internal temp/ fault/alarm . MCCB should have in-built feature of logical selectivity by which it can give a time delay of 50msec between upstream and downstream MCCB The microprocessor based release should have the following settings: • Overload Settings: 0.4 to 1 times of Ir • Short Circuit Settings: 1.25 to 10 times of Ir. • Earth fault Settings: 0.2 to 1 times of In. • Neutral protection settings: 0 – 50% – 100%Ir. • Manually closing mechanism should be accommodated in a Moulded housing of robust and vermin-proof construction. • MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open) • The tripping devices shall be ambient temperature compensated type. The insulating case shall be made of high strength heat resistant and flame retardant thermosetting insulating material. , OUTDOOR MAIN PCC PANEL , Incoming : , Incoming : 800A FP 50KA EDO ACB with Microprocesser Based releases for Overload, S/Cand earth fault- 1 set , Busbars :800A TPN Aluminiumbusbars - 1 set , Outgoings : , 63A TPN, 16kA,Moulded Case Circuit Breakerand Electromagnetic based protection release having adjustable over load, short circuit and earth fault protection.- 20 No. , Metering : , 0-500V Digital Voltmeter withselector switch and Fuses - 2 sets , 0-800A Digital Ammeter with CTs ofratio 800/5A,Class 1 Accuracy and15VA burden and selector switch - 2sets , LED Phase indication lamps with individuals Fuses and control withtoggle switches- 2sets , CT Operated Load Manager with RS 485 port ( Similar to EM-6400) – 2sets , Suitable Earth strip at bottom of the panel of GI Strip , Supply, Installation, Testing and Commissioning of following size 1.1 KV Grade Aluminum / Copper conductor XLPE insulated PVC sheathed armoured cable and shall be laid on cable traywith all installation materials. the cable shall conform to IS 7098 / part-I. , 4Core X 10Sqmm (Copper)(Armoured) (for 20HP ODU ) - 27Nos , 4Core X 10Sqmm (Copper)(Armoured) (for 28TR AHU ) - 1Nos , 4Core X 6Sqmm (Copper)(Armoured) (for 8KW HEATER ) - 1Nos , 4Core X 16Sqmm (Copper)(Armoured) (for 52TR AHU ) - 1Nos , 4Core X 10Sqmm (Copper)(Armoured) (for 12KW HEATER ) - 1Nos , 4Core X 16Sqmm (Copper)(Armoured) (for 42TR AHU ) - 4Nos , 4Core X 10Sqmm (Copper)(Armoured) (for 15KW HEATER ) - 4Nos , Supply, Installation, Testing and Commissioning of following size ELECTRICAL TERMINATIONS WITH SINGLE COMPRESSION GLANDS / LUGS: , 4Core X 10Sqmm (Copper)(Armoured) (for 20HP ODU ) - 27Nos , 4Core X 10Sqmm (Copper)(Armoured) (for 28TR AHU ) - 1Nos , 4Core X 6Sqmm (Copper)(Armoured) (for 8KW HEATER ) - 1Nos , 4Core X 16Sqmm (Copper)(Armoured) (for 52TR AHU ) - 1Nos , 4Core X 10Sqmm (Copper)(Armoured) (for 12KW HEATER ) - 1Nos , 4Core X 16Sqmm (Copper)(Armoured) (for 42TR AHU ) - 4Nos , 4Core X 10Sqmm (Copper)(Armoured) (for 15KW HEATER ) - 4Nos , SITC of GI Earthing for equipment , 8 SWG G.I. Wire , SUBHEAD-IVX : POWER WIRING : , Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powderpainted including earthing etc. as required. (But without MCB/RCCB/Isolator) , 12 way (8 + 36), Double door , 8 way (8 + 24), Double door , Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuitbreaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. , 63A , Supplying and fixingof 6A to 32A rating 240/415V,10kA , C Curveminiature circuit breaker suitable for inductive load of following polesin the existing MCB DB complete with connections ,testing and commissioning etc complete. , Single Pole , Supplying and fixing following way, vertical type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powderpainted including earthing etc. as required. (But without MCB/RCCB/Isolator) , 12 way (4 + 24), Double door , 8 way (4 + 24), Double door , Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, molded case circuitbreaker (MCCB), having a breaking capacity 25 KA in the existing MCB DB complete with connections, testing and commissioning etc. as required. , 200A 4P MCCB, 35 kA , Supplying and fixingof following rating 240/415V,10kA , C Curveminiature circuit breaker suitable for inductive load of following polesin the existing MCB DB complete with connections ,testing and commissioning etc complete. , 63A Three Pole MCB 16 kA , Supply,erection,testing and commissioning of the following switchsockets with anodised G.I. Box,front plate and fixing screws etc . , 6/16 Amps, 5-pin (250 Volts) single phase modular type socket controlled by 16 Amps SP Switch. , Supply and fixing of factory made 20A, 1Ph Metalclad socket with plugtop &20A SPMCB in MS box including all fixing accessories , Supply and fixing of factory made 25A, 1Ph Metalclad socket with plugtop &25A SPMCB in MS box including all fixing accessories , Supplying and fixing 32A, 415V, TPN industrial type socket outlet with 4 pole and earth metal enclosed plug top alongwith 32A C Curve, TP MCB in sheet metal enclosure on surface/recess with chained metal cover for the socket outlet and complete with connections ,testingand commissionining etc complete as required. , Supplying and fixing 63A, 415V, TPN industrial type socket outlet with 4 pole and earth metal enclosed plug top alongwith 63A C Curve, TP MCB in sheet metal enclosure on surface/recess with chained metal cover for the socket outlet and complete with connections, testingand commissionining etc complete as required. , Supply,erection,testing and commissioning of the following switchsockets with anodised G.I. Box, Stainless steel front plate and fixing screws etc . , 6/16 Amps, 5-pin (250 Volts) single phase modular type socket controlled by 16 Amps SP Switch. , Supply and Wiring with the following size 1100V grade PVC insulated multistrand, FRLS Copper conductor wires in and includingsuitable size heavy gauge PVC conduit concealed in wall / Ceiling including all accessories such as junction boxes, bends, elbows including end terminated with suitable lugs. , 2runs of 4Sq.mm wires with 1run of 4 Sq.mm wireinand including 25mm diaPVC Conduit(For 16A Sockets). , 2runs of 6Sq.mm wires with 1run of 6 Sq.mm wireinand including 25mm diaPVC Conduit(For AC Sockets). , 4runs of 10Sq.mm wires with 2run of 6 Sq.mm wireinand including 25mm diaPVCConduit. , 4 X 16 sq. mm + 2 X 16 sq. mm earth wire in existin PVC / Floor raceways , Supply and Wiring with the following size 1100V grade PVC insulated multistrand, FRLS Copper conductor wires in existingMS/PVC conduit / Floor race way including all necessary interconnections etc complete. , 2runs of 2.5Sq.mm wires with 1run of 2.5 Sq.mm wire in existingPVC Conduit(For 6A Sockets & Switch boards),ferrules incliding all labour charges etc., complte.. , 2runs of 4Sq.mm wires with 1run of 4 Sq.mm wiresin existingPVC Conduit(For 16A Sockets), ferrules incliding all labour charges etc., complte.. , 2runs of 6Sq.mm wires with 1run of 6 Sq.mm wiresin existing PVC Conduit(For AC Sockets), ferrules incliding all labour charges etc., complte.. , 4runs of 6Sq.mm wires with 2run of 6 Sq.mm wiresin existing PVC Conduit. for run of mains, ferrules incliding all labour charges etc., complte. , 4runs of 10Sq.mm wires with 2run of 6 Sq.mm wireinexistingPVCConduit.for run of mains, ferrules incliding all labour charges etc., complte. , 4 X 16 sq. mm + 2 X 16 sq. mm earth wire in existin PVC / Floor raceways for run of mains, ferrules incliding all labour charges etc., complte. , Providing and fixing of maintenance free earthing which consists of 40mm Dia, standard length (as per Equipment Supplier) electrode capsule,filled with earth enhancing compound,sealed at both ends and brazed lead for connection at one end suitable for direct installation at site at a depth of 2.5 mtr.Earth enhancingcompound upto a depth of 2.0 mtr around the electrode capsule and also wih brick chamber and cast Iron cover etc complete including excavation in all types of soil. , Supply and laying of following size strips including all necessary inter connections with earth station and equipments , 50 X 5 mm Hot dip GI strip , 25 X 5 mm Hot dip GI strip , Supplying and laying 6 SWG G.I. wire at 0.50 meter below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. , Supply and fixing of following size GIPerforated type cable tray made out of 2mm thick G.Isheet including MS supports for fixing the tray, anchor fasteners etc., laid including 2runs of 25x5 GI strip etc including with 2 mm thickGI covers. , 300 mm widex 50 mm Height , 150 mm widex 50 mm Height , 100 mm widex 50 mm Height , Supply, laying, jointing GI pipes of medium quality including specials of approved make fixed to wall/to the required lengths, threading jointing chasing the walls and floor, making holes, clamping of clamps and making good the same, necessary excavation, etc., complete as specifed and directed. , 50mm Dia , SUBHEAD-XV : SHOP ELECTRIC: , Supplying and fixing 20A, 415V, TPN industrial typesocket outlet with 4 pole and earth metal enclosed plug top alongwith 20A C Curve,4 P MCB in sheet metal enclosure on surface/recess with chained metal cover for the socket outlet and complete with connections ,testingand commissionining etc complete as required. , Supplying and fixing 32A, 415V, TPN industrial type socket outlet with 4 pole and earthalongwith 32A C Curve, TP MCB in sheet metal enclosure on surface/recess with chained metal cover for the socket outlet and complete with connections ,testingand commissionining etc complete as required. , Supplying and fixing 63A, 415V, TPN industrial type socket outlet with 4 pole and earthalongwith 63A C Curve, TP MCB in sheet metal enclosure on surface/recess with chained metal cover for the socket outlet and complete with connections ,testingand commissionining etc complete as required. , Supply, testingand commissioning of following size 1.1KV grade XLPE insulated armoured aluminium conductor cable. The cable shall conform to IS 7098/ Part-II. , 4C X 10Sq.mm , 4C X 16Sq.mm , 3.5C X 25Sq.mm , 3.5C X 35Sq.mm , 4C X 50Sq.mmCu Armoured Cable , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. , Upto 35 sq. mm , Above 35 sq. mm and upto 95 sq. mm , Above 95 sq. mm and upto 185 sq. mm , Above 185 sq. mm and upto 400 sq. mm , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. , Upto 35 sq. mm , Above 35 sq. mm and upto 95 sq. mm , Above 95 sq. mm and upto 185 sq. mm , Above 185 sq. mm and upto 400 sq. mm , Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. , Upto 35 sq. mm , Above 35 sq. mm and upto 95 sq. mm , Above 95 sq. mm and upto 185 sq. mm , Above 185 sq. mm and upto 400 sq. mm , Providing Indoor ordinary end terminations for thefoollwing 1.1 KV grade XLPE insulated armoured alluminium conductor cables with compression type steel gland, Bi-metallic lugs using crimping tool, Insulation tape, Identification tags etc., including end termination and Earthing of Gland with 8SWG GI Wire. , 4C X 10Sq.mm , 4C X 16Sq.mm , 3.5C X 25Sq.mm , 3.5C X 35Sq.mm , 4C X 50Sq.mmCu Armoured Cable , Supply and fixing of following size GIPerforated type cable tray made out of 2mm thick G.Isheet including MS supports for fixing the tray, anchor fasteners etc., laid including 2runs of 25x5 GI strip etc including with 2 mm thickGI covers. , 600 mm widex 50 mm Height , 450 mm widex 50 mm Height , 300 mm widex 50 mm Height , 150 mm widex 50 mm Height , Providing and fixing of maintenance free earthing which consists of 40mm Dia, standrad length (as per Equipment Supplier) electrode capsule,filled with earth enhancing compound,sealed at both ends and brazed lead for connection at one end suitable for direct installation at site at a depth of 2.5 mtr.Earth enhancingcompound upto a depth of 2.0 mtr around the electrode capsule and also wih brick chamber and cast Iron cover etc complete including excavation in all types of soil. , Supply and laying of following size strips including all necessary inter connections with earth station and equipments. , 50 X 5 mm Hot dip GI strip , 25 X 5 mm Hot dip GI strip , Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. , Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCBdistribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs andincomer ) as required . (Note : Vertical type MCB TPDB isnormally used where 3 phase outlets are required.) , 12 way (8 + 36), Double door , Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuitbreaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. , 250 A, 35KA 4P MCCB , 200 A, 35KA 4P MCCB , 63 A, 4P RCBO , 100 A, 4P ,25ka MCCB ( , 125 A, 4P ,25ka MCCB ( , Supply,Installation Testing Commissioning of following TTA PANEL.Supply, erection, testing and commissioning of 415V, 3 phase 4 wire 50 c/s Main LT Panel at Substation fully compartmentalized cubical type, as per the standards IEC61439-1&2 as tested assembly (TTA) ,tested for impulse voltage 8 KV,IP 42 fabricated CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having required capacity extensible type FP bus bars of high conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 35KA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, Form of separation shall be form 4b with metallic separation only entire panel shall have a common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of bus bars, interconnection, interlocking between feeders etc.,with indication lamps, push buttons necessary accessories, complete with following incoming and outgoing switchgears with protection and metering etc. as per specification and schematic diagram including provision to be made for interfacing with BMS etc. complete as required, with incoming & outgoing cable entry from bottom/top and bus-duct entry from top, wiring with 2.5sq. mm. FRLS insulated copper conductor , cable alleys, PLC cable gland i/c providing following switch gears , All ACBs should have Ics=Icu=Icw for 1 sec All MCCBs shall be rating for 25kA (Ics=Icu). All MCCBs above 63A should be provided with Copper Spreader Terminals Marshalling Bay To Be Provided for BMS Operation Approval shall be taken for each panel before fabrication. PLC based control with 100% hot redundant PLC arrangement with touch-screen LCD / LED display board (min. 8 Diag size)along with all accessories for complete automatic, manual andHMI controls & indication. Energy Management Software wth necessary cabling shall be in scope, nos. of breaker / Meters to be connect with energy management software shall be inform by Engineer In Charge. , USER EQUIPMENT PANEL , Incomer , 630 A, 50KA, 4P , ACB, Should be supplied with Microprocessor basedS/C, E/F, O/CProtection.(70 - 100% Plug setting) – 1No , 2A, controlMCB - 3 Nos. , Outgoings : , 200A ,35KA TP, MCCBs - 9 Nos , 125A ,25KA TP, MCCBs - 3 Nos , 100A ,25KA TP, MCCBs - 3 Nos , 63A ,16KA TP, MCCBs - 3 Nos , Surge Protection Device - 1 No , Bus Bar : 630 A TPN Alluminium Bus Bar-1 Set , MeteringIncomer : , 0-500V Digital Voltmeter with selector switch andMCB-1set , CT Operated Load Manager (similar to EM-6400) - 1 No , 0-630A Digital Ammeter with resin cast CTsof ratio 630/5A Class 1 Accuracy and 15VA burden and selector switch -1set , LED phase indication lamps with toggle switch -1set , Main LDB , Incomer , 250 A, 35KA, 4P , MCCB, Should be supplied with Microprocessor basedS/C, E/F, O/CProtection.(70 - 100% Plug setting) – 1No , 2A, controlMCB - 3 Nos. , Outgoings : , 160A ,35KA TP, MCCBs - 5 Nos , 63A ,16KA TP, MCCBs - 2 Nos , Surge Protection Device - 1 No , Bus Bar : 250 A TPN Alluminium Bus Bar-1 Set , MeteringIncomer : , 0-500V Digital Voltmeter with selector switch andMCB-1set , CT Operated Load Manager (similar to EM-6400) - 1 No , 0-250A Digital Ammeter with resin cast CTsof ratio 250/5A Class 1 Accuracy and 15VA burden and selector switch -1set , LED phase indication lamps with toggle switch -1set , Main PDB , Incomer , 630 A, 50KA, 4P , MCCB, Should be supplied with Microprocessor basedS/C, E/F, O/CProtection.(70 - 100% Plug setting) – 1No , 2A, controlMCB - 3 Nos. , Outgoings : , 200A ,35KA TP, MCCBs - 5 Nos , 63A ,16KA TP, MCCBs - 2 Nos , Surge Protection Device - 1 No , Bus Bar : 630 A TPN Alluminium Bus Bar-1 Set , MeteringIncomer : , 0-500V Digital Voltmeter with selector switch andMCB-1set , CT Operated Load Manager (similar to EM-6400) - 1 No , 0-630A Digital Ammeter with resin cast CTsof ratio 630/5A Class 1 Accuracy and 15VA burden and selector switch -1set , LED phase indication lamps with toggle switch -1set , COMPRESSOR PANEL , Incomer , 250 A, 35KA, 4P , MCCB Should be supplied with Microprcessor basedS/C, E/F, O/CProtection.(70 - 100% Plug setting) – 1No , 2A, controlMCB - 3 Nos. , Outgoings : , 160A ,25KA TP, MCCBs – 3 Nos , 63A ,16KA TP, MCCBs - 1 Nos , 40A ,16KA TP, MCCBs - 1 Nos , Surge Protection Device - 1 No , Bus Bar : 250 A TPN Alluminium Bus Bar-1 Set , MeteringIncomer : , 0-500V Digital Voltmeter with selector switch andMCB-1set , CT Operated Load Manager (similar to EM-6400) - 1 No , 0-250A Digital Ammeter with resin cast CTs of ratio 250/5A Class 1 Accuracy and 15VA burden and selector switch -1set , LED phase indication lamps with toggle switch -1set , SUBHEAD-XVI :TELEPHONE AND LAN : , Supply and laying of 25mm dia, 16 SWG black enamelled M.S. conduit concealed in wall/ ceiling/ floor including all accessories such as junction boxes, conduit bends, etc., complete as required for Telephone etc., , Supply and laying of 25mm dia, heavy gaugePVC . conduit concealed in wall/ ceiling/ floor including all accessories such as junction boxes, conduit bends, etc., complete as required for Telephone etc., , Supply and laying of 25mm dia, heavy gaugePVC . conduit concealed in wall/ ceiling/ floorand drawing of 12 SWG GI Wireas fish wire for laying of LAN Cables at a later stage and supply of all fixingaccessories such as junction boxes, conduit bends, etc., complete as required. , Supply and fixing of Telephone outlet (RJ11) with anodised GI box with front plate and fixing screws. , Supply,Installation,Testing and commissioning ofRJ 45 socket(FOR LAN) with flush mounting G.I. box, with front plate and fixing screws etc complete. , Supply and laying of 2pair 0.5mm dia PVC insulated Copper conductor Telephone wireconforming to DOT Specifications in already laid PVC Conduit including necessary interconnections. , Supply and laying of Cat 6 LAN cable conforming to DOT Specifications in already laid PVC Conduit Floor Race way including necessary interconnections. , Supply and laying of 10 Pair0.5 sqmm armoured copper conductor cable cable conforming to DOT Specifications in existing cable trench /Floor Race way including necessary interconnections. , Supply and installation of100 pair Krone connectors inMS junction box complete as required. , Supply and installation of50 pair Krone connectors inMS junction box complete as required. , Supply and installation of20 pair Krone connectors inMS junction box complete as required. , Supply, laying, jointing GI pipes of medium quality including specials of approved make fixed to wall/to the required lengths, threading jointing chasing the walls and floor, making holes, clamping of clamps and making good the same, necessary excavation, etc., complete as specifed and directed. , 50mm Dia , SUBHEAD-XVII :UPS WIRING : , Supply and fixing of2 Nos of 6/16A, 5Pin Socket outlet with 2Nos ofswitch of 16A ratingincluding Modular G.I Box, Front Plate and also including all fixing accessories etc complete. ( For UPS Socket) , 6/16 Amps, 5-pin (250 Volts) single phase modular type socket controlled by 16 Amps SP Switch including Modular G.I Box, Front Plate and also including all fixing accessories etc complete. , Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCBdistribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs andincomer ) as required . (Note : Vertical type MCB TPDB isnormally used where 3 phase outlets are required.) , 4 way (4 + 12), Double door , Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, molded case circuitbreaker (MCCB), having a breaking capacity 25 KA in the existing MCB DB complete with connections, testing and commissioning etc. as required. , 200A 4P MCCB, 35 kA , Supplying and fixingof following rating 240/415V,10kA , C Curveminiature circuit breaker suitable for inductive load of following polesin the existing MCB DB complete with connections ,testing and commissioning etc complete. , 63A 4P MCB 10 kA , 63A TPN MCB 10 kA , Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powderpainted including earthing etc. as required. (But without MCB/RCCB/Isolator). , 8 way (8 + 24), Double door , Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuitbreaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. , 63 A , Supplying and fixingof 6A to 32A rating 240/415V, 10kA, C Curveminiature circuit breaker suitable for inductive load of following polesin the existing MCB DB complete with connections, testing and commissioning etc complete. , Single Pole , Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copperconductor, single core cable in surface/ recessed medium class PVC/MS/Floor race wayas required including necessary interconnections etc complete. , 2runs of 4Sq.mm wires with 1run of 4 Sq.mm wire , 4Runs X 10 sq. mm + 2 X 6 sq. mm earth wire in existing PVC / Floor raceways /MS Conduit , 4Runs X 16 sq. mm + 2 X 10 sq. mm earth wire in existing PVC / Floor raceways , Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt asrequired including excavation in all types of soil. , Supplying and laying following copper strip at 0.50 metre below ground as strip earth electrode, includingconnection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets(Jointing shall be done by overlapping and with 2 setsof brass nut bolt & spring washer spaced at 50mm). , 25 mm X 5 mm copper strip , 50 x 5 mm copper stripbelow ground. , Supply and Installationof 300 x 38 mm heightG.I Floor raceway including supply and installation ofJunction Boxes ,bends and fixing accessories etc complete.The scope also includes civil work for installation of Raceways i.e chipping of flooe wherever required and also laying of sand and cement mortar for alignment of Floor raceways etc complete.The minimum thickness of the floor raceways and junction boxes shall be 2 mm (Make : Legrand ) , Supply and Installationof 150 x 38 mm heightG.I Floor raceway including supply and installation ofJunction Boxes ,bends and fixing accessories etc complete.The scope also includes civil work for installation of Raceways i.e chipping of flooe wherever required and also laying of sand and cement mortar for alignment of Floor raceways etc complete.The minimum thickness of the floor raceways and junction boxes shall be 2 mm (Make : Legrand ) , Supply,Installation Testing Commissioning of following TTA PANEL.Supply, erection, testing and commissioning of 415V, 3 phase 4 wire 50 c/s Main LT Panel at Substation fully compartmentalized cubical type, as per the standards IEC61439-1&2 as tested assembly (TTA) ,tested for impulse voltage 8 KV,IP 42 fabricated CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having required capacity extensible type FP bus bars of high conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 35KA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, Form of separation shall be form 4b with metallic separation only entire panel shall have a common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of bus bars, interconnection, interlocking between feeders etc.,with indication lamps, push buttons necessary accessories, complete with following incoming and outgoing switchgears with protection and metering etc. as per specification and schematic diagram including provision to be made for interfacing with BMS etc. complete as required, with incoming & outgoing cable entry from bottom/top and bus-duct entry from top, wiring with 2.5sq. mm. FRLS insulated copper conductor , cable alleys, PLC cable gland i/c providing following switch gears All ACBs should have Ics=Icu=Icw for 1 sec All MCCBs shall be rating for 25kA (Ics=Icu). All MCCBs above 63A should be provided with Copper Spreader Terminals Marshalling Bay To Be Provided for BMS Operation Approval shall be taken for each panel before fabrication. PLC based control with 100% hot redundant PLC arrangement with touch-screen LCD / LED display board (min. 8 Diag size)along with all accessories for complete automatic, manual andHMI controls & indication. Energy Management Software wth necessary cabling shall be in scope, nos. of breaker / Meters to be connect with energy management software shall be inform by Engineer In Charge. , UPS INPUT PANEL INDOOR , Incomer , 200 A, 35KA, 4P, MCCB Should be supplied with S/C, E/F, O/CProtection.(70 - 100% Plug setting) – 1No , 2A, controlMCB - 3 Nos. , Outgoings : , 100A ,25KA 4P, MCCBs - 3 Nos , Surge Protection Device - 1 No , Bus Bar : 200 A TPN(100%)Alluminium Bus Bar-1 Set , MeteringIncomer : , 0-500V Digital Voltmeter with selector switch andMCB-1set , CT Operated Load Manager (similar to EM-6400) - 1 No , 0-200A Digital Ammeter with resin cast CTsof ratio 200/5A Class 1 Accuracy and 15VA burden and selector switch -1set , LED phase indication lamps with toggle switch -1set , UPSOUTPUT PANEL INDOOR , Incomer , 200 A, 35KA, 4P , MCCB, Should be supplied with S/C, E/F, O/CProtection.(70 - 100% Plug setting) – 1No , 2A, controlMCB - 3 Nos. , Outgoings : , 63A ,10KA 4P, MCCBs - 5 Nos , Bus Bar : 200 A TP+NAlluminium Bus Bar-1 Set , MeteringIncomer : , 0-500V Digital Voltmeter with selector switch andMCB-1set , CT Operated Load Manager (similar to EM-6400) - 1 No , 0-200A Digital Ammeter with resin cast CTsof ratio 200/5A Class 1 Accuracy and 15VA burden and selector switch -1set , Surge Protection Device - 1 No , Supply, testingand commissioning of following size 1.1KV grade XLPE insulated armoured aluminium conductor cable. The cable shall conform to IS 7098/ Part-II. , 4C X 50Sq.mmCu Armoured Cable , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. , Above 35 sq. mm and upto 95 sq. mm , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. , Above 35 sq. mm and upto 95 sq. mm , Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. , Above 35 sq. mm and upto 95 sq. mm , Providing Indoor ordinary end terminations for thefoollwing 1.1 KV grade XLPE insulated armoured alluminium conductor cables with compression type steel gland, Bi-metallic lugs using crimping tool, Insulation tape, Identification tags etc., including end termination and Earthing of Gland with 8SWG GI Wire. , 4C X 50Sq.mmCu Armoured Cable , SUBHEAD-XVIII : SPECIAL EARTHING : , Providing and fixing of maintenance free earthing which consists of 65 MM Dia ,2.5mtr long electrode capsule,filled with earth enhancing compound,sealed at both ends and brazed lead for connection at one end suitable for direct installation at site at a depth of 2.5 mtr.Earth enhancingcompound upto a depth of 2.0 mtr around the electrode capsule and also wih brick chamber and cast Iron cover etc complete including excavation in all types of soil. , Supply and laying under ground/above ground offollowing size strips including all necessary interconnections between earth station and equipments including earth excavation, back filling, intermediate supports for strips as applicable and directed by engineer in charge. , 25 x 3 mm copper strip on DMC insulators , 25 x 3 mm copper stripbelow ground. , 50 x 5 mm copper stripbelow ground. , Supply and fixing of Static Discharge Handles made out of 40 mm dia Copper rod 600 mm Long fixed on wall with brass spacers and connected to 25 x 3 mm copper strip by brazing. , Supply, laying, jointing GI pipes of medium quality including specials of approved make fixed to wall/to the required lengths, threading jointing chasing the walls and floor, making holes, clamping of clamps and making good the same, necessary excavation, etc., complete as specifed and directed. , 50mm Dia , SUBHEAD-XIX : LIGHTNING PROTECTION : , Providing and fixing of maintenance free earthing which consists of 40mm Dia ,standrad length (as per Equipment Supplier ) electrode capsule,filled with earth enhancing compound,sealed at both ends and brazed lead for connection at one end suitable for direct installation at site at a depth of 2.5 mtr.Earth enhancingcompound upto a depth of 2.0 mtr around the electrode capsule and also wih brick chamber and cast Iron cover etc complete including excavation in all types of soil. , Supply and laying of following sizestripsincluding all necessary inter connectionsbetween earth station and equipment. supports for strips as applicable and directed by engineer in charge. , 32 X6 mm Aluminiumstrip conductor with DMC Insulator Supports , 50 X 5 mm GI strip conductor including excvation and back filling. , 25 X 5 mm Hot dip GI strip , Supply and installation of vertical air termination with 100mm dia copper hollow sphere with spikes, fixed on 1500mm length 50mm dia Class C GI pipe including all fixing accessories. , Providing and fixing of Test links for Lightning protection system. , SUBHEAD-XX: FIRE ALARM SYSTEM : , Supply, erection, testing and commissioning of Intelligent AddressableFire Alarm Control Panel(a minimum of 159 detectors/ 159 modules per loop )with Network Communication Module expandable to 2 loop, to monitor loop Devices located in allfloor with dual stage alarm facilities,built in buzzer,built in NAC Circuits & RS 485 port on CPU boardwith optional net work software connectivity, fire/fault indicators, audio-visual signals, battery, battery charger, central processing unit,80 character display unit,fibre optic converter and networking card etc complete in all respects . , 2 - Loop Panel ( One Loop for Integration ) , Supplying, installation, testing & commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches etc complete. , Supply, Installation, Testing and commissioning of Online UPS of 1 KVA capacity with built-in SMF Batteries (12V 7Ah X 3nos) for battery back up and regulated AC supply to the FAS. , COMIBINATION/MULTI SENSOR DETECTORS(Photoelectric + Heat Sensing) , Supply, fixing, testing and commissioning of Addressable anloguetype multi sensor detectors (Photo electric + Heat sensing) with dual chamber, solid state design,Rotatable DIP Switch Setting indicating lamp, mounting base etc. . , Supply, fixing, testing and commissioning of Response Indicators with all required accessories etc complete. , Supply, fixing, testing and commissioning of Addressable anloguetype Beam Detector with transmitter and receiverincluding short circuit isolator including connections with remote test features etc complete. Range 100 Mtr , MANUAL CALL POINTS: , Supply, erection, testing and commissioning of Addressable analogue typemanual call point for indoor installtion. , Supply, Installation, Testing and commissining of Addressable analogue type manual call point stations weather proofwith 1500 mm Length ISMC 100 standing Post. , FAULT ISOLATION MODULE: , Supply, fixing, testing and commissioning ofFault Isolation module. , Supply, installation, testing & commissioning of addressable fire control module complete as required. , Supply, installation, testing & commissioning of addressable fire Monitormodule complete as required. , CABLE: , Supply, laying , testing and commissioning of 1100 V grade FIRE RESITANCE LOW SMOKE PVC insulatedcopper conductor control cables as per specification. , Armoured Twisted pair2Cx 1.5 sq. mm. shielded FRLS insulated copper conductor cable to be laid on cable tray /to be clamped to wall including supply and fixing of clamps etc complete. , Armoured Twisted pair2Cx 1.5 sq. mm. shielded FRLS insulated copper conductor cable to be laid in cable trench including excavation and backfilling. , 3 core x 2.5 Sq.mm armoured sheilded twisted pair copper conductor cable on cable tray/on wall including clamping etc complete and including cable end termination with double compression weather proof cable glands and copper lugs. , Supply and Installtion of 12 Way Elmex terminal powder Coated junction Boxincluding all terminations andNecessary Glands. , Supply, Installation, Testing and commissioning of Weather proof siren to be operated on Single Phase 230 V, 50 Hz ,A.C.Supply with a range of 2/3 km distance including fixing clamps and accessories.complete. , Supply, laying of 50mm dia, class-B GI pipe including specials of approved make fixed to wall/to the required lengths, threading jointing chasing the walls and floor, making holes, clamping of clamps and making good the same, necessary excavation, etc., complete as specifed and directed. , Supply and laying of of 6 core 9/125 micro meters armored single mode optical fiber cable with suitable dia HDPE pipe (1300nm wave length) including splicing & terminations and laid in ground at 750 mm below ground including excavation andsand, brick protection and refilling of earth and cable route markers at every 50 meters intervals. 6C SM ARM-OFC - 6 C Armoured Single Mode Optical Fiber Cable networking card and fibre optic converter etc., complete. , Supply and laying of 25mm dia, 16 SWG black enamelled M.S. conduit on wall surface/ ceiling/ floor including all accessories such as junction boxes, conduit bends, etc., complete as requiredduly coated with two coats ofred colour enamel paintetc., complete. , SUBHEAD-XXI :FIRE FIGHTING SYSTEM : , Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required : , Single headed Gunmetal , Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze /gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : , 80 mm dia , 150 mm dia , Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required : , 80mm dia , 150mm dia , Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts,washers etc.as required : , 80mm dia , 150mm dia , Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : , Gun Metal , Supply, installtion, testing and commissioning off Hose Box to accommodate 2sets of CP hoses of 15 mtr length each and with 1 pair of Male and female coupling, and one branch pipe with nozzle. The cabinet shall be made of 16 SWG MS Sheet with double door glass front and painted with Scarlet Red colour of size 30x24. , Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : , Gun metal , Supply, Installation, Testing and Commissioning of Swinging type fire hose reel drum of Rubber hose 30mtrs length. , Supplying and fixing of fire brigadeconnectionofcast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : , 4 way - 150 mm dia M.S. Pipe , Providing, laying, testing & commissioning of C class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts,gaskets etc. in ground including welding, as supports, anticorrosive treatment with coaltar/asphalt/bitumen tape as per IS 10221, refilling the trench etc. of following sizes complete as required. , 150 mm dia. Pipe , 80 mm dia. Pipe , 50 mm dia. Pipe , Supply, errect, jointing, testing and commissioning of heavy class MS pipes (as per IS-1239). The pipes being fixed on to the wall or suspended from the ceiling/ truss with angle iron supports complete with bends, tees, flanges and with all other required accessories including painting of the pipeline with two coats of approved enamel paint over a coat of primer etc. complete. , 150 mm dia. , 100 mm dia. , 80 mm dia. , 65 mm dia. , 50 mm dia. , 40 mm dia. , 32 mm dia. , 25 mm dia. , Supply and installation , Testing andcommissioingofapproved make 15mm orifice quartzoid bulb pendent type sprinklers,68°C rating, recessed , Supply and installation, Testing andcommissioingofapproved make 15mm orifice quartzoid bulb side wallpendant type sprinklers,68°C rating. , Supply installation and fixing of flow switchesin the followingPipe line with1NO+1NC Contacts , a)150/100mm dia , Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. , In ordinary soil. , Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m : Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia , Hard rock (blasting prohibited) , Ordinary rock : , Construction valve chamber 1.8 Mtrs x 1.2 Mtrs x 1.2 Mtrs in first classbrick (table moulded) masonry in CM 1:6 on PCC bed to 100mm thick plastering with CM 1:4 internal and providing CI Cover with stiffness lifting arrangement frame work etc. complete with providing anticorrosive paint on both side for steel works.Cover should be in two halfs fixed to frame work by means of hinges. , Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : , 300 mm dia. R.C.C. pipe , Supply, laying, jointing, testing and commissioning heavy class M.S pipe (as per IS-1239) in Pump roomwithMS supports including two coats of red oxide and two coats of Red coloure enamel paint . Rate quoted shall include for necessary specials like long radius bends, tees, including cutting, welding/ flanged joints with necessary washers, nuts, bolts etc., complete. , 250 mm dia. Pipe , 200 mm dia. Pipe , 150 mm dia. Pipe , 100 mm dia. Pipe , 80 mm dia. Pipe , Supply, Installation,Testing and Commissioning of air cussion vessel ofcapacity 250 litreswith air releasevalve and ball valve. , Supply,Installation,Testing and Commissioning of PN 16Sluice valves with gateof the following sizes. , a) 250mm dia , b) 200mm dia , c) 100mm dia , Supply,Installation,Testing and Commissioning of PN 16Butterfly valves of the following sizes including flanges and hardware ,nuts and bolts etc complete. , a) 200mm dia , b) 80mm dia , Supply, Installation, Testing and Commissioning of CI Non Return valves of the following sizes. , a) 200mm dia , b)80mm dia , Supply, installation, testing and commissioning of approved make brass Y strainer with necessary flanges which should include nuts, bolts, washers, gaskets. , a) 200 mm dia. , c) 100 mm dia. , Supply,Installation,Testing and Commissioning ofelectrical control panel for diesel engine, main motor and for jockey pump comprising of following. , Incoming : 800A,50KA TPNMCCB - 1SET , 800A TPN aluminium busbars - 1set , Outgoings: , Main Fire Pump 250 Amp, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 100 hp pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. - 2 sets , (with built in single phase preventor) and ON/OFF/TRIP , indication lamps for motor-2set , Jockey Pump 125 Amp, 50kA TPN MCCB, Ics=100% Icu, with Suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. - 2 sets , Diesel Engine Control , Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0-20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System Controller Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification , Supply installation testing and commissioning of Instrumentation Board on type pressure gauges for pumps in delivery line and common delivery header , Supply fabrication and erection of MS angle supports for Pipe lines , Supply and fixing of G.M. ball type valves Conforming to IS , a) 25mm dia , b) 15mm dia , Supply, Installation, Testing and Commissioning of Pressure Switches. Make: Indfoss/Donfoss , Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS-325. M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered with anti vibration pads. 2280 lpm at 70 m Head with 70% of Pump efficiency. , Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. 2280 lpm at 70 m Head with 70% of Pump efficiency. , Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS : 325. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. 180 lpm at 70 m Head , Supply, Installation of following Fire extinguishers & accessories: , CO2 6.5 kg capacity trolley mounted , CO2 22.5 kg capacity trolley mounted , DCP 5 kg capacity (potassium bi-carbonate Uria reaction) , Water buckets with stand , Sand buckets with stand , Showels , Fire Beater , Fire gong/ hand siren , Ceiling Hook , Supplying, installation, testing & commissioning of 1000 MM sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. , Supplying, installation, testing & commissioning of 1500 MM sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. , Supplying Installation Testing & Commissioning of Ceiling Mountedexit sign/emergency lighting unit uses high-performance led lamps. , Supply installation testing and commissioning of900LPM,35mtrs head Booster pump with Suitable HP 2900 RPM Electrical motor and coupling as per TAC regulations with necessary accessory including base plate of MS channel and suitable reinforced CC foundation with nuts andbolts , Supply, installation, testing and commissioningof weather proof type MPCB box made out of 2mm thick CRCA sheet including painting with epoxypowder coating for Suitable HPBooster pump motor. The box shall be suitable for terminating AYFY cable ofsuitable angle frame work of 450mm height on a PCC pedestal including all materials Outgoings : DOL starter for 15HP with MPCB and contractor, over load relay, single phasing preventor and ON/OFF/TRIP , SUBHEAD-XXII: WATER COLLERS , Supply and fixing of 40 (cooling)/ 80 (storage) ltrswater cooler with water purifier (RO system) and voltage stabilizer etc. complete. , SUBHEAD-XXIII :LIFTS : , Supply, erection, testing and commissioning ofMachine room less gear less 1000Kgs Goods liftwith a speed of 0.75 meters per second,suitable for (Ground + 2floors) floors operation with 3 phase ACVVVF drive of suitable HP to operate on 415 volts 50 HZ with base including 1100X 1300X2300 mm car made of all stainless steel body, heavy duty cabin suitable for one number car entrance and landing entrance doors ( Center operated doors ) , SS hairline finish , with clear opening of 800x2100mmn height suitable for simplex selective and collective operation with or without attendant including call register and other parameters as per specification , SUBHEAD-XXIV : EOT CRANES , Design, Manufacture, supply , erection, testing and CommissioningofTandem operator (1 set consist of 2 nos of cranes)DoubleGirderNon FLPEOT Cranewithall speeds VVVF drivecontrol and micro speed arrangement for hoist, CT & LT and confirming to IS 807/IS 3177 /4137cand other relevant IS standards of the latest revisions as shown below complete with all taxes, duties and other charges such as transportation to site, loading and unloading at stores / building, where to be installed etc., movement of material to work spot including the cost of paint as required loaded testing at factory and at site. The crane shall be designed for earthquake and sesmic qualification.Span to be measured by the the Bidder at Site and it shall be its sole responsibility to provided Spansuitable . Design drawings and list of materail to be submitted to department duly approved checked by Govt., agency/ reputed technical institute as approved by department. VVVF drive controls with along travel andcross travel movement and with pendent control opeartion as per IS807 &IS3177(includingfestool cable, 60 lb rails, third party inspection, transportation, design proof check)Double Girder Box Type. 25% overload ,Duty class- III, head Room 2.5mtr,side clearence 300.indoor operation.AC Control Supply , Floor operated via pendant push button,All drives should be provided with alternative parallel path with DOL starter for Main Speed only , MOTORS- Conformingto IS 325-1978& 900-1965, , GEAR BOX- Electro Hydraulic Thrusters type,3Ph, 440V, A.C. Conforming with IS 3938 - 1983 , WIRE ROPE- 6X 36 Cont. Hempcore(IS 2365-1963) , Rope Drum- made from Seamless/ms rolled , Hook- Forged Material EN-3A , WHEEL ASSEMBLY- Made from forged steel- Double flange hardened to BHN 275 Conforming with IS 807-1976. , BEARING- All bearings are of anti Friction Ball/ Roller Conforming, with IS 6455-1972 , COUPLING- AlI Couplings will be Geared Coupling , SHAFT-All Shafts will be of EN - 9 , RESISTANCE BOXES- AlI resistance boxes will be stainless steel, Wire grid and 15 min. Rated heavy duty, (IS 1822 -1967 ) , LIMIT SWITCH- Rotary Limit Switch for Hoisting & Lever Type for L.T &C.T. Conforming with IS- 3936 - 1983 , PANEL BOXES - All panel boxes will be of steel febricated , CONTROL TRANSFORMER- 750 VA, 44OV / LLOV. , POWER CONTROL CABLE -Sheet Metal housing, DustlVermin Proof having BCH/Siemens Contactors & Overload ReIays BCH time delay Relay , PAINT- Two coats of Red Primer & Two coats of Golden Yellow. , Fullplatform on driving side & two small platform on non driving side.(Monkey ladder &side railing shall be provided by civil) , PART- I : SUPPLY , Supply of Non-FlameproofTandem Operated ( 1 set consist of2 Nos of 5 Ton capacity cranes) 5 Ton capacityDoubleGirder Crab type EOT Crane with VVVF drive complete with long travel and cross travel movements as per technical specifications and as per IS: 807 / IS: 31774137 and other relevant IS standards of the latest revision.All drives should be provided with alternative parallel path with DOL starter for Main Speed only. Span:14.5 mts. ± 0.5 mtrs.to bechecked as per site condition ± Lift: 8.5 mts. Bay length: 73± 0.5 mtr (to bechecked as per site condition ± , Crane operating speeds , Main speed Micro speed , Main hoist:2.5m/min 0.25m/min , Cross travel :10m/min1.0m/min , Long travel: 15m/min 1.5m/min , Micro speedfor all motions : 10% of main speed through VVVF drives. , Provision of inching is to be incorporated in the drives. , Supply of shrouded bus bar system with double shoe copper current collections system complete with support tracks, cable loops, junction boxes and cable from main supply point to crane festoons with all necessary fixtures etc completeas per site condition (For 5 ton capacity crane as per above BOQ EOT 1.1) , Supply of material for Gantry Rails section 60 lb of prime material in length of 10 mts and above complete with mounting arrangement at the building over the crane girder including painting of rails with approximate colour code as approved by the dept as per site condition(For 5 ton capacity crane as per above BOQ EOT 1.1) , Supply of Non-FlameproofTandem Operated ( 1 set consist of2 Nos of 2 Ton capacity cranes) 2 Ton capacityDoubleGirder Crab type EOT Crane with VVVF drive complete with long travel and cross travel movements as per technical specifications and as per IS: 807 / IS: 31774137 and other relevant IS standards of the latest revision.All drives should be provided with alternative parallel path with DOL starter for Main Speed only. Span:17.5 mts. ± 0.5 mtrs.to bechecked as per site condition ± Lift: 5.5 mts. Bay length: 17.5± 0.5 mtr (to bechecked as per site condition ± , Crane operating speeds , Main speed Micro speed , Main hoist:2.5m/min 0.25m/min , Cross travel :10m/min1.0m/min , Long travel: 15m/min 1.5m/min , Micro speedfor all motions : 10% of main speed through VVVF drives. , Provision of inching is to be incorporated in the drives. , Supply of shrouded bus bar system with double shoe copper current collections system complete with support tracks, cable loops, junction boxes and cable from main supply point to crane festoons with all necessary fixtures etc completeas per site condition (For 2 ton capacity crane as per above BOQ EOT 2.1) , Supply of material for Gantry Rails section 50 mm sqr barof prime material in length of 10 mts and above complete with mounting arrangement at the building over the crane girder including painting of rails with approximate colour code as approved by the dept as per site condition(For 2 ton capacity crane as per above BOQ EOT 2.1) , Part-II: - ERECTION, TESTING AND COMMISSIONING , Erection, testing and commissioning ofNon FLP EOTTadem Opereated followingDouble Girder EOT Cranesincluding loaded testing and others mentioned in item S.No.EOT-1.1 to EOT-2.3 of Part-I as per the relevant IS standards and as mentioned in the technical specifications. , Erection, testing and commissioning ofNonFlameproof Tadem Opereated Double Girder EOT Cranes of 5 Ton capacity( 1 set consist of2 Nos of 5 Ton capacity cranes) mentioned in Items .No.EOT-1.1of Part-I with VVVF drive complete with long travel and cross travel movements as per technical specifications and as per IS: 807 / IS: 3177 and other relevant IS standards of the latest revision.including loaded testingAll drives should be provided with alternative parallel path with DOL starter for Main Speed only. Span:14.5 mts. ± 0.5 mtrs. Lift: 8.5 mts. Bay length: 73± 0.5 mtrto bechecked as per site condition ± , Erection testing and commissioning of shrouded type current collection system complete as per the item Sl No.EOT-1.2 of Part I over the crane bay including tapping of supply for electrical panel testing & handing over the crane as per the approved QA plan etc complete as per site condition. , Erection, testing & commissioning of Gantry rail section 60 Lb mentioned in item Sl No.EOT-1.3 of Part -I with mounting arrangementand fixing hardware etc., complete over the bay length to match the span of the crane within the permissible accuracy levels for span in height variation as per the QA Plan etc complete as per site condition. , Erection, testing and commissioning ofNonFlameproof Tadem Opereated Double Girder EOT Crane of( 1 set consist of2 Nos of 2 Ton capacity cranes)mentioned in Items .No.EOT-2.1of Part-I with VVVF drive complete with long travel and cross travel movements as per technical specifications and as per IS: 807 / IS: 3177 and other relevant IS standards of the latest revision.including loaded testingAll drives should be provided with alternative parallel path with DOL starter for Main Speed only. Span:17.5 mts. ± 0.5 mtrs. Lift: 5.5 mts. Bay length:17.5± 0.5 mtrto bechecked as per site condition ± , Erection testing and commissioning of shrouded type current collection system complete as per the item Sl No.EOT-2.2 of Part I over the crane bay including tapping of supply for electrical panel testing & handing over the crane as per the approved QA plan etc complete as per site condition. , Erection, testing & commissioning of Gantry rail section 50 mm sqr barmentioned in item Sl No.EOT-2.3 of Part -I with mounting arrangementand fixing hardware etc., complete over the bay length to match the span of the crane within the permissible accuracy levels for span in height variation as per the QA Plan etc complete as per site condition. , Supply of Test loads of 5 Ton along with Slings and D-shakles (Suitable for 5 Ton, loads of 5 ton -1 no, 1 ton-1 nos, 0.25 ton -1 nos , Supply of Test loads of 2 Ton along with Slings and D-shakles (Suitable for 2 Ton, loads of 2 ton -1 no, 0.5ton -1 nos , SUBHEAD-XXV : BOOM BARRIER: , Supply,Installation,Testing and commissioning of 6 mtr length Boom Barrier electromechanical hydraucally operatedopening and closing times can be adjusted between 3 to 6 seconds and speeds can be adjusted seperately through hydraulic adjusters in a closed circuit system optional emergency close option 2 seconds shall be available with 100% duty cycle with power supply unit,photo sensors,flashing lights on the boom ,push button for entry,exit & Remote control.This shall be along with safety features like Induction and safety loop etc with remote operating facility with remote control unit,along with 4 nos of photo cells with each boom barrier.The system shall be complete in all respects along with all fixing accessories and civil works , SUBHEAD-XXVI :ROADS/HARDSTANDING & DRAINS : , Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres. , Banking excavated earth in layers not exceeding 20 cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller, or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up, in embankments for roads, flood banks, marginal banks, and guide banks etc., lead upto 50 m and lift upto 1.5 m in all kinds of soils. , Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge. , Providing and laying Bituminous concrete using crushed stone aggregates of specified grading, premixed with bituminous binder and filler, transporting the hot mix to work site by tippers, laying with paver finisher equiped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction and density as per specification, complete and as per directions of Engineer-in-Charge. , 40/50 mm compacted thickness with bitumen of grade VG-30 @ 5.5% (percentage by weight of total mix) and lime filler @ 3% (percentage by weight of Aggregate) prepared in Batch Type Hot Mix Plant of 100-120 TPH capacity. , Providing and applying tack coat using bitumen emulsion conforming to IS:8887, using emulsion pressure distributer including preparing the surface & cleaning with mechanical broom.With rapid setting bitumen emulsion. On W.B.M / W.M.M. @ 0.4kg/Sqm. , Providing and laying seal coat of premixed fine aggregate ( passing 2.36 mm and retained on 180 micron sieve) with bitumen using 128 kg of bitumen of grade VG - 10 bitumen per cum of fine aggregate and 0.60 cum of fine aggregate per 100 sqm of road surface, including rolling and finishing with road roller all complete. , Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). , SUBHEAD-XXVII :EXTERNAL WATER SUPPLY SERVICES: , Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. , 25 mm dia nominal bore , 40 mm dia nominal bore , 50 mm dia nominal bore , 100 mm dia nominal bore , Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : , 50 NB , Making connection of G.I distribution branch with G.I mainof folloeing size by providing and fixing tee, inclding cutting and threading the pipe etc. complete: , 25 to 40 mm nominal bore , 50 to 80 mm nominal bore , Providing and fixing gun metal non- return valve of approved quality (screwed end) : , 25mm nominal bore , 40 mm nominal bore , 50 mm nominal bore , Supply,erection, testing and commissiong of C.I Air release valves flanged end type with bolts,nuts and rubber insertions etc., complete andof following sizes: , 25mm nominal bore , 50 mm nominal bore , Supply and Fixing of cast iron pipe line Route Marker for water supply Network system , Borewells , Geological Survey by specialist Agencies and submitting the report for number of poit surved and yield available , Drilling and developing of 61/2 inch dia Bore Wells by DTH method in any type of soil, Conducting yield test as per V Notch method and submission of yield report, including filling of filter media clamps, MS Cover etc., complete. , a) 0-60 mtrs , b) 61-100 mtrs , c) 101-200 mtrs , Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm Dia. , Providing HDPE pipe PE-80 grade (12.5 kg/ sq.cm) of 63 mm OD for bore wells. , Supply, erection, testing and commissioning of 3 Cu.m/hr at 70 m head submersible pump set 3Phase-415V, 50 Hz, 2 HP/ 12 stages, 2900 rpm as approved by Engineer in charge at site.(As per depth of base) , Supply, erection, testing and commissioning of Gun metal Check valve (Non return valve PN-10) conforming to IS 778 with screwed ends type with bolts, nuts and rubber insertions etc., complete and of following sizes: , a)50 NB , Supply, erection, testing and commissioning of Brass / GM / Bronze Air Release valves with threaded ends of following sizes: , a) 25 NB , Supply, erection, testing and commissioning of pressure gauges with range of 0-10 bar along with isolation cock and pipe for bore wells. , Supply, installation, testing and commissioning of weather proof type box (IP-55) made out of 2 mm thick CRCA sheet including painting with epoxy powder coating. The box shall be consisting of star-delta starter suitable for 3 Cu.m/hr and 200 meters head pumpmotor with MPCB, contactor, overload relay, ON/ OFF push button. ON/ OFF/ TRIP indications. Ammeter with resin cost Cts and selector switch, Voltmeter with selector switch. The box shall be suitable for terminating suitable cable. The box shall be mounted on suitable angle frame work of 450 mm height on a PCC pedestal including all materials, complete. , Providing maintenance free Earth station with consisting of 40 mm dia pipe standard length (as per equipment supplier) electrode capsule, filled with earth enhancing compound, sealed at both ends and brazed lead for connection at one end, suitable for direct installation at site, at a depth of 2.5 mtrs. Bentonite compound (as per equipment supplier) upto a depth of 2.0 meters around the electrode capsule. Brick chamber & CI Cover complete. , Supply and laying of following size strips including excavation and refilling of each when laid in ground and with all fixing accessories when laid inside the building including all necessary interconnections with earth station and equipments. , a) 25 x 5 mm hot dip galvanized iron strip , b) 8 SWG GI Wire , Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m in All kinds of soils , Supply, Laying, testing and commissioning of Medium grade G.I. Pipes conforming to IS 1239 Part - I including all necessary fittings etc., complete for sizes , a) 65 NB (Borewell to sump) , b) 50NB (Borewell) , c) 40NB (Borewell to sump) , d) 32NB , e) 25NB , Supply, Erection, testing and commissioning of Cast Iron Butterfly valves (Wafer type) (PN-10) above nd upto 50mm dia with necessary flanges, bolts, nuts etc., and gun metal gate valves from 40mm dia and below , a) 65NB(GM Gate Valve) , b) 50NB(GM Gate Valve) , c) 40NB(GM Gate Valve) , d) 32NB (GM Gate Valve) , e) 25NB (GM Gate Valve) , Constructing of Valve Chamber of size 750 x 750 x 1000mm deep comprising of 230mm thick brick walls in cement mortar 1:5 over a bed of 150mm thick PCC 1:4:8 alround beyond the masonry faces plastered with CM 1:3 mixed with approved water proofing compound as per manufacturers specifications, 13mm thick on internal, external, top surfaces, finished smooth with a floating coat of neat cement, providing and fixing painted light duty double seal CI frame and cover of size 600 x 450mm weighting not less than 52 kgs conforming to IS 1726 with locking arrangements, fixing the frame in RCC 1:2:4 including fabrication, form work, curing etc., complete all as specified and directed. , Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete (a) 50 to 80 mm nominal bore: , Providing and fixing gun metal non- return valve of approved quality (screwed end) :Vertical (a) 50 mm nominal bore . , Supply, laying and commissioning of following size 1.1KV grade PVC insulated flexible Copper conductor in the bore withall installation materials. The cable shall conform to IS 694 , a) 3C x4sqmm (copper ), pvc Flat Water proof cable. , Conducting water yield test without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by V notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. , Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. , 200mm clamp , SUBHEAD-XXVIII : EXTERNALELECRIFICATION , 11KV HT SWITCHGEAR INDOOR , Supply,Installation,Testing and commissioning ofthe following indoor floor mounted 11kv Rated VCB Panel in Metal Enclosure fabricated out of 14 swg sheet steelto be operated on 11KV,Three phase,50HZA.C Power supply .The panel is to be compartmentalised with individual compartments for Bus bars, Cable and CTs and Instrument and relay control Panel. The VCBshall behorizontal draw out single breakas per IS 13118.The short circuit fault level of the system shall be 350MVA- Indoor , 11 KV- H.TSWITCH GEAR PANEL - INDOOR , 11KV VCB panel withone noof1250A vcb -Indoor as Incomer and 3 Nos 800A VCB as out goings. , 11 KV H.T Switch Gear Panel (INDOOR TYPE) With 1 No. OF 1250 Vaccum Circuir breakerasIncomer. , CONSTRUCTION - The Switch Gear Panel shallbe compartmentalised Designed with cubicles fabricatedout of High Quality Sheet Steel. The panels shall be designed having the Following Segregations separately. , a) Busbar compartment , b) Cable and CT compartment , c)) Instrument and Relay Compartment , The clearances between phase to phase and phase to earth shall be provided in accordance with the relevant standards. The bus bars shall be supported by bus support insulators placed at regular intervals. , The panels shall be powder coated with epoxy base paint to give an aesthetically pleasing appearance. The paint shade shall be as per the requirement. , SAFETYFEATURES: , a) Mechanical Interlock and earth switch for out goings , b) Door interlock in service position. , INCOMING VCB PANEL , 11 , KV, 1250A, 26.2 KA,Horizontal Draw out type Vaccum Circuit breaker withmotor/manual spring charge mechanism and also with mechanical indications for breaker on /off/trip indications and also with Local Remote selector switch and with breaker TNC Switch. , CURRENT TRANSFORMER: (3 No’s) Cast Resin , Ratio 200-100- 5/5 A, Core 1: 15 VA, CI – 0.2 for Metering and 5P10 for protection. , METERING: ( 1set) , 96 Sq.mm Digital Ammeter with selector switch Digital type 0-200A. , POTENTIAL TRANSFORMER: (3 No’s) Cast Resin , Ratio 11000 V/ rt 3 / 110 v / rt 3 , 100 VA, CI – 0.2 for Metering and 3 P for Protection and also with 2 numbers of Under Volage relays. , OUTGOING VCB PANEL , 11 , KV, 800A, 26.2 KA,Horizontal Draw out type Vaccum Circuit breaker withmotor/manual spring charge mechanism and also with mechanical indications for breaker on /off/trip indications and also with Local Remote selector switch and with breaker TNC Switch.-Outgoing-4Nos , CURRENT TRANSFORMER: (3 No’s) Cast Resin , Ratio 75 /5 A, Core 1: 15 VA, CI – 0.2 for Metering and 5P10 for protection. , METERING: ( 1set) , 96 Sq.mm Digital Ammeter with selector switch Digital type 0-100A. , Digital Multi function Meter for KW,KWH,KVA, KVAR , COS PHI Parameters reading. , INDICATION LAMPS: , 1) TCH, Battery failure , Spring charge, discharge, ON, OFF and Trip Indication Lamps, Phase indication Lampsfor RYB.-(1 set) , CONTROL SWITCHES/PUSH BUTTON , Bus Bar with 1250 Amps Copper- (1 set) , COMMON FOR SWITCHGEAR: , Heater ON and OFF Switch with Space heater, single Phase switch socket and cubicle lamp for panel illumination, MCBs for AC/DC Control - (1 set) , MS sheet enclosure suitable for Indoor installation withoutgoing cable entry.- (1 set) , RelaysIncomer ; Undervoltage relays 2 nos,IDMT relay ,TCH and Master trip relay and also with 12 window annunciator , Power Pack - 1 No with necessary Interconnections. , Supply andcommissioning of 11KV earthed HT cable of size3 c x300 sqmm XLPE insulated armoured alluminium conductor cable as per IS 7098- Part 2 - 1983 , Supply andcommissioning of 11KV earthed HT cable of size3 c x185 sqmm XLPE insulated armoured alluminium conductor cable as per IS 7098- Part 2 - 1983 , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. , Above 120 sq. mm and upto 400 sq. mm , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. , Above 120 sq. mm and upto 400 sq. mm , Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size on cable tray as required. , Above 120 sq. mm and upto 400 sq. mm , Supply, Installation, Testing and commissioning of 11 KVearthed heat shrinkable end termination kit of 11 KV earthed XLPE insulated armoured alluminium conductor HT Cable of size 3 c x 300sqmm ( Indoor Termination Kit). , Supply, Installation, Testing and commissioning of 11 KVearthed heat shrinkable end termination kit of 11 KV earthed XLPE insulated armoured alluminium conductor HT Cable of size 3 c x 185sqmm ( Indoor Termination Kit). , Supply and Installation ,Commissioning of HT Straight through Joint Kit for 3 C x 300 Sqmm EarthedXLPE insulatedarmoured alluminium conductor cable. , Supply, Installation, Testing and commissioning of 1000KVA, 11kv / 433 v, 3 PHASE, 50 Hz, Dyn 11 ,outdoorANAN Resin cast dry typeTransformerwithon load tap changer, RTCC panel, AVR andHT Side marshalling box for termination of 11 kv grade , 3 c x 300 sqmm XLPEinsulated alluminium conductor screeened cable and LT side provision for connecting sandwich type of Alluminium bus trunking system of 1600 A capacityas per IS 11117 etc , LT SANDWICH TYPE BUS DUCT , Supply, Installation, Testing and commissioning of 415 V, 50 Hz, A.C, 1600 A, Three phase and neutral Sandwhich type Alluminium bus bars Bus trunking system with necessary fixing Clamps and Jointing accessories including all required horizontal and vertical bends, tees for outdoorApplicationIp -65( Transformer feeder Incomer ) .As p-er IS ; 8623 Part 1 & 2. , M.V.PANELS , Supply,Installation Testing Commissioning of following TTA PANEL.Supply, erection, testing and commissioning of 415V, 3 phase 4 wire 50 c/s Main LT Panel at Substation fully compartmentalized cubical type, as per the standards IEC61439-1&2 as tested assembly (TTA) ,tested for impulse voltage 8 KV,IP 42 fabricated CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having required capacity extensible type FP bus bars of high conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 35KA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, Form of separation shall be form 4b with metallic separation only entire panel shall have a common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of bus bars, interconnection, interlocking between feeders etc.,with indication lamps, push buttons necessary accessories, complete with following incoming and outgoing switchgears with protection and metering etc. as per specification and schematic diagram including provision to be made for interfacing with BMS etc. complete as required, with incoming & outgoing cable entry from bottom/top and bus-duct entry from top, wiring with 2.5sq. mm. FRLS insulated copper conductor , cable alleys, PLC cable gland i/c providing following switch gears All ACBs should have Ics=Icu=Icw for 1 sec All MCCBs shall be rating for 25kA (Ics=Icu). All MCCBs above 63A should be provided with Copper Spreader Terminals Marshalling Bay To Be Provided for BMS Operation Approval shall be taken for each panel before fabrication. PLC based control with 100% hot redundant PLC arrangement with touch-screen LCD / LED display board (min. 8 Diag size)along with all accessories for complete automatic, manual andHMI controls & indication. Energy Management Software wth necessary cabling shall be in scope, nos. of breaker / Meters to be connect with energy management software shall be inform by Engineer In Charge. , MAIN MVPANEL - 1- Indoor , Incomer 1,3,4 : 3 Nos of 1600 A, 4P. EDO ACB, 50KA,shallbe supplied with S/C,E/F,O/C AND INSTANTANEOUS TRIP RELAY UNIS WITH TIME DELAY SETTINGS. , 2A, control MCB - 9 Nos. , RYB indicating lamps - 3 sets , Voltmeter (0-500V) with selector switch - 3 sets , Ammeter (0-1600A) with selector switch - 3 sets , 1600/5A, CL-1, 15VA CTs with resin cast- 3 nos. , A Single CT with ratio of1600 / 5 A , 15 VA, 5 P 10 ,CT for feeding APFC relay of APFC panel. ( For 3 Nos of Incomers ) , Bus Coupler : 3 Nos of 1600 A, 4P. EDO ACB, 50KA,shallbe supplied with S/C,E/F,O/C AND INSTANTANEOUS TRIP RELAY UNIS WITH TIME DELAY SETTINGS. , Incomer 2 : 1 No of 1250 A, 4P. EDO ACB, 50KA,shallbe supplied with S/C,E/F,O/C AND INSTANTANEOUS TRIP RELAY UNIS WITH TIME DELAY SETTINGS. , 2A, control MCB - 3 Nos. , RYB indicating lamps - 1 sets , Voltmeter (0-500V) with selector switch - 1 sets , Ammeter (0-1250A) with selector switch - 1 sets , 1250/5A, CL-1, 15VA CTs with resin cast- 1 nos. , A Single CT with ratio of1250 / 5 A , 15 VA, 5 P 10 ,CT for feeding APFC relay of APFC panel. , Outgoing , 1250A, 3P, 50KA, EDO ACB - = 2 Nos , 800A, 3P, 50KA, EDO ACB - = 3 Nos , 630A, 3P, 50KA, EDO ACB - = 3 Nos , 250A, 3P, 35KA, MCCB, -=1 No , 200A, 3P, 35KA, MCCB, -=1 No , 160A, 3P, 25KA, MCCB, -=2 Nos , 63A, 3P, 16KA, MCCB, -=3 Nos , Surge Protection Device - 1 No , 63 A, 3P, 16KA, MCCB, -= 1 No and also with 20 A TPNMCB as outgoings 3 Nos with timer circuit for controlling of street lights and the timer should be with required24 hors clock settings. , Bus Bars : 1600A, 3Ph, 4 wireTPN , 50Hz, aluminium bus bars , Metering Instruments ; Load Manager in the Incomer and ACB/ MCCB on , off , Trip Indication Lamps and with Breaker Status indication Lamps and also with Phase indication Lamps. , Earth Bus; To be provided at the bottom of the Panel of Gi Strip , MAIN BUILDING PANEL- INDOOR , Incomer: 1 No of 1250 A, 4P. EDO ACB, 50KA,shallbe supplied with S/C,E/F,O/C AND INSTANTANEOUS TRIP RELAY UNIS WITH TIME DELAY SETTINGS. , 2A, control MCB - 3 Nos. , RYB indicating lamps - 1 sets , Voltmeter (0-500V) with selector switch - 1 sets , Ammeter (0-1250A) with selector switch - 1 sets , 1250/5A, CL-1, 15VA CTs with resin cast- 1 nos. , A Single CT with ratio of1250 / 5 A , 15 VA, 5 P 10 ,CT for feeding APFC relay of APFC panel. , Outgoing , 630A, 3P, 50KA, EDO ACB - = 2 No , 630A, 3P, 50KA, MCCB - = 2 Nos , 250A, 3P, 35KA, MCCB, -=3 Nos , 200A, 3P, 35KA, MCCB, -=2 Nos , 63A, 3P, 16KA, MCCB, -=3 No , Surge Protection Device - 1 No , Bus Bars : 1250A, 3Ph, 4 wireTPN , 50Hz, aluminium bus bars , Metering Instruments ; Load Manager in the Incomer and ACB/ MCCB on , off , Trip Indication Lamps and with Breaker Status indication Lamps and also with Phase indication Lamps. , Earth Bus; To be provided at the bottom of the Panel of Gi Strip , APFC PANEL INDOOR TTA PANEL - 300KVAR , Supply,Installation,Testing andCommissioning of APFC PANEL with Automatic power factor control relay and with 2 nos of 50 kvar capacitor banks and 25 kvar capacitor banks 8 nos with the following incoming and out goings.. The Panel is to be installed in Indoor. The panel is to be supplied with necessary power and control wiring required for the automatic operation of Power factor control. , INCOMER , 630 A, 4 P , 50KA MCCB with O/c, S/c,E/f Protection Microprocessore Relay Unit , 2A, control fuse - 3 Nos. , RYB indicating lamps - 1 set , Voltmeter (0-500V) with selector switch - 1 set , Ammeter (0-630A) with selector switch - 1 set , 630/5A, CL-1, 15VA CTs with resin cast- 3 nos. , Outgoing , 125 A, 3P, SDF , - 2No , 63 A, 3P, SDF , - 8 No , Bus Bars : 630A, 3Ph, TPN, 50Hz, aluminium bus bars , Metering Instruments ; Multi Function Meter in the Incomer and SDFon , off , TRIP Indication Lamps and with Breaker Status indication Lamps and also with Phase indication Lamps , Earth Bus; To be provided at the bottom of the Panel of copper , The panel is to be supplied with Required capacity Capacitor Banks as per BOQ quantity and also with required capacity over load relays,contactors ,Switch disconnecting fuses and also with APFC relay control wiring for manual and Auto operation. , EARTHING , Providing and fixing of maintenance free earthing which consists of 40 mm Dia, 3 mtr length (as per Equipment Supplier) electrode capsule,filled with earth enhancing compound,sealed at both ends and brazed lead for connection at one end suitable for direct installation at site at a depth of 2.5 mtr.Bentonite compound upto a depth of 2.0 mtr around the electrode capsule and also wih brick chamber and cast Iron cover etc complete including excavation in all types of soil. , Providing and fixing of maintenance free earthing which consists of 65 mm Dia, 3 mtr length (as per Equipment Supplier) electrode capsule,filled with earth enhancing compound,sealed at both ends and brazed lead for connection at one end suitable for direct installation at site at a depth of 2.5 mtr.Bentonite compound upto a depth of 2.0 mtr around the electrode capsule and also wih brick chamber and cast Iron cover etc complete including excavation in all types of soil. , Supply and fixing of following earth strips/ conductors.The scope incudes supply and fixing of copper lugs wherever found necessary, brass bolts, nuts and washers for fixing arrangement etc., (from earth station to main panel). , 50x5 MM G.I.Flat , 25 x3 MM GI Flat , 50 x 6MM Copper Flat , 6SWG G.I.Wire , Cable Trays , Supply and fixing of following size GIPerforated type cable tray made out of 2mm thick sheet including MS supports for fixing the tray, anchor fasteners etc complete as required.Including with GI covers. , 600mm wide , 300mm wide , SAFETY ITEMS , Supply, Installation, Testing and commissioning of the Follwing Safety itemsas per standrads and specification. , Fire Extinguishers- 5 KG CAPACITY CO 2 Confirming to IS 2878 fitted with discharge bend pipe and horn , Rubber Mats 11 KV , 2 Mtr x 1 Mtr , Rubber Mats 415 V , 2 Mtr x 1 Mtr , Shock treatment Chart with frame and glass , First Aid Box , Sand Bucket with stand with 3 Nos of buckets and also with canaopy. , 415 V Danger Boards , 11 kv Danger Boards , Single Line Diagram with frame and glass. , Supply, testingand commissioning of following size 1.1KV grade XLPE insulated armoured aluminium conductor cable. The cable shall conform to IS 7098/ Part-II. , 3.5C X 400Sq.mm , 3.5C X 300Sq.mm , 3.5C X 240Sq.mm , 3.5C X 185Sq.mm , 3.5C X 150Sq.mm , 3.5C X 95Sq.mm , 3.5C X 70Sq.mm , 3.5C X 50Sq.mm , 3.5C X 25Sq.mm , 4C X 16Sq.mm , Copper armoured control cables , i) 4C X 2.5Sq.mm , ii) 7C X 2.5Sq.mm , iii) 19C X 2.5 Sq.mm , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. , Upto 35 sq. mm , Above 35 sq. mm and upto 95 sq. mm , Above 95 sq. mm and upto 185 sq. mm , Above 185 sq. mm and upto 400 sq. mm , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. , Upto 35 sq. mm , Above 35 sq. mm and upto 95 sq. mm , Above 95 sq. mm and upto 185 sq. mm , Above 185 sq. mm and upto 400 sq. mm , Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. , Upto 35 sq. mm , Above 35 sq. mm and upto 95 sq. mm , Above 95 sq. mm and upto 185 sq. mm , Above 185 sq. mm and upto 400 sq. mm , Providing Indoor ordinary end terminations for thefoollwing 1.1 KV grade XLPE insulated armoured alluminium conductor cables with compression type steel gland, Bi-metallic lugs using crimping tool, Insulation tape, Identification tags etc., including end termination and Earthing of Gland with 8SWG GI Wire. , 3.5C X 400Sq.mm , 3.5C X 300Sq.mm , 3.5C X 240Sq.mm , 3.5C X 185Sq.mm , 3.5C X 150Sq.mm , 3.5C X 95Sq.mm , 3.5C X 70Sq.mm , 3.5C X 50Sq.mm , 3.5C X 25Sq.mm , 4C X 16Sq.mm , End terminations of Copper armoured control cables including supply and fixing of crimping type copper lugs. , i) 4C X 2.5Sq.mm , ii) 7C X 2.5Sq.mm , iii) 19C X 2.5 Sq.mm , SUBHEAD-XXIX : AREA LIGHTING : , Supply and erection of steel stepped and swaged tubular poles of 9 mtr long(410 SP25) (1.5 mtr below ground) with base plate earthing studs 1.5 mtr out reach single /Double arm , FRP terminal Box 2 Nos of 40 mm Dia Class B G.I Pipe ,0.5 mtr Longfor incoming and outgoing cables including excavation in all types of soil ,PCC 1:2:4 ,PCC Pedestal with painting with black bitumen paint inside the coping for embedded portion and two coats of Zinc chromite primer and two coats of Alluminium paint externally for length above the ground.The pole shall be with FRP junction box consisting of 10A MCB.The wiring from Junction box to Light fixture shall be carried out with 3 Core 2.5 Sqmm Copper conductor flexible cable. , The Street Light Pole shall be fixed with 70W LED street Light fixture including supply of controlgear / driver and lamp(Make : Cat No.LR02-102-XXX-57-G2,WIPRO MAKE / CAT NO - Greenline V2 (BRP410) Philips/equivalent make.) , Supply and erection of 65 mm Dia, Class B GI Pipe of 3 mtr. long with base plate, earthing studs, 3 phase and neutral loop-in and loop-out box as per specifications, 2nos 50mm dia,1.5mtr. long GI bent pipes for incoming and outgoing cables, including excavation , 1 :2 : 4PCC Pedestal etccomplete. The pole shall be with Junction box consisting of MCB.The Junction box shall be of weather proof. The wiring from Junction box to Light fixture shall be carried out with 3core 2.5sq.mm flexible copper conductor cable. The Pole shall be fixed withweather proof 72W LED ( Philips Cat No :BRP046 LED 30 CW MR S1 PSU GR/equivalent) Light fixtureincluding supply of driver and fixing clamps etc complete. , Supply, testingand commissioning of following size 1.1KV grade XLPE insulated armoured aluminium conductor underground cable. The cable shall conform to IS 7098/ Part-II. , 4Core10sq.mm , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required , Upto 35 Sqmm , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. , Upto 35 Sqmm , ProvidingEnd terminations for the following size of 1.1 KV grade XLPE insulated armoured alluminium conductorcablewith compression type steel gland, alluminumlugs using crimping tool, Insulation tape, Identification tags etc.,complete , 4Core 10 sq.mm , Providing Spiral coil earthing with 8 SWG GI wire including spreading of salt and charcoal as per IS 3043/87 with latest amendments. , Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, weather proof MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powderpainted including earthing etc. as required. (But without MCB/RCCB/Isolator) , 4 way (8 + 12), Double door , Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuitbreaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. , 40A , Supplying and fixingof 6A to 32A rating 240/415V,10kA , C Curveminiature circuit breaker suitable for inductive load of following polesin the existing MCB DB complete with connections ,testing and commissioning etc complete. , Single Pole , Supply and Commissioning of thefollowing type Fluorescent/ Compact fluorescentlight fixtures on wall/ Ceiling including all fixing accesssories such as leads, etc complete as required. The Fluorescent/CFL fixtures shall be complete with Low loss copper ballast PF improvement capacitor, Bipin Rotor type lamp holder,starter, starter base, all prewired upto the terminal block. All fixtures shall besupplied with lamps. The Catalogue Numbers refers to Philips Make. , 40 W Bulk Head Light Fixture Outdoor , (PhilipsCat No WT1 40W LED 7S NW PSU S1 PC /Equivalent as per approved makes)) , 150WLED Flood Light Fixture outdoor with alluminium die cast housing and also includind driver with fixing clamps etc complete , (PhilipsCat No BVP283 LED240 CW FG SY5NB 200W V1 /Equivalent as per approved makes)) , Installtionof Fluorescent/ Compact fluorescentlight fixtures on wall/ Ceiling including all fixing accesssories such as leads, etc complete as required. , SUBHEAD-XXX :SEWAGE DISPOSAL : , Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m in All kinds of soils. , Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. , PVC SWR PIPES , Providing, laying and jointing PVC/ SWR Pipes conform to IS:13592-1992 of Type-B on sand cushion at bottom and around the pipw and testing of joints etc. complete : , 100 mm dia PVC/SWR Single Socket , 150 mm dia PVC/SWR Single Socket , Providing and fixing square-mouth PVC gully trap conform to IS:13592-1992 complete with brick masonry chamber around as per standard design : , 100x100 mm PVC Gully trap with Sewer bricks conforming to IS : 13592-1992. , Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : , Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), With Sewer bricks conforming to IS : 4885. , Extra for depth for manholes : , Size 90x80 cm, With Sewer bricks conforming to IS : 4885 , Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design, With 20x20 mm square bar. , Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design, With common burnt clay F.P.S. (non modular) bricks of class designation 3.5. , Supply and positioning of ready made polyethylene septic tank of size 2.3M long 1.3M dia 16mm shell thickness with 2/3 chambers and 2Nos manholes of size 550mm dia and 100mm/160mm dia inlet outlet pipe and airvent pipe 50mm dia of make United Septic tank Design Reg.No 173352 Type-4 , SUBHEAD-XXXI : ARBORICULTURE : , TREE PLANTATION , Digging pits in all type of soils and refilling the same with the good earth (excavated / imported) & manure (organic manure/cow dung/sludge) in the ratio of 3:1 (03 part of stacked volume of manure). Cost of manure / sludge and good earth if needed to be paid separately, after reduction of 20% of stacked volume of good earth &8% stacked volume of manure. Each pit to be mixed with antitermite chemical / granules, Thimet 10G @100-200 am/pit , (I) AVENUE / FLOWERING TREES / Palms , a) 1mts x 1mts x 1mts (L X W x D ) , b) Each pit to be added with 100gms of Thimet 10 g granule, to control termite attack. (Repeat the treatment after 06 months, if termite persists). Flooding the pit basin with water, dressing including removal of rubbish & surplus earth, if any, with all lead & lifts , c) Supply and plantation of approved varieties of healthy, disease free, stout stem & well developed root system tree sapling of, 5-6 height, with a clear minimum height of 4-5 from basin / ground level, after plantation. Staking the tree sapling upto 3/4 height with appropriate strength of bamboo stick. Lower 1 feet of stake portion should be treated with antitermite chemical , i) Phonix Palm , ii) Red Palm , iii) Golden Palm , iv) Fox Tail Palm , v) Areca Palm , d) Maintenance of tree sapling, after plantation for 30 days or more as minimum guarantee period, for well establishment of tree sapling. Stacking to be continued till tree sapling attains the stem strength. Replacement of saplings casualties immediately , LAWM PLANTATION , a) Preparation of ground by trenching in all type of soils upto a depth of 30cm including removal & stacking of serviceable material than disposing the surplus soil with all lead & lifts, by spreading and leveling neatly. Making up the trenched area well leveled by filling with additionally supplied earth (if needed). , b) Now rough dressing of trenched ground including breaking clods & flooding with water. , c) After 10-15 days removal of weeds / unwanted grass (motha etc) with roots & disposal of uprooted material, stone rubbish etc., with all lead & lifts. , d) Then fine dressing of ground. Spreading and mixing with the good earth (excavated / imported) & manure (organic manure / cow dung / sludge) in the ratio of 8:1 (08 part of stacked volume of good earth if needed to be paid separately, after reduction of 20% of stacked volume of good earth & 8% stacked volume of manure. The area to be mixed with antitermite chemical / granules, Thimet 10G @ 100-200gm / sqmts. If termite persists repeat the treatment after 06 months by surface spreading the chemical. , e) Supply of grass and planting by dibbling the area including watering & maintenance of lawn for 30 days or more till grass forms a thick lawn cushion free from weeds , i) With Bermunda grass (15cm x 15cm apart) , ii) Carpet of grass turfing , iii) Supply & turfing of artificial lawn , iv) After ward maintenance of lawn area, green & weed free for 01 year with standard specification , SHRUB PLANTATION (SOLO) , Digging pits in all type of soils and refilling the same the good earth (excavated / imported) & manure (organic manure / cow dung / sludge) in the ratio of 5:1 (05 part of stacked volume of manure). Cost of manure / sludge and good earth if needed to be paid separately, after reduction of 20% of stacked volume of good earth & 8% stacked volume of manure. Each pit to be mixed with antitermite chemical / granules thimet 10G @50-100gms / pit , i) Pit size 0.60mts x 0.60mts (Dia x Depth) , ii) Pit size 0.45 dia x 0.60mts Depth , b) Supply & plantation of shrub and / or rose sapling to pit, appropriate stacking & initial maintenance for 30 days. Replacement of sapling casualties immediately. , c) Afterward 01 year maintenance as per standard specification , SHRUBBERY PLANTATION - (SHRUBS IN GROUPS) , Digging beds in all type of soils and refilling the same with the good earth (excavated / imported) mixed with antitermite chemical / granules @100gm/sqmts) & manure (organic manure / cow dung / sludge) in the ratio of 5:1 by volume (05 part of staked volume of good earth & 1 part of stacked volume of manure). Cost of manure / sludge and good earth if needed to be paid separately, after reduction of 20% of stacked volume of good earth &8% stacked volume of manure , i) L X W X 0.60 mts depth , b) For roses, rose mixture @500gms / sq mts to be used additionally, before plantation , c) Termite treatment - Thimet 10G granules @100 gms / Sqmts , d) Supply & plantation of shrub sapling to pit, appropriate stacking & initial maintenance , e) Afterward 01 year maintenance as per standard specification , HEDGE PLANTATION , a) Digging trenches of approved / desired size of L X W (45-50cms) X D (30-60cm) in all type of soil. Refilling the trenches with good earth (excavated / imported) mixed with manure (cowdung / sludge / dump) in the ration of 5:1 (05 part of good earth and 01 part of manure by stacked volume). Cost of manure / sludge and good earth if needed to be paid separately, after reduction of 20% of stacked volume of good earth &8% stacked volume of manure. Fore Termite treatment add Thimet 10G granules @ 100gms / running mts. Flooding the trench with water and than rough & fine dressing of trenched area including removal of undesirable weeds & vegetation. , b) Supply & plantation of approved varieties of hedge plant saplings. It should be well grown, fully established & disease free. Sapling height & density as follows , i) Hedge with sapling height -0.45 mts to 0.60mts (After Plantation) , ii) Density - @07 Nos plants / running meters (staggered condition) , c) Maintenance the hedge by regular watering, trimming & pruning etc for 30 days initially. Replacement of sapling casualties immediately , d) Afterward maintenance of hedge length for 01 (one) year as per standard maintenance specification , GROUND COVER , Digging of ground cover marked area upto a depth of 30 cms in all type of soils. Refilling the same with (excavated / supplied) good earth mixed with manure (organic / cow dung / sludge) in the ration of 8:1 (08 part of good earth *01 part of manure by stacked volume). Cost of manure / sludge and good earth if needed to be paid separately, after reduction of 20% of stacked volume of good earth & 8% stacked volume of manure. For Termite treatment add Thimet 10G granules @100 gms/Sq mts. Flooding with water the entire area. Rough & fine dressing of the ground cover bed area and removal of weeds & unwanted vegetation & its disposal , b) Supply and plantation of approved / desired ground cover plant varieties, well established, fully grown, disease free and good foliage. Plantation density should be @36 ground cover plants / square metre, or less as desired or decided by site incharge. Maintenance of all the ground cover area for 30 days till the plants establish well. , c) Regular maintenance afterward for 01 year as per standard specification , FLOWER BED PREPARATION , Digging of FLOWER BED marked area upto a depth of 30 cms (Canna Beds - 60cms depth) in all type of soils. Refilling the same with (excavated / supplied) good earth mixed with manure (organic / cowdung/ sludge) in the ration of 5:1 (05 part of good earth & 01 part of manure) . Cost of manure / sludge and good earth if needed to be paid separately, after reduction of 20% by stacked volume of stacked volume of good earth & 8% stacked volume of manure. For Termite treatment add Thimet 10G granules @100gms / sq mts. Flooding the entire with water. Rough & fine dressing the flower bed area and removal of weeds & unwanted vegetation & its disposal with all lead and lifts , a) SEASONAL FLOWERING BED SIZEFORMAL STYLE - Lx1.0mts width, INFORMAL STYLE - Any style as desired , b) Supply & plantation of seasonal flowers sapling @36 seedlings / sq mts (minimum three times in a year) , i) BUL BOUS / CUTTINGS - FLOWERING - Dahalia Plants @16 plants / Sqm) Winter , c) Maintenance of flower beds regularly upto 1 year as per standard specifications. Replacement of casualty immediately , MOUND , Preparation of mounds of various size and shape by available excavated / supplied earth in a layers not exceeding 20cm in depth, breaking clods, watering of each layer, dressing etc with all lead & lifts complete as per direction of Officer in charge. Cost of manure / sludge and good earth if needed to be paid separately, after reduction of 20% of stacked volume of good earth and 8% stacked volume of manure , BRICK EDGING , Edging with bricks (Class I) laid in PCC (1:2:4) length wise, including required excavation, refilling, consolidating withhand packing and spreading surplus earth neatly within all lead and lifts , Brick Paving : Supply and Paving of wire cut bricks on sand bed , Terracotta Pot : Terracotta Pots of height 4 & width 1m made with 8mm rod chicken mesh with cement mortar complete , PVC Pipe Line : Supply & laying of 63mm dia PVC pipeline of ISI including excavation of outlet back filling of trenches of 0.60m depth fixing with all accessories and providing outlet wherever required backfilling of trenches etc complete , Supply & erection of 2 Hp pump with all accessories including panelboard etc , Supply, erection, testing and commissioning of 1.5sqmm 3 core copper cable , GOOD EARTH / AGRICULTURE SOIL , a) Supply and stacking of good earth / agriculture soil from approved source / field ; of approved quality / pH & suitable for plantation work with all leads, lifts, carriage and royalty / taxes etc. Cost of good earthto be paid separately, after reduction of 20% of stacked volume of good earth , b) Cattle manure : Supply of cattle manure , Note:- Where Ever Written for Sand Should be Read as Manufacture Sand
Contract Date : 25 Feb, 2025   |   Contract Value : 47.47 Crore
Disclaimer

We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.

Tender Detail
Website https://prasarbharati.eproc.in/ProductPB/publicDash
Quantity
MSME Exemption No
Tender Type Open Tender
Startup Exemption Click Here
Competitive Bidding NCB
Similar Tenders
TENDER INSIGHTS

858

Electric Tenders
Live
CLICK TO KNOW MAXIMUM WIN

Tell us about your Product / Services,

We will Find Tenders for you

🇮🇳 +91
TenderDetail
Loading tenders