Tender For Electrical Work – Supply, Installation, Testing And Commissioning
Tender Overview
Project Description
Tender For Electrical Work – Supply, Installation, Testing And Commissioning 1.0 Supply,Erection,Testing&Commissioningofthefollowingfrontoperated(Doubledoor),withCanopy,frontaccesstotallyenclosedsheetsteelclad,freestanding,dust&verminproofswitchboardwithIP42protectionwithhanged,gasketed&cabledoorsincludinginterconnection,coppercrimpinglugs,boardingtoearthandpowdercoatedpaintedsuitableforuseat415volt,3phase,4wire,50Hzsystemandwith35KAreputingcapacityat415 volt complete as per Drawing and specification :- EachIncomertohaveonemultifuncationmeter(A,V,Hz,PF,kW,KWH)alongwithsetofindicatinglightR,Y,B,controlledby2A MCB. EachACBtohaveseparatespringchangedswitchfortrippingofbreaker. Allincomingsupplytobeinterlockedwithbuscouplerandtheincoming supply from CSS1 & CSS2. (a) INCOMER :- 2 Nos. 1600A 4 Pole micropossessor based EDO ACB ( CSS1 & CSS2) complete as per SLD Supply. (b) BUSCOPLER :- 1 Nos. 1600A 4 Pole micropossessor based EDO ACB. Busbar 2000A TP AL Busbar with heat shrinkable coloured sleeves complete and with standing fault level of 36kA capacity. ( c) INCOMER SECTOR- 1 CSS 1 3 Nos. 630A 3P TM 36kA MCCB complete with handle & spreader link & solid neutral link. 1 Nos. 400A 3P TM 36kA MCCB complete with handle & spreader link & solid neutral link. 2 Nos. 250A 3P TM 36kA MCCB complete with handle & spreader link & solid neutral link. 3 Nos. 63A 4P 10kA MCB CSS 2 3 Nos. 800A 3P 36kA TM MCCB complete with handle & spreader link & solid neutral link . 1 Nos. 630A 3P 36kA TM MCCB complete with handle & spreader link & solid neutral link. 1 Nos. 250A 3P 36kA TMM MCCB complete with handle & spreader link & solid neutral link. 3 Nos. 63A 4P 10kA MCB Nos. 1.0 - 2.0. Feeder Panel (LT Room ) Supply, Erection , Testing & Commissioning of the following front operated, front access totally enclosed sheet steel clad, free standing, dust & vermin proof switchboard with IP42 protection with hanged, gasketed & cable doors including inter connection, copper crimping lugs, boarding to earth and powder coated painted suitable for use at 415 volt, 3 phase, 4 wire, 50Hz system and with 35KA reputing capacity at 415 volt complete as per Drawing and specification :- Incomer 630Amp, 4P , 36kA (ICS=ICU=100%) complete with ROM handle & spreader link MCCB. 1 Set of multifunction meter A, V, kW, kWH, Hz, Meter with set of indicationg light R, V, B controlled by 2A MCB. 800A, 4P, AL Busbar complete so as is have with standing fault level of 25kA capacity. Outgoing :- 1 Nos., 400A, 4P 36kA TM, MCCB Complete with EROM & Spreader link & solid neutral link. 4 Nos. , 250A, 4P 25kA TM MCCB complete with EROM & Spreader link & solid neutral link. 2 Nos. 125A, 4P 25kA TM MCCB complete with EROM & Spreader link & solid neutral link. Nos. 1.0 - 3.0 Supply of 1.1 KV grade multicore AL conductor XLPE insulated & PVC sheqted armoured power cable as required ( Contractor to be paid on actual usage/Installation of cable ) (a) 3.5 Core X 300 Sqmm Mtr. 500 - (b) 3.5 Core X 240 Sqmm Mtr. 500 - 4.0 Dismantling&removing/pullingofexistingPVC1.1kVgradecablesfromtheCSS1/CSS2&ACplantroomandold/newwingblock as per following sizes. (a) Size between 185 Sqmm to 300 Sqmm. Mtr. 400 - (b) Size between 70 Sqmm to 150 Sqmm. Mtr. 400 - 5.0 RelayingofExistingCablesofPVC1.1kVgradeintheexistinghume pipe / Existing trench and as per following (a) Size between 185 Sqmm to 300 Sqmm Mtr. 400 - (b) Size between 70 Sqmm to 150 Sqmm. Mtr. 400 - 6.0 LayingofPVCinsulatedandPVCsheathedpowercableof1.1kVgradeoffollowingSizesingroundinexistinghumepipeorintrench / in ground. (a) 3.5 Core X 300 Sqmm Mtr. 500 - (b) 3.5 Core X 240 Sqmm Mtr. 500 - 7.0 Dismantling of existing cable end termination / then re-termination ofthefollowingsizeXLPEcable,1.1kVgradeincludingcostorcrimpingtinnedcopper/ALheavydutylugs,doublecompressiongland,insulationtapeandallrequiredmaterialforcompletionofjoints. (a) Size between 185 to 300 Sqmm Cable Nos. 20 - (b) (a) Size between 185 to 300 Sqmm Cable Nos. 16 - 8.0 TerminationofnewcableofthefollowingsizeXLPEcable1.1voltgradeincludingcostOfcrimpingtinnedcopper/ALheavydutylugsdoublecompressionglades,insulationtapeandallrequiredmaterial for termation of cable. (a) 3.5 X 240 Sqmm Cable Nos. 30 - (b) 3.5 X 300 Sqmm Cable Nos. 20 - 9.0 Supply&layingoffollowingearthingclampedtowall/floorwithsuitableclamps,sidles,andfixingbothinground.Completeasrequired it canopy with IS 3043:1987. (a) 50 X 6 mm GI Strip Mtr. 50 - (b) 25 X 6 mm GI Strip Mtr. 50 - 10.0 Supply insulation Testing & Commissioning of 4 Pole, 415 Volts off load changer on switch duly mounted on angle frame & in enclosure as per following (a) Off load 250A changeover switch Nos. 3 - 11.0 Supply, Installation, Testing & Commissioning of straght through joint for the following cables. (a) 3.5 X 300 Sqmm AL 1.1 kW armoured cable Nos. 2 - (b) 3.5 X 240 Sqmm AL 1.1 kW armooured cables. Nos. 2 - 12 Supply, Installation, Testing & Commissioning of straght through joint for the following cables. - (a) 3.5 X 300 Sqmm AL 1.1 kW armod cable Nos. 2 - (b) 3.5 X 185 Sqmm AL 1.1 kW armod cables.
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Offline submission at the designated office.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender