A) Strengthening And Upgradation Power Supply Arrangement In Se & Ne Sections By Providing 110 / 22 Kv Substation, 22 Kv Cabling And Distribution Transformers At Each Stations For General Services Loads. (B) Strengthening And Up Gradation Power Supply

Published: 15 Feb 2023
Opening: Ref Document
Closing: 09 Mar 2023
Amount: 2.35 Crore
EMD: 2.67 Lakhs
Tender Fee: Ref. Documents


Works Active Harmonic Filter Actuator Aerial Cable Aerodrome Beacon Air Circuit Breaker
0
Days Left
Tender Summary / Eligibility Criteria
A ) Strengthening And Upgradation Power Supply Arrangement In Se & Ne Sections By Providing 110 / 22 Kv Substation, 22 Kv Cabling And Distribution Transformers At Each Stations For General Services Loads. ( B ) Strengthening And Up Gradation Power Supply Arrangement In Se ( Neral ) Sections By Providing 22 Kv / 415 V 2 Nos. 250 Kva Compact Substation Comprising Of 1 No. Incoming And 2 Nos. Outgoing Ht Switchgear And Lt Switchgears Including Foundation
Documents Download All
519661bf-5393-4f59-95d4-afc5d2a03f24
519661bf-5393-4f59-95d4-afc5d2a03f24.pdf
CertificateGCC2022ACSNo
CertificateGCC2022ACSNo.2_1.pdf
Checklist_2
Checklist_2.pdf
GCC_April-2022_27_04_22
GCC_April-2022_27_04_22.pdf
TenderBookofSENENRL
TenderBookofSENENRL.pdf
slNo++;
Sl. No. Item Description
1 <table border=\"1\" class=\"dataframe\"><thead><tr><td>Sl. No.</td> <td>Item Description</td> </tr> </thead> <tbody> <tr><tr><td>1</td><td>(A) Strengthening And Upgradation Power Supply Arrangement In Se & Ne Sections By Providing 110 / 22 Kv Substation, 22 Kv Cabling And Distribution Transformers At Each Stations For General Services Loads. (B) Strengthening And Up Gradation Power Supply Arrangement In Se (Neral) Sections By Providing 22 Kv / 415 V 2 Nos. 250 Kva Compact Substation Comprising Of 1 No. Incoming And 2 Nos. Outgoing Ht Switchgear And Lt Switchgears Including Foundation.</td></tr><tr><td>2</td><td></td></tr></tr></tbody></table>
No Corrigendum
Probable Bidders

AI engine predicts probable bidders to help you bid strategically.

MSME Exception
Explore More →
Technical
Tender involves procurement of high capacity electrical equipment including diaphragm coupling of pump & motor with 90kW capacity at 2900 RPM. The project scope includes installation, testing, commissioning and operational handover.
Previous / Similar Result
BRR : 10184774 The Various Work Related To Strengthening Of 33 / 11 Kv Substations, Setup Tailless Unit Of Dt And Others Work Under Edd-Ist And Iind, Bijnor In Bp 2024-25, Strengthening Of 33 / 11 Kv Sub-Stations And The Work Of Getting Various Works Related To Safety Of Distribution Transformers Etc Done Through External Agency In The Business Plan 2024-25 Under The Area Of ​​Power Distribution Division, First-Bijnor And Second-Bijnor.
Contract Date : Ref. Documents   |   Contract Value : Ref. Documents
BRR : 10293125 Design, Site Preparation, Supply, Installation, Testing, Commissioning, And Amc Services Of Basic Infrastructure For The Establishment Of A Data Center At Centre For Computational And Data Sciences (Ccds), Iit Kharagpur , A. Particulars(Supply) (Price Per Unit In Rs. To Be Entered In The Sl No. 5 And Gst Amount (Per Unit) To Be Entered In Rs. In Sl No. 6) , Civil Works For All Partitions, Fire Rated Glass Works, Doors, False Floor, Road Cutting And Making Good, Building Front Tile Removing Excavation And Filling Up Any Support System, External Wall, Wire Mesh Boundary, Paver Blocks, Wall Breaking And Finishing, External Panel Room. , False Flooring Works (Dc & Electrical Room), Steps & Ramps, Civil And Gypsum Partition, Glass Wall Partitions, Fire Doors, Ante Room, Battery Room Civil Works (Breaking And Finishing Walls), Painting, Finishing, Signages, Branding Works. Grilles/ Tiles Etc. As Required. , Adiabatic Dry Cooler System Along With Pump, Tank, Piping, Controls Panel, Vfd, Pid Controller, Instrumentation As Per P & Id, Adiabatic Tank Etc., Make Up Water , Air Cooled Chiller Plant With Control Panel, Chiller Plant Manager, Auto Restart Feature For Chillers On Restoration Of Power/ Failure Mode, Associated Sensors, Controllers Control Cablings Etc. Pumps, Vfds, Piping Buffer Tanks, Pressurization System, Chemical Dozing System , Chilled Water Pahu With Control Panel, Auto Changeovers, Auto Restart Feature , Chilled Water Rdhx For Data Center Area Along With Flexible Pipes & Controls , Self-Contained Floor Mounted Refrigeration Dehumidifier Derated For 22Oc Operations With Associated Sensors, Controllers Etc. , Ups System With Isolation Transformers For 500Kva And With Incoming And Outgoing Panels As Per Sld. , Ups System With In Built Isolation Transformers For 50Kva With Outgoing Panels As Per Sld. , Li Ion Battery Pack With 10 Minutes Back Up At End Of Life For 500Kva It Loads With 5 Years Warranty , Smf Vrla Battery For Non-It Loads With 15 Minute Back Up , Modification Of Existing Electrical Panels, And Sitc Of Panels And Rest Of Electrical Works As Per Sld. 2 Incoming Panels, 4 Outgoing Panels And Additional Non It Distribution Panel As Required. , End Feed Systems, Bus Ways, Hot Swappable Tap Off Boxes/ Plug In Boxes With 3 X 32A & 1 X16a Iec 60309 Female Receptacles In Each Of 9 Tap Off (2 Spare) Boxes. (Alternative Design May Be Considered To Suit Site/ Bus Ways), 5 Tap Off Boxes (1 Spare) Each With 2 X 40A Plug Ins With Isolators. , Electrical Work As Lighting System Emergency And External Raw Power Lighting, Pump & Dry Cooler Panel Along With Cabling Etc. Earthing Systems With Earth Pits Cable Trays/ Racks/ Etc. Smoke Exhaust System. , I Bms System With Sensors, Cabling, Racks, Computers, Etc. , 800 X 1400Mm/ 1300Mm Racks With Intelligent Pdus With Leveling Etc. Suitable Of 2 Source Power Connections From Top And Provision For Rdhx Installation, Including 2 Sets Of Power Cabling With Connectors To Connect From Tap Off Boxes To Pdu. , Diesel Generator Sets With Day Tanks And Self Standing & Supported Chimneys, Earthing, Fuel Management System, Cabling, Synchronizing Panel, Battery With Chargers, Self Starting, Ats Panel, Fuel Flow Meters And Run Hours With Bms Compatibility For Data Logging. , 2 Years Warrantee For Performance And Workmanship Along With Consumables. , O&M: Deployment Of Onsite Bms, Mep Operators And Supervisor As Per Annexure-K , B. Particulars (Installation) (Price Per Unit In Rs. To Be Entered In The Sl No. 5 And Gst Amount (Per Unit) To Be Entered In Rs. In Sl No. 6) , Civil Works For All Partitions, Fire Rated Glass Works, Doors, False Floor, Road Cutting And Making Good, Building Front Tile Removing Excavation And Filling Up Any Support System, External Wall, Wire Mesh Boundary, Paver Blocks, Wall Breaking And Finishing, External Panel Room. , False Flooring Works (Dc & Electrical Room), Steps & Ramps, Civil And Gypsum Partition, Glass Wall Partitions, Fire Doors, Ante Room, Battery Room Civil Works (Breaking And Finishing Walls), Painting, Finishing, Signages, Branding Works. Grilles/ Tiles Etc. As Required. , Adiabatic Dry Cooler System Along With Pump, Tank, Piping, Controls Panel, Vfd, Pid Controller, Instrumentation As Per P & Id, Adiabatic Tank Etc., Make Up Water , Air Cooled Chiller Plant With Control Panel, Chiller Plant Manager, Auto Restart Feature For Chillers On Restoration Of Power/ Failure Mode, Associated Sensors, Controllers Control Cablings Etc. Pumps, Vfds, Piping Buffer Tanks, Pressurization System, Chemical Dozing System , Chilled Water Pahu With Control Panel, Auto Changeovers, Auto Restart Feature , Chilled Water Rdhx For Data Center Area Along With Flexible Pipes & Controls , Self-Contained Floor Mounted Refrigeration Dehumidifier Derated For 22Oc Operations With Associated Sensors, Controllers Etc. , Ups System With Isolation Transformers For 500Kva And With Incoming And Outgoing Panels As Per Sld. , Ups System With In Built Isolation Transformers For 50Kva With Outgoing Panels As Per Sld. , Li Ion Battery Pack With 10 Minutes Back Up At End Of Life For 500Kva It Loads With 5 Years Warranty , Smf Vrla Battery For Non-It Loads With 15 Minute Back Up , Modification Of Existing Electrical Panels, And Sitc Of Panels And Rest Of Electrical Works As Per Sld. 2 Incoming Panels, 4 Outgoing Panels And Additional Non It Distribution Panel As Required. , End Feed Systems, Bus Ways, Hot Swappable Tap Off Boxes/ Plug In Boxes With 3 X 32A & 1 X16a Iec 60309 Female Receptacles In Each Of 9 Tap Off (2 Spare) Boxes. (Alternative Design May Be Considered To Suit Site/ Bus Ways), 5 Tap Off Boxes (1 Spare) Each With 2 X 40A Plug Ins With Isolators. , Electrical Work As Lighting System Emergency And External Raw Power Lighting, Pump & Dry Cooler Panel Along With Cabling Etc. Earthing Systems With Earth Pits Cable Trays/ Racks/ Etc. Smoke Exhaust System. , I Bms System With Sensors, Cabling, Racks, Computers, Etc. , 800 X 1400Mm/ 1300Mm Racks With Intelligent Pdus With Leveling Etc. Suitable Of 2 Source Power Connections From Top And Provision For Rdhx Installation, Including 2 Sets Of Power Cabling With Connectors To Connect From Tap Off Boxes To Pdu. , Diesel Generator Sets With Day Tanks And Self Standing & Supported Chimneys, Earthing, Fuel Management System, Cabling, Synchronizing Panel, Battery With Chargers, Self Starting, Ats Panel, Fuel Flow Meters And Run Hours With Bms Compatibility For Data Logging. , 2 Years Warrantee For Performance And Workmanship Along With Consumables. , O&M: Deployment Of Onsite Bms, Mep Operators And Supervisor As Per Annexure-K , C. Additional Items (Price Per Unit In Rs. To Be Entered In The Sl No. 5 And Gst Amount (Per Unit) To Be Entered In Rs. In Sl No. 6. These Items Will Also Be Considered For Computing L1) , Comprehensive Annual Maintenance Contract -Year-3 , Comprehensive Annual Maintenance Contract -Year-4 , Comprehensive Annual Maintenance Contract -Year-5 , Operation And Maintenance –Year-3 , Operation And Maintenance –Year-4 , Operation And Maintenance –Year-5
Contract Date : Ref. Documents   |   Contract Value : Ref. Documents
BRR : 9148501 Tender For Operation & Maintenance Of Ehv & Hv Substations And Electrical Maint Of Psx & Tube Well Areas.- 1 Preventive Maintenance Of 132Kv Sf6 Circuit Breakers In Cds Switch Yard 2 Preventive / Breakdown Maintenance Of 132Kv / 11Kv Power Transformers In Cds Switch Yard 3 Preventive / Breakdown Maintenance Of 11Kv / 415 V Distribution Transformers Of Dry And Oil Filled Type In Various Shops Of Cffp. 4 Preventive / Breakdown Maintenance Of Control & Relay Panels In Cds 5 Operation Of Central Distribution Substation In One Shift Jointly With Cds Staff 6 Preventive / Breakdown Maintenance Of 33Kv Vcbs In Cds Switch Yard 7 Preventive / Breakdown Maintenance Of 11Kv Vcbs / Ocbs In Cds 8 Preventive / Breakdown Maintenance Of 11Kv Capacitor Banks In Cds 9 Preventive / Breakdown Maintenance Of 33Kv Capacitor Banks In Cds 10 Preventive Maintenance Of Earthing Installations And Associated Earthing Systems 11 Preventive And Breakdown Maintenance Of Batteries, Battery Chargers And Inverters 12 Making Of End Termination / Straight Through Joints Ht Cables Of Various Sizes ( Pilca Or Xlpe ) 13 Cleaning Of Cable Gallery And Underground Tunnels Of 11Kv And 33Kv 14 Preventive And Breakdown Maintenance Of Various Motors In Psx Area 15 Preventive And Breakdown Maintenance Of Various Starter Panels And Control Supplies In Psx Area 16 Preventive And Breakdown Maintenance Of Various Power Distribution Boards In Psx Area 17 Cleaning And Uprooting Of Wild Growth On Per Square Meter Area Basis In 132 Kv Switch Yard 18 Preventive / Breakdown Maintenance Of 132 & 33 Kv Isolators In Cds Switch Yard. 19 Preventive Maintenance Of 132 & 33Kv Lightning Arrestors And PtS In Cds Switch Yard. 20 Preventive / Breakdown Maintenance Of 132 & 33Kv Current Transformers In Cds Switch Yard. 21 Preventive / Breakdown Maintenance Of 11Kv Main Bus-Sections In Cds And Remote Sub-Stations Like Ds-Ii, Ds-Iii, Ds-Iv And S.Fdy Extn. 22 Operation And Maintenance Of Transformer Oil Filtration Machine In Shifts Jointly With Cds Staff. 23 Misc. Unskilled Work At Cds.
Contract Date : Ref. Documents   |   Contract Value : Ref. Documents
BRR : 10088490 Outsourcing Of Services For Manning And Operation Of E/M Installations At Kavaratti , Androth And Minicoy Under Ge Navy Lakshadweep , Outsourcing Of Services For Manning And Operation Of Electrical Substation Comprising Of Ht 11 Kv Vcb , Transformer 250Kva , Apfc Panels , Lt Switch Gears , Operation Of 3 Nos Gd Sets ( 62 . 5 Kva At Main Power House , 45 Kva At Comcen , Servo Stabilizer 75 Kva At Moc ) And Responsible For Water Supply Pumping For Shallow Wells - 03 Nos To Over Head Tanks , By One ( 01 ) Skilled Electrician Cum Fgm Per Shift Of 8 Hours For Three Shifts In A Day At Ins Dweeprakshak Kavaratti Complete All As Directed By The Engr-In-Charge . , Outsourcing Of Services For Manning And Operation Of Mrs ( Main Receiving Substation ) Comprising Pf Transformers 250 Kva & 100 Kva , Ht 11 Kv 3 Way Rmu , Amf Panles , Apfc Panels Associated Lt Panel Boards/Lt Switch Gears , Switch On Of Dg Sets Of Capacity 30 & 20 Kva During Commerical ( Lakshadweep Electricity Department ) Power Supply Failure And Responsible For Water Supply Pumping/Distribution From Shallow Wells By One ( 01 ) Electrician Cum Fgm ( Skilled ) Per Shift Of 08 Hours For Three Shifts In A Day At Coast Guard Dhq-12 At Kavaratti Complete All As Directed By The Engr-In-Charge . , Outsourcing Of Services For Manning And Opeartion Of Electrical Substation And Installations ( Main Receiving Station ) Comprising Of Ht 11 Kv Rmu , Transformer 250 Kva - 02 Nos , Apfc Panel Associated Lt Panel Boards/Lt Switch Gears , Opeartion Of Dg Set Of Capacity 62 . 5Kva-2 Nos & 25 Kva-1 No During Commericial ( Lakshadweep Electricity Department ) Power Supply Failure , And Responsible For Water Supply Pumping /Distribution From Shallow Wells By One ( 01 ) Electrician Cum Fgm ( Skilled ) Per Shift Of 08 Hours For Three Shifts In A Day At Nd Minicoy Complete All As Directed By The Engr-In-Charge , Outsourcing Of Services For Manning And Opeartion Of Electrical Substation ( Main Receiving Station ) Comprising Of 11 Kv Vcb , Transformer 160 Kva , Apfc Panel Associated Lt Panel Boards/Lt Switch Gears , Operation Of Dg Set Of Capacity 100 Kva During Commerical ( Lakshadweep Electricity Department ) Power Supply Failure And Responsible For Water Supply Pumping /Distribution Form Shallow Wells By Providing One ( 01 ) Electrician Cum Fgm ( Skilled ) Per Shift Of 8 Hours For Three Shifts In A Day At Cg Minicoy Complete All As Directed By The Engr-In-Charge , Outsourcing Of Services For Manning And Opeartion Of Electrical Substaion And Installations Such As Main Receving Station ( Mrs ) Installation Comprising Of Lt Panel Board/Lt Switch Gears , Servo Stablizers , Operation Of Dg Set Of Capacity 62 . 5 Kva During Commercial ( Lakshadweep Electricity Department ) Power Supply Failure And Responsible For Water Supply Pumping/Distribution From Shallow Wells By Providing One ( 01 ) Electricain Cum Fgm ( Skilled ) Per Shift Of 8 Hours For Three Shifts In A Day At Naval Detachment , Androth Complete All As Directed By The Engr-In-Charge , Notes For Item No 1 To 5 Above:- I ) The Manning And Operation Shall Be Done In 3 Shifts ( 0600 To 1400 , 1400 To 2200 & 2200 To 0600 ) In A Day For 330 Days ( Ie 990 Shifts ) Including Weekends And Holidays . The Contractor Shall Follow The Epf & Mp Act And Other Existing Stautory Laws In Force . The Contractor Shall Be Responsible For Arranging Alternate Arrangement Of Manpower During The Holidays/Leave . Ii ) In Addition To The Manning And Operation Work As Specified Above , The Employed Manpower Shall Also Execute The Below Works And The Rate Quoted By Contractor Shall Be Inclusive Of The Same . A ) Checking And Topping Up Of Engine Oil And Waterlevel In Radiator Of Dg Sets In Each Shift . B ) Monitoring And Recording Of Commercial Ht/Lt Voltage Current , Kw , Kwh , Kva And Power Factor Of Commercial Power On Hourly Basis In Log Book Register . C ) Monitoring And Recording Of Dg Set Voltage Current , Kw , Kwh , Kva , Power Factor , Engine Tmperature And Oil Pressure During Dg Set Running On Hourly Basis In Log Book Register . , Continued Notes For Item No 1 To 5 Above:- D ) Maintaing And Filling Out Breakdown Register , Log Book , Attendance Register And Payment Of Wages Register For Each Installation . E ) Daily Checking Of Electrical And Mechnical Connections Of Dg Sets/Transformers/Servo Stabilizers/ Motors Etc To Be Carried Out In Each Shift . F ) Daily Cleaning And Upkeep Of Surrounding Areas Of E/M Insatalltions To Be Operated And Manned By The Manpower .
Contract Date : Ref. Documents   |   Contract Value : Ref. Documents
BRR : 2144903 Corrigendum - Supply , Installation , Testing , Commissioning And One Year Operation And Maintenance Of Power Transformer Along With Allied Electrical Equipments Of 11 Kv Electrical Power Distribution Sub-Station For The 124 Mld Capacity Wtps And Cwps . . . - 2 Supply, Delivery At Site And Storage Of 1500 Kva, 11 Kv / 433 V Onan Indoor Type Transformers With Neutral Brought Out As Per Technical Specification And All Accessories Complete 3 Supply, Delivery At Site And Storage Of 4 Panel, 350 Mva Indoor Type H.T. Vacuum Circuit Breaker As Per Specification With All Inter Connection 4 Supply, Delivery At Site And Storage Of Multi Panel 2500 A Mv Switch Board Connected With The Secondary Side Of 1500 Kva Transformers Suitable For Operation At 415 Volt, 3 Phase, 50 Hz Ac System With All Interconnection Complete As Per Specification 5 Supply, Delivery At Site And Storage Of 110 V, 100Ah, Sealed Maintenance Free Battery Comprising Of 55 Nos., 2 Volts Cells With Float And Boost Charger Cum Dcdb 6 Supply, Delivery At Site And Storage Of 440V, 240 Kvar, 12 Stage Automatic Power Factor Improvement Capacitor Bank ( Apfc ) With All Inter Connection Complete Suitable For 415 V, 50 Hz System As Per Specification 7 Supply, Delivery At Site And Storage Of H.T., M.V. & Control Cable As Per Specification & As Follows 8 I ) H.T. Cable 9 From Wbsedcl’S Summation Panel To Incoming Panel Of Ht Switch Gear Of 11 Kv Grade, 300 Sq Mm Dia, Al Conductor, Xlpe Insulated, Armoured Cable As Per Specification 10 From Ht Switchgear To Two Numbers Of 1500 Kva Transformer Hv Side Terminal Of 11 Kv Grade, 300 Sq Mm Dia, Al Conductor, Xlpe Insulated, Armoured Cable As Per Specification 11 M.V. Cables / Bus Duct 12 From Two Numbers Of 1500 Kva Transformer Secondary Side To The Two Number Of 2500A Incomers Of Mv Switchboard, Bus Duct & Accessories With Adequate Size Of Aluminium Conductor Complete With Sealing As Per Specification & Direction Of E.I.C. 13 From Each Of The 1600 A Outgoing Acb Of 2500 A Substation Mv Switchboard To Respective Incoming Acb Of M.V. Panel At Treatment Plant I.E. Mcc-I, 1.1 Kv Grade, 3.5 C, 300 Sq Mm, Al. Conductor, Xlpe Insulated Armoured Cable, 5 Lengths. 14 From Each Of The 1000 A Outgoing Acb Of 2500 A Substation Mv Switchboard To Respective Incoming Acb Of M.V. Panel At Treatment Plant I.E. Mcc-2, 1.1 Kv Grade, 3.5 C, 300 Sq Mm, Al. Conductor, Xlpe Insulated Armoured Cable, 3 Lengths. 15 From 2500 A Substation Mv Switch Board To Battery Charger, 1.1 Kv Grade, 4 C X 6 Sq Mm Stranded Cu Conductor, Xlpe Insulated Armoured Cable. 16 From Battery Charger / Dcdb To H.T. Panel At Sub Station, 1.1 Kv Grade, 3 C X 2.5 Sq Mm Stranded Cu. Conductor, Xlpe Insulated Armoured Cable. 17 From 2500 A Sub-Station Mv Switch Board To Ventilation System, 1.1 Kv Grade, 4 C X 6 Sq Mm Stranded Cu. Conductor, Xlpe Insulated Armoured Cable. 18 From 2500 A Substation Mv Switch Board To Lighting Db, 1.1 Kv Grade 4 C X 6 Sq Mm Stranded Cu. Conductor, Xlpe Insulated Armoured Cable. 19 From 2500 A Substation Mv Switch Board To Ht Switchgear, 1.1 Kv Grade 3 C X 2.5 Sq Mm Stranded Cu. Conductor, Xlpe Insulated Armoured Cable. 20 Control Cable 21 Stranded Copper Conductor Of Various Ratings And Of Suitable Sizes As Per Specification For All Control Circuit And Interlocking Circuits At Substation 22 Supply, Delivery At Site And Storage Of Jointing Materials As Per Specification & As Follows: 23 All H.T Cables Jointing Materials ( Dry Type, Heat Shrink Joint ) 24 All Mv Cables Jointing Materials For Different Cross Sections ( Dry Type ) 25 All Copper Control & Power Cables Jointing Materials For Different Cross Sections ( Dry Type ) 26 N.B :- No Extra Payment Would Be Made If The Length And Diameter Of The Different Sizes Of Cable & Joints Varies On The Higher Side To Meet Up The Requirement Of The Specification And Site Condition. Rates Must Be Quoted Carefully. This Is Also Applicable For All Type Of Cable Joints. 27 Supply & Delivery At Site And Storage Of Earthing Equipment As Per Specification And All The Other Equipments Required To Comply With Latest I.E. Rules 28 Supply, Delivery At Site And Storage Of Fire Extinguishers As Follows: 29 A-B-C Type ( 5 Kg Each ) 30 Co2 Type ( 4.5 Kg Each ) 31 Supply & Delivery At Site And Storage Of Misc. Items Such As Rubber Mats, Shock Treatment Chart, Danger Boards, Sand Buckets, Glow Sign Board Etc. As Per Specification. 32 Supply & Delivery At Site And Storage Of All Luminaries, Fittings, And Fixtures Complete With Necessary Multi-Strand Copper Wires For Inside Lighting Of Substation As Per Specification. 33 Supply & Delivery At Site And Storage Of Lightning Arrestor Along With Earth Strip And Earth Electrodes All Complete As Per Specification And All Other Equipment Required To Comply With Latest I.E. Rules. 34 Supply & Delivery At Site And Storage Of Spare Parts As Per Specification. 35 Part – B ( Installation Part ) 36 Installation At Site Of 1500 Kva, 11 Kv / 433 V Onan Indoor Type Transformers With Neutral Brought Out As Per Technical Specification And All Accessories Complete 37 Installation At Site Of 4 Panel, 350 Mva Indoor Type H.T. Vacuum Circuit Breaker As Per Specification With All Inter Connection 38 Installation At Site Of Multi Panel 2500 A Mv Switch Board Connected With The Secondary Side Of 1500 Kva Transformers Suitable For Operation At 415 Volt, 3 Phase, 50 Hz Ac System With All Interconnection Complete As Per Specification 39 Installation At Site Of 110 V, 100Ah, Sealed Maintenance Free Battery Comprising Of 55 Nos., 2 Volts Cells With Float And Boost Charger Cum Dcdb 40 Installation At Site Of 440V, 240 Kvar, 12 Stage Automatic Power Factor Improvement Capacitor Bank ( Apfc ) With All Inter Connection Complete Suitable For 415 V, 50 Hz System As Per Specification 41 Installation / Laying At Site Of H.T., M.V. & Control Cable As Per Specification & As Follows 42 I ) H.T. Cable 43 From Wbsedcl’S Summation Panel To Incoming Panel Of Ht Switch Gear Of 11 Kv Grade, 300 Sq Mm Dia, Al Conductor, Xlpe Insulated, Armoured Cable As Per Specification 44 From Ht Switchgear To Two Numbers Of 1500 Kva Transformer Hv Side Terminal Of 11 Kv Grade, 300 Sq Mm Dia, Al Conductor, Xlpe Insulated, Armoured Cable As Per Specification 45 M.V. Cables / Bus Duct 46 From Two Numbers Of 1500 Kva Transformer Secondary Side To The Two Number Of 2500A Incomers Of Mv Switchboard, Bus Duct & Accessories With Adequate Size Of Aluminium Conductor Complete With Sealing As Per Specification & Direction Of E.I.C. 47 From Each Of The 1600 A Outgoing Acb Of 2500 A Substation Mv Switchboard To Respective Incoming Acb Of M.V. Panel At Treatment Plant I.E. Mcc-I, 1.1 Kv Grade, 3.5 C, 300 Sq Mm, Al. Conductor, Xlpe Insulated Armoured Cable, 5 Lengths. 48 From Each Of The 1000 A Outgoing Acb Of 2500 A Substation Mv Switchboard To Respective Incoming Acb Of M.V. Panel At Treatment Plant I.E. Mcc-2, 1.1 Kv Grade, 3.5 C, 300 Sq Mm, Al. Conductor, Xlpe Insulated Armoured Cable, 3 Lengths. 49 From 2500 A Substation Mv Switch Board To Battery Charger, 1.1 Kv Grade, 4 C X 6 Sq Mm Stranded Cu Conductor, Xlpe Insulated Armoured Cable. 50 From Battery Charger / Dcdb To H.T. Panel At Sub Station, 1.1 Kv Grade, 3 C X 2.5 Sq Mm Stranded Cu. Conductor, Xlpe Insulated Armoured Cable. 51 From 2500 A Sub-Station Mv Switch Board To Ventilation System, 1.1 Kv Grade, 4 C X 6 Sq Mm Stranded Cu. Conductor, Xlpe Insulated Armoured Cable. 52 From 2500 A Substation Mv Switch Board To Lighting Db, 1.1 Kv Grade 4 C X 6 Sq Mm Stranded Cu. Conductor, Xlpe Insulated Armoured Cable. 53 From 2500 A Substation Mv Switch Board To Ht Switchgear, 1.1 Kv Grade 3 C X 2.5 Sq Mm Stranded Cu. Conductor, Xlpe Insulated Armoured Cable. 54 Control Cable 55 Stranded Copper Conductor Of Various Ratings And Of Suitable Sizes As Per Specification For All Control Circuit And Interlocking Circuits At Substation 56 Installation At Site Of Jointing Materials As Per Specification & As Follows: 57 All H.T Cables Jointing Materials ( Dry Type, Heat Shrink Joint ) 58 All Mv Cables Jointing Materials For Different Cross Sections ( Dry Type ) 59 All Copper Control & Power Cables Jointing Materials For Different Cross Sections ( Dry Type ) 60 N.B :- No Extra Payment Would Be Made If The Length And Diameter Of The Different Sizes Of Cable & Joints Varies On The Higher Side To Meet Up The Requirement Of The Specification And Site Condition. Rates Must Be Quoted Carefully. This Is Also Applicable For All Type Of Cable Joints. 61 Installation At Site Of Earthing Equipment As Per Specification And All The Other Equipments Required To Comply With Latest I.E. Rules 62 Installation At Site Of Fire Extinguishers As Follows: 63 A-B-C Type ( 5 Kg Each ) 64 Co2 Type ( 4.5 Kg Each ) 65 Installation At Site Of Misc. Items Such As Rubber Mats, Shock Treatment Chart, Danger Boards, Sand Buckets, Glow Sign Board Etc. As Per Specification. 66 Installation At Site Of All Luminaries, Fittings, And Fixtures Complete With Necessary Multi-Strand Copper Wires For Inside Lighting Of Substation As Per Specification. 67 Installation At Site Of Lightning Arrestor Along With Earth Strip And Earth Electrodes All Complete As Per Specification And All Other Equipment Required To Comply With Latest I.E. Rules. 68 Carrying Out Heat Run Of Ht & Mv Equipments, Dehydration Of Transformer Oil And Making Ready All Ht / Mv Equipment For High / Medium Pressure Testing As Per Rule 69 Carrying Out Statutory High Pressure Testing On All Ht Equipment & Medium Pressure Testing On Mv Equipments As Per Specification Including Charges Of Govt. Inspector 70 Charges For Diesel Generator Set / Temporary Power Connection From Wbsedcl / Cesc For Construction Purposes 71 Testing The Whole Installation & Submission Of Test Reports As Per Specification & Direction Of Eic 72 Commissioning The Whole Installation Including Trial Run For 72 Hours On Load Operation As Per Specification & Direction Of Eic 73 Operation & Maintenance Of All Electrical Appliances Installed In The Substation For A Period Of One Year With Adequate Number Of Working Personnel For Round The Clock Operation As Per Requirement And As Per Specification & Direction Of Eic
Contract Date : 20 Mar, 2020   |   Contract Value : 2.59 Crore
Disclaimer

We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.

Tender Detail
Website https://www.ireps.gov.in
Quantity
MSME Exemption No
Tender Type Open Tender
Startup Exemption Click Here
Competitive Bidding NCB
Similar Tenders
TENDER INSIGHTS

858

Electric Tenders
Live
CLICK TO KNOW MAXIMUM WIN

Tell us about your Product / Services,

We will Find Tenders for you

🇮🇳 +91
TenderDetail
Loading tenders