TDR : 36280572
Central Railside Warehouse Company Limited

Tender Brief :

mumbai, Maharashtra

A) Strengthening And Upgradation Power Supply Arrangement In Se & Ne Sections By Providing 110 / 22 Kv Substation, 22 Kv Cabling And Distribution Transformers At Each Stations For General Services Loads. (B) Strengthening And Up Gradation Power Supply

Published: 15 Feb 2023
Opening: Ref Document
Closing: 09 Mar 2023
Amount: 2.35 Crore
EMD: 2.67 Lakhs
Tender Fee: Ref. Documents


Works Active Harmonic Filter Actuator Aerial Cable Aerodrome Beacon Air Circuit Breaker
0
Days Left
Tender Summary / Eligibility Criteria
A ) Strengthening And Upgradation Power Supply Arrangement In Se & Ne Sections By Providing 110 / 22 Kv Substation, 22 Kv Cabling And Distribution Transformers At Each Stations For General Services Loads. ( B ) Strengthening And Up Gradation Power Supply Arrangement In Se ( Neral ) Sections By Providing 22 Kv / 415 V 2 Nos. 250 Kva Compact Substation Comprising Of 1 No. Incoming And 2 Nos. Outgoing Ht Switchgear And Lt Switchgears Including Foundation
Documents Download All
519661bf-5393-4f59-95d4-afc5d2a03f24
519661bf-5393-4f59-95d4-afc5d2a03f24.pdf
CertificateGCC2022ACSNo
CertificateGCC2022ACSNo.2_1.pdf
Checklist_2
Checklist_2.pdf
GCC_April-2022_27_04_22
GCC_April-2022_27_04_22.pdf
TenderBookofSENENRL
TenderBookofSENENRL.pdf
slNo++;
Sl. No. Item Description
1 <table border=\"1\" class=\"dataframe\"><thead><tr><td>Sl. No.</td> <td>Item Description</td> </tr> </thead> <tbody> <tr><tr><td>1</td><td>(A) Strengthening And Upgradation Power Supply Arrangement In Se & Ne Sections By Providing 110 / 22 Kv Substation, 22 Kv Cabling And Distribution Transformers At Each Stations For General Services Loads. (B) Strengthening And Up Gradation Power Supply Arrangement In Se (Neral) Sections By Providing 22 Kv / 415 V 2 Nos. 250 Kva Compact Substation Comprising Of 1 No. Incoming And 2 Nos. Outgoing Ht Switchgear And Lt Switchgears Including Foundation.</td></tr><tr><td>2</td><td></td></tr></tr></tbody></table>
No Corrigendum
Probable Bidders

AI engine predicts probable bidders to help you bid strategically.

MSME Exception
Explore More →
Technical
Tender involves procurement of high capacity electrical equipment including diaphragm coupling of pump & motor with 90kW capacity at 2900 RPM. The project scope includes installation, testing, commissioning and operational handover.
Previous / Similar Result
BRR : 9513897 Tender for Kalpi Npp Water Supply Scheme District Jalaun Construction Of Intake Footbridge Wtp Oht Rising Main Distribution System And Electrical Mechanical Works Under Kalpi Npp Water Supply Scheme District Jalaun - W.T.P -Design (hydraulic and structural ), construction, (including topographical survey, geotechnical investigation and other Surveys as required) for specified capacity of WTP based on 20 Hrs. operation including inlet chamber, aeration fountain / cascade, inlet channels ,chemical building ,including mechanical/manual fine/coarse screens, flash mixer, mixing channel with Parshall flume and flow measuring arrangement, clariflocculator with conventional, filter house and filter plant including back wash tank and back wash pumps with 100% standby, chemical house, coagulant feed tank with feed mechanism, poly aluminium chloride (PAC) or other coagulant tank of specified capacity and nos. with mixing and dosing arrangement complete, vacuum feed gas chlorinator with 100% standby ,safety equipment’s &EOTcrane,pressureandleveltransmitterfor pumpingplant,turbidity, TDS, PHAnalyzer,chlorineanalyzer,ROFTandLOHTforfilter house,flowtransmitterultrasonic/electromagneticatinletandoutletandFilter backwashwithentirepipingsystem , sludge handling unit and recycling of collected water from sludge , etc. complete to achieve desired perameters of clear wateras specified in tender document andin accordace letest C.P.H.E.E.O.Manual,/ltest guidline/ I.S. Codes/Govtt. Orders . All WTP scada Opratedexternal and internal electrification, laboratory building with all specified lab equipment, admin building,Sub station building (L.T./H.T. Room), Platform for Transformer,Meter Room ,chlorine Room,Staff Quarter (Type III-one Number), sanitary block with necessary water supply and drainage arrangement, campus roads (Interlocking Road/C.C.Road), landscaping( earth filling up to 115.00level including levelling and dressing of Campus )and other campus development works with rain water harvesting and garden, etc. all required works complete as per the direction of Engineer-in-Charge in Pile Foundation .The WTP shall be fully automatic prefrablybased onRapid sand gravity filter or any proven technologysuitable to treat Raw water from yamuna river throug out the year , PLC/SCADA with real time remote monitoring system and online contineuous effluent monitoring systemincluding Soil testing, Design ,S/o all labour ,material T&P etc. required for proper completion of the work as per letest IS Codes ,manuals ,instruction of engineer in charge and tender document. 2 INTAKE WELL- Supply of all materials, labour, T&P etc.as requiredforDesign and construction of Intake- well - cum - pump house of 9.0 m. internal dia. The intake well upto floor level shallbe firmly based on suitable foundation made with well sinking tecgnology including construction of coffer damand Annular raft/ well foundation , including construction of 1.20 m. wide R.C.C. balcony at plinth level, construction of Pump House made of brick masonry, duly embraced within R.C.C. column, and fitting of doors and windows, making opening arrangement at floor level of pump house (9.00 m. dia and 6 m. height)and construction of 1.20 m. wide R.C.C. balcony at Pump house floor levelincluding S.S. Rolling Shutter, steel cage hinged with locking arrangement, duly supported on steel girder. Plateform for transformer ,meter room andSubstation Building (HT pannel room,LT pannel room ) Ventilator arrangement along with fixing of required size dia. DID/F pipesand Sluice Valves- 3 Noat inlet etc. as per site requirement or as per the design. The work also includes steelrailing(grad 304 ) in three rows on both sides of pump house balcony and fixing of 0.5m. wide M.S. ladder made of 50 x 50x 6mm. angle iron ladder from floor of pump house to floor of intake well, duly supported on R.C.C.landing at suitable interval. The ladder shall run spirally inside the intake well and each landing shall be supported on R.C.C. M.S. channelpost, spaced not more than 1.5 m. interval including Construction of R.C.C. foundation block as required also include provision for dismantling and reinstatement of stone pitching,removal earth of Coffer dam to maintain flow through-out the year ,Approch roadup to Approch bridge etc up to completion of work as per insrtuction of engineer in charge and tender document . 3 The floor of pump house & balcony shall be of Kota Stone etc. complete. Frames for doors / Shutter shall be made of 50x50x5 mm. M.S. angle iron and ionized and shall be partly panelled and glazed, made of suitable steel sections, conforming to relevant BIS. The work also includes painting of all concrete surfaces with three coats of approved paint and painting of pipes, doors, windows with anticorrosive paints including design of intake well, foot bridge, pump house etc. considering seismic and other forces as per relevant BIS requirements. 4 Design and construction of 4.0 mts. wide R.C.C Foot bridge from Intake well to bank of river for length of 350 mtsminimum height of foot over bridgeslab should be equal to level of floor level of Pump House. pier of bridge in well shinking foundation minimum two Beam below deck slab with bearing support. Provision for padestal construction to rising main pipe fixing with anchor Clamping ,casing pipe for electric cables . Also including Supply& fixing ofstainless steel (gread 304) railing both sides of foot bridge , floor shall be plain chequered tiles, Statinless steel gate at entry gate of Approch bridge with locking arrangmentsup to completion of work as per insrtuction of engineer in charge and tender document . 5 Construction of R.C.C Over Head Tank (OHT)Supply of all the materials, labour T&P and construction of a R.C.C. Over head tank above ground level with main components, based on IS-3370 and IS 11682 or liquid storage concrete in over head tank and foundation concrete as per specification in I.S. 2911.Following capacity/StagingAll Components of OHT will be casted in M-30 concrete with cement, coarse sand and approved stone grit asI.S. 456.Minimum depth of founditation below original ground level will be 2.0 M and in pile Foundation .Seismic effects and wind load should be taken into consideration as I.S. 1893for earthquake resistance and I.S. 875 part-III for wind load on structure. The asumed bearing capacity of soil has been taken as 8 M.T. sqm.1m wide RCC stair case from ground lavel to balcony.M.S. ladder made of 50 X 50 X 6 mm angle section and 20 mm plain M.S. bars (specification of M.S. should be as per IS 800-2007) with hand rails of 20 mm medium class G.I. pipes on both sides in three rows from balcony to top dome resting on an RCC plateform (75 X 75 cm and 10 cm thick) projecting from top ring beam and one alluminium ladder inside the tank body (from manhole to tope domto bootom dome). 6 1 m wide R.C.C. balcony around the tank at the junction point of vertical wall and conical wall.Proper R.C.C. railing and 20 mm dia medium class G.I. pipe (in 3 rows) on both sides of stair case, arround the balcony at each landing from landing with top ring beam upto manhole on the top dome and at the periphery. The G.I. pipes will be supported on R.C.C. postsof 100 mm dia or on the posts made of 50 X 50 X 6 mm M.S. angle section, spaced at intervals not more than 1.5 m.Proper ventilator at top dome in circular shape of 1.2 m dia along with an R.C.C. cover of minimum 1.50 m dia and 7.5 cm thickness, pillar of vintilator should be minimum 50 cm dia. The space between top dome and R.C.C. cover should be covered with mosquito net of standered qualitity along with expended mentaled jail.Electro Megnatic Flow Meter.Lightening conductor as per I.S.S. 2309 of its latest amendments of latest electricity rules. It should consistproper elevation rod with 5 or more fork points proper down conductors of prescribed mental of proper size prescribed by ISS 2309-1969 and ISS 3013-1966.D.I. manhole of min 60 X 60 cm size made of M.S. channel section with adequate cover made of M.S. sheet of minimum 3mm thickness hinged with manhole with locking arrangment. This manhole should be fixe at top dome at proper place.including soil testing from govt institute as per tender document andrelevent IS codes. 7 Zone -1 1300KL/22M 8 Zone -21100KL/25M 9 Zone -3 2400KL/22M 10 Zone -4 300KL/25M 11 CONSTRUCTION OF R.C.C CLEAR WATER RESERVIOUR (C.W.R) CUM PUMP HOUSE OF VARIOUS AT DIFFERENT SITE Design & supply of allmaterial T&P etc and constructRCC CWR cum pump house offollowing capacity with HT, L.T and meter room, GI pipes railling consisting of 3 rows of 20 mm dia G.I pipe and angle iron posts of the dome periphery, S.S ladder from ground level to top of tank and inside the tank, locking device, ventilator, supply and fixing digital level indicator, 25mm PCC 1:2:4 over 80mm PCC 1:4:8 in apron, 150 mm semicircular drain around the tank, two coats of apex paint and testing of tank for water tightness etc. and also including the cost of supply and fixing of all necessary pipes and valves etc all complete as per approved design and drawing.including soil testing from govt institute as per tender document andrelevent IS codes. 12 1200kl (MCWR) 13 Demolition of R.C.C Over Head Tank (OHT)Dismantling of ESRs of various capacities and heights using crane (10 MT capacity) and handing over M.S./ C.I./G.I. pipes, valves, bends, etc. to the Department. However taking steel reinforcement by the dismantling agency and other defung buildings like staff quarters, damaged pump house including removing dismantled materials from site and disposing them at suitable place as directed, etc. complete.Capacity of E.S.R. upto 2 lakh litres and staging upto 12 M heightZone -1 500KL/12M 14 Zone -2 -400KL/12M 15 Raw Water Rising Mains From Intake To WTPExcavation for pipe line in ordinary soil (loam, clay, sand) with lift up to 1.5 m and lead up to 50 m and including filling back, watering and ramming of excavated earth into the trenches and removal and disposal of surplus earth within 50 meters. 16 500 mm DI K-7(yamuna river to WTP) 17 Supply of ISI mark DI K-7 S&S pipes (push on joints) with supply of allDI specials of following class and diameters inclusive of jointing material (Rubber gasket of EPDM Quality IS 12820 / 1989) conforming to IS 8329/2000 for its latest ammendment F.O.R. desination rates per meter (exclusive of GST) in Rs. every where in UP upto stores of consignees inclusive of third party inspection chacking and forwarding charges, transit insurance charges, road transportation charges, unloading & stacking the same etc. complete 18 500 mm DI K-7(yamuna river to WTP) 19 Lowering, laying and jointing with ruber gasketsD.I. K-7/ D.I. K-9 of various classes with DI / MS specials of following diameter in proper position also fixing of pipe on foot over bridge, grade and alignment including conveyance of material to site of work. It also includes cost of jointing materials and rubber rings labour,hydraulic testing etc. complete. 20 500 mm DI K-7(yamuna river to WTP) 21 Supply of following type of valves as per specifications F.O.R. desination rates per meter (exclusive of GST) in Rs. every where in UP upto stores of consignees inclusive of third party inspection charges, packing and forwarding charges, transit insurance charges, road transportation charges, unloading & stacking the same etc. complete. 22 Double flanged Ductile Iron Sluice valves as per IS 14840 : 2000 - 500 mm 23 -Air valves as per IS 14845 : 2000-100 mm 24 Carting, lowering, laying, aligning, fixing in position and installation of following valves in pipe line including all material, labour, testing and commissioning as per direction of Engineer-in- charge. 25 Double flanged Ductile Iron Sluice valves as per IS 14840 : 2000 - 500 mm 26 Kinetic Double Air Valves-Air valves as per IS 14845 : 2000-100 mm 27 R.C.C. Thrust block with cement, core sand, and 20mm gauges stone ballast in propotion of 1: 1.5:3 in thrust block of pipe line including reinforcementand its bending the same with 0.08 mm thick binding wire in position and necessary shuttring including proper curing and supply of all materials, labour and T&P etc required for proper completion of work. 28 Providing reinforcementincluding cutting bending, hooking the bars, binding with wires or tack welding and supporting as required etc. complete (including cost of binding wire and MS Bar) 29 Supply of all materials, labour, T&P etc. required for construction of following masonry type chambers as per type design. 30 Sluice valve Chamber 500mm 31 Air valve Chambers -Air valves as per IS 14845 : 2000-100 mm 32 Rising MainsSupply of ISI mark DI K-7/K-9 S&S pipes (push on joints) of following with D.I. specials and diameters inclusive of jointing material (Rubber gasket of EPDM Quality IS 12820 / 1989) conforming to IS 8329/2000 for its latest ammendment F.O.R. desination rates per meter (exclusive of GST) in Rs. every where in UP upto stores of consignees inclusive of third party inspection chacking and forwarding charges, transit insurance charges, road transportation charges, unloading & stacking the same etc. complete 33 125 D.I K-9 34 200 D.I K-9 35 350 D.I K-9 36 400 D.I K-9 37 Excavation for pipe line in ordinary soil (loam, clay, sand) with lift up to 1.5 m and lead up to 50 m and including filling back, watering and ramming of excavated earth into the trenches and removal and disposal of surplus earth within 50 meters.0 to 1.5 m depth 38 Lowering, laying and jointing with SBR ruber gasketsD.I. K-7/ D.I. K-9 of various classes with DI / MS specials of following diameter in proper position, grade and alignment including conveyance of material to site of work. It also includes cost of jointing materials and rubber rings labour,hydraulic testing etc. complete. 39 125 D.I K-9 40 200 D.I K-9 41 350 D.I K-9 42 400 D.I K-9 43 Supply of following type ofDI valves as per specifications F.O.R. desination rates per meter (exclusive of GST) in Rs. every where in UP upto stores of consignees inclusive of third party inspection charges, packing and forwarding charges, transit insurance charges, road transportation charges, unloading & stacking the same etc. completeDouble flanged Ductile Iron Sluice valves as per IS 14840 : 2000./Air valves as per IS 14845 : 2000 including Sluice valve of Isolation 44 125 mm D.I D.F. 45 200 mm D.I D.F. 46 350mm D.I D.F. 47 400 mm D.I D.F. 48 25 mm D.I D.F. 49 50 mm D.I D.F. 50 80 mm D.I D.F. 51 Carting, lowering, laying, aligning, fixing in position and installation of following valves in pipe line including all material, labour, testing and commissioning as per direction of Engineer-in- charge.Double flanged Ductile Iron Sluice valves as per IS 14840 : 2000 /Air valves as per IS 14845 : 2000 52 125 mm D.I D.F. 53 200 mm D.I D.F. 54 350mm D.I D.F. 55 400 mm D.I D.F. 56 25 mm D.I D.F. 57 50 mm D.I D.F. 58 80 mm D.I D.F. 59 Supply of all materials, labour, T&P etc. required for construction of following masonry type chambers as per type design. 60 Sluice valve Chamber (MASONRY TYPE) 61 Air Valve Chamber 62 R.C.C. Thrust block with cement, core sand, and 20mm gauges stone ballast in propotion of 1: 1.5:3 in thrust block of pipe line including reinforcementand its bending the same with 0.08 mm thick binding wire in position and necessary shuttring including proper curing and supply of all materials, labour and T&P etc required for proper completion of work. 63 MS work in plain RCC incluiding bending supply wastage overlaping etc complete 64 Provision for crossing of Nalas/culvert for laying of pipe line usingsuitable dia. and length 0.60 m more than the outer width of nala, labour, T&P, necessary arrangement for diversion & pumping of water if required, barricading etc required for proper completion of work as per directions of engineer-in-charge.(up to 3.50m wide) 65 NHAI crossing by trenchless technologyProviding and laying of 700 mm dia MS casing pipe 12 mm thick by trenchless technology under railway track with outside PU coating of 1000 micron and inside PU Coating of 500 micron alongwith Providing & Laying of Carrier pipe of dia 400 mm, 8.0 mm thick with outside PU coating of 1000 micron & inside PU Coatingof 500 micron including, providing and fixing of speed restriction caution board as per railway norms and 80 mm. dia GI drain and vent pipe, Providing and fixing the end seal on both ends to plug the annular space between casing and carrier pipe & under ground probe radar survey to check any underground abstruction before finalizing the alignment and to take precautionary measures from power supply distribution. 66 Railway crossing by trenchless technologyProviding and laying of 250 mm dia MS casing pipe 12 mm thick by trenchless technology under railway track with outside PU coating of 1000 micron and inside PU Coating of 500 micron alongwith Providing & Laying of Carrier pipe of dia 125 mm, 8.0 mm thick with outside PU coating of 1000 micron & inside PU Coatingof 500 micron including, providing and fixing of speed restriction caution board as per railway norms and 80 mm. dia GI drain and vent pipe, Providing and fixing the end seal on both ends to plug the annular space between casing and carrier pipe & under ground probe radar survey to check any underground abstruction before finalizing the alignment and to take precautionary measures from power supply. 67 Dismantling of following type of road surfaces for laying of pipe line n work including sorting out of serviceable materials and disposal of unserviceable materials. 68 Bituminious Road 69 Cement Concrete Road 70 Re-instatement of following type of road surfaces after laying of pipe linework including supply of all materials, labour, T&P etc. requuired for proper completion of the work as per direction of engineer-in-charge. The quantity of re-instatement has been increased by thirty percent in the view of additional damaged of dismantled road due to traffic / vehicle movement. 71 Bituminious Road 72 Cement Concrete Road 73 Distribution Network .Supply of ISI Marked or its relevant code HDPE Pipes and Electrofusion specialsof follwing sizes (Dia in mm) with jointing materials, specials of sizes required during constructionas per latest I.S.Samandement upto site of work included loading unloading cartage insurance, etc all completed but exclusive of GST in various zone as per the drawing and approval to Engineer 74 HDPE PIPE GRADE PE 100/ PN 6- 90 mm 75 HDPE PIPE GRADE PE 100/ PN 6- 110 mm 76 HDPE PIPE GRADE PE 100/ PN 6- 140 mm 77 HDPE PIPE GRADE PE 100/ PN 6- 160 mm 78 Supply of ISI Marked or its relevant code DI K-7 Pipes and Specials of follwing sizes (Dia in mm) with jointing materials, during construction as per latest I.S amendement upto site of work included loading, unloading, cartage insurance, etc all completed but exclusive of GST in various zone as per the drawing and approval to Engineer 79 D.I. K-7/ 200 mm 80 D.I. K-7/ 250 mm 81 D.I. K-7/ 300 mm 82 D.I. K-7/ 350 mm 83 D.I. K-7/ 400 mm 84 D.I. K-7/ 450 mm 85 Supply of following size ofSluice Valves/ Scour Valves,capable for working pressure of 10 kg/cm2 Fire hydrants & Air Valves as per relerelavent I.S.I or its latest amandement. Up to store Including loading, unloading & cartage, taxes duties insurance etc all complete. As per IS: 2906-1969. /Air Valve as per as I.S : 14845D.I. D/F Sluice valve/ Scour valve 86 25 mm. dia DI D/F 87 50 mm. dia DI D/F 88 100 mm. dia DI D/F 89 150 mm. dia DI D/F 90 200 mm. dia DI D/F 91 250 mm. dia DI D/F 92 350mm. dia DI D/F 93 Fire hydrant (80 mm dia.) 94 Excavation for pipe line trenches in Ordinary soil requiring use ofspecialT&P etc. with lift upto 1.5 m lead upto 50 mincluding filling back of excavated earth into trenches and watering ranmming dressing and removal of surpluas earth upto 50.m including supply of alllabour T&P etc complete and as per direction of engineer incharge. 95 Cartage fromstore to site of work for following size (dia in mm)HDPE pipes andElecrofusion Specialsand lowering the same into trenches and laying true to alignment and gradiant including testing of pipe lines cuttings of pipes for making up the length and making joints with electrofusion couplers, bands, tees, endcap etc. with electrofusion machinery including all jointing materials, labour, T&P etc required for proper completion of work. (excluding cost of trenching) 96 HDPE PIPE GRADE PE 100/ PN 6- 90 mm 97 HDPE PIPE GRADE PE 100/ PN 6- 110 mm 98 HDPE PIPE GRADE PE 100/ PN 6- 140 mm 99 HDPE PIPE GRADE PE 100/ PN 6- 160 mm 100 Cartage of DI K-7 pipes and specials of following size (dia in mm) , lowering them into trenches and laying true to alignment and gradiant including testing of pipe line but excluding cost of trenching including all supply of Labour T&P etc complete required for proper completion of work. 101 D.I. K-7/ 200 mm 102 D.I. K-7/ 250 mm 103 D.I. K-7/ 300 mm 104 D.I. K-7/ 350 mm 105 D.I. K-7/ 400 mm 106 D.I. K-7/ 450 mm 107 Carting of following size of Sluice Valves/ Scour Valves Fire hydrants & Air Valves from store to site of work and lowering them into the trenches, fixing in position and jointing them with Pipe line and testing etc including supply of jointing materialand also including supply of all material and construction of suitable P.C.C Support below fittings etc. complete.D.I. D/F Sluice valve/ Scour valve/ air valve 108 25mm dia 109 50 mm dia 110 100 mm dia. 111 150 mm dia. 112 200 mm dia. 113 250 mm dia. 114 350 mm dia. 115 Fire hydrant (80 mm dia.) 116 R.C.C. Thrust block with cement, core sand, and 20mm gauges stone ballast in propotion of 1: 1.5:3 in thrust block of pipe line including reinforcementand its bending the same with 0.08 mm thick binding wire in position and necessary shuttring including proper curing and supply of all materials, labour and T&P etc required for proper completion of work. 117 Thrust Block 118 Supply of all matarial labour T&P etc and constuction of following type of chamber as per type design & drawing & as per diretion of engineer incharge . 119 Sluice valve chamber 120 Scour Valve Chamber 121 Air Valve chamber 122 Fire hydrant chamber 123 Flow Meter chamber 124 Provision for Nala/ Culvert crossing including all materials, labour and T&P etc. complete. It includes supply of D.I. pipe of necessary size for encasing, cement concrete and Brickwork for pillars and any other job for proper completion of work. 125 For crossing ofnalla/culvert upto 3.5 m wide(90mm dia to 110mm dia ) 126 For crossing ofRoad upto3.5 m wide(90mm to 110mm ) 127 For crossing ofRoad upto7.0. m wide(90mm to 110mm) 128 Dismantling of following types of roads including sorting out of servicable matarials stacking and disposal of unservicable matarials with in a distance of 50 m. including supply of labour specials T&P etc. required for proper completion of work 129 Interlocking tile 130 C.C Road 131 Bituminous Road 132 B.O.E Road 133 Reinstatement of following types of roads including sorting out of servicable matarials stacking and disposal of unservicable matarials with in a distance of 50 m. including supply of required new matarials & reinstatement the same includng supply of labour T&P etc. required for proper completion of work. 134 Interlocking tile 135 C.C Road 136 Bitumenous Road 137 B.O.E Road 138 NEW HOUSE CONNECTIONMaking House Connectionwith Distribution main with elecrofusion saddle and fittings ,brass ferrule and Tap ,HDPE /GI pipe , including Reinstatement of road after Dismantling of road , supply, cartingofspecialsloweringtheminto trenches , fixing them including bailing out of water necessary excavation for connection including all labour , T&P etc. required for proper completion of the work as per instruction of engineer in charge and tender document. 139 In C.C. Roads 140 For 90 mm to 110mm dia 141 For 125 mm to 160 mm dia 142 For 200 mm to 250 mm dia 143 For 300 mm to 350mm dia 144 For 400 mm to 500mm dia 145 In Bitumenous Roads 146 For 90 mm to 110mm dia 147 For 125 mm to 160 mm dia 148 For 200 mm to 250 mm dia 149 For 300 mm to 350mm dia 150 For 400 mm to 500mm dia 151 In B.O.E. Roads 152 For 90 mm to 110mm dia 153 For 125 mm to 160 mm dia 154 For 200 mm to 250 mm dia 155 In C.C. Interlocking Tiles Roads 156 For 90 mm to 110mm dia 157 For 125 mm to 160 mm dia 158 For 200 mm to 250 mm dia 159 For 300 mm to 350mm dia 160 For 400 mm to 500mm dia 161 In Kacha Roads 162 For 90 mm to 110mm dia 163 For 125 mm to 160 mm dia 164 For 200 mm to 250 mm dia 165 For 300 mm to 350mm dia 166 SHIFTING OF HOUSE CONNECTIONMaking House Connection with Distribution mainwith elecrofusion saddle and fittings ,brass ferrule and Tap ,HDPE /GI pipe ,including Reinstatement of road after Dismantling of road , supply, cartingofspecialsloweringtheminto trenches ,fixing them including bailing out of water necessary excavation for connection including all labour , T&P etc. required for proper completion of the work as per instruction of engineer in charge and tender document. 167 In C.C. Roads 168 For 90 mm to 110mm dia 169 For 125 mm to 160 mm dia 170 For 200 mm to 250 mm dia 171 For 300 mm to 350mm dia 172 For 400 mm to 500mm dia 173 In Bitumenous Roads 174 For 90 mm to 110mm dia 175 For 125 mm to 160 mm dia 176 For 200 mm to 250 mm dia 177 For 300 mm to 350mm dia 178 For 400 mm to 500mm dia 179 In B.O.E. Roads 180 For 90 mm to 110mm dia 181 For 125 mm to 160 mm dia 182 For 200 mm to 250 mm dia 183 In C.C. Interlocking Tiles Roads 184 For 90 mm to 110mm dia 185 For 125 mm to 160 mm dia 186 For 200 mm to 250 mm dia 187 For 300 mm to 350mm dia 188 For 400 mm to 500mm dia 189 In Kacha Roads 190 For 90 mm to 110mm dia 191 For 125 mm to 160 mm dia 192 For 200 mm to 250 mm dia 193 For 300 mm to 350mm dia 194 Building worksSupply of all materials, labour, T& P, complete and construnction of a Half set of One No.Single Roomed staff quarters for Operator staff, pump operator, chaukidaar, pump attendent and other as per approved design in pile Foundation. 195 Zone-1 196 Zone-2 197 Zone-3 198 Zone-4 199 At wtp campus 200 Supply of all materials, labour, T& P, complete and construnction other as per approved design in pile Foundation.For Construction of general resedential staff quarters(type-II) 1nos of 2 half set of area 57.70sqm. 201 Supply of all materials, labour, T& P, complete and construnction other as per approved design in pile Foundation for Construction of following type of ancliary buildings Master Control Room(5x4.5x4m) 202 Construnction of Boundary Wall including supply all materials, labour, T&P etc required for proper completion of work as per Approved design in pile foundation. 203 Water Campus Zone 1 204 Water Campus Zone 2 205 Water Campus Zone 3 206 Water Campus Zone 4 207 AT wtp campus 208 Supply and fixing 3.60 M & 1.20 M wide MS Gate with pillars including fabrication and supply of steel and construnction ofboundary pillars etc complete. 209 Provide all materials, labour, T&P etc Required for proper completion of work and construct Interlocking Tiles approach road, laid dry and joints intact with coarse sand mortar including preparation of base etc 210 Water Campus Zone 1 211 Water Campus Zone 2 212 Water Campus Zone 3 213 Water Campus Zone 4 214 Construnction of Drain in Water works Campus30 x 30 cm including labour material and t&p all complete 215 Zone-1 216 Zone-2 217 Zone-3 218 Zone-4 219 Filling of earth of lower portion including levelling and dressing at water works 220 E&M works 221 RAW WATER PUMPING PLANT ATINTAKE WELL 222 Supply of Vertical type oil lubricated statically, dynamically, hydraulicallybalancedturbinepumpcapableofdischargingat980 rpm the following duty condition as given below due to all causes with surface discharge head confirming to IS:1710 and as amended as on date with accessories as per IS 5120/1977(Reconfirmed 2011) and as amended thereafter to suit the site condition.The Pump Bowl assembly shall be FG: 260with 2% NiCi with CF8M impeller running at 980 rpm., head shaft, SS-410 line shaft , Rubber line shaft bearing , C.I. Bearing retainer, Suction bell mouth, strainer, oil tube and 24mtr/suitablelengthcolumnassembly,withverticalSolidshaft Squirrel cage induction motor copper wounded and die cast copper rotor (IS:126152011/IEC 60034-1) suitable for the above pump continuousratedTEFCIP-55withClassFinsulation,antirotation locking arrengementfor operation in AC, three Phase/50 HZ (±5%), 415V (±10%), running with a speed of pump.CAPACITY:- 6000 LPM / 35 Mtr. HEAD / 75 HP MOTOR (2w+1s) 223 MAIN PIPING AND VALVES :- 224 Supplyof250 mm dia DIDFSingleDoor/MultiDoorNonreturn/refluxvalve conforming to IS:5312/2003(part I & II) PN-1.0 to be fixed after pumps for 90% fast closing & 10% slow closing . 225 SupplyofDIDFsluicevalvewith Electricallyintegratedactuater (Totally enclosed, weather-proof and dust proof construction with IP- 67 (IP-68 for field installation),protectionclasssuitableforinstallation inanypositionwithout lubrication, leakage or other operational difficulty with special grease filledgearboxandsuitableformanualoperationforemergency which will automatically dis-engage on restoration of power to motor andwith10wattsinglephasespaceheaterandcontinuouslocal mechanicalpositionindicatorandindividuallyreplaceablecounter gear assembly and with two torque and four limit switches with S.S. flapandoperatedwithgeardrivencamsandofrating250Volt,5 Amp, AC/DC, torque switch dial and with TEFC squirrel cage induction) operated with positioning card suitable to SCADA operation sluice valve havingBody : DI GGG 40 / IS 1865 Gr. 400/15, Wedge : DI GGG 40 /IS 1865 Gr. 400/15, Dome : DI GGG 40 / IS 1865 Gr. 400/15, Wedge Nut: Brass / Al. Bronze , Spindle : SS AISI 410 , Seat Rings : LTB IS : 318 Gr. LTB 2,Spindle Nut : LTB IS : 318 Gr. LTB 2 .Valves generally conform to IS:5312.Flanges to be drilled as per IS:1538 Part-IV &VI.Valvesare suitablefor hydrostatictestpressureof10Kg./Cm2forseatand15Kg./Cm2for body(PN-1.0)of following sizes 226 250 mm dia size at Pump delivery 227 350 mm dia size at common header 228 SupplyofDIDF manuallyoperatedsluicevalvehavingBody : DI GGG 40 / IS 1865 Gr. 400/15, Wedge : DI GGG 40 /IS 1865 Gr. 400/15, Dome : DI GGG 40 / IS 1865 Gr. 400/15, Wedge Nut: Brass / Al. Bronze , Spindle : SS AISI 410 , Seat Rings : LTB IS : 318 Gr. LTB 2,Spindle Nut : LTB IS : 318 Gr. LTB 2 .Valves generally conform to IS:5312.Flanges tobedrilledasperIS:1538Part-IV&VI. Valves aresuitable for hydrostatic test pressure of 10Kg./Cm2 for seat and 15Kg./Cm2 for body(PN-1.0 Rating) Sluice Valve of 350 mm dia size at By-pass 229 Supply and fabrication of main piping of following sizes350 x 250 x 350 mm MS D/F Tee (10 mm thickness) -3 No250 mm MS D/F Pipe 0.50 mt. (10 mm thickness) - 3 No 250 mm MS D/F Pipe 1.00 mt.(10 mm thickness) - 3 No 350 mm MS D/F Pipe 1.00 mt.(10 mm thickness) - 3 No 350 mm MS D/F Pipe 2.00 mt. (10 mm thickness) -1 No 350 mm MS D/F (10 mm thickness) Bend 90o - 2 No 350 mm Blind Flange - 1 NoNecessary G.I. Nut Bolt’s & Rubber Packing - 1 Lot 230 SupplyofD.I./D.F.DismantlingJointsisavariablelengthDouble Flanged Short Piece constituted by a flange / Spigot Tailpiece inserted into the other Tailpiece which allows the distance between the two flangestobevariedwithincertainlimitsthusprovidingavariable distance piece between two fixed flange end devices like Pumps and Valves. The Dismantling Joint to be supplied complete with Sealing RubberGasketsofEPDMquality(IS:5382/1985Type-4),CastIron Follower Glands and Mild Steel (Zinc Coated) Nut Bolts of Following size 231 Dismantling joint 200 mm dia size at pump delivery 232 Dismantling joint 350 mm dia size at common header 233 Suitable capacity heavy duty handoperatedoverheadTravelling(HOT)crane suitable for a span upto 6 Mtrs, and travel length upto 10 Mtrs. with clear lift upto 6 M including gear type chain pulley block and geared Travelling trolley complete with all accessories including girder. 234 MOTOR CONTROL CENTER (MCC) PANEL :-Singlefront,Indoor&floormounted,cubicaltypePanelfactory fabricated(2mmthickforsructure,1.6mmthickfordoor,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coated dust andvermin proof IP-54 /IS:2147, consideredEarth Bus-Bar-Copper Strip compitable to SCADA operation with RS485 Port consisting of INCOMMING SECTION400 A, 50KA, TPN, MCCB microprocessor baseed(O/C,S/C) release - 1No,SpreaderLinks&ExtendedROHfor-1No,3PhaseDigital Multifunction Meter- 1 No, Digital Voltmeter 0-500V- 3 No, Digital Amperemeter0-1000A -3Nos,CTFormeterResinCastCL- 1000A/5A,15VA - 3 Nos, Phase indication light LED type 220V AC - 1 Set, Control MCB SP 6A ,10KA ABB - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Link - 1 No.OUTGOING SECTION200 A, 50KA, TPN, MCCBmicroprocessor based (O/C,S/C) RELEASE - 3 No, Spreader Links & Extended ROH for MCCB - 3 Nos., 63A TPN MCCB 35KA- 2 Nos. Terminal 63A 235 SupplyofAirCooledDigitalsoftstartersuitablefortheLTmotor offered for operation in AC three Phase 50Hz (+/- 5%), 415V(+/-10%) including line contactors suitable for next standard higher KW rating, Over & Under load protection, short circuit & single phasing protection with frequency meter, Ampere meter, Voltmeter, indicating lamp6Nos,LEDON/OFFtypeandStart/Stoppushbuttonand InstrumentFuses,suitabletoSCADAoperationwithRS485Port rating capacity 75 HP / 55 KW 236 Supply & laying of 1.1KV grade XLPE insulated armured multi strand copperconductorcableof3Cx50sq.mm fromcontrolPanelto respective Motors with lugs etc. (copper conductor should be electrlytic grade copper, purity >99.97% ISI marked asper IS:1554 P-I/ IS :7098 P-I) 237 Supply & Fixing of Powder coated GI Cable Tray 150mmx50mmx1.6mm 238 Earthing with GI earth plate 1200 mm X 1200 mm X 12 mm thick includingaccessories, and providing masonryenclosurewith cover plate having locking arrangement and watering pipe of 3 metre long etc.withcharcoal/cokeandsaltasrequiredaccordingtolatest IS:3043 :2018 239 Supplying and laying 50 mm X 12 mm G.I.strip at 0.50 metre below groundasstripearthelectrode,includingconnection/terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done byoverlappingandwith2setsofbrassnutbolt&springwasher spaced at 50mm) 240 Supply of ABC Dry Powder type Fire Extinguisher 4.5 kg conforming to IS: 15683:2006 241 Supply of CE/UL Certified Surge protector for control panel 242 Supply of Auto Phase reversal unit / Automatic switch with inbuilt the delay & enclosure (Confirms to IEC: 60947-1 & IEC: 60947-6-1) of 400 Amp 243 S& F of all in one solar LED street light fixture with Integrated high efficient Monocrystalline panel with Lithium (LiFePO4) Ferro PhosphatebatterywithBISapprovedmake.luminaireshouldbe secondary optic lenses for better distribution with delivered efficacy of >100 Lumen per watt. Luminaire can be supplied with Hybrid switch along with indicator to understand the source of power( either from solar or AC supply).shall have certificate tested fromMNRE approved Lab.Guaranteefortotalsystemistwoyears.Note:Alltheabove should be integrated and should be 1 system. make: Bajaj/ Philips / Crompton. Compact SolarLED Street Light- 60W/12V/27Ah with GI pole 244 Internal & External electrification of Pump house :- 245 Twin tube light covered LED 20 Watt 246 450 mm dia exhaust fan 247 Providing & Fixing of IK07 IP-66 protected high power LED flood light system with Pressure diecast aluminium housing LM6/ ADC12 material 60 Watt Flood light 248 CompletewiringofPumphouse with1.5 Sqmm& 2.5Sqmm multistarndcopperconductorwire1.1KVwithrequired5A&15A switches, ceiling rose 249 RubbermatsforelectricalpurposeasperIS:5425-1969, plain/chequered (1mX2m) - 19mm thickness 250 INSTRUMENTATIONWORKS AT INTAKE WELL 251 Supply of CE/UL Full Bore Electromagnetic Flow Meter of approved makeoffollowing dia and specifications complete: Media : Water (Raw/ Chlorinated), Pressure:upto1.0 MPa,Process temp:-50degC, Flow/MeterTube:SS304, Electrode:SS AISI 316L /Hastelloy C276/Tantalum,LiningMaterial:Hard Rubber/ Neoprene/Poly-urethane(PU) , Flange : SS /CS, Flange Standard&Rating:ANSI150,Coilhousing:SSAISI304/Carbon Steel/DieCastAluminium, withanticorrosivepaint &provide completelysealed(leakproof)constructionasperrequirement ‘of IEC60529,Accuracy:+0.5%M.V.-velocity0.3to10m/s, Transmitter/signaconvertor Enclosure :DieCast Aluminium, Power Supply : 80-240V AC - 5OHz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart,Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable(size - 350 mm dia at common header) 252 SupplyofCE/ULCertifiedpressuretransmitterCEmarkdwith following technical parametersand Interfacing with PLC panel includingmounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 253 Supply of CE/UL cirtified ofRadar level transmitter CE marked with following technical parametersand Interfacing with PLC panel including mounting arrangement.Output-4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 254 CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with intelligent GSM Based modem unit with CPU and PowerSupplywithanalogandDigitalParameterandfeaturesas specified tostoreandtransmitdataonGSMbackbone,RTU/PLC designedwithlogictotansferdataatmultiplestationsandalso compatible for satellite communication. 255 Control panel with IP 54 Protection, Industrial grade forall equipment and 24V and power supply 256 GSM/GPRS based wirelesscommunicationwith 4G modem for RTU/PLC Capable to transfer and gather data from remotesites to control stations all accessories included with signal enhancer, antenna made for pumping plantwith SIM andrecharge 257 CE & UL Certified 10 HMI touch screen suitable to communication with PLC/RTU for local display & control of process parameters 258 CE/UL Certified Intelligent energy meters 259 Complete cabling for instrumentation works with power cabeling to panel of automation 260 SecuritySurvelliance IP 4.0 MP HD Bullet Guard + AudioCamerawith NVR 2 SATA, 2 TB HDD, HDMI cable, CAT 6 cable etc allrequiredaccessoriesfor pump house, substation and campus. 261 Installation, testing and comissioning of pumping plant & associated allequipmentsasperapproveddrawingshallbedonebybidder includingchequerredplateandpaintingofpumpingplant&main piping-valves. 262 Testing of Pumping Plant & Control Panel & valves etc at Manufacturer Works 263 CLEAR WATER PUMPING PLANT AT MCWR 264 SupplyofVerticaltypeselfwaterlubricatedstatically,dynamically, hydraulically balanced turbine pump capable of discharging at 1450 rpm thefollowingdutyconditionasgivenbelowduetoallcauseswith surfacedischargeheadconfirmingtoIS:1710andasamendedason datewithaccessoriesasperIS5120/1977(Reconfirmed2011)andas amended thereafter to suit the site condition.The Pump Bowl assembly shall be FG: 260 with 2% NiCi with CF8M impeller running at 1450 rpm., head shaft, SS-410 line shaft , Rubber line shaft bearing , C.I. Bearing retainer,Suctionbellmouth,strainer,oiltubeand05mtr/suitable lengthcolumnassembly,withverticalSolidshaft Squirrelcage induction motor copper wounded and die cast copper rotor (IS:126152011/IEC 60034-1) suitable for the above pump continuous rated TEFC IP-55 with Class F insulation, anti rotation locking arrengement for operation in AC, three Phase/50 HZ (±5%), 415V (±10%), running with a speed of pump.CAPACITY:- 5300 LPM / 50 Mtr. HEAD / 100 HP MOTOR (2w+2s) 265 MAIN PIPING AND VALVES :- 266 SupplyofDIDFSingleDoor/MultiDoorNonreturn/refluxvalve conforming to IS:5312/2003(part I & II) PN-1.0 to be fixed after pumps for 90% fast closing & 10% slow closing 250 mm 267 SupplyofDIDFsluicevalvewith Electricallyintegratedactuater (Totally enclosed, weather-proof and dust proof construction with IP- 67(IP-68 for field installation),protectionclasssuitableforinstallationinanypositionwithout lubrication, leakage or other operational difficulty with special grease filled gear box and suitable for manual operation for emergency which willautomaticallydis-engageonrestorationofpowertomotorand with 10 watt single phase space heater and continuous local mechanical position indicator and individually replaceable counter gear assembly and with two torque and four limit switches with S.S. flap and operated with gear driven cams and of rating 250 Volt, 5 Amp, AC/DC, torque switch dial and with TEFC squirrel cage induction) operated with positioning card suitable to SCADAoperation sluice valve having Body : DI GGG 40 / IS 1865 Gr. 400/15, Wedge : DI GGG 40 /IS 1865 Gr. 400/15, Dome : DI GGG 40 / IS 1865 Gr. 400/15, Wedge Nut: Brass / Al. Bronze , Spindle : SS AISI 410 , Seat Rings : LTB IS : 318 Gr. LTB 2,Spindle Nut : LTB IS : 318 Gr. LTB 2 . Valves aresuitable for hydrostatic test pressure of 10Kg./Cm2 for seat and 15Kg./Cm2 for body(PN-1.0)of following sizes :- 268 250 mm dia size at Pump delivery 269 350 mm dia size at common header 270 Supply of DIDFmanually operated sluice valve having body Body : DI GGG 40 / IS 1865 Gr. 400/15, Wedge : DI GGG 40 /IS 1865 Gr. 400/15, Dome : DI GGG 40 / IS 1865 Gr. 400/15, Wedge Nut: Brass / Al. Bronze , Spindle : SS AISI 410 , Seat Rings : LTB IS : 318 Gr. LTB 2,Spindle Nut : LTB IS : 318 Gr. LTB 2 . Valves generally conform to IS:5312.Flanges tobedrilledasperIS:1538Part-IV&VI. Valves aresuitable for hydrostatic test pressure of 10Kg./Cm2 for seat and 15Kg./Cm2 for body(PN-1.0 Rating) Sluice Valve of 350 mm dia size at By-pass 271 Supply and fabrication of main piping of following sizes350 x 250 x 350 mm MS D/F Tee (10 mm thickness) -4 No250 mm MS D/F Pipe 0.50 mt. (10 mm thickness) - 4 No 250 mm MS D/F Pipe 1.00 mt.(10 mm thickness) - 4 No 350 mm MS D/F Pipe 1.00 mt.(10 mm thickness) - 4 No 350 mm MS D/F Pipe 2.00 mt. (10 mm thickness) -2 No 350 mm MS D/F (10 mm thickness) Bend 90o - 2 No 350 mm Blind Flange - 1 NoNecessary G.I. Nut Bolt’s & Rubber Packing - 1 Lot 272 SupplyofD.I./D.F.DismantlingJointsisavariablelengthDouble Flanged Short Piece constituted by a flange / Spigot Tailpiece inserted intotheotherTailpiecewhichallowsthedistancebetweenthetwo flangestobevariedwithincertainlimitsthusprovidingavariable distance piece between two fixed flange end devices like Pumps and Valves.TheDismantlingJointtobesuppliedcompletewithSealing RubberGasketsofEPDMquality(IS:5382/1985Type-4),CastIron Follower Glands andMildSteel (ZincCoated)NutBoltsof Following size 273 Dismantling joint 200 mm dia size at pump delivery 274 Dismantling joint 350 mm dia size at common header 275 3 Ton capacity hand operated over head Travelling (HOT) crane suitable for a span upto 6 Mtrs, and travel length upto 10 Mtrs. with clear lift upto 6 M including gear type chain pulley block and geared Travelling trolley complete with all accessories including girder. 276 MOTOR CONTROL CENTER (MCC) PANEL :-Single front, Indoor & floor mounted,cubical type Panel factory fabricated(2mmthickforsructure,1.6mmthickfordoor,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coated dustandverminproofIP-54/IS:2147,consideredEarthBus-Bar-Copper Strip compitable to SCADA operation with RS485 Port consisting of INCOMMING SECTION400 A, 50KA, TPN, MCCBmicroprocessor baseed(O/C,S/C) release - 1 No,SpreaderLinks&ExtendedROHfor-1No,3PhaseDigital MultifunctionMeter-1No,DigitalVoltmeter0-500V-1No,Digital Amperemeter0-400A -3Nos,CTFormeterResinCastCL- 200A/5A,15VA - 3 Nos, Phase indication light LED type 220V AC - 1 Set, ControlMCBSP6A,10KA-3Nos,CTShortingTerminal-4Nos, Neutral Link - 1 No.OUTGOING SECTION250 A, 50KA, TPN, MCCBmicroprocessor based (O/C,S/C) RELEASE - 4 No, Spreader Links & Extended ROH for MCCB - 4 Nos., 63A TPN MCCB 35KA- 2 Nos. Terminal 63A 277 SupplyofAirCooledDigitalsoftstartersuitablefortheLTmotor offeredforoperationinACthreePhase50Hz(+/-5%), 415V(+/-10%) including line contactors suitable for next standard higher KW rating, Over & Under load protection, short circuit & single phasing protection with frequency meter, Ammeter, Voltmeter, indicating lamp 6Nos, LED ON/OFFtypeandStart/StoppushbuttonandInstrumentFuses, suitable to SCADA operation with RS485 Port rating capacity 100 HP / 75 KW 278 Supply & laying of 1.1KV grade XLPE insulatedarmured multi strand copperconductorcableof3Cx95sq.mm fromcontrolPanelto respective Motors with lugs etc. (copper conductor should be electrlytic grade coppe, purity >99.97 % ISI marked as per IS:1554 P-I / IS:7098 P- I) 279 Supply & Fixing of Powder coated GI Cable Tray 150mmx50mmx1.6mm 280 EarthingwithGIearthplate1200mmX1200mmX12mmthick includingaccessories,andprovidingmasonryenclosurewithcover plate having locking arrangement and watering pipe of 3 metre long etc. with charcoal/ coke and salt as required according to latest IS:3043:2018 281 Supplyingandlaying50mmX12mmG.I.stripat0.50metrebelow ground as strip earth electrode, including connection/ terminating with nut,bolt,spring,washeretc.asrequired.(Jointingshallbedone by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 282 Supply of ABC Dry Powder type Fire Extinguisher 4.5 kg conforming to IS: 15683:2006 283 Internal & External electrification of Pump house :- 284 Twin tube light covered LED 20 Watt 285 450 mm dia exhaust fan 286 Providing & Fixing of IK07 IP-66 protected high power LED flood light system with Pressure diecast aluminium housing LM6/ ADC12 material 60 Watt Flood light 287 Complete wiring of Pump house with 1.5 Sqmm & 2.5 Sqmm multistarnd copper conductor wire 1.1 KV with required 5A & 15A switches, ceiling rose 288 Supply of CE/UL Certified Surge protector for control panel 289 RubbermatsforelectricalpurposeasperIS:5425-1969, plain/chequered (1mX2m) - 19mm thickness 290 INSTRUMENTATION WORKS 291 SupplyofCE/ULFullBoreElectromagneticFlowMeterofapproved makeoffollowingdiaandspecificationscomplete: Media: Water ( Chlorinated) , Pressure : up to 1.0MPa, Process temp:-50degC, Flow/MeterTube:SS304, Electrode:SSAISI 316L /Hastelloy C276/Tantalum,LiningMaterial:HardRubber/ Neoprene/Poly-urethane(PU) , Flange : SS /CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Cast Aluminium, withanticorrosivepaint&providecompletely sealed (leakproof) construction as per requirement ‘of IEC 60529, Accuracy:+0.5%M.V.-velocity0.3to10m/s,Transmitter/signa convertorEnclosure: Die CastAluminium,Power Supply : 80-240V AC - 5OHz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart,Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parameters and totalizer value during power failure, Protection category-IP68forsensor(flowtube)andIP67fortransmitter/ convertor, including Surge Arrester, cable, of of following sizes :- 292 350 mm dia. Size at common header of pumping plant 293 350 mm dia. Size at OHT outlet of zone-1 294 350 mm dia. Size at OHT outlet of zone-2 295 450 mm dia. Size at OHT outlet of zone-3 296 200 mm dia. Size at OHT outlet of zone-4 297 Supply of Electrically Motor operated actuator with positioning card and bracketforsluicevalvesuitableforSCADAoperationwithlimit switches, auto de clutch for manual operation in emergency etcas per relevant IS suitable forOHT outlet of following sizes 298 350 mm dia. Size at OHT outlet of zone-1 299 350 mm dia. Size at OHT outlet of zone-2 300 450 mm dia. Size at OHT outlet of zone-3 301 200 mm dia. Size at OHT outlet of zone-4 302 SupplyofD.I./D.F.DismantlingJointsisavariablelengthDouble Flanged Short Piece constituted by a flange / Spigot Tailpiece inserted intotheotherTailpiecewhichallowsthedistancebetweenthetwo flangestobevariedwithincertainlimitsthusprovidingavariable distance piece between two fixed flange end devices like Pumps and Valves.TheDismantlingJointtobesuppliedcompletewithSealing RubberGasketsofEPDMquality(IS:5382/1985Type-4),CastIron Follower Glands andMildSteel (ZincCoated)NutBoltsof Following size 303 Dismantling joint 350 mm dia size at OHT outlet of zone-1 304 Dismantling joint 350 mm dia size OHT outlet of zone-2 305 Dismantling joint 450 mm dia size at OHT outlet of zone-3 306 Dismantling joint 200 mm dia size at OHT outlet of zone-4 307 Supply of CE/UL Certified pressure transmitter CE markd with following technical parametersand Interfacing with PLC panel includingmounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 308 Supply of CE/UL cirtified ofRadarlevel transmitter CE marked with following technical parameters and Interfacing with PLC panel including mounting arrangement.Output-4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 309 CE & UL Certified PLC/ RTU with redundent CPU & power supply in IP 54 enclosure suitable to communicate with GSMBasedmodemwith redundentCPU andPower Supply with analog and Digital Parameter and features as specified for each ZPSto store and transmit data on GSM backbone, RTU/PLC designed with logic to tansferdataatmultiplestationsandalsocompatibleforsatellite communication for CWR. 310 Control panel with IP 54 Protection , Industrial grade for all equipment and 24V and power supply 311 GSM/GPRS based wireless communication with 4G modem for RTU/PLCCapabletotransferandgatherdatafromremotesitesto control stations all accessories included with signal enhancer, antenna made for pumping plantwith SIM and recharge for CWR & OHT 312 CE & UL Certified 10 HMI touch screen suitable to communication with PLC/RTU for local display & control of process parameters. 313 CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with intelligentGSMBasedmodemunit with CPU andPower Supply with analog and Digital Parameter and features as specifiedto store and transmit data on GSM backbone, RTU/PLC designed with logic to tansferdataatmultiplestationsandalsocompatibleforsatellite communication for OHT 314 Control panel with IP 54 Protection , Industrial grade for all equipment and 24V and power supply 315 GSM/GPRS based wireless communication with 4G modem for RTU/PLCCapabletotransferandgatherdatafromremotesitesto control stations all accessories included with signal enhancer, antenna made for pumping plantwith SIM and recharge for OHT 316 CE/UL Certified Intelligent energy meters 317 Complete cabling of instrumentation equipments with power supply of panels for CWR & OHT 318 SecuritySurvelliance IP 4.0 MP HD Bullet Guard + AudioCamerawith NVR 2 SATA, 2 TB HDD, HDMI cable, CAT 6 cable etc allrequiredaccessoriesfor pump house, substation and campus. 319 Installation, testing and comissioning of pumping plant & associated all equipments as per approved drawing shall be done by bidder including chequerred plate and painting of pumping plant & main piping-valves. 320 Testing of Pumping Plant & Control Panel & valves etc at Manufacturer Works 321 11/0.44KV SUB STATION AT INTAKE WELL 322 Supply of star rated Copper wound distribution Transformer ( All the distributiontransformermustbestarratedaspernotificationof (BEE)ministryofpower,GoverenmentofIndia)offollowingrating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11, ONAN Cooled & as per BEE star level- 2 & BIS approved as per IS 2026-1977 & losses as defined as per IS 1180 part (I) 2014 including standard accessories like conservator, silica gel breather,Bucholz relay, radiator, fins, HT cablebox<cableboxes,Off-LTC(+7.5%to-15%@2.5%) temperature rise of 40 degree C in oil / 45 degree C in winding , ISI marked drain valve, Dial type Temperature gauge, OTI & WTI, marshallingbox,firstfillingoftransformeroilasperIS:335-1953, Epoxy based paint.Rating capacity - 200 KVA (1w+1s) 323 Supply of SCADA compatible with RS 485 port , 11KV, 800 A, 25kA / 1 Sec, VCB Indoor type panel HT board, free standing motor operated & withdrawal type fabricated from 2 mm thick CRCA sheet steelWith Copper Bus bar, Ammeter,Voltmeter,PFMeter,KWHMeter,MDIMeter,Selector Switches as required, CRT-CT of required ratio (15VA ; Cl-1.0 / 0.5 ) PT (11 KV /110V/√3) , Fuses , IP42 Protection, 10 / 12-window Annunciation Panel , AC/ DC Control voltage 24/48/ 110/230V , LED Indication lamps, S/C, O/C & E/F Protection (IDMT) Relays Alarm & trip contacts for Transformerprotection(Highoiltemperature,Buchholzprotection, highwindingtemperature,powerpack2x12V,etccompleteinall respect ready to use(RTU),OEM Must have BIS certificate incuding 1no incoming & 2 no outgoing VCB. 324 Singlefront,Indoor&floormounted,cubicaltypeLTPanelfactory fabricated(2mmthickforsructure,1.6mmthickfordoor,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coated dustandverminproofIP-54/IS:2147, consideredEarth Bus-Bar-Copper Strip compitable to SCADA operation with RS485 Port consisting of INCOMMING SECTION400 A, 50KA, TPN, MCCB microprocessor baseed(O/C,S/C) release - 3 No, 3 Phase Digital Multifunction Meter- 1 No, Digital Voltmeter 0- 500V- 1 No, Digital Ampere meter 0-1000 A- 3 Nos, CT For meter Resin Cast CL-1000A/5A,15VA - 3 Nos, Phase indication light LED type 220V AC - 1 Set, Control MCB SP 6A ,10KA ABB - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Link - 1 No.OUTGOING SECTION400A,50KA,TPN,ACB, EDO microprocessor based(O/C,S/C) RELEASE - 1 No, 63A TPN MCCB 32KA- 2 Nos. Terminal 63A. 325 Supply and laying of 11/12KV grade XLPE insulated H.T. armoured cable as per IS:7098 / II/85,H4- Grade aluminium conductor of purity >99.6 % & as per IS:1554 P-I / IS :7098 P - (I)from UPPCLmetering panel to H.T. Switch gear panel and panel to transformers 120 Sq.mm. size 326 Supply of H.T. Cable end termination heat shrinkable type indoor joint kit 120 sq.mm. 327 SupplyofH.T.Cableendterminationheatshrinkabletypeoutdoor joint kit 120 sq.mm. 328 Supply & laying of L.T. XLPE insulatedarmoured aluminium conductor cableof1.1KVgradeMaterial:-H4-Gradealuminium conductorofpurity>99.6%&asperIS:1554P-I/IS:7098P- (I),conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999.From transformer to Main LT panel and main LT panel to MCC panel of 3.5C x 300 Sq.mm. 329 Earthing with copper earth plate 1200 mm X 1200 mm X 12 mm thick includingaccessories,andprovidingmasonryenclosurewith cover plate having locking arrangement and watering pipe of 3 metre long etc.withcharcoal/cokeandsaltasrequiredaccordingtolatest IS:3043 330 Supplying and laying 50 mm X 12 mm G.I.strip at 0.50 metre below groundasstripearthelectrode,includingconnection/terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done byoverlappingandwith2setsofbrassnutbolt&springwasher spaced at 50mm) 331 Supply and Fixing of fire extinguisher of 5 Kg. capacity conforming to IS: 15683:2006 332 RubbermatsforelectricalpurposeasperIS:5425-1969, plain/chequered (1mX2m) - 19mm thickness 333 NOC from electrical safety Dept. Govt. of UP 334 Fancing of substation in 2mtr height made from MS iron Jali & MS flat, angleironandgroutinginpropermannerasperrelevantIScode including supply and laying of stone grit. 335 Internal & External electrification of HT & LT panel room :- 336 Twin tube light covered LED 20 Watt 337 450 mm dia exhaust fan 338 Providing & Fixing of IK07 IP-66 protected high power LED flood light system with Pressure diecast aluminium housing LM6/ ADC12 material 60 Watt Flood light 339 CompletewiringofHTandLTroom with1.5Sqmm&2.5Sqmm multistarndcopperconductorwire1.1KVwithrequired5A&15A switches, ceiling rose 340 S& F of all in one solar LED street light fixture with Integrated high efficient Monocrystalline panel with Lithium (LiFePO4) Ferro PhosphatebatterywithBISapprovedmake.luminaireshouldbe secondary optic lenses for better distribution with delivered efficacy of >100 Lumen per watt. Luminaire can be supplied with Hybrid switch along with indicator to understand the source of power( either from solar or AC supply).shall have certificate tested fromMNRE approved Lab.Guaranteefortotalsystemistwoyears.Note:Alltheabove should be integrated and should be 1 system. make: Bajaj/ Philips / Crompton. CompactSolarLEDStreetLight- 60W/12V/27Ah with GI pole 341 Supplyofmicroprocessorbasedthreephasesensingpowerfactor correction relay panel , IEC / EN 61000-6- (2&4) having 3 CT sensing, sensitivity up to 50 milli amp secondary current , self analysing auto c/k setting according to targeted power factor setting, the relay shall have digit display unit for display of real power factor, targeted power factor,lag/leadcapacitorswitchingstatus,alarmoutputforunder current, over current, insufficient compensation, communication interface with RS 485, indication of switching on units, auto/manual status, and shall have over load protection, no volt release , having multi parameter like KW, KVA, KVAR rating capacity of 100 KVAR 342 SITC of 01 No. DG Set of Capacity 180 KVA 415+ volt with AMF control Panel cabling,copper earthing etc. complete in all respect.( As per Lataest CPCB- IV Emission Norm ) 343 Installation, testing and commissioning of 11 KV /.44 KV substations includingH.T.panelandL.T.panelincludingchequeredplates,all labour T&P complete in all respect. 344 Testing of DG., Transformer, HT and LT Panel etc at Manufacturer Works 345 11/0.44KV SUB STATION AT MCWR 346 SupplyofstarratedCopperwounddistributionTransformer(Allthe distribution transformer must be star rated as per notification of (BEE) ministry of power, Goverenment of India) of following rating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11, ONAN Cooled & as per BEE star level- 2 & BIS approved as per IS 2026-1977 & losses as defined as per IS 1180 part (I) 2014 including standard accessories like conservator, silica gel breather,Bucholz relay, radiator, fins, HT cable box & LT cable boxes, Off -LTC (+7.5% to - 15% @ 2.5%) temperature rise of 40 degree C inoil/45degreeCinwinding,ISImarkeddrainvalve,Dialtype Temperature gauge, OTI & WTI, marshalling box, first filling of transformer oil as per IS :335-1953, Epoxy based paint.Rating capacity - 400 KVA (1w+1s) 347 Supply of SCADA Compatible with RS 485 port 11KV,800 A, 25kA / 1 Sec, VCBIndoortypepanelHTboard,freestandingmotoroperated& withdrawaltypefabricatedfrom2mmthickCRCAsheetsteel,With copper busbar, Ammeter, Voltmeter, PF Meter, KWH Meter, MDI Meter, Selector Switches as required, CRT-CT of required ratio (15VA ; Cl-1.0 / 0.5 ) PT (11 KV /110V/√3) , Fuses , IP42 Protection, 10 / 12-window Annunciation Panel, AC/ DC Control voltage 24/48/ 110/230V , LED Indication lamps , S/C, O/C & E/F Protection (IDMT) Relays Alarm & trip contacts for Transformer protection(High oil temperature, Buchholz protection, high winding temperature, power pack 2 x 12 V,etc complete in all respect ready to use(RTU),OEM Must have BIS certificate incuding 1no incoming & 2 no outgoing VCB 348 Singlefront,Indoor&floormounted,cubicaltypeLTPanelfactory fabricated (2 mm thick for sructure, 1.6mm thick for door,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coateddust and vermin proof IP-54 /IS:2147, considered Earth Bus-Bar-Copper Strip compitable to SCADA operation with RS485 Port consisting of INCOMMING SECTION800 A, 50KA, TPN, ACB, EDOmicroprocessor baseed(O/C,S/C) release-2No SpreaderLinks&ExtendedROH -2No,3PhaseDigital MultifunctionMeter -1No,DigitalVoltmeter0-500V -1No,Digital Ammeter 0-400A -1No, CT For meter Resin Cast CL-1400A/5A,15VA - 3 Nos, Phase indication light LED type 220V AC - 1 Set, Control MCB SP 6A,10KA ABB - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Link - 1 No.OUTGOING SECTION400 A,50KA,TPN, MCCB microprocessor based (O/C,S/C) RELEASE-2 No, 200 A,50KA,TPN, MCCB microprocessor based (O/C,S/C) RELEASE-2No, spreader Links & Extended ROH for MCCB - 4 Nos., 63A TPN MCCB 32KA- 2 Nos. Terminal 63A 349 Supplyandlayingof11/12KVgradeXLPEinsulatedH.T. armouerd cableasper IS:7098 / II/85,H4- Grade aluminium conductor of purity >99.6 % & as perIS:1554P-I/IS:7098P-(I)fromUPPCL meteringpaneltoH.T. Switch gear panel and panel to transformers 120 Sq.mm. size 350 Supply of H.T. Cable end termination heat shrinkable type indoor joint kit 120 sq.mm. 351 Supply of H.T. Cable end termination heat shrinkable type outdoor joint kit 120 sq.mm. 352 Supply & laying of L.T. XLPE insulatedarmoured aluminiumconductor cableof1.1KVgradeMaterial:-H4-Gradealuminiumconductorof purity >99.6 % & as per IS:1554 P-I / IS :7098 P-(I),conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999.From transformer to Main LT panel of 3.5C x 300 Sq.mm. (in 2 run for each transformer) 353 Supply & laying of L.T.XLPE insulatedarmoured aluminiumconductor cableof1.1KVgradeMaterial:-H4-Gradealuminiumconductorof purity >99.6 % & as per IS:1554 P-I / IS :7098 P-(I),conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999.From Main LT panel to MCC Panel at WTP of 3.5C x 150 Sq.mm. 354 Supply & laying of L.T.XLPE insulatedarmoured aluminiumconductor cableof1.1KVgradeMaterial:-H4-Gradealuminiumconductorof purity >99.6 % & as per IS:1554 P-I / IS :7098 P-(I),conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999.From Main LT panel to MCC Panel at MCWR of 3.5C x 400 Sq.mm. 355 EarthingwithGIearthplate1200mmX1200mmX12mmthick includingaccessories,andprovidingmasonryenclosurewithcover plate having locking arrangement and watering pipe of 3 metre long etc. with charcoal/ coke and salt as required according to latest IS:3043:2018 356 Supplyingandlaying50mmX12mmG.I. stripat0.50metrebelow ground as strip earth electrode, including connection/ terminating with nut,bolt,spring,washeretc.asrequired.(Jointingshallbedoneby overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 357 Supply and Fixing of fire extinguisher of 5 Kg. capacity conforming to IS: 15683:2006 358 Rubber mats for electrical purpose as per IS:5425-1969, plain/chequered (1mX2m) - 19mm thickness 359 NOC from electrical safety Dept. Govt. of UP 360 Fancing of substation in 2.5mtr height made from MS iron Jali & MS flat, angleironandgroutinginpropermannerasperrelevantIScode including supply and laying of stone grit. 361 Internal & External electrification of Pump house :- 362 Twin tube light covered LED 20 Watt 363 450 mm dia exhaust fan 364 Providing & Fixing of IK07 IP-66 protected high power LED flood light system with Pressure diecast aluminium housing LM6/ ADC12 material 60 Watt Flood light 365 CompletewiringofHTandLTroom with1.5Sqmm&2.5Sqmm multistarndcopperconductorwire1.1KVwithrequired5A&15A switches, ceiling rose 366 Supply of Auto Phase reversal unit / Automatic switch with inbuilt the delay&enclosure(Confirms to IEC:60947-1&IEC: 60947-6-1)of 630 Amp 367 Supplyofmicroprocessorbasedthreephasesensing auto powerfactor correction relay panel , IEC / EN 61000-6- (2&4) having 3 CT sensing, sensitivity up to 50 milli amp secondary current , self analysing auto c/k setting according to targeted power factor setting, the relay shall have digit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current,insufficientcompensation,communicationinterfacewithRS 485, indication of switching on units, auto/manual status, and shall have over load protection, no volt release , having multi parameter like KW, KVA, KVAR rating capacity of 200 KVAR 368 SITC of 01 No. DG Set of Capacity 380 KVA 415+ volt with AMF control Panel cabling, earthing etc. complete in all respect. ( As per Lataest CPCB- IV Emission Norm ) 369 Installation,testingandcommissioningof11KV/.44KVsubstations including H.T. panel and L.T. panel including chequered plates, all labour T&P complete in all respect. 370 Testing of D.G, Transformer, HT and LT Panel etc at Manufacturer Works 371 Automation of DMA 372 Flow Control Valve 373 Supplying, installing ,commissioning & testing of Flow Control Valvefor inlet with flow measuring, flow controlling, pressure monitoringandweb based with cable PLC etc Complete.Pattern Hydraulically operated self actuated flow & level control valve (either with float or altitude pilot) with downstream orifice having Ductile Iron valve body, Y - Pattern, Double Chamber, unitized actuator, Fusion bonded epoxy coating, copper control tubing with Latching Solenoid & Pilot operated as per design, additional speed control feature, drip tight sealing, In-line serviceable, internals stainless steel & protected diaphragm suitable for drinking water. 374 For Zone -1 375 300 mm ( for OHT Inlet) 376 250 mm ( DMA-1) 377 250 mm ( DMA-2) 378 250 mm ( DMA-3) 379 For Zone -2 380 300 mm ( for OHT Inlet) 381 200 mm ( DMA-1) 382 250 mm ( DMA-2) 383 250 mm ( DMA-3) 384 For Zone -3 385 450 mm ( for OHT Inlet) 386 300 mm ( DMA-1) 387 400 mm ( DMA-2) 388 300 mm ( DMA-3) 389 For Zone -4 390 100 mm ( for OHT Inlet) 391 200 mm ( DMA-1) 392 IsolationValve 393 Supplying, installing ,commissioning & testing of DI Isolationvalve with electric acuator for isolation of DMA flow controling with cable PLC etc Complete. 394 For Zone -1 395 250 mm ( DMA-1) 396 250 mm ( DMA-2) 397 250 mm ( DMA-3) 398 For Zone -2 399 200 mm ( DMA-1) 400 250 mm ( DMA-2) 401 250 mm ( DMA-3) 402 For Zone -3 403 300 mm ( DMA-1) 404 400 mm ( DMA-2) 405 300 mm ( DMA-3) 406 For Zone -4 407 200 mm ( DMA-1) 408 Pressure Transmitter 409 Supplying, installing ,commissioning & testing of CE/UL Certified Pressure Transmitterfor pressure monitoring web based with cable PLC etc Complete for all 10 DMA,s of All 4 Zones 410 Electromagnetic Flow Meter 411 Supplying, installing ,commissioning & testing of CE/UL Certified Electromagnetic Flow Meterfor Flow monitoringweb based with cable PLC etc Complete 412 For Zone -1 413 250 mm ( DMA-1) 414 250 mm ( DMA-2) 415 250 mm ( DMA-3) 416 For Zone -2 417 200 mm ( DMA-1) 418 250 mm ( DMA-2) 419 250 mm ( DMA-3) 420 For Zone -3 421 300 mm ( DMA-1) 422 400 mm ( DMA-2) 423 300 mm ( DMA-3) 424 For Zone -4 425 200 mm ( DMA-1) 426 Residual Chlorine Analyser 427 SITC of Chlorine Analyser with MODBUS RTU having Following specification - (a) FRC senser range 0-5 ppm (b) Analyser with RS 485 O/P suitable to OHT distribution line and compatible with SCADA system toofor all 10 DMA,s of All 4 Zones 428 Chlorine Dozer For DMA 429 SITC of SCADA Compatible Chlorination Systemfor all 10 DMA,s of All 4 Zones 430 SCADA For DMA 431 CE & UL Certified PLC/RTUin IP 54 enclosure suitable to Communicate with GSM based modem unit with CPU & Powersupply with annlog & digital parameter & featuers as specified, for each DMA to store and transmit dataon GSM backbone, RTU/PLC desgined with logic to transfer data at multiple stations with control panel as specified intender technical specifications. 432 G.S.M./G.P.R.S. based wireless communication with 4G modem for RTU/PLC Capable to transfer & gather data from remote sites to control stations all accessories include with signal enhancer antenna made for pumping plant internetcharges as specified in tender technical specification . 433 Intelligent energy meters 434 Control Panel with IP 54 Protection, Industrial Grade for all equipment. (Separate for control (24 V) and power equipments.) upto 3 pumps. 435 CE/ UL Certified 10 HMI touch screen suitable to communication with PLC/RTU for local display & control of process parameters. 436 CE/UL Certified 1 KVA UPS with Batteries for data backup. 437 CE/UL Certified 10 KVA UPS with Batteries for valve operation of each OHT . 438 Cabling 439 Complete Cabling for Intake well including all power & control cable of all equipments at ZPS and OHT. 440 SecuritySurvelliance IP 4.0 MP HD Bullet Guard + AudioCamerawith NVR 2 SATA, 2 TB HDD, HDMI cable, CAT 6 cable etc allrequiredaccessories . 441 MASTER CONTROL STATION (MCS) AT WTP 442 CE/UL & BIS Certified industrial grade LED MONITOR with latestconfiguration as per specification 65 443 Video call media player of same OEM 444 Core i7 10th gen Desktop/ laptop with 32 GB RAM and 256 GB SSD + 1TB HDD 445 CE/UL Certified 5 KVA UPS with Batteries required for mentioned work wih 01 hrs backup 446 Full Development version of TAGS SCADA software with costomization of software for MCS for unlimited digital and analog Input / output features as per requirements 447 CE/ULcertifiedmastercontrolroomPLCwithredundantCPU&power supply at MCS in IP-54 enclosure as per site requirement and specification required to complete in all respect 448 CE/UL certified Field gateway agent for transfering data forMCS/control room 449 GSM/GPRSbasedwireless/Broadband/equivelentcommunicationsystem for PLC Capable to transfer and receive data & gather data from remote sitestocontrolstationsallaccessoriesincludedwithsignalenhancer,antenna along with running expences 450 CE/UL certified Firewall for network protection 451 CE/UL Certified Surge protector for Ethernet communication protection 452 CE/UL Certified industrial grade Ethernet switch 453 Mobile app facility system architecture (industries internet based & viewed through mobile apps for increasedblocal & remote visibility) 454 Canon/HP or equivalent Laser Printer 1018 or equivalent. 455 Hp or equivalent multifunctioning Laser Printer with scanner 456 BEE : 5 Star rating 1.5 Ton capacity air conditioner with voltage satbilizer 457 Office furniture ( office table - 2 No, revolving chair- 2No, Office chair-3 No, Godrej almirah - 1No) 458 SecuritySurvelliance IP 4.0 MP HD Bullet Guard + AudioCamerawith NVR 2 SATA, 2 TB HDD, HDMI cable, CAT 6 cable etc allrequiredaccessories. 459 Installation, Commissioning and testing of all above equipments for MCS with all power cables 460 TRAIL & RUN FOR 3 MONTHS WITHOUT ELECTRICITY CHARGES
Contract Date : Ref. Documents   |   Contract Value : Ref. Documents
BRR : 7839569 Tender For External Electrification Work And Fire Fighting Works For Building No-10 (Plot No-13), Sector-28, Yea. Wc-E M-02 - 11kV Ring mains Unit (OUTDOOR TYPE) 3 Supplying,Installation, Shifting, Testing & Commissioning of11kV CT2T2 outdoor type Ring Mains Unitmade of galvanised iron, 3.0 mm thick CRCA steel sheet enclosed mounted on hot deep Galvanized , ISMC channel, IP 54 Protected & IP23D tested, proper ventilated and thermal class K10, with interlocked arrangement, with proper shade of paint and arcing withstand test of 20 kA for 1 sec. consisting of following as per specification complete as required: 4 3 way Ring main Unit (RMU) FBX- C/12-21/ CT2T2 consisting of 1No 630amp load break switchs and Two no 630 amp tee-off with SF6 circuit brakeras per specification with following : 5 Incoming – 1No. incommer each consisting offollowing 6 Machnical ON/OFF/EARTH indication. 7 Earthing switch 8 Machnical ON/OFF/EARTH indication. 9 Cable testing facility without opening the cable comparthent and without connecting the cable terminations. 10 Set of ON/OFF/EARTH semaphore indicating . 11 Live cable Indicating LEDs energized thru capacitive voltage dividers. 12 Right angle boots (Push on type) 13 Suitable space for termination of 1 No. 3 C x 185 sq.mm XLPE cable. 14 800A CU Main horizontal busbars (Inside Tank)Bus bar. 15 Outgoing Feeder 2 No. each consisting of following for 630kVA Transformer : 16 630 Amps manually operated fixed type SF6 Gas Insulated Circuit Breaker and earthing switch with full making capacity at 50 deg.C ambient and 100% humidity. 17 Earthing switch ,,aux contact for switch, 18 Anti reflex operating handle 19 Set of ON/OFF/EARTH semaphore indicating . 20 230Volt Shunt Trip coil for external tripping 21 Three over current and earth fault IDMT Microprocessor base self poweredRelay with instantaneous high set element. 22 8 Window alarm annunciators panel with hooter, push buttons, aux. Contactors etc as required as per specification. 23 Digital Ameter in built selector switch with 3No. CTS 24 Digital Voltmeter in built selector switch with protection fuse 25 Right angle boots (Push on type) 26 voltage presence indicator,Emergency trip Push Button,Aux contacts for breaker, relay trip coil, shunt trip coil,SELF-POWERED RELAY for 50/51/50N/51N,CURRENT TRANSFORMER FOR PROTECTION BUSHING TERMINALS, FAULT PASSAGE INDICATOR, BATTERY,BATTERY CHARGER,TRIVECTOR METER,PHASE INDICATING LEDs,HERMOSTAT,SPACE PANEL HEATER,AUXILLARY TRANSFORMER,MASTER TRIP RELY,TRIP CKT SUPERVISION RELAY,DOOR LIMIT SWITCH,VOLTAGE MONITORINE RELAY, 8 windoe annauncitor, Hooter etc complete as required 27 11KV H.T. Panel(IOCG ) 28 Supply, Installation, Testing and Commissioning of 11KV Indoor Floor mounted, Metal Clad 11 KV, VCB Panel with alu-zinc / GI enclosure with 4 Nos VCBs, totally enclosed & Fully interlocked horizontal drawout, vertical / horizontal isolation type breaker, dust and vermin proof, free standing, having capacities as mentioned below, single break, trip free mechanism, motorised charged and auto-cum-manual closing breaker suitable for use on 11 KV, 3 Phase, 50 Hz A.C supply with short circuit fault level of 500MVA, complete with self contained, fully interlocked , rack in rack out mechanism, air insulated but encapsulated copper bus bars of 800 A capacity, breaker featured with mechanical ON/OFF indicator with hand trip device, spring release coil, shunt trip coil and auxiilary switch of 4 NO + 4 NC and equipped with following switch gears and accessories etc. andsuitable for connecting 3 core 300 Sq.mm XLPE 11 KV cable heat shrinkeable end termination (Cable entry from Bottom ) etc as required. 29 Incomer-1 No. VCB Panels each having the following 30 (a) 1 No. 630A, 11KV, 3 phase, 50 Hz Vacuum Circuit Breaker 31 (b)1 No 3 phase 11 KV/110 Volts PT, class 0.5 accuracy and 100 VA burden with 1 No Voltmeter (0-15 KV), Digital type, selector switch for voltmeter and protection fuses for HT metering upto 12 KV on incomer 32 (c)1 set of dual core 3 CTs 200/5+5A of 15 VA burden and accuracy class 0.5 for metering and class 5P10 for protection 33 (d ) 1 No – multi function meter suitable for operation on 110V a.c supply with RS-485 interface for integration to BMS 34 (e ) 1 No - Digital Tri Vector Meter (Trivector meter shall have communication features for monitoring by BMS) 35 (f) 1 No. Microprocessor based numerical relay for Over current and Earth fault protection 36 (g) 1 set of phase indicating lamps with HRC fuses 37 (h) 1 set of indicating lamps to indicate OPEN, CLOSE, TRIP, SPRING CHARGED, TRIP CIRCUIT HEALTHY 38 (i)6300Amps copper busbar-1 set (common) 39 (j)Test terminal block 40 (k)Trip/Neutral/close switch 41 (l) 1 set of copper bus bar for earthing (common) 42 (m) 1 set of master trip relay & trip circuit healthy supervision relay. 43 (n) Provision for padlocking the incomer VCBs in OFF position. 44 11KV H.T. Panel incomer cum outgoing Panel) as above & as per SLD 45 COMPACT SUBSTATION-1000KVA 46 Supplying, assembling, erecting, connecting, testing and commissioning of 11 KV Compact Secondary Sub Station outdoor type designed for natural cooling having type tested equipment comprising distribution transformers, SF6 insulated compact switchgear having metal enclosed robotically sealed/welded stainless steel tank , low voltage switchboard, interconnection between HT switchgear & Transformer using single core cables and Transformer to LT switchgear using Al bus bars/Cables factory built / ready for connection type,otherassociated equipment etc including necessaryfoundation and earth work etc. without oil pits complete as required conforming to detailed specification laid down in the tender documents. The enclosure shall have modular construction using 2mm thick CRCA and 4 mm thick got dipped CRCA sheets for base and shall be painted with polyurethane paint from the exterior.The enclosure for LT switchgear & HT switchgear shall be provided with IP54ingress protection. The transformer compartment will have IP34 ingress protection. Note- HT & LT Switchgear should besame make. 47 The transformer used shall be specially designed for low losses (As per IS:-1180 level-01) and shall be hermetically sealed oil immersed& with corrugated tank, oil level indicator, hermetic protection realy, pressure relief device, gas filling valve, oil temprature indicator, multi function relay (DGPT Device) etc. as required Complete in all respect.The earthing shall be suitablefor 18.3KA fault current.The varoius combinations of CSS shall be as per details below including necessaryfoundation and earth work etc 48 HT Switchgear Section 49 11KV 3 Way RMU( CCT2) type Compact switchgear unit having 2 No. Isolater load break switches and1 No SF 6 circuit breaker enclosed in robotically laser welded non-extensible type stainless steelSF6 enclosure with Self powered relay (IDMTL O/C + E/F ) as HT switchgear as per the requirement detailed in the tender documents/SLD. 50 Copper bus bars of 800 A capacity for HT 11 KV network. 51 Transformer Section 52 11KV/415V,1000KVA, hermetically sealed oil immersed Transformer suitable for CSS as per detailed specifications, with Automatic on load tap changer & RTCC .Remote tap changer circuit (RTCC) panel with all associated accessories as per schedules and specifications.Taps on HV for HV variation : +5 to - 15 % in the steps of 1.25 with AVR. 53 LV Switchgear Section 54 LT section comprising the following & as shown in the drawing: 55 1600Amps 415V, 4P, 50Hz, 50KA Manual operated drawout type Air Circuit Breaker (ACB) with overload and short circuit Protection. 56 RELAYs, METERING INDICATOR & CTs 57 On/Off Indication lamps with 6A control MCB as per fault requirement 58 R,Y,B phase Indication lamps with Control MCB as per fault requirement. 59 One Set of 5 Nos. indication panel each with 6A control MCB as per fault requirementwith ACB 60 1 No. off delay timer for manual operation. 61 Phase Reversal relay 62 8 Window annunciator all compartment 63 Heat shrinkable cable end terminal indoor type cable box 240/300/400 Sq. mm. Size complete all as required to connect incoming and outgoing HT cables to unitized Sub-Station and interconnection of network within the unitized Sub-Station with arc proof shoes. 64 COMPACT SUB-STATION-1000KVA AS DESCRIBED ABOVE 65 H.T. Cable 66 Supplying of following size of Al conductor, XLPE insulated armoured and over all PVC sheathed, 11 KV (E) grade earthed cable as per technical specifications 67 3 core x185Sq. mm YEIDA SOR-2(B) 68 HT Cable laying 69 supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 kV grade as required. 70 3C X185 Sq. mm YEIDA SOR 4(G) 71 S/L of 200mm dia. H.D.P.E. pipe for drawing of power cable across the road by drilling of 220mm dia. at 1mtr. below the road level thereby doing the work of providing H.D.P.E pipe by manual Trenchless method.PE-63/PN-8 complete in all respect, as directed by Engineer in charge YEIDA SOR-23 72 S/F of 11kv HV insulating mats confirming to IS 15652-2006. The mats should have been type tested by CPRI or another third party lab of equivalent stature. The mats shall be moisture proof, fire retardant and resistant to acids, alkalies & transformer oil. Complete in all respects as per direction of the Engineer-in-charge. YEIDA SOR-59 73 Supply and fixing in position the approved “Shock Treatment Charts” written in English and Local Language. These charts shall be framed in teak wood frame and covered with glass. 74 Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 75 Supply and fixing position the approved single line diagram framed in 1000 x 100 mm size glass frame and installed in main LT Panel Room. 76 Supply of tool kit, first aid box with all accessories required for operation and maintainence for 415 volt & 11 kV equipment with 1 pair 11 kV rubber hand gloves of approved make. 77 Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required. 78 SUBHEAD-II-DIESEL GENERATOR SETS 79 FOR - BUILDING NO- 10 80 Supply, installation, testing and commissioning of Prime Duty, Diesel engine driven generating Set (Silent Type) of 1010KVA capacity CPCB-IV compliance to ISO-8528-Part 1 with Genset Controller (DIEF / DeepSea / Woodward or eq) and comprising of following:- 81 The DG Set emission should be as per revised CPCB-IV norms as per the latest notification MOEFCC NOTIFICATION “GSR 804(E) DATED 03.11 .2022 [F.NO. Q-15017/05/2012-CPW 82 a) Diesel Engine 83 Engine developing minimum1010kVA Gross Engine Power at 1500 RPM rated for Prime Duty with an additional 10% overload capacity for one hour in period of twelve hours of continuous operation at standard operation conditions as per ISO 3046-1/1, ISO 15550 inclusive of all standard accessories like Silencer, After Treatment System In Front of Radiator, High Pressure Common Rail (HPCR) Fuel Injection, ECU control providing efficient performance in terms of power & fuel consumption, Electronic Governing of G3 Governing Class and with all standard accessories as per ISO:8528-5.Engine Cooling System must be designed for 50⁰C ambient 84 b) Alternator 85 Synchronous alternator 1010KVA, AC 3 phase, 415 volt, 50 Hz, 1500 RPM, 0.8 lagging power factor alternator shall be in SPDP enclosure, self excited, self regulated, foot mounted with end shield. The alternator shall confirm to IS:13364/IEC 60034 – 1 suitable for tropical conditions.Alternator shall deliver full output at 50 degree C, shall have inbuilt BTD and winding temp. detector along with space heaters. Necessary spaace provision for REF protection with separate earth fault CTs shall be provided inside alternator box. alternator should one heigher rating size for 50 degree amb. 86 c) Automatic Main Failure Panel 87 DG AMF control panel with internal access to facilitate both connection and maintenance complete with 1 No 1600Amps ACB WITH COPPER BUSBAR to loads. Ammeter, Voltmeter, frequency meter, Kh meter etc. including light Set ON/OFF battery charge etc. complete in all respect with power loom between alternator & isolator panel thru CU flexible within the Genset Canopy / Acoustic Enclosure.Engine mounted instrument panel fitted with and having digital/Analog display. 88 d) Acoustic Enclosure 89 The enclosure fabricated from high grade cold rolled close annealed (CRCA) sheet and steel members lined with high density sound absorption material to reduce the sound level to 75 dBA from the original sound level measured at a distance of 1 meter away from the GenSet, under free field conditions compliance to CPCB- IV Noise limit / guidlines for Dg Set below 1000kVA / 800Kwe. Accoustic and weather proof enclosure suitable for the DG Set with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air into the atmosphere as per CPCB-IV norms.The enclosure will be provided with durable industrial locking system with doors duly gas-keted etc., all complete with ARAI Type approval / certification. 90 e) Battery 91 2x12V, 150 Ah Battery assembly with all necessary connecting leads and terminals of reputed make and stand for lead acid Maintinance free battery. Starter Motor Power must be min 8KW 92 f) Base frame 93 Skid mounting type base frame fabricated from suitable size of MS channel / CRCA Sheet providing common bed for engine & alternator directly coupled together with AVM Pads and necessary reinforcement which shall be installed on suitable RCC foundation and vibration isolation arrangement as per recommendations of manufacturer. 94 g) Testing in Works / Factory 95 The DG sets will be tested in the works of the manufacturer for 12 hours at full load including 10% over load before dispatch in the presence of the representative of client . Testing will be crried out as per CPWDs specifications. 96 h) MISC 97 Inbuilt Capacity Day tank of standard capacity . for fuel storage with level markings inside and outside canopy. 98 After Treatment System In Front of Radiator with DEF (diesel exhaust fluid) / AdBlue storage tank of min 35L for urea dosing with proper connection etc. 99 SITC of TP,1600A, Electrical Fix ACB Isolator Panel Outside Canopy with IP4x suitable for Indoor application. Power Cabling b/w DG Set & Isolator Panel included and thes ameneeds to be done at site by electrical contractor. YEIDA RATE- 4.02 100 DG SET 1010 KVA AS PER DESCRIBED ABOVE 101 EXHAUST PIPING 102 Supply and Fixing of MS Exhaust Pipe of dia 350mm class B for 1010KVA DG Set with rain cap. With all accessories etc., complete 103 Supply and fixing of Thermal insulation on MS Exhaust Pipe of dia 350mm class B for 1010 KVA DG Set with 50mm thick LRB/Rock Wool of 96 Kg density per cub mtr. Covered with wire mesh & covered with 24 gauge AI Sheet 104 Supply,testing and commissioning ofAluminium cladding for residential silencerswith LRB Rockwool 50mm Thick, density 64 Kg/cu.mtr., wire mesh and 24 gauge aluminium cladding. complete as required suitable for 1010 Kva DG exhaust pipe temperature upto 450°C. 105 Supply and installation of SS Flexible Bellows, 8 dia. (350 mm NB), complete with counter flanges, heat resistant gaskets, nuts-bolts-washers etc., complete as required. 106 Providing & fixing for MS support structure for exhaust fume pipes from DG Sets (Exhaust pipe to be measured and paid for separately) along horizontal and vertical runs upto the height (as per CPCB norms) including cutting, welding etc and applying two coats of red oxide and two coats of synthetic enamelled paint of colour and shade as directed by client/Architect. The design of the support structure shall be done by the contractor and shall be as per CPCB norms approved , also to get the approval from the consultant before execution etc. as required. 107 Provide & fixing fuel piping with pipe supports, bends, flanges packing, hardwares and painting from main storage tank to day oil tank and day oil tank to DG Set of following sizes 108 25 mm dia Heavy duty (Class C ) MS Pipe 109 VALVES 110 Supply & fixing the following valves of approved make complete with flanges, bolts nuts and gaskets etc., 111 25mm dia gate valve 112 Supply & fixing of 990 Litre (14 SWG thick) fuel oil service tank with oil level indicator with level gauge scale, inlet/outlet connection valve, air vent, pedestal for mounting etc., including 02 Nos if hand fuel transfer pumps 113 Obtaining necessary approvals from the chief electrical inspectorate, if required for electrical safety for 1X 1010kVA Genset. 114 SUBHEAD-III- 15 KVA UPS 115 Supply, installation, testing and commissioningof IGBT Rectifier & Inverter basedUPS system comprising of 1 no 15 kVA units with batterybank backup of 30 minutes duration for full load with all standards fittings, accessories, protection, instruments, indications and controls including but not restricted to transformer, rectifire, inverter, SMF battery with float cum boost battery charger, static bypass switch, maintenance bypass, output isolation transformer, interconnections etc.including warranty and free all inclusive comprehensive maintenance services for two years for UPS and battery bank after the date of handing over complete as per specification and as required.YEIDA RATE - 45.03 116 SUBHEAD-IV-LTPANEL& DISTRIBUTION BOARD 117 Supply,Installation, Testing and Commissioning of dust, damp and vermin proof IP- 4X / 5X free floor standing /wall mounted, Indoor type, form 3B/4A complied factory assembled in sheet steel enclosed modular construction, extendable from both side, fabricated out of CRCA grade d or equivalent sheet steel for load bearing member in 2mm thick and 1.6mm for non-load bearing members and doors with covers, 3mm thick for gland platescomplete with 9 tank pre treatment process for powder coating with minimum 80 to 100 micron electro static powder coating coverage in approved shade of RAL 7032/7035 in elasto polymer type powder, complete with Aluminium bus bars designed for proper temperature rise withstand capacity, inter-connection with copper conductor wires / aluminium strips, neutral links, earth bus etc. including control wiring with 1.5sqmm. & 2.5sqmm. PVC insulated FRLS copper conductor S/C cable for voltage & current respectively, cable alleys, cable gland plates in two half for acb panels, etc. suitable for operation on 415 ±10% volts, 50 Hz AC 3 phase 4 wire system necessary metering protections & indications and mounted with the following switch gears etc. complete as required complying with IEC-61439 Part1&2 . 118 (Each MCCB will have variable current setting for over current and short circuit, front extended lockable handle, pad lockable in off position, indication light for ON, shrouding on incomer side, termination shall be suitable for aluminium bus bars. All MCCBs shall be microprocessor based only otherwise as specified in the boq. 119 All Switchboards shall have provision for entry of cables from the top or bottom as required 120 All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The Busbars shall be fully insulated with heat shrinkable sleeves and should withstand busbar temp. The busbar support insulators should be SMC. Padlocking isolating switches and load break switches lockable in OFF position. The panel shall meet criterias as per Client EHS guideline. 121 All kA ratings indicated shall be Ics = Icu = Icw values 122 Ics value should be 100% 123 GA drawings shall be got approved from Owners/Architects/ Consultants before fabrication. 124 Tube based Clean Agent Fire suppression systemshall be taken for all panels as specified in the boq. 125 All Panel should be Form 4b (For ACB Compartment) &3b combination. 126 MAIN L.T PANELIcs = 50KA 127 Incomers :- 3 Nos numbers (2 x 1600A, 4P EDO ACB from CSS + 1 x 1600A 4P EDO ACBDG. 128 Incomer from CSS of 1010 kVA 129 2 Nos.1600A 4P EDO ACB with microprocessor based communicable release, over current with different time settings, short circuit with time delay & earth fault release with time delay, instantaneous current setting . Suitable links shall be provided for cable termination. ON/OFF/TRIP indication shall be wired through potential free contact up to terminal strip of breaker for hooking to BMS. Each incomer shall have following. 130 1 no. 0-500V 96 sqmm digital voltmeter with selector switch, 3 No. phase indicating lamps to show the incoming power with control 2A TP MCB. 131 3 Nos. indicating lights for ACB on/ off/ trip position. 132 1 No.phase reversal relay with matching cast resin CTs 133 1 no. 3 phase voltage monitoring relay cum phase sequence meter 134 1 No. APFC relay with matching cast resin CTs. 135 Incomer from DGs 136 1No. X 1600A 4P EDO ACB with microprocessor based, over current with different time settings, short circuit with time delay & earth fault release with time delay. Suitable links shall be provided for cable termination. ON/OFF/TRIP indication shall be wired through potential free contact up to terminal strip of breaker for hooking to BMS. Each incomer shall have following. 137 This release shall have RS-485 including showing all parameters on the software before integrating to IBMS 138 1 no. 0-500V 96 sqmm digital voltmeter with selector switch, 3 No. phase indicating lamps to show the incoming power with control 2A TP MCB. 139 3 Nos. indicating lights for ACB on/ off/ trip position. 140 1 No. ON/OFF push buttons. 141 1 No. reverse power relay with matching cast resin CTs 142 1 no. 3 phase voltage monitoring relay cum phase sequence meter 143 Bus Couplers 144 One number 1600A 4 pole EDO ACB microprocessor based over current, short circuit release type as bus coupler. Necessary contacts shall be wired upto terminal strip for breaker ON/OFF/TRIP, providing potential free contact ON/OFF/TRIP for status monitoring in BMS. 145 Bus Bar Section-I & II 146 Two set ofTPN Aluminium bus bar rated for 2000A (after considering all necessary deratings) 3 phase 4wire, 50Hz. A minimum derating factor of 0.80 must be taken for calculation of bus bar sizes. The bus bar size after derating shall be equal to the ampere given in the BOQ. current density of bus-bars shall not be more than 0.8 Amps/sq.mm for Aluminium and earth bus size shall be suitable of system fault level. 147 Outgoings Sections 148 4 Nos. 800A 4P feeder each having one no. 800A 4P EDO ACB 149 3 Nos. 500A 4P feeder each having one no. 500A 4P MCCB. 150 2 Nos. 100A 4P feeder each having one no. 100A 4P MCCB 151 5 Nos. 63A 4P feeder each having one no. 63A 4P MCCB 152 Other items such as 153 PLC for Necessary electrical Interlocking through advance contacts / contactorsin MCCB/ ACBs (Incomers & Bus couplers)should be provided to ensure that only one supply is available at a time on each section of bus and to eliminate any possibility of accidentally approaching two supplies at one bus section as per single line diagram enclosed & as required. 154 Panel with auto and manual operation and Load Manager for both Mains and DG power, whose function will be to determine the Load. Supplier to submit the Bill of materials for the above functions also provide motorised potential meter for each generator for voltage correction. 155 1kVA online UPS with minimum 15 minutes backup built in battery for PLC system. 156 1 Lot of control wiring. 157 1 Set of designation plates 158 Tube based Clean Agent Fire suppression systemshall be taken for panels. 159 MAIN L.T PANEL as describe above and shown in SLD. 160 BUILDING PANEL-01 Ics = 35KA 161 Incomer:- 162 2Nos. X 800A 4P EDO ACB with microprocessor based, over current with different time settings, short circuit with time delay & earth fault release with time delay. Suitable links shall be provided for cable termination. ON/OFF/TRIP indication shall be wired through potential free contact up to terminal strip of breaker for hooking to BMS. Each incomer shall have following. 163 1 no. 0-500V 96 sqmm digital voltmeter with selector switch, 3 No. phase indicating lamps to show the incoming power with control 2A TP MCB. 164 3 Nos. indicating lights for ACB on/ off/ trip position. 165 1 No.phase reversal relay with matching cast resin CTs 166 1 no. 3 phase voltage monitoring relay cum phase sequence meter 167 Bus Bar 168 One set of TPN, AL. bus bar rated 1000Amps (after considering necessary deratingsof 80%) for phases and neutral for half capacity of phases. 169 The outgoing feeders are as follows : 170 3 Nos. 200A 4P feeder each having one no. 200A TP MCCB. 171 4 Nos. 160A 4P feeder each having one no. 160A TP MCCB. 172 Tube based Clean Agent Fire suppression systemshall be taken for panels. 173 1 set of complete wiring 174 Necessary electrical Interlocking through advance contacts / contactorsin MCCB/ ACBs (Incomers & Bus couplers)should be provided to ensure that only one supply is available at a time on each section of bus and to eliminate any possibility of accidentally approaching two supplies at one bus section as per single line diagram enclosed & as required. 175 BUILDING PANEL-01 Ics = 35KA as describe above and shown in SLD. 176 BUILDING PANEL-02Ics = 35KA 177 Incomer:- 178 2Nos. X 800A 4P EDO ACB with microprocessor based, over current with different time settings, short circuit with time delay & earth fault release with time delay. Suitable links shall be provided for cable termination. ON/OFF/TRIP indication shall be wired through potential free contact up to terminal strip of breaker for hooking to BMS. Each incomer shall have following. 179 1 no. 0-500V 96 sqmm digital voltmeter with selector switch, 3 No. phase indicating lamps to show the incoming power with control 2A TP MCB. 180 3 Nos. indicating lights for ACB on/ off/ trip position. 181 1 No.phase reversal relay with matching cast resin CTs 182 1 no. 3 phase voltage monitoring relay cum phase sequence meter 183 Bus Bar 184 One set of TPN, AL. bus bar rated 1000Amps (after considering necessary deratingsof 80%) for phases and neutral for half capacity of phases. 185 The outgoing feeders are as follows : 186 3 Nos. 250A 4P feeder each having one no. 250A TP MCCB. 187 3 Nos. 160A 4P feeder each having one no. 160A TP MCCB. 188 1 No. 125A 4P feeder each having one no. 125A TP MCCB. 189 Tube based Clean Agent Fire suppression systemshall be taken for panels. 190 1 set of complete wiring 191 Necessary electrical Interlocking through advance contacts / contactorsin MCCB/ ACBs (Incomers & Bus couplers)should be provided to ensure that only one supply is available at a time on each section of bus and to eliminate any possibility of accidentally approaching two supplies at one bus section as per single line diagram enclosed & as required. 192 BUILDING PANEL-02 Ics = 35KA as describe above and shown in SLD. 193 COMMON PANELIcs = 35KA 194 Incomer 195 1 No. Incomer 160 Amps 4P MCCB with thermal magnetic releases for O/C, S/C, 3 Nos. phase indicating lamps to show the incoming power with control 2A TP MCB,and 1 no. digital multifunction meter with matching cast resin CTs. 196 Bus Bar 197 One set of TPN, AL. bus bar rated 200Amps (after considering necessary deratingsof 80%) for phases and neutral for half capacity of phases. 198 The outgoing feeders are as follows : 199 1 No. 125A 4P feeder having one no. 125A 4P MCCB . 200 7 Nos. 63Amps 4P feeders each having one number 63 Amps 4P MCB. 201 2 Nos. 40Amps 4P feeders each having one number 40 Amps 4P MCB. 202 Tube based Clean Agent Fire suppression systemshall be taken for panels. 203 1 set of complete wiring 204 COMMON PANEL Ics = 25KA as describe above and shown in SLD. 205 METER BOARD-01 &03 (G.F&F.F )Ics = 35KA 206 Incomer 207 1 No. Incomer 200 Amps 4P MCCB with thermal magnetic releases for O/C, S/C, 3 Nos. phase indicating lamps to show the incoming power with control 2A TP MCB,and 1 no. digital multifunction meter with matching cast resin CTs. 208 Bus Bar 209 One set of TPN, AL. bus bar rated 250Amps (after considering necessary deratingsof 80%) for phases and neutral for half capacity of phases. 210 The outgoing feeders are as follows : 211 1 Nos. 400MM (H) x 375MM(W) Glass window compartment each with Lock & key arrangement including backelite sheet for mounting provided digital Three Phase pre-paid duel source CT operated Energy Meter with RS485 Port for BMS connectivity. Incuding providing and fixing of din channel monted 4P, 100A, MCCB, 25kA with 100A, connecters in cable alley and power wiring between meter and connector via MCCB. 212 6 Nos. 300MM (H) x 375MM(W), Glass window compartment each with Lock & key arrangement including backelite sheet for mounting provided digital Three Phase pre-paid Energy duel source Meter with RS485 Port for BMS connectivity. Incuding providing and fixing of din channel monted 4P, 40A, MCB, 10kA with 63A, connecters in cable alley and power wiring between meter and connector via MCB. 213 2Nos. 40Amps 4P feeders each having one number 40 Amps 4P MCB. 214 Tube based Clean Agent Fire suppression systemshall be taken for panels. 215 1 set of complete wiring 216 METER BOARD-01 &03 (G.F&F.F )Ics = 35KA as describe above and shown in SLD. 217 METER BOARD-02&04 (G.F & F.F )Ics =35KA 218 Incomer 219 1 No. Incomer 160 Amps 4P MCCB with thermal magnetic releases for O/C, S/C, 3 Nos. phase indicating lamps to show the incoming power with control 2A TP MCB,and 1 no. digital multifunction meter with matching cast resin CTs. 220 Bus Bar 221 One set of TPN, AL. bus bar rated 200Amps (after considering necessary deratingsof 80%) for phases and neutral for half capacity of phases. 222 The outgoing feeders are as follows : 223 10 Nos. 300MM (H) x 375MM(W), Glass window compartment each with Lock & key arrangement including backelite sheet for mounting provided digital Three Phase pre-paid Energy duel source Meter with RS485 Port for BMS connectivity. Incuding providing and fixing of din channel monted 4P, 40A, MCB, 10kA with 63A, connecters in cable alley and power wiring between meter and connector via MCB. 224 2 No. 40Amps 4P feeders having one number 40 Amps 4P MCB. 225 Tube based Clean Agent Fire suppression systemshall be taken for panels. 226 1 set of complete wiring 227 METER BOARD-02&04 (G.F&F.F )Ics =35KA as describe above and shown in SLD. 228 METER BOARD-05&07 (S.F & T.F )Ics = 35KA 229 Incomer 230 1 No. Incomer 200 Amps 4P MCCB with thermal magnetic releases for O/C, S/C, 3 Nos. phase indicating lamps to show the incoming power with control 2A TP MCB,and 1 no. digital multifunction meter with matching cast resin CTs. 231 Bus Bar 232 One set of TPN, AL. bus bar rated 300Amps (after considering necessary deratingsof 80%) for phases and neutral for half capacity of phases. 233 The outgoing feeders are as follows : 234 1 Nos. 400MM (H) x 375MM(W) Glass window compartment each with Lock & key arrangement including backelite sheet for mounting provided digital Three Phase pre-paid duel source CT operated Energy Meter with RS485 Port for BMS connectivity. Incuding providing and fixing of din channel monted 4P, 125A, MCCB, 25kA with 125A, connecters in cable alley and power wiring between meter and connector via MCCB. 235 1 No. 300MM (H) x 375MM(W), Glass window compartment each with Lock & key arrangement including backelite sheet for mounting provided digital Three Phase pre-paid Energy duel source Meter with RS485 Port for BMS connectivity. Incuding providing and fixing of din channel monted 4P, 63A, MCB, 10kA with 63A, connecters in cable alley and power wiring between meter and connector via MCB. 236 1 Nos. 125Amps 4P feeders each having one number 125 Amps TP MCB. 237 Tube based Clean Agent Fire suppression systemshall be taken for panels. 238 1 set of complete wiring 239 METER BOARD-05&07 (S.F & T.F )Ics = 35KA as describe above and shown in SLD. 240 METER BOARD-06&08 (S.F&T.F )Ics = 35KA 241 Incomer 242 1 No. Incomer 250 Amps 4P MCCB with thermal magnetic releases for O/C, S/C, 3 Nos. phase indicating lamps to show the incoming power with control 2A TP MCB,and 1 no. digital multifunction meter with matching cast resin CTs. 243 Bus Bar 244 One set of TPN, AL. bus bar rated 250Amps (after considering necessary deratingsof 80%) for phases and neutral for half capacity of phases. 245 The outgoing feeders are as follows : 246 2 Nos. 400MM (H) x 375MM(W) Glass window compartment each with Lock & key arrangement including backelite sheet for mounting provided digital Three Phase pre-paid duel source CT operated Energy Meter with RS485 Port for BMS connectivity. Incuding providing and fixing of din channel monted 4P, 125A, MCCB, 25kA with 125A, connecters in cable alley and power wiring between meter and connector via MCCB. 247 1 Nos. 125Amps 4P feeders each having one number 125 Amps TP MCB. 248 Tube based Clean Agent Fire suppression systemshall be taken for panels. 249 1 set of complete wiring 250 METER BOARD-06&08 (S.F&T.F )Ics = 35KA as describe above and shown in SLD. 251 PRESSURIZATION PANELAT TERRACE (OUTDOOR TYPE)Ics = 25KA 252 Incomer 253 1 No. Incomer 63Amps 4P MCCB with microprocessor based releases for O/C, S/C, 3 Nos. phase indicating lamps to show the incoming power with control 2A TP MCB,and 1 no. digital multifunction meter with matching cast resin CTs. 254 Bus Bar 255 One set of TPN, AL. bus bar rated 200 Amps (after considering necessary deratingsof 80%) for phases and neutral for half capacity of phases. 256 The outgoing feeders are as follows : 257 1 No. of 7.5 amp rating of TP MCCB of 50 kA breaking capacity with 2.2 KW DOL motor starter type iico-ordination along with TP power contactors (AC3) with inbuilt 2NO + 2NC contact with necessary additional potantial free auxiliary contactor oprate starter ON/OFF and remote switching, Red, Green & Yellow Indicating Lamps, Start/Stop Push buttons LED type, Auto/Manual/Off selector switch Complete as required. 258 1No.7.5 Amps TP MCCB with DOL Starter .(Space only) 259 1 set of complete wiring 260 PRESSURIZATION PANELAT TERRACE (OUTDOOR TYPE)Ics = 25KA as describe above and shown in SLD. 261 COMMON AREA VRV PANEL AT TERRACE(OUTDOOR TYPE)Ics = 35KA 262 Incomer 263 1 No. Incomer 125 Amps 4P MCCB with microprocessor based releases for O/C, S/C, 3 Nos. phase indicating lamps to show the incoming power with control 2A TP MCB,and 1 no. digital multifunction meter with matching cast resin CTs. 264 Bus Bar 265 One set of TPN, AL. bus bar rated 200Amps (after considering necessary deratingsof 80%) for phases and neutral for half capacity of phases. 266 The outgoing feeders are as follows : 267 2 Nos. 40Amps 4P feeders each having one number 40 Amps 4P MCB along with 40 4P ELCB (100mA). 268 4 Nos. 32Amps 4P feeders each having one number 32 Amps 4P MCB along with 40 4P ELCB (100mA).. 269 1 set of complete wiring 270 COMMON AREA VRV PANEL AT TERRACE(OUTDOOR TYPE)Ics = 35KA as describe above and shown in SLD. 271 PLUMBING PANEL Ics = 35KA 272 Incomer 273 1 No. Incomer 63Amps 4P MCCB with microprocessor based releases for O/C, S/C, 3 Nos. phase indicating lamps to show the incoming power with control 2A TP MCB,and 1 no. digital multifunction meter with matching cast resin CTs. 274 Bus Bar 275 One set of TPN, AL. bus bar rated 200 Amps (after considering necessary deratingsof 80%) for phases and neutral for half capacity of phases. 276 The outgoing feeders are as follows : 277 2 Nos. of 12 amp rating of TP MCCB of 50 kA breaking capacity with 5 HP DOL motor starter type iico-ordination along with TP power contactors (AC3) with inbuilt 2NO + 2NC contact with necessary additional potantial free auxiliary contactor oprate starter ON/OFF and remote switching, Red, Green & Yellow Indicating Lamps, Start/Stop Push buttons LED type, Auto/Manual/Off selector switch Complete as required. (For Sump Pump -1working&1 standby). 278 2 Nos. of 10 amp rating of TP MCCB of 50 kA breaking capacity with 3 HP DOL motor starter type iico-ordination along with TP power contactors (AC3) with inbuilt 2NO + 2NC contact with necessary additional potantial free auxiliary contactor oprate starter ON/OFF and remote switching, Red, Green & Yellow Indicating Lamps, Start/Stop Push buttons LED type, Auto/Manual/Off selector switch Complete as required. (For Domestic Transfer Pump -1working&1 standby). 279 2 Nos. of 10 amp rating of TP MCCB of 50 kA breaking capacity with 3 HP DOL motor starter type iico-ordination along with TP power contactors (AC3) with inbuilt 2NO + 2NC contact with necessary additional potantial free auxiliary contactor oprate starter ON/OFF and remote switching, Red, Green & Yellow Indicating Lamps, Start/Stop Push buttons LED type, Auto/Manual/Off selector switch Complete as required. (For Flusing Transfer Pump -1working&1 standby). 280 2Nos. of 7.5 amp rating of TP MCCB of 50 kA breaking capacity with 2 HP DOL motor starter type iico-ordination along with TP power contactors (AC3) with inbuilt 2NO + 2NC contact with necessary additional potantial free auxiliary contactor oprate starter ON/OFF and remote switching, Red, Green & Yellow Indicating Lamps, Start/Stop Push buttons LED type, Auto/Manual/Off selector switch Complete as required.(For Flusing Booster Pump -1working&1 standby). 281 2No. of 7.5 amp rating of TP MCCB of 50 kA breaking capacity with1 HP DOL motor starter type iico-ordination along with TP power contactors (AC3) with inbuilt 2NO + 2NC contact with necessary additional potantial free auxiliary contactor oprate starter ON/OFF and remote switching, Red, Green & Yellow Indicating Lamps, Start/Stop Push buttons LED type, Auto/Manual/Off selector switch Complete as required.(1working&1 standby). 282 1No.32 Amps DP MCB 283 1 set of complete wiring 284 PLUMBING PANEL Ics = 35KA Ics = 35KA as describe above and shown in SLD. 285 320KVAR Capacitor PanelIcs = 35KA 286 320KVAR CAPACITOR PANELS (5X50 KVAR + 1X25KVAR + 3X10KVAR+ 3X5KVAR) 287 Supplying, installation, testing & commissioning of factory built floor mounted auto-manualpower factor correction system panel of 320KVAR capacity having 3 phase, Mixed Die Electric(total power loss not exceeding 0.50 W/ KVAR) power capacitor in eleven steps, filled with suitable oil and; provided with 10KVAR fixed capacity and balance Electronic Thyristor switching & detuned filters (min.7%) to supress switching of inrush current and reducing harmonics to improve capcitor life. 288 The system Shall be provided with required capacity master MCCB, to control its main operating parameters such as over loads, short circuit, etc. 289 The panel shall be fabricated in compartmentalized design from CRCA sheet steel of 2mm thick for frame work and covers, having 800 Amp capacity extensible type TPN Aluminium Alloy bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 35 MVA for I Sec., bottom base channel of MS section not less than 100mm x 50mm x 5mm thick, fabrication shall be done in transportable sections, entire panel shall have a common GI earth bar of size 75 mm x 10 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears/ accessorieswith required size of Al. bus bars and control wiring with 2.5 sq.mm. PVC insulated FRLS copper conductor Single Core cable, of2 mm thick MS Sheet, provided with exhaust fans (with thermostat) and grills for proper ventilation, interconnections with suitable size conductor cables & lugs and accommodating the following swicthgears & accessories: 290 800Amp 3 Pole ACB- 1 No. 291 LED Indicating light - 12 Nos. 292 One numbers dual source, dual setting, binary typeautomatic power factor sensing and correction relay (12stages) complete with its all accessories etc. asrequired. 293 MCCBof following capacity with spreader link and phase barrier 294 125 A, 3P,MCCB - 5Nos. 295 63 A, 3P,MCCB - 1 Nos. 296 32 A, 3P,MCCB- 6 Nos. 297 L.T. Powerfactorimprovingcapacitor of indoortypesuitable for operation on415 volts AC 3 phase 50 Hzcomplete with bankingarrangement, interconnections with suitable size ofcopper conductor PVCinsulated PVC sheathedunarmoured cable, dischargeresistance etc. as required. 298 Bank of50 KVArrating -5 Sets 299 Bank of 25 KVAr rating -1 Set. 300 Bank of 10 KVAr rating -1 Set. (FIXED TYPE). 301 Bank of 10 KVAr rating - 2 Set 302 Bank of5 KVAr rating -3 Set 303 APFC Panel as described above and shown in SLD 304 OFFICE PANEL-1&5 AT S.F & T.FIcs = 35KA 305 Incomer 306 1 No. Incomer 125 Amps 4P MCCB with microprocessor based releases for O/C, S/C, 3 Nos. phase indicating lamps to show the incoming power with control 2A TP MCB,and 1 no. digital multifunction meter with matching cast resin CTs. 307 Bus Bar 308 One set of TPN, AL. bus bar rated 200Amps (after considering necessary deratingsof 80%) for phases and neutral for half capacity of phases. 309 The outgoing feeders are as follows : 310 2 Nos. 100Amps 4P feeders each having one number 100 Amps 4P MCCB. 311 2 Nos. 63Amps 4P feeders each having one number 63 Amps 4P MCB. 312 1 set of complete wiring 313 OFFICE PANEL-1&5 AT S.F & T.FIcs = 35KA as describe above and shown in SLD. 314 OFFICE PANEL-2,3&7 AT S.F & T.FIcs = 35KA 315 Incomer 316 1 No. Incomer 125 Amps 4P MCCB with microprocessor based releases for O/C, S/C, 3 Nos. phase indicating lamps to show the incoming power with control 2A TP MCB,and 1 no. digital multifunction meter with matching cast resin CTs. 317 Bus Bar 318 One set of TPN, AL. bus bar rated 200Amps (after considering necessary deratingsof 80%) for phases and neutral for half capacity of phases. 319 The outgoing feeders are as follows : 320 1 Nos. 100Amps 4P feeders having one number 100 Amps 4P MCCB. 321 4 Nos. 63Amps 4P feeders each having one number 63 Amps 4P MCB. 322 1 set of complete wiring 323 OFFICE PANEL-2,3&7 AT S.F & T.FIcs = 35KA as describe above and shown in SLD. 324 OFFICE PANEL-6 ATT.FIcs = 35KA 325 Incomer 326 1 No. Incomer 125 Amps 4P MCCB with microprocessor based releases for O/C, S/C, 3 Nos. phase indicating lamps to show the incoming power with control 2A TP MCB,and 1 no. digital multifunction meter with matching cast resin CTs. 327 Bus Bar 328 One set of TPN, AL. bus bar rated 200Amps (after considering necessary deratingsof 80%) for phases and neutral for half capacity of phases. 329 The outgoing feeders are as follows : 330 2 Nos. 100Amps 4P feeders each having one number 100 Amps 4P MCCB. 331 2 Nos. 63Amps 4P feeders each having one number 63 Amps 4P MCB. 332 1 set of complete wiring 333 OFFICE PANEL-6 ATT.FIcs = 35KA as describe above and shown in SLD. 334 OFFICE PANEL-4&8 ATS.F& T.FIcs = 35KA 335 Incomer 336 1 No. Incomer 100 Amps 4P MCCB with microprocessor based releases for O/C, S/C, 3 Nos. phase indicating lamps to show the incoming power with control 2A TP MCB,and 1 no. digital multifunction meter with matching cast resin CTs. 337 Bus Bar 338 One set of TPN, AL. bus bar rated 200Amps (after considering necessary deratingsof 80%) for phases and neutral for half capacity of phases. 339 The outgoing feeders are as follows : 340 2 Nos. 63Amps 4P feeders each having one number 63 Amps 4P MCB. 341 1 No. 40Amps 4P feeders having one number 40 Amps 4P MCB . 342 1 set of complete wiring 343 OFFICE PANEL-4&8 ATS.F& T.FIcs = 35KA as describe above and shown in SLD. 344 HVAC PANEL-1ATTERRACEIcs = 35KA(Outdoor Type) 345 Incomer 346 1 No. Incomer 100 Amps 4P MCCB with microprocessor based releases for O/C, S/C, 3 Nos. phase indicating lamps to show the incoming power with control 2A TP MCB,and 1 no. digital multifunction meter with matching cast resin CTs. 347 Bus Bar 348 One set of TPN, AL. bus bar rated 200Amps (after considering necessary deratingsof 80%) for phases and neutral for half capacity of phases. 349 The outgoing feeders are as follows : 350 2 Nos. 63Amps 4P feeders each having one number 63 Amps 4P MCB along with 63Amp. 4P ELCB (100mA). 351 1 No. 32Amps 4P feeders having one number 32 Amps 4P MCB along with 40Amp 4P ELCB (100mA). 352 1 set of complete wiring 353 HVAC PANEL-1ATTERRACEIcs = 35KA (Outdoor Type) as describe above and shown in SLD. 354 HVAC PANEL-2,3&7ATTERRACEIcs = 35KA (Outdoor Type) 355 Incomer 356 1 No. Incomer 100 Amps 4P MCCB with microprocessor based releases for O/C, S/C, 3 Nos. phase indicating lamps to show the incoming power with control 2A TP MCB,and 1 no. digital multifunction meter with matching cast resin CTs. 357 Bus Bar 358 One set of TPN, AL. bus bar rated 200Amps (after considering necessary deratingsof 80%) for phases and neutral for half capacity of phases. 359 The outgoing feeders are as follows : 360 2 Nos. 40Amps 4P feeders each having one number 40 Amps 4P MCB along with 40 Amp. 4P ELCB (100mA). 361 1 No. 32Amps 4P feeders having one number 32 Amps 4P MCB along with 40Amp 4P ELCB (100mA). 362 1 set of complete wiring 363 HVAC PANEL-2,3&7ATTERRACEIcs = 35KA (Outdoor Type) as describe above and shown in SLD. 364 HVAC PANEL-5 &6ATTERRACEIcs = 35KA (Outdoor Type) 365 Incomer 366 1 No. Incomer 100 Amps 4P MCCB with microprocessor based releases for O/C, S/C, 3 Nos. phase indicating lamps to show the incoming power with control 2A TP MCB,and 1 no. digital multifunction meter with matching cast resin CTs. 367 Bus Bar 368 One set of TPN, AL. bus bar rated 200Amps (after considering necessary deratingsof 80%) for phases and neutral for half capacity of phases. 369 The outgoing feeders are as follows : 370 3 Nos. 63Amps 4P feeders each having one number 63 Amps 4P MCB along with 63Amp. 4P ELCB (100mA). 371 1 No. 32Amps 4P feeders having one number 32 Amps 4P MCB along with 40Amp 4P ELCB (100mA). 372 1 set of complete wiring 373 HVAC PANEL-5 &6 ATTERRACEIcs = 35KA (Outdoor Type) as describe above and shown in SLD. 374 Design, Manufacture, Supplying, loading & unloading assembling at site, installation, fixing on the position, testing & commissioning of the following cubical type, dead front, 2.5mm thick sheet steel enclosed, 1600Amp, 4P, MDO, ACB-50kA, without protection relays in 2.5 MM Thick sheet metal enclosed Out door to be located near D.G Set, including emergency push bottom with key lock and provide 5 Nos indicating lamps for status indication ON,OFF , tripped due to fault, DC supply healthy and spring charged complete as required. confirm to degree of protectio IP:55. Also provide M.S. Stand made height 600mm. Maximim height of panel should not be more then 2000mtr. 375 S & F surface/Flush mounting 4ways TPN distribution board with additional metal door without MCB complete in all respect,as directed at site by Engineer in charge. (For Lift). 376 S & F surface/Flush mounting 4ways V TPN distribution board with additional metal door without MCB complete in all respect,as directed at site by Engineer in charge. (For UPS O/P) 377 S&F of 80 to 100 Amp 4 pole MCCB (16 KA) Thermal Magnetic release (For UPS O/P DB Incomer) 378 S&F of 63 Amp. 4 pole MCB(10 KA) C Curve (LIFT DB ICOMER) 379 S&F of 6 Amp. to 32 Amp. TP MCB (10 KA) C Curve ( For UPS O/PDB & LIFT DB Outgoing ) 380 S&F and making connection of 40 Amp. 4 pole 30mA ELCB/RCCB of Din Rail Mounting complete in all respect as per direction and satisfaction to the Engineer in charge. (For Lifts) 381 Prepaid Meters 382 Supply , Installation & Commissiong of Dual source- 3 Phase, BIS-13779,BIS 15884 approved, class-1,Static meter 10-60Amp, including software license with RS 485 communication protocols and load manager including thimbling of power and control cables. Metere display show all the basic electrical parameters (V, A,KW,KVA,P.F, KWH / KVAH ).Model No. PE5120 383 Supply , Installation & Commissiong of Dual source- 3 Phase, BIS-13779,BIS 15884 approved, class-1,Static meter ct operated , including software license with RS 485 communication protocols and load manager including thimbling of power and control cables. Metere display show all the basic electrical parameters (V, A,KW,KVA,P.F, KWH / KVAH ).Model No. PE5120 384 Supply , Installation & Commissioning ofGateway RS485 to Ethernet Converter( Ethernet converter make : Elmeasure) MODEL NO :- GW1500 L 385 Supply , Installation & Commissioning of Software for pre / post metering with facilities:-1. Option configure meter for sanctioned load, terrif, happy hours day2. Option to recharge meter/ bill payment generation.3. Online portals for flat owners to check meter detail & online payment4. Report generation.Mobile app for administrators as well as individuals (Price of this item is excluded in energy meter price) (Make :- Elmeasure) 386 Energy meter sensing Cable :-Supply , Installation & Commissiong 2 Core 0.5 Sq.RS 485, tinted copper communication cablein conduit (meter to meter loop and connected to gateway) 387 DG sensing cable:-Supply , Installation & Commissiong 2 core 1.5mm flexible power cable for DG sensing 388 Supply , Installation & Commissiong of 9 Port Unmanaged switches as per the requirement. 389 SITC of Payment gateway for online recharge facility.(MYgate or NoBrokerHood)including SMS gateway for one year for alerts,(SMS alert if DG sensing is not done in any energy meters). 390 Supply, installation, testing & commissioning of Computer System with Configuration: System Processor - HP ML10, XEON E3 or Higher Version, Operating- System - Windows 10, RAM- 16GB or More, HDD 1 TB, Monitor 17 inch, Keyboard and Mouse. Standard warranty 3 yrs. direct from HP or equivalentThe software should be inclusive of the following:- 1) Connectivity to all meter to the PC.2) Monitoring the Grid & Supply Enery based on real time data.3) Generate the Electricity Bill for Clients.4) Pre paid system with Meter charging app to charge the meter through Paytm, Internet banking, Gpay, Phonepay, Bhim etc as per current payment scenario. Also it shall be capable to show the real time data i.e balance amount, daily basis consumption etc on user / client mobile / any other devices.5) Automatically Maintenance charges deduction. 6) Check & Balance of total energy and energy losses.7) Automatic Alert / Massage to Client / Users for Low Balance. 391 Supply , Installation & Commissiong of Cat 6 cable supply for for network end to end connectivity between meter board and server room 392 Supply , Installation & Commissiong of Cat 6 patch cord for network connectivity between DLC & MC. 393 SUB HEAD-V-STREET LIGHTING ELECTRICAL WORKS 394 Supply,unloading at site of following Outdoor type feeder pillar double door lockable type with epoxy paint. This panel shall be mounting on MS/brick pedestal support upto 400mm high from ground level,cubical, dust, vermin proof and outdoor type (IP65) fabricated as per specification laid in document with following incomming and outgoing feeders including making connections/inter-connections testing and earthing etc. required. 395 Feeder Pillar-01(Outdoor Type - IP 65)Ics=25 KA (FOR EXTERNAL LIGHTING) 396 Incomer:- 397 1 No. Incomer 63Amps 4P, MCCBwith microprocessor based O/C, S/C protections having 3 Nos. phase indicating lamps to show the incoming power control with MCB & 1 no. digital voltmeter with separate selector switch, 1 no. ON/OFF indication 398 63A TP,Cont with ON/ OFF indication lamp,ON/ OFF /TRIP,A/M Switch,Start/Stop push button and along with synchronizing 24 hours timer in auto mode. 399 Bus Bar : 400 A set of TPN, Cu. bus bar rated 150 Amps (after considering necessary deratings of minimum 0.80) for phases and neutral for half capacity of phases. 401 The outgoing feeders as follow: 402 4 Nos.16A 4P outgoing feeder each having 1 no. 16A 4P MCB 403 4 Nos.16A DP outgoing feeder each having 1 no. 16A DP MCB 404 3 Nos. 32 DP outgoing feeder each having 1 no. 32A DP MCB. (connected Before Timer and contector) 405 2Nos.16A 4P outgoing feeder each having 1 no.16A DP MCB(Spare) 406 1 set of complete wiring 407 External Lighting Panel as described above and shown in SLD 408 CABLE SUPPLY, LAYING & TERMINATION 409 Supply & laying of PVC insulated PVC sheathed armoured / unarmored aluminium/copper conductor cable directly in ground.The laying involves digging, making sand cushion cover on top and bottom of cable, providing brick support and filling with excavated earth for following sizes. 410 4c x 16 sqmm Al. Arm xlpe cable 411 3c x 4 sqmm cu. Arm xlpe cable 412 3c x 2.5 sqmm cu. Arm xlpe cable 413 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 414 4c x 16sqmm Al. Arm xlpe cable 415 3c x 4 sqmm cu. Arm xlpe cable 416 3c x 2.5 sqmm cu. Arm xlpe cable 417 POLES 418 Supply & fixing of 7 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with single arm bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect. 419 Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 45 watt to 50 Watt. Confirming to IP 66 protection complete in all respect. 420 CAT- AAA 421 Supply and fixing of decorative 8 to 16 Watt LED bollard luminaire with driver set confirming to IP 65 protection complete in all respect. 422 SUBHEAD-VI-LIGHTNING CONDUCTOR 423 Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. 424 Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. 425 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) 426 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) 427 Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. 428 Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required. 429 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 430 SUB HEAD VII- EARTHING 431 Supply and burying of 40mm dia x 4.5 metres long G.I. Pipe vertically for earthing having 12mm dia. Holes spaced 75mm apart drilled up to 2 metre from the bottom complete with earthing lead of No. 6 to 8SWG GI wire in G.I. Pipe up to appron (and from appron to switch board the cost of G.I. wire and pipe will be extra) upto switch board, 30cm square C.I. box with hinged cover masonary enclosure, funnel at top, alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respects as per drawing. 432 Supply and burying of 600mm x 600mm x 6mm G.I.plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and one earthing lead of two no. 8 to 10 SWG GI wire in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc.as per directions of Engineer-in-charge complete in all respect. 433 Supply and burying of 600mm x 600mm x 3mm copper plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and two earthing lead of two no. 8 SWG copper wire in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. pipeand copper wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc.complete in all respect. 434 Supply and laying of 32mm x 6mm copper strip from earth electrode directly in the ground as required complete in all respect. 435 Supply and laying of 25mm x 5mm G.I. strip from earth electrode directly in the ground as required complete in all respect. 436 Supply and fixing of one number 8 SWG G.I. wire in 15mm dia. G.I. pipe for earthing, laid in ground or in wall duly concealed including the cost of cement, sand, labour, T&P other material required for proper completion of the work as directed at site. 437 Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required. 438 Providing and fixing earth bus of 50 mm X 5 mm G.I strip on surface for connections etc. as required. 439 SUBHEAD-VIII-MV CABLE SUPPLY, LAYING AND TERMINATION 440 Supply of the following 1100 volts grade, Aluminium/Copper conductor, XLPE insulated, PVC sheathed, steel armoured/Unarmoured cables as per IS 7098 Part-1and as per technical specifications of this tender and directions of Engineer-in-Charge. 441 4 CORES AL. CONDUCTOR 442 16 sq.mm. Al Ar. XLPE cable 443 25 sq.mm. Al Ar. XLPE cable 444 3.5 CORES AL. CONDUCTOR 445 35 sq.mm. Al Ar. XLPE cable 446 50 sq.mm. Al Ar. XLPE cable 447 70 sq.mm. Al Ar. XLPE cable 448 95 sq.mm. Al Ar. XLPE cable 449 185 sq.mm. Al Ar. XLPE cable 450 300 sq.mm. Al Ar. XLPE cable 451 4 CORES Cu. CONDUCTOR 452 10 sq.mm. Cu. PVC Ar. cable 453 Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required. 454 MV CABLE JOINTING & END TERMINATION 455 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.(Y-34) 456 3½ X 35 sq. mm (32mm) 457 3½ X 50 sq. mm (35mm) 458 3½ X 70 sq. mm (38mm) 459 3½ X 95 sq. mm (45mm) 460 3½ X 185 sq. mm (57mm) 461 3½ X 300 sq. mm (70mm) 462 4 X 16 sq. mm (28mm) 463 4 X 25 sq. mm (28mm) 464 Supplying and making end termination with brass compression gland andCu lugs for following size of PVC insulated and PVC sheathed / XLPEcu conductor cable of 1.1 KV grade as required. 465 10 sq.mm. Cu. PVC Ar. cable 466 Supply, Unloading, shifting, Storing, Laying, Fixing, Testing, Commissioning & Single compression heavy duty glandsoffollowing sizes of Control Cables, Solid Copper conductor single stranded conductor, XLPE Insulated, cores laid up, PVC tape / Extruded Inner sheathed ,Glavanised round wire Armour, extruded PVC Type, 650V grade on existing cable trays/ in existing hume pipes/ PVC pipes/ GI pipes/ on surface of slabs, walls or masonary/ RCC trenches/ ducts including cables ties, GI saddles, clamps and necessary hard ware. 467 6 core x 2.5 sq. mm cable 468 10 core x 2.5 sq. mm cable 469 24 core x 2.5 sq. mm cable 470 SUBHEAD-IX-CABLE TRAYS 471 Hot Dipped Galvanized Iron Cable Tray 472 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 473 150 mm width X 50 mm depth X 1.6 mm thickness 474 300 mm width X 50 mm depth X 1.6 mm thickness 475 450 mm width X 50 mm depth X 2.0 mm thickness 476 600 mm width X 50 mm depth X 2.0 mm thickness 477 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray bends (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 478 150 mm width X 50 mm depth X 1.6 mm thickness 479 300 mm width X 50 mm depth X 1.6 mm thickness 480 450 mm width X 50 mm depth X 2.0 mm thickness 481 600 mm width X 50 mm depth X 2.0 mm thickness 482 Supplying and installing following size of perforated hot dipped galvanised iron cable tray tee (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 483 150 mm width X 50 mm depth X 1.6 mm thickness 484 300 mm width X 50 mm depth X 1.6 mm thickness 485 450 mm width X 50 mm depth X 2.0 mm thickness 486 600 mm width X 50 mm depth X 2.0 mm thickness 487 SUB-HEAD X-GAS Suppression System for Panels 488 SITC of DLP Direct Low Pressure with UL-Listed Lightweight Non-Corrosive Aluminium Cylinder with High grade Stainless Steel 304 Valve Body, Highgrade Brass Isolation Ball Valve 40 bar, High stainless steel Cylinder Mounting Bracket, UL Listed Pressure switch with factory-set for operation, double-throw configuration provides versatile control. The switch is equipped with an O-ring connection for secure, leak-free operation.,High Grade Stainless Steel 304 End of Line (EOL) adaptor with slip-on straight union and Pressure gauge, Stainless Steel 304 Schrader Adaptor with (removable) Pressure Gauge (to indicate pressure of the cylinder) Stainless steelsyphon Tube. Valve filled with CLEAN AGENT 3M NOVEC 1230/AFX-FK-1230 Gas and All components must have ATEX,UL,UKAP,LPCB and IAF approvals.Bidder or supplier must have to submit the OEMsAuthorisation letter and product approvals at the time of bid submission for the warrenty and product assurence. Approved make list- Regulas, AFX-(T), Janus. 489 DLP 4 KG System filled with 3M Novec-1230/AFX-FK-1230 (UL approved) Clean Agent Gas. 490 DLP 2 KG System filled with 3M Novec-1230/AFX-FK-1230 (UL approved) Clean Agent Gas. 491 DLP 1 KG System withfilled with 3M Novec-1230/AFX-FK-1230 (UL approved) Clean Agent Gas. 492 SITC offire detection tube The tube shall be UL Listed, made of modified polyamide, has an internal diameter of 4mm and an external diameter of 6mm. It operates under pressures ranging from 15 to 18 bar, with a minimum burst pressure of 123 bar. The tube is designed with excellent resistance to ozone and UV degradation test certificate to be attached. The bend radius of the tube is 42mm, making it flexible and adaptable to various installation environments. 493 SITC of End of line plug for automatic fire suppression system used for fitting at tube end to terminate the point. Fitting made by brass nickel plated material. 494 SITC of Tee connection 6/6mm Dual Seal Slip-on Swivel Tee High grade Brass Nickle plated material with maxmium pressure 25bar. 495 The stainless steel end-of-line adapter is equipped with a non-return valve and is compatible with 4/6mm tubing. It operates within a pressure range of 13–25 bar, with a maximum pressure of 72 bar, and is designed to withstand temperatures from -20°C to +120°C. 496 SITC of Master Control Unit 2 Zone with audio visual alarm control panel, 2 NO/NC potential free relay contacts discharhe LED indicator, Battery LED indicator system stuts indicator and AC power On LED indicator. 497 SUB HEAD - I - (WET RISERSYSTEM - PUMPING EQUIPMENTS) 498 Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : 499 Horizontal type, multistage, centrifugal, split casing pump of cast iron body & steel Stainless impeller with stainless steel shaft, mechanical seal complete. 500 Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS-325. 501 M.S. fabricated Common base plate, coupling, coupling guard, pressure switch , pressure gauge , vibration eliminator pads , foundation bolts etc. as required. 502 Suitable cement concrete foundation duly plastered with anti vibration pads. 503 2280 lpm at 70 m Head 504 Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) 505 Horizontal type, multistage, centrifugal, split casing pump of cast iron body & steel Stainless impeller with stainless steel shaft, mechanical seal complete. 506 Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 15 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. 507 M.S. fabricated Common base plate, coupling, coupling guard, pressure switch , pressure gauge , vibration eliminator pads , foundation bolts etc. as required. 508 Suitable cement concrete foundation duly plastered and with anti vibration pads. 509 2280 lpm at 70 m Head 510 Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) 511 Horizontal type, multistage, centrifugal, split casing pump of cast iron body & steel Stainless impeller with stainless steel shaft, mechanical seal complete. 512 Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS : 325. 513 M.S. fabricated Common base plate, coupling, coupling guard, pressure switch , pressure gauge , vibration eliminator pads , foundation bolts etc. as required. 514 Suitable cement concrete foundation duly plastered and with anti vibration pads. 515 180 lpm at 70 m Head 516 Supplying and fixing air vessel made of 250 mm dia, 8mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shadeas required. . 517 Providing, installation, testing and commissioning of stainless steel Ystrainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange 518 80 mm dia 519 150 mm dia 520 250 mm dia 521 Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required : 522 250 mm dia 523 200 mm dia 524 150 mm dia 525 80 mm dia 526 Providing and fixing of Rubber Flexible Coupling with Control Unit PN:16 including Matching flanges & fastner. 527 150 mm dia 528 80 mm dia 529 SUB HEAD - II - (HYDRANTS SYSTEM) 530 Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required : 531 Single headed Stainless steel 532 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : 533 Stainless Steel (Grade 304) 534 Supplying & fixing 63 mm dia gun metal short branch pipe with 20mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required: 535 Stainless Steel (Grade 304) 536 Providing, installation, testing and commissioningweatherproof lockable cabinet of size not less than0.90 x 0.60 x 0.30 mtr made out of M.S. sheet 2mm thick havingcentral openingand 6 mmthick glazedglass doors (Two nos.)suitably markedon the outside with the letters FIRE HOSE including necessary lockingarrangement and shall be painted with one coat of primer and two coats of synthetic enamel paint of approved shade as required as per specifications. 537 Supplying, installation, testing and commissioning of fire brigade connection of cast iron body with gun metal male & female instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 538 2 way - 100 mm dia M.S. Pipe 539 4 way - 150 mm dia M.S. Pipe 540 Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. 541 Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required 542 SUB HEAD - III - (PIPING, VALVES AND ACCESSORIES) 543 MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 544 150 mm dia 545 200 mm dia (wall thickness 6.3 mm) 546 250 mm dia (wall thickness 6.3 mm) 547 Providing, laying, jointing, testing & commissioning of heavy classM.S. pipes conforming to IS: 1239/3589 complete with fittings including trenching ,refilling and wraping coating etc.(external work) including all fittings andaccessories like tees, elbows, flanged joints, rubber insertion, nuts, bolts or cutting and welding joints. Providing thrust block at distance specified as per specifications. (Pipe shall be provided with anti corrosive protective treatment with coal tar/asphalt tape confirming to IS: 10221 standard complete as per specification). All work complete as per specification and as directed by Engineer-In-Charge. (All the fitting i.e. tee /elbow etc. for Valve connections etc. will be flanged joints). 548 150 mm dia 549 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 550 80 mm dia 551 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 552 80 mm dia 553 150 mm dia 554 200 mm dia 555 Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronzeworkingpartscomprisingofwatermotor alarm, bronze seat clapper, clapper arm and hydraulically drivenmechanical gong bell to sound continuousalarmwhen thewet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve completewith drainvalveandbypass, test control box, ball valves, MSpipeof requiredsize, flanges,orificeplate,gasket etc of follwing sizes as required : 556 150mm dia 557 SUB HEAD - IV - (FIRE EXTINGUISHERS) 558 Supply, installation, testing and commissioning of ISI marked Fire and wall suspension bracket fire Extinguisher, Trolley mounted carbon-dioxide type capacity 25 Kg. conforming to IS: 2878 Flat base including valve, discharge hose of not less than 10mm dia 1m long complete in all respects including wheeled trolley, carrying handle and initial fill with CO2 gas as per IS: 307-1996 filled to a filling ratio of not more than 0.667. 559 Supply, installation, testing and commissioning in position approved make fire bucket of 24 gauge, galvanized steel, standard 9 liters capacity and of round bottom shape, painted white inside and red outside and black on bottom dome with letters ‘FIRE’ in black and gold with all mounting bracket and screws. 560 Supply, installation, testing and commissioning of fire Bucket Stand including sheet metal (16 gauge) shade for 5 buckets. Platform and associated civil works complete. 561 SUB HEAD - V - (ELECTRICAL PANEL) 562 Fire Fighting Main Panel 563 Incoming 564 800A, 50kA 4 Pole MCCB, Ics=100% Icu rating 565 Digital Voltmeter 0-500V with selector switch 566 Digital Ammeter (0-800 A) with selector swtich & CTs etc. 567 LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps 568 Set of Copper Bus Bar 300A 569 OUTGOING 570 ( Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps) 571 Main Fire Pump 572 250 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 100 HP pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. - 2sets 573 Jockey Pump 574 63 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. - 2sets 575 DIESEL ENGINE CONTROL 576 Control for diesel engine comprising - 577 Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode 578 Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication 579 Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0-20 A DC Ammeter 580 All standard relays and accessories for automatic operation of diesel engine 581 System Controller 582 Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification. Fire panel as above
Contract Date : 21 Aug, 2025   |   Contract Value : 4.69 Crore
BRR : 7766667 Tender For Upgradation Work At Industrial Area Rangwasa, Dist. Indore - Construction of 12 Meter wide CC road - Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300mm, removel of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned up to a lead of 1000 metres including removel and disposal of top organic soil not exceeding 150 mm in thickness if required and as per relevant clauses of section-200 (B) In area of Light jungle For 12 mtr wde road Hectare 0.47 22,918.00 3.3 Excavation for roadwork in soil with hydraulic excavator including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location with all lifts and lead upto 1000m as per relevent clauses of section-300 of specification. Road i/c Footpath CuM 1872.00 55.00 3.4 Excavation in Ordinary Rock using Hydraulic Excavator and Tippers with disposal upto 1000 metres.Excavation for roadway in ordinary rock with hydraulic excavator including cutting and loading in tippers, transporting to embankment site with in all lifts and lead upto 1000 m, trimming bottom and side slopes in accordance with requirements of lines, grades and cross sections as per relevent clauses of section-300 of specification CuM 1872.00 75.00 3.5 Excavation in Hard Rock with disposal upto 1000 metres Excavation for roadway in hard rock with rock breakers i/c breaking rock or by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross sections, loading and disposal of cut road with all lifts and leads upto 1000 metres and as per relevent clauses of section-300 of specification. CuM 1404.00 203.00 3.13 Embankment Construction with Material Obtained from Borrow Pits Construction of embankment with approved material having CBR>7 obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-1, 300-2 and as per relevent clauses of section300. Embankment/ Sub grade CuM 2340.00 2340.00 155 4.12 Crusher Run Macadam Sub Base/Base Course Providing crushed stone aggregate, depositing on a prepared surface by hauling vehicles, spreading and mixing with a motor grader, watering and compacting with a vibratory roller to clause 410 to form a layer of subbase/Base in accordance to Table No. 400-14, 400-15 and as per clause of section 407 of specifications. (i) For 53 mm maximum size Carriageway CuM 386.10 1,145.00 6.1 Dry lean cement concrete Sub-base Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing as per clause 601 of specification complete in all respect. NAME OF WORK : UPGRADATION WORK OF I/A RANGWASA , INDORE BILL OF QUANTITIES Construction of 12 Meter wide CC road 1 2 3 Sr. No. MP PWD Road & Bridge SOR 2022, MPPWD Building Description of Item Unit Qty Rate 5 6 7 4 Road 12M ROW Sr. No. MP PWD Road & Bridge SOR 2022, MPPWD Building Description of Item Unit Qty Rate Carriageway Cum 234.00 2,767.00 6.3 Cement Concrete Pavement Construction of un-reinforced, dowel jointed, plain cement concrete pavement M-40 grade concrete over a prepared sub base with cement, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, admixtures as approved,curing compound, finishing to lines and grades as per drawing as per IRC 15 2011 and as per relevant clauses of section 602 of specifications complete but excluding cost of steel in dowel bar and tie rods etc. Carriageway Cum 643.50 6,103.00 9 6.8 Add extra in Item No.6.3, 6.4, 6.6 & 6.10 above for the cost of steel in dowel bar and tie rod including craddle, laps etc. complete required as per design. 6.8.1 Mild Steel dowel bars 32mm Dia @ 300 C/c Carriageway MT 5.25 3% extra for junction 0.16 Total MT 5.40 63587.00 6.8.2 Tie Bar 12 mm Dia @ 600 C/c Carriageway MT 0.37 Total MT 0.37 68297.00 8.25 Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beeds on Concrete surface. Providing and applying (Cleaning of concrete surface and after applying Concrete primer) thermoplastic compound having composition of binder (Regin) minimum 18 %, titanium dioxide minimum 10 % and intermixed glass beed, minimum 30% of brand like Asian, Burger or equivalent make of 2.5 mm thick including drop down reflectorizing, glass beeds @ 250 gms per sqm area thickness of 2.5 mm is exclusive of surface applied glass beeds as per IRC:35 along with concrete primer. The finished surface to be level, uniform and free from streaks and holes, all complete as per clause 803 of specifications. Note:- The guarantee of Thermoplastic should be minimum 3 Years. sqm 97.50 636.00 11 8.19 Supplying and installation road delineators (road way indicators). as per MORT&H Clause 806. The structure shall be made in roll forming process having height of 80-100 cm above the ground level, width not less than 100 mm and shall extend not more than 300mm below the ground while being installed, buried or pressed in to the ground in confirmation with IRC:79: 1981, are as directed by the by. the Engineer painted black with powder coat of minimum 40 microns thickness for protection against corrosion, on top of which Type XI retro reflective sheeting shall be pasted on both sides complying to IRC:79:1981. The delineator should consist of minimum retro reflective unit exposed area of 330 cm2 white color, full cube corner micro prismatic non-metallic retro reflective sheeting on each side conforming with IRC 67:2012 and meeting the coefficient of retro reflection values as per ASTM D 4956 Type XI label specification. The delineator shall have grooves across thelength to make the reflective sheets vandal- proof. each 5.00 990.00 7 8 9a 9b 10 Road 12M ROW Sr. No. MP PWD Road & Bridge SOR 2022, MPPWD Building Description of Item Unit Qty Rate 8.30 Retro- reflectorised Traffic signs Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign board as per IRC 67-2012 made of high intensity Micro-Prismatic Grade Sheeting (Type IV) vide IRC: 67:2012 clause 6.7.3.2 and clause 801.3.3 of MoRT &H fixed over Aluminum composite material sheet with thermoplastic core of Low density polyethylene (LDPE) between two thick skins/sheets of aluminum with overall thickness of 4mm and aluminum skin of thickness 0.3 on both side, the ACM shall conform to Table 6.1 of IRC:67:2012 and Table 800-1 of MoRT &H specification and High Intensity Micro Prismatic Grade Sheeting shall conform to Table 6.6 of IRC:67:2012 and Table 800-3 of MoRT &H specification of in the clause IRC 6.8 of the IRC 67-2012 and clause 801.3.7 of MORTH message legend numerical letter etc. and borders shall be screen printed on high intensity micro prismatic sheeting shall conform to clause 801.3.7 with digital printing ink or of cutout from transparent durable overlay or cutout from the same type of reflecting sheeting for cautionary/ mandatory/ signs, supported on MS sign post of size 75mm x75mm x 6mm of 3.60 meter over all length and fix to ground by means of properly designed foundation of dimension 450x450x600mm with M20 grade concrete. The ACM sheet shall be fixed to the post with four minimum four number breakaway bolts. & supported with a back support frame of 25mmx25mmx3mm angle. 7 years warranty for Retro Reflection Sheeting to be provided from the original sheeting manufacture as per clause 6.9 of IRC: 67:2012 & a certified copy for three years for outdoor exposure report from an independent test lab as per clause 6.7 of IRC: 67:2012 for the product offered shall be submitted by the contractor.Note:- Manufacture name and date of manufacture is to be printed (Embossed) at the backside of the board. i) 90 cm equilateral triangle each 2.00 4,184.00 13 8.7 Direction and Place Identification signs upto 0.9 sqm size board. Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign board as per IRC 67-2012 made of high intensity Micro-Prismatic Grade Sheeting (Type IV) vide IRC: 67:2012 clause 6.7.3.2 and clause 801.3.3 of MoRT&H fixed over Aluminum composite material sheet with thermoplastic core of Low density polyethylene (LDPE) between two thick skins/sheets of aluminum with overall thickness of 4mm and aluminum skin of thickness 0.3 on both side, the ACM shall conform to Table 6.1 of IRC:67:2012 and Table 800-1 of MoRT&H specification and High Intensity Micro Prismatic Grade Sheeting shall conform to Table 6.6 of IRC:67:2012 and Table 800-3 of MoRT&H specification of in the clause IRC 6.8 of the IRC 67-2012 and clause 801.3.7 of MORTH message legend numerical letter etc. and borders shall be screen printed on high intensity micro prismatic sheeting shall conform to clause 801.3.7 sqm 1.80 6,479.00 with digital printing ink or of cutout from transparent durable overlay or cutout from the same type of reflecting sheeting for cautionary/ mandatory/ signs, supported on MS sign post of size 75mm x75mm x 6mm of 3.60 meter over all length and fix to ground by means of properly designed foundation of dimension 450x450x600mm with M20 grade concrete. The ACM sheet shall be fixed to the post with four minimum four number breakaway bolts. & supported with a back support frame of 25mm x 25 mm x 3mm angle. 7 years warranty for Retro Reflection Sheeting to be provided from the original sheeting manufacture as per clause 6.9 of IRC: 67:2012 & a certified copy for three years for outdoor exposure report from an independent test lab as per clause 6.7 of IRC: 67:2012 for the product offered shall be submitted by the contractor. Note:- Manufacture name and date of manufacture is to be printed (Embossed) at the backside of the board. 6.15 Providing and laying of a reinforced cement concrete pipe NP4 pipes for service ducts below cement concrete pavement (i) (i) 300 mm dia meter 12.00 713.00 12 14 Bituminous concrete Sr. No. SOR Item No. Particulars Unit Quantity Rate (Rs.) 1 5.2 Providing and applying tack coat with catonic bitumen emulsion using emulsion pressure distributor on the prepared bituminous/granular surface cleaned with mechanical broom and as per relevant clauses of section-503 of specifications ii 0.30 kg per sqm (dry & hungry bituminous surfaces /granular surfaces treated with primer) 1500.00 Sqm 1500.00 16 2 5.6 Bituminous Concrete Providing and laying bituminous concrete using crushed aggregates of specified grading, premixed with bituminous binder @ 5.4 to 5.6 % by weight of total mix of mix and filler, transporting the hot mix to work site, laying with a Electronic Sensor paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per clause 507 of specification. b Using Drum Mix Plant of appropriate capacity v for Grading-II ( 30-45 mm thickness ) Bitumen Content minimum 5.4% with 60/70 bitumen(VG-30) 60.00 Cum 60.00 9482 3 8.25 Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beeds on Bituminous surface. Providing and applying (Cleaning of Bituminous surface) thermoplastic compound having composition of binder (Regin) minimum 18 %, titanium dioxide minimum 10 % and intermixed glass beed, minimum 30% of brand like Asian, Burger or equivalent make of 2.5 mm thick including drop down reflectorizing, glass beeds @ 250 gms per sqm area thickness of 2.5 mm is exclusive of surface applied glass beeds as per IRC:35.The finished surface to be level, uniform and free from streaks and holes, all complete as per clause 803 of specifications. Note:- The guarantee of Thermoplastic should be minimum 3 Years. . Edge 50.00 Center 12.50 Sqm 62.50 636 4 8.3P45 Retro- reflectorised Traffic signs Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign board as per IRC 67-2012 made of high intensity MicroPrismatic Grade Sheeting (Type IV) vide IRC: 67:2012 clause 6.7.3.2 and clause 801.3.3 of MoRT &H fixed over Aluminum composite material sheet with thermoplastic core of Low density polyethylene (LDPE) between two thick skins/sheets of aluminum with overall thickness of 4mm and aluminum skin of thickness 0.3 on both side, the ACM shall conform to Table 6.1 of IRC:67:2012 and Table 800-1 of MoRT &H specification and High Intensity Micro Prismatic Grade Sheeting shall conform to Table 6.6 of IRC:67:2012 and Table 800-3 of MoRT &H specification of in the clause IRC 6.8 of the IRC 67-2012 and clause 801.3.7 of MORTH message legend numerical letter etc. and borders shall be screen printed on high intensity micro prismatic sheeting shall conform to clause 801.3.7 with digital printing ink or of cutout from transparent durable overlay or cutout from the same type of reflecting sheeting for cautionary/ mandatory/ signs, supported on MS sign post of size 75mm x75mm x 6mm of 3.60 meter over all length and fix to ground by means of properly designed foundation of dimension 450x450x600mm with M20 grade concrete. The ACM sheet shall be fixed to the post with four minimum four number breakaway bolts. & supported with a back support frame of 25mmx25mmx3mm angle. 7 years warranty for Retro Reflection Sheeting to be provided from the original sheeting manufacture as per clause 6.9 of IRC: 67:2012 & a certified copy for three years for outdoor exposure report from an independent test lab as per clause 6.7 of IRC: 67:2012 for the product offered shall be submitted by the contractor. Note:- Manufacture name and date of manufacture is to be printed (Embossed) at the backside of the board. ii 60 cm equilateral triangle Each 5.00 3011 Bituminous Concrete laying over CC Road MPPWD SOR ROAD & BRIDGE WORKS in force from 25-03-2022 Restoration of 1.2 Meter wide dismantaling of CC road for services Construction of Embankment with Material Deposited from Roadway Cutting Construction of embankment with approved materials CBR>7 deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of table 300-1, 300-2 and as per relevent clauses of section-300. CuM 450.00 Total 450.00 60 3.13 Embankment Construction with Material Obtained from Borrow Pits Construction of embankment with approved material having CBR>7 obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-1, 300-2 and as per relevent clauses of section-300. Embankment/ Sub grade CuM 0.00 155 4.12 Crusher Run Macadam Sub Base/Base Course Providing crushed stone aggregate, depositing on a prepared surface by hauling vehicles, spreading and mixing with a motor grader, watering and compacting with a vibratory roller to clause 410 to form a layer of sub-base/Base in accordance to Table No. 400-14, 400-15 and as per clause of section 407 of specifications. (i) For 53 mm maximum size Carriageway CuM 30.00 1,145.00 6.1 Dry lean cement concrete Sub-base Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing as per clause 601 of specification complete in all respect. Carriageway Cum 30.00 2,767.00 6.3 Cement Concrete Pavement Construction of un-reinforced, dowel jointed, plain cement concrete pavement M-40 grade concrete over a prepared sub base with cement, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, admixtures as approved,curing compound, finishing to lines and grades as per drawing as per IRC 15 2011 and as per relevant clauses of section 602 of specifications complete but excluding cost of steel in dowel bar and tie rods etc. Carriageway Cum 90.00 6,103.00 6 6.8 Add extra in Item No.6.3, 6.4, 6.6 & 6.10 above for the cost of steel in dowel bar and tie rod including craddle, laps etc. complete required as per design. 6.8.1 Mild Steel dowel bars 32mm Dia @300 C/c Total MT 0.89 63587.00 6.8.2 Tie Bar 12 mm Dia @ 600 C/c Total MT 0.42 68297.00 Rate Restoration of 1.2 Meter wide dismantaling of CC road for services Sr. No. MP PWD Road & Bridge SOR 2022 Description of Item Unit Qty 6b 1 2 3 4 5 6a Storm Water Network Sl No PHE SOR2023 Item No PARTICULAR UNIT QUANTITY RATE 1 15.6 Earth work in excavation for foundation, trenches for pipes/ cables, drains or in well excavation etc. by mechanical means/ manual means (exceeding 30cm in depth.) including ramming of bottom, dressing of sides disposal of excavated earth including of all lift and lead upto 50m. Disposed earth to be levelled and neatly dressed. 15.6.1 All kinds of soil. pipe line (450 , 600 mm dia) 1600.00 Brick Masonry Chamber @ 20m c/c(450mm dia pipe) 270.00 cum 1870.00 209.00 2 15.6 Earth work in excavation for foundation, trenches for pipes/ cables, drains or in well excavation etc. by mechanical means/ manual means (exceeding 30cm in depth.) including ramming of bottom, dressing of sides disposal of excavated earth including of all lift and lead upto 50m. Disposed earth to be levelled and neatly dressed. 15.6.3 Ordinary rock or soft rock with or without blasting pipe line (450 , 600 mm dia) 1600.00 Brick Masonry Chamber @ 20m c/c(450mm dia pipe) 270.00 cum 1870.00 270.00 3 15.6 Earth work in excavation for foundation, trenches for pipes/ cables, drains or in well excavation etc. by mechanical means/ manual means (exceeding 30cm in depth.) including ramming of bottom, dressing of sides disposal of excavated earth including of all lift and lead upto 50m. Disposed earth to be levelled and neatly dressed. 15.6.4 Hard rock (requiring blasting) pipe line (450 , 600 mm dia) 800.00 Brick Masonry Chamber @ 20m c/c(450mm dia pipe) 168.75 cum 968.75 491.00 4 15.13 Supplying & filling moorum for pipe bedding or over the pipe (including supply of moorum). pipe line (450 , 600 mm dia) 720.00 cum 720.00 649.00 5 28.3 Providing and Laying non-pressure (NP3) RCC socket & spigot pipes with rubber gasket joint including testing of joints. 28.3.6 pipe line 450 mm dia Mtr 2500.00 2512.00 28.3.7 pipe line 600 mm dia Mtr 2500.00 3297.00 CONSTRUCTION OF STORM WATER NETWORK CONSTRUCTION OF STORM WATER NETWORK 29.7 Constructing Brick Masonry Manhole in Cement Mortar 1 :4 (1 cement : 4 fine sand) R.C.C. top slab 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1cement : 3 fine sand) finished with a floating coat of neat cement and making channels in CC 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including finishing the channel to shape, curing etc. (Excavation foot rest and external cement plaster shall be paid for separately) 29.8 Manhole for property (House) connection 29.8.1 Inside size 60x60 cm and 90 cm deep manhole with fixing of ISI marked pre cast RCC manhole cover & frame i/c transportation etc. 600x600 mm size heavy duty. Nos 200.00 8777.00 7 15.37 Steel work in welded built-up section/ framed work, including cutting hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 15.37.2 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works Kg 300.00 101.00 8 4.5 Providing and laying in position including testing following PVC bends suitable for 6, 8 and 10 Kg/Sq. cm. pressure pipes. 4.5.6 200 mm dia Clear Water Transmission Main from Narmada Tapping to Sump & Pumping main from Sump to OHT Earth work in excavation for foundation, trenches for pipes/ cables, drains or in well excavation etc. by mechanical means/ manual means (exceeding 30cm in depth.) including ramming of bottom, dressing of sides disposal of excavated earth including of all lift and lead upto 50m. Disposed earth to be levelled and neatly dressed. 15.6.1 All kinds of soil. 200 mm Dia Cum 818 Sub total 818 209 2 15.6 Earth work in excavation for foundation, trenches for pipes/ cables, drains or in well excavation etc. by mechanical means/ manual means (exceeding 30cm in depth.) including ramming of bottom, dressing of sides disposal of excavated earth including of all lift and lead upto 50m. Disposed earth to be levelled and neatly dressed. 15.6.3 Ordinary rock or soft rock with or without blasting 200 mm Dia Cum 818 Sub total 818 270 3 15.6 Earth work in excavation for foundation, trenches for pipes/ cables, drains or in well excavation etc. by mechanical means/ manual means (exceeding 30cm in depth.) including ramming of bottom, dressing of sides disposal of excavated earth including of all lift and lead upto 50m. Disposed earth to be levelled and neatly dressed. 15.6.4 Hard rock (requiring blasting) 200 mm Dia Cum 921 Sub total 921 491 4 15.13 Supplying & filling moorum for pipe bedding or over the pipe (including supply of moorum). 10 cm will be depth of moorum bedding 200 mm Dia Cum 204.60 Sub total 204.60 649 5 1.3 Providing, laying and jointing including testing following socket & spigot centrifugally cast (Spun) Ductile Iron pressure pipes with inside cement mortar lining (class K-9) conforming to IS 8329/2000 with suitable Rubber Gasket (Push on) joints as per IS:5382/85 200 mm Dia RMT 3300 3202.00 6 14.1 Labour for cutting following Ductile iron pipes of any type and class. per cut 1 295.00 14.1.6 300 mm dia 7 1.11 Providing and Laying including testing Ductile Iron Double Socket 90° Bends conforming to IS:9523/2000 having dimension as per table 15 of IS:9523/2000 in the following nominal diameter/sizes with external bitumen coating and internal cement mortar lining. 1.11.3 200 mm dia No 2 5048.00 8 1.13 Providing and Laying Ductile Iron Double Socket 90° Bends conforming to IS-9523/2000 having dimension as per table 15 of IS9523/2000 in the following nominal diameter/sizes with external bitumen coating and internal cement mortar lining. 1.13.3 200 mm dia No. 7 4698.00 9 1.15 Providing and Laying including testing Ductile Iron Double Socket 45° Bends conforming to IS- 9523/2000 having dimension as per table 16 of IS- 9523/2000 in the following nominal diameter/sizes with external bitumen coating and internal cement mortar lining. 1.15.4 200 mm dia No. 6 3416.00 Measurement & Abstract Sheet Clear Water Transmission Main from Narmada Tapping to Sump & Pumping main from Sump to OHT Clear Water Transmission Main from Narmada Tapping to Sump and OHT Sr. No. MP PHE SOR 2023 Description of Item Unit Qty Rate 10 1.17 Providing and Laying including testing Ductile Iron Double Socket 22.5° Bends conforming to IS- 9523/2000 having dimension as per table 17 of IS- 9523/2000 in the following nominal diameter/sizes with external bitumen coating and internal cement mortar lining. 1.17.4 200 mm dia No. 5 2786.00 11 1.19 Providing and Laying including testing Ductile Iron Double Socket 11.25° bends conforming to IS-9523/2000 having dimension as per table 18 of IS- 9523/2000 in the following nominal diameter/ sizes with external bitumen coating and internal cement mortar lining. 200 mm dia No. 5 2643.00 12 1.41 Providing & fixing of following Ductile iron double flanged sluice valves as per IS :14846-2000 fitted with cap including jointing & testing with cost of jointing material such as bolts, nuts, rubber insertions etc. all complete.P.N 1.6 200 mm dia No 6 34084 13 8.65(a) Providing & fixing following cast iron double flanged single door reflux (non return) valves including jointing & testing with cost of jointing material such as bolts, nuts and rubber insertion all complete as per IS :5312 (Part I) P.N 1.0 8.65(a).6 200 mm dia No 1 12345 14 1.50 Providing & fixing following ductile iron single chamber triple function temper proof air valves, small orifice with screwed end as per IS:14845- 2000 including jointing & testing with cost of jointing material and rubber insertion all complete as per IS:13095-1991.PN1.0 1.50.1 50 mm dia No 6 9630 15 15.66 Construction of Brick masonry valve chamber with 20 cm thick wall in 1:6 C.M. with 12mm thick 1:4 Cement Plaster and base course 10 cm. thick in M-15. Inside Dimensions 110x80x100cm M-20 RCC chamber cover size 130x120cmx10cm including cost of materials, labour, finished with floating coat of neat cement etc. complete. For Air Valve+ Sluice Valve No 13 9345 16 1.21 Providing and Laying including testing Ductile Iron All socket Tees conforming to IS-9523/2000 having dimension as per table 21 of IS9523/2000 in the following nominal diameter/sizes with external bitumen coating and internal cement mortar lining with finishing as per clause 13 of IS-9523/2000. No 1.21.7 200 mm x 100 mm Dia 2 3985 17 15.11 Filling available excavated earth in trenches, plinth sides of foundation in layers not exceeding 20cm. in depth including consolidation of each layer by ramming watering, lead up to 50m and lift up to 1.5m in all kinds of soils Excavated Quantity Cum 2558 Deductions Pipe volume Cum 9.85 Chamber Cum 10.5 For Concrete Cum 0.0 For murum bedding Cum 204.60 Total Filling Quantity Cum 2332.52 47 Clear Water Transmission Main from Narmada Tapping to Sump and OHT Sr. No. MP PHE SOR 2023 Description of Item Unit Qty Rate 18 13.3 Electromagnetic Bulk Flow Meters Supply of Electromagnetic full bore meter complete as per specification including transportation to site, storage, safety, installation, testing, commissioning, making connections with existing pipe line, including excavation at site, cuts in the existing pipe system, dewatering and reinstating the same after completion of installation as per specification and drawings including all taxes. Accuracy of meter + 0.3% of measured value, Flange connection as per AWWA & IS, Liner:Hard Rubber, Fully welded sensor housing complying to IP 68 standard, Electrodes SS 316, Sensor housing SS 304, Cable gland 1/2 NPT, Sensor housing fully welded SS 304 housing with protective Polyurethane paint, Flow Transmitter/ Converter: Microprocessor based, modular design display 2 line back lit LCD for indication of actual flow rate, forward, reverse, sum totalizer, Perfection category: IP 65 Output: One current output (4-20 mA) one scalable pulse output 13.3.6 200 mm dia Distribution Network from OHT - Earth work in excavation for foundation, trenches for pipes/ cables, drains or in well excavation etc. by mechanical means/ manual means (exceeding 30cm in depth.) including ramming of bottom, dressing of sides disposal of excavated earth including of all lift and lead upto 50m. Disposed earth to be levelled and neatly dressed. 15.6.1 All kinds of soil. 100 mm dia DI K-7 pipes Cum 5782 Sub total 5782 209 5 1.1 Providing, laying and jointing including testing following socket & spigot centrifugally cast (Spun) Ductile Iron pressure pipes with inside cement mortar lining (class K-7) conforming to IS 8329/2000 with suitable Rubber Gasket (Push on) joints as per IS:5382/85 100 mm dia DI K-7 pipes RMT 5900 1500.00 6 1.11 Providing and Laying Ductile iron Mechanical joint collar with follower glands conforming to IS-9523/2000 having dimension as per table 24 of IS-9523/2000 in the following nominal diameter/sizes with external bitumen and internal cement mortar lining 1.11.1 For 100 mm dia DI K-7 pipes Each 10 1527.00 7 1.13 Providing and Laying Ductile Iron Double Socket 90° Bends conforming to IS-9523/2000 having dimension as per table 15 of IS9523/2000 in the following nominal diameter/sizes with external bitumen coating and internal cement mortar lining. 1.13.1 For 100 mm dia DI K-7 pipes Each 10 1527.00 8 1.15 Providing and Laying including testing Ductile Iron Double Socket 45° Bends conforming to IS- 9523/2000 having dimension as per table 16 of IS- 9523/2000 in the following nominal diameter/sizes with external bitumen coating and internal cement mortar lining. 1.15.1 100 mm diameter Each 13 1316.00 9 1.17 Providing and Laying including testing Ductile Iron Double Socket 22.5° Bends conforming to IS9523/2000 having dimension as per table 17 of IS9523/2000 in the following nominal diameter/sizes with external bitumen coating and internal cement mortar lining. 1.17.1 100 mm diameter Each 13 1232.00 Distribution Network from OHT WATER SUPPLY | DISTRIBUTION NETWORK FROM OHT Sr. No. MP PHE SOR 2023 Description of Item Unit Qty Rate 10 1.21 Providing and Laying including testing Ductile Iron All socket Tees conforming to IS-9523/2000 having dimension as per table 21 of IS-9523/2000 in the following nominal diameter/sizes with external bitumen coating and internal cement mortar lining with finishing as per clause 13 of IS9523/2000. 150mm x 150mm dia 1.21.1 100 mm x 100 mm Each 10 2104.00 11 1.41 Providing & fixing of following Ductile iron double flanged sluice valves as per IS :14846-2000 fitted with cap including jointing & testing with cost of jointing material such as bolts, nuts, rubber insertions etc. all complete. P.N 1.1 1.41.2 100 mm diameter Each 8 11519 12 1.5 Providing & fixing following ductile iron single chamber triple function temper proof air valves, small orifice with screwed end as per IS:14845-2000 including jointing & testing with cost of jointing material and rubber insertion all complete as per IS:13095-1991.PN1.0 50 mm diameter No 10 9630 13 15.66 Construction of Brick masonry valve chamber with 20 cm thick wall in 1:6 C.M. with 12mm thick 1:4Cement Plaster and base course 10 cm. thick in M-15. Inside Dimensions 110x80x100cm M-20 RCC chamber cover size 130x120cmx10cm including cost of materials, labour, finished with floating coat of neat cement etc. complete. For Air Valve+ Sluice Valve No 8 9345 14 15.11 Filling available excavated earth in trenches, plinth sides of foundation in layers not exceeding 20cm. in depth including consolidation of each layer by ramming watering, lead up to 50m and lift up to 1.5m in all kinds of soils Excavated Quantity Cum 5782 47 WATER SUPPLY | DISTRIBUTION NETWORK FROM OHT Sr. No. MP PHE SOR 2023 Description of Item Unit Qty Rate 15 13.3 Electromagnetic Bulk Flow Meters Supply of Electromagnetic full bore meter complete as per specification including transportation to site, storage, safety, installation, testing, commissioning, making connections with existing pipe line, including excavation at site, cuts in the existing pipe system, dewatering and reinstating the same after completion of installation as per specification and drawings including all taxes. Accuracy of meter + 0.3% of measured value, Flange connection as per AWWA & IS, Liner:Hard Rubber, Fully welded sensor housing complying to IP 68 standard, Electrodes SS 316, Sensor housing SS 304, Cable gland 1/2 NPT, Sensor housing fully welded SS 304 housing with protective Polyurethane paint, Flow Transmitter/ Converter: Microprocessor based, modular design display 2 line back lit LCD for indication of actual flow rate, forward, reverse, sum totalizer, Perfection category: IP 65 Output: One current output (4-20 mA) one scalable pulse output Clear Water Sump - Design, drawing, construction, testing and commissioning of R.C.C. GSR/Sump well of following capacities with all necessary fitting and accessories as mentioned in the relevant chapter of USOR, IS codes and departmental circulars Complete turn key job for following capacities: Over Head Tank Design, drawing, construction, testing and commissioning of RCC Elevated Service Reservoir/ Over Head Tank (ESR/OHT) with all necessary fitting as mentioned in relevant chapter of USOR, IS code and departmental guidelines. Complete turn key job for following capacities with 9/12/15 meterstaging height from GL:- 18.3 15 Mtr. Staging 18.3.15 400 Kilo Litres Each 2 14.17 Providing and installation of automatic water level indicator for supervisory control cum auto on/off of motor pump assembly inclusive of control panel, 500 mtr long 2 core, 4 pair cable for small rural water supply scheme, having source within 500mtr as per approved specification and as directed by Engineer in charge. In case of lesser length of cable, equivalent amount @ Rs 12 /-per meter of short length will be deducted from above rate) Effluent Network Dismantling Of Existing Structures like Culverts, Bridges ,Retaining Wall and Other Structures ComprisingOf Masonary,Cement Concrete, wood work , Steel Work, Including T&P and Scaffolding, whereever necessary, Sorting The dismantled Material, Desposal Of Unserviceable Materialand Stacking The Serviceable Material With All Lifts and LeadsOf 1000metres C Prestressed/ Reinforced Cement Concrete Grade M-25& Above cum 105 1170.00 2 PHE USOR 2023 15.6 Earth work in excavation for foundation, trenches for pipes/ cables, drains or in well excavation etc. by mechanical means/ manual means (exceeding 30cm in depth.) including ramming of bottom, dressing of sides disposal of excavated earth including of all lift and lead upto 50m. Disposed earth to be levelled and neatly dressed. 15.6.1 All kinds of soil. For Pipe Cum 3150 for manhole chambers Cum 420 Sub total 3570 209 3 15.6 Earth work in excavation for foundation, trenches for pipes/ cables, drains or in well excavation etc. by mechanical means/ manual means (exceeding 30cm in depth.) including ramming of bottom, dressing of sides disposal of excavated earth including of all lift and lead upto 50m. Disposed earth to be levelled and neatly dressed. 15.6.3 Ordinary rock or soft rock with or without blasting For RCC Pipe Cum 6615 for manhole chambers Cum 1260 Sub total 7875 270 4 15.6 Earth work in excavation for foundation, trenches for pipes/ cables, drains or in well excavation etc. by mechanical means/ manual means (exceeding 30cm in depth.) including ramming of bottom, dressing of sides disposal of excavated earth including of all lift and lead upto 50m. Disposed earth to be levelled and neatly dressed. 15.6.5 Hard rock (requiring chiseling where blasting prohibited) For Pipe Cum 2205 for manhole chambers Cum 420 2625 722 5 15.13 Supply & Filling with moorum for pipe bedding or over the pipe including supply of moorum 300 mm Dia, RCC NP3 Cum 441.00 Sub Total 441.00 643 6 28.3 Providing and Laying non-pressure (NP3) RCC socket & spigot pipes with rubber gasket joint including testing of joints. 28.3.3 300 mm RMT 6300 1123.00 Effluent Network EFFLUENT NETWORK Sr. No. SOR Details Description of Item Unit Qty Rate 29.13 Constructing Brick Masonry Circular Man Hole 900 mm internal dia at bottom & 560 mm dia at top in cement Mortar 1:4 (1 cement: 4 fine sand), inside Cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 fine sand) finished with a floating coat of neat cement, foundation concrete 20 cm thick in 1:3:6 ( 1 cement : 3 fine sand : 6 graded stone aggregate 40 mm nominal size ) and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement etc. all complete. 29.13.1 For one Manhole 900mm deep with fixing of 560 mm dia ISI marked reinforcement cement concrete cover & frame heavy duty including transportation etc. in cement concrete 1:2:4 all complete. ( Excavation, foot rests & cement plaster at the external surface shall be paid for separately) Each 50 12020.00 7a 29.13.2 Add extra for depth 0.90 to 1.65 mtr. each 15 4808.00 8 29.12 Constructing Brick Masonry Circular Man Hole 1200 mm internal dia at bottom & 560 mm dia at top in cement Mortar 1:4 (1 cement: 4 fine sand), inside Cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 fine sand) finished with a floating coat of neat cement, foundation concrete 20 cm thick in 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement etc. all complete. 29.12.1 For one manhole upto 1650 mm deep with fixing of 560 mm dia ISI marked reinforcement cement concrete cover & frame heavy duty including transportation etc. in cement concrete 1:2:4 all complete. ( Excavation, foot rests & cement plaster at the external surface shall be paid for separately) Each 100 17593.00 29.12.2 Add extra for depth1.65 mtr. to 2.3m each 30 7037.00 29.10 Constructing Brick Masonry Circular Man Hole 1500 mm internal dia at bottom & 560 mm dia at top in cement Mortar 1:4 (1 cement: 4 fine sand), inside Cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 fine sand) finished with a floating coat of neat cement, foundation concrete 20 cm thick in 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cementetc. all complete. 29.10.1 For one manhole upto 2650 mm deep with fixing of 560 mm dia ISI marked reinforcement cement concrete cover & frame heavy duty including transportation etc. in cement concrete 1:2:4 all complete. ( Excavation, foot rests & cement plaster at the external surface shall be paid for separately) Each 60 27395.00 29.11 Extra for depth for circular manholes over item 15.4 29.11.1 Depth 2.65m to 4.25 m each 18 12258.00 29.14 Providing MS foot rests i/c fixing in manhole with 20x20x10cm CC blocks of 1:3:6 (1 cement:3 coarse sand : 6 graded stone aggregate 20mm nominal size ) 29.14.2 With 20mm round bar foot rest each 640 249.00 7 9 10 11 EFFLUENT NETWORK Sr. No. SOR Details Description of Item Unit Qty Rate 12 15.11 Filling available excavated earth in trenches, plinth sides of foundation in layers not exceeding 20cm. in depth including consolidation of each layer by ramming watering, lead up to 50m and lift up to 1.5m in all kinds of soils RECYCLED (TREATED ) WATER DISTRIBUTION FROM STP TO CONSUMER Earth work in excavation for foundation, trenches for pipes/ cables, drains or in well excavation etc. by mechanical means/ manual means (exceeding 30cm in depth.) including ramming of bottom,dressing of sides disposal of excavated earth including of all lift and lead upto 50m. Disposed earth to be levelled and neatly dressed. Cum 15.6.3 Ordinary rock or soft rock with or without blasting 110 mm ∅ HDPE PE-100 6 Kg/cm Cum 1491.00 1491.00 270.00 15.6.5 Hard rock (requiring chiseling where blasting prohibited) 110 mm ∅ HDPE PE-100 6 Kg/cm Cum 127.80 127.80 722.00 Cum 2 16.10 (a) Filling available excavated earth in trenches, plinth sides of foundation in layers not exceeding 20cm. In depth including consolidation of each layer by ramming watering, lead up to 50m and lift up to 1.5m in all kinds of soils Total Excavation 1618.80 110 mm ∅ HDPE PE-100 6 Kg/cm Cu. M. -56.99 Deduct Pipe Volume 1561.81 37.00 3 2.1 Providing, laying, Jointing & field testing of PE pipes made from 100% virgin material (Earlier know as hight Density Polyethylene pipes, PE 100) conforming to IS 4984/ 14151/12786/ 13488 with necessary jointing material like mechanical connector or jointing pipes by heating the ends of pipes with the help of Teflon coated electric mirror/ heater to the required temperature and then mechanically pressing the ends together against each other, to form a monolithic & leak proof joint by thermosetting process. It may be required to be done with Jacks/Hydraulic Jacks/But fusion machine. (50mm & above fusion jointed & below 50mm mechanical jointed) 10Kg/sq.cm 2.1.6 110 mm ∅ HDPE PE-100 Rm 6000.00 493.00 4 2.2 Providing and laying including testing Bend90ْ conforming to IS specifications. 2.2.6 110 mm ∅ HDPE PE-100 Each 8.00 383.00 5 2.3 Providing and laying Bend 45’ confirming to IS specification 2.3.4 110 mm ∅ HDPE PE-100 Each 8.00 455.00 6 2.4 Providing and laying Equal Tee confirming to IS specification 2.4.4 110 mm ∅ HDPE PE-100 Each 5.00 571.00 RECYCLED (TREATED ) WATER DISTRIBUTION FROM STP TO CONSUMER S. No. MP PHE 2023 Particulars Unit RECYCLE WATER NETWORK Qty. Rate S. No. MP PHE 2023 Particulars Unit 7 2.5 Providing and laying Pipe end confirming to IS specification. Pressure 2.5.4 110 mm ∅ HDPE PE-100 Each 2.00 232.00 8 2.7 Providing butt fusion welded joint/ jointing by heating to the ends with the help of Teflon coated electric mirror/heater ends together etc. by thermosetting process to PE- 100 pipe and specials. (6kg, 8kg, 10kg) (50mm & above fusion jointed & below 50mm mechanical jointed) including testing. 2.7.4 110 mm ∅ HDPE PE-100 Each 5.00 164.00 9 8.62 Providing & fixing of following Cast iron double flanged sluice valves as per I.S.:14846-2000 fitted with cast iron cap including jointing & testing with cost of jointing material such as bolts, nuts, rubber insertions etc. all complete PN-1.0 8.62.4 100mm ∅ Each 5.00 5097.00 10 8.67 Providing & fixing following cast iron butterfly valves including jointing & testing with cost of jointing material such as bolts,nuts and rubber insertion all complete as per IS :13095- 1991 CLASS PN-1.0 8.67.4 100 mm Each 3.00 3217.00 11 15.66 Construction of Brick masonry valve chamber with 20 cm thick wall in 1:6 C.M. with 12mm thick 1:4 Cement Plaster and base course 10 cm. thick in M-15. Inside Dimensions 110x80x100cm M-20 RCC chamber cover size 130x120cmx10cm including cost of materials, labour, finished with floating coat of neat cement etc. complete. Each 13.00 9345.00 15.32 Providing & laying mechanically mixed R.C.C. excluding centering & shuttering and reinforcement in foundation/plinth (20mm graded metal) 15.32.1 1:1.5:3 (M 20) CUM 72.00 5916.00 13 16.25(a) Providing and placing in position cold twisted steel and hot rolled deformed steel reinforcement for R.C.C. work i/c cutting, bending, binding etc. complete i/c cost of binding wire and wastage. Sub Structure Kg 432.00 68.00 12 OHT Sr. No. MP PHE SOR 2023 Description of Item Unit Qty Rate 1 18 Design, drawing, construction, testing and commissioning of RCC Elevated Service Reservoir/ Over Head Tank (ESR/OHT) with all necessary fitting as mentioned in relevant chapter of USOR, IS code and departmental guidelines. Complete turn key job for following capacities with 9/12/15 meterstaging height from GL:- 18.3 15 Mtr. Staging 18.3.3 100 Kilo Litres Each 2 14.17 Providing and installation of automatic water level indicator for supervisory control cum auto on/off of motor pump assembly inclusive of control panel, 500 mtr long 2 core, 4 pair cable for small rural water supply scheme, having source within 500mtr as per approved specification and as directed by Engineer in charge. In case of lesser length of cable, equivalent amount @ Rs 12 /-per meter of short length will be deducted from above rate) Each 1 18000 Over Head Tank DISMANTLING WORKS Dismantling of Cement Concrete Pavement Dismantling of cement concrete pavement by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling Serviceable material at designated locations and disposal of unserviceable materials up to a lead of 1000 metres, CUM 100.00 1,283.00 2 2.1 Cutting of Trees, including Cutting of Trunks, Branches and Removal Cutting of trees, including cutting of trunks/branches in suitable size removal of stumps/roots, and stacking of serviceable material with all lifts and up to a lead of 1000 mtrs and filling earth in the depression/pit.. i Girth from 300 mm to 600 mm No 10.00 244.00 3 2.13 Removal of Telephone / Electric Poles and Lines Removal of telephone / Electric poles including excavation and dismantling of foundation concrete and lines under the supervision of concerned department, disposal with all lifts and up to a lead of 1000 metres and stacking the serviceable and unserviceable material separately. Each 10.00 168.00 4 2.3 Dismantling of Structures Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood, steel, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead upto 1000 metres. (i) Lime /Cement Concrete B Cement Concrete Grade M-15 & M-20 Cum 75.00 425.00 (ii) Dismantling Brick / Tile work B In cement mortar Cum 270.00 282.00 15.13 Taking out existing CC interlocking paver blocks from Sqm 750.00 31 11.43.3 UADD BUILDING SOR 2021(AMM ENDMENT) Laying old cement concrete interlocking paver blocks of anydesign/shape laid in required line, level, curvature, colour and pattern over and including 50mm thick compacted bed of sand, filling the joints with sand including cost of paint, eie all complete as per the direction of Engineer-in-charge. Sqm 750.00 142 DISMANTLING WORKS Horticulture S.No SOR Description Unit Quantity Rate 1 MPPWD Building SOR2024 28.1 Trenching in ordinary soil up to a depth of 60cm including removal and stacking of serviceable materials and then disposing of by spreading and neatly levelling with in a lead of 50m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or/and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure). Cum 150 186 2 MPPWD Building SOR2024 28.2 Supplying and stacking of good earth at site including royalty and carriage up to 1 km (earth measured in stacks will be reduced by 20% for payment). Cum 30 511 3 MPPWD Building SOR2024 28.3 Supplying and stacking sludge at site including royalty and carriage up to 1 km (sludge measured in stacks will be reduced by 8% for payment). Cum 3 643 4 MPPWD Building SOR2024 28.9 Mixing earth and sludge or manure in proportion specified or directed. Cum 3 11 5 MPPWD Building SOR2024 28.8 Spreading of sludge, dump manure or/and good earth in required thickness (Cost of sludge, dump manure or/ and good earth to be paid separately). cum 3 16 6 MPPWD Building SOR 2024 28.15 Providing and planting different variety of plants of approved quality and sizes as mentioned including making pits of required size at site, refilled with B.C. Soil mixture manuring and pesticide etc. complete (to be paid separately) including watering and 90 days maintenance from the date of final bill as per direction of Engineer-in-Charge complete in all respect (B.C. Mixture paid separately) 7 MPPWD Building SOR 2024 28.15.1 Bahunia Tomentosa, Beloperone Species, Caselpinnia Pulcherima, Bird of Paradise, Callandra Emarginata, Callandra Hybrida, Cassia Bi flora, Cassia Laevigata, Cestrum Nocturnum, Dombeya Mastersii, Euphorbia Caracasana, Euphorbia Pulcherima, Excorea bi color, Excorea tri color, Ficuas Blackii, Ficus Reginold, Ficus Panda, Gardenia, Gulphinia, Jasminoides, Hamelia Pattens, Heliconia, Hibiscus Rosasinensis, Hibiscus Verigated, Hibiscus Viceroy, Jatropha Multifida, Largestomia Indica, Malpighia Coccigera, Murraya Exotica, Murraya Koeniggi, Murraya Sambucum, Mussaenda Erythrophylla, Nerium Oleander, Nyctanthus Arbortristis, Plumbego Capensis, Putranjeeva Roxburghii, Tabernaemontana Coronaria, Tabernaemontana Divaricata, Tecoma Gaudi Chaudi, Tecoma Stans, Thevetia Nerifolia, Thuja Compacta and equivalent plants Nos 232.00 80.00 8 MPPWD Building SOR 2024 28.15 Providing and planting different variety of plants of approved quality and sizes as mentioned including making pits of required size at site, refilled with B.C. Soil mixture manuring and pesticide etc. complete (to be paid separately) including watering and 90 days maintenance from the date of final bill as per direction of Engineer-in-Charge complete in all respect (B.C. Mixture paid separately). Horticulture Bahunia Tomentosa, Beloperone Species, Caselpinnia Pulcherima, Bird of Paradise, Callandra Emarginata, Callandra Hybrida, Cassia Bi flora, Cassia Laevigata, Cestrum Nocturnum, Dombeya Mastersii, Euphorbia Caracasana, Euphorbia Pulcherima, Excorea bi color, Excorea tri color, Ficuas Blackii, Ficus Reginold, Ficus Panda, Gardenia, Gulphinia, Jasminoides, Hamelia Pattens, Heliconia, Hibiscus Rosasinensis, Hibiscus Verigated, Hibiscus Viceroy, Jatropha Multifida, Largestomia Indica, Malpighia Coccigera, Murraya Exotica, Murraya Koeniggi, Murraya Sambucum, Mussaenda Erythrophylla, Nerium Oleander, Nyctanthus Arbortristis, Plumbego Capensis, Putranjeeva Roxburghii, Tabernaemontana Coronaria, Tabernaemontana Divaricata, Tecoma Gaudi Chaudi, Tecoma Stans, Thevetia Nerifolia, Thuja Compacta and equivalent plants. EACH 2000 80.00 8b MPPWD Building SOR 2024 28.15.5 Alpinia Verigated, Alternanthera species, Aspyragus Myerri, Aspyragus Springenii, Aspidistra, Canna (regular, Dwarf), Chlorodendron Inermii, Chlorophytum (Green), Chlorophytum verigated, Coffea Chinensis, Dianella Verigated, Durranta (Goldiana, Green, Verigated), Euphorbia Milli hybrid, Ipomea (Golden leaves), Iresine herbstii, Juniper Prostata, Juniper Africana, Ophiopogon plant, Ophiopogon jaburan, Portulacaria Afra (jade Plant), Schefflera Green, Schefflera verigated, Setcreasea Purpurea, Syngonium (Butterfly) species, Syngonium miniature, Syngonium Dwarf, Syngonium variegated, Tradescantia, Wadelia Trilobata, Zebrina Tradescantia, Pendanas, Spider Lily Black, Spider Lily verigated, Aclypha (Red, Green,Mini), Lantana (Red, Yellow, Purple, White, verigated), Haemalia Mini and similar plants. 100 KVA TRANSFORMER WITH DP STRUCTURE ITEM BASED ON MPPWD S0R 2024 1 37.9 Supply and laying 25mm X 5mm G.I. strip at 0.5 metre below ground level as strip earth electrode including jointing etc. as required. Metre 30 130 2 37.17 Providing and fixing 4.0mm (8 SWG) dia G.I. wire on surface or in recessed for loop earthing as required Metre 10 30 3 37.40 Supply and erection of approved make safe earthing electrode consisting pipe-in- pipe technology as per IS 3043-1987 made of corrosion free G.I. pipes with constant ohmic value surrounded by highly conductive compound with high charge dissipation suitable for effective and maintenance free earthing in earth pit of minimum bore dia. 150mm size, as mentioned below : 37.40.2 With 3 metre G.I. pipes having outer pipe dia of 50mm having 80-200 micron galvanizing, Inner pipe dia. of 25mm having 200-250 Micron galvanizing, connection terminal dia. of 12mm in nominal soil with 50 kg (two bag) back filling bentonite compound UL listed and confirm to relevant International/Indian standards around electrode upto ground level. Each 6 13140 7 41.12 Supplying & installing G.I. pipe for protection of underground cable fixed on wall/support/in trench/fixed between two rigid existing support of wall/beam for erection of ceiling Fan/down rod for stiff pendent for light luminaries /fan/protective for earthing, lightening conductor down strip/overhead service line/for submersible cable or centrifugal pump for water supply with necessary iron clamp coupler, bend, tee, elbow, nuts and bolts etc. complete in an approved manner as required to complete excluding cost of excavation/dismantling & other finished masonry Item complete. 41.12.1 For B class pipe ISI marked (IS-1161-68) 41.12.1.6 50.00mm Metre 30 550 42.70 Supplying, installing, testing and commissioning of 11/0.4 KV 3 Phase 50 cycle oil immersed, naturally cooled, outdoor type transformer connected delta on H.T. side and star on L.T. side, dehydrating silica gel breather on eye level, rating and diagram plate, two earthing terminal, lifting lugs, oil level gauge, drain valve with plug, temperature not exceeding 50ºC on load, oil filling hole with plug, four unidirectional roller, arcing horns, explosion vent, terminal arrangement bushing on H.V. side and cable box on LV side, first filling of oil upto desired level and transformer installing on existing structure with all required materials arrangement as required ISI marked & as per IS specification, hand operated off load tap changer switch above 100 KVA, oil conservator with drain valve, plug 63 KVA and above. 42.70.3 Aluminium wound 42.70.3.3 100 KVA Each 1 348160 100 KVA TRANSFORMER WITH DP STRUCTURE S. No. Sub Item No. Description of Item Unit Qty Rate (in Rs) 100 KVA TRANSFORMER WITH DP STRUCTURE S. No. Sub Item No. Description of Item Unit Qty Rate (in Rs) 42.2 Supply of support for overhead line RS joist of I.S. standard including drilling of required hole etc. complete as required. 42.2.6 H - Beam 152x152mm, Std weight 37.1 Kg/Mtr Mtr. 104 2843 42.58 Supplying and erection of single piece nonlinear resistor type lighting arrestor (set of 3 nos) for 3 wire, 11KV overhead lines/sub-station with rated voltage of 9KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanized clamping arrangement, G.I. bolts, nuts, washer etc. as required. Set 1 3832 42.63 Supplying installing, testing & commissioning D.O. fuse assembly with brass part contact for 33 or 11/0.4 KV DP Structure set of 3 Nos. with fuse barrel i/c required fuse element & other materials as per specification on existing D.P. structure as required. 42.63.1 11KV Set 1 4721 42.44 Supplying and erection of 11KV porcelain pin insulator complete with long steel head G.I. pin, nut, washer etc. as required. Each 12 375 42.45 Supplying and erection of 11KV porcelain disc insulator for 11KV overhead lines with galvanized insulator fittings, ball and socket type, and complete with galvanized strain clamp, bolts, nuts washer etc. as required Each 6 750 17 29.27 Supply, fixing, testing & commissioning wall/floor mounted LT panel primer coated with powder coated paint & provided with required gasket for dust/vermin proof with degree of protection IP42 suitable for 415Volt 3 phase, 50 Hz, 4 wire system fabricated out of CRCA sheet upto 2 mm thick (1.6 mm for doors) duly compartmentalized for incomer, bus section, outgoings, cable alleys & CT, PT Ampere Metre, Volt Metre, selector switches, frequency Metre, phase indicating lamp, Energy Metre complete including cost of busbar supports, detachable cable gland plates, 2 earthing terminals, internal wiring & fixing of separately supplied MCBs, MCCBs, ACB, panel mounted changeover switch/SFUs, etc. as required but excluding cost of busbar strips, Ampere Metre, Volt Metre, selector switch as per approved design & specification kg. 250 397 18 29.28 Supply and fixing of LT panel accessories of approved make in existing LT panel including connections etc. as required as per specification. 29.28.6 Aluminium bus bar strips with PVC sleeves kg 25 284 29.28.6 LED lamp indicator Each 3 255 20 42.68 Supply, laying and fixing of G.I. earth coil of 4mm dia G.I. wire having 120 turns of nearly 50mm dia. and 3 mt. long tail in existing pit duly earthed with pole etc complete as required as per specification. Each 5 293 21 42.69 Supplying and fixing 33/11/0.4 KV enamel coated danger board size 200x250mm with clamp on existing HT/LT structure/poles. Each 1 205 100 KVA TRANSFORMER WITH DP STRUCTURE S. No. Sub Item No. Description of Item Unit Qty Rate (in Rs) 42.5 Supplying and drawing all aluminium alloy conductor (AAAC) of approved make conforming to IS 398-1979 Pt. IV, including binding at existing insulator, jointing, jumpering, tearing off, connecting etc. as required including clearing of obstacles (if any) 42.5.4 AAAC 0.1 sq inch (100 sq.mm Al. EQ.)- (Dog) Km. 0.5 104339 27.1 Supply of ISI marked and approved make of moulded case circuit breaker (MCCB) suitable for 3 phase,3 pole, 50 Hz, 415 Volts, AC supply with respective interrupting capacity (KA) at 415 Volts cited against their range standard conforming to IS – 8828 27.1.10 MCCB 36kA current rating, 3P -315Amp &adjustable: 80% -100% thermal Each 1 23636 27.1.4 MCCB 25kA current rating, 3P -125Amp & 80% -100% adjustable Each 3 9953 41.1 Supply of XLPE insulated power cable (conforming IS-7098 Part-I) 1100 Volt grade, 1 core/2 core/3½ core/4 core ISI marked with alu. stranded /solid conductor 41.1.1 Unarmoured 1 core 41.1.1.5 70 sq. mm. Metre 12 143 42.42 Supply, fabrication and erection of angle/channel/flat iron fitting for overhead line & sub-station etc such as D bracket, cross arms, top clamp, V cross arms, back/support clamp or other similar work etc. including nut bolts of required size, making holes, fabrication, welding, cutting, etc. and painting with one coat of red oxide paint & two coat of aluminium paint as required as per specification. Kg 250 105 42.116 Supply, installation, testing & commissioning of LT trivector energy meter, DLMS compliant category-A (for substation/feeder metering) , 3 phase 4 wire, 440 Volts, 5 Amp, accuracy class 0.5S with GSM(GPRS compatible) modem suitable for required C.T. 5A duly tested from electricity board with uPVC box . Each 1 14882 41.7 Supplying and fixing crimping type alum. lugs as per I.S.S. specification suitable for following size of cable with alu./copper solid/stranded conductor evenly crimped with high/pressure tool and connected to switch gear/bus/M.C.C.B./M.C.B. etc. as required complete. 41.7.5 70 sq. mm Each 6 35 42.78 Supply of hand gloves 11KV tested Set 1 1077 42.81 Supply of fiber D.O operating rod for 11/33KV tested Each 1 3854 42.82 Supply of first aid box complete with medicine & bandage as per specification. Each 1 1646 42.83 Supply of shock instruction chart duly framed with glass, as reqd. Each 1 537 ROAD LIGHTING WORK S. N. MPPWD SOR 2024 Description Unit Quantity Rate 1 27.8 Supply of ISI marked and accepted standard of miniature circuit breaker (MCB) of C series with short circuit indication, suitable for 240/415 Volts,50 Cycle, 10 kA/15 kA Value AC supply conforming to IS : 8828 : 1996, IEC : 60898 :2002 & 60947-2 but without enclosures : A 27.8.1 SINGLE POLE (SP) B 27.8.1.2 6 Amp to 32 Amp Rating 10 kA Each 120 263 2 28.4 Fixing of MCB /MCCB/ Isolator in sheet steel enclosure as required as per accepted practice, including mounting on busbar and cable connection etc. complete (Labour only ) 28.4.1 MCB / Isolator SP/DP Each 120 22 3 29.6 Supplying and fixing of multi core round HRFR / FR PVC insulated copper (flexible) conductor & PVC sheathed cables 1100 Volts as per IS:694-1990 of approved make A 29.6.3 ( 30 /0.25 mm ) Three core 1.5 sq.mm. Metre 2200 50 4 31.27 Supply & Fixing of Decorative LED Street Light of 1 to 3 watt with each , system lumens output with Efficacy>=135Im/W(@6500k), Its body made of Die cast aluminium using pressure die-casting process. Hole for coupling on pipes dia 60 mm. for lateral installation. Silicon gasket enusures the IP protection. IP Rating - IP66. Power LED Module with high efficacy LEDs on single Printed Circuit Board with metal core plate. Colour Rendering Index: Ra > 70. Electronic Power Supply for LED Module, which offers Protection against Short Circuit, Over- Voltage & OverCurrent. with in-built surge protection upto 4kv (an additional surge protection device of 10kV also provided in-built the fixture). PF>0.95 and THD<10%. Lens cover in PC (IK09). Estimated LED Lifetime is L70 @ 1,00,000 hours minimum. LM79-80 report from LED manufaturer should be submitted. Safety test report as per IEC 60598-2- 3;IEC 60598-1 / IS 10322 IEC 61347 i/c connection wire . testing etc-Supporting Test Report from NABL approved lab, with 5 year on site warranty. A 31.27.3 80/90W color temp 3000-6500k as required Each 110 14113 5 37.35.2 Providing and fixing earthing arrangement with 38.1mm dia2.5 metre long galvanized iron pipe electrode including packing of charcoal powder and salt as per specification watering pipe 19mm dia G.I. Connection, cover plate having locking arrangement on the top etc. complete with refilling the pit as required, including excavation of earth pit in soil / soft rock Each 20 3670 6 37.16 Providing and fixing 25mm X 4mm G.I. strip on surface or in recessed/concealed for connection etc. as required. Metre 30 130 7 42.68 Supply, laying and fixing of G.I. earth coil of 4mm dia G.I.wire having 120 turns of nearly 50mm dia. and 3 mt. Long tail in existing pit duly earthed with pole etc complete as required as per specification. Each 110 293 8 41.14 Supplying and installing Double wall corrugated pipes of HDPE ( IS 14930 Part II - marked ) for cable laid under ground with necessary material and at required depth upto 90cm. below road/ground surface, including excavation in all type soil & rock, back filling with excavated aterial, ramming and making the surface good. A 41.14.1 50.00mm outside dia. Metre 3700 133 9 41.1 Supply of XLPE Insulated power cable (confirming IS-7098 Part-I ) 1100 Volt grade, 1 core /2 core /3½ core/4 core ISI MARKED with Alu. Stranded /solid conductor 41.1.10 4 CORE ARMOURED A 41.1.10.3 16 Sq.mm Metre 3700 218 41.1.8 3½ CORE ARMOURED B 41.1.8.3 50 Sq.mm Metre 500 373 10 41.5 Supplying and fixing heavy duty cable gland for P.V.C. insulated armoured cable with brass washer, Rubber ring complete erected with cable and lead connection etc. as per specification complete A 41.5.1.3 Gland size 28mm for 3/4 X16 Sq.mm Each 246 138 B 41.5.1.4 Gland size 32 mm for 2/3, 3½, 4 x 25 sq.mm OR 2/3, 3½ x 35 sq. mm or 2/3/3½ x50 sq. mm. Each 10 158 11 41.6 Supplying and fixing ferrules as per IS - specification suitable for following size of cable for circuit identification including connection as required complete A 41.6.3 16.000 Sq mm Each 984 4 ROAD LIGHTINNG WORK 50.00 Sq.mm Each 40 11 12 41.7 Supplying and fixing cramping type Alum. lugs as per I.S.S. Specification suitable for following size of cable with Alu. /Copper solid/stranded conductor evently cramped with high/pressure tool and connected to switch gear/Bus/M.C.C.B./ M.C.B. etc. as required complete A 41.7.1 6 Sq.mm to 16.000 Sq mm Each 984 8 B 41.7.4 50 Sq.mm Each 40 22 13 41.15 Laying of one number armoured / unarmoured power cable 1.1kV grade of size not exceeding 25 Sq.mm direct in ground including excavation in all soil / murrum / soft rock, sand cushioining, protective covering and refilling the pit etc. as required. Metre 3700 230 14 41.15.7 Laying of one number armoured / unarmoured power cable 1:1 kV grade of size not exceeding 25 Sq.mm in the existing RCC Hume/Stone ware/G.I. pipe / DWC Pipe on surface in existing trench as required Metre 3700 28 15 41.15.32 Laying of one number armoured / unarmoured cable1.1kV grade of size exceeding 25 Sq.mm but not exceeding 120 Sq.mm on surface in existing trench etc.as required. Metre 500 33 16 42.98 Providing and erection of hot dipped galvanized octagonal poles in single section made from 3mm thick sheet having lockable weather proof flush door junction box, suitable size & type of foundation bolts 4 nos. J type (EN8 grade) complete, erected in an approved manner on provided foundation. A 42.98.7 9 meter height, 155 X 70mm A/F, 250x250x16mm base plate having weight 87 kg ± 3%, 4 nos. X 24 x 750mm bolt having weight 12 kg ± 3%. Each 110 15447 17 42.107 Providing and fixing of sword canopy type double arm GI bracket upto 2 Mtr. Long for 70mm A/F top octagonal pole Each 0 1573 18 42.100 Providing and fixing of sword canopy type single arm GI bracket upto 2 Mtr. Long for 70mm A/F top octagonal pole Each 110 1658 19 42.111 Designing and construction of footing foundation for octagonal pole of desired size including excavation in soil/soft rock, base concrete M-7.5 (1:4:8), 15mm thick and pedestal of RCC M-20 (1:1.5:3), required tor steel reinforcement for required size from base concrete, shuttering, curing etc. with existing foundation bolts complete as per specifications in an approved manner as per manufacturer drawing or engineer-incharge. P. Cum 26.73 6770 TOTAL FOR SOR ITEMS NON SOR ITEMS Supply of street light control panel for operating street light including MCCB contractors and others necessary items as per specification compelete dully painted with all norms at indutrial area for Textile park Jaora A) contractor- 40 Amp L & T B) Mccb-100 Amp L&T/ CG C) MCCB- 63 Amp Acio-Mefa D) Timer Standarad E) Cut out 100Amp F) Connecting Strip G) Bus Bar Installation of street light control Panel including excavation refilling with C:C 1:3:6 foundation and connection with required lugs existing pole/ MPEB Pole 21 NON SOR Each 5 75000 ETP Sl No Description Unit Rate Quantity A Survey , Investigation Design, Construction, Supply, Erection, Testing Commissioning of proposed Effluent Treatment Plant of Capacity 250 KLD expandable upto 500 KLD based on MBR process with 100% ZLD concept as per norms of CPBC/MOEF/MPPCB including one no Intermediate Effluent pumping stations along with complete infrastructure, campus boundary, campus development , utilities, inhouse laboratories, all necessary Civil, Piping, Mechanical, DG set and Electrical & Instrumentation works complete including 3 months trial run and Five Years Operation &Maintenance of complete facility after successful commissioning on turnkey basis. Plant shall be fully automated. (Rates to be quoted including consultancy cost of all necessrry permissions as mentioned in bid document, Operation & maintenanace and cost with all material & Manpower etc. Complete.) Lumsum 50000000 1 EFFLUENT TREATMENT PLANT(MBR PROCESS) -250 KLD EXPANDABLE UPTO 500 KLD ON ZLD CONCEPT
Contract Date : 07 Aug, 2025   |   Contract Value : 11.15 Crore
BRR : 7636241 Tender For Provision Of Cgsd (Kochi) At Willingdon Island, Kochi; 1 SCHEDULE A Part - I (BUILDING & STRUCTURE WORKS)Details of prepriced schedule is given in tender documents. 2 SCHEDULE A PART-II ( SITE CLEARENCE/DEVELOPMENT & EARTH WORKS) Details of prepriced Schedule is given in tender documents. 3 SCHEDULE A PART-III (INTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents. 4 SCHEDULE A PART-IV (INTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents. 5 SCHEDULE A PART-V (FIRE FIGHTING)Details of prepriced Schedule is given in tender documents. 6 SCHEDULE A PART-VI (ROAD/PATH/ HARD STANDING/CULVERT)Details of prepriced Schedule is given in tender documents. 7 SCHEDULE A PART-VII (EXTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents. 8 SCHEDULE A PART-VIII (EXTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents. 9 SCHEDULE A PART-IX (SEWAGE DISPOSAL) Details of prepriced Schedule is given in tender documents. 10 SCHEDULE A PART-X (AREA DRAINAGE) Details of prepriced Schedule is given in tender documents. 11 SCHEDULE A PART-XI (COMPOUND WALL) Details of prepriced Schedule is given in tender documents. 12 SCHEDULE A PART-XII (ORGANIC WASTE CONVERTER AND SMART ENERGY METER) Details of prepriced Schedule is given in tender documents. 13 SCHEDULE A PART -XIII (MISCELLANIOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as Rs 0.00 under Col. E signifies this fact only. 14 INTERNAL WATER SUPPLY S & F for 15 mm dia bore CP two way bib cock with CP wall flange (Make : Jaquar Model No. OPP15041PM / Eqvlt in Kohler/Grohe), cast copper alloy, screwed down high pressure with crutch screwed both ends for CPVC pipes or for union and fixed complete all as specified and directed by Engr-in-charge. 15 S & F for 15 mm dia bore CP bib cock with CP wall flange (Make : Jaquar Model No. OPP15037PM / Eqvlt in Kohler/Grohe), cast copper alloy, screwed down high pressure with crutch, screwed both ends for CPVC pipes or for union and fixed complete all as specified and directed by Engr-in-charge. 16 S & F for 20 mm bore concealed Stop cock reqular brass body with spindle extnwith Exposed Part Kit of Concealed Stop Cock with Fitting Sleeve, Operating Lever & Adjustable Wall Flange (Compatible with ALD-083CQT & ALD-089CQT)(Make : Jaquar Model No. ALD 089 CQT/ Eqvlt in Kohler/Grohe), cast copper alloy, screwed down high pressure with crutch , screwed both ends for CPVC pipes or for union and fixed complete all as specified and directed by Engr-in-charge. 17 S & F for 25 mm dia bore concealed Stop cock reqular brass body with spindle extn with Flush Cock & Wall Flange 25mm Ceramic Disc Cartridge) with Plain Knob (Make : Jaquar Model No. ALD 081/ Eqvlt in Kohler/Grohe), cast copper alloy, screwed down high pressure with crutch, screwed both ends for CPVC pipes or for union and fixed complete all as specified and directed by Engr-in-charge. 18 S & F 20mm bore CP angular stop cock with CP wall flange (Make : Jaquar Model No. CQT 23053 / Eqvlt in Kohler/Grohe), cast copper alloy, screwed down, high pressure with crutch, screwed both ends for iron pipe or for union and fixed 19 S & F for 100 mm overhead shower rose round shape single flow (ABS Body chrome plated with gray face plate (Make : Jaquar Model No. 1989 with SHA 479L300S / Eqvlt in Kohler/ ESS ESS) with Shower Arm ø20mm & 300mm Long Round Shape with 90˚ Bend for Wall Mounted Showers with Stainless Steel connected to pipe complete all as specified and directed by Engr-in-charge. 20 COOLING APPLIANCESDesign, Supply, Installation, Testing and Commissioning of Invertor Type Floor Mounted Packaged AC Units of specified capacities, combination of energy efficient Inverter compressor plus fixed compressors, nominal capacity condensing unit with all standard fittings, safety devices, like HP/LP cutout, single phase preventor, overload relays, R-410A Gas, vibration isolation pads etc. Suitable to work till 50 Deg ambient, Blue Fin Condensor and Corrosion Resistant Body, Wide Voltage Range 360V - 440V, The quoted rate shall include Group controller also asrequired for controlling AC from a single point and timer option for load sharing of AC units complete all as specified and as directed by Engineer - in - charge, of following capacities.Note: Design report shall be submitted before execution of work at site by the contractor to GE for his scruitiny/comments and further submitted to AO for his approval.Make: Blue Star/Daikin/Haeir/Godrej/Voltas/Equivalent. (HIGH SIDE (MACHINES))(Outdoor unit) 21 a) 22 TR Inverter Package AC Units 22 b) 16.5 TR Inverter Package AC Unit 23 Design, Supply, Installation, Testing and Commissioning of Normal Type Floor Mounted Packaged AC Units of specified capacities, nominal capacity condensing unit with all standard fittings, safety devices, like HP/LP cutout, single phase preventor, overload relays, R-410A Gas, vibration isolation pads etc. Suitable to work till 50 Deg ambient, Blue Fin Condensor and Corrosion Resistant Body, Wide Voltage Range 360V - 440V, The quoted rate shall include support works for outdoor units with necessary catwalk for service access complete all as specified and as directed by Engineer - in - charge, of following capacitiesNote: Design report shall be submitted before execution of work at site by the contractor to GE for his scruitiny/comments and further submitted to AO for his approval.Make: Blue Star/Daikin/Haeir/Godrej/Voltas/Equivalent. LOW SIDE (MACHINES))(Indoor unit) 24 a) 22 TR Inverter Package AC Units 25 b) 16.5 TR Inverter Package AC Unit 26 Supply, Installation and Testing of Refrigerant pipingwith necessary clamping (suction & Discharge) Hard/Soft drawn Copper tube of suitable sizes, with copper elbows, tees, Tubular Nitrile Insulations etc as required complete all as specified and as directed by Engineer - in - charge. 27 S & F Control Cabling B/W Indoor & Outdoor units 28 M & L Refrigerant Gas - R410A 29 Supply, Installation and Testing of Hard PVC drain piping. Drain piping with Tubular Nitrile Rubber Insulation: complete in all respects, well clamped till drain Points complete all as specified and as directed by Engineer - in - charge. For All Units 30 DUCTINGSupply, fabrication, installation, testing of GI rectangular ducts, complete with all fittings such as tee, bends, special off shoots, inspection doors, transformation pieces etc. as required as per IS 655 including suspension and supporting arrangement for plenum, duct etc. required complete all as specified and as directed by Engineer - in - charge. 31 a) Using 0.63 mm (24 Gauge) GI sheet 32 b) Using 0.80 mm (22 Gauge) GI sheet 33 c) Using 1.00 mm (20 Gauge) GI sheet 34 DUCT INSULATION & LININGSupply and Installation of Acoustic Insulation of ducts using 9MM Open Cell Nitrile Rubber, well adhesived, 150 - 180 Kg/cm2 complete all as specified and as directed by Engineer - in - charge. 35 Supply, installation & testing of Thermal Insulation of ducts using 9MM Closed Cell Nitrile Rubber, well adhesived, 40-60 Kg/cm2 complete all as specified and as directed by Engineer - in - charge. 36 S & F Canvas Connection 37 AIR DISTRIBUTION PRODUCTSSupply and Fixing of Powder Coated Aluminium Grills/ Diffusers (Supply/ Return) complete all as specified and as directed by Engineer - in - charge. 38 S & F Collar Dampers 39 Supply and Installation of Fire Dampers complete all as specified and as directed by Engineer - in - charge. 40 Supply, Installation, Testing and Commissioning of Heater Bank Plus Humidistat Arrangement complete all as specified and as directed by Engineer - in - charge. 41 Supply and fixing, testing and commissioning water coolerhaving stainless steel body with inbuild purifier HIMA 7 NHC, dispencing capacity 125 ltr/hr and storage tank capacity 40 ltr normal and 40 cold electric driven (single phase), 230 volt, AC power supply with all connecting accessories complete all as specified and directed. 42 Supply and fixrefrigerator, electric driven (single phase), 220 V,50 HZ, capacity 195 Litres, 3 Star rated direct cool inverter, single door all as specified and directed by the Engineer-in-Charge. 43 Supply and install, testing and commissioning of split type air conditioner 1.5 TR Capacity of invertertechnology 5 star rating with cordless remote control single phase 240 volts complete with all accessories such as indoor and outdoor units and refrigerent tubing of adequete length as required at site indoor mounting plate, duly powder coated fixing with anchor bolts at any height, drain pipe of suitable size brought to ground level from any height, initial filling of refrigerent gas including making round hole on existing wall for taking up refrigerent tubing, drain pipe, cables, etc and making good the disturbed surface by matching with existing adjoining surface complete all as specified and directed (Cooling appliances- qty 4, Air conditioning- qty 10) 44 Supply and fix Voltage stabilizer 3 KVA for automatic operation, single phase naturally air cooled indoor type, wall mounted & designed for input variation between 170 V to 280 V with output voltage stabilized at 230 V with accuracy of ± 2.5% 45 Supply and fix Voltage stabilizer 4 KVA for automatic operation, single phase naturally air cooled indoor type, wall mounted & designed for input variation between 170 V to 280 V with output voltage stabilized at 230 V with accuracy of ± 2.5% (Cooling appliances-qty4, Air conditioning- qty 10) 46 AIR CONDITIONINGSupply and install,Testing & commissioning of split type air conditioner 2 TR capacity of inverter technology 5 star ratingwith cordless remote control, single phase 240 volts complete with all accessories such asindoor and outdoor units and refrigerent tubing of adequete length as required at site, indoor mounting plate, duly powder coated fixing with anchor bolts at any height, drain pipe of suitable size brought to ground level from any height, initial filling of refrigerent gas including making round hole on existing wall for taking up refrigerent tubing, drain pipe, cables etc and making good the surace by matching with adjoining surface complete all as specified and directed. 47 Supply and fix Voltage stabilizer 5 KVA for automatic operation,single phase naturally air cooled indoor type, Wall mounted type & designed for input variation between 170 V to 280 V with output voltage stabilized at230 V with accuracy of ± 2.5% 48 INTERNAL ELECTRIFICATIONS & F LED Mirror light 1 x 5W LUMOS ECCO 1 feet Make: Luker or Equivalent 49 S & F modular MCB DBOx 3 Pin Socket with MCB SP 20 Amp, 240 V including plastic enclosure as per manufacturer instruction fixed on wall surface complete for Air conditioner all as specified and as directed. (Make:-Havells, Model-DHDMCSN0251016 or equivalent) 50 Supply and fix Air circulator of 600 mm sweep AC single Phase. 230V, 1440 RPM complete all as specified and as directed. (Make: Havells model, Turbo Force Wall or equivalent) 51 S & FVertical triple pole & neutral (VTPN), double door, 16-way metallic modular distribution board conforming to IEC 61439-3, suitable for flush / surface mounting with provision for FPMCCB as incomer and TPN/SP MCBs as outgoing, reversible metal door, 200 A copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wiriest & cable ties for cable management, profited masking sheet, etc. having IK 09 & IP 43 protection complete all as specified and directed. 52 S & FVertical triple pole & neutral (VTPN), double door, 4-way metallic modular distribution board conforming to IEC 61439-3, suitable for flush / surface mounting with provision for FPMCCB as incomer and TPN/SP MCBs as outgoing, reversible metal door, 200 A copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wiriest & cable ties for cable management, profited masking sheet, etc. having IK 09 & IP 43 protection complete all as specified and directed. 53 M & L for Flame ProofMCB Distribution board SPN 12 way, with case iron body, powder painted, with 200 Amps rated bus bar etc. including provision of one 32 Amps SPN MCB as incoming and 6 Amps SP MCB -10 Nos as outgoingcomplete all as specified and as directed. 54 M & L for Flame ProofMCB Distribution board SPN 8 way, with case iron body, powder painted, with 200 Amps rated bus bar etc. including provision of one 32 Amps SPN MCB as incoming and 6 Amps SP MCB- 6 Nos as outgoingcomplete all as specified and as directed. 55 Supply and fix Engage light with Green & Red LED complete all as specified and as directed 56 Supply and fix of CS mounted high intensity LED search light, long range, manually swivel in all direction, 250 W, minimum range 700 meters, Single, LED Efficiency> 140 lm/w, PF> 0.95, CCT 5500K - 6500K, Optical grade PMMA/PC lens/reflector efficiency>95%, multiple circuit to avoid complete run down, anti UV, narrow beam 5 degree, die cast LM6 body with air fins, powder coated, constant current, an average lux at 10 meter - 8000 lux with circle of approx 600 mm, working temp: -20 to +60 degree C, input Volt 100-300 VAC, 50 Hz, PF >0.95, IP-66, confirming to LM79/ LM80 and type tested as per IS: 10322/ IS: 13383, BIS approved and Govt lab tested for lux intensity. The search light is completed with manual revolving CS stand D20cm x H15cm (min.) with 3 nos. foundation holes for mounting of searchlight on watchtower structure, manual rotation of light on horizontally 360 degree with 45 degree tiltable with provision of both instant locking arrangement at desired position. Model No. CS-LRFLL-25PC25 of KALIN make or equivalent 57 Supply, install, testing and commisisong of outdoor floor/wall mounted thermoplastic polycarbonatefeeder pillar panel, Enystar EmptyEnclosures, IP-65, weatherproof, corrosion free, Halogen and Silicon Free, Frame retardant with Opaque Lid Size-[276 x 546 x 186]mm and Transparent Hinged Lid, completed all as specified and directed. 58 M & L for TV socket module metal flushed including flushed Box cover plate Box for 2 way module complete all as specified. 59 M & L for telephone jack with module metal flushed including flushed Box cover plate Box for 2 way module complete all as specified. 60 Supply and lay coaxial cable for TV Cabledrawn through conduit 61 S & F flame proof exhaust fan 300 mm sweep, single phase, 1440 RPM complete all as specified and as directed. 62 FIRE FIGHTINGSupply and fix Foot Valve conforming to IS 4038, 100 mmdia. 63 Supply and fix Foot Valve conforming to IS 4038, 150 mmdia. 64 Supply and fix Cast Iron Air Valves with single air Outlets, conforming to IS 14845 of size 100 mm dia bore and fixing up in Cast Iron Water supply mains of size 100 mm dia. 65 S & F sprinkler flexible drop pipe 1 mtr long. 66 S & F sprinkler rossette 25 mm dia. 67 Supply and installation, testing and commissioning of Analog Addressable type Active Loop Repeater (Loop power/external power) Fire terminal with inbuit turbo isolator, Backlit LCD Display 6x40 characters display, having Controls For Reset, Mute, Accept, Silence alarms and Self Test, with programmable free keys and Duly Approved byEN54/LPCB/VDS/FM Make: SIEMENS/NOTIFIER/BOSCH 68 M & L for Low smoke Zero helogen flame retardent fire alarm cable2 core, 1.5 mm² copper conductor confirming to BS7629-I, BS6387 & rated for 500 v grade having plaine sraded copper coductutor with priming insulation of glass mica fire resistance tape & secondery insulation of high performancesilicon rubber with electrostatic screen of aluminium fire barrier Type LT53 outer sheath confirming to BS 7655, red in colour drawn through & including concealed steel conduit including laying,fixing,connecting complete all as specified and directed. 69 Staircase signage down of make bajaj cat part no. 111499 model no. DSDWBB 3W double side display for staircase downwards (with 2 hours built in battery backup) complete all as specified and directed at site complete all as specified and directed. 70 S & F wall mounted LED emergency Exit signage luminaire Lit up using regular mains supply comes with a unique rechargeable Ni-Cd battery capable of emergency back up upto 05 hours(Cat No. 220211 Make Bajaj or equivalent to CG/Havells. 71 Supply, Installation, test and Commissioning CPRI APPROVED factoryfabricated, indoor type, LT panel board , made out of 2 mm thick CRCA Sheetsingle door withboth side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embeddedwith 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete withinternal connection with suitable size of cable, cable lugs and cable glandsPCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Testing after Installation includingcomplete all as specified and comprising of the following:- Make of MCCB/MCB -MDS/LEGRAND/L&T/HEGGER (Main Fire Fighting Panel)INCOMING(i) MCCB 4 Pole 160 amp 50 Hz, 415 V with reputing capacity 35 KA with microprocessor based release - 01 No.(ii) Voltmeter Digital type 0-500 Volts range flush type with selector switch- 01 No(iii) Aluminium Bus bar TPN - 200 amps- 1setOUTGOING(i) MCCB 3 Pole 125 amp 50 Hz, 415 V with reputing capacity 35 KA with microprocessor based release- 01 No.(iii) MCB TPN 32 Amp -02 Nos(iv) 80 HP S/D STARTER- 01 Nos(v) DOL STARTER 7.5 HP- 01 Nos(vi) Motor Protection Relay32-88 amps- 1 no. (vii) Motor Protection Relay2-5.5 amps- 1 no. (viii) On/Off/Trip Indication Lamps, 220 V AC- 6 nos.(ix) Start/Stop Push Button, 2 No. (x) Phase indicating lamps RYB for incoming and each outgoing connection.(xi) Digital type Ammeter 0- 150 amps with selector switch and CT coils of suitable capacity for incoming and each outgoing connection- 1 no. 72 M & L for coating and wrapping of under ground steel pipe buried in soil shall have protection against corrosion as per IS-10221.The coating and wrapping shall be carried out in systamatic manner to get uniform thickness of coating as per IS specification 73 Supply, Installation, test and Commissioning CPRI APPROVED factoryfabricated, Indoor type, LT panel board, made out of 2 mm thick CRCA Sheetsingle door withboth side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embeddedwith 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete withinternal connection with suitable size of cable, cable lugs and cable glandsPCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Testing after Installation includingcomplete all as specified and & directedby Engr-in-charge comprising of the following :– ( Booster terrace pump panel)INCOMING:-(a) INCOMING MCCB 40 A 25 KA, 4 POLE- 01 No.(b) Busbar TPN of size 100 apms - 1 setOUTGOINGS:-(a) MCB 3 POLE TPN 32 Amps,10 KA-2 Nos.(b)DOL Starter for 7.5 HP Pump set-1 Nos.(c) Ammeter Class-1, digital panel mounting type 96mmx96mm L & T cat no WDS301FCA00 including CT 50X5 Amps 3 nos & selector switch-4 nos(d) Voltmeter Class- 1, digital panel mounting type 96mmx96mm L&T CAT NO.WDS301FEV00 & selector switch - 1 no.(e) LED TYPE indicator lamp 1 set (set of three for R,Y,B)(f) Mini protecrionRelay 4-11 amp - 1 nos. 74 Fire Extinguisher mechanical Foam type trolly mouted of 9 Liters capacity. Ceasefire 9 litrs fire Extinguisher AFFF Foam type, External Cartridge type, Pressure Guage Gross weight 14.6 Kg, empty weight5.6 Kg, Can height 611 MM, Diameter 175 MM, Discharge time less than 60 Secs controllable discharge mechanism, Minimum 6 Mtrs, Applicable on Class A, B, can construction deep down & CO2 Mig welded Valve Construction: Forging & Machining, Internal coating of can: Epoxy powder coating, External coating of can: Epoxy poyster powder coating sheet metal thickness 2.0MM,1 year warranty. Make Cease Fire Or Equivalent. (pol store) 75 Supply, Installation,Testing & commissioning of Carbon Dioxide (Co2) type fire extinguisher of 4.5 Kg confirm to IS: 15683, with ISI marked/TAC approved fitted with required accessories including wall suspension brackets. 76 Supply, Installation,Testing & commissioning ofDRY CHEMICAL POWDER (ABC) stored pressure type fire extinguisher of 9 Kg confirm to IS: 15683, with ISI marked/TAC approved fitted with required accessories including wall suspension brackets. 77 Supply, Installation,Testing & commissioning of Water Mist High pressure stored pressure type fire extinguisher of 9 Kg confirm to IS: 15683, with ISI marked/TAC approved fitted with required accessories including wall suspension brackets. 78 Supply and installation at approved location approved make Fire sand bucket of 24 gauge galvanized steel sheet, each set shall have 4 buckets with stand & Showel etc, complete. 79 SPECIAL EQUIPMENTS FOR STORESDesign, manufacture, Supply, installation, testing and commissioning of Automated Storage and Retrieval System with storage racks, pallets, stacking crane, computer hardware with compatible inventory software as a turnkey solution complete all as specified and directed. Automated Storage and Retrieval System shall consist of computer controlled & PLC stacker crane driven system for automatically placing & retrieving materials from defined storage locations. The crane shall be capable of lifiting, stacking and retriveing the pallet loads weight upto 1125 Kg (max) complete all as specified and directed by the Engineer-in-Charge. Technical data for design of heavy duty ASRS:-(a) Dimensions:-Height:10 Mtrs for racking system which shall be designed and constructed to store the required no. and size of pallets.(b)Storage capacity:-Pallet Size: 1300 (W) x 1200(D) x 1250 (H) in mmPallet Nos.: 480Pallet load capacity: 1125 KgTotal capacity: 540 Tons(c) Stacker Crane: Single mast automated stacker crane for handling Pallet, size 1300mm(W) x 1200mm (D) x 1250mm (H) and pay load (including Pallet self weight) of 1125 Kg max. The stacker crane shall be capable of picking up the pallet from in-feed conveyor or loading station and stacking it into empty slots of racking system. Similarly, it shall also be capable of retrieving the palltet from racking system and putting it on the same conveyor or unloading station. Stacker crane will be mounted on single rail at the bottom to traverse the length of the storage system. A single top rail mounted on the racking system shall also support it.General technical parameters of stacker crane:Technical parameters/Type- Single Mast(i) Operation mode (Networking)- On-line automatic / Single automatic (Ground/Boarding) /Manual operation (Boarding) / Maintenance (ii) Communication Means- Wireless 80 (iii) Power supply mode- 380 to 415 V, 50 Hz, three phase five wire (iv) Addressing mode- Horizontal and verticle operation: photo electrical sensor + bar code scanners(v) Positioning / Reduction accuracy (mm) level- lifting ± 3 - 5, Fork : ± 3(vi) Fork unit- 1 Double deep fork(vii) Load unit- MS Pallet (viii) Total Height- 10 Mtr(ix) The normal lifting speed (m/min) - 10 MPM(x) The normal running speed (m/min) - 65 MPM(xi) Rated load- 1125 Kg(xii) Receipt equipment fixed platform/conveyor/lifting /platform(electric/manual)- Conveyor(d) Pallets: to stack and retrieve the pallet weighing up to loaded pallet weight 1125 Kg at height up to the last loading level in the racking system. It should have retrieval mechanism to enable stacking & retrieval of pallet from either side of the rack and also to pick up the load directly from the loading station.Pallet Details:-(i) Dimensions - 1300mm(W) x 1200mm(D)(ii) Pallet height- 1250 mm(e) Racking system :- Two aisle having two row racking system each with 05 verticle levels for storage of material. Racking for double deep type storage of 480 Pallet of size 1300mm(W) x 1200mm (D) x 1250mm (H). Loaded pallet weight: Pay load with pallet 1125 Kg max. System details:-Working aisle -01 Nos. (Double deep)Store rack -24 Nos./RowTotal rack in 1 aisle-24 (Left) + 24 (Right)= 48 Nos.No. of level- 5 Nos/RackTotal Pallet-48 x 5 x 2 = 480 Nos.Load capacity- 1125 Kg/LevelSingle mast stacker crane-01 No. 81 (f)Aisle Equipment:-This will consist of electrical as well mechanical aisle equipments and willl be designed as per the pallet requirement. The mechanical Aisle equipment of bottom rail shall consist of I Beam and will be provided with adjustable calmps for holding the rail in position to ensure proper alignment. Top rail shall be mounted on the racking. The electrical aisle equipment shall consist of power rail (fully enclosed bus bar having 7 pole system), which is mounted on the racking system below the first loading level.(g) Details of rack members:-The racking system shall consist of cold-rolled steel sections as per manufacturers design to accommodate and store pallets and connected systems.(h) Loading- unloading station/ Conveyor(i) Pallet Load 1125 Kg max.(ii) Bearing- SKF Equivalent make(iii) Motor- Seimens/Sew Euro Drive/Nord Sew/ Bonfiglioli or equivalent(iv) Gear Box- Bonfiglioli Make or equivalent(v) V.F.D.- Yashkawa make or equivalent(j) All steel surface shall be powder coated finish with 8 tank treatment process.(k) Maintenence: The annual maintenence of complete ASRS system duyring the defect liability period of two years shall be included in the rate quoted for the system and the AMC contract duly signed with the manufacturer of the ASRS system shall be submitted at the time of handling over the system. The AMC shall include all spares and consumables etc required during the period of two years and nothing extra shall be paid on this accountNote- 1Mechanical safety provision (i) End of aisle shock absorbers / bumpers for stacker crane.(ii) End of travel buffer for the lifting crane.(iii) Safety catches on lifting carriage.(iv) Anti-tilt mechanism for the stacker crane.(v) Continuous rail cleaning brush for floor rail.(vi) Adjustable rail clamp to ensure alignment. 82 (vii) Resilient rubber pads on adjustable clamps for vibration dampening.(viii) Profile check on lifting carriage to check all three dimensions (width, depth & height) of the pallet. Note - 2 Electrical safety provision (i) There shall be Emergency stop push button at all panels and stations.(ii) Optical light beam amd mechanical safety sensor to stop the operation in case of improper storage or obstruction in the operator window either internal or external reasons like operator hand or material placed at edge of the tray.(iii) Back up circuitry for proper system operation.(iv) An electromagnetic brake shall be used to avoid the slippage of the hoist.(v) Stopper shall be provided for the maintenance door.(vi) Load cells shall be provided for the over weight of tray.(vii) Automatic door shall be provided for operator safety while machine in operating condition.Note - 3 Physical safety provision (i) The ASRS system shall comprise of safety fences having grid size of max. 40 x 40mm & wire dia should be of min. 3 mm. Height of the fencing should be minimum 2.0 meter.(ii) One No. of electromagnetic aisle access door shall be provided. It should cover the complete length of the system on one side.(iii) A manual locking system to restrict the movement of unauthorised personnel shall be provided.NOTE: Design report shall be submitted before execution of Work at site by the contractor toGE for his scrutiny / comments and futher submitted to AO for obtaining approval. Item No. 13.070 below shall be compatible with this item/ system and both should be integratedMake of ASR system:Armstrong Ltd/ Godrej Koerber/ Kardex India storage solutions Pvt Ltd/ Daifuku India Pvt Ltd/ Addverb technologies Ltd/ Craftsman Automation Ltd/ Tech-mark 83 Supply, installation, testing and commissioning of Advance Inventory Management System with computer hardware with compatible inventory software complete all as specified and directed by the Engineer-in-Charge. Technical specification of the system(i) System Height : 6400 (±100) mm(ii) System Width : 3150 (±100) mm(iii) System Depth : 2300 (±100) mm(iv) System Base : 7.24 Sq.Mtr(v) Tray Int. Size: 300 (H) x 2450(W) x 500 (D) in mm(vi) Tray dead weight - 57 Kg (Approx.)(vii) Per tray weight capacity - 300 KgTechnical specification of the system:-(viii) Tray Quantity : 32 Nos.(ix) Usable net load - 9.6 ton(x) Storage surface area per system - 39.2 sq mtr(xi) Door - Automatic(xii) Power consumption - 3.7 KW(xiii) Power supply - 440V, 50/60 Hz, 3 Phase(xiv) Motor 3 Phase 1440 RPM - Seimens make or equivalent(xv) Chain - Diamond makeor equivalent(xvi) Bearing - SKF/NTN make or equivalent(xvii) External cladding - Epoxy powder coatedSafety Features:1. Photo curtain at access port, 2. Motor Protection relays, 3. Limit switch at door, 4. Single phase preventer,5. Switch mode power supply, 6. 15 Min battery backup for PLC, 7. Noise less than 60db, 8. Emergency stop various safety alertsNote: The system and software provided under this item shall be of same make as for item 13.069 or a compatible system and software as recommended by the chosen manufacturer of ASR system. This system shall be integrated with ASR system. 84 Supply, installation and testing of Car Traffic Boom Barrier 6 mtr suitable to working on power supply 230 Volt, 50 Hz, 24V DC electric motor, adjustable with CAMS, operating ambient temperature from -20 to +55 Degree Celsius, uses cycle 2000/Day, air cooling, type of beam is rectangular with skirt, effective torque 280-290 Nm open/close time 2 to 4 Sec complete all as specified and as directed by Engineer-in- charge.Make: FAAC/Parkilo/Skidata/BFT 85 EXTERNAL WATER SUPPLYSupply and fix Foot valve conforming to IS,100 mm dia complete all as specified and directed. 86 Supply and fix Cast iron air release valve with 100 mm bore and two outlets as per IS:14845 complete all as specified and directed. 87 Supply, installing, testing and commissioning of electrically driven horizontal Centrifugal Pump set 9.0 LPS at 50 Meter Head as per specification, motor TEFC type, 2880 rpm, 415 V, 50 Hz, 3 phase, class F insulation, IP 55 protection, starting on suitable Star Delta starter. The pump shall be horizontal, end suction, top discharge. The pump shall have cast iron casing, cast iron/bronze impeller (as per manufacturer), carbon steel shaft with common base frame (fabricated mild steel channel frame or cast iron type) placed on RCC (1:2:4) including foundation, bolts, nuts etc. complete with antivibrator pad as required capable of discharging not less than 550 LPM at 45 mtr head inclusive of suitable rated three phase starter as recommended by the manufacturer, PVC insulated copper cable connection from starter to the motor terminals all as specified and directed by the Engineer-in-charge.(01 No. Working + 01 No Stand By)Make:- Kirloskar Brothers/Crompton or equivalent. 88 Supply, install, test and commissioning of LT Panel, indoor type, powder coated, 2.0 mm thick CRCA Sheet, CPRI approved having, IP 43, MS angle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with Horizontal copper bus bar for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 2.0 mm thick CRCA Sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables. Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, track resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. andcomprising as under: LT Panel for Pump House. The LT Panel comprising of the following:- 89 Incoming:-MCCB, thermal magnetic release, 4 pole, 415 Volts, 100 Amps, breaking capacity 36 KA- 01 No. Ics =100% IcuMetering Unit:- (a) R Y B Indications (LED Type)- 01 sets(b) Digital Multi function meter - 01 No.(c) CTs - 100/5A, CL-1, 15 VA - 01 set(d) Horizontal Aluminium busbar for 3 phase, 440 volts, 50Hz, 4 wire system of rating 350 Amps for phase and 350 amp for the neutral barOutgoing:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 63 Amps, breaking capacity 16 KA- 02 No. Ics =100% Icu -2 nos.(b) MCB, TPN 40 Amp, 415 Volt, C Curve - 02 Nos.(c) Star Delta starter 12.5 HP, 3 Phase, 415 Volt- 02 Nos.(d ) Digital ammeter - 2nos.(e) Single Phase Preventer - 2 nos. 90 M & L Valve chamber of internal size 0.90m X 0.90m X 0.90m (internal dimensions) including excavation of earth work in any type of soil, 150mm thick PCC in 1:4:8 type D2 foundation, brick work in CM 1:6, 15 mm thick rendering in CM 1:4 to internal surfaces and external surfaces upto 150mm depth below GL, PCC 1:3:6 type C1 as in coping, cover with two Nos. of hinges and one No. handle made out of MS round bar 10mm dia with necessary locking arrangement including painting to the steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer complete all as shown on drg and as specified. Note:- The quoted rate shall include all earthwork and connected items. 91 M & L Earthing complete with Galvanized steel earth plate electrode of size 600mmX600mm, 6.00 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below the normal ground level with top edge of the plate not less than 1.5m below normal GL and connected to galvanized iron strip of size 32 x 6 mm size by means of bolts, nuts, check nuts and washers of galvanized iron steel all as shown in Electrical Plate No. 3 connecting to earthing test point, including necessary earth work in any type of soil, PCC earth chamber made in PCC 1:3:6 type C1 (using 20mm graded aggregate), common salt, charcoal, CI funnel, earth pit cover in RCC 1:2:4 type B1 (using 20mm graded aggregates), with 8mm CTD bars @ 100mm c/c in both ways, including necessary form work complete including necessary test on completion all as specified and as directed. 92 EXTERNAL ELECTRIFICATIONM & L for HT/LT MS cable route indicator, engraved the description on the disc not less than 6 dia welded with 40x6xmm MS strip of approx length 90 cm duly painted on the steel parts as per colour code and provision of PCC 1:4:8 type D-2 using 40 mm grade stone aggregate of not less than 0.05 cum in each at base under the ground including necessary earth work and formwork complete all as specified and directed.Note: HT route indicator shall be painted as under:-(i) For HT 11 KV cables - “BROWN”(ii) For LT cables - “BLUE” 93 Supply and fix compact air insulated bus bar trunking system with copper busbar 1600 Amps, 50 KA breaking capacity, IP54 protection, bus duct 1600 A, 415 Volt, capacity sandwich type, Set RYBN complete with accessories such as flange ends, vertical bends, supporting brackets etc from transformer to LT panel board complete all as specified and directed. 94 Supply, install, testing and commissioning of Distribution transformer step-down Level 2 (Previously EE Level 3 before Amendment No 4 to IS 1180), 11KV0.433KV, Three Phase complying withIS: 1180/IEC-76(Part-1) 2014 with latest amendments, indoortype double copper wound suitable for 50 Hz system of capacity 800 KVA, oil immersed naturally cooled delta connected on HT side and Star connected on LT side, Vector Group Dyn11, provided with OFF load tap changer to vary secondary voltage from -7.5% to + 7.5 % in step of 2.5 %.Losses should be confined to the limits specified as follows: maximum allowable losses atfull load (100 %) & Half Load (50 %) shall not be exceeded 5838 watts & 2147 Wattsrespectively as per GRlHA RATING, Percentage Impedance: 4.5%. Losses and Impedance are subjected to tolerance as specified in IS 1180. The transformers should be supplied with first filling of oil confirming to IS 335. The transformer should have both side cable end box with neutral brought out complete all as directed by Engineer - in -Charge, and installation of transformer shall be carried out as per IS-10028and comprising with the following standard fittings/Technical specifications:-(a) Lifting lug for transformer and tank.(b) Earthing terminal rating and diagram plate.(c) Air release device.(d) Oil filling inlet pipe with plug.(e) Drain outlet pipe with brass gate valve.(f) Conservator tank with oil level indicator(g) Silica jel breather(j) First fill of oil upto level including conservator tank with fresh new oil conforming to IS335.(k) Type of connection Delta/Star(l) Type of cooling: Oil and Natural Air.(m) Vector group: DYN 11.(n) Temperature rise over an ambient of 50 °C maximum.(o) Cable end box on both side for HT/LT cables of suitable size.(p) Provision of thermometer with pocket.(q) Provision of oil and winding temperature gauge. 95 Supply, install, test and commissioning of LT Panel, Indoor type, powder coated, 2.00 mm thick CRCA Sheet, CPRI approved having, IP 43, MSangle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply,bus bar chamber with Horizontal copper bus bar for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air.The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 1.6 mm thick CRCA Sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables. Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, track resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. andcomprising as under: The LT Panel comprising of the following:- Main LT PanelHorizontal copper busbar for 3 phase, 440 volts, 50 Hz, 4 wire system of rating 1600 Amps for phases and 1600 Amps for Neutral. 96 Incoming:-Incomer:-ACB 4 Pole, 415 V, 50 KA with Thermal Magnetic Release (Manual Draw out type) of capacity 1250 AmpMetering Unit:- (a) R Y B Indications (LED Type)- 1 sets(b) Digital Multi function meter - 01 No.(c) CTs - 1600/5A, CL-1,15 VA - 1 setOutgoing:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 630 Amps, Ics =100% Icu, breaking capacity 35 KA, Ics =100% Icu- 02 No. (For DG AMF Panel & Spare)(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 400 Amps, Ics =100% Icu breaking capacity 36 KA- 02 No. (for APFC Panel & FPB 2 Near bulk Store) (c) MCCB, thermal magnetic release, 4 pole, 415 Volts, 320/315 Amps, Ics =100% Icu breaking capacity 36 KA- 01 No. (for FPB 1 Near Adm Block) (d) MCCB, thermal magnetic release, 4 pole, 415 Volts, 200 Amps, Ics =100% Icu breaking capacity 36 KA- 01 No. (for Existing Load)(e) MCCB, thermal magnetic release, 4 pole, 415 Volts,125 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for FPB 3 Near Auction Disposal Store)(f) MCCB, thermal magnetic release, 4 pole, 415 Volts, 32 Amps, Ics =100% Icu breaking capacity 25 KA- 03 No. (for MT Complex, Watch tower no 2, Guard room)(g) Digital Ammeter with suitable CT for each outgoing 97 Supply, install, test and commissioning of LT Panel, outdoor type, powder coated, 3.00 mm thick CRCA sheet, CPRI approved having, IP 54, MS angle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply,bus bar chamber with Horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 2 mm thick CRCA sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables. Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, crack resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. Feeder Panel No.1 (Near Admn bldg) 98 Horizontal Aluminium busbar for 3 phase, 440 volts, 50Hz, 4 wire system of rating 600 Amps for phases and 600 Amps for Neutral.Incoming:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 400 Amps, breaking capacity 36 KA - 01 No. Ics =100% IcuMetering Unit:- (a) R Y B Indications (LED Type) - 1 sets(b) Digital Multi function meter - 01 No.(c) CTs - 600/5A, CL-1,15 VA - 1 setOutgoing:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 200 Amps, Ics =100% Icu breaking capacity 36 KA- 02 No. (for 2nd floor & spare)(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 160 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for 1st floor)(c) MCCB, thermal magnetic release, 4 pole, 415 Volts, 63 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for G floor)( d) Digital Ammeter with suitable CT for each outgoing 99 Supply, install, test and commissioning of LT Panel, outdoor type, powder coated, 3.00 mm thick CRCA sheet, CPRI approved having, IP 54, MSangle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply,bus bar chamber with Horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air.The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 2 mm thick CRCA sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables.Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, crack resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. Feeder Panel No.2 (Near Bulk Store) Horizontal Aluminium busbar for 3 phase,440 volts, 50Hz, 4 wire system of rating 600 Amps for phases and 600 Amps for Neutral. 100 Incoming:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 400 Amps, breaking capacity 36 KA - 01 No. Ics =100% IcuMetering Unit:- (a) R Y B Indications (LED Type)- 1 sets(b) Digital Multi function meter - 01 No.(c) CTs - 600/5A, CL-1,15 VA - 1 setOutgoing:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 200 Amps, Ics =100% Icu breaking capacity 36 KA- 02 No. (for Equipment Load & spare)(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 125 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for Bulk Store)(c) MCCB, thermal magnetic release, 4 pole, 415 Volts, 32 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for Watch Tower No. 1)( d) Digital Ammeter with suitable CT for each outgoing 101 Supply, install, test and commissioning of LT Panel, outdoor type, powder coated, 3.00 mm thick CRCA sheet, CPRI approved having, IP 54, MSangle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply,bus bar chamber with Horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 2 mm thick CRCA sheet, duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables.Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, crack resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. Feeder Panel No.3 (Near Auction Disposal Store) 102 Horizontal Aluminium busbar for 3 phase, 440 volts, 50Hz, 4 wire system of rating 200 Amps for phases and 200 Amps for Neutral.Incoming:-(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 125 Amps, breaking capacity 25 KA- 01 No. Ics =100% IcuMetering Unit:- (a) R Y B Indications (LED Type) - 1 sets(b) Digital Multi function meter - 01 No.(c) CTs - 200/5A, CL-1,15 VA - 01 setOutgoing:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 100 Amps, Ics =100% Icu breaking capacity 25 KA- 02 No. (for Store Dispatch Complex & Spare)(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 32 Amps, Ics =100% Icu breaking capacity 25 KA- 03 No. (for Pol store, Auction disposal store, Covered Hard Standing)(c) Digital Ammeter with suitable CT for each outgoing 103 Supply and fixing poly carbonate street light junction boxes IP 66/67 Weather proof suitable for outdoor installation having minimumsize255 x 355 x 122 including suitableCable connecting Terminals, Cable lugs, including provn of one No. MCB SP 6 Amps for operating the street light fittings, Suitable Cable Glands as per site requirement, all as directed by the Engineer-in-Charge. 104 S & F Street light bracket made out of GI tubing 32/40 mm dia, light grade of length1.2 mtr long bend to shape suitable for security light fitting with necessary MS clamp-02 Nos with one coat of anti corrosive primer and two coats of aluminium paint including nut, bolt, washers and 3 core FRLSinsulated sheathed, multistranded copper conductor of size 1.5 sqmm for phase and neutral and 1.5 sq mm for earthing drawn throughthe poles for connection from junction box to light fitting complete etc all as specified.Note: Phase should be Red/Yellow/Blue, neutral should be black and earthing wire should be green in colour. Two runs of cable for phase and neutral and one run of cable for earth will be measured and paid as one unit length. 105 Supply and fixing of LED flood light, 200W, watt 230 V, AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp and made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP protection incl system efficiency >110/120LPW 10KV SPD included Energy saving, environmental friendly and general purpose lighting complete all as specified and directed Engineer-in-Charge. Make : Make : Crompton/Philips/Wipro 106 Supply and fix High Mast Panel outdoor type, suitable to take load up to 6 KW, Conforms to IS/IEC 60947-4-1, Provided with Protection Degree IP 54, Extended wide band (150 Vac - 300 Vac) coil, FRLS (Fire retardant low smoke) Internal wiring, In-built Short-Circuit Protection, Class H Insulation, 3 Phase 415 Volts AC with the following accessories:Phase : 3 Phase, 415 VoltsMax Load Capacity : 6 KWTimer type: AstronomicalContactor Rating : 32 A TPMCB Rating : 63 A TPNMake : Crompton/ Philips/Wipro 107 Supply and laying DWC (Double wall Corrugated) duct pipe outer dia 63 mm and inner dia 50 mmconforming IS 16205 (Part 24 ) for protection ofelectric cable complete all as specified and directed. ( for 10 sqmm St light cable & 16 Sqmm cable) 108 AVIATION OBSTRUCTION LIGHTSupply and fix aviation obstruction light integral aviation light comprising of aluminium housing with polycarbonate enclosure, 240 volt with timer switch and one No.10 A, MCB, SPN 230 V with fixed enclosure complete all as specified and directed by Engineer-in-charge.Make:- Bajaj cat No BGAV 302 LED or equivalent in Philips/Crompton/Surya 109 INCINERATORSupply, fixing and testing of Solid waste Electric Incinerator, single chamber type having a combustion chamber supported with electric coil for generating sufficient heat to burn 100Kg/hr solid waste, retains and re-burns the exhaust gases for minimum of 2 seconds at 850°C, Stainless steel stack for longevity, fitted with a Velocity Cowl as standard, Chamber designed for maximum air flow and circulation which in turn improves efficiency and total burn time, easy to open and close loading door, designed to increase operator safety, steel cladding to reduce risk of infection and increase longevity of system with working temperature not less 450 degree Celsius mounted on foundation as recommended by OEM including electrical control panel with suitable size MCCB, relays & contactor recommended by OEM complete all as complete all as specified and directed.Note:(a) The electrical works including electrical LT panel, internal wiring of the LT panel, suitable size copper wires from panel to Solid waste Electric Incinerator as recommended by OEM to operate the Solid waste Electric Incinerator of capacity 100 Kg/Hr to make Solid waste Electric Incinerator operational is deemed to be included in the rate quoted. (b) All Electrical works shall be carried out as per relevant BIS/lS equivalent standard norms only and also in accordance with the latest edition of the Indian Electricity Act / rules formed there under and as amended from time to time.(c) Any other works (mechanical, electrical & Civil) connected to installation, testing & functional requirement of Solid waste Electric Incinerator of capacity 100 Kg/Hr all as mentioned above and which is not mentioned or included in this Schedule but required at site necessary shall be carried out by the contractor and quoted rate shall deemed to included for the same.(d) Foundation/Plinth/Base: shall be provided as per manufactures recommendations, however minimum 0.5m space should be available all around the Solid waste Electric Incinerator and height of plinth shall not be less than 0.5 M 110 Supply & fixing MCCB, thermal magnetic release, 4 pole, 415 Volts, 200 Amps, breaking capacity 36 KA- 01 No.Ics =100% Icu with Sheet metal enclosures fixed properly at directed location and connecting/testing complete all as directed. 111 ELECTRIC SIRENSupply and fixing Sirens Electronic type Horizontal Double Mounting Three Phase 400/440V, 2800 RPM 50 C/s Flame Proof, audible range 3.5 Km, 2 HP, continuous normal operation for at least 50 minutes with on/off system complete all as specified and directed. 112 Supply and fix advance Sirens controller Electronic type suitable to operate on 3 phase, 415 volt AC 50 Hzcomplete all as specified and directed. 113 Supply & fixing MCCB, thermal magnetic release, 4 pole, 415 Volts, 63 Amps, breaking capacity 25 KA- 01 No.Ics =100% Icu with Sheet metal enclosures fixed properly at directed location and connecting/testing complete all as directed. 114 SOLAR POWER PLANTDesign, supply, installation testing and commissioning of roof top solar photovoltaic power plant (ON-GRID) on roof top of existing bldg of capacity 150 KWp, power evacuation at 415 Volt 3 phase system all as per guidelines/norms issued by MNRE & Indian Metrological Deptt approved Solar Radiation Data viz Direct Normal Irradiance, Global Horizontal radiance etc complete comprising with the following Solar Photo Voltaic Plant.(a) Design, supply, installation, testing and commissioning of Solar PV Modules capable of generating 150 KWp (AC) electricity at 415 Volt 3 phase system. These Solar PV Modules of 540 watt PERC with a modular efficiency of 17-19.84% as per IEC and MNRE standard or as per approved design parameters with Poly/Multi Crystalline Silicon Solar cells of minimum wattage of 540 watt with minimum 144 cells & efficiency not less than 17 -19.84%, conforming to IEC 61215, IEC 61730, IEC 61701. Solar PV Module should be of approved Indian Brand only and Qualify under the Domestic Content requirement (DCR) norms of NVVN/SECI and testing requirement fixed by MNRE. The PV modules shall be warranted for a period of minimum 25 years, Solar PV modules used in system shall be warranted for their output peak watt capacity, which should not be less than 90% at the end of Ten years and 80% at the end of Twenty Five years. Each Solar PV Module must use RF identification tag. The following information must be mentioned in the RFID used in each module:Name of manufacture of PV module, Name of manufacturer of Solar cell, Month & year of manufacturer (for solar cell and module), Country of origin (lt is mandatory to use cells and modules manufactured in India). I-V curve of the module, Wattage, LM, V-M, & FF for the module, Unique Serial No & Model No of the module, Date & year of IEC PV qualification certificate, Name of the test lab issued IEC certificate. The PV modules used in the solar power projects must qualify to the latest edition of the following International Electro technical Commission (IEC) P module qualification test or equivalent BIS Standards. The PV module must be tested and approved by one of the IEC authorized test centres. 115 (b) Material and labour for Module Mounting structure (MMS) fabricated from hot dip galvansied iron section of suitable size with specified tilt angle according to site requirement & optimum angle to achieve maximum benefit of solar energy and suitable to withstand 180 Kmph wind speed all as per approved design parameters as per MNRE standards and to match with the existing site conditions. Necessary roof treatment to avoid any seepage in future shall be done by the Contractor and the amount included in the rate quoted. The roof tiles shall be dismantled and refixed back in original position. Structure shall be built with brick masonry basement of adequate size as per direction at site including all necessary civil work required for the foundation.(c) Supply, laying & Testing of DC cable minimum size 4/6sq mm multi stranded copper conductor, conforming to relevant IS, weather proof UV resistant with operating temperature up to 120 degrees, minimum rated voltage 1100 volt for inter connection of SPV Modules to array junction box including suitable size of cable lugs, male & female MC4 connectors & joints etc.(d) Supply, installation test and commissioning of protection devices MCCB 400 A, isolator and three phase 4 wire LT energy meter, array junction boxes having rating 150 KWp with over voltage protection and surge protection.(e) Supply, installation, test and commissioning of Grid tie Solar Power conditioning unit / inverter of minimum capacity 150 KWp(DC to AC 415 V in Three phase system) all as per approved design parameters & capable of generating output voltage 415 V AC at rated load condition with efficiency not less than 98 %, conforming to IEC 600682-2 NDE standards with power reduction, LVRT with protections for anti-islanding, Ground fault monitoring, Grid Monitoring, AC & DC Over voltage and under voltage protection, AC & DC short circuit lover current protection and DC reverse polarity protection, graphic display etc. all as specified and as directed.(f) Material and labour for Earthing for Lightning protection for SPV modules etc as per IE rule, MNRE guide line & BIS all as per approved plan complete with galvanised earth plate electrode 600x600x6 mm thick buried directly in ground vertically (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected to and including Gl strip 32x6mm size protected with Gl medium grade pipe 40mm dia for earth electrode up to test point by means of GI nuts, bolts, check nuts and washers including earth work excavation, PCC (1:3:6) type Cl pit and RCC cover ( 1:2:4) type Bl and funnel, with necessary charcoal, salt etc complete. 116 (g) Supply and fixing aluminium strip of size 25 x 3mm thick for roof / down conductor fixed on insulators/ saddles of suitable size for SPV modules lightning protection upto interconnection between Roof top LA to Ground Earthing system. (h) AC Cable: Supply and laying of 150 Sqmm LT XLPE insulated, screened PVC bedded, sheathed with multi-stranded aluminium conductor armoured with galvanised steel wire 1100 volts grade heavy duty conforming to IS 150 Sqmm x 3.5Core as per site requirement.Note (i) :-(a) Before quoting the bid, Contractor or his authorised Engineer/consultant must visit the proposed site to study the site condition.(b) Before commencement of work, contractor shall submit drawings & lay out plan with scale including required qty to Accepting Officer for approval.Note(ii):-(a) The mechanical structures, electrical works and overall workmanship of the Grid solar power plant must be warrented for a minimum of 5 years.(b) All Mechanical, Electrical works shall be carried out as per relevant BIS/lS equivalent standard norms only and also in accordance with the latest edition of the Indian Electricity Act / rules formed thereunder and as amended from time to time.(c) Any other works (mechanical, electrical & Civil) connected to installation, testing & functional requirement of solar photovoltaic power plant of capacity 150 KWp (AC) all as mentioned above and which is not mentioned or included in this Schedule A but required at site necessary shall be carried out by the contractor and quoted rate shall deemed to included for the same(d) Contractor shall provide adequate Spares/items required for minimum period of 1 year maintenance including DC & AC items under scope of work.Note (iii) : Design report shall be submitted before execution of Work at site by the contractor toGE for his scrutiny / comments and futher submitted to AO for obtaining approval. 117 DG SETSupplying, installing, testing and commissioning, factory assembled silentDiesel Engine driven generator set, fully wired alternator AC to give an out put of 400 KVA continuously rating at a power factor 0.8 lagging, 3 phase 4 wire, 415 volts 50 Hzsupply, 1500 RPM, directly coupled with diesel engine liquid cooled mounted on common base frame complete with floor mounting fuel tank (service tank) of adequate capacity with fuel line & accessories, PCC foundation work as per manufacturers instructions, vibration damper pads, control panel & other accessories etc and comprising of following.(a)Diesel Engine: Liquid cooled turbo charged with after cooler to deliver suitable BHP at 1500 RPM under NTP conditions of BS 5514 and conforming to IS 10001/ 10002, DIN 6271 & ISO 3046 with an overload capacity of 10% for one hour in any 12 hours continuous operation with the following accessories:. Diesel engine of rated speed at full load electric start developingwithsystem with radiator and including electronic governor control of class A1, engine control panel, lub oil pump, water pump, fuel tank, exhaust pipe with silencer and suitable for electric start with batteries ofadequate capacity and suitable for alternator of specified capacity complete with fly wheel direct/flexible coupling and coupling guard complete.(a) Radiator with blower fan or heat exchanger with guard.(b) Pipe coupling for engine cooling system piping.(c ) Corrosion inhibitor coolant(d) Paper element filters(i) Fuel filter(ii) Lube oil filter(iii) By pass(e) Fly wheel housing and fly wheel to suit alternator.(f) Engine bearing mechanism in fly wheel housing.(g) Shut off coil with safeties for LLOP/HWT/over speed.(h) Dry type air cleaners and vacuum indicators.(j) Residential silencers.(k) Stainless steel exhaust flexible bellows. 118 (l) Motor driven priming pump.(m) Battery charging alternator.(n) Exhaust piping made out of STIC C class, MS pipe inclusive of all accessories and hardware, necessary supports scaffolding as per manufacturers recommendations to sustain back pressure with rain cap.(o) Mineral wool insulation 2 inch thick suitable for 400 degree Celsius temperature cladded with aluminium sheet o30 gauge for the entire length of exhaust pipe.(p) First fill of oil, coolant and diesel during commissioning and 12 hours testing.(q) Interconnecting copper cabling of adequate capacity batteries control.(r ) Fuel pipe class STIC 1 /1.5 /2 dia - 01 lot(s) Self starter 12 volts DC.(t) Electric operated electronic governor.(u) Fuel injection pump.(v) No of cylinders - 12 No VEE(w) Electronic instrument panel, complete with all accessories as per manufacturers specifications displaying the following:-(i) 12vx2 nos -24V Battery. (ii) Water temperature.(iii) lubricating oil pressure.(iv) Engine speed -1500Rpm(v) Engine hours(vi) Frequency.(vii) Voltage.(w) Safety control (Trip and indication).(i) High water temperature(ii) Low lube oil temperature(iii) Overspeed stop 119 (x) Base frame: Sturdy, fabricated welded construction, channel iron base frame (duly painted) for mounting engine and alternator as per manufacturers design alonwith AVM pads.(y) Battery:-24 volts(2x12v Battery) DC, 180AH, maintenance free battery conforming to IS:14257 with leads & terminals (Make- Excide/Amron).(z) Fuel tank:12 hrs. full load diesel storage capacity fuel tank with mounting brackets factory made of 5mm thick HR/MS sheet with level indicator fuel inlet, fuel outlet, air vent, drain plug, in let arrangement for diesel filling fro exterior canopy (without opening its panel) etc complete all as specified and directed.(aa) Isolator panel with 250 amp MCCB(ab) Auto logic panel for automatic stat(b) Alternator: Alternator suitable rated for 400 KVA, 0.8 pf , 415 volts, 3 phase, 4 wire, 50 Hz at 1500 RPM, self excited and self regulated with AVR brushless, screen protected, drip proof , insulation class-H, IP -23, voltage regulationgrade - VG 3 self ventilated and conforming to BS: 5000 / IS: 4722 suitable for engine as mentioned here-in before, conformig to IS: 13364(part-1)Make: KOEL GREEN / stampford/crompten/kirloskar/Greaves(c) Acoustic Enclosure:- M & L for acoustic enclosure for the above 400 KVA DG set to reduce noise level to 75 dB measured at 1.0 meter distance for audible frequencies as per guide of Central Pollution Control Board andmanufacturers specification and comprising of following from authorised GOEMs of Gen Set manufacturers specified :-(i) Sound insulation : 100mm thick Rock wool (Density 64 Kg/Cum).(ii) Outer body : 1.6mm thick CRCA(iii) Door : 1.6mm thick CRCA(iv) Base frame : ISMC 300(v) Inside illumination : 1 No.- 1 x 18 watt LED fitting of make Phillips/ Bajaj/ Crompton.(d) AMF Control panel:- Factory fabricated cubicle type, free standing, floor mounted, indoor type, IP-43, AMF control panel, provided with removable rear panels & hinged front panel for easy accessibility, fabricated out of not less than 2.0mm thick CRCA sheet including two coats of powder coated paint over a coat of red oxide primer etc and comprising of following: 120 (e) AMF control circuit with 4 pole MCCB 630 Amps - 2 nos, with ultimate breaking capacity Icu-50 KA at 415 volts and microprocessor release conforming to IEC 60947 Part-I with breaking capacity Ics=Icu at 415 volts , thermal overload setting 70% to 100%, short circuit setting 5 to 10 times-02 Nos. for main supply & DG set supply with HRC back up fuse complete with all DC control relays/ Line voltage monitor (LVM) as per OEM specifications incorporating motorised stored energy operating Engine start, stop, three attempt starting facility and failure to start etc.(f) Digital load manager : Three phase 4 wire indicating V,I,PF, KVA, KW, F of Enercon make with serial communication port model No.EM6400 with class 1.0 accuracy meter or equivalent make suitable rating of CT per phase- one No.(iii) Indication lamp R, Y, B with 3 Nos. of 2A HRC fuses-10 sets.(iv) Bottom gland plate for incoming and outgoing cables.(v) Circuit diagram plate.Note :- DG set should be as per CPCB -4 latest norm wef 01 July 2023 of National Clean Air programme (NACP) Act 1981. 121 Supply, install, test and commissioning of LT Panel, Indoor type, powder coated, 2.00 mm thick CRCA Sheet, CPRI approved having, IP 43, MSangle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply,bus bar chamber with Horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natuaral flow of air.The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 1.6 mm thick CRCA Sheat duly compartmentalised for each control gear with louvers and air vent gasket for natuaral flow of air and suiatable provision to accomodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables.Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, track resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. Feeder Panel No.1 (DG Panel ) 122 Incoming:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 630 Amps, breaking capacity 36 KA - 01 No. Ics =100% IcuMetering Unit:- (a) R Y B Indications (LED Type) - 1 sets(b) Digital Multi function meter - 01 No.(c) CTs - 800/5A, CL-1,15 VA - 1 setOutgoing:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 400 Amps, Ics =100% Icu breaking capacity 36 KA- 02 No. (for Package AC Bulk Store & spare)(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 160 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for Pump House & Fire Pump)(c) MCCB, thermal magnetic release, 4 pole, 415 Volts, 80 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for Incianator)(d) MCCB, thermal magnetic release, 4 pole, 415 Volts, 32 Amps, Ics =100% Icu breaking capacity 25 KA- 07 No. (for Terrace pump 1, Terrace pump 2, Power House, High mast 1, High mast 2, Street Light)(e) Digital Ammeter with suitable CT for each outgoing(f) Astro Time switch for 3 phase 20A- 1 No(g) 3 Phase Power contactor 20 amps, with 230 coil 123 SEWAGE DISPOSALM & L for laying of DWCPE sewage pipes line 200 mmdia borepipe sftiffnessclass SN 8 includingsealing of joints fittings etc complete with collers complte all as spcified and directed 124 M & L for laying of DWCPE sewage pipes line 150 mmdia borepipe sftiffnessclass SN 8 includingsealing of joints fittings etc complete with collers complte all as spcified and directed 125 COMPOUND WALLS & F Concertina Coil of 600/700 mm outer dia made out of 2.60 mm dia spring steel wire dipped in corrosion preventive fluid (rusilo 901) of castrol make each coil having min 50 turns (circles) covering 6 m and an average weight not less than 8.57 Kg (plus or minus 5 %) incl handle and spike at both ends of coil erected in position on top of mild steel angle by fixing with 1.70 mm GI wire for securing, coil with fish hook bars, incl necessary welding to MS Sections etc all as specified and directed. 126 GREEN BUILDING NORMS(GRIHA CONCEPT)Supply and Install Organic Waste Converter fully automatic having capacity 50Kg/day, having internal tank made of high quality stainless steel while external panels are powder coated for enhanced product life with necessary electric control panel, cabling necessary civil works for installing machine etc with following requirements:-Type of machine: Fulley automatic in-vessel composterComposting method: 24 Hrs. Micro-organisms-based compostingmachine Type of microganism used: Heat resistant thermophilic bacteria Final Output: Dry organic Soil conditioner/Soil supplementsCycle time: 24Hrs Volume reduction in 24Hrs: 80-85% Internal tank: Stainless steel type Main agitator Shaft: Stainless steel type Input voltage: 415VSpecial features: VFD as standard across all models, Touchscreen standards Daily waste processing: 150Kgs Rated capacity: 7KWPower consumption (KWH par cycle): 13-15Length: 1650, Width: 850,Height: 1455 127 Supply, installation, testing and commissioning Three phase energy meter with the following specifications: Microprocessor based three phase, smart electricity meter, equipped with a bi-directional cellular (NB-IoT) communication that allows it to interact with the head end system (HES) for data collection and configuration with adequate security including electronic static pre paid cum postpaid energy meter rating 415 Volts, 50 Hz of range 10-100 Amps, complying to IS16444:2015 (reaffrimed 2020) and conforming to IS 3779 with LED display and parameters like Voltage, Current, Frequency, Power, Power factor, KWH/KVA, default in built dual source, inbuilt long range (LORAWAN) Communication suitable for outdoor LoRa data accumulator and also compatible for Prepaid and Postpaid online energy monitoring billing system with disconnection /reconnection through remote software / data export to ERP complete with 5 Years warranty.Note:(a) The contractor would be responsible for removing the existing meter, noting down the reading and depositing it with the MES AGE E/M store complete all as specified & directed.(b) The Energy Meter to be capable of running in both prepaid and postpaid mode.(c) The meters to carry 5 year warranty. (for entire system) 128 Supplying, Fixing, Commissioning and testing of configuration of cloud Hosted multi user web based software with following modules:(i) Head End System (HES): to acquire meter data automatically from DCU sand monitor parameters acquired from meters.(ii) Meter Data Management ModuleThe meter data management module would be responsible for collecting the data from the data concentrator and make the data available to the billing system. The system would support offline meter(a) 30 min instantaneous data from all the meters for seven parameters Cumulative Energy. Cumulative Apparent Energy (as applicable), Power, Current, Voltage, Power Factor and Frequency(b) Monthly billing survey data for cumulative energy and max demand(iii) Billing Module: The billing module would collect the data from the meter data management module, calculate the energy consumption, calculate billing determinant and make energy data/billing data available to admin and end users. The billing module would include functionalities for tariff setup, bill format setup, bill adjustment, occupation billing and vacation billing. It would allow postpaid and prepaid functionality as required.(iv) Occupation and Vacation Module: The system would support occupation/vacation based on the unit catagories. The system would support automatic data capture on occupation and vacation events.(v) Website: There would be a dedicated website forAGE/GE and BSO team to view all the data and information alongwith customer portal for use of customer. The designated users in MES would have the admin access to the application. The MES Staff would also have the access to the key information on mobile App (AndroiandiOS based) for admin use complete all as specified and directed.(vi) Customer Module: The system would include a customer portal for the resident/occupants to login and view their own energy /billing data and recharge facility. There shall be consumer App (Android and iOS based) also to log in and view their own energy/billing data and recharge facility.(vii) Communication Module :The system would provide communication of energy data and bills via print, email and sms methods. 129 (viii) Meter Master Data: The system would support meter data repository. The system would support meter replacement process.(ix) Excel Export: the system would support export of metering and billing data in excel and pdf format.(x) Energy Accounting module: The system would include features of energy accounting, the system would to able to account for total energy block wise, facility wise and would also allow calculations of the unaccounted energy in case total energy meter is also available.(xi) Prepayment/Recharging Facility:The system should periodically monitor the energy consumption of prepaid consumers and decrease the available credit based on the consumption. The system should allow online/digital recharging through consumer App (Androidand iOSbased) and Web portal. The configuration and necessary arrangement for payment gateway and E-MRO facility shall be deemed to be included in the quoted rate. The system should sendconnect/disconnect command on the basis of available credit.Low credit alarm: The system will give an alarm over the consumer App and SMS to the registered mobile number in case the credit in the meter goes down be low apredefined limit.Emergency credit: The meter will work even when the credit falls down to zero to prevent disconnection. This limit shall be configurable. The system should support happy hours inorder to prevent disconnection in non working hours and on holidays. The Happy hours should be configurable complete all as specified and directed. 130 Supply, Installation, Testing and Commissioning of DCUs/Gateways and the arrangement of Sim cards or Internet to enable reliable medium for two-way communication between Smart Meter & HES. The data acquisition (Push/Pull) frequency shall be, configurable. It shall push events such as tamper, power off etc. to HES immediately on occurrence/receipt from meters. It shall have provision for the cellular, WiFi and Ethernet communication for the backhaul to HES. It shall be capable to handle data of minimum 1000 Nos. of any type of smart meter (1ph/3ph).It shall be able to communicate with the nearest meters at a distance of at least 500 m, depending on topographical features. Communication of the nearest meters with other meters shall be established through appropriate mesh formation. RF Mesh shall support self-forming and self-healing features. The equipment shall be weather proof and dust proof (minimum rating: IP54 for indoor and IP65 for outdoor installation). It shall have rechargeable battery with backup for 1(one) hour for normal meter reading, to push tamper event, carry out on demand reading, etc complete all as specified and directed. 131 Hosting GPRS (4G) charges for Gateway for five years from the date of completion F Including 2 years waranty and 2 years Maintinance after warranty) Make:-Airtel/Jio/Vodafone 132 Supply and installation of digital Water flow meter 50mm suitable for domestic and commercial applications complete all as specified and directed. 133 Supply and installation of digital Water flow meter 40mm suitable for domestic and commercial applications complete all as specified and directed. 134 ARBORICULTUREM & L for excavation of pits size 30cm x 30cm x 30cm in loose soil and filling the pit with mixture of river sand and approved top soil in the proportion of 1:3 mixed with 30% of cow dung powder, 100gms of bone meal and 100gm of neem cake powder 135 All as per item No 13.121 above but pit size 60cm x 60cm x 60cm 136 Supplying and planting red palm or royal palm healthy sapling having 45cm height and shall have a minimum height of 65cm after 6 months 137 Supplying and planting coconut tree healthy sapling having 75cm height and shall have a minimum 95cm after 6 months. 138 Supplying and planting flower plants(Champa/ hybrid hibiscus/ Hybrid west Indian Jasmine/ Hybrid Plumeria white plant/ Panama yellow plant/ Oleander) healthy sapling having 10cm minimum height and shall have a minimum 25cm to 30cm height after 6 months. 139 Supplying and planting phylanthus healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 140 Supplying and planting bougainvillea colour flower plants healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 141 Supplying and planting song of India flower plants healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 142 Supplying and planting dracaena flower plants healthy sapling having 15cm to 30 cm height and shall have a minimum 60cm height after 6 months. 143 Supply and planting mexican grass including providing manure as directed. 144 PILE FOUNDATIONBoring 450 mm dia piles to any depthin any type of soil/ strata by anyapproved method, complete all as shown on drawings and as specified anddirected.Note:- The quoted rate shall include for mobilization and demobilisation of piling equipment, making approaches to site or point of pile boring if necessary. Nothing extra shall be paid on this account. 145 Boring for bored cast in situ pile 600 mm dia to any depth through any type of soil / strata, using DMC method (Direct Mud Circulation)and getting out & disposal of spoil to any distance outside of MD land , complete all as specified and as directedby the EngineerIn Charge 146 M & L Reinforced cement concrete of grade M-35 design mix (RMC) as per IS-456using 20 mm graded stone aggregate in cast in situ DMC bored pile of any length / any sectionscomplete all as specified and as shown on drg 147 M & L Reinforced cement concrete of grade M-35 design mix (RMC) as per IS-456using 20 mm graded stone aggregate in pile caps / grade beams complete all as specified and as shown on drg 148 Providing TMT bars (CRS/HCRM/CRM) in reinforcement 10 mm dia and over for bored cast in situ piles of any length and any dia all as shown on drgs including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with and including 0.9mm dia MS wire (annealed) or welding so as to secure the bar firmly in position/ required shape complete all as specified and shown on drgs (Fe-500D). 149 Providing TMT bars (CRS/HCRM/CRM) in reinforcement 10 mm dia and over for pile caps and grade beams, cut to length, bent to shape required, hooking ends and binding with and including 0.9mm dia MS wire (annealed) or welding so as to secure the bar firmly in position/ required shape complete all as specified and shown on drgs (Fe-500D). 150 All as per item No 13.136 here-in-before but5mm dia and over upto and including 10mm dia as in helicals for piles and stirrups for grade beams complete all as specified and directed. 151 M & L for providing PCC (1:4:8) type D-2 using 40 mm graded stone aggregate for concrete layer below pile caps foundation complete all as specified and directed. 152 Formwork to sides of pile caps/ grade beams and similar work, rough finished surface of concrete flat all as specified and as directed. 153 M & L for carrying out non destructive integrity test all as per IS 2911 (Part 4) 2013 for 600 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed all as specified and directed. 154 M & L for carrying out Initial Load test (vertical load test) cast in situ piles of 600 mm dia as per IS 2911 (Part 4) 2013 including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note :- Providing and installing test piles shall measured and paid separately) 155 M & L for carrying out Initial (lateral load test) cast in situ piles of 600 mm dia as per IS 2911 (Part 4) 2013including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note :- Providing and installing test piles shall measured and paid separately) 156 M & L for carrying out Initial load test ( pull outtest) of cast in situ piles of 600 mm dia as per IS 2911 (Part 4) 2013including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note :- Providing and installing test piles shall measured and paid separately) 157 M & L for carrying out Routine load Test (Vertical load)all as per IS 2911 (Part 4) 2013 for 600 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed 158 Testing of piles (Initial load test) for 450mm dia cast in situ bored piles all as per IS including removing the testing equipments from the site after testing is completed all asspecified and as directed
Contract Date : 23 Jul, 2025   |   Contract Value : 57.42 Crore
BRR : 9528620 Tender For Provision Of Cgsd (Kochi) At Willingdon Island, Kochi; 1 SCHEDULE A Part - I (BUILDING & STRUCTURE WORKS)Details of prepriced schedule is given in tender documents. 2 SCHEDULE A PART-II ( SITE CLEARENCE/DEVELOPMENT & EARTH WORKS) Details of prepriced Schedule is given in tender documents. 3 SCHEDULE A PART-III (INTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents. 4 SCHEDULE A PART-IV (INTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents. 5 SCHEDULE A PART-V (FIRE FIGHTING)Details of prepriced Schedule is given in tender documents. 6 SCHEDULE A PART-VI (ROAD/PATH/ HARD STANDING/CULVERT)Details of prepriced Schedule is given in tender documents. 7 SCHEDULE A PART-VII (EXTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents. 8 SCHEDULE A PART-VIII (EXTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents. 9 SCHEDULE A PART-IX (SEWAGE DISPOSAL) Details of prepriced Schedule is given in tender documents. 10 SCHEDULE A PART-X (AREA DRAINAGE) Details of prepriced Schedule is given in tender documents. 11 SCHEDULE A PART-XI (COMPOUND WALL) Details of prepriced Schedule is given in tender documents. 12 SCHEDULE A PART-XII (ORGANIC WASTE CONVERTER AND SMART ENERGY METER) Details of prepriced Schedule is given in tender documents. 13 SCHEDULE A PART -XIII (MISCELLANIOUS ITEMS) Note:- This schedule is not pre-priced by MES and the rate shall be quoted by the bidder. 14 INTERNAL WATER SUPPLY S & F for 15 mm dia bore CP two way bib cock with CP wall flange (Make : Jaquar Model No. OPP15041PM / Eqvlt in Kohler/Grohe), cast copper alloy, screwed down high pressure with crutch screwed both ends for CPVC pipes or for union and fixed complete all as specified and directed by Engr-in-charge. 15 S & F for 15 mm dia bore CP bib cock with CP wall flange (Make : Jaquar Model No. OPP15037PM / Eqvlt in Kohler/Grohe), cast copper alloy, screwed down high pressure with crutch, screwed both ends for CPVC pipes or for union and fixed complete all as specified and directed by Engr-in-charge. 16 S & F for 20 mm bore concealed Stop cock reqular brass body with spindle extnwith Exposed Part Kit of Concealed Stop Cock with Fitting Sleeve, Operating Lever & Adjustable Wall Flange (Compatible with ALD-083CQT & ALD-089CQT)(Make : Jaquar Model No. ALD 089 CQT/ Eqvlt in Kohler/Grohe), cast copper alloy, screwed down high pressure with crutch , screwed both ends for CPVC pipes or for union and fixed complete all as specified and directed by Engr-in-charge. 17 S & F for 25 mm dia bore concealed Stop cock reqular brass body with spindle extn with Flush Cock & Wall Flange 25mm Ceramic Disc Cartridge) with Plain Knob (Make : Jaquar Model No. ALD 081/ Eqvlt in Kohler/Grohe), cast copper alloy, screwed down high pressure with crutch, screwed both ends for CPVC pipes or for union and fixed complete all as specified and directed by Engr-in-charge. 18 S & F 20mm bore CP angular stop cock with CP wall flange (Make : Jaquar Model No. CQT 23053 / Eqvlt in Kohler/Grohe), cast copper alloy, screwed down, high pressure with crutch, screwed both ends for iron pipe or for union and fixed 19 S & F for 100 mm overhead shower rose round shape single flow (ABS Body chrome plated with gray face plate (Make : Jaquar Model No. 1989 with SHA 479L300S / Eqvlt in Kohler/ ESS ESS) with Shower Arm ø20mm & 300mm Long Round Shape with 90˚ Bend for Wall Mounted Showers with Stainless Steel connected to pipe complete all as specified and directed by Engr-in-charge. 20 COOLING APPLIANCESDesign, Supply, Installation, Testing and Commissioning of Invertor Type Floor Mounted Packaged AC Units including indoor and outdoor unit complete of specified capacities, combination of energy efficient Inverter compressor plus fixed compressors, nominal capacity condensing unit with all standard fittings, safety devices, like HP/LP cutout, single phase preventor, overload relays, R-410A Gas, vibration isolation pads etc. Suitable to work till 50 Deg ambient, Blue Fin Condensor and Corrosion Resistant Body, Wide Voltage Range 360V - 440V, The quoted rate shall include Group controller also asrequired for controlling AC from a single point and timer option for load sharing of AC units complete all as specified and as directed by Engineer - in - charge, of following capacities.Note: Design report shall be submitted before execution of work at site by the contractor to GE for his scruitiny/comments and further submitted to AO for his approval.Make: Blue Star/Daikin/Haeir/Godrej/Voltas/Equivalent. 21 a) 22 TR Inverter Package AC Units 22 b) 16.5 TR Inverter Package AC Unit 23 BLANK 24 BLANK 25 BLANK 26 Supply, Installation and Testing of Refrigerant pipingwith necessary clamping (suction & Discharge) Hard/Soft drawn Copper tube of suitable sizes, with copper elbows, tees, Tubular Nitrile Insulations etc as required complete all as specified and as directed by Engineer - in - charge. 27 S & F Control Cabling B/W Indoor & Outdoor units 28 M & L Refrigerant Gas - R410A 29 Supply, Installation and Testing of Hard PVC drain piping. Drain piping with Tubular Nitrile Rubber Insulation: complete in all respects, well clamped till drain Points complete all as specified and as directed by Engineer - in - charge. For All Units 30 DUCTINGSupply, fabrication, installation, testing of GI rectangular ducts, complete with all fittings such as tee, bends, special off shoots, inspection doors, transformation pieces etc. as required as per IS 655 including suspension and supporting arrangement for plenum, duct etc. required complete all as specified and as directed by Engineer - in - charge. 31 a) Using 0.63 mm (24 Gauge) GI sheet 32 b) Using 0.80 mm (22 Gauge) GI sheet 33 c) Using 1.00 mm (20 Gauge) GI sheet 34 DUCT INSULATION & LININGSupply and Installation of Acoustic Insulation of ducts using 9MM Open Cell Nitrile Rubber, well adhesived, 150 - 180 Kg/cm2 complete all as specified and as directed by Engineer - in - charge. 35 Supply, installation & testing of Thermal Insulation of ducts using 9MM Closed Cell Nitrile Rubber, well adhesived, 40-60 Kg/cm2 complete all as specified and as directed by Engineer - in - charge. 36 S & F Canvas Connection 37 AIR DISTRIBUTION PRODUCTSSupply and Fixing of Powder Coated Aluminium Grills/ Diffusers (Supply/ Return) complete all as specified and as directed by Engineer - in - charge. 38 S & F Collar Dampers 39 Supply and Installation of Fire Dampers complete all as specified and as directed by Engineer - in - charge. 40 Supply, Installation, Testing and Commissioning of Heater Bank Plus Humidistat Arrangement complete all as specified and as directed by Engineer - in - charge. 41 Supply and fixing, testing and commissioning water coolerhaving stainless steel body with inbuild purifier HIMA 7 NHC, dispencing capacity 125 ltr/hr and storage tank capacity 40 ltr normal and 40 cold electric driven (single phase), 230 volt, AC power supply with all connecting accessories complete all as specified and directed. 42 Supply and fixrefrigerator, electric driven (single phase), 220 V,50 HZ, capacity 195 Litres, 3 Star rated direct cool inverter, single door all as specified and directed by the Engineer-in-Charge. 43 Supply and install, testing and commissioning of split type air conditioner 1.5 TR Capacity of invertertechnology 5 star rating with cordless remote control single phase 240 volts complete with all accessories such as indoor and outdoor units and refrigerent tubing of adequete length as required at site indoor mounting plate, duly powder coated fixing with anchor bolts at any height, drain pipe of suitable size brought to ground level from any height, initial filling of refrigerent gas including making round hole on existing wall for taking up refrigerent tubing, drain pipe, cables, etc and making good the disturbed surface by matching with existing adjoining surface complete all as specified and directed (Cooling appliances- qty 4, Air conditioning- qty 10) 44 Supply and fix Voltage stabilizer 3 KVA for automatic operation, single phase naturally air cooled indoor type, wall mounted & designed for input variation between 170 V to 280 V with output voltage stabilized at 230 V with accuracy of ± 2.5% 45 Supply and fix Voltage stabilizer 4 KVA for automatic operation, single phase naturally air cooled indoor type, wall mounted & designed for input variation between 170 V to 280 V with output voltage stabilized at 230 V with accuracy of ± 2.5% (Cooling appliances-qty4, Air conditioning- qty 10) 46 AIR CONDITIONINGSupply and install,Testing & commissioning of split type air conditioner 2 TR capacity of inverter technology 5 star ratingwith cordless remote control, single phase 240 volts complete with all accessories such asindoor and outdoor units and refrigerent tubing of adequete length as required at site, indoor mounting plate, duly powder coated fixing with anchor bolts at any height, drain pipe of suitable size brought to ground level from any height, initial filling of refrigerent gas including making round hole on existing wall for taking up refrigerent tubing, drain pipe, cables etc and making good the surace by matching with adjoining surface complete all as specified and directed. 47 Supply and fix Voltage stabilizer 5 KVA for automatic operation,single phase naturally air cooled indoor type, Wall mounted type & designed for input variation between 170 V to 280 V with output voltage stabilized at230 V with accuracy of ± 2.5% 48 INTERNAL ELECTRIFICATIONS & F LED Mirror light 1 x 5W LUMOS ECCO 1 feet Make: Luker or Equivalent 49 S & F modular MCB DBOx 3 Pin Socket with MCB SP 20 Amp, 240 V including plastic enclosure as per manufacturer instruction fixed on wall surface complete for Air conditioner all as specified and as directed. (Make:-Havells, Model-DHDMCSN0251016 or equivalent) 50 Supply and fix Air circulator of 600 mm sweep AC single Phase. 230V, 1440 RPM complete all as specified and as directed. (Make: Havells model, Turbo Force Wall or equivalent) 51 S & FVertical triple pole & neutral (VTPN), double door, 16-way metallic modular distribution board conforming to IEC 61439-3, suitable for flush / surface mounting with provision for FPMCCB as incomer and TPN/SP MCBs as outgoing, reversible metal door, 200 A copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wiriest & cable ties for cable management, profited masking sheet, etc. having IK 09 & IP 43 protection complete all as specified and directed. 52 S & FVertical triple pole & neutral (VTPN), double door, 4-way metallic modular distribution board conforming to IEC 61439-3, suitable for flush / surface mounting with provision for FPMCCB as incomer and TPN/SP MCBs as outgoing, reversible metal door, 200 A copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wiriest & cable ties for cable management, profited masking sheet, etc. having IK 09 & IP 43 protection complete all as specified and directed. 53 M & L for Flame ProofMCB Distribution board SPN 12 way, with case iron body, powder painted, with 100 Amps rated bus bar etc. including provision of one 32 Amps SPN MCB as incoming and 6 Amps SP MCB -10 Nos as outgoingcomplete all as specified and as directed. 54 M & L for Flame ProofMCB Distribution board SPN 8 way, with case iron body, powder painted, with 200 Amps rated bus bar etc. including provision of one 32 Amps SPN MCB as incoming and 6 Amps SP MCB- 6 Nos as outgoingcomplete all as specified and as directed. 55 Supply and fix Engage light with Green & Red LED complete all as specified and as directed 56 Supply and fix of CS mounted high intensity LED search light, long range, manually swivel in all direction, 250 W, minimum range 700 meters, Single, LED Efficiency> 140 lm/w, PF> 0.95, CCT 5500K - 6500K, Optical grade PMMA/PC lens/reflector efficiency>95%, multiple circuit to avoid complete run down, anti UV, narrow beam 5 degree, die cast LM6 body with air fins, powder coated, constant current, an average lux at 10 meter - 8000 lux with circle of approx 600 mm, working temp: -20 to +60 degree C, input Volt 100-300 VAC, 50 Hz, PF >0.95, IP-66, confirming to LM79/ LM80 and type tested as per IS: 10322/ IS: 13383, BIS approved and Govt lab tested for lux intensity. The search light is completed with manual revolving CS stand D20cm x H15cm (min.) with 3 nos. foundation holes for mounting of searchlight on watchtower structure, manual rotation of light on horizontally 360 degree with 45 degree tiltable with provision of both instant locking arrangement at desired position. Model No. CS-LRFLL-25PC25 of KALIN make or equivalent 57 Supply, install, testing and commisisong of outdoor floor/wall mounted thermoplastic polycarbonatefeeder pillar panel, Enystar EmptyEnclosures, IP-65, weatherproof, corrosion free, Halogen and Silicon Free, Frame retardant with Opaque Lid Size-[276 x 546 x 186]mm and Transparent Hinged Lid, completed all as specified and directed. 58 M & L for TV socket module metal flushed including flushed Box cover plate Box for 2 way module complete all as specified. 59 M & L for telephone jack with module metal flushed including flushed Box cover plate Box for 2 way module complete all as specified. 60 Supply and lay coaxial cable for TV Cabledrawn through conduit 61 S & F flame proof exhaust fan 300 mm sweep, single phase, 1440 RPM complete all as specified and as directed. 62 FIRE FIGHTINGSupply and fix Foot Valve conforming to IS 4038, 100 mmdia. 63 Supply and fix Foot Valve conforming to IS 4038, 150 mmdia. 64 Supply and fix Cast Iron Air Valves with single air Outlets, conforming to IS 14845 of size 100 mm dia bore and fixing up in Cast Iron Water supply mains of size 100 mm dia. 65 S & F sprinkler flexible drop pipe 1 mtr long. 66 S & F sprinkler rossette 25 mm dia. 67 Supply and installation, testing and commissioning of Analog Addressable type Active Loop Repeater (Loop power/external power) Fire terminal with inbuit turbo isolator, Backlit LCD Display 6x40 characters display, having Controls For Reset, Mute, Accept, Silence alarms and Self Test, with programmable free keys and Duly Approved byEN54/LPCB/VDS/FM Make: SIEMENS/NOTIFIER/BOSCH 68 M & L for Low smoke Zero helogen flame retardent fire alarm cable2 core, 1.5 mm² copper conductor confirming to BS7629-I, BS6387 & rated for 500 v grade having plaine sraded copper coductutor with priming insulation of glass mica fire resistance tape & secondery insulation of high performancesilicon rubber with electrostatic screen of aluminium fire barrier Type LT53 outer sheath confirming to BS 7655, red in colour drawn through & including concealed steel conduit including laying,fixing,connecting complete all as specified and directed. 69 Staircase signage down of make bajaj cat part no. 111499 model no. DSDWBB 3W double side display for staircase downwards (with 2 hours built in battery backup) complete all as specified and directed at site complete all as specified and directed. 70 S & F wall mounted LED emergency Exit signage luminaire Lit up using regular mains supply comes with a unique rechargeable Ni-Cd battery capable of emergency back up upto 05 hours(Cat No. 220211 Make Bajaj or equivalent to CG/Havells. 71 Supply, Installation, test and Commissioning CPRI APPROVED factoryfabricated, indoor type, LT panel board , made out of 2 mm thick CRCA Sheetsingle door withboth side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embeddedwith 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete withinternal connection with suitable size of cable, cable lugs and cable glandsPCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Testing after Installation includingcomplete all as specified and comprising of the following:- Make of MCCB/MCB -MDS/LEGRAND/L&T/HEGGER (Main Fire Fighting Panel)INCOMING(i) MCCB 4 Pole 400 amp 50 Hz, 415 V with rupturing capacity 35 KA with microprocessor based release - 01 No.(ii) Voltmeter Digital type 0-500 Volts range flush type with selector switch- 01 No.(iii) Aluminium Bus bar TPN - 600 amps- 1setOUTGOING(i) MCCB 3 Pole 200 amp 50 Hz, 415 V with rupturing capacity 35 KA with microprocessor based release- 02 No.(iii) MCB TPN 32 Amp - 03 Nos.(iv) 80 HP S/D soft STARTER- 02 Nos.(v) DOL STARTER 7.5 HP- 02 Nos.(vi) Motor Protection Relay32-88 amps- 2 nos. (vii) Motor Protection Relay2- 5.5 amps- 2 nos. (viii) On/Off/Trip Indication Lamps, 220 V AC- 6 nos.(ix) Start/Stop Push Button, 4 Nos. (x) Phase indicating lamps RYB for incoming and each outgoing connection.(xi) Digital type Ammeter 0- 150 amps with selector switch and CT coils of suitable capacity for incoming and each outgoing connection- 1 no. 72 M & L for coating and wrapping of under ground steel pipe buried in soil shall have protection against corrosion as per IS-10221.The coating and wrapping shall be carried out in systamatic manner to get uniform thickness of coating as per IS specification 73 Supply, Installation, test and Commissioning CPRI APPROVED factoryfabricated, Indoor type, LT panel board, made out of 2 mm thick CRCA Sheetsingle door withboth side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embeddedwith 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete withinternal connection with suitable size of cable, cable lugs and cable glandsPCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Testing after Installation includingcomplete all as specified and & directedby Engr-in-charge comprising of the following :– ( Booster terrace pump panel)INCOMING:-(a) INCOMING MCCB 40 A 25 KA, 4 POLE- 01 No.(b) Busbar TPN of size 100 apms - 1 setOUTGOINGS:-(a) MCB 3 POLE TPN 32 Amps,10 KA-2 Nos.(b)DOL Starter for 7.5 HP Pump set-1 Nos.(c) Ammeter Class-1, digital panel mounting type 96mmx96mm L & T cat no WDS301FCA00 including CT 50X5 Amps 3 nos & selector switch-4 nos(d) Voltmeter Class- 1, digital panel mounting type 96mmx96mm L&T CAT NO.WDS301FEV00 & selector switch - 1 no.(e) LED TYPE indicator lamp 1 set (set of three for R,Y,B)(f) Mini protecrionRelay 4-11 amp - 1 nos. 74 Fire Extinguisher mechanical Foam type trolly mouted of 9 Liters capacity. Ceasefire 9 litrs fire Extinguisher AFFF Foam type, External Cartridge type, Pressure Guage Gross weight 14.6 Kg, empty weight5.6 Kg, Can height 611 MM, Diameter 175 MM, Discharge time less than 60 Secs controllable discharge mechanism, Minimum 6 Mtrs, Applicable on Class A, B, can construction deep down & CO2 Mig welded Valve Construction: Forging & Machining, Internal coating of can: Epoxy powder coating, External coating of can: Epoxy poyster powder coating sheet metal thickness 2.0MM,1 year warranty. Make Cease Fire Or Equivalent. (pol store) 75 Supply, Installation,Testing & commissioning of Carbon Dioxide (Co2) type fire extinguisher of 4.5 Kg confirm to IS: 15683, with ISI marked/TAC approved fitted with required accessories including wall suspension brackets. 76 Supply, Installation,Testing & commissioning ofDRY CHEMICAL POWDER (ABC) stored pressure type fire extinguisher of 6 Kg confirm to IS: 15683, with ISI marked/TAC approved fitted with required accessories including wall suspension brackets. 77 Supply and fixing single unit flame type detectors (Triple IR infrared flame detectors) Addressable type Flame detectors with UV/IR detection capacity (add up cost of module to be a complete set, the type of module shall be relaying type module) complete all as specified and directed 78 Supply and fixing,Test and Drain valve 65/50mm, forged brass body, brass chrome plated ball, 304SS stem with Polycarbonate sight glass, indicator and handle made of steel complete all as specified and directed 79 SPECIAL EQUIPMENTS FOR STORESDesign, manufacture, Supply, installation, testing and commissioning of Automated Storage and Retrieval System with storage racks, pallets, stacking crane, computer hardware with compatible inventory software as a turnkey solution complete all as specified and directed. Automated Storage and Retrieval System shall consist of computer controlled & PLC stacker crane driven system for automatically placing & retrieving materials from defined storage locations. The crane shall be capable of lifiting, stacking and retriveing the pallet loads weight upto 1125 Kg (max) complete all as specified and directed by the Engineer-in-Charge. Technical data for design of heavy duty ASRS:-(a) Dimensions:-Height:10 Mtrs for racking system which shall be designed and constructed to store the required no. and size of pallets.(b)Storage capacity:-Pallet Size: 1300 (W) x 1200(D) x 1250 (H) in mmPallet Nos.: 480Pallet load capacity: 1125 KgTotal capacity: 540 Tons(c) Stacker Crane: Double mast automated stacker crane for handling Pallet, size 1300mm(W) x 1200mm (D) x 1250mm (H) and pay load (including Pallet self weight) of 1125 Kg max. The stacker crane shall be capable of picking up the pallet from in-feed conveyor or loading station and stacking it into empty slots of racking system. Similarly, it shall also be capable of retrieving the palltet from racking system and putting it on the same conveyor or unloading station. Stacker crane will be mounted on rails at the bottom to traverse the length of the storage system. Top rails mounted on the racking system shall also support it. PMDC motars should be used with required counter weight for better efficiency of verticle travel.General technical parameters of stacker crane:Technical parameters/Type- Double Mast(i) Operation mode (Networking)- On-line automatic / Single automatic (Ground/Boarding) /Manual operation (Boarding) / Maintenance (ii) Communication Means- Wireless 80 (iii) Power supply mode- 380 to 415 V, 50 Hz, three phase five wire (iv) Addressing mode- Horizontal and verticle operation: photo electrical sensor + bar code scanners(v) Positioning / Reduction accuracy (mm) level- lifting ± 3 - 5, Fork : ± 3(vi) Fork unit- 1 Double deep fork(vii) Load unit- MS Pallet (viii) Total Height- 10 Mtr(ix) The normal lifting speed (m/min) - 10 MPM(x) The normal running speed (m/min) - 65 MPM(xi) Rated load- 1125 Kg(xii) Receipt equipment fixed platform/conveyor/lifting /platform(electric/manual)- Conveyor(d) Pallets: to stack and retrieve the pallet weighing up to loaded pallet weight 1125 Kg at height up to the last loading level in the racking system. It should have retrieval mechanism to enable stacking & retrieval of pallet from either side of the rack and also to pick up the load directly from the loading station.Pallet Details:-(i) Dimensions - 1300mm(W) x 1200mm(D)(ii) Pallet height- 1250 mm(e) Racking system:- Two single aisle having two row racking system each with 05 verticle levels for storage of material. Racking for double deep type storage of 480 Pallet of size 1300mm(W) x 1200mm (D) x 1250mm (H). Loaded pallet weight: Pay load with pallet 1125 Kg max. System details:-Working aisle -01 Nos. (Double deep)Store rack -24 Nos./RowTotal rack in 1 aisle-24 (Left) + 24 (Right)= 48 Nos.No. of level- 5 Nos/RackTotal Pallet-48 x 5 x 2 = 480 Nos.Load capacity- 1125 Kg/LevelDouble mast stacker crane-01 No. 81 (f)Aisle Equipment:-This will consist of electrical as well mechanical aisle equipments and willl be designed as per the pallet requirement. The mechanical Aisle equipment of bottom rail shall consist of I Beam and will be provided with adjustable calmps for holding the rail in position to ensure proper alignment. Top rail shall be mounted on the racking. The electrical aisle equipment shall consist of power rail (fully enclosed bus bar having 7 pole system), which is mounted on the racking system below the first loading level.(g) Details of rack members:-The racking system shall consist of cold-rolled steel sections as per manufacturers design to accommodate and store pallets and connected systems.(h) Loading- unloading station/ Conveyor(i) Pallet Load 1125 Kg max.(ii) Bearing- SKF Equivalent make(iii) Motor- Seimens/Sew Euro Drive/Nord Sew/ Bonfiglioli or equivalent(iv) Gear Box- Bonfiglioli Make or equivalent(v) V.F.D.- Yashkawa make or equivalent(j) All steel surface shall be powder coated finish with 8 tank treatment process.(k) Maintenence: The annual maintenence of complete ASRS system during the defect liability period of two years shall be included in the rate quoted for the system and the AMC contract duly signed with the manufacturer of the ASR system shall be submitted at the time of handling over the system. The AMC shall include all spares and consumables etc required during the period of two years and nothing extra shall be paid on this accountNote- 1)Mechanical safety provision (i) End of aisle shock absorbers / bumpers for stacker crane.(ii) End of travel buffer for the lifting crane.(iii) Safety catches on lifting carriage.(iv) Anti-tilt mechanism for the stacker crane. An additional antifall device must be provided for the lifting carriage. In the event of electromagnetic break motor failure or malfunction, this device should automatically engage to safely hold the carriage and prevent any freefall, thereby avoid accidents due to emergency brake failure.(v) Continuous rail cleaning brush for floor rail.(vi) Adjustable rail clamp to ensure alignment. 82 (vii) Resilient rubber pads on adjustable clamps for vibration dampening.(viii) Profile check on lifting carriage to check all three dimensions (width, depth & height) of the pallet. Note - 2 Electrical safety provision (i) There shall be Emergency stop push button at all panels and stations.(ii) Optical light beam amd mechanical safety sensor to stop the operation in case of improper storage.(iii) Back up circuitry for proper system operation.(iv) An electromagnetic brake shall be used to avoid the slippage of the hoist.(v) Stopper shall be provided for the maintenance door.(vi) Load cells shall be provided for the over weight of tray.(vii) Automatic door shall be provided for operator safety while machine in operating condition.Note - 3 Physical safety provision (i) The ASR system shall comprise of safety fences having grid size of max. 40 x 40mm & wire dia should be of min. 3 mm. Height of the fencing should be minimum 2.0 meter.(ii) One No. of electromagnetic aisle access door shall be provided. It should cover the complete length of the system on one side.(iii) A manual locking system to restrict the movement of unauthorised personnel shall be provided.NOTE: 1) Design report shall be submitted before execution of Work at site by the contractor toGE for his scrutiny / comments and futher submitted to AO for obtaining approval. Item No. 13.070 below shall be compatible with this item/ system and both should be integrated. Changes in make of different components of ASR system and minor changes in different parameters are permitted with approval of Accepting Officer as per recommendation of ASR system manufacturerprovidedthe end objective of the system is complied.2) The ASR system is to be installed in Bulk store house complex. Necessary civil works for installation of the ASRS required in the building is included in the scope of this item. Neccessary arrangements for integration of system with flooring and overhead trussess of the building shall be done at appropriate stage and shall be included in the rates quoted3) The PLC program backup for the ASRS and Advanced Inventory Management System shall be provided in an editable format. The WMS program shall be provided along with its source code to enable the user to perform maintenance, modifications and future upgrades as part of the project acceptanceMake of ASR system:Armstrong Ltd/ Godrej Koerber/ Kardex India storage solutions Pvt Ltd/ Daifuku India Pvt Ltd/ Addverb technologies Ltd/ Craftsman Automation Ltd/ Tech-mark 83 Supply, installation, testing and commissioning of Advanced Inventory Management System with compatibile computer hardware and integrated inventory and weight management system with PLC based software complete all as specified and directed by the Engineer-in-Charge. Technical specification of the system(i) System Height(Min) : 6400 (±100) mm(ii) System Width(Min) : 3150 (±100) mm(iii) System Depth(Min) : 2300 (±100) mm(iv) System Base(Min) : 7.24 Sq.Mtr(v) Tray Int. Size(Min): 300 (H) x 2450(W) x 500 (D) in mm(vi) Tray dead weight(Min) - 57 Kg (Approx.)(vii) Per tray weight capacity - 300 Kg(Min)Technical specification of the system:-(viii) Tray Quantity : 32 Nos.(ix) Usable net load - 9.6 ton(Min)(x) Storage surface area per system - 39.2 sq mtr(Min)(xi) Door - Automatic, (xii)Power supply - 440V, 50/60 Hz, 3 Phase(xiii) Motor 3 Phase 1440 RPM - Seimens make or equivalent(xiv) Chain - Diamond makeor equivalent, (xv)Bearing - SKF/NTN make or equivalent(xvi) External cladding - Epoxy powder coatedSafety Features:1. Photo curtain at access port, 2. Motor Protection relays, 3. Limit switch at door, 4. Single phase preventer,5. Switch mode power supply, 6. 15 Min battery backup for PLC, 7. Noise less than 60db, 8. Emergency stop various safety alertsNote: 1) The system and software provided under this item shall be of same make as for item 13.066 to 13.069 or a compatible system and software as recommended by the chosen manufacturer of ASR system. This system shall be integrated with ASR system.2) Comprehensive maintenance of the system during two years of defect liability period shall be a part of this item and rates shall be quoted accordingly. Comprehensive maintenance shall include all spares including software update. The ASR and advanced management system shall be operated by single warehouse management system.3) The PLC program backup for the ASRS and Advanced Inventory Management System shall be provided in an editable format. The WMS program shall be provided along with its source code to enable the user to perform maintenance, modifications and future upgrades as part of the project acceptance 84 Supply, installation and testing of Car Traffic Boom Barrier 6 mtr suitable to working on power supply 230 Volt, 50 Hz, 24V DC electric motor, adjustable with CAMS, operating ambient temperature from -20 to +55 Degree Celsius, uses cycle 2000/Day, air cooling, type of beam is rectangular with skirt, effective torque 280-290 Nm open/close time 2 to 4 Sec complete all as specified and as directed by Engineer-in- charge.Make: FAAC/Parkilo/Skidata/BFT 85 EXTERNAL WATER SUPPLYSupply and fix Foot valve conforming to IS, 100 mm dia complete all as specified and directed. 86 Supply and fix Cast iron air release valve with 100 mm bore and two outlets as per IS:14845 complete all as specified and directed. 87 Supply, installing, testing and commissioning of electrically driven horizontal Centrifugal Pump set 9.0 LPS at 50 Meter Head as per specification, motor TEFC type, 2880 rpm, 415 V, 50 Hz, 3 phase, class F insulation, IP 55 protection, starting on suitable Star Delta starter. The pump shall be horizontal, end suction, top discharge. The pump shall have cast iron casing, cast iron/bronze impeller (as per manufacturer), carbon steel shaft with common base frame (fabricated mild steel channel frame or cast iron type) placed on RCC (1:2:4) including foundation, bolts, nuts etc. complete with antivibrator pad as required capable of discharging not less than 550 LPM at 45 mtr head inclusive of suitable rated three phase starter as recommended by the manufacturer, PVC insulated copper cable connection from starter to the motor terminals all as specified and directed by the Engineer-in-charge.(01 No. Working + 01 No Stand By)Make:- Kirloskar Brothers/Crompton or equivalent. 88 Supply, install, test and commissioning of LT Panel, indoor type, powder coated, 2.0 mm thick CRCA Sheet, CPRI approved having, IP 43, MS angle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with Horizontal copper bus bar for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 2.0 mm thick CRCA Sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables. Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, track resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. andcomprising as under: LT Panel for Pump House. The LT Panel comprising of the following:- 89 Incoming:-MCCB, thermal magnetic release, 4 pole, 415 Volts, 100 Amps, breaking capacity 36 KA- 01 No. Ics =100% IcuMetering Unit:- (a) R Y B Indications (LED Type)- 01 sets(b) Digital Multi function meter - 01 No.(c) CTs - 100/5A, CL-1, 15 VA - 01 set(d) Horizontal Aluminium busbar for 3 phase, 440 volts, 50Hz, 4 wire system of rating 350 Amps for phase and 350 amp for the neutral barOutgoing:-(a) MCB, TPN 40 Amp, 415 Volt, C Curve - 03 Nos.(b) Star Delta starter 12.5 HP, 3 Phase, 415 Volt- 02 Nos.(c) Digital ammeter - 2nos.(d) Single Phase Preventer - 2 nos. 90 M & L Valve chamber of internal size 0.90m X 0.90m X 0.90m (internal dimensions) including excavation of earth work in any type of soil, 150mm thick PCC in 1:4:8 type D2 foundation, brick work in CM 1:6, 15 mm thick rendering in CM 1:4 to internal surfaces and external surfaces upto 150mm depth below GL, PCC 1:3:6 type C1 as in coping, cover with two Nos. of hinges and one No. handle made out of MS round bar 10mm dia with necessary locking arrangement including painting to the steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer complete all as shown on drg and as specified. Note:- The quoted rate shall include all earthwork and connected items. 91 M & L Earthing complete with Galvanized steel earth plate electrode of size 600mmX600mm, 6.00 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below the normal ground level with top edge of the plate not less than 1.5m below normal GL and connected to galvanized iron strip of size 32 x 6 mm size by means of bolts, nuts, check nuts and washers of galvanized iron steel all as shown in Electrical Plate No. 3 connecting to earthing test point, including necessary earth work in any type of soil, PCC earth chamber made in PCC 1:3:6 type C1 (using 20mm graded aggregate), common salt, charcoal, CI funnel, earth pit cover in RCC 1:2:4 type B1 (using 20mm graded aggregates), with 8mm CTD bars @ 100mm c/c in both ways, including necessary form work complete including necessary test on completion all as specified and as directed. 92 EXTERNAL ELECTRIFICATIONM & L for HT/LT MS cable route indicator, engraved the description on the disc not less than 6 dia welded with 40x6xmm MS strip of approx length 90 cm duly painted on the steel parts as per colour code and provision of PCC 1:4:8 type D-2 using 40 mm grade stone aggregate of not less than 0.05 cum in each at base under the ground including necessary earth work and formwork complete all as specified and directed.Note: HT route indicator shall be painted as under:-(i) For HT 11 KV cables - “BROWN”(ii) For LT cables - “BLUE” 93 Supply and fix compact air insulated bus bar trunking system with copper busbar 1600 Amps, 50 KA breaking capacity, IP54 protection, bus duct 1600 A, 415 Volt, capacity sandwich type, Set RYBN complete with accessories such as flange ends, vertical bends, supporting brackets etc from transformer to LT panel board complete all as specified and directed. 94 Supply, install, testing and commissioning of Distribution transformer step-down Level 2 (Previously EE Level 3 before Amendment No 4 to IS 1180), 11KV / 0.433KV, Three Phase complying withIS: 1180/IEC-76(Part-1) 2014 with latest amendments, indoortype double copper wound suitable for 50 Hz system of capacity 800 KVA, oil immersed naturally cooled delta connected on HT side and Star connected on LT side, Vector Group Dyn11, provided with OFF load tap changer to vary secondary voltage from -7.5% to + 7.5 % in step of 2.5 %.Losses should be confined to the limits specified as follows: maximum allowable losses atfull load (100 %) & Half Load (50 %) shall not be exceeded 5838 watts & 2147 Wattsrespectively as per GRlHA RATING, Percentage Impedance: 4.5%. Losses and Impedance are subjected to tolerance as specified in IS 1180. The transformers should be supplied with first filling of oil confirming to IS 335. The transformer should have both side cable end box with neutral brought out complete all as directed by Engineer - in -Charge, and installation of transformer shall be carried out as per IS-10028and comprising with the following standard fittings/Technical specifications:-(a) Lifting lug for transformer and tank.(b) Earthing terminal rating and diagram plate.(c) Air release device.(d) Oil filling inlet pipe with plug.(e) Drain outlet pipe with brass gate valve.(f) Conservator tank with oil level indicator(g) Silica jel breather(j) First fill of oil upto level including conservator tank with fresh new oil conforming to IS335.(k) Type of connection Delta/Star(l) Type of cooling: Oil and Natural Air.(m) Vector group: DYN 11.(n) Temperature rise over an ambient of 50 °C maximum.(o) Cable end box on both side for HT/LT cables of suitable size.(p) Provision of thermometer with pocket.(q) Provision of oil and winding temperature gauge. 95 Supply, install, test and commissioning of LT Panel, Indoor type, powder coated, 2.00 mm thick CRCA Sheet, CPRI approved having, IP 43, MSangle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply,bus bar chamber with Horizontal copper bus bar for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air.The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 1.6 mm thick CRCA Sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables. Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, track resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. andcomprising as under: The LT Panel comprising of the following:- Main LT PanelHorizontal copper busbar for 3 phase, 440 volts, 50 Hz, 4 wire system of rating 1600 Amps for phases and 1600 Amps for Neutral. 96 Incoming:-Incomer:-ACB 4 Pole, 415 V, 50 KA with Thermal Magnetic Release (Manual Draw out type) of capacity 1250 AmpMetering Unit:- (a) R Y B Indications (LED Type)- 1 sets(b) Digital Multi function meter - 01 No.(c) CTs - 1600/5A, CL-1,15 VA - 1 setOutgoing:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 630 Amps, Ics =100% Icu, breaking capacity 35 KA, Ics =100% Icu- 02 No. (For DG AMF Panel & Spare)(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 400 Amps, Ics =100% Icu breaking capacity 36 KA- 02 No. (for APFC Panel & FPB 2 Near bulk Store) (c) MCCB, thermal magnetic release, 4 pole, 415 Volts, 320/315 Amps, Ics =100% Icu breaking capacity 36 KA- 01 No. (for FPB 1 Near Adm Block) (d) MCCB, thermal magnetic release, 4 pole, 415 Volts, 200 Amps, Ics =100% Icu breaking capacity 36 KA- 01 No. (for Existing Load)(e) MCCB, thermal magnetic release, 4 pole, 415 Volts,125 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for FPB 3 Near Auction Disposal Store)(f) MCCB, thermal magnetic release, 4 pole, 415 Volts, 32 Amps, Ics =100% Icu breaking capacity 25 KA- 03 No. (for MT Complex, Watch tower no 2, Guard room)(g) Digital Ammeter with suitable CT for each outgoing 97 Supply, install, test and commissioning of LT Panel, outdoor type, powder coated, 3.00 mm thick CRCA sheet, CPRI approved having, IP 54, MS angle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply,bus bar chamber with Horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 2 mm thick CRCA sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables. Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, crack resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. Feeder Panel No.1 (Near Admn bldg) 98 Horizontal Aluminium busbar for 3 phase, 440 volts, 50Hz, 4 wire system of rating 600 Amps for phases and 600 Amps for Neutral.Incoming:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 400 Amps, breaking capacity 36 KA - 01 No. Ics =100% IcuMetering Unit:- (a) R Y B Indications (LED Type) - 1 sets(b) Digital Multi function meter - 01 No.(c) CTs - 600/5A, CL-1,15 VA - 1 setOutgoing:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 200 Amps, Ics =100% Icu breaking capacity 36 KA- 02 No. (for 2nd floor & spare)(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 160 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for 1st floor)(c) MCCB, thermal magnetic release, 4 pole, 415 Volts, 63 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for G floor)( d) Digital Ammeter with suitable CT for each outgoing 99 Supply, install, test and commissioning of LT Panel, outdoor type, powder coated, 3.00 mm thick CRCA sheet, CPRI approved having, IP 54, MSangle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply,bus bar chamber with Horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air.The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 2 mm thick CRCA sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables.Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, crack resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. Feeder Panel No.2 (Near Bulk Store) Horizontal Aluminium busbar for 3 phase,440 volts, 50Hz, 4 wire system of rating 600 Amps for phases and 600 Amps for Neutral. 100 Incoming:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 400 Amps, breaking capacity 36 KA - 01 No. Ics =100% IcuMetering Unit:- (a) R Y B Indications (LED Type)- 1 sets(b) Digital Multi function meter - 01 No.(c) CTs - 600/5A, CL-1,15 VA - 1 setOutgoing:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 200 Amps, Ics =100% Icu breaking capacity 36 KA- 02 No. (for Equipment Load & spare)(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 125 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for Bulk Store)(c) MCCB, thermal magnetic release, 4 pole, 415 Volts, 32 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for Watch Tower No. 1)( d) Digital Ammeter with suitable CT for each outgoing 101 Supply, install, test and commissioning of LT Panel, outdoor type, powder coated, 3.00 mm thick CRCA sheet, CPRI approved having, IP 54, MSangle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply,bus bar chamber with Horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 2 mm thick CRCA sheet, duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables.Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, crack resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. Feeder Panel No.3 (Near Auction Disposal Store) 102 Horizontal Aluminium busbar for 3 phase, 440 volts, 50Hz, 4 wire system of rating 200 Amps for phases and 200 Amps for Neutral.Incoming:-(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 125 Amps, breaking capacity 25 KA- 01 No. Ics =100% IcuMetering Unit:- (a) R Y B Indications (LED Type) - 1 sets(b) Digital Multi function meter - 01 No.(c) CTs - 200/5A, CL-1,15 VA - 01 setOutgoing:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 100 Amps, Ics =100% Icu breaking capacity 25 KA- 02 No. (for Store Dispatch Complex & Spare)(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 32 Amps, Ics =100% Icu breaking capacity 25 KA- 03 No. (for Pol store, Auction disposal store, Covered Hard Standing)(c) Digital Ammeter with suitable CT for each outgoing 103 Supply and fixing poly carbonate street light junction boxes IP 66/67 Weather proof suitable for outdoor installation having minimumsize255 x 355 x 122 including suitableCable connecting Terminals, Cable lugs, including provn of one No. MCB SP 6 Amps for operating the street light fittings, Suitable Cable Glands as per site requirement, all as directed by the Engineer-in-Charge. 104 S & F Street light bracket made out of GI tubing 32/40 mm dia, light grade of length1.2 mtr long bend to shape suitable for security light fitting with necessary MS clamp-02 Nos with one coat of anti corrosive primer and two coats of aluminium paint including nut, bolt, washers and 3 core FRLSinsulated sheathed, multistranded copper conductor of size 1.5 sqmm for phase and neutral and 1.5 sq mm for earthing drawn throughthe poles for connection from junction box to light fitting complete etc all as specified.Note: Phase should be Red/Yellow/Blue, neutral should be black and earthing wire should be green in colour. Two runs of cable for phase and neutral and one run of cable for earth will be measured and paid as one unit length. 105 Supply and fixing of LED flood light, 200W, watt 230 V, AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp and made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP protection incl system efficiency >110/120LPW 10KV SPD included Energy saving, environmental friendly and general purpose lighting complete all as specified and directed Engineer-in-Charge. Make : Make : Crompton/Philips/Wipro/Bajaj 106 Supply and fix High Mast Panel outdoor type, suitable to take load up to 6 KW, Conforms to IS/IEC 60947-4-1, Provided with Protection Degree IP 54, Extended wide band (150 Vac - 300 Vac) coil, FRLS (Fire retardant low smoke) Internal wiring, In-built Short-Circuit Protection, Class H Insulation, 3 Phase 415 Volts AC with the following accessories:Phase : 3 Phase, 415 VoltsMax Load Capacity : 6 KWTimer type: AstronomicalContactor Rating : 32 A TPMCB Rating : 63 A TPNMake : Crompton/ Philips/Wipro 107 Supply and laying DWC (Double wall Corrugated) duct pipe outer dia 63 mm and inner dia 50 mmconforming IS 16205 (Part 24 ) for protection ofelectric cable complete all as specified and directed. ( for 10 sqmm St light cable & 16 Sqmm cable) 108 AVIATION OBSTRUCTION LIGHTSupply and fix aviation obstruction light integral aviation light comprising of aluminium housing with polycarbonate enclosure, 240 volt with timer switch and one No.10 A, MCB, SPN 230 V with fixed enclosure complete all as specified and directed by Engineer-in-charge.Make:- Bajaj cat No BGAV 302 LED or equivalent in Philips/Crompton/Surya 109 INCINERATORSupply, fixing and testing and commissioning of Solid waste Electric Incinerator, single chamber type having a combustion chamber supported with electric coil for generating sufficient heat to burn 100Kg/hr solid waste, retains and re-burns the exhaust gases for minimum of 2 seconds at 850°C, Stainless steel stack for longevity, fitted with a Velocity Cowl as standard, Chamber designed for maximum air flow and circulation which in turn improves efficiency and total burn time, easy to open and close loading door, designed to increase operator safety, steel cladding to reduce risk of infection and increase longevity of system with working temperature not less 450 degree Celsius mounted on foundation as recommended by OEM including electrical control panel with suitable size MCCB, relays & contactor recommended by OEM complete all as complete all as specified and directed.Note:(a) The electrical works including electrical LT panel, internal wiring of the LT panel, suitable size copper wires from panel to Solid waste Electric Incinerator as recommended by OEM to operate the Solid waste Electric Incinerator of capacity 100 Kg/Hr to make Solid waste Electric Incinerator operational is deemed to be included in the rate quoted. (b) All Electrical works shall be carried out as per relevant BIS/lS equivalent standard norms only and also in accordance with the latest edition of the Indian Electricity Act / rules formed there under and as amended from time to time.(c) Any other works (mechanical, electrical & Civil) connected to installation, testing & functional requirement of Solid waste Electric Incinerator of capacity 100 Kg/Hr all as mentioned above and which is not mentioned or included in this Schedule but required at site necessary shall be carried out by the contractor and quoted rate shall deemed to included for the same.(d) Foundation/Plinth/Base: shall be provided as per manufactures recommendations, however minimum 0.5m space should be available all around the Solid waste Electric Incinerator and height of plinth shall not be less than 0.5 MMake: Precitech thermal Pvt. Ltd., Rram Buisiness corp, Alfa therm Ltd., Thermax Ltd, Kanti Industries, Fortec 110 Supply & fixing MCCB, thermal magnetic release, 4 pole, 415 Volts, 200 Amps, breaking capacity 36 KA- 01 No.Ics =100% Icu with Sheet metal enclosures fixed properly at directed location and connecting/testing complete all as directed. 111 ELECTRIC SIRENSupply and fixing Sirens Electronic type Horizontal Double Mounting Three Phase 400/440V, 2800 RPM 50 C/s Flame Proof, audible range 3.5 Km, 2 HP, continuous normal operation for at least 50 minutes with on/off system complete all as specified and directed. 112 Supply and fix advance Sirens controller Electronic type suitable to operate on 3 phase, 415 volt AC 50 Hzcomplete all as specified and directed. 113 Supply & fixing MCCB, thermal magnetic release, 4 pole, 415 Volts, 63 Amps, breaking capacity 25 KA- 01 No.Ics =100% Icu with Sheet metal enclosures fixed properly at directed location and connecting/testing complete all as directed. 114 SOLAR POWER PLANTDesign, supply, installation testing and commissioning of roof top solar photovoltaic power plant (ON-GRID) on roof top of existing bldg of capacity 150 KWp, power evacuation at 415 Volt 3 phase system all as per guidelines/norms issued by MNRE & Indian Metrological Deptt approved Solar Radiation Data viz Direct Normal Irradiance, Global Horizontal radiance etc complete comprising with the following Solar Photo Voltaic Plant.(a) Design, supply, installation, testing and commissioning of Solar PV Modules capable of generating 150 KWp (AC) electricity at 415 Volt 3 phase system. These Solar PV Modules of 540 watt PERC with a modular efficiency of 17-19.84% as per IEC and MNRE standard or as per approved design parameters with Poly/Multi Crystalline Silicon Solar cells of minimum wattage of 540 watt with minimum 144 cells & efficiency not less than 17 -19.84%, conforming to IEC 61215, IEC 61730, IEC 61701. Solar PV Module should be of approved Indian Brand only and Qualify under the Domestic Content requirement (DCR) norms of NVVN/SECI and testing requirement fixed by MNRE. The PV modules shall be warranted for a period of minimum 25 years, Solar PV modules used in system shall be warranted for their output peak watt capacity, which should not be less than 90% at the end of Ten years and 80% at the end of Twenty Five years. Each Solar PV Module must use RF identification tag. The following information must be mentioned in the RFID used in each module:Name of manufacture of PV module, Name of manufacturer of Solar cell, Month & year of manufacturer (for solar cell and module), Country of origin (lt is mandatory to use cells and modules manufactured in India). I-V curve of the module, Wattage, LM, V-M, & FF for the module, Unique Serial No & Model No of the module, Date & year of IEC PV qualification certificate, Name of the test lab issued IEC certificate. The PV modules used in the solar power projects must qualify to the latest edition of the following International Electro technical Commission (IEC) P module qualification test or equivalent BIS Standards. The PV module must be tested and approved by one of the IEC authorized test centres. 115 (b) Material and labour for Module Mounting structure (MMS) fabricated from hot dip galvansied iron section of suitable size with specified tilt angle according to site requirement & optimum angle to achieve maximum benefit of solar energy and suitable to withstand 180 Kmph wind speed all as per approved design parameters as per MNRE standards and to match with the existing site conditions. Necessary roof treatment to avoid any seepage in future shall be done by the Contractor and the amount included in the rate quoted. The roof tiles shall be dismantled and refixed back in original position. Structure shall be built with brick masonry basement of adequate size as per direction at site including all necessary civil work required for the foundation.(c) Supply, laying & Testing of DC cable minimum size 4/6sq mm multi stranded copper conductor, conforming to relevant IS, weather proof UV resistant with operating temperature up to 120 degrees, minimum rated voltage 1100 volt for inter connection of SPV Modules to array junction box including suitable size of cable lugs, male & female MC4 connectors & joints etc.(d) Supply, installation test and commissioning of protection devices MCCB 400 A, isolator and three phase 4 wire LT energy meter, array junction boxes having rating 150 KWp with over voltage protection and surge protection.(e) Supply, installation, test and commissioning of Grid tie Solar Power conditioning unit / inverter of minimum capacity 150 KWp(DC to AC 415 V in Three phase system) all as per approved design parameters & capable of generating output voltage 415 V AC at rated load condition with efficiency not less than 98 %, conforming to IEC 600682-2 NDE standards with power reduction, LVRT with protections for anti-islanding, Ground fault monitoring, Grid Monitoring, AC & DC Over voltage and under voltage protection, AC & DC short circuit lover current protection and DC reverse polarity protection, graphic display etc. all as specified and as directed.(f) Material and labour for Earthing for Lightning protection for SPV modules etc as per IE rule, MNRE guide line & BIS all as per approved plan complete with galvanised earth plate electrode 600x600x6 mm thick buried directly in ground vertically (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected to and including Gl strip 32x6mm size protected with Gl medium grade pipe 40mm dia for earth electrode up to test point by means of GI nuts, bolts, check nuts and washers including earth work excavation, PCC (1:3:6) type Cl pit and RCC cover ( 1:2:4) type Bl and funnel, with necessary charcoal, salt etc complete. 116 (g) Supply and fixing aluminium strip of size 25 x 3mm thick for roof / down conductor fixed on insulators/ saddles of suitable size for SPV modules lightning protection upto interconnection between Roof top LA to Ground Earthing system. (h) AC Cable: Supply and laying of 150 Sqmm LT XLPE insulated, screened PVC bedded, sheathed with multi-stranded aluminium conductor armoured with galvanised steel wire 1100 volts grade heavy duty conforming to IS 150 Sqmm x 3.5Core as per site requirement.Note (i) :-(a) Before quoting the bid, Contractor or his authorised Engineer/consultant must visit the proposed site to study the site condition.(b) Before commencement of work, contractor shall submit drawings & lay out plan with scale including required qty to Accepting Officer for approval.Note(ii):-(a) The mechanical structures, electrical works and overall workmanship of the Grid solar power plant must be warrented for a minimum of 5 years.(b) All Mechanical, Electrical works shall be carried out as per relevant BIS/lS equivalent standard norms only and also in accordance with the latest edition of the Indian Electricity Act / rules formed thereunder and as amended from time to time.(c) Any other works (mechanical, electrical & Civil) connected to installation, testing & functional requirement of solar photovoltaic power plant of capacity 150 KWp (AC) all as mentioned above and which is not mentioned or included in this Schedule A but required at site necessary shall be carried out by the contractor and quoted rate shall deemed to included for the same(d) Contractor shall provide adequate Spares/items required for minimum period of 1 year maintenance including DC & AC items under scope of work.Note (iii) : Design report shall be submitted before execution of Work at site by the contractor toGE for his scrutiny / comments and futher submitted to AO for obtaining approval. 117 DG SETSupplying, installing, testing and commissioning, factory assembled silentDiesel Engine driven generator set, fully wired alternator AC to give an out put of 400 KVA continuously rating at a power factor 0.8 lagging, 3 phase 4 wire, 415 volts 50 Hzsupply, 1500 RPM, directly coupled with diesel engine liquid cooled mounted on common base frame complete with floor mounting fuel tank (service tank) of adequate capacity with fuel line & accessories, PCC foundation work as per manufacturers instructions, vibration damper pads, control panel & other accessories etc and comprising of following.(a) Diesel Engine: Liquid cooled turbo charged with after cooler to deliver suitable BHP at 1500 RPM under NTP conditions of BS 5514 and conforming to IS 10001/ 10002, DIN 6271 & ISO 3046 with an overload capacity of 10% for one hour in any 12 hours continuous operation with the following accessories: Diesel engine of rated speed at full load electric start developing with system with radiator and including electronic governor control of class A1, engine control panel, lub oil pump, water pump, fuel tank, exhaust pipe with silencer and suitable for electric start with batteries ofadequate capacity and suitable for alternator of specified capacity complete with fly wheel direct/flexible coupling and coupling guard complete.(b) Radiator with blower fan or heat exchanger with guard.(c) Pipe coupling for engine cooling system piping.(d ) Corrosion inhibitor coolant(e) Paper element filters(i) Fuel filter(ii) Lube oil filter(iii) By pass(f) Fly wheel housing and fly wheel to suit alternator.(g) Engine bearing mechanism in fly wheel housing.(h) Shut off coil with safeties for LLOP/HWT/over speed.(i) Dry type air cleaners and vacuum indicators.(j) Residential silencers.(k) Stainless steel exhaust flexible bellows. 118 (l) Battery charging alternator.(m) Exhaust piping made out of STIC C class, MS pipe inclusive of all accessories and hardware, necessary supports scaffolding as per manufacturers recommendations to sustain back pressure with rain cap.(n) Mineral wool insulation 2 inch thick suitable for 400 degree Celsius temperature cladded with aluminium sheet of30 gauge for the entire length of exhaust pipe.(o) First fill of oil, coolant and diesel during commissioning and 12 hours testing.(p) Interconnecting copper cabling of adequate capacity batteries control.(q ) Fuel pipe class STIC 1 /1.5 /2 dia - 01 lot(r) Self starter 24 volts DC.(s) Electric operated electronic governor.(t) Fuel injection pump.(u) Electronic instrument panel, complete with all accessories as per manufacturers specifications displaying the following:-(i) 12vx2 nos -24V Battery. (ii) Water temperature.(iii) lubricating oil pressure.(iv) Engine speed -1500Rpm(v) Engine hours(vi) Frequency.(vii) Voltage.(v) Safety control (Trip and indication).(i) High water temperature(ii) Low lube oil temperature(iii) Overspeed stop 119 (w) Base frame: Sturdy, fabricated welded construction, channel iron base frame (duly painted) for mounting engine and alternator as per manufacturers design alonwith AVM pads.(x) Battery:-24 volts(2x12v Battery) DC, 180AH, maintenance free battery conforming to IS:14257 with leads & terminals (Make- Excide/Amron).(y) Fuel tank:12 hrs. full load diesel storage capacity fuel tank with mounting brackets factory made of 5mm thick HR/MS sheet with level indicator fuel inlet, fuel outlet, air vent, drain plug, inlet arrangement for diesel filling for exterior canopy (without opening its panel) etc complete all as specified and directed.(z) Isolator panel with 630 amp MCCB(aa) Auto logic panel for automatic stat(ab) Alternator: Alternator suitable rated for 400 KVA, 0.8 pf , 415 volts, 3 phase, 4 wire, 50 Hz at 1500 RPM, self excited and self regulated with AVR brushless, screen protected, drip proof, insulation class-H, IP -23, voltage regulationgrade - VG 3 self ventilated and conforming to BS: 5000 / IS: 4722 suitable for engine as mentioned here-in before, conformig to IS: 13364(part-1)Make: KOEL GREEN / stampford/crompten/kirloskar/Greaves(ac) Acoustic Enclosure:- M & L for acoustic enclosure for the above 400 KVA DG set to reduce noise level to 75 dB measured at 1.0 meter distance for audible frequencies as per guide of Central Pollution Control Board andmanufacturers specification and comprising of following from authorised GOEMs of Gen Set manufacturers specified :-(i) Sound insulation : 100mm thick Rock wool (Density 64 Kg/Cum).(ii) Outer body : 1.6mm thick CRCA(iii) Door : 1.6mm thick CRCA(iv) Base frame : ISMC 300(v) Inside illumination : 1 No.- 1 x 18 watt LED fitting of make Phillips/ Bajaj/ Crompton.(ad) AMF Control panel:- Factory fabricated cubicle type, free standing, floor mounted, indoor type, IP-43, AMF control panel, provided with removable rear panels & hinged front panel for easy accessibility, fabricated out of not less than 2.0mm thick CRCA sheet including two coats of powder coated paint over a coat of red oxide primer etc and comprising of following: 120 (ae) AMF control circuit with 4 pole MCCB 630 Amps - 2 nos, with ultimate breaking capacity Icu-50 KA at 415 volts and microprocessor release conforming to IEC 60947 Part-I with breaking capacity Ics=Icu at 415 volts , thermal overload setting 70% to 100%, short circuit setting 5 to 10 times-02 Nos. for main supply & DG set supply with HRC back up fuse complete with all DC control relays/ Line voltage monitor (LVM) as per OEM specifications incorporating motorised stored energy operating Engine start, stop, three attempt starting facility and failure to start etc.(af) Digital load manager : Three phase 4 wire indicating V,I,PF, KVA, KW, F of Enercon make with serial communication port model No. EM6400 with class 1.0 accuracy meter or equivalent make suitable rating of CT per phase- one No.(i) Indication lamp R, Y, B with 3 Nos. of 2A HRC fuses-10 sets.(ii) Bottom gland plate for incoming and outgoing cables.(iii) Circuit diagram plate.Note:- DG set should be as per CPCB- 4 latest norm wef 01 July 2023 of National Clean Air programme (NACP) Act 1981.The contractor shall procure the item within the period given by CPBC in case of revision in CBPC norms. Nothing extra will be paid on account of delay from the part of contractor. DG set shall have an exhaust with stack height of minimum 2m from the top of generator with a cowl. Smoke released from the exhaust of the DG sets indicating that emission parameters are within permissible limits, as prescribed by CPCB, demonstrating compliance with emission limits prescribed by CPCB 2016. 121 Supply, install, test and commissioning of LT Panel, Indoor type, powder coated, 2.00 mm thick CRCA Sheet, CPRI approved having, IP 43, MS angle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with Horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natuaral flow of air. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 1.6 mm thick CRCA Sheat duly compartmentalised for each control gear with louvers and air vent gasket for natuaral flow of air and suiatable provision to accomodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables.Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, track resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. Feeder Panel No.1 (DG Panel ) 122 Incoming:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 630 Amps, breaking capacity 36 KA - 01 No. Ics =100% IcuMetering Unit:- (a) R Y B Indications (LED Type) - 1 sets(b) Digital Multi function meter - 01 No.(c) CTs - 800/5A, CL-1,15 VA - 1 set(d) Horizontal aluminium bus bar for 3 phase 440 V, 50 Hz, 4 wire system of rating 800 Amps for phases and 800 Amps for neutralOutgoing:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 400 Amps, Ics =100% Icu breaking capacity 36 KA- 03 No. (for Package AC Bulk Store, pump house and fire pump & spare)(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 160 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for Pump House & Fire Pump)(c) MCCB, thermal magnetic release, 4 pole, 415 Volts, 80 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for Incianator)(d) MCCB, thermal magnetic release, 4 pole, 415 Volts, 32 Amps, Ics =100% Icu breaking capacity 25 KA- 07 No. (for Terrace pump 1, Terrace pump 2, Power House, High mast 1, High mast 2, Street Light)(e) Digital Ammeter with suitable CT for each outgoing(f) Astro Time switch for 3 phase 20A- 1 No(g) 3 Phase Power contactor 20 amps, with 230 coil 123 SEWAGE DISPOSALM & L for laying of DWCPE sewage pipes line 200 mmdia borepipe sftiffnessclass SN 8 includingsealing of joints fittings etc complete with collers complte all as spcified and directed 124 M & L for laying of DWCPE sewage pipes line 150 mmdia borepipe sftiffnessclass SN 8 includingsealing of joints fittings etc complete with collers complte all as spcified and directed 125 COMPOUND WALLS & F Concertina Coil of 600/700 mm outer dia made out of 2.60 mm dia spring steel wire dipped in corrosion preventive fluid (rusilo 901) of castrol make each coil having min 50 turns (circles) covering 6 m and an average weight not less than 8.57 Kg (plus or minus 5 %) incl handle and spike at both ends of coil erected in position on top of mild steel angle by fixing with 1.70 mm GI wire for securing, coil with fish hook bars, incl necessary welding to MS Sections etc all as specified and directed. 126 GREEN BUILDING NORMS(GRIHA CONCEPT)Supply and Install Organic Waste Converter fully automatic having capacity 50Kg/day, having internal tank made of high quality stainless steel while external panels are powder coated for enhanced product life with necessary electric control panel, cabling necessary civil works for installing machine etc with following requirements:-Type of machine: Fulley automatic in-vessel composterComposting method: 24 Hrs. Micro-organisms-based compostingmachine Type of microganism used: Heat resistant thermophilic bacteria Final Output: Dry organic Soil conditioner/Soil supplementsCycle time: 24Hrs Volume reduction in 24Hrs: 80-85% Internal tank: Stainless steel type Main agitator Shaft: Stainless steel type Input voltage: 415VSpecial features: VFD as standard across all models, Touchscreen standards Daily waste processing: 150Kgs Rated capacity: 7KWPower consumption (KWH par cycle): 13-15Length: 1650, Width: 850,Height: 1455 127 Supply, installation, testing and commissioning Three phase energy meter with the following specifications: Microprocessor based three phase, smart electricity meter, equipped with a bi-directional cellular (NB-IoT) communication that allows it to interact with the head end system (HES) for data collection and configuration with adequate security including electronic static pre paid cum postpaid energy meter rating 415 Volts, 50 Hz of range 10-100 Amps, complying to IS16444:2015 (reaffrimed 2020) and conforming to IS 3779 with LED display and parameters like Voltage, Current, Frequency, Power, Power factor, KWH/KVA, default in built dual source, inbuilt long range (LORAWAN) Communication suitable for outdoor LoRa data accumulator and also compatible for Prepaid and Postpaid online energy monitoring billing system with disconnection /reconnection through remote software / data export to ERP complete with 5 Years warranty.Note:(a) The Energy Meter to be capable of running in both prepaid and postpaid mode.(b) The meters to carry 5 year warranty. (for entire system) 128 Supplying, Fixing, Commissioning and testing of configuration of cloud Hosted multi user web based software with following modules:(i) Head End System (HES): to acquire meter data automatically from DCU sand monitor parameters acquired from meters.(ii) Meter Data Management ModuleThe meter data management module would be responsible for collecting the data from the data concentrator and make the data available to the billing system. The system would support offline meter(a) 30 min instantaneous data from all the meters for seven parameters Cumulative Energy. Cumulative Apparent Energy (as applicable), Power, Current, Voltage, Power Factor and Frequency(b) Monthly billing survey data for cumulative energy and max demand(iii) Billing Module: The billing module would collect the data from the meter data management module, calculate the energy consumption, calculate billing determinant and make energy data/billing data available to admin and end users. The billing module would include functionalities for tariff setup, bill format setup, bill adjustment, occupation billing and vacation billing. It would allow postpaid and prepaid functionality as required.(iv) Occupation and Vacation Module: The system would support occupation/vacation based on the unit catagories. The system would support automatic data capture on occupation and vacation events.(v) Website: There would be a dedicated website forAGE/GE and BSO team to view all the data and information alongwith customer portal for use of customer. The designated users in MES would have the admin access to the application. The MES Staff would also have the access to the key information on mobile App (AndroiandiOS based) for admin use complete all as specified and directed.(vi) Customer Module: The system would include a customer portal for the resident/occupants to login and view their own energy /billing data and recharge facility. There shall be consumer App (Android and iOS based) also to log in and view their own energy/billing data and recharge facility.(vii) Communication Module :The system would provide communication of energy data and bills via print, email and sms methods. 129 (viii) Meter Master Data: The system would support meter data repository. The system would support meter replacement process.(ix) Excel Export: the system would support export of metering and billing data in excel and pdf format.(x) Energy Accounting module: The system would include features of energy accounting, the system would to able to account for total energy block wise, facility wise and would also allow calculations of the unaccounted energy in case total energy meter is also available.(xi) Prepayment/Recharging Facility:The system should periodically monitor the energy consumption of prepaid consumers and decrease the available credit based on the consumption. The system should allow online/digital recharging through consumer App (Androidand iOSbased) and Web portal. The configuration and necessary arrangement for payment gateway and E-MRO facility shall be deemed to be included in the quoted rate. The system should sendconnect/disconnect command on the basis of available credit.Low credit alarm: The system will give an alarm over the consumer App and SMS to the registered mobile number in case the credit in the meter goes down be low apredefined limit.Emergency credit: The meter will work even when the credit falls down to zero to prevent disconnection. This limit shall be configurable. The system should support happy hours inorder to prevent disconnection in non working hours and on holidays. The Happy hours should be configurable complete all as specified and directed. 130 Supply, Installation, Testing and Commissioning of DCUs/Gateways and the arrangement of Sim cards or Internet to enable reliable medium for two-way communication between Smart Meter & HES. The data acquisition (Push/Pull) frequency shall be, configurable. It shall push events such as tamper, power off etc. to HES immediately on occurrence/receipt from meters. It shall have provision for the cellular, WiFi and Ethernet communication for the backhaul to HES. It shall be capable to handle data of minimum 1000 Nos. of any type of smart meter (1ph/3ph).It shall be able to communicate with the nearest meters at a distance of at least 500 m, depending on topographical features. Communication of the nearest meters with other meters shall be established through appropriate mesh formation. RF Mesh shall support self-forming and self-healing features. The equipment shall be weather proof and dust proof (minimum rating: IP54 for indoor and IP65 for outdoor installation). It shall have rechargeable battery with backup for 1(one) hour for normal meter reading, to push tamper event, carry out on demand reading, etc complete all as specified and directed. 131 Hosting GPRS (4G) charges for Gateway for five years from the date of completion F Including 2 years waranty and 2 years Maintinance after warranty) Make:-Airtel/Jio/Vodafone 132 Supply and installation of digital Water flow meter 50mm suitable for domestic and commercial applications complete all as specified and directed. 133 Supply and installation of digital Water flow meter 40mm suitable for domestic and commercial applications complete all as specified and directed. 134 ARBORICULTUREM & L for excavation of pits size 30cm x 30cm x 30cm in loose soil and filling the pit with mixture of river sand and approved top soil in the proportion of 1:3 mixed with 30% of cow dung powder, 100gms of bone meal and 100gm of neem cake powder 135 All as per item No 13.121 above but pit size 60cm x 60cm x 60cm 136 Supplying and planting red palm or royal palm healthy sapling having 45cm height and shall have a minimum height of 65cm after 6 months 137 Supplying and planting coconut tree healthy sapling having 75cm height and shall have a minimum 95cm after 6 months. 138 Supplying and planting flower plants(Champa/ hybrid hibiscus/ Hybrid west Indian Jasmine/ Hybrid Plumeria white plant/ Panama yellow plant/ Oleander) healthy sapling having 10cm minimum height and shall have a minimum 25cm to 30cm height after 6 months. 139 Supplying and planting phylanthus healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 140 Supplying and planting bougainvillea colour flower plants healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 141 Supplying and planting song of India flower plants healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 142 Supplying and planting dracaena flower plants healthy sapling having 15cm to 30 cm height and shall have a minimum 60cm height after 6 months. 143 Supply and planting mexican grass including providing manure as directed. 144 PILE FOUNDATIONBoring 450 mm dia piles to any depthin any type of soil/ strata by anyapproved method, complete all as shown on drawings and as specified anddirected.Note:- The quoted rate shall include for mobilization and demobilisation of piling equipment, making approaches to site or point of pile boring if necessary. Nothing extra shall be paid on this account. 145 Boring for bored cast in situ pile 600 mm dia to any depth through any type of soil / strata, using DMC method (Direct Mud Circulation)and getting out & disposal of spoil to any distance outside of MD land , complete all as specified and as directedby the EngineerIn Charge 146 M & L Reinforced cement concrete of grade M-35 design mix (RMC) as per IS-456using 20 mm graded stone aggregate in cast in situ DMC bored pile of any length / any sectionscomplete all as specified and as shown on drg 147 M & L Reinforced cement concrete of grade M-35 design mix (RMC) as per IS-456using 20 mm graded stone aggregate in pile caps / grade beams complete all as specified and as shown on drg 148 Providing TMT bars (CRS/HCRM/CRM) in reinforcement 10 mm dia and over for bored cast in situ piles of any length and any dia all as shown on drgs including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with and including 0.9mm dia MS wire (annealed) or welding so as to secure the bar firmly in position/ required shape complete all as specified and shown on drgs (Fe-500D). 149 Providing TMT bars (CRS/HCRM/CRM) in reinforcement 10 mm dia and over for pile caps and grade beams, cut to length, bent to shape required, hooking ends and binding with and including 0.9mm dia MS wire (annealed) or welding so as to secure the bar firmly in position/ required shape complete all as specified and shown on drgs (Fe-500D). 150 All as per item No 13.136 here-in-before but5mm dia and over upto and including 10mm dia as in helicals for piles and stirrups for grade beams complete all as specified and directed. 151 M & L for providing PCC (1:4:8) type D-2 using 40 mm graded stone aggregate for concrete layer below pile caps foundation complete all as specified and directed. 152 Formwork to sides of pile caps/ grade beams and similar work, rough finished surface of concrete flat all as specified and as directed. 153 M & L for carrying out non destructive integrity test all as per IS 2911 (Part 4) 2013 for 600 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed all as specified and directed. 154 M & L for carrying out non destructive integrity test all as per IS 2911 (Part 4) 2013 for 450 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed all as specified and directed. 155 M & L for carrying out Initial Load test (vertical load test) cast in situ piles of 600 mm dia as per IS 2911 (Part 4) 2013 including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note :- Providing and installing test piles shall measured and paid separately) 156 M & L for carrying out Initial (lateral load test) cast in situ piles of 600 mm dia as per IS 2911 (Part 4) 2013including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note :- Providing and installing test piles shall measured and paid separately) 157 M & L for carrying out Initial load test (pull outtest as per design load) of cast in situ piles of 600 mm dia as per IS 2911 (Part 4) 2013including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note :- Providing and installing test piles shall measured and paid separately) 158 M & L for carrying out Routine load Test (Vertical load)all as per IS 2911 (Part 4) 2013 for 600 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed 159 Testing of piles Initial load test (verticle load test) for 450mm dia cast in situ bored piles all as per IS including removing the testing equipments from the site after testing is completed all asspecified and as directed 160 M & L for carrying out Initial Load test (lateral load test) cast in situ piles of 450 mm dia as per IS 2911 (Part 4) 2013 including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note:- Providing and installing test piles shall measured and paid separately) 161 M & L for carrying out Initial load test (pull outtest as per design load)of cast in situ piles of 450 mm dia as per IS 2911 (Part 4) 2013including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note :- Providing and installing test piles shall measured and paid separately) 162 M & L for carrying out Routine load Test (Vertical load)all as per IS 2911 (Part 4) 2013 for 450 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed
Contract Date : 11 Feb, 2026   |   Contract Value : 59.27 Crore
Disclaimer

We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.

Tender Detail
Website https://www.ireps.gov.in
Quantity
MSME Exemption No
Tender Type Open Tender
Startup Exemption Click Here
Competitive Bidding NCB
Similar Tenders
TENDER INSIGHTS

858

Electric Tenders
Live
CLICK TO KNOW MAXIMUM WIN

Tell us about your Product / Services,

We will Find Tenders for you

🇮🇳 +91
TenderDetail
Loading tenders