Tender Summary / Eligibility Criteria
Providing And Fixing Safety M.S. Hard Drawn Jali With M.S. Angle Frame For Three Generator Sets
Documents
Download All
| Sl. No. | Item Description |
|---|---|
| 1 | <table border=\"1\" class=\"dataframe\"><thead><tr><b>Name of Work :Providing and fixing safety M.S. hard drawn jali with M.S. angle frame for three generator sets near Block No.-17 (behind) at IGNOU Campus, Maidan Garhi, New Delhi-110068.</b></tr><tr><td>Sl. No.</td> <td>Item Description</td> </tr> </thead> <tbody> <tr><tr><td>1</td><td>Structural steel work riveted, bolted or welded in built up sections, trussesand framed work, including cutting, hoisting, fixing in position andapplying a priming coat of approved steel primer all complete.</td></tr><tr><td>2</td><td>Providing and fixing hard drawn stell wire fabric 75x25 mm mesh of weight not less than 7.75 kg per sqm to window frames etc. including M.S. flat 30x05 mm beading and priming coat with approved steel primer all complete.</td></tr><tr><td>3</td><td>Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: One or more coats on old work.</td></tr><tr><td>4</td><td>Providing and fixing bright finished brass Dash fastners 12.5 mm dia and 75 mm long to hold and fixed M.S. plate on floors as per site requirement and direction of Engineer-in-charge.</td></tr></tr></tbody></table> |
No Corrigendum
Probable Bidders
AI engine predicts probable bidders to help you bid strategically.
MSME Exception
Technical
Tender involves procurement of high capacity electrical equipment including diaphragm coupling of pump &
motor with 90kW capacity at 2900 RPM. The project scope includes installation, testing, commissioning and
operational handover.
Previous / Similar Result
BRR : 9059068
Providing And Fixing Safety M.S. Hard Drawn Jali With M.S. Angle Frame For Three Generator Sets
BRR : 9329093
Tender For Electrical Works For The Government Exhibition 2025 At Salem; 1 Hire charges for erecting tubular iron pole with 3 phase cross arm suitable for 5 wire line with insulators and C.I. Knob and earthing of each pole individually as per I.S.I. standards. (Tubular poles will be supplied at free of cost Departmentally atSalem) If any damage occurs to the poles the cost will be recovered from the contractor.Before erection, the poles should be neatly painted with silver colour.As described an item 1 a but including the hire charges for poles which will have to be provided by the contractor at his cost. 2 Hire charges for erection of stay set complete with necessary gut shackle. 3 Hire charges for fixing extra 3 phase 4 wire / 5 wire cross arm with insulators and C.I. Knob. 4 Hire charges for run of 4/5 of No.4 HDB / 6 HDBACSR for OHLT Mains for pole to pole. 5 Hire charges for erection of 6M long GI pipe 3 dia for street lights or aerial stays with earthing as per I.S.I standard. 6 Hire charges for supply and laying / running of 3.5 core LTUG cable of all sizes varying between 25 sq.mm. to 90 sq.mm/150 sq.mm. to 240 sq.mm/300 sq.mm including earth connection in ground / on post / on wall wherever necessary. 7 Hire charges for supply and laying / running of 2 core LTUG cable of all sizes varying between 2.5 sq.mm to 25 sq.mm including earth connection in ground / on post / on wall wherever necessary for single phase supply. 8 Hire charges for run of 2/ 4 of 6 sq.mm to 10 sq.mm/16 sq.mm PVC sheathed copper conductor in suitable PVC pipe with continuous earth connection to be laid in ground / to be run on post. 9 Hire charges for supply & erection of main panel board (Bus bar) of 400 Amps capacity including main switches for incoming supply and outgoing feeders with HRC fuses, complete with 2 Nos. of earthings as per I.S.I standard with indicator lamps, Danger Board, earth buses, inter connections and earth connections. 10 Hire charges for supply & erection of sub panel board (sub main bar) for distribution of main with busbars, suitable for 100 Amps or 60 Amps or 30 Amps or 15 Amps main switches, with provision for fuse carriers for individual lines, indicator lamps, earth connections with 2 numbers of earthing, inter connections etc., complete. 11 Hire charges for supply and fixing of single phase main switch of ratings between 15 Amps to 32 Amps in suitable wooden plank / M.S. box with clamps etc. to be fixed on pole / wall wherever necessary with earth connection and with all accessories complete. 12 Hire charges for supply and fixing of 3 phase main switch of ratings varying between 15 Amps to 32 Amps / 60Amps to100 Amps in suitable wooden plank / M.S. Box to be fixed on pole / wall wherever necessary with earth connection and with all accessories complete. 13 Hire charges for supply and fixing of 100A To 200A change over switch on suitable wooden plank / M.S. box with earth connection and with all accessories complete. 14 Hire charges for run of overhead service connection lines by 2/4 of 6 sq.mm. to 10 sq.mm./16sq.mm to 25 sq.mm PVC sheathed S.C copper cable on reel insulators with bearer with for single phase, 3 phase supply. 15 Hire charges for 3 pin 5 Amps/15 Amps wall plug on Modular board with wiring and earth connection. 16 Hire charges for supply and fixing of 4 x 20 watts twin LED street light fittingtubes of any colour as directed by the Departmental Officers including control switch wiring etc. complete. 17 Hire charges for supply and fixing single 4 x 20w patti fitting with LED tube of any colour as directed by the Departmental Officers including control switch wiring etc. complete. 18 Hire charges for supply and fixing bulbs of 100w capacity and of any colour as directed by the Departmental Officers with holder, colour switch, wiring etc. complete. 19 Hire charges for supply and fixing of serial sets (of 24 volts 11 Nos. per set or 12v. 22 Nos. per set or 6V 44 Nos. per set) wrapped with various colour papers, necessary connections, wiring etc., complete. 20 Hire charges for electronic chaser moving and ornamental works for the serial sets with all accessories. 21 Hire charges for supply and fixing aerial fuse unit on suitable wooden board for single phase service (from 15 Amps to 32 Amps) on the poles. 22 Hire charges for supply and fixing aerial fuse unit on suitable wooden board for 3 phase service (from 15 Amps to 32 Amps/60 Amps to 100Amps) on the poles or walls wherever necessary. 23 Hire charges for the provision of earth pits and earthing arrangements as per I.S.I standard with GI wire, bolts and nuts, charcoal, common salt etc. 24 Hire charges for supply and fixing the name board “muR¥ bghU£fh£Á” on plywood cut-out of size 10m x 09m neatly painted with each letter of size about 0.6m arranged with serial colour bulbs automatic running system wiring etc., complete (The contractor has to make his own arrangements for providing supporting structure etc.) 25 Hire charges for supply and fixing pedestal fan (Five Star) or table fan or ceiling fan (Crompton Make) with all accessories complete. 26 Hire charges for supply and fixing of split neutral guarding porcelain insulator with No.8 SWG GI wire at equal intervals of 2 meters. 27 Hire charges for supply and fixing cut off type street light lantern suitable for 200w LED lamp (Philips/Hevells Make)fitting necessary support, connections, etc. complete. 28 Hire charges for supply and fixing Digital single/ Three phase watt hour meter with necessary connections etc. complete on suitable wooden plank & supports. 29 Hire charges for single 18w/20w LED BATTEN LIGHTS (Philips Make) colour as directed by Departmental Officers with wiring etc. complete. 30 Labour charges for the transportation of street light tubular poles of 33 feet length from salem godown to Salem ground Including loading, unloading and safely handing over it to the exhibition officers at Salem after dismantling.Damages, if any, during transit will be recovered from the contractor. 31 Labour charges for the transportation of street light tubular poles of 33 feet length from Salemground to salem godown Including loading, unloading and safely handing over it to the exhibition officers at salem after dismantling.Damages, if any, during transit will be recovered from the contractor. 32 Hire charges for providing & fixing of three phase miniature circuit breaker (10 Amps to 40 Amps) Legrand Make on a suitable board, wall or pole wherever necessary for three phase connection including inter connection, with all accessories, complete. 33 Hire charges for providing & fixing of three phase earth leakage circuit breaker (10 Amps to 40 Amps) ( Legrand Make) on a suitable Teak Wood board, wall or pole wherever necessary for three phase connection including inter connection, with all accessories, complete. 34 Hire charges for supply and fixing of cut-off type street light lantern type suitable for 100 watts LED light fitting with bulb, condenser and all accessories complete with provision for support and wiring etc. 35 Hire charges for providing & fixing of single phase miniature circuit breaker (10 Amps to 20 Amps) ( Legrand Make) on a suitable Teak Wood Board, wall or pole where ever necessary for three phase connection including inter connection, with all accessories, complete. 36 Hire charges for supply & fixing of 400 watts Metal Halide day light fitting with bulb, condenser and all accessories, complete with necessary support, wiring connections etc., complete. 37 Hire charges for supply & fixing of 30 watts LEDwith holder, control switch, wiring etc., complete, as directed by the Departmental Officers. 38 Hire charges for providing public address system complete 1. microphones, (Ahuja Make) - 4 Nos,2. colour flood lights, (phlips make)- 4 Nos,3. speakers (Ahuja Make) - 4 Nos, and necessary Laptop (Dell Make) - 2 Nos,CD players, CD and Amplifier system (Ahuja Make) to both pen drive and CD compatibility with a competent operator and 2 Nos. Helpers to conduct day to day entertainment programme on the stage of Auditorium along with one approved Backdrop screen, 2 Nos. of Drama Screens depicting scenaries and necessary accessories for the entire exhibition period including maintenance of their system as directed by the Departmental Officers, CCTV Camera System ( 5 cameras in important places) with monitor facility at exhibition office. 39 Hire charges for providing 5 kg Dry type (Co2) Fire Extinguishers Fire Marked Buckets with clean and dry sand with accessories wherever necessary and maintaining the same complete for the entire exhibition period as instructed by the Departmental Officers. 40 Hire charges for supplying operating and maintaining 3.Nos, of diesel generators set of capacity 125 KVA or equivalent Comprising Engine, Alternator, Control Panel, Fuel Tank, Base Frame, Electric Starting Equipment and engine instrument panel complete in an acoustic enclosure to generate uninterrupted power supply to a connected load of 300 KW (Approximately). The fourth diesel generator set of 125. KVA capacity or equivalentshould be kept as standby with change over switch and inter connection arrangement at site for the entire duration of fair period of 50 days (Approximately) and to attend major break down and failure by deploying one competent person as generator operator and also to provide suitable angle iron frame foundation as required for erection of generator set, control panel, battery, fuel tank, etc. providing suitable size of UG cable from alternator to control panel, suitable earth pit arrangement, exhaust pipe arrangement with lagging and with first charging of lubricants, battery, fuel and oil, filters etc. tested with full load operation complete as directed by the Departmental Officers. 41 Towards cost of power consumption from diesel generator sets per unit. (KWHR) including cost of fuel, lubricants, oil, replacement of spares and service, complete. 42 Transportation charges for the generators as described in item No.1 from the company to Salem and back after closure of Exhibition. 43 Hire charges for erection and commissioning of 1 No. 250 Amps terminal interlinking arrangement made with suitable 250 Amps change over switching system between 1 No. 10 KVA and 1 No. 30 KVA Diesel Generator service connection and generator feeder points 2 Nos. with suitable angle iron frame work, earthing etc. complete as directed by the Departmental Officers on hire basis for entire duration of Exhibition period. 44 Hire charges for providing 3.5 x 120 sqmm LT UG Aluminium armoured cable in earth / pole / wall as required including earth connections for the entire duration of exhibition period. 45 Hire charges for providing 4 pole 200 Amps busbar chamber with 2 Nos. 250 A main switch with two locks one key arrangement (or) 250 Amps on load 4 pole change over switch with suitable enclosures fixed on angle iron frame work with earthing complete etc. for the entire duration of exhibition period. 46 Providing suitable CT energy meter for all the generators and to obtain safety certificate from Electrical Inspectorate for the operation of generator sets. 47 Hire charges for providing adequate capacity of emergency lights at locations instructed by Departmental Officers for entire duration of Exhibition. 48 Hire charges for providing, operating, maintenance of 1 No. 10 KVA Diesel Generator set complete with necessary change over switch along with a competent Generator Operator inclusive of cost of lubricants, fuel, oil, battery, etc., for the 8 Hours per day(from 8am to 4pm) ofentire exhibition period as directed by the Departmental Officers.(Including Transportation Charge) 49 Hire charges for providing canbon-di oxide (CO₂) Type (or) Dry Chemical powder type fire extinguishers and Fire buckets with clean, dry sand and accessories wherever necessary for emergency use, for the entire period of the exhibition. 50 Hire charges for providing, operating, maintenance of 1 No. 30 KVA Diesel Generator set complete with necessary change over switch along with a competent Generator Operator inclusive of cost of lubricants, fuel, oil, battery, etc., for the 8 Hours per day(from 10pm to 6am) of entire exhibition period as directed by the Departmental Officers.(Including Transportation Charge)
BRR : 8571785
Tender For Renewal Of 250 Kva Generator Set With Amf Control Panel At Collectorate Building In Tiruvallur District.; 1 Renewal by supply, erection, commissioning, testing and handing over of 1No 250KVA Diesel Generator Set (CPCB IV+Norms) canopy, fuel tank battery charging alternator with AMF Control Paneldeveloping 3phase electrical output 250KVA powered by diesel engine of 0.8P.F Three phase 415/420Volts, 50c/s, 310 BHP at 1500RPMas detailed below. a]. ENGINE: KIRLOSKAR oil engine make model 6SL 8800 TA turbo charged vertical inline 6 cylinders. Liquid cooled diesel engine developing 310HP at 1500 RPM conforming B.S 5514 / 6490 or IS 10000 incorporating the following accessories. a]. The engine shall comprise the following standard fittings Flexible coupling with guard, Flywheel, Air cleaner, Fan blower type with guard, Radiator with guard, water pump engine mounted, Fuel pump, Fuel filter, Lubrication oil filter, Lubrication oil pump, Governor (mechanical/hydraulic) Exhaust silencer residential type. b]. Electric starting equipment, complete with starter motor, dynamo and battery with cables, flexible exhaust piping of 50cms length. 2 c].ENGINE INSTRUMENT PANEL MOUNTED: Starting push button with key, lubricating oil temperature gauge, lubricating oil pressure gauge, water temperature gauge, safety control for low lubricating oil pressure, safety control for high water temperature, safety control for over speed, hour meter and RPM meter indicator, battery charging ammeter. The engine should be capable of providing 10% overload for one hour for every 11 hours continuous running at full load.d]. ALTERNATOR: KIRLOSKAR GREEN make Alternator rated at 250KVA, 415V, 0.8PF, 50Hz, 3phase , 4wire self regulated and self exited with voltage regulation of + or 1% class “H” insulation in SPDP enclosure and confirming to IS 4722/BS 2613, suitable for close coupling. trip proof with IP21 protection as per ISI.e]. AMF CONTROL PANELS The control panel (cubical) should be vermin and dust proof and fabricated with 16 SWG CRCA sheet metal and floor mounted with suitable hinged doors, enamel painted & incorporating the following. 3 1No.KWH meter.1No. Frequency meter1No. Voltmeter selector switch.1No. KW meter1No.Ammeter selector switch with Ammeter.1No.AC voltmeter.3NOs.Current transformer with suitable ratio.1Set of pilot lamps and push button switch for ON and OFF operation.1Set input terminal board.1Set output terminal board. 1No. MCCB of suitable capacity with magnetic thermal overload release instantaneous short circuit trip under voltage release.1Set of HRC fuses for back up protection.1Set of fuses for the meters1No.power factor meter 4 1No. Battery charger for charging the battery from mains comprising of i)Transformer ii)Rectifier iii) DC ammeter iv)DC voltmeter v)charging rate selector switch vi)circuit breaker vii)voltage regulator [Note: this will be in addition to the battery charging alternator fitted on the engine] 1Set of Audio and visual indications arrangement for:i)Low lubrication oil pressureii)Over speediii)High water temperature1no Isolator to isolate the neutral 1no “set on” indicating lamp and1no “load on” indicating lamp 1no Earth fault relayNote: the engine shall trip for the following conditions1) Low lubrication oil pressure2) Over speed 3)High water temperature 5 The panel should be complete with bus bars internal connections and with necessary fuses, cables and other accessories and with tapping for the incoming supply from the alternator and for the outgoing supply to the loadf].FUEL TANK: Fuel tank of 460 liters capacity to generator with inlet and outlet connection filling cap drain plug level indicator etc., complete.g].BASE FRAME: The base frame should be fabricated with MS channel of rigidly welded constructed for mounting the generator set. The engine and alternator should be coupled by suitably designed diaphragm type flexible coupling with guard and mounted on the base frame with proper alignment. The supply of generator set includes loading, unloading and transportation charges. 6 h]. Supply of maintenance and operating manual with list of engine parts and alternator parts.j]. Erection Testing and CommissioningBATTERY:25 plate 150 AH 12V battery with one set of connecting leads of 75 Sq.mm copper cable with sockets etc.,MANUALS & DOCUMENTATION : Operation and maintenance manual for engine, maintenance manual for alternator, engine test certificate, alternator test certificate, circuit diagram for control panel, DG set test certificate, CPCB compliance label fixed on canopy. Supply of ACOUSTIC ENCLOSURE suitable for 250KVA Diesel Generator set. The acoustic enclosure should be free standing floor mounting type with modular construction with the provision to assemble and dismantle easily and designed to suit all weather conditionsThe construction details / specification:Acoustic Modules: Outer body: 2mm thick CRCA sheet Door: 2mm thick CRCA sheet 7 Inner surface:0.8mm thick GI perforated sheet / Perforation area should be > 2 / 3 of total area Insulation:100mm thick Rock Wool (Density: 65kg / cub.m or as approved by competent authority) to suit CPCB normsSkeleton structure Channels: should not be less than ISMC75 and ISMC 100.Cleats: should not be less angle 40x6mm and 50x 6mm.The sheet metal competent shall be pre-treated by seven tank process. The joints should be designed in such a way the airborne noises are prevented. For larger panels, special care should be taken to prevent deformation. Adequate ventilators should be provided so that the generator performance is not affected and also the temperature inside is limited.The maximum permissible sound pressure level should be as per the norms prescribed by the central Pollution Control Board/ State Pollution Control Board / Competent Authority concerned or should be 75db(A) at 1meter from the enclosure surface, whichever is advantageous to the department. 8 The emergency stop and suitable meter with digital display to indicate inside ambient temperature of the enclosure should be available on the enclosure panel.The enclosure should be only poly polished based coated inside and outsideThe enclosure provided shall be duly approved by the Engine Manufacture of the Engine provide for Diesel Generator sets mounted inside and should be to the satisfactionof Inspection / Testing Authority concerned(Kirloskar/Cummins Make) 9 Erection of Gen set:- Providing suitable concrete foundation with cement concrete 1:2:4 with sand cushion all around the foundation erection of 250KVA Generator set over the existing foundation and erection of Generator set with proper alignment over the existing foundation to suit 250KVA Gen set. 10 Renewal supply and installation of exhaust piping with Silencer of sufficient length with suitable MS pipe so as to extend outside the generator with necessary thermal insulation 11 Renewal by supply and Demonstration of the following Safety Accessories.a) 1 Meter X 1 Meter X 1/2 Inch Rubber Mat - 2 Nosb) One Set of 4 Nos. 9 Liters fire Buckets with Metal Stand Frame - 1 Setc) First Aid Box with Medicine - 1 Nod) 11KV Rubber Hand Gloves - 2 Nose) 2 Kg Capacity Dry Powder Type Fire Extinguishers - 2 Nosf) Hand operated pump to transfer fuel from standard barrel to fuel tank - 1 No.g) First aid chat in Tamil and English - 1No.h) Battery water acidity tester - 1 No 12 Renewal by Supply and clamping of 3 ½x 185 sqmm PVC LTUG armoured LTUG cable on post or on wall with MS clamps. (400A Panel) 13 Renewal by supply and fixing of brass cable gland for 3-1/2 x 185 sq.mm. PVC armoured LTUG cable with earth connection (400A Panel) 14 Renewal by supply and providing cable end termination of 3-1/2x185sq.mm.PVC LTUG aluminium armoured cable with necessaryaluminium cable sockets by crimping etc with electrical connection complete (400A Panel) 15 Renewal by Supply and clamping of 3 ½x 120 sqmm PVC LTUG armoured LTUG cable on post or on wall with MS clamps. (250A Panel) 16 Renewal by supply and fixing of brass cable gland for 3-1/2 x 120 sq.mm. PVC armoured LTUG cable with earth connection(250A Panel) 17 Renewal by supply and providing cable end termination of 3-1/2x120 sq.mm.PVC LTUG aluminium armoured cable with necessaryaluminium cable sockets by crimping etc with electrical connection complete(250A Panel) 18 Renewal by supply and fixing of 400 A Three phase 500V 4 Pole Change over Switch on suitable angle iron frame work with MS cable entry boxes with Earth connection only 19 Earthing as per PWD standard with an earth electrode of 2 metre Class B GI pipe of dia not less than 32mm complete with necessary masonry work. 20 Renewal by supply and run of 25mm x 3mm tinned copper flat with necessary clamps/supports on wall/floor/ground for earth connection 21 Preparation of site plan, physical layout, electrical line schematic diagram in 10 sets getting drawing approval from CEIG preparation of completion report, rectification report and arranging CEIG inspection and obtaining safety certificate preparation of 1 set of approved drawing and a copy of safety certificate in a neat frame work to be fixed in generator room and payment of CEIG inspection fees. 22 Renewal by Supply, Erection, testing and commissioning of 400A capacity dust and vermin proof cubical Vertical type panel board made up of 16SWG CRCA sheet with supply and fixing of the following interior mountingswitches with HRC fuse link arranged Horizontally with horizontal bus bar chamber and left and top side cable chamber. 1) 400A FP MCCB (I/C)-1No 2) 250A TPN MCCB (O/G) -4Nos and3)125A TPN MCCB (O/G)-2 NosThe copper buses shall be mounted on SMC bus bar insulator at proper and sufficient interval as per IE rules. The bus bar chamber shall be segregated from the adjacent chamber by providing hylum sheet of 3mm thick as partition.Heat shrinkable sleeves shall be provided for bus bar with colour code.The panel shall be provided with metering chamber consisting of 0-500V Voltmeter with selector switch, 0-400A Ammeter with selector switch and CT coil. LED indication lamp shall be provided with to toggle switches and backlit fuse units. The panel shall have powder coated painting of approved colours, approved by the department officers. The DANGER board / caution board shall be fixed in front side of panel boardThe panel shall be mounted on 3” x 1 ½” x ¼” MS base channel provided all round at the bottom of the panel. The whole arrangements shall be erected on a masonry pedestal to be constructed with suitable foundation with bolt and nuts, such thatthe lowest SDFunit fuse handle is at aheight of 0.75m from the ground level 23 Renewal by Supply, Erection, testing and commissioning of 250A capacity dust and vermin proof cubical Vertical type panel board made up of 16SWG CRCA sheet with supply and fixing of the following interior mountingswitches with HRC fuse link arranged Horizontally with horizontal bus bar chamber and left and top side cable chamber. 1) 250A FP MCCB (I/C)-1No 2) 125A TPN MCCB (O/G) -2Nos and 3) 63A TPN MCCB - 6 Nos(O/G) The copper buses shall be mounted on SMC bus bar insulator at proper and sufficient interval as per IE rules. The bus bar chamber shall be segregated from the adjacent chamber by providing hylum sheet of 3mm thick as partition.Heat shrinkable sleeves shall be provided for bus bar with colour code.The panel shall be provided with metering chamber consisting of 0-500V Voltmeter with selector switch, 0-400A Ammeter with selector switch and CT coil. LED indication lamp shall be provided with to toggle switches and backlit fuse units. The panel shall have powder coated painting of approved colours, approved by the department officers. The DANGER board / caution board shall be fixed in front side of panel boardThe panel shall be mounted on 3” x 1 ½” x ¼” MS base channel provided all round at the bottom of the panel. The whole arrangements shall be erected on a masonry pedestal to be constructed with suitable foundation with bolt and nuts, such thatthe lowest SDFunit fuse handle is at aheight of 0.75m from the ground level 24 GST @ 18% 25 Providing fuel oil to run the set for 8 hours on load testing and commissioning using water rheostat or suitable leading element.First charging of fuel oil to full capacity and first charging of battery while handing over to dept.
BRR : 9474718
Tender For Electrification And Plumbing And Sanetry Works - Wiring point for light width 1.5 sq. mm FR PVC insulated multistrand single core Copper Conductor cable in PVC conduit with 15 sq.mm. FRLSH PVC insulated ltistrand copper conductor cable as earthing wire drawn inside the conduit partly concealed in wall & partly laid in slab along with the reinforcement before concreting.complete with modular type switch & ceiling rose / angle / batten holder on 3 mm thick phenolic laminated backelite sheet etc complete in all respects as Brected, including matching color wash 3 Wiring point for light width 1.5 sq. mm FR PVC insulated multistrand single core Copper Conductor cable in PVC conduit with 15 sq.mm. FRLSH PVC insulated ltistrand copper conductor cable as earthing wire drawn inside the conduit partly concealed in wall & partly laid in slab along with the reinforcement before concreting.complete with modular type switch & ceiling rose / angle / batten holder on 3 mm thick phenolic laminated backelite sheet etc complete in all respects as Brected, including matching color wash 4 Wiring point for light width 1.5 sq. mm FR PVC insulated multistrand single core Copper Conductor cable in PVC conduit with 15 sq.mm. FRLSH PVC insulated ltistrand copper conductor cable as earthing wire drawn inside the conduit partly concealed in wall & partly laid in slab along with the reinforcement before concreting.complete with modular type switch & ceiling rose / angle / batten holder on 3 mm thick phenolic laminated backelite sheet etc complete in all respects as Brected, including matching color wash 5 Wiring point for light width 1.5 sq. mm FR PVC insulated multistrand single core Copper Conductor cable in PVC conduit with 15 sq.mm. FRLSH PVC insulated ltistrand copper conductor cable as earthing wire drawn inside the conduit partly concealed in wall & partly laid in slab along with the reinforcement before concreting.complete with modular type switch & ceiling rose / angle / batten holder on 3 mm thick phenolic laminated backelite sheet etc complete in all respects as Brected, including matching color wash 6 Wiring point for light width 1.5 sq. mm FR PVC insulated multistrand single core Copper Conductor cable in PVC conduit with 15 sq.mm. FRLSH PVC insulated ltistrand copper conductor cable as earthing wire drawn inside the conduit partly concealed in wall & partly laid in slab along with the reinforcement before concreting.complete with modular type switch & ceiling rose / angle / batten holder on 3 mm thick phenolic laminated backelite sheet etc complete in all respects as Brected, including matching color wash 7 Wiring point for light width 1.5 sq. mm FR PVC insulated multistrand single core Copper Conductor cable in PVC conduit with 15 sq.mm. FRLSH PVC insulated ltistrand copper conductor cable as earthing wire drawn inside the conduit partly concealed in wall & partly laid in slab along with the reinforcement before concreting.complete with modular type switch & ceiling rose / angle / batten holder on 3 mm thick phenolic laminated backelite sheet etc complete in all respects as Brected, including matching color wash 8 Wiring point for light width 1.5 sq. mm FR PVC insulated multistrand single core Copper Conductor cable in PVC conduit with 15 sq.mm. FRLSH PVC insulated ltistrand copper conductor cable as earthing wire drawn inside the conduit partly concealed in wall & partly laid in slab along with the reinforcement before concreting.complete with modular type switch & ceiling rose / angle / batten holder on 3 mm thick phenolic laminated backelite sheet etc complete in all respects as Brected, including matching color wash 9 Supply and fixing of submains with two number 4 sq.mm FRLSH PVC insulated 1100 V grade single core multistrand opper conductor cable in 20mm dia heavy 20 mm thick] PVC conduit with l Number 2.5 sq.mm. FRLSH PVC insulated 1000 grade multistrand copper conducted cable as earth continuity wire drawn inside the conduit complete in all respect. 10 Supply and fixing of submain 2 number f FRLSH PVC Insulated 1100 V grade tranded single core copper conductor cable in 20mm dia heavy duty (2mm thick) PC conduit partly concealed in wall and party land in slab along with reinforcement belar concreting with one number 4.0 Somm FRLSH PVC Multistand copper earth munity wire including colour wash etc. omplete in all respects. 11 Supply and wiring of submain with 4 number 6 sqmm FRLSH PVC insulated 1100 V grade multistranded single core apper conductor cable in 32 mm dia heavy 2mm thick PVC conduit partly oncealed in wall and partly laid in slah aung with reinforcement befor concreting wtwo number 4 sq. mm FRLSH PVC muated multistrand copper earth manity wire drawn inside the conduit piete in all respect. 12 Supply and wiring of subamin with 4 number 10 sqmm FRLSH PVC insulated grade multistranded single core per conductor cable in 32 mm dia heavy 2m thick PVC conduit partly ein wall and partly laid in slab gwreinforcement befor concreting bes number 6 sqmm FRISH PVC Mates copper conductor cable as earth munity wire including colour washer mga respects 13 Supply and fixing of single wall bracket onMUFEG board base etc required. 14 Supply and fixing of recess/surface/pendent mounting round 10 to 15 watt LED Down Lighter having powder coated die cast aluminium housing with heat sink, diffuser/Reflector and driver set complete in all respect. 15 Supply and fixing of LED Tube Light with batten suitable for up to 1X22 watt LED on surface complete in all respect. 16 Supply and fixing of Pendent mounting having IX4 size 36 to 46 Watt seamlessly Interateds LED luminiew with acrylic sheet diffuser and intergral electronic driver complete in all respects. 17 Supply of Ceiling Fan with motor of A.C. Permanent insulation capacitor rating confirming BEE 5 Star rating and IS:374/79 and also comply with IS:1709/1984 with latest amendment. The rated volage 220/240 volts, 50 Hz, 1-ph A.C.the fan assemble should consists of down rod blades, shackle canopies etc and with double ball bearing system. 18 BEE 5 Star rated-1200mm sweep 19 Supply & fixing of Call Bell Of Approved Make on matching polished MDFEG board brass including connection etc. as required. 20 Supply and burying of 600mm x 600 xómm G.I. plate, vertically for earthing with its top atleast 3 mts. below ground level complete with 20mm G.l.pipe and funnel for watering and two earthing leads No.8to10SWG G.I.wire in 15mm diaG.I. Pipe upto switch board (from apron to witch board the cost of G.I. pipe and G.l. wire will be extra) 30cm. square C.1. frame with hinged cover, masonary housing, termate layers/of charcoal/ coke and salt east 150mm thick alround etc. complete all respects. 21 Supplying & Laying of 25mmX3mm G.I. Strip from earth electrode in ground as required Complete in all respects. 22 Supply & fixing of two number 8 SWG G.I. wire for earthing purpose as required omplete in all respects. 23 Supply and fixing of 6 Amp to 32 Amp MCB (10 KA) C Curve 24 6-32 amps. Cat A 25 Supply and fixing of 40 Amp. 4 Pole MCB (10 KA) 26 Supply and fixing of 63 Amp 4 Pole MCB (10 KA) 27 supply and fixing of surface/flush mounting MOT TPA distribution board with aditional metal door without MCR lete in all respect, as directed at site by Engineer Incharge 28 Supply and fixing of surface/flush mounting way TPN distribution board with ditiona metal door without MCB mplete in all respect, as directed at site by Engineer Incharge 29 Supply & fixing of Crimping, solder, less, tob electroplated lugs of lewemall make suitable for 1.5 sqmm to 6 sqmm cables, including tapping with tape. etc complete in all respect. 30 Supply and fixing of single pole MCB including plate 31 Supply and fixing of power plug with V fiusb type modular switch and 5 4/250 Volt flush type universal socket switch on concealed M.S Routing supply of all material, labout Frerequited for proper completion 32 Supply and fixing of Sheet Steel Enclosure, Max Plust Mounting fitted With 20/12 Pn and earth metal clad scraping plup and socket complete in all sas per direction and satisfaction of er-in-charge 33 Erection and testing of ceiling fan and regulator for room height upto 3.5 mts. Including supply of 3 mm. thick G.I. down rod 19 mm dia duly painted, completein all respects 34 Erection and testing exhaust hole with suitable size of rag bolts nuts and washers etc. complete in all respects 35 Supply and fixing hexagonal/Round G.P. Fan box of approved make made up of 1.0 min thick ISI marked G.P. Sheet spot welded four to Eight holes of 25 4mm for pipe entry of the box Holes should be semi-shuttered type with 0.5ram G.P. Sheet made upper & lower cover duly screwed fitted with 300mm round zink coated M.S. Bar x 12mm & brand name should be embossed. Fixing with wiring conduit laid in the R.C.C. roof helare concreting alongwith supply of all material labour. T & P etc required for proper completion of the work. 36 Supply fixing of electronic fan regulator Modular) 120-280 V. ISI marked, on the ensting switch board including making netbion required material, labour T/P etc proper completion of work to the satisfaction of Engineer in charge of work. 37 Supply & laying of aluminium conducter, PVC insulated armoured, served, sheeted cable 1000 bolts grade at a depth of 750mm oriow ground level over a cushion of 75mm thide satid alround and protected with bricks on sides and top on surface, the run shall be fixed on M.S. clamps etc. suitable size or as directed by the teer-Incharge, complete in all respect. armourning of the cable shall be properly ected with the earth conductor by clamps etc 38 6 sqmm. 2 core 39 10 sqmm. 2 core 40 6 sqmm. 4 core 41 50 sqmm. 3.5 core 42 Supply and fixing of brass nickle plated impression gland for PVC insulated & ured served sheathed, underground e including rubber ring etc. respects. The armouring of the cable be properly complete in earth 43 6 sqmm. 2 core 44 10 sqmm. 2 core 45 6 sqmm. 4 core 46 50 sqmm. 3.5 core 47 Supply and fixing of copper thin platted cables sockets (lugs) to the cable leasds. With tape and making of connections of etc complete in all as per direction of e-i-c. 48 6 Sq.mm 49 10 Sq.mm 50 50 Sq.mm 51 Supply & Errection of factory fabricated & wired metal lad dust and vermin pevol The mounting MS Channel Base with boom and top cable entreis Electrical el panel with TPN MCCBs (Four Pole KA with thermal magnatic releasel hes complete and instrument chamber complete in all respects. The instrument chamber shall be separate and shall mmprise of flush type digital metering stem for phase to phase voltage and ungle phase voltage current and other parameters (KVA, P.F. KW etc) in each phase with touch type selector switches for dillerent readings, instrument fuses, current mansformer ecc. The panel board shall have table capacity electrolytic aluminium bars as per IS8623 or above istulated wheat shrink sleeving and mounted on hygroscopic supports such as BMC support with deteachable side vers and shall be suitable for extension on des The MCCBs shall be complete sustable cable end boxes, compression and indicating lamp on incoming etc jincludes the grounting of the board per directions of Engineer-in charge. All of 100 Amp and above shall have meter The panel board shall be ted with CRCA sheet with a minimum fabricated with CRCA sheet with a minimum thickness of 1.6 mm/2 mm. Cubicle type switch board shall be of cat A & B only. 52 The minimum clearances between bus bats be as follows 53 Phase to phase minimum 20mm 54 Phase to neutral-minimum 15mm 55 CUBICAL PANEL BOARD (MCCB TYPE) 56 L.T. PANEL 57 Incoming: 58 one (1) No. 200 Amp. MCCB-1 No. 59 Metering: 60 One (1) No. (0-500V) 96X96 Sqmm voltmeter with control fuse & selector switch. 61 One (1) No. (0-200A) 96X96 Sqmm CT operated Ammeter with selector swithc, CTs etc. 62 One (1) Set of Phase Indication Lamp. 63 Bus Bar: 64 One (1) No. 209A, TPN aluminium bus bar of suitable length. 65 Outgoing: 66 Phase in dication lamps on each outgoing to be provided. 67 100 Amp. MCCB-1 No. 68 63 Amp. MCCB - 3 No. 69 OR outgoing as per site requirement (AS/SLD) 70 Supply and fixing of danger board fabricated from 10 gauge M.S. sheet as per I.E. rules. 71 Supply and laying of 1800 mm X 900 mm X 12 mm thick chequred rubber matting of tested quality. 72 Supply and erection of steel tubular pole 7.5 meters long designated 410 SP-6 in 1:3:6 cement concrete foundation including excavation, back filling etc. complete in all respect. 73 Supply and fixing of service bracket of 50 mm. dia 4 meter long fabricated from class B G.I. pipe complete with two bend, socket, wall clamps. 7/3.15 mm. G.I. stay wire, stay insulators etc. complete in all respect. 74 Painting of the pole with 2 coats of aluminium paint over red oxide primer complete in all respect. 75 Supply and fixing of LED street light fitting having diecast aluminium body and diffuser/reflector with driver set suitable for 75 watt to 90 watt confirming to IP 65 protection complete in all respect. CAT AAA 76 Supply & wiring of submains with two number 25 sq.mm FRLSH PVC insulated 1100 V grade single core multistrand opper conductor cable in 20mm dia heavy do: (2mm thick) PVC conduit with 1 Number 15 sq.mm. FRLSH PVC insulated 1100 V grade multistrand copper conductor cable as earth continuity wire drawn inside the conduit complete in all respect 77 Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid pool paint consisting of time switch TSO 100 series with contractors. HRC fuses. solating switch metering instrument & ment box with CTs etc. in case of TPN complete in all respect. 78 25A SPN 79 Supply and fixing200 Amp 415V heavy duty double break HRC fuse type metal clad TPN complete with HRC fuse etc.on angle iron rame complete in all respects. 80 Supplying and drawing following pair 0.5 FRLS PVC insulated annealed copper onductor unarmoured telephone cable in existing surface/recessed steel/PVC our as required. 81 Supplying and drawing co-axial TV cable RG grated 07 mm solid copper conductor PE ated shielded with fine tinned copper ad and protected with PVC sheath in the surface/ recessed steel/ PVC at required 82 Supplying and fixing following modular switch/socket on the existing modular & switch box including connections including modular plate etc as required 83 Telephone socket outlet 84 TV antenna socket outlet 85 Supplying and fixing metal box of following (nomina size) on surface or in recess with suitable size of phenolic laminated heet cover in front including painting etc as equired. 86 5mm x 75mm X 60mm Deep 87 Supplying and fixing following size/modules, Gl box along with modular ase & cover plate for modular switches in cess etc as required. 88 or 2 Module (75mm X 75 mm) 89 Supplying and fixing the louvers / shutters complete with frame for exhaust fans of all required 90 Supplying and fixing modular blanking ate on the existing modular plate & itch box excluding modular plate as required 91 Providing, laying and fixing following dia pipe (medium class) in ground complete G.I. fittings including trenching (75 cm) and refilling etc as required. 92 100 mm sweep. 93 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required WC pan with ISI marked white plastic seat and lid 94 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat lid 10 litre low level white P.V.C. flushing cistren including flush pipe with manually controlled device (handle lever) confirming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required 95 W.C. pan with ISI marked white plastic sead and lid 96 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require 97 White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap. 98 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless stell plug 40 mm. including painting of fittings and brackets, cutting and making good the walls wherever required 99 Kitchen sink with drain board 100 510X1040X200 mm 101 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. 102 Semi rigid pipe 103 a) 32mm dia 104 b) 40mm dia 105 Providing and fixing 600X450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 106 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430X260X350 mm and 340X410X265 mm sizes respectively with automatic flushing cistern with standard flush pipe and CP brass painting of fitting and brackets, cutting and making good the walls and floors wherever required 107 a) one urinal basin with 5 litre white P.V.C. automatic flushing cistern 108 b) Range of two urinal with 5 litre white P.V.C. automatic flushing cistern 109 c) Range of three urinal basins with 10 litre white P.V.C. automatic flushing cistern 110 Providing and fixing thick fixed in Urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grount or with cement concreate 1:2:4 (1 cement 2 coarse sand: 4 graded stone) aggregate (6 mm nominal size) as per direction of Engineer-in-charge and finished smooth 111 Granite stone of approved shad 112 Providing and fixing 8 mm dia C.P./S.S. jet with flexible tube upon 1 meter long with S.S. triangular plate for European type W.C. of quality and make as approved by engineer-in-charge15 mm nominal bore 113 Providing and fixing CP Brass 32 mm size Bottal Trap of approved quality & make and as per the direction of Engineer-in-charge 114 Providing and fixing Toilet paper holder 115 a) CP brass 116 Providing and fixing PTMT Liquid soap container 109 mm wide 125 mm high and 112 mm distance from wall of standard shape with bracket of the same material with snap fitting of approved quality and colour weighing not less thatn 105 gms. 117 Providing & fixin 32 # G.I. Pipes spout including cutting & making good the walls etc. 118 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes. 119 a) 110mm diameter 120 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete. 121 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 122 a) 110mm 123 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 124 Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design. 125 Supply and fixing of UPVC S.W.R. pipe type-B confirming to IS-13592 including jointing the pipes with rubber ring,lubricant and UPVC SWR cupler confirming to IS-14735. Also including excavation of treanches cutting of walls and holes and repairing the walls,floors and refilling the trenches as before but excluding supply and cost of other fIttlings such as elbow,bend,tee and y-tee including supply of al marerial labour and T&P.Required for proper completion of work. 126 75 mm O.D. 127 110 mm O.D. 128 Supply and fixing of UPVC S.W.R. pipe nahni trap size 100x75,110/90 mm confirming to IS-14735 self cleaning design fixed in PCC 1:2:4 and supply and fixing of 125 mm dia heavy duty CP brass jali. 129 Supply and fixing of UPVC S.W.R. plain bend confirming to IS-14735. 130 Size 75 mm 131 Size 110 mm 132 Supply and fixing of UPVC S.W.R. plain tee confirming to IS-14735. 133 Size 75/90 mm 134 Size 110 mm 135 Supply and fixing of UPVC S.W.R. plain tee confirming to IS-14735. 136 Size 75x75x75 mm 137 Size 110x110x110 mm 138 Supply and fixing of UPVC S.W.R. plain Y confirming to IS-14735. 139 Size 75 mm 140 Size 110 mm 141 Providing & fixing G.I. pipes complete with G.I. fittings & clamps including cutting & making good the walls etc. 142 (internal work) 143 Exposed on wall 144 20mm dia nominal bore 145 Painting G.I. pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality. 146 25mm dia nominal bore. 147 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 148 (internal work) 149 25mm dia nominal outer dia pipes 150 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. 151 15mm dia nominal outer dia pipes 152 20mm dia nominal outer dia pipes 153 25mm dia nominal outer dia pipes 154 Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 a) 15mm nominal bore 155 Providing & fixing CP brass bib cock of approved quality conforming to IS standards and weighining not less than 690 gms. 156 a) 15mm nominal bore 157 Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931 158 a) 15mm nominal bore 159 Providing & fixing C.P. brass extension nipple of approved make and quality as per direction of enginner-in-charge 160 Providing and fixing gun metal gate valve with wheel of approved quality. 161 20 mm dia nominal bore 162 25mm dia nominal bore 163 Providing and fixing high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet & over flow pipes. The base support i/c fittings & fixtures for tank shall be paid separately. 164 Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m.including getting out the excavated soil & then returning the soil as required, 165 in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. 166 Pipes, cables etc. exceeding 80mm dia. But not exceeding 300 mm dia. 167 Providing, laying and joining glazed stone ware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. 168 150mm diameter 169 150mm diameter 170 Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design. 171 150mm diameterS.W. Pipe 172 150mm diameterS.W. Pipe 173 Providing and fixing square mouth S.W. Gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 Kg and frame to be not less than 2.70 Kg as per standard design 174 150 x 100 mm. size P type 175 With bricks M-150 176 Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design 177 Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). 178 With bricks of class designation 75 179 length of main hold size 90X80 cm 180 MS foot including fixing in mainholes with 20X20X10concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded) 20 nominal size as per standard design 181 Supply and fixing gun metal non return valve of approved quality 182 Supply and fixing G.I. pipes complete with G.I. fitting including refilling etc. 183 nominal bore 184 nominal bore 185 Supply and fixing sand of grading zone V or coaser grade alround the external work 186 25 meter pipe 187 45 meter pipe 188 Supply and fixing gate valve (with cap complete with bolts, nuts etc.) 189 nominal bore 190 nominal bore 191 Mansory chamber 30X30X50 cm, inside with 75 class brick work in cement mortar 1:4 (1 cement : 4 coarse sand with CI surface box 100X100X75mm (inside) with fixed cement concreate slab 1:2:4 mixnecessary foundation concrete 1:5:10 and inside plastering 12 mm thick a floating coat of neat cement complete as per standard design 192 With F.P.S. bricks 193 Supply and fixing G.I. distribution branch with G.I. main of fixing tee, including cutting and complete 194 nomnal bore 195 nomnal bore
BRR : 9752066
Tender For Erection of various Electrical/Civil works from contractors/ manufacturer registered with UPRNN.- 1 VARIABLE REFRIGERANT FLOW SYSTEM (OUTDOOR UNITS) ; MAKE : Carrier / Toshiba / Daikin / Samsung / LG / Blue Star / Voltas 2 Supplying, Installation, Testing & Commissioning of Modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling/heating having 100% hermetically sealed inverter type twin Rotary/Scroll Compressor(s), minimum two compressors (with individual separate PCB) for above 14HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R-410-A Refrigerant or equivalent, vibration Isolators with suitable foundation etc. complete as required. To have better efficiency condenser fan shall be capable to operate at different speed with respect to load. The unit shall deliver the rated capacity and in confirmation as per IS 18728:2024 and CPWD Specifications and work even at 50°C ambient temperature without tripping. The system shall be able to deliver 100% of the rated capacity upto 39 0C. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply and BMS compatible. The unit shall be filled with first charge of the refrigerant and ready for use as required. The condenser should be coated with a hydrophilic film to prevent water accumulation on the surface of the heat exchanger, enhance water dispersion, and reduce the risk of degradation, thereby improving overall performance and durability. The Indian Seasonal Energy Efficiency Ratio (ISEER) of the unit shall be as per Energy Conservation and Sustainable Building Code (ECSBC) 2024 as below and complete as per CPWD specification, connections, inter connections etc. as required. (For capacity <40 kWr ISEER 5.4, Capacity > 40 and <70 ISEER 5.5, Capacity > 70 ISEER 5.6 for ECSBC Building) For Cooling or Heating or Both 3 14 HP to 22 HP 4 INDOOR UNIT 5 Supplying, Installation, Testing and Commissioning of following minimum capacity 4 way Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration Isolation, Corded remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The Indoor units must shut down upon receiving a singal from the BMS System/Fire Singnals. The system shall be capable to adjust air flow as per room requirement in auto mode. The cooling capacity of indoor unit will be at air inlet conditions of 27 0C DB and 19 0C WB emperature. (Make will be same as of Outdoor) 6 1.2 TR 7 1.6 TR 8 2.0 TR 9 2.6 TR 10 3.6 TR 11 4.1 TR 12 High wall type Indoor unit 13 Supplying, Installation, Testing and Commissioning of following minimum capacity High wall type Indoor unit equipped with and comfort washable synthetic media prefilter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cord less remote control, drain pan, necessary accessories etc., suitable for operation on 230 V ± 10%, 50 Hz, single phase AC supply, complete as required. The Indoor units must shut down upon receiving a singal from the BMS System/Fire Singnals. The system shall be capable to adjust air flow as per room requirement automatically. The cooling capacity of indoor unit will be at air inlet conditions of 27 0C DB and 19 0C WB temperature. (Make will be same as of Outdoor) 14 2.0 TR 15 Supplying, Installation, Testing and Commissioning of following minimum capacity and external static pressure VRF/VRV ceiling mounted mid high static ductable type Indoor unit equipped with washable synthetic media prefilter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, corded remote control, outer cabinet, vibration Isolators, drain pan, drain pump, other necessary supports etc., suitable for operation on single phase AC supply 230 V ± 10%, 50 Hz complete as required. The Indoor units must shut down upon receiving a singal from the BMS System/Fire Singnals. The system shall be capable to adjust air flow as per room requirement automatically. The cooling capacity of indoor unit will be at air inlet conditions of 27 0C DB and 19 0C WB temperature. (Make will be same as of Outdoor) High Static Ductable units (minimum 49 to 77 pascal external static pressure) 16 3.2 TR 17 4.6 TR 18 Supplying, Installation, Testing and Commissioning of following minimum capacity and external static pressure VRF/VRV ceiling mounted high ductable type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, corded remote control, outer cabinet, vibration Isolators, drain pan, drain pump, other necessary supports etc., suitable for operation on single phase AC supply 230 V ± 10%, 50 Hz complete as required. The Indoor units must shut down upon receiving a singal from the BMS System/Fire Singnals. The cooling capacity of indoor unit will be at air inlet conditions of 27 0C DB and 19 0C WB temperature. (Make will be same as of Outdoor) 19 6.6 TR 20 8.0 TR 21 Supplying, Installation, Testing and Commissioning of Y/T/Multi Joints. Joints shall be of same Original Equipment Manufacturer (OEM) make as of ODUs and IDUs 22 Indoor Units 23 Outdoor Multi Joint 24 COPPER REFRIGERANT PIPING 25 Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 26 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm 27 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm 28 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm 29 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm 30 19 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm 31 22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm 32 25.4 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm 33 28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm 34 31.8 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm 35 34.9 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm 36 38.1 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm 37 41.27 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm 38 DUCTING, GRILLS,DIFFUSER AND INSULATION 39 Supplying, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/ round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, bends, transitions, reducers, end caps, collars etc as required complete in all respect in confirmation with IS : 655 and approved drawings and specifications of following sheet thickness complete as required. 40 Thickness 0.63 mm sheet 41 Thickness 0.80 mm sheet 42 Thickness 1.00 mm sheet 43 Thickness 1.25 mm sheet 44 Supplying, Fixing, installation, testing and commissioning of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers in confirmation to SMACNA/IS and as per specifications complete etc. as required. 45 Supplying and fixing of following thickness duly laminated aluminium foil of mat finish closed cell Nitrile rubber (Class O) insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. 46 Supplying and installaton following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers MS/GI Suspenders i/c base of suitable size MS/GI angle, bolts & nuts, painting suspenders, fastener etc as required. 47 100 mm width X 50 mm depth X 1.6 mm thickness 48 300 mm width X 50 mm depth X 1.6 mm thickness 49 600 mm width X 62.5 mm depth X 2.0 mm thickness 50 Supplying and laying 6 SWG G.I. wire at 0.50 Meter below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. 51 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 52 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. 53 Upto 35 sq. mm (clamped with 1mm thick saddle) 54 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) 55 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. 56 Upto 35 sq. mm (clamped with 1mm thick saddle) 57 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) 58 Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) 59 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 60 4 X 10 sq. mm (25mm) 61 3½ X 120 sq. mm (45mm) 62 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 63 Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: Asbestos Cement sheet 64 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, will be paid in this account).ral frame work from the gantry, fixing and erecting the same in position all complete as per drawings, specification and direction of the engineer in- charge.(Structural frame work including M.S. plate to be provided separately. Rectangular area of the sheet only shall be measured for payment). Overhead informatory road signageomplete for all heights as per specifications, drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.excluding the cost of painting with :12.5 mm thick tapered edge gypsum plain board conforming to IS: 65 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15- 18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross “T” of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “T” at 600 mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27 x 37x 25 x1.6 mm fixed to ceiling with12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. 66 Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of Engineer-In- Charge. With cement mortar 1:4 (1 cement : 4 fine sand) 67 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 68 Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) 69 Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture 70 Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar 71 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm 72 Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge. 73 Lime, moorum, building rubbish 74 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. :Internal work - Exposed on wall 75 20 mm nominal outer dia .Pipes. 76 25 mm nominal outer dia .Pipes. 77 32 mm nominal outer dia .Pipes. 78 MR Items 79 VARIABLE REFRIGERANT FLOW SYSTEM (Indoor UNITS) ; MAKE : Carrier / Daikin / Samsung / LG / Blue Star / Toshiba / Voltas 80 Supply installation, testing and Commission of Heat Pump Type variable refrigerant flow modular type air conditioning system suitable for both heating and cooling with hermatically sealed Inverter driven type Scroll Compressors ,with electronic controls & Remote as applicable. The units should be suitable for 415 ±10% V for outdoor unit including fully charged with refrigerant R410A to outdoor unit and all running refrigerant pipe as per detail given in specifications & drawings for the following configurations. It shall include anti vibration isolator pad for outdoors unit.The unit shall deliver the rated capacity at AHRI Conditions and work even at 55°C ambient temperature without tripping. The interconnecting copper pipes of outdoor units should be provided with anti-corrosive coatings and condenser coils with anti corrosive blue fins. The cost of loading, Unloading at site , shifting to locations and interconnecting ODUs joints , shall be included. Rates 81 24 / 26 HP 82 Floor Standind Ductable Type Indoor Unit 83 14.40 TR 84 Supply installation testing and comission of double skin sheet metal sectionalised construction treated fresh air units double skin panels with 46mm thick injected PUF of density not less than 40kg/ cum with thermal break profile The treated fresh air units shall be complete with pre- filter (MERV-8) 300mm thick fine filters IMERV-13) multi row deep DX cooling coil of copper tube and aluminium fin construction (with 100mm gap between two sets of three rows deep cooling coils) forward curved DIDW centrifugal fan belt drive package insulated SS auxiliary drain pan IE-02 squirrel cage induction motor all complete as per the specifications: 85 5000 CFM 86 5500 CFM 87 9000 CFM 88 3000 CFM 89 Supply of TFA Power Panel 90 Wire Less Remote 91 AHU KIT -Supply, Installation, Testing and Commissioning of VRV Kits for AHUs having all controllers & Electonic Expansion Valve (EEV) and temperature set arrangment. It Shall have cut off arrangement after a particular set value of Supply air Temperature. Price should include all control cabling etc. 92 SITC of outdoor type Electrical Panel for Power ON and OFF 415 V with suitable Bus Bars, Lamps, Switches, MFM meter, 93 Incomer: 4P 315 / 400 Amp MCCB 94 Out Going: 4P 32 A / 40 A / 63 A MCB As Required 95 Supply of LT Cable 96 3.5 C X 120 SQ MM AL Cable (Main Panel to VRV/VRF Panel 2 Run Each) 97 4C X 16 SQ MM Cu Cable 98 4C X 10 SQ MM Cu Cable 99 2C X 1.5 SQ MM Shilded Communication Cable 100 Installation Testing and Commissioning 101 Removing of old Out-door units & Installation of newOutdoor Units 102 Removing of All System 103 Core Cutting 100-200 MM 104 Buyback Value 105 Buyback of Removed Material of Existing VRV/VRF out doors, Indoors, Cable Tray, Cables, etc. Please Enable Macros to View BoQ information
Disclaimer
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tender Detail
| Website | http://eprocure.gov.in |
| Quantity | |
| MSME Exemption | No |
| Tender Type | Open Tender |
| Startup Exemption | Click Here |
| Competitive Bidding | NCB |
TENDER INSIGHTS
858
Electric TendersLive
Tell us about your Product / Services,
We will Find Tenders for you