(L1) 6515.37887 Spirometer, Specification: The Equipment Must Present: Operating System Compatible With Windows 7, 8, 8.1, 32 And 64 Bits Platforms Also 32 And 64 Bits Professional, Xp And Ultimate, Internet Or Local Network Connectivity (Hl7 Protocol), Pc Connection (Laptop Or Desktop) Via Usb, Electrical Supply, Supply, Metallic Hive Pneumotacographer (Brass Fleisch), Incentive Screens, Units. Measurement: Unit, (L2) 6515.85829 Spirometer, Use: Hospital, Additional Characteristics: Other Information According To Process Reference And/Or Descriptive, (L3) 6516.91858-Powerbreathe, Type: K5, Use: Physiotherapy, (L4) 6514.97395 Anatomical Nozzle, Have 9 (Nine) Levels Of Adjustable Loads, From 10Cmh2o To 170Cmh2o, With Pvc Nozzle Or Similar, Without Latex, Silicone Rubber Valve, Main Body, Lower Chamber, Lid, Load Adjustment And Nose Spring Button, (L5) 6514.97394-Respiratory Training, 10Cmh2o A 250Cmh2o, 07/24/2025, (L6) 6516.86980-Manovacuaceomer, Type: Digital, (L7) 6515.12895-Pulmonary Ventilate, Microprocessed Electronic Ventilate For Pediatric Neonatal Patients And Adults To Mobbi Obesity, Suitable For Intensive Care, With At Least The Following. Ventilation Modes: Vocted Volume Ventilation (Assisted / Controlled, Simv); Pcv Controlled Pressure Ventilation (Assisted / Controlled, Simv); Controlled Pressure Ventilation, Bipap Or Bi-Physical, Which Allows Spontaneous Ventilation (Active Expiratory Valve); Non -Invasive Ventilation - Niv; Ventilation In Invasive And Noninvasive Cpap, Psv Ventilation With The Possibility Of Supporting Support Cycling Of The Support Pressure, Parameters: Fi2 From 21 To 100%; Middle Volume Should Enable Adjustment From 10 Ml To At Least 2000Ml; Respiratory Rate From 5 To 150 Rpm; Inspiratory Time From 0, 2 To 5 Seconds At Least; 5 To 70% Supporting Pressure Cycling Of Inspiratory Flow Peak; Inspiratory Pressure From 5 To 80 Cmh2o. Support Pressure From 5 To 70Cmh2o At Least. These Pressure Values Cannot Be Considered With Peep, Ie They Must Be Considered Individually; Peep From 0 To 50 Cmh2o At Least; Have Inspiratory Sensitivity By Flow And/Or Pressure Sensitivity; Have Adjustable Rise Time (Rise Time) Or Inspiratory Time Control On All Pressure -Controlled Modalities; Monitoring System: At Least 12 ”Colored Screen With Touch -To -Touch Drive For Ease Of Operation And Possibility Of Slope, Rotational Button For Selection, Adjustment And Confirmation Of The Parameters. Presentation Of Curves Pressure X Time, Flow X Time, Volume X Time And Loops Pressure X Volume (Presentation Of At Least Three Curves Simultaneously In Real Time); The Equipment Must Have Numerical Values Of The Main Ventilatory Parameters; The Equipment Will Not Be Able To Monitor Any Parameter Through Proximal Sensors To The Patient (In Y), Except For Neonatal Patients, Where The Equipment Can Work With This Tip, (L8) 6515.60547-Cough Stimulation And Bronchial Hygiene Stimulation